TI TPS3803-01

TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
features
typical applications
D Single Voltage Detector (TPS3803):
D Applications Using DSPs, Microcontrollers,
D
D
D
D
D
D
Adjustable/1.5 V
Dual Voltage Detector (TPS3805):
Adjustable/3.3 V
High ±1.5% Threshold Voltage Accuracy
Supply Current: 3 µA Typical at VDD = 3.3 V
Push/Pull Reset Output (TPS3805)
Open-Drain Reset Output (TPS3803)
Temperature Range . . . –40°C to 85°C
Five-Pin SC–70 Package
D
D
D
D
D
D
D
or Microprocessors
Wireless Communication Systems
Portable/Battery-Powered Equipment
Programmable Controls
Intelligent Instruments
Industrial Equipment
Notebook/Desktop Computers
Automotive Systems
DCK PACKAGE
(TOP VIEW)
description
TPS3803-01, TPS3803G15, TPS3805
The TPS3803 and TPS3805 families of supervisory circuits provide circuit initialization and timing
supervision, primarily for DSPs and processorbased systems.
The TPS3803G15 device has a fixed-sense
threshold voltage VIT set by an internal voltage
divider, whereas the TPS3803–01 has an
adjustable SENSE input that can be configured by
two external resistors. In addition to the fixed
sense threshold monitored at VDD, the TPS3805
devices provide a second adjustable SENSE
input. RESET is asserted in case any of the two
voltages drops below VIT.
During power on, RESET is asserted when supply
voltage VDD becomes higher than 0.8 V.
Thereafter, the supervisory circuit monitors VDD
(and/or SENSE) and keeps RESET active as long
as VDD or SENSE remains below the threshold
voltage VIT. As soon as VDD (SENSE) rises above
the threshold voltage VIT, RESET is deasserted
again. The product spectrum is designed for
1.5 V, 3.3 V, and adjustable supply voltages. The
devices are available in a five-pin SC-70 package.
The TPS3803 and TPS3805 devices are
characterized for operation over a temperature
range of –40°C to 85°C.
NC
1
GND
2
RESET
3
5
SENSE
NC{
4
VDD
{TPS3803G15
typical operating circuit
1.6 V
3.3 V
DVDD
R1
RESET
VDD
TPS3805H33
SENSE
R2
GND
CVDD
RESET
TMS320VC5416
GND
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  2001, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
PACKAGE INFORMATION
THRESHOLD VOLTAGE
TA
DEVICE NAME
–40_C
40 C to 85_C
85 C
MARKING
TPS3803–01DCKR†
TPS3803G15DCKR†
VDD
NA
SENSE
1.226 V
1.40 V
NA
AWI
TPS3805H33DCKR†
3.05 V
1.226 V
AWK
AWG
† The DCKR passive indicates tape and reel containing 3000 parts.
ordering information
TPS380
3
G
15
DCK R
Reel
Package
Nominal Supply Voltage
Nominal Threshold Voltage
Functionality
Family
Function/Truth Tables
TPS3803-01
TPS3803G15
SENSE > VIT
RESET
L
VDD > VIT
0
RESET
0
1
H
1
H
L
TPS3805H33
2
VDD > VIT
0
SENSE > VIT
RESET
0
L
0
1
L
1
0
L
1
1
H
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
functional block diagram
TPS3803G15
R1
VDD
VDD
RESET
_
TPS3803–01
Device
Supply Voltage
SENSE
+
_
RESET
+
R2
GND
GND
Reference
Voltage
of 1.215 V
Reference
Voltage
of 1.226 V
TPS3805
_
SENSE
+
R1
VDD
RESET
_
+
R2
GND
Reference
Voltage
of 1.226 V
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
timing requirements
VDD or SENSE
VIT + Vhys
VIT
0.8 V
RESET
= Undefined
Terminal Functions
TERMINAL
NAME
NO.
I/O
DESCRIPTION
GND
2
I
Ground
RESET
3
O
Active-low reset output (TPS3803—open–drain, TPS3805—push/pull)
SENSE
5
I
Adjustable sense input
NC
1
No internal connection
NC (TPS3803G15)
5
No internal connection
VDD
4
4
I
Input supply voltage, fixed sense input for TPS3803G15 and TPS3805
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VDD (see Note1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
All other pins (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V
Maximum low-output current, IOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 mA
Maximum high-output current, IOH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –5 mA
Input clamp current, IIK (VI<0 or VI>VDD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 mA
Output clamp current, IOK (VO<0 or VO>VDD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 mA
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
Soldering temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND. For reliable operation the device should not be continuously operated at 7 V for more than
t=1000 h.
DISSIPATION RATING TABLE
PACKAGE
TA <25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
DCK
321 mW
2.6 mW/°C
206 mW
167 mW
recommended operating conditions
MIN
Supply voltage, VDD
Input voltage, VI
Operating free-air temperature range, TA
MAX
6
V
0
VDD+0.3
85
°C
–40
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
UNIT
1.3
V
5
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VOH
TEST CONDITIONS
VDD = 1.5 V,
VDD = 3.3 V,
High-level
High
level out
output
ut voltage (TPS3805 only)
VDD = 6 V,
VDD = 1.5 V,
VOL
VDD = 3.3 V,
VDD = 6 V,
VIT > 1.5 V, TA = 25°C
Low-level
Low
level out
output
ut voltage
Power up reset voltage (see Note 2)
Power-up
IOH = –1.0 mA
IOH = –1.5 mA
IOL = 1.0 mA
N
ti
i iinputt th
h ld
Negative-going
threshold
voltage (see Note 3)
VIT ≤ 1.5 V, TA = 25°C
TPS3803G15
0.8xVDD
II
IOH
Input current
SENSE
High-level output current at RESET
Open drain only
0.8
TA = –40°C
40 C to 85
85°C
C
Supply current
1.226
1.244
1.379
1.4
1.421
3.004
3.05
3.096
V
15
mV
30
VDD=VIT+0.2V, VOH=VDD
VDD=3.3 V, output unconnected
TPS3803–01
TPS3805,
TPS3803G15
CI
V
1.208
TPS3803–01
IDD
V
V
–25
TPS3805,
TPS3803G15
UNIT
V
0.3
1.2 V < VIT < 2.5 V
2.5 V < VIT < 3.5 V
Hysteresis
MAX
1.0
TPS3805H33
Vhys
TYP
IOL = 2 mA
IOL = 3 mA
SENSE
VIT
MIN
IOH = –0.5 mA
VDD=6 V, output unconnected
25
nA
300
nA
2
4
3
5
2
4
4
6
µA
A
Input capacitance
VI= 0 V to VDD
1
pF
NOTES: 2. The lowest supply voltage at which RESET (VOL(max) = 0.2 V, IOL = 50 µA) becomes active. tr(VDD) ≥ 15 µs/V
3. To ensure the best stability of the threshold voltage, place a bypass capacitor (ceramic, 0.1 µF) near the supply terminals.
timing requirements at RL = 1 MΩ, CL = 50 pF, TA = –40°C to 85°C
PARAMETER
tw
TEST CONDITIONS
At VDD
Pulse width
At SENSE
VIH = 1.05
1 05 x VIT, VIL = 0.95
0 95 x VIT
MIN
TYP
MAX
UNIT
µss
55
5.5
switching characteristics at RL = 1 MΩ, CL = 50 pF, TA = –40°C to 85°C
PARAMETER
TEST CONDITIONS
tPHL
Pro agation (delay) time,
Propagation
high-to-low-level output
VDD to RESET delay
SENSE to RESET delay
tPLH
Pro agation (delay) time,
Propagation
low-to-high-level output
VDD to RESET delay
SENSE to RESET delay
6
POST OFFICE BOX 655303
VIH = 1.05 x VIT,
VIL = 0.95
0 95 x VIT
• DALLAS, TEXAS 75265
MIN
TYP
MAX
5
100
5
100
UNIT
µss
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
TYPICAL CHARACTERISTICS
TPS3805H33
SUPPLY CURRENT
vs
SUPPLY VOLTAGE
TPS3803–01
SUPPLY CURRENT
vs
SUPPLY VOLTAGE
6
3
SENSE = GND
RESET = Open
2.5
I DD – Supply Current – µ A
I DD – Supply Current – µ A
5
4
3
85°C
2
25°C
0°C
–40°C
1
2
1.5
85°C
25°C
1
0°C
–40°C
0.5
0
0
0.5
1
1.5
2 2.5
3 3.5
4
4.5 5
5.5
SENSE = GND
RESET = Open
0
6
0
1.5
2 2.5
3 3.5
4
4.5 5
Figure 1
Figure 2
5.5
6
LOW-LEVEL OUTPUT VOLTAGE
vs
LOW-LEVEL OUTPUT CURRENT
1.60
0.50
VDD = 1.5 V
V(SENSE) = Low
1.40
1.20
85°C
1.00
25°C
0.80
0°C
0.60
–40°C
0.40
0.20
(Expanded View)
VDD = 1.5 V
V(SENSE) = Low
0.45
VOL – Low-Level Output Voltage – V
VOL – Low-Level Output Voltage – V
1
VDD – Supply Voltage – V
LOW-LEVEL OUTPUT VOLTAGE
vs
LOW-LEVEL OUTPUT CURRENT
0
0.5
VDD – Supply Voltage – V
0.40
85°C
0.35
25°C
0.30
0°C
0.25
–40°C
0.20
0.15
0.10
0.05
0
1
2
3
4
5
0
0
0.5
1
1.5
2
2.5
IOL – Low-Level Output Current – mA
IOL – Low-Level Output Current – mA
Figure 3
Figure 4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
7
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
TYPICAL CHARACTERISTICS
LOW-LEVEL OUTPUT VOLTAGE
vs
LOW-LEVEL OUTPUT CURRENT
LOW-LEVEL OUTPUT VOLTAGE
vs
LOW-LEVEL OUTPUT CURRENT
1
VDD = 6 V
V(SENSE) = Low
3
85°C
2.5
25°C
2
0°C
–40°C
1.5
1
0.5
0
VDD = 6 V
V(SENSE) = Low
0.9
VOL – Low-Level Output Voltage – V
VOL – Low-Level Output Voltage – V
3.5
85°C
0.8
25°C
0.7
0°C
0.6
–40°C
0.5
0.4
0.3
0.2
(Expanded View)
0.1
0
0
5
10
15
20
25
30
35
40
45
50
0
10
14
12
16
Figure 6
18
20
TPS3805H33
HIGH-LEVEL OUTPUT VOLTAGE
vs
HIGH-LEVEL OUTPUT CURRENT
3.3
VDD = 3.3 V
V(SENSE) = High
VOH – High-Level Output Voltage – V
VOH – High-Level Output Voltage – V
8
Figure 5
3
2.75
85°C
2.5
25°C
2.25
0°C
2
–40°C
1.75
–12
–10
–8
–6
–4
–2
0
IOH – High-Level Output Current – mA
3.2
VDD = 3.3 V
V(SENSE) = High
3.1
3
85°C
2.9
25°C
0°C
2.8
–40°C
2.7
2.6
(Expanded View)
2.5
–5
–4
–3
–2
Figure 8
POST OFFICE BOX 655303
–1
IOH – High-Level Output Current – mA
Figure 7
8
6
IOL – Low-Level Output Current – mA
3.5
1.5
–14
4
IOL – Low-Level Output Current – mA
TPS3805H33
HIGH-LEVEL OUTPUT VOLTAGE
vs
HIGH-LEVEL OUTPUT CURRENT
3.25
2
• DALLAS, TEXAS 75265
0
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
TYPICAL CHARACTERISTICS
TPS3805H33
HIGH-LEVEL OUTPUT VOLTAGE
vs
HIGH-LEVEL OUTPUT CURRENT
TPS3805H33
HIGH-LEVEL OUTPUT VOLTAGE
vs
HIGH-LEVEL OUTPUT CURRENT
6
VDD = 6 V
V(SENSE) = High
VOH – High-Level Output Voltage – V
VOH – High-Level Output Voltage – V
6
5.5
5
85°C
4.5
25°C
4
0°C
3.5
–40°C
3
–4
–3
–2
5.6
5.4
85°C
25°C
5.2
0°C
–40°C
5
(Expanded View)
4.8
4.6
–14
0
–1
VDD = 6 V
V(SENSE) = High
5.8
IOH – High-Level Output Current – mA
–12
–8
–6
–4
–2
0
Figure 10
TPS3803–01
NORMALIZED INPUT THRESHOLD VOLTAGE
vs
FREE-AIR TEMPERATURE AT SENSE
MINIMUM PULSE DURATION AT VDD
vs
VDD THRESHOLD OVERDRIVE VOLTAGE
10
1.0020
VDD = 6 V
RESET = 100 kΩ to VDD
1.0015
tw – Minimum Pulse Duration at VDD – µs
VIT – Normalized Input Threshold Voltage VIT(TA) / VIT(25°C)
Figure 9
1.0010
1.0005
1.0000
0.9995
0.9990
0.9985
0.9980
–40
–10
IOH – High-Level Output Current – mA
–20
0
20
40
60
80
TA – Free-Air Temperature at SENSE – °C
9
8
7
6
5
4
3
2
1
0
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
1
VDD – Threshold Overdrive Voltage – V
Figure 11
Figure 12
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
TYPICAL CHARACTERISTICS
MINIMUM PULSE DURATION AT SENSE
vs
SENSE THRESHOLD OVERDRIVE VOLTAGE
tw – Minimum Pulse Duration at SENSE – µs
10
9
8
7
6
5
4
3
2
1
0
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
SENSE – Threshold Overdrive Voltage – V
Figure 13
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
TPS3803-01, TPS3803G15, TPS3805H33
VOLTAGE DETECTOR
SLVS392 – JULY 2001
MECHANICAL DATA
DCK (R-PDSO-G5)
PLASTIC SMALL-OUTLINE
0,30
0,15
0,65
5
0,10 M
4
1,40
1,10
1
0,13 NOM
2,30
1,90
3
Gage Plane
2,15
1,85
0,15
0°–8°
0,46
0,26
Seating Plane
1,10
0,80
0,10
0,00
0,10
4093553/B 06/99
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion.
Falls within JEDEC MO-203
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its products to the specifications applicable at the time of sale in accordance with
TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary
to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except
those mandated by government requirements.
Customers are responsible for their applications using TI components.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
products or services might be or are used. TI’s publication of information regarding any third party’s products
or services does not constitute TI’s approval, license, warranty or endorsement thereof.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations and notices. Representation
or reproduction of this information with alteration voids all warranties provided for an associated TI product or
service, is an unfair and deceptive business practice, and TI is not responsible nor liable for any such use.
Resale of TI’s products or services with statements different from or beyond the parameters stated by TI for
that product or service voids all express and any implied warranties for the associated TI product or service,
is an unfair and deceptive business practice, and TI is not responsible nor liable for any such use.
Also see: Standard Terms and Conditions of Sale for Semiconductor Products. www.ti.com/sc/docs/stdterms.htm
Mailing Address:
Texas Instruments
Post Office Box 655303
Dallas, Texas 75265
Copyright  2001, Texas Instruments Incorporated