PT5MA

PT5MA
Industrial Grade • 0...5, 0...10 Vdc
Absolute Linear Position to 250 inches (6350 mm)
Hard Anodized Aluminum Enclosure
High Cycle Applications
IP67 • NEMA 6 Protection
GENERAL
Full Stroke Range Options
Output Signal Options
Accuracy
0-10 to 0-250 inches
4...20 mA (2-wire) and 0...20 mA (3-wire)
± 0.75% to ±0.18% full stroke (see ordering information)
Repeatability
see ordering information
Resolution
essentially infinite
Measuring Cable Options
Enclosure Material
hard anodized aluminum
Sensor
plastic-hybrid precision potentiometer
Potentiometer Cycle Life see ordering information
Maximum Measuring Cable Velocity
see ordering information
Maximum Retraction Acceleration
see ordering information
Weight
5 lbs. max.
ELECTRICAL
Input Voltage
see ordering information
Input Current
20 mA max.
Maximum Loop Resistance (Load)
4.0” [102 mm]
The PT5MA potentiometric cable-extension transducer
uses a unique thermoplastic cable that has virtually an infinite fatigue life. This cable, known as V62, has properties
that are superior for high cycle and rugged applications.
Like Celesco’s other transducers, the PT5MA installs in minutes, functions properly without perfectly parallel alignment, and fits easily into small areas. The PT5MA offers
additional installation flexibility since its cable exit can be
rotated relative to the mounting surface, providing four different cable exit orientations.
(loop supply voltage – 8)/0.020
Circuit Protection
Impedance
6.8” [173 mm]
stainless steel or thermoplastic
38 mA max.
Output Signal:
100 M ohms @ 100 VDC, min.
Signal Adjust, Zero
from factory set zero to 50% of full stroke range
Signal Adjust, Span
to 50% of factory set span
ENVIRONMENTAL
4...20 mA*
(0% fs.)
Enclosure
(100% fs.)
NEMA 4/6, IP 65/67
Operating Temperature
Vibration
-40° to 200°F (-40° to 90°C)
up to 10 G’s to 2000 Hz maximum
EMC COMPLIANCE PER DIRECTIVE 89/336/EEC
Emission / Immunity
*Optional 3-wire, 0...20mA output signal available.
EN50081-2 / EN50082-2
20630 Plummer Street • Chatsworth, CA 91311
tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799
meas-spec.com
PT5MA | 1
Outline Drawing:
0.69 [17,5]
5.32 [135,0]
A DIMENSION (inches[mm])
eyelet detail
.165 [4,19]**
3.50 [88,9]
4.00 [101,6]
Ø.191 [4,19]*
Ø.375 [9,52]**
0.67 [17,0]
cable fully retracted
cable fully extended
N34
RANGE
10
15
20
30
40
50
60
80
100
125
150
200
250
S47 & V62
measuring cable
measuring cable
0.05 [1,2]
0.07 [1,8]
0.09 [2,4]
0.14 [3,5]
0.19 [4,7]
0.23 [5,9]
0.28 [7,0]
0.37 [9,4]
0.46 [11,7]
0.58 [14,7]
0.69 [17,6]
0.92 [23,5]
1.16 [29,3]
0.08 [2,0]
0.12 [3,0]
0.16 [3,9]
0.23 [5,9]
0.31 [7,9]
0.39 [9,9]
0.47 [11,8]
0.62 [15,8]
0.78 [19,7]
0.97 [24,7]
1.16 [29,6]
n/a
n/a
0.28 [7,1]
see detail
A
1.06 [26,9]
0.70 [17,8]
3.19 [81,0]
0.21 [5,3]
2.19 [55,6]
0.19 [4,8]
6.8 [172,6]
DIMENSIONS ARE IN INCHES [MM]
tolerances are 0.03 IN. [0.5 MM] unless otherwise noted.
* tolerance = +.005 –.001 [+.13 –.03]
** tolerance = +.005 –.005 [+.13 –.13]
Ordering Information:
Model Number:
Sample Model Number:
PT5MA order code:
Full Stroke Range:
10
R order code:
full stroke range, min: 10 in.
accuracy (±% of f.s.): .75%
repeatability (±% of f.s.): .1%
potentiometer cycle life:
cable tension (20%):
max. cable velocity/acceleration:
PT5MA - 100 - N34 - FR - 420E - M6
R
-
A
15
20
25
15 in. 20 in. 25 in.
.6%
.5%
.5%
.1%
.05% .05%
2,500,000 cycles
B
30
30 in.
.5%
.05%
C
-
40
40 in.
.3%
.05%
41 ounces
300 in./sec • 5 g
D
50
50 in.
.3%
.05%
R
A
B
C
D
range:
measuring cable:
cable exit:
output signal:
electrical connection:
60
80
60 in. 80 in.
.25% .25%
.02% .02%
500,000 cycles
100 inches
.034 nylon-coated stainless
front
4...20 mA
6-pin plastic connector
100
125
150
200
250
100 in. 125 in. 150 in. 200 in. 250 in.
.25% .25% .18% .18% .18%
.02% .02% .02% .02% .02%
250,000 cycles
21 ounces
120 in./sec • 2 g
tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799
meas-spec.com
2 | PT5MA
Ordering Information (cont.):
Measuring Cable:
N34
A order code:
.034 nylon-coated stainless steel
available in all ranges
S47
V62
.047 stainless steel
all ranges up to 150 inches
.062 thermoplastic
all ranges up to 150 inches
0.047 in.
(1,19 mm) dia.
0.034 in.
(0,86 mm) dia.
B order code:
0.062 in.
(1,57 mm) dia.
0.170 in. (4,32 mm)
0.170 in. (4,32 mm)
Cable Exit:
Ø.190 in. (4,83 mm) thru
Ø.190 in. (4,83 mm) thru
Ø.190 in. (4,83 mm) thru
0.170 in. (4,32 mm)
UP
DN
FR
BK
up
down
front
back
.46 [11,7]
4.23
[107,4]
.85 [21,6]
.40 [10.2]
2.98 [75,7]
0.79 [20,1]
.79 [20.1]
.46 [11,7]
Output Signals:
C order code:
output signal options:
inches [mm]
420E
420R
020E
020R
4...20 mA
20...4 mA
0...20 mA
20...0 mA
20
4
sensitivity:
wiring configuration:
input voltage:
20
4
20
0
16 mA/full stroke ±0.25%
2 – wire
8 – 34 vdc
20
0
20 mA/full stroke ±0.25%
3 – wire
14 – 29 vdc
example:
4 mA =
ordercode = 420E = 4...20 mA
20 mA =
Electrical Connection:
M6M
MC4
C25
6-pin plastic connector
with mating plug
M6
6-pin metal connector
with mating plug
4-pin micro-connector
with 12 ft [3.5 M] cordset
25-ft. instrumentation cable
24 AWG, shielded
IP 67, NEMA 6
IP 65, NEMA 4
IP 67, NEMA 6
IP 67, NEMA 6
D order code:
3.0 in.
[78 mm]
.30 – .39 in. [8 – 10 mm] cable dia.
16 AWG max conductor size
connector: MS3102E-14S-6P
mating plug: MS3106E-14S-6S
2.4 in.
[60 mm]
.375 in. [9 mm] max cable dia.
16 AWG max conductor size
connector: MS3102E-14S-6P
mating plug: MS3106E-14S-6S
6-pin mating plug:
A
F
B
E
C
D
contact view
pin
A
B
C
D
1.2 in. [31 mm]
12 ft. x 5/16-in. dia.
[3,5 M x 8 mm dia.]
yellow PVC jacket
shielded, 22 AWG
25 ft. x 0.2-in. dia.
[7,5 M x 5 mm dia.]
24 AWG, shielded
4-pin mating plug and cordset:
2-wire
8...34 vdc
4...20 mA
earth ground
3-wire
14...29 vdc
common
0...20 mA
-
2
3
1
4
contact view
pin
1
2
3
4
color code
RED-BLK TR.
RED-WHT TR.
RED
GREEN
25-ft. cable:
2-wire
8...34 vdc
4...20 mA
earth ground
3-wire
14...29 vdc
0...20 mA
common
-
color code
RED
BLACK
WHITE
GREEN
2-wire
3-wire
8...34 vdc 14...29 vdc
4...20 mA
common
earth ground 0...20 mA
tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799
meas-spec.com
PT5MA | 3
Output Signal Selection:
0...20 mA
or
4...20 mA
20...0 mA
or
20...4 mA
signal board
internal dip switches
& signal board
1 2 3 4
switch setting
1 2 3 4
output signal
1 2 3 4
The output signal direction can
be reversed at any time by
simply changing the dip-switch
settings found on the internal
signal board. After the settings
have been changed, adjustment of the Zero and Span
trimpots will be required to
precisely match signal values to
the beginning and end points
of the stroke.
To gain access to the signal board, remove four
Allen-Head Screws and remove end cover bracket.
dip-switch location
Caution! Do Not Remove Spring-Side End Cover
Removing spring-side end cover could cause spring
to become unseated and permanently damaged.
version: 8.0 last updated: March 28, 2014
tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799
meas-spec.com
4 | PT5MA