Moore 36M Multi-Point Recorder FEATURES & BENEFITS High resolution, four-color vacuum fluorescent display (VFD) provides information with exceptional color and clarity Six-color fiber tip dotting system delivers clear tracing Two, three, or six universal inputs, up to 6 contact event inputs, up to 12 relay outputs, and up to 4 analog outputs provide real flexibility Control Solutions - Recorders Easy front panel configuration simplifies start-up 50 PCMCIA memory card drive affords convenient data storage Die-cast door and steel case ensure operation in harsh industrial environments Requires only 9.29" (236 mm) depth behind the panel DESCRIPTION The Moore 36M Strip Chart Recorder displays information on a high resolution, four-color VFD, and delivers clear traces with a six-color fiber tip dotting system. Front panel configuration allows easy set-up, and a variety of input, output, and performance options provide extensive system flexibility. Moreover, its rugged steel case and die cast door are designed to meet the rigors of industrial environments. The four-color VFD creates exceptional color, vividly displaying five 12 mm characters for process value, twenty 4 mm characters for text and three 1 mm bargraphs. The display also shows the measured value of each channel with its associated descriptor or scale, as well as bargraph indication of the three channels’ values. Information is recorded in distinctive colors on the chart using six different fiber tip pens. Inputs are fully universal with V, mV, TC, RTD and contact inputs. Recorder inputs can also be used as contact inputs to trigger internal recorder actions. A dedicated six contact event input card and up to 12 relay outputs are also available. Up to four channels can be retransmitted as linearized currents or voltage signals to other instruments. The 36M is fully configurable from the front panel using local push buttons and text prompts. This allows direct access to operator changes, and access to password protected configurations. Data stored on a Type I PCMCIA data card may be formulated for analysis, presentation, storage, and archiving using standard spreadsheet packages. Stored data can include the recorder’s configuration that can be saved to the data card for archiving or to transfer it to another recorder. A variety of math, timer, totalizer, and counter functions offer full integrating and counting capabilities. These options make it possible to carry out even the most complex application-specific function, such as environmental parameter monitoring or gas flow compensation. The Moore 36M Multi-Point Recorder supports MODBUS® communications to ensure communication with other devices. Moore Process Automation Solutions www.moore-solutions.com SPECIFICATIONS Memory Configuration EEPROM ELECTRICAL Custom Linearization 1 table of 32 point pairs Power Requirements Line Power: 45 to 65 Hz; 90 to 264 Vac DC Power: 24/48 Vdc Consumption (max): 100 VA, 100W Fuse Type: None Interrupt Protection: 40 msec @ 75% instrument load ENVIRONMENTAL Temperature Limits Operating: 0 to 50°C Storage: -20 to +70°C Protection Door and Bezel: IP54 (similar to NEMA 3) Case Sleeve: IP31 (similar to NEMA 1) Shock/Vibration: IEC348, IEC873 recovers from 2G peak @ 10Hz to 150Hz EMC Electromagnetic Emissions: EN50081-2 Safety: To EN61010;Installation II; Pollution Category 2 Static: IEC801-2 level 4 to 15KV(air discharge, panel mounted, open door) Fast Transients: IEC801-3 (instrument within specification) IEC801-4 (automatic recovery from any error/ malfunctions) R.F. Immunity: IEC801-3 to 10V/m (level 3) + 1% on 0 to 100°C PROPERTIES Printing System Pen Type: 6 nib cartridge Pen Resolution: 0.2 mm Pen Colors: Ch. 1: violet; Ch. 2: red; Ch. 3: black; Ch. 4: green; Ch. 5: blue; Ch. 6: brown Pen Life: 1.5 x 106 dots per color Update Rate: 2 Hz Response Time: 1 pass every 1.5 seconds Paper Transport Type: Stepper motor driving sprocket tube Chart Speeds: 0 to 1,200 mm/hr (user selectable) Chart Type: 100 mm calibrated width, 16 meter Z-fold Input to Paper Accuracy: 0.5% of span Inputs Maximum Number: 2, 3, or 6 inputs Types Thermocouple: B, C, D, E, G2, J, K, L, N, R, S, T, U, Ni/NiMo, Platinel II RTD: 2/3-wire resistance temperature detector (not channel 1 if any other channel is a thermocouple input); Pt100, Pt1000, Ni100, Ni1000 Vdc: 38mV; 150mV; 1V; 10V dc milliamps (mA): External shunt required Ohms (Ω): 0 to 150Ω, 0 to 600Ω, 0 to 6KΩ Contact Closure: Not channel 1 Minimum: 250 msec Type Mix: Freely configurable Noise Rejection Common mode: >140dB (48 to 62 Hz ch to ch and ch to gr) Series mode: >60dB Maximum Comm. Mode 250V continuous Maximum Series Mode 45mV @ lowest range; 12V peak @ highest range Isolation 300V RMS (dc to 65Hz; EN61010) (or dc ch to ch and ch to gr) Dielectric Strength 1350 Vac for 1 min (ch to gr) 2300 Vac for 1 min (ch to ch) Insulation Resistance >10MΩ @ 500Vdc Control Solutions - Recorders Humidity Limits Operation: 5% to 80% RH (non-condensing) Storage: 5% to 90% RH (non-condensing) GENERAL PARAMETERS Input Impedance 38mV, 150mV, 1V range: >10MΩ 10V range: 68.8KΩ Overload Protection 50V peak Open Circuit Detection + 57 nA maximum Recognition Time: 500 msec Minimum Break Resistance: 10MΩ Data Storage Format PCMCIA data card (Type I) Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 51 Physical Panel (Bezel) Size: 5.7" x 5.7" (144 mm x 144 mm) Panel Cutout: 5.4" x 5.4" (138 mm x 138 mm) Depth Behind Panel: 9.29"/236 mm with terminal cover Panel Mounting: DIN43700; Vertical + 30° Weight: 7.75 lbs. (3.5 kg) OPTIONS Control Solutions - Recorders Communications RS422/RS485 Gould Modicon MODBUS® RTU 52 Math Pack Number of Derived Channels: 16 configurable Basic Functions: Off, const., add, subtract, multiply, divide, modulus Advanced Functions: (Includes Basic) Sq rt, ch avg, DV group avg, rolling avg, ex, 10x, in, log10, rate-of-change, sample and hold, ch min, DV group latch min, DV group cont min, ch max, DV group latch max, DV group cont max, 3rd order polynominal, F°, relative humidity, mass flow: linear; mass flow: sq rt; ZrO2 probe, high select, low select, switch, stopwatch, timestamp, O2 correction, percentile Event Input Board Maximum Number Inputs: 6 discrete contact closures or 16 coded (using binary codes on inputs 1-4, strobed @ input 5) Outputs Relay Outputs: Up to 12 Ratings for Resistive Loads (derate for inductive loads) Switching Voltage: 250Vac, 30Vdc Switching Power: 500VA, 60Ω Break Current: 2A within referenced voltage & power limits Retransmission Outputs Configurable Output Ranges: 0-20mA; 4-20mA; 1-5 V; 0-10V Transmitter Power Supply Outputs: 6 isolated 24Vdc Current: 20mA each output Permissible Load: 600Ω maximum ACCESSORIES Part number 4LA249556 GD201125 GD204080U050 IF247152U102 IF247152U104 IF247152U106 IF247152U107 LA207028U004 LA207028U006 Description 36M Multipoint Printhead 36P,M Chart, 50 line, Z-fold 36P,M Chart, 50 line, Roll 36P,M—128K SRAM Card 36P,M—512K SRAM Card 36P,M—2 Meg SRAM Card 36P,M—4 Meg SRAM Card (4)-250 ohm shunts for 36V/P/M (6)-250 ohm shunts for 36V/P/M INSTALLATION DRAWINGS Moore Process Automation Solutions www.moore-solutions.com MODEL NUMBER Chart Paper Recorder with Chart Annotation Power 1 90-264Vac (Set for 120 Vac) 2 24/28 Vdc 3 90-264 Vac (Set for 220/240 Vac) Pens 1 2 Isolated Universal Input Channels 2 3 Isolated Universal Input Channels 3 6 Isolated Universal Input Channels Chart Type and PCMCIA Drive Type 1 Z-fold and No Drive 2 Z-fold and Packed Data Storage Drive 3 Roll and No Drive 4 Roll and Packed Data Storage Drive Option Slot #1 N None 1 Relays-4NC 2 Relays-4NO 3 Relays-3 Form C 4 Retransmission-2 Outputs 5 Event Contacts-6 Inputs Option Slot #2 N None 1 Relays-4NC 2 Relays-4NO 3 Relays-3 Form C 4 Retransmission-2 Outputs Option Slot #3 N None 1 Relays-4NC 2 Relays-4NO 3 Relays-3 Form C Transmitter Supply (not available with 24 Vdc Operating Voltage Option) N No Supply 1 3 Channel Supply 2 6 Channel Supply Math 1 Basic Math 2 Advanced 3 Advanced + 32pt Characterizer 4 Advanced + 20 Messages 5 Advanced + 32pt Characterizer + 20 Messages Advanced Functions N None 1 2 Totalizers 2 4 Totalizers 3 6 Totalizers 4 6 each Timers, Counters 5 6 each Timers, Counters, Totalizers Communications N None A RS 485 Modbus Reserved for Factory Use N Certifications 1 CE 2 CE and CSA 36M 1 2 1 N N N N 1 N Americas +1 215 646 7400 ext. 6613 N N 1 Control Solutions - Recorders 36M Sample Model Number Asia Pacific +65 299 6051 Europe +44 1935 706262 53