DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition October 2013 OPTOTRONIC LINEAR (non-isolated) Approval marks in July 2013 OTi DALI 90/220-240V/1A0 LT2 L (SMART Interface) EPBD European Building Directive STAND-BY < 0.3W Fit for SMART Grid Diversity. Quality. Efficiency. Driver product features Supply voltage: 198-264 V (AC) / 176-276 V (DC) Output Data: 54-240 V / 250-1000 mA / 1.5-90 W Line frequency: 0 Hz, Pulsating DC, 50 - 60 Hz Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100 Dimming range: 1 to 100 % luminous flux (Combi PWM / Linear Dimming) Energy efficiency > 92 % (Full Load) / > 90 % (Half Load) Lifetime up to 100,000 hours and more (Tc – 10 °C) Suitable for luminaires of protection class I Suitable for New OSRAM SELV and NON-SELV (SLIM) Modules Smooth Dimming behaviour Effective Overtemperature Protection of the dimmable System (Intelligent Thermomanagement of the Driver) Very low Stand-By consumption < 0.3 W Tc = +75 °C (max.) Max. cable cross section for plug contact*: “s”: 0.5...1.5 mm² / “f”: 0.75...1.5 mm² Easy. Flexible. FIT. * “s“ = “solid“ = Single-wire conductor, “f“ = Multi-wire conductor DALI product features Compliance with the DALI standard to IEC 62386 latest Edition 2012 DALI Control Input protected against overvoltage and polarity reversal Touch DIM® and Touch DIM® Sensor function: Manual dimming (Touch DIM®) without any controller and with standard switches, incl. memory function (double click) and soft start (Last Switch-On Level) Approbations (in July 2013) Safety: to EN 61347-1, 61347-2-3, 61347-2-13, 62384 Lamp operation: to EN 60929 DALI standard: to IEC 62386 – 101, 102, 207 RFI requirements: to EN 55015: 2007+A1:2007 (300 MHz compliance)/CDN Line harmonics: to EN 61000-3-2 Immunity: to EN 61547 EL (Emergency Lighting): to IEC 61347-2-3 / App. J Emergency Installation: to EN 60598-2-22 Suited for Central Battery Systems: to EN 50172 SELV / NON-SELV System FIT o Operation Area for SELV-/NON-SELV Modules (Combination of Serial/Parallel Module Connection) Corridor Functionality on 3 Dimming Level Basis o Triggered via Commodity Relay PresenceSensor or Push Button for 220-240V o NO DALI Controls needed TouchDIM RELEASE o Auto Switch-Off @ sufficient Light Levels o Optimized Synchronity of DALI participants in one control loop o Suitable for Pulsating DC Input No limitations in length of control loops SMART Interface Driver/Module: Auto Current Set Easy FIT for Emergency o Automatic DC detection (0 Hz, Pulsating DC (50/60 Hz), On/Off switchable) o Configurable emergency power characteristics (1…100 % Lum. Flux / DEFAULT: 15% Arc. Power); o Locking Functionality of DALI parameters for Higher Safety (Read Only Mode) o Re-Installation of AC Level/Conditions before DC operation (Auto AC/DC) Constant Lumen Output (CLO) / Flex. Current Setting o Compensation of Lm-Degeneration over Module Lifetime o Pre-Set CLO Functionalities o Current Setting for highest Module-Variety Power2Module Technology o Power Boost Mode for Higher LmPackages on demand / CLO via Flexible Flag Setting Smart Monitoring & Management o Feedback of Power Consumption (High Range/Resolution) o Feedback of Detected Module & Module Operation Counter (Resettable) o Overvoltage Monitoring (Detection of up to 3 sep. OV events) Switching b/w Linear/Logarithmic Dimming Curve for Daylight Simulations / Special Effects Memory Bank Usage: Public Information Management w/ Internet XML description GREY: Available > 2014 Misprints and technical changes excepted DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 Technical Specification Input (Mains) Specification Nominal Voltage Nominal Frequency Max. allowed cable capacitance Any Lead to Ground Ballast to Ballast (all leads) Mounting Screws 220-240 V 0 / 50…60 Hz / Pulsating DC 176 V 198-264 V 198 V 176-276 V 350 V (AC) Min. AC Voltage for Starting AC Operation on Min. DC Voltage for Starting DC Operation on Max. allowed Input Voltage (2h) Output (LED Module) Specification Rated Output Operating Voltage Rated Output Operating Current Max. Output Voltage (w/ Open Circuit) Output Current Accuracy Max. Output Current Ripple Total Harmonic Distortion (THD) Max. allowed cable length (SUM all Modules) Leakage Current / ECG Efficiency / Stand-By Power Energy efficiency 100 pF 5 pF M4 max. 54-240 V 250 – 1000 mA <250 V DC ±5 % <10 % (@ 100 Hz) <10 % 2m <0.5 mA No Load Power (EuP 2009/125/EC – r) Stand-By Power (AC + DC Mode) Power Factor (@ Pmax.) Dimming Interface Dimming Range Way of Dimming: Smart Combination (PWM < 250 mA / Linear Dimming ≥ 250 mA) Constant Lumen Output (CLO) Starting Time Temperature / Lifetime Conditions Ambient Temperature Range Max. allowed Tc - Temperature Ballast Lifetime Advanced Lifetime 50.000 100.000 Tc = +75 °C Tc = +65 °C Protection Class Push In Terminals (Wago 250) Max. cable cross section for plug contact* > 92 % (Full Load) > 90 % (Half Load) < 0.5 W < 0.3 W > 0.95 1…100 %, DALI PWM (463 Hz) / Linear Dimming 70…100 % settable < 0.3 s -25…+50 °C +75 °C Failure Rate <10 % IP 20 “s”: 0.5...1.5 mm² “f”: 0.75...1.5 mm² * “s“ = “solid“ = Singlewire conductor, “f“ = Multi-wire conductor Inrush Current / Max. ECG per Circuit Breaker (unipolar version) typ. /∆ ( 230 , network impedance 1Ώ) 53 A / 200 µs / 22 µF Cap. CB Type B C 10 A 8 13 16 A 13 22 20 A 16 27 25 A 20 34 Tab. 1: Driver`s Technical Specification 2 Misprints and technical changes excepted DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 Operation Areas: Combinations w/ OSRAM NON-SELV/SELV Modules 630/1000/2000 lm OTi DALI 90/220-240V/1A0 LT2 L V/I-Output Characteristic incl. LEP Non-SELV 250 225 5P-2S 200 LEP Non-SELV: 630lm: green 1000lm: cyan 2000lm: orange 4P-2S 3P-2S 175 2P-2S Vout [V] 150 125 5P-1S 6P-1S 100 4P-1S 3P-1S 75 2P-1S 6P-1S 8P-1S 5P-1S 7P-1S 8P-1S 3P-1S 9P-1S 10P-1S 4P-1S 5P-1S 50 25 0 0 100 200 300 400 500 600 700 800 900 1000 1100 Iout [mA] Fig. 1: Different Lm-Packages w/ NON-SELV Module Combinations (Example w/ Luminous Color 830) P: Parallel / S: Serial Wirings OTi DALI 90/220-240V/1A0 LT2 L V/I-Output Characteristic incl. LEP SELV 250 225 LEP SELV: 650lm: bright green 1100lm: dark blue 2000lm: magenta 200 2P-5S 175 1P-5S 2P-4S Vout [V] 150 2P-5S 1P-4S 125 2P-4S 2P-3S 100 1P-3S 2P-3S 2P-2S 75 1P-2S 2P-2S 4P-2S 2P-2S 3P-2S 50 25 0 0 100 200 300 400 500 600 700 800 900 1000 1100 Iout [mA] Fig. 2: Different Lm-Packages w/ SELV Module Combinations (Example w/ Luminous Color 830) P: Parallel / S: Serial Wirings 3 Misprints and technical changes excepted DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 DALI (GII): Corridor Function & Parametrization Possibilities a) Description The Corridor Function is a Driver`s Automatic Dimming Functionality of ALL OSRAM DALI (GII) ECGs having the Corridor Function Symbol on their Rate Stamp. Switching the mains voltage (220-240V, 50/60Hz) on the DALI Inputs (DA, DA) of the ballasts via commercial Relay Presence detectors (or Staircase Automates) triggers the Automatic Corridor Dimming behaviour. This solution is used for cost-effective Energy Saving installations in Floors, Staircases, Storage Halls etc. w/o add. Light Management Peripheries. OSRAM DALI (GII) drivers being in Corridor Mode are synchronized via the mains frequency (50/60 Hz) to guarantee SAME operation behaviour when controlled by the SAME sensor – the number of participants in one Corridor Mode control loop is only limited by the Sum of participants` Inrush Currents allowed per Phase. Fig. 3: Wiring diagram of OSRAM DALI (GII) drivers, being in Corridor Operation Mode b) Entering/Leaving the Corridor Mode The Corridor Mode can be entered (from DALI or TouchDIM Mode) by providing a 220-240V/50,60Hz Signal on driver`s DALI input for longer than 120 (50 Hz), 100 (60 Hz) seconds, permanent. Defined change-over from Corridor Mode to TouchDIM Mode by 5 single short push events (Push Button, switching mains 220-240V/50,60Hz) w/in 3 seconds. c) Parametrization of Corridor Function The 3-Levels Corridor Function can be easy set via DALI magic/wizard System (see also DALI wizard manual). The settings (Light Levels (A, B, C), Delay- & Stand-By Times (D0, T1, T2), Fade Down Times (F1, F2)) are stored in the ballast - no intelligent external peripheries are needed. Light Value A Fig. 4: 3 Dimming levels (1….100%) Free parameterization (I…VI) via DALI magic Stand-By I B Stand-By II C I II III D0 F1 IV T1 V F2 VI T2 Time DEFAULT Values: A: 100%, D0: 120s, F1: 32s B: 10%, T1: Endless C: OFF 230V ON OFF 4 Misprints and technical changes excepted DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 DALI (GII): TouchDIM® Function & Parametrization Possibilities a) Description The Standard TouchDIM® Function is used to ALL OSRAM DALI drivers – pls. refer to OSRAM Application Notes / Installation hints for detailed description. OSRAM DALI (GII) ECGs offer extended TouchDIM® features as follows: Flexible Setting of TouchDIM® parameters via DALI magic/wizard system Automatic LED Modules` Switch-Off at sufficient light level (Controlled via Light- / Presence Detection Sensor) Additional Operation in Pulsating DC (i.e. via mains rectifying diode) for control loop lengths w/o limitations Optimized Synchronity of participants in SAME control loop (lowest asynchronity) b) Parametrization of TouchDIM® Function in OSRAM DALI (GII) drivers ALL OSRAM DALI (GII) ECGs allow the free setting of TouchDIM® parameters (i.e. min./max. Levels, Fade Up- & Down Times, Time Outs, Standby Times, Switch On Levels etc.) via DALI magic/wizard System (see also DALI wizard manual). Advanced Setting options allow the enabling/disabling of TouchDIM® specific control options (i.e. Short/Long Push, Double Push etc.) or the Automatic LED Modules` Switch-Off at sufficient light level. Light Value Fixed or Daylight Controlled TDmax I II III Fade Up Time Out DEFAULT Values: Fade Up Time: 0.7 s Fade Down Time: 32 s Time Out: 15 min. Standby Time: 5 s IV TDmin Fade Down Stand-By Fig. 5: TouchDIM® Functionality Free parameterization (I…IV) via DALI magic Time TouchDIM LS/PD Signal c) Automatic LED Modules` Switch-Off at sufficient light level Using TouchDIM® Functionality in Light- /Presence Detection Sensor Mode (LS/PD Signal), OSRAM drivers perform a regulation of luminous flux to guarantee constant light levels on working areas during presence. The correlation: The more natural light incidence, the less artificial light is necessary for getting constant light levels. Being already on Control Limits (min. Dimming Level (TD min.)), OSRAM DALI (GII) ballasts offer the possibility to Switch-Off Light (disable PIR signals of the TouchDim® Sensor) as long as the Light Sensor detects a Light Level which is above the set Threshold level (Default 25 Lux) for more than 1 min. (incl. 5 s Standby Time). A reduction of the natural light incidence causes a value drop below the Threshold Setpoint and reactivates the driver to guarantee constant light levels on working areas during presence (Enabling of PIR signals). Actual Level Deviation TD max. Fig. 6: TouchDIM® Automatic Switch-Off Concept for OSRAM DALI (GII) drivers TD min. OFF Threshold Setpoint 1 min. + Stabdby Time 5 Misprints and technical changes excepted DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 Pinning / Connection Diagrams: OTi DALI 90/220-240V/1A0 LT2 L Input Pinning Fig. 7 Output Pinning Fig. 8 Output Pinning w/ ECG Internal Through Wiring Lines 21/27 (21/22–26/27) max. 2 m whole length (incl. ALL Modules) SMART Module Interface: OTi DALI 90/220-240V/1A0 LT2 L a) General Description LEDSet2 is a 1-wire analogue interface (Pin 24 / in Fig. 8) designed for OPTOTRONIC constant-current LED drivers. The interface uses LEDaux (-) as reference Ground (PIN 25 or 27 for external Resistor Connection) and supports the following functionalities: Output current setting of the constant current LED driver (LED module self recognition) Handling of Parallel LED modules connection (Multiple parallel LED strings) Thermal protection of the LED module The output current can be set by a simple external resistor placed between the Driver`s PINs 24, 25 or by intelligent Modules themselves, supporting LEDSet2 . The interface is safe proof in case of broken connection of the control wire. b) LEDSet2 Connector Configuration PIN 21, (26) is the positive power line LED (+) to the LED load, RED coloured on the Driver. PIN 24 is the output of the internal constant voltage source LEDSet2 (O+), WHITE coloured. PIN 22, (27) is the power return line LED (-) from the LED load as well as the ground reference for the interface logic (signal ground), BLACK coloured. c) LEDSet2 characteristic The relation between Rset and the driver output current (Iout) is defined by the following equation: 1000 (1) Where Kv is a fixed voltage source of 5 V generated by the driver`s interface circuit and delivered by the control wire to the external resistor Rset used to set the desired LED operating current. Rset-Iout characteristic is shown in Fig. 9. The relation is valid for values of Iout w/in the current range 0.1–5 A. Fig. 9: LEDSet2 / Iout vs. Rset Characteristica 6 Misprints and technical changes excepted DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 Easy FIT for Emergency Installations a) Description OSRAM DALI (GII) ballasts are able to detect DC operation (Operation range: 176 – 276V (0Hz / Pulsating DC)) w/o add. DALI commands / System Failure Levels. Due to flexible Enabling/Disabling via DALI magic/wizard (see also DALI wizard manual), highest flexibility in ALL installations is guaranteed: Operation range: 176 – 276V (0Hz / Pulsating DC) Flexible enabling / disabling via DALI magic DC level has higher priority than system failure level DEFAULT DC Level of 15% Arc. Power Locking functionality of DALI communication SMART Thermomanagement when DC Level is applied FIT for IEC 60598-2-22 (LUMINAIRE in Emergency Installations) Auto re-installation of AClevel / conditions before DC operation w/o external controls EL approval marks (acc. IEC 61347-2-3) w/ EBLF, EMC, overvoltage, endurance test … Constant Lumen Output (CLO) / Flexible Current Setting a) Description OSRAM DALI (GII) ballasts support the Constant Lumen Output Setting (CLO) Functionality via DALI magic / OSRAM Optotronic Tool 2.0 (2.1). The user has the possibility to define own CLO profiles and to set min./max./nom. Currents for Module operations. ALL settings can be password protected – for detailed info pls. see 3DIM Tool Manual, page 18 - 24 (SW and manual downloadable under: http://www.osram.com/osram_com/tools-and-services/tools/dali-magic/index.jsp) OSRAM DALI magic/wizard: Diagnostics, Analysis & Parametrization of DALI Installations The ONE Parametrization-, Analysis- & Diagnostics Tool. Suited for ALL DALI ECGs BUT specialized for OSRAM DALI (GII) models. ONE System – ONE Solution – Highest Flexibility in Applications. Easy Diagnostics/Analysis/Parametrization of DALI Installations Fast Search of Failures in Adressing/Programming Easy Programming of OSRAM 3DIM ECG Dimensions [mm] 120 x 79 x 28 L=120 / B=79 / H=28 (DALI magic) NEW Corridor Functionality & TouchDIM Configuration Tool: GUI based setting of dimming levels + Fade Timing via Drag & Drop Emergency Package Tooling: Setting of Emergency Level (DC, AC), Locking Flag, DALI System Failure Level etc. Constant Lumen Output (CLO) / Power2Module Functionality: Compensation of Lm-Degeneration over Module Lifetime DALI magic EAN40 (1 pc.): 4008321582768 / Software Download: www.osram.com/lms-magic DALI magic: Wiring Topology DALI magic DALI ECG 300 m DALI ECG LMS Software: DALI ECG OR • DALI wizard Up to 64 ECGs within one DALI circut • 3DIM Tool 3DIM ECG USB 6 V DC power supply One ECG at a time L N Misprints and technical changes excepted 7 DALI (GII) Dimmable ECG for Current Sourced LED Modules Edition June 2013 Installation Instructions Radio interference suppression of dimmable SSL luminaires Operation of multiple drivers in a luminaire: General hints: Mains cables and control lines may be routed together and should be laid close to the luminaire wall Mains and control cables must not be laid close to the module cables If crossovers of mains and modul cables are unavoidable, they should cross perpendicularly Do not lay the PE conductor together with the module cables Do not use shielded module cables (reduction of capacity leakage currents) The OSRAM DALI ECG must always be installed near the module(s) so that the module cables can be kept short in the interests of good radio interference protection Lay the module cables close together and close to the module Module cables must not be laid in metal pipes and must not be shielded cables Guide the cables of the different module ends separately There should be a minimum spacing of 12 cm between the module circuits (module and cables) of different ECGs. If this is not possible, the module wiring must be carefully installed so coupling between the module circuits is reduced to a minimum: Lay the module cables close to the appropriate modules so that the area covered by the module circuit is as small as possible. The module circuits of the two ECGs must not overlap. This is particularly important for color control if adjacent ECGs are dimmed to different levels. There should be a spacing of several centimeters between the module cables of two ECGs Mains and control cables should not be laid close to the module cables (prevents undesired couplings into the control cable)All the mains and control cables may be routed together. To ensure that radio interference suppression is not impaired, there should be a gap of several centimeters to the module cables. Housing dimensions/article numbers OTi DALI 90/220-240V/1A0 LT2 L DALI Product description l b h l1 [mm] [mm] [mm] [mm] OTi DALI 90/220-240V/1A0 LT2 L 280 30 21 270 EAN10 1 pc. EAN40 20 pcs. 4008321867568 4008321867575 Manufacturer’s address: OSRAM GmbH Steinerne Furt 62 D-86167 Augsburg Germany www.osram.com Technical support: www.osram.de www.osram.com Kunden Service Center Germany +49 (0)89-6213-60 00 8 Misprints and technical changes excepted