EIC FBR2500

FBR2500 - FBR2510
FAST RECOVERY
BRIDGE RECTIFIERS
PRV : 50 - 1000 Volts
Io : 25 Amperes
BR50
FEATURES :
*
*
*
*
*
*
0.728(18.50)
0.688(17.40)
High case dielectric strength
High surge current capability
High reliability
Low reverse current
Low forward voltage drop
Fast switching for high efficiency
0.685(16.70) 1.130(28.70)
0.618(15.70) 1.120(28.40)
0.570(14.50)
0.530(13.40)
MECHANICAL DATA :
* Case : Molded plastic with heatsink integrally
mounted in the bridge encapsulation
* Epoxy : UL94V-O rate flame retardant
* Terminals : plated .25" (6.35 mm). Faston
* Polarity : Polarity symbols marked on case
* Mounting position : Bolt down on heat-sink with
silicone thermal compound between bridge
and mounting surface for maximum heat
transfer efficiency.
* Weight : 17.1 grams
0.210(5.30)
0.200(5.10)
0.658(16.70)
0.618(15.70)
0.032(0.81)
0.028(0.71)
0.252(6.40)
0.248(6.30)
φ 0.100(2.50)
0.090(2.30)
0.905(23.0)
0.826(21.0)
0.310(7.87)
0.280(7.11)
Metal Heatsink
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATING
SYMBOL
FBR FBR FBR FBR FBR FBR FBR
UNIT
2500 2501 2502 2504 2506 2508 2510
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
1000 Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
Maximum Average Forward Current Tc = 55 °C
IF(AV)
25
Amps.
Peak Forward Surge Current Single half sine wave
Superimposed on rated load (JEDEC Method)
IFSM
700
Volts
1000 Volts
300
Amps.
Current Squared Time at t < 8.3 ms.
2
It
375
A2S
Maximum Forward Voltage drop per Diode at IF = 12.5 Amps.
VF
1.3
Volts
IR
10
µA
Maximum DC Reverse Current
Ta = 25 °C
at Rated DC Blocking Voltage
Ta = 100 °C
Maximum Reverse Recovery Time (Note 1)
Typical Thermal Resistance per diode (Note 2)
Operating Junction Temperature Range
Storage Temperature Range
IR(H)
Trr
µA
200
150
250
500
ns
RθJC
1.45
°C/W
TJ
- 50 to + 150
°C
TSTG
- 50 to + 150
°C
Notes :
1 ) Measured with IF = 0.5 Amp., IR = 1 Amp., Irr = 0.25 Amp.
2 ) Thermal Resistance from junction to case with units mounted on a 5" x 6" x 4.9" (12.8cm.x 15.2cm.x 12.4cm.) Al.-Finned Plate.
UPDATE : APRIL 21, 1998
RATING AND CHARACTERISTIC CURVES ( FBR2500 - FBR2510 )
FIG.1 - REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
50 Ω
Trr
10 Ω
+ 0.5 A
D.U.T.
+
0
PULSE
GENERATOR
( NOTE 2 )
50 Vdc
(approx)
1Ω
- 0.25
OSCILLOSCOPE
( NOTE 1 )
- 1.0 A
SET TIME BASE FOR 50/200 ns/cm
NOTES : 1. Rise Time = 7 ns max., Input Impedance = 1 megaohm, 22 pF.
1 cm
2. Rise time = 10 ns max., Source Impedance = 50 ohms.
3. All Resistors = Non-inductive Types.
FIG.2 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
FIG.3 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
300
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
25
20
15
10
5
Tc = 55 °C
240
180
120
60
60Hz RESISTIVE OR INDUCTIVE LOAD
0
0
25
50
75
100
125
150
0
175
1
CASE TEMPERATURE, ( °C)
2
6
10
20
40
60
FIG.5 - TYPICAL REVERSE CHARACTERISTICS
PER DIODE
REVERSE CURRENT, MICROAMPERES
PER DIODE
100
10
1.0
Pulse Width = 300 µs
2% Duty Cycle
0.1
TJ = 25 °C
10
TJ = 100 °C
1.0
0.1
TJ = 25 °C
0.01
0
20
40
60
80
100
120
PERCENT OF RATED REVERSE
VOLTAGE, (%)
0.01
0
0.2
0.4
0.6
0.8
100
NUMBER OF CYCLES AT 60Hz
FIG.4 - TYPICAL FORWARD CHARACTERISTICS
FORWARD CURRENT, AMPERES
4
1.0
1.2
1.4
1.6
FORWARD VOLTAGE, VOLTS
1.8
2.0
140