VISHAY RGP20J

RGP20A THRU RGP20J
GLASS PASSIVATED JUNCTION FAST SWITCHING PLASTIC RECTIFIER
Forward Current - 2.0 Amperes
*
Reverse Voltage - 50 to 600 Volts
D
FEATURES
Case Style GP20
P
A
T
E
N
T
E
♦ Plastic package
has Underwriters Laboratory
Flammability Classification 94V-0
♦ High temperature metallurgically
bonded construction
♦ Glass passivated cavity-free junction
♦ Capable of meeting environmental standards of
MIL-S-19500
♦ Fast switching for high efficiency
♦ 2.0 Ampere operation at TA=55°C with no thermal
runaway
♦ Typical IR less than 0.2µA
♦ High temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
1.0 (25.4)
MIN.
0.210 (5.3)
0.190 (4.8)
DIA.
0.375 (9.5)
0.285 (7.2)
1.0 (25.4)
MIN.
0.042 (1.07)
0.037 (0.94)
DIA.
MECHANICAL DATA
Dimensions in inches and (millimeters)
*Glass-plastic encapsulation technique is covered by
Patent No. 3,996,602 and brazed-lead assembly by Patent No. 3,930,306
®
Case: Molded plastic over solid glass body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.03 ounce, 0.8 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
RGP
20A
RGP
20B
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
Volts
Maximum DC blocking voltage
VDC
50
100
200
400
600
Volts
Maximum average forward rectified current
0.375" (9.5mm) lead length at TA=55°C
I(AV)
2.0
Amps
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method)
IFSM
80.0
Amps
VF
1.3
Volts
IR
5.0
100.0
µA
IR(AV)
100.0
µA
trr
150.0
Maximum instantaneous forward voltage at 2.0A
Maximum DC reverse current
at rated DC blocking voltage
TA=25°C
TA=125°C
Maximum full load reverse current, full cycle
average, 0.375" (9.5mm) lead length at TA=55°C
Maximum reverse recovery time (NOTE 1)
Typical junction capacitance (NOTE 2)
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
RGP
20G
RGP
20J
250
UNITS
ns
CJ
35.0
pF
RΘJA
22.0
°C/W
TJ, TSTG
-65 to +175
°C
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
(3) Thermal resistance from junction to ambient at 0.375" (9.5mm) lead length, P.C.B. mounted
4/98
RGP
20D
RATINGS AND CHARACTERISTIC CURVES RGP20A THRU RGP20J
RESISTIVE OR
INDUCTIVE LOAD
1.5
1.0
0.5
0.375" (9.5mm) LEAD LENGTH
0
0
25
50
75
100
125
150
175
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED CURRENT,
AMPERES
FIG. 1 - FORWARD CURRENT DERATING CURVE
2.0
TA=55°C
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
10
1
10
100
AMBIENT TEMPERATURE, °C
NUMBER OF CYCLES AT 60 Hz
FIG. 3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
FIG. 4 - TYPICAL REVERSE
CHARACTERISTICS
20
10
10
1
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
0.1
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
100
TJ=125°C
TJ=100°C
1
TJ=75°C
TJ=25°C
0.1
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
0.01
0
20
40
60
80
100
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, pF
100
TJ=25°C
f=1.0 MHZ
Vsig=50mVp-p
10
5
1
10
REVERSE VOLTAGE, VOLTS
100
TRANSIENT THERMAL IMPEDANCE, °C/W
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
FIG. 6 - TYPICAL TRANSIENT THERMAL IMPEDANCE
100
10
1
0.1
0.01
0.1
1
10
t, PULSE DURATION, sec.
100