View PDF

FINAL PRODUCT/PROCESS CHANGE NOTIFICATION
Generic Copy
18-FEB-2003
SUBJECT: ON Semiconductor Final Product/Process Change Notification #12751
TITLE: Qualification of Additional VHVIC Devices (NCP105X SER) at the Aizu, Japan Facility.
EFFECTIVE DATE: 19-Apr-2003
AFFECTED CHANGE CATEGORY:
ON SEMICONDUCTOR FAB SITE
WAFER PROCESS
DIE SHRINK
DESIGN CHANGE
AFFECTED PRODUCT DIVISION: Analog Products
ADDITIONAL RELIABILITY DATA: Available
Contact your local ON Semiconductor Sales Office or Rick Luevanos <[email protected]>
SAMPLES: Contact your local ON Semiconductor Sales Office or
Jack Cartwright <[email protected]>
FOR ANY QUESTIONS CONCERNING THIS NOTIFICATION:
Contact Sales Office or Jack Cartwright <[email protected]>
DISCLAIMER:
Final Product/Process Change Notification (FPCN) - Final Notification completing the notification
process. Distributed at least 60 days from the effective date of the change. ON Semiconductor will
consider this change approved unless specific conditions of acceptance are provided in writing within
30 days of receipt of this notice. To do so, contact your local ON Semiconductor Sales Office.
DESCRIPTION AND PURPOSE:
This is the final PCN ( Product Change Notification) to notify customers of the qualification of
additional VHVIC devices on the 6-inch wafer production line at ON's facility in Aizu, Japan.
Evaluation of the devices in their intended applications reveals no change in functionality. However,
ON Semiconductor recommends that our valued customers evaluate 6 inch material in their specific
applications. Samples will be provided upon request.
Issue Date: 18 Feb, 2003
Page 1 of 3
Final Product/Process Change Notification #12751
RELIABILITY DATA SUMMARY:
The following devices have successfully passed the qualification tests below on 6inch process :
DEVICE: NCP1053P136
TEST
HTOL
HTBB
TC
HAST
UHAST
AC
CONDITIONS
125DegC, 1000Hrs
125DegC, 600V bias on HV pin , 1000Hrs
-65DegC to 150DegC, 500 cycles
130DegC, 85%RH,bias, 96Hrs
130DegC, 85%RH, 96Hrs
121DegC, 100%RH, 15 psig, 96Hrs
SS
240
240
240
240
240
240
Results
0 failures
2 failures*
0 failures
0 failures
0 failures
0 failure
* FA found a random low level fab etch defect : 8D done and corrective action in place . 8D available
upon request. The second unit was destroyed during analysis before a root cause could be identified.
ELECTRICAL CHARACTERISTIC SUMMARY:
The following specification changes are being implemented for clarification and standardization
purposes.
NCP1050, NCP1051, NCP1052, NCP1053, NCP1054, NCP1055
ELECTRICAL CHARACTERISTICS
Power Switch Circuit
Symbol
Power Switch Circuit &
Ids(off)
Startup Circuit Off-State Leakage Current
Tj=25C (Vds=700V)
Tj=125C (Vds=700V)
Tj=25C (Vds=650V)
Tj=125C (Vds=650V)
Min
Typ
Max
Unit
uA
-
25
15
25
15
40
80
40
80
Startup /
Vcc (on)
Vcc Regulation Peak(Vcc Increasing)
8.20
8.00
8.60
8.50
9.00
9.00
V
Current Spec
Revised Spec
Minimum Operating /
Vcc (off)
Vcc Valley Voltage After Turn-On
7.20
7.00
7.60
7.50
8.00
8.00
V
Current Spec
Revised Spec
Undervoltage Lockout
Vcc(reset)
Threshold Voltage,Vcc Decreasing
4.20
4.00
4.60
4.50
5.00
5.00
V
Current Spec
Revised Spec
Startup Circuit Output Current
(Vcc=0V, Tj=25C)
(Vd=40V)
Istart
5.4
6.2
7.0
mA
Current Spec
5.4
6.3
7.2
Startup Circuit Output Current
(Vcc=Vcc(on)-0.2V, Tj=25C)
(Vd=40V)
Istart
4.6
5.4
6.2
4.6
5.6
6.6
3.5
-
7.0
3.5
-
7.5
Current Spec
Current Spec
Revised Spec
Revised Spec
Startup Control
Startup Circuit Output Current
Istart
(Vcc=Vcc(on)-0.2V, Tj=-40 to 125C)
(Vd=40V)
Issue Date: 18 Feb, 2003
Revised Spec
mA
Current Spec
Revised Spec
mA
Current Spec
Revised Spec
Page 2 of 3
Final Product/Process Change Notification #12751
Control Input
Control Window Input Voltage
Lower (Isink=25uA)
Vlow
1.15
1.10
1.30
1.35
1.45
1.60
V
Current Spec
Revised Spec
Icc1
0.45
0.56
0.65
mA
Current Spec
0.40
0.55
0.65
Total Device
Power Supply Current
After UVLO Turn-On
Power Switch Circuit Enabled
(NCP1050,NCP1051, NCP1052)
(C suffix Device)
Revised Spec
All other electrical parameters remain unchanged.
CHANGED PART IDENTIFICATION:
Parts will have Date Code of 0314 or later.
AFFECTED DEVICE LIST (WITHOUT SPECIALS):
PART
NCP1050P136
NCP1050P44
NCP1051P100
NCP1051P136
NCP1051P44
NCP1052P100
NCP1052P136
NCP1052P44
NCP1053P100
NCP1053P136
NCP1053P44
NCP1054P100
NCP1054P136
NCP1054P44
NCP1055P100
NCP1055P136
NCP1055P44
Issue Date: 18 Feb, 2003
Page 3 of 3