Bulletin PD-20771 Rev.B 01/04 60EPU06 60APU06 Ultrafast Soft Recovery Diode Features Ultrafast Recovery 175°C Operating Junction Temperature trr = 34ns (typ) IF(AV) = 60Amp VR = 600V Benefits Reduced RFI and EMI Higher Frequency Operation Reduced Snubbing Reduced Parts Count Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are not significant portion of the total losses. Absolute Maximum Ratings Max Units VR Parameters Cathode to Anode Voltage 600 V IF(AV) Continuous Forward Current, TC = 116°C 60 A IFSM Single Pulse Forward Current, TC = 25°C 600 IFRM Maximum Repetitive Forward Current 120 TJ, TSTG Operating Junction and Storage Temperatures - 55 to 175 °C Square Wave, 20kHz Case Styles 60EPU06 60APU06 CATHODE TO BASE CATHODE 2 1 CATHODE CATHODE TO BASE CATHODE 2 3 ANODE TO-247AC (Modified) 1 ANODE 3 ANODE TO-247AC 1 60EPU06/ 60APU06 Bulletin PD-20771 Rev.B 01/04 Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters Min Typ Max Units Test Conditions VBR, Vr Breakdown Voltage, Blocking Voltage 600 VF Forward Voltage IR Reverse Leakage Current Junction Capacitance CT - - V IR = 100µA - 1.35 1.68 V IF = 60A - 1.20 1.42 V IF = 60A, TJ = 125°C - 1.11 1.30 V IF = 60A, TJ = 175°C - - 50 µA VR = VR Rated - - 500 µA TJ = 150°C, VR = VR Rated - 39 - pF VR = 600V Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) Parameters trr Min Typ Max Units Test Conditions Reverse Recovery Time IRRM Peak Recovery Current Reverse Recovery Charge Qrr - 34 45 - 81 - ns TJ = 25°C - 164 - TJ = 125°C - 7.4 - - 17.0 - - 300 - - 1394 - A IF = 1A, diF/dt = 200A/µs, VR = 30V IF = 60A VR = 200V diF /dt = 200A/µs TJ = 25°C TJ = 125°C nC TJ = 25°C TJ = 125°C Thermal - Mechanical Characteristics Parameters Typ Max Units 0.63 K/W Thermal Resistance, Junction to Case RthCS Thermal Resistance, Case to Heatsink 0.2 Wt Weight 5.5 g 0.2 (oz) T 2 Min RthJC Mounting Torque Mounting Surface, Flat, Smooth and Greased 1.2 2.4 N*m 10 20 lbf.in 60EPU06/ 60APU06 Bulletin PD-20771 Rev.B 01/04 1000 1000 Reverse Current - I R (µA) 100 125˚C 10 1 0.1 25˚C 0.01 0.001 0 T = 175˚C 100 200 300 400 500 600 Reverse Voltage - VR (V) J Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage T = 125˚C J T = 25˚C 1000 Junction Capacitance - C T (pF) J 10 Tj = 25°C 100 10 1 0 0.5 1 1.5 2 Forward Voltage Drop - VF (V) 2.5 0 3 100 200 300 400 500 600 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Fig. 1 - Typical Forward Voltage Drop Characteristics 1 Thermal Impedance Zth JC (°C/W) Instantaneous Forward Current - I F (A) Tj = 175˚C 100 0.7 0.5 0.3 0.1 0.1 R1 R1 TJ τJ τ1 0.05 1E-04 R3 R3 TC τ1 Ci= τi/Ri Ci= i/Ri 0.01 1E-05 R2 R2 τ2 τ2 τ3 τ3 Ri (°C/W) 0.06226 0.32503 0.24271 τi (sec) 0.00049 0.01294 0.24310 Notes: 1. Duty Factor D = ton/Period 2. Peak Tj = P dm x Zthjc + tc 1E-03 1E-02 1E-01 1E+00 ton , Rectangular Pulse Duration (sec) 1E+01 1E+02 Fig. 4 - Max. Thermal Impedance Z thJC Characteristics 3 60EPU06/ 60APU06 Bulletin PD-20771 Rev.B 01/04 140 Average Power Loss ( Watts ) Allowable Case Temperature (°C) 180 150 DC 120 90 Square Wave (D=0.50) 80% Rated Vr applied 60 30 RMS Limit 120 100 80 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 DC 60 40 20 see note (3) 0 0 0 20 40 60 80 0 100 20 40 60 80 100 Average Forward Current - IF(AV)(A) Average Forward Current I F(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics 300 3000 Tj = 125°C Tj = 25°C Tj = 125°C Tj = 25°C 2500 250 200 If = 30A If = 60A 1500 trr (ns) Qrr (nC) 2000 If = 30A If = 60A 150 1000 100 500 50 0 10 4 100 1000 10 100 1000 dIf/dt (A/µs) dIf/dt (A/µs) Fig. 7 - Typical Stored Charge vs. dif/dt Fig. 8 - Typical Reverse Recovery Time vs. dif/dt 60EPU06/ 60APU06 Bulletin PD-20771 Rev.B 01/04 Reverse Recovery Circuit VR = 200V 0.01 Ω L = 70µH D.U.T. dif/dt ADJUST di F D IRFP250 G /dt S Fig. 7 - Reverse Recovery Parameter Test Circuit (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR 3 trr IF tb ta 0 Q rr 2 I RRM 4 0.5 I RRM di(rec)M/dt 5 0.75 I RRM 1 di fF/dt /dt di 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr Fig. 8 - Reverse Recovery Waveform and Definitions 5 60EPU06/ 60APU06 Bulletin PD-20771 Rev.B 01/04 Outline Table 3.65 (0.144) 15.90 (0.626) 3.55 (0.139) DIA. 4.70 (0.185) 15.30 (0.602) 60EPU06 2 pins 5.30 (0.209) 2.5 (0.098) 1.5 (0.059) 5.70 (0.225) 5.30 (0.208) CATHODE TO BASE CATHODE 2 20.30 (0.800) 19.70 (0.775) 5.50 (0.217) 1 3 4.50 (0.177) (2 PLCS.) 1 14.80 (0.583) 4.30 (0.170) 14.20 (0.559) 3 CATHODE CATHODE ANODE ANODE 3.70 (0.145) 2.20 (0.087) MAX. 1.40 (0.056) 2.40 (0.095) MAX. 1.00 (0.039) 0.80 (0.032) 0.40 (0.213) 10.94 (0.430) 10.86 (0.427) Conforms to JEDEC Outline TO-247AC (Modified) Dimensions in millimeters and (inches) Outline Table 15.90 (0.626) 15.30 (0.602) 3.65 (0.144) 3.55 (0.139) DIA. 60APU06 3 pins 5.30 (0.209) 4.70 (0.185) 2.5 (0.098) 1.5 (0.059) 5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) 1 2 3 CATHODE TO BASE CATHODE 2 5.50 (0.217) 4.50 (0.177) (2 PLCS.) 1 14.80 (0.583) 14.20 (0.559) 1.40 (0.056) 1.00 (0.039) 5.47 (0.216) 5.43 (0.213) ANODE ANODE 4.30 (0.170) 3.70 (0.145) 2.20 (0.087) MAX. 3.20 (0.126) MAX. 2.40 (0.095) MAX. 0.80 (0.032) 0.40 (0.213) Conforms to JEDEC Outline TO-247AC Dimensions in millimeters and (inches) 6 3 ANODE ANODE 60EPU06/ 60APU06 Bulletin PD-20771 Rev.B 01/04 Ordering Information Table Device Code 60 E P U 06 1 2 3 4 5 1 - Current Rating 2 - Single Diode (60 = 60A) 3 - TO-247AC (Modified) 4 - Ultrafast Recovery 5 - Voltage Rating E = 2 pins A = 3 pins (06 = 600V) Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 08/03 7