VISHAY BA892V-04W

BA892V-04W
Vishay Semiconductors
Band Switching Diodes - Dual, Series in SOT-323
Description
The main purpose of the BA892V-04W is the Band
Switching. Biased with a DC forward current for signals at frequencies over 100 MHz up to 3 GHz this
diode behaves like a current controlled resistor and
not as a diode any more.
Depending on the forward current the forward resistance rf can be switched far below 1 Ω, so that the
Switch is closed.
To open the Switch, the BA892V-04W has to be
driven in the reverse mode where the BA892V-04W
behaves like a small capacitor with high isolation.
So typical applications for this Band Switching Diode
are mobile and TV-applications.
Features
•
•
•
•
Low forward resistance
Small reverse capacitance
Lead (Pb)-free component
Component in accordance to
RoHS 2002/95/EC and WEEE 2002/96/EC
2
3
1
1
2
18379
3
Applications
Band switching up to 3 GHz
Low loss band-switching in TV/VTR tuners
Mechanical Data
e3
Case: SOT-323 Plastic case
Weight: approx. 6.0 mg
Packaging Codes/Options:
GS08 / 3 k per 7" reel (8 mm tape), 3 k/box
Parts Table
Part
BA892V-04W
Ordering code
BA892V-04W-GS08
Marking
AW4
Remarks
Tape and Reel
Absolute Maximum Ratings
Tamb = 25 °C, unless otherwise specified
Symbol
Value
Reverse voltage
Parameter
Test condition
VR
35
V
Forward current
IF
100
mA
Junction temperature
Storage temperature range
Unit
Tj
150
°C
Tstg
-55 to +150
°C
Symbol
Value
Unit
RthJS
100
K/W
Thermal Characteristics
Tamb = 25 °C, unless otherwise specified
Parameter
Junction soldering point
Document Number 85649
Rev. 1.2, 24-Jun-05
Test condition
www.vishay.com
1
BA892V-04W
Vishay Semiconductors
Electrical Characteristics
Tamb = 25 °C, unless otherwise specified
Symbol
Min
Reverse voltage
Parameter
IR = 10 µA
Test condition
VR
35
Reverse current
VR = 20 V
IR
Typ.
Max
Unit
20
nA
V
Forward voltage
IF = 100 mA
VF
Diode capacitance
f = 1 MHz, VR = 0
CD
f = 1 MHz, VR = 1 V
CD
0.9
1.2
pF
f = 1 MHz, VR = 3 V
CD
0.85
1.1
pF
f = 100 MHz, IF = 1 mA
rf
0.6
f = 100 MHz, IF = 3 mA
rf
0.45
0.7
f = 100 MHz, IF = 10 mA
rf
0.34
0.5
IF = 10 mA, IR = 6 mA, iR = 3 mA
trr
90
Forward resistance
Charge carrier life time
1.1
1.1
V
pF
Ω
Ω
Ω
ns
Typical Characteristics (Tamb = 25 °C unless otherwise specified)
I F - Forward Current ( mA )
100.00
10.00
1.00
0.10
0.01
0.5
IF - Forward Current (mA)
Figure 1. Forward Resistance vs. Forward Current
0.8
0.9
1.0
70
f = 1 MHz
VR - Reverse Voltage ( V )
CD - Diode Capacitance ( pF )
0.7
Figure 3. Forward Current vs. Forward Voltage
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
4
8
12
16
20
24
Figure 2. Diode Capacitance vs. Reverse Voltage
www.vishay.com
60
50
40
30
20
10
0
0.01
28
VR - Reverse V oltage (V)
18332
2
0.6
VF - Forward Voltage ( V )
18324
18328
0.1
1.0
10
100
1000
IR - Reverse Current ( µA )
Figure 4. Reverse Voltage vs. Reverse Current
Document Number 85649
Rev. 1.2, 24-Jun-05
BA892V-04W
Vishay Semiconductors
12
I F - Forward Current ( mA )
10
IF = 10 mA
IR = 6 mA
i rr = 3 mA
8
6
4
2
0
-2
-4
-6
-8
-50
0
50
100
150
200
Recovery Time ( ns )
18336
Figure 5. Typical Charge Recovery Curve
Package Dimensions in mm (Inches)
0.10 (0.004)
1.00 (0.039)
0.10 (0.004)
SO Method E
10
Mounting Pad Layout
2.05 (0.080)
0.39 (0.015)
2.0 (0.079)
0.95 (0.37)
0.30 (0.012)
1.3 (0.051)
Document Number 85649
Rev. 1.2, 24-Jun-05
2.00 (0.078)
1.25 (0.049)
0.9 (0.035)
0.95 (0.037)
96 12236
www.vishay.com
3
BA892V-04W
Vishay Semiconductors
Ozone Depleting Substances Policy Statement
It is the policy of Vishay Semiconductor GmbH to
1. Meet all present and future national and international statutory requirements.
2. Regularly and continuously improve the performance of our products, processes, distribution and operating
systems with respect to their impact on the health and safety of our employees and the public, as well as
their impact on the environment.
It is particular concern to control or eliminate releases of those substances into the atmosphere which are
known as ozone depleting substances (ODSs).
The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs
and forbid their use within the next ten years. Various national and international initiatives are pressing for an
earlier ban on these substances.
Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use
of ODSs listed in the following documents.
1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments
respectively
2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental
Protection Agency (EPA) in the USA
3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively.
Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting
substances and do not contain such substances.
We reserve the right to make changes to improve technical design
and may do so without further notice.
Parameters can vary in different applications. All operating parameters must be validated for each
customer application by the customer. Should the buyer use Vishay Semiconductors products for any
unintended or unauthorized application, the buyer shall indemnify Vishay Semiconductors against all
claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal
damage, injury or death associated with such unintended or unauthorized use.
Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany
www.vishay.com
4
Document Number 85649
Rev. 1.2, 24-Jun-05
Legal Disclaimer Notice
Vishay
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.
Document Number: 91000
Revision: 08-Apr-05
www.vishay.com
1