Features Applications ■ Radial Leaded Devices High ability to withstand lightning surges Ideal lightning surge coordination device Binned and sorted narrow resistance ranges available Lead free option available ■ Agency recognition: ■ ■ ■ ■ ■ ■ ■ Customer Premise Equipment (CPE) Central Office / Telecom Centers (CO) Access equipment T V Rheinland MF-R/250 Series - Telecom PTC Resettable Fuses Electrical Characteristics Model Max. Operating Voltage Max. Interrupt Ratings Volts Amps (Vrms) (A) Max. Max. Hold Current Amps at 23 °C IH 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 10.0 0.08 0.08 0.11 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.145 0.145 0.145 0.145 0.18 (Vdc) MF-R008/250U MF-R008/250 MF-R011/250U MF-R012/250 MF-R012/250-A MF-R012/250-C MF-R012/250-F MF-R012/250-1 MF-R012/250-2 MF-R012/250U MF-R014/250 MF-R014/250-A MF-R014/250-B MF-R014/250U MF-R018/250U 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Initial Resistance Ohms Ohms at at 23 °C 23 °C Min. Max. 14.0 15.0 5.0 4.0 7.0 5.5 6.0 6.0 8.0 6.0 3.0 3.0 4.5 3.5 0.8 One Hour Post-Trip Resistance Ohms at 23 °C Max. 20.0 22.0 9.0 8.0 9.0 7.5 10.5 9.0 10.5 10.0 6.0 5.5 6.0 6.5 2.0 “U” suffix indicates product without insulation coating. Environmental Characteristics Operating/Storage Temperature ..............................-40 °C to +85 °C Maximum Device Surface Temperature in Tripped State......................................................125 °C Passive Aging ..........................................................+85 °C, 1000 hours ........................................................±15 % typical resistance change +60°C, 1000 hours ±15 % typical resistance change Humidity Aging ........................................................+85 °C, 85 % R.H. 500 hours ..........................................±15 % typical resistance change Thermal Shock ........................................................MIL-STD-202F, Method 107G, ........................................±10 % typical resistance change +125 °C to -55 °C,10 times ±15 % typical resistance change Solvent Resistance ..................................................MIL-STD-202, Method 215B............................................No change Lead Solderability ....................................................ANSI/J-STD-002 ..............................................................>95 % coverage Flammability ............................................................IEC 695-2-2......................................................................No Flame for 60 secs. Vibration ..................................................................MIL-STD-883C, Method 2007.1, Condition A..................±5 % typical resistance change Test Procedures And Requirements For Model MF-R/250 Series Test Test Conditions Accept/Reject Criteria Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ R1max Time to Trip ........................................................5 times Ihold, Vmax, 23 °C..........................T ≤ typical time to trip (seconds) Hold Current ......................................................30 min. at Ihold............................................No trip Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning UL File Number ..................................................E 174545S CSA File Number ................................................CA 110338 TÜV File Number ................................................R02057213 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. 33.0 33.0 16.0 16.0 16.0 14.0 16.0 16.0 16.0 16.0 12.0 12.0 14.0 12.0 4.0 Additional Features ■ ■ Assists equipment with meeting ITU-T K.20/K.21/K.45 Assists equipment with meeting Telcordia GR-1089-C Intrabuilding MF-R/250 Series - Telecom PTC Resettable Fuses Thermal Derating Chart - Ihold (Amps) Ambient Operating Temperature Model -40 ˚C 0.124 0.171 0.186 0.255 0.269 MF-R008/250 MF-R011/250U MF-R012/250 MF-R014/250 MF-R018/250U -20 ˚C 0.110 0.151 0.165 0.199 0.240 0 ˚C 0.095 0.131 0.143 0.172 0.211 23 ˚C 0.080 0.110 0.120 0.145 0.180 40 ˚C 0.066 0.091 0.099 0.119 0.153 50 ˚C 0.059 0.081 0.088 0.106 0.138 60 ˚C 0.051 0.071 0.077 0.093 0.123 70 ˚C 0.044 0.061 0.066 0.080 0.109 85 ˚C 0.033 0.046 0.050 0.060 0.087 Itrip is approximately two times Ihold. Product Dimensions A Max. 7.5 (0.295) 6.2 (0.244) 6.2 (0.244) 7.5 (0.295) 6.2 (0.244) 7.5 (0.295) 6.2 (0.244) 10.4 (0.409) Model MF-R008/250 MF-R008/250U MF-R011/250U MF-R012/250 MF-R012/250U MF-R014/250 MF-R014/250U MF-R018/250U Packaging options: BULK: 500 pcs. per bag. B Max. 11.5 (0.453) 11.5 (0.453) 11.5 (0.453) 11.5 (0.453) 11.5 (0.453) 11.5 (0.453) 11.5 (0.453) 12.6 (0.496) C Max. 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) 5.1 ± 0.7 (0.201 ± 0.028) D Min. 5.0 (0.197) 5.0 (0.197) 5.0 (0.197) 5.0 (0.197) 5.0 (0.197) 5.0 (0.197) 5.0 (0.197) 5.0 (0.197) E Max. 4.8 (0.189) 3.8 (0.150) 3.8 (0.150) 4.8 (0.189) 3.8 (0.150) 4.8 (0.189) 3.8 (0.150) 3.8 (0.150) Physical Characteristics Lead Dia. Material 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) 0.65 Sn/Cu (0.026) DIMENSIONS = TAPE & REEL: 1500 pcs. per reel (not available with binned option). A E MM (INCHES) Typical Part Marking Represents total content. Layout may vary. B PART IDENTIFICATION DATE CODE (FIRST DIGIT = LAST DIGIT OF YEAR; NEXT THREE DIGITS = DAY OF YEAR) D MANUFACTURER'S TRADEMARK R012 0180T COUNTRY OF MANUFACTURE (T = TAIWAN S = CHINA) C Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. MF-R/250 Series - Telecom PTC Resettable Fuses How to Order Typical Time to Trip at 23 ˚C MF - R 012/250 U - A 05 - 2 - 99 1000 Multifuse® Product Designator 100 Hold Current, Ihold 008-018 (0.08 - 0.18 Amps) Max. Interrupt Voltage, V 250 (250 Volts) Telecom Options U = Uncoated (radial parts only) T = Pre-tripped Resistance Sorted Narrow resistance ranges Resistance Bins of 0.5 ohms 05 = 0.5 ohms Packaging Options - 0 = Bulk Packaging - 2 = Tape and Reel* (not available with binned option) Time to Trip (Seconds) Series R = Radial Leaded Component 10 MF-R018/250U 1 MF-R014/250 & MF-R014/250U MF-R012/250 & MF-R012/250U 0.10 MF-R011/250U MF-R008/250 & MF-R008/250U 0.01 0 0.2 0.4 0.6 *Packaged per EIA486-B 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Fault Current (Amps) Lead Free Option __ = Standard Product - 99 = Lead Free Resistance Options Model MF-R012/250 MF-R012/250-A05 MF-R012/250-C05 MF-R012/250-F05 MF-R012/250-105 MF-R012/250-205 MF-R012/250U MF-R014/250 MF-R014/250-A05 MF-R014/250-B05 MF-R014/250U MF-R/250, REV. E, 02/04 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. Rmin. 4.0 7.0 5.5 6.0 6.0 8.0 6.0 3.0 3.0 4.5 3.5 Rmax. 8.0 9.0 7.5 10.5 9.0 10.5 10.0 6.0 5.5 6.0 6.5 R1Max. 16.0 16.0 14.0 16.0 16.0 16.0 16.0 12.0 12.0 12.0 12.0 Bin 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 MF-R, MF-RX, MF-R/90, MF-R/250, MF-RX/250 & MF-R/600 Series Tape and Reel Specifications Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details. Dimension Description IEC Mark EIA Mark Carrier tape width W W Hold down tape width: MF-R/600 W4 Hold down tape width: all others W4 Hold down tape W0 Top distance between tape edges W2 Dimensions Dimensions Tolerance 18 (.709) 5 (.197) 11 (.433) Lead protrusion I1 Protrusion of cutout L L Protrusion beyond hold tape I2 I2 Not specified Sprocket hole pitch P0 P0 12.7 (0.5) W6 Sprocket hole position W1 W5 Sprocket hole diameter D0 D0 Abscissa to plane (straight lead) H H Abscissa to plane (kinked lead) H0 H0 Abscissa to top H1 H1 Overall width w/lead protrusion C1 Overall width w/o lead protrusion C2 L1 Pitch tolerance 20 consecutive Device pitch: MF-R005 – MF-R160 & MF-R/90 Device pitch: MF-R185 – MF-R400 & MF-R/600 Device pitch: MF-RX110 – MF-RX160 Device pitch: MF-RX185 – MF-RX375 Device pitch: MF-R/250 & MF-RX/250 t t t1 Tape thickness with splice Splice sprocket hole alignment 12.7 (0.5) 25.4 (1.0) 12.7 (0.5) 12.7 (0.5) 12.7 (0.5) 0.9 (.035) 2.0 (.079) 0 Body lateral deviation ∆h ∆h Body tape plane deviation ∆p ∆p 0 3.81 (.015) Lead seating plane deviation: MF-R/600* ∆P1 P1 Lead seating plane deviation ∆P1 P1 Lead spacing F F Reel width w w Reel diameter d a Space between flanges less device *Differs from EIA specification. Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. min. ref. No protrusion 3 (.118) 9 (.354) 4 (.157) 18.5 (.728) 16 (.63) 32.2 (1.268) 43.2 (1.7) 42.5 (1.673) 1.0 (.039) 11 (.433) Tape thickness -0.5/+1.0 (-0.02/+.039) 0 0 5.08 (0.2) 56 (2.205) 370 (14.57) 4.75 (.187) max. -0.5/+0.75 (-0.02/+0.03) ±0.2 (±.0078) ±3.0 (±.118) ±0.5 (±.02) max. max. max. max. max. ±0.3 (±.012) ±1 max. max. ±0.3 (±.012) ±1.0 (±.039) ±1.3 (±.051) ±0.7 (±.028) ±0.7 (±.028) ±0.8 (±.035) max. max. ±3.25 (±.128) DIMENSIONS = MM (INCHES) MF-R, MF-RX, MF-R/90, MF-R/250, MF-RX/250 & MF-R/600 Series Tape and Reel Specifications IEC Mark Dimension Description EIA Mark Dimensions Dimensions Tolerance Space between flanges less device Arbor hole diameter f c Core diameter: MF-R, MF-RX, MF-R/90 & MF-R/250 h n Core diameter: MF-RX/250 & MF-R/600 h n 4.75 (.187) 26 (1.024) ±3.25 (±.128) ±12.0 (±.472) 80 (3.15) max. 91 (3.58) 372 (14.6) 372 (14.6) 372 (14.6) 56 (2.2) 67 (2.64) 64 (2.52) Box: MF-R, MF-RX, MF-R/90 & MF-R/250 Box: MF-RX/250 Box: MF-R/600 max. 372 (14.6) 362 (14.25) 362 (14.25) max. max. max. Consecutive missing places: MF-R, MF-RX, MF-R/90 & MF-R/250 3 Consecutive missing places: MF-RX/250 & MF-R/600 max. None Empty places per reel: MF-R, MF-RX, MF-R/90 & MF-R/250 Not specified Empty places per reel: MF-RX/250 & MF-R/600 0.1 % Taped Component Dimensions - Figure 1 ∆p ∆h ∆h ∆p Reference plane P1 H1 A L I2 H1 F H H0 B W0 I1 P0 D0 DIMENSIONS = MM (INCHES) W1 W User direction of feed Cross section A - B Reel Dimensions - Figure 2 t Reel h d User direction of feed Upper side Tape Lower side f h w Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.