RELIABILITY DATA LM10 8/21/2006 • OPERATING LIFE TEST PACKAGE TYPE SAMPLE SIZE OLDEST DATE CODE CERDIP HERMETIC PLASTIC DIP NEWEST DATE CODE 200 9717 90 8812 349 9341 639 • HIGHLY ACCELERATED STRESS TEST AT +131°C/85%RH PACKAGE TYPE SAMPLE SIZE OLDEST DATE CODE PLASTIC DIP 248 9633 248 • PRESSURE COOKER TEST AT 15 PSIG, +121°C PACKAGE TYPE SAMPLE SIZE PLASTIC DIP 548 548 • TEMP CYCLE FROM -65°C to +150°C PACKAGE TYPE SAMPLE SIZE CERDIP HERMETIC PLASTIC DIP SAMPLE SIZE NEWEST DATE CODE 9221 9823 OLDEST DATE CODE NEWEST DATE CODE OLDEST DATE CODE 107.52 109.09 685.31 901.91 K DEVICE (4) HOURS AT +85°C 9747 NEWEST DATE CODE 20 9718 47 8749 450 9236 517 • THERMAL SHOCK FROM -65°C to +150°C PACKAGE TYPE 9717 9331 9821 OLDEST DATE CODE CERDIP HERMETIC PLASTIC DIP K DEVICE HOURS (1) AT +125°C 206.40 206.40 NEWEST DATE CODE 26.30 26.30 K DEVICE CYCLES 2.00 4.70 45.00 51.70 K DEVICE CYCLES 68 9433 9718 47 8749 9834 199 9239 9447 314 (1) Assumes Activation Energy = 1.0 Electron Volts (2) Failure Rate Equivalent to +55°C, 60% Confidence Level = 2.04 FITS (3) Mean Time Between Failures in Years = 55,920 (4) Assumes 20X Acceleration from 85°C to +131°C Note: 1 FIT = 1 Failure in One Billion Hours. Form: 00-03-6209B. R065 0 0 0 0 NUMBER OF FAILURES 0 0 NUMBER OF FAILURES K DEVICE HOURS 9718 9834 9823 NUMBER OF (2) FAILURES 5.10 0.71 19.90 25.71 0 0 NUMBER OF FAILURES 0 0 0 0 NUMBER OF FAILURES 0 0 0 0 Rev 22