PCS5038 5962-1223201

REVISIONS
LTR
DESCRIPTION
A
DATE (YR-MO-DA)
APPROVED
15-04-16
Charles F. Saffle
Added the RHA designator "R" to paragraph 1.2. Made correction to
paragraph 4.3.5.1.3, removed the last sentence. Table I: corrected
Output voltage low max limit from "0.4" to "0.5". Table II: corrected
the subgroups for the RHA end point electrical parameters. -sld
REV
SHEET
REV
A
A
SHEET
15
16
REV STATUS
REV
A
A
A
A
A
A
A
A
A
A
A
A
A
A
OF SHEETS
SHEET
1
2
3
4
5
6
7
8
9
10
11
12
13
14
PMIC N/A
PREPARED BY
Steve L. Duncan
STANDARD MICROCIRCUIT
DRAWING
THIS DRAWING IS
AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
CHECKED BY
Greg Cecil
http://www.landandmaritime.dla.mil/
APPROVED BY
Charles F.Saffle
DRAWING APPROVAL DATE
MICROCIRCUIT, OCTAL PRECISION CURRENT
SOURCE, MONOLITHIC SILICON
14-02-06
REVISION LEVEL
A
SIZE
CAGE CODE
A
67268
SHEET
DSCC FORM 2233
APR 97
5962-12232
1 OF
16
5962-E284-15
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A
choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When
available, a choice of radiation hardness assurance levels is reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962
R
Federal
stock class
designator
\
RHA
designator
(see 1.2.1)
12232
01
K
X
C
Device
type
(see 1.2.2)
Device
class
designator
(see 1.2.3)
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
/
\/
Drawing number
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
01
Circuit function
PCS5038
Octal Precision Current Source
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level.
All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K,
and E) or QML Listing (Class G and D). The product assurance levels are as follows:
Device class
Device performance documentation
K
Highest reliability class available. This level is intended for use in space
applications.
H
Standard military quality class level. This level is intended for use in applications
where non-space high reliability devices are required.
G
Reduced testing version of the standard military quality class. This level uses the
Class H screening and In-Process Inspections with a possible limited temperature
range, manufacturer specified incoming flow, and the manufacturer guarantees (but
may not test) periodic and conformance inspections (Group A, B, C and D).
E
Designates devices which are based upon one of the other classes (K, H, or G)
with exception(s) taken to the requirements of that class. These exception(s) must
be specified in the device acquisition document; therefore the acquisition document
should be reviewed to ensure that the exception(s) taken will not adversely affect
system performance.
D
Manufacturer specified quality class. Quality level is defined by the manufacturers
internal, QML certified flow. This product may have a limited temperature range.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
2
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
Descriptive designator
X
See figure 1
Terminals
Package style
40
Ceramic quad flat pack
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
1.3 Absolute maximum ratings. 1/
Supply voltage (VCC) ...................................................................
Thermal resistance, junction-to-case (ƟJC) .................................
Power dissipation ........................................................................
Junction temperature (TJ) ...........................................................
Lead temperature (soldering, 10 seconds) .................................
Storage temperature range .........................................................
+7.0 V dc
5°C/W
420 mW
+150°C
300°C
-65°C to +150°C
1.4 Recommended operating conditions.
Supply voltage (VCC)....................................................................
Case operating temperature range (TC) ......................................
+5.0 V dc
-55°C to +125°C
1.5 Radiation features. 2/ 3/
Maximum Total Ionizing Dose (TID) ..(dose rate = 50 - 300 rad(Si)/s):
In accordance with MIL-STD-883, method 1019, condition A.
100 krad(Si) 4/
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at http://quicksearch.dla.mil or from the Standardization Document Order
Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
_________
1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
2/ See section 4.3.5 for the manufacturer's radiation hardness assurance analysis and testing.
3/ Bipolar device types may degrade from displacement damage from radiation which could affect RHA levels. This device
has not been characterized for displacement damage.
4/ The device will be tested every wafer diffusion lot.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
3
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class. The
manufacturer may eliminate, modify, or optimize the tests and inspections herein, however, the performance requirements as
defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not
affect the form, fit, or function of the device for the applicable device class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Block diagram. The block diagram shall be as specified on figure 3.
3.2.4 Timing diagram(s). The timing diagram(s) shall be as specified on figure 4.
3.2.5 Radiation exposure circuits. The radiation exposure circuits shall be maintained by the manufacturer under document
revision level control and shall be made available to the preparing and acquiring activity upon request.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with
the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample,
for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those
which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be
made available to the preparing activity (DLA Land and Maritime -VA) upon request.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this
drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime -VA shall affirm that the
manufacturer's product meets the performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as
modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form,
fit, or function as described herein.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
4
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions
Group A Device
subgroups type
-55°C ≤ TC ≤ +125°C
VCC +5.0 V dc ± 5%
unless otherwise specified
PCS and comparator groups
1,2,3
01
enabled, ENA_PCS_H ≥ VIH,
ENA_GRP1_H ≥ VIH, IPCS = 2 mA,
ENA_GRP2_H ≥ VIH, R_ISET = 1 kΩ,
CMP(OUT1:8) = VIH
Supply current 1/
ICC
Quiescent current 1/
ICCQ
PCS and comparator groups
disabled, ENA_PCS_H ≤ VIL,
ENA_GRP1_H ≤ VIL,
ENA_GRP2_H ≤ VIL
Short circuit current 2/
ISC
PCS and comparator groups
enabled, R_ISET = 0Ω, TC = +25°C
Precision current source
out 1/
IPCSON
Limits
Min
Unit
Max
30
mA
1,2,3
01
10
mA
1
01
60
mA
ENA_PCS_H ≥ VIH, ENA_GRP1_H
≥ VIH, ENA_GRP2_H ≥ VIH,
100 µA ≤ IPCS ≤ 2 mA, External set
resistor tolerence = ±0.1%
1,2,3
01
IPCS
+0.75%
mA
IPCSOFF
ENA_PCS_H ≤ VIL, ENA_GRP1_H
≥ VIH, ENA_GRP2_H ≥ VIH,
100 µA ≤ IPCS ≤ 2 mA, External set
resistor tolerence = ±0.1%
1,2,3
01
1000
nA
Current source matching
accuracy 1/
IMATCH
Relative to mean of IPCSON(1:8) at
TC = +25°C
1
01
-0.75
+0.75
%
Comparator in voltage 2/
VIN
Input or reference
1,2,3
01
0
3.0
V
Comparator reference in
current
IREF
VREF_GRP1 = VREF_GRP2 = 0 V
1,2,3
01
2.0
µA
Enable input voltage low
ENA_PCS_H (pin 33),
ENA_GRP1_H (pin 32),
ENA_GRP2_H (pin 31)
VIL
1,2,3
01
0.8
V
Enable input voltage high
ENA_PCS_H (pin 33),
ENA_GRP1_H (pin 32),
ENA_GRP2_H (pin 31)
VIH
1,2,3
01
Output voltage low 1/
CMPOUT(1:8),
(pins 1-4 and 12-15)
VOL
ISINK ≤ 2.0 mA
1,2,3
01
Output voltage high 1/
CMPOUT(1:8),
(pins 1-4 and 12-15)
VOH
No load
1,2,3
01
4.4
Internal output pull-up 2/
resistor
RINT
1,2,3
01
8
Input open circuit voltage
VINOC
1,2,3
01
R_ISET pin voltage 1/
VSET
1
01
R_ISET temperature
coefficient
VSET-TC
1,2,3
01
TC = +25°C
IPCS 0.75%
2.0
V
0.5
V
V
12
kΩ
VCC
V
1.990
2.010
V
-0.75
+0.75
%
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
5
TABLE I. Electrical performance characteristics - Continued.
Test
Band gap output voltage 1/
BGR_VREF (pin 26)
Band gap load regulation
BGR_VREF (pin 26) 2/
Symbol
1
01
2,3
∆VBG
∆IBG
tDHL1
Comparator enable delay
3/
tDLH2
IPCS enable delay 3/
tDLH3
tDHL2
tDHL3
2/
3/
Group A Device
subgroups type
VBG
Comparator pulse delay 3/ tDLH1
1/
Conditions
-55°C ≤ TC ≤ +125°C
VCC +5.0 V dc ± 5%
unless otherwise specified
BG IOUT ≤ 2 mA
Limits
Unit
Min
Max
1.990
2.010
1.980
2.020
V
1,2,3
01
5
mV
CL = 30 pF, VREF = 1.0 V dc,
VIN overdrive ≥ 50 mV,
See figure 4
9,10,11
01
300
ns
CL = 30 pF, VREF = 1.0 V dc,
VIN = 1.05 V dc, See figure 4
9,10,11
CL = 30 pF, VREF = 1.0 V dc,
RIN = 1 KΩ, R_ISET = 1 KΩ,
IPCS = 2 mA, See figure 4
9,10,11
1000
01
1500
ns
1000
01
10
µs
750
ns
The active element that makes up this device has been tested to 150 krad(Si)) to assure RHA designator level "R" (100
krad(Si)) of Method 1019, condition A of MIL-STD-883 at +25°C for these parameters.
Not tested. Shall be guaranteed by design, characterization, or correlation to other test parameters.
Includes text fixture node capacitance plus 10 pF scope capacitance.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
6
FIGURE 1. Case outline.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
7
Case outline X - Continued.
Symbol
A
A1
A2
b
c
D/E
D1
e
F
J
L
L1
L2
L3
L4
N
S1
S2
Inches
Min
Max
.120
.111
.005
.011
.0135
.0195
.004
.008
.590
.610
.444
.456
.050 BSC
.200 TYP
.035 TYP
2.490
2.510
2.580
1.700
1.740
2.090
2.110
.750 TYP
40
.030 TYP
.015 TYP
Millimeters
Min
Max
3.05
2.82
.13
.28
.343
.495
.10
.20
14.99
15.49
11.28
11.58
1.27 BSC
5.08 TYP
.89 TYP
63.25
63.75
65.53
43.18
44.20
53.09
53.60
19.05 TYP
40
.76 TYP
.38 TYP
NOTES:
1. Pin 1 is indicated by the ESD marking on top of the package and the extended lead on the bottom of the package.
2. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound
units shall rule.
3. N equals 40, the total number of leads on the package.
4. Pin numbers are for reference only.
FIGURE 1. Case outline - Continued.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
8
Device
type
01
Case
outline
Terminal
number
X
Terminal
symbol
Terminal
number
Terminal
symbol
1
CMPOUT(1)
21
CASE_GND
2
CMPOUT(2)
22
CASE_GND
3
CMPOUT(3)
23
VCC
4
CMPOUT(4)
24
GND
5
VCC
25
R_ISET
6
GND
26
BGR_VREF
7
PCS(8)
27
CASE_GND
8
PCS(7)
28
CASE_GND
9
PCS(6)
29
R_ISET_RTN
10
PCS(5)
30
CASE_GND
11
VREF_GRP2
31
ENA_GRP2_H
12
CMPOUT(5)
32
ENA_GRP1_H
13
CMPOUT(6)
33
ENA_PCS_H
14
CMPOUT(7)
34
GND
15
CMPOUT(8)
35
VCC
16
VCC
36
PCS(4)
17
GND
37
PCS(3)
18
GND
38
PCS(2)
19
CASE_GND
39
PCS(1)
20
CASE_GND
40
VREF_GRP1
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
9
NOTE: Ground pins 19, 20, 21, 22, 27, 28, and 30 are connected to CASE and should be grounded.
FIGURE 3. Block diagram.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
10
FIGURE 4. Timing diagram(s).
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
11
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group A
test table)
Interim electrical parameters
1
Final electrical parameters
1*,2,3,9,10,11
Group A test requirements
1,2,3,9,10,11
Group C end-point electrical
parameters
1,2,3,9,10,11
End-point electrical parameters
for Radiation Hardness Assurance
(RHA) devices
1
* PDA applies to subgroup 1.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a.
b.
Burn-in test, method 1015 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime-VA or the acquiring activity upon request.
Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance
with the intent specified in method 1015 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1015 of MIL-STD-883.
Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
Tests shall be as specified in table II herein.
b.
Subgroups 4, 5, 6, 7, and 8 shall be omitted.
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
12
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
End-point electrical parameters shall be as specified in table II herein.
b.
Steady-state life test, method 1005 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime-VA or the acquiring activity upon request.
Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance
with the intent specified in method 1005 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1005 of MIL-STD-883.
(3)
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5. Radiation hardness assurance (RHA). RHA qualification is required only for those devices with the RHA designator as
specified herein. See table IIIA and table IIIB.
Table IIIA. Radiation Hardness Assurance Method Table.
RHA
method
employed
Total Dose Testing
RHA level "R"
(100 krad)
Element level
Tested at
(150 krad)
See
4.3.5.1.1
Worst Case Analysis Performed
End point electricals after
total dose
Hybrid
Includes
Combines
Combines End-of-life Element level Hybrid device level
device level temperature temperature total dose and
effects
and radiation displacement
effects
effects
Tested at
No
No
No
No
TC = +25°C
TC = +25°C
(150 krad)
See
4.3.5.1.1
Table IIIB. Hybrid level and element level test table.
Radiation Test
Total Dose
Heavy Ion
Low Dose Rate High Dose Rate ELDRS
SET
SEL
(LDR)
(HDR)
(transient) (latch-up)
Bipolar DI
Not
tested
Tested at
(150 krad)
Not
tested
Not
tested
G
Proton
Low
High
Energy Energy
SEE
(upset)
Not
tested
Not
tested
Not
tested
Neutron
Displacement
Damage (DD)
Not
tested
NOTE:
G = Guaranteed by design or process.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
13
4.3.5.1 Radiation Hardness Assurance (RHA) inspection. RHA qualification is required for those devices with the RHA
designator as specified herein. End-point electrical parameters for radiation hardness assurance (RHA) devices shall be
specified in table II. Radiation testing will be in accordance with the qualifying activity (DLA Land and Maritime -VQ) approved
plan and with MIL-PRF-38534, Appendix G.
a.
The hybrid device manufacturer shall establish procedures controlling component radiation testing, and shall establish
radiation test plans used to implement component lot qualification during procurement. Test plans and test reports
shall be filed and controlled in accordance with the manufacturer's configuration management system.
b.
The hybrid device manufacturer shall designate a RHA program manager to oversee component lot qualification, and
to monitor design changes for continued compliance to RHA requirements.
4.3.5.1.1 Hybrid level RHA qualification. Hybrid level and element level testing are the same for this device on this Standard
Microcircuit Drawing (SMD) since the active element is accessible to the device leads for test.
4.3.5.1.2. Total ionizing dose irradiation testing. A minimum of 5 biased devices of the active element used will be tested
every wafer lot. This active element will be tested at HDR in accordance with condition A of method 1019 of MIL-STD-883 to
150 krad(Si) to assure 100 krad(Si) for the device parameters as specified in table I herein.
4.3.5.1.3 Accelerated annealing test. Accelerated annealing tests shall be performed on all devices requiring a RHA level
greater than 5 krad(Si). The post-anneal end-point electrical parameter limits shall be as specified in table I herein and shall be
the pre-irradiation end-point electrical parameter limit at 25°C ±5°C.
4.3.5.2 RHA Lot Acceptance. Each lot of this hybrid device shall be evaluated for acceptance in accordance with MIL-PRF38534 and herein.
4.3.5.2.1 Total Ionizing Dose (TID). See paragraph 4.3.5.1.2 and 4.3.5.1.3 herein.
4.3.5.2.2 Enhanced Element Evaluation. Enhanced Element Evaluation per Table IV herein including 45 devices subjected to
Group C2, 1000 hours life testing, is required only for those devices with the RHA designator as specified herein.
4.3.5.2.3 Radiation Lot Acceptance Testing (RLAT). Every wafer diffusion lot of this IC used in this monolithic hybrid
microcircuit device will be Radiation Lot Acceptance Testing (RLAT) tested at HDR in accordance with condition A (dose rate of
50 - 300 rad(Si)/s) of method 1019 of MIL-STD-883. A minimum of 5 samples under worst case biased conditions will be tested.
0.9000/90% statistics are applied to the device parameters as specified in table I herein.
4.3.5.2.4 RHA Device Package Type. Enhanced Element Evaluation testing per paragraph 4.3.5.2.2 and RLAT per
paragraph 4.3.5.2.3 will be performed on every wafer diffusion lot with the monolithic IC die in the same package, as specified in
1.2.4 herein, used for compliant devices with the RHA designator as specified herein.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
14
Table IV. Enhanced Element Evaluation For Microcircuit Die.
Subgroup
Class
K
2
X
1
3
4
Test
MIL-STD-883
Method
Condition
2010
X
X
X
Element visual
Assembled into package
as specified in 1.2.4
herein.
Element electrical
Internal visual
Temperature cycling
X
Constant acceleration
2001
X
Burn-in
1015
X
X
Interim electrical
Burn-in
1015
X
X
Post burn-in Final
Electrical, Group A
Steady-state life
1005
5
X
X
Final electrical
Wire bond evaluation
2011
6
X
SEM
2018
Quantity
(accept number)
100 percent
100 percent
2017
1010
100 percent
45(0)
45(0) 2/
C
3000g’s, Y1
direction
160 hours
minimum at
+125°C
Reference
Paragraph
1/
C.3.3.2
C.3.3.1
C.5.5
C.3.3.3
C.5.6
C.3.3.4.3
160 hours
minimum at
+125°C
C.5.10
1000 hours
minimum at
+125°C
10(0) wires or
20(1) wires
See method 2018
of MIL-STD-883
C.3.3.4.3
C.3.3.3
C.3.3.5
C.3.3.6
1/ See MIL-PRF-38534.
2/ Die shall be traceable to the wafer and wafer lot. The sample size shall consist of a minimum of 3 die from each wafer
and a minimum of 45 die from each wafer lot.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractorprepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF38534.
6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires
configuration control and the applicable SMD to that system. DLA Land and Maritime will maintain a record of users and this list
will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices
(FSC 5962) should contact DLA Land and Maritime-VA, telephone (614) 692-8108.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
15
6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime-VA, Columbus, Ohio 43218-3990,
or telephone (614) 692-1081.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors, listed in MIL-HDBK103 and QML-38534, have submitted a certificate of compliance (see 3.7 herein) to DLA Land and Maritime-VA and have
agreed to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-12232
A
REVISION LEVEL
A
SHEET
16
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 15-04-16
Approved sources of supply for SMD 5962-12232 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DLA Land and Maritime -VA. This information
bulletin is superseded by the next dated revisions of MIL-HDBK-103 and QML-38534. DLA Land and Maritime
maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/.
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-1223201KXC
5962R1223201KXC
88379
88379
PCS5038-201-1S
PCS5038-901-1S
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the Vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
Vendor CAGE
number
88379
Vendor name
and address
Aeroflex Plainview Incorporated,
(Aeroflex Microelectronic Solutions)
35 South Service Road
Plainview, NY 11803-4193
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.