FUJIKURA FGMC

FGM-3,FGM-6 Data sheet
Sensing element/Gauge
Features
Applications
. Very small surface mountable package, Easy to mount on PCB
. Vacuum pressure measurable
. Industrial instrumentation
. Pressure switch, Pneumatic device
. Non-corrosive liquid measurable(FGMC-3, FGMC-6 available)
. Medical device
. Turbo boost pressure measurement for Automotive system
Part number for ordering
FGM C - 3 07P G S R
Terminal leads direction(See Outline Diagram)
Rated pressure
R:
(PSI)
Model
Length of the pressure port
FGM
Terminal leads configuration
3 : 3mm
S : Surface mount package
Pressure type
6 : 6mm
G : Gauge pressure
Available pressure media
No mark : Non-corrosive gas only
C : Non-corrosive gas and liquid (Contact us about availability)
Pressure type
Gauge pressure
FGM-3
FGM-6
Package configuration
Surface mount package, 3mm pressure port
Surface mount package, 6mm pressure port
Measurable pressure range (kPa)
13.79 13.79
34.47 34.47
48.26 48.26
98.07 103.4
98.07 206.8
98.07 344.7
98.07 482.6
98.07 827.4
FGM-302PGSR
FGM-305PGSR
FGM-307PGSR
FGM-315PGSR
FGM-330PGSR
FGM-350PGSR
FGM-370PGSR
FGM-3120PGSR
Model
Part number for ordering
FGM-602PGSR
FGM-605PGSR
FGM-607PGSR
FGM-615PGSR
FGM-630PGSR
FGM-650PGSR
FGM-670PGSR
FGM-6120PGSR
Specifications
Model/Rated pressure
02PG
05PG
07PG
15PG
30PG
50PG
70PG
Accuracy
Recommended operating conditions
Pressure type
Gauge pressure
13.79
34.47
48.26
103.4
206.8
344.7
482.6
Rated pressure
0.141
0.352
0.492
1.055
2.109
3.516
4.922
13.79
34.47
48.26
98.07
98.07
98.07
98.07
Measurable pressure range
13.79
34.47
48.26
103.4
206.8
344.7
482.6
Pressure media
FGM : Non-corrosive gas only, FGMC : Non-corrosive gas and liquid
Excitation current (Constant)
1.5
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3
Operating temperature
20 100
Storage temperature
40 120
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation current I=1.5mA constant, Ambient temperature Ta=25 )
Full scale span voltage
60 140
Offset voltage
20
Bridge impedance
4000 6000
Mechanical response time
2 (For the reference)
Temperature sensitivity of offset (TSO)
5
Temperature coefficient of sensitivity (TCS)
2.5
Linearity
0.5
0.3
0.5
Pressure hystersis
0.4
0.2
) Please consult us available liquid pressure media when you chose the C models.
1
120PG
Unit
827.4
8.437
98.07
827.4
kPa
kg/cm2
kPa
mADC
1.5times of rated pressure
mADC
RH
mV
mV
0.6
0.4
msec
FS/0 50
FS/0 50
FS
FS
FGM-3,FGM-6 Data sheet
Sensing element/Gauge
Outline dimensions
unit(mm)
FGM-3
2.54 2.54
0.8
Pressure port
2
6
5
3
7
1
4
7
3
Vent hole
0.25
X.
15
0.8
6.5
3.5
0.15
3
Index
MA
10.3
5
Recommended footprint for PCB
4
Labelled faceplate
1.7
1
2.54 2.54
1.4
6
1
2
9.4
Land-pads
3
unit(mm)
unit(mm)
FGM-6
2.54 2.54
0.8
Pressure port
2
6
5
3
7
1
4
7
Vent hole
3
0.5
Projections
5
4
2-R0.5
Recommended footprint for PCB
1.7
1
1
Projections
2
2- 1(Holes for projections)
2
3
Labelled faceplate
Land-pads
6.0
6
2.54 2.54
10.3
1.4
0.8
MA
0.25
X.
15
3.5
9.5
6
Index
6.0
9.4
unit(mm)
FGM-3,FGM-6 Data sheet
Sensing element/Gauge
Connection diagram
unit(mm)
FGM
i
1.5mA
2
Output voltage
R2
Constant
current
source
R1
1
3
6
R3
R4
5
1
VR0
6
Zero balancing trimmer (VR0) is available.
VR0 :200
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
3
E-mail : [email protected]