Hall Effect Current Sensors w w w. t a m u r a c o r p . c o m 100 to 300 Amp Applications –– Closed Loop • PCB Mount Design • Current Output type • Very High Linearity • ±15V Supply Voltage • CE EN50178 (pending) Specifications Measured at 25˚C, RL-10KΩ, VCC=+15V Specification 1 2 3 S21Z100D15 S21Z150D15 S21Z200D15 S21Z300D15 Nominal Primary DC Current (If) 100A 150A 200A Maximum Current If(max) 150A 225A 300A 450A Output Current @ If IOUT 50mA 75mA 100mA 150mA Conversion Ratio Kn X 1:2000 1:2000 1:2000 1:2000 Accuracy Offset Current (If=0)1 Io ±1% of If ±0.5mA Output Linearity1 (0..If) EL ±0.25% of If Power Supply Vcc ±15V ±5%2 Response Time tr < 1µs Current Consumption Ic ±16mA 3 Output Temperature Characteristic TCIOUT ±0.025% / °C @ If=0 (Ta=-5 to +70°C) Offset Temperature Characteristic IOT ±0.025mA / °C @ If=0 (Ta=-5 to +70°C) Hysteresis Allowance If=0 - Ifmax) IOH < 0.3mA Withstand Voltage (50/60Hz) Vd 2,500VACrms for 1 minute (sensing current 0.5mA) Insulation Resistance @ 500VDC RIS 500MΩ Frequency Bandwidth (-3dB) f DC - 150kHz Operating Temperature TA -10 - +70°C Storage Temperature TS -20 - +85°C Secondary Coil Resistance Rs TBD Ohms @ Ta = 70°C (Contact Tamura for additional info) 300A Without Offset Ifmax is Restricted by Vcc Output Current not included Package & Weight Information Weight/each(g) 50 25 Current Sense Products QTY/Box TA M U R A C O R P O R AT I O N 43352 Business Park Drive. | USA Tel: 800-872-6624 Fax: 909-676-9482 P.O. Box 892230 Temecula, CA 92589-2230 | www.tamuracorp.com Japan Tel: 81 (0)3 3978-2111 Fax: 81 (0)3 3923-0230 United Kingdom Tel: 44 (0) 1380 731 700 Fax: 44 (0) 1380 731 702 Hong Kong Tel: 852-2389-4321 Fax: 852-2341-9689 84 Hall Effect Current Sensors w w w. t a m u r a c o r p . c o m 50 to 300 Amp Applications –– Closed Loop • Panel Mount Design • Current Output type • Very High Linearity • +12V or +15V Supply Voltage • CE EN50178 (pending) Specifications Measured at 25˚C, RL±15KΩ, Vcc=+12V Specification 1 2 3 4 S20S050A S20S100A S20S150A S20S200A S20S300A Nominal Primary DC Current (If) 50A 100A 150A 200A 300A Maximum Current If(max) 75A 150A 225A 300A 450A Output Current @ If IOUT 50mA 100mA 150mA 100mA 150mA Conversion Ratio KN 1:1000 1:1000 1:1000 1:2000 1:2000 Offset Current (If=0) Io ±0.5mA Accuracy 4 X < ±1% of If Output Linearity 4 (0..MAX) EL ±0.25% Power Supply Vcc 12V or ±15V ±5% 2 Response Time @ di/dt=50A/uSec tr ≤ 1µs Current Consumption Ic ±16mA 3 Output Temperature Characteristic TCIOUT ±0.02% / °C @ If (Ta=-5 to +70°C) Offset Temperature Characteristic IOT ±0.025mA / °C @ If=0 (Ta=-5 to +70°C) Hysteresis Allowance IOH ≤ 0.5mA Withstand Voltage (50/60Hz) Vd 2,500VACrms for 1 minute (sensing current 0.5mA) Insulation Resistance @ 500VDC RIS ≥500MΩ Frequency Bandwidth (-3dB) f DC - 150kHz Operating Temperature TA -10 - +70°C Storage Temperature TS Secondary Coil Resistance RS -20 - +85°C 1 Ohms @ 70°C (Contact Tamura Tech Support) TBD Ifmax is Restricted by Vcc Output Current not included Without offset Current Sense Products Package & Weight Information QTY/Box Weight/each(g) TBD 46 TA M U R A C O R P O R AT I O N 43352 Business Park Drive. | 85 USA Tel: 800-872-6624 Fax: 909-676-9482 P.O. Box 892230 Temecula, CA 92589-2230 | www.tamuracorp.com Japan Tel: 81 (0)3 3978-2111 Fax: 81 (0)3 3923-0230 United Kingdom Tel: 44 (0) 1380 731 700 Fax: 44 (0) 1380 731 702 Hong Kong Tel: 852-2389-4321 Fax: 852-2341-9689 Hall Effect Current Sensors w w w. t a m u r a c o r p . c o m 6 to 25 Amp Applications –– Closed Loop • Multirange Current Sensor • Voltage Output • Compact PCB Mount • Single Supply (+5V) • CE EN50178 (pending) Specifications Measured at 25˚C, RL-10KΩ, Vcc=+5V Specification S22P006S05 S22P025S05 Nominal Primary r.m.s. Current (If) ±6A ±15A ±25A Maximum Current If(max) ±18A ±45A ±75A Offset Voltage (If=0) VREF 2.5V±30mV 2.5V±20mV 2.5V±15mV Output Voltage VOUT VREF ± 0.625V Output Voltage Accuracy1 @ If X 0.625V ±10mV Output Linearity (0 to If) EL ±0.25% Power Supply Vcc ±5V±5% Response Time tr ≤1µs Current Consumption IC 12.5mA Typ Output Temperature Characteristic ICEG Offset Temperature Characteristic TCVOUT ±0.05mV/°C 1.25mV/°C 1.25mV/°C 1.25mV/°C ≤ 0.25mV Hysteresis Allowance (If=0 to Ifmax) VOH 1 S22P015S05 Withstand Voltage (50/60Hz) Vd Insulation Resistance @ 500VDC RIS 3,000VACrms for 1 minute (sensing current 0.5mA) ≥500MΩ Operating Bandwidth (1dB) f DC - 200kHz Operating Temperature TA -10 - +85°C Storage Temperature TS -25 - +100°C Without offset Package & Weight Information QTY/Box Weight/each(g) 100 8 Current Sense Products TA M U R A C O R P O R AT I O N 43352 Business Park Drive. | USA Tel: 800-872-6624 Fax: 909-676-9482 P.O. Box 892230 Temecula, CA 92589-2230 | www.tamuracorp.com Japan Tel: 81 (0)3 3978-2111 Fax: 81 (0)3 3923-0230 United Kingdom Tel: 44 (0) 1380 731 700 Fax: 44 (0) 1380 731 702 Hong Kong Tel: 852-2389-4321 Fax: 852-2341-9689 86