Applicatie flyer power supplies

An Everlasting Supply
Power supplies to suit all your applications
Would you accept a power failure in your application?
Our power supply solutions are never-ending!
Machine manufactoring
Ship building
PRO-M
for applications in non-hazardous
areas
Uninterruptable Power Supplies
for applications with highest
reliability
DC/DC Converter
for applications with galvanic
isolation requirements
•• Process (e.g. Water treatment)
•• Machinery (e.g. Conveying systems)
•• Energy (e.g. Renewable energy)
•• Transportation (e.g. Ship building)
•• Process (e.g. Water treatment)
•• Machinery (e.g. Conveying systems)
•• Energy (e.g. Renewable energy)
•• Transportation (e.g. Ship building)
•• Process (e.g. Water treatment)
•• Transportation (e.g. Ship building)
Wind energy
Process industry
Electronic fuse protection
solution for selective load
protection
INSTAPOWER
for applications wherever space and
efficiency is the overall requirement
PRO-H
for applications in hazardous
areas
•• Process (e.g. Water treatment)
•• Building
•• Very small control cabinets for
­machinery
•• Terminal boxes
•• Process (Oil & Gas, chemical)
•• Energy
Application specific requirements
Weidmüller – power supply solutions for all applications
+
Load
–
+
+
24 V DC
Load
24 V DC
+–
–
–
24 V DC
battery modul
–
+
L
N
PE
Alarm Status
Charging Status
Buffering Status
Increasing the output power
Galvanic isolation and stabilisation
Uninterruptible power supply
Individually adapting the output power
by directly connecting power supply
units in parallel.
DC/DC converters galvanically isolate
the input from the output voltage and
prepare them:
•• INSTAPOWER power supply units:
up to 3 devices can be connected in
parallel.
•• PRO-M power supply units: up to 5
devices can be connected in parallel.
•• Indication of the failure of individual
devices can be achieved using
optional diode modules.
•• to compensate for voltage losses
which occur due to the higher cable
resistance.
•• to avoid ground loops which can
­occur in plants which are spread
over a large area.
•• A potential-free alarm relay and a
transistor output give you full status
monitoring.
•• Special versions, supplied as protection class III devices, mean that you
can use them in floating earth
­systems such as might be found
when operating back-up batteries.
Mains interruptions and brown-outs are
a frequent cause of system failures.
Battery-supported or capacitor based
uninterruptible power supply units
(UPS) units cover these types of mains
network faults and thereby increase
system availability.
TIP
To ensure the most even distribution of the load within the parallel
connected power supply units,
the voltage difference must not
be more than ±50 mV. This
balance is achieved when the
plus wire is connected. Symme­
trical wiring also helps to distri­
bute the current uniformly.
Antenna
Solar Cell
Antenna
24VDC
I/O Devices
and Sensors
I/O 24VDC
24VDC
Radio
Transmitter
24V (powered)
24VDC
SCADA System
or Other Type
of Control System
•• Different status relays permit status
monitoring.
•• The UPS control unit monitors the
input voltage and, in the event of a
fault, switches immediately to
battery operation.
•• When the power is restored, the
input voltage is again switched over
to the load and the battery is
recharged.
•• An integrated deep-discharge
protection system and an optimised
charge curve ensure that the battery
has a long service life.
+
Load
+
–
Load
–
Load 1
+
40 A
A
L1
L2
L3
PE
Status Relay
24 V OK
L1
L2
L3
PE
40 A
Load 2
Load 3
–
Alarm
40 A
A
B
Status Relay
24 V OK
Load 4
B
Reset
L N PE
Power reserve for peak currents
Redundant power supply units
Selective load protection
For selective triggering of circuit
breakers or for short-term additional
power reserves, a capacitor module
can be integrated into the 24 V circuit.
The availability of the power supply
units is increased by the use of redundant circuits. Here, each individual
power supply unit can cope with the
total load required in the event of a
failure by itself.
The breakdown of the whole secondary
load into individual load circuits which
have quick-operating safety elements in
case of a fault is known as selective
load protection. Electronic fuses are
ideal to meet the special requirements
found in selective load protection.
•• The integrated alarm relay monitors
the input voltage, thereby monitoring
the status of the 24 V DC power
supply.
•• Sufficient power for the pulse
triggering of circuit breakers (MCBs)
•• To further increase the power
reserves, multiple capacitor modules
can be connected in parallel.
•• Separate voltage monitoring of the
input channels (alarm relay)
•• Full status monitoring including
voltage monitoring of both inputs
thanks to the integrated Alarm relay.
•• Diode modules give you 100
percent redundancy – this is also
known as “true redundancy”.
TIP
TIP
The capacitor module can be
used independently of the output
power from the power supply
modules. When triggering circuit
breakers, the line impedance
must be observed (see main
catalogue, 4.3).
An example of redundant power
supply units
for an output current of 20A:
2 x PRO-M, 20A + 1x CP M DM20
for 40A output load:
2 x PRO-M, 40A + 1x CP M DM40
•• The tripping characteristic curve of
the electronic fuse is, on the one
hand, fast enough to switch off the
faulty circuit quickly; and on the
other, tolerant enough to deal with a
motor start-up or capacitive loads.
•• A switch to turn the output on or off
means that it is simpler to diagnose
errors and to commission.
•• The fuse triggering is signalled via a
potential-free alarm relay
•• A reset input allows the fuse to be
switched on again remotely.
3 ms
+
–
24 V
PRO-M
50 % of Load
130
120 Additional
Power
110 Reserve
up
to 45°C
100
Pout [% PN]
50 % of Load
24 V
PRO-M
24 V
M
Temperature derating Temperature derating
130
M
90
80
Pout [% PN]
24 V
100 % Load
70
60
t
L
N
PE
20
30
40
120 Additional
Power
110 Reserve
up
to 45°C
100
90
Δ –2.5 %
U [V]
U [V]
U out
U out
Δ –2.5 %
80
Power
Power
70
Reserve
Reserve
60
20 50
30 60
40 70
50 80
60
Ambient temperature [°C]
Ambient temperature [°C]
70
80
IN
I Reserve
IN
I [A]
I Reserve
t
Active current sharing
Uniform distribution of a load current
over two power supply units using
active current sharing.
•• A significant increase in the availability of the whole power supply
results as each power supply unit
only ever operates at a maximum of
half the nominal current.
TIP
Always use devices of the same
type. Active current sharing is
achieved using the redundancy
modules CP T RM10 and CP T
RM20.
PRO-M Output Power Derating Curve
Operating temperature, power
reserve and derating
Power supply units for industrial use
offer extended operating temperature
ranges (–25 to +70 °C). Up to the
­“derating” operating point, they have
power reserves, above this point they
can only be operated at reduced load.
•• Up to 45 °C, the device can be
­operated continuously with maximum of 120 % of rated current.
•• Up to 60 °C is 100 % of rated current
available.
U/I output characteristic with power reserve
Short-circuit and overload
The PRO-M power supply units follow the
IU output characteristic curve in the
event of a short-circuit/overload and are
therefore permanently short-circuit proof.
•• Compared to Hicc-up or foldback
characteristic curves, operation
with almost any capacitive loads is
possible.
•• PRO-M power supply units deliver a
constant 120 to 150 % of the nominal
current in short-circuit operation with
a simultaneously reduced voltage.
•• When the short-circuit or the overload is removed, there is a prompt
­return to normal operation.
Inrush current limit
Inrush current limiters improve the
dimensioning of the mains fuses
.
•• Power supply units from the lower
power classes mainly have a passive
inrush current limiter, e.g. PRO-M 3
A and 5 A models.
•• Power supply units with larger
power classes have an active inrush
current limiter, e.g. all 1-phase
PRO-M modules above 10 A.
I
Imax
Imax
Without active current limiting
With active current limiting
t
I
Selection chart
Power supplies
24
22.5…29.5
3
70
120%
yes, max. 5
l l
8951330000
80...370
24
22.5…29.5
5
120
120%
yes, max. 5
l l
8951340000
CP M SNT 180W 24V 7.5A**
l
85…264
47…63
80...370
24
22.5…29.5
7.5
180
120%
yes, max. 5
l l
8951350000
CP M SNT 250W 24V 10A**
l
85…264
47…63
80...370
24
22.5…29.5
10
240
120%
yes, max. 5
l l
8951360000
CP M SNT 500W 24V 20A**
l
85…264
47…63
80...370
24
22.5…29.5
20
480
120%
yes, max. 3
l l
8951370000
CP M SNT 1000W 24V 40A**
l
85…264
47…63
80...370
24
22.5…29.5
40
960
120%
yes, max. 3
l l
8951380000
CP M SNT 250W 24V 10A UW
l
85…264
47…63
80…430
24
22.5…29.5
10
240
120%
yes, max. 2
l l
1165480010
LED DC OK
Accessories
80...370
47…63
Status Relay
47…63
85…264
Power Boost
85…264
l
Rated Power
(W)
l
Three Phase
CP M SNT 70W 24V 3A**
Single Phase
Parallel
connection
option
Order-No.
Rated output
(A)
Appr. /Marks
Adjustable
Range (V)
Additional Features
DC (V)
Output Power
DC (V)
Output
Input
Frequence (Hz)
Output
CP M SNT 120W 24V 5A**
Description
PRO-M
PRO-H
INSTAPOWER
DC/DC converter
Input
AC (V)
Series / Family
CP M SNT3 120W 24V 5A**
l
320…575
47…63
450…870
24
22.5…29.5
5
120
120%
yes, max. 5
l l
8951390000
CP M SNT3 250W 24V 10A**
l
320…575
47…63
450…870
24
22.5…29.5
10
240
120%
yes, max. 5
l l
8951400000
CP M SNT3 500W 24V 20A**
l
320…575
47…63
450…870
24
22.5…29.5
20
480
120%
yes, max. 3
l l
8951410000
CP M SNT3 1000W 24V 40A**
l
320…575
47…63
450…870
24
22.5…29.5
40
960
120%
yes, max. 3
l l
8951420000
CP M DM20 (Diode module)* **
18…30
Input-0.7
n/a
l
l
1222210000
CP M DM40 (Diode module)* **
18…30
Input-0.7
n/a
l
l
1222220000
CP M RM24 (Relay module)*
18…30
n/a
l
l
1222230000
CP M CAP (Capacity module)* **
18…30
n/a
l
l
1222240000
CP T SNT 70W 12V 6A
l
85…264
47…63
n/a
12
12…14
6
72
l
yes, max. 5
l l
1105430000
CP T SNT 140W 12V 12A
l
85...132/187…264
47…63
n/a
12
12…14
12
144
l
yes, max. 5
l l
1105440000
CP T SNT 90W 24V 3.8A
l
85…264
47…63
n/a
24
24…28
3.8
90
l
yes, max. 5
l l
1105790000
CP T SNT 90W 24V 3.8A CL2
l
85…264
47…63
n/a
24
24…28
3.8
90
l
yes, max. 5
l l
1194410000
CP T SNT 180W 24V 7.5A
l
85...132/187…264
47…63
n/a
24
24…28
7.5
180
l
yes, max. 5
l l
1105810000
CP T SNT 360W 24V 15A
l
85...132/187…264
47…63
n/a
24
24…28
15
360
l
yes, max. 5
l l
1105820000
CP T SNT 600W 24V 25A
l
85...132/187…264
47…63
n/a
24
24…28
25
600
l
yes, max. 5
l l
1105840000
CP T SNT 600W 36V 16.5A
l
85...132/187…264
47…63
n/a
24
36…42
16.5
600
l
yes, max. 5
l l
1194430000
CP T SNT 90W 48V 2A
l
85..264
47…63
n/a
48
48…56
2
96
l
yes, max. 5
l l
1194420000
CP T SNT 180W 48V 4A
l
85...132/187…264
47…63
n/a
48
48…56
4
180
l
yes, max. 5
l l
1105850000
CP T SNT 360W 48V 7.5A
l
85...132/187…264
47…63
n/a
48
48…56
7.5
360
l
yes, max. 5
l l
1105860000
CP T SNT 600W 48V 12.5A
l
85...132/187…264
47…63
n/a
48
48…56
12.5
600
l
yes, max. 5
l l
1105870000
CP T SNT2 180W 24V 7.5A
l
85...132/187…550
50/60
n/a
24
24…28
7.5
180
l
yes
l l
1194480000
CP T SNT2 360W 24V 15A
l
85...132/187…550
50/60
n/a
24
24…28
15
360
l
yes
l l
1194490000
CP T SNT2 600W 24V 25A
l
85...132/187…550
50/60
n/a
24
24…28
25
600
l
yes
l l
1194310000
CP T RM 10 (Redundancy Module)*
24
24…27
l
l
1105880000
CP T RM 10 (Redundancy Module)*
24
24…27
l
l
1105880000
CP SNT 24W 28V 1A
l
85…265
50/60
120…300
28
n/a
1
28
CP SNT 24W 24V 1A
l
85…265
50/60
120…300
24
n/a
1
24
9928890028
9928890024
CP SNT 24W 15V 1.5A
l
85…265
50/60
120…300
15
n/a
1.5
17.5
9928890015
9928890012
CP SNT 24W 12V 1.5A
l
85…265
50/60
120…300
12
n/a
1.5
15
CP SNT 24W 5V 2A
l
85…265
50/60
120…300
5
n/a
2
10
CP SNT 25W 5V 5A
l
85…264
50/60
110…370
5
4…8
5
25
l
8754960000
CP SNT 48W 12V 4A
l
85…264
50/60
110…370
12
9…15
4
48
l
8754970000
CP SNT 48W 24V 2A
l
85…264
50/60
110…370
24
15…28
2
48
l
8739140000
CP SNT 48W 48V 1A
l
85…264
50/60
110…370
48
46…55
1
48
l
8879230000
CP DCDC 50W 22-24V DC 2A
18…30
22...24
2
50
l
9919372424
CP DCDC 50W 15V DC 3A
18…30
15
3
45
l
9919372415
CP DCDC 50W 12V DC 3A
9…16
12
3
36
l
9919371212
CP DCDC 50W 20-24V DC 2A
9…16
22...24
2
50
l
9919371224
CP DCDC 50W 15V DC 3A
9…16
15
3
45
l
9919371215
CP DCDC 50W 12V DC 3A
18…30
12
3
36
l
9919372412
CP DCDC 50W 5V DC 8A
18…30
5
8
40
l
9919372405
CP DCDC 250W 24V 10A
18...31.2
22.5...29.5
10
250
l
1313320010
* Accessories
** Optionally with a metal snap-on foot available
9928890005
Weidmüller – Partner in Industrial Connectivity.
As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
technological challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs.
Together we set standards in Industrial Connectivity.
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
Phone +49 5231 14-0
Fax
+49 5231 1429-2083
[email protected]
www.weidmueller.com
1366130000/05/2012/SMMD