PDF Data Sheet Rev. B

This specification documents the detail requirements for space qualified die per MIL-PRF-38534 class K
except as modified herein.
The manufacturing flow described in the SPACE DIE BROCHURE is to be considered a part of this
specification.
This datasheet specifically details the space grade version of this product. A more detailed operational
description and a complete datasheet for commercial product grades can be found at
www.analog.com/HMC346
The complete part number(s) of this specification follow:
Part Number
HMC8801
Description
MMIC Voltage-Variable Attenuator DC-20GHz Die
1. RF1 Input (DC coupled, matched to
50 ohms)*
2. RF2 Output (DC coupled, matched
to 50 ohms)*
3. V2 (Control input, master)
4. I (Control input, slave)
5. 500 (This pad must be DC
grounded)
6. V1 (Control input, master)
7. O (DO NOT CONNECT)



Die bottom must be connected to RF
GND
*Blocking capacitors required if RF
line potential is not equal to 0V
No connection required for unlabeled
bond pads
Control Voltage Range ........................................................... +1 to -5 VDC
RF input power (RFIN) ..................................................................+18 dBm
Ambient Operating Temperature Range (TA).....................-40C to +85C
Storage Temperature ........................................................-65C to +150C
ESD Sensitivity (HBM) .................................................................. Class 1A
Absolute Maximum Ratings Notes:
1/
Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
In accordance with class-K version of MIL-PRF-38534, Appendix C, Table C-II, except as modified
herein.
(a) Qual Sample Size and Qual Acceptance Criteria – 10/0
(b) Pre-screen test post assembly required prior to die qualification, to remove all assembly related
rejects.
(c) Mechanical Shock or Constant Acceleration not performed; die qualification is performed in an
open carrier .
(d) Max die qualification temperature limited to +85C
Table I Notes:
1.
2.
3.
Limits apply at +25C only.
Min and Max Attenuation tested only with VCTL = 0/-3 V.
S-par data to be taken at 50 MHz, 1 GHz, 3 GHz, 6 GHz, 12 GHz, 16 GHz, and 20 GHz. Pin = -25 dBm
Table II Notes:
1/
2/
3/
4/
5/
Pre burn-in and Post burn-in electrical require S-parameter testing only as defined. Final electrical tests shall incorporate power tests as defined.
Temperature testing required for Final Electrical testing only
Min and Max Attenuation tested only with VCTL = 0/-3V.
S-par data to be tabulated at 50 MHz, 1 GHz, 3 GHz, 6 GHz, 12 GHz, 16 GHz, and 20 GHz. Pin = -25 dBm
P0.25dB and IP3 shall be measured at 0.5 GHz, 3 GHz, 6 GHz, 12 GHz, and 20 GHz at Min Attenuation only
Table III Notes:
1/ Table II limits will not be exceeded
2/ 240 hour burn in and Group C end point electrical parameters. Deltas are performed at TA = 25°C
1. RF1 Input (DC coupled, matched to
50 ohms)*
2. RF2 Output (DC coupled, matched
to 50 ohms)*
3. V2 (Control input, master)
4. I (Control input, slave)
5. 500 (This pad must be DC
grounded)
6. V1 (Control input, master)
7. O (DO NOT CONNECT)



Die bottom must be connected to RF
GND
*Blocking capacitors required if RF
line potential is not equal to 0V
No connection required for unlabeled
bond pads