Liebert Npower, 30-130kVa, 208 / 480VAC, 60Hz; Site Planning Data; (R11/04) (SL-24531)

Liebert has reinvented the
double-conversion
UPS. The Npower is
the result of an
international design
collaboration and
more than a decade
of advanced
research.
Every aspect of the
Npower shows
careful design and
attention to detail. The rugged
powertrain and advanced
ActiveStar™ controls were
subjected to computer simulations
and thermal analysis to ensure
reliable performance in every
environment.
Even the physical packaging is
uniquely efficient, to make fully
configured systems more compact
than other products on the market.
Best of all, it’s a Liebert product—
designed to give the same millionhour critical bus MTBF as its older
brothers.
• Unmatched heritage of
reliability and availability
• Smallest system footprint
• Excellent efficiency with nonlinear loads and partial loads
• Outstanding dynamic response
• All-digital ActiveStar™ controls
and graphical user interface
LIEBERT NPOWER™ 3-PHASE UPS: 30-130KVA, 60 HZ, 208 OR 480VAC
General Specifications
Npower Matching Battery Cabinet
Run Time (minutes) for kVA:
INPUT
Voltage
Voltage Range
Frequency Range
Current Distortion
Current Limit
Current Walk-in
Power Factor
Surge Protection
ENVIRONMENTAL
Operating
Temperature
Non-Operating Temp.
Relative Humidity
Operating Altitude
Acoustical Noise
208 or 480VAC, 60 Hz
3-phase, 3- or 4-wire plus ground
+10, -15%
(no battery discharge at -20%)
60 Hz, ±5
10% maximum reflected THD at full load with
optional input filter; 30% THD without filter
115% of full load input current
20 seconds to full load
0.80 lagging minimum at full load; up to 0.96
lagging at full load with optional input filter
Sustains input surges without damage, per
criteria listed in ANSI C62.41-1980 (IEEE 587)
UPS: 32° to 104°F (0-40°C)
Battery: 68° to 86°F (20-30°C)
-4° to 158°F (-20° to 70°C)
0-95% non-condensing
Up to 6600 ft. (2000m) without derating
Less than 65 dBA typical, measured
3.3 ft. (1m) from the unit
OUTPUT
Voltage
208 or 480VAC
3-phase, 4-wire plus ground
Voltage Adjustment
Range
±5%
±0.5% for balanced load
±1.0% for 100% unbalanced load
±5% deviation for 100% load step
Dynamic Regulation ±1% for loss or return of AC input
Transient Response Recover to ±1% of steady state within 1 cycle
Time
For linear loads, 1% THD; less than 2.5% THD
Voltage Distortion
for 100% nonlinear loads w/o kVA/kW derating
120° ±0.5° for balanced load.
Phasing Balance
120° ±1° for 100% unbalanced load
Frequency
±0.1%
Regulation
Load Power
1.0 to 0.7 lagging without derating
Factor Range
125% of full load for 10 minutes
Overload
150% for 1 minute w/ true sinusoidal waveform
STANDARDS
ETL listed to UL 1778 UPS standards and CSA certified. Meets current
requirements for safe high performance UPS operation.
Voltage Regulation
Model
1FJ
1HJ
1LJ
1MJ
1PJ
1PJ(130)
1RJ
1UJ
1WJ
2PJ
Dimensions
30 40 50 65 80 100 130 WxDxH, in. (mm)
12
21
28
36
53
62
72
104
7
14
20
25
38
45
52
74
10
14
18
28
34
39
55
7
8
12
20
25
30
40
5
5
8
15
19
23
33
5
10 7
13 9
17 12
25 16
126 83 67 50 38 28
25x32.5x71
(635x825x1800)
49x32.5x71
(1250x825x1800)
204 145 108 78 63 48
6,000 (2,720)
(2) 49x32.5x71
(1250x825x1800)
6,700 (3,040)
7,400 (3,360)
8,000 (3,630)
10,100 (4,580)
(3) 25x32.5x71
635x825x1800)
9,000 (4,080)
35
39
48
69
(3) 49x32.5x71
(1250x825x1800)
10,050 (4,560)
11,100 (5,040)
12,000 (5,445)
15,150 (6,870)
-
(4) 25x32.5x71
(635x825x1800)
12,000 (5,440)
50
55
67
97
(4) 49x32.5x71
1250x825x1800
13,400 (6,080)
14,800 (6,720)
16,000 (7,260)
20,200 (9,160)
-
3PJ(130) 3RJ
223 161 129 94 72 54
3UJ
265 187 142 105 81 65
3WJ
421 302 217 157 124 94
4PJ
301 206 154 111 90 68
4PJ(130) 4RJ
329 224 182 134 102 77
4UJ
377 266 201 147 111 91
4WJ
480 423 320 222 180 135
lb. (kg)
1,600 (725)
1,800 (815)
2,350 (1,065)
2,350 (1,065)
3,000 (1,360)
3,350 (1,520)
3,700 (1,680)
4,000 (1,815)
5,050 (2,290)
(2) 25x32.5x71
635x825x1800)
-
2PJ(130) - 20
2RJ
144 104 76 55 45 35 25
2UJ
156 111 90 67 52 40 30
2WJ
- 97 74 55 40
3PJ
Weight
Maintenance Bypass Cabinets
Dimensions
Model
L or N
P or Q
WxDxH, in. (mm)
25x32.5x71
(635x825x1800)
31.7x32.5x71
(805x825x1800)
Weight, lb. (kg) for kVA:
30-50
65-80
100-130
660 (299)
750 (340)
800 (363)
1,210 (549)
1,320 (599)
1,540 (699)
Slim-Line Distribution Cabinet
Dimensions
Weight
kVA
WxDxH, in. (mm)
lb. (kg)
All
10x32.5x71
(254x825x1800)
250 (113)
Site Planning Data, Liebert Npower: 30-130kVA, 60 Hz, 208 or 480VAC
Standard AC
UPS
Rating
Voltage
Current (A)
kVA kW Input
Output Nom. Max.
30
24
208
208
92
114
30
24
480
208
38
48
30
24
480
480
38
48
40
32
208
208
122
153
40
32
480
208
51
64
40
32
480
480
51
64
50
40
208
208
153
191
50
40
480
208
64
80
50
40
480
480
64
80
65
52
208
208
193
242
65
52
480
208
80
99
65
52
480
480
80
99
80
64
208
208
238
298
80
64
480
208
98
122
80
64
480
480
98
122
100
80
208
208
296
370
100
80
480
208
122
152
100
80
480
480
122
152
130 104
208
208
385
481
130 104
480
208
158
198
130 104
480
480
158
198
See Notes for Table (below):
1 2,3,8,12
Input
AC Input w/Filter Opt.
Battery
AC Output
Current (A)
Current
Rec.
Rec. Nom. Battery
Max.
OCPD Nom. Max. OCPD VDC
kW
Discharge Nom OCPD
150
80
99
125
480
26
66A
83
125
60
33
41
50
480
26
66A
83
125
60
33
41
50
480
26
66A
36
50
200
106
133
175
480
34
88A
111
150
80
44
55
70
480
34
88A
111
150
80
44
55
70
480
34
88A
48
60
250
133
166
200
480
43
109A
139
175
100
55
69
100
480
43
109A
139
175
100
55
69
100
480
43
109A
60
80
300
171
213
300
480
55
141A
180
225
125
70
88
125
480
55
141A
180
225
125
70
88
125
480
55
141A
78
10
400
210
262
350
480
68
174A
222
300
150
87
108
150
480
68
174A
222
300
150
87
108
150
480
68
174A
96
125
450
261
326
400
480
85
218A
278
350
200
108
135
175
480
85
218A
278
350
200
108
135
175
480
85
218A
120
150
600
336
420
500
480
111
283A
361
450
250
140
175
225
480
111
283A
361
450
250
140
175
225
480
111
283A
156
200
6,14
1
2,3,8,12
6
4
—
1,3,5,8,12 1,3,8,12
6
Notes for Table
1.
2.
3.
4.
5.
6.
7.
8.
9.
Nominal (Nom) current is based on full rated output load.
Maximum (Max) current (125% of nominal) is short duration for battery recharge
conditions.
UPS input and bypass cables must be run in separate conduit from output cables.
Nominal battery voltage is shown at 2.0 volts/cell per NEC 480-2.
Power cables from UPS DC link to batteries should be sized for a total maximum 2.0V line
drop (measured at the UPS) at maximum discharge current.
OCPD=Overcurrent Protection Device. Recommended AC input and AC output overcurrent
protection represents 125% of nominal full load current (continuous) per NEC 215.
Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground
conductors are recommended. Neutral conductors to be sized for full capacity per
NEC 310-15(b)(4). References are per NEC 1999.
Wiring requirements:
AC Input and Output: 3-phase, 3- or-4-wire plus ground, depending on UPS configuration.
See Installation Manual and submittal drawings for specific instructions.
DC Input: 2-wire (positive and negative), plus ground.
All wiring is to be in accordance with national and local electrical codes.
Mechanical Data
Dimensions
WxDxH, in. (mm)
31.7x32.5x71
(805x825x1800)
31.7x32.5x71
(805x825x1800)
31.7x32.5x71
(805x825x1800)
39.4x32.5x71
(1001x825x1800)
39.4x32.5x71
(1001x825x1800)
49.2x32.5x71
(1250x825x1800)
49.2x32.5x71
(1250x825x1800)
Heat Dis.
BTU/h (kWH)
8,500 (2.5)
7,500 (2.2)
7,500 (2.2)
11,000 ((3.2)
10,000 (2.9)
10,000 (2.9)
14,000 (4.1)
12,000 (3.5)
12,000 (3.5)
18,000 (5.3)
15,000 (4.4)
15,000 (4.4)
22,000 (6.4)
18,000 (5.3)
18,000 (5.3)
26,000 (7.6))
21,000 (6.1)
21,000 (6.1)
33,000 (9.7)
27,000 (7.9)
27,000 (7.9)
—
Cooling Air
CFM (m3/h)
720 (1223)
720 (1223)
720 (1223)
960 (1631)
960 (1631)
1440 (2447
1440 (2447)
—
10. Minimum access clearance is 3 ft. (0.9m) front and 1 ft. (0.3m) above UPS.
11. Top or bottom cable entry through removable access plates. Punch plate to suit conduit
size, then replace.
12. Control wiring and power wiring must be run in separate conduit.
13. Weights and dimensions shown do not include battery cabinet, Slim-Line distribution
cabinet or other options.
14. Add 560 lb. (254kg) for 100-130kVA unit with dual input and isolated 208VAC output.
15. Backup emergency generator must be properly sized and equipped with an isochronous
governor (generator frequency regulation) and a UPS-compatible voltage regulator.
16. An on-site automatic transfer switch should be equipped with auxiliary contacts for UPS
“on generator” current limit. Refer to Liebert publication 91K-PLT-48-02.
17. An external isolated maintenance bypass circuit might cause utility AC input to be out of
phase with the UPS AC output.
© 2004 Liebert Corporation
All rights reserved throughout the world. Specifications subject to change without notice.
® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names
referred to are trademarks or registered trademarks of their respective owners.
SL-24531 (11/04) Rev. 4
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
13
Weight Floor Loading
lb. (kg)
lb./ft2 (kg/m2)
2100 (953) 294 (1435)
259 (1265)
1850 (839)
259 (1265)
2200 (998) 307 (1499)
266 (1299)
1900 (862)
266 (1299)
2200 (998) 307 (1499)
266 (1299)
1900 (862)
266 (1299)
2500 (1134) 281 (1372)
242 (1182)
2150 (975)
242 (1182)
2500 (1134) 281 (1372)
242 (1182)
2150 (975)
242 (1182)
3350 (1520) 302 (1474)
252 (1230)
2800 (1270)
252 (1230)
3350 (1520) 302 (1474)
252 (1230)
2800 (1270)
252 (1230)
13, 14
—
Telephone: 1-800-877-9222
Facsimile: 1-614-841-6022
www.liebert.com