FGM Data sheet Sensing element/Gauge ■Features Surface mount package ■Ordering Information FGM-6 07P G SR Terminal leads configuration Surface mount package Model Length of the pressure port 3:3mm 6:6mm Measurable pressure range(kPa) -13.79 to 13.79 -34.47 to 34.47 -48.26 to 48.26 -98.07 to 103.4 -98.07 to 206.8 -98.07 to 344.7 -98.07 to 482.6 -98.07 to 827.4 Pressure type Rated Pressure (PSI) G:Gauge Pressure Weight (grams) Weight (grams) 0.3 0.35 Part number 3mm pressure port FGM-302PGSR FGM-305PGSR FGM-307PGSR FGM-315PGSR FGM-330PGSR FGM-350PGSR FGM-370PGSR FGM-3120PGSR 6mm pressure port FGM-602PGSR FGM-605PGSR FGM-607PGSR FGM-615PGSR FGM-630PGSR FGM-650PGSR FGM-670PGSR FGM-6120PGSR RoHS compliance ■Specifications Model 02PG Recommended operating conditions Pressure type Rated pressure Measurable pressure range Temperature range Pressure media Excitation current (Constant) 13.79 -13.79 to 13.79 05PG 07PG 34.47 -34.47 to 34.47 48.26 -48.26 to 48.26 15PG 30PG 50PG Gauge pressure 103.4 206.8 344.7 -98.07 -98.07 -98.07 to 103.4 to 206.8 to 344.7 0 to 50 Non-corrosive gases only (No liquid) 1.5 Absolute maximum rating Maximum load pressure Twice of rated pressure 3.0 -20 to 100 -40 to 120 30 to 80 (Non dew condition) Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C) Output span voltage 60 to 140 (at 0kPa to rated pressure) Offset voltage +/-20 (at 0kPa) Bridge resistance 4000 to 6000 Response time 2 (for the reference) Accuracy TSO* +/-5 TCS* 2.5 Linearity +/-0.5 +/-0.3 Pressure hysteresis +/-0.4 +/-0.2 70PG 120PG 482.6 -98.07 to 482.6 827.4 -98.07 to 827.4 1 kPa kPa deg.C mADC 1.5 times of rating pressure mADC deg.C deg.C %RH Maximum excitation current Operating temperature Storage temperature Operating humidity *TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C) *TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C) Unit mV mV Ω msec. %FS/050deg.C +/-0.5 +/-0.6 +/-0.4 %FS %FS FGM Data sheet Sensing element/Gauge P1= 0 kPa P2= 1/2 x P3 (kPa) P3= reted pressure (kPa) T1= 0 deg.C T2= 25 deg.C T3= 50 deg.C Offset voltage (mV) Voff = V(P1,T) Voff(0) = V(P1,T1) Voff(25) = V(P1,T2) Voff(50) = V(P1,T3) Output voltage at full scale (mV) Vfs = V(P3,T) Vfs(0) = V(P3,T1) Vfs(25) = V(P3,T2) Vfs(50) = V(P3,T3) Output span voltage (mV) SV = Vfs - Voff SV(0) = Vfs(0) - Voff(0) SV(25) = Vfs(25) - Voff(25) SV(50) = Vfs(50) - Voff(50) Temperature sensitivity of offset voltage (%FS) TSO = {LARGER ONE} / SV(25) x 100 LARGER ONE = larger absolute value which of {Voff(0)-Voff(25)} and {Voff(50)-Voff(25)} Temperature coefficient of output span voltage (%FS) TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100 Linearity (%FS) NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100 Pressure hysteresis (%FS) Phys = {Voff’(25) - Voff(25) } / SV(25) x 100 Voff’(25) : Output voltage against P1 after stressing by P3 pressure. 2 FGM Data sheet Sensing element/Gauge ■Outline dimensions■ 2-φ1.1 3 FGM Data sheet Sensing element/Gauge ■Connection diagram■ ■Output characteristics■ <302PG~307PG> <602PG~607PG> <315PG~3120PG> <615PG~6120PG> ↑Output voltage(mV) ↑Output voltage(mV) Output span voltage Offset voltage -Rated pressure Offset voltage -98.07kPa 0kPa 0kPa Rated pressure →Pressure(kPa) Rated pressure →Pressure(kPa) Atomospheric pressure Note ; Output span voltage Atomospheric pressure Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag. If the sensors expose to an atmosphere, the pins will be black by sulfuration. Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using. 4 FGM Data sheet Sensing element/Gauge Reflow Soldering process recommendation profile Package Surface Temperature (Degree C) 230 210 150 Room Temp. Time a a: Rump up rate b: Pre-heating c: Rump up rate d: Heating e: Rump down rate Note ; b c d e 1 or 2 deg.C/sec. 150 to 180 deg.C,within 60 to120sec. 1 to 2 deg.C/sec. max.230 deg.C,max.10sec. 210 deg.C,within 30sec. 1 or 2 deg.C/sec. 1 ) Temperature means Surface temperature of the sensor package. 2 ) Reflow process max. 2 times. 3 ) Do not wash the sensor. 4 ) Do not put the solder and flux on the sensor package. If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected] 5