Instruction Manual
DPG-Series Inclinometer
Instruction Manual
DPG-Series
Inclinometer
Version 1.1
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
1 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
Contents
1
History
3
2
2.1
2.2
General Information
Features
Type and order codes
3
3
3
3
3.1
General Information
Notice
3
4
4
4.1
General of the inclinometer system
Description of the liquid/conductive measurement principle
5
5
5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
Mechanics and Conditions
Mounting Instructions
Installation
Measurement
Mounting
Mechanical data
Dimensions
Label information
Cable and configuration
Connecting to a PC using an RS 232 interface
6
6
6
6
6
6
7
8
8
9
6
6.1
6.1.1
6.1.2
6.1.3
6.2
6.2.1
6.2.2
6.2.3
Interface
Digital Output RS232
Electrical Levels
Interface parameter for all NS–xx/DPG2–RUx (except NS–30/DPG2-RUN)
Interface parameter for NS–30/DPG2–RUN
Programming commands
Command Reference user level
Command Reference SETUP level
Step response/filtering NS-15/DPG2-RUG
10
10
10
10
10
11
11
12
13
7
7.1
7.2
7.3
Qualification Testing
Standards
Periodical Testing
Material Testing
14
14
14
14
8
8.1
Additional Information
Ordering Information
15
15
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
2 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
1
History
Ver.
Date
Purpose
Author
1.0
2013-01-28
Creation
M.Zürn
1.1
2015-07-07
Update Chapter 3.1 Point 7 & add. Minor changes
Update of Fig. 5.2, Dimensions & Weight
F.Schwieger
2
General Information
The NS-xx/DPG2-RUx is a µC controlled inclinometer for industrial applications. The NS-xx/DPG2
features a measuring range up to ± 30°.
2.1 Features
•
•
•
•
•
two inclination sensor cells based on a conductance measurement principle
electronic excitation and readout of the cell signal
digital linearization
temperature compensation
outputs RS232 & voltage
2.2 Type and order codes
Required type of product can be ordered by use of one of the following part numbers:
Type
Measurement angle
Output
Supply
Order number
NS-5/DPG2-RUD
+/- 5°
RS232, voltage
+7… 30 VDC
G-NSDPG2-003
NS-10/DPG2-RUG
+/-10°
RS232, voltage
+7… 30 VDC
G-NSDPG2-001
NS-15/DPG2-RUG
+/-15°
RS232,voltage
+7… 30 VDC
G-NSDPG2-002
NS-30/DPG2-RUN
+/-30°
RS232 ,voltage
+7 ... 30VDC
G-NSDPG2-005
3
General Information
Thank you for purchase of a DPG2-Series inclinometer from Measurement Specialties.
This manual offers information on the proper installation and operation. For further technical
information on the performance of the DPG2-Series inclinometer, please see the Specification,
DPG2-Series inclinometer
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
3 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
3.1 Notice
Please observe all proper safety rules and regulations for electrical devices
when installing this inclinometer. In addition, the following recommendations are
made.
1. Do not apply power to the inclinometer during installation.
2. Avoid applying any mechanical pressure or stress to the housing.
3. Do not operate an inclinometer beyond the maximum angular sensing range
or threshold. Irreparable damage may occur.
4. Do not exceed the maximum fastening torque for the mounting screws,
as the base plate may become warped and/or irreparably damaged.
5. Use detergents free of solvents or acid for cleaning of the housing.
6. Avoid direct solar radiation.
7. Recommended tightening torque of cable gland (3±0.5 Nm) should be
checked once in a year after purchase to secure IP class of sensor module.
8. Should the inclinometer fail to operate properly, consult this manual for
possible solutions. Do not attempt to open the inclinometer, as damage may
occur. For other troubleshooting measures, please contact our service team.
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
4 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
4
General function of the inclinometer system
4.1 Description of the liquid/conductive measurement principle
Platinum electrodes are deposited in pairs on the base of the sensor’s cell parallel to the sensitive
axis. The chamber is partially filled with an electrolytic liquid. When an alternating voltage is passed
between two electrodes, the electric current will create a dispersed field. By tilting the sensor and
thereby reducing the level of liquid, it is possible to confine this stray field. Because of the constant,
specific conductivity of the electrolytes a variance of resistance is formed in relation to the liquid level.
A basic differential principle will yield an angle of inclination from the polarity signs.
Ceramic housing
Ceramic base plate
with electrodes
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
5 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
5
Mechanics and Conditions
5.1 Mounting Instructions
The inclinometer is designed for horizontal mounting, meaning the base plate of the inclinometer with
the three mounting holes needs to be placed on the horizontal plane of the object to be measured.
The mounting surface must be smooth and free of dust and grease. Fasten inclinometer to the surface
to be measured with three M4 screws, and use recommended tightening torque (depends on property
class of chosen screws, e.g. 2.9 Nm if M4 8.8 class screws are used with dry threads).
5.2 Installation
Prior to installation, please check for all connection and mounting instructions to be complied with.
Please also observe the general rules and regulations on low voltage technical devices.
Avoid shock and vibration during measurement, as these could adulterate the measurement results.
Inclination sensors that base on a fluidic measurement principle are optimal for static measurements
and suitable to only a limited extent of dynamic measurement.
5.3 Measurement
Tilt angle measurements are made in the ‘X’ and ‘Y’ axis’ (longitudinal and lateral respectively), with
the reference being the horizontal plane.
5.4 Mounting
For operation this inclinometer has to be mounted horizontally (see Fig. 5.1), reference is the base plate.
Fig. 5.1
Mounting position of sensor module & inclination axis
5.5 Mechanical data
Parameter
Symbol
Conditions
Min
Weight
Dimensions
Hauert 13, D-44227 Dortmund, Germany
Max
270
84 x 70 x 34.2
WxDxH
Unit
g
mm
IP 67
Protection class
MEAS Deutschland GmbH
Typ
www.meas-spec.com
6 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
5.6 Dimensions
The mechanical dimensions of the module are shown in Fig. 5.2
reference edge
(parallel to x-axis)
Fig. 5.2 Top and lateral views with dimensions of the inclinometer with metric cable screw
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
7 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
5.7 Label information
The label placed on top of the module contains the following information:
Type Code :
see table in chapter 2.2
HW/SW Code :
internal Hardware/Software-Versions
Serial No.:
YYWWNNNNN
Serial Number consists of nine digits. YY shows the year of production (2011=11), WW the week of
the production and NNNNN the unique number for identification and traceability.
5.8 Cable and configuration
The inclinometer is delivered with a cable of approximately 1 m length.
2
Type of cable:
LiYCY 6x0.14mm
Conductor resistance:
131 Ohm/km
Capacity:
90pF/m at 1kHz
Following configuration/cable color scheme is in use:
Cable
Name
Description
Type
color
White
Vcc
Positive power supply
Supply, Input
Yellow
GND
Ground
Supply, Input
Brown
Out X
Voltage output X
Output
Green
Out Y
Voltage output Y
Output
Grey
RxD
RS 232 input
Input
Pink
TxD
RS 232 output
Output
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
8 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
5.9 Connecting to a PC using an RS 232 interface
PC side
Sub D-connector 9 pins
Cable/wire of NS-xx/DPG2-x
Pin 2 RxD
white
Pin 3 TXD
brown
Pin 5 GND
green
yellow
grey
pink
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
+Ub
supply
positive power supply
(use ext. supply via battery, accu
or power pack)
Out output analogue voltage output signal xaxis
Outy output analogue voltage output signal yaxis
GND supply negative power supply, ground
(use ext. supply via battery, accu,
or power pack)
RxD
input
Rx, RS232 digital serial signal
TXD output Tx, RS232 digital serial signal
www.meas-spec.com
9 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
6
Interface
6.1 Digital Output RS232
For digital communication, the standardized RS 232-Interface (V24) is used in duplex mode.
After startup the sensor transmits the angle values in degrees (°) continuously.
6.1.1
Electrical Levels
RS232:
PARAMETER
VOH High-level output voltage
VOL Low-level output voltage
IIH High-level input current
IIL Low-level input current
(‡)
IOS Short-circuit output current
ΩO Output resistance
TEST
CONDITIONS
DOUT at RL = 3 kΩ to GND, DIN =
GND
DOUT at RL = 3 kΩ to GND, DIN = VCC
VI = VCC
VI at 0 V
Vcc = 5.5 V, VO = 0 V
Vcc, V+, and V− = 0 V, VO = ±2 V
MAX
−5
200
60
300
TYP
MIN
UNIT
9
5
V
(†)
−9
15
−1
5
±10
−20
0
−60
V
µA
µA
mA
Ω
(†) TA = 25°C.
(‡) Short-circuit durations should be controlled to prevent exceeding the device absolute power-dissipation ratings, and no more
than one output
6.1.2 Interface parameter for all NS–xx/DPG2–RUx (except NS–30/DPG2-RUN)
Baud rate:
9600 Baud
Format:
ASCII, 8 data bits, 1 stop bit, no parity
String length: 22 byte
Layout:
< D0 ... D21>
D0 ... D10
= “X=±xx.xxx“, <CR>, <LF>
Example:
with D2 = sign (+ or -)
with D5 = point
…
D11 ... D21 = “Y=±xx.xxx“, <CR>, <LF>
X=+00.430
with D13 = sign (+ or -)
Y=-00.084
with D16 = point
…
6.1.3 Interface parameter for NS–30/DPG2–RUN
Baud rate:
9600 Baud
Format:
ASCII, 8 data bits, 1 stop bit, no parity
String length: 20 byte
Layout:
< D0 ... D19>
D0 ... D9
= “X=±xx.xx“, <CR>, <LF>
with D2 = sign (+ or -)
with D5 = point
D10 ... D19 = “Y=±xx.xx“, <CR>, <LF>
with D12 = sign (+ or -)
with D15 = point
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
10 of 15
July 2015
Example:
…
X=+00.43
Y=-00.08
…
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
6.2 Programming commands
6.2.1
Command Reference user level
Default after power on or software reset.
Commands in
user level
Input
Output
Comment
Stop continuous
output of
inclination values
“s”
“s”
Stops the continuous output of angle
results or raw values, required for
input of commands, terminated by “S”
or Reset or Power On,
mode temporary
Start continuous
output of values
“S”
“X=+01.234”, CR, LF,
“Y=-00.007”, CR, LF,
“X=……”
Starts the continuous output of angle
results or raw values,
mode temporary
Version and serial
number
“V”
“DPL2 V1.8.0”, CR, LF,
“SN:123456789”, CR, LF,
Output of SW-Version and serial
number, use in stopped mode only
Read one value
“R”
“X=+01.234”, CR, LF,
“Y=-00.007”, CR, LF,
Output of 1 complete string, 1 x-value
and 1 y-value, only in stopped mode
Activate setup
level
“f”
“i”
“m”
“a”
“f”
“i”
“m”
“a”
Activate the setup level, chapter
6.2.2. Setup level can be deactivated
by sending “K” or resetting with “q”.
The controller automatically exits this
level after about 10 minutes of user
inactivity with a reset.
any other
no reaction
No reaction for commands from setup
level
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
11 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
6.2.2
Command Reference SETUP level
Setup level will be used for permanent settings, stored.
Commands in
setup level
Input
Output
Comment
This level will be terminated (reset)
automatically after about 10 minutes of
user inactivity.
Stop continuous
output of inclination
values
“c”
Start continuous
output of values
“C”
Set zero
“N”
“N”
Define 0° position. Offset is stored and
used even after reset.
Setback zero
“n”
“n”
Resets the offset displacement
Set lowpass filter
“M”,
f
“M”,
f
Input filter settings with count
f = “0”…”7”, other characters were
answered with “E”, see item 1) below.
Set output rate
“O”,
o
“O”,
o
Set output rate with count o = “1”...”6”,
other characters were answered with
“E”, see item 2) below.
Show internal
settings
“ ”
“O123 M123”, CR, LF
“OffX=+00.000
OffY=+00.000”, CR, LF
“Erase Cycl SegF:
+00255”, CR, LF
“O123”: internal setting of output rate in
10ms, “M123”: internal filter setting;
both values 255 => default settings
“Off..”: stored Offset values
“Erase Cycl Seg…”: active Segment
and number of erasure procedures for
this segment
Show currently
temperature [°C]
“T“
“T= 00.00”, CR,LF
Readout the currently temperature in
°C. Usable at > software version 2.0.2.
Without sign, positive temperature.
With sign `- `, negative temperature.
Software reset
“q”
“q”
Reset the sensor
Erase both Info
segments,
(switch to default
settings)
“E"
“Seg A deleted” , CR, LF
“Seg B deleted” , CR, LF
Erases the info segments of flash
storage banks, InfoA and InfoB. This
set all changed user values to default
settings
Forbidden command
“#”
“#”
Reserved for factory communication
*
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
“c”
Stops the continuous output of angle
results or raw values, required for input
of commands, terminated by “C”,
mode permanent,
query with “ R”, see chapter 6.2.1.
Start the continuous output of angle
results or raw values,
mode permanent, valid after reset.
www.meas-spec.com
12 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
1) Set low pass filter exponential, with count f =
“0”: Out value = current value
“1”: Out value = (current value + old out value) /2
“2”: Out value = (current value + 3 * old out value) /4
“3”: Out value = (current value + 7 * old out value) /8
“4”: Out value = (current value + 15 * old out value) /16
“5”: Out value = (current value + 31 * old out value) /32, default
“6”: Out value = (current value + 63 * old out value) /64
“7”: Out value = (current value + 127 * old out value) /128
“8”..9: reserved, undefined.
Above calculation was made every 10ms.
For example of time response see chapter 7.2.3: “Step response NS-15/DPG2-RUG”
2) Set output rate (strings per second, 1 string contains x and y-value) with count o =
“1”: 40ms (==25Hz)
“2”: 100ms (==10Hz), default
“3”: 250ms (==4Hz),
“4”: 500ms (==2Hz)
“5”: 1000ms (==1Hz) “6”: 2000ms (==0,5Hz)
“0”, “7”, “8”, “9”: not defined
6.2.3 Step response/filtering NS-15/DPG2-RUG
Step response NS-15/DPG-RUG, fast change from angle 5° to angle 0°, at Ta=25°C
Measured at output rate 25Hz.
6°
Step response NS-15/DPL2 UXG, 5°->0° at T=25°C
Step response time NS-15/DPG2-RUG, 5°->0° at T=25°C
φ
filter=1
filter=4
filter=5
filter=6
filter=7
5°
4°
3°
2°
1°
0°
-1°
-2°
0s
1s
2s
3s
4s
5s
t
For filter settings see command “M” f in chapter 6.2.2
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
13 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
6s
Instruction Manual
DPG-Series Inclinometer
7
Qualification Testing
7.1 Standards
The sensor NS-xx/DPG2-xxx complies with:
•
IEC/EN 60068-2-2
High Temperature Storage
Ta= 85°C, medium : air, 1000h
•
IEC/EN 60068-2-78
High Humidity
Ta= 85°C , RH= 85%, 1000h
•
IEC/EN 60068-2-27
Mechanical shock test
A=30g, t=11ms, halfsine, 50 cycles per axis
•
IEC/EN 60068-2-6
Vibration loading
10 to 150 Hz, 2.5mm amplitude, 5g const. acceleration,
1 octave/minute, 20 cycles per axis
•
IEC/EN 60068-2-14
Thermo shock
THigh=85°C ,TLow=-40°C,medium:air-air,Tdwell: 15min,
Tchange: 30sec,100 cycles
•
IEC/EN 61000-6-2
Interference resistance industry
•
IEC/EN 61000-6-4
Emitted interference industry
7.2 Periodical Testing
The periodical testing is done every 3 years in terms of a product audit.
7.3 Material Testing
All materials used in the process will be released by checking the corresponding supplier certificates
when available. A regular material analysis from an independent laboratory will not be scheduled.
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
www.meas-spec.com
14 of 15
July 2015
phone: +49-(0)231-9740-0
fax: +49-(0)231-9740-20
Instruction Manual
DPG-Series Inclinometer
8
Additional Information
8.1 Ordering Information
NORTH AMERICA
EUROPE
ASIA
Measurement Specialties, Inc.
1000 Lucas Way
Hampton, VA 23666
United States
Phone: +1-800-745-8008
Fax: +1-757-766-4297
Email: [email protected]
Web: www.meas-spec.com
MEAS Deutschland GmbH
Hauert 13
D-44227 Dortmund
Germany
Phone: +49-(0)231-9740-0
Fax: +49-(0)231-9740-20
Email: [email protected]
Web: www.meas-spec.com
Measurement Specialties China Ltd.
No. 26, Langshan Road
High-tech Park (North)
Nanshan District, Shenzhen 518057
China
Phone: +86-755-33305088
Fax: +86-755-33305099
Email: [email protected]
Web: www.meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to
the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein.
Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any
particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product
or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical
parameters can and do vary in different applications. All operating parameters must be validated for each customer application by