FM201A RECTRON THRU SEMICONDUCTOR TECHNICAL SPECIFICATION FM207A SURFACE MOUNT GLASS PASSIVATED SILICON RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 2.0 Amperes FEATURES * * * * * * Glass passivated device Ideal for surface mounted applications Low leakage current Metallurgically bonded construction Mounting position: Any Weight: 0.057 gram DO-214AC MECHANICAL DATA * Epoxy : Device has UL flammability classification 94V-0 0.067 (1.70) 0.051 (1.29) 0.110 (2.79) 0.086 (2.18) 0.180(4.57) 0.160(4.06) 0.012 (0.305) 0.006 (0.152) 0.091 (2.31) 0.067 (1.70) 0.059 (1.50) 0.035 (0.89) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. 0.008 (0.203) 0.004 (0.102) Single phase, half wave, 60 Hz, resistive or inductive load. 0.209 (5.31) 0.185 (4.70) For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) MAXIMUM RATINGS (At T A = 25 oC unless otherwise noted) SYMBOL RATINGS FM201A FM202A FM203A FM204A FM205A FM206A FM207A UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TA = 75 oC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermaesistance Typical Junction Capacitance (Note 1) Operating and Storage Temperature Range IO 2.0 Amps I FSM 50 Amps (Note 2)Rθ JL 20 0 C/ W (Note 3)Rθ JA 50 0 C/ W CJ 30 T J, T STG -55 to + 150 SYMBOL FM201A FM202A FM203A FM204A FM205A FM206A FM207A VF 1.1 Volts 5.0 uAmps 125 uAmps pF 0 C ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 2.0A DC Maximum Average Reverse Current @T A = 25 o C at Rated DC Blocking Voltage @T A = 125 o C IR NOTES : 1. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 2. Thermal resistance junction to terminal, 5X5mm 2 copper pads to each terminal. 3. Thermal resistance junction to ambient, 5X5mm2 copper pads to each terminal. UNITS 2002-6 FIG. 1 - TYPICAL FORWARD CURRENT DERATING CURVE 2.0 1.5 1.0 Single Phase Half Wave 60Hz Resistive or Inductive Load .5 0 FIG. 3 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 100 8.3ms Single Half Sine-Wave (JEDED Method) 80 60 40 20 0 1 20 10 4 2 1.0 .4 .2 .1 2 4 6 8 10 20 40 60 80 100 NUMBER OF CYCLES AT 60Hz TJ = 25 Pulse Width=300uS 1% Duty Cycle .04 .02 .01 .6 25 50 75 100 125 150 175 AMBIENT TEMPERATURE, ( ) INSTANTANEOUS REVERSE CURRENT, (uA) 0 PEAK FORWARD SURGE CURRENT, (A) FIG. 2 - TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS INSTANTANEOUS FORWARD CURRENT, (A) 2.5 .8 1.0 1.2 1.4 1.5 INSTANTANEOUS FORWARD VOLTAGE, (V) FIG. 4 - TYPICAL REVERSE CHARACTERISTICS 10 4 TJ = 100 1.0 .4 .1 .04 TJ = 25 .01 0 20 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) FIG. 5 - TYPICAL JUNCTION CAPACITANCE JUNCTION CAPACITANCE, (pF) AVERAGE FORWARD CURRENT, (A) RATING AND CHARACTERISTIC CURVES ( FM201A THRU FM207A ) 200 100 60 40 20 10 6 4 TJ = 25 2 1 .1 .2 .4 1.0 2 4 10 20 40 100 REVERSE VOLTAGE, ( V ) RECTRON Mounting Pad Layout 0.094 MAX. (2.38 MAX.) 0.060 MIN. (1.52 MIN.) 0.052 MIN. (1.32 MIN.) 0.220 (5.58) REF Dimensions in inches and (millimeters) RECTRON