PD - 97448 IRLML2060TRPbF HEXFET® Power MOSFET VDS 60 V VGS Max ± 16 V RDS(on) max 480 mΩ 640 mΩ (@VGS = 10V) RDS(on) max (@VGS = 4.5V) * ' 6 Micro3TM (SOT-23) IRLML2060TRPbF Application(s) • Load/ System Switch Features and Benefits Features Benefits Industry-standard pinout Compatible with existing Surface Mount Techniques RoHS compliant containing no lead, no bromide and no halogen MSL1 Multi-vendor compatibility results in Easier manufacturing ⇒ Environmentally friendly Increased reliability Absolute Maximum Ratings Symbol VDS Parameter Max. Units 60 V ID @ TA = 25°C Drain-Source Voltage Continuous Drain Current, VGS @ 10V 1.2 ID @ TA = 70°C Continuous Drain Current, VGS @ 10V 0.93 IDM Pulsed Drain Current 4.8 PD @TA = 25°C Maximum Power Dissipation 1.25 PD @TA = 70°C Maximum Power Dissipation 0.80 Linear Derating Factor 0.01 VGS Gate-to-Source Voltage ± 16 W/°C V TJ, TSTG Junction and Storage Temperature Range -55 to + 150 °C A W Thermal Resistance Symbol Parameter e RθJA Junction-to-Ambient RθJA Junction-to-Ambient (t<10s) f Typ. Max. ––– 100 ––– 99 Units °C/W ORDERING INFORMATION: See detailed ordering and shipping information on the last page of this data sheet. Notes through are on page 10 www.irf.com 1 02/08/10 IRLML2060TRPbF Electric Characteristics @ TJ = 25°C (unless otherwise specified) Symbol V(BR)DSS Parameter Drain-to-Source Breakdown Voltage ∆V(BR)DSS/∆TJ Breakdown Voltage Temp. Coefficient RDS(on) Static Drain-to-Source On-Resistance VGS(th) Gate Threshold Voltage IDSS IGSS Drain-to-Source Leakage Current Min. Typ. Max. Units 60 ––– ––– ––– 0.06 ––– ––– 356 480 ––– 475 640 1.0 ––– 2.5 ––– ––– 20 ––– ––– 150 V Conditions VGS = 0V, ID = 250µA V/°C Reference to 25°C, ID = 5.0mA mΩ V µA VGS = 10V, ID = 1.2A VDS = VGS, ID = 25µA VDS = 60V, VGS = 0V VDS = 60V, VGS = 0V, TJ = 125°C Gate-to-Source Forward Leakage ––– ––– 100 Gate-to-Source Reverse Leakage ––– ––– -100 RG Internal Gate Resistance ––– 7.5 ––– Ω gfs Qg Forward Transconductance 1.6 ––– ––– S Total Gate Charge ––– 0.67 ––– Qgs Gate-to-Source Charge ––– 0.18 ––– Qgd Gate-to-Drain ("Miller") Charge ––– 0.40 ––– VGS = 4.5V td(on) Turn-On Delay Time ––– 4.9 ––– VDD = 30V tr Rise Time ––– 3.8 ––– td(off) Turn-Off Delay Time ––– 3.7 ––– tf Fall Time ––– 2.8 ––– Ciss Input Capacitance ––– 64 ––– Coss Output Capacitance ––– 13 ––– Crss Reverse Transfer Capacitance ––– 6.6 ––– nA d d VGS = 4.5V, ID = 0.96A VGS = 16V VGS = -16V VDS = 25V, ID = 1.2A ID = 1.2A nC ns VDS = 30V ID = 1.2A d d RG = 6.8Ω VGS = 4.5V VGS = 0V pF VDS = 25V ƒ = 1.0MHz Source - Drain Ratings and Characteristics Symbol Parameter Min. Typ. Max. Units IS Continuous Source Current ISM (Body Diode) Pulsed Source Current VSD (Body Diode) Diode Forward Voltage trr Reverse Recovery Time ––– 14 21 ns Qrr Reverse Recovery Charge ––– 8.3 12 nC 2 c ––– ––– 1.2 A ––– ––– 4.8 ––– ––– 1.2 Conditions MOSFET symbol V showing the integral reverse p-n junction diode. TJ = 25°C, IS = 1.2A, VGS = 0V TJ = 25°C, VR = 30V, IF=1.3A di/dt = 100A/µs d d www.irf.com IRLML2060TRPbF 10 10 1 BOTTOM 0.1 TOP ID, Drain-to-Source Current (A) ID, Drain-to-Source Current (A) TOP VGS 10V 8.0V 4.5V 4.0V 3.8V 3.5V 3.3V 3.0V 3.0V ≤60µs PULSE WIDTH 1 BOTTOM 3.0V 0.1 ≤60µs PULSE WIDTH Tj = 150°C Tj = 25°C 0.01 0.01 0.1 1 10 100 1000 0.1 V DS, Drain-to-Source Voltage (V) 1 10 100 1000 V DS, Drain-to-Source Voltage (V) Fig 2. Typical Output Characteristics Fig 1. Typical Output Characteristics 10 2.5 RDS(on) , Drain-to-Source On Resistance (Normalized) ID, Drain-to-Source Current (A) VGS 10V 8.0V 4.5V 4.0V 3.8V 3.5V 3.3V 3.0V T J = 150°C 1 T J = 25°C VDS = 25V ≤60µs PULSE WIDTH 0.1 ID = 1.2A VGS = 10V 2.0 1.5 1.0 0.5 2 3 4 5 VGS, Gate-to-Source Voltage (V) Fig 3. Typical Transfer Characteristics www.irf.com 6 -60 -40 -20 0 20 40 60 80 100 120 140 160 T J , Junction Temperature (°C) Fig 4. Normalized On-Resistance vs. Temperature 3 IRLML2060TRPbF 1000 14.0 VGS = 0V, f = 1 MHZ Ciss = C gs + Cgd, C ds SHORTED Crss = C gd VGS, Gate-to-Source Voltage (V) ID= 1.2A C, Capacitance (pF) Coss = Cds + Cgd 100 Ciss Coss Crss 10 12.0 VDS= 48V VDS= 30V 10.0 VDS= 12V 8.0 6.0 4.0 2.0 1 0.0 1 10 100 0.0 VDS, Drain-to-Source Voltage (V) 1.5 2.0 Fig 6. Typical Gate Charge vs. Gate-to-Source Voltage 10 100 T J = 150°C ID, Drain-to-Source Current (A) ISD, Reverse Drain Current (A) 1.0 QG, Total Gate Charge (nC) Fig 5. Typical Capacitance vs. Drain-to-Source Voltage T J = 25°C 1 OPERATION IN THIS AREA LIMITED BY R DS(on) 10 1msec 100µsec 1 10msec 0.1 T A = 25°C Tj = 150°C Single Pulse VGS = 0V 0.1 0.01 0.5 0.6 0.7 0.8 0.9 1.0 VSD, Source-to-Drain Voltage (V) Fig 7. Typical Source-Drain Diode Forward Voltage 4 0.5 1.1 0 1 10 100 VDS, Drain-to-Source Voltage (V) Fig 8. Maximum Safe Operating Area www.irf.com IRLML2060TRPbF 1.2 RD VDS ID, Drain Current (A) 1.0 VGS D.U.T. RG 0.8 + -VDD VGS 0.6 Pulse Width ≤ 1 µs Duty Factor ≤ 0.1 % 0.4 Fig 10a. Switching Time Test Circuit 0.2 VDS 90% 0.0 25 50 75 100 125 150 T A , Ambient Temperature (°C) 10% VGS Fig 9. Maximum Drain Current vs. Ambient Temperature td(on) tr t d(off) tf Fig 10b. Switching Time Waveforms Thermal Response ( Z thJA ) °C/W 1000 100 D = 0.50 0.20 0.10 0.05 0.02 0.01 10 1 0.1 Notes: 1. Duty Factor D = t1/t2 2. Peak Tj = P dm x Zthja + TA SINGLE PULSE ( THERMAL RESPONSE ) 0.01 1E-006 1E-005 0.0001 0.001 0.01 0.1 1 10 t1 , Rectangular Pulse Duration (sec) Fig 11. Typical Effective Transient Thermal Impedance, Junction-to-Ambient www.irf.com 5 IRLML2060TRPbF 2000 RDS(on), Drain-to -Source On Resistance ( mΩ) RDS(on), Drain-to -Source On Resistance (m Ω) 1000 ID = 1.2A 800 1500 T J = 125°C 600 Vgs = 10V 1000 T J = 25°C 400 200 4 5 6 7 8 9 10 Vgs = 4.5V 500 0 0 1 VGS, Gate -to -Source Voltage (V) Fig 12. Typical On-Resistance vs. Gate Voltage 2 3 4 5 ID, Drain Current (A) Fig 13. Typical On-Resistance vs. Drain Current Current Regulator Same Type as D.U.T. QG VGS QGS 50KΩ 12V .2µF .3µF QGD VG D.U.T. + V - DS VGS 3mA Charge IG ID Current Sampling Resistors Fig 14a. Basic Gate Charge Waveform 6 Fig 14b. Gate Charge Test Circuit www.irf.com IRLML2060TRPbF 100 2.6 80 ID = 250µA 2.4 2.2 Power (W) VGS(th) , Gate threshold Voltage (V) 2.8 2.0 ID = 25µA 1.8 1.6 60 40 20 1.4 1.2 0 -75 -50 -25 0 25 50 75 100 125 150 T J , Temperature ( °C ) Fig 15. Typical Threshold Voltage vs. Junction Temperature www.irf.com 1 10 100 1000 10000 100000 Time (sec) Fig 16. Typical Power vs. Time 7 IRLML2060TRPbF Micro3 (SOT-23) Package Outline Dimensions are shown in millimeters (inches) DIMENSIONS A 6 5 SYMBOL D A A1 A2 b c D E E1 e e1 L L1 L2 A A2 3 6 C E E1 1 0.15 [0.006] M C B A 2 0.10 [0.004] C A1 5 B 3X b e 0.20 [0.008] M C B A NOTES: e1 H 4 L1 Recommended Footprint c L2 0.972 0.950 0.802 3X L 7 1.900 MILLIMETERS INCHES MIN MAX MIN MAX 0.89 0.01 0.88 0.30 0.08 2.80 2.10 1.20 0.95 1.90 0.40 0.54 0.25 0 1.12 0.10 1.02 0.50 0.20 3.04 2.64 1.40 BSC BSC 0.60 REF BSC 8 0.0004 0 %6& %6& REF BSC 8 2.742 1. DIMENSIONING & TOLERANCING PER ANSI Y14.5M-1994 2. DIMENSIONS ARE SHOWN IN MILLIMETERS [INCHES]. 3. CONTROLLING DIMENSION: MILLIMETER. 4. DATUM PLANE H IS LOCATED AT THE MOLD PARTING LINE. 5. DATUM A AND B TO BE DETERMINED AT DATUM PLANE H. 6. DIMENSIONS D AND E1 ARE MEASURED AT DATUM PLANE H. DIMENSIONS DOES NOT INCLUDE MOLD PROTRUSIONS OR INTERLEAD FLASH. MOLD PROTRUSIONS OR INTERLEAD FLASH SHALL NOT EXCEED 0.25 MM [0.010 INCH] PER SIDE. 7. DIMENSION L IS THE LEAD LENGTH FOR SOLDERING TO A SUBSTRATE. 8. OUTLINE CONFORMS TO JEDEC OUTLINE TO-236 AB. Micro3 (SOT-23/TO-236AB) Part Marking Information '$7(&2'( 3$57180%(5 : ,)35(&('('%</$67',*,72)&$/(1'$5<($5 /($')5(( &X:,5( /27&2'( +$/2*(1)5(( ; 3$57180%(5&2'(5()(5(1&( $ % & ' ( ) * + , - . / 0 1 3 5 ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ ,5/0/ 1RWH$OLQHDERYHWKHZRUNZHHN DVVKRZQKHUHLQGLFDWHV/HDG)UHH <($5 < :25. :((. : $ % & ' ; < = : ,)35(&('('%<$/(77(5 <($5 < $ % & ' ( ) * + . :25. :((. : $ % & ' ; < = Note: For the most current drawing please refer to IR website at: http://www.irf.com/package/ 8 www.irf.com IRLML2060TRPbF Micro3™ Tape & Reel Information Dimensions are shown in millimeters (inches) 2.05 ( .080 ) 1.95 ( .077 ) 1.6 ( .062 ) 1.5 ( .060 ) 4.1 ( .161 ) 3.9 ( .154 ) TR FEED DIRECTION 1.85 ( .072 ) 1.65 ( .065 ) 3.55 ( .139 ) 3.45 ( .136 ) 4.1 ( .161 ) 3.9 ( .154 ) 1.32 ( .051 ) 1.12 ( .045 ) 8.3 ( .326 ) 7.9 ( .312 ) 0.35 ( .013 ) 0.25 ( .010 ) 1.1 ( .043 ) 0.9 ( .036 ) 178.00 ( 7.008 ) MAX. 9.90 ( .390 ) 8.40 ( .331 ) NOTES: 1. CONTROLLING DIMENSION : MILLIMETER. 2. OUTLINE CONFORMS TO EIA-481 & EIA-541. Note: For the most current drawing please refer to IR website at: http://www.irf.com/package/ www.irf.com 9 IRLML2060TRPbF Orderable part number Package Type IRLML2060TRPbF Micro3 Standard Pack Form Quantity Tape and Reel 3000 Note Qualification information† Cons umer Qualification level (per JE DE C JE S D47F Moisture Sensitivity Level Micro3 ††† guidelines ) MS L1 ††† (per IPC/JE DE C J-S T D-020D Yes RoHS compliant †† ) Qualification standards can be found at International Rectifier’s web site http://www.irf.com/product-info/reliability Higher qualification ratings may be available should the user have such requirements. Please contact your International Rectifier sales representative for further information: http://www.irf.com/whoto-call/salesrep/ Applicable version of JEDEC standard at the time of product release. Notes: Repetitive rating; pulse width limited by max. junction temperature. Pulse width ≤ 400µs; duty cycle ≤ 2%. Surface mounted on 1 in square Cu board. Refer to application note #AN-994. Data and specifications subject to change without notice. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7903 Visit us at www.irf.com for sales contact information. 02/2010 10 www.irf.com