APT40GLQ120JCU2 VCES = 1200V IC = 40A @ Tc = 80°C ISOTOP® Boost chopper High speed Trench + Field Stop IGBT4 Application • AC and DC motor control • Switched Mode Power Supplies • Power Factor Correction • Brake switch K CR1 C G Features • High speed Trench + Field Stop IGBT 4 Technology - Low voltage drop - Low leakage current - Low switching losses - RBSOA and SCSOA rated • SiC Schottky Diode (CR1) - Zero reverse recovery - Zero forward recovery - Temperature Independent switching behavior - Positive temperature coefficient on VF • • • ISOTOP® Package (SOT-227) Very low stray inductance High level of integration E K E C G ISOTOP® Benefits • Low conduction losses • Stable temperature behavior • Very rugged • Direct mounting to heatsink (isolated package) • Low junction to case thermal resistance • Easy paralleling due to positive TC of VCEsat • RoHS Compliant All ratings @ Tj = 25°C unless otherwise specified Absolute maximum ratings ICM VGE PD RBSOA TC = 25°C TC = 80°C TC = 25°C Continuous Collector Current Pulsed Collector Current Gate – Emitter Voltage Maximum Power Dissipation Reverse Bias Safe Operating Area TC = 25°C Tj = 150°C Max ratings 1200 80 40 160 ±20 312 80A @ 1100V Unit V November, 2012 IC Parameter Collector - Emitter Breakdown Voltage A V W These Devices are sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed. See application note APT0502 on www.microsemi.com www.microsemi.com 1-6 APT40GLQ120JCU2 – Rev 0 Symbol VCES APT40GLQ120JCU2 Electrical Characteristics Symbol Characteristic ICES Zero Gate Voltage Collector Current VCE(sat) Collector Emitter saturation Voltage VGE(th) IGES Gate Threshold Voltage Gate – Emitter Leakage Current Test Conditions VGE = 0V, VCE = 1200V Tj = 25°C VGE =15V IC = 40A Tj = 150°C VGE = VCE, IC = 1mA VGE = ±20V, VCE = 0V Min Typ 1.7 2.05 2.6 5.8 Test Conditions VGE = 0V VCE = 25V f = 1MHz Min 5.0 Max 25 2.4 Unit µA 6.5 120 V nA Max Unit V Dynamic Characteristics Symbol Cies Coes Cres QG Characteristic Input Capacitance Output Capacitance Reverse Transfer Capacitance Gate charge Td(on) Tr Turn-on Delay Time Rise Time Td(off) Turn-off Delay Time Tf Td(on) Tr Td(off) Fall Time Turn-on Delay Time Rise Time Turn-off Delay Time Tf Fall Time Eon Turn-on Switching Energy Eoff Turn-off Switching Energy Isc Short Circuit data VGE = 15V, IC = 40A VCE = 960V Resistive Switching (25°C) VGE = ±15V VBus = 600V IC = 40A RG = 12Ω Inductive Switching (150°C) VGE = ±15V VBus = 600V IC = 40A RG = 12Ω Tj = 25°C VGE = ±15V VBus = 600V Tj = 150°C IC = 40A Tj = 25°C RG = 12Ω Tj = 150°C VGE ≤15V ; VBus = 600V tp ≤10µs ; Tj = 150°C Typ 2300 150 130 pF 185 nC 30 57 ns 290 16 30 49 366 ns 48 1.9 2.25 1.2 2.25 mJ 150 A Chopper SiC diode ratings and characteristics (CR1) IF Maximum Reverse Leakage Current VR=1200V DC Forward Current VF Diode Forward Voltage QC Total Capacitive Charge C Total Capacitance Min 1200 Tj = 25°C Tj = 175°C Tc = 100°C Tj = 25°C IF = 20A Tj = 175°C IF = 20A, VR = 600V di/dt =1000A/µs Typ Max 64 112 20 1.6 2.3 400 2000 80 f = 1MHz, VR = 200V 192 f = 1MHz, VR = 400V 138 www.microsemi.com Unit V µA A 1.8 3 V November, 2012 IRM Test Conditions nC pF 2-6 APT40GLQ120JCU2 – Rev 0 Symbol Characteristic VRRM Maximum Peak Repetitive Reverse Voltage APT40GLQ120JCU2 Thermal and package characteristics Symbol Characteristic Min Typ IGBT SiC Diode RthJC Junction to Case Thermal Resistance RthJA VISOL TJ,TSTG TL Torque Wt Junction to Ambient (IGBT & Diode) RMS Isolation Voltage, any terminal to case t =1 min, 50/60Hz Storage Temperature Range Max Lead Temp for Soldering:0.063” from case for 10 sec Mounting torque (Mounting = 8-32 or 4mm Machine and terminals = 4mm Machine) Package Weight Max 0.48 0.8 20 4000 -55 Unit °C/W V 150 300 1.5 29.2 °C N.m g SOT-227 (ISOTOP®) Package Outline 11.8 (.463) 12.2 (.480) 31.5 (1.240) 31.7 (1.248) 8.9 (.350) 9.6 (.378) Hex Nut M4 (4 places) W=4.1 (.161) W=4.3 (.169) H=4.8 (.187) H=4.9 (.193) (4 places) 7.8 (.307) 8.2 (.322) r = 4.0 (.157) (2 places) 25.2 (0.992) 0.75 (.030) 12.6 (.496) 25.4 (1.000) 0.85 (.033) 12.8 (.504) 4.0 (.157) 4.2 (.165) (2 places) 3.3 (.129) 3.6 (.143) 1.95 (.077) 2.14 (.084) Collector Cathode 14.9 (.587) 15.1 (.594) 30.1 (1.185) 30.3 (1.193) * Emitter terminals are shorted internally. Current handling capability is equal for either Emitter terminal. 38.0 (1.496) 38.2 (1.504) Emitter Gate Dimensions in Millimeters and (Inches) Operating Frequency vs Collector Current 240 200 VCE=600V D=50% R G=12Ω T J=150°C T C=75°C ZVS 160 ZCS November, 2012 120 80 40 hard switching 0 0 10 20 30 40 50 IC (A) www.microsemi.com 3-6 APT40GLQ120JCU2 – Rev 0 Fmax, Operating Frequency (kHz) Typical IGBT Performance Curve APT40GLQ120JCU2 Output Characteristics (VGE=15V) Output Characteristics 80 80 TJ = 150°C VGE=20V 60 TJ=25°C VGE=13V 40 IC (A) IC (A) 60 TJ=150°C VGE=15V 40 VGE=9V 20 20 0 0 0 0.5 1 1.5 2 2.5 VCE (V) 3 3.5 0 4 8 TJ=25°C 6 E (mJ) 50 40 TJ=150°C 30 3 4 VCE (V) VCE = 600V VGE = 15V RG = 12Ω TJ = 150°C 70 60 2 5 6 Energy losses vs Collector Current Transfert Characteristics 80 IC (A) 1 Eon 4 Eoff 2 20 10 TJ=25°C 0 5 6 7 8 0 9 10 11 0 12 20 40 60 80 IC (A) VGE (V) Switching Energy Losses vs Gate Resistance Reverse Bias Safe Operating Area 4 100 VCE = 600V VGE =15V IC = 40A TJ = 150°C 80 IC (A) E (mJ) 3 Eon Eoff 60 40 2 VGE=15V TJ=150°C RG=12Ω 20 1 0 10 15 20 25 30 Gate Resistance (ohms) 35 0 300 600 VCE (V) 900 1200 maximum Effective Transient Thermal Impedance, Junction to Case vs Pulse Duration D = 0.9 0.3 0.2 0.1 0.7 0.5 November, 2012 0.4 0.3 0.1 0.05 0 0.00001 Single Pulse 0.0001 0.001 0.01 0.1 rectangular Pulse Duration (Seconds) www.microsemi.com 1 10 4-6 APT40GLQ120JCU2 – Rev 0 Thermal Impedance (°C/W) 0.5 APT40GLQ120JCU2 Typical chopper SiC diode Performance Curve Maximum Effective Transient Thermal Impedance, Junction to Case vs Pulse Duration Thermal Impedance (°C/W) 1 0.8 D = 0.9 0.6 0.7 0.5 0.4 0.3 0.2 0.1 0.05 Single Pulse 0 0.00001 0.0001 0.001 0.01 0.1 1 10 Rectangular Pulse Duration (Seconds) Reverse Characteristics Forward Characteristics 40 200 30 IR Reverse Current (µA) IF Forward Current (A) TJ=25°C TJ=75°C 20 TJ=125°C 10 TJ=175°C 150 100 0 0 0.5 1 1.5 2 2.5 3 3.5 VF Forward Voltage (V) TJ=75°C TJ=125°C 50 TJ=175°C 0 400 600 TJ=25°C 800 1000 1200 1400 1600 VR Reverse Voltage (V) Capacitance vs.Reverse Voltage 1200 1000 800 600 400 200 1 10 100 VR Reverse Voltage November, 2012 0 1000 ISOTOP® is a registered trademark of ST Microelectronics NV www.microsemi.com 5-6 APT40GLQ120JCU2 – Rev 0 C, Capacitance (pF) 1400 APT40GLQ120JCU2 DISCLAIMER The information contained in the document (unless it is publicly available on the Web without access restrictions) is PROPRIETARY AND CONFIDENTIAL information of Microsemi and cannot be copied, published, uploaded, posted, transmitted, distributed or disclosed or used without the express duly signed written consent of Microsemi. If the recipient of this document has entered into a disclosure agreement with Microsemi, then the terms of such Agreement will also apply. This document and the information contained herein may not be modified, by any person other than authorized personnel of Microsemi. No license under any patent, copyright, trade secret or other intellectual property right is granted to or conferred upon you by disclosure or delivery of the information, either expressly, by implication, inducement, estoppels or otherwise. Any license under such intellectual property rights must be approved by Microsemi in writing signed by an officer of Microsemi. Microsemi reserves the right to change the configuration, functionality and performance of its products at anytime without any notice. This product has been subject to limited testing and should not be used in conjunction with lifesupport or other mission-critical equipment or applications. Microsemi assumes no liability whatsoever, and Microsemi disclaims any express or implied warranty, relating to sale and/or use of Microsemi products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Any performance specifications believed to be reliable but are not verified and customer or user must conduct and complete all performance and other testing of this product as well as any user or customers final application. User or customer shall not rely on any data and performance specifications or parameters provided by Microsemi. It is the customer’s and user’s responsibility to independently determine suitability of any Microsemi product and to test and verify the same. The information contained herein is provided “AS IS, WHERE IS” and with all faults, and the entire risk associated with such information is entirely with the User. Microsemi specifically disclaims any liability of any kind including for consequential, incidental and punitive damages as well as lost profit. The product is subject to other terms and conditions which can be located on the web at http://www.microsemi.com/legal/tnc.asp Life Support Application Seller's Products are not designed, intended, or authorized for use as components in systems intended for space, aviation, surgical implant into the body, in other applications intended to support or sustain life, or for any other application in which the failure of the Seller's Product could create a situation where personal injury, death or property damage or loss may occur (collectively "Life Support Applications"). Buyer agrees not to use Products in any Life Support Applications and to the extent it does it shall conduct extensive testing of the Product in such applications and further agrees to indemnify and hold Seller, and its officers, employees, subsidiaries, affiliates, agents, sales representatives and distributors harmless against all claims, costs, damages and expenses, and attorneys' fees and costs arising, directly or directly, out of any claims of personal injury, death, damage or otherwise associated with the use of the goods in Life Support Applications, even if such claim includes allegations that Seller was negligent regarding the design or manufacture of the goods. www.microsemi.com 6-6 APT40GLQ120JCU2 – Rev 0 November, 2012 Buyer must notify Seller in writing before using Seller’s Products in Life Support Applications. Seller will study with Buyer alternative solutions to meet Buyer application specification based on Sellers sales conditions applicable for the new proposed specific part.