INTEGRATED CIRCUITS P83C557E6/P80C557E6 Single-chip 8-bit microcontroller Product specification 1999 Mar 02 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 1. FEATURES • 80C51 central processing unit • 48 K × 8 ROM, expandable externally to 64 Kbytes • ROM Code protection • 1536 × 8 RAM, expandable externally to 64 Kbytes • Two standard 16-bit timer/counters • An additional 16-bit timer/counter coupled to four capture registers and three compare registers 2. GENERAL DESCRIPTION • A 10-bit ADC with eight multiplexed analog inputs and The P80C557E6/P83C557E6 (hereafter generically referred to as P8xC557E6) single-chip 8-bit microcontroller is manufactured in an advanced CMOS process and is a derivative of the 80C51 microcontroller family. The P8xC557E6 has the same instruction set as the 80C51. Three versions of the derivative exist: programmable autoscan • Two 8-bit resolution, pulse width modulation outputs • Five 8-bit I/O ports plus one 8-bit input port shared with analog • P83C557E6 — 48 Kbytes mask programmable ROM • P80C557E6 — ROMless version of the P83C557E6 inputs • I2C-bus serial I/O port with byte oriented master and slave functions The P8xC557E6 contains a non-volatile 48 Kbytes mask programmable ROM (P83C557E6), a volatile 1536 × 8 read/write data memory, five 8-bit I/O ports, one 8-bit input port, two 16-bit timer/event counters (identical to the timers of the 80C51), an additional 16-bit timer coupled to capture and compare latches, a 15-source, two-priority-level, nested interrupt structure, an 8-input ADC, a dual DAC pulse width modulated interface, two serial interfaces (UART and I2C-bus), a “watchdog” timer, an on-chip oscillator and timing circuits. For systems that require extra capability the P8xC557E6 can be expanded using standard TTL compatible memories and logic. • Full-duplex UART compatible with the standard 80C51 • On-chip watchdog timer • 15 interrupt sources with 2 priority levels (2 to 6 external sources possible) • Extended temperature range (–40 to +85 °C) • 4.5 to 5.5 V supply voltage range • Frequency range for 80C51–family standard oscillator: 3.5 MHz to 16 MHz In addition, the P8xC557E6 has two software selectable modes of power reduction — Idle Mode and power-down mode. The Idle Mode freezes the CPU while allowing the RAM, timers, serial ports, and interrupt system to continue functioning. The power-down mode saves the RAM contents but freezes the oscillator, causing all other chip functions to be inoperative. • PLL oscillator with 32 kHz reference and software–selectable system clock frequency • Seconds Timer • Software enable/disable of ALE output pulse • Electromagnetic compatibility improvements • Wake–up from Power–down by external or seconds interrupt 1999 Mar 02 The device also functions as an arithmetic processor having facilities for both binary and BCD arithmetic as well as bit-handling capabilities. The instruction set consists of over 100 instructions: 49 one-byte, 45 two-byte, and 17 three- byte. With a 16 MHz system clock, 58% of the instructions are executed in 0.75 µs and 40% in 1.5 µs. Multiply and divide instructions require 3 µs. 2 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 3. ORDERING INFORMATION PACKAGE FREQUENCY RANGE (MHz) EXTENDED TYPE NUMBER NAME DESCRIPTION CODE TEMPERATURE RANGE (°C) ROMless P80C557E6EBB QFP80 Plastic Quad Flat Pack; 80 leads SOT318-1 3.5 to 16 0 to +70 P80C557E6EFB QFP80 Plastic Quad Flat Pack; 80 leads SOT318-1 3.5 to 16 –40 to +85 P83C557E6EBB/YYY1 QFP80 Plastic Quad Flat Pack; 80 leads SOT318-1 3.5 to 16 0 to +70 P83C557E6EFB/YYY1 QFP80 Plastic Quad Flat Pack; 80 leads SOT318-1 3.5 to 16 –40 to +85 ROM coded NOTE: 1. YYY denotes the ROM code number. T0 T1 3 INT0 3 INT1 3 PWM0 PWM1 AV SS VDD 3 VSS ADC0-7 SDA AVREF + – AVDD ADEXS SCL 5 SELXTAL1 6 RSTIN XTAL1 XTAL2 T0, T1 TWO 16-BIT TIMER/EVENT COUNTERS DATA MEMORY 256 x 8 RAM + 1280 x 8 RAM PROGRAM MEMORY 48 K x 8 ROM CPU DUAL PWM I2C SERIAL I/O ADC EA 80C51 CORE EXCLUDING ROM/RAM ALE PSEN 3 WR 3 8-BIT INTERNAL BUS RD 0 AD0-7 PARALLEL I/O PORTS AND EXTERNAL BUS 2 SERIAL UART PORT 8-BIT PORTS A8-15 3 P0 P1 P2 P3 TxD FOUR 16-BIT CAPTURE LATCHES 3 RxD 1 P5 P4 CT0I-CT3I ALTERNATE FUNCTION OF PORT0 3 ALTERNATE FUNCTION OF PORT 3 1 ALTERNATE FUNCTION OF PORT1 4 ALTERNATE FUNCTION OF PORT 4 2 ALTERNATE FUNCTION OF PORT2 5 ALTERNATE FUNCTION OF PORT 5 0 T2 16-BIT TIMER/ EVENT COUNTERS 16 1 16 3 COMPARATOR OUTPUT SELECTION 1 T2 6 RT2 T3 WATCH– DOG TIMER PLL oscillator + ”seconds” timer 4 EW XTAL3 XTAL4 CMSR0-CMSR5 RSTOUT CMT0, CMT1 NOT PRESENT IN P80C557E6 Figure 1. Block diagram P8xC557E6. 1999 Mar 02 T2 16-BIT COMPARATORS WITH REGISTERS Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 XTAL3 XTAL4 VSS VDD SELXTAL1 XTAL2 EA 0 0 1 1 2 ALE/WE LOW ORDER ADDRESS AND 4 DATA BUS 5 5 AD0–7 6 6 7 7 4 AVSS AVDD AVref+ AVref– CT0I/INT2 1 CT1I/INT3 PWM1 2 CT2I/INT4 SCL 3 SDA 4 PWM0 PORT 5 2 3 P8xC557E6 1 CT3I/INT5 T2 RT2 5 0 ADC0-7 PORT 1 0 ADEXS 6 7 0 1 5 2 6 3 7 4 0 5 1 6 2 7 0 RxD/DATA 3 4 1 TxD/CLOCK 5 2 CMT0 6 3 CMT1 7 EW PORT 3 PORT 4 RSTIN RSTOUT PORT 2 4 CMSR0-5 4 HIGH ORDER ADDRESS BUS A8–15 INT0 INT1 4 T0 5 T1 6 WR 7 RD Figure 2. Functional diagram. 1999 Mar 02 2 3 3 PSEN PORT 0 XTAL1 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 AVref– AVref+ n.c. SELXTAL1 XTAL4 XTAL3 AVSS2 AVDD2 P0.0/AD0 P0.1/AD1 P0.2/AD2 P0.3/AD3 P0.4/AD4 P0.5/AD5 P0.6/AD6 P0.7/AD7 V SS4 V DD4 EA 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 4. PINNING 1 64 ALE/WE 2 63 PSEN AVSS 3 62 P2.7/A15 1 AVDD1 4 61 P2.6/A14 P5.7/ADC7 5 60 P2.5/A13 P5.6/ADC6 6 59 P2.4/A12 P5.5/ADC5 7 58 P2.3/A11 P5.4/ADC4 8 57 P2.2/A10 P5.3/ADC3 9 56 P2.1/A9 P5.2/ADC2 10 55 P2.0/A8 P5.1/ADC1 11 54 VSS3 P5.0/ADC0 12 53 VDD3 VSS1 13 52 XTAL1 VDD1 14 51 XTAL2 ADEXS 15 50 n.c. PWM0 16 49 n.c. PWM1 17 48 P3.7/RD EW 18 47 P3.6/WR P4.0/CMSR0 19 46 P3.5/T1 P4.1/CMSR1 20 45 P3.4/T0 P4.2/CMSR2 21 44 P3.3/INT1 P4.3/CMSR3 22 43 P3.2/INT0 RSTOUT 23 42 P3.1/TXD P4.4/CSMR4 24 41 P3.0/RXD 35 36 37 38 39 40 P1.4/T2 P1.5/RT2 P1.6 P1.7 SCL SDA P1.3/CT3I/INT5 34 31 P1.0/CT0I/INT2 P1.2/CT2I/INT4 33 30 RSTIN P1.1/CT1I/INT3 32 29 V SS2 27 P4.7/CMT1 28 26 P4.6/CMT0 V DD2 25 P4.5/CMSR5 P8xC557E6 = not connected Figure 3. Pinning diagram for QFP80 (SOT318). 1999 Mar 02 5 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 4.1 PIN DESCRIPTIONS SYMBOL PIN DESCRIPTION AVref– AVref+ 1 2 Low end of analog to digital conversion reference resistor High end of analog to digital conversion reference resistor. AVSS1 AVDD1 3 4 Analog ground for ADC Analog power supply (+5 V) for ADC AVSS2 AVDD2 77 76 Analog ground; for PLL oscillator Analog power supply; (+5 V) for PLL oscillator P5.7 – P5.0 5 – 12 Port 5 8–bit input port Port pin Alternative function P5.0–P5.7 Eight input channels to ADC (ADC0–ADC7) VDD1, VDD2, VDD3, VDD4 14, 28, 53, 66 Digital power supply: +5 V power supply pins during normal operation and power reduction modes. All pins must be connected. VSS1, VSS2 VSS3, VSS4 13, 29, 54, 67 Digital ground: circuit ground potential. All pins must be connected. ADEXS 15 Start ADC operation: Input starting analog to digital conversion triggered by a programmable edge (ADC operation can also be started by software). This pin must not float PWM0 16 Pulse width modulation output 0 PWM1 17 Pulse width modulation output 1 EW 18 Enable watchdog timer: Enable for T3 watchdog timer and disable Power–down Mode.This pin must not float. P4.0 – P4.7 19 – 22 24 – 27 Port 4 8–bit quasi–bidirectional I/O port Port pin Alternative function P4.0 P4.1 P4.2 P4.3 P4.4 P4.5 P4.6 P4.7 CMSR0 } CMSR1 } CMSR2 } CMSR3 } CMSR4 } CMSR5 } CMT0 } CMT1 } compare and set/reset outputs on a match with timer T2 compare and toggle outputs on a match with timer T2 RSTIN 30 Reset: Input to reset the P8xC557E6. RSTOUT 23 Reset: Output of the P8xC557E6 for resetting peripheral devices during initialization and Watchdog Timer overflow. P1.0 – P1.7 31 – 38 Port 1 8–bit quasi–bidirectional I/O port Port pin Alternative function P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 CT0I/INT2} CT1I/INT3} : CT2I/INT4} CT3I/INT5} T2 : RT2 : Capture timer inputs for timer T2 or external interrupt inputs T2 event input, rising edge triggered T2 timer reset input, rising edge triggered SCL 39 I2C–bus serial clock I/O port SDA 40 I2C–bus serial data I/O port If SCL and SDA are not used, they must be connected to VSS. 1999 Mar 02 6 Philips Semiconductors Product specification Single-chip 8-bit microcontroller SYMBOL PIN P83C557E6/P80C557E6 DESCRIPTION P3.0 – P3.7 41 – 48 8–bit quasi–bidirectional I/O port Port pin Alternative function P3.0 RXD : Serial input port P3.1 TXD : Serial output port : External interrupt P3.2 INT0 P3.3 INT1 : External interrupt P3.4 T0 : Timer 0 external input P3.5 T1 : Timer 1 external input : External data memory write strobe P3.6 WR P3.7 RD : External data memory read strobe N.C. 49 – 50 Not connected pins. XTAL2 51 Crystal pin 2: output of the inverting amplifier that forms the oscillator. Left open–circuit when an external oscillator clock is used. XTAL1 52 Crystal pin 1: input to the inverting amplifier that forms the oscillator, and input to the internal clock generator. Receives the external oscillator clock signal when an external oscillator is used. Must be connected to logic HIGH if the PLL oscillator is selected (SELXTAL1 = LOW) P2.0 – P2.7 55 – 62 Port2: 8–bit quasi–bidirectional I/O port with internal pull–ups.During access to external memories (RAM/ROM) that use 16–bit addresses (MOVX@DPTR) Port 2 emits the high order address byte. Port 2 can sink/source one TTL (=4 LSTTL) input. It can drive CMOS inputs without external pull–ups. PSEN 63 Program Store Enable output: read strobe to the external program memory via Port 0 and 2. Is activated twice each machine cycle during fetches from external program memory. When executing out of external program memory two activations of PSEN are skipped during each access to external data memory. PSEN is not activated (remains HIGH) during no fetches from external program memory. PSEN can sink/source 8 LSTTL inputs. It can drive CMOS inputs without external pull–ups. ALE/WE 64 Address Latch Enable output: latches the low byte of the address during access of external memory in normal operation. It is activated every six oscillator periods except during an external data memory access. ALE/WE can sink/–source 8 LSTTL inputs. It can drive CMOS inputs without an external pull–up. To prohibit the toggling of ALE pin (RFI noise reduction) the bit RFI in the PCON Register (PCON.5) must be set by software. This bit is cleared on RESET and can be set and cleared by software. When set, ALE pin will be pulled down internally, switching an external address latch to a quiet state. The MOVX instruction will still toggle ALE if external memory is accessed. ALE will retain its normal high value during Idle Mode and a low value during Power–down Mode while in the “RFI” mode. Additionally during internal access (EA = 1) ALE will toggle normally when the address exceeds the internal program memory size. During external access (EA = 0) ALE will always toggle normally, whether the flag “RFI” is set or not. EA 65 External Access Input: If, during RESET, EA is held at a TTL level HIGH the CPU executes out of the internal program memory, provided the program counter is less than 49152. If, during RESET, EA is held at a TTL level LOW the CPU executes out of external program memory via Port 0 and Port 2. EA is not allowed to float. EA is latched during RESET and don’t care after RESET. P0.7–P0.0 68 –75 Port 0: 8–bit open drain bidirectional I/O port. It is also the multiplexed low–order address and data bus during accesses to external memory (during theses accesses internal pull–ups are activated). Port 0 can sink/source 8 LSTTL inputs. XTAL3 78 Crystal pin, output of the inverting amplifier that forms the 32 kHz oscillator XTAL4 79 Crystal pin, input to the inverting amplifier that forms the 32 kHz oscillator. XTAL3 and XTAL4 are pulled LOW if the PLL oscillator is not selected (SELXTAL1 = HIGH) or if Reset is active. SELXTAL1 80 Must be connected to logic HIGH level to select the HF oscillator, using the XTAL1/XTAL2 crystal. If pulled low the PLL is selected for clocking of the controller, using the XTAL3/ XTAL4 crystal. NOTE: 1. To avoid a ‘latch–up’ effect at Power–on, the voltage at any pin at any time must not be higher or lower than VDD+ 0.5 V or VSS– 0.5 V respectively. 1999 Mar 02 7 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 5. ELECTROMAGNETICS COMPATIBILITY (EMC) IMPROVEMENTS 6. FUNCTIONAL DESCRIPTION 6.1 General Primary attention was paid on the reduction of electromagnetic emission of the microcontroller P8xC557E6. The P8xC557E6 is a stand–alone high–performance microcontroller designed for use in real time applications such as instrumentation, industrial control, medium to high–end consumer applications and specific automotive control applications. The following features effect in reducing the electromag– netic emission and additionally improve the electromagnetic susceptibility: • Four supply voltage pins (VDD) and four ground pins (VSS) with In addition to the 80C51 standard functions, the device provides a number of dedicated hardware functions for these applications. pairs of VDD and VSS at two adjacent pins at each side of the package. The P8xC557E6 is a control–oriented CPU with on–chip program and data memory. It can be extended with external program memory up to 64 Kbytes. It can also access up to 64 Kbytes of external data memory. For systems requiring extra capability, the P8xC557E6 can be expanded using standard memories and peripherals. • Separated VDD pins for the internal logic and the port buffers • Internal decoupling capacitance improves the EMC radiation behavior and the EMC immunity • External capacitors are to be located as close as possible The P8xC557E6 has two software selectable modes of reduced activity for further power reduction – Idle and Power–down. The Idle Mode freezes the CPU while allowing the RAM, timers, serial ports and interrupt system to continue functioning. The Power–down Mode saves the RAM contents but freezes the oscillator causing all other chip functions to be inoperative.The Power–down Mode can be terminated by an external Reset, by the seconds interrupt and by any one of the two external interrupts. (see description Wake–up from Power–down Mode). between pins VDD1 and VSS1, VDD2 and VSS2, VDD3 and VSS3 as well as VDD4 and VSS4 ; ceramic chip capacitors are recommended (100nF). • The ALE output signal (pulses at a frequency off CLK/6) can be disabled under software control (bit 5 in the SFR PCON: “RFI”); if disabled, no ALE pulse will occur. ALE pin will be pulled down internally, switching an external address latch to a quiet state. The MOVX instruction will still toggle ALE (external data memory is accessed). ALE will retain its normal HIGH value during Idle Mode and a LOW value during Power-down mode while in the “RFI” reduction mode. Additionally during internal access (EA = 1) ALE will toggle normally when the address exceeds the internal program memory size. During external access (EA = 0) ALE will always toggle normally, whether the flag “RFI” is set or not. 64 K 64 K External 49152 Overlapped Space 49151 49151 1280 255 Internal (EA = 1) External (EA = 0) Special Function Registers INDIRECT ONLY (ARD = 1) (ARD = 0) 1280 bytes 127 DIRECT AND INDIRECT 0 0 AUXILIARY RAM 0 0 Program Memory Internal Data Memory Figure 4. Memory map & address space. 1999 Mar 02 8 External Data Memory Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 – RAM 0 to 127 can be addressed directly and indirectly as in the 80C51. Address pointers are R0 and R1 of the selected registerbank. – RAM 128 to 255 can only be addressed indirectly. Address pointers are R0 and R1 of the selected registerbank. – AUX–RAM 0 to 1279 is also indirectly addressable as external DATA MEMORY locations 0 to 1279 via MOVX–Datapointer instruction, unless it is disabled by setting ARD = 1. AUX–RAM 0 to 1279 is indirectly addressable via pageregister (XRAMP) and MOVX–Ri instructions, unless it is disabled by setting ARD = 1 (see Figure 5). When executing from internal program memory, an access to AUX–RAM 0 to 1279 will not affect the ports P0, P2, P3.6 and P3.7. An access to external DATA MEMORY locations higher than 1279 will be performed with the MOVX @ DPTR instructions in the same way as in the 80C51 structure, so with P0 and P2 as data/address bus and P3.6 and P3.7 as write and read timing signals. Note that the external DATA MEMORY cannot be accessed with R0 and R1 as address pointer if the AUX–RAM is enabled (ARD = 0, default). – The Special Function Registers (SFR) can only be addressed directly in the address range from 128 to 255 (see Table 5). – Four register banks, each 8 registers wide, occupy locations 0 through 31 in the lower RAM area. Only one of these banks may be enabled at a time. The next 16 bytes, locations 32 through 47, contain 128 directly addressable bit locations.The stack can be located anywhere in the internal 256 bytes RAM.The stack depth is only limited by the available internal RAM space of 256 bytes (see Figure 7). All registers except the program counter and the four register banks reside in the Special Function Register address space. 6.2 Memory Organization The central processing unit (CPU) manipulates operands in three memory spaces; these are the 64 Kbytes external data memory, 1536 bytes internal data memory (consisting of 256 bytes standard RAM and 1280 bytes AUX–RAM) and the 48 Kbytes internal and/or 64 Kbytes external program memory (see Figure 4). 6.2.1 Program Memory The program memory of the P8xC557E6 consists of 48 Kbytes ROM on–chip, externally expandable up to 64 Kbytes. If, during RESET, the EA pin was held HIGH, the P8xC557E6 executes out of the internal program memory unless the address exceeds 0BFFFH. Locations 0C000H through 0FFFFH are then fetched from the external program memory. If the EA pin was held LOW during RESET the P8xC557E6 fetches all instructions from the external program memory. The EA input is latched during RESET and is don’t care after RESET. The internal program memory content is protected, by setting a mask programmable security bit (ROM), i.e., it cannot be read out at any time by any test mode or by any instruction in the external program memory space. The MOVC instructions are the only ones which have access to program code in the internal or external program memory. The EA input is latched during RESET and is ‘don’t care’ after RESET. This implementation prevents from reading internal program code by switching from external program memory to internal program memory during MOVC instruction or an instruction that handles immediate data. Table 1 lists the access to the internal and external program memory with MOVC instructions when the security feature has been activated. 6.2.2 Internal Data Memory The internal data memory is divided into three physically separated parts: 256 bytes of RAM, 1280 bytes of AUX–RAM, and a 128 bytes special function area. These can be addressed each in a different way (see also Table 2). Table 1. Memory access by the MOVC instruction for protected ROMs MOVC LOCATION ACCESS TO INTERNAL PROGRAM MEMORY ACCESS TO EXTERNAL PROGRAM MEMORY MOVC in internal program memory YES YES MOVC in external program memory NO YES NOTE: 1. If the security feature has not been activated, there are no restrictions for MOVC instructions. Table 2. Internal data memory map LOCATION ADDRESSED RAM 0 to 127 Direct and indirect AUX–RAM 0 to 1279 Indirect only with MOVX RAM 128 to 255 Indirect only SFR 128 to 255 Direct only 1999 Mar 02 9 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 255 1279 (XRAMP) = 04 H 0 255 1024 1023 (XRAMP) = 03 H MOVX @Ri, A MOVX A, @Ri 768 767 0 255 (XRAMP) = 02 H 512 511 0 255 MOVX @DPTR,A MOVX A,@DPTR (XRAMP) = 01 H 0 255 256 255 (XRAMP) = 00 H 0 0 Figure 5. Indirect addressing of AUX–RAM (1280 Bytes), ARD bit in PCON = 0. 1999 Mar 02 10 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 6.2.2.1 AUX–RAM Page Register XRAMP The AUX–RAM Page Register is used to select one of five 256 bytes pages of the internal 1280 bytes AUX–RAM for MOVX–accesses via R0 or R1. Its reset value is (XXXXX000). XRAMP (FAH) 7 6 5 4 3 2 1 0 x x x x x XRAMP2 XRAMP1 XRAMP0 x: undefined during read, a write operation must write “0” to these locations Figure 6. AUX–RAM page register. Table 3. Description of XRAMP bits BIT XRAMP.3–7 XRAMP.2 XRAMP.1 XRAMP.0 SYMBOL XRAMPx XRAMP2 XRAMP1 XRAMP0 FUNCTION reserved for future use AUX–RAM page select bit 2 AUX–RAM page select bit 1 AUX–RAM page select bit 0 Table 4. Memory locations for all possible MOVX–accesses ARD1 XRAMP2 XRAMP1 XRAMP0 0 0 0 0 AUX–RAM locations 0 0 0 1 AUX–RAM locations 256 .. 511 0 0 1 0 AUX–RAM locations 512 .. 767 0 0 1 1 AUX–RAM locations 768 ... 1023 0 1 0 0 AUX–RAM locations 1024 .. 1279 0 1 0 1 no valid memory access; reserved for future use 0 1 1 X no valid memory access; reserved for future use 1 X X X External RAM locations MOVX @Ri,A and MOVX A,@Ri instructions access: 0 .. 255 (reset condition) 0 .. 255 MOVX @DPTR,A and MOVX A,@DPTR instructions access: 0 X X X AUX–RAM locations 0 .. 1279 (reset condition) External RAM locations 1280 .. 65535 1 X X X External RAM locations NOTE: 1. ARD (AUX–RAM Disable) is a bit in the Special Function Register PCON 1999 Mar 02 11 0 .. 65535 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Table 5. Special Function Register Memory Map and Reset Values High Nibble of SFR Address LOW 8 9 A B C D E F 0 P0 % 11111111 P1 % 11111111 P2 % 11111111 P3 % 11111111 P4 % 11111111 PSW % 00000000 ACC % 00000000 B% 00000000 1 SP 00000111 2 DPL 00000000 3 DPH 00000000 ADRSL1 # XXXXXXXX ADRSL2 # XXXXXXXX ADRSL3 # XXXXXXXX ADRSL4 # XXXXXXXX ADRSL5 # XXXXXXXX ADRSL6 # XXXXXXXX ADRSL7 # XXXXXXXX P5 # XXXXXXXX ADCON 00000000 ADPSS 00000000 ADRSH # 000000XX TM2IR % 00000000 S1CON % 00000000 IEN1 % 00000000 IP1 % 00000000 4 5 % # X 6 ADRSL0 # XXXXXXXX 7 PCON 00000000 8 TCON % 00000000 S0CON % 00000000 IEN0 % 00000000 9 TMOD 00000000 S0BUF XXXXXXXX CML0 00000000 CMH0 00000000 S1STA # 11111000 A TL0 00000000 CML1 00000000 CMH1 00000000 S1DAT 00000000 TM2CON 00000000 B TL1 00000000 CML2 00000000 CMH2 00000000 S1ADR 00000000 CTCON 00000000 C TH0 00000000 CTL0 # XXXXXXXX CTH0 # XXXXXXXX TML2 # 00000000 PWM0 00000000 D TH1 00000000 CTL1 # XXXXXXXX CTH1 # XXXXXXXX TMH2 # 00000000 PWM1 00000000 E CTL2 # XXXXXXXX CTH2 # XXXXXXXX STE 11000000 PWMP 00000000 F CTL3 # XXXXXXXX CTH3 # XXXXXXXX RTE 00000000 T3 00000000 = = = IP0 % X0000000 XRAMP XXXXX000 Bit addressable register Read only register Undefined • Register in one of the four register banks through Register, Direct 6.3 Addressing The P8xC557E6 has five methods for addressing: or Register–Indirect addressing • Register • Direct • Register–Indirect • Immediate • Base–Register plus Index–Register–Indirect • 1536 bytes of internal RAM through Direct or Register–Indirect addressing. Bytes 0–127 of internal RAM may be addressed directly/indirectly. Bytes 128–255 of internal RAM share their address location with the SFRs and so may only be addressed indirectly as data RAM. Bytes 0–1279 of AUX–RAM can only be addressed indirectly via MOVX. • Special Function Register through direct addressing at address locations 128–255 (see Figure 8). The first three methods can be used for addressing destination operands. Most instructions have a “destination/source” field that specifies the data type, addressing methods and operands involved. For operations other than MOVs, the destination operand is also a source operand. • External data memory through Register–Indirect addressing • Program memory look–up tables through Base– Register plus Index–Register–Indirect addressing Access to memory addresses is as follows: 1999 Mar 02 PLLCON 00001101 12 Philips Semiconductors Product specification Single-chip 8-bit microcontroller BYTE ADDRESS (HEX) FFH 2FH P83C557E6/P80C557E6 BYTE ADDRESS (DECIMAL) BIT ADDRESS (HEX) (MSB) 7F (LSB) 7E 7D 7C 7B 255 7A 79 78 47 2EH 77 76 75 74 73 72 71 70 46 2DH 6F 6E 6D 6C 6B 6A 69 68 45 2CH 67 66 65 64 63 62 61 60 44 2BH 5F 5E 5D 5C 5B 5A 59 58 43 2AH 57 56 55 54 53 52 51 50 42 29H 4F 4E 4D 4C 4B 4A 49 48 41 28H 47 46 45 44 43 42 41 40 40 27H 3F 3E 3D 3C 3B 3A 39 38 39 26H 37 36 35 34 33 32 31 30 38 25H 2F 2E 2D 2C 2B 2A 29 28 37 24H 27 26 25 24 23 22 21 20 36 23H 1F 1E 1D 1C 1B 1A 19 18 35 22H 17 16 15 14 13 12 11 10 34 21H 0F 0E 0D 0C 0B 0A 09 08 33 20H 07 06 05 04 03 02 01 00 32 1FH 31 Bank 3 18H 24 17H 23 Bank 2 10H 16 0FH 15 Bank 1 08H 8 07H 7 Bank 0 0 00H Figure 7. RAM bit addresses. 1999 Mar 02 13 Philips Semiconductors Product specification Single-chip 8-bit microcontroller DIRECT BYTE ADDRESS (HEX) P83C557E6/P80C557E6 REGISTER MNEMONIC BIT ADDRESS (HEX) FFH (MSB) (LSB) PT2 PCM2 PCM1 PCM0 PCT3 PCT2 PCT1 PCT0 F8H FF FE FD FC FB FA F9 F8 IP1 F0H F7 F6 F5 F4 F3 F2 F1 F0 B ET2 ECM2 ECM1 ECM0 ECT3 ECT2 ECT1 ECT0 E8H EF EE ED EC EB EA E9 E8 IEN1 E0H E7 E6 E5 E4 E3 E2 E1 E0 ACC CR2 ENS1 STA STO SI AA CR1 CR0 DF DE DD DC DB DA D9 D8 CY AC F0 RS1 RS0 OV F1 P D7 D6 D5 D4 D3 D2 D1 D0 D8H D0H PSW T2OV CMI2 CMI1 CMI0 CTI3 CTI2 CTI1 CTI0 C8H CF CE CD CC CB CA C9 C8 TM2IR C0H C7 C6 C5 C4 C3 C2 C1 C0 P4 – PAD PS1 PS0 PT1 PX1 PT0 PX0 B8H BF BE BD BC BB BA B9 B8 IP0 B0H B7 B6 B5 B4 B3 B2 B1 B0 P3 EA EAD ES1 ES0 ET1 EX1 ET0 EX0 A8H AF AE AD AC AB AA A9 A8 IEN0 A0H A7 A6 A5 A4 A3 A2 A1 A0 P2 SM0 SM1 SM2 REN TB8 RB8 TI RI 9F 9E 9D 9C 9B 9A 99 98 S0CON P1 98H 90H 97 96 95 94 93 92 91 90 TF1 TR1 TF0 TR0 IE1 IT1 IE0 IT0 88H 8F 8E 8D 8C 8B 8A 89 88 TCON 80H 87 86 85 84 83 82 81 80 P0 Figure 8. Special Function Register bit addresses. 1999 Mar 02 S1CON 14 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 6.4 I/O Facilities Port 4 : The P8xC557E6 has six 8–bit ports. Ports 0 to 3 are the same as in the 80C51, with the exception of the additional functions of Port 1. The parallel I/O function of Port 4 is equal to that of Ports 1, 2 and 3. Port 5 has a parallel input port function, but has no function as an output port. can be configured to provide signals indicating a match between timer counter T2 and its compare registers. Port 5 : may be used in conjunction with the ADC interface.Unused analog inputs can be used as digital inputs. As Port 5 lines may be used as inputs to the ADC, these digital inputs have an inherent hysteresis to prevent the input logic from drawing too much current from the power lines when driven by analog signals. Channel to channel crosstalk should be taken into consideration when both digital and analog signals are simultaneously input to Port 5 (see DC characteristics). The SDA and SCL lines serve the serial port SI01 (I2C). Because the I2C–bus may be active while the device is disconnected from VDD, these pins, are provided with open drain drivers. Ports 0, 1, 2, 3, 4 and 5 perform the following alternative functions: Port 0 : provides the multiplexed low–order address and data bus used for expanding the P8xC557E6 with standard memories and peripherals. Port 1 : All ports are bidirectional with the exception of Port 5 which is an input port. Port 1 is used for a number of special functions: Pins of which the alternative function is not used may be used as normal bidirectional I/Os. 4 capture inputs (or external interrupt request inputs if capture information is not utilized) – external counter input – external counter reset input Port 2 : provides the high–order address bus when the P8xC557E6 is expanded with external Program Memory and/or external Data Memory. Port 3 : pins can be configured individually to provide: – external interrupt request inputs – counter inputs – receiver input and transmitter output of seri port SIO 0 (UART) – control signals to read and write external Data Memory The generation or use of a Port 1, Port 3 or Port 4 pin as an alternative function is carried out automatically by the P8xC557E6 provided the associated Special Function Register bit is set HIGH. The pull–up arrangements of Ports 1 – 4 are shown in Figure 9. VDD VDD VDD P1 P2 P3 2 System Clock Periods Port Pin n QN From Port Latch Input Data Read Port Pin P1 is turned on for 2 system clock periods after QN makes a 1–to–0 transition. During this time, P1 also turns on P3 through the inverter to form an additional pull up. Figure 9. I/O buffers in the P8xC557E6 (Ports 1, 2, 3 and 4). 1999 Mar 02 15 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 this application, the PWM outputs must be integrated using conventional operational amplifier circuitry. If the resulting output voltages have to be accurate, external buffers with their own analog supply should be used to buffer the PWM outputs before they are integrated. The repetition frequency fpwm, at the PWMn outputs is give by: f CLK f PWM 2 (1 PWMP) 255 6.5 Pulse Width Modulated Outputs The P8xC557E6 contains two pulse width modulated output channels (see Figure 13). These channels generate pulses of programmable length and interval. The repetition frequency is defined by an 8-bit prescaler PWMP, which supplies the clock for the counter. The prescaler and counter are common to both PWM channels. The 8-bit counter counts module 255, i.e., from 0 to 254 inclusive. The value of the 8-bit counter is compared to the contents of two registers: PWM0 and PWM1. Provided the contents of either of these registers is greater than the counter value, the corresponding PWM0 or PWM1 output is set LOW. If the contents of these registers are equal to, or less than the counter value, the output will be HIGH. The pulse-width-ratio is therefore defined by the contents of the registers PWM0 and PWM1. The pulse-width-ratio is in the range of 0/255 to 255/255 and may be programmed in increments of 1/255. This gives a repetition frequency range of 123 Hz to 31.4 kHz (fCLK = 16 MHz). By loading the PWM registers with either 00H or FFH, the PWM channels will output a constant HIGH or LOW level, respectively. Since the 8-bit counter counts modulo 255, it can never actually reach the value of the PWM registers when they are loaded with FFH. When a compare register (PWM0 or PWM1) is loaded with a new value, the associated output is updated immediately. It does not have to wait until the end of the current counter period. Both PWMn output pins are driven by push-pull drivers. These pins are not used for any other purpose. Buffered PWM outputs may be used to drive DC motors. The rotation speed of the motor would be proportional to the contents of PWMn. The PWM outputs may also be configured as a dual DAC. In 7 PWMP (FEH) PWMP.7 6 5 PWMP.6 PWMP.5 4 PWMP.4 3 2 PWMP.3 PWMP.2 1 PWMP.1 0 PWMP.0 Figure 10. Prescaler frequency control register PWMP. Table 6. Description of PWMP bits BIT FUNCTION PWMP.0 to 7 Prescaler division factor = (PWMP) + 1 Reading PWMP gives the current reload value. The actual count of the prescaler cannot be read. 7 PWM0 (FCH) PWM0.7 6 5 PWM0.6 PWM0.5 4 PWM0.4 3 2 PWM0.3 PWM0.2 Figure 11. Pulse width register PWM0. Table 7. Description of PWM0 bits BIT PWM0.0 to 7 1999 Mar 02 FUNCTION LOW/HIGH ration of PWM0 signal = 16 (PWM0) 255 – (PWM0) 1 PWM0.1 0 PWM0.0 Philips Semiconductors Product specification Single-chip 8-bit microcontroller 7 PWM1 (FDH) PWM1.7 6 P83C557E6/P80C557E6 5 PWM1.6 PWM1.5 4 PWM1.4 3 2 1 PWM1.3 PWM1.2 PWM1.1 0 PWM1.0 Figure 12. Pulse width register PWM1. Table 8. Description of PWM1 bits BIT FUNCTION LOW/HIGH ration of PWM1 signal = PWM1.0 to 7 (PWM1) 255 – (PWM1) PWM0 8-Bit Comparator Output Buffer PWM0 Output Buffer PWM1 Internal Bus fCLK 1/2 Prescaler 8-Bit Counter PWMP 8-Bit Comparator PWM1 Figure 13. Functional Diagram of Pulse Width Modulated Outputs. 1999 Mar 02 17 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 • Start of a conversion by software or with an external signal. • Eight 10–bit buffer registers, one register for each analog input 6.6 Analog/Digital Converter (ADC) The P8xC557E6 A/D Converter is a 10–bit, successive approximation ADC with 8 multiplexed analog input channels. It additionally contains a high input impedance comparator, a DAC built with 1024 series resistors and analog switches, registers and control logic. channel. • Interrupt request after one channel scan loop. • Programmable prescaler (dividing by 2, 4, 6, 8) to adapt to Input voltage range is from AVref– (typical 0V) to AVref+ (typical +5V). A set of 8 buffer registers (10–bit) store the conversion results of the proper analog input channel each. different system clock frequencies. • Conversion time for one A/D conversion: 15 µs ... 50 µs • Differential non–linearity : DLe ±1 LSB. • Integral non–linearity : ILe ±2 LSB. • Offset error : OSe ±2LSB. • Gain error : Ge ±0.4 %. • Absolute voltage error : Ae ±3 LSB. • Channel to channel matching : Mctc ±1LSB. • Crosstalk between analog inputs : Ct < –60dB. @100 kHz. • Monotonic and no missing codes. • Separated analog (AVDD, AVSS) and digital (VDD, VSS) supply 11 Special Function Registers (SFR) perform the user software interface to the ADC: a control SFR (ADCON), an analog port scan–select SFR (ADPSS), 8 input channel related conversion result SFR with the 8 lower result bits (ADRSL0...ADRSL7), one common result SFR for the upper 2 result bits (ADRSH). An extra SFR (P5) allows for reading digital input port data as an alternative function of the 8 analog input pins. In order to have a minimum of ADC service overhead in the microcontroller program, the ADC is able to operate autonomously within its user configurable autoscan function. The functional diagram of the ADC is shown in Figure 14. Feature Overview: • 10–bit resolution. • 8 multiplexed analog inputs. • Programmable autoscan of the analog inputs. • Bit oriented 8–bit scan–select register to select analog inputs. • Continuous scan or one time scan configurable from 1 to 8 analog voltages. • Reference voltage at two special pins : AVREF– and AVREF+. For further information on the ADC characteristics, refer to the “DC CHARACTERISTICS” section. inputs. ADC0 COMPARATOR ANALOG + Mux. SAR – ADC7 10 AVref+ 10 DAC AVref– 10 AVDD1 8x 10–bit result registers AVSS1 ADEXS 2 8 SCAN LOGIC 2 LATCHES ADPSS 8 ADCON Read ADRS H 8 Read ADRSLn 2 INTERNAL BUS Figure 14. Functional diagram of AD converter. 1999 Mar 02 18 8 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 6.6.1 Functional Description Table 9. A/D Special Function Registers SYMBOL NAME ACCESS ADCON A/D control register read/write ADPSS Analog port scan–select register read/write ADRSLn 8 A/D result registers, the 8 lower bits (n: 0...7) read only ADRSH A/D result register, the 2 higher bits read only P5 Digital input port (shared with analog inputs) read only A/D Control Register ADCON The Special Function Register ADCON contains control and status bits for the A/D Converter peripheral block. The reset value of ADCON is (00000000). Its hardware address is D7H. ADCON is not bit addressable. 7 ADCON (D7H) 6 ADPR1 ADPR0 5 ADPOS 4 3 2 ADINT ADSST ADCSA 1 ADSRE 0 ADSFE Figure 15. ADC control register. Table 10. Description of ADCON bits SYMBOL BIT FUNCTION ADCON.7 ADCON.6 ADPR1 ADPR0 Control bit for the prescaler. Control bit for the prescaler. ADPR1=0 ADPR0=0 Prescaler divides by 2 (default by reset) ADPR1=0 ADPR0=1 Prescaler divides by 4 ADPR1=1 ADPR0=0 Prescaler divides by 6 ADPR1=1 ADPR0=1 Prescaler divides by 8 ADCON.5 ADPOS ADPOS is reserved for future use. Must be ‘0’ if ADCON is written. ADCON.4 ADINT ADC interrupt flag. This flag is set when all selected analog inputs are converted, as well in continuous scan as in one–time scan mode. An interrupt is invoked if this interrupt is enabled. ADINT must be cleared by software. It cannot be set by software. ADCON.3 ADSST ADC start and status. Setting this bit by software or by hardware (via ADEXS input) starts the A/D conversion of the selected analog inputs. ADSST stays a ‘one’ in continuous scan mode. In one–time scan mode, ADSST is cleared by hardware when the last selected analog input channel has been converted. As long as ADSST is ‘1’, new start commands to the ADC–block are ignored. An A/D conversion in progress is aborted if ADSST is cleared by software. ADCON.2 ADCSA 1 0 = = Continuous scan of the selected analog inputs after a start of an A/D conversion. One–time scan of the selected analog inputs after a start of an A/D conversion. ADCON.1 ADSRE 1 0 = = A rising edge at input ADEXS will start the A/D conversion and generate a capture signal. A rising edge at input ADEXS has no effect. ADCON.0 ADSFE 1 0 = = A falling edge at input ADEXS will start the A/D conversion and generate a capture signal. A falling edge at input ADEXS has no effect. 1999 Mar 02 19 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 A/D Input Port Scan-Select Register ADPSS The Special Function Register ADPSS contains control bits to select the analog input channel(s) to be scanned for A/D conversion. The reset value of ADPSS is (00000000). Its hardware address is E7H. ADPSS is not bit addressable. Reading Special Function Register P5 does not affect A/D conversions. But it is recommended to use the digital input port function of the hardware Port 5 only as an alternative to analog input voltage conversions. Simultaneous mixed operation is discouraged for the sake of A/D conversion result reliability and accuracy. If all bits are ‘0’ then no A/D conversion can be started. If ADPSS is written while an A/D conversion is in progress (ADSST in the ADCON register is ‘1’) then the autoscan loop with the previous selected analog inputs is completed first. The next autoscan loop is performed with the new selected analog inputs. For further information on Port 5, refer to the “I/O facilities” section. For further information on A/D Special Function Registers, refer to the “Internal Data Memory” section. Reset After a RESET of the microcontroller the ADCON and ADPSS register bits are initialized to zero. Registers ADRSLn and ADRSH are not initialized by a RESET. A/D Result Registers ADRSLn and ADRSH: The binary result code of A/D conversions is accessed by these Special Function Registers. The result SFR are read only registers. The read value after reset is indeterminate. Their data are not affected by chip reset. They are not bit addressable. Idle and Power-down Mode The A/D Converter is active only when the microcontroller is in normal operating mode. If the Idle or Power-down Mode is activated, then the ADC is switched off and put into a power saving idle state a conversion in progress is aborted, a previously set ADSST flag is cleared and the internal clock is halted. The conversion result registers are not affected. There are 8 Special Function Registers ADRSLn (ADRSL0...ADRSL7) – A/D Result Low byte - and one general SFR ADRSH - A/D Result High byte - . Each of ADRSLn is associated with the coincidently indexed analog input channel ADCn (ADC0/P5.0...ADC7/P5.7). Reading an ADRSLn register by software copies at the same time the two highest bits of the 10-bit conversion result into two latches, thus preserving them until the next read of any ADRSLn register. These two latches form bit positions 0 and 1 of SFR ADRSH, the upper 6 bits of ADRSH are always read as ‘0’. The interrupt flag ADINT will not be set by activation of Idle or Power-down Mode. A previously set flag ADINT will not be cleared by the hardware. (Note: ADINT cannot be cleared by hardware at all, except for a RESET - it must be cleared by the user software.) After a wakeup from Idle or Power-down Mode a set flag ADINT indicates that at least one autoscan loop was finished completely before the microcontroller was put into the respective power reduction mode and it indicates that the stored result data may be fetched now - if desired. Thus it is ensured to get the 10-bit result of the same single A/D conversion by reading any register ADRSLn first and after it the register ADRSH. Digital Input Port Register P5 Port 5 Special Function Register P5 always represents the binary value of the logic level at input pins P5.0/ADC0...P5.7/ADC7. P5 is not affected by chip reset. P5 is a read only register. Its hardware address is C7H. P5 is not bit addressable. 7 ADPSS (E7H) ADPSS7 For further information on Idle and Power-down Mode, refer to the “Power reduction modes” section. 6 5 4 3 2 1 0 ADPSS6 ADPSS5 ADPSS4 ADPSS3 ADPSS2 ADPSS1 ADPSS0 ADPSS7–0 For each individual bit position: 0 1 = The corresponding analog input is skipped in the auto-scan loop. = The corresponding analog input is included in the auto-scan loop. Figure 16. A/D input port scan-select register. 7 ADRSLn ADRSn.7 6 5 ADRSn.6 ADRSn.5 4 ADRSn.4 3 2 ADRSn.3 ADRSn.2 1 ADRSn.1 0 ADRSn.0 (n: 0...7) ADRSH 7 6 5 4 3 2 1 0 0 0 0 0 0 ADRSn.9 ADRSn.8 3 2 1 0 P5.3 P5.2 Figure 17. 7 P5 (C7H) P5.7 6 A/D Result Registers. 5 P5.6 P5.5 4 P5.4 Figure 18. Digital input port register P5. 1999 Mar 02 0 20 P5.1 P5.0 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 is selected according to the next higher set bit position in ADPSS, converted and stored, and so on. When the result of the last conversion of this autoscan loop is stored, flag ADCON.4/ADINT, the ADC interrupt flag, is set. It is not cleared by interrupt hardware – it must be cleared by software. Timing A programmable prescaler is controlled by the bits ADPR1 and ADPR0 in register ADCON to adapt the conversion time for different microcontroller clock frequencies. Table 11 shows conversion times (tconv) for one A/D conversion at some convenient system clock frequencies (fclk) and ADC prescaler divisors (m), which are user selectable by the bits ADCON.7/ADPR1 and ADCON.6/ADPR0. In continuous scan mode (ADCON.2/ADCSA=1) the ADC start and status flag ADCON.3/ADSST retains the set state and the autoscan loop restarts from the beginning. In one–time scan mode (ADCSA=0) conversions stop after the last selected analog input was converted, ADINT is set and ADSST is cleared automatically. For conversion times outside the limits for tconv the specified ADC characteristics are not guaranteed; (prohibited conversion times are put in brackets): ADSST cannot be set (neither externally nor by software) as long as ADINT=1, i.e. as long as ADINT is set, a new conversion start – by setting flag ADSST – is inhibited; actually it is only delayed until ADINT is cleared. Table 11. Conversion time configuration examples (tconv/µs) (If a ‘1’ is written to ADSST while ADINT=1, this new value is internally latched and preserved, not setting ADSST until ADCON.4/ADINT=0. In this state, a read of SFR ADCON will display ADCON.3/ADSST=0, because always the effective ADC status is read.) fCLK m 6 MHz 8 MHz 12 MHz 16 MHz 2 4 6 8 26 50 [74] [98] 19.5 37.5 [55.5] [73.5] [13] 25 37 49 [9.75] 18.75 27.75 36.75 Note that under software control the analog inputs can also be converted in arbitrary order, when one–time scan mode is selected and in SFR ADPSS only one bit is set at a time. In this case ADINT is set and ADSST is cleared after every conversion. Conversion time tconv = (6 m + 1) machine cycles A conversion time tconv consists of one sample time period (which equals two bit conversion times), 10 bit conversion time periods and one machine cycle to store the result. 6.6.3 Resolution and Characteristics The ADC system has its own analog supply pins AVDD and AVSS. It is referenced by two special reference voltage input pins sourcing the resistance ladder of the DAC: AVref+ and AVref–. The voltage between AVREF+ and AVREF– defines the full–scale range. Due to the 10–bit resolution the full scale range is divided into 1024 unit steps. The unit step voltage is 1 LSB, which is typically 5 mV (AVref+ = 5.12 V, AVref– = 0 V = AVSS). After result storage an extra initializing time period follows to select the next analog input channel (according to the contents of SFR ADPSS), before the input signal is sampled. Thus the time period between two adjacent conversions within an autoscan loop is larger than the pure time tconv. This autoscan cycle time is (7 m) machine cycles. The DAC’s resistance ladder has 1023 equally spaced taps, separated by a unit resistance ‘R’. The first tap is located 0.5 x R above AVref–, the last tap is located 1.5 x R below AVref+. This results in a total ladder resistance of 1024 x R. This structure ensures that the DAC is monotonic and results in a symmetrical quantization error. For input voltages between AVref– and (AVref– + 1/2 LSB) the 10–bit conversion result code will be 00 0000 0000 B = 000H = 0D. For input voltages between (AVref+ – 3/2 LSB) and AVref+ the 10–bit conversion result code will be 11 1111 1111 B = 3FFH = 1023D. At the start of an autoscan conversion the time between writing to SFR ADCON and the first analog input signal sampling depends on the current prescaler value (m) and the relative time offset between this write operation and the internal (divided) ADC clock. This gives a variation range for the A/D conversion start time of ( m / 2 ) machine cycles. 6.6.2 Configuration and Operation Every A/D conversion is an autoscan conversion. The two user selectable general operation modes are continuous scan and one–time scan mode. The result code corresponding to an analog input voltage (AVin) can be calculated from the formula: The desired analog input port channel/s for conversion is/are selected by programming A/D input port scan–select bits in SFR ADPSS. An analog input channel is included in the autoscan loop if the corresponding bit in ADPSS is 1, a channel is skipped if the corresponding bit in ADPSS is 0. + The analog input voltage should be stable when it is sampled for conversion. At any times the input voltage slew rate must be less than 10 V/ms (5 V conversion range) in order to prevent an undefined result. An autoscan is always started according to the lowest bit position of ADPSS that contains a 1. An autoscan conversion is started by setting the flag ADSST in register ADCON either by software or by an external start signal at input pin ADEXS, if enabled. Either no edge (external start totally disabled), a rising edge or/and a falling edge of ADEXS is selectable for external conversion start by the bits ADSRE and ADSFE in register ADCON. This maximum input voltage slew rate can be ensured by an RC low pass filter with R = 2k2 and C = 100 nF. The capacitor between analog input pin and analog ground pin shall be placed close to the pins in order to have maximum effect in minimizing input noise coupling. After completion of an A/D conversion the 10–bit result is stored in the corresponding 10–bit buffer register. Then the next analog input 1999 Mar 02 * * ) * * 21 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 • Mode 1: • Mode 2: 6.7 Timer / Counters The P8xC557E6 contains three 16-bit timer/event counters: Timer 0, Timer 1 and Timer T2 and one 8-bit timer, T3. Timer 0 and Timer 1 may be programmed to carry out the following functions: 8-bit time-interval or event counter with automatic reload upon overflow • Mode 3: • Measure time intervals and pulse durations • Count events • Generate interrupt requests With a 16 MHz crystal, the counting frequency of these timer/counters is as follows: In the timer function, the register is incremented every machine cycle. Thus, one can think of it as counting machine cycles. Since a machine cycle consists of 12 oscillator periods, the count rate is 1/12 of the oscillator frequency. • In the timer function, the timer is incremented at a frequency of 1.33 MHz - a division by 12 of the system clock frequency • 0 Hz to an upper limit of 0.66 MHz (1/24 of the system clock In the counter function, the register is incremented in response to a 1-to-0 transition at the corresponding external input pin, T0 or T1. In this function, the external input is sampled during S5P2 of every machine cycle. When the samples show a HIGH in one cycle and a LOW in the next cycle, the counter is incremented. Thus, it takes two machine cycles (24 oscillator periods) to recognize a 1-to-0 transition. There are no restrictions on the duty cycle of the external input signal, but to insure that a given level is sampled at least once before it changes, it should be held for at least one full machine cycle. frequency) when programmed for external inputs Both internal and external inputs can be gated to the counter by a second external source for directly measuring pulse durations. When configured as a counter, the register is incremented on every falling edge on the corresponding input pin, T0 or T1. The incremented register value can be read earliest during the second machine cycle after that one, during which the incrementing pulse occurred. The counters are started and stopped under software control. Each one sets its interrupt request flag when it overflows from all HIGHs to all LOWs (or automatic reload value), with the exception of mode 3 as previously described. Timer 0 and Timer 1 can be programmed independently to operate in one of four modes: 8-bit timer or 8-bit counter each with divide-by-32 prescaler 7 TMOD (89H) GATE 6 5 C/T M1 -Timer 0: one 8-bit time-interval or event counter and one 8-bit time-interval counter -Timer 1: stopped When Timer 0 is in Mode 3, Timer 1 can be programmed to operate in Modes 0, 1 or 2 but cannot set an interrupt request flag or generate an interrupt. However the overflow from Timer 1 can be used to pulse the serial port baud-rate generator. 6.7.1 Timer 0 and Timer 1 Timers 0 and 1 each have a control bit in SFR TMOD that selects the timer or counter function of the corresponding timer. • Mode 0: 16-bit time-interval or event counter 4 3 2 1 M0 GATE C/T M1 0 M0 Timer 0 Timer 1 Figure 19. Timer/Counter mode control (TMOD) register. Table 12. Description of TMOD bits SYMBOL BIT FUNCTION Gate TMOD.7 TMOD.3 Gating control when set. Timer/Counter “x” is enabled only while “INTx” pin is high and “TRx” control pin is set. When cleared Timer “x” is enabled whenever “TRx” control bit is set. C/T TMOD.6 TMOD.2 Timer or Counter Selector cleared for Timer operation (input from internal system clock). Set for Counter operation (input from “Tx” input pin). M1 TMOD.5 TMOD.1 TMOD.4 TMOD.0 Timer 0, Timer 1 mode select see Table 13. M0 Table 13. Timer 0 / Timer 1 operation select M1 M0 0 0 8048 Timer “TLx” serves as 5-bit prescaler. 0 1 16-bit Timer/Counter “THx” and “TLx” are cascaded; there is no prescaler. 1 0 8-bit auto-reload Timer/Counter “THx” holds a value which is to be reloaded into “TLx” each time it overflows. 1 1 (Timer 0) TL0 is an 8-bit Timer/Counter controlled by the standard Timer 0 control bits. TH0 is an 8-bit timer only controlled by Timer 1 control bits. 1 1 (Timer 1) Timer/Counter 1 stopped. 1999 Mar 02 OPERATING 22 Philips Semiconductors Product specification Single-chip 8-bit microcontroller 7 TCON (88H) TF1 P83C557E6/P80C557E6 6 5 4 TR1 TF0 TR0 3 2 IE1 IT1 1 0 IE0 IT0 Figure 20. Timer/Counter mode control (TCON) register. Table 14. Description of TCON bits SYMBOL BIT FUNCTION TF1 TCON.7 Timer 1 overflow flag. Set by hardware on Timer/Counter overflow. Cleared by hardware when processor vectors to interrupt routine. TR1 TCON.6 Timer 1 run control bit. Set/cleared by software to turn Timer/Counter on/off. TF0 TCON.5 Timer 0 overflow flag. Set by hardware on Timer/Counter overflow. Cleared by hardware when processor vectors to interrupt routine. TR0 TCON.4 Timer 0 run control bit. Set/cleared by software to turn Timer/Counter on/off. IE1 TCON.3 Interrupt 1 edge flag. Set by hardware when external interrupt edge detected. Cleared when interrupt processed. IT1 TCON.2 Interrupt 1 type control bit. Set/cleared by software to specify falling edge/low level triggered external interrupts. IE0 TCON.1 Interrupt 0 edge flag. Set by hardware when external interrupt edge detected. Cleared when interrupt processed. IT0 TCON.0 Interrupt 0 type control bit. Set/cleared by software to specify falling edge/low level triggered external interrupts. 1999 Mar 02 23 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 byte while T2 is being read. T2 is not loadable and is reset by the RST signal or at the positive edge of the input signal RT2, if enabled. In the Idle or Power-down Mode the timer/counter and prescaler are reset and halted. 6.7.2 Timer T2 Timer T2 is a 16 bit timer/counter which has capture and compare facilities. The operational diagram is shown in Figure 21. The 16 bit timer/counter is clocked via a prescaler with a programmable division factor of 1, 2, 4 or 8. The input of the prescaler is clocked with 1/12 of the clock frequency, or by an external source connected to the T2 input, or it is switched off. The maximum repetition rate of the external clock source is fCLK/12, twice that of Timer 0 and Timer 1. The prescaler is incremented on a rising edge. It is cleared if its division factor or its input source is changed, or if the timer/counter is reset (see also Figure 22: TM2CON). T2 is readable ‘on the fly’, without any extra read latches; this means that software precautions have to be taken against misinterpretation at overflow from least to most significant CT0I CT1I INT T2 is connected to four 16-bit Capture Registers: CT0, CT1, CT2 and CT3. A rising or falling edge on the inputs CT0I, CT1I, CT2I or CT3I (alternative function of Port 1) results in loading the contents of T2 into the respective Capture Registers and an interrupt request. Using the Capture Register CTCON (see Figure 23), these inputs may invoke capture and interrupt request on a positive, a negative edge or on both edges. If neither a positive nor a negative edge is selected for capture input, no capture or interrupt request can be generated by this input. CT2I INT CTI0 CTI1 CT0 CT3I INT INT CTI2 CT1 CTI3 CT2 CT3 off 8-bit overflow interrupt fCLK Prescaler 1/12 T2 Counter 16-bit overflow interrupt T2 RT2 T2ER External reset enable COMP S R P4.0 S R P4.1 S R P4.2 S R P4.3 S R P4.4 S R P4.5 TG T P4.6 TG T P4.7 STE RTE CMO (S) COMP CM1 (R) INT COMP CM2 (T) I/O port 4 S = set R = reset T = toggle TG = toggle status Figure 21. Block diagram of Timer 2. 1999 Mar 02 INT 24 T2 SFR address: TML2 = lower 8 bits TMH2 = higher 8 bits INT Philips Semiconductors Product specification Single-chip 8-bit microcontroller 7 TM2CON (EAH) T2IS1 P83C557E6/P80C557E6 6 T2IS0 5 T2ER 4 3 2 T2BO T2P1 T2P0 1 T2MS1 0 T2MS0 Figure 22. T2 control register (TM2CON). Table 15. Description of TM2CON bits SYMBOL BIT FUNCTION T2IS1 TM2CON.7 Timer T2 16-bit overflow interrupt select T2IS0 TM2CON.6 Timer T2 byte overflow interrupt select T2ER TM2CON.5 Timer T2 external reset enable. When this bit is set, Timer T2 may be reset by a rising edge on RT2 (P1.5). T2BO TM2CON.4 Timer T2 byte overflow interrupt flag T2P1 TM2CON.3 Timer T2 prescaler select T2P0 TM2CON.2 T2MS1 TM2CON.1 T2MS0 TM2CON.0 Timer T2 mode select Table 16. Timer 2 prescaler select T2P1 T2P0 TIMER T2 CLOCK 0 0 Clock source 0 1 Clock source/2 1 0 Clock source/4 1 1 Clock source/8 Table 17. Timer 2 mode select T2MS1 T2MS0 0 0 Timer T2 halted (off) MODE SELECTED 0 1 T2 clock source = fCLK/12 1 0 Test mode; do not use 1 1 T2 clock source = pin T2 7 CTCON (EBH) CTN3 6 CTP3 5 CTN2 4 3 2 1 0 CTP2 CTN1 CTP1 CTN0 CTP0 Figure 23. Capture control register (CTCON). Table 18. Description of CTCON bits SYMBOL BIT CTN3 CTCON.7 Capture Register 3 triggered by a falling edge on CT3I CTP3 CTCON.6 Capture Register 3 triggered by a rising edge on CT3I CTN2 CTCON.5 Capture Register 2 triggered by a falling edge on CT2I CTP2 CTCON.4 Capture Register 2 triggered by a rising edge on CT2I CTN1 CTCON.3 Capture Register 1 triggered by a falling edge on CT1I CTP1 CTCON.2 Capture Register 1 triggered by a rising edge on CT1I CTN0 CTCON.1 Capture Register 0 triggered by a falling edge on CT0I CTP0 CTCON.0 Capture Register 0 triggered by a rising edge on CT0I 1999 Mar 02 FUNCTION 25 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 match toggles bits 6 and 7 of Port 4, provided these functions are enabled by the STE respectively RTE registers. A match of CM0 and CM1 at the same time results in resetting bits 0–5 of Port 4. CM0, CM1 and CM2 are reset by the RSTIN signal. The contents of the Compare Registers CM0, CM1 and CM2 are continuously compared with the counter value of Timer T2. When a match occurs, an interrupt may be invoked. A match of CM0 sets the bits 0–5 of Port 4, a CM1 match resets these bits and a CM2 7 TM2IR (C8H) T2OV 6 5 4 3 2 1 0 CMI2 CMI1 CMI0 CTI3 CTI2 CTI1 CTI0 Figure 24. Interrupt flag register (TM2IR). Table 19. Description of TM2IR bits SYMBOL BIT FUNCTION T2OV TM2IR.7 Timer T2 16-bit overflow interrupt flag CMI2 TM2IR.6 CM2 interrupt flag CMI1 TM2IR.5 CM1 interrupt flag CMI0 TM2IR.4 CM0 interrupt flag CTI3 TM2IR.3 CT3 interrupt flag CTI2 TM2IR.2 CT2 interrupt flag CTI1 TM2IR.1 CT1 interrupt flag CTI0 TM2IR.0 CT0 interrupt flag 7 STE (EEH) TG47 6 5 4 3 2 1 0 TG46 SP45 SP44 SP43 SP42 SP41 SP40 Figure 25. Set enable register (STE). Table 20. Description of STE bits SYMBOL BIT TG47 STE.7 If “1” then P4.7 is reset on the next toggle, if LOW P4.7 is set on the next toggle TG46 STE.6 If “1” then P4.6 is reset on the next toggle, if LOW P4.6 is set on the next toggle SP45 STE.5 If “1” then P4.5 is set on a match between CM0 and Timer T2 SP44 STE.4 If “1” then P4.4 is set on a match between CM0 and Timer T2 SP43 STE.3 If “1” then P4.3 is set on a match between CM0 and Timer T2 SP42 STE.2 If “1” then P4.2 is set on a match between CM0 and Timer T2 SP41 STE.1 If “1” then P4.1 is set on a match between CM0 and Timer T2 SP40 STE.0 If “1” then P4.0 is set on a match between CM0 and Timer T2 1999 Mar 02 FUNCTION 26 Philips Semiconductors Product specification Single-chip 8-bit microcontroller 7 RTE (EFH) 6 TP47 TP46 P83C557E6/P80C557E6 5 RP45 4 3 2 1 0 RP44 RP43 RP42 RP41 RP40 Figure 26. Reset/Toggle enable register (RTE). Table 21. Description of RTE bits SYMBOL BIT FUNCTION TP47 RTE.7 If “1” then P4.7 toggles on a match between CM2 and Timer T2 TP46 RTE.6 If “1” then P4.6 toggles on a match between CM2 and Timer T2 RP45 RTE.5 If “1” then P4.5 toggles on a match between CM1 and Timer T2 RP44 RTE.4 If “1” then P4.4 toggles on a match between CM1 and Timer T2 RP43 RTE.3 If “1” then P4.3 toggles on a match between CM1 and Timer T2 RP42 RTE.2 If “1” then P4.2 toggles on a match between CM1 and Timer T2 RP41 RTE.1 If “1” then P4.1 toggles on a match between CM1 and Timer T2 RP40 RTE.0 If “1” then P4.0 toggles on a match between CM1 and Timer T2 For more information concerning the TM2CON, CTCON, TM2IR and the STE/RTE registers see IC20 handbook, chapter “80C51 family hardware description”. Port 4 can be read and written by software without affecting the toggle, set and reset signals. At a byte overflow of the least significant byte, or at a 16-bit overflow of the timer/counter, an interrupt sharing the same interrupt vector is requested. Either one or both of these overflows can be programmed to request an interrupt. All interrupt flags must be reset by software. Internal Bus Prescaler (11-bit) fCLK/12 Clear Timer T3 (8-bit) to reset circuitry (see Figure 46) LOAD LOADEN Write T3 Clear WLE PCON.4 EW Internal Bus Figure 27. Watchdog timer. 1999 Mar 02 27 PD LOADEN PCON.1 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 second byte is complete, one of the bytes will be lost. The SIO0 receive and transmit registers are both accessed via the S0BUF special function register. Writing to S0BUF loads the transmit register, and reading S0BUF accesses to a physically separate receive register. SIO0 can operate in 4 modes: 6.8 Watchdog Timer T3 In addition to Timer T2 and the standard timers, a watchdog timer (T3) consisting of an 11–bit prescaler and an 8–bit timer is also incorporated (see Figure 27). The timer is incremented every 1.5 ms, derived from the system clock frequency of 16 MHz by the following: Mode 0: Serial data is transmitted and received through RXD. TXD outputs the shift clock. 8 data bits are transmitted/received (LSB first). The baud rate is fixed at 1/12 of the oscillator frequency. A write into S0CON should be avoided during a transmission to avoid spikes on RXD/TXD. When a timer overflow occurs, the microcontroller is reset and a reset output pulse is generated at pin RSTOUT. Also the PLL control register is reset. Mode 1: 10 bits are transmitted via TXD or received through RXD: a start bit (0), 8 data bits (LSB first), and a stop bit(1). On receive, the stop bit is put into RB8 (S0CON special function register). The baud rate is variable. To prevent a system reset the timer must be reloaded in time by the application software. If the processor suffers a hardware/software malfunction, the software will fail to reload the timer. This failure will produce a reset upon overflow thus preventing the processor running out of control. Mode 2: 11 bits are transmitted through TXD or received through RXD: a start bit (0), 8 data bits (LSB first), a programmable 9th data bit, and a stop bit (1). On transmit, the 9th data bit (TB8 in S0CON) can be assigned the value of 0 or 1. With nominal software, TB8 can be the parity bit (P in PSW). During a receive, the 9th data bit is stored in RB8 (S0CON), and the stop bit is ignored. The baud rate is programmable to either 1/32 or 1/64 of the oscillator frequency. The watchdog timer can only be reloaded if the condition flag WLE = PCON.4 has been previously set by software. At the moment the counter is loaded the condition flag is automatically cleared. The time interval between the timer’s reloading and the occurrence of a reset depends on the reloaded value. For example, this may range from 1.5 ms to 0.375 s when using an oscillator frequency of 16 MHz. Mode 3: 11 bits are transmitted through TXD or received through RXD: a start bit (0), 8 data bits (LSB first), a programmable 9th data bit, and a stop bit (1). Mode 3 is the same as Mode 2 except the baud rate which is variable in Mode 3. In the Idle state the watchdog timer and reset circuitry remain active. The watchdog timer is controlled by the watchdog enable pin (EW). A LOW level enables the watchdog timer and disables the Power–down Mode. A HIGH level disables the watchdog timer and enables the Power–down Mode. In all four modes, transmission is initiated by any instruction that writes to the S0BUF function register. Reception is initiated in Mode 0 when RI = 0 and REN = 1. In the other three modes, reception is initiated by the incoming start bit provided that REN = 1. 6.9 Serial I/O Modes 2 and 3 are provided for multiprocessor communications. In these modes, 9 data bits are received with the 9th bit written to RB8. The 9th bit is followed by the stop bit. The port can be programmed so that with receiving the stop bit, the serial port interrupt will be activated if, and only if RB8 = 1. The P8xC557E6 is equipped with two independent serial ports: SIO0 and SI01. SIO0 is the full duplex UART port, identical to the PCB80C51 serial port. SIO1 is an I2C–bus serial I/O interface with byte oriented master and slave functions. 6.9.1 SIO0 (UART) SIO 0 is a full duplex serial I/O port – it can transmit and receive simultaneously. This serial port is also receive–buffered. It can commence reception of a second byte before the previously received byte has been read from the receive register. If, however, the first byte has still not been read by the time reception of the 1999 Mar 02 This feature is enabled by setting bit SM2 in S0CON. This feature may be used in multiprocessor systems. For more information about how to use the UART in combination with the registers S0CON, PCON, IEN0, S0BUF and Timer register refer to the 80C51 Data Handbook IC20. 28 Philips Semiconductors Product specification Single-chip 8-bit microcontroller 7 S0CON (98H) SM0 6 P83C557E6/P80C557E6 5 SM1 SM2 4 3 2 1 0 REN TB8 RB8 TI RI Figure 28. Serial port control (S0CON) register. Table 22. Description of S0CON bits SYMBOL BIT SM0 S0CON.7 This bit is used to select the serial port mode. See Table 23 FUNCTION SM1 S0CON.6 This bit is used to select the serial port mode. See Table 23 SM2 S0CON.5 Enables the multiprocessor communication feature in modes 2 and 3. In mode 2 or 3, if SM2 is set to 1, then RI will not be activated if the received 9th data bit (RB8) is 0. In mode 1, if SM2 = 1, then RI will not be activated if a valid stop bit was not received. In mode 0, SM2 should be 0. REN S0CON.4 Enables serial reception. Set by software to enable reception. Clear by software to disable reception. TB8 S0CON.3 The 9th data bit that will be transmitted in modes 2 and 3. Set or clear by software as desired. RB8 S0CON.2 In modes 2 and 3, RB8 is the 9th data bit that was received. In mode 1, if SM2 = 0, RB8 is the stop bit that was received. In mode 0, RB8 is not used. TI S0CON.1 The transmit interrupt flag. Set by hardware at the end of the 8th bit time in mode 0, or at the beginning of the stop bit in the other modes, in any serial transmission. Must be cleared by software. RI S0CON.0 The receive interrupt flag. Set by hardware at the end of the 8th bit time in mode 0, or halfway through the stop bit time in the other modes, in any serial reception (except see SM2). Must be cleared by software. Table 23. Description of S0CON bits SM0 SM1 MODE 0 0 0 Shift register fCLK/12 0 1 1 8–bit UART variable 1 0 2 9–bit UART fCLK/64 or fCLK/32 1 1 3 9–bit UART variable 1999 Mar 02 DESCRIPTION 29 BAUD RATE Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 The on–chip I2C logic provides a serial interface that meets the I2C–bus specification, supporting all I2C–bus modes of operation, they are: 6.9.2 SIO1 (I2C-bus Interface) The SIO1 of the P8xC557E6 provides the fast–mode, which allows a fourthfold increase of the bitrate up to 400 kHz. Nevertheless it is downward compatible, i.e. it can be used in a 0 to 100 Kbit/s I2C bus system. • Master transmitter • Master receiver • Slave transmitter • Slave receiver Except from the bit rate selection (see Table 25) and the timing of the SCL and SDA signals (see AC electrical characteristics in section 11) the SIO circuit is the same as described in detail in the 80C51 Data Handbook IC20 for the 8xC552 microcontroller. The I2C–bus is a simple bidirectional 2–wire bus for efficient inter–IC data exchange. Features of the I2C–bus are: The SI01 logic performs a byte oriented data transport, clock generation, address recognition and bus control arbitration are all controlled by hardware. Via two pins the external I2C–bus is interfaced to the SIO1 logic: SCL serial clock I/O and SDA serial data I/O, (see Special Function Register bit S1CON.6/ENS1 for enabling the SIO1 logic). • Only two bus lines are required: a serial clock line (SCL) and a serial data line (SDA) • Each device connected to the bus is software addressable by a unique address The SIO1 logic handles byte transfer autonomously. It keeps track of the serial transfers, and a status register (S1STA) reflects the status of SIO1 and the I2C–bus. • Masters can operate as Master–transmitter or as Master–receiver • It’s a true multi–master bus including collision detection and Via the following four Special Function Registers the CPU interfaces to the I2C logic. arbitration to prevent data corruption if two or more masters simultaneously initiate data transfer • Serial clock synchronization allows devices with different bit rates to communicate via the same serial bus • ICs can be added to or removed from an I2C–bus S1CON control register. Bit addressable by the CPU S1STA status register whose contents may be used as a vector to service routines. S1DAT data shift register. The data byte is stable as long as S1CON.3/SI=1. S1ADR slave address register. It’s LSB enables/ disables general call address recognition. system without affecting any other circuit on the bus • Fault diagnostics and debugging are simple; malfunctions can be immediately traced For more information on the I2C–bus specification (including fast–mode) please refer to the Philips publication number 9398 393 40011 and/or the 80C51 Data Handbook IC20. 7 1 SLAVE ADDRESS S1ADR 7 GC 0 SDA INTERNAL BUS SHIFT REGISTER ARBITRATION + SYNC LOGIC S1DAT SCL BUS CLOCK GENERATOR 7 0 S1CON 7 0 S1STA Figure 29. Block diagram of I2C serial I/O interface. 1999 Mar 02 0 30 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 The Control Register, S1CON The CPU can read from and write to this 8-bit, directly addressable SFR. Two bits are affected by the SIO1 hardware: the SI bit is set when a serial interrupt is requested, and the STO bit is cleared when a STOP condition is present on the I2C bus. The STO bit is also cleared when ENS1 = 0. 7 S1CON (D8H) CR2 6 5 ENS1 4 STA STO 3 2 SI AA 1 CR1 0 CR0 Figure 30. Serial control (S1CON) register. Table 24. Description of S1CON bits SYMBOL BIT FUNCTION CR2 S1CON.7 Clock rate bit 2, see Table 25. ENS1 S1CON.6 ENS1 = 0: ENS1 = 1: STA S1CON.5 START flag. When this bit is set in slave mode, the hardware checks the I2C bus and generates a START condition if the bus is free or after the bus becomes free. If the device operates in master mode it will generate a repeated START condition. STO S1CON.4 STOP flag. If this bit is set in a master mode a STOP condition is generated. A STOP condition detected on the I2C bus clears this bit. This bit may also be set in slave mode in order to recover from an error condition. In this case no STOP condition is generated to the I2C bus, but the hardware releases the SDA and SCL lines and switches to the not selected receiver mode. The STOP flag is cleared by the hardware. SI S1CON.3 Serial Interrupt flag. This flag is set, and an interrupt request is generated, after any of the following events occur: Serial I/O Serial I/O disabled and reset. SDA and SCL outputs are high–Z. enabled. – A START condition is generated in master mode. – The own slave address has been received during AA = 1. – The general call address has been received while S1ADR.0 and AA = 1. – A data byte has been received or transmitted in master mode (even if arbitration is lost). – A data byte has been received or transmitted as selected slave. – A STOP or START condition is received as selected slave receiver or transmitter. While the SI flag is set, SCL remains LOW and the serial transfer is su– spended. SI must be reset by software. AA S1CON.2 Assert Acknowledge flag. When this bit is set, an acknowledge is returned after any one of the following conditions: – Own slave address is received. – General call address is received (S1ADR.0 = 1). – A data byte is received, while the device is programmed to be a master receiver. – A data byte is received. while the device is a selected slave receiver. When the bit is reset, no acknowledge is returned. Consequently, no interrupt is requested when the own address or general call address is received. CR1 CR0 1999 Mar 02 S1CON.1 S1CON.0 Clock rate bits 1 and 0, see Table 25. 31 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 When SIO1 is in a master mode serial clock frequency is determined by the clock rate bits CR2, CR1 and CR0. The various bit rates are shown in Table 25. The data shown in Table 25 do not apply to SIO1 in a slave mode. In the slave modes, SIO1 will automatically synchronize with any clock frequency up to 400kHz. Table 25. Selection of I2C-bus bit rate BIT RATE (kHz) at fCLK CR2 CR1 CR0 12MHz 16MHz 1 0 0 50 66.7 1 0 1 3.75 5 1 1 0 75 100 1 1 1 100 – 0 0 0 200 1) 266.7 1) 0 0 1 7.5 10 0 1 0 300 1) 400 1) 0 1 1 400 1) – NOTE: 1. These bit rates are for “fast–mode” I2C bus applications and cannot be used for bit rates up to 100 kbit/sec. Serial status register S1STA S1STA is a read only register. The contents of the status register may be used as a vector to a service routine. This optimizes the response time of the software and consequently that of the I2C–bus. 7 S1STA (D9H) SC4 6 SC3 Figure 31. 5 SC2 4 3 SC1 SC0 Serial status (S1STA) register. Table 26. Description of S1STA bits BIT FUNCTION S1STA.7 to 3 5–bit status code S1STA.2 to 0 These bits are held LOW (for service routine vector increment 8) The following is a list of the status codes: Table 27. MST/TRX mode S1STA VALUE DESCRIPTION 08H A START condition has been transmitted 10H A repeated START condition has been transmitted 18H SLA and W have been transmitted, ACK has been received 20H SLA and W have been transmitted, ACK received 28H DATA and S1DAT has been transmitted, ACK received 30H DATA and S1DAT has been transmitted, ACK received 38H Arbitration lost in SLA, R/W or DATA 1999 Mar 02 32 2 0 1 0 0 0 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Table 28. MST/REC mode S1STA VALUE DESCRIPTION 38H Arbitration lost while returning ACK 40H SLA and R have been transmitted, ACK received 48H SLA and R have been transmitted, ACK received 50H DATA has been received, ACK returned 58H DATA has been received, ACK returned Table 29. SLV/REC mode S1STA VALUE DESCRIPTION 60H Own SLA and W have been received, ACK returned 68H Arbitration lost in SLA, R/W as MST. Own SLA and W have been received, ACK returned 70H General CALL has been received, ACK returned 78H Arbitration lost in SLA, R/W as MST. General call has been received 80H Previously addressed with own SLA. DATA byte received, ACK returned 88H Previously addressed with own SLA. DATA byte received, ACK returned 90H Previously addressed with general call. DATA byte has been received, ACK has been returned 98H Previously addressed with general call. DATA byte has been received, ACK has been returned A0H A STOP condition or repeated START condition has been received while still addressed as SLV/REC or SLV/TRX Table 30. SLV/TRX mode S1STA VALUE DESCRIPTION A8H Own SLA and R have been received, ACK returned B0H Arbitration lost in SLA, R/W as MST. Own SLA and R have been received, ACK returned B8H DATA byte has been transmitted, ACK returned C0H DATA byte has been transmitted, ACK returned C8H Last DATA byte has been transmitted (AA = logic 0), ACK received Table 31. Miscellaneous S1STA VALUE DESCRIPTION 00H Bus error during MST mode or selected SLV mode, due to an erroneous START or STOP condition F8H No relevant information available, SI not set Abbreviations used: SLA : 7–bit slave address R : Read bit W : Write bit ACK : Acknowledgement (acknowledge bit = 0) ACK : Not acknowledgement (acknowledge bit = 1) DATA : 8–bit data byte to or from I2C–bus MST : Master SLV : Slave TRX : Transmitter REC : Receiver 1999 Mar 02 33 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 The data shift register S1DAT This register contains the serial data to be transmitted or data which has been received. Bit 7 is transmitted or received first; i.e. data is shifted from right to left. 7 S1DAT (DAH) S1DAT.7 6 5 4 3 2 1 0 S1DAT.6 S1DAT.5 S1DAT.4 S1DAT.3 S1DAT.2 S1DAT.1 S1DAT.0 Figure 32. Data shift register. The address register S1ADR This 8–bit register may be loaded with the 7–bit slave address to which the controller will respond when programmed as a slave receiver/transmitter. The LSB (GC) is used to determine whether the general call address is recognized. 7 S1ADR (DBH) SLA6 6 5 4 3 2 1 0 SLA5 SLA4 SLA3 SLA2 SLA1 SLA0 GC Figure 33. Address register. Table 32. Description of S1ADR bits SYMBOL BIT SLA6 to 0 S1ADR.7 to 1 GC S1ADR.0 1999 Mar 02 FUNCTION Own slave address 0 = general call address is not recognized 1 = general call address is recognized 34 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Interrupt enable registers Interrupt sources INT0 Source enable Interrupt priority registers Global enable Polling hardware a1 External Interrupt Request 0 a2 I2C Serial Port b1 Timer 0 Overflow f1 c2 g1 d1 h1 d2 i1 e1 Timer 2 Capture 0 f1 Timer 2 Compare 0 CT1I e1 c1 e2 INT1 b1 c1 d1 b2 ADC CT0I a1 High priority interrupt request j1 k1 l1 m1 f2 n1 External Interrupt Request 1 ’seconds’ Interrupt g1 o1 Vector Source Identification g2 h1 Timer 2 Capture 1 h2 a2 i1 Timer 2 Compare 1 b2 i2 Timer 1 Overflow c2 j1 d2 j2 e2 f2 CT2I k1 Timer 2 Capture 2 g2 k2 h2 i2 l2 UART Serial Port CT3I j2 T m1 R m2 l2 n1 m2 n2 n2 Timer 2 Capture 3 o1 Timer T2 Overflow o2 Figure 34. The interrupt system. 1999 Mar 02 Low priority interrupt request l1 Timer 2 Compare 2 35 k2 o2 Vector Source Identification Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 The ADC Interrupt is generated by bit ADINT, which is set when of all selected analog inputs to be scanned, the conversion is finished. ADINT must be cleared by software. It cannot be set by software. 6.10 Interrupt System External events and the real–time–driven on–chip peripherals require service by the CPU asynchronously to the execution of any particular section of code. To tie the asynchronous activities of these functions to normal program execution a multiple–source, two–priority–level, nested interrupt system is provided. Interrupt response time in a single–interrupt system is in the range from 2.25us to 6.75 us when using a 16 MHz crystal. The latency time depends on the sequence of instructions executed directly after an interrupt request. The ‘Seconds’ timer Interrupt is generated by bit SECINT in register PLLCON. This flag has to be cleared by software. Note that the ‘Seconds’ timer can only be used with the 32 kHz PLL oscillator. All of the bits that generate interrupts can be set or cleared by software, with the same result as though it had been set or cleared by hardware (except the ADC interrupt request flag ADINT, which cannot be set by software). That is, interrupts can be generated or pending interrupts can be cancelled in software. The P8xC557E6 acknowledges interrupt requests from 15 sources as follows (see Figure 34): • INT0 and INT1 external interrupts • Timer 0 and Timer 1 internal timer/counter interrupts • Timer 2 internal timer/counter byte and/or 16–bit overflow, The Interrupts X0, T0, X1, T1, SEC, S0 and S1 are capable to terminate the Idle Mode. Interrupt Enable Registers Each interrupt source can be individually enabled or disabled by setting or clearing a bit in the interrupt enable special function registers IEN0 and IEN1. All interrupt sources can also be globally disabled by clearing bit EA in IEN0. The interrupt enable registers are described in Figures 35 and 36. 3 compare and 4 capture interrupts (or 4 additional external interrupts) (1) • UART serial I/O port receive/transmit interrupt • I2C–bus interface serial I/O interrupt • ADC autoscan completion interrupt • ’Seconds’ timer interrupt SEC (ored with INT1). Interrupt Priority Structure Each interrupt source can be assigned one of two priority levels. Interrupt priority levels are defined by the interrupt priority special function registers IP0 and IP1. IP0 and IP1 are described in Figures 37 and 38. For details about seconds timer interrupts, please refer to chapter 6.13.4 Interrupt priority levels are as follows: The External Interrupts INT0 and INT1 can each be either level–activated or transition–activated, depending on bits IT0 and IT1 in register TCON. The flags that actually generate these interrupts are bits IE0 and IE1 in TCON. When an external interrupt is generated, the corresponding request flag is cleared by the hardware when the service routine is vectored to only if the interrupt was transition–activated. If the interrupt was level–activated then the interrupt request flag remains set until the external interrupt pin INTx goes high. Consequently the external source has to hold the request active until the requested interrupt is actually generated. Then it has to deactivate the request before the interrupt service routine is completed, or else another interrupt will be generated. As these external interrupts are active LOW a “wire–ORing” of several interrupt sources to one input pin allows expansion. “0”—low priority “1”—high priority A low priority interrupt may be interrupted by a high priority interrupt. A high priority interrupt cannot be interrupted by any other interrupt source. If two requests of different priority occur simultaneously, the high priority level request is serviced. If requests of the same priority are received simultaneously, an internal polling sequence determines which request is serviced. Thus, within each priority level, there is a second priority structure determined by the polling sequence. This second priority structure is shown in Table 37. Interrupt Handling The interrupt sources are sampled at S5P2 of every machine cycle. The samples are polled during the following machine cycle. If one of the flags was in a set condition at S5P2 of the previous machine cycle, the polling cycle will find it and the interrupt system will generate an LCALL to the appropriate service routine, provided this hardware- generated LCALL is not blocked by any of the following conditions: 1.. An interrupt of higher or equal priority level is already in progress. The Timer 0 and Timer 1 Interrupts are generated by TF0 and TF1, which are set by a rollover in their respective timer/counter register (except for Timer 0 in Mode 3 of the serial interface). When a Timer interrupt is generated, the flag that generated it is cleared by the on–chip hardware when the service routine is vectored to. The eight Timer/Counter T2 Interrupt sources are: 4 capture Interrupts (1), 3 compare interrupts and an overflow interrupt. The appropriate interrupt request flags must be cleared by software. 2.. The current machine cycle is not the final cycle in the execution of the instruction in progress. (No interrupt request will be serviced until the instruction in progress is completed.) The UART Serial Port Interrupt is generated by the logical OR of RI and TI. Neither of these flags is cleared by hardware. The service routine will normally have to determine whether it was RI or TI that generated the interrupt, and the bit will have to be cleared by software. 3.. The instruction in progress is RETI or any access to the interrupt priority or interrupt enable registers. (No interrupt will be serviced after RETI or after a read or write to IP0, IP1, IE0, or IE1 until at least one other instruction has been subsequently executed.) The I2C Interrupt is generated by bit SI in register S1CON. This flag has to be cleared by software. 1. If a capture register is unused and it’s contents is of no interest, then the corresponding input pin CTnI/P1.n (n: 0...3) may be used as a (configurable) positive and/or negative edge triggered additional external interrupt input (INT2, INT3, INT4, INT5). 1999 Mar 02 36 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 The polling cycle is repeated with every machine cycle, and the values polled are the values present at S5P2 of the previous machine cycle. Note that if an interrupt flag is active but is not being responded to because of one of the above conditions, and if the flag is inactive when the blocking condition is removed, then the blocked interrupt will not be serviced. Thus, the fact that the interrupt flag was once active but not serviced is not remembered. Every polling cycle is new. interrupt flags. An external interrupt flag (IE0 or IE1) is cleared only if it was transition-activated. All other interrupt flags are not cleared by hardware and must be cleared by the software. The LCALL pushes the contents of the program counter on to the stack (but it does not save the PSW) and reloads the PC with an address that depends on the source of the interrupt being vectored to as shown in Table 38. Execution proceeds from the vector address until the RETI instruction is encountered. The RETI instruction clears the “priority level active” flip-flop that was set when this interrupt was acknowledged. It then pops the top two bytes from the stack and reloads the program counter. Execution of the in– terrupted program continues from where it was interrupted. The processor acknowledges an interrupt request by executing a hardware-generated LCALL to the appropriate service routine. In some cases it also clears the flag which generated the interrupt, and in others it does not. It clears the Timer 0, Timer 1, and external 7 IEN0 (A8H) EA 6 5 4 3 2 1 0 EAD ES1 ES0 ET1 EX1 ET0 EX0 2 1 0 Figure 35. Interrupt enable register (IEN0). Table 33. Description of IEN0 bits SYMBOL BIT EA IEN0.7 Global enable/disable control 0= No interrupt is enabled 1= Any individually enabled interrupt will be accepted FUNCTION EAD IEN0.6 Enable ADC interrupt ES1 IEN0.5 Enable SIO1 (I2C) interrupt ES0 IEN0.4 Enable SIO0 (UART) interrupt ET1 IEN0.3 Enable Timer 1 interrupt EX1 IEN0.2 Enable External interrupt 1 / Seconds interrupt ET0 IEN0.1 Enable Timer 0 interrupt EX0 IEN0.0 Enable External interrupt 0 7 IEN1 (E8H) ET2 6 ECM2 5 4 ECM1 ECM0 3 ECT3 Figure 36. Interrupt enable register (IEN1). Table 34. Description of IEN1 bits SYMBOL BIT ET2 IEN1.7 Enable T2 overflow interrupt(s) FUNCTION ECM2 IEN1.6 Enable T2 comparator 2 interrupt ECM1 IEN1.5 Enable T2 comparator 1 interrupt ECM0 IEN1.4 Enable T2 comparator 0 interrupt ECT3 IEN1.3 Enable T2 capture register 3 interrupt ECT2 IEN1.2 Enable T2 capture register 2 interrupt ECT1 IEN1.1 Enable T2 capture register 1 interrupt ECT0 IEN1.0 Enable T2 capture register 0 interrupt If the enable bit is 0, then the interrupt is disabled, if the enable bit is 1, then the interrupt is enabled. 1999 Mar 02 37 ECT2 ECT1 ECT0 Philips Semiconductors Product specification Single-chip 8-bit microcontroller 7 IP0 (B8H) – 6 PAD P83C557E6/P80C557E6 5 PS1 4 3 2 1 0 PS0 PT1 PX1 PT0 PX0 2 1 0 Figure 37. Interrupt priority register (IP0). Table 35. Description of IP0 bits SYMBOL BIT FUNCTION – IP0.7 Reserved for future use PAD IP0.6 ADC interrupt priority level PS1 IP0.5 SIO1 (I2C) interrupt priority level PS0 IP0.4 SIO0 (UART) interrupt priority level PT1 IP0.3 Timer 1 interrupt priority level PX1 IP0.2 External interrupt 1/Seconds interrupt priority level PT0 IP0.1 Timer 0 interrupt priority level PX0 IP0.0 External interrupt 0 priority level 7 IP1 (F8H) PT2 6 PCM2 5 PCM1 4 PCM0 3 PCT3 Figure 38. Interrupt priority register (IP1). Table 36. Description of IP1 bits SYMBOL BIT FUNCTION PT2 IP1.7 T2 overflow interrupt(s) priority level PCM2 IP1.6 T2 comparator 2 interrupt priority level PCM1 IP1.5 T2 comparator 1 interrupt priority level PCM0 IP1.4 T2 comparator 0 interrupt priority level PCT3 IP1.3 T2 capture register 3 interrupt priority level PCT2 IP1.2 T2 capture register 2 interrupt priority level PCT1 IP1.1 T2 capture register 1 interrupt priority level PCT0 IP1.0 T2 capture register 0 interrupt priority level 1999 Mar 02 38 PCT2 PCT1 PCT0 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Table 37. Interrupt Priority Structure SOURCE NAME PRIORITY WITHIN LEVEL (highest) External interrupt 0 SIO1 (I2C) ADC completion Timer 0 overflow Timer 2 capture 0 Timer 2 compare 0 External interrupt 1/Seconds interrupt Timer 2 capture 1 Timer 2 compare 1 Timer 1 overflow Timer 2 capture 2 Timer 2 compare 2 SIO0 (UART) Timer 2 capture 3 Timer 2 overflow X0 S1 ADC T0 CT0 CM0 X1/SEC CT1 CM1 T1 CT2 CM2 S0 CT3 T2 ↑ ↓ (lowest) Table 38. Interrupt Vector Addresses SOURCE External interrupt 0 Timer 0 overflow External interrupt 1/Seconds interrupt Timer 1 overflow SIO0 (UART) SIO1 (I2C) Timer 2 capture 0 Timer 2 capture 1 Timer 2 capture 2 Timer 2 capture 3 ADC completion Timer 2 compare 0 Timer 2 compare 1 Timer 2 compare 2 Timer 2 overflow 1999 Mar 02 39 NAME VECTOR ADDRESS X0 T0 X1/SEC T1 S0 S1 CT0 CT1 CT2 CT3 ADC CM0 CM1 CM2 T2 0003H 000BH 0013H 001BH 0023H 002BH 0033H 003BH 0043H 004BH 0053H 005BH 0063H 006BH 0073H Philips Semiconductors Product specification Single-chip 8-bit microcontroller PCON (87H) P83C557E6/P80C557E6 7 6 5 4 3 2 1 0 SMOD ARD RFI WLE GF1 GF0 PD IDL Figure 39. Power control register (PCON). Table 39. Description of PCON bits SYMBOL BIT FUNCTION SMOD PCON.7 Double Baud rate bit. When set to logic 1 the baud rate is doubled when the serial port SIO0 is being used in modes 1, 2, or 3. ARD PCON.6 AUX–RAM disable bit. When set to a 1 the internal 1280 bytes AUX–RAM is disabled, so that all MOVX–Instructions access the external data memory – as it is with the standard PCB80C51. RFI PCON.5 Reduced radio frequency interference bit. When set to a 1 the toggling of ALE pin is prohibited. This bit is cleared on RESET (see also sections Features (EMC) and Pinning). WLE PCON.4 Watchdog load enable. This flag must be set by software prior to loading timer T3 (watchdog timer). It is cleared when timer T3 is loaded. GF1 PCON.3 General-purpose flag bit GF0 PCON.2 General-purpose flag bit PD PCON.1 Power-down bit. Setting this bit activates the power-down mode. It can only be set if input EW is high. IDL PCON.0 Idle Mode bit. Setting this bit activates the Idle Mode. PCON is not bit addressable. The reset value of PCON is (00000000). 6.11 Power Reduction Modes Two software–selectable modes of reduced power consumption are implemented. These are the Idle Mode and the Power–down Mode. 6.11.2 Idle Mode The instruction that sets PCON.0 is the last instruction executed in the normal operating mode before Idle Mode is activated. Once in the Idle Mode, the CPU status is preserved in its entirety: the Stack Pointer, Program Counter, Program Status Word, Accumulator, RAM and all other registers maintain their data during Idle Mode. The status of external pins during Idle Mode is shown in Table 40. Idle Mode operation permits the interrupt, serial ports and timer blocks T0, T1 and T3 to function while the CPU is halted. The following functions are switched off when the microcontroller enters the Idle Mode: • CPU • Timer 2 • PWM0, PWM1 • ADC (halted) (stopped and reset) There are three ways to terminate the Idle Mode: (reset, output = HIGH) Activation of any enabled interrupt X0, T0, X1, SEC, T1, S0 or S1 will cause PCON.0 to be cleared by hardware terminating Idle Mode but only, if there is no interrupt in service with the same or higher priority. The interrupt is serviced, and following return from interrupt instruction RETI, the next instruction to be executed will be the one which follows the instruction that wrote a logic 1 to PCON.0. (aborted if conversion in progress) The following functions remain active during Idle Mode. These functions may generate an interrupt or reset and thus terminate the Idle Mode: • Timer 0, Timer 1, Timer 3 (Watchdog timer) • UART • I2C • External interrupt • Seconds Timer The flag bits GF0 and GF1 may be used to determine whether the interrupt was received during normal execution or during Idle Mode. For example, the instruction that writes to PCON.0 can also set or clear one or both flag bits. When Idle Mode is terminated by an interrupt, the service routine can examine the status of the flag bits. The second way of terminating the Idle Mode is with an external hardware reset. Since the oscillator is still running, the hardware reset is required to be active for two machine cycles (24 HF oscillator periods) to complete the reset operation if the HF oscillator is selected. In Power–down Mode the system clock is halted. If the PLL oscillator is selected (SELXTAL1 = 0) and the RUN32 bit is set, the 32 kHz oscillator keeps running, otherwise it is stopped. If the HF–oscillator (SELXTAL1 = 1) is selected, it is stopped after setting the bit PD in the PCON register. When the PLL oscillator is selected a hardware reset of > 1 µsec (but no longer than 10 ms) is required and the microcontroller will typically restart within 63 msec after the reset has finished. 6.11.1 Power Control Register The modes Idle and Power–down are activated by software via the Special Function Register PCON. Its hardware address is 87H. 1999 Mar 02 The third way of terminating the Idle Mode is by internal watchdog reset. The microcontroller restarts after 3 machine cycles in all cases. 40 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Table 40. External Pin Status During Idle and Power-Down Modes MEMORY ALE PSEN PORT 0 PORT 1 PORT 2 PORT 3 PORT 4 SCL/SDA PWM0/PWM1 Idle MODE Internal 1 1 data data data data data operative (1) HIGH Idle External 1 1 high – Z data address data data operative (1) HIGH Power-down Internal 0 0 data data data data data high–Z HIGH Power-down External 0 0 high – Z data data data data high–Z HIGH NOTE: 1. In Idle Mode SCL and SDA can be active as outputs only if SIO1 is enabled; if SIO1 is disabled (S1CON.6/ENS1 = 0) these pins are in a high–impedance state. 32 kHz XTAL4 SELXTAL1 XTAL3 PLL Osc Interrupts, Serial Ports, T0, T1, T3 fCLK Clock Gen. Seconds timer CPU T2 ADC PWM Osc XTAL1 3.5 to 16 MHz XTAL2 PD IDL Figure 40. Idle and Power Down Hardware for Clock Generation 6.11.4 Wake-up from Power-down Mode The Power-down Mode of the P8xC557E6 can also be terminated by any one of the three enabled interrupts, INT0, INT1 or Seconds interrupt. 6.11.3 Power-down Mode The instruction that sets PCON.1 is the last executed prior to going into the Power-down Mode. Once in Power-down Mode, the HF oscillator is stopped. The 32 kHz oscillator may stay running. The content of the on-chip RAM and the Special Function Registers are preserved. Note that the Power-down Mode can not be entered when the watchdog has been enabled. If there is an interrupt already in service, which has same or higher priority as the Wake-up interrupt, Power-down Mode will switch over to Idle Mode and stay there until an interrupt of higher priority terminates Idle Mode. The Power-down Mode can be terminated by an external RESET in the same way as in the 80C51 (RAM is saved, but SFRs are cleared due to RESET) or in addition by any one of the external interrupts (INT0, INT1) or Seconds interrupt. A termination with these interrupts does not affect the internal data memory and does not affect the Special Function Registers. This gives the possibility to exit Power-down without changing the port output levels. To terminate the Power-down Mode with an external interrupt, INT0 or INT1 must be switched to be level-sensitive and must be enabled. The external interrupt input signal INT0 or INT1 must be kept LOW till the oscillator has restarted and stabilized (see Figure 41). A Seconds interrupt will terminate the Power-down Mode if it is enabled and INT1 is level sensitive. In order to prevent any interrupt priority problems during Wake-up, the priority of the desired Wake-up interrupt should be higher than the priorities of all other enabled interrupt sources. The status of the external pins during Power-down Mode is shown in Table 40. If the Power-down Mode is activated while in external program memory, the port data that is held in the Special Function Register P2 is restored to Port 2. If the data is a logic1, the port pin is held HIGH during the Power-down Mode by the strong pull-up transistor P1 (see Figure 9). The Power-down Mode should not be entered within an interrupt routine because Wake-up with an external or ‘Seconds’ interrupt is not possible in that case. The instruction following the one that put the device into the Power-down Mode will be the first one which will be executed after the interrupt routine has been serviced. 1999 Mar 02 41 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Internal timing stopped oscillator start_up > 10 ms LCALL Interrupt routine interrupts are polled INT0 : 2 cycles INT1 : 1 cycle > 560 ms > 10 ms 32 kHz oscillator stopped running INT0 INT1 C2 C1 Idle Mode Power–down Mode XTAL1,2 oscillator stopped C1 C1 set External Interrupt latch Figure 41. Wake-up by interrupt 1 SELXTAL1 1 • Quartz crystal or ceramic resonator • • XTAL1 C1 C2 SELXTAL1 External clock signal XTAL1 (NC) XTAL2 XTAL2 VSS C1 = C2 = 20pF VSS Figure 43. Using an external clock. Figure 42. Using the On-Chip Oscillator. 6.12 Oscillator Circuits 6.13 32 kHz PLL Oscillator with Seconds Timer The input signal SELXTAL1 connected to logic “1” selects the XTAL1, 2 oscillator (standard 80C51) instead of the XTAL3, 4 oscillator, which is halted and XTAL3, 4 must not be connected. 6.13.1 XTAL3,4 Oscillator Circuitry The input signal SELXTAL1 connected to logic “0” selects the 32kHz oscillator together with the PLL instead of the XTAL1,2 oscillator, which is halted. XTAL2 is floating in that case. 6.12.1 XTAL1, 2 Oscillator circuit (standard 80C51) The oscillator circuit of the P8xC557E6 is a single–stage inverting amplifier in a Pierce oscillator configuration. The circuitry between the XTAL1 and XTAL2 is basically an inverter biased to the transfer point. Either a crystal or ceramic resonator can be used as the feedback element to complete the oscillator circuitry. Both are operated in parallel resonance. XTAL1 is the high gain amplifier input, and XTAL2 is the output (see Figure 42). To drive the P8xC557E6 externally, XTAL1 is driven from an external source and XTAL2 left open–circuit (see Figure 43). The 32kHz oscillator consists of an inverter, which forms a Pierce oscillator with the on–chip components C1,C2,Rf and an external crystal of 32768 Hz. During the following situations, the inverter is switched to tristate and XTAL3 is pulled to Vss : • during Power–down Mode, when the PLL control register bit RUN32 (PLLCON.7) was set to ‘0’; • during Reset (RSTIN = HIGH) ; • when the XTAL1,2 oscillator is selected (SELXTAL1 = HIGH). 6.12.2 XTAL3, 4 Circuitry Please refer to chapter 6.13.1 1999 Mar 02 42 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 6.13.3 PLL Control Register – PLLCON PLLCON is a special function register, which can be read and written by software. It contains the control bits: 6.13.2 PLL CCO A current controlled oscillator (CCO) generates a clock frequency fCCO of approx. 32 , 38 , 44 or 50 MHz , controlled by the PLL, with the 32kHz oscillator as the reference clock. The system clock frequency fCLK can be varied under software control by changing the contents of the PLL control register (PLLCON): • to select one of several system clock frequencies (see Table 41) • the seconds interrupt flag: SECINT • to enable the seconds interrupt flag: ENSECI • the RUN32 bit, which defines if during Power–down Mode the fCCO can be changed via the PLLCON bits FSEL(1:0) (see Table 41). The maximum locking time is 10 ms (2). During the stabilization phase, no time critical routines should be executed. 32kHz oscillator is halted or stays running . PLLCON is initialized to 0DH upon Reset (RSTIN = ‘1’) or Watchdog Timer Overflow. PLLCON = 0DH corresponds to a system clock frequency of 11.01 MHz. The system clock frequency fCLK is derived from fCCO under control of the PLLCON bits FSEL(4:0) (see Table 41). If only FSEL(4:2) is changed but not FSEL(1:0), then it takes about 1us until the new frequency is available. Changing the system clock frequency has to be done in two steps. From HIGH to LOW frequencies: First change (FSEL(4:2), then FSEL (1:0). From LOW to HIGH frequencies: First change only FSEL (1:0) and after a stabilization phase of 10 ms change FSEL (4:2). 7 PLLCON (F9H) RUN32 6 5 4 3 2 1 0 ENSECI SECINT FSEL.4 FSEL.3 FSEL.2 FSEL.1 FSEL.0 Figure 44. PLL control register (PLLCON). Table 41. PLLCON SYMBOL BIT FUNCTION RUN32 PLLCON.7 RUN32 = 0: The 32 kHz oscillator halts during Power–down. RUN32 = 1: The 32 kHz oscillator stays running during Power–down. ENSECI PLLCON.6 Enable the seconds interrupt. (enabling INT1 is also required) SECINT PLLCON.5 Seconds interrupt requested by an overflow of the seconds timer (which occurs every second) or via writing a ‘1’ to this bit. SECINT can only be cleared by writing a ‘0’ to this bit . FSEL.4 PLLCON.4 System clock frequency in MHz to FSEL.0 to PLLCON.0 FSEL[4:2] 100 11 FSEL[1:0]10 01 00 3.93 4.72 5.51 6.29 011 010 7.86 9.44 11.01 12.58 15.73 Other combinations, than mentioned above, are reserved and may not be selected . This allows to generate the standard baudrates 19200, 9600, 4800, 2400 and 1200 Baud , when using the UART and Timer1. 2. This parameter is characterized. 1999 Mar 02 43 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 6.13.4 Seconds Timer This counter provides an overflow signal every second, when the 32kHz oscillator is running. Power–down. It controls the stretching of the reset pulse to the microcontroller and controls releasing the system clock to the microcontroller. The overflow output sets the interrupt flag SECINT. This interrupt can be disabled/enabled by ENSECI. If SECINT is enabled, it is logically ORed with INT1 (external interrupt 1). A RSTIN signal of 1us at minimum will reset the microcontroller. In case of Reset or Wake–up with halted 32kHz oscillator: From RSTIN falling edge or Wake–up interrupt it takes 560ms at maximum for the start–up of the 32kHz oscillator itself and the stabilization of the PLL’s. Seconds interrupt and INT1 therefor share the same priority and vector. The software has to check both flags SECINT (PLLCON.5) and IE1 (TCON.3), to distinguish between the two interrupt sources. SECINT can only be cleared via writing a ‘0’ to this bit . In case of Wake–up with running 32kHz oscillator: From Wake–up interrupt it takes about 1ms for the stabilization of the PLL’s. The external interrupts INT0 , INT1 or the seconds interrupt can Wake–up the PLL oscillator and the microcontroller as described in chapter “Wake–up from Power–down Mode”. After this start–up time, the microcontroller is supplied with the system clock and – in case of a reset – the internally stretched reset signal overlaps about 45us, to guarantee a proper initialization of the microcontroller. For a Wake–up via INT1 or seconds interrupt, IE1 must be enabled and level–sensitive. For further information refer to section 6.11 Power reduction modes. A further function of the seconds timer is to control the start–up timing of the microcontroller after Reset or after Wake–up from 32.768 KHz XTAL4 C1 C2 XTAL3 PD Rf 32 kHz Phase comparator Loop filter CCO Oscil– lator Programmable divider system clock Stretched Reset RUN32 PD Reset to controller PLLCON SECONDS TIMER ’Seconds’ Interrupt request RSTIN Internal Bus PD = power down Figure 45. Block diagram PLL 1999 Mar 02 44 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 6.14 Reset Circuitry 6.15 Power-on Reset The reset input pin RSTIN is connected to a Schmitt trigger for noise reduction (see Figure 46). Is the HF–oscillator selected a Reset is accomplished by holding the RSTIN pin HIGH for at least 2 machine cycles (24 system clock periods). Is the PLL–oscillator selected the RSTIN–pulse must have a width of 1 µs at least, independent of the 32 kHz–oscillator is running or not (see PLL description). The CPU responds by executing an internal reset. The RSTOUT pin represents the signal resetting the CPU and can be used to reset peripheral devices. An automatic Reset can be obtained by switching on VDD, if the RSTIN pin is connected to VDD via a capacitor, as shown in Figure 47. If the HF oscillator selected the VDD rise time must not exceed 10 ms and the capacitor should be at least 2.2 µF. The decrease of the RSTIN pin voltage depends on the capacitor and the internal resistor RRST. That voltage must remain above the lower threshold for at minimum the HF–oscillator start–up time plus 2 machine cycles. Is the PLL–oscillator selected a 0.1 µF capacitor is sufficient to obtain an automatic reset. The RSTOUT level also could be high due to a Watchdog timer overflow. The length of the output pulse from T3 is 3 machine cycles. A pulse of such short duration is necessary in order to recover from a processor or system fault as fast as possible. During Reset, ALE and PSEN output a HIGH level. In order to perform a correct reset, this level must not be affected by external elements. A Reset leaves the internal registers as shown in Table 5. The internal RAM is not affected by Reset. At power-on, the RAM content is indeterminate. VDD Schmitt Trigger SELXTAL1 Internal Reset Capacitor for HF_osc.: MUX RSTIN On-chip resistor VDD PLL OSC RSTOUT RRST PLL_osc.: 0.1 F RST RRST Overflow timer T3 Figure 46. On–chip Reset Configuration 1999 Mar 02 8xC557E6 2.2 F Figure 47. Power–on Reset 45 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 7.1.1 80C51 Family Instruction Set 7. INSTRUCTION SET The P8xC557E6 uses the powerful instruction set of the PCB80C51. It consists of 49 single–byte, 45 two–byte and 17 three–byte instructions. Using a 16 MHz quartz, 64 of the instructions are executed in 0.75 µs, 45 in 1,5 µs and the multiply, divide instructions in 3 µs. Table 42. Instruction that affect Flag settings1 INSTRUCTION A summary of the instruction set is given in Table 43. The P8xC557E6 has additional Special Function Registers to control the on–chip peripherals. 7.1 Addressing Modes Most instructions have a “destination, source” field that specifies the data type, addressing modes and operands involved. For all these instructions, except for MOVs, the destination operand is also the source operand (e.g., ADD A,R7). There are five kinds of addressing modes: • Register Addressing – R0 – R7 (4 banks) – A,B,C (bit), AB (2 bytes), DPTR (double byte) • Direct Addressing – lower 128 bytes of internal Main RAM (including the 4 R0–R7 register banks) C OV AC ADD ADDC SUBB MUL DIV DA RRC RLC SETB C X X X 0 0 X X X 1 X X X X X X X X X CLR C CPL C ANL C, bit ANL C,/bit ANL C, bit ORL C, bit MOV C, bit CJNE 0 X X X X X X X NOTE: 1. Note that operations on SFR byte address 208 or bit addresses 209-215 (i.e., the PSW or bits in the PSW) will also affect flag settings. – Special Function Registers – 128 bits in a subset of the internal Main RAM – 128 bits in a subset of the Special Function Registers Notes on instruction set and addressing modes: • Register–Indirect Addressing – internal Main RAM (@R0, @R1, @SP [PUSH/POP]) – internal Auxiliary RAM (@R0, @R1, @DPTR) Rn Register R7-R0 of the currently selected Register Bank. direct 8-bit internal data location’s address. This could be an Internal Data RAM location (0-127) or a SFR [i.e., I/O port, control register, status register, etc. (128-255)]. @Ri 8-bit RAM location addressed indirectly through register R1 or R0 of the actual register bank. #data 8-bit constant included in the instruction. #data 16 16-bit constant included in the instruction addr 16 16-bit destination address. Used by LCALL and LJMP. A branch can be anywhere within the 64 Kbytes Program Memory address space. addr 11 11-bit destination address. Used by ACALL and AJMP. The branch will be within the same 2 Kbytes page of program memory as the first byte of the following instruction. rel Signed (two’s complement) 8-bit offset byte. Used by SJMP and all conditional jumps. Range is –128 to +127 bytes relative to first byte of the following instruction. bit Direct Addressed bit in Internal Data RAM or Special Function Register. – external Data Memory (@R0, @R1, @DPTR) • Immediate Addressing – Program Memory (in–code 8 bit or 16 bit constant) • FLAG Base–Register–plus Index–Register–Indirect Addressing – Program Memory look–up table (@DPTR+A, @PC+A) The first three addressing modes are usable for destination operands. Hexadecimal opcode cross-reference to Table 43 1999 Mar 02 46 * : 8, 9, A, B, C, D, E. F. ** : 11, 31, 51, 71, 91, B1, D1, F1. *** : 01, 21, 41, 61, 81, A1, C1, E1. Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Table 43. 80C51 Instruction Set Summary MNEMONIC DESCRIPTION BYTE / CYCLES OPCODE (HEX.) ARITHMETIC OPERATIONS ADD A,Rn Add register to Accumulator 1 1 2* ADD A,direct Add direct byte to Accumulator 2 1 25 ADD A,@Ri Add indirect RAM to Accumulator 1 1 26, 27 ADD A,#data Add immediate data to Accumulator 2 1 24 ADDC A,Rn Add register to Accumulator with carry 1 1 3* ADDC A,direct Add direct byte to Accumulator with carry 2 1 35 ADDC A,@Ri Add indirect RAM to Accumulator with carry 1 1 36, 37 ADDC A,#data Add immediate data to ACC with carry 2 1 34 SUBB A,Rn Subtract Register from ACC with borrow 1 1 9* SUBB A,direct Subtract direct byte from ACC with borrow 2 1 95 SUBB A,@Ri Subtract indirect RAM from ACC with borrow 1 1 96, 97 SUBB A,#data Subtract immediate data from ACC with borrow 2 1 94 INC A Increment Accumulator 1 1 04 INC Rn Increment register 1 1 0* INC direct Increment direct byte 2 1 05 INC @Ri Increment indirect RAM 1 1 06, 07 DEC A Decrement Accumulator 1 1 14 DEC Rn Decrement Register 1 1 1* DEC direct Decrement direct byte 2 1 15 DEC @Ri Decrement indirect RAM 1 1 16, 17 INC DPTR Increment Data Pointer 1 2 A3 MUL AB Multiply A and B 1 4 A4 DIV AB Divide A by B 1 4 84 DA A Decimal Adjust Accumulator 1 1 D4 LOGICAL OPERATIONS ANL A,Rn AND Register to Accumulator 1 1 5* ANL A,direct AND direct byte to Accumulator 2 1 55 ANL A,@Ri AND indirect RAM to Accumulator 1 1 56, 57 ANL A,#data AND immediate data to Accumulator 2 1 54 ANL direct,A AND Accumulator to direct byte 2 1 52 ANL direct,#data AND immediate data to direct byte 3 2 53 ORL A,Rn OR register to Accumulator 1 1 4* ORL A,direct OR direct byte to Accumulator 2 1 45 ORL A,@Ri OR indirect RAM to Accumulator 1 1 46, 47 ORL A,#data OR immediate data to Accumulator 2 1 44 ORL direct,A OR Accumulator to direct byte 2 1 42 ORL direct,#data OR immediate data to direct byte 3 2 43 XRL A,Rn Exclusive-OR register to Accumulator 1 1 6* XRL A,direct Exclusive-OR direct byte to Accumulator 2 1 65 XRL A,@Ri Exclusive-OR indirect RAM to Accumulator 1 1 66, 67 1999 Mar 02 47 Philips Semiconductors Product specification Single-chip 8-bit microcontroller Table 43. P83C557E6/P80C557E6 80C51 Instruction Set Summary (Continued) MNEMONIC DESCRIPTION BYTE / CYCLES OPCODE (HEX.) LOGICAL OPERATIONS (Continued) XRL A,#data Exclusive-OR immediate data to Accumulator 2 1 64 XRL direct,A Exclusive-OR Accumulator to direct byte 2 1 62 XRL direct,#data Exclusive-OR immediate data to direct byte 3 2 63 CLR A Clear Accumulator 1 1 E4 CPL A Complement Accumulator 1 1 F4 RL A Rotate Accumulator left 1 1 23 RLC A Rotate Accumulator left through the carry 1 1 33 RR A Rotate Accumulator right 1 1 03 RRC A Rotate Accumulator right through the carry 1 1 13 SWAP A Swap nibbles within the Accumulator 1 1 C4 DATA TRANSFER MOV A,Rn Move register to Accumulator 1 1 E* MOV A,direct Move direct byte to Accumulator 2 1 E5 MOV A,@Ri Move indirect RAM to Accumulator 1 1 E6, E7 MOV A,#data Move immediate data to Accumulator 2 1 74 MOV Rn,A Move Accumulator to register 1 1 F* MOV Rn,direct Move direct byte to register 2 2 A* MOV RN,#data Move immediate data to register 2 1 7* MOV direct,A Move Accumulator to direct byte 2 1 F5 MOV direct,Rn Move register to direct byte 2 2 8* MOV direct,direct Move direct byte to direct 3 2 85 MOV direct,@Ri Move indirect RAM to direct byte 2 2 86, 87 MOV direct,#data Move immediate data to direct byte 3 2 75 MOV @Ri,A Move Accumulator to indirect RAM 1 1 F6, F7 MOV @Ri,direct Move direct byte to indirect RAM 2 2 A6, A7 MOV @Ri,#data Move immediate data to indirect RAM 2 1 76, 77 MOV DPTR,#data16 Load Data Pointer with a 16-bit constant 3 2 90 MOVC A,@A+DPTR Move Code byte relative to DPTR to ACC 1 2 93 MOVC A,@A+PC Move Code byte relative to PC to ACC 1 2 83 MOVX A,@Ri Move AUX–RAM (8-bit addr) to ACC 1 2 E2, E3 MOVX A,@DPTR Move AUX–RAM (16-bit addr) to ACC 1 2 E0 MOVX @Ri,A Move ACC to AUX–RAM (8-bit addr) 1 2 F2, F3 MOVX @DPTR,A Move ACC to AUX–RAM (16-bit addr) 1 2 F0 PUSH direct Push direct byte onto stack 2 2 C0 POP direct Pop direct byte from stack 2 2 D0 XCH A,Rn Exchange register with Accumulator 1 1 C* XCH A,direct Exchange direct byte with Accumulator 2 1 C5 XCH A,@Ri Exchange indirect RAM with Accumulator 1 1 C6, C7 XCHD A,@Ri Exchange low-order digit indirect RAM with ACC 1 1 D6, D7 1999 Mar 02 48 Philips Semiconductors Product specification Single-chip 8-bit microcontroller Table 43. P83C557E6/P80C557E6 80C51 Instruction Set Summary (Continued) MNEMONIC DESCRIPTION BYTE / CYCLES OPCODE (HEX.) BOOLEAN VARIABLE MANIPULATION CLR C Clear carry 1 1 C3 CLR bit Clear direct bit 2 1 C2 SETB C Set carry 1 1 D3 SETB bit Set direct bit 2 1 D2 CPL C Complement carry 1 1 B3 CPL bit Complement direct bit 2 1 B2 ANL C,bit AND direct bit to carry 2 2 B2 ANL C,/bit AND complement of direct bit to carry 2 2 B0 ORL C,bit OR direct bit to carry 2 2 72 ORL C,/bit OR complement of direct bit to carry 2 2 A0 MOV C,bit Move direct bit to carry 2 1 A2 MOV bit,C Move carry to direct bit 2 2 92 JC rel Jump if carry is set 2 2 40 JNC rel Jump if carry not set 2 2 50 JB rel Jump if direct bit is set 2 2 20 JNB rel Jump if direct bit is not set 2 2 30 JBC bit,rel Jump if direct bit is set and clear bit 3 2 10 PROGRAM BRANCHING ACALL addr11 Absolute subroutine call 2 2 **1addr LCALL addr16 Long subroutine call 3 2 12 RET Return from subroutine 1 2 22 RETI Return from interrupt 1 2 32 AJMP addr11 Absolute jump 2 2 ***1addr LJMP addr16 Long jump 3 2 02 SJMP rel Short jump (relative addr) 2 2 80 JMP @A+DPTR Jump indirect relative to the DPTR 1 2 73 JZ rel Jump if Accumulator is zero 2 2 60 JNZ rel Jump if Accumulator is not zero 2 2 70 CJNE A,direct,rel Compare direct byte to ACC and jump if not equal 3 2 B5 CJNE A,#data,rel Compare immediate to ACC and jump if not equal 3 2 B4 CJNE RN,#data,rel Compare immediate to register and jump if not equal 3 2 B* CJNE @Ri,#data,rel Compare immediate to indirect and jump if not equal 3 2 B6, B7 DJNZ Rn,rel Decrement register and jump if not zero 2 2 D* DJNZ direct,rel Decrement direct byte and jump if not zero 3 2 D5 No operation 1 1 00 NOP NOTE: 1. All mnemonics copyrighted 1999 Mar 02 Intel Corporation 1980 49 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Table 44. Instruction map P8xC557E6 second hexadecimal character of opcode 0 1 2 3 first hexadecimal character of opcode 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 NOP AJMP LJMP RR INC INC addr11 addr16 A A dir JBC ACALL LCALL RRC DEC DEC bit, rel addr11 addr16 A A dir JB AJMP RET RL ADD ADD bit, rel addr11 A A, #data A, dir JNB ACALL RLC ADDC ADDC bit, rel addr11 A A, #data A, dir JC AJMP ORL ORL ORL ORL rel addr11 dir, A dir, #data A, #data A, dir JNC ACALL ANL ANL ANL ANL rel addr11 dir, A dir, #data A, #data A, dir JZ AJMP XRL XRL XRL XRL rel addr11 dir, A dir, #data A, #data A, dir JNZ ACALL ORL JMP MOV MOV rel addr11 C, bit @A+DPTR A, #data dir,#data SJMP AJMP ANL MOVC DIV MOV rel addr11 C, bit A, @A+PC AB dir, dir MOV ACALL MOV MOVC SUBB SUBB DPTR,#data16 addr11 bit, C A,@A+DPTR A, #data A, dir ORL AJMP MOV INC MUL C,/bit addr11 C, bit DPTR AB ANL ACALL CPL CPL CJNE CJNE CJNE @Ri,#data,rel C,/bit addr11 bit C A,#data,rel A,dir, rel 0 PUSH AJMP CLR CLR SWAP XCH dir addr11 bit C A A, dir POP ACALL SETB SETB DA DNJZ dir addr11 bit C A dir, rel MOVX AJMP MOVX A, @Ri CLR MOV A, @DPTR addr11 0 A A, dir *) MOVX ACALL MOVX A, @Ri, A CPL MOV @DPTR, A addr11 0 A dir, A RETI 1 1 7 8 9 0 1 0 1 2 1 0 1 2 1 0 1 2 1 0 1 2 1 0 1 2 1 0 1 2 1 0 1 2 1 0 1 1 2 0 1 2 0 1 2 0 1 2 1 0 1 2 1 0 1 2 5 6 7 3 4 6 7 5 6 7 5 6 7 5 6 7 5 6 7 6 7 6 7 6 7 6 7 5 3 4 3 4 3 4 3 4 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 6 7 6 7 6 7 6 7 6 7 XCH A, Rr XCHD A, @ Ri 3 4 5 DJNZ Rr, rel 1 0 1 2 MOV A, @ Ri 3 4 5 MOV A, Rr 1 0 1 2 MOV @ Ri, A 0 4 CJNE Rr, #data, rel XCH A, @ Ri 0 3 MOV Rr, dir 1 0 7 SUBB A, Rr 1 0 6 MOV dir, Rr SUBB A, @ Ri 0 5 MOV Rr, #data MOV dir, @ Ri 0 4 XRL A, Rr MOV @ Ri, #data 0 3 ANL A, Rr XRL A, @ Ri 0 F ORL A, Rr ANL A, @ Ri 0 E ADDC A, Rr ORL A, @ Ri 0 D ADD A, Rr ADDC A, @ Ri 0 C DEC Rr ADD A, @ Ri 0 B INC Rr DEC @ Ri 0 0 50 A INC @ Ri MOV @ Ri, dir *) MOV A, ACC is not a valid instruction 1999 Mar 02 6 3 4 5 MOV Rr, A 1 0 1 2 3 4 5 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 9. ABSOLUTE MAXIMUM RATINGS ABSOLUTE MAXIMUM RATINGS1, 2, 3 RATING UNIT Storage temperature range –65 to +150 °C Voltage on VDD to VSS and SCL, SDA to VSS –0.5 to +6.5 V Input / output current on any I/O pin 10 mA Power dissipation (based on package heat transfer limitations, not device power consumption) 1.0 W PARAMETER NOTES: 1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any conditions other than those described in the AC and DC Electrical Characteristics section of this specification is not implied. 2. This product includes circuitry specifically designed for the protection of its internal devices from the damaging effects of excessive static charge. Nonetheless, it is suggested that conventional precautions are taken to avoid applying greater than the rated maxima. 3. Parameters are valid over operating temperature range unless otherwise specified. All voltages are with respect to VSS unless otherwise noted. 1999 Mar 02 51 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 10. DC CHARACTERISTICS DC ELECTRICAL CHARACTERISTICS VDD = 5V (± 10%), VSS = 0V, Tamb = 0°C to +70°C (P8xC557E6EBx). All voltages with respect to VSS unless otherwise specified. LIMITS SYMBOL PARAMETER VDD Supply voltage IDD Supply current operating: TEST CONDITIONS P83C557E6 IID Supply current Idle Mode: P83C557E6 Supply current Power-down mode IPD Supply current Power-down mode: 32 kHz / PLL operation UNIT MIN MAX 4.5 5.5 V See notes 1 and 2 fCLK = 16MHz VDD = 5.5 V 40 mA See notes 1 and 3 fCLK = 16MHz VDD = 5.5 V 12 mA See note 4 2 V < VPD < VDDmax 100 µA 100 µA See note 17 VDD = 5.5 V Inputs VIL Input LOW voltage, except EA, SCL, SDA –0.5 0.2VDD–0.1 V VIL1 Input LOW voltage to EA –0.5 0.2VDD–0.3 V VIL2 Input LOW voltage to SCL, SDA 5 –0.5 0.3VDD V VIH Input HIGH voltage, except XTAL1, RSTIN, SCL, SDA, ADEXS 0.2VDD+0.9 VDD+0.5 V VIH1 Input HIGH voltage, XTAL1, RSTIN, ADEXS 0.7VDD VDD+0.5 V 0.7VDD 6.0 V VIN = 0.45 V –50 µA See note 6 –650 µA 5 VIH2 Input HIGH voltage, SCL, SDA IIL Input current LOW level, Ports 1, 2, 3, 4 ITL Transition current HIGH to LOW, Ports 1, 2, 3, 4 ±ILI1 Input leakage current, Port 0, EA, ADEXS, EW, SELXTAL1 0.45 V < VI < VDD 10 µA ±ILI2 Input leakage current, SCL, SDA 0 V < VI < 6 V 0 V < VDD < 5.5 V 10 µA ±ILI3 Input leakage current, Port 5 0.45 V < VI < VDD 1 µA IOL = 1.6mA7 0.45 V 3.2mA7 0.45 V IOL = 3.0mA7, 19 0.4 V 6.0mA7, 19 0.6 Outputs VOL Output low voltage, Ports 1, 2, 3, 4 VOL1 Output low voltage, Port 0, ALE, PSEN, PWM0, PWM1, RSTOUT VOL2 Output low voltage, SCL, SDA IOL = IOL = VOH Output high voltage, Ports 1, 2, 3, 4 VOH1 Output high voltage (Port 0 in external bus mode, ALE, PSEN, PWM0, PWM1, RSTOUT) 8 VHYS Hysteresis of Schmitt Trigger inputs SCL, SDA (Fast-mode) NOTES: See Page 54. 1999 Mar 02 52 VDD = 5 V ± 10% –IOH = 60µA –IOH = 25µA –IOH = 10µA 2.4 0.75VDD 0.9VDD V V V VDD = 5 V ± 10% –IOH = 800µA –IOH = 300µA –IOH = 80µA 2.4 0.75VDD 0.9VDD V V V 0.05VDD 20 V Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 DC ELECTRICAL CHARACTERISTICS (Continued) VDD = 5 V (± 10%), VSS = 0 V, Tamb = –40°C to +85°C (P8xC557E6EFx). DC parameters not included here are the same as in the P8xC557E6EBx, DC electrical characteristics. All voltages with respect to VSS unless otherwise specified. TEST SYMBOL PARAMETER RRST Internal reset pull-down resistor CIO Pin capacitance LIMITS CONDITIONS MIN MAX UNIT 50 150 kΩ 10 pF –0.5 0.2VDD–0.15 V Test freq = 1MHz, Tamb = 25 °C Inputs VIL Input LOW voltage, except EA, SCL, SDA VIL1 Input LOW voltage to EA VIH Input HIGH voltage, except XTAL1, RSTIN, SCL, SDA, ADEXS VIH1 Input HIGH voltage, XTAL1, RSTIN, ADEXS IIL Input current LOW level, Ports 1, 2, 3, 4 ITL Transition current HIGH to LOW, Ports 1, 2, 3, 4 –0.5 0.2VDD–0.35 V 0.2VDD+1.0 VDD+0.5 V 0.7VDD+0.1 VDD+0.5 V VIN = 0.45 V –75 µA See note 6 –750 µA NOTES: See Page 54. DC ELECTRICAL CHARACTERISTICS ANALOG AVDD = 5 V (± 10%), AVSS = 0 V, Tamb = 0 °C to +70 °C (P8xC557E6EBx). AVDD = 5 V (± 10%), AVSS = 0 V, Tamb = –40 °C to +85 °C (P8xC557E6EFx). All voltages with respect to VSS unless otherwise specified. TEST SYMBOL AVDD AIDD AIID PARAMETER CONDITIONS MIN MAX UNIT Analog supply voltage AVDD = VDD ± 0.2 V 4.5 5.5 V Analog supply current operating Port 5 = 0 to AVDD see notes 1 and 2 1.2 mA Analog supply current operating: 32 kHz/PLL operation Port 5 = 0 to AVDD see note 17, 18 7.2 mA Analog supply current Idle Mode see notes 1 and 3 70 A Analog supply current Idle Mode: 32 kHz/PLL operation Supply current Power-down mode AIPD LIMITS Supply current Power-down mode: 32 kHz/PLL operation see note 17 6.0 mA 2 V < VPD < VDDmax see note 4 50 µA VDD = 5.5V see note 17 200 µA AVDD+0.2 V AVDD+0.2 V V Analog Inputs AVIN Analog input voltage AVSS–0.2 AVREF Reference voltage: AVREF– AVREF+ AVSS–0.2 RREF Resistance between AVREF+ and AVREF– 50 kΩ CIA Analog input capacitance 15 pF DLe Differential non-linearity 9, 10, 11, ±1 LSB ILe Integral non-linearity 9, 12 ±2 LSB OSe Offset error 9, 13 ±2 LSB error 9, 14 Ge Gain Ae Absolute voltage error 9, 15 MCTC Channel to channel matching Ct 10 Crosstalk between inputs of port 5 16 0–100kHz NOTES: See Page 54. 1999 Mar 02 53 ±0.4 % ±3 LSB ±1 LSB –60 dB Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 NOTES FOR DC ELECTRICAL CHARACTERISTICS: 1. See Figures 48 and 50 through 52 for IDD test conditions. 2. The operating supply current is measured with all output pins disconnected; XTAL1 driven with tr = tf = 5ns; VIL = VSS + 0.5 V; VIH = VDD – 0.5 V; XTAL2, XTAL3 not connected; EA = RSTIN = Port 0 = EW = SCL = SDA = SELXTAL1 = VDD; ADEXS = XTAL4 = VSS. 3. The Idle Mode supply current is measured with all output pins disconnected; XTAL1 driven with tr = tf = 5ns; VIL = VSS + 0.5 V; VIH = VDD – 0.5 V; XTAL2, XTAL3 not connected; Port 0 = EW = SCL = SDA = SELXTAL 1 = VDD; EA = RSTIN = ADEXS = XTAL4 = VSS. 4. The Power-down current is measured with all output pins disconnected; XTAL2 not connected; Port 0 = EW = SCL = SDA = SELXTAL 1 = VDD; EA = RSTIN = ADEXS = XTAL1 = XTAL4 = VSS. 5. The input threshold voltage of SCL and SDA (SIO1) meets the I2C specification, so an input voltage below 0.3 VDD will be recognized as a logic 0 while an input voltage above 0.7 VDD will be recognized as a logic 1. 6. Pins of ports 1, 2, 3, and 4 source a transition current when they are being externally driven from HIGH to LOW. The transition current reaches its maximum value when VIN is approximately 2 V. 7. Capacitive loading on ports 0 and 2 may cause spurious noise to be superimposed on the VOL of ALE and ports 1, 3 and 4. The noise is due to external bus capacitance discharging into the port 0 and port 2 pins when these pins make 1-to-0 transitions during bus operations. In the worst cases (capacitive loading > 100pF), the noise pulse on the ALE pin may exceed 0.8 V. In such cases, it may be desirable to qualify ALE with a Schmitt Trigger, or use an address latch with a Schmitt Trigger STROBE input. 8. Capacitive loading on ports 0 and 2 may cause the VOH on ALE and PSEN to momentarily fall below the 0.9VDD specification when the address bits are stabilizing. 9. Conditions: AVREF– = 0 V; AVDD = 5.0 V, AVREF+ = 5.12 V. VDD = 5.0 V, VSS = 0 V, ADC is monotonic with no missing codes. Measurement by continuous conversion of AVIN = –20mV to 5.12 V in steps of 0.5mV, derivating parameters from collected conversion results of ADC. ADC prescaler programmed according to the actual oscillator frequency, resulting in a conversion time within the specified range for tconv (15µs ... 50µs). 10. The differential non-linearity (DLe) is the difference between the actual step width and the ideal step width. 11. The ADC is monotonic; there are no missing codes. 12. The integral non-linearity (ILe) is the peak difference between the center of the steps of the actual and the ideal transfer curve after appropriate adjustment of gain and offset error. 13. The offset error (OSe) is the absolute difference between the straight line which fits the actual transfer curve (after removing gain error), and a straight line which fits the ideal transfer curve. The offset error is constant at every point of the actual transfer curve. 14. The gain error (Ge) is the relative difference in percent between the straight line fitting the actual transfer curve (after removing offset error), and the straight line which fits the ideal transfer curve. Gain error is constant at every point on the transfer curve. 15. The absolute voltage error (Ae) is the maximum difference between the center of the steps of the actual transfer curve of the non-calibrated ADC and the ideal transfer curve. 16. This should be considered when both analog and digital signals are simultaneously input to port 5. 17. The supply current with 32 kHz oscillator running and PLL operation (SELXTAL1 = 0) is measured with all output pins disconnected; XTAL4 driven with tr = tf = 5ns; VIL = VSS + 0.5 V; VIH = VDD – 0.5 V; XTAL2 not connected; Port 0 = EW = SCL = SDA = VDD; EA = RSTIN = ADEXS = SELXTAL 1 = XTAL1 = VSS. 18. Not 100% tested; sum of AIID (PLL) and AIDD (HF–Oscillator). 19. The parameter meets the I2C bus specification for standard–mode and fast–mode devices. 20. Not 100% tested. (1) 40 30 IDD (mA) 20 (2) 10 0 0 4 8 f (MHz) 12 (1) Maximum operating mode P83C557E6/P80C557E6 (2) Maximum Idle Mode P83C557E6/P80C557E6 16 : : VDD = 5.5 V VDD = 5.5 V Figure 48. Supply Current (IDD) as a Function of Frequency at XTAL1 1999 Mar 02 54 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Offset error OSe 1023 1022 1021 1020 1019 1018 (2) 7 Code Out (1) 6 5 (5) 4 (4) 3 (3) 2 1 1 LSB (ideal) 0 1 2 3 4 5 6 7 1018 1019 1020 1021 1022 AVIN (LSBideal) Offset error OSe (1) (2) (3) (4) (5) 1 LSB = Example of an actual transfer curve. The ideal transfer curve. Differential non-linearity (DLe). Integral non-linearity (ILe). Center of a step of the actual transfer curve. Figure 49. ADC Conversion Characteristic 1999 Mar 02 55 AVREF+ – AVREF– 1024 1023 1024 Gain error Ge Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 11. AC CHARACTERISTICS AC ELECTRICAL CHARACTERISTICS VDD = 5 V ± 10% (EBx), VSS = 0 V, tCLK min = 1/fmax (maximum operating frequency) VDD = 5 V ± 10% (EFx), VSS = 0 V, tCLK min = 1/fmax (maximum operating frequency) Tamb = 0 °C to +70 °C, tCLK min = 63 ns for P8xC557E6EBx Tamb = –40 °C to +85 °C, tCLK min = 63 ns for P8xC557E6EFx C1 = 100 pF for Port 0, ALE and PSEN ; C1 = 80 pF for all other outputs unless otherwise specified. 12MHz CLOCK SYMBOL FIGURE PARAMETER MIN MAX 16MHz CLOCK MIN MAX VARIABLE CLOCK MIN MAX UNIT 3.5 16 MHz 1/tCLK 53 System clock frequency tLHLL 53 ALE pulse width 127 85 2tCLK–40 ns tAVLL 53 Address valid to ALE LOW 43 23 tCLK–40 ns tLLAX 53 Address hold after ALE LOW 53 33 tCLK–30 ns tLLIV 53 ALE LOW to valid instruction in tLLPL 53 ALE LOW to PSEN LOW 53 33 tCLK–30 ns tPLPH 53 PSEN pulse width 205 143 3tCLK–45 ns tPLIV 53 PSEN LOW to valid instruction in tPXIX 53 Input instruction hold after PSEN tPXIZ 53 Input instruction float after PSEN 59 38 tCLK–25 ns tAVIV 53 Address to valid instruction in 312 208 5tCLK–105 ns tPLAZ 53 PSEN LOW to address float 10 10 10 ns tAVLL 54, 55 Address valid to ALE LOW tLLAX 54, 55 Address hold after ALE LOW 48 tRLRH 54 RD pulse width 400 tWLWH 55 WR pulse width 400 275 tRLDV 54 RD LOW to valid data in tRHDX 54 Data hold after RD tRHDZ 54 Data float after RD 97 55 2tCLK–70 ns tLLDV 54 ALE LOW to valid data in 517 350 8tCLK–150 ns tAVDV 54 Address to valid data in 9tCLK–165 ns tLLWL 54, 55 ALE LOW to RD or WR LOW 200 3tCLK+50 ns tAVWL 54, 55 Address valid to WR LOW or RD LOW 203 tQVWX 55 Data valid to WR transition 33 tQVWH 55 Data before WR 433 tWHQX 55 Data hold after WR 33 13 tRLAZ 54 RD low to address float tWHLH 54, 55 234 150 145 0 4tCLK–100 83 0 3tCLK–105 0 ns ns ns Data Memory RD or WR HIGH to ALE HIGH 43 23 tCLK–40 ns 28 tCLK–35 ns 275 6tCLK–100 ns 6tCLK–100 ns 252 0 148 0 585 300 0 398 138 238 120 123 3tCLK–50 ns ns 4tCLK–130 ns 13 tCLK–50 ns 288 7tCLK–150 ns tCLK–50 ns 0 43 5tCLK–165 0 23 103 tCLK–40 0 ns tCLK+40 ns UART Timing – Shift Register Mode (Test Conditions: Tamb = 0 °C to +70 °C; VSS = 0 V; Load Capacitance = 80pF) tXLXL 57 Serial port clock cycle time 1.0 0.75 12tCLK µs tQVXH 57 Output data setup to clock rising edge 700 492 10tCLK–133 ns tXHQX 57 Output data hold after clock rising edge 50 8 2tCLK–117 ns tXHDX 57 Input data hold after clock rising edge 0 0 0 ns tXHDV 57 Clock rising edge to input data valid 1999 Mar 02 700 56 492 10tCLK–133 ns Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 AC ELECTRICAL CHARACTERISTICS (Continued) SYMBOL I2C Standard-mode I2C-bus PARAMETER Fast-mode I2C-bus UNIT MIN MAX MIN MAX 0 100 0 400 kHz Interface timing (refer to Figure 56) fSCL SCL clock frequency tBUF Bus free time between a STOP and START condition 4.7 – 1.3 – µs tHD; STA Hold time (repeated) START condition. After this period, the first clock pulse is generated 4.0 – 0.6 – µs tLOW LOW period of the SCL clock 4.7 – 1.3 – µs tHIGH High period of the SCL clock 4.0 – 0.6 – µs tSU; STA Set–up time for a repeated START condition 4.7 – 0.6 – µs tHD; DAT Data hold time: for CBUS competible masters (see Section 9, Notes 1, 3) for I2C–bus devices 5.0 01 – 01 – 0.92 tSU; DAT Data set–up time 250 – 1003 – ns tFD, tFC Rise time of both SDA and SCL signals – 1000 20 + 0.1Cb4 300 ns tFD, tFC Fall time of both SDA and SCL signals – 300 20 + 0.1Cb4 300 ns tSU; STO Set–up time for STOP condition 4.0 – 0.6 – µs Cb Capacitive load for each bus line – 400 – 400 pF tSP Pulse width of spikes which must be suppressed by the input filter – – 0 50 ns µs All values referred to VIH and VIL max levels. NOTES: 1. A device must internally provide a hold time of at least 300 ns from the SDA signal (referred to the VIH min of the SCL signal) in order to bridge the undefined region of the falling edge of SCL. 2. The maximum tHD,DAT has only to be met if the device does not stretch the LOW period (tLOW) of the SCL signal. 3. A fast–mode I2C–bus device can be used in a standard–mode I2C–bus system, but the requirement tSU,DAT ≥ 250 ns must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line tRmax + tSU,DAT = 1000 + 250 = 1250 ns (according to the standard–mode I2C–bus specification) before the SCL line is released. 4. Cb = total capacitance of one bus line in pF. Table 45. External clock drive XTAL1 (refer to Figure 50) SYMBOL VARIABLE CLOCK fCLK = 3.5 to 16 MHz PARAMETER MIN MAX UNIT tCLK XTAL1 Period 63 286 ns tCLKH XTAL1 HIGH time 20 – ns tCLKL XTAL1 LOW time 20 – ns tCLKR XTAL1 rise time – 20 ns tCLKF XTAL1 fall time tCYC 1) Controller cycle time NOTE: 1. tCYC = 12 fCLK 1999 Mar 02 57 – 20 ns 0.75 3.4 µs Philips Semiconductors Product specification Single-chip 8-bit microcontroller tCLKH VIH1 P83C557E6/P80C557E6 tCLKR tCLKF VIH1 VIH1 0.8V VIH1 0.8V tCLKL tCLK Figure 50. External Clock Drive waveform Float 2.4 V 2.4 V 2.0 V 2.0 V 2.4 V 2.0 V 2.0 V 0.8 V 0.8 V Test Points 0.8 V 0.8 V 0.45 V 0.45 V NOTE: AC inputs during testing are driven at 2.4V for a logic ‘HIGH’ and 0.45V for a logic ‘LOW’. Timing measurements are made at 2.0 V for a logic ‘HIGH’ and 0.8 V for a logic ‘LOW’. NOTE: The float state is defined as the point at which a port 0 pin sinks 3.2mA or sources 400A at the voltage test levels. Figure 51. AC Testing Input/Output Figure 52. AC Testing, Float Waveform tLHLL ALE tAVLL tLLPL tPLPH tLLIV PSEN tPLIV tLLAX PORT 0 tPXIZ tPLAZ tPXIX INSTR IN A0–A7 A0–A7 tAVIV PORT 2 A8–A15 A8–A15 Figure 53. External Program Memory Read Cycle 1999 Mar 02 58 0.45 V Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 ALE tWHLH PSEN tLLDV tLLWL tRLRH RD tAVLL tLLAX tRHDZ tRLDV tRHDX tRLAZ A0–A7 FROM RI OR DPL PORT 0 DATA IN A0–A7 FROM PCL INSTR IN tAVWL tAVDV PORT 2 P2.0–P2.7 OR A8–A15 FROM DPH A8–A15 FROM PCH Figure 54. External Data Memory Read Cycle ALE tWHLH PSEN tLLWL tWLWH WR tAVLL PORT 0 tLLAX A0–A7 FROM RI OR DPL tWHQX tQVWX tQVWH DATA OUT A0–A7 FROM PCL tAVWL PORT 2 P2.0–P2.7 OR A8–A15 FROM DPH Figure 55. External Data Memory Write Cycle 1999 Mar 02 59 A8–A15 FROM PCH INSTR IN Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 repeated START condition START or repeated START condition START condition tSU;STA STOP condition tRD SDA (INPUT/OUTPUT) 0.7 VDD 0.3 VDD tBUF tFD tRC tFC tSP tSU; STO 0.7 VDD SCL (INPUT/OUTPUT) 0.3 VDD tSU;DAT3 tHD;STA tLOW tHIGH tSU;DAT1 tHD;DAT tSU;DAT2 Figure 56. Timing SIO1 (I2C) Interface INSTRUCTION 0 1 2 3 4 5 6 7 8 ALE tXLXL CLOCK tXHQX tQVXH OUTPUT DATA 0 1 2 3 4 5 6 7 WRITE TO SBUF tXHDX tXHDV SET TI INPUT DATA VALID VALID VALID VALID VALID VALID VALID VALID CLEAR RI SET RI Figure 57. UART waveforms in Shift Register Mode 1999 Mar 02 60 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 One Machine Cycle XTAL1 INPUT dotted lines are valid when RD or WR are active only active during a read from external data memory only active during a write from external data memory external program memory fetch S1 S2 S3 S4 S5 S6 S1 S2 S3 S4 S5 S6 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 ALE PSEN RD WR Bus (Port 0) Int. in Port 2 read or write of external data memory One Machine Cycle Bus (Port 0) Port 2 PORT OUTPUT address A0–A7 address A0–A7 Int. in address A8–A15 Int. in address A0–A7 Int. in Int. in address A8–A15 address A0–A7 address A8–A15 address A0–A7 address A8–A15 data output or data input address A8–A15 or Port2 out old data Int. in address A0–A7 address A8–A15 address A0–A7 address A8–A15 new data PORT INPUT sampling time of I/O port pins during input (including INT0 and INT1) SERIAL PORT CLOCK Figure 58. Instruction cycle timing Purchase of Philips I2C components conveys a license under the Philips’ I2C patent to use the components in the I2C system provided the system conforms to the I2C specifications defined by Philips. This specification can be ordered using the code 9398 393 40011. 1999 Mar 02 61 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 QFP80: plastic quad flat package; 80 leads (lead length 1.95 mm); body 14 x 20 x 2.7 mm; high stand-off height 1999 Mar 02 62 SOT318-1 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 NOTES 1999 Mar 02 63 Philips Semiconductors Product specification Single-chip 8-bit microcontroller P83C557E6/P80C557E6 Data sheet status Data sheet status Product status Definition [1] Objective specification Development This data sheet contains the design target or goal specifications for product development. Specification may change in any manner without notice. Preliminary specification Qualification This data sheet contains preliminary data, and supplementary data will be published at a later date. Philips Semiconductors reserves the right to make chages at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Philips Semiconductors reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. [1] Please consult the most recently issued datasheet before initiating or completing a design. Definitions Short-form specification — The data in a short-form specification is extracted from a full data sheet with the same type number and title. For detailed information see the relevant data sheet or data handbook. Limiting values definition — Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information — Applications that are described herein for any of these products are for illustrative purposes only. Philips Semiconductors make no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Disclaimers Life support — These products are not designed for use in life support appliances, devices or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips Semiconductors customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips Semiconductors for any damages resulting from such application. Right to make changes — Philips Semiconductors reserves the right to make changes, without notice, in the products, including circuits, standard cells, and/or software, described or contained herein in order to improve design and/or performance. Philips Semiconductors assumes no responsibility or liability for the use of any of these products, conveys no license or title under any patent, copyright, or mask work right to these products, and makes no representations or warranties that these products are free from patent, copyright, or mask work right infringement, unless otherwise specified. Copyright Philips Electronics North America Corporation 1999 All rights reserved. Printed in U.S.A. Philips Semiconductors 811 East Arques Avenue P.O. Box 3409 Sunnyvale, California 94088–3409 Telephone 800-234-7381 Date of release: 03-99 Document order number: 1999 Mar 02 64 9397 750 05315