SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Overview Crystal Clear Display • Digital Colour LCD (TFT) • Resolution - SIREC D300: QVGA Resolution (320 x 240 pixels) - SIREC D400: SVGA Resolution (800 x 600 pixels) • Clear and intuitive operation • Industrial rugged Touch Screen with rapid navigation • Custom Screens ■ Function Display 12.1” Colour Active TFT (SIREC D300)/5.5” Colour Active TFT (SIREC D400) With more than 256,000 colours makes it easy to interpret process data and take action with the intuitive bar charts, digital values, trends or customised displays. A screen saver function can be set from 1 to 720 minutes to extend the life of the backlight. Comprehensive Connectivity • 10/100 Ethernet (DHCP), Web, Email, OPC Server • FTP, TCP/IP and RS485 Modbus Protocol • USB ports for keyboard and mouse Touch Screen Data Storage • On-board non-volatile memory - up to 1850 MByte • Removable Compact Flash and USB storage • No moving parts - all solid state data storage Navigation through the menus and text entry are direct and intuitive: The heavy duty durable touch screen provides easy data entry and rapid navigation though the menus. The touch screen operator interface provides fast, easy access to the recorder menus making set up and data analysis quick and efficient. Security Stringent - Total Data integrity • Password Protection - 21CFR Part 11 • ESS - Extended Security System Plus.. • Health Watch for preventative maintenance • Remote Access - Advanced Software Data Analysis • Analysis at your PC • Independent Chart and Logging speeds • Global Language Support • Rapid review and replay of data at recorder • Approvals - CE, CSA, UL, FM • NEMA 4X/IP66 (option) • Up to 50 Hz (20 ms) Logging • Analog Inputs - SIREC D300: Up to 16 Analog Inputs - SIREC D400: Up to 48 Analog Inputs • Remote Viewing Tool Example of a recorder menu path from the Main Menu to Pen Scale configuration with clear rapid navigation Siemens MP 20 News · 2007 13 SIREC D Display Recorder SIREC D300 and SIREC D400 Standard Screens Language Support Up to 20 screens (SIREC D300) respectively 30 screens (SIREC D400) displaying multiple combinations of Charts, Bars and Digitals can be configured, 4 respectively 6 (SIREC D300 respectively SIREC D400) examples below. Standard language prompts for • English UK & US • French • German • Italian • Spanish • Portuguese • Brazilian • Polish • Slovakian • Czech • Turkish • Romanian • Hungarian • Russian Communications The recorder supports FTP, Modbus TCP/IP (slave mode), Web and Email over Ethernet (DHCP standard) communications port and Modbus RTU (slave mode) via an RS485 port. USB ports allow the use of an ASCII barcode reader. Email sent to your network connected PC triggered by an Alarm or an Event. Ethernet Connectivity The Ethernet (DHCP standard) connection, with support for various protocols, provides unlimited connectivity to local area networks (LANs). The standard Ethernet interface makes networking of the recorder to a LAN or the world wide web fast and convenient. Dynamic Host Configuration Protocol (DHCP) automatically acquires the settings (IP address) for network communications from a DHCP server. RS485 Modbus The RS485 connection allows process data to be transferred to other devices, or to record data received in MODBUS RTU protocol (slave mode only). Simple Network Time Protocol (SNTP) The recorder can be synchronised over the ethernet network via a SNTP client or synchronise other recorders via a Server. Help Files A complete contextual help system can be accessed and visualised on the screen of the recorder. Logarithmic Scales All displayed scales can be set as linear or logarithmic. Replay with Zoom Select replay mode and zoom-in on a specific area on the screen. The data can easily be replayed at the recorder with the ability to “zoom”. The touch screen makes it fast to review and analyse historical data. A "Jump" function allows you to go from any message list directly to the trend showing the occurence of the alarm. Web Server With the recorder connected to a LAN, all process variables, alarm and messages can be viewed from an internet browser with automatic refresh. USB Ports Front and rear USB host ports for data and setup transfers or remote screen through this port. Front USB port is standard and the rear USB port is available with the Communications card option. Use these ports to attach external devices (keyboard or mouse), for direct interfacing with the recorder. Common Relay Output A separate relay alarm output at the rear of the unit can be set up as an alarm output. Remote Viewer Extends the user interface of the recorder onto the desktop PC. Providing remote viewing of the unit launched from a web browser. Full remote control is available as an option. Compatible with Microsoft™ Internet explorer 6 and higher. 14 Siemens MP 20 News · 2007 SIREC D Display Recorder SIREC D300 and SIREC D400 Data Storage Data Security Internal Data Storage Total Data Integrity 70MB to 400MB expandable internal non-volatile flash memory is available for data storage and chart history. Data is stored in secure encrypted files making it easy to retrieve the data dependent on process information. Data is automatically recognised without having to remember file names. Pens 70 MByte 180 MByte 400 MByte 890 MByte 1850 MByte 16 12 Days 30,5 Days 68,5 Days 32 6 Days 15 Days 34 Days 48 4 10 Days 22 Days 96 2 5 Days 11 Days 25 Days 51 Days 311 Days Password Protection 75 Days 155 Days 50 Days 103 Days Up to 4 levels of password protection with up to 50 different users are available. Multiple level of password protection and an audit trail of actions enhance the security of the data. 750 Days Internal memory (Logging rate = 1 s) - SIREC D400 Extended Security System (option) 8 24 Days 61 Days 137 Days 301 Days 622 Days ESS provides extended features including entry of unique User ID’s and associate passwords, time-out of password entry, password expiration, and traceability of user actions. ESS is compatible with the requirements of 21CFR part 11. 16 12 Days 30,5 Days 68,5 Days 750 Days 311 Days Safety Standards 32 6 Days 15 Days 34 Days 75 Days 155 Days CE Mark Pens 70 MByte 180 MByte 400 MByte 890 MByte 1850 MByte Internal memory (Logging rate = 1 s) - SIREC D300 Data Export Conformity with 73/23/EEC, Low Voltage Directive and 89/336/EEC EMC Directive. Removable compact flash and USB flash storage device provides multiple data storage alternatives. Data is stored in a secure binary encrypted format, with the recorder’s configurations, providing added security of the data files. Removable Compact flash and USB flash storage devices. Enclosure rating Events "Wire seal provision” that provides added security to seal the front door and rear wiring when using optional rear cover to prevent undetected entry to these areas of the recorder. Certain conditions or operations can be set up and logged according to the time and date of the occurrence. Subsequently events can be reviewed in a list or represented on a graph. Standard NEMA 3/IP54 type front face protection. NEMA 4X/IP66 available as an option. Security tag Batch Batch enhances the management of data collected in non-continuous process, known as batch processing, used in thermal treatment, sterilisation, food processing and chemical reactions. Soft Alarms 6 "software" alarms per pen are easily set up to display and record selected out-of-limit conditions. These can be tied to the relay or digital outputs to activate the user’s external equipment. Independent Display Chart Speeds and Logging rates Logging rates can be programmed completely separate from the chart display speed, allowing the data to be displayed and stored at the rates that best suits the application. Fuzzy Logging This standard feature provides a unique method to increase the storage capacity of the recorder. The data is monitored to determine changes in process data; if no changes are observed data is logged periodically. If data is changing rapidly, it is recorded normally at the programmed rate. By not logging data that is static, data compression of up to 100:1 or more can be achieved saving valuable memory. Pulse Inputs The 8 Digital I/O option card has 4 channels that can be set as pulse inputs (first 4 channels). The operating frequency for pulse inputs on the Digital I/O card is 1kHz max. Siemens MP 20 News · 2007 15 SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Technical specifications Standard Screens and Custom Screens Design Attributes Display size and Type Diagonal, Digital Colour LCD (TFT) with Touch Screen Industrial grade with brightness adjustment and wide viewing angle • SIREC D300 5.5“ (14 cm) diagonal, color • SIREC D400 12.1“ (30.7 cm) diagonal, color Resolution • SIREC D300 QVGA (320 x 240 pixels) • SIREC D400 SVGA (800 x 600 pixels) Screen Saver Set in minutes from 1 … 720, can be set to dim the screen or to switch off Brightness adjustment Adjustable between 10 and 100%, default set to 80% brightness. Backlight life time • SIREC D300 • SIREC D400 55,000 hours to half brightness when used at 100% (86,000 h if used at 80%). Maximum luminosity 400 cd/m² Data Storage • Removable Media 43,000 hours to half brightness when used at 100% (67,000 h if used at 80%). Maximum luminosity 400 cd/m² Compact Flash card, supports up to 1850 MByte • Local Mass Storage Options • USB memory key - up to 2 GByte • USB hard drive - up to 120 GByte • Internal Data Buffer Non-volatile, 70 MByte (16 million acquisition values) upwards to 1,850 MByte (400 Million points) • Setup and screens Stored internally on non-volatile memory • Manual Saving Data saving by inserting compact flash card or USB memory stick • Data Saving Period Related to log rate, number of pens, totals and alarms. Each pen is capable of its own independent storage rate (20 ms … 60 h) Display Update Rate Display values updated every second Status Display A status bar, at the top of the recorder’s screen, displays the real-time icons of the recorder status, such as Recording Time left and alarm active Communications Mathematics Ethernet 10/100 base -T with RJ45 connector supporting Modbus/TCP, FTP, Internet, DHCP or fixed IP address. RS485 Modbus RTU (up to 115200 Baud Rate) Basic Maths include Add, Subtract, Multiply, Divide, Modulo and power. Full Maths and Scripting (option) support up to 100 character free form math expression for each pen. For example SINE, COS, TAN, Log, Parenthesis (eg. A1 + A2), comm variables, free memory, and access to any data item variable (A1, P1, D1 etc.). Front and Rear USB Ports Fully programmable display values in engineering units. Time & date stamp on every division. Sets of Standard screens are available to display data on a chart, digital reading, bargraphs or numerous combinations thereof. Screen properties can be modified on the recorder and customised to suit. Custom screens created in the Screen Designer software can be imported into the recorder for specialist applications. Custom Screen firmware option is required. Digital values displayed include • alarms on bars, • engineering units, • pen name, • Measuring point number • tag, time and date, • 20 character description and • totalised values. USB host ports front and rear for data and setup transfers through these ports. External devices (keyboard or mouse), Barcode reader, or external mass storage device. (USB 1.1 compliant) • Data Format Binary encoded format • Recycling Mode Internal memory has FIFO (First In First Out) capability where the newest data over-writes the oldest data Power Requirements • Voltage (VRMS) 100 V AC … 250 V AC (auto select) • Frequency 50/60 Hz • Power Consumption - SIREC D300 < 40 W - SIREC D400 < 60 W • Optional instrument power Voltage - SIREC D300 20 … 55 V DC / 20 … 30 V AC Power Consumption: < 40 W - SIREC D400 20 … 55 V DC / 20 … 30 V AC Power Consumption: < 60 W Common Relay Output (SPNC) 16 Siemens MP 20 News · 2007 • NC common alarm relay 2 contacts, normally open when the recorder is powered (no active alarms), rating 24 V, 1 A Battery Battery backed up for clock, Lithium battery Type 6032, 3.0 V – 10 years life (Recorder powered), 4 years life, typical (Recorder unpowered) SIREC D Display Recorder SIREC D300 and SIREC D400 Password Protection Multiple Administrator control of password setup and management with 4 levels of password protection for – Engineer, Supervisor, Technician, and Operator. Up to 50 different users are available. Password protection restricts user entry to the recorder set up and specific screens. • Engineer Highest access to all levels, Supervisor, Technician and Operator • Supervisor 2nd highest level including Technician and Operator access • Technician 3rd level including Operator access • Operator 4th and lowest level of access Languages • English UK & US • French • German • Italian • Spanish • Portuguese • Brazilian • Polish • Slovakian • Czech • Turkish • Romanian • Hungarian • Russian Temperature Units °C, °F oder K (Kelvin) Recorder Identification Status bar: Alternately displays Recorder ID and Recorder Screen Name. Displays Time and Date. Clock Alarm Set Points • Alarm triggers Accuracy: ± 29 ppm (± 1 minute/month) at 25°C. Summer/Winter manual or automatic time adjustment or via communications. SNTP Client and/or Server included for synchronising over Ethernet. 6 per pen integral “soft” alarm set points easily set by user to announce selected out of limit conditions; user can select if an alarm triggers a change in the screen background colour Alarm triggers can be set for Hi, Lo, Deviation (latched or unlatched) for alarm acknowledgement • Alarm Damping 1 s … 24 h • Hysteresis ± 100% of pen scale • Common relay output 1 A , 24 V; can be activated on any alarm Data Replay Mode Data replay facility on chart displays at normal, fast or slow speeds with zoom and cursor Display Chart Speeds • Chart rates • 1 mm/h • 5 mm/h • 10 mm/h • 20 mm/h • 30 mm/h • 60 mm/h • 120 mm/h • 600 mm/h • 1200 mm/h • 6000 mm/h Combinations of rates can be mixed and chart speeds can be set independently for each chart. Display speeds are independent of logging rate. Messages Screen The message screen displays system information and records any setup activity that has been changed. It also provides warning and error message updates, lists alarm activity and will display user defined marks on a chart. CE Conformity (CE Mark) This product conforms with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Immunity Product Classification Complies with EN 61326 Class I: Cord Connected, Panel Mounted Industrial Control Equipment with protective earthing (grounding), EN 61010-1 Enclosure Rating Front panel designed to NEMA3/IP54 (Optional NEMA 4X/IP66) Installation Requirements Category II: Overvoltage (EN 61010-1) Pollution Degree 2 EMC Standards Emissions - EN 61326 Class B Immunity - EN 61326 Industrial Levels Safety Complies with EN 61010-1: 2001 Panel Mounted Equipment, Terminals must be enclosed within the panel Analog Inputs Number of Inputs • SIREC D300 4, 6, 8, 12 or 16 input channels • SIREC D400 4, 6, 8, 12, 16, 24, 32, 40 or 48 input channels Input Types mV, V, mA with external shunt (provided as standard), Thermocouple, RTD and ohms Minimum Input Span Range is fully configurable with span limitation of the operating range selected with 4% under range to 4% over-range capability (50 V Range 2%) Burnout (T/C) Active (High or Low), Passive and Health watch/maintenance (option). Cold Junction Compensation Internal compensation with the ability to manually adjust values, External Input for compensation, External CJC value specified Siemens MP 20 News · 2007 17 SIREC D Display Recorder SIREC D300 and SIREC D400 Input Resolution 0.0015% (16 Bit ADC) •L -200 ... 0 °C (-328 ... 32 °F) 0 ... 900 °C (32 ... 1652 °F) 10 Ω, use ± 0.1% external resistor, Volts > 1 MΩ, all other > 10 MΩ • G (W_W26) 0 ... 100 °C (32 ... 212 °F) 100 ... 316 °C (212 ... 601 °F) 316 ... 2315 °C (601 ... 4199 °F) • C (W5, W26) 0 ... 180 °C (32 ... 356 °F) 180 ... 1220 °C (356 ... 2228 °F) 1220 ... 2315 °C (2228 ... 4199 °F) • M (NiMo-NiCo) (NNM90) -50 ... 370 °C (-58 ... 698 °F) 370 ... 1410 °C (698 ... 2570 °F) • N (Nicosil Nisil) -200 ... 100 °C (328 ... 212 °F) 100 ... 1300 °C (212 ... 2372 °F) Input Impedance • Current loop resistance Source Impedance • T/C and RTD 100 Ω per lead maximum (Cu10 = 15 Ω) Square Root Extraction Available as standard on every input type Sensor Compensation Single point and Dual point Input Sampling Rate • SIREC D300 Recorder has 2 available slots with up to 8 analog inputs each; the input sampling rate is dependent on actuation type • SIREC D400 Recorder has 6 available slots with up to 8 analog inputs each; the input sampling rate is dependent on actuation type • All Inputs 100 ms (10 Hz), 200 ms (5 Hz), 500 ms (2 Hz) • Fast Sampling 20 ms (50 Hz) - mA, mV, Volts and Ohms only Linear Scales • Normal and Scientific notation • Decimal Point automatic or programmable • Engineering units, user definable (10 characters) Logarithmic Scales Logarithmic Decade limits: -38 min, to +38 max, (recommend up to 20 decades on one screen to ensure clarity) • Chromel/Copel -50 ... 600 °C (-58 ... 1112 °F) • P (Platinel) 0 ... 1390 °C (32 ... 2534 °F) •D 0 ... 180 °C (32 ... 356 °F) 180 ... 1840 °C (356 ... 3344 °F) 1840 ... 2490 °C (3344 ... 4515 °F) Resistance thermometers Temperatur range • Pt100 α = 0,00385 -200 ... 850 °C (-328 ... 1562 °F) • Pt200 -200 ... 850 °C (-328 ... 1562 °F) • Pt500 -200 ... 850 °C (-328 ... 1562 °F) • Pt1000 -200 ... 850 °C (-328 ... 1562 °F) • Nickel, 100 Ω -60 ... 180 °C (-76 ... 356 °F) • Nickel, 120 Ω -80 ... 260 °C (-112 ... 500 °F) • Cu10 -200 ... 260 °C (-328 ... 500 °F) • Cu53 0 ... 150 °C (32 ... 302 °F) Logging Logging Method Input Isolation 300 V AC channel-to-channel, channel-to-ground Sample, Average, Min/Max - can be set independently per pen Logging Types Continuous, Fuzzy Noise Rejection At 50/60Hz ± 2% Logging Rate From 200 ms … 60 h per Pen • Common mode 2 Hz = -120 dB, 5 Hz = -120 dB, 10 Hz = -120 dB Fuzzy Logging • Normal Mode 2 Hz = -85 dB, 5 Hz = -80 dB, 10 Hz = -48 dB A secure data storage technique which delivers data compression ratio of 100:1 or more; self teaching, storing the data at a variable rate to match the process Input Actuation (Linear) Range • mV (DC) -1000 … +1000 • V (DC) -50 … +50 Mechanical Design Enclosure/Bezel Zinc plated steel case with high impact resistant polycarbonate bezel; scratch resistant lens • Enclosure Rating • NEMA 3/IP54 protection rating standard • Optional NEMA 4X/IP66 (Front face only) • mA 4 … 20, 0 … 20 • 200 Ω 0 … 200 • 500 Ω 0 … 500 • 1000 Ω 0 … 1000 • 4000 Ω 0 … 4000 • Colour Bezel: Grey Thermocouples Temperatur range Mounting Panel •B 260 ... 538 °C (500 ... 1000 °F) 538 ... 1816 °C (1000 ... 3300 °F) •E -270 ... -200 °C (-454 ... -328 °F) -200 ... -70 °C (-328 ... -94 °F) -70 ... 1000 °C (-94 ... 1832 °F) •J -210 ... 0 °C (-346 ... 32 °F) 0 ... 1200 °C (32 ... 2192 °F) •K -270 ... -70 °C (-454 ... -94 °F) -70 ... 1372 °C (-94 ... 2502 °F) •R -50 ... 260 °C (-58 ... 500 °F) 260 ... 1768 °C (500 ... 3214 °F) •S -50 ... 260 °C (-58 ... 500 °F) 260 ... 1768 °C (500 ... 3214 °F) •T -270 ... -210 °C (-454 ... -346 °F) -210 ... 400 °C (-346 ... 752 °F) Unlimited mounting angle For the best view of the display the viewing angle should not exceed: SIREC D300 • 55° from the left or right, • 40° looking down and • 50° looking up at the recorder display. SIREC D400 • 70° from the left or right, • 45° looking down and • 55° looking up at the recorder display. Mounting adjustable for panel thickness of 2 mm … 20 mm. Adapter kits available for covering existing panel cutouts. 18 Siemens MP 20 News · 2007 SIREC D Display Recorder SIREC D300 and SIREC D400 • Number/Type 300 x 300 x 247 (11.34 x 11.34 x 9.72”) • 4 or 8 relay contacts SPDT, 3 A 240 V AC, 3 A 24 V AC/DC, 0.2A 240 V DC (non-inductive, internally suppressed) • 8 I/O or 16 I/O - SPNO, 1 A 24 V DC (non-inductive, internally suppressed) • Activation Fully programmable internal alarm levels. Assignable to any relay output • SIREC D300 138 x 138 mm (5.43 x 5.43”) Digital Input/Output • SIREC D400 281 x 281 mm (11.06 x 11.06”) • Quantity • 8 I/O or 16 I/O All channels may be selected freely as either digital inputs or outputs. The Digital I/O card also has 4 channels that can be set as pulse inputs (channels 1 … 4). The operating frequency for pulse inputs on the Digital I/O card is 1kHz max. • Relay Outputs • 4 relay outputs All four channels are relay outputs only • Relays/DI card • 8 relays/ 2 DI card 2 outputs can be configured for use as digital inputs: A digital input is provided by a volt free contact between the normally open (NO) and the common (C) terminals of an output relay. If the 2 Digital inputs are used only 6 relay outputs are available. Closed < 500 Ω, Open > 300 kΩ. Custom Screens Provides the capability in the recorder to accept custom screen designs from the Screen Designer. Email Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part of an Event occurring, such as: Alarms - In/Out/Ack, Totaliser – Start, Stop or Reset, Digital Inputs – On, Off or State change, TC Burnout – on a specific Analog Input channel, Scheduled Events – Once, Interval, Specific days, Month End OPC Server OPC 3.0 DA and AE compliant. Totalisers and up to 96 pens can be transmitted via OPC server, max poll rate 1/s Event marker User defined process events are recorded and can be set to cause particular recorder actions. Events can consist of recording start/stop, digital inputs, alarms, totalising actions, timers, barcode, etc. Once an event has been caused it can produce a definable set of effects on the recorder which can include, mark on chart, relay outputs, recording control, acknowledge alarm, trigger an Event, set/clear Relay, Screen change, E-mail a message and Reset max/mins. Each event marker can be recorded for analysis using the SIREC D application software. Analog Outputs (Re-transmission Outputs) Re-transmission outputs available; a pen drives each output. Analog inputs, totalised values or any mathematical result can be re-transmitted. Dimensions (W x H x D) in mm Additional 80 mm (3.15”) clearance recommended for a straight type power cable and signal connectors • SIREC D300 144 x 144 x 200 (5.67 x 5.67 x 7.87”) • SIREC D400 Cutout (W x H) in mm Weight • SIREC D300 Max. 3.5 kg (7.7lb) • SIREC D400 Max. 10 kg (22 lb) Wiring Connections IEC Power Plug. Removable terminal strip for input and alarm connections Environmental and Operating Conditions Ambient Temperature 0 °C … 50 °C (32 °F ... 122 °F) Relative Humidity (%RH) 10 ... 90 Vibration • Frequency (Hz) 0 ... 70 • Acceleration (g) 0.1 Mechanical Shock • Acceleration (g) 1 • Duration (ms) 30 Mounting Position from Vertical • Tilted Forward 40° • Tilted Backward 65° • Tilted to Side (±) 65° Power Requirements • Mains Voltage (Vrms) 100 … 250 • Low Voltage AC (Vrms) 20 … 30 • DC Voltages 20 … 55 • Frequency (Hz) 47 … 63 Power Consumption • SIREC D300 AC: < 40 W (max), DC: < 40 W (max). Typical 20 W • SIREC D400 AC: < 60 W (max), DC: < 60 W (max) . Typical 30 W Warm Up 30 minutes minimum Seismic Qualification Complies with IEEE 323-1974 and/or 1983 and IEEE 344-1975 and/or 1987 (optional) Options Pulse Input • Quantity 4 isolated inputs per board • Frequency 1 Hz … 25 kHz, updated once per second • Input Low < 1V, High > 4 V … < 50 V or Volt free input: Low = short circuit, High = open circuit. Alarm Outputs Programmable alarm set points (6 per pen) can be configured to activate up to 16 (SIREC D300) respectively 48 outputs (SIREC D400) • Update rate 200 ms for all alarms Modification 03/2008 Siemens MP 20 News · 2007 19 SIREC D Display Recorder SIREC D300 and SIREC D400 • Quantity - SIREC D300 2 or 4 re-transmission outputs - SIREC D400 2, 4, 6 or 8 re-transmission outputs • Update Rate 250 ms all channels • Accuracy ± 0.1% (0 … 500 Ω load), ± 0.25% (500 Ω, 1 kΩ load) • Type 0 … 20 mA, 4 … 20 mA • Maximum Load Resistance 1 kΩ • Resolution 0,002% • Isolation 300 V AC Health Watch/Maintenance Capability The recorder keeps track of important “life actions” for improved diagnostics and preventative maintenance notification. Including • Powered On • Last powered On • Time On since power up • Total On time • Total Off time • Longest Off time • Hardware/Firmware updates • Lithium cell life • Backlight life left at 100% brightness • Compact Flash insertions, • Hi/Lo CJC value (Hi & Lo temps), • Analog In last factory/user calibration • Relay operations Totaliser/Sterilisation One totaliser per input. Totaliser value must be assigned to a pen for display and storage. Multiple totalisations (Maths option) are possible with the use of extra pens (option). Reset may be manual or programmed. Totalisation values are 10 digits plus exponent. Each pen can be totalised according to the Fo or Po sterilisation function at 121.11°C (250 °F). The Standard Reference Temperature and Thermal Resistance (Z Value) are fully adjustable values of X, Y, W and V. Start temp, Reference temp and Z factor are all user defined, allowing support for many different types of sterilisation applications. Specification table for Sterilisation The definition of Fo/Po is the sterilisation/pasteurisation time in minutes required to destroy a stated number of organisms with a known z at temperature T. Batch The Batch function allows the user to segment portions of data for further analysis. Batch controls include • Start, • Stop, • Pause, • for viewing, • Resume and Abort. Print Support Network printing from status, message and replay screens. Plus screen capture facility of process screens instantly using a basic USB standard PCL printer. Math Algorithms All analog input channels have a math expression block. This is a fully user programmable 100 character free form math expression for each pen. Math calculations available on all pens, one per input plus 16 extra pens for the SIREC D300 and 48 extra pens for the SIREC D400 recorder. Scripting maths includes conditions and multi-line scripting in pen maths expressions. Allow functions, permanent variables and constants, timers. 500 characters maximum per pen. Miscellaneous Optional customer ID Tagging (3 lines of up to 22 characters each line) Agency Approval • CSA CSA22.2-No.1010.1-2004 Certificate Number L211230 • UL ANSI/UL61010-1-2004 File # 201698 FM Class 1 Division 2 (optional) Transmitter Power (optional) • SIREC D300 200 mA at 24 V DC ± 3 V DC • SIREC D400 1 A at 24 V DC ± 3 V DC Extended Security System (ESS) Provides full support for 21 CFR Part 11. Includes features for entry of unique User ID’s and associated passwords: • Timeout on inactivity (1 … 10 min) • Password expiration (1 … 365 days) • Up to 50 users • Password re-entry lock out for incorrect entry of password more than 3 times, no re-use of passwords (programmable 4 … 12 times) • Traceability by user name 20 Siemens MP 20 News · 2007 SIREC D Display Recorder SIREC D300 and SIREC D400 Firmware Credit System The credits system is a flexible way of adding to the recorder features without having to upgrade the firmware. Simply purchase a number of credits to cover your current and possibly future requirements and the recorder will be delivered with the credits loaded. The credit value in each recorder is displayed in the Factory menu. • Select the Options button and by activating and de-activating the options in the credit list, the recorder will change its functionality. Any greyed out options on the list will mean there are not enough credits available for that feature on the recorder. Credits can be applied as desired to the Firmware functions until the total number of credits purchased has been used up. Additional credits can be purchased later if new features are to be activated and not enough credits are available to support these additional functions. Firmware option Credit value Description Full Maths 4 Full Math - this can handle math expressions that can consist of expressions up to 100 characters in length. (Note 1) Full Maths with Scripting 6 A powerful multi-line scripting ability available to solve complex state based applications. Eg.: “If .. X happens, then Y will happen, else.. Z will occur. (Note 1) Events 6 Events are certain conditions or operations that can be set up and logged according to the time and date of an occurrence. Subsequently events can be reviewed or displayed on a graph. Events can produce the following actions: Mark on Chart, start/stop Logging, Start/stop/reset Totalisers, Set/clear Relay (Digital), Acknowledge alarm, trigger an Event, Screen change, E-mail a message and Reset max/mins. (Note 3) Fast Scanning mode 5 For fast processes, the scan rate and recording of the data can be set for up to 50 times per second (20 ms) for • SIREC D300: up to 8 inputs • SIREC D400: up to 16 inputs Totalisers/ Sterilisation calcu- 4 lation Each pen can be associated with a totaliser. Using extra pens, the totalised values can be displayed and recorded; multiple totals can be calculated out of the same variable (weekly, monthly, etc.). The totaliser function can handle Fo and Po sterilisation calculation. (Note 1) Custom Screens 4 Import custom built screens that have been created in SIREC D-Designer. (Note 2) Health Watch/ Maintenance 2 The recorder keeps track of important “life actions” for improved diagnostics and preventative mainte-nance notification. Including Powered On, Last powered On, Time On since power up, Total On time, Total Off time, Longest Off time, Lithium cell life, Backlight life left at 100% brightness, Compact Flash insertions, Hi/Lo CJC value (Hi & Lo temps), Analog In last factory/user cal, Relay operations Print Support 2 Enables the printer option to print text from various screens using a basic USB standard PCL printer. Batch 3 The Batch function allows the user to segment portions of data for further analysis. Batch controls include Start, Stop, Pause, for viewing, Resume and Abort. Groups 2 Groups of Pens can be specified and named with a Group number to display on the recorder. Remote Viewer 3 Extends the user interface of the recorder onto the desktop PC. Providing full remote control of the unit launched from a web browser. Email 3 Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part of an Event occurring, such as: Alarms - In/Out/Ack, Totaliser – Start, Stop or Reset, Digital Inputs – On, Off or State change, TC Burnout – on a specific Analog Input channel, Scheduled Events – Once, Interval, Specific days, Month End. OPC Server 8 OPC (OLE for Process Control) -Software application for realtime interfacing between servers and cli-ents. OPC is a software standard that defines common interfaces for data exchange between devices such as recorders, controllers, PLC’s and Microsoft Windows™ based applications Extra Pens (4) 2 4 extra pens to store and display totalised values, results of calculations, etc. • SIREC D300: Maximum is up to 16 extra pens • SIREC D400: Maximum is up to 48 extra pens Notes • (1) Additional pens (“Extra Pens”) can be used to display and store the results of calculations, totalisers, variables imported via communications, or to store values. • (2) Screens from Screen Designer for SIREC D300 and SIREC D400 cannot be imported. • (3) Event markers are required to automatically reset the totalisers, for example on a periodic basis or on an external condition. (Not necessary if the totalisers are reset manually). Additional information is available in the Internet under: http://www.siemens.com/sirec Siemens MP 20 News · 2007 21 SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Selection and Ordering Data Order No. ■ Selection and Ordering Data Order No. SIREC D300 display recorder 1) 7ND4421- SIREC D300 display recorder 1) 7ND4421- Front dimensions: 144 mm x 144 mm, for all applications, Cycle time: 200 ms for mA,V,mV/500 ms for TC/RTD/R Rear side: Ethernet interface; RS485; USB Front face: slot for CF card; USB interface 7 7 A 7 7 - 7 7 7 7 Front dimensions: 144 mm x 144 mm, for all applications, Cycle time: 200 ms for mA,V,mV/500 ms for TC/RTD/R Rear side: Ethernet interface; RS485; USB Front face: slot for CF card; USB interface 7 7 A 7 7 - 7 7 7 7 Power supply Firmware options (see table below " Firmware options and required credits") 50 or 60 Hz, 90 ... 240 V AC • without transmitter power supply } 1 • 24 V DC max. 200 mA transmitter power supply None 2 } A 10 credits B 20 credits C 30 credits D Analog inputs/ Pulse inputs 40 credits E 8 analog inputs 50 credits F A 60 credits G • 2 analog outputs B Protection rating standard (front face) • 4 analog outputs C IP54 14 analog inputs, without analog outputs D • without earthquake-proof version 16 analog inputs, without analog outputs E IP66 (NEMA 4X) 24/48 V DC / 24 V AC, 50/60 Hz, without transmitter power supply • without analog outputs 4 } 4 pulse inputs } A • without earthquake-proof version D • without analog outputs H • Earthquake-proof version E • 2 analog outputs J Documentation • 4 analog outputs K Manual in German • 8 analog inputs, without analog outputs L Manual in English 8 pulse inputs, without analog outputs M 1) } 0 4 relays (240 V) 1 8 relays, of which 2 can be optionally configured as binary input (240 V) 2 8 binary outputs and inputs (24 V relay/freely-configurable) 3 16 binary outputs and inputs (24 V relay/freely-configurable) 4 } 1 180 Mbyte 2 400 Mbyte 3 890 Mbyte 4 1850 Mbyte 5 Extended Security System (ESS) } None With 22 1 2 Siemens MP 20 News · 2007 2 Subject to export regulations AL:N, ECCN: EAR99 Scope of delivery: Recorder, CD-ROM with manual in German or English, SIREC D software (SIREC D-Viewer). Note: CF card is included in the scope of delivery. Internal data storage 70 Mbyte (standard) 1 } Available ex stock Switching outputs and inputs None } SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. SIREC D400 display recorder 1) Front dimensions: 300 mm x 300 mm, for all applications 7ND44617 7 7 7 7 - 7 7 7 7 Order No. SIREC D400 display recorder 1) Front dimensions: 300 mm x 300 mm, for all applications Power supply Internal data storage 50 or 60 Hz, 90 ... 240 V AC 70 Mbyte (standard) 7ND44617 7 7 7 7 - 7 7 7 7 } 1 } 1 180 Mbyte 2 • 24 V DC max. 200 mA transmitter power supply 2 400 Mbyte 3 890 Mbyte 4 24/48 V DC / 24 V AC, 50/60 Hz, without transmitter power supply 4 1850 Mbyte 5 • without transmitter power supply Analog inputs (slot allocation 1 … 4) Extended Security System (ESS) 16 analog inputs None 1 • without pulse inputs A With 2 • 4 pulse inputs B • 8 pulse inputs C Firmware options (see table "Firmware options and required credits") } 24 analog inputs } None A • without pulse inputs D 10 credits B • 4 pulse inputs E 20 credits C 32 analog inputs, without pulse inputs F 30 credits D 40 credits E without analog inputs • 4 pulse inputs G 50 credits F • 8 pulse inputs H 60 credits G • 12 pulse inputs J 70 credits H • 16 pulse inputs K Protection rating standard (front face) IP54 Analog inputs/Pulse inputs (slot allocation 5 and 6) • without earthquake-proof version without analog inputs • without analog outputs A IP66 (NEMA 4X) } A • 2 analog outputs B • 4 analog outputs C • without earthquake-proof version D • Earthquake-proof version E Documentation 8 analog inputs Manual in German • without analog outputs D • 2 analog outputs F 16 analog inputs, without analog outputs G } } 1 Manual in English 2 } Available ex stock 1) Switching outputs and inputs (distributed on 3 slots) None } 0 4 relays (240 V) 1 8 relays, of which 2 can be optionally configured as binary input (240 V) 2 16 relays, of which 4 can be optionally configured as binary input (240 V) 3 24 relays, of which 6 can be optionally configured as binary input (240 V) 4 8 binary outputs and inputs (24 V relay/freely-configurable) 5 16 binary outputs and inputs (24 V relay/freely-configurable/ 1 x 16) 6 24 binary outputs and inputs (24 V relay/freely-configurable/16 + 8) 7 48 binary outputs and inputs (24 V relay/freely-configurable/3 x 16) 8 Subject to export regulations AL:N, ECCN: EAR99 Scope of delivery: Recorder, CD-ROM with manual in German or English, SIREC D software (SIREC D-Viewer). Note: CF card is included in the scope of delivery. Modification 03/2008 Siemens MP 20 News · 2007 23 SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Accessories Firmware options and required credits Order No. SIREC D300 Firmware options for SIREC D300 and SIREC D400 Code No. of recorder required Options 10 credits 7ND4 801-8AC 20 credits 7ND4 801-8BC 30 credits 7ND4 801-8CC 40 credits 7ND4 801-8DC 50 credits 7ND4 801-8EC 60 credits 7ND4 801-8FC 70 credits (SIREC D400 only) 7ND4 801-8GC Options/enabling of SIREC D software Code No. of software required Required credits Groups/summarize channels 2 Diagnostic functions 2 Print support 2 4 extra pens (virtual channels) 2 8 extra pens (virtual channels) 4 16 extra pens (virtual channels) 8 Counter 2 Remote viewer 3 Batch 3 E-mail function 3 Enabling of SIREC D-Manager 7ND4 800-8BA Totalisers 4 Enabling of SIREC D-Server 7ND4 800-8CA Maths (free functions) 4 Enabling of SIREC D-Designer (only for SIREC D300 and SIREC D400) 7ND4 801-8DA Maths and Scripts (free functions) 6 Events (logical connections) 6 Upgrading of SIREC D-Manager to SIREC D-Server 7ND4 800-8EA OPC Interface 8 Custom specified screens 4 SIREC D software Only for subsequent orders; software is included in delivery of recorder Evaluation software for SIREC D200/D300/D400 (on CD) incl. enabling for SIREC D-Viewer and manual for the software on CD in German, English, French 7ND4 800-8AA Fast scanning (20 ms/only with mV/V/mA) 5 SIREC D400 Options Required credits Groups/summarize channels 2 Diagnostic functions 2 Documentation Included on CD-ROM in scope of delivery Print support 2 4 extra pens (virtual channels) 2 SIREC D300 and SIREC D400 recorder manual 8 extra pens (virtual channels) 4 16 extra pens (virtual channels) 8 32 extra pens (virtual channels) 16 48 extra pens (virtual channels) 24 Counter 2 • French (can only be downloaded from Internet) Remote Viewer 3 Batch 3 Scope of delivery: Recorder, CD-ROM with manual in German or English, SIREC D software (SIREC D-Viewer). Note: CF card is included in the scope of delivery. E-mail function 3 Full Maths 4 Maths (free functions) 4 Maths and Scripts (free functions) 6 • German (can also be downloaded from Internet) A5E01001785 • English (can also be downloaded from Internet) A5E01001767 24 Siemens MP 20 News · 2007 Events (logical connections) 6 OPC Interface 8 Custom specified screens 4 Fast scanning (20 ms/only with mV/V/mA) 5 Modification 07/2007 SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Options Options - Hardware • Alarm Card - 4 or 8 outputs relay contacts SPCO 240 V - 8 Digital I/O or 16 Digital I/O - SPNO 24 V DC - Programmable alarm set points can be configured to activate up to 16 outputs for the SIREC D300 and 48 outputs for the SIREC D400. • Analog Output - 2 or 4 outputs available per card - Output type: 0-20 mA or 4-20 mA • Nema 4X/IP66 - Nema 4X/IP66 protection available as an option. • Portable Recorders - Portable cases available as an accessory item. • Digital Input Two digital input options are available: - 2 inputs on 8 channel Alarm card, 8 inputs on 8 Digital I/O card and 16 inputs on a 16 Digutal I/O card. The digital inputs allow users to initiate, from a remote location via a dry contact closure, selected recorder functions. • Pulse Counting - Up to four counting inputs per board, are available to count signals up to 25 kHz (SIREC D300: max. 2 cards; SIREC D400: max. 6 cards). • Approvals - CSA, UL and FM CL1 Div 2 approvals • 24 V AC/DC or 48 V DC Power Supply - 20 to 55 V DC - 20 to 30 V AC • 24 V DC Transmitter Power Supply - Can supply up to 200 mA (SIREC D300) respectively 1 A (SIREC D400) to external transmitters. • Print Support - Network printing from status, message and replay screens. Plus screen capture facility of process screens instantly using a basic USB standard PCL printer. ■ Dimensional drawings 156.92 (6.178) 80 (3.150) 200 (7.874) 37 (1.457) 137.5 (5.413) 144,01 (5.670) 144.01 (5.670) Two mounting brackets are supplied as standard 138.00 (5.43”) Panel Cut-out Panel Cut-out +1 -0 138.00 (5.43”) +1 -0 > 7.00 (0.28”) > 6.00 (0.237”) Panel Cut-out SIREC D300 Recorder Panel Cut-Out SIREC D300, dimensions in mm (inch) and panel cut-out Siemens MP 20 News · 2007 25 SIREC D Display Recorder SIREC D300 and SIREC D400 200 (7.874) 47 (1.850) Two mounting brackets are supplied as standard 281.00 (11.06”) Panel Cut-Out Panel Cut-Out Panel Cut-Out SIREC D400, dimensions mm (inch) and panel cut-out Siemens MP 20 News · 2007 281 (11.06”) > 20,00 (0.787”) > 20.00 (0.787”) 26 80 (3.150) 280 (11.024) 300 (11.811) 300 (11.811) SIREC D400 Recorder Panel Cut-Out SIREC D Display Recorder SIREC D300 and SIREC D400 ■ Schematics CJC Connector position Slot A Slot B 24 V TX Power Supply 2-way connector Analogue Input - Slots A and B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CJC - +* -+ * - +* - +* -+* -+ * -+* -+ * Slot G 4 and 8 Relay Alarm - Slot G 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Analogue Output - Slot B only 1 2 3 4 5 6 7 8 9 10 11 12 NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO (Last 2 channels can be Digital Inputs on 8 Alarm Relay card) + + NU NU Loop Loop Loop Loop + + NU NU Loop Loop Loop Loop Pulse Input - Slots A & B (Connector position on right hand side) 8 and 16 Digital Input/Output - Slot G 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C 24 V Transmitter Power Supply 13 14 15 16 17 18 19 20 21 22 23 24 - + NU - + NU - + NU - + NU This is already fitted to the power supply card within the recorder. Connection is made via a 2-way connector at rear of unit Key: NO = Normally Open, C = Common , NC = Normally Closed, NU = Not Used SIREC D300 - Terminal assignments and power requirements (rear of unit) Siemens MP 20 News · 2007 27 SIREC D Display Recorder SIREC D300 and SIREC D400 Slot A Slot B Slot C Slot D Slot E Slot F 24 V TX Power Supply CJC Connector position Analogue Input - Slots A to F 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CJC - +* - +* - +* - +* - +* - +* - +* - +* Slot G Slot H Slot I Analogue Output - Slots E and F 4 and 8 Relay Alarm - Slots G to I 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO 1 2 3 4 5 6 7 8 9 10 11 12 (Last 2 channels can be Digital Inputs on the 8 Alarm Relay card) 8 and 16 Digital Input/Output - Slots G to I + NU NU + Loop Loop Loop Loop + + NU NU Loop Loop Loop Loop Pulse Input - Slots A to F 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C (Connector position on right hand side) 13 14 15 16 17 18 19 20 21 22 23 24 24 V Transmitter Power Supply Connection is made via two 10-way connector at rear of unit Key: NO = Normally Open , C = Common , NC = Normally Closed, NU = Not Used - + NU - + NU - + NU - + NU SIREC D400 - Terminal assignments and power requirements (rear of unit) ■ More information Additional information is available in the Internet under: http://www.siemens.com/sirec 28 Siemens MP 20 News · 2007