IRF IRUD360CW40

Bulletin PD-20013 Rev.B 10/03
IRUD360CW40
FRED
Ultrafast, Soft Recovery Diode
Features
• Ultrafast Recovery
• 150°C Operating Junction Temperature
LUG
TERMINAL
ANODE 1
LUG
TERMINAL
ANODE 2
VR = 400V
Benefits
•
•
•
•
VF(typ.) = 1.23V
Reduced RFI and EMI
Higher Frequency Operation
Reduced Snubbing
Reduced Parts Count
BASE COMMON CATHODE
IF(AV) = 350A
Description/ Applications
These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The
softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for
HF welding, power converters and other applications where switching losses are not a significant portion of the total
losses.
Absolute Maximum Ratings
Parameters (*)
Max
Units
VR
Cathode-to-Anode Voltage
400
V
IF(AV) @ TC = 25°C
Continuous Forward Current
350
A
IF(AV) @ TC = 110°C
Continuous Forward Current
190
IFSM
Single Pulse Forward Current
1200
PD @ TC = 25°C
Maximum Power Dissipation
570
PD @ TC = 110°C
Maximum Power Dissipation
180
W
Case Styles
IRUD360CW40
TO-244
(*) Per Leg unless otherwise specified
1
IRUD360CW40
Bulletin PD-20013 Rev.B 10/03
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameters
Min Typ Max Units Test Conditions
VBR
Breakdown Voltage,
400
VFM
Forward Voltage
-
-
V
IR = 100µA
-
1.09 1.27
IF = 180A
-
1.23 1.50
IF = 360A
-
0.88 0.96
IF = 180A @ TJ = 150°C
-
1.04 1.18
IF = 360A @ TJ = 150°C
IRM
Reverse Leakage Current
-
LS
Series Inductance
-
-
-
65
0.26 1.28
5
-
µA
VR = VR Rated
mA
TJ = 150°C, VR = VR Rated
nH
from top of terminal hole to mounting plane
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr
IRRM
Qrr
Min Typ Max Units Test Conditions
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
-
42
69
ns
-
74
-
If = 180A, dif/dt = 200A/µs, Vr = 200V
-
171
-
If = 180A, dif/dt =200A/µs, Vr =200V @ TJ = 125°C
-
5.1
-
-
6.6
-
If = 180A, dif/dt = 200A/µs, Vr = 200V
-
15.2
-
If = 180A, dif/dt =200A/µs, Vr =200V @ TJ = 125°C
-
126
-
-
243
-
If = 180A, dif/dt = 200A/µs, Vr = 200V
-
1295
-
If = 180A, dif/dt =200A/µs, Vr =200V @ TJ = 125°C
A
nC
If = 1.0A, dif/dt = 200A/µs, Vr = 30V
If = 1.0A, dif/dt = 200A/µs, Vr = 30V
If = 1.0A, dif/dt = 200A/µs, Vr = 30V
Thermal - Mechanical Characteristics
Parameters
Min
Typ
Max
Units
TJ
Max. Junction Temperature Range
- 40
-
150
°C
TStg
Max. Storage Temperature Range
- 40
-
150
RthJC
Thermal Resistance, Junction to Case
Per Leg
-
-
0.22
Thermal Resistance, Junction to Case
Per Module
-
-
0.11
-
0.10
-
RthCS
Thermal Resistance, Case to Heatsink
°C/W
flat greased surface
Wt
Weight
-
68 (2.4)
-
g (oz)
T
Mounting Torque
30 (3.4)
-
40 (4.6)
lbf.in
Mounting Torque Center Hole
12 (1.4)
-
18 (2.1)
(N.m)
Terminal Torque
30 (3.4)
-
40 (4.6)
Vertical Pull
-
-
80
2 inch. Lever Pull
-
-
35
2
lbf.in
IRUD360CW40
Bulletin PD-20013 Rev.B 10/03
Reverse Current - IR (µA)
1000
100
10
1
25˚C
0.1
0
100
200
300
Reverse Voltage - VR (V)
100
400
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage (per Leg)
150
Average Power Loss (W)
Instantaneous Forward Current - IF (A)
1000
Tj = 150˚C
10
Tj = 150˚C
Tj = 25˚C
IRUD360CW40
RthJC = 0.24 K/W
140
130
DC
120
D = 0.5
110
100
1
0
0.5
1
1.5
2
0
50
100
150
200
Forward Voltage Drop - VFM (V)
Current Rating - IDC (A)
Fig. 1 - Typical Forward Voltage Drop
vs. Instantaneous Forward Current (per Leg)
Fig. 3 - Max. Current Rating Capability
(per Module)
3
IRUD360CW40
Bulletin PD-20013 Rev.B 10/03
200
240
RMS Limit
Forward Power Loss (W)
tRR (ns)
220
360A
180A
90A
200
180
160
150
DC
100
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
50
0
140
100
200
300
400
0
500
50
150
Forward Current (A)
Fig. 4 - Typical Reverse Recovery vs. dif /dt
Tj = 125°C (per Leg)
Fig. 5 - Forward Power Loss
Characteristics
Reverse Recovery Circuit
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
di F /dt
dif/dt
ADJUST
D
G
IRFP250
S
Fig. 6- Reverse Recovery Parameter Test Circuit
4
100
dif/dt (A/us)
200
IRUD360CW40
Bulletin PD-20013 Rev.B 10/03
3
trr
IF
tb
ta
0
Q rr
2
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.75 I RRM
1
di fF/dt
/dt
di
1. diF/dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by t rr
and IRRM
t rr x I RRM
Q rr =
2
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
Fig. 7 - Reverse Recovery Waveform and Definitions
5
IRUD360CW40
Bulletin PD-20013 Rev.B 10/03
Outline Table
Conforms to JEDEC Outline TO-244
Dimensions in millimeters and (inches)
Ordering Information Table
Device Code
IR
UD
360
C
W
40
1
2
3
4
5
6
1
-
International Rectifier
2
-
Type of Device Indicator:
UD = HEXFRED Gen.2
3
-
Current Rating indicator x1 :
360 = 360A
4
-
Circuit Configuration Indicator:
C = Common Cathode
5
-
Type of Device Indicator:
W = TO-244 Wire Bondable Not Isolated
6
-
Voltage Rating indicator x10 :
40 = 400V
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 10/02