Model 36C

Moore 36C Circular Chart Recorder
FEATURES & BENEFITS
Multi-tip fiber pen dotting system delivers six clear traces
Allows up to six universal inputs for input flexibility
Vivid vacuum fluorescent display (VFD) display permits quick and accurate assessment of channel values
PCMCIA memory card drive allows easy data archiving
Printing channel ranges eliminates the need for expensive special charts and reduces chart inventory
Control Solutions - Recorders
Optional NEMA 4X enclosure ensures operation in
harsh industrial environments
54
Easy front panel configuration simplifies set-up
Download capabilities to other recorders saves configuration time
DESCRIPTION
The Moore 36C Circular Chart Recorder offers excellent
flexibility through the use of up to six universal inputs.
Information is vividly displayed on a VFD, and cleanly
recorded with a multi-tip fiber pen dotting system. Easy
front panel set-up and a variety of output options make the
36C adaptable to a variety of applications.
Channel information is displayed with measured value, channel number, engineering units, tag names, and alarm information status. Information is printed on the chart using a
four-color, fiber tip print cartridge and can be recorded as
any combination of trends, messages, alpha-numeric logs,
and channel ranges. Printing channel ranges on the chart
eliminate the need for special charts, which reduces inventory.
Input options include V, mV, mA, TC, RTD, and contact,
which can be used as contact inputs to trigger internal recording events. Up to four channels can be retransmitted
as a linearized current or voltage signal to other instruments; up to 12 relay outputs can be employed for direct
transmission.
The 36C recorder is fully configurable from the front panel
via local push-buttons and text prompts, allowing easy program modifications and access to password-protected
configurations.
Data stored on a Type I PCMCIA data card may be formulated for analysis, presentation, storage, and archiving using standard spreadsheet packages. Stored data can include
the recorder’s configuration, which can be saved to a data
card for archiving or to transfer it to another recorder.
The 36C has math, timer, totalizer, and counter options, offering extensive integrating and counting capabilities. These
options make it possible to handle even the most complex
application-specific functions, such as gas flow compensation and environmental parameter monitoring.
The Moore 36C Circular Chart Recorder supports MODBUS® communications for integration with other devices.
Moore Process Automation Solutions
www.moore-solutions.com
GENERAL PARAMETERS
SPECIFICATIONS
ELECTRICAL
Power Requirements
Line Power: 45 to 65 Hz; 90 to 264 Vac
DC Power: 20/53 Vdc
Consumption (max): 100 VA (ac), 60Ω (dc)
Fuse Type: None
Interrupt Protection: 40 msec @ 75% instrument
load
ENVIRONMENTAL
Temperature Limits
Operating: 0 to 50°C
Storage: -20 to +70°C
Protection
Door and Bezel:
Standard: IP54 (similar to NEMA 3)
Optional: IP65 (similar to NEMA 4 & 4X)
EMC
Electromagnetic Emissions: EN50081-2
Electromagnetic Susceptibility: EN50082-2
Safety: To EN61010; Installation II; Pollution
Category 2
PROPERTIES
Printing System
Cartridge: Color: > 1 million dots
Black: >1.5 million dots
Pen Resolution: 0.2 mm
Annotation: 39 characters maximum
Update Rate: 2 Hz for all information
Trace Update: 5 seconds minimum
Response Time: 1 pass every 4 seconds
Paper Transport
Type: Stepper motor driving sprocket tube
Chart Speeds: 1 to 960 hrs/rev
Chart Type: 12 hr, 24 hr, 7 day & not timed
Accuracy
Chart Speed: 0.25% single turn
Input to Paper: 0.3% of span
Display: 0.03% of dc range in use
Data Storage Format
PCMCIA data card (Type I)
Memory Configuration
EEPROM
Alarms
Per Channel: 4 including derived values
Types: High, low, deviation, rate of change
Americas +1 215 646 7400 ext. 6613
Noise Rejection
Common mode: >130dB (48 to 62 Hz ch to ch and
ch to gr)
Series mode: >60dB
Maximum Comm. Mode
250V continuous
Maximum Series Mode
45mV @ lowest range; 12V peak @ highest range
Isolation
300V RMS (dc to 65Hz; EN61010 or dc ch to ch
and ch to gr)
Dielectric Strength
1350 Vac for 1 min (ch to gr) 2300 Vac for 1 min
(ch to ch)
Insulation Resistance
>10MΩ @ 500Vdc
Input Impedance
38mV, 150mV & 1V range: >10MΩ
10V range: +68.8KΩ
Control Solutions - Recorders
Humidity Limits
Operation: 10% to 90% RH (non-condensing)
Storage: 10% to 90% RH (non-condensing)
Inputs
Maximum Number: Up to 6 inputs
Types
Thermocouple: B, C, D, E, G2, J, K, L, N, R, S, T,
U, Ni/NiMo, Platinel II
RTD: 2/3-wire resistance temperature detector
(not channel 1 if any other channel is a
thermocouple input); Pt100, Pt1000, Ni100,
Cu10, Ni120, JPt100, Pt100A
Vdc: +38mV; +150mV; +1V; +10V dc milliamps
(mA): External shunt required
Ohms (Ω): 0 to 150Ω, 0 to 600Ω, 0 to 6KΩ
Contact Closure: Not channel 1
Minimum: 500 msec
Type Mix: Freely configurable, no contact on
channel 1
Overvoltage Protection
50V peak
Open Circuit Detection
+ 57 nA maximum
Recognition Time: 500 msec
Minimum Break Resistance: 10MΩ
Physical
Panel (Bezel) Size: 15.0" x 14.2" (380 mm x 360
mm)
Panel Cutout: 13.6" x 13.4” (345 mm x 340 mm)
Depth Behind Panel: 5.8"/148 mm with terminal
cover
Panel Mounting: Vertical +5°, -30°
Weight: 15 lbs. (7 kg)
Asia Pacific +65 299 6051
Europe +44 1935 706262
55
OPTIONS
Control Solutions - Recorders
Communications
RS422/RS485 Gould Modicon MODBUS® RTU
56
Math Pack
Number of Derived Channels: 16 configurable
Basic Functions: Off, const., add, subtract,
multiply, divide, modulus
Advanced Functions: (Includes Basic) Sq rt,
ch avg, DV group avg, rolling avg, ex, 10x, in,
log10, rate-of-change, sample and hold, ch min,
DV group latch min, DV group cont min, ch max,
DV group latch max, DV group cont max, 3rd
order polynominal, F°, relative humidity, mass
flow: linear; mass flow: sq rt; ZrO2 probe, high
select, low select, switch, stopwatch, timestamp,
O2 correction, percentile
Outputs
Relay Outputs Up to 12
Ratings for Resistive Loads (derate for inductive
loads)
Switching Voltage: 250Vac, 30Vdc
Switching Power: 500VA, 60Ω
Break Current: 2A within referenced voltage &
power limits
Retransmission Outputs
Configurable Output Ranges: 0 - 20mA; 4 - 20mA;
1-5 V; 0-10V
Transmitter Power Supply
Outputs: 6 isolated 24Vdc
Current: 20mA each output
Permissible Load: 600Ω maximum
Totalizer Counter Output
Up to 6
Timers
Up to 6 configurable timers
Counters
Up to 6 eight-digit counters
Custom Messages
20 configurable messages, each up to 20 characters
long with embedded sequences
Case
Wall mounting; IP65 (similar NEMA 4 & 4X)
Transmitter Power Supply
Up to 6 channels
ACCESSORIES
Part number
LA250280
GDTW0394U050
GDTW0394U060
GDTW0394U070
GDTW0394U080
GDTW0394U100
GDSV0394U050
GDSV0394U100
UM36-5
LA207029U003
LA207029U006
Description
36C Print cartridge, 4 color
50 Div,24Hr chart, box of 100
60 Div,24Hr chart, box of 100
70 Div,24Hr chart, box of 100
80 Div,24Hr chart, box of 100
100 Div,24Hr chart, box of 100
50 Div,7 day chart, box of 100
100 Div,7 day chart, box of 100
36C Options Manual
(3)-250 ohm for 36C w/o xmtr
supply
(6)-250 ohm for 36C w/o xmtr
supply
Totalizers
Up to 6 nine-digit totalizers
INSTALLATION DRAWINGS
Moore Process Automation Solutions
www.moore-solutions.com
MODEL NUMBER
36C 1
2
N
N
N
N
1
N
N
N
N
N
Control Solutions - Recorders
36C Circular Chart Recorder
Power
1
90-264 Vac (Set for 120 Vac)
2
24/28 Vdc
3
90-264 Vac (Set for 220/240 Vac)
Pens
1
1 Isolated Universal Input Channel
2
2 Isolated Universal Input Channels
3
3 Isolated Universal Input Channels
4
4 Isolated Universal Input Channels
5
6 Isolated Universal Input Channels
PCMCIA Drive
N
No drive
1
Configuration / Packed Data Storage Drive
Option Slot #1
N
None
1
2 Relays
2
4 Relays
3
6 Relays
4
Retransmission-2 Outputs1
5
Retransmission-4 Outputs1
Option Slot #2
N
None
1
2 Relays
2
4 Relays
3
6 Relays
Communication and Transmitter Supply (Transmitter supply not available with 24 Vdc Power Option)
N
No RS485 Modbus and No Supply
1
No RS485 Modbus and 3 Channel Supply
2
No RS485 Modbus and 6 Channel Supply
3
RS485 Modbus and No Supply
4
RS485 Modbus and 3 Channel Supply
5
RS485 Modbus and 6 Channel Supply
Derived Math Channel
1
Basic Math
2
Advanced
3
Advanced + 32pt Characterizer
4
Advanced + 20 Messages
5
Advanced + 32pt Characterizer + 20 Messages
Advanced Functions
N
None
1
2 Totalizers
2
4 Totalizers
3
6 Totalizers
4
6 each Timers, Counters
5
6 each Timers, Counters, Totalizers
Totalizer Outputs
N
None
1
2 Totalizer Outputs (includes 2 relay option)
2
4 Totalizer Outputs (includes 4 relay option)
3
6 Totalizer Outputs (includes 6 relay option)
Case and Mounting
N
NEMA 3 and Panel
1
NEMA 3 and 2" Pipe
2
NEMA 4 and Panel
3
NEMA 4 and 2" Pipe
4
NEMA 4X and Panel
5
NEMA 4X and 2" Pipe
Reserved for Factory Use
N
Certifications
N
None
1
CSA2
2
CSA Class I, Div. 2, Group A, B, C, D2
3
CE Approval
4
CE and CSA Class I, Div. 2, Group A, B, C, D2
Sample Model Number
NOTES:
(1)
Consult Moore for availability of retransmission ouptuts.
(2)
CSA approval pending - consult Moore.
Americas +1 215 646 7400 ext. 6613
Asia Pacific +65 299 6051
Europe +44 1935 706262