1000V 2x18A APT30D100BHB APT30D100BHBG* ® *G Denotes RoHS Compliant, Pb Free Terminal Finish. ULTRAFAST SOFT RECOVERY RECTIFIER DIODE TO PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS • Output Rectifiers for Switchmode Power Supply • Ultrafast Recovery Times • Low Losses • Soft Recovery Characteristics • Low Noise Switching • Popular TO-247 Package • Cooler Operation • Low Forward Voltage • Higher Reliability Systems • Low Leakage Current • Increased System Power Density 1 2 -2 4 7 3 1 3 2 1 - Cathode 1 2 - Anode 1 Cathode 2 3 - Anode 2 MAXIMUM RATINGS Symbol VR All Ratings Per Leg: TC = 25°C unless otherwise specified. Characteristic / Test Conditions APT30D100BHB(G) UNIT 1000 Volts Maximum D.C. Reverse Voltage VRRM Maximum Peak Repetitive Reverse Voltage VRWM Maximum Working Peak Reverse Voltage IF(AV) Maximum Average Forward Current (TC = 105°C, Duty Cycle = 0.5) 18 IF(AV) RMS Forward Current (Square wave, 50% duty) 27 IFSM Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms) TJ,TSTG TL Amps 210 -55 to 150 Operating and StorageTemperature Range °C 300 Lead Temperature for 10 Sec. STATIC ELECTRICAL CHARACTERISTICS Forward Voltage IRM Maximum Reverse Leakage Current CT Junction Capacitance, VR = 200V MIN TYP MAX IF = 30A 1.9 2.3 IF = 60A 2.2 IF = 30A, TJ = 125°C 1.7 Volts VR = VR Rated 250 VR = VR Rated, TJ = 125°C 500 APT Website - http://www.advancedpower.com 32 UNIT µA pF 6-2005 VF Characteristic / Test Conditions 050-5964 Rev A Symbol APT30D100BHB(G) DYNAMIC CHARACTERISTICS Symbol Characteristic Test Conditions trr Reverse Recovery Time trr Reverse Recovery Time Qrr Reverse Recovery Charge IRRM IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr Reverse Recovery Charge IRRM Reverse Recovery Time Qrr Reverse Recovery Charge VR = 667V, TC = 25°C IF = 30A, diF/dt = -200A/µs Maximum Reverse Recovery Current trr IRRM IF = 30A, diF/dt = -200A/µs VR = 667V, TC = 125°C IF = 30A, diF/dt = -1000A/µs Maximum Reverse Recovery Current VR = 667V, TC = 125°C MIN TYP MAX UNIT - 29 - 290 - 670 - 5 - 390 ns - 2350 nC - 11 - 160 ns - 3500 nC - 38 Amps MIN TYP ns nC - - Amps Amps THERMAL AND MECHANICAL CHARACTERISTICS Symbol Characteristic / Test Conditions MAX RθJC Junction-to-Case Thermal Resistance 1.8 RθJA Junction-to-Ambient Thermal Resistance 40 WT Torque Package Weight oz 5.9 g 10 lb•in 1.1 N•m APT Reserves the right to change, without notice, the specifications and information contained herein. 0.9 0.7 0.5 Note: 0.80 PDM Z JC, THERMAL IMPEDANCE (°C/W) θ 2.00 1.20 0.3 t 0.1 0 0.05 10-5 Duty Factor D = 1/t2 Peak TJ = PDM x ZθJC + TC SINGLE PULSE 10-4 10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (seconds) FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION RC MODEL 6-2005 Junction temp (°C) 050-5964 Rev A t1 t2 0.40 Power (watts) 0.451 °C/W 0.00273 J/°C 1.18 °C/W 0.0448 J/°C 0.164 °C/W 1.62 J/°C Case temperature (°C) FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL °C/W 0.22 Maximum Mounting Torque 1.60 UNIT TYPICAL PERFORMANCE CURVES 100 70 60 TJ = 150°C 40 30 TJ = 25°C TJ = 125°C 20 TJ = -55°C 10 0 0 0.5 1 1.5 2 2.5 3. VF, ANODE-TO-CATHODE VOLTAGE (V) Figure 2. Forward Current vs. Forward Voltage Qrr, REVERSE RECOVERY CHARGE (nC) 6000 T = 125°C J V = 667V R 5000 60A 4000 3000 30A 2000 15A 1000 0 0 200 400 600 800 1000 1200 -diF /dt, CURRENT RATE OF CHANGE (A/µs) Figure 4. Reverse Recovery Charge vs. Current Rate of Change trr 1.0 0.4 300 30A 250 15A 200 150 100 45 40 T = 125°C J V = 667V R 60A 35 30 25 20 30A 15 15A 10 5 0 0 200 400 600 800 1000 1200 -diF /dt, CURRENT RATE OF CHANGE (A/µs) Figure 5. Reverse Recovery Current vs. Current Rate of Change 35 Duty cycle = 0.5 T = 175°C J 30 25 Qrr 0.2 0.0 R 0 200 400 600 800 1000 1200 -diF /dt, CURRENT RATE OF CHANGE(A/µs) Figure 3. Reverse Recovery Time vs. Current Rate of Change Qrr trr 0.6 350 0 IRRM 0.8 T = 125°C J V = 667V 60A 50 IF(AV) (A) Kf, DYNAMIC PARAMETERS (Normalized to 1000A/µs) 1.2 trr, REVERSE RECOVERY TIME (ns) 80 IRRM, REVERSE RECOVERY CURRENT (A) IF, FORWARD CURRENT (A) 90 50 APT30D100BHB(G) 400 20 15 10 5 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) Figure 6. Dynamic Parameters vs. Junction Temperature 0 25 50 75 100 125 150 175 Case Temperature (°C) Figure 7. Maximum Average Forward Current vs. CaseTemperature 250 200 6-2005 150 100 50 0 1 10 100 200 VR, REVERSE VOLTAGE (V) Figure 8. Junction Capacitance vs. Reverse Voltage 050-5964 Rev A CJ, JUNCTION CAPACITANCE (pF) 300 APT30D100BHB(G) Vr diF /dt Adjust +18V APT10035LLL 0V D.U.T. 30µH trr/Qrr Waveform PEARSON 2878 CURRENT TRANSFORMER Figure 9. Diode Test Circuit 1 IF - Forward Conduction Current 2 diF /dt - Rate of Diode Current Change Through Zero Crossing. 3 IRRM - Maximum Reverse Recovery Current. 4 trr - Reverse Recovery Time, measured from zero crossing where diode current goes from positive to negative, to the point at which the straight line through IRRM and 0.25 IRRM passes through zero. 5 1 4 Zero 5 3 2 Qrr - Area Under the Curve Defined by IRRM and trr. Figure 10, Diode Reverse Recovery Waveform and Definitions TO-247 Package Outline e1 SAC: Tin, Silver, Copper 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) 15.49 (.610) 16.26 (.640) 6.15 (.242) BSC Anode 1 / Cathode 2 20.80 (.819) 21.46 (.845) 3.55 (.140) 3.81 (.150) 4.50 (.177) Max. 6-2005 0.40 (.016) 0.79 (.031) 050-5964 Rev A 5.38 (.212) 6.20 (.244) 2.21 (.087) 2.59 (.102) 19.81 (.780) 20.32 (.800) 2.87 (.113) 3.12 (.123) 1.65 (.065) 2.13 (.084) 1.01 (.040) 1.40 (.055) Cathode 1 Anode 1 / Cathode 2 Anode 2 5.45 (.215) BSC 2-Plcs. Dimensions in Millimeters and (Inches) APT’s products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved. 0.25 IRRM