ADPOW APT30D100BHBG

1000V 2x18A
APT30D100BHB
APT30D100BHBG*
®
*G Denotes RoHS Compliant, Pb Free Terminal Finish.
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
TO
PRODUCT APPLICATIONS
PRODUCT FEATURES
PRODUCT BENEFITS
• Output Rectifiers for Switchmode
Power Supply
• Ultrafast Recovery Times
• Low Losses
• Soft Recovery Characteristics
• Low Noise Switching
• Popular TO-247 Package
• Cooler Operation
• Low Forward Voltage
• Higher Reliability Systems
• Low Leakage Current
• Increased System Power
Density
1
2
-2 4
7
3
1
3
2
1 - Cathode 1
2 - Anode 1
Cathode 2
3 - Anode 2
MAXIMUM RATINGS
Symbol
VR
All Ratings Per Leg: TC = 25°C unless otherwise specified.
Characteristic / Test Conditions
APT30D100BHB(G)
UNIT
1000
Volts
Maximum D.C. Reverse Voltage
VRRM
Maximum Peak Repetitive Reverse Voltage
VRWM
Maximum Working Peak Reverse Voltage
IF(AV)
Maximum Average Forward Current (TC = 105°C, Duty Cycle = 0.5)
18
IF(AV)
RMS Forward Current (Square wave, 50% duty)
27
IFSM
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
TJ,TSTG
TL
Amps
210
-55 to 150
Operating and StorageTemperature Range
°C
300
Lead Temperature for 10 Sec.
STATIC ELECTRICAL CHARACTERISTICS
Forward Voltage
IRM
Maximum Reverse Leakage Current
CT
Junction Capacitance, VR = 200V
MIN
TYP
MAX
IF = 30A
1.9
2.3
IF = 60A
2.2
IF = 30A, TJ = 125°C
1.7
Volts
VR = VR Rated
250
VR = VR Rated, TJ = 125°C
500
APT Website - http://www.advancedpower.com
32
UNIT
µA
pF
6-2005
VF
Characteristic / Test Conditions
050-5964 Rev A
Symbol
APT30D100BHB(G)
DYNAMIC CHARACTERISTICS
Symbol
Characteristic
Test Conditions
trr
Reverse Recovery Time
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM
IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C
Maximum Reverse Recovery Current
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM
Reverse Recovery Time
Qrr
Reverse Recovery Charge
VR = 667V, TC = 25°C
IF = 30A, diF/dt = -200A/µs
Maximum Reverse Recovery Current
trr
IRRM
IF = 30A, diF/dt = -200A/µs
VR = 667V, TC = 125°C
IF = 30A, diF/dt = -1000A/µs
Maximum Reverse Recovery Current
VR = 667V, TC = 125°C
MIN
TYP
MAX
UNIT
-
29
-
290
-
670
-
5
-
390
ns
-
2350
nC
-
11
-
160
ns
-
3500
nC
-
38
Amps
MIN
TYP
ns
nC
-
-
Amps
Amps
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol
Characteristic / Test Conditions
MAX
RθJC
Junction-to-Case Thermal Resistance
1.8
RθJA
Junction-to-Ambient Thermal Resistance
40
WT
Torque
Package Weight
oz
5.9
g
10
lb•in
1.1
N•m
APT Reserves the right to change, without notice, the specifications and information contained herein.
0.9
0.7
0.5
Note:
0.80
PDM
Z JC, THERMAL IMPEDANCE (°C/W)
θ
2.00
1.20
0.3
t
0.1
0
0.05
10-5
Duty Factor D = 1/t2
Peak TJ = PDM x ZθJC + TC
SINGLE PULSE
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (seconds)
FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
RC MODEL
6-2005
Junction
temp (°C)
050-5964 Rev A
t1
t2
0.40
Power
(watts)
0.451 °C/W
0.00273 J/°C
1.18 °C/W
0.0448 J/°C
0.164 °C/W
1.62 J/°C
Case temperature (°C)
FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL
°C/W
0.22
Maximum Mounting Torque
1.60
UNIT
TYPICAL PERFORMANCE CURVES
100
70
60
TJ = 150°C
40
30
TJ = 25°C
TJ = 125°C
20
TJ = -55°C
10
0
0
0.5
1
1.5
2
2.5
3.
VF, ANODE-TO-CATHODE VOLTAGE (V)
Figure 2. Forward Current vs. Forward Voltage
Qrr, REVERSE RECOVERY CHARGE
(nC)
6000
T = 125°C
J
V = 667V
R
5000
60A
4000
3000
30A
2000
15A
1000
0
0
200
400
600
800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 4. Reverse Recovery Charge vs. Current Rate of Change
trr
1.0
0.4
300
30A
250
15A
200
150
100
45
40
T = 125°C
J
V = 667V
R
60A
35
30
25
20
30A
15
15A
10
5
0
0
200
400
600
800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 5. Reverse Recovery Current vs. Current Rate of Change
35
Duty cycle = 0.5
T = 175°C
J
30
25
Qrr
0.2
0.0
R
0
200
400
600
800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE(A/µs)
Figure 3. Reverse Recovery Time vs. Current Rate of Change
Qrr
trr
0.6
350
0
IRRM
0.8
T = 125°C
J
V = 667V
60A
50
IF(AV) (A)
Kf, DYNAMIC PARAMETERS
(Normalized to 1000A/µs)
1.2
trr, REVERSE RECOVERY TIME
(ns)
80
IRRM, REVERSE RECOVERY CURRENT
(A)
IF, FORWARD CURRENT
(A)
90
50
APT30D100BHB(G)
400
20
15
10
5
0
25
50
75
100
125
150
TJ, JUNCTION TEMPERATURE (°C)
Figure 6. Dynamic Parameters vs. Junction Temperature
0
25
50
75
100
125
150
175
Case Temperature (°C)
Figure 7. Maximum Average Forward Current vs. CaseTemperature
250
200
6-2005
150
100
50
0
1
10
100 200
VR, REVERSE VOLTAGE (V)
Figure 8. Junction Capacitance vs. Reverse Voltage
050-5964 Rev A
CJ, JUNCTION CAPACITANCE
(pF)
300
APT30D100BHB(G)
Vr
diF /dt Adjust
+18V
APT10035LLL
0V
D.U.T.
30µH
trr/Qrr
Waveform
PEARSON 2878
CURRENT
TRANSFORMER
Figure 9. Diode Test Circuit
1
IF - Forward Conduction Current
2
diF /dt - Rate of Diode Current Change Through Zero Crossing.
3
IRRM - Maximum Reverse Recovery Current.
4
trr - Reverse Recovery Time, measured from zero crossing where diode
current goes from positive to negative, to the point at which the straight
line through IRRM and 0.25 IRRM passes through zero.
5
1
4
Zero
5
3
2
Qrr - Area Under the Curve Defined by IRRM and trr.
Figure 10, Diode Reverse Recovery Waveform and Definitions
TO-247 Package Outline
e1 SAC: Tin, Silver, Copper
4.69 (.185)
5.31 (.209)
1.49 (.059)
2.49 (.098)
15.49 (.610)
16.26 (.640)
6.15 (.242) BSC
Anode 1 / Cathode 2
20.80 (.819)
21.46 (.845)
3.55 (.140)
3.81 (.150)
4.50 (.177) Max.
6-2005
0.40 (.016)
0.79 (.031)
050-5964 Rev A
5.38 (.212)
6.20 (.244)
2.21 (.087)
2.59 (.102)
19.81 (.780)
20.32 (.800)
2.87 (.113)
3.12 (.123)
1.65 (.065)
2.13 (.084)
1.01 (.040)
1.40 (.055)
Cathode 1
Anode 1 / Cathode 2
Anode 2
5.45 (.215) BSC
2-Plcs.
Dimensions in Millimeters and (Inches)
APT’s products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522
5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved.
0.25 IRRM