PowerSure Panel LPM/LPL; Sales Brochure; 50/60Hz (R01/10) (SL-22034)

Surge Protection
For Business-Critical Continuity™
PowerSureTM LPM/LPL Series
Surge Protection Solutions For Distribution Panels
Electric power line disturbances such as
high voltage transients can disrupt or
damage sensitive electronic equipment —
causing a major loss in productivity and
money. Liebert understands this problem
and offers the PowerSureTM Low and
Medium Exposure surge protective
devices — the reliable way to keep these
power problems from getting into your
facility in the first place.
PowerSureTM Low Exposure —
Designed for use on branch panels
or equipment in low exposure
locations. Available up to 100kA/
phase surge current capacity.
LED status indication and Form C
contacts for remote indication are
standard.
PowerSureTM Medium Exposure
Offers protection from transients on
distribution panels or any medium
exposure location. Available in
100kA/phase and 160kA/phase,
all mode and two mode protection,
small footprints, NEMA 12 enclosure,
silver link fusing with thermal
protection, all voltage and phase
configurations, 5-year warranty.
PowerSure TM LPM/LPL Series Technical Specifications
Low Exposure (LPL)
Medium Exposure (LPM)
Connection Type
Parallel
Parallel
Operating Voltage Range
±15%
±15%
Surge Current Capacity
25kA, 50kA or 100kA
100kA or 160kA
Fault Current Rating (AIC)
14kAIC
65kAIC
Location Type
Type 2
Type 2
Nominal Discharge Current (In)
3kA
10kA
Dimensions
4.72”x4.72”x2.36”
(160 kA units) 8”x6”x4”
(100 kA units) 6”x4”x3”
Operating Frequency Range
47-63 Hz
47-63 Hz
Capacity
Continuous
Continuous
EMI/RFI Attenuation
40 dB typical
40 dB typical
<0.5 nanoseconds
Response Time
<0.5nanoseconds
Dry Contact Rating
125 VAC, 8.0A, 1.0pf
125 VAC, 8.0A, 1.0pf
Operating Temperature
-40°C to +50°C
-40°C to +50°C
Operating Humidity
0% to 95%
0% to 95%
Status Indication
LEDs, Dry Contacts
LEDs, Dry Contacts
Certifications
ANSI/UL 1449 Third Edition,
cUL, (CE-optional)
ANSI/UL 1449 Third Edition, cUL Listed
Warranty
5-Years
5-Years
Emerson Network Power
Liebert Corporation
World Headquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
United States Of America
800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Emerson Network Power
European Headquarters
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
29/F, The Orient Square Building
F. Ortigas Jr. Road, Ortigas Center
Pasig City 1605
Philippines
+63 2 687 6615
+63 2 730 9572 FAX
liebert.com
Technical Support
ANSI/UL 1449 Third Edition - Voltage Protection Ratings (VPRs)
LPL (all-mode models)
LPM 100-2 / LPM160
120 Volt Systems
600V (L-N), 700V (L-G),
700V (N-G),1000V (L-L)
600V/600V (L-N), 1000V/600V (L-G),
600V/600V (N-G), 1200V/900V (L-L)
208 through 277 Volt Systems
1200V (L-N), 1200V (L-G),
1200V (N-G), 2000V (L-L)
1000V/1000V (L-N), 1800V/1000V (L-G),
1000V/900V (N-G), 2000V/1800V (L-L)
480 Volt Systems
2000V (L-G), 2500V (L-L)
--/1800V (L-G), 2000V/1800V (L-L)
800 288 6169 Toll-Free
607 721 8840 Phone
607 722 8713 Fax
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2010 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
Ordering Information
All names referred to are trademarks or registered trademarks
of their respective owners.
Building a Low and Medium Exposure Model Number:
Examples
(use Model ID column when
L P L 1 2 3
(Low Exposure Unit)
determining 1, 2, 3 portion
of Model Number)
L P M 1 2 3 (Medium Exposure Unit)
® Liebert is a registered trademark of the Liebert Corporation.
SL-22034 (R01/10)
{
1
Nominal Voltage Requirements
2
Model ID
L-N
L-L
L-G
120
N/A
120
120
120
208
120
120
120
240
240
120
N/A
208
208
208
230
400
230
230
N/A
240
240
240
277
480
277
277
N/A
400
400
400
N/A
480
480
480
System Configuration
3
Surge Current Capacity
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
Model ID
(Low Exposure)
Model ID
Single (2 Wire + Gnd)
N or L
Split (3 Wire + Gnd)
S
Wye (4 Wire + Gnd)
Y
Delta Hi-Leg (4 Wire + Gnd)
H
Delta (3 Wire + Gnd)
D
Printed in USA
100 kA/Phase
100
(L-N: 50 kA + L-G: 50 kA; N-G: 50 kA)
50 kA/Phase
50
(L-N: 25 kA + L-G: 25 kA; N-G: 25 kA)
25 kA/Phase
(L-N: 25 kA; N-G: 25 kA)
25-2
(Medium Exposure)
160 kA/Phase
160
(L-N: 80 kA + L-G: 80 kA; N-G: 80 kA)
100 kA/Phase
(L-N: 100 kA; N-G: 100 kA)
100-2
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.com
Business-Critical Continuity™, Emerson Network
Power and the Emerson Network Power logo
are trademarks and service marks of Emerson
Electric Co. ©2010 Emerson Electric Co.