Datasheet ACT20M Signal Isolation and Conversion NEW Weidmuller’s new 8-pole housing, module power can be distributed through the rail for minimized power wiring and reduced installation costs. This “Power Rail” provides the flexibility to add or remove individual modules quickly and easily without affecting the wiring or operation of other components on the rail. The ACT20M range offers two-channel loop-powered isolation, signal splitting with power provided for the transmitter, or universal input conversion in a 6mm wide module — without compromising performance. In addition, configuration is simple because the ACT20M modules require no calibration. Models with selectable voltage and current ranges feature DIP switches. For the Universal input model, Weidmuller provides vendor-independent, FDT-based configuration software available for download from the Weidmuller website. High quality signal isolation and conversion in a slim 6mm wide housing format is now available with Weidmuller’s ACT20M range. Featuring worldwide approvals for both standard and hazardous area installations, this series of eight single- and dual-channel models extends Weidmuller’s signal conditioning portfolio with a package of solutions for industrial process measurement and control applications. ACT20M is designed to reduce the time and cost of building control panels. DIN-rail mounted in Features: • Very high density analog signal isolation and conversion • Easy installation with Power Rail cross-connect option • DIP switches for calibration-free re-ranging • Universal input model uses FDT configuration software (and CBX200 interface) • CE, cULus, cFMus Class 1 Div. 2 and Class 1 Zone 2 ATEX, IECEx Zone 2, DNV, GL approvals • Ambient temperature range typically -13˚F to 158˚F (-25˚C to 70˚C) Weidmuller, Canada Weidmuller, Mexico Weidmuller, United States 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Blvd. Hermanos Serdán 698 Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com Signal Isolation and Conversion Universal input converter ACT20M ACT20M-UI-AO-S • Isolating and converting of temperature signals and DC signals • Configuration using FDT/DTM software • Optional power supply via the DIN-rail-bus • 3 way isolation 4 3 I, U, R IN 2 5 I, U 6 OUT 7 1 82 83 Supply 8 Supply Technical data Input Sensor Thermocouples: B, E, J, K, L, LR, N, R, S, T, U, W3, W5 RTD: PT100, PT1000, Ni120, Ni100, Ni1000 2/3/4 conductor Potentiometer/Resistance Input current Input voltage Load resistance, current Load resistance, voltage 10 Ω…10 k Ω 0/4...20 mA 0/2...10 V < 75 Ω > 500 k Ω Sensor supply Output Output current > 15 V DC at 20 mA Output voltage Load resistance, current 0/2…10 V < 600 Ω Load resistance, voltage General data Supply voltage > 10 k Ω Power consumption 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C 0/4…20 mA 24 V DC ± 30 % Ambient temperature (operational) Storage temperature Accuracy < 0.1 % span (DC, RTD) < 0.2 % + CJ error (TC) Temperature coefficient Insulation coordination Insulation voltage < 0.01 % /K Rated voltage Pollution degree 300 V 2 Overvoltage category Approvals II 2.5 kV cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL Dimensions Length x width x height Clamping range (nominal / min. / max.) mm mm2 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 Note Ordering data Type ACT20M-UI-AO-S Qty. 1 Part No. 1176030000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Note Accessories Marker USB interface Note 2 CBX200 USB DIN-rail bus, refer to accessories page 8978580000 Signal splitter • • • • ACT20M-CI-2CO-S ACT20M-AI-2AO-S Isolating, converting and splitting DC signals Configured using DIP switch Optional power supply via the DIN-rail bus 4 way isolation I IN I OUT 2 4 2 1 I, U 4 5 I, U 6 IN 3 6 OUT 1 7 I, U 2 OUT 2 1 5 3 82 83 I OUT 1 Supply 8 7 82 83 Supply 8 Supply Supply Technical data Input Input current 0/4…20 mA 0/4…20 mA Input voltage – 0/2…10 V 0/1…5 V Load resistance, current Load resistance, voltage < 75 Ω – < 75 Ω > 500 k Ω Sensor supply Output Output current – > 17 V DC at 20 mA 0/4…20 mA 0/4…20 mA Output voltage – 0/2…10 V 0/1…5 V Load resistance, current < 300 Ω / channel < 300 Ω / channel > 10k Ω / channel Load resistance, voltage General data Supply voltage Power consumption Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Cut-off-frequency Insulation coordination Insulation voltage Rated voltage Pollution degree Overvoltage category Approvals Dimensions Length x width x height Clamping range (nominal / min. / max.) mm mm2 24 V DC ± 30 % 24 V DC ± 30 % 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % /K 0.4W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % /K 100 Hz 100 Hz 2.5 kV 300 V 2 2.5 kV 300 V 2 II II cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL 114.3 x 6.1 x 112.5 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 2.5 / 0.5 / 2.5 Note Ordering data Type ACT20M-CI-2CO-S Qty. Part No. Type 1 1175990000 ACT20M-AI-2AO-S Qty. Part No. 1877680000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1 1176020000 Qty. Part No. 1877680000 Note Accessories Marker Note Type MF 5/7.5 MC NEUTRAL DIN-rail bus, refer to accessories page DIN-rail bus, refer to accessories page 3 Signal Isolation and Conversion Converters for DC mA and Volts • • • • • ACT20M ACT20M-AI-AO-S ACT20M-AI-AO-E-S Isolating and converting DC signals DIP switch for range changes without re-calibration Optional power supply via the DIN-rail-bus 3 way isolation Choice of active or passive mA input (“E“ model is passive only) I, U IN 4 5 3 6 2 I, U I, U 4 OUT IN 3 2 7 1 82 83 8 82 Supply I, U 6 OUT 7 1 Supply 5 83 8 Supply Supply Technical data Input Input current 0/4…20 mA 0/4…20 mA Input voltage 0/2…10 V 0/1…5 V 0/2…10 V 0/1…5 V Load resistance, current Load resistance, voltage < 75 Ω > 500 k Ω < 75 Ω > 500 k Ω Sensor supply Output Output current > 17 V DC at 20 mA – 0/4…20 mA 0/4…20 mA Output voltage 0/2…10 V 0/1…5 V < 600 Ω 0/2…10 V 0/1…5 V > 10 k Ω > 10 k Ω 24 V DC ± 30 % 24 V DC ± 30 % 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % /K 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) 0 °C…+70 °C -40 °C…+85 °C < 0.2 % of measurement range < 0.015 % /K Cut-off-frequency Insulation coordination Insulation voltage 100 Hz 100 Hz 2.5 kV 2.5 kV Rated voltage Pollution degree 300 V 2 300 V 2 Overvoltage category Approvals II II cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL cULus 61010-1, DNV, GL 114.3 x 6.1 x 112.5 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 2.5 / 0.5 / 2.5 Load resistance, current Load resistance, voltage General data Supply voltage Power consumption Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Dimensions Length x width x height Clamping range (nominal / min. / max.) mm mm2 < 600 Ω Note Ordering data Type ACT20M-AI-AO-S Qty. 1 Part No. 1176000000 Type ACT20M-AI-AO-E-S Qty. 1 Part No. 1176010000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Note Accessories Marker Note 4 DIN-rail bus, refer to accessories page DIN-rail bus, refer to accessories page ACT20M Signal Isolation and Conversion ILP and OLP isolators ACT20M-CI-CO-ILP-S ACT20M-CI-CO-OLP-S • Isolation of DC mA signals • Takes power from the input loop (ILP) or output loop (OLP) • Available as either single-channel or double-channel version • 2 way isolation I IN 1 I IN 2 4 5 3 6 2 7 1 8 I OUT 1 I IN 1 I OUT 2 I IN 2 4 5 3 6 2 7 1 8 I OUT 1 I OUT 2 Technical data Input Input current 0/4…20 mA 0/4…20 mA Load resistance, current – < 75 Ω Voltage drop Output Output current ≤ 1.2 V – 0/4…20 mA 4 - 20 mA Load resistance, current General data Power consumption < 600 Ω < 600 Ω 30 mW per channel - from input loop -25 °C…+70 °C -40 °C…+85 °C < 0.1 % of measurement range < 0.01 % /K 55 mW per channel - from output loop -25 °C…+70 °C -40 °C…+85 °C < 0.1 % of measurement range < 0.01 % /K Cut-off-frequency Insulation coordination Insulation voltage 100 Hz 100 Hz 2.5 kV 2.5 kV Rated voltage Pollution degree 300 V 2 300 V 2 Overvoltage category Approvals II II cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL 114.3 x 6.1 x 112.5 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 2.5 / 0.5 / 2.5 Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Dimensions Length x width x height Clamping range (nominal / min. / max.) mm mm2 Note Ordering data Single-channel version Double-channel version Type ACT20M CI-CO-ILP-S ACT20M 2CI-2CO-ILP-S Qty. 1 Part No. 1176070000 Type ACT20M- CI-CO-OLP-S 1 1176080000 ACT20M-2CI-2CO-OLP-S Qty. Part No. 1877680000 Type MF 5/7.5 MC NEUTRAL Qty. 1 Part No. 1176040000 1 1176050000 Qty. Part No. 1877680000 Note Accessories Marker Type MF 5/7.5 MC NEUTRAL Note 5 Signal Isolation and Conversion DC isolator ACT20M ACT20M-CI-CO-S • Isolating DC signals • Optional power supply via the DIN-rail-bus • 3 way isolation I IN 4 5 3 I OUT 6 2 7 1 82 83 8 Supply Supply Technical data Input Input current 0/4…20 mA Load resistance, current Output Output current < 75 Ω Load resistance, current General data Supply voltage Power consumption < 600 Ω 0/4…20 mA 24 V DC ± 30 % 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % span/K Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Cut-off-frequency Insulation coordination Insulation voltage 100 Hz Rated voltage Pollution degree 300 V 2 Overvoltage category Approvals II 2.5 kV cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL Dimensions Length x width x height Clamping range (nominal / min. / max.) mm mm2 114.3 x 6.1 x 112.5 mm 2.5 / 0.5 / 2.5 mm² Note Ordering data Type ACT20M-CI-CO-S Qty. 1 Part No. 1175980000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Note Ordering data Marker Note 6 DIN-rail bus, refer to accessories page ACT20M Signal Isolation and Conversion Rail bus accessories Preliminary product data! CH20M BUS-PROFIL TS35x7.5/1000 CH20M BUS-PROFIL TS35x15/1000 CH20M BUS 4.50/05 AU/1000 Support section for bus PCB Support section for bus PCB Bus PCB • Support section for TS35 x 7.5 • Length: 250, 500 or 750 mm • Support section for TS35 x 15 • Length: 250, 500 or 750 mm • Bus PCB for use on TS35 x 7.5 and TS 35 x 15 • Length: 250, 500 or 750 mm • Five conductor paths, gold plated • Electrical rating: 63 V AC, 5 A/conductor path Ordering data Ordering data Ordering data Type CH20M BUS-PROFIL TS35x7.5/250 Qty. Part No. 10 1248150000 Type CH20M BUS-PROFIL TS35x15/250 Qty. Part No. 5 1248180000 Type CH20M BUS 4.50/05 AU/250 Qty. Part No. 10 1248220000 CH20M BUS-PROFIL TS35x7.5/500 10 1248160000 CH20M BUS-PROFIL TS35x15/500 5 1248190000 CH20M BUS 4.50/05 AU/500 10 1248230000 CH20M BUS-PROFIL TS35x7.5/750 5 1248170000 CH20M BUS-PROFIL TS35x15/750 5 1248210000 CH20M BUS 4.50/05 AU/750 5 1248240000 CH20M BUS-ADP TS35/1000 CH20M BUS-AP LI TS35x7.5 & 15 CH20M BUS-AP RE TS35x7.5 & 15 Cover plate End plate End plate • Cover plate for rail bus • Length: 250, 500 or 750 mm • End plate for rail bus • Fits on TS35 x 7.5 and TS 35 x 15 • Left • End plate for rail bus • Fits on TS35 x 7.5 and TS 35 x 15 • Right Ordering data Ordering data Ordering data Type CH20M BUS-ADP TS35/250 Qty. Part No. 10 1248250000 CH20M BUS-ADP TS35/500 10 1248260000 CH20M BUS-ADP TS35/750 5 1248270000 Type CH20M BUS-AP LI TS35x7.5 & 15 Qty. Part No. 50 1193160000 Type CH20M BUS-AP RE TS35x7.5 & 15 Qty. Part No. 50 1193170000 7 Signal Isolation and Conversion ACT20 power feed module • • • • • • ACT20M ACT20-Feed-In-PRO-S ACT20-FEED-IN-BASIC-S istributes the voltage supply on the busbar D Compatible with Weidmuller‘s CH20 rail bus Optional backup supply connection Approved for installation in Ex Zone 2 /Div. 2 Monitors the supply voltage Alarm alerts via the status relay Alarm Power supply, 0 V 51 44 NC Power supply, +24 V 52 Power supply, +24 V 43 Status relay, N.C. Backup, +24 V 53 42 Status relay, shared Backup, 0 V 54 41 Status relay, N.O. NC 0V +24 V 81 NC 82 NC 83 Status 0V 84 +24 V NC NC 85 Power supply, 0 V Technical data Input Power supply 21.6...26.4 V DC 16.8...31.2 V DC Max. input current Backup power supply 4A 21.6...26.4 V DC 2.5A Trigger level for the power supply Output, power supply Output voltage Fault < 21 V DC Input voltage -0.5 V DC @ 4 A = U input Output power max. 96 W = P input Output current Output, status relay in safe zone Max. voltage max. 4 A = I input Max. current 2 A AC / 2 A DC Max. AC power General data Efficiency degree 500 VA / 60 W > 97.9 % 100 % Ambient temperature Storage temperature Power consumption Protection degree Weight Humidity Approvals -20...+60 °C -20...+85 °C -25...+70 °C -40...+85 °C <2W IP20 140 g < 95 %, no condensation cULus, cULus EX, ATEX, IECEx Zone 2, DNV*, GOST*, CE <2W IP20 70 g < 95 %, no condensation cULus, ATEX, IECEx Zone 2, GL, DNV, CE mm Screw connection 2.5 / 0.5 / 2.5 Screw connection 2.5 / 0.5 / 2.5 mm2 119.2 / 22.5 / 113.6 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Length x width x height Note 250 AC / 30 V DC * applied for Ordering data Type ACT20-Feed-In-PRO-S Qty. 1 Part No. 8965500000 Type ACT20-FEED-IN-BASIC-S Qty. 1 Part No. 12824900000 Note Accessories Note 8 Subject to technical changes • 03/12-LIT1126E