R139 Reliability Data

RELIABILITY DATA
LT1524 / LT1525 / LT3524 / LT3525
8/21/2006
• OPERATING LIFE TEST
PACKAGE
TYPE
SAMPLE
SIZE
OLDEST
DATE CODE
CERDIP
PLASTIC DIP
NEWEST
DATE CODE
686
8343
412
8352
1,098
• HIGHLY ACCELERATED STRESS TEST AT +131°C/85%RH
PACKAGE
TYPE
SAMPLE
SIZE
OLDEST
DATE CODE
PLASTIC DIP
187
9107
187
• PRESSURE COOKER TEST AT 15 PSIG, +121°C
PACKAGE
TYPE
SAMPLE
SIZE
PLASTIC DIP
SOIC/SOT/MSOP
1,119
139
1,258
• TEMP CYCLE FROM -65°C to +150°C
PACKAGE
TYPE
SAMPLE
SIZE
CERDIP
PLASTIC DIP
SOIC/SOT/MSOP
SAMPLE
SIZE
NEWEST
DATE CODE
8352
9111
9807
9422
OLDEST
DATE CODE
NEWEST
DATE CODE
OLDEST
DATE CODE
1,712.22
1,006.01
2,718.23
K DEVICE
(4)
HOURS
AT +85°C
9324
NEWEST
DATE CODE
482
8406
171
9107
90
9111
743
• THERMAL SHOCK FROM -65°C to +150°C
PACKAGE
TYPE
9404
9813
OLDEST
DATE CODE
CERDIP
PLASTIC DIP
SOIC/SOT/MSOP
K DEVICE
HOURS (1)
AT +125°C
482.44
482.44
NEWEST
DATE CODE
96.35
5.50
101.84
K DEVICE
CYCLES
42.80
162.76
11.16
216.72
K DEVICE
CYCLES
362
8406
9935
134
9107
9236
90
9111
9120
586
(1) Assumes Activation Energy = 1.0 Electron Volts
(2) Failure Rate Equivalent to +55°C, 60% Confidence Level = 0.68 FITS
(3) Mean Time Between Failures in Years = 167,760
(4) Assumes 20X Acceleration from 85°C to +131°C
Note: 1 FIT = 1 Failure in One Billion Hours.
Form: 00-03-6209B. R139
0
0
0
NUMBER
OF
FAILURES
0
0
NUMBER
OF
FAILURES
K DEVICE
HOURS
9935
9937
9120
NUMBER
OF (2)
FAILURES
5.43
31.40
9.00
45.83
1
0
1
NUMBER
OF
FAILURES
0
0
0
0
NUMBER
OF
FAILURES
0
0
0
0
Rev 20