eSure™ Rectifier R400-15000e Key Features 15kW high-efficiency rectifier designed for 400V DC power applications Optimized depth – reduced footprint allows installation in short-depth racks and cabinets DSP (Digital Signaling Processor) – means fewer components, optimized operation and active load sharing for increased reliability In addition to reducing power consumption and lowering operating cost, eSure™ high-efficiency rectifiers offer superior performance and uncompromised reliability. Description The 15kW high-efficiency eSure™ rectifier (model R400-15000e) is designed to convert standard AC supply voltages into stable 400V DC voltage that is adjustable to application needs. The R400-15000e is a constant power rectifier designed with the latest patented switchmode technology, using DSP (Digital Signaling Processor) functionality for efficient operation. For a higher load capacity, rectifiers can be connected in parallel, and intelligent control can be added with the help of a separate controller. Compliant with global standards – delivers quality, performance and reliability no matter what the application or location demands High efficiency, peak 97% – reduces power consumption for lower operating costs Hot pluggable – facilitates future expansions and easy maintenance Efficiency eSure™ Rectifier Efficiency Curve 98% Wide input voltage range to operate in the most demanding environments 96% 94% eSure™Rectifier 92% 90% Wide temperature operating range to meet the harshest climatic environments 88% 86% 84% 0% 20% 40% 60% 80% 100% Load Load Load 2013.04 1 eSure™ Rectifier R400-15000e Output Current Output Current Limit Set Point Efficiency Control and Monitoring Rectifier Alarm and Signaling Visual Indications Environmental Temperature Range, Operating Temperature Range, Storage Relative Humidity Altitude 260 120 80 60 40 20 0 200 250 300 Alarm and status reported via CAN bus to system controller Green LED: Normal Operation Yellow LED: Alarm Red LED: Failure Mechanics Dimensions (H x W x D) Weight 88 x 218 x 565mm / 3.5 x 8.5 x 22 inches 10 kg / 22 lbs Other Parts Controller Units See separate controller datasheet 400 450 500 550 Output Power vs. Temperature at Uin>340VAC, Vo >336V DC 120 100 80 60 40 20 0 -5 5 15 25 35 45 55 65 Temperature (C°) Output voltage vs. Output current, max. output power 15000 W -40°C to +65°C,-40°F to+149°F (See diagram for de-rating) -40°C to +75°C , -40°F to +167°F 0 to 95% Safety 350 Input Voltage (VAC) See diagram 44.6 A maximum 0 to 44.6 A Peak 97% 530 304 100 290V to 400V DC 15000W @ Vout > 336VDC 2000 m, 6560 ft at full power ETSI EN300 386: 2005, Class B. Other than telecom centers. FCC CFR 47 Part 15, Class B conducted and radiated EN55022, Class B conducted and radiated CISPR22, Class B conducted and radiated Telcordia GR-1089-CORE issue 6 UL 60950-1(US & Canada);EN 60950-1;IEC 60950 EMC Output Power vs. Input Voltage at Tamb <45°C % of max output power DC Output Output Voltage, Adjustment Range Output Power Output Power, Derated for Input Voltage 380V/480V AC 260V to 530V AC 45Hz to 65Hz 30 A 0.99 <5% from 50 to 100% of rated load 44.6 37.5 Output Voltage (V) AC Input Input Voltage, Nominal Input Voltage, Permitted Variation Line Frequency Max Input Current Power Factor THD (Total Harmonic Distortion) Diagrams % of max output power Technical Specifications 400 350 300 250 200 150 100 50 0 0 5 10 15 20 25 30 35 40 45 50 Output Current (A) Ordering Information Product Name Description R400-15000e Rectifier 400V,15kW EmersonNetworkPower.com/EnergySystems (North America) EmersonNetworkPower.eu/EnergySystems (EMEA) © Emerson Network Power Energy Systems North America 2013. Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson® and Consider it Solved are service marks and trademarks of Emerson Electric Co. EnergyMaster™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure™ and NetXtend™ are trademarks of Emerson Network Power Energy Systems North America. Any other product, brand, or company names or logos are the property of the respective owner. 2 While every precaution has been taken to ensure accuracy and completeness herein, Emerson Electric Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. SpecJ»cations subject to change without notice. 2013.04