NetSure 9500, 400V DC Power System – Up to 600kW
Pre-Quote Information Form
Requester’s Contact Information:
Name/Title*
Company*
Email*
Phone*
*These are required fields. Please complete before submitting the form.
A) Select Product Destination:
Rest of World
North America
B) System Grounding Type:
H
RMG (High Resistance Mid-Point Ground)
C) Select IT Rack Integration:
4 2 U, Seismic Zone 4 (P/N 557858)
42 U, Standard (P/N 557861)
D) Select AC Input:
AC Input Voltage:
380 VAC
400 VAC
AC Distribution Type:
Delta
Wye
480 VAC
Power Module/Bay
E) Select Power Module/Bay Quantity (120kW capacity, each):
Main Power Module/Bay (List 1)
0
1
Expansion Power Module/Bay (List 3)
0
1
2
Refer to Items E – I
3
If 0, skip to
Step J.
4
F) Enter Rectifier Quantity (Up to 8 1R40015000e rectifiers per Power Module/Bay):
Number of Rectifiers
Total System Capacity
x 15 kW =
0
kW (600 kW Max.)
G) Select Distribution Configuration for Each Power Module/Bay: (List 21HA or 23HA)
21U Load Dist. Panel* – OR –
Bulk Dist. Panel
Main Power Module/Bay
0
1*
0
1
2
3
Expansion Power Module/Bay 1
0
1*
0
1
2
3
Expansion Power Module/Bay 2
0
1*
0
1
2
3
Expansion Power Module/Bay 3
0
1*
0
1
2
3
Expansion Power Module/Bay 4
0
1*
0
1
2
3
Power Module/Bay
with Bulk Distribution Panels (left)
with Load Distribution Panel (right)
* If Load Distribution Panel is selected, complete breaker configuration selection in Step H.
H) Configure Breakers for each Power Module/Bay with a Load Distribution Panel (LDP)
(Select Up to 16 Breakers Per Panel):
Breaker Qty. per
Module/Bay
Amps
15
Main Power Module/Bay
Expansion Module/Bay 1
Expansion Module/Bay 2
Expansion Module/Bay 3
Expansion Module/Bay 4
20
25
30
40
50
60
70
80
90 100
Total
0
0
0
0
0
Additional Information
n EmersonNetworkPower.com/400VDC
n NetSure™ 9500 Web Page
nSystem Application Guide
Note: Breakers must be derated to 70%.
EN614QRB-NS9500 / 0315
1
NetSure 9500 Pre-Quote Information Form
Power Module/Bay (continued)
I) Select Quantity of Temperature Probes: (Up to 6 for Main Power
Refer to Item J
Module/Bay, Up to 2 for each Expansion Power Module/Bay)
Qty.
12 ft. (3.3 m) long (P/N 558572)
33 ft. (10.3 m) long (P/N 558573)
Distribution Module/Bay
J) Enter Distribution Module/Bay Quantity (List 7):
21U Load Dist.
Panel Quantity
(List 21HA)
Distr. Module/Bay #1
1
2
Distr. Module/Bay #2
1
2
Distr. Module/Bay #3
1
2
Distr. Module/Bay #4
1
2
Distr. Module/Bay #5
1
2
1
2
If 2 Panels Selected,
Configure Input Feed
Separate
Single
Input Feeds1 Input Feed2
Distribution
Module/Bay
Battery Cabinet
L) Select Up to 6 Battery Cabinets (List 90-93):
Qty.
With C&D Batteries (crated pkg.)
Separate input feeds for top and bottom distribution panels.
Panels interconnected for single feed.
With C&D Batteries (standard pkg.)
With Enersys Batteries (standard pkg.)
K) Configure Breakers for each Distribution Module/Bay
With GNB Batteries (standard pkg.)
Select Up to 16 Breakers Per Panel:
Amps
15 20 25 30 40 50 60 70 80 90 100 Total
Breaker Quantity per
Distribution Module/Bay
Bay 1, Panel 1
0
0
0
0
0
0
0
0
0
0
Bay 1, Panel 2
Bay 2, Panel 1
Bay 2, Panel 2
Bay 3, Panel 1
Bay 3, Panel 2
Bay 4, Panel 1
Bay 4, Panel 2
Bay 5, Panel 1
Bay 5, Panel 2
M) If Using Customer Supplied Batteries, Order 1 Alarm Cable
for Each Battery String:
Qty.
Number of Alarm Cables
N) Additional Comments:
Note 1: Breakers must be derated to 80%.
Note 2: T
o configure circuit breakers for additional distribution modules/bays,
enter instructions in Additional Comments section.
Please SAVE this form to your desktop.
Then, email the file to: [email protected]
EmersonNetworkPower.com/EnergySystems (North America)
EmersonNetworkPower.eu/EnergySystems (EMEA)
© Emerson Network Power Energy Systems North America 2015.
Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson® and Consider it Solved are service marks and
trademarks of Emerson Electric Co. EnergyMaster ™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure™ and NetXtend™ are trademarks of Emerson
Network Power Energy Systems North America. Any other product, brand, or company names or logos are the property of the respective owner.
2
While every precaution has been taken to ensure accuracy and
completeness herein, Emerson Electric Co. assumes no responsibility,
and disclaims all liability, for damages resulting from use of this
information or for any errors or omissions. Specifications subject to
change without notice.
EN614QRB-NS9500 / 0315