IRF 60EPU06

Bulletin PD-20771 Rev.B 01/04
60EPU06
60APU06
Ultrafast Soft Recovery Diode
Features
• Ultrafast Recovery
• 175°C Operating Junction Temperature
trr = 34ns (typ)
IF(AV) = 60Amp
VR = 600V
Benefits
• Reduced RFI and EMI
• Higher Frequency Operation
• Reduced Snubbing
• Reduced Parts Count
Description/ Applications
These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems.
The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited
for HF welding, power converters and other applications where switching losses are not significant portion of the total
losses.
Absolute Maximum Ratings
Max
Units
VR
Parameters
Cathode to Anode Voltage
600
V
IF(AV)
Continuous Forward Current, TC = 116°C
60
A
IFSM
Single Pulse Forward Current, TC = 25°C
600
IFRM 
Maximum Repetitive Forward Current
120
TJ, TSTG
Operating Junction and Storage Temperatures
- 55 to 175
°C
 Square Wave, 20kHz
Case Styles
60EPU06
60APU06
CATHODE
TO BASE
CATHODE
2
1
CATHODE
CATHODE
TO
BASE
CATHODE
2
3
ANODE
TO-247AC (Modified)
1
ANODE
3
ANODE
TO-247AC
1
60EPU06/ 60APU06
Bulletin PD-20771 Rev.B 01/04
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
Min Typ Max Units Test Conditions
VBR, Vr
Breakdown Voltage,
Blocking Voltage
600
VF
Forward Voltage
IR
Reverse Leakage Current
Junction Capacitance
CT
-
-
V
IR = 100µA
-
1.35 1.68
V
IF = 60A
-
1.20 1.42
V
IF = 60A, TJ = 125°C
-
1.11 1.30
V
IF = 60A, TJ = 175°C
-
-
50
µA
VR = VR Rated
-
-
500
µA
TJ = 150°C, VR = VR Rated
-
39
-
pF
VR = 600V
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr
Min Typ Max Units Test Conditions
Reverse Recovery Time
IRRM
Peak Recovery Current
Reverse Recovery Charge
Qrr
-
34
45
-
81
-
ns
TJ = 25°C
-
164
-
TJ = 125°C
-
7.4
-
-
17.0
-
-
300
-
-
1394
-
A
IF = 1A, diF/dt = 200A/µs, VR = 30V
IF = 60A
VR = 200V
diF /dt = 200A/µs
TJ = 25°C
TJ = 125°C
nC
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Parameters
Typ
Max
Units
0.63
K/W
Thermal Resistance, Junction to Case
RthCS ‚
Thermal Resistance, Case to Heatsink
0.2
Wt
Weight
5.5
g
0.2
(oz)
T
‚
2
Min
RthJC
Mounting Torque
Mounting Surface, Flat, Smooth and Greased
1.2
2.4
N*m
10
20
lbf.in
60EPU06/ 60APU06
Bulletin PD-20771 Rev.B 01/04
1000
1000
Reverse Current - I R (µA)
100
125˚C
10
1
0.1
25˚C
0.01
0.001
0
T = 175˚C
100
200
300
400
500
600
Reverse Voltage - VR (V)
J
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
T = 125˚C
J
T = 25˚C
1000
Junction Capacitance - C T (pF)
J
10
Tj = 25°C
100
10
1
0
0.5
1
1.5
2
Forward Voltage Drop - VF (V)
2.5
0
3
100
200
300
400
500
600
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Fig. 1 - Typical Forward Voltage Drop Characteristics
1
Thermal Impedance Zth JC (°C/W)
Instantaneous Forward Current - I F (A)
Tj = 175˚C
100
0.7
0.5
0.3
0.1
0.1
R1
R1
TJ
τJ
τ1
0.05
1E-04
R3
R3
TC
τ1
Ci= τi/Ri
Ci= i/Ri
0.01
1E-05
R2
R2
τ2
τ2
τ3
τ3
Ri (°C/W)
0.06226
0.32503
0.24271
τi (sec)
0.00049
0.01294
0.24310
Notes:
1. Duty Factor D = ton/Period
2. Peak Tj = P dm x Zthjc + tc
1E-03
1E-02
1E-01
1E+00
ton , Rectangular Pulse Duration (sec)
1E+01
1E+02
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
3
60EPU06/ 60APU06
Bulletin PD-20771 Rev.B 01/04
140
Average Power Loss ( Watts )
Allowable Case Temperature (°C)
180
150
DC
120
90
Square Wave (D=0.50)
80% Rated Vr applied
60
30
RMS Limit
120
100
80
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
DC
60
40
20
see note (3)
0
0
0
20
40
60
80
0
100
20
40
60
80
100
Average Forward Current - IF(AV)(A)
Average Forward Current I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
300
3000
Tj = 125°C
Tj = 25°C
Tj = 125°C
Tj = 25°C
2500
250
200
If = 30A
If = 60A
1500
trr (ns)
Qrr (nC)
2000
If = 30A
If = 60A
150
1000
100
500
50
0
10
4
100
1000
10
100
1000
dIf/dt (A/µs)
dIf/dt (A/µs)
Fig. 7 - Typical Stored Charge vs. dif/dt
Fig. 8 - Typical Reverse Recovery Time vs. dif/dt
60EPU06/ 60APU06
Bulletin PD-20771 Rev.B 01/04
Reverse Recovery Circuit
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
dif/dt
ADJUST
di
F
D
IRFP250
G
/dt
S
Fig. 7 - Reverse Recovery Parameter Test Circuit
(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR
3
trr
IF
tb
ta
0
Q rr
2
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.75 I RRM
1
di fF/dt
/dt
di
1. diF/dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by t rr
and IRRM
t rr x I RRM
Q rr =
2
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
Fig. 8 - Reverse Recovery Waveform and Definitions
5
60EPU06/ 60APU06
Bulletin PD-20771 Rev.B 01/04
Outline Table
3.65 (0.144)
15.90 (0.626)
3.55 (0.139)
DIA.
4.70 (0.185)
15.30 (0.602)
60EPU06
2 pins
5.30 (0.209)
2.5 (0.098)
1.5 (0.059)
5.70 (0.225)
5.30 (0.208)
CATHODE
TO
BASE
CATHODE
2
20.30 (0.800)
19.70 (0.775)
5.50 (0.217)
1
3
4.50 (0.177)
(2 PLCS.)
1
14.80 (0.583)
4.30 (0.170)
14.20 (0.559)
3
CATHODE
CATHODE
ANODE
ANODE
3.70 (0.145)
2.20 (0.087)
MAX.
1.40 (0.056)
2.40 (0.095)
MAX.
1.00 (0.039)
0.80 (0.032)
0.40 (0.213)
10.94 (0.430)
10.86 (0.427)
Conforms to JEDEC Outline TO-247AC (Modified)
Dimensions in millimeters and (inches)
Outline Table
15.90 (0.626)
15.30 (0.602)
3.65 (0.144)
3.55 (0.139)
DIA.
60APU06
3 pins
5.30 (0.209)
4.70 (0.185)
2.5 (0.098)
1.5 (0.059)
5.70 (0.225)
5.30 (0.208)
20.30 (0.800)
19.70 (0.775)
1
2
3
CATHODE
TO BASE
CATHODE
2
5.50 (0.217)
4.50 (0.177)
(2 PLCS.)
1
14.80 (0.583)
14.20 (0.559)
1.40 (0.056)
1.00 (0.039)
5.47 (0.216)
5.43 (0.213)
ANODE
ANODE
4.30 (0.170)
3.70 (0.145)
2.20 (0.087)
MAX.
3.20 (0.126)
MAX.
2.40 (0.095)
MAX.
0.80 (0.032)
0.40 (0.213)
Conforms to JEDEC Outline TO-247AC
Dimensions in millimeters and (inches)
6
3
ANODE
ANODE
60EPU06/ 60APU06
Bulletin PD-20771 Rev.B 01/04
Ordering Information Table
Device Code
60
E
P
U
06
1
2
3
4
5
1
-
Current Rating
2
-
Single Diode
(60 = 60A)
3
-
TO-247AC (Modified)
4
-
Ultrafast Recovery
5
-
Voltage Rating
E = 2 pins
A = 3 pins
(06 = 600V)
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 08/03
7