Moore 36C Circular Chart Recorder FEATURES & BENEFITS Multi-tip fiber pen dotting system delivers six clear traces Allows up to six universal inputs for input flexibility Vivid vacuum fluorescent display (VFD) display permits quick and accurate assessment of channel values PCMCIA memory card drive allows easy data archiving Printing channel ranges eliminates the need for expensive special charts and reduces chart inventory Control Solutions - Recorders Optional NEMA 4X enclosure ensures operation in harsh industrial environments 54 Easy front panel configuration simplifies set-up Download capabilities to other recorders saves configuration time DESCRIPTION The Moore 36C Circular Chart Recorder offers excellent flexibility through the use of up to six universal inputs. Information is vividly displayed on a VFD, and cleanly recorded with a multi-tip fiber pen dotting system. Easy front panel set-up and a variety of output options make the 36C adaptable to a variety of applications. Channel information is displayed with measured value, channel number, engineering units, tag names, and alarm information status. Information is printed on the chart using a four-color, fiber tip print cartridge and can be recorded as any combination of trends, messages, alpha-numeric logs, and channel ranges. Printing channel ranges on the chart eliminate the need for special charts, which reduces inventory. Input options include V, mV, mA, TC, RTD, and contact, which can be used as contact inputs to trigger internal recording events. Up to four channels can be retransmitted as a linearized current or voltage signal to other instruments; up to 12 relay outputs can be employed for direct transmission. The 36C recorder is fully configurable from the front panel via local push-buttons and text prompts, allowing easy program modifications and access to password-protected configurations. Data stored on a Type I PCMCIA data card may be formulated for analysis, presentation, storage, and archiving using standard spreadsheet packages. Stored data can include the recorder’s configuration, which can be saved to a data card for archiving or to transfer it to another recorder. The 36C has math, timer, totalizer, and counter options, offering extensive integrating and counting capabilities. These options make it possible to handle even the most complex application-specific functions, such as gas flow compensation and environmental parameter monitoring. The Moore 36C Circular Chart Recorder supports MODBUS® communications for integration with other devices. Moore Process Automation Solutions www.moore-solutions.com GENERAL PARAMETERS SPECIFICATIONS ELECTRICAL Power Requirements Line Power: 45 to 65 Hz; 90 to 264 Vac DC Power: 20/53 Vdc Consumption (max): 100 VA (ac), 60Ω (dc) Fuse Type: None Interrupt Protection: 40 msec @ 75% instrument load ENVIRONMENTAL Temperature Limits Operating: 0 to 50°C Storage: -20 to +70°C Protection Door and Bezel: Standard: IP54 (similar to NEMA 3) Optional: IP65 (similar to NEMA 4 & 4X) EMC Electromagnetic Emissions: EN50081-2 Electromagnetic Susceptibility: EN50082-2 Safety: To EN61010; Installation II; Pollution Category 2 PROPERTIES Printing System Cartridge: Color: > 1 million dots Black: >1.5 million dots Pen Resolution: 0.2 mm Annotation: 39 characters maximum Update Rate: 2 Hz for all information Trace Update: 5 seconds minimum Response Time: 1 pass every 4 seconds Paper Transport Type: Stepper motor driving sprocket tube Chart Speeds: 1 to 960 hrs/rev Chart Type: 12 hr, 24 hr, 7 day & not timed Accuracy Chart Speed: 0.25% single turn Input to Paper: 0.3% of span Display: 0.03% of dc range in use Data Storage Format PCMCIA data card (Type I) Memory Configuration EEPROM Alarms Per Channel: 4 including derived values Types: High, low, deviation, rate of change Americas +1 215 646 7400 ext. 6613 Noise Rejection Common mode: >130dB (48 to 62 Hz ch to ch and ch to gr) Series mode: >60dB Maximum Comm. Mode 250V continuous Maximum Series Mode 45mV @ lowest range; 12V peak @ highest range Isolation 300V RMS (dc to 65Hz; EN61010 or dc ch to ch and ch to gr) Dielectric Strength 1350 Vac for 1 min (ch to gr) 2300 Vac for 1 min (ch to ch) Insulation Resistance >10MΩ @ 500Vdc Input Impedance 38mV, 150mV & 1V range: >10MΩ 10V range: +68.8KΩ Control Solutions - Recorders Humidity Limits Operation: 10% to 90% RH (non-condensing) Storage: 10% to 90% RH (non-condensing) Inputs Maximum Number: Up to 6 inputs Types Thermocouple: B, C, D, E, G2, J, K, L, N, R, S, T, U, Ni/NiMo, Platinel II RTD: 2/3-wire resistance temperature detector (not channel 1 if any other channel is a thermocouple input); Pt100, Pt1000, Ni100, Cu10, Ni120, JPt100, Pt100A Vdc: +38mV; +150mV; +1V; +10V dc milliamps (mA): External shunt required Ohms (Ω): 0 to 150Ω, 0 to 600Ω, 0 to 6KΩ Contact Closure: Not channel 1 Minimum: 500 msec Type Mix: Freely configurable, no contact on channel 1 Overvoltage Protection 50V peak Open Circuit Detection + 57 nA maximum Recognition Time: 500 msec Minimum Break Resistance: 10MΩ Physical Panel (Bezel) Size: 15.0" x 14.2" (380 mm x 360 mm) Panel Cutout: 13.6" x 13.4” (345 mm x 340 mm) Depth Behind Panel: 5.8"/148 mm with terminal cover Panel Mounting: Vertical +5°, -30° Weight: 15 lbs. (7 kg) Asia Pacific +65 299 6051 Europe +44 1935 706262 55 OPTIONS Control Solutions - Recorders Communications RS422/RS485 Gould Modicon MODBUS® RTU 56 Math Pack Number of Derived Channels: 16 configurable Basic Functions: Off, const., add, subtract, multiply, divide, modulus Advanced Functions: (Includes Basic) Sq rt, ch avg, DV group avg, rolling avg, ex, 10x, in, log10, rate-of-change, sample and hold, ch min, DV group latch min, DV group cont min, ch max, DV group latch max, DV group cont max, 3rd order polynominal, F°, relative humidity, mass flow: linear; mass flow: sq rt; ZrO2 probe, high select, low select, switch, stopwatch, timestamp, O2 correction, percentile Outputs Relay Outputs Up to 12 Ratings for Resistive Loads (derate for inductive loads) Switching Voltage: 250Vac, 30Vdc Switching Power: 500VA, 60Ω Break Current: 2A within referenced voltage & power limits Retransmission Outputs Configurable Output Ranges: 0 - 20mA; 4 - 20mA; 1-5 V; 0-10V Transmitter Power Supply Outputs: 6 isolated 24Vdc Current: 20mA each output Permissible Load: 600Ω maximum Totalizer Counter Output Up to 6 Timers Up to 6 configurable timers Counters Up to 6 eight-digit counters Custom Messages 20 configurable messages, each up to 20 characters long with embedded sequences Case Wall mounting; IP65 (similar NEMA 4 & 4X) Transmitter Power Supply Up to 6 channels ACCESSORIES Part number LA250280 GDTW0394U050 GDTW0394U060 GDTW0394U070 GDTW0394U080 GDTW0394U100 GDSV0394U050 GDSV0394U100 UM36-5 LA207029U003 LA207029U006 Description 36C Print cartridge, 4 color 50 Div,24Hr chart, box of 100 60 Div,24Hr chart, box of 100 70 Div,24Hr chart, box of 100 80 Div,24Hr chart, box of 100 100 Div,24Hr chart, box of 100 50 Div,7 day chart, box of 100 100 Div,7 day chart, box of 100 36C Options Manual (3)-250 ohm for 36C w/o xmtr supply (6)-250 ohm for 36C w/o xmtr supply Totalizers Up to 6 nine-digit totalizers INSTALLATION DRAWINGS Moore Process Automation Solutions www.moore-solutions.com MODEL NUMBER 36C 1 2 N N N N 1 N N N N N Control Solutions - Recorders 36C Circular Chart Recorder Power 1 90-264 Vac (Set for 120 Vac) 2 24/28 Vdc 3 90-264 Vac (Set for 220/240 Vac) Pens 1 1 Isolated Universal Input Channel 2 2 Isolated Universal Input Channels 3 3 Isolated Universal Input Channels 4 4 Isolated Universal Input Channels 5 6 Isolated Universal Input Channels PCMCIA Drive N No drive 1 Configuration / Packed Data Storage Drive Option Slot #1 N None 1 2 Relays 2 4 Relays 3 6 Relays 4 Retransmission-2 Outputs1 5 Retransmission-4 Outputs1 Option Slot #2 N None 1 2 Relays 2 4 Relays 3 6 Relays Communication and Transmitter Supply (Transmitter supply not available with 24 Vdc Power Option) N No RS485 Modbus and No Supply 1 No RS485 Modbus and 3 Channel Supply 2 No RS485 Modbus and 6 Channel Supply 3 RS485 Modbus and No Supply 4 RS485 Modbus and 3 Channel Supply 5 RS485 Modbus and 6 Channel Supply Derived Math Channel 1 Basic Math 2 Advanced 3 Advanced + 32pt Characterizer 4 Advanced + 20 Messages 5 Advanced + 32pt Characterizer + 20 Messages Advanced Functions N None 1 2 Totalizers 2 4 Totalizers 3 6 Totalizers 4 6 each Timers, Counters 5 6 each Timers, Counters, Totalizers Totalizer Outputs N None 1 2 Totalizer Outputs (includes 2 relay option) 2 4 Totalizer Outputs (includes 4 relay option) 3 6 Totalizer Outputs (includes 6 relay option) Case and Mounting N NEMA 3 and Panel 1 NEMA 3 and 2" Pipe 2 NEMA 4 and Panel 3 NEMA 4 and 2" Pipe 4 NEMA 4X and Panel 5 NEMA 4X and 2" Pipe Reserved for Factory Use N Certifications N None 1 CSA2 2 CSA Class I, Div. 2, Group A, B, C, D2 3 CE Approval 4 CE and CSA Class I, Div. 2, Group A, B, C, D2 Sample Model Number NOTES: (1) Consult Moore for availability of retransmission ouptuts. (2) CSA approval pending - consult Moore. Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 57