Liebert Npower, 30-130, 220 or 240VA, 60Hz; Site Planning Data; (R11/04) (SL-24545)

Liebert has reinvented the
double-conversion
UPS. The Npower is
the result of an
international design
collaboration and
more than a decade
of advanced
research.
Every aspect of the
Npower shows
careful design and
attention to detail. The rugged
powertrain and advanced
ActiveStar™ controls were
subjected to computer simulations
and thermal analysis to ensure
reliable performance in every
environment.
Even the physical packaging is
uniquely efficient, to make fully
configured systems more compact
than other products on the market.
Best of all, it’s a Liebert product—
designed to give the same millionhour critical bus MTBF as its older
brothers.
• Unmatched heritage of
reliability and availability
• Smallest system footprint
• Excellent efficiency with nonlinear loads and partial loads
• Outstanding dynamic response
• All-digital ActiveStar™ controls
and graphical user interface
LIEBERT NPOWER™ 3-PHASE UPS: 30-130KVA, 60 HZ, 220 OR 240VAC
General Specifications
Npower Matching Battery Cabinet
Run Time (minutes) for kVA:
INPUT
Voltage
Voltage Range
Frequency Range
Current Distortion
Current Limit
Current Walk-in
Power Factor
Surge Protection
ENVIRONMENTAL
Operating
Temperature
Non-Operating Temp.
Relative Humidity
Operating Altitude
Acoustical Noise
220 or 240VAC, 60 Hz
3-phase, 3- or 4-wire plus ground
+10, -15%
(no battery discharge at -20%)
60 Hz, ±5
10% maximum reflected THD at full load with
optional input filter; 30% THD without filter
115% of full load input current
20 seconds to full load
0.80 lagging minimum at full load; up to 0.96
lagging at full load with optional input filter
Sustains input surges without damage, per
criteria listed in ANSI C62.41-1980 (IEEE 587)
UPS: 32° to 104°F (0-40°C)
Battery: 68° to 86°F (20-30°C)
-4° to 158°F (-20° to 70°C)
0-95% non-condensing
Up to 6600 ft. (2000m) without derating
Less than 65 dBA typical, measured
3.3 ft. (1m) from the unit
OUTPUT
Voltage
208, 220 or 480VAC
4-wire plus ground
Voltage Adjustment
Range
±5%
±0.5% for balanced load
±1.0% for 100% unbalanced load
±5% deviation for 100% load step
Dynamic Regulation ±1% for loss or return of AC input
Transient Response Recover to ±1% of steady state within 1 cycle
Time
For linear loads, 1% THD; less than 2.5% THD
Voltage Distortion
for 100% nonlinear loads w/o kVA/kW derating
120° ±0.5° for balanced load.
Phasing Balance
120° ±1° for 100% unbalanced load
Frequency
±0.1%
Regulation
Load Power
1.0 to 0.7 lagging without derating
Factor Range
125% of full load for 10 minutes
Overload
150% for 1 minute w/ true sinusoidal waveform
STANDARDS
ETL listed to UL 1778 UPS standards and CSA certified. Meets current
requirements for safe high performance UPS operation.
Voltage Regulation
Model
1FJ
1HJ
1LJ
1MJ
1PJ
1PJ(130)
1RJ
1UJ
1WJ
2PJ
Dimensions
30 40 50 65 80 100 130 WxDxH, in. (mm)
12
21
28
36
53
62
72
104
7
14
20
25
38
45
52
74
10
14
18
28
34
39
55
7
8
12
20
25
30
40
5
5
8
15
19
23
33
5
10 7
13 9
17 12
25 16
126 83 67 50 38 28
25x32.5x71
(635x825x1800)
49x32.5x71
(1250x825x1800)
204 145 108 78 63 48
6,000 (2,720)
(2) 49x32.5x71
(1250x825x1800)
6,700 (3,040)
7,400 (3,360)
8,000 (3,630)
10,100 (4,580)
(3) 25x32.5x71
635x825x1800)
9,000 (4,080)
35
39
48
69
(3) 49x32.5x71
(1250x825x1800)
10,050 (4,560)
11,100 (5,040)
12,000 (5,445)
15,150 (6,870)
-
(4) 25x32.5x71
(635x825x1800)
12,000 (5,440)
50
55
67
97
(4) 49x32.5x71
1250x825x1800
13,400 (6,080)
14,800 (6,720)
16,000 (7,260)
20,200 (9,160)
-
3PJ(130) 3RJ
223 161 129 94 72 54
3UJ
265 187 142 105 81 65
3WJ
421 302 217 157 124 94
4PJ
301 206 154 111 90 68
4PJ(130) 4RJ
329 224 182 134 102 77
4UJ
377 266 201 147 111 91
4WJ
480 423 320 222 180 135
lb. (kg)
1,600 (725)
1,800 (815)
2,350 (1,065)
2,350 (1,065)
3,000 (1,360)
3,350 (1,520)
3,700 (1,680)
4,000 (1,815)
5,050 (2,290)
(2) 25x32.5x71
635x825x1800)
-
2PJ(130) - 20
2RJ
144 104 76 55 45 35 25
2UJ
156 111 90 67 52 40 30
2WJ
- 97 74 55 40
3PJ
Weight
Maintenance Bypass Cabinets
Dimensions
Model
L or N
P or Q
WxDxH, in. (mm)
25x32.5x71
(635x825x1800)
31.7x32.5x71
(805x825x1800)
Weight, lb. (kg) for kVA:
30-50
65-80
100-130
660 (299)
750 (340)
800 (363)
1,210 (549)
1,320 (599)
1,540 (699)
Slim-Line Distribution Cabinet
Dimensions
Weight
kVA
WxDxH, in. (mm)
lb. (kg)
All
10x32.5x71
(254x825x1800)
250 (113)
Site Planning Data, Liebert Npower: 30-130kVA, 60 Hz, 220 or 240VAC
UPS
Rating
Voltage
kVA kW
Input
Output
30
24
220
208
30
24
220
220
30
24
240
208
30
24
240
240
40
32
220
208
40
32
220
220
40
32
240
208
40
32
240
240
50
40
220
208
50
40
220
220
50
40
240
208
50
40
240
240
65
52
220
208
65
52
220
220
65
52
240
208
65
52
240
240
80
64
220
208
80
64
220
220
80
64
240
208
80
64
240
240
100
80
220
208
100
80
220
220
100
80
240
208
100
80
240
240
130 104
220
208
130 104
220
220
130 104
240
208
130 104
240
240
See Notes for Table (below):
Standard AC Input
AC Input w/Filter Opt.
Current (A)
Current (A)
Rec.
Rec.
OCPD Nom.
OCPD
Nom.
Max.
Max.
87
108
150
75
94
125
87
108
150
75
94
125
79
99
125
69
86
125
79
99
125
69
86
125
115
144
175
100
125
150
115
144
175
100
125
150
106
132
175
92
115
150
106
132
175
92
115
150
144
180
225
125
157
200
144
180
225
125
157
200
132
165
200
115
144
175
132
165
200
115
144
175
183
229
300
161
202
250
183
229
300
161
202
250
168
210
250
148
185
225
168
210
250
148
185
225
225
281
350
198
248
300
225
281
350
198
248
300
206
258
350
182
227
300
206
258
350
182
227
300
280
350
450
247
308
400
280
350
450
247
308
400
256
321
400
226
283
350
256
321
400
226
283
350
364
455
600
321
401
500
364
455
600
321
401
500
333
417
500
294
368
450
333
417
500
294
368
450
1
2,3,8,12
6
1
2,3,8,12
6
Battery
Nom. Battery
VDC
kW
480
26
480
26
480
26
480
26
480
34
480
34
480
34
480
34
480
43
480
43
480
43
480
43
480
55
480
55
480
55
480
55
480
68
480
68
480
68
480
68
480
85
480
85
480
85
480
85
480
111
480
111
480
111
480
111
4
—
Notes for Table
1.
2.
3.
4.
5.
6.
7.
8.
9.
Max.
Discharge
66A
66A
66A
66A
88A
88A
88A
88A
109A
109A
109A
109A
141A
141A
141A
141A
174A
174A
174A
174A
218A
218A
218A
218A
283A
283A
283A
283A
1,3,5,8,12
Nominal (Nom) current is based on full rated output load.
Maximum (Max) current (125% of nominal) is short duration for battery recharge conditions.
UPS input and bypass cables must be run in separate conduit from output cables.
Nominal battery voltage is shown at 2.0 volts/cell per NEC 480-2.
Power cables from UPS DC link to batteries should be sized for a total maximum 2.0V line drop
(measured at the UPS) at maximum discharge current.
OCPD=Overcurrent Protection Device. Recommended AC input and AC output overcurrent protection
represents 125% of nominal full load current (continuous) per NEC 215.
Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are
recommended. Neutral conductors to be sized for full capacity per NEC 310-15(b)(4). References are per
NEC 1999.
Wiring requirements:
AC Input and Output: 3-phase, 3- or-4-wire plus ground, depending on UPS configuration. See
installation manual and submittal drawings for specific instructions. DC Input: 2-wire (positive and
negative), plus ground.
All wiring is to be in accordance with national and local electrical codes.
10.
11.
12.
13.
14.
15.
16.
17.
AC Output
Current
Nom
OCPD
83
125
79
100
83
125
72
100
111
150
105
150
111
150
96
125
139
175
131
175
139
175
120
150
180
225
171
225
180
225
156
200
222
300
210
300
222
300
192
250
278
350
262
350
278
350
241
300
361
450
341
450
361
450
313
400
1,3,8,12
6
Mechanical Data
Dimensions
WxDxH, in. (mm)
Weight
lb. (kg)
Floor Loading
lb./ft2 (kg/m2)
Heat Dis.
BTU/h (kWH)
Cooling Air
CFM (m3/h)
31.7x32.5x71
(805x825x1800)
2,100 (953)
294 (1435)
8500 (2.5)
720 (1223)
31.7x32.5x71
(805x825x1800)
2,200 (998)
307 (1499)
11,000 (3.2)
720 (1223)
31.7x32.5x71
(805x825x1800)
2,200 (998)
307 (1499)
14,000 (4.1)
720 (1223)
39.4x32.5x71
(1001x825x1800)
2,500 (1134)
281 (1372)
18,000 (5.3)
960 (1631)
39.4x32.5x71
(1001x825x1800)
2,500 (1134)
281 (1372)
22,000 (6.4)
960 (1631)
49.2x32.5x71
(1250x825x1800)
3,350 (1520)
302 (1474)
26,000 (7.6)
1440 (2447)
49.2x32.5x71
(1250x825x1800)
3,350 (1520)
302 (1474)
33,000 (9.7)
1440 (2447)
13
13, 14
—
—
—
Minimum access clearance is 3 ft. (0.9m) front and 1 ft. (0.3m) above UPS.
Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then
replace.
Control wiring and power wiring must be run in separate conduit.
Weights and dimensions shown do not include ancillary cabinets or other options.
Add 560 lb. (254kg) for 100-130kVA unit with dual input and isolated 208VAC output.
Backup emergency generator must be properly sized and equipped with an isochronous governor
(generator frequency regulation) and a UPS-compatible voltage regulator.
An on-site automatic transfer switch should be equipped with auxiliary contacts for UPS “on generator”
current limit. Refer to Liebert publication 91K-PLT-48-02.
An external isolated maintenance bypass circuit might cause utility AC input to be out of phase with the
UPS AC output.
© 2004 Liebert Corporation
All rights reserved throughout the world. Specifications subject to change without notice.
® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are
trademarks or registered trademarks of their respective owners.
SL-24545 (11/04) Rev. 4
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Telephone: 1-800-877-9222
Facsimile: 1-614-841-6022
www.liebert.com