ADPOW APT30DQ60KG

600V 30A
APT30DQ60K
APT30DQ60KG*
®
*G Denotes RoHS Compliant, Pb Free Terminal Finish.
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
(K)
PRODUCT APPLICATIONS
PRODUCT FEATURES
PRODUCT BENEFITS
• Anti-Parallel Diode
-Switchmode Power Supply
-Inverters
• Free Wheeling Diode
-Motor Controllers
-Converters
-Inverters
• Snubber Diode
• Ultrafast Recovery Times
• Low Losses
• Soft Recovery Characteristics
• Low Noise Switching
• Popular TO-220 Package
• Cooler Operation
• Low Forward Voltage
• Higher Reliability Systems
• Low Leakage Current
• Increased System Power
Density
• PFC
• Avalanche Energy Rated
TO-220
1
2
2
1
1 - Cathode
2 - Anode
Back of Case - Cathode
MAXIMUM RATINGS
Symbol
VR
All Ratings: TC = 25°C unless otherwise specified.
Characteristic / Test Conditions
APT30DQ60K(G)
UNIT
600
Volts
Maximum D.C. Reverse Voltage
VRRM
Maximum Peak Repetitive Reverse Voltage
VRWM
Maximum Working Peak Reverse Voltage
IF(AV)
Maximum Average Forward Current (TC = 117°C, Duty Cycle = 0.5)
30
RMS Forward Current (Square wave, 50% duty)
51
IF(RMS)
IFSM
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
EAVL
Avalanche Energy (1A, 40mH)
TJ,TSTG
TL
Amps
320
20
mJ
-55 to 175
Operating and StorageTemperature Range
°C
300
Lead Temperature for 10 Sec.
STATIC ELECTRICAL CHARACTERISTICS
Forward Voltage
IRM
Maximum Reverse Leakage Current
CT
Junction Capacitance, VR = 200V
MIN
TYP
MAX
IF = 30A
2.0
2.4
IF = 60A
2.4
IF = 30A, TJ = 125°C
1.7
VR = 600V
APT Website - http://www.advancedpower.com
Volts
25
VR = 600V, TJ = 125°C
500
36
UNIT
µA
pF
11-2005
VF
Characteristic / Test Conditions
053-4215 Rev B
Symbol
DYNAMIC CHARACTERISTICS
Symbol
APT30DQ60K(G)
Characteristic
Test Conditions
trr
Reverse Recovery Time
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM
IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IF = 30A, diF/dt = -200A/µs
VR = 400V, TC = 125°C
Maximum Reverse Recovery Current
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM
VR = 400V, TC = 25°C
Maximum Reverse Recovery Current
trr
IRRM
IF = 30A, diF/dt = -200A/µs
IF = 30A, diF/dt = -1000A/µs
VR = 400V, TC = 125°C
Maximum Reverse Recovery Current
MIN
TYP
MAX
UNIT
-
23
-
30
-
55
-
3
-
175
ns
-
485
nC
-
6
-
75
ns
-
855
nC
-
22
Amps
MIN
TYP
ns
nC
-
-
Amps
Amps
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol
RθJC
WT
Torque
Characteristic / Test Conditions
MAX
UNIT
.80
°C/W
Junction-to-Case Thermal Resistance
Package Weight
0.07
oz
1.9
g
Maximum Mounting Torque
10
lb•in
1.1
N•m
APT Reserves the right to change, without notice, the specifications and information contained herein.
0.80
D = 0.9
0.70
0.60
0.7
0.50
Note:
0.5
0.40
0.30
PDM
Z JC, THERMAL IMPEDANCE (°C/W)
θ
0.90
0.3
t2
0.20
0
10-5
t
Duty Factor D = 1/t2
Peak TJ = PDM x ZθJC + TC
SINGLE PULSE
0.1
0.05
0.10
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (seconds)
FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
11-2005
RC MODEL
053-4215 Rev B
t1
Junction
temp. (°C)
0.560
0.00230
0.240
0.284
Power
(watts)
Case temperature. (°C)
FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL
TYPICAL PERFORMANCE CURVES
80
TJ = 175°C
60
TJ = 125°C
40
TJ = -55°C
20
TJ = 25°C
0
0.5
1.0
1.5
2.0
2.5
3.0
VF, ANODE-TO-CATHODE VOLTAGE (V)
Figure 2. Forward Current vs. Forward Voltage
Qrr, REVERSE RECOVERY CHARGE
(nC)
1200
T = 125°C
J
V = 400V
R
1000
60A
800
30A
600
15A
400
200
0
0
200
400
600
800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 4. Reverse Recovery Charge vs. Current Rate of Change
30A
140
120
100
15A
80
60
40
0
200
400
600
800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE(A/µs)
Figure 3. Reverse Recovery Time vs. Current Rate of Change
25
T = 125°C
J
V = 400V
60A
R
20
30A
15
10
15A
5
0
0
200
400
600
800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 5. Reverse Recovery Current vs. Current Rate of Change
60
Qrr
Duty cycle = 0.5
T = 175°C
J
trr
1.0
160
R
0
50
trr
0.8
40
IRRM
IF(AV) (A)
Kf, DYNAMIC PARAMETERS
(Normalized to 1000A/µs)
1.2
T = 125°C
J
V = 400V
60A
180
20
IRRM, REVERSE RECOVERY CURRENT
(A)
0
APT30DQ60K(G)
200
trr, REVERSE RECOVERY TIME
(ns)
IF, FORWARD CURRENT
(A)
100
0.6
0.4
20
Qrr
0.2
0.0
30
0
25
50
75
100
125
150
TJ, JUNCTION TEMPERATURE (°C)
Figure 6. Dynamic Parameters vs. Junction Temperature
10
0
25
50
75
100
125
150
175
Case Temperature (°C)
Figure 7. Maximum Average Forward Current vs. CaseTemperature
180
160
140
120
100
11-2005
80
60
40
20
0
1
10
100 200
VR, REVERSE VOLTAGE (V)
Figure 8. Junction Capacitance vs. Reverse Voltage
053-4215 Rev B
CJ, JUNCTION CAPACITANCE
(pF)
200
APT30DQ60K(G)
Vr
diF /dt Adjust
+18V
APT30GT60BR
0V
D.U.T.
30µH
trr/Qrr
Waveform
PEARSON 2878
CURRENT
TRANSFORMER
Figure 9. Diode Test Circuit
1
IF - Forward Conduction Current
2
diF /dt - Rate of Diode Current Change Through Zero Crossing.
3
IRRM - Maximum Reverse Recovery Current.
4
trr - Reverse Recovery Time, measured from zero crossing where diode
current goes from positive to negative, to the point at which the straight
line through IRRM and 0.25 IRRM passes through zero.
5
1
4
Zero
5
0.25 IRRM
3
2
Qrr - Area Under the Curve Defined by IRRM and trr.
Figure 10, Diode Reverse Recovery Waveform and Definitions
TO-220 (K) Package Outline
e3 100% Sn
10.66 (.420)
9.66 (.380)
1.39 (.055)
0.51 (.020)
12.192 (.480)
9.912 (.390)
Cathode
4.08 (.161) Dia.
3.54 (.139)
3.42 (.135)
2.54 (.100)
0.080 (2.032)
MAX.
053-4215 Rev B
11-2005
0.50 (.020)
0.41 (.016)
2.92 (.115)
2.04 (.080)
14.73 (.580)
12.70 (.500)
5.33 (.210)
4.83 (.190)
6.85 (.270)
5.85 (.230)
3.683 (.145)
MAX.
Cathode
Anode
1.01 (.040) 2-Plcs.
.83 (.033)
4.82 (.190)
3.56 (.140)
5.33 (.210)
4.83 (.190)
1.77 (.070) 2-Plcs.
1.15 (.045)
Dimensions in Millimeters and (Inches)
APT’s products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522
5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved.