FREESCALE MFR4200MPB40

MFR4200
Data Sheet
FlexRay
Communication
Controllers
MFR4200
Rev. 0
8/2005
freescale.com
MFR4200 Data Sheet
MFR4200
Rev. 0
8/2005
To provide the most up-to-date information, the revision of our documents on the World Wide Web will be
the most current. Your printed copy may be an earlier revision. To verify that you have the latest
information available, refer to http://www.freescale.com
The following revision history table summarizes changes contained in this document. For your
convenience, the page number designators have been linked to the appropriate location.
Revision History
Date
Revision
Level
08/2005
0
Description
Initial release.
Page
Number(s)
N/A
MFR4200 Data Sheet, Rev. 0
4
Freescale Semiconductor
Introduction
Device Overview
MFR4200 FlexRay Communication Controller
Dual Output Voltage Regulator (VREG3V3V2)
Clocks and Reset Generator
Oscillator (OSCV2)
Electrical Characteristics
Package Information
Printed Circuit Board Layout Recommendations
MFR4200 Protocol Implementation Document
Index of Registers
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
5
MFR4200 Data Sheet, Rev. 0
6
Freescale Semiconductor
Contents
Section Number
Title
Page
Chapter 1
Introduction
1.1
1.2
1.3
1.4
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Additional Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Part Number Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Chapter 2
Device Overview
2.1
2.2
2.3
2.4
2.5
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.1.2 Implementation Details and Constraints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.1.3 Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.1.4 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.1.5 Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.1.6 Part ID Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.2.1 System Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.2.2 Pin Functions and Signal Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.2.3 Detailed Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
2.2.4 Power Supply Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
System Clock Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.4.2 Recommended Pullup/down Resistor Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.4.3 Host Controller Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.4.4 External Output Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
2.4.5 MFR4200 Connection to FlexRay Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
2.4.6 Power Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Resets and Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
2.5.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
2.5.2 Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
2.5.3 Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
7
Section Number
Title
Page
Chapter 3
MFR4200 FlexRay Communication Controller
3.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
3.1.1 MFR4200 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
3.1.2 MFR4200 Implementation Parameters and Constraints . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.2 Memory Map and Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.2.2 Register Map Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
3.2.3 Register Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
3.3 Message Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
3.3.1 Message Buffer Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
3.3.2 Message Buffer Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
3.3.3 Message Buffer Slot Status Vector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
3.3.4 Message ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
3.3.5 NMVector Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
3.3.6 Data[0:31] — Data Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
3.4 Message Buffer Control, Configuration, Status and Filtering Register Set . . . . . . . . . . . . . . . . . 150
3.4.1 Message Buffer Control, Configuration and Status Register . . . . . . . . . . . . . . . . . . . . . 150
3.4.2 Message Buffer Filter Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
3.4.3 Receive FIFO Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
3.5 Message Buffer Handling and Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
3.5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
3.5.2 Buffer Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
3.5.3 Active Message Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
3.5.4 Buffer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
3.5.5 Buffer Reconfiguration in the Normal State of Operation . . . . . . . . . . . . . . . . . . . . . . . 172
3.5.6 Message Buffer Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
3.6 Receive FIFO Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
3.7 Host Controller Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
3.7.1 MFR4200 Asynchronous Memory Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
3.7.2 MFR4200 HCS12 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
3.8 External 4/10 MHz Output Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
3.9 Communication Controller States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
3.9.1 Hard Reset State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
3.9.2 Configuration State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
3.9.3 Diagnosis Stop State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
3.9.4 Normal Active State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
3.9.5 Normal Passive State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
3.10 Debug Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
3.10.1 Debug Port Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
3.10.2 Debug Port Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
3.10.3 Debug Port Function Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
MFR4200 Data Sheet, Rev. 0
8
Freescale Semiconductor
Section Number
Title
Page
Chapter 4
Dual Output Voltage Regulator (VREG3V3V2)
4.1
4.2
4.3
4.4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
4.1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
4.1.2 Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
4.1.3 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
External Signal Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
4.2.1 VDDR, VSSR — Regulator Power Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
4.2.2 VDDA, VSSA — Regulator Reference Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
4.2.3 VDD, VSS — Regulator Output1 (Core Logic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
4.2.4 VDDOSC, VSSOSC — Regulator Output2 (OSC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
4.2.5 VREGEN — Optional Regulator Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
4.3.1 REG — Regulator Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
4.3.2 Full-performance Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
4.3.3 POR — Power On Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
4.3.4 LVR — Low Voltage Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
4.3.5 CTRL — Regulator Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
4.4.1 Power On Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
4.4.2 Low Voltage Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Chapter 5
Clocks and Reset Generator
5.1
5.2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
5.1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
5.2.1 MFR4200 Pins Relevant to the CRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
5.2.2 Reset Generation and CLKOUT Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Chapter 6
Oscillator (OSCV2)
6.1
6.2
6.3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
6.1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
6.1.2 Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
External Signal Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
6.2.1 VDDOSC and VSSOSC — OSC Operating Voltage, OSC Ground . . . . . . . . . . . . . . . . . . 217
6.2.2 EXTAL and XTAL — Clock/Crystal Source Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
9
Section Number
Title
Page
Appendix A
Electrical Characteristics
A.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
A.1.1 Parameter Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
A.1.2 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
A.1.3 Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
A.1.4 Current Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
A.1.5 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
A.1.6 ESD Protection and Latch-up Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
A.1.7 Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
A.1.8 Power Dissipation and Thermal Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
A.1.9 I/O Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
A.1.10 Supply Currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
A.2 Voltage Regulator (VREG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
A.2.1 Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
A.2.2 Chip Power-up and Voltage Drops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
A.2.3 Output Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
A.3 Reset and Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
A.3.1 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
A.3.2 Oscillator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
A.4 AMI Interface Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
A.5 HCS12 Interface Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Appendix B
Package Information
B.1 64-pin LQFP package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Appendix C
Printed Circuit Board Layout Recommendations
Appendix C
MFR4200 Protocol Implementation Document
C.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
C.1.1 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
C.1.2 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
C.1.3 References. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
C.2 Overall Protocol State Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
C.3 Coding and Decoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
C.3.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
C.3.2 NRZ Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
C.3.3 NRZ Decoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
MFR4200 Data Sheet, Rev. 0
10
Freescale Semiconductor
Section Number
C.4
C.5
C.6
C.7
C.8
C.9
C.10
C.11
C.12
Title
Page
C.3.4 Signal Integrity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Frame Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Media Access Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Frame and Symbol Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Wakeup, Startup, and Reintegration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
C.7.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
C.7.2 Cluster Wakeup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
C.7.3 Communication Startup and Reintegration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.2 Time Representation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.3 Synchronization Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.4 Clock Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.5 Time Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.6 Correction Term Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
C.8.7 Clock Correction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
C.8.8 Sync Frame Configuration Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Controller Host Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Device Specific Power Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Bus Guardian Schedule Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
System Parameters and Configuration Constraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
C.12.1 System Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
C.12.2 Configuration Constraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Appendix D
Index of Registers
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
11
Section Number
Title
Page
MFR4200 Data Sheet, Rev. 0
12
Freescale Semiconductor
List of Figures
Figure Number
Figure 1-1.
Figure 2-1.
Figure 2-2.
Figure 2-3.
Figure 2-4.
Figure 2-5.
Figure 2-6.
Figure 2-7.
Figure 2-8.
Figure 2-9.
Figure 2-10.
Figure 3-1.
Figure 3-2.
Figure 3-3.
Figure 3-4.
Figure 3-5.
Figure 3-6.
Figure 3-7.
Figure 3-8.
Figure 3-9.
Figure 3-10.
Figure 3-11.
Figure 3-12.
Figure 3-13.
Figure 3-14.
Figure 3-15.
Figure 3-16.
Figure 3-17.
Figure 3-18.
Figure 3-19.
Figure 3-20.
Figure 3-21.
Title
Page
Order Part Number Coding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
MFR4200 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Pin Assignments for MFR4200 in 64-pin LQFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Pierce Oscillator Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
External Clock Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Clock Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
CLKOUT Generation During Power-on Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
CLKOUT Generation during Low Voltage Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
CLKOUT Generation During External Hard Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Example: Connecting a FlexRay Optical/Electrical PHY to the MFR4200. . . . . . . . . . . 50
Example: Connecting an RS485 PHY to the MFR4200. . . . . . . . . . . . . . . . . . . . . . . . . . 50
Key to Register Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Module Version Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Module Version Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Magic Number Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Module Configuration Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Module Configuration Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Host Interface Pins Drive Strength Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Physical Layer Pins Drive Strength Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Host Interface Pins Pullup/down Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Host Interface Pins Pullup/down Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Physical Layer Pins Pullup/down Enable Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Physical Layer Pins Pullup/down Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Voltage Regulator Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Bit Duration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Delay Compensation Channel A Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Delay Compensation Channel B Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Cluster Drift Damping Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Maximum Sync Frames Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Nominal Macrotick Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Microticks Per Cycle Low Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Microticks Per Cycle High Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
13
Figure Number
Figure 3-22.
Figure 3-23.
Figure 3-24.
Figure 3-25.
Figure 3-26.
Figure 3-27.
Figure 3-28.
Figure 3-29.
Figure 3-30.
Figure 3-31.
Figure 3-32.
Figure 3-33.
Figure 3-34.
Figure 3-35.
Figure 3-36.
Figure 3-37.
Figure 3-38.
Figure 3-39.
Figure 3-40.
Figure 3-41.
Figure 3-42.
Figure 3-43.
Figure 3-44.
Figure 3-45.
Figure 3-46.
Figure 3-47.
Figure 3-48.
Figure 3-49.
Figure 3-50.
Figure 3-51.
Figure 3-52.
Figure 3-53.
Figure 3-54.
Figure 3-55.
Figure 3-56.
Title
Page
Static Slot Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Number of Static Slots Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Static Payload Length Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Minislot Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Minislot Action Point Offset Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Static Slot Action Point Offset Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Latest Dynamic Transmission Start Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Maximum Payload Length Dynamic Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Symbol Window Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Network Idle Time Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Cycle Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Maximum Cycle Length Deviation Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
External Offset Correction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
External Rate Correction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
External Correction Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Maximum Offset Correction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Maximum Rate Correction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Coldstart Maximum Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Transmit Start Sequence Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Network Management Vector Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Sync Frame Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Sync Frame Header Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Bus Guardian Tick Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Delay Counter Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Debug Port Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Start of Offset Correction Cycle Time Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Idle Detection Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Symbol Window Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Wakeup Mechanism Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Wakeup Symbol TX Idle Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Wakeup Symbol TX Low Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Listen Timeout With Noise Length Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Protocol State Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Current Cycle Counter Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Current Macrotick Counter Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MFR4200 Data Sheet, Rev. 0
14
Freescale Semiconductor
Figure Number
Figure 3-57.
Figure 3-58.
Figure 3-59.
Figure 3-60.
Figure 3-61.
Figure 3-62.
Figure 3-63.
Figure 3-64.
Figure 3-65.
Figure 3-66.
Figure 3-67.
Figure 3-68.
Figure 3-69.
Figure 3-70.
Figure 3-71.
Figure 3-72.
Figure 3-73.
Figure 3-74.
Figure 3-75.
Figure 3-76.
Figure 3-77.
Figure 3-78.
Figure 3-79.
Figure 3-80.
Figure 3-81.
Figure 3-82.
Figure 3-83.
Figure 3-84.
Figure 3-85.
Figure 3-86.
Figure 3-87.
Figure 3-88.
Figure 3-89.
Figure 3-90.
Figure 3-91.
Title
Page
Offset Correction Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Rate Correction Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Global Network Management Vector n Register, n = [0:5] . . . . . . . . . . . . . . . . . . . . . . . 96
Symbol Window Status Channel A Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Symbol Window Status Channel B Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Bus Guardian Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Startup Interrupt Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Maximum Odd Cycles Without Clock Correction Fatal Register . . . . . . . . . . . . . . . . . 101
Maximum Odd Cycles Without Clock Correction Passive Register . . . . . . . . . . . . . . . 101
Channel Status Error Counter n Register, n = [0:1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Interrupt Enable Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Slot Status Selection n Register, n = [0:3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Slot Status Counter n Register, n = [0:7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Slot Status Counter Condition n Register, n = [0:7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Slot Status Counter Incrementation Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Slot Status Counter Interrupt Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Receive Buffer Interrupt Vector Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Transmit Buffer Interrupt Vector Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
CHI Error Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Clock Correction Failed Counter Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Error Handling Level Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Interrupt Status Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Startup Interrupt Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Slot Status n Register, n = [0:7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Odd Sync Frame ID n Register, n = [0:15]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Even Sync Frame ID n Register, n = [0:15] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Odd Measurement Channel A n Register, n = [0:15] . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Odd Measurement Channel B n Register, n = [0:15] . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Even Measurement Channel A n Register, n = [0:15] . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Even Measurement Channel B n Register, n = [0:15] . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Even Measurement Counter Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Odd Measurement Counter Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
FIFO Size Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Message Buffer Control, Configuration and Status n Register, n = [0:58] . . . . . . . . . . 126
Active Transmit Buffer Frame ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
15
Figure Number
Title
Page
Figure 3-92.
Figure 3-93.
Figure 3-94.
Figure 3-95.
Figure 3-96.
Figure 3-97.
Figure 3-98.
Figure 3-99.
Figure 3-100.
Figure 3-101.
Figure 3-102.
Figure 3-103.
Figure 3-104.
Figure 3-105.
Figure 3-106.
Figure 3-107.
Figure 3-108.
Figure 3-109.
Figure 3-110.
Figure 3-111.
Figure 3-112.
Figure 3-113.
Figure 3-114.
Figure 3-115.
Figure 3-116.
Figure 3-117.
Figure 3-118.
Figure 3-119.
Figure 3-120.
Figure 3-121.
Figure 3-122.
Figure 3-123.
Active Transmit Buffer Cycle Counter and Payload Length Register . . . . . . . . . . . . . . 127
Active Transmit Buffer Header CRC Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Active Transmit Buffer Data n Register, n = [0:15] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Active Transmit Buffer Message Buffer Slot Status Vector Register . . . . . . . . . . . . . . 128
Active Receive Buffer Frame ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Active Receive Buffer Cycle Counter and Payload Length Register . . . . . . . . . . . . . . . 129
Active Receive Buffer Header CRC Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Active Receive Buffer Data n Register, n = [0:15]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Active Receive Buffer Message Buffer Slot Status Vector Register . . . . . . . . . . . . . . . 131
Active FIFO Buffer Frame ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Active FIFO Buffer Cycle Counter and Payload Length Register . . . . . . . . . . . . . . . . . 132
Active FIFO Buffer Header CRC Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Active FIFO Buffer Data n Register, n = [0:15]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Active FIFO Buffer Message Buffer Slot Status Vector Register . . . . . . . . . . . . . . . . . 133
Sync Frame Acceptance Filter Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Sync Frame Acceptance Filter Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Sync Frame Rejection Filter Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Cycle Counter Filter n Register, n = [0:58] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
FIFO Acceptance Filter Message ID Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
FIFO Acceptance Filter Message ID Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
FIFO Acceptance/Rejection Filter Channel Register . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
FIFO Rejection Filter Frame ID Value Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
FIFO Rejection Filter Frame ID Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Timer Interrupt Configuration Register 0 Cycle Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Timer Interrupt Configuration Register 0 Macrotick Offset . . . . . . . . . . . . . . . . . . . . . 140
Timer Interrupt Configuration Register 1 Cycle Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Timer Interrupt Configuration Register 1 High . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Transmit Message Buffer Slot Status Vector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Receive and Receive FIFO Message Buffer Slot Status Vector. . . . . . . . . . . . . . . . . . . 147
BUFCSnR of a Receive Message Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
BUFCSnR of a Transmit Message Single Buffer for the Dynamic Segment. . . . . . . . . 150
BUFCSnR of a Host Part Transmit Message Buffer of a Double Tx Buffer
for the Dynamic Segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Figure 3-124. BUFCSnR of a Host Part Transmit Message Buffer of a Double Tx Buffer
for the Static Segment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
MFR4200 Data Sheet, Rev. 0
16
Freescale Semiconductor
Figure Number
Title
Page
Figure 3-125. BUFCSnR of a Single Transmit Message Buffer for the Static Segment . . . . . . . . . . . 151
Figure 3-126. BUFCSnR of a CC Part Transmit Message Buffer of a Double Tx Buffer
for Dynamic and Static Segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Figure 3-127. BUFCSnR of FIFO Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Figure 3-128. CCFnR, Transmit and Receive Message Buffer Filter Registers . . . . . . . . . . . . . . . . . . 158
Figure 3-129. CCFnR, CC Part Buffer of a Double Transmit Message Buffer Filter Registers. . . . . . 158
Figure 3-130. CCFnR, FIFO Buffer Filter Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Figure 3-131. Buffer Control, Configuration, Status/Filtering Register Set for Transmit/Receive
Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Figure 3-132. Buffer Control, Configuration, Status/Filtering Register Set for Receive FIFO Buffers 163
Figure 3-133. Buffer Busy Bit Timing for a Transmit Message Buffer . . . . . . . . . . . . . . . . . . . . . . . . 165
Figure 3-134. Example of a Buffer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Figure 3-135. Transition Scheme Between Different Buffer Types Depending on Operational
Mode of CC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Figure 3-136. Operations During a Frame Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Figure 3-137. Operations with a Single Transmit Message Buffer during an Event Type of
Transmission for a Static Segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Figure 3-138. Double Transmit Message Buffer Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Figure 3-139. Doubled Buffer Data Collection with State Driven Transmit Operation . . . . . . . . . . . . 184
Figure 3-140. Doubled Buffer Data collection with Event Driven Transmit Operation . . . . . . . . . . . . 185
Figure 3-141. FIFO Status (Empty, Not Empty, Overrun) — Example of FIFO with Three
Message Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Figure 3-142. Connecting MFR4200 to MPC5xx Using the AMI (Example) . . . . . . . . . . . . . . . . . . . 190
Figure 3-143. Connecting MFR4200 to MAC71xx Using the AMI (Example) . . . . . . . . . . . . . . . . . . 191
Figure 3-144. Connecting MFR4200 to DSP56F83x (Hawk) Using the AMI (Example) . . . . . . . . . . 191
Figure 3-145. FlexRay CC to HCS12 Device Connection with HCS12 EBI Paged Mode Support. . . 193
Figure 3-146. FlexRay CC to HCS12 Device Connection with HCS12 EBI Unpaged Mode Support 194
Figure 3-147. HCS12 interface Address Decoding and Internal CS Signal Generation . . . . . . . . . . . . 195
Figure 3-148. Timing Diagram of CC State Transition from Configuration State to Normal State . . . 200
Figure 3-149. Start of Communication Cycle and Start of Offset Correction Functions Timing . . . . . 204
Figure 3-150. Timing for Debug Functions with Three EXTAL or CC_CLK Clock Cycles
of High State (Logic “1“) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Figure 3-151. Slot Start in Static Segment Function Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Figure 4-1.
VREG3V3 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Figure 5-1.
Power-on Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Figure 5-2.
Low Voltage Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Figure 5-3.
External Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
17
Figure Number
Figure A-1.
Figure A-2.
Figure A-3.
Figure A-4.
Figure A-5.
Figure B-1.
Figure B-2.
Figure B-3.
Figure C-1.
Figure C-1.
Figure C-2.
Figure C-3.
Figure C-4.
Title
Page
Voltage Regulator — Chip Power-up and Voltage Drops (not scaled) . . . . . . . . . . . . . 230
AMI Interface Read and Write Timing Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
AMI Interface Write-after-Read Transactions Timing Diagram . . . . . . . . . . . . . . . . . . 234
AMI Interface Read-after-Write Transactions Timing Diagram . . . . . . . . . . . . . . . . . . 234
HCS12 Interface Read/write Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
64-pin LQFP Mechanical Dimensions (Case N 840F-02) (Page 1) . . . . . . . . . . . . . . . . 239
64-pin LQFP Mechanical Dimensions (Case N 840F-02) (Page 2) . . . . . . . . . . . . . . . . 240
64-pin LQFP Mechanical Dimensions (Case N 840F-02) (Page 3) . . . . . . . . . . . . . . . . 241
Recommended PCB Layout (64-pin LQFP) for Standard Pierce Oscillator Mode . . . . 244
Protocol Operation Control (POC) - 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Protocol Operation Control (POC) - 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
POC — Normal Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
POC — Passive Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
MFR4200 Data Sheet, Rev. 0
18
Freescale Semiconductor
List of Tables
Table Number
Title
Page
Table 1-1.
Table 1-2.
Table 2-1.
Table 2-2.
Table 2-3.
Table 2-4.
Table 2-5.
Table 2-6.
Table 2-7.
Table 2-8.
Table 2-9.
Table 3-1.
Table 3-2.
Table 3-3.
Table 3-4.
Table 3-5.
Table 3-6.
Table 3-7.
Table 3-8.
Table 3-9.
Table 3-10.
Table 3-11.
Table 3-12.
Table 3-13.
Table 3-14.
Table 3-15.
Table 3-16.
Table 3-17.
Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Notational Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Interface Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Clockout Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Bus Driver Type Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Voltage Regulator VDDR Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Device Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Assigned Part ID Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Pin Functions and Signal Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
MFR4200 Power and Ground Connection Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Recommended Pullup/down Resistor Values for IF_SEL[0:1] and CLK_S[0:1] Inputs . . 46
Register Map Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Bus Driver Type Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Encoding of Debug Port Control Fields CNTRL[7:4] and CNTRL[3:0] . . . . . . . . . . . . . . 88
CC State Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Mapping between Receive Message Buffer Payload Bytes and GNMVnR Registers . . . . 96
Channel Configuration for SSCCnR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Error Handling Level Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Mapping between SSSnR and SSnR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
FIFO Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
FIFO Channel Filtering Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Receive Message Buffer Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Receive FIFO Message Buffer Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Transmit Message Buffer Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Mapping between Buffer Layout and Active Receive/Transmit/FIFO Message Buffers. 143
Channel Filtering Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
CC Buffer Fields Accessibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Double Transmit Message Buffer Data Collection with State Driven Transmit
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Table 3-18. Double Transmit Message Buffer Data Collection with Event Driven Transmit
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Table 3-19. FlexRay CC MCU Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Table 3-20. AMI Interface Signals and Pins Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
19
Table Number
Table 3-21.
Table 3-22.
Table 3-23.
Table 4-1.
Table 4-2.
Table 5-1.
Table A-1.
Table A-2.
Table A-3.
Table A-4.
Table A-5.
Table A-6.
Table A-7.
Table A-8.
Table A-9.
Table A-10.
Table A-11.
Table A-12.
Table A-13.
Table A-14.
Table C-1.
Title
Page
HCS12 Interface Signal and Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
CLKOUT Frequency Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Debug Port Functions Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
VREG3V3V2 — Signal Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
VREG3V3V2 — Reset Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
MFR4200 Pins Relevant to the CRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
ESD and Latch-up Test Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
ESD and Latch-up Protection Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Thermal Package Simulation Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
5V I/O Characteristics (VDD5 = 5V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
3.3V I/O Characteristics (VDD5 = 3.3V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
Supply Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Voltage Regulator - Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Voltage Regulator Recommended Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Startup Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Oscillator Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
AMI Interface AC Switching Characteristics over the Operating Range . . . . . . . . . . . . 235
HCS12 Interface Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Suggested External Component Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
MFR4200 Data Sheet, Rev. 0
20
Freescale Semiconductor
Chapter 1
Introduction
This data sheet provides information on a system that includes the MFR4200 FlexRay Communication
Controller Module.
1.1
Audience
This data sheet is intended for application and system hardware developers who wish to develop products
for the FlexRay MFR4200. It is assumed that the reader understands FlexRay protocol functionality and
microcontroller system design.
1.2
Additional Reading
For additional reading that provides background to, or supplements, the information in this manual:
• Appendix C, “MFR4200 Protocol Implementation Document”
• For more information about the FlexRay protocol, refer to the following document:
— FlexRay Communications System Protocol Specification V1.1, FlexRay Consortium, 2004.
• For more information about Philips Bus Guardian and Bus Driver devices, refer to the following
documents:
— FlexRay Electrical Physical Layer Specification, v1.5, FlexRay Consortium, 2004,
— FlexRay Bus Guardian Preliminary Functional Specification, v1.9, FlexRay Consortium, June
2004.
• For more information about RS485 transceivers:
— About the MAX3078 transceiver (IDLE state coded as “1”)
http://pdfserv.maxim-ic.com/en/ds/MAX3070E-MAX3079E.pdf
— About the MAX3485 transceiver (IDLE state coded as “0”)
http://pdfserv.maxim-ic.com/en/ds/MAX3483-MAX3491.pdf
• For more information about the Power PC interface, refer to the Freescale products section at
www.freescale.com.
• For more information about M9HCS12 Family devices and M9HCS12 programming, refer to the
Freescale Products section at www.freescale.com.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
21
Introduction
1.3
Terminology
Table 1-1. Acronyms and Abbreviations
Term
Meaning
AMI
Asynchronous memory interface
BG
Bus guardian
CC
Communication controller (an alternative term for the MFR4200)
ceil
Function ceil(x) returns the nearest integer greater than or equal to x
Cycle length in µT
The actual length of a cycle in µT for the ideal controller (± 0 ppm)
EBI
External bus interface
FSS
Frame start sequence
Host
The FlexRay CC host MCU
LSB
Less/least significant bit
MCU
Microcontroller
MSB
More/most significant bit
MT
Macrotick
µT
Microtick
NIT
Network idle time
PHY
Physical interface
PS
FlexRay Communications System Protocol Specification
PWD
Protocol working document
RX
Reception
TCU
Time control unit
TX
Transmission
TDMA
Time division multiplex access
Table 1-2. Notational Conventions
active-high
Names of signals that are active-high are shown in upper case text, without a ‘#’ symbol at the end.
Active-high signals are asserted (active) when they are high and negated when they are low.
active-low
A ‘#’ symbol at the end of a signal name indicates that the signal is active-low.
An active-low signal is asserted (active) when it is at the logic low level and is negated when it is at the
logic high level.
asserted
A signal that is asserted is in its active logic state. An active-low signal changes from high to low when
asserted; an active-high signal changes from low to high when asserted.
negated
A signal that is negated is in its inactive logic state. An active-low signal changes from low tohigh when
negated; an active-high signal changes fromhigh to low when negated.
set
To set a bit means to establish logic level one on the bit.
clear
To clear a bit means to establish logic level zero on the bit.
MFR4200 Data Sheet, Rev. 0
22
Freescale Semiconductor
Part Number Coding
Table 1-2. Notational Conventions (continued)
0x0F
The prefix “0x” denotes a hexadecimal number.
0b0011
The prefix “0x” denotes a binary number.
x
In certain contexts, such as a signal encoding, this indicates “don’t care”. For example, if a field is binary
encoded 0bx001, the state of the first bit is “don’t care”.
==
Used in equations, this symbol signifies comparison.
1.4
Part Number Coding
P FR 4200 M PB 40
Speed Option
40 = 40 MHz
Package Option
PB = 64-pin LQFP
AE = 64-pin Lead Free / Halide Free LQFP
Temperature Option
M = -40oC to +125oC
Device Title
Controller Family
Qualification
P = Engineering Sample
M = Qualified part
Figure 1-1. Order Part Number Coding
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
23
Introduction
MFR4200 Data Sheet, Rev. 0
24
Freescale Semiconductor
Introduction
Chapter 2
Device Overview
2.1
Introduction
The FlexRay Communication Controller MFR4200 implements the FlexRay protocol in accordance with
Appendix C, “MFR4200 Protocol Implementation Document”. This appendix refers to FlexRay
Communications System Protocol Specification V1.1 for most protocol mechanisms, and complements
the protocol specification where necessary.
The controller host interface (CHI) of the FlexRay Communication Controller MFR4200 is implemented
in accordance with Chapter 3, “MFR4200 FlexRay Communication Controller”.
2.1.1
Features
The following list of features is not comprehensive, but is a selection of the most important features.
Detailed descriptions of the protocol and the CHI features are provided in the following.
• Chapter 3, “MFR4200 FlexRay Communication Controller”
• Appendix C, “MFR4200 Protocol Implementation Document”
The most important features are:
• Bit rate up to a maximum of 10 Mbit/sec on each of two channels.
• 59 message buffers, each with a payload of up to 32 bytes of data.
• FlexRay frames with up to 254 payload data bytes. Padding is used for FlexRay payload data that
exceeds the 32-byte data size boundary.
• One configurable receive FIFO.
• Each message buffer configurable as a receive message buffer, or as a transmit message buffer
(single or double), or as part of the receive FIFO.
• Two receive shadow message buffers available to each channel.
• Message buffer configurable with state or event semantics.
• Flexible error signaling mechanism providing eight configurable counters, slot status indicators
and interrupts.
• Internal measured time difference values used for clock synchronization can be read via the CHI.
• The status of up to four slots can be observed independently of the communication controller
receive buffers.
• The host accesses all message buffers by means of three active message buffers (active transmit
message buffer, active message receive buffer, and active receive FIFO buffer) in the CHI.
• Configurable message filtering based on frame ID, cycle counter, and channel, for transmit and
receive message buffers.
• Configurable message filtering based on frame ID, channel, and message ID, for the receive FIFO.
• Duration of the communication cycle configurable in microticks.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
25
Device Overview
2.1.2
•
•
•
•
•
•
•
Implementation Details and Constraints
The MFR4200 provides two hardware selectable host interfaces:
— HCS12 interface, for direct connection to Freescale’s HCS12 family of microcontrollers.
The HCS12 interface clock signal used to synchronize data transfer can run at a maximum rate
of 8 MHz.
— Asynchronous memory interface (AMI), for asynchronous connection to microcontrollers.
Internal 40 MHz quartz oscillator.
Internal voltage regulator for the digital logic and the oscillator.
Hardware selectable clock output to drive external host devices: Disabled/4/10/40 MHz.
Maskable interrupt sources available over one interrupt output line.
Glueless electrical physical layer interface compatible with dedicated FlexRay physical layer.
Industry standard RS485 physical layer device can be used with additional glue logic.
Two pins have multiplexed strobe functions.
NOTE
Refer to Chapter 3, “MFR4200 FlexRay Communication Controller” for
more implementation details and constraints.
2.1.3
Modes of Operation
NOTE
This section depicts only the MFR4200 device modes, not the FlexRay
protocol operating modes of the MFR4200 FlexRay module. Refer to
Chapter 3, “MFR4200 FlexRay Communication Controller for more
information on the FlexRay module operating modes.
Only one user mode is available on the MFR4200 — normal operating mode.
In normal operating mode, the selections described below are possible.
2.1.3.1
Interface Selection
The external interface is selected by means of the IF_SEL[0:1] pins, as shown in Table 2-1.
Table 2-1. Interface Selection
Pin
Interface
IF_SEL0
IF_SEL1
0
0
Reserved
0
1
HCS12 synchronous interface
1
0
Asynchronous Memory Interface
1
1
Reserved
MFR4200 Data Sheet, Rev. 0
26
Freescale Semiconductor
Introduction
NOTE
As the IF_SEL[0:1] signals share pins with physical layer interface signals,
the interface type must be selected using either pullup or pulldown resistors.
IF_SEL[0:1] signals are inputs during the internal reset sequence and are
latched by the internal reset signal level. Refer to Chapter 5, “Clocks and
Reset Generator” for more information.
2.1.3.2
Clockout Selection
The CLK_S[0:1] pins select the CLKOUT pin output clock frequency or disable the output clock.
Table 2-2. Clockout Selection
Pin
CLKOUT Function
CLK_S0
CLK_S1
0
0
4 MHz output
1
0
10 MHz output
0
1
40 MHz output
1
1
Disabled (CLKOUT output is “0”)
NOTE
As CLK_S[0:1] signals share pins with physical layer interface signals, the
CLKOUT function must be selected using either pullup or pulldown
resistors.
CLK_S[0:1] signals are inputs during the internal reset sequence and are
latched by the internal reset signal level. Refer to Chapter 5, “Clocks and
Reset Generator for more information.
2.1.3.3
Bus Driver Type Selection
The SCM[0:1] bits of the MCR0 register (see Chapter 3, “MFR4200 FlexRay Communication Controller)
select the bus driver type.
Table 2-3. Bus Driver Type Selection
1
Driver Type
SCM1
SCM0
RS485 (IDLE state coded as ’0’)1
0
0
Optical/Electrical PHY
0
1
Reserved
1
0
RS485 (IDLE state coded as ’1’)1
1
1
Refer to Section 1.2, “Additional Reading” for more information on RS485.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
27
Device Overview
NOTE
It is not possible to mix in a cluster or per channel:
•
•
2.1.3.4
Different RS485;
RS485 and Optical/Electrical PHY.
Internal VREG Enable/Disable Selection
Table 2-4. Voltage Regulator VDDR Connection
1
2.1.4
VDDR
Description
Supplied with VDD51
Internal Voltage Regulator enabled
Tied to ground
Internal Voltage Regulator disabled
Refer to Section A.1.7, “Operating Conditions” for the VDD5
Block Diagram
Figure 2-1 shows a block diagram of the MFR4200 device.
MFR4200 Data Sheet, Rev. 0
28
Freescale Semiconductor
Introduction
VDDR
VSSR
VDDA
Voltage Regulator
VDD2_5
VSSA
VSS2_5
RESET#
XTAL
EXTAL/CC_CLK
VDDOSC
VSSOSC
Clock and Reset
Generation Module
Oscillator
A1/XADDR19
D1/PAD14
A2/XADDR18
A3/XADDR17
D2/PAD13
D0/PAD15
D3/PAD12
A4/XADDR16
A5/XADDR15
A6/XADDR14
HCS12
Interface
Asynchronous
Memory Interface
D4/PAD11
D5/PAD10
A7/ACS0
D6/PAD9
A8/ACS1
A9/ACS2
OE#/ACS3
ACS4
D7/PAD8
D8/PAD7
D9/PAD6
D10/PAD5
ACS5
WE#/RW_CC#
D11/PAD4
D12/PAD3
CE#/LSTRB
D13/PAD2
Host Interface
ECLK_CC
D14/PAD1
INT_CC#
D15/PAD0
RXD_BG1/RXD1_485
Receiver Channel A
BGE1
RXD_BG2/RXD2_485
Receiver Channel B
BGE2
TXD_BG1/TXD1_485/IF_SEL1
Transmitter Channel A
TXEN1#/ TXE1_485#
TXD_BG2/TXD2_485
Transmitter Channel B
TXEN2#/ TXE2_485#
MT/CLK_S1
TCU
ARM/DBG1/CLK_S0
BGT/DBG2/IF_SEL0
Debug Strobe
External Clock Generator
CLKOUT
CLKOUT/TM0
TEST
Supply Pins
VREG input analog
VDDA
VSSA
VREG input
VDDR
VSSR
Internal Logic
Oscillator
VDD2_5
VDDOSC
VSS2_5
VSSOSC
I/O Driver
VDDX[1..4]
VSSX[1..4]
Figure 2-1. MFR4200 Block Diagram
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
29
Device Overview
2.1.5
Memory Map
Table 2-5 shows the device memory map of the MFR4200 after a hard reset.
Table 2-5. Device Memory Map
Address (Hex)
Module
Size (bytes)
0x000–0x018
General Control Registers
26
0x01A–0x01E
Acceptance Filter Registers
6
0x024–0x04A
General Control Registers
40
0x04C–0x082
Slot Status Registers
56
0x084–0x0FE
General Control Registers
124
0x100–0x126
Active Receive FIFO Buffer
40
0x128–0x13E
Reserved, read-only location
24
0x140–0x166
Active Receive Message Buffer
40
0x168–0x17E
Reserved, read-only location
24
0x180–0x1A6
Active Transmit Message Buffer
40
0x1A8–0x1FE
Reserved, read-only location
88
0x200–0x2FE
Buffer Control, Configuration and Status Registers,
Cycle Counter Filters Registers
256
0x300–0x31E
Reserved, read-only location
32
0x320–0x3FE
General Status Registers
224
The FlexRay block defines the MFR4200 address memory map. Refer to Chapter 3, “MFR4200 FlexRay
Communication Controller for the detailed register map.
MFR4200 Data Sheet, Rev. 0
30
Freescale Semiconductor
Signal Descriptions
2.1.6
Part ID Assignments
The part ID is located in two 16-bit registers, MVR0 and MVR1, at addresses 0x002 and 0x098 (see
Chapter 3, “MFR4200 FlexRay Communication Controller). This read-only value is a unique part ID for
each revision of the chip. Table 2-6 shows the assigned part ID number.
Table 2-6. Assigned Part ID Numbers
Part ID1
Device
1
Mask Set Number
MVR0
MVR1
MFR4200
0L60X
0x9042
0x0000
MFR4200
1L60X
0x9042
0x0001
The coding is as follows (see also the MVR0 and MVR1 register descriptions in Chapter 3, “MFR4200
FlexRay Communication Controller):
MVR0:
Bit 15-12: Major release of the FlexRay block in the MFR4200 device
Bit 11-08: Minor release of the FlexRay block in the MFR4200 device
Bit 07-00: Device Part ID1
MVR1:
Bit 15-08: Device Part ID2.
Bit 07-04: Major release of the MFR4200 device.
Bit 03-00: Minor release of the MFR4200 device.
2.2
Signal Descriptions
This section describes the signals that connect off-chip. It includes a pinout diagram, a table of signal
properties, and a detailed discussion of each signal.
2.2.1
System Pinout
The MFR4200 is available in a 64-pin low profile quad flat package (LQFP). Most pins perform two or
more functions, as described in Section 2.2.2, “Pin Functions and Signal Properties”. Figure 2-2 shows the
pin assignments.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
31
Device Overview
D5/PAD10
D4/PAD11
D3/PAD12
VDDX3
VSSX3
ECLK_CC
D2/PAD13
VDDA
VSSA
58
57
56
55
54
53
52
51
50
49
61
D6/PAD9
62
59
D7/PAD8
63
60
D8/PAD7
64
VSS2_5
CLKOUT
VDD2_5
INT_CC#
TEST
1
48
MT/CLK_S12
D9/PAD6
2
47
ARM/DBG11/CLK_S02
D10/PAD5
3
46
BGE2
D11/PAD4
4
45
TXD_BG2/TXD2_485
D12/PAD3
5
44
TXEN2#TXE2_485#
D13/PAD2
6
43
RXD_BG2/RXD2_485
D14/PAD1
7
42
BGE1
VDDX1
8
41
TXD_BG1/TXD1_485/IF_SEL12
VSSX4
WE#/RW_CC
BGT/DBG21/IF_SEL02
CE#/LSTRB
32
30
ACS4
31
29
OE#/ACS3
RXD_BG1/RXD1_485
28
33
VDDOSC
16
27
RESET#
XTAL
ACS5
26
34
25
15
EXTAL/CC_CLK
VDDX4
A5/XADDR15
24
35
VSSOSC
14
A9/ACS2
TXEN1#/TXE1_485#
A4/XADDR16
23
VDDX2
36
A8/ACS1
37
13
22
12
A3/XADDR17
21
A2/XADDR18
VDDR
VSSX2
20
38
VSSR
11
A7/ACS0
D0/PAD15
A1/XADDR19
19
D1/PAD14
39
A6/XADDR14
40
18
9
10
17
VSSX1
D15/PAD0
Notes:
1 One of the following internal signals can be output through the DBG1 or DBG2 pin:
PCS, SSS, RAGFB, MSS, DSSB, SFB, RCFB, SCC, RAGFA, MTS, SOC, DSSA, SFA, RCFA. (See
Table 3-3 and Table 3-23.)
2 CLK_S[1:0] and IF_SEL[1:0] are inputs during the internal reset sequence, and are latched by the
internal reset signal level.
Figure 2-2. Pin Assignments for MFR4200 in 64-pin LQFP
2.2.2
Pin Functions and Signal Properties
Table 2-7 provides a summary of all pin functions and signal properties shown in Figure 2-2.
MFR4200 Data Sheet, Rev. 0
32
Freescale Semiconductor
Signal Descriptions
Table 2-7. Pin Functions and Signal Properties
Pin
Pin1
N Function1
Pin1
Pin1
Function2 Function3
Powered
by
In/
Out
Pin
type2,3
Re
set
Functional Description
Host Interface Pins
11
A1
XADDR19
-
VDDX
I
PC
-
AMI address bus / HCS12 expanded address
lines. A1= LSB of the AMI address bus.
12
A2
XADDR18
-
VDDX
I
PC
-
AMI address bus / HCS12 expanded address
lines.
13
A3
XADDR17
-
VDDX
I
PC
-
AMI address bus / HCS12 expanded address
lines.
14
A4
XADDR16
-
VDDX
I
PC
-
AMI address bus / HCS12 expanded address
lines.
15
A5
XADDR15
-
VDDX
I
PC
-
AMI address bus / HCS12 expanded address
lines.
17
A6
XADDR14
-
VDDX
I
PC
-
AMI address bus / HCS12 expanded address
lines. XADDR14 = LSB of the HCS12 expanded
address lines
18
A7
ACS0
-
VDDX
I
PC
-
AMI address bus / HCS12 address select
inputs.
21
A8
ACS1
-
VDDX
I
PC
-
AMI address bus / HCS12 address select
inputs.
22
A9
ACS2
-
VDDX
I
PC
-
AMI address bus / HCS12 address select
inputs.
27
OE#4
ACS3
-
VDDX
I
PC
-
AMI read output enable signal / HCS12 address
select input.
28
ACS4
-
-
VDDX
I
PC
-
HCS12 address select inputs.
34
ACS5
-
-
VDDX
I
PC
-
HCS12 address select inputs. MSB of the
address select inputs.
10
D15
PAD0
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus. PAD0 is the LSB of the HCS12
address/data bus.
7
D14
PAD1
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
6
D13
PAD2
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
5
D12
PAD3
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
4
D11
PAD4
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
3
D10
PAD5
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
2
D9
PAD6
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
33
Device Overview
Table 2-7. Pin Functions and Signal Properties (continued)
Pin
Pin1
N Function1
Pin1
Pin1
Function2 Function3
Powered
by
In/
Out
Pin
type2,3
Re
set
Functional Description
62
D8
PAD7
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
61
D7
PAD8
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
58
D6
PAD9
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
57
D5
PAD10
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
56
D4
PAD11
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
55
D3
PAD12
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
51
D2
PAD13
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
40
D1
PAD14
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus.
39
D0
PAD15
-
VDDX
I/O
Z/DC/PC
Z
AMI data bus / HCS12 multiplexed address/data
bus. D0 is the LSB of the AMI data bus
29
CE#
LSTRB
-
VDDX
I
PC
-
AMI chip select signal / HCS12 low-byte strobe
signal
30
WE#
RW_CC#
-
VDDX
I
PC
-
AMI write enable signal/ HCS12 read/write
select signal
52
ECLK_CC
-
-
VDDX
I
PC
-
HCS12 clock input
Physical Layer Interface
32
BGT
DBG2
IF_SEL0
VDDX
I/O
DC/PD
-
Bus Guardian Tick / Debug strobe point signal
2/Host interface selection 0
48
MT
CLK_S1
-
VDDX
I/O
DC/PD
-
Bus Guardian Macrotick/Controller clock output
select signal 1
47
ARM
DBG1
CLK_S0
VDDX
I/O
DC/PD
-
Bus Guardian ARM signal / Debug strobe point
signal1/Controller clock output select signal 0
33
RXD_BG1
RXD2_485
-
VDDX
I
PC
-
PHY Data receiver input / RS485 Data receiver
input
43
RXD_BG2
RXD2_485
-
VDDX
I
PC
-
PHY Data receiver input / RS485 Data receiver
input
36
TXEN1#
TXE1_485#
-
VDDX
O
DC
1
Transmit enable for PHY / Transmit enable for
RS485
44
TXEN2#
TXE2_485#
-
VDDX
O
DC
1
Transmit enable for PHY / Transmit enable for
RS485
MFR4200 Data Sheet, Rev. 0
34
Freescale Semiconductor
Signal Descriptions
Table 2-7. Pin Functions and Signal Properties (continued)
Pin
Pin1
N Function1
Pin1
Pin1
Function2 Function3
41
TXD_BG1
TXD1_485
45
TXD_BG2
42
46
Powered
by
In/
Out
Pin
type2,3
Re
set
IF_SEL1
VDDX
I/O
DC/PD
-
PHY Data transmitter output / RS485 Data
transmitter output / Host interface selection 1
TXD2_485
-
VDDX
O
DC
0
PHY Data transmitter output / RS485 Data
transmitter output
BGEN1
-
-
VDDX
I
PC
-
Bus Guardian Enable monitor input
BGEN2
-
-
VDDX
I
PC
-
Bus Guardian Enable monitor input
-
Controller clock output selectable as disabled or
4/10/40 MHz
Functional Description
Clock Signals
63
CLKOUT
-
-
VDDX
I/O
DC
Others
16
RESET#
-
-
VDDX
I
-
-
Hardware reset input
64
INT_CC#
-
-
VDDX
O
OD/DC
1
Controller interrupt output
1
TEST
-
-
VDDX
I
-
-
Must be tied to logic low in application.
Oscillator
24
EXTAL
CC_CLK
-
25
XTAL
-
-
VDDOSC
I
-
-
Crystal driver / External clock pin
I
-
-
Crystal driver pin
Supply/Bypass Filter pins
8
VDDX1
-
-
-
-
-
-
Supply voltage, I/O
37
VDDX2
-
-
-
-
-
-
Supply voltage, I/O
54
VDDX3
-
-
-
-
-
-
Supply voltage, I/O
35
VDDX4
-
-
-
-
-
-
Supply voltage, I/O
9
VSSX1
-
-
-
-
-
-
Supply voltage ground, I/O
38
VSSX2
-
-
-
-
-
-
Supply voltage ground, I/O
53
VSSX3
-
-
-
-
-
-
Supply voltage ground, I/O
31
VSSX4
-
-
-
-
-
-
Supply voltage ground, I/O
20
VDDR
-
-
-
-
-
-
Supply voltage, supply to pin drivers and
internal voltage regulator
19
VSSR
-
-
-
-
-
-
Supply voltage ground, ground to pin drivers
and internal voltage regulator
50
VDDA
-
-
-
-
-
-
Supply analog voltage
49
VSSA
-
-
-
-
-
-
Supply analog voltage ground
59
VDD2_5,4
-
-
-
-
-
-
Core voltage power supply output (nominally
2.5V)
60
VSS2_54
-
-
-
-
-
-
Core voltage ground output
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
35
Device Overview
Table 2-7. Pin Functions and Signal Properties (continued)
Pin
Pin1
N Function1
Pin1
Pin1
Function2 Function3
Powered
by
In/
Out
Pin
type2,3
Re
set
Functional Description
26
VDDOSC4
-
-
-
-
-
-
Oscillator voltage power supply output
(nominally 2.5 V)
23
VSSOSC4
-
-
-
-
-
-
Oscillator voltage ground output
1
# – signal is active-low.
PC (Pullup/down Controlled) – Register controlled internal weak pullup/down for a pin in input mode. Refer to the following
sections for more information:
– Section 3.2.3.2.5, “Host Interface Pins Pullup/down Enable Register (HIPPER)”
– Section 3.2.3.2.6, “Host Interface Pins Pullup/down Control Register (HIPPCR)”
– Section 3.2.3.2.7, “Physical Layer Pins Pullup/down Enable Register (PLPPER)”
– Section 3.2.3.2.8, “Physical Layer Pins Pullup/down Control Register (PLPPCR)”
PD (Pull Down) – Internal weak pulldown for a pin in input mode.
DC (Drive strength Controlled) – Register controlled drive strength for a pin in the output mode. Refer to the following for more
information:
– Section 3.2.3.2.3, “Host Interface and Physical Layer Pins Drive Strength Register (HIPDSR)”
– Section 3.2.3.2.4, “Physical Layer Pins Drive Strength Register (PLPDSR)”
Z – Three-stated pin.
OD (Open Drain) – Output pin with open drain.
3 Reset state:
– All pins with the PC option have pullup/down resistors disabled.
– All pins with the DC option have full drive strength.
4 No load allowed except for bypass capacitors.
2
2.2.3
2.2.3.1
Detailed Signal Descriptions
A[1:6]/XADDR[19:14] — AMI Address Bus, HCS12 Expanded Address
Inputs
A[1:6]/XADDR[19:14] are general purpose input pins. Their function is selected by the IF_SEL[0:1] pins.
Refer to Section 3.7, “Host Controller Interfaces” for more information. The pins can be configured to
enable or disable either pullup or pulldown resistors on the pins. (See Section 3.2.3.2.5, “Host Interface
Pins Pullup/down Enable Register (HIPPER)” and Section 3.2.3.2.6, “Host Interface Pins Pullup/down
Control Register (HIPPCR)”.)
A[1:6] are AMI interface address signals. A1 is the LSB of the AMI address bus.
XADDR[19:14] are HCS12 interface expanded address lines. XADDR14 is the LSB of the HCS12
interface expanded address lines.
2.2.3.2
A[7:9]/ACS[0:2] — AMI Address Bus, HCS12 Expanded Address Inputs
A[7:9]/ACS[0:2] are general purpose input pins. Their function is selected by the IF_SEL[0:1] pins. Refer
to Section 3.7, “Host Controller Interfaces” for more information. The pins can be configured to enable or
disable either pullup or pulldown resistors on the pins.
MFR4200 Data Sheet, Rev. 0
36
Freescale Semiconductor
Signal Descriptions
A[7:9] are AMI interface address signals.
ACS[0:2] are HCS12 interface address select signals.
2.2.3.3
OE#/ACS3 — AMI Read Output Enable, HCS12 Address Select Input.
OE#/ACS3 is a general purpose input pin. Its function is selected by the IF_SEL[0:1] pins. Refer to
Section 3.7, “Host Controller Interfaces” for more information. The pin can be configured to enable or
disable either a pullup or pulldown resistor on the pin.
OE# is the AMI interface output enable signal. This signal controls MFR4200 data output and the state of
three-stated data pins D[15:0] during host read operations.
ACS3 is an HCS12 interface address select signal.
2.2.3.4
ACS[4:5] — HCS12 Address Select Inputs
ACS[4:5] are general purpose input pins.Their function is selected by the IF_SEL[0:1] pins. Refer to
Section 3.7, “Host Controller Interfaces” for more information. The pins can be configured to enable or
disable either pullup or pulldown resistors on the pins.
ACS[4:5] are HCS12 interface address select signals. ACS5 is the MSB of the address select inputs.
2.2.3.5
D[15:0]/PAD[0:15] — AMI Data Bus, HCS12 Multiplexed Address/Data
Bus
D[15:0]/PAD[0:15] are general purpose input or output pins. Their functions are selected by the
IF_SEL[0:1] pins. Refer to Section 3.7, “Host Controller Interfaces” for more information. These pins can
be configured to provide either high or reduced output drive, and also to enable or disable either pullup or
pulldown resistors on the pins.
D[15:0] are data signals of the AMI interface. D0 is the LSB of the AMI data bus.
PAD[0:15] are HCS12 interface multiplexed address/data signals in the HCS12 Host interface mode of
operation. PAD0 is the LSB of the HCS12 address/data bus.
2.2.3.6
CE#/LSTRB — AMI Chip Select, HCS12 Low-byte Strobe
The function of this pin is selected by IF_SEL[0:1] pins. Section 3.7, “Host Controller Interfaces” for more
information. The pin can be configured to enable or disable either a pullup or pulldown resistor on the pin.
CE# is an AMI interface transfer size input signal. It indicates the size of the requested data transfer in the
current bus cycle.
LSTRB is an HCS12 interface low-byte strobe input signal. It indicates the type of bus access.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
37
Device Overview
2.2.3.7
WE#/RW_CC# — AMI Write Enable, HCS12 Read/Write Select
The function of this pin is selected by IF_SEL[0:1] pins. Refer to Section 3.7, “Host Controller Interfaces”
for more information. The pin can be configured to enable or disable either a pullup or pulldown resistor
on the pin.
WE# is an AMI interface write select signal. It strobes the valid data provided by the host on the D[15:0]
pins during write operations to the MFR4200 memory.
RW_CC# is an HCS12 interface read/write input signal. It indicates the direction of data transfer for a
transaction.
2.2.3.8
ECLK_CC — HCS12 Clock Input
ECLK_CC is the HCS12 interface clock input signal. The input clock frequency can be up to 8 MHz in
the HCS12 mode of the external interface block. The pin can be configured to enable or disable either a
pullup or pulldown resistor on the pin.
2.2.3.9
BGT/DBG2/IF_SEL0 — Bus Guardian Tick, Debug Strobe Point 2, Host
Interface Selection 0
BGT is a bus guardian tick clock output signal provided from the CC. If a Bus Guardian device is not used
in an application, this pin may be left open.
BGT is active, irrespective of which physical layer is selected. If the RS485 Driver type is selected, this
pin is not used.
This signal should be connected to the bus guardian on each channel. The pin can be configured to provide
either high or reduced output drive.
DBG2 is debug strobe point output 2. The function output on this pin is selected by the debug port control
register. Refer to Section 3.10, “Debug Port” for more information.
IF_SEL0 is the CC external interface selection input signal. Refer to Table 2-1 for the selection coding.
NOTE
The IF_SEL[0:1] signals are inputs during the internal reset sequence and
are latched by the internal reset signal level.
While the IF_SEL0 value is being latched, the output drive control is
disabled and the internal pulldown resistor is connected to the pin.
As the IF_SEL[0:1] signals share pins with Physical Layer Interface signals,
pullup/down devices must be used for selection. Recommended
pullup/down resistor values for the IF_SEL[0:1] inputs are given in
Section 2.4.2, “Recommended Pullup/down Resistor Values”.
2.2.3.10
MT/CLK_S1 — Bus Guardian Macrotick, Clock Output Select 1
MT is a Bus Guardian macrotick output signal from the CC. If a bus guardian device is not used in an
application, this pin may be left open.
MFR4200 Data Sheet, Rev. 0
38
Freescale Semiconductor
Signal Descriptions
MT is active, irrespective of which physical layer is selected. If the RS485 driver type is selected, this pin
is not used.
This signal should be connected to the Bus Guardians on each channel. The pin can be configured to
provide either high or reduced output drive.
CLK_S1 is the CLKOUT clock frequency selection input signal. See Table 2-2.
NOTE
CLK_S[0:1] signals are inputs during the internal reset sequence and are
latched by the internal reset signal level.
While the CLK_S1 value is being latched, the output drive control is
disabled and the internal pulldown resistor is connected to the pin.
As CLK_S[0:1] signals share pins with Physical Layer Interface signals,
pullup/down devices must be used for the selection. Recommended
pullup/down resistor values for the CLK_S[0:1] inputs are given in
Section 2.4.2, “Recommended Pullup/down Resistor Values”.
2.2.3.11
ARM/DBG1/CLK_S0 — Bus Guardian ARM, Debug Strobe Point 1, Clock
Output Select 0
ARM is an output signal from the CC to a bus guardian. If a bus guardian device is not used in an
application, this pin may be left open.
ARM is active, irrespective of which physical layer is selected. If the RS485 driver type is selected, this
pin is not used.
This signal should be connected to the bus guardian on each channel. The pin can be configured to provide
either high or reduced output drive.
DBG1 is the debug strobe point output 1. The function output on this pin is selected by the debug port
control register. Refer to Section 3.10, “Debug Port” for more information.
CLK_S0 is the CLKOUT clock frequency selection input signal. See Table 2-2.
NOTE
CLK_S[0:1] signals are inputs during the internal reset sequence and are
latched by the internal reset signal level.
While the CLK_S0 value is being latched, the output drive control is
disabled and the internal pulldown resistor is connected to the pin.
As CLK_S[0:1] signals share pins with Physical Layer Interface signals,
pullup/down devices must be used for selection. Recommended
pullup/down resistor values for the CLK_S[0:1] inputs are given in the
Section 2.4.2, “Recommended Pullup/down Resistor Values”.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
39
Device Overview
2.2.3.12
RXD_BG[1:2]/RXD[1:2]_485 — PHY Received Data, RS485 Received Data
The function of this pin is selected by the SCM[0:1] bits in the MCR0 register. Refer to Section 3.2.3.2.1,
“Module Configuration Register 0 (MCR0)” for more information. The pins can be configured to enable
or disable either pullup or pulldown resistors on the pins.
RXD_BG[1:2] are bus driver receive data input signals if the FlexRay Optical/Electrical PHY is
configured:
• RXD_BG1 is the input to the CC from Physical Layer Channel 1.
• RXD_BG2 is the input to the CC from Physical Layer Channel 2.
RXD[1:2]_485 are bus driver receive data input signals if the RS485 Driver type is configured:
• RXD1_485 is the input to the CC from Physical Layer Channel 1
• RXD2_485 is the input to the CC from Physical Layer Channel 2.
2.2.3.13
TXEN[1:2]#/TXE[1:2]_485# — PHY Transmit Enable, RS485 Transmit
Enable
TXEN[1:2]# are bus driver transmit enable output signals if the FlexRay Optical/Electrical PHY is
configured:
• TXEN1# is the output of the CC to Physical Layer Channel 1
• TXEN2# is the output of the CC to Physical Layer Channel 2.
TXE[1:2]_485# are Bus Driver Transmit Enable output signals if the RS485 Driver type is configured:
• TXE1_485# is the output of the CC to the Physical Layer Channel 1.
• TXE2_485# is the output of the CC to the Physical Layer Channel 2.
Refer to Figure 2-10 for an example RS485 bus driver connection using external glue logic.
The pins can be configured to provide either high or reduced output drive.
2.2.3.14
TXD_BG1/TXD1_485/ IF_SEL1 — PHY Transmit Data 1, RS485 Transmit
Data 1, Host Interface Selection 1
The function of this pin is selected by the SCM[0:1] bits in the MCR0 register. Refer to Section 3.2.3.2.1,
“Module Configuration Register 0 (MCR0)” for more information. The pins can be configured to provide
either high or reduced output drive.
TXD_BG[1:2] are bus driver transmit data output signals if the FlexRay Optical/Electrical PHY is
configured:
• TXD_BG1 is the output of the CC to Physical Layer Channel 1
• TXD_BG2 is the output of the CC to Physical Layer Channel 2.
TXD[1:2]_485 are bus driver transmit data output signals if the RS485 Driver type is configured:
• TXD1_485 is the output of the CC to Physical Layer Channel 1.
• TXD2_485 is the output of the CC to Physical Layer Channel 2.
MFR4200 Data Sheet, Rev. 0
40
Freescale Semiconductor
Signal Descriptions
IF_SEL1 is the CC external interface selection input signal. Refer to Table 2-1 for the selection coding.
NOTE
IF_SEL[0:1] signals are inputs during the internal reset sequence and are
latched by the internal reset signal level.
While the IF_SEL1 level is being latched, the output drive control is
disabled and the internal pulldown resistor is connected to the pin.
As IF_SEL[0:1] signals share pins with Physical Layer Interface signals,
pullup/down devices must be used for the selection. Recommended
pullup/down resistor values for the IF_SEL[0:1] inputs are given in
Section 2.4.2, “Recommended Pullup/down Resistor Values”.
2.2.3.15
TXD_BG2/TXD2_485 — PHY Transmit Data 2, RS485 Transmit Data 2
The function of this pin is selected by the SCM[0:1] bits in the MCR0 register. Refer to Section 3.2.3.2.1,
“Module Configuration Register 0 (MCR0)” for more information.
TXD_BG[1:2] are bus driver transmit data output signals if the FlexRay Optical/Electrical PHY is
configured:
• TXD_BG1 is the output of the CC to Physical Layer Channel 1.
• TXD_BG2 is the output of the CC to Physical Layer Channel 2.
TXD[1:2]_485 are bus driver transmit data output signals if the RS485 Driver type is configured:
• TXD1_485 is the output of the CC to the Physical Layer Channel 1.
• TXD2_485 is the output of the CC to the Physical Layer Channel 2.
2.2.3.16
BGEN[1:2] — Bus Guardian Enable
The CC monitors the schedule of Bus Guardians operations by checking the BGEN[1:2] input signals
provided by Bus Guardians:
BGEN1 is the input from the Physical Layer Channel 1 to the CC.
BGEN2 is the input from the Physical Layer Channel 2 to the CC.
If the RS485 Driver type is configured, the BGEN[1:2] inputs are not used and may be left open, but it is
recommended to connect these pins to the logic "0" or logic "1" level either by enabling either pullup or
pulldown resistors or by using external components. The pins can be configured to enable or disable either
pullup or pulldown resistors on the pins.
2.2.3.17
CLKOUT — Clock Output
CLKOUT is an external continuous clock output signal. The frequency of CLKOUT is selected by the
CLK_S[0:1] pins. The CLKOUT signal is always active after power-up of the CC, in all CC states
including the hard reset state. The pin can be configured to provide either high or reduced output drive.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
41
Device Overview
As the CLKOUT signal can be disabled during internal resets, refer to
Section 2.4.4, “External Output Clock” for more information on CLKOUT
generation during external hard and internal resets.
2.2.3.18
RESET# — External Reset
RESET# is an active-low control signal that acts as an input to initialize the CC to a known startup state.
2.2.3.19
INT_CC# — Interrupt Output
INT_CC# is an AMI and HCS12 interfaces interrupt request output signal. The CC may request a service
routine from the host to run. The interrupt is indicated by the logic level: it is asserted if the INT_CC#
outputs a logic "0" and negated if it outputs a logic "1".
The pin can be configured to provide either high or reduced output drive.
2.2.3.20
TEST
The TEST pin must be tied to VSS in all applications.
2.2.3.21
EXTAL/CC_CLK — Crystal Driver, External Clock Pin
This pin can act as a crystal driver pin (EXTAL) or as an external clock input pin (CC_CLK). On reset, the
device clock is derived from the input frequency on this pin. Refer to Figure 2-3 for Pierce oscillator
connections and and Figure 2-4 for external clock connections. See also Chapter 6, “Oscillator (OSCV2)”.
2.2.3.22
XTAL — Crystal Driver Pin
XTAL is a crystal driver pin. Refer to Figure 2-3 for Pierce oscillator connections and and Figure 2-4 for
external clock connections. See also Chapter 6, “Oscillator (OSCV2)”.
MFR4200
C1
EXTAL
Rb
Rs
Q
C2
XTAL
Where:
•
•
•
•
•
Q = 40 MHz crystal
Rb is in the range 1M - 10 Mohms
Rs is a lower value, which can be 0 Ohms
C1 = C2
Oscillator supply output capacitor C3 = 220 nF
Refer to crystal manufacturer’s product specification for
recommended values
VDDOSC
C3
VSSOSC
VSSOSC
VSSOSC
Figure 2-3. Pierce Oscillator Connections
MFR4200 Data Sheet, Rev. 0
42
Freescale Semiconductor
Signal Descriptions
MFR4200
EXTAL/CC_CLK
Clkout
Where:
G = 40MHz CMOS-compatible External Oscillator (VDDOSC-level)
XTAL
Not connected
(left open)
VDDOSC
C3
VSSOSC
VSSOSC
Figure 2-4. External Clock Connections
2.2.4
Power Supply Pins
MFR4200 power and ground pins are summarized in Table 2-8 and described below.
NOTE
All VSS pins must be connected together in the application.
Because fast signal transitions place high, short-duration current demands
on the power supply, use bypass capacitors with high-frequency
characteristics and place them as close to the MFR4200 as possible. Bypass
requirements depend on how heavily the MFR4200 pins are loaded.
Table 2-8. MFR4200 Power and Ground Connection Summary
Pin Number
Mnemonic
64-pin LQFP
Nominal
Voltage
VDD2_5
59
2.5V
VSS2_5
60
0V
VDDR
20
3.3V
VSSR
19
0V
VDDX[1:4]
8, 37, 54, 35
3.3V
VSSX[1:4]
9, 38, 53, 31
0V
VDDA
50
3.3V
VSSA
49
0V
VDDOSC
26
2.5V
VSSOSC
23
0V
Description
Internal power and ground generated by internal regulator
External power and ground, supply to supply to pin drivers and internal
voltage regulator.
External power and ground, supply to pin drivers.
Operating voltage and ground for the internal voltage regulator.
Provides operating voltage and ground for the internal oscillator. This
allows the supply voltage to the oscillator to be bypassed independently.
Internal power and ground generated by internal regulator.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
43
Device Overview
2.2.4.1
VDDX, VSSX — Power and Ground Pins for I/O Drivers
External power and ground for I/O drivers.
2.2.4.2
VDDR, VSSR — Power and Ground Pins for I/O Drivers and Internal
Voltage Regulator
External power and ground for I/O drivers and input to the internal voltage regulator.
NOTE
The VDDR pin enables the internal 3.3 V to 2.5 V voltage regulator. If this
pin is tied to ground, the internal voltage regulator is turned off.
2.2.4.3
VDD2_5, VSS2_5 — Core Power Pins
Power is supplied to the MFR4200 core through VDD2_5 and VSS2_5. This 2.5 V supply is derived from
the internal voltage regulator. No static load is allowed on these pins. If VDDR is tied to ground, the
internal voltage regulator is turned off.
NOTE
No load is allowed except for bypass capacitors.
2.2.4.4
VDDA, VSSA — Power Supply Pins for VREG
VDDA, VSSA are the power supply and ground input pins for the voltage regulator. They also provide the
reference voltages for the internal voltage regulator.
2.2.4.5
VDDOSC, VSSOSC — Power Supply Pins for OSC
VDDOSC, VSSOSC provide operating voltage and ground for the oscillator. This allows the supply
voltage to the oscillator to be bypassed independently. This 2.5V voltage is generated by the internal
voltage regulator.
NOTE
No load is allowed except for bypass capacitors.
2.3
System Clock Description
The internal Clock and Reset Generator block provides the internal clock signals for the FlexRay block
and all other modules. Figure 2-5 shows the clock connections from the CRG to all modules.
Refer to Chapter 5, “Clocks and Reset Generator” for detailed information on clock generation.
MFR4200 Data Sheet, Rev. 0
44
Freescale Semiconductor
System Clock Description
Host Interface
EXTAL
Receiver Channel A
CRG
oscillator clock
XTAL
Receiver Channel B
Transmitter Channel A
Transmitter Channel A
TCU
Debug Strobe
External Clock Generator
Figure 2-5. Clock Connections
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
45
Device Overview
2.4
Modes of Operation
2.4.1
Overview
The MFR4200 device operates only in one user mode — the normal mode. In normal mode, different host
interfaces can be selected, each with its own associated external pin and interface configurations. The
device has no low power modes.
2.4.2
Recommended Pullup/down Resistor Values
As IF_SEL[0:1] and CLK_S[0:1] signals share pins with physical layer interface signals, pullup/down
devices must be used for selection. Recommended pullup/down resistor values for the IF_SEL[0:1] and
CLK_S[0:1] inputs are given in Table 2-9.
Table 2-9. Recommended Pullup/down Resistor Values for IF_SEL[0:1] and CLK_S[0:1] Inputs
1
IO, Regulator, and Analog Supply Level (VDD5)
Pullup Resistor1
Pulldown Resistor1
Units
3.3V
16
47
kOhm
5V
10
47
kOhm
The listed values are calculated for the MFR4200 physical layer connection where no internal pullup/down resistors are
assumed in the Electrical PHY at the TXD_BG1, BGT, ARM and MT interface lines. If an Electrical PHY device has internal
pullup/down resistors connected to those signals, then the external pullup/down resistor values must be recalculated to
ensure that VIL requirements for pulldown resistors or VIH requirements for pullup resistors for the chosen VDD5 are met.
Refer to Section A.1.9, “I/O Characteristics” for more information on VIL, VIH and VDD5.
2.4.3
Host Controller Interfaces
The FlexRay communication controller can be connected to and controlled by microcontrollers with two
types of interface. The MCU type is selected by the IF_SEL0 and IF_SEL1 inputs as shown in
Section 2.1.3.1, “Interface Selection”.
The CC latches the values of the IF_SEL0 and IF_SEL1 signals when it leaves the hard reset state. The
CC configures the interface for the type of MCU based on the latched values. The CC latches the values
again after it has left the hard reset state (see Section 3.9.1, “Hard Reset State”).
NOTE
If the CC senses an unsupported mode on its IF_SEL pins, it stops all
internal operations, does not perform or respond to any host transactions,
stays in configuration mode, and does not integrate into the communication
process. The following steps must be taken to select a correct MCU interface
mode:
1. IF_SEL0, IF_SEL1 must be set to AMI or to HCS12 mode;
2. The hard reset signal of the CC must be asserted again.
MFR4200 Data Sheet, Rev. 0
46
Freescale Semiconductor
Modes of Operation
2.4.4
External Output Clock
The CC provides a continuous external output clock signal on the CLKOUT pin; this signal can be either
disabled or set to a frequency of 4, 10, or 40 MHz. The signal is always active after the power-up of the
CC, in all CC states including the hard reset state. The CLKOUT signal is disabled during the internal
power-on and low voltage reset procedures (refer to Chapter 5, “Clocks and Reset Generator”,
Section A.2.2, “Chip Power-up and Voltage Drops”, and the figures below (Figure 2-6, Figure 2-7, and
Figure 2-8) for more information). The CLK_S[1:0] input pins enable/disable the CLKOUT signal and
select its output frequency in accordance with the Table 2-2.
Figure 2-6 and Figure 2-7 depict the CLKOUT generation during external hard reset and internal resets.
Refer to Chapter 5, “Clocks and Reset Generator for more information.
VDD
POR
1
tUPOSC2
OSC clk output
~16000
3
Internal startup counter
0
~16000 µT
3
Internal CLK_S[1:0] latches
Latching window
3
CLKOUT divider internal reset ,
the divider is based on a counter
Max. count value defined by
CLK_S[1:0] latched values
CLKOUT divider/counter output
CLKOUT output
Where:
Counter maximum value
Counter starts counting
Counter is reset
Counter does not count
Notes:
1 For more information on the POR, refer to A.2.2, “Chip Power-up and Voltage Drops”.
2 For more information on the t
UPOSC, refer to A.3, “Reset and Oscillator”.
3
For more information on the Internal Startup Counter, the Internal CLK_S[1:0] latches, and the CLKOUT
divider internal reset signals, refer to Chapter 5, “Clocks and Reset Generator.
Figure 2-6. CLKOUT Generation During Power-on Reset
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
47
Device Overview
LVR
1
2
Internal startup counter
~16000
0
~16000 µT
2
Internal CLK_S[1:0] latches
Latching window
2
CLKOUT divider internal reset ,
the divider is based on a counter
Max. count value defined by
CLK_S[1:0] latched values
CLKOUT divider/counter output
CLKOUT output
Where:
Counter maximum value
Counter starts counting
Counter is reset
Counter does not count
Notes:
1 For more information about the POR, refer to A.2.2, “Chip Power-up and Voltage Drops.
2 For more information about the Internal Startup Counter, the Internal CLK_S[1:0] latches, and the CLKOUT
divider internal reset signals, refer to Chapter 5, “Clocks and Reset Generator.
Figure 2-7. CLKOUT Generation during Low Voltage Reset
MFR4200 Data Sheet, Rev. 0
48
Freescale Semiconductor
Modes of Operation
External Reset
RESET# pin
External reset after
1
internal glitch filter
Latching window
2
Internal CLK_S[1:0] latches
10 MHz
4 MHz
CLKOUT divider internal reset,
the divider is based on a counter
CLKOUT divider/counter output
CLKOUT output
max 8 µT
Where:
Counter maximum value
Counter starts counting
CLKOUT stabilization time
3
Counter is reset
Counter does not count
Notes:
1 Refer to Chapter 5, “Clocks and Reset Generator for more information on the reset glitch filter.
2 For example, running at 10 MHz, then switching to 4 MHz.
3 When the external hard reset signal applied to the RESET# pin is negated, the CLKOUT signal frequency
is stabilized after maximum 8 µT.
Figure 2-8. CLKOUT Generation During External Hard Reset
2.4.5
MFR4200 Connection to FlexRay Network
Figure 2-9 shows an example of connecting a FlexRay Optical/Electrical PHY to the MFR4200.
Figure 2-10 shows how to connect the RS485 transceiver to the CC.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
49
Device Overview
RXD_BG1
TXD_BG1
TXEN1
BGE1
RXD1
TXD1
Bus
Driver 1
TXEN1
BGE1
Bus
Guardian 1
MFR4200
MT
MT
BGT
BGT
ARM
ARM
BGE2
RXD_BG2
TXD_BG2
TXEN1
Bus
Guardian 2
BGE2
RXD2
Bus
Driver 2
TXD2
TXEN2
Figure 2-9. Example: Connecting a FlexRay Optical/Electrical PHY to the MFR4200
RXD1_485
TXD1_485
TXEN1_485
BGE1
MFR4200
RXD1
TXD1
RS485
Transceiver 1
TXEN1
BGE1
Not Connected
Inverter
MT
Not Connected
BGT
BGT
Not Connected
ARM
ARM
MT
BGE2
RXD2_485
TXD2_485
TXEN2_485
BGE2
Not Connected
Not Connected
RXD2
RS485
Transceiver 2
TXD2
TXEN2
Figure 2-10. Example: Connecting an RS485 PHY to the MFR4200
MFR4200 Data Sheet, Rev. 0
50
Freescale Semiconductor
Resets and Interrupts
NOTE
TXENn signals for the FlexRay Optical/Electrical PHY are multiplexed
with TXENn_485 signals for the RS485 interfaces. Therefore, additional
external inverters are required for these signals in the RS485 mode.
2.4.6
Power Mode
No power saving features are implemented in the MFR4200; the device operates only in power mode.
2.5
2.5.1
Resets and Interrupts
Overview
All possible MFR4200 internal interrupt sources are combined and provided to the host by means of one
available interrupt line: INT_CC#. Refer to Chapter 3, “MFR4200 FlexRay Communication Controller”
for more information on available interrupt sources. The type of interrupt is level sensitive.
MFR4200 has the following resets:
• external hard reset input signal RESET#.
• internal power-on and low-voltage resets provided by the internal voltage regulator (refer to
Chapter 5, “Clocks and Reset Generator” and Chapter 4, “Dual Output Voltage Regulator
(VREG3V3V2)” for more information).
2.5.2
Resets
When a reset occurs, MFR4200 registers and control bits are changed to known startup states. Refer to the
respective module chapters for register reset states for information of the different kind of resets and for
register reset states.
2.5.2.1
I/O Pins
Refer to Chapter 3, “MFR4200 FlexRay Communication Controller” for configuration of MFR4200 pins
out of reset.
2.5.3
Interrupt Sources
All interrupt sources available in the MFR4200 are controlled and indicated by the following registers:
• Interrupt status register 0 (ISR0)
• Interrupt enable register 0 (IER0)
• Startup interrupt status register (SISR)
• Startup interrupt enable register (SIER)
For more information on interrupt sources, refer to Chapter 3, “MFR4200 FlexRay Communication
Controller.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
51
Device Overview
MFR4200 Data Sheet, Rev. 0
52
Freescale Semiconductor
Chapter 3
MFR4200 FlexRay Communication Controller
3.1
Introduction
This version of the MFR4200 communication controller block guide supports MFR4200 devices with the
mask numbers 0L60X and 1L60X.
3.1.1
MFR4200 Features
The MFR4200 provides the following features.
• The FlexRay protocol according to FlexRay Protocol Working document (PWD) V1.1, with
differences described in the MFR4200 Protocol Implementation Document (PID)
• Data rate of up to 10 Mbit/s on each of two channels
• FlexRay frames with up to 254 payload bytes (padding is used for FlexRay payload data that
exceeds 32-byte data size boundary)
• One configurable receive FIFO
• Configurable counters, status indicators, and interrupts dedicated to error signalling
• Measured value indicators for clock synchronization
• The status of up to four slots can be observed independently of CC receive message buffers
• Configurable error signaling
• Fractional macroticks (MT) supported for clock correction
• 59 message buffers, each with up to 32 payload bytes
• Message buffers configurable with state or event semantics
• Each message buffer can be configured as a receive message buffer, as a transmit message buffer
(single or double), or as a part of the receive FIFO
• Receive background buffers for each channel
• The host accesses all buffers by means of three active message buffers (active transmit message
buffer, active receive message buffer and active receive FIFO buffer)
• Filtering for frame ID, cycle counter, and channel for receive and transmit message buffers
• Filtering for frame ID, channel, and message ID for the receive FIFO
• Maskable interrupt sources provided over one interrupt line
• Two types of host interface: HCS12 interface and asynchronous memory interfaces
• Minislot action point offset is configurable
• Static slot action point offset is configurable
• Hardware selectable clock output to drive external host devices: disabled/4/10/40 MHz
• Electrical physical layer interface compatible with dedicated FlexRay physical layer. Industry
standard RS485 physical layer interface also available.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
53
MFR4200 FlexRay Communication Controller
3.1.2
MFR4200 Implementation Parameters and Constraints
3.1.2.1
•
•
•
Implementation Parameters
The duration of a microtick (µT) is one CC_CLK period (25 ns at 40 MHz); a microtick starts with
a rising edge of CC_CLK.
The CC internal initialization procedure lasts for 1025 cycles of the CC_CLK clock; it starts after
leaving the hard reset state (see Section 3.9.1, “Hard Reset State”).
After the external hard reset signal on the RESET# pin is negated, the CLKOUT signal frequency
is stabilized after 8 µT.
NOTE
Refer to Section 3.8, “External 4/10 MHz Output Clock” for more
information on the CLKOUT output.
3.1.2.2
•
•
•
•
•
•
3.2
3.2.1
Implementation Constraints
The maximum external clock frequency is 40 MHz (CC_CLK).
Minislot length down to 2 µs (at CC_CLK frequency of 40 MHz) for the dynamic segment.
Minislot length is configurable (minimum 2 MT).
The maximum communication cycle length is 16 ms.
Collision avoidance symbol length is set to 30 bits.
The maximum configurable static slot length is 255 MT.
Memory Map and Registers
Introduction
This section describes the memory map, and the content and use of the registers in the host interface
module. A memory map of the CC is shown in Table 3-1.
The host accesses four types of CC registers:
• General control registers
• Buffer control, configuration, status and filtering register sets
• FIFO acceptance/rejection filter register sets
• Fifty-nine (59) configurable message buffers. The host can configure every buffer as a receive
message buffer, as a transmit message buffer (single or double), or as a FIFO receive message
buffer. All buffers are accessible through three active windows mirrored to the memory map:
— One active transmit message buffer
— One active receive message buffer
— One active FIFO buffer
MFR4200 Data Sheet, Rev. 0
54
Freescale Semiconductor
Memory Map and Registers
NOTE
The CC has two shadow receive message buffers per channel (four shadow
buffers, in total); these allow reception while the host accesses the receive
message buffers. One additional shadow message buffer is used for internal
operations. Therefore, only 59 buffers out of 64 are available to the user as
message buffers.
3.2.2
Register Map Summary
Table 3-1. Register Map Summary
Register
Description
Address
(Hex)
Address
(Dec)
Hard Reset
(Hex)
MNR
Magic Number Register
0
0
815
MVR0
Module Version Register 0
2
2
9042
MCR0
Module Configuration Register 0
4
4
8000
MCR1
Module Configuration Register 1
6
6
0
CMCVR
Current Macrotick Counter Value Register
8
8
0
CCCVR
Current Cycle Counter Value Register
0A
10
0
PSR
Protocol State Register
0C
12
0
ISR0
Interrupt Status Register 0
0E
14
0
SISR
Startup Interrupt Status Register
10
16
0
CHIER
CHI Error Register
12
18
0
IER0
Interrupt Enable Register 0
14
20
0
SIER
Startup Interrupt Enable Register
16
22
0
FSIZR
FIFO Size Register
18
24
0
FAFCHR
FIFO Acceptance/Rejection Filter Channel
Register
1A
26
0
FAFMIDVR
FIFO Acceptance Filter Message ID Value
Register
1C
28
0
FAFMIDMR
FIFO Acceptance Filter Message ID Mask
Register
1E
30
0
FRFFIDVR
FIFO Rejection Filter Frame ID Value
Register
20
32
0
FRFFIDMR
FIFO Rejection Filter Frame ID Mask
Register
22
34
0
RBIVECR
Receive Buffer Interrupt Vector Register
24
36
0
TBIVECR
Transmit Buffer Interrupt Vector Register
26
38
0
SSCIR
Slot Status Counter Incrementation Register
28
40
0
SSCIMR
Slot Status Counter Interrupt Mask Register
2A
42
0
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
55
MFR4200 FlexRay Communication Controller
Table 3-1. Register Map Summary
Register
Description
Address
(Hex)
Address
(Dec)
Hard Reset
(Hex)
2C, 2E
44, 46
0
CSECnR
Channel Status Error Counter n Register,
n=[0:1]
TICR0CS
Timer Interrupt Configuration Register 0
Cycle Set
30
48
0
TICR0MO
Timer Interrupt Configuration Register 0
Macrotick Offset
32
50
0
TICR1CS
Timer Interrupt Configuration Register 1
Cycle Set
34
52
0
TICR1MO
Timer Interrupt Configuration Register 1
Macrotick Offset
36
54
0
DBPCR
Debug Port Control Register
38
56
0
BGSR
Bus Guardian Status Register
3A
58
0
DCR
Delay Counter Register
3C
60
0
NMVLR
Network Management Vector Length
Register
3E
62
0
GNMVnR
Global Network Management Vector n
Register, n=[0:5]
GNMV0R=40
GNMV1R=42
GNMV2R=44
GNMV3R=46
GNMV4R=48
GNMV5R=4A
GNMV0R=64
GNMV1R=66
GNMV2R=68
GNMV3R=70
GNMV4R=72
GNMV5R=74
0
SSCnR
Slot Status Counter n Register, n=[0:7]
SSC0R=4C
SSC1R=4E
SSC2R=50
SSC3R=52
SSC4R=54
SSC5R=56
SSC6R=58
SSC7R=5A
SSC0R=76
SSC1R=78
SSC2R=80
SSC3R=82
SSC4R=84
SSC5R=86
SSC6R=88
SSC7R=90
0
SSCCnR
Slot Status Counter Condition n Register,
n=[0:7]
SSCC0R=5C
SSCC1R=5E
SSCC2R=60
SSCC3R=62
SSCC4R=64
SSCC5R=66
SSCC6R=68
SSCC7R=6A
SSCC0R=92
SSCC1R=94
SSCC2R=96
SSCC3R=98
SSCC4R=100
SSCC5R=102
SSCC6R=104
SSCC7R=106
0
SSSnR
Slot Status Selection n Register, n=[0:3]
SSS0R=6C
SSS1R=6E
SSS2R=70
SSS3R=72
SSS0R=108
SSS1R=110
SSS2R=112
SSS3R=114
0
MFR4200 Data Sheet, Rev. 0
56
Freescale Semiconductor
Memory Map and Registers
Table 3-1. Register Map Summary
Register
Description
Address
(Hex)
Address
(Dec)
Hard Reset
(Hex)
SS0R=74
SS1R=76
SS2R=78
SS3R=7A
SS4R=7C
SS5R=7E
SS6R=80
SS7R=82
SS0R=116
SS1R=118
SS2R=120
SS3R=122
SS4R=124
SS5R=126
SS6R=128
SS7R=130
0
SSnR
Slot Status n Register, n=[0:7]
SWCTRLR
Symbol Window Control Register
84
132
0
SWSAR
Symbol Window Status channel A Register
86
134
0
SWSBR
Symbol Window Status channel B Register
88
136
0
WMCTRLR
Wakeup Mechanism Control Register
8A
138
0
NSSR
Number of Static Slots Register
8E
142
1
SPLR
Static Payload Length Register
90
144
0
MPLDR
Maximum Payload Length Dynamic
Register
92
146
0
SYNCFR
Sync Frame Register
94
148
0
SYNCHR
Sync Frame Header Register
96
150
undefined
MVR1
Module Version Register 1
98
152
For mask set
number:
0L60X – 0;
1L60X – 0001
HIPDSR
Host Interface Pins Drive Strength Register
9A
154
0
PLPDSR
Physical Layer Pins Drive Strength Register
9C
156
0
HIPPER
Host Interface Pins Pullup/down Enable
Register
9E
158
0
HIPPCR
Host Interface Pins Pullup/down Control
Register
A0
160
0
PLPPER
Physical Layer Pins Pullup/down Enable
Register
A2
162
0
PLPPCR
Physical Layer Pins Pullup/down Control
Register
A4
164
0
VREGSR
Voltage Regulator Status Register
A6
166
0
BDR
Bit Duration Register
A8
168
undefined
IDLR
Idle Detection Length Register
AA
170
undefined
NMLR
Nominal Macrotick Length Register
AC
172
undefined
BGTR
Bus Guardian Tick Register
AE
174
undefined
SSLR
Static Slot Length Register
B0
176
undefined
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
57
MFR4200 FlexRay Communication Controller
Table 3-1. Register Map Summary
Register
Description
Address
(Hex)
Address
(Dec)
Hard Reset
(Hex)
CLR
Cycle Length Register
B2
178
undefined
MPCLR
Microticks per Cycle Low Register
B4
180
undefined
MPCHR
Microticks per Cycle High Register
B6
182
undefined
MCLDAR
Maximum Cycle Length Deviation Register
B8
184
undefined
TSSLR
Transmit Start Sequence Length Register
BA
186
undefined
SWCR
Symbol Window Configuration Register
BC
188
undefined
NITCR
Network Idle Time Configuration Register
BE
190
undefined
CSMR
Coldstart Maximum Register
C0
192
undefined
MSFR
Maximum Sync Frames Register
C2
194
undefined
LDTSR
Latest Dynamic Transmission Start Register
C4
196
undefined
MSLR
Minislot Length Register
C6
198
undefined
MSAPOR
Minislot Action Point Offset Register
C8
200
undefined
SSAPOR
Static Slot Action Point Offset Register
CA
202
undefined
MOCWCFR
Maximum Odd Cycles Without Clock
Correction Fatal Register
CC
204
undefined
DCAR
Delay Compensation Channel A Register
D0
208
undefined
DCBR
Delay Compensation Channel B Register
D2
210
undefined
LNLR
Listen timeout with Noise Length Register
D6
214
undefined
MOCWCPR
Maximum Odd Cycles Without clock
Correction Passive Register
D8
216
undefined
MOCR
Maximum Offset Correction Register
DA
218
undefined
MRCR
Maximum Rate Correction Register
DC
220
undefined
CDDR
Cluster Drift Damping Register
DE
222
undefined
SOCCTR
Start of Offset Correction Cycle Time
Register
E0
224
undefined
WUSTXIR
Wakeup Symbol TX Idle Register
EA
234
0
WUSTXLR
Wakeup Symbol TX Low Register
EC
236
0
SYNFAFMR
Sync Frame Acceptance Filter Mask
Register
EE
238
undefined
SYNFAFVR
Sync Frame Acceptance Filter Value
Register
F0
240
undefined
SYNFRFR
Sync Frame Rejection Filter Register
F2
242
undefined
EOCR
External Offset Correction Register
F4
244
undefined
ERCR
External Rate Correction Register
F6
246
undefined
MFR4200 Data Sheet, Rev. 0
58
Freescale Semiconductor
Memory Map and Registers
Table 3-1. Register Map Summary
Register
Description
Address
(Hex)
Address
(Dec)
Hard Reset
(Hex)
ECCR
External Correction Control Register
F8
248
undefined
AFBFRID
Active FIFO Buffer Frame ID Register
100
256
undefined
AFBCCPLR
Active FIFO Buffer Cycle Counter and
Payload Length Register
102
258
undefined
AFBCRCR
Active FIFO Buffer Header CRC Register
104
260
undefined
AFBDATAnR
Active FIFO Buffer Data n Register, n=[0:15]
AFBMBSSVR
Active FIFO Buffer Message Buffer Slot
Status Vector Register
126
294
undefined
ARBFRID
Active Receive Buffer Frame ID Register
140
320
undefined
ARBCCPLR
Active Receive Buffer Cycle Counter and
Payload Length Register
142
322
undefined
ARBCRCR
Active Receive Buffer Header CRC Register
144
324
undefined
ARBDATAnR
Active Receive Buffer Data n Register,
n=[0:15]
ARBDATA0R=146
…
ARBDATA15R=164
ARBDATA0R=326
…
ARBDATA15R=356
undefined
ARBMBSSVR
Active Receive Buffer Message Buffer Slot
Status Vector Register
166
358
undefined
ATBFRID
Active Transmit Buffer Frame ID Register
180
384
undefined
ATBCCPLR
Active Transmit Buffer Cycle Counter and
Payload Length Register
182
386
undefined
ATBCRCR
Active Transmit Buffer Header CRC Register
184
388
undefined
ATBDATAnR
Active Transmit Buffer Data n Register,
n=[0:15]
ATBDATA0R=186
…
ATBDATA15R=1A4
ATBDATA0R=390
…
ATBDATA15R=420
undefined
ATBMBSSVR
Active Transmit Buffer Message Buffer Slot
Status Vector Register
1A6
422
undefined
BUFCSnR
Message Buffer Control, Configuration and
Status n Register, n=[0:58]
BUFCS0R=200
BUFCS1R=204
…
BUFCS57R=2E4
BUFCS58R=2E8
BUFCS0R=512
BUFCS1R=516
…
BUFCS57R=740
BUFCS58R=744
IFLG, IENA,
CFG and VALID
bits are reset to
0; others are
undefined
CCFnR
Cycle Counter Filter n Register, n=[0:58]
CCF0R=202
CCF1R=206
…
CCF57R=2E6
CCF58R=2EA.
CCF0R=514
CCF1R=518
…
CCF57R=742
CCF58R=746
undefined
CCFCR
Clock Correction Failed Counter Register
326
806
undefined
EHLR
Error Handling Level Register
328
808
undefined
ARFBDATA0R=106 ARFBDATA0R=262
…
…
ARFBDATA15R=124 ARFBDATA15R=292
undefined
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
59
MFR4200 FlexRay Communication Controller
Table 3-1. Register Map Summary
Register
Description
Address
(Hex)
Address
(Dec)
Hard Reset
(Hex)
RCVR
Rate Correction Value Register
32A
810
undefined
OCVR
Offset Correction Value Register
32C
812
undefined
EMCR
Even Measurement Counter Register
33C
828
undefined
OMCR
Odd Measurement Counter Register
33E
830
undefined
EMAnR
Even Measurement channel A n Register,
n=[0:15]
EMA0R=340
…
EMA15R=35E
EMA0R=832
…
EMA15R=862
undefined
EMBnR
Even Measurement channel B n Register,
n=[0:15]
EMB0R=360
…
EMB15R=37E
EMB0R=864
…
EMB15R=894
undefined
ESFIDnR
Even Sync ID n Register, n=[0:15]
EID0R=380
…
EID15R=39E
EID0R=896
…
EID15R=926
undefined
OMAnR
Odd Measurement channel A n Register,
n=[0:15]
OMA0R=3A0
…
OMA15R=3BE
OMA0R=928
…
OMA15R=958
undefined
OMBnR
Odd Measurement channel B n Register,
n=[0:15]
OMB0R=3C0
…
OMB15R=3DE
OMB0R=960
…
OMB15R=990
undefined
OSFIDnR
Odd Sync Frame ID n Register, n=[0:15]
OSFID0R=3E0
…
OSFID15R=3FE
OSFID0R=1008
…
OSFID15R=1022
undefined
3.2.3
Register Descriptions
A condensed overview of all registers is provided in Section 3.2.2, “Register Map Summary”
•
•
•
•
•
NOTE
All registers not shown in the CC memory map registers are not
implemented in hardware.
Any read operation on bits marked as ‘Reserved’ will return an
undefined value (either ‘1’ or ‘0’).
The host must take care that bits marked as ‘Reserved’ are set to 0 when
writing.
The reset value indicated for each register is the value that the register
has after a hard reset operation.
Meaning of the bit field character in the registers layout:
– ‘r’ indicates that the bit-field may be read by host
– ‘w’ denotes that the bit-field may be updated by host
– ‘h’ means that the bit-field is updated by the communication controller
MFR4200 Data Sheet, Rev. 0
60
Freescale Semiconductor
Memory Map and Registers
•
Combinations such as ‘rh’, ‘rw’ or ‘rwh’ appear in the text indicating
the different access possibilities.
An additional asterisk ‘*’ indicates an exceptional behavior, i.e. under
which conditions the host is allowed to write a ‘rw’ or ‘rwh’ bit-field,
etc. In such cases, refer to the detailed bit-field description.
Descriptions of configuration registers specify the possible range of
values in square brackets – [,].
•
•
NOTE
The configuration registers’ possible ranges of values, specified in square
brackets [ : ], denote only the MFR4200 implementation constraints. Not
every configuration supported by the MFR4200 implementation is
necessarily a valid configuration of an application network. For more
information about configuration constraints, refer to the PWD:
Configuration Constraints Notations chapter.
A key to the register diagrams is shown in Figure 3-1.
Section Number
Register Full Name
Register Short Name
FlexRay Protocol
Related Parameter
3.2.3.3.1
Bit Duration Register (BDR)
FlexRay Protocol Related Parameter – gdBit
Address0xA8
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
BD6
BD5
BD4
BD3
BD2
BD1
BD0
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Register
Address
Register Reset
Value/State
Bit Number
Bit Access
Scheme
Bit Name
Figure 3-1. Key to Register Diagrams
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
61
MFR4200 FlexRay Communication Controller
3.2.3.1
Controller’s Constants Registers
3.2.3.1.1
Module Version Register 0 (MVR0)
Address 0x2
Reset 0x9042
15
14
13
12
11
10
9
8
MJFR3
MJFR2
MJFR1
MJFR0
MINFR3
MINFR2
MINFR1
MINFR0
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
PDA7
PDA6
PDA5
PDA4
PDA3
PDA2
PDA1
PDA0
r
r
r
r
r
r
r
r
Figure 3-2. Module Version Register 0
The read-only MVR0, together with MVR1 (see following section), holds the version number of the
implementation. The MVR0 contains the following fields:
PDA[0:7] denotes the device PartID1.
MINFR[0:3] denotes the minor release of the FlexRay core in the MFR4200 device.
MJFR[0:3] denotes the major release of the FlexRay core in the MFR4200 device.
3.2.3.1.2
Module Version Register 1 (MVR1)
Address 0x98
Reset
Device
Mask Set Number
Reset Value
MFR4200
0L60X
0x0000
MFR4200
1L60X
0x0001
15
14
13
12
11
10
9
8
PDB7
PDB6
PDB5
PDB4
PDB3
PDB2
PDB1
PDB0
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
MJMR3
MJMR2
MJMR1
MJMR0
MINMR3
MINMR2
MINMR1
MINMR0
r
r
r
r
r
r
r
r
Figure 3-3. Module Version Register 1
The read-only MVR1, together with MVR0 (see previous section), holds the version number of the
implementation. The MVR1 contains:
MFR4200 Data Sheet, Rev. 0
62
Freescale Semiconductor
Memory Map and Registers
PDB[0:7] denotes the device PartID2.
MINMR[0:3] denotes the minor release of the MFR4200 device.
MJMR[0:3] denotes the major release of the MFR4200 device.
3.2.3.1.3
Magic Number Register (MNR)
Address 0x0
Reset 0x0815
15
14
13
12
11
10
9
8
MN15
MN14
MN13
MN12
MN11
MN10
MN9
MN8
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
MN7
MN6
MN5
MN4
MN3
MN2
MN1
MN0
r
r
r
r
r
r
r
r
Figure 3-4. Magic Number Register
This read-only register contains the arbitrary value 0x0815; it is used for endianess and memory map
address offset checks.
NOTE
The MNR contains 0x0000 while the controller is initializing after leaving
the hard reset state. Only after this initialization is completed, does it contain
the value 0x0815. After the controller leaves the hard reset state, the host
must wait until the initialization is completed before reading or writing to
the controller. The initialization takes 1025 cycles (CC_CLK) after
de-assertion of the hard reset.
During the internal initialization procedure time, the host must not access
any CC register except MNR (see Section 3.2.3.1.3, “Magic Number
Register (MNR)”), which acknowledges the completion of the internal
initialization procedure.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
63
MFR4200 FlexRay Communication Controller
3.2.3.2
Configuration Registers
3.2.3.2.1
Module Configuration Register 0 (MCR0)
Address 0x4
Reset 0x8000
15
14
13
12
11
10
9
8
CONFIG
Reserved
Reserved
Reserved
Reserved
Reserved
CBE
CAE
rwh
r
r
r
r
r
rw*
rw*
7
6
5
4
3
2
1
0
Reserved
ENSYNFF
NSYNC
SCM1
SCM0
Reserved
DIAGSTOP
Reserved
r
rw*
rh
rw*
rw*
r
rw
r
Figure 3-5. Module Configuration Register 0
NOTE
Setting the CONFIG bit and writing to other bits in this register can be done
in separate instructions only. Trying to set CONFIG and change other bits at
the same time will change CONFIG only — the other bits will not be
changed. Clearing CONFIG and writing to other bits in the MCR0 can be
done simultaneously in one instruction.
DIAGSTOP — Diagnosis Stop State Bit
When this bit is set by the host, the CC immediately enters the Diagnosis Stop state. Any ongoing
transmission or reception is aborted, and synchronization with the FlexRay communication bus is lost.
When this bit is cleared by the host, the controller enters the configuration state.
1 – The CC is in the Diagnosis Stop state.
0 – The CC is not in the Diagnosis Stop state.
SCM0, SCM1 — Serial Communication Mode Bits 0 and 1
These bits define the type of bus driver connected to the controller. It can be written during the
configuration state only.
Table 3-2. Bus Driver Type Selection
Driver type
SCM1
SCM0
RS485 (IDLE state coded as “0”)
0
0
Optical/Electrical PHY
0
1
—
1
0
RS485 (IDLE state coded as “1”)
1
1
MFR4200 Data Sheet, Rev. 0
64
Freescale Semiconductor
Memory Map and Registers
NOTE
It is not possible to mix different RS485’s in a cluster or per channel, or to
mix RS485 and Optical/Electrical PHY.
NSYNC — Node Synchronized
This read-only bit is set when the controller enters the normal state in the course of startup or reintegration.
The NSYNC is set by the CC in the NIT preceding a transition to normal operation. The NSYNC is cleared
by the CC in the NIT, prior to switching to the normal passive state (the ‘yellow’ error state; see
Section 3.2.3.6.5, “Error Handling Level Register (EHLR)”) or the Diagnosis Stop state (the ‘red’ error
state; see Section 3.2.3.6.5, “Error Handling Level Register (EHLR)”), due to…
• …the correction value exceeding MRCR (see Section 3.2.3.3.25, “Maximum Rate Correction
Register (MRCR)”)
• …the offset correction value exceeding MOCR (see Section 3.2.3.3.24, “Maximum Offset
Correction Register (MOCR)”)
• …the CCFCR value (see Section 3.2.3.6.4, “Clock Correction Failed Counter Register (CCFCR)”)
exceeding MOCWCPR (see Section 3.2.3.5.3, “Maximum Odd Cycles Without clock Correction
Passive Register (MOCWCPR)”) or MOCWCFR (see Section 3.2.3.5.2, “Maximum Odd Cycles
Without Clock Correction Fatal Register (MOCWCFR)).
1 – Node is synchronized to cluster.
0 – Node is not synchronized to cluster.
ENSYNFF — Enable Sync Frame Filters
This bit enables/disables acceptance and rejection filtering for sync frames (see Section 3.2.3.8.1, “Sync
Frame Acceptance Filter Value Register (SYNFAFVR)”, Section 3.2.3.8.2, “Sync Frame Acceptance
Filter Mask Register (SYNFAFMR)” and Section 3.2.3.8.3, “Sync Frame Rejection Filter Register
(SYNFRFR)”).
1 – Sync frames are used for the clock synchronization only when they pass the acceptance filter and are
not rejected by the rejection filter.
0 – Sync frames are used for the clock synchronization independently of the acceptance and rejection filter.
CAE — Channel A Enable
This bit enables channel A. It can be written during the configuration state only.
1 – Channel A is enabled.
0 – Channel A is disabled.
CBE — Channel B Enable
This bit enables channel B. It can be written during the configuration state only.
1 – Channel B is enabled.
0 – Channel B disabled.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
65
MFR4200 FlexRay Communication Controller
CONFIG — Configuration State Bit
When the host sets this bit, the CC immediately enters the configuration state. The controller aborts any
ongoing transmission or reception and abandons synchronization to the FlexRay cluster. When the host
clears this bit, the controller resumes normal operation (see Section 3.9.2, “Configuration State”). After a
hard reset, the controller automatically enters the configuration state (CONFIG bit set).
1 – Configuration state.
0 – Normal operation.
3.2.3.2.2
Module Configuration Register 1 (MCR1)
Address 0x6
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
AYTG
ARL
CSI
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
Reserved
ECSE
BGSMDSE
BGSMSWE
Reserved
MATE
Reserved
Reserved
r
rw*
rw*
rw*
r
rw*
r
r
Figure 3-6. Module Configuration Register 1
MATE — Media Access Test Enable
This flag enables the media access test in the MFR4200 bus guardian (BG) monitor. This flag may be
written in the configuration state only.
1 – Media access test is enabled.
0 – Media access test is disabled.
BGSMSWE — BG Schedule Monitoring Symbol Window Enable
This flag determines the behavior of the MFR4200 bus guardian schedule monitor during the symbol
window. It may be written in the configuration state only.
1 – BG is expected to be open during symbol window of the communication cycle.
0 – BG is expected to be closed during symbol window of the communication cycle.
BGSMDSE — BG Schedule Monitoring Dynamic Segment Enable
This flag determines the behavior of the MFR4200 bus guardian monitor during the dynamic segment of
the communication cycle. It may be written in the configuration state only.
1 – BG expected to be open during dynamic segment of the communication cycle.
0 – BG expected to be closed during dynamic segment of the communication cycle.
MFR4200 Data Sheet, Rev. 0
66
Freescale Semiconductor
Memory Map and Registers
ECSE — External Clock Synchronization Enable
This configuration flag enables/disables the External Clock Synchronization. It can be written during the
configuration state only.
1 – External Clock Synchronization is enabled.
0 – External Clock Synchronization is disabled.
CSI — Coldstart Inhibit Mode
The node can be prevented from initializing the TDMA communication schedule by setting the CSI bit to
‘1’ in the configuration state. It can be written during the configuration state only.
1 – Node is in Coldstart Inhibit mode.
0 – Node is not in Coldstart Inhibit mode.
ARL — Allow Red Level
If this bit is set, the transition to the red error handling level (Diagnosis Stop state) due to clock sync errors
is allowed. It may be written in the configuration state only.
1 – Error handling level red is allowed (the CC enters the Diagnosis Stop state).
0 – Error handling level red is prohibited (the CC enters the configuration state).
AYTG — Allow Yellow to Green
If this bit is set, the transition from the yellow error handling level to the green error handling level is
allowed. It may be written in the configuration state only.
1 – Transition from yellow to green is allowed.
0 – Transition from yellow to green is prohibited.
3.2.3.2.3
Host Interface and Physical Layer Pins Drive Strength Register (HIPDSR)
Address 0x9A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
INT_CC#
CLKOUT
ARM/DBG1/
CLK_S0
MT/CLK_S1
BGT/DBG2/
IF_SEL0
PAD[0:15]/
D[15:0]
r
r
rw
rw
rw
rw
rw
rw
Figure 3-7. Host Interface Pins Drive Strength Register
This register controls the drive strength of the MFR4200 pins identified in Figure 3-7.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
67
MFR4200 FlexRay Communication Controller
1 – Pin drive strength is partial (see Appendix A.1.9, “I/O Characteristics”).
0 – Pin drive strength is full (see Appendix A.1.9, “I/O Characteristics”).
3.2.3.2.4
Physical Layer Pins Drive Strength Register (PLPDSR)
Address 0x9C
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
TXD_BG2/
TXD2_485
TXD_BG1/
TXD1_485/
IF_SEL1
TXEN2#/
TXE2_485#
TXEN1#/
TXE1_485#
r
r
r
r
rw
rw
rw
rw
Figure 3-8. Physical Layer Pins Drive Strength Register
This register controls the drive strength of the MFR4200 pins identified in Figure 3-8.
1 – Pin drive strength is partial (see Section A.1.9, “I/O Characteristics”).
0 – Pin drive strength is full (see Section A.1.9, “I/O Characteristics”).
3.2.3.2.5
Host Interface Pins Pullup/down Enable Register (HIPPER)
Address 0x9E
Reset 0x0
15
14
13
12
11
10
9
8
ECLK_CC
WE#/
RW_CC#
CE#/LSTRB
D[15:0]/
PAD[0:15]
ACS5
ACS4
OE#/ACS3
A9/ACS2
rw
rw
rw
rw
rw
rw
rw
rw
7
6
5
4
3
2
1
0
A8/ACS1
A7/ACS0
A6/
XADDR14
A5/
XADDR15
A4/
XADDR16
A3/
XADDR17
A2/
XADDR18
A1/
XADDR19
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-9. Host Interface Pins Pullup/down Enable Register
This register enables the pullups and pulldowns on MFR4200 pins identified in Figure 3-9. The
pullup/down state is controlled by the HIPPCR (see Section 3.2.3.2.6, “Host Interface Pins Pullup/down
Control Register (HIPPCR)”).
1 – Pullup/down resistor enabled.
MFR4200 Data Sheet, Rev. 0
68
Freescale Semiconductor
Memory Map and Registers
0 – Pullup/down resistor disabled.
3.2.3.2.6
Host Interface Pins Pullup/down Control Register (HIPPCR)
Address 0xA0
Reset 0x0
15
14
13
12
11
10
9
8
ECLK_CC
WE#/
RW_CC#
CE#/LSTRB
D[15:0]/
PAD[0:15]
ACS5
ACS4
OE#/ACS3
A9/ACS2
rw
rw
rw
rw
rw
rw
rw
rw
7
6
5
4
3
2
1
0
A8/ACS1
A7/ACS0
A6/
XADDR14
A5/
XADDR15
A4/
XADDR16
A3/
XADDR17
A2/
XADDR18
A1/
XADDR19
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-10. Host Interface Pins Pullup/down Control Register
This register controls the pullups and pulldowns on MFR4200 pins identified in Figure 3-10. These
functions can be enabled/disabled by the HIPPER (see Section 3.2.3.2.5, “Host Interface Pins Pullup/down
Enable Register (HIPPER)”).
1 – Pullup selected.
0 – Pulldown selected.
3.2.3.2.7
Physical Layer Pins Pullup/down Enable Register (PLPPER)
Address 0xA2
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
BGEN2
BGEN1
RXD_BG2/
RXD2_485
RXD_BG1/RX
D1_485
r
r
r
r
rw
rw
rw
rw
Figure 3-11. Physical Layer Pins Pullup/down Enable Register
This register enables the pullups and pulldowns on MFR4200 pins identified in Figure 3-11. The
pullup/down state is controlled by the PLPPCR (see Section 3.2.3.2.8, “Physical Layer Pins Pullup/down
Control Register (PLPPCR)”).
1 – Pullup/down enabled.
0 – Pullup/down disabled.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
69
MFR4200 FlexRay Communication Controller
3.2.3.2.8
Physical Layer Pins Pullup/down Control Register (PLPPCR)
Address 0xA4
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
BGEN2
BGEN1
RXD_BG2/
RXD2_485
RXD_BG1/RX
D1_485
r
r
r
r
rw
rw
rw
rw
Figure 3-12. Physical Layer Pins Pullup/down Control Register
This register controls the pullups and pulldowns on MFR4200 pins identified in Figure 3-12. These
function can be enabled/disabled by the PLPPER (see Section 3.2.3.2.7, “Physical Layer Pins Pullup/down
Enable Register (PLPPER)”).
1 – Pullup selected.
0 – Pulldown selected.
3.2.3.2.9
Voltage Regulator Status Register (VREGSR)
Address 0xA6
Reset
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Low-voltage
Status
Power-on
Status
r
r
r
r
r
r
rwh
rwh
Figure 3-13. Voltage Regulator Status Register
This register indicates the occurrence of internal low-voltage and/or power-on reset events caused by
power-on of MFR4200 device or supply voltage disturbances. The Low-voltage Status and Power-on
Status bits do not cause an interrupt over the INT_CC# pin; therefore, the host may read this register to
check the status.
The host clears any status bit in VREGSR by reading VREGSR. The CC sets a status bit in the VREGSR
again when it detects the condition for that bit.
MFR4200 Data Sheet, Rev. 0
70
Freescale Semiconductor
Memory Map and Registers
Low-voltage Status, Power-on Status
1 – MFR4200 has been reset internally due to reset conditions sensed by the voltage regulator.
0 – MFR4200 has not been reset internally.
NOTE
Low-voltage and power-on events generated by the MFR4200 voltage
regulator cause the internal MFR4200 reset with the same consequences as
in the case of an external hard reset. Therefore, changes to the VREGSR bits
can be read by the host only after the MFR4200 leaves the internal reset
state.
3.2.3.3
3.2.3.3.1
Control Registers
Bit Duration Register (BDR)
FlexRay Protocol Related Parameter – gdBit
Address 0xA8
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
BD6
BD5
BD4
BD3
BD2
BD1
BD0
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-14. Bit Duration Register
This register controls the number of microticks per bit. Writing this register is possible only during the
configuration state.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
71
MFR4200 FlexRay Communication Controller
3.2.3.3.2
Delay Compensation Channel A Register (DCAR)
FlexRay Protocol Related Parameter – pDelayCompensation[A]
Address 0xD0
Reset undefined state
15
14
13
12
11
10
9
8
DCA15
DCA14
DCA13
DCA12
DCA11
DCA10
DCA9
DCA8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
DCA7
DCA6
DCA5
DCA4
DCA3
DCA2
DCA1
DCA0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-15. Delay Compensation Channel A Register
This register holds the value used to compensate for reception delays on channel A in microticks. The
register can be written during the configuration state only. The value of this register must be within the
range [0:127].
3.2.3.3.3
Delay Compensation Channel B Register (DCBR)
FlexRay Protocol Related Parameter – pDelayCompensation[B]
Address 0xD2
Reset undefined state
15
14
13
12
11
10
9
8
DCB15
DCB14
DCB13
DCB12
DCB11
DCB10
DCB9
DCB8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
DCB7
DCB6
DCB5
DCB4
DCB3
DCB2
DCB1
DCB0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-16. Delay Compensation Channel B Register
This register holds the value used to compensate for reception delays on channel B in microticks. The
register can be written during the configuration state only. The value of this register must be within the
range [0:127].
MFR4200 Data Sheet, Rev. 0
72
Freescale Semiconductor
Memory Map and Registers
3.2.3.3.4
Cluster Drift Damping Register (CDDR)
FlexRay Protocol Related Parameter – pClusterDriftDamping
Address 0xDE
Reset undefined state
15
14
13
12
11
10
9
8
CDD15
CDD14
CDD13
CDD12
CDD11
CDD10
CDD9
CDD8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
CDD7
CDD6
CDD5
CDD4
CDD3
CDD2
CDD1
CDD0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-17. Cluster Drift Damping Register
This register defines the value used, in clock synchronization, to minimize the accumulation of rounding
errors. This register can be written in the configuration state only. The register value is given in microticks
and must be within the range [1:15].
3.2.3.3.5
Maximum Sync Frames Register (MSFR)
FlexRay Protocol Related Parameter – gSyncNodeMax
Address 0xC2
Reset undefined state
15
14
13
12
11
10
9
8
MSF15
MSF14
MSF13
MSF12
MSF11
MSF10
MSF9
MSF8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
MSF7
MSF6
MSF5
MSF4
MSF3
MSF2
MSF1
MSF0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-18. Maximum Sync Frames Register
This register holds the maximum number of sync frames that can be transmitted on either channel in a
network, including a node’s own sync frame. The host may modify this register in the configuration state
only. The value of this register must be within the range [2:15].
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
73
MFR4200 FlexRay Communication Controller
3.2.3.3.6
Nominal Macrotick Length Register (NMLR)
FlexRay Protocol Related Parameter – pMicroPerMacroNom
Address 0xAC
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
NML7
NML6
NML5
NML4
NML3
NML2
NML1
NML0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-19. Nominal Macrotick Length Register
This register defines the integer number of microticks per nominal macrotick, according to Equation 3-1.
NMLR = int (cycle length in µT / CLR)
Eqn. 3-1
Writing this register is possible only in the configuration state.
3.2.3.3.7
Microticks Per Cycle Low Register (MPCLR)
Address 0xB4
Reset undefined state
15
14
13
12
11
10
9
8
MPCL15
MPCL14
MPCL13
MPCL12
MPCL11
MPCL10
MPCL9
MPCL8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
MPCL7
MPCL6
MPCL5
MPCL4
MPCL3
MPCL2
MPCL1
MPCL0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-20. Microticks Per Cycle Low Register
The MPCHR and MPCLR are described in the following section.
The MPCLR can be written during the configuration state only.
MFR4200 Data Sheet, Rev. 0
74
Freescale Semiconductor
Memory Map and Registers
3.2.3.3.8
Microticks Per Cycle High Register (MPCHR)
Address 0xB6
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
MPCH7
MPCH6
MPCH5
MPCH4
MPCH3
MPCH2
MPCH1
MPCH0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-21. Microticks Per Cycle High Register
The MPCHR and MPCLR define the number of microticks per cycle. Writing these registers is possible
only in the configuration state. The relationship between registers MPCHR, MPCLR, and CLR is given by
Equation 3-2.
MPCHR * 2^16 + MPCLR = (Cycle Length) – k * CLR
Eqn. 3-2
Where:
• Cycle Length = the length of a communication cycle in microticks
• k = 1 [microtick/macrotick]
3.2.3.3.9
Static Slot Length Register (SSLR)
FlexRay Protocol Related Parameter – gdStaticSlot
Address 0xB0
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
SSL7
SSL6
SSL5
SSL4
SSL3
SSL2
SSL1
SSL0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-22. Static Slot Length Register
This register defines the number of macroticks per slot. Writing this register is possible only in the
configuration state.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
75
MFR4200 FlexRay Communication Controller
3.2.3.3.10
Number of Static Slots Register (NSSR)
FlexRay Protocol Related Parameter – gNumberOfStaticSlots
Address 0x8E
Reset 0x1
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
NSS10
NSS9
NSS8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
NSS7
NSS6
NSS5
NSS4
NSS3
NSS2
NSS1
NSS0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-23. Number of Static Slots Register
This register defines the number of static slots in a cycle. Writing this register is possible only during the
configuration state.
NOTE
The range of possible values for the NSSR is from 0x2 to 0x3FF. This means
that at least two static slots must be programmed.
3.2.3.3.11
Static Payload Length Register (SPLR)
FlexRay Protocol Related Parameter – gPayloadLengthStatic
Address 0x90
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
SPL6
SPL5
SPL4
SPL3
SPL2
SPL1
SPL0
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-24. Static Payload Length Register
This register defines the maximum data length for static frames in words (1 word = 2 bytes). Writing this
register is possible only during the configuration state.
MFR4200 Data Sheet, Rev. 0
76
Freescale Semiconductor
Memory Map and Registers
3.2.3.3.12
Minislot Length Register (MSLR)
FlexRay Protocol Related Parameter – gdMinislot
Address 0xC6
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
MSL6
MSL5
MSL4
MSL3
MSL2
MSL1
MSL0
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-25. Minislot Length Register
This register defines the minislot length in macroticks. The register can be written during the configuration
state only. The value of this register must be within the range [2:63].
3.2.3.3.13
Minislot Action Point Offset Register (MSAPOR)
FlexRay Protocol Related Parameter – gdMinislotActionPointOffset
Address 0xC8
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
MSAPO3
MSAPO2
MSAPO1
MSAPO0
r
r
r
r
rw*
rw*
rw*
rw*
Figure 3-26. Minislot Action Point Offset Register
This register defines the offset of the action point within the minislot in macroticks. The register can be
written during the configuration state only. The value of this register must be within the range [1:15].
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
77
MFR4200 FlexRay Communication Controller
3.2.3.3.14
Static Slot Action Point Offset Register (SSAPOR)
FlexRay Protocol Related Parameter – gdActionPointOffset
Address 0xCA
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
SSAPO3
SSAPO2
SSAPO1
SSAPO0
r
r
r
r
rw*
rw*
rw*
rw*
Figure 3-27. Static Slot Action Point Offset Register
This register defines the offset of the action point in macroticks. The register can be written only during
the configuration state. The value of this register must be within the range [1:15].
3.2.3.3.15
Latest Dynamic Transmission Start Register (LDTSR)
FlexRay Protocol Related Parameter – pLatestTx
Address 0xC4
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
LDT13
LDT12
LDT11
LDT10
LDT9
LDT8
r
r
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
LDT7
LDT6
LDT5
LDT4
LDT3
LDT2
LDT1
LDT0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-28. Latest Dynamic Transmission Start Register
This register defines the cycle time after which dynamic frame transmission can start. If the cycle time is
greater than this register’s value, the controller continues an ongoing dynamic frame transmission (started
before this point in time) and does not start any new dynamic frame transmissions. The latest dynamic
transmission start is expressed in macroticks. The register can be written only in the configuration state.
MFR4200 Data Sheet, Rev. 0
78
Freescale Semiconductor
Memory Map and Registers
3.2.3.3.16
Maximum Payload Length Dynamic Register (MPLDR)
FlexRay Protocol Related Parameter – gMaxPayloadLengthDynamic
Address 0x92
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
MPLD6*
MPLD5*
MPLD4*
MPLD3*
MPLD2*
MPLD1*
MPLD0*
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-29. Maximum Payload Length Dynamic Register
This register defines the maximum payload length in the dynamic segment, in terms of words
(1 word = 2 bytes). This register can be written only during the configuration state.
NOTE
The value of the maximum payload length dynamic register is used for
checking transmit message buffers (see the MDPLE bit description in
Section 3.2.3.6.3, “CHI Error Register (CHIER)” and Section 3.3.2.7,
“LEN[6: 0] — Payload Length”).
3.2.3.3.17
Symbol Window Configuration Register (SWCR)
FlexRay Protocol Related Parameter – gdSymbolWindow
Address 0xBC
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
SWC13
SWC12
SWC11
SWC10
SWC9
SWC8
r
r
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
SWC7
SWC6
SWC5
SWC4
SWC3
SWC2
SWC1
SWC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-30. Symbol Window Configuration Register
This register defines the cycle time in which the symbol window starts. The cycle time is measured in
macroticks. This register may be modified only in the configuration state.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
79
MFR4200 FlexRay Communication Controller
3.2.3.3.18
Network Idle Time Configuration Register (NITCR)
FlexRay Protocol Related Parameter – gdNIT
Address 0xBE
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
NITC13
NITC12
NITC11
NITC10
NITC9
NITC8
r
r
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
NITC7
NITC6
NITC5
NITC4
NITC3
NITC2
NITC1
NITC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-31. Network Idle Time Configuration Register
This register defines the cycle time in which the network idle time starts. The cycle time is measured in
macroticks. The register may be modified in the configuration state only. This register is related to the
SOCCTR register (refer to the note in Section 3.2.3.3.34, “Start of Offset Correction Cycle Time Register
(SOCCTR)”).
NOTE
Since the duration of the NIT must be longer than or equal to
ceil ((1300µT + 170µT * MSFR)/NMLR) + 1 [nominal MT],
Eqn. 3-3
this register must be configured to, at most
CLR - NIT duration [nominal MT]
3.2.3.3.19
Eqn. 3-4
Cycle Length Register (CLR)
FlexRay Protocol Related Parameter – gMacroPerCycle
Address 0xB2
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
CL13
CL12
CL11
CL10
CL9
CL8
r
r
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
CL7
CL6
CL5
CL4
CL3
CL2
CL1
CL0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-32. Cycle Length Register
This register defines the number of macroticks per cycle. Writing this register is possible during the
configuration state only. The CC uses this register value during startup only.
MFR4200 Data Sheet, Rev. 0
80
Freescale Semiconductor
Memory Map and Registers
3.2.3.3.20
Maximum Cycle Length Deviation Register (MCLDAR)
FlexRay protocol related parameter – gdMaxDrift
Address 0xB8
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
MCLDA9
MCLDA8
r
r
r
r
r
r
rw*
rw*
7
6
5
4
3
2
1
0
MCLDA7
MCLDA6
MCLDA5
MCLDA4
MCLDA3
MCLDA2
MCLDA1
MCLDA0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-33. Maximum Cycle Length Deviation Register
This register defines the number of microticks for a communication cycle of another CC with the
maximum deviation of 1500 ppm with respect to the local oscillator.
Writing this register is possible only during the configuration state. The value for the MCLDAR is
calculated from Equation 3-5:
MCLDAR = ceil ( cycle_length[µT] * 1.5*10-3 )
3.2.3.3.21
Eqn. 3-5
External Offset Correction Register (EOCR)
FlexRay Protocol Related Parameter – pExternOffsetCorrection
Address 0xF4
Reset undefined state
15
14
13
12
11
10
9
8
EOC15
EOC14
EOC13
EOC12
EOC11
EOC10
EOC9
EOC8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
EOC7
EOC6
EOC5
EOC4
EOC3
EOC2
EOC1
EOC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-34. External Offset Correction Register
This register holds the absolute value of the initial external offset correction to be applied, together with
the internal clock synchronization value (see Section 3.2.3.3.23, “External Correction Control Register
(ECCR)”). The host may write this register during the configuration state only. The register value is
expressed in microticks.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
81
MFR4200 FlexRay Communication Controller
3.2.3.3.22
External Rate Correction Register (ERCR)
FlexRay Protocol Related Parameter – pExternRateCorrection
Address 0xF6
Reset undefined state
15
14
13
12
11
10
9
8
ECR15
ECR14
ECR13
ECR12
ECR11
ECR10
ECR9
ECR8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
ERC7
ERC6
ERC5
ERC4
ERC3
ERC2
ERC1
ERC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-35. External Rate Correction Register
This register holds the absolute value of the initial external rate correction to be applied, together with the
internal clock synchronization value (see Section 3.2.3.3.23, “External Correction Control Register
(ECCR)”). The host may write this register in the configuration state only. The register value is expressed
in microticks.
3.2.3.3.23
External Correction Control Register (ECCR)
Address 0xF8
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
ERCA
ERCE
EOCA
EOCE
r
r
r
r
rw
rwh
rw
rwh
Figure 3-36. External Correction Control Register
NOTE
This register must be set before the NIT start of communication cycle x, in
order to affect the clock correction in the communication cycle x+1.
EOCE — External Offset Correction Enable
0 – External offset correction disabled.
1 – External offset correction enabled.
MFR4200 Data Sheet, Rev. 0
82
Freescale Semiconductor
Memory Map and Registers
NOTE
If this bit is set by the host, external offset correction will be performed once
during the subsequent double cycle; afterwards, this bit will be cleared
automatically by the communication controller.
EOCA — External Offset Correction Application
0 – Add external offset correction value.
1 – Subtract external offset correction value.
ERCE — External Rate Correction Enable
0 – External rate correction disabled.
1 – External rate correction enabled.
NOTE
If this bit is set by the host, the external rate correction will be performed
once during the subsequent double cycle, and afterwards this bit will be
automatically cleared by the communication controller.
ERCA — External Rate Correction Application
0 – Add external rate correction.
1 – Subtract external rate correction.
3.2.3.3.24
Maximum Offset Correction Register (MOCR)
FlexRay Protocol Related Parameter – pOffsetCorrectionOut
Address 0xDA
Reset undefined state
15
14
13
12
11
10
9
8
MOC15
MOC14
MOC13
MOC12
MOC11
MOC10
MOC9
MOC8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
MOC7
MOC6
MOC5
MOC4
MOC3
MOC2
MOC1
MOC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-37. Maximum Offset Correction Register
This register defines the maximum permitted absolute offset correction value, in microticks, to be applied
by the internal clock synchronization algorithms. This register can be written during the configuration state
only. The value of this register does not effect the external clock correction value.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
83
MFR4200 FlexRay Communication Controller
3.2.3.3.25
Maximum Rate Correction Register (MRCR)
FlexRay Protocol Related Parameter – pRateCorrectionOut
Address 0xDC
Reset undefined state
15
14
13
12
11
10
9
8
MRC15
MRC14
MRC13
MRC12
MRC11
MRC10
MRC9
MRC8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
MRC7
MRC6
MRC5
MRC4
MRC3
MRC2
MRC1
MRC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-38. Maximum Rate Correction Register
This register defines the maximum permitted absolute rate correction value, in microticks, to be applied
by the internal clock synchronization algorithms. This register can be written during the configuration state
only. The value of this register does not effect the external clock correction value.
3.2.3.3.26
Coldstart Maximum Register (CSMR)
FlexRay Protocol Related Parameter – gColdStartAttempts
Address 0xC0
Reset undefined state
15
14
13
12
11
10
9
8
CMS15
CMS14
CMS13
CMS12
CMS11
CMS10
CMS9
CMS8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
CSM7
CSM6
CSM5
CSM4
CSM3
CSM2
CSM1
CSM0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-39. Coldstart Maximum Register
The value in this register determines the maximum number of coldstart attempts that a coldstarting startup
node is allowed to make, when trying to start up the network without receiving a valid response from
another node. After this number of coldstart attempts, the CC falls back to the integration listen state and
does not perform another coldstart attempt, until the controller enters and leaves the configuration state
again. If the register is programmed with the value ‘0’, then the CC is not allowed to start communication.
Writing the coldstart maximum register is possible during the configuration state only. The value of this
register must be within the range [0:32767].
MFR4200 Data Sheet, Rev. 0
84
Freescale Semiconductor
Memory Map and Registers
3.2.3.3.27
Transmit Start Sequence Length Register (TSSLR)
FlexRay Protocol Related Parameter – gdTSSTransmitter/pdTSSReceiver
Address 0xBA
Reset undefined state
15
14
13
12
11
10
9
8
TSSLR7
TSSLR6
TSSLR5
TSSLR4
TSSLR3
TSSLR2
TSSLR1
TSSLR0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
TSSLT7
TSSLT6
TSSLT5
TSSLT4
TSSLT3
TSSLT2
TSSLT1
TSSLT0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-40. Transmit Start Sequence Length Register
The TSSLR defines the length, in bits, of the transmit start sequence on the physical layer.
Bits TSSLT[0:7] (LSB) define the nominal length of the transmit start sequence for transmission.
Bits TSSLR[8:15] (MSB) define maximum length of the transmit start sequence for reception.
Writing is possible only during the configuration state.
3.2.3.3.28
Network Management Vector Length Register (NMVLR)
FlexRay Protocol Related Parameter – gNetworkManagementVectorLength
Address 0x3E
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
NMVL3
NMVL2
NMVL1
NMVL0
r
r
r
r
rw*
rw*
rw*
rw*
Figure 3-41. Network Management Vector Length Register
This register defines the length, in bytes, of the network management vector (see Section 3.2.3.4.6,
“Global Network Management Vector n Register, n = [0:5] (GNMVnR)”). Writing is possible during the
configuration state only. The value of this register must be within the range [0:12].
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
85
MFR4200 FlexRay Communication Controller
3.2.3.3.29
Sync Frame Register (SYNCFR)
Address 0x94
Reset 0x0
15
14
13
12
11
10
9
8
SUP
Reserved
Reserved
Reserved
Reserved
SYNCF10
SYNCF9
SYNCF8
rw*
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
SYNCF7
SYNCF6
SYNCF5
SYNCF4
SYNCF3
SYNCF2
SYNCF1
SYNCF0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-42. Sync Frame Register
This register contains the identifier of the sync frame to be transmitted. This register can be written during
the configuration state only. There is no sync frame to transmit, if this register holds the value 0x0. A hard
reset clears the register.
SUP — Startup
This bit sets the startup frame indicator. It can be written in the configuration state only.
1 – CC is a startup node and has its startup frame indicator set.
0 – CC is not a startup node.
3.2.3.3.30
Sync Frame Header Register (SYNCHR)
Address 0x96
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
SYNCRC10
SYNCRC9
SYNCRC8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
SYNCRC7
SYNCRC6
SYNCRC5
SYNCRC4
SYNCRC3
SYNCRC2
SYNCRC1
SYNCRC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-43. Sync Frame Header Register
This register contains the header CRC of the sync frame to be transmitted. This register can be written
during the configuration state only.
MFR4200 Data Sheet, Rev. 0
86
Freescale Semiconductor
Memory Map and Registers
NOTE
The SYNCHR value overwrites the header CRC field of a transmit message
buffer that: a) has the same frame ID as the SYNCF[0:10] field of the
SYNCFR (see Section 3.2.3.3.29, “Sync Frame Register (SYNCFR)”), and
b) was selected by the CC for transmission as a sync message.
3.2.3.3.31
Bus Guardian Tick Register (BGTR)
Address 0xAE
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
BGT4
BGT3
BGT2
BGT1
BGT0
r
r
r
rw*
rw*
rw*
rw*
rw*
Figure 3-44. Bus Guardian Tick Register
This register defines the period length of the bus guardian tick to be provided by the CC to the bus guardian.
The value BGT[0:4], is expressed in multiples of the CC microtick. Writing this register is possible only
during the configuration state. The value of this register must be within the range [2:16].
3.2.3.3.32
Delay Counter Register (DCR)
Address 0x3C
Reset 0x0
15
14
13
12
11
10
9
8
DC15
DC14
DC13
DC12
DC11
DC10
DC9
DC8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
DC7
DC6
DC5
DC4
DC3
DC2
DC1
DC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-45. Delay Counter Register
This register specifies the configurable part of the delay between the reset of the CONFIG bit (host writing
MCR0.CONFIG) and the point in time when the controller actually leaves the configuration state (see
Section 3.9.2, “Configuration State”). The delay is configurable in steps of eight microticks, i.e.
the configured value * 8 = delay in microticks
Eqn. 3-6
The host may write this register only during the configuration state.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
87
MFR4200 FlexRay Communication Controller
3.2.3.3.33
Debug Port Control Register (DBPCR)
Address 0x38
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
CNTRL7
CNTRL6
CNTRL5
CNTRL4
CNTRL3
CNTRL2
CNTRL1
CNTRL0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-46. Debug Port Control Register
This register controls the output functions of the BGT and ARM_BG pins of the controller as described in
Table 3-3.
Bits CNTRL[7:4] determine the functionality of the port BGT pin.
Bits CNTRL[3:0] determine the functionality of the port ARM_BG pin.
Refer to 3.10, “Debug Port” for a detailed description of the debug functions.
NOTE
The output function controls of BGT and ARM_BG pins are independent of
each other. Therefore, they may be set with equal or different values.
Table 3-3. Encoding of Debug Port Control Fields CNTRL[7:4] and CNTRL[3:0]
CNTRL[7:4],
CNTRL[3:0]
Mode of the BGT, Mode of the ARM_BG
Signal
0
Normal operation of BGT and ARM_BG
–
1
Protocol state change
PCS
2
Slot start in static segment
SSS
3
Minislot start
MSS
4
RxD after glitch filter on channel A
5
Dynamic slot start on channel A
6
Start of frame on channel A
7
Received syntactically correct an semantically valid frame indication on channel A
RCFA
8
Start of a communication cycle
SCC
9
Macrotick
MTS
10
Start of offset correction
SOC
11
–
12
RxD after glitch filter on channel B
RAGFA
DSSA
SFA
–
RAGFB
MFR4200 Data Sheet, Rev. 0
88
Freescale Semiconductor
Memory Map and Registers
Table 3-3. Encoding of Debug Port Control Fields CNTRL[7:4] and CNTRL[3:0] (continued)
CNTRL[7:4],
CNTRL[3:0]
Mode of the BGT, Mode of the ARM_BG
Signal
13
Dynamic slot start on channel B
14
Start of frame on channel B
15
Received syntactically correct an semantically valid frame indication on channel B
3.2.3.3.34
DSSB
SFB
RCFB
Start of Offset Correction Cycle Time Register (SOCCTR)
FlexRay Protocol Related Parameter – gOffsetCorrectionStart
Address 0xE0
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
SOCCT13
SOCCT12
SOCCT11
SOCCT10
SOCCT9
SOCCT8
r
r
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
SOCCT7
SOCCT6
SOCCT5
SOCCT4
SOCCT3
SOCCT2
SOCCT1
SOCCT0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-47. Start of Offset Correction Cycle Time Register
This register defines the delay time (in multiples of macroticks) after which the offset correction will start.
Writing this register is possible only during the configuration state.
NOTE
The time interval between the start time of the NIT (see NITCR) and the
Start of Offset Correction time is used by the CC for clock correction
calculations. The minimum interval that must be ensured during NITCR and
SOCCTR programming can be calculated from Equation 3-7:
Delaymin = ceil(500µT + 110µT*MSFR)/NMLR) + 1 [nominal MT]
Eqn. 3-7
Therefore, the SOCCTR value must be:
SOCCTR >= NITCR + Delaymin [nominal MT]
Eqn. 3-8
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
89
MFR4200 FlexRay Communication Controller
3.2.3.3.35
Idle Detection Length Register (IDLR)
FlexRay protocol related parameter – gdDynamicSlotIdlePhase
Address 0xAA
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
IDL3
IDL2
IDL1
IDL0
r
r
r
r
rw*
rw*
rw*
rw*
Figure 3-48. Idle Detection Length Register
This register defines the number of minislots used by the CC for checking the duration of the network idle
time between two consecutive frames in the dynamic segment. This includes the dynamic slot idle phase.
Writing this register is possible only during the configuration state.
The value of IDLR depends on the values of the bit duration register (Section 3.2.3.3.1, “Bit Duration
Register (BDR)) and the minislot length register (Section 3.2.3.3.12, “Minislot Length Register (MSLR)).
It can be calculated using Equation 3-9.
IDLR = ceil( (11 * BDR) / (NMLR * MSLR) ).
Eqn. 3-9
The value in the register must be in the range [1:15].
3.2.3.3.36
Symbol Window Control Register (SWCTRLR)
Address 0x84
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
CHB
CHA
Reserved
Reserved
Reserved
Reserved
Reserved
r
rw
rw
r
r
r
r
r
Figure 3-49. Symbol Window Control Register
This register controls the transmission of symbols in a symbol window of a communication cycle. The
register may be modified during the configuration state and during normal operation.
CHB and CHA determine whether a symbol will be transmitted on channel B or channel A, respectively.
1 – Symbol transmission enabled.
MFR4200 Data Sheet, Rev. 0
90
Freescale Semiconductor
Memory Map and Registers
0 – Symbol transmission disabled.
3.2.3.3.37
Wakeup Mechanism Control Register (WMCTRLR)
Address 0x8A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
CHB
CHA
CNT4
CNT3
CNT2
CNT1
CNT0
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-50. Wakeup Mechanism Control Register
This register controls the transmission of wakeup symbols. The register may be modified in the
configuration state only.
CHB and CHA determine whether a wakeup symbol will be transmitted on channel B or channel A,
respectively.
1 – Wakeup symbol transmission enabled.
0 – Wakeup symbol transmission disabled.
CNT[4:0] determine the number of wakeup symbols to be transmitted. The controller will transmit at least
two wakeup symbols if wakeup symbol transmission is enabled.
3.2.3.3.38
Wakeup Symbol TX Idle Register (WUSTXIR)
FlexRay protocol related parameter – gdWakeupSymbolTxIdle
Address 0xEA
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
CNT7
CNT6
CNT5
CNT4
CNT3
CNT2
CNT1
CNT0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-51. Wakeup Symbol TX Idle Register
This register controls the duration of the idle period of wakeup symbols. Bits CNT[7:0] determine the
duration of the idle period in bit durations on the network. The register may be modified in the
configuration state only.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
91
MFR4200 FlexRay Communication Controller
3.2.3.3.39
Wakeup Symbol TX Low Register (WUSTXLR)
FlexRay protocol related parameter – gdWakeupSymbolTxLow
Address 0xEC
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
CNT5
CNT4
CNT3
CNT2
CNT1
CNT0
r
r
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-52. Wakeup Symbol TX Low Register
This register controls the duration of the low period of wakeup symbols. Bits CNT[5:0] determine the
duration of the low period in bit durations on the network. The register may be modified only during the
configuration state.
3.2.3.3.40
Listen Timeout With Noise Length Register (LNLR)
FlexRay protocol related parameter – gListenNoise
Address 0xD6
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
CNT4
CNT3
CNT2
CNT1
CNT0
r
r
r
rw*
rw*
rw*
rw*
rw*
Figure 3-53. Listen Timeout With Noise Length Register
This register controls the duration of the listen timeout with noise. Bits CNT[4:0] determine the duration
of the listen timeout as a number of communication cycles. The register may be modified in the
configuration state only.
MFR4200 Data Sheet, Rev. 0
92
Freescale Semiconductor
Memory Map and Registers
3.2.3.4
3.2.3.4.1
Status Registers
Protocol State Register (PSR)
Address 0x0C
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
PS4
PS3
PS2
PS1
PS0
r
r
r
rh
rh
rh
rh
rh
Figure 3-54. Protocol State Register
This register is used to indicate the internal state of the CC. This register is read-only for the host. A hard
reset clears the register.
Table 3-4. CC State Coding
Code (Decimal)
Slot Status Monitoring
available
Configuration
0
No
Initialize Schedule
1
No
Normal Active Operation
2
Yes
Normal Passive Operation
3
Yes
Integration Consistency Check
4
Yes
Integration Listen
5
No
Coldstart Listen
21
No
Integration Coldstart Check
22
Yes
Join Coldstart
23
Yes
Coldstart Collision Resolution
24
No
Coldstart Consistency Check
25
Yes
Coldstart Gap
26
No
Wakeup
11
No
CC State
NOTE
Refer to note 2 in Section 3.2.3.5.7, “Slot Status Counter n Register,
n = [0:7] (SSCnR)” for information on the MFR4200 slot status monitoring
mechanisms.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
93
MFR4200 FlexRay Communication Controller
3.2.3.4.2
Current Cycle Counter Value Register (CCCVR)
FlexRay protocol related parameter – vCycle
Address 0x0A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
CCCV5
CCCV4
CCCV3
CCCV2
CCCV1
CCCV0
r
r
rh
rh
rh
rh
rh
rh
Figure 3-55. Current Cycle Counter Value Register
This register provides the current cycle counter value (bits CCCV[4:0]). The register is cleared by a hard
reset or when leaving the configuration state. If the maximum value is reached, the counter wraps around
to zero and continues counting.
The current cycle counter value is measured in communication cycles.
3.2.3.4.3
Current Macrotick Counter Value Register (CMCVR)
FlexRay protocol related parameter – vMacrotick
Address 0x08
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
CMCV13
CMCV12
CMCV11
CMCV10
CMCV9
CMCV8
r
r
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
CMCV7
CMCV6
CMCV5
CMCV4
CMCV3
CMCV2
CMCV1
CMCV0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-56. Current Macrotick Counter Value Register
This register indicates the current cycle time in macroticks (bits CMCV[13:0]. The register is cleared by a
hard reset or when leaving the configuration state. The CC increments the register during the cycle, and
clears it at the start of a new cycle.
MFR4200 Data Sheet, Rev. 0
94
Freescale Semiconductor
Memory Map and Registers
3.2.3.4.4
Offset Correction Value Register (OCVR)
FlexRay protocol related parameter – vOffsetCorrection
Address 0x32C
Reset undefined state
15
14
13
12
11
10
9
8
OCV15
OCV14
OCV13
OCV12
OCV11
OCV10
OCV9
OCV8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
OCV7
OCV6
OCV5
OCV4
OCV3
OCV2
OCV1
OCV0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-57. Offset Correction Value Register
This read-only register indicates the offset correction value, in microticks, calculated by the clock
synchronization algorithm (before external offset correction and before value limitation), at the end of each
communication cycle. Data in this register is presented in 2’s complement form. The value in this register
is valid after a communication cycle start and until its NIT start. The CC modifies OCVR during the NIT.
3.2.3.4.5
Rate Correction Value Register (RCVR)
FlexRay protocol related parameter – vRateCorrection
Address 0x32A
Reset undefined state
15
14
13
12
11
10
9
8
RCV15
RCV14
RCV13
RCV12
RCV11
RCV10
RCV9
RCV8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
RCV7
RCV6
RCV5
RCV4
RCV3
RCV2
RCV1
RCV0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-58. Rate Correction Value Register
This read-only register indicates the rate correction value, in microticks, calculated by the clock
synchronization algorithm (before external rate correction and value limitation), at the end of each odd
communication cycle. Data in this register is presented in 2’s complement form.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
95
MFR4200 FlexRay Communication Controller
3.2.3.4.6
Global Network Management Vector n Register, n = [0:5] (GNMVnR)
Address GNMV0R=0x40, GNMV1R=0x42, GNMV2R=0x44, GNMV3R=0x46, GNMV4R=0x48, GNMV5R=0x4A,
Reset 0x0
15
14
13
12
11
10
9
8
GNMV15
GNMV14
GNMV13
GNMV12
GNMV11
GNMV10
GNMV9
GNMV8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
GNMV7
GNMV6
GNMV5
GNMV4
GNMV3
GNMV2
GNMV1
GNMV0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-59. Global Network Management Vector n Register, n = [0:5]
These read-only registers hold the global network management vector. The length of the network
management vector is configured by means of the NMVLR register (see Section 3.2.3.3.28, “Network
Management Vector Length Register (NMVLR)”). The GNMVnR registers are cleared during a hard reset.
NOTE
If the NMVLR register is programmed with a value less than 12, then the
remaining bytes of the GNMVnR registers (which are not used for network
management vector accumulating) will remain 0’s.
The global network management vector, as presented in the communication cycle x, is the
OR-combination of all network management vectors received in the communication cycle x-1. The
controller ensures that the value read from GNMV0R is consistent.
The mapping between the receive message buffer payload bytes and the GNMVnR registers is shown in
Table 3-5. (See also Section , “Receive, receive FIFO, and transmit message buffers are accessible to the
host MCU only through the active receive, active transmit, and active receive FIFO buffers.”.)
Table 3-5. Mapping between Receive Message Buffer Payload Bytes and GNMVnR Registers
GNMVnR
Byte
NMVectorn
GNMV0R
MSB
NMVector1
LSB
NMVector0
MSB
NMVector3
LSB
NMVector2
GNMV1R
…
GNMV5R
MSB
NMVector11
LSB
NMVector10
MFR4200 Data Sheet, Rev. 0
96
Freescale Semiconductor
Memory Map and Registers
3.2.3.4.7
Symbol Window Status channel A Register (SWSAR)
Address 0x86
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
SYMB
CH
r
r
r
r
r
r
rh
rh
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-60. Symbol Window Status Channel A Register
This register holds the symbol window status for channel A. The symbol window status is the same as a
regular slot status as described in Section 3.3.3, “Message Buffer Slot Status Vector”, with the addition of
the SYMB flag.
SYMB — Symbol
This flag indicates the reception of a symbol in the symbol window.
0 – No symbol received.
1 – Symbol received.
TXCON — TX Conflict
This flag indicates transmission conflicts, i.e. indicates that a reception is ongoing when the controller
starts transmission. This bit indicates conflicts during transmission in a symbol window.
0 – No transmission conflict detected
1 – Transmission conflict detected
Refer to Section 3.3.3, “Message Buffer Slot Status Vector” for a description of the other bits in this
register.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
97
MFR4200 FlexRay Communication Controller
3.2.3.4.8
Symbol Window Status Channel B Register (SWSBR)
Address 0x88
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
SYMB
CH
r
r
r
r
r
r
rh
rh
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-61. Symbol Window Status Channel B Register
This register holds the symbol window status for channel B. The symbol window status is the same as a
regular slot status as described in Section 3.3.3, “Message Buffer Slot Status Vector”, with the addition of
the SYMB flag.
SYMB — Symbol
This flag indicates the reception of a symbol in the symbol window.
0 – No symbol received.
1 – Symbol received.
TXCON — TX Conflict
This flag indicates transmission conflicts, i.e. indicates that a reception is ongoing when the controller
starts transmission. This bit indicates conflicts during transmission in a symbol window.
0 – No transmission conflict detected
1 – Transmission conflict detected
Refer to Section 3.3.3, “Message Buffer Slot Status Vector” for a description of the other bits in this
register.
MFR4200 Data Sheet, Rev. 0
98
Freescale Semiconductor
Memory Map and Registers
3.2.3.4.9
Bus Guardian Status Register (BGSR)
Address 0x3A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
BGSME1
BGSME0
BGRR
r
r
r
r
r
rh
rh
rh
Figure 3-62. Bus Guardian Status Register
This register holds the bus guardian status.
BGRR — Bus Guardian Reset Request
Request to the host to reset the bus guardian.
1 – BG reset request.
0 – No BG reset request.
BGSME0 – Bus Guardian Schedule Monitoring Error Indication for channel A
Indication of a bus guardian schedule monitoring error on channel A.
1 – BGSM error on channel A.
0 – No BGSM error on channel A.
BGSME1 — Bus Guardian Schedule Monitoring Error Indication for channel B
Indication of a bus guardian schedule monitoring error on channel B.
1 – BGSM error on channel B.
0 – No BGSM error on channel B.
NOTE
If at least one of the BGSME bits is set, the BGS bit is set in the ISR0 (see
Section 3.2.3.6.6, “Interrupt Status Register 0 (ISR0)”), and an interrupt is
generated if enabled (see Section 3.2.3.5.5, “Interrupt Enable Register 0
(IER0)”).
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
99
MFR4200 FlexRay Communication Controller
3.2.3.5
3.2.3.5.1
Interrupt and Error Signaling Related Control Registers
Startup Interrupt Enable Register (SIER)
Address 0x16
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
CDSTPNSIE
CDSTPNIE
PLFIE
CDSTMIE
r
r
r
r
rw
rw
rw
rw
Figure 3-63. Startup Interrupt Enable Register
This register holds the interrupt enable flags related to the startup interrupt status register (see
Section 3.2.3.6.7, “Startup Interrupt Status Register (SISR)”). The SIER register is cleared during a hard
reset.
CDSTMIE — Coldstart Max Interrupt Enable
1 – Coldstart max interrupt enabled.
0 – Coldstart max interrupt disabled.
PLFIE — Plausibility Failed Interrupt Enable
1 – Plausibility failed interrupt enabled.
0 – Plausibility failed interrupt disabled.
CDSTPNIE — Coldstart Path Normal Interrupt Enable
1 – Coldstart path normal interrupt enabled.
0 – Coldstart path normal interrupt disabled.
CDSTPNSIE — Coldstart Path Noise Interrupt Enable
1 – Coldstart path noise interrupt enabled.
0 – Coldstart path noise interrupt disabled.
CDSTPNSIE — Coldstart Path Noise Interrupt Enable
1 – Coldstart path noise interrupt enabled.
0 – Coldstart path noise interrupt disabled
MFR4200 Data Sheet, Rev. 0
100
Freescale Semiconductor
Memory Map and Registers
3.2.3.5.2
Maximum Odd Cycles Without Clock Correction Fatal Register (MOCWCFR)
FlexRay protocol related parameter – gMaxWithoutClockCorrectionFatal
Address 0xCC
Reset undefined state
15
14
13
12
11
10
9
8
MCWCF15
MCWCF14
MCWCF14
MCWCF14
MCWCF14
MCWCF14
MCWCF14
MCWCF14
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
MCWCF14
MCWCF14
MCWCF14
MCWCF4
MCWCF3
MCWCF2
MCWCF1
MCWCF0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-64. Maximum Odd Cycles Without Clock Correction Fatal Register
This register holds the maximum number of odd communication cycles (double cycles) before a node
enters the diagnosis stop state due to missing sync frame pairs (missing rate correction).
The register can be written only in the configuration state. If the CCFCV register value equals the
MOCWCFR register value, the CC will enter the ‘red’ error state (see Section 3.2.3.6.5, “Error Handling
Level Register (EHLR)”), and will signal this to the host by raising an interrupt.
According to the protocol specification, the value of this register lies in the range [1:15]; however, the
current implementation supports values in the range [1:32767].
3.2.3.5.3
Maximum Odd Cycles Without clock Correction Passive Register (MOCWCPR)
FlexRay protocol related parameter – gMaxWithoutClockCorrectonPassive
Address 0xD8
Reset undefined state
15
14
13
12
11
10
9
8
MCWCP15
MCWCP14
MCWCP13
MCWCP12
MCWCP11
MCWCP10
MCWCP9
MCWCP8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
MCWCP7
MCWCP6
MCWCP5
MCWCP4
MCWCP3
MCWCP2
MCWCP1
MCWCP0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-65. Maximum Odd Cycles Without Clock Correction Passive Register
This register holds the maximum number of odd communication cycles (double cycles) before a node
enters the passive state due to missing sync frame pairs (missing rate correction).
The register can be written only in the configuration state. If the CCFCR register value (see
Section 3.2.3.6.4, “Clock Correction Failed Counter Register (CCFCR)”) equals the MOCWCPR register
value, the CC will enter the ‘yellow’ error state (see Section 3.2.3.6.5, “Error Handling Level Register
(EHLR)”), and will signal this to the host by raising an interrupt. According to the protocol specification,
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
101
MFR4200 FlexRay Communication Controller
the value of this register lies in the range [1:15]; however, the current implementation supports values in
the range [1:32767].
3.2.3.5.4
Channel Status Error Counter n Register, n = [0:1] (CSECnR)
Address 0x2C, 0x2E
Reset 0x0
15
14
13
12
11
10
9
8
CNT15
CNT14
CNT13
CNT12
CNT11
CNT10
CNT9
CNT8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
CNT7
CNT6
CNT5
CNT4
CNT3
CNT2
CNT1
CNT0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-66. Channel Status Error Counter n Register, n = [0:1]
Channel status error counters CSEC0R and CSEC1R wrap around after they reach the maximum value.
These registers are reset when leaving the configuration state.
CSEC0R is assigned to channel A of the CC.
CSEC1R is assigned to channel B of the CC.
The controller generates a slot status vector for:
• every static slot
• dynamic slots during which the controller receives or transmits a frame
• symbol window
• network idle time on either channel
The controller increments the corresponding channel status error counter once if any slot status error bit
(bits 0–3 of the slot status vector) is set.
Channel status error counters are independent of other slot status monitoring mechanisms, i.e. message
buffers (Section 3.2.3.7, “Message Buffers and FIFO Configuration Related Registers”), slot status
registers (Section 3.2.3.6.8, “Slot Status n Register with n = [0:7] (SSnR)”), and slot status counters
(Section 3.2.3.5.7, “Slot Status Counter n Register, n = [0:7] (SSCnR)”).
•
•
NOTE
To determine the number of errors that occurred during a certain period
of time, the host must store intermediate values of the channel status
error counters.
If a frame exceeds a slot boundary, the controller increments the channel
status error counter twice, because a slot boundary violation always
affects two slots.
MFR4200 Data Sheet, Rev. 0
102
Freescale Semiconductor
Memory Map and Registers
•
3.2.3.5.5
Refer to Table 3-4 for slot status monitoring availability in different
protocol states.
Interrupt Enable Register 0 (IER0)
Address 0x14
Reset 0x0
15
14
13
12
11
10
9
8
FATALIE
CCLRIE
MAXSYNCIE
EHLCIE
MRCEIE
SSINTIE
BGSIE
MOCEIE
rw
rw
rw
rw
rw
rw
rw
rw
7
6
5
4
3
2
1
0
TIF1IE
TIF0IE
CYCIE
RFOIE
RFNEIE
CHIERRIE
TXIE
RXIE
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-67. Interrupt Enable Register 0
Each bit in the IER0 register enables its corresponding interrupt in the ISR0 register (see Section 3.2.3.6.6,
“Interrupt Status Register 0 (ISR0)”). Their meaning is as follows:
0 – The corresponding interrupt is disabled.
1 – The corresponding interrupt enabled.
3.2.3.5.6
Slot Status Selection n Register, n = [0:3] (SSSnR)
Address SSS0R=0x6C, SSS1R=0x6E, SSS2R=0x70, SSS3R=0x72
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
ID10
ID9
ID8
r
r
r
r
r
rw
rw
rw
7
6
5
4
3
2
1
0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-68. Slot Status Selection n Register, n = [0:3]
This set of n registers selects the static slot IDs for which the status will be provided in the SSnR registers
(see Section 3.2.3.6.8, “Slot Status n Register with n = [0:7] (SSnR)”).
NOTE
SSSnR cannot be used for dynamic slots or minislots.
ID[0:10] — Slot Status Slot ID Selection
ID[0:10] select the ID of the slot to observe.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
103
MFR4200 FlexRay Communication Controller
3.2.3.5.7
Slot Status Counter n Register, n = [0:7] (SSCnR)
Address SSC0R=0x4C, SSC1R=0x4E, SSC2R=0x50, SSC3R=0x52, SSC4R=0x54, SSC5R=0x56, SSC6R=0x58,
SSC7R=0x5A
Reset 0x0
15
14
13
12
11
10
9
8
CNT15
CNT14
CNT13
CNT12
CNT11
CNT10
CNT9
CNT8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
CNT7
CNT6
CNT5
CNT4
CNT3
CNT2
CNT1
CNT0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-69. Slot Status Counter n Register, n = [0:7]
Slot status counters may trigger interrupts via the SSCIR register (see Section 3.2.3.5.9, “Slot Status
Counter Incrementation Register (SSCIR)”). These interrupts may be enabled via the SSCIMR register
(see Section 3.2.3.5.10, “Slot Status Counter Interrupt Mask Register (SSCIMR)”). Refer to Table 3-4 for
slot status monitoring availability in different protocol states.
The controller increments the internal slot status counter whenever the slot status provided by the protocol
engine fulfills the status condition specified in the corresponding slot status counter condition register
SSCCnR. The internal slot status counter is not directly visible to the host. Depending on the value of bit
MULTCYC of the corresponding register SSCCnR (see Section 3.2.3.5.8, “Slot Status Counter Condition
n Register, n = [0:7] (SSCCnR)”), the controller either clears the internal slot status counter with every
cycle start (MULTCYC = 0) or keeps on incrementing continuously (MULTCYC = 1).
The host always gets the value of the internal slot status counter for the previous comunication cycle
(MULTCYC = 0) or cycles (MULTCYC = 1), when accessing slot status counters SSCnR.
Slot status counters do not wraparound.
•
•
•
NOTE 1
To clear slot status counter SSCnR, the host must reset bit MULTCYC
in the corresponding slot status counter condition register SSCCnR. The
controller will then reset the internal slot status counter at the beginning
of the following cycle, and the host will get the accumulated value of the
internal slot status counter at the end of the following cycle.
The controller clears all internal slot status counters when leaving the
configuration state.
The controller clears an internal slot status counter at the beginning of
every cycle, if bit MULTCYC is 0 in the corresponding slot status
counter condition register.
NOTE 2
The controller provides four independent slot status monitoring
mechanisms:
MFR4200 Data Sheet, Rev. 0
104
Freescale Semiconductor
Memory Map and Registers
•
•
•
•
•
3.2.3.5.8
Slot status registers SSnR configured via slot status selection registers
SSSnR, as described in Section 3.2.3.6.8, “Slot Status n Register with
n = [0:7] (SSnR)” and Section 3.2.3.5.6, “Slot Status Selection n
Register, n = [0:3] (SSSnR)”.
Channel status error counters CSEC0R and CSEC1R, as described in
Section 3.2.3.5.4, “Channel Status Error Counter n Register, n = [0:1]
(CSECnR)”.
Slot status information within message buffers, as described in
Section 3.3.3, “Message Buffer Slot Status Vector”.
Slot status counter registers SSCnR configured via slot status counter
condition registers SSCCnR as described in Section 3.2.3.5.7, “Slot
Status Counter n Register, n = [0:7] (SSCnR)” and Section 3.2.3.5.8,
“Slot Status Counter Condition n Register, n = [0:7] (SSCCnR)”.
Refer to Table 3-4 for slot status monitoring availability in different
protocol states.
Slot Status Counter Condition n Register, n = [0:7] (SSCCnR)
Address SSCC0R=0x5C, SSCC1R=0x5E, SSCC2R=0x60, SSCC3R=0x62, SSCC4R=0x64, SSCC5R=0x66, SSCC6R=0x68,
SSCC7R=0x6A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
CHCFG1
CHCFG0
MULTCYC
r
r
r
r
r
rw
rw
rw
7
6
5
4
3
2
1
0
VCES
SYNCFS
NULLFS
SUPFS
SSCM3
SSCM2
SSCM1
SSCM0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-70. Slot Status Counter Condition n Register, n = [0:7]
Each of these registers serves as condition to detect if the corresponding slot status counter (see
Section 3.2.3.5.7, “Slot Status Counter n Register, n = [0:7] (SSCnR)”) is to be incremented.
SSCMx, x = [0:3] — Slot Status Mask
A binary AND operation is performed on this 4-bit vector and the status of each slot-channel tuple that is
not booked for transmission in the static part of the communication cycle.
If the result is 0, and conditions for null frame selection (NULLS), sync frame selection (SYNCS), startup
frame selection (SUPFS), and valid communication element selection (VCES) are not met, the counter will
not be incremented for that slot-channel tuple.
NULLFS — NULL Frame Selection
This register is used to restrict counting to received null frames only.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
105
MFR4200 FlexRay Communication Controller
0 – The slot status counter is incremented independently of the null frame indication bit.
1 – The slot status counter is incremented only when a syntactically correct null frame is received.
SYNCFS — SYNC Frame Selection
This register can be used to restrict counting to received sync frames only.
0 – The slot status counter can be incremented independently of the sync frame bit.
1 – The slot status counter can be incremented only when a syntactically correct sync frame is received.
SUPFS — StartUP Frame Selection
This register can be used to restrict counting to received startup frames only.
0 – The slot status counter can be incremented independently of the startup bit.
1 – The slot status counter can be incremented only when a syntactically correct startup frame is received.
VCES — Valid Communication Element Selection
This register can be used to restrict counting to semantically valid frames only.
0 – The slot status counter can be incremented for semantically valid and invalid frames.
1 – The slot status counter can be incremented only when a semantically valid frame is received.
MULTCYC — Multiple Cycle
This bit determines if the slot status counter reflects the values of multiple communication cycles or of the
previous communication cycle only. Note that MULTCYC may be written during normal operation, but its
value must not be modified by the host during the NIT.
0 – The internal slot status counter starts at 0 at the beginning of every communication cycle, and SSCnR
reflects the values of the previous communication cycle.
1 – The internal slot status counter is not reset to 0 at the beginning of every communication cycle; this
allows counting of specific slot status conditions over several communication cycles. SSCnR reflects the
accumulated values counted in previous communication cycles.
CHCFG1, CHCFG0 — Channel Configuration
These bits determine the channel assignment for slot status counters SSCnR, as defined in Table 3-6.
Table 3-6. Channel Configuration for SSCCnR
CHCFG1
CHCFG0
Meaning
0
0
Count for channel A
0
1
Count for channel B
MFR4200 Data Sheet, Rev. 0
106
Freescale Semiconductor
Memory Map and Registers
Table 3-6. Channel Configuration for SSCCnR
CHCFG1
CHCFG0
Meaning
1
0
Count for both channels only once even if the counting
condition is fulfilled for both channels
1
1
Count for both channels independently. If the counting
condition is fulfilled for both channels, count twice.
NOTE
Slot status counting is supported for the static segment only.
3.2.3.5.9
Slot Status Counter Incrementation Register (SSCIR)
Address 0x28
Reset 0x0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
SSCIR7
SSCIR6
SSCIR5
SSCIR4
SSCIR3
SSCIR2
SSCIR1
SSCIR0
rwh
rwh
rwh
rwh
rwh
rwh
rwh
rwh
Figure 3-71. Slot Status Counter Incrementation Register
This register contains one bit, SSCIRn, for each slot status counter SSCnR (see Section 3.2.3.5.7, “Slot
Status Counter n Register, n = [0:7] (SSCnR)”). Bit SSCIRn is set when the slot status counter SSCnR is
incremented. The register is reset on leaving the configuration state. The host may clear individually each
bit in register SSCIR by writing a ‘1’ to it.
3.2.3.5.10
Slot Status Counter Interrupt Mask Register (SSCIMR)
Address 0x2A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
SSCIMR7
SSCIMR6
SSCIMR5
SSCIMR4
SSCIMR3
SSCIMR2
SSCIMR1
SSCIMR0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-72. Slot Status Counter Interrupt Mask Register
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
107
MFR4200 FlexRay Communication Controller
Via this register, the host may enable individually each bit in the SSCIR (see Section 3.2.3.5.9, “Slot Status
Counter Incrementation Register (SSCIR)”) to trigger the interrupt SSINT in the ISR0 (see
Section 3.2.3.6.6, “Interrupt Status Register 0 (ISR0)”.
1 – If the corresponding bit in register SSCIR is set, trigger the interrupt SSINT.
0 – Ignore the corresponding bit in register SSCIR; do not trigger an interrupt.
3.2.3.6
3.2.3.6.1
Interrupt and Error Signaling Related Status Registers
Receive Buffer Interrupt Vector Register (RBIVECR)
Address 0x24
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
RBIVEC5
RBIVEC4
RBIVEC3
RBIVEC2
RBIVEC1
RBIVEC0
r
r
rh
rh
rh
rh
rh
rh
Figure 3-73. Receive Buffer Interrupt Vector Register
This register indicates the lowest numbered receive message buffer that has its interrupt status flag (IFLG)
and its interrupt enable (IENA) bits set. The register is cleared by a hard reset or by leaving the
configuration state.
•
•
•
NOTE
After an IFLG has been set or cleared, the CC updates the RBIVECR
register after 1 µT.
The RBIVECR register contains valid data only if the RXIF bit is set
(see Section 3.2.3.6.6, “Interrupt Status Register 0 (ISR0)”).
If there are no IFLG bits set for any receive message buffers that have
their IENA bit set, then the CC sets the RBIVECR register to 0x0000
(IFLG, IENA — see Section 3.2.3.7.2, “Message Buffer Control,
Configuration and Status n Register, n = [0:58] (BUFCSnR)”).
MFR4200 Data Sheet, Rev. 0
108
Freescale Semiconductor
Memory Map and Registers
3.2.3.6.2
Transmit Buffer Interrupt Vector Register (TBIVECR)
Address 0x26
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
TBIVEC5
TBIVEC4
TBIVEC3
TBIVEC2
TBIVEC1
TBIVEC0
r
r
rh
rh
rh
rh
rh
rh
Figure 3-74. Transmit Buffer Interrupt Vector Register
This register indicates the lowest numbered transmit message buffer that has its interrupt status flag (IFLG)
and its interrupt enable (IENA) bits set. A hard reset or leaving the configuration state clear the register.
•
•
•
3.2.3.6.3
NOTE
After an IFLG has been set or cleared, the CC updates the TBIVECR
register after 1 µT.
The TBIVECR register contains valid data only if the TXIF bit is set (see
Section 3.2.3.6.6, “Interrupt Status Register 0 (ISR0)”).
If there are no IFLG bits set for any transmit message buffers that have
their IENA bit set, then the CC sets the TBIVECR register to 0x0000
(IFLG, IENA — see Section 3.2.3.7.2, “Message Buffer Control,
Configuration and Status n Register, n = [0:58] (BUFCSnR)”).
CHI Error Register (CHIER)
Address 0x12
Reset 0x0
15
14
13
12
11
10
9
8
ILLADR
NMENF
NMEFTS
SPLME
MDPLE
BULE
EFLE
FBLE
rwh
rwh
rwh
rwh
rwh
rwh
rwh
rwh
7
6
5
4
3
2
1
0
TBLE
RBLE
Reserved
CCPBLE
BB
Reserved
IRE
FLE
rwh
rwh
r
rwh
rwh
r
rwh
rwh
Figure 3-75. CHI Error Register
This register holds CHI status flags. The host clears any status bit in the CHIER by writing a '1' to it;
writing a ‘0’ does not change the bit state. The CC sets a status bit in the CHIER again, when it detects the
condition for that bit. If the host and the CC try to write the CHIER register at the same time, the CC write
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
109
MFR4200 FlexRay Communication Controller
operation has the higher priority. If the host tries to clear a set error flag in the CHIER register, while the
CC at the same time sets this bit, the error flag will remain set. A hard reset clears the register.
NOTE
When any error is processed by the CC, and indicated in the CHIER register,
the CC raises an interrupt, if configured to do so by means of the ISR0 and
IER0 bits, and continues operation without changing state.
FLE — Frame Lost Error
This error occurs if the host has locked a receive message buffer, and two semantically valid frames for
that buffer are received during this locked time. The first frame will be lost.
1 – Frame lost error detected.
0 – No frame lost error detected.
IRE — Illegal Reconfiguration Error
This error appears if the host tries to reconfigure a dynamic transmit message buffer to a static one. The
reconfiguration, in that case, is ignored by the CC.
1 – Illegal reconfiguration error detected.
0 – No illegal reconfiguration error detected.
BB — Buffer Busy
This bit is set if the host tries to lock a message buffer that is locked by the CC for internal operations. The
CC, in that case, does not grant access to the message buffer through the locking mechanism.
1 – Buffer busy detected.
0 – No buffer busy detected.
Buffer Locking Errors:
CCPBLE — CC Part Buffer of a Double Transmit Message Buffer Lock Error
This error is raised if the host tries to lock a CC part buffer of a double transmit message buffer. The CC,
in that case, does not grant access to the CC part buffer of a double transmit message buffer through the
locking mechanism.
1 – CCPBLE detected.
0 – No CCPBLE detected.
RBLE — Receive Message Buffers Locking Error
This error appears if the host tries to lock more than 1 receive message buffer. The CC in that case does
not grant access to the buffer through the locking mechanism.
1 – RBLE detected.
MFR4200 Data Sheet, Rev. 0
110
Freescale Semiconductor
Memory Map and Registers
0 – No RBLE detected.
TBLE — Transmit Message Buffers Locking Error
This error appears if the host tries to lock more than one transmit message buffer. The CC, in that case,
does not grant access to the buffer through the locking mechanism.
1 – TBLE detected.
0 – No TBLE detected.
FBLE — FIFO Message Buffer Lock Error
This error appears if the host tries to lock a FIFO message buffer not through message buffer 0. The CC,
in that case, does not grant access to the message buffer through the locking mechanism.
1 – FBLE detected.
0 – No FBLE detected.
EFLE — Empty FIFO Lock Error
This error appears if the host tries to lock an empty FIFO. The CC, in that case, does not grant access to
the FIFO through the locking mechanism.
1 – EFLE detected.
0 – No EFLE detected.
BULE — Unlocked Message Buffer Lock Error
This error appears if the host tries to access an unlocked message buffer through any active message buffer.
In that case, the host write operations to an active message buffer are ignored, and read operations return
0’s.
1 – BULE detected.
0 – No BULE detected.
Other Error Indicators:
MDPLE — Maximum Dynamic Payload Length Exceeded Error
This error appears if the payload length written into a dynamic segment transmit message buffer
PayloadLength field is greater than the maximum payload length dynamic configured in the maximum
payload length dynamic register MPLDR (see Section 3.2.3.3.16, “Maximum Payload Length Dynamic
Register (MPLDR)”). In that case, the wrong payload length is ignored.
1 – MDPLE detected.
0 – No MDPLE detected.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
111
MFR4200 FlexRay Communication Controller
SPLME — Static Payload Length Mismatch Error
This error appears if the payload length written into a static segment transmit message buffer is not equal
to the static payload length configured within the static payload length register SPLR (see
Section 3.2.3.3.11, “Static Payload Length Register (SPLR)”). In that case, the wrong payload length is
ignored.
1 – SPLME detected.
0 – No SPLME detected.
NMEFTS — Network Management Error Frame Too Short
This error appears if the payload length value of a received message is not big enough to hold the complete
configured NM vector. However, the received part of the NM vector is used for the NM vector update (see
Section 3.2.3.4.6, “Global Network Management Vector n Register, n = [0:5] (GNMVnR)”).
1 – NMEFTS detected.
0 – No NMEFTS detected.
NMENF — Network Management Error Null Frame
This error appears if a received message with an NM bit set has a null frame bit set. In that case, the
GNMVnR registers are not updated.
1 – NMENF detected.
0 – No NMENF detected.
ILLADR — Illegal Address
This error appears if the host tries to perform a byte access (a write access, if the HCS12 interface is
selected) or an unaligned word access.
If the HCS12 interface is selected (see chapter Section 3.7, “Host Controller Interfaces”), and this error
appears, the CC presents the data value 0x0000 to the host and indicates an IILADR error.
NOTE
The address space from 0x0400 to 0x1FFF in the MFR4200 memory map
is reserved. Reading this address space results in data 0x0000, while writing
does not change the memory. Reading or writing this address space will set
the ILLADR bit.
1 – ILLADR detected.
0 – No ILLADR detected.
MFR4200 Data Sheet, Rev. 0
112
Freescale Semiconductor
Memory Map and Registers
3.2.3.6.4
Clock Correction Failed Counter Register (CCFCR)
FlexRay Protocol Related Parameter – vClockCorrectionFailed
Address 0x326
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
OWCC3
OWCC2
OWCC1
OWCC0
r
r
r
r
rh
rh
rh
rh
Figure 3-76. Clock Correction Failed Counter Register
This register holds the clock correction failed counter. This counter is reset when a node enters normal
active operation. It is incremented by one at the end of any odd communication cycle, when either the
missing offset correction error or the missing rate correction error, or both, are active. The counter is reset
to zero at the end of an odd communication cycle if neither the offset correction failed error nor the rate
correction failed error is active. The counter is not incremented after it reaches the maximum odd
communication cycles without clock correction programmed value (see Section 3.2.3.5.2, “Maximum
Odd Cycles Without Clock Correction Fatal Register (MOCWCFR)”). The host has read-only access to
this register.
3.2.3.6.5
Error Handling Level Register (EHLR)
Address 0x328
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
EHL1
EHL0
r
r
r
r
r
r
rh
rh
Figure 3-77. Error Handling Level Register
This register holds the current value of the error handling level. Error handling levels are defined in
Table 3-7:
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
113
MFR4200 FlexRay Communication Controller
Table 3-7. Error Handling Level Coding
3.2.3.6.6
EHL1
EHL0
Error Handling Level
CC state
0
0
Green level
Normal Active
0
1
Yellow level
Normal Passive
1
0
Red level
Diagnosis Stop
1
1
Not used
–
Interrupt Status Register 0 (ISR0)
Address 0x0E
Reset 0x0
15
14
13
12
11
10
9
8
FATAL
CCLR
MAXSYNC
EHLC
MRCE
SSINT
BGS
MOCE
rwh
rwh
rwh
rwh
rwh
rwh
rwh
rwh
7
6
5
4
3
2
1
0
TIF1
TIF0
CYCIF
RFOIF
RFNEIF
CHIERRIF
TXIF
RXIF
rwh
rwh
rwh
rwh
rwh
rwh
rwh
rwh
Figure 3-78. Interrupt Status Register 0
This register indicates the occurrence of interrupt events. Together with IER0 (see Section 3.2.3.5.5,
“Interrupt Enable Register 0 (IER0)”), it allows the module to operate in a polled or interrupt driven
system.
•
•
•
•
NOTE
The host clears any status bit in the ISR0 by writing a '1' to the bit.
Writing a ‘0’ does not change the bit state.
The CC sets a status bit of the ISR0 again when it detects the condition
for that bit.
The host must resolve the conditions causing the RFNEIF, CHIERRIF,
TXIF, and RXIF bits to be asserted, as these flags are updated
automatically by the CC, depending on conditions related to these flags.
If the host does not resolve the conditions that lead to these flags being
asserted, the CC ignores the host’s clear operation for these bits and the
bits remain asserted.
If the host and the CC try to write the ISR0 register at the same time, the
CC operation has the higher priority.
Every flag has an associated interrupt enable flag in interrupt enable register 0. The ISR0 register is cleared
by a hard reset or by leaving the configuration state.
MFR4200 Data Sheet, Rev. 0
114
Freescale Semiconductor
Memory Map and Registers
RXIF — Receive Interrupt Flag
This bit is set when any of the enabled (IENAn = 1) receive message buffers or the receive FIFO has
successfully received a frame. Sources of this interrupt are set IFLG bits (see Section 3.4.1, “Message
Buffer Control, Configuration and Status Register”) of the corresponding message buffers. If RXIE is set
(see Section 3.2.3.5.5, “Interrupt Enable Register 0 (IER0)”), a receive interrupt remains pending while
the RXIF flag is set.
1 – At least one receive message buffer is full.
0 – All receive message buffers are empty.
TXIF — Transmit Interrupt Flag
This read-only bit is set when any of the enabled (IENAn = 1) transmit message buffers is empty
(IFLG = 1). Sources of this interrupt are set IFLG bits (see Section 3.4.1, “Message Buffer Control,
Configuration and Status Register”) of the corresponding message buffers. If TXIE is set (see
Section 3.2.3.5.5, “Interrupt Enable Register 0 (IER0)”), an interrupt remains pending while this flag is set.
1 – At least one transmit message buffer is empty.
0 – All transmit message buffers are full.
CHIERRIF — CHI Error Interrupt Flag
This bit is set when a CHI error is detected. Sources of this interrupt are CHI errors in the CHIER register
(see Section 3.2.3.6.3, “CHI Error Register (CHIER)”). If CHIERRIF is set, an interrupt remains pending
while this flag is set.
1 – A CHI error was detected.
0 – No CHI error was detected.
RFNEIF — Receive FIFO Not Empty Interrupt Flag
This bit is set when the receive FIFO is not empty. If enabled, a FIFO not empty interrupt remains pending
while this flag is set. The flag will be cleared if the FIFO is empty and message buffer 0 is unlocked. The
CC sets this flag when the FIFO is not empty.
1 – Receive FIFO is not empty.
0 – Receive FIFO is empty.
RFOIF — Receive FIFO Overrun Interrupt Flag
This bit is set when a receive FIFO overrun occurs. If enabled, an interrupt remains pending while this flag
is set.
1 – A receive FIFO overrun has been detected.
0 – No receive FIFO overrun has occurred.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
115
MFR4200 FlexRay Communication Controller
CYCIF — Cycle Start Interrupt Flag
This bit is set when a communication cycle starts. If enabled, an interrupt remains pending while this flag
is set.
1 – A communication cycle started.
0 – No communication cycle started.
TIF0/TIF1 — Timer Interrupt Flag 0/1
This bit is set when:
• the result of the timer 0/1 interrupt calculation, based on the cycle base and repetition fields of the
timer interrupt configuration register 0 (see Section 3.2.3.9.1, “Timer Interrupt Configuration
Register 0 Cycle Set (TICR0CS)”), matches the current cycle counter value in the CCCV register
(see Section 3.2.3.4.2, “Current Cycle Counter Value Register (CCCVR)”);
• and the macrotick offset programmed in the timer interrupt configuration register 0 (see
Section 3.2.3.9.1, “Timer Interrupt Configuration Register 0 Cycle Set (TICR0CS)”) matches the
current macrotick value from CMCVR (see Section 3.2.3.4.3, “Current Macrotick Counter Value
Register (CMCVR)”).
If enabled, an interrupt remains pending while this flag is set.
1 – Timer 0/1 has reached the limit.
0 – Timer 0/1 has not reached the limit.
NOTE
After a hard reset, timer interrupt configuration registers are cleared. The
CC indicates timers interrupts (ISR0 = 0x00C0) immediately after the hard
reset, as the protocol engine provides cycle time and cycle counter values
equal to zero during the whole configuration state. No interrupt is indicated
to the host, as the interrupt enable register IER0 is also 0 after a hard reset.
MOCE — Missing Offset Correction error
This bit is set if an insufficient number of measurements is available for offset correction at the end of the
communication cycle (even and odd).
1 – Insufficient number of measurements available for offset correction.
0 – Sufficient number of measurements available for offset correction
BGS — Bus Guardian Status
This bit indicates bus guardian schedule monitoring errors on channel A and/or channel B. The host may
read the bus guardian status register BGSR (see Section 3.2.3.4.9, “Bus Guardian Status Register
(BGSR)”) to determine on which channel the error occurred. The host may reset BGS by writing a ‘1’.
1 – Bus guardian schedule monitoring error.
0 – No bus guardian schedule monitoring error
MFR4200 Data Sheet, Rev. 0
116
Freescale Semiconductor
Memory Map and Registers
SSINT — Slot Status Interrupt
This bit indicates that at least one slot status counter register SSCnR (see Section 3.2.3.5.7, “Slot Status
Counter n Register, n = [0:7] (SSCnR)”) that is enabled as an interrupt source via slot status counter
interrupt mask register SSCIMR (see Section 3.2.3.5.10, “Slot Status Counter Interrupt Mask Register
(SSCIMR)”) has been incremented.
1 – At least one slot status counter that is enabled as an interrupt source has been incremented.
0 – No slot status counter that is enabled as an interrupt source has been incremented.
MRCE — Missing Rate Correction error
This bit is set if an insufficient number of measurement pairs is available for rate correction at the end of
the odd communication cycle.
1 – Insufficient number of measurement pairs available for rate correction
0 – Sufficient number of measurement pairs available for rate correction
EHLC — Error Handling Level Changed/ Startup Interrupt detected
This signal indicates, to the host, changes to the error handling level.
1 – Error handling level has changed.
0 – Error handling level has not changed.
MAXSYNC — Max Sync Frames Detected
The controller sets this bit when more than the configured maximum number of sync frames (see
Section 3.2.3.3.5, “Maximum Sync Frames Register (MSFR)”) are detected within a single cycle. In this
case, the controller is not able to capture all time difference measurements.
1 – More than the configured maximum number of sync frames have been received.
0 – Not more than the configured maximum number of sync frames have been received.
CCLR — Clock Correction Limit Reached
This bit is set if offset or rate calculation reaches the threshold as configured in registers MOCR and
MRCR (see Section 3.2.3.3.24, “Maximum Offset Correction Register (MOCR)” and Section 3.2.3.3.25,
“Maximum Rate Correction Register (MRCR)”).
1 – Offset or rate calculation has reached the limit.
0 – Offset and rate correction are within the limit.
FATAL — Fatal Error
This bit is set if an illegal condition is detected in the protocol state machine; this can be caused by illegal
configuration. In this as, the controller goes into the diagnosis stop state immediately.
1 – Fatal error detected.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
117
MFR4200 FlexRay Communication Controller
0 – No fatal error detected.
3.2.3.6.7
Startup Interrupt Status Register (SISR)
Address 0x10
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
CDSTPNSIF
CDSTPNIF
PLFIF
CDSTMIF
r
r
r
r
rwh
rwh
rwh
rwh
Figure 3-79. Startup Interrupt Status Register
This register holds the interrupt flags related to the startup procedure. All flags are read/write for the host.
Each flag has an associated interrupt enable flag in the startup interrupt enable register (see
Section 3.2.3.5.1, “Startup Interrupt Enable Register (SIER)”). The SISR register is cleared during a hard
reset or when leaving the configuration state.
The host clears a status bit in the SISR by writing a '1' to it. Writing a ‘0’ does not change the bit state. The
CC sets a status bit in the SISR again when it detects the condition for that bit. If the host and the CC try
to access the SISR register at the same time, the CC operation has the higher priority.
CDSTMIF — Coldstart Max Interrupt Flag
This error signal is set if the maximum number of allowed retries of a coldstarting CC (CSMR
programmed value – see Section 3.2.3.3.26, “Coldstart Maximum Register (CSMR)”) is reached. That is,
if the CSMR register is programmed with the value N, the CC sets the CDSTMIF bit after the Nth retry
has failed. If enabled, an interrupt remains pending while this flag is set.
1 – Coldstart Maximum value has been reached.
0 – Coldstart Maximum value has not been reached.
PLFIF — Plausibility Failed Interrupt Flag
This error signal is set if the consistency check of the local CC within the startup sequence failed, i.e. the
number of received valid startup frames is less than required. If enabled, an interrupt remains pending
while this flag is set.
1 – A Plausibility Check of the local CC within the startup sequence failed.
0 – A Plausibility Check of the local CC within the startup sequence did not fail.
MFR4200 Data Sheet, Rev. 0
118
Freescale Semiconductor
Memory Map and Registers
CDSTPNSIF — Coldstart Path Noise Interrupt Flag
This signal is set if the CC has entered startup via the coldstart noise path. This indicates that the CC tried
to start the network. If enabled, an interrupt remains pending while this flag is set.
1 – The startup has been entered via the coldstart noise path.
0 – The startup has not been entered via the coldstart noise path.
CDSTPNIF — Coldstart Path Normal Interrupt Flag
This signal is set if the CC has entered the startup via the normal coldstart path. This indicates that the CC
tried to start the network. If enabled, an interrupt is pending while this flag is set.
1 – Startup has been entered via the normal coldstart path.
0 – Startup has not been entered via the normal coldstart path.
3.2.3.6.8
Slot Status n Register with n = [0:7] (SSnR)
Address SS0R=0x74, SS1R=0x76, SS2R=0x78, SS3R=0x7A, SS4R=0x7C, SS5R=0x7E, SS6R=0x80, SS7R=0x82
Reset 0x0
15
14
13
12
11
10
9
8
VCE_B
SYNCF_B
NULLF_B
SUPF_B
SERR_B
CERR_B
BVIOL_B
TXCON_B
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
VCE_A
SYNCF_A
NULLF_A
SUPF_A
SERR_A
CERR_A
BVIOL_A
TXCON_A
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-80. Slot Status n Register, n = [0:7]
Each of these registers holds the status of the slot specified in the corresponding slot status selection
register SSSnR for both channel A and channel B. The suffices “_A” and “_B” indicate whether the slot
status is valid for channel A or channel B, respectively. For a detailed description of the slot status flags,
refer to Section 3.3.3, “Message Buffer Slot Status Vector”.
The controller provides a pair of slot status registers for each monitored slot with the first register being
assigned to even communication cycles, and the second to odd communication cycles, as shown in
Table 3-8.
The controller clears the slot status registers SSnR (see Section 3.2.3.6.8, “Slot Status n Register with
n = [0:7] (SSnR)”) when leaving the configuration state.
•
•
NOTE
Refer to Table 3-4 for slot status monitoring availability in different
protocol states.
The slot status of slot n is updated within the first macrotick of slot n+1.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
119
MFR4200 FlexRay Communication Controller
•
Empty slots exhibit the slot status 0x00 for both channels, because the
slot status registers SSnR do not include the slot status channel bit.
Table 3-8. Mapping between SSSnR and SSnR
Even communication cycle
Slot Status
Selection Register
3.2.3.6.9
Odd communication cycle
Channel A
(low byte)
Channel B
(high byte)
Channel A
(low byte)
Channel B
(high byte)
SSS0R
SS0R
SS0R
SS1R
SS1R
SSS1R
SS2R
SS2R
SS3R
SS3R
SSS2R
SS4R
SS4R
SS5R
SS5R
SSS3R
SS6R
SS6R
SS7R
SS7R
Odd Sync Frame ID n Register, n = [0:15] (OSFIDnR)
Address OSFID0R=0x3E0 … OSFID15R=0x3FE
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
ID10
ID9
ID8
r
r
r
r
r
rh
rh
rh
7
6
5
4
3
2
1
0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-81. Odd Sync Frame ID n Register, n = [0:15]
These registers hold the frame IDs of all sync frames received in odd communication cycles and used for
clock synchronization. The CC does not change the odd ID values from the end of the static part in the odd
cycle to the beginning of the NIT in the even communication cycle.
NOTE
If a CC is configured to send sync frames (see Section 3.2.3.3.29, “Sync
Frame Register (SYNCFR)”), the CC will store its sync frame ID in register
OSFID0R.
MFR4200 Data Sheet, Rev. 0
120
Freescale Semiconductor
Memory Map and Registers
3.2.3.6.10
Even Sync Frame ID n Register, n = [0:15] (ESFIDnR)
Address EID0R=0x380 … EID15R=0x39E
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
ID10
ID9
ID8
r
r
r
r
r
rh
rh
rh
7
6
5
4
3
2
1
0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-82. Even Sync Frame ID n Register, n = [0:15]
These registers hold the slot IDs of all sync frames received in even communication cycles and used for
clock synchronization. The CC does not change the even ID values from the end of the static part in the
even cycle to the beginning of the NIT in the odd communication cycle.
NOTE
If a CC is configured to send sync frames (see Section 3.2.3.3.29, “Sync
Frame Register (SYNCFR)), each time the CC clears the EMCR or OMCR,
it:
•
•
•
initializes the ESFID0R (or OSFID0R) with its sync frame ID,
increments EMCR or OMCR,
initializes EMA0R and EMB0R or OMA0R and EMB0R with the
following value:
NMLR * SSAPOR – TSSLR * BDR – max(DCAR,DCBR) – 4
3.2.3.6.11
Eqn. 3-10
Odd Measurement Channel A n Register, n = [0:15] (OMAnR)
Address OMA0R=0x3A0 … OMA15R=0x3BE
Reset undefined state
15
14
13
12
11
10
9
8
OMA15
OMA14
OMA13
OMA12
OMA11
OMA10
OMA9
OMA8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
OMA7
OMA6
OMA5
OMA4
OMA3
OMA2
OMA1
OMA0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-83. Odd Measurement Channel A n Register, n = [0:15]
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
121
MFR4200 FlexRay Communication Controller
These registers hold the sync frame arrival time measured in microticks relative to the slot start boundary.
Registers OMA0R to OMA15R contain all measurement values from channel A for the odd
communication cycle.
3.2.3.6.12
Odd Measurement Channel B n Register, n = 0:15] (OMBnR)
Address OMB0R=0x3C0 … OMB15R=0x3DE
Reset undefined state
15
14
13
12
11
10
9
8
OMB15
OMB14
OMB13
OMB12
OMB11
OMB10
OMB9
OMB8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
OMB7
OMB6
OMB5
OMB4
OMB3
OMB2
OMB1
OMB0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-84. Odd Measurement Channel B n Register, n = [0:15]
These registers hold the sync frame arrival time measured in microticks relative to the slot start boundary.
Registers OMB0R to OMB15R contain all measurement values from channel B for the odd
communication cycle.
3.2.3.6.13
Even Measurement Channel A n Register, n = [0:15] (EMAnR)
Address EMA0R=0x340 … EMA15R=0x35E
Reset undefined state
15
14
13
12
11
10
9
8
EMA15
EMA14
EMA13
EMA12
EMA11
EMA10
EMA9
EMA8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
EMA7
EMA6
EMA5
EMA4
EMA3
EMA2
EMA1
EMA0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-85. Even Measurement Channel A n Register, n = [0:15]
These registers hold the sync frame arrival time measured in microticks relative to the slot start boundary.
Registers EMA[0:15]R contain all measurement values from channel A for the even communication cycle.
MFR4200 Data Sheet, Rev. 0
122
Freescale Semiconductor
Memory Map and Registers
3.2.3.6.14
Even Measurement Channel B n Register, n = [0:15] (EMBnR)
Address EMB0R=0x360 … EMB15R=0x37E
Reset undefined state
15
14
13
12
11
10
9
8
EMB15
EMB14
EMB13
EMB12
EMB11
EMB10
EMB9
EMB8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
EMB7
EMB6
EMB5
EMB4
EMB3
EMB2
EMB1
EMB0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-86. Even Measurement Channel B n Register, n = [0:15]
These registers hold the sync frame arrival time measured in microticks relative to the slot start boundary.
Registers EMB[0:15]R contain all measurement values from channel B for the even communication cycle.
NOTE
To get the time difference based on the expected time reference point, one
must subtract the nominal action point offset in microticks, the frame start
sequence length and the delay compensation according to the formula
below:
Time difference = (EMAnR, EMBnR, OMAnR, or OMBnR) – NMLR * SSAPOR
– TSSLR * BDR – max(DCAR,DCBR) – 4
Eqn. 3-11
As the transmission start sequence length is given in bits, it must be converted to µT by multiplying it by
the bit duration. As the channel information is not available for the list of sync frame arrival times, the CC
standardizes the values based on the channel with the larger delay compensation value; thereby, the frame
arrival time is always positive.
A sync frame arrival time of 0 in one of the measurement registers denotes an invalid time difference. For
example, if, in a given slot, only a sync frame on channel A has been received, the corresponding EMBnR
will hold the value 0.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
123
MFR4200 FlexRay Communication Controller
3.2.3.6.15
Even Measurement Counter Register (EMCR)
Address 0x33C
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
EMC3
EMC2
EMC1
EMC0
r
r
r
r
rh
rh
rh
rh
Figure 3-87. Even Measurement Counter Register
The EMCR and OMCR are described in the following section.
3.2.3.6.16
Odd Measurement Counter Register (OMCR)
Address 0x33E
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
OMC3
OMC2
OMC1
OMC0
r
r
r
r
rh
rh
rh
rh
Figure 3-88. Odd Measurement Counter Register
The EMCR and OMCR hold the number of valid sync frames received during the static segment of an even
or odd cycle, respectively. If sync frame filtering is enabled, only sync frames that have passed the sync
frame rejection and/or acceptance filters (see Section 3.2.3.8.3, “Sync Frame Rejection Filter Register
(SYNFRFR)” and Section 3.2.3.8.1, “Sync Frame Acceptance Filter Value Register (SYNFAFVR)”) are
considered. The EMCR and OMCR registers hold the number of valid measurements in the measurement
tables (see Section 3.2.3.6.9, “Odd Sync Frame ID n Register, n = [0:15] (OSFIDnR)” and
Section 3.2.3.6.11, “Odd Measurement Channel A n Register, n = [0:15] (OMAnR)”). For example, if the
value of EMCR is two, then two valid sync frames are available for clock sync calculations; the remaining
fourteen values in the measurement table for the even cycle are invalid and may have undefined content.
The EMCR and OMCR counters are incremented each time, when a valid sync frame has been received
on at least one of the channels.
EMCR and OMCR are reset when the CC enters the initialize schedule and coldstart collision resolution
states. In the normal active state and the normal passive state, EMCR is reset in the NIT of the odd cycle,
and OMCR is reset at the end of the even cycle. If the node is a non sync node, EMCR and OMCR are
MFR4200 Data Sheet, Rev. 0
124
Freescale Semiconductor
Memory Map and Registers
reset to zero. If the node is a sync node, EMCR and OMCR are reset to 1, as a sync node considers its own
sync frames as zero values in the measurement tables.
3.2.3.7
3.2.3.7.1
Message Buffers and FIFO Configuration Related Registers
FIFO Size Register (FSIZR)
Address 0x18
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
FSIZ5
FSIZ4
FSIZ3
FSIZ2
FSIZ1
FSIZ0
r
r
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-89. FIFO Size Register
This register is used to configure the FIFO. The number of message buffers assigned to the receive FIFO,
starting from message buffer 0, can be selected. Writing the FSIZR register is possible only during the
configuration state.
Table 3-9. FIFO Size
FSIZ[5:0]
FIFO Size
000000
No FIFO is defined
000001
only message buffer 0
000010
message buffer 0…message buffer 1
000011
message buffer 0…message buffer 2
…
…
111001
message buffer 0…message buffer 56
111010
message buffer 0…message buffer 57
others
message buffer 0…message buffer 58
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
125
MFR4200 FlexRay Communication Controller
3.2.3.7.2
Message Buffer Control, Configuration and Status n Register, n = [0:58]
(BUFCSnR)
Address BUFCS0R=0x200, BUFCS1R=0x204, …, BUFCS57R=0x2E4, BUFCS58R=0x2E8.
BUFCSnR=0x200 + 0x4*dec2hex(n)
Reset IFLG, IENA, CFG and VALID bits are reset to 0, others – in undefined state
15
14
13
12
11
10
9
8
VALID
TT
CCFE
BT
DATUPD
CHB
CHA
BUFCMT
*
*
*
*
*
*
*
*
7
6
5
4
3
2
1
0
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
r
*
r
r
*
*
r
*
Figure 3-90. Message Buffer Control, Configuration and Status n Register, n = [0:58]
For a description of these registers and the bit access scheme, see Section 3.4.1, “Message Buffer Control,
Configuration and Status Register”.
3.2.3.7.3
Active Transmit Buffer Frame ID Register (ATBFRID)
Address 0x180
Reset undefined state
15
14
13
12
11
10
9
8
R*
PP
NFI
SYNC
STARTUP
ID10
ID9
ID8
rw
rw*
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-91. Active Transmit Buffer Frame ID Register
For a description of this register and the bit access scheme, refer to Section 3.5, “Message Buffer Handling
and Operations”.
MFR4200 Data Sheet, Rev. 0
126
Freescale Semiconductor
Memory Map and Registers
3.2.3.7.4
Active Transmit Buffer Cycle Counter and Payload Length Register
(ATBCCPLR)
Address 0x182
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
CYCL_CNT5
CYCL_CNT4
CYCL_CNT3
CYCL_CNT2
CYCL_CNT1
CYCL_CNT0
r
r
r*
r*
r*
r*
r*
r*
7
6
5
4
3
2
1
0
Reserved
LEN6
LEN5
LEN4
LEN3
LEN2
LEN1
LEN0
r
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-92. Active Transmit Buffer Cycle Counter and Payload Length Register
NOTE
The host may read the CYCL_CNT[5:0] bits but, as those bits are not
updated by the CC, they will be in an undefined state.
For a description of this register and the bit access scheme, refer to Section 3.5, “Message Buffer Handling
and Operations”.
3.2.3.7.5
Active Transmit Buffer Header CRC Register (ATBCRCR)
Address 0x184
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
HCRC10
HCRC9
HCRC8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
HCRC7
HCRC6
HCRC5
HCRC4
HCRC3
HCRC2
HCRC1
HCRC0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-93. Active Transmit Buffer Header CRC Register
For a description of this register and the bit access scheme, refer to Section 3.5, “Message Buffer Handling
and Operations”.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
127
MFR4200 FlexRay Communication Controller
3.2.3.7.6
Active Transmit Buffer Data n Register, n = [0:15] (ATBDATAnR)
Address ATBDATA0R=0x186 … ATBDATA15R=0x1A4
Reset undefined state
15
14
13
12
11
10
9
DATA(2n+1)15 DATA(2n+1)14 DATA(2n+1)13 DATA(2n+1)12 DATA(2n+1)11 DATA(2n+1)10 DATA(2n+1)9
8
DATA(2n+1)8
rw
rw
rw
rw
rw
rw
rw
rw
7
6
5
4
3
2
1
0
DATA(2n)7
DATA(2n)6
DATA(2n)5
DATA(2n)4
DATA(2n)3
DATA(2n)2
DATA(2n)1
DATA(2n)0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-94. Active Transmit Buffer Data n Register, n = [0:15]
For a description of these registers, refer to Section 3.5, “Message Buffer Handling and Operations”.
3.2.3.7.7
Active Transmit Buffer Message Buffer Slot Status Vector Register
(ATBMBSSVR)
Address 0x1A6
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
CH
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
r
r
r
r
r
r
r
rh
Figure 3-95. Active Transmit Buffer Message Buffer Slot Status Vector Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
MFR4200 Data Sheet, Rev. 0
128
Freescale Semiconductor
Memory Map and Registers
3.2.3.7.8
Active Receive Buffer Frame ID Register (ARBFRID)
Address 0x140
Reset undefined state
15
14
13
12
11
10
9
8
R*
PP
NFI
SYNC
STARTUP
ID10
ID9
ID8
rh
rh
rh
rh
rh
rw*
rw*
rw*
7
6
5
4
3
2
1
0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-96. Active Receive Buffer Frame ID Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
3.2.3.7.9
Active Receive Buffer Cycle Counter and Payload Length Register
(ARBCCPLR)
Address 0x142
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
CYCL_CNT5
CYCL_CNT4
CYCL_CNT3
CYCL_CNT2
CYCL_CNT1
CYCL_CNT0
r
r
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
Reserved
LEN6
LEN5
LEN4
LEN3
LEN2
LEN1
LEN0
r
rh
rh
rh
rh
rh
rh
rh
Figure 3-97. Active Receive Buffer Cycle Counter and Payload Length Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
129
MFR4200 FlexRay Communication Controller
3.2.3.7.10
Active Receive Buffer Header CRC Register (ARBCRCR)
Address 0x144
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
HCRC10
HCRC9
HCRC8
r
r
r
r
r
rh
rh
rh
7
6
5
4
3
2
1
0
HCRC7
HCRC6
HCRC5
HCRC4
HCRC3
HCRC2
HCRC1
HCRC0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-98. Active Receive Buffer Header CRC Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
3.2.3.7.11
Active Receive Buffer Data n Register, n = [0:15] (ARBDATAnR)
Address ARBDATA0R=0x146 … ARBDATA15R=0x164
Reset undefined state
15
14
13
12
11
10
9
DATA(2n+1)15 DATA(2n+1)14 DATA(2n+1)13 DATA(2n+1)12 DATA(2n+1)11 DATA(2n+1)10 DATA(2n+1)9
8
DATA(2n+1)8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
DATA(2n)7
DATA(2n)6
DATA(2n)5
DATA(2n)4
DATA(2n)3
DATA(2n)2
DATA(2n)1
DATA(2n)0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-99. Active Receive Buffer Data n Register, n = [0:15]
For a description of these registers, refer to Section 3.5, “Message Buffer Handling and Operations”.
MFR4200 Data Sheet, Rev. 0
130
Freescale Semiconductor
Memory Map and Registers
3.2.3.7.12
Active Receive Buffer Message Buffer Slot Status Vector Register
(ARBMBSSVR)
Address 0x166
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
CH
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
rh
rh
rh
rh
rh
rh
rh
r
Figure 3-100. Active Receive Buffer Message Buffer Slot Status Vector Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
3.2.3.7.13
Active FIFO Buffer Frame ID Register (AFBFRID)
Address 0x100
Reset undefined state
15
14
13
12
11
10
9
8
R*
PP
NFI
SYNC
STARTUP
ID10
ID9
ID8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-101. Active FIFO Buffer Frame ID Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
131
MFR4200 FlexRay Communication Controller
3.2.3.7.14
Active FIFO Buffer Cycle Counter and Payload Length Register (AFBCCPLR)
Address 0x102
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
CYCL_CNT5
CYCL_CNT4
CYCL_CNT3
CYCL_CNT2
CYCL_CNT1
CYCL_CNT0
r
r
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
Reserved
LEN6
LEN5
LEN4
LEN3
LEN2
LEN1
LEN0
r
rh
rh
rh
rh
rh
rh
rh
Figure 3-102. Active FIFO Buffer Cycle Counter and Payload Length Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
3.2.3.7.15
Active FIFO Buffer Header CRC Register (AFBCRCR)
Address 0x104
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
HCRC10
HCRC9
HCRC8
r
r
r
r
r
rh
rh
rh
7
6
5
4
3
2
1
0
HCRC7
HCRC6
HCRC5
HCRC4
HCRC3
HCRC2
HCRC1
HCRC0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-103. Active FIFO Buffer Header CRC Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
MFR4200 Data Sheet, Rev. 0
132
Freescale Semiconductor
Memory Map and Registers
3.2.3.7.16
Active FIFO Buffer Data n Register, n = [0:15] (AFBDATAnR)
Address ARFBDATA0R=0x106 … ARFBDATA15R=0x124
Reset undefined state
15
14
13
12
11
10
9
DATA(2n+1)15 DATA(2n+1)14 DATA(2n+1)13 DATA(2n+1)12 DATA(2n+1)11 DATA(2n+1)10 DATA(2n+1)9
8
DATA(2n+1)8
rh
rh
rh
rh
rh
rh
rh
rh
7
6
5
4
3
2
1
0
DATA(2n)7
DATA(2n)6
DATA(2n)5
DATA(2n)4
DATA(2n)3
DATA(2n)2
DATA(2n)1
DATA(2n)0
rh
rh
rh
rh
rh
rh
rh
rh
Figure 3-104. Active FIFO Buffer Data n Register, n = [0:15]
For a description of these registers, refer to Section 3.5, “Message Buffer Handling and Operations”.
3.2.3.7.17
Active FIFO Buffer Message Buffer Slot Status Vector Register (AFBMBSSVR)
Address 0x126
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
CH
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
rh
rh
rh
rh
rh
rh
rh
r
Figure 3-105. Active FIFO Buffer Message Buffer Slot Status Vector Register
For a description of this register, refer to Section 3.5, “Message Buffer Handling and Operations”.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
133
MFR4200 FlexRay Communication Controller
3.2.3.8
3.2.3.8.1
Filtering Related Registers
Sync Frame Acceptance Filter Value Register (SYNFAFVR)
Address 0xF0
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
SYNFAFV10
SYNFAFV9
SYNFAFV8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
SYNFAFV7
SYNFAFV6
SYNFAFV5
SYNFAFV4
SYNFAFV3
SYNFAFV2
SYNFAFV1
SYNFAFV0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-106. Sync Frame Acceptance Filter Value Register
If ENSYNFF bit is set (see Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”), every valid
sync frame with the identifier ID must fulfill the following condition before its arrival time measurement
values can be used for the clock synchronization.
An identifier is accepted when:
( NOT((ID XOR SynFAFV) AND SynFAFM) AND NOT(ID == SynFRF) ) == TRUE
Eqn. 3-12
This register may be written only in the configuration state.
3.2.3.8.2
Sync Frame Acceptance Filter Mask Register (SYNFAFMR)
Address 0xEE
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
SYNFAFM10
SYNFAFM9
SYNFAFM8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
SYNFAFM7
SYNFAFM6
SYNFAFM5
SYNFAFM4
SYNFAFM3
SYNFAFM2
SYNFAFM1
SYNFAFM0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-107. Sync Frame Acceptance Filter Mask Register
SYNFAFM[10:0]
0 – This bit position is “don't care” for acceptance.
1 – This bit of the identifier must be identical to the corresponding bit in the acceptance value, for it to be
accepted by the sync frame acceptance filter.
This register may be written only in the configuration state.
MFR4200 Data Sheet, Rev. 0
134
Freescale Semiconductor
Memory Map and Registers
3.2.3.8.3
Sync Frame Rejection Filter Register (SYNFRFR)
Address 0xF2
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
SYNFRF10
SYNFRF9
SYNFRF8
r
r
r
r
r
rw
rw
rw
7
6
5
4
3
2
1
0
SYNFRF7
SYNFRF6
SYNFRF5
SYNFRF4
SYNFRF3
SYNFRF2
SYNFRF1
SYNFRF0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-108. Sync Frame Rejection Filter Register
If the ENSYNFF bit is set (see Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”), this
register is used to identify a sync frame ID whose arrival time measurement values are to be rejected for
clock synchronization. Note that this register can be written at any time by the host, unlike SYNFAFMR
and SYNFAFVR (see Section 3.2.3.8.2, “Sync Frame Acceptance Filter Mask Register (SYNFAFMR)”
and Section 3.2.3.8.1, “Sync Frame Acceptance Filter Value Register (SYNFAFVR)”).
NOTE
To ensure correct operation of the CC, the host should update this register
only during the NIT.
3.2.3.8.4
Cycle Counter Filter n Register, n = [0:58] (CCFnR)
Address CCF0R=0x202, CCF1R=0x206, …, CCF57R=0x2E6, CCF58R=0x2EA.
CCFnR=0x202 + 0x4*dec2hex(n)
Reset undefined state
15
14
13
12
11
10
9
8
Reserved
Reserved
CCM5
CCM4
CCM3
CCM2
CCM1
CCM0
r
r
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
Reserved
Reserved
CCV5
CCV4
CCV3
CCV2
CCV1
CCV0
r
r
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-109. Cycle Counter Filter n Register, n = [0:58]
Each cycle counter filter register is related to an appropriate message buffer: CCF0R to message buffer 0,
CCF1R to message buffer 1, … , CCF58R to message buffer 58. (For more information, refer to Section ,
“Receive, receive FIFO, and transmit message buffers are accessible to the host MCU only through the
active receive, active transmit, and active receive FIFO buffers.”).
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
135
MFR4200 FlexRay Communication Controller
CCV[0:5] — Cycle Count Value n Bit[0:5]
These bits determine the cycle count value to be used for the cycle filtering.
CCM[0:5] — Cycle Count Mask n Bit[0:5]
These bits define the mask used in the filtering process.
0 – This bit of the cycle counter is not used for filtering.
1 – This bit of the cycle counter is used for filtering.
For a description of the read and write character of each bit-field, refer to Section 3.4.1, “Message Buffer
Control, Configuration and Status Register” and Section 3.4.2, “Message Buffer Filter Registers”.
3.2.3.8.5
FIFO Acceptance Filter Message ID Value Register (FAFMIDVR)
Address 0x1C
Reset 0x0
15
14
13
12
11
10
9
8
FMDAFV15
FMDAFV14
FMDAFV13
FMDAFV12
FMDAFV11
FMDAFV10
FMDAFV9
FMDAFV8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
FMDAFV7
FMDAFV6
FMDAFV5
FMDAFV4
FMDAFV3
FMDAFV2
FMDAFV1
FMDAFV0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-110. FIFO Acceptance Filter Message ID Value Register
FMDAFV[0:15]
These bit-fields define the FIFO message ID filter value, for comparison with the message ID field of
received frames. It defines the acceptable pattern value of the message ID to be received. These bits may
be written only in the configuration state.
3.2.3.8.6
FIFO Acceptance Filter Message ID Mask Register (FAFMIDMR)
Address 0x1E
Reset 0x0
15
14
13
12
11
10
9
8
FMDAFM15
FMDAFM14
FMDAFM13
FMDAFM12
FMDAFM11
FMDAFM10
FMDAFM9
FMDAFM8
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
7
6
5
4
3
2
1
0
FMDAFM7
FMDAFM6
FMDAFM5
FMDAFM4
FMDAFM3
FMDAFM2
FMDAFM1
FMDAFM0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-111. FIFO Acceptance Filter Message ID Mask Register
MFR4200 Data Sheet, Rev. 0
136
Freescale Semiconductor
Memory Map and Registers
FMDAFM[0:15]
These bit-fields define the mask for the FIFO message ID filter.
0 – This bit in the message ID field of a received frame is not considered for acceptance filtering.
1 – This bit in the message ID field of a received frame is used for the acceptance filtering.
These bits may be written only in the configuration state.
3.2.3.8.7
FIFO Acceptance/Rejection Filter Channel Register (FAFCHR)
Address 0x1A
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
FCHBAFV
FCHAAFV
r
r
r
r
r
r
rw*
rw*
Figure 3-112. FIFO Acceptance/Rejection Filter Channel Register
FCHAAFV, FCHBAFV
These are FIFO channel filtering value bits. They define the channel from which the received frame will
be accepted or rejected. These bits may be written only in the configuration state.
Table 3-10. FIFO Channel Filtering Configuration
Receive message buffer
Store valid Rx frame
FCHAAFV
FCHBAFV
1
1
Frame received on both channels are accepted or rejected
1
0
Frame received on channel A is accepted or rejected
0
1
Frame received on channel B is accepted or rejected
0
0
Ignore frame
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
137
MFR4200 FlexRay Communication Controller
3.2.3.8.8
FIFO Rejection Filter Frame ID Value Register (FRFFIDVR)
Address 0x20
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
FFIDRFV10
FFIDRFV9
FFIDRFV8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
FFIDRFV7
FFIDRFV6
FFIDRFV5
FFIDRFV4
FFIDRFV3
FFIDRFV2
FFIDRFV1
FFIDRFV0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-113. FIFO Rejection Filter Frame ID Value Register
FFIDRFV[0:10]
This field contains the FIFO frame ID rejection filter value, for comparison with frame ID fields of
received frames. It defines the acceptable pattern value of the frame ID to be rejected. These bits may be
written only in the configuration state.
3.2.3.8.9
FIFO Rejection Filter Frame ID Mask Register (FRFFIDMR)
Address 0x22
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
FFIDRFM10
FFIDRFM9
FFIDRFM8
r
r
r
r
r
rw*
rw*
rw*
7
6
5
4
3
2
1
0
FFIDRFM7
FFIDRFM6
FFIDRFM5
FFIDRFM4
FFIDRFM3
FFIDRFM2
FFIDRFM1
FFIDRFM0
rw*
rw*
rw*
rw*
rw*
rw*
rw*
rw*
Figure 3-114. FIFO Rejection Filter Frame ID Mask Register
FFIDRFM[0:10]
These bit-fields indicate the mask for the FIFO Rejection frame ID filter.
0 – This bit of the internal slot ID (when a frame was received) is not considered for the rejection filtering.
1 – This bit of the internal slot ID (when a frame was received) is used for the rejection filtering.
These bits may be written only in the configuration state.
MFR4200 Data Sheet, Rev. 0
138
Freescale Semiconductor
Memory Map and Registers
3.2.3.9
Timer Related Registers
The CC provides two timers with timer interrupt configuration registers for setting interrupts for specific
points of global time. Each timer contains two parameters:
1. Cycle Set: A 9-bit register is used to specify in which set of communication cycles the interrupt
will occur. It consists of two fields, the base cycle [b] and the cycle repetition [c]. The set of cycle
numbers where the interrupt is to generated is determined from these two fields using the formula:
b + n*2^c (n = 0, 1, 2, …)
Eqn. 3-13
where:
— b is a 6-bit cycle number used to identify the initial value for generating the cycle set.
— c is a 3-bit value used to determine a constant repetition factor to be added to the base cycle
(c = 0 … 6)
— b must be smaller than 2^c:
b<2^c.
Eqn. 3-14
2. Macrotick Offset: This 16-bit value is the macrotick offset from the beginning of the cycle in
which the interrupt is to occur. The interrupt occurs at this offset for each cycle in the interrupt
cycle set.
3.2.3.9.1
Timer Interrupt Configuration Register 0 Cycle Set (TICR0CS)
Address 0x30
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
CR2
CR1
CR0
r
r
r
r
r
rw
rw
rw
7
6
5
4
3
2
1
0
Reserved
Reserved
BCT5
BCT4
BCT3
BCT2
BCT1
BCT0
r
r
rw
rw
rw
rw
rw
rw
Figure 3-115. Timer Interrupt Configuration Register 0 Cycle Set
This register holds base cycle and cycle repetition values for timer 0.
A hard reset clears the register.
BCT[0:5]
Base cycle value for timer 0.
CR[0:2]
Cycle repetition value for timer 0.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
139
MFR4200 FlexRay Communication Controller
3.2.3.9.2
Timer Interrupt Configuration Register 0 Macrotick Offset (TICR0MO)
Address 0x32
Reset 0x0
15
14
13
12
11
10
9
8
MO15
MO14
MO13
MO12
MO11
MO10
MO9
MO8
rw
rw
rw
rw
rw
rw
rw
rw
7
6
5
4
3
2
1
0
MO7
MO6
MO5
MO4
MO3
MO2
MO1
MO0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-116. Timer Interrupt Configuration Register 0 Macrotick Offset
This register holds the macrotick offset value for timer 0. A hard reset clears the register.
3.2.3.9.3
Timer Interrupt Configuration Register 1 Cycle Set (TICR1CS)
Address 0x34
Reset 0x0
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
CR2
CR1
CR0
r
r
r
r
r
rw
rw
rw
7
6
5
4
3
2
1
0
Reserved
Reserved
BCT5
BCT4
BCT3
BCT2
BCT1
BCT0
r
r
rw
rw
rw
rw
rw
rw
Figure 3-117. Timer Interrupt Configuration Register 1 Cycle Set
This register holds base cycle and cycle repetition values for timer 1.
A hard reset clears the register.
BCT[0:5]
Base cycle value for timer 1.
CR[0:2]
Cycle repetition value for timer 1.
MFR4200 Data Sheet, Rev. 0
140
Freescale Semiconductor
Message Buffer
3.2.3.9.4
Timer Interrupt Configuration Register 1 Macrotick Offset (TICR1MO)
Address 0x36
Reset 0x0
15
14
13
12
11
10
9
8
MO15
MO14
MO13
MO12
MO11
MO10
MO9
MO8
rw
rw
rw
rw
rw
rw
rw
rw
7
6
5
4
3
2
1
0
MO7
MO6
MO5
MO4
MO3
MO2
MO1
MO0
rw
rw
rw
rw
rw
rw
rw
rw
Figure 3-118. Timer Interrupt Configuration Register 1 High
The timer interrupt configuration register 1 macrotick offset holds the macrotick offset value for timer 1.
A hard reset clears the register.
3.3
Message Buffer
Receive, receive FIFO, and transmit message buffers are accessible to the host MCU only through the
active receive, active transmit, and active receive FIFO buffers.
3.3.1
Message Buffer Layout
The layout shown in below, apply to transmit, receive buffer, and FIFO buffers.
Table 3-11. Receive Message Buffer Layout
0
1
2
15
14
13
12
11
R*
PP
NFI
SYNC
START UP
Frame ID (11 bits)
RO
RO
RO
RO
RO
RO_NO/WR_CS
R NU
10
Cycle Count (6 bits) RO
R NU
9
8
7
6
5
R NU
4
3
2
0
PayloadLength (7 bits) RO
Header CRC (11 bits) RO
3
Message ID1/Data1/NMVector1 RO
Message ID0/Data0/NMVector0 RO
4
Data3/NMVector3 RO
Data2/NMVector2 RO
5
Data5/NMVector5 RO
Data4/NMVector4 RO
6
Data7/NMVector7 RO
Data6/NMVector6 RO
7
Data9/NMVector9 RO
Data8/NMVector8 RO
8
Data11/NMVector11 RO
Data10/NMVector10 RO
9
Data13 RO
Data12 RO
…
… RO
… RO
18
Data31 RO
Data30 RO
19
1
Message Buffer Slot Status Vector RO
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
141
MFR4200 FlexRay Communication Controller
Table 3-12. Receive FIFO Message Buffer Layout
0
1
15
14
13
12
11
R*
PP
NFI
SYNC
START UP
Frame ID (11 bits)
RO
RO
RO
RO
RO
RO
R NU
10
9
8
Cycle Count (6 bits) RO
2
7
6
5
R NU
R NU
4
3
2
1
0
PayloadLength (7 bits) RO
Header CRC (11 bits) RO
3
Message ID1/Data1/NMVector1RO
Message ID0/Data0/NMVector0 RO
4
Data3/NMVector3RO
Data2/NMVector2 RO
5
Data5/NMVector5 RO
Data4/NMVector4 RO
6
Data7/NMVector7 RO
Data6/NMVector6 RO
7
Data9/NMVector9 RO
Data8/NMVector8 RO
8
Data11/NMVector11 RO
Data10/NMVector10 RO
9
Data13 RO
Data12 RO
…
… RO
… RO
18
Data31 RO
Data30 RO
19
Message Buffer Slot Status Vector RO
Table 3-13. Transmit Message Buffer Layout
15
0
1
2
14
13
12
11
R*
PP
NFI
SYNC
START UP
Frame ID (11 bits)
WR
TX_CS_NO
NU
NU
NU
TX_CS_NO
R NU
10
Cycle Count (6 bits) NU
R NU
9
8
7
6
R NU
5
4
3
2
1
PayloadLength (7 bits) TX_CS_NO
Header CRC (11 bits) TX_CS_NO
3
Message ID1/Data1/NMVector1 WR
Message ID0/Data0/NMVector0 WR
4
Data3/NMVector3 WR
Data2/NMVector2 WR
5
Data5/NMVector5 WR
Data4/NMVector4
6
Data7/NMVector7 WR
Data6/NMVector6 WR
7
Data9/NMVector9 WR
Data8/NMVector8 WR
8
Data11/NMVector11 WR
Data10/NMVector10 WR
9
Data13 WR
Data12 WR
…
… WR
… WR
18
Data31 WR
Data30 WR
19
0
Message Buffer Slot Status Vector RO
NOTE
The host cannot access the CC part of a double transmit message buffer. CC
raises a locking error if the host tries to lock the CC part of a double transmit
message buffer.
MFR4200 Data Sheet, Rev. 0
142
Freescale Semiconductor
Message Buffer
Where:
RO_NO/WR_CS
TX_CS_NO
Host read access; host write access during the configuration state only
Host read access; host write access:
– during the configuration state for all transmit message buffers
– during normal mode of operation for buffers configured for the dynamic segment of the
communication cycle (read-only access for static segment buffers)
RO
Host read-only access
WR
Host read/write access
NU
Reserved or read-only bits not used by the CC during operation
The size of the data field in the MFR4200 is limited to 32 bytes.
Table 3-14. Mapping between Buffer Layout and Active Receive/Transmit/FIFO Message Buffers
Active FIFO/Receive/Transmit
Message Buffers Register
Message Buffer Layout
R P N SYN STAR
* P FI C
T UP
R
Cycle Count (6 bits)
R
Frame ID (11 bits)
R
PayloadLength (7
bits)
Header CRC (11 bits)
Active FIFO/Receive/Transmit Buffer Frame ID Register
Active FIFO/Receive/Transmit Buffer Cycle Counter and Payload
Length Register
Active FIFO/Receive/Transmit Buffer Header CRC Register
Message
ID1/Data1/NMVector1
Message
ID0/Data0/NMVector0
Active FIFO/Receive/Transmit Buffer Data 0 Register
Data3/NMVector3
Data2/NMVector2
Active FIFO/Receive/Transmit Buffer Data 1 Register
Data5/NMVector5
Data4/NMVector4
Active FIFO/Receive/Transmit Buffer Data 2 Register
Data7/NMVector7
Data6/NMVector6
Active FIFO/Receive/Transmit Buffer Data 3 Register
Data9/NMVector9
Data8/NMVector8
Active FIFO/Receive/Transmit Buffer Data 4 Register
Data11/NMVector11
Data10/NMVector10
Active FIFO/Receive/Transmit Buffer Data 5 Register
Data13
Data12
Active FIFO/Receive/Transmit Buffer Data 6 Register
…
…
Data31
Data30
…
Message Buffer Slot Status Vector
3.3.2
3.3.2.1
Active FIFO/Receive/Transmit Buffer Data 15 Register
Active FIFO/Receive/Transmit Buffer Message Buffer Slot Status
Vector Register
Message Buffer Field Descriptions
ID[10:0] — Frame ID Field
Each transmit and receive message buffer and the FIFO buffer contains a frame ID field. This field is
interpreted differently for receive message buffers, transmit message buffers, and the receive FIFO.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
143
MFR4200 FlexRay Communication Controller
Receive message buffers:
The Frame ID field contains a frame ID filtering value. A received frame is stored in the first receive
message buffer with a filter matching the received frame ID. The channel and cycle counter receive
filtering criteria must also be met.
Transmit message buffers:
The frame ID field in the message buffer is used to determine the appropriate slot for frame transmission.
The frame is transmitted in the time slot corresponding to the frame ID, provided the channel and cycle
counter criteria are also met.
Receive FIFO message buffer:
The frame ID field in each element of the receive FIFO buffer stores a received frame ID value, if the frame
is accepted by the FIFO acceptance filter and not rejected by the FIFO rejection filter and if there is no
matching dedicated receive message buffer. For more information on FIFO filters, refer to Section 3.2.3.8,
“Filtering Related Registers”)
3.3.2.2
R* — Reserved Bit
The reserved bit R* corresponds to the reserved bit in the header of the FlexRay frame. The controller
transmits that bit within the frame header. This bit must be cleared by the host for PS V1.9/V2.0 compliant
operation.
3.3.2.3
R — Reserved Bits
These bits are reserved for future use and have no correlation with the R* bit.
3.3.2.4
PP — Payload Preamble Bit
The payload preamble bit indicates that a static frame’s payload data hold a network management vector,
and that a dynamic frame’s payload data hold a message ID, respectively.
3.3.2.5
NFI — Null Frame Indication Bit
The null frame indication bit shows the value of the null frame indication flag for received frames stored
in message receive/FIFO buffers. This bit has no function for transmit message buffers. The NULLF bit,
described in Section 3.3.3, “Message Buffer Slot Status Vector”, indicates the reception of a null frame on
the physical layer.
NOTE
During the transition from the hard reset to the configuration state, the CC
initializes the NFI bits of all buffers to ‘0’. In the normal passive and active
states, the CC receives but does not store null frames. Therefore, after the
first reception and storage of a valid receive frame’s header and payload data
to a receive message/FIFO buffer, the CC sets the NFI bit of that buffer.
From that moment on, this bit remains set.
MFR4200 Data Sheet, Rev. 0
144
Freescale Semiconductor
Message Buffer
3.3.2.6
CYCLCNT[5:0] — Cycle Counter
The cycle counter field holds the CC cycle counter value at frame reception time. This field is not used in
message buffers configured for transmission.
3.3.2.7
LEN[6: 0] — Payload Length
The payload length field holds the number of words (1 word = 2 bytes) contained in the payload segment
of the frame.
Receive message buffers and receive FIFO:
The payload field indicates the value of the payload length field in the received frame (see Section 3.3.3,
“Message Buffer Slot Status Vector).
Transmit message buffers:
The payload field indicates the number of words to be transmitted.
If the host writes a payload length not equal to SPLR into a static frame, the CC generates the CHI error
interrupt SPLME (see Section 3.2.3.6.3, “CHI Error Register (CHIER)”).
If the host writes a payload length greater than MPLDR into a dynamic frame, the CC generates the CHI
error interrupt MDPLE (see Section 3.2.3.6.3, “CHI Error Register (CHIER)”).
Note that the size of the data field in the MFR4200 is limited to 32 bytes (see Section 3.1.1, “MFR4200
Features”).
3.3.2.8
HCRC[10:0] — Header CRC
The header CRC field contains a cyclic redundancy check code (CRC) computed over the sync bit, startup
bit, the frame ID, and the payload length fields of the frame.
Receive message buffers and Receive FIFO:
The header CRC field contains the header CRC of the semantically valid and syntactically correct received
frame.
Transmit message buffers:
The Header CRC field contains the Header CRC value calculated and provided by the host. Note that the
controller does not check if the Header CRC provided by the host is correct.
3.3.2.9
SYNC — Sync Bit
The SYNC bit determines whether the frame is to be used for clock synchronization.
Receive message buffers and Receive FIFO:
The bit contains the SYNC bit of the stored frame. This bit is updated only when a new semantically valid
frame matching the buffer filters has been stored in the message buffer.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
145
MFR4200 FlexRay Communication Controller
Transmit message buffers:
This bit is not used.
NOTE
The host sets up the slot ID determining the slot during which the CC
transmits a sync frame via the sync frame register SYNCFR (see
Section 3.2.3.3.29, “Sync Frame Register (SYNCFR)”).
3.3.2.10
STARTUP — Startup Bit
The STARTUP bit determines whether the frame is to be used for clock synchronization during startup.
Receive message buffers and Receive FIFO
The bit contains the STARTUP bit of the stored frame. This bit is updated only when a new semantically
valid frame matching the buffer filters has been stored in the message buffer.
Transmit message buffers
This bit is not used.
NOTE
The host sets up the STARTUP bit for transmit frames via the startup bit
SUP in register SYNCFR (see Section 3.2.3.3.29, “Sync Frame Register
(SYNCFR)”).
3.3.3
Message Buffer Slot Status Vector
All message buffers, including transmit buffers, comprise a message buffer slot status vector holding a
9-bit wide slot status information field.
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
CH
r
r
r
r
r
r
r
r
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
r
r
r
r
r
r
r
rh*
Figure 3-119. Transmit Message Buffer Slot Status Vector
MFR4200 Data Sheet, Rev. 0
146
Freescale Semiconductor
Message Buffer
15
14
13
12
11
10
9
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
CH
r
r
r
r
r
r
r
rh*
7
6
5
4
3
2
1
0
VCE
SYNCF
NULLF
SUPF
SERR
CERR
BVIOL
TXCON
rh*
rh*
rh*
rh*
rh*
rh*
rh*
r
Figure 3-120. Receive and Receive FIFO Message Buffer Slot Status Vector
•
•
•
•
•
•
•
3.3.3.1
NOTE
The CC indicates status information for transmit message buffers only,
in the TXCON bit; the remaining bits are used to indicated receive status
information. Therefore, if a message buffer is configured as a receive or
receive FIFO message buffer, its TXCON bit is not used by the CC. If a
message buffer is configured as a transmit message buffer, only its
TXCON bit is updated by the CC, while the remaining bits are not used
by the controller.
Refer to Table 3-4 for slot status monitoring availability in different
protocol states.
After reception of a null frame or an invalid frame, the controller updates
only the slot status vector of a selected receive message buffer or FIFO
buffer. Other fields (see Table 3-11 and Table 3-12) of those buffers stay
unaltered.
After reception of a valid frame, the controller updates the slot status
vector and the remainder of the receive message buffer or FIFO buffer.
After transmission of a frame, the controller updates the slot status
vector in the current transmit message buffer.
The controller updates a message buffer assigned to slot n within the first
macrotick of the slot n+1.
Empty static slots exhibit slot status 0x0000 on channel A and 0x0100
on channel B.
TXCON — TX Conflict
This flag indicates transmission conflicts, i.e. indicates that a reception is in progress when the controller
starts transmission. This bit indicates conflicts during transmission in static and dynamic segments.
0 – No transmission conflict detected.
1 – Transmission conflict detected.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
147
MFR4200 FlexRay Communication Controller
3.3.3.2
BVIOL — Boundary Violation
This flag provides information about media activity at slot boundaries (either the end or the beginning of
the current slot). Note that this is not necessarily an error condition, as a semantically valid frame can be
received between the slot boundaries, provided that the idle conditions before and after the frame are
fulfilled.
0 – No media activity detected at slot boundaries.
1 – Media activity detected at slot boundaries.
3.3.3.3
CERR — Content Error
This flag indicates the reception of a semantically incorrect frame.
0 – No content error occurred in current slot.
1 – Content error occurred in current slot.
3.3.3.4
SERR — Syntax Error
This flag indicates the reception of a syntactically incorrect frame.
0 – No syntax error occurred in current slot.
1 – Syntax error occurred in current slot.
3.3.3.5
SUPF — Startup Frame Indication
This flag indicates the reception of a frame header having its startup bit set.
0 – No syntactically correct startup frame received in current slot.
1 – Syntactically correct startup frame received in current slot.
3.3.3.6
NULLF — NULL Frame Indication
This flag indicates the reception of a frame header having its null frame indication bit set.
0 – No syntactically correct null frame received in current slot.
1 – Syntactically correct null frame received in current slot.
3.3.3.7
SYNCF — SYNC Frame Indication
This flag indicates the reception of a frame header having its sync frame indication set.
0 – No syntactically correct sync frame received in current slot.
1 – Syntactically correct sync frame received in current slot.
MFR4200 Data Sheet, Rev. 0
148
Freescale Semiconductor
Message Buffer
3.3.3.8
VCE — Valid Communication Element
This flag indicates the reception of a valid communication element. A valid communication element is
either a syntactically and semantically correct frame or symbol.
0 – No valid communication element received in current slot.
1 – Valid frame received in current slot.
3.3.3.9
CH — Channel
This flag indicates the channel the slot status refers to.
0 – Slot status of channel A.
1 – Slot status of channel B.
3.3.4
Message ID
If the payload preamble bit PP is set, the message ID field holds the message ID of a dynamic frame located
in the message buffer. The FIFO filter may use the received message ID for message ID filtering.
3.3.5
NMVector Fields
If the payload preamble bit PP is set, the network management vector fields hold the network management
vector of a static frame located in the message buffer.
3.3.6
Data[0:31] — Data Fields
Receive message buffers:
The data fields store received frame payload data, if all the receive filtering criteria are met.
Transmit message buffers:
The host writes these data fields with payload data to be transmitted.
Receive FIFO:
The data fields in the FIFO buffer stores a received frame’s payload data values if the channel, message
ID, and cycle counter are accepted by the configured receive FIFO acceptance filter value and mask, and
not rejected by the configured receive FIFO rejection filter value and mask, and if there is no matching
dedicated receive message buffer in the mailbox.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
149
MFR4200 FlexRay Communication Controller
3.4
Message Buffer Control, Configuration, Status and Filtering
Register Set
3.4.1
Message Buffer Control, Configuration and Status Register
Message buffer control, configuration and status register (BUFCSnR[0:58]). The BUFCS[0:58] layout is
the same for receive message buffers, transmit message buffers and FIFO. However, the access rules for
register bits depend on various modes of operation and on the buffer configuration.
Bit
Name
15
14
13
12
VALID
RO_NO/WR_CS
11
TT
CCFE
BT
DATUPD
NU
RO_NO/WR_CS
NU
RO_NO/WR_CS
10
9
8
ChB
ChA
BUFCMT
RO_NO/WR_CS
RO_NO/WR_CS
NU
Hard Reset
0
Access
rwh*
r
rw*
r
rwh*
rw*
rw*
r
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
WR
NU
NU
WR
RO
NU
RO_NO/WR_CS
0
0
rw
rh
Hard Reset
Access
r
rw
r
r
0
r
rw*
9
8
Figure 3-121. BUFCSnR of a Receive Message Buffer
Bit
15
14
Name
VALID
TT
RO
WR
13
12
11
10
CCFE
BT
DATUPD
ChB
ChA
BUFCMT
RO_NO/WR_CS
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
WR
Hard Reset
0
Access
rh
rw
rw*
rw*
r
rw*
rw*
rw
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
WR
NU
NU
WR
RO
NU
RO_NO/WR_CS
0
0
rw
rh
Hard Reset
Access
r
rw
r
r
0
r
rw*
Figure 3-122. BUFCSnR of a Transmit Message Single Buffer for the Dynamic Segment
MFR4200 Data Sheet, Rev. 0
150
Freescale Semiconductor
Message Buffer Control, Configuration, Status and Filtering Register Set
Bit
15
14
Name
VALID
TT
RO
RO_NO/WR_CS
13
12
11
CCFE
BT
DATUPD
RO_NO/WR_CS
RO_NO/WR_CS
NU
10
9
8
ChB
ChA
BUFCMT
RO_NO/WR_CS
RO_NO/WR_CS
WR
Hard Reset
0
Access
rh
rw*
rw*
rw*
r
rw*
rw*
rw
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
WR
NU
NU
WR
RO
NU
RO_NO/WR_CS
0
0
rw
rh
Hard Reset
Access
r
rw
r
r
0
r
rw*
Figure 3-123. BUFCSnR of a Host Part Transmit Message Buffer of a Double Tx Buffer for the Dynamic
Segment
Bit
15
14
Name
VALID
TT
RO
RO_NO/WR_CS
13
12
11
CCFE
BT
DATUPD
RO_NO/WR_CS
RO_NO/WR_CS
NU
10
9
8
ChB
ChA
BUFCMT
RO_NO/WR_CS
RO_NO/WR_CS
WR
Hard Reset
0
Access
rh
rw*
rw*
rw*
r
rw*
rw*
rw
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
WR
NU
NU
WR
RO
NU
RO_NO/WR_CS
0
0
rw
rh
Hard Reset
Access
r
rw
r
r
0
r
rw*
Figure 3-124. BUFCSnR of a Host Part Transmit Message Buffer of a Double Tx Buffer for the Static Segment
Bit
15
14
Name
VALID
TT
RO
RO_NO/WR_CS
13
12
11
CCFE
BT
DATUPD
RO_NO/WR_CS
RO_NO/WR_CS
NU
10
9
8
ChB
ChA
BUFCMT
RO_NO/WR_CS
RO_NO/WR_CS
WR
Hard Reset
0
Access
rh
rw*
rw*
rw*
r
rw*
rw*
rw
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
WR
NU
NU
WR
RO
NU
RO_NO/WR_CS
0
0
rw
rh
Hard Reset
Access
r
rw
r
r
0
r
rw*
Figure 3-125. BUFCSnR of a Single Transmit Message Buffer for the Static Segment
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
151
MFR4200 FlexRay Communication Controller
Bit
15
14
13
12
11
10
9
8
Name
VALID
TT
CCFE
BT
DATUPD
ChB
ChA
BUFCMT
RO
RO
RO
RO
NU
RO
RO
RO
Hard Reset
0
Access
rh
r
r
r
r
r
r
r
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
NU
NU
NU
RO
RO
NU
RO
0
0
r
rh
Hard Reset
Access
r
r
r
r
0
r
r
Figure 3-126. BUFCSnR of a CC Part Transmit Message Buffer of a Double Tx Buffer for Dynamic and Static
Segment
Bit
15
14
13
12
11
10
9
8
Name
VALID
TT
CCFE
BT
DATUPD
ChB
ChA
BUFCMT
NU
NU
NU
NU
NU
NU
NU
NU
Hard Reset
0
Access
r
r
r
r
r
r
r
r
Bit
7
6
5
4
3
2
1
0
Name
Reserved
LOCK
Reserved
Reserved
IENA
IFLG
Reserved
CFG
NU
WR
NU
NU
NU
NU
NU
NU
0
0
r
r
Hard Reset
Access
r
rwh
r
r
0
r
r
Figure 3-127. BUFCSnR of FIFO Buffer
Where:
RO_NO/WR_CS
3.4.1.1
Host read/write access during the configuration state, in other states – Host read access;
RO
Host read-only access
WR
Host read/write access
NU
Reserved or not used
CFG — Message Buffer Configuration Bit
This bit is used to configure the corresponding buffer as a transmit or receive message buffer. CFG bit is
cleared by a hard reset. The access to this bit is defined in Table 3-16.
1 – The corresponding buffer is configured as a transmit message buffer.
0 – The corresponding buffer is configured as a receive message buffer.
MFR4200 Data Sheet, Rev. 0
152
Freescale Semiconductor
Message Buffer Control, Configuration, Status and Filtering Register Set
3.4.1.2
IFLG — Interrupt Status Flag
The IFLG flag is provided by the CC. It performs different functions depending on the configuration of the
corresponding message buffer.
Receive message buffer:
The flag indicates that the controller has updated the receive message buffer due to frame reception (update
of data fields and the slot status vector after reception of a valid frame, or update of the slot status vector
after reception of an invalid frame). The host can clear the flag by a buffer lock operation.
1 – The controller sets the flag when the receive message buffer was updated after a frame reception. The
host must process received data and clear the IFLG bit.
0 – The message buffer is not updated, or the host has cleared the IFLG bit implicitly by locking the
message buffer.
Transmit message buffer:
The flag indicates that the message buffer is empty, or that the controller has transmitted a frame from that
message buffer. The host can clear the flag by a buffer lock operation.
1 – The flag is set by the controller when the transmit message buffer is empty/not updated (i.e. has been
transmitted). The host may write new data to the buffer.
0 – The flag is cleared implicitly by the host when the transmit message buffer is updated (i.e. locked).
Receive FIFO buffer:
The flag has no meaning; it will never be set.
NOTE
1. The IFLG bit is set to the value of the CFG bit with each write to a BUFCSnR register, during the
configuration state. During normal operation, the controller updates the IFLG bit after frame
transmission (transmit message buffer) and after frame reception (receive message buffer).
— If CFG is clear (receive message buffer) the CC clears the IFLG bit, also, indicating that the
receive message buffer does not hold new receive data.
— If CFG is set (transmit message buffer) the CC sets the IFLG bit, also, indicating that the
transmit message buffer is empty and will be filled by the host application.
2. If the host does not write to a BUFCSnR register during the configuration state, the IFLG holds
the value it had before it entered the configuration state.
3.4.1.3
IENA — IFLG Interrupt Enable
This bit enables the corresponding message buffer as an IFLG bit interrupt source. If the message buffer
is configured as a receive message buffer, the generated by the CC interrupt is a read interrupt. If the
message buffer is configured as a transmit message buffer, the interrupt generated by the CC is a write
interrupt.
1 – The corresponding message buffer interrupt is enabled.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
153
MFR4200 FlexRay Communication Controller
0 – The corresponding message buffer interrupt is disabled.
This bit is not used for the FIFO.
3.4.1.4
LOCK — Message Buffer Lock Request
The bit has various functions depending on the configuration of the corresponding message buffer.
The host can implicitly lock/unlock the buffer by writing ‘1’ to the LOCK bit. Writing a ‘1’ to the LOCK
bit toggles the value of the LOCK bit:
• A buffer is locked when the LOCK bit read operation returns ‘1’.
• A buffer is unlocked when the LOCK bit read operation returns ‘0’.
Receive FIFO:
The host must lock a FIFO buffer to make it accessible in the active receive FIFO buffer window. The host
can request a FIFO buffer lock by writing a ‘1’ to the LOCK bit of buffer 0, provided the FIFO is
configured. Writing a ‘0’ to the LOCK bit has no effect on the bit. An attempt to lock the FIFO through,
not buffer 0, but another FIFO buffer’s LOCK bit, causes a FIFO buffer lock error (see Section 3.2.3.6.3,
“CHI Error Register (CHIER)”).
Receive message buffer:
The host must lock a receive message buffer in order to make it accessible in the active receive message
buffer window. The host can request a message buffer lock by writing a’1’ to the LOCK bit. Writing a ‘0’
to the LOCK bit has no effect on the bit. When the buffer is locked, the LOCK bit read operation returns
‘1’.
Transmit message buffer:
The host must lock the buffer in order to make it accessible through the active transmit message buffer
window. The host can request a buffer lock by writing a ‘1’ to the LOCK bit. Writing a ‘0’ to the LOCK
bit has no effect on this bit. When the buffer is locked, the LOCK bit read operation returns ‘1’. A buffer
committed for transmission (appropriate BUFCMT bit is ‘1’) cannot be locked. If the host sends a lock
request for the committed transmit message buffer, a lock error will be raised (see Section 3.2.3.6.3, “CHI
Error Register (CHIER)”).
•
•
NOTE
For more information about the locking/unlocking procedure, see
Section 3.5.3.4, “Active Buffers Locking/Unlocking and Locking
Timing”.
Writing to the LOCK bit causes all other bits of a message buffer control
and status register to be ignored for this write access to the buffer control
register, i.e. it is not possible to update the buffer control register with
the same write operation as toggles the locked/unlocked status of the
buffer. The lock/unlock request is not stored — there is no pending lock
request.
MFR4200 Data Sheet, Rev. 0
154
Freescale Semiconductor
Message Buffer Control, Configuration, Status and Filtering Register Set
•
•
3.4.1.5
Unlocking the buffer in the FIFO moves the FIFO buffer access pointer
to the next buffer in the FIFO (see Section 3.6, “Receive FIFO
Function”). So, the FIFO does not support multiple consecutive
locking/unlocking of the same FIFO entry.
The host locks the FIFO buffers by setting the LOCK bit in FIFO buffer
number 0.
BUFCMT — Message Buffer Commit Flag
The host commits a transmit message buffer for transmission by setting the BUFCMT flag of the
corresponding buffer to ‘1’.
The CC checks the BUFCMT bit of all transmit message buffers when it schedules a transmission.
The CC can transmit, or put a frame from a transmit message buffer into a transmission schedule, only
when the buffer is committed for transmission (BUFCMT = 1), unlocked (LOCK = 0), and all internal
procedures on that transmit message buffer are finished (copying process, unlock process, a transmission).
At the end of buffer transmission, The CC clears the BUFCMT bits of single transmit message buffers and
CC part buffers of double transmit message buffers committed for transmission.
The CC clears the BUFCMT bit of a double buffer’s host part at the end of the buffer copy process. During
the buffer copy process, the CC copies buffer data from the buffer’s CC part to the buffer’s host part.
The host may set the BUFCMT bit only for a locked transmit message buffer. To complete the commit
operation, the host must unlock the buffer. Thereafter, the CC indicates a successful commitment with the
BUFCMT set. The read operation of a BUFCMT bit always returns a ‘0’ for a locked buffer.
1 – The transmit message buffer is committed for transmission.
0 – The transmit message buffer is not committed for transmission.
NOTE
This flag is related only to transmit message buffers. Reading or writing to
BUFCMT bit in a receive message buffer has no meaning (i.e., this bit is not
used). When the host writes ‘1’ to the BUFCMT bit, that value will be stored
until the CC clears it; so, only one write is necessary. Writing a ‘0’ to the
BUFCMT location does not change its state.
3.4.1.6
ChA, ChB — Channel A and Channel B Flags
ChA and ChB are channel filtering bits associated with each buffer. They serve as a filter for a receive
message buffer, and as a control field for a transmit message buffer.
Receive message buffer:
Received frames are stored if they are received on all the specified channels in the channel filtering field.
Other filtering criteria must also be met.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
155
MFR4200 FlexRay Communication Controller
Transmit message buffer:
The content of the buffer is transmitted only on the channels specified in the channel filtering field when
the cycle counter filtering and frame ID filtering criteria are also met.
Receive FIFO:
Those bits have no meaning for the receive FIFO (refer to Section 3.6, “Receive FIFO Function” for more
information about FIFO filters)
Table 3-15. Channel Filtering Configuration
ChA
ChB
Transmit message buffer
Transmit frame
Receive message buffer
Store semantically valid received frame
1
1
on both channels
ignore frame
1
0
on channel A
received on channel A
0
1
on channel B
received on channel B
0
0
no transmission
ignore frame
3.4.1.7
CCFE — Cycle Counter Filtering Enable Bit
The host controls the cycle counter filtering (refer to Section 3.2.3.8.4, “Cycle Counter Filter n Register,
n = [0:58] (CCFnR)”) of a buffer by the cycle counter filtering enable bit.
1 – Cycle counter filtering is enabled.
0 – Cycle counter filtering is not performed.
3.4.1.8
DATUPD — Data Updated
DATUPD indicates if the frame data was or was not updated during the last matching slot/cycle/channel
triple in the static segment according to the filter. The CC updates the DATUPD bit after every static slot
assigned to this buffer. The host may reset this bit during the configuration state by writing a “0” to the bit.
Note that DATUPD is not reset by empty minislots in the dynamic segment. It is set, however, when a
semantically valid frame is received in the dynamic segment.
1 – A semantically valid (non null) frame was received during the last slot with a matching
slot/cycle/channel triple.
0 – Either a frame that was not semantically valid or a null frame was received during the last slot with a
matching slot/cycle/channel triple.
3.4.1.9
BT — Buffer Type
The host can configure every buffer of the CC as a single transmit message buffer or as a double message
buffer. The handling and the operations for buffers with different types are specified in Section 3.5,
“Message Buffer Handling and Operations”.
0 – Single transmit message buffer.
MFR4200 Data Sheet, Rev. 0
156
Freescale Semiconductor
Message Buffer Control, Configuration, Status and Filtering Register Set
1 – Double transmit message buffer.
3.4.1.10
TT — Type of Transmission
The host can configure the type of transmission used for a buffer. Therefore, the CC can combine two types
of systems — event and state driven systems.
0 – Event type of transmission
1 – State type of transmission
NOTE
The TT bit controls how the CC operates with the VALID bit.
3.4.1.11
VALID — Message Buffer Valid Flag
The semantic of this status bit depends on the configuration of the message buffer.
Transmit message buffer:
The valid bit indicates whether a transmit buffer holds valid for transmission data or not.
The CC clears the VALID bit of a transmit message buffer when the host locks it.
When the host has committed the buffer for transmission (see the BUFCMT bit description in
Section 3.4.1, “Message Buffer Control, Configuration and Status Register”) and unlocked it, the
controller performs the following operations:
• Sets the appropriate VALID bit — valid data frame.
• Clears the VALID bit when the frame has been transmitted, if the appropriate TT bit of the buffer
is clear (event type of transmission).
• Does not change the VALID bit when the frame has been transmitted, if the appropriate TT bit of
the buffer is set (state type of transmission).
1 – The corresponding buffer contains a semantically valid frame to be transmitted.
0 – The corresponding buffer does not contain a semantically valid frame to be transmitted.
Receive message buffer
The VALID bit indicates whether a receive message buffer holds semantically valid frame data or not.
It is up to the host to reset this bit during the configuration state. It changes to ‘1’ when the first valid non
null frame is received.
1 – The corresponding buffer contains semantically valid frame data.
0 – The corresponding buffer does not contain semantically valid frame data.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
157
MFR4200 FlexRay Communication Controller
NOTE
The host can write the VALID bit only during the configuration state, for
receive message buffers. During all other modes of the CC this bit is
read-only.
3.4.1.12
Reserved — Reserved
Those bits are reserved for future use. Reserved bit are accessible by host read operations only. They have
an undefined state.
3.4.2
Message Buffer Filter Registers
The cycle counter filter register CCFnR[0:58] is shown in the following figures.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
Reserved
Cycle Count Mask
Reserved
Cycle Count Value
NU
RO_NO/WR_CS
NU
RO_NO/WR_CS
1
0
1
0
Figure 3-128. CCFnR, Transmit and Receive Message Buffer Filter Registers
15
14
13
12
11
10
9
8
7
6
5
4
3
2
Reserved
Cycle Count Mask
Reserved
Cycle Count Value
NU
RO
NU
RO
Figure 3-129. CCFnR, CC Part Buffer of a Double Transmit Message Buffer Filter Registers
15
14
13
12
11
10
9
8
7
6
5
4
3
2
Reserved
Cycle Count Mask
Reserved
Cycle Count Value
NU
NU
NU
NU
1
0
Figure 3-130. CCFnR, FIFO Buffer Filter Registers
Where:
RO_NO/WR_CS
Field with host read-only access during normal operation (host write access in configuration state only)
RO
Field with host read-only access
NU
Reserved or not used
Message buffer filter registers sets are used only for transmit and receive message buffers, not for the FIFO.
The FIFO has its own filter register set (see Section 3.2.3.8, “Filtering Related Registers”).
3.4.2.1
Cycle Counter Filter Register (CCFnR)
The operation of the filtering mechanism depends on the configuration of the buffer.
Receive message buffer:
The received frame is stored only if all the following conditions are met.
MFR4200 Data Sheet, Rev. 0
158
Freescale Semiconductor
Message Buffer Control, Configuration, Status and Filtering Register Set
•
•
•
The received cycle counter matches an element of the buffer’s cycle filter register, if cycle filtering
is enabled;
Channel and frame ID criteria are met;
The received message has passed all error checks (see the PWD: Message Error Check chapter)
Transmit message buffer:
The content of the buffer is transmitted, when an element of the cycle filter register matches the current
cycle counter, and the frame ID matches the slot counter value.
For a detailed description of the CCFR registers, see Section 3.2.3.8.4, “Cycle Counter Filter n Register,
n = [0:58] (CCFnR)”.
3.4.3
Receive FIFO Filters
There are two filter sets available for FIFO filtering:
• One FIFO acceptance filter set, comprising the following registers:
— FIFO acceptance filter message ID value register
(see Section 3.2.3.8.5, “FIFO Acceptance Filter Message ID Value Register (FAFMIDVR)”)
— FIFO acceptance filter message ID mask register
(see Section 3.2.3.8.6, “FIFO Acceptance Filter Message ID Mask Register (FAFMIDMR)”)
• One FIFO rejection filter set, comprising the following registers:
— FIFO rejection filter frame ID value register
(see Section 3.2.3.8.8, “FIFO Rejection Filter Frame ID Value Register (FRFFIDVR)”)
— FIFO rejection filter frame ID mask register
(see Section 3.2.3.8.9, “FIFO Rejection Filter Frame ID Mask Register (FRFFIDMR)”)
The channels, from which the received frame will be accepted or rejected by the FIFO acceptance/rejection
filters, are specified by the FAFCHR register (see Section 3.2.3.8.7, “FIFO Acceptance/Rejection Filter
Channel Register (FAFCHR)”).
NOTE
The information from a received frame will be stored in the FIFO provided
the following conditions are met:
•
•
•
The receive message buffer filtering did not succeed, i.e. none of the
configured receive message buffers has a matching filter.
The message ID is accepted by the configured acceptance filter set.
The frame ID is not rejected by the configured rejection filter set.
NOTE
Frame ID filtering and message ID filtering can be enabled/disabled
independently of each other by setting the masks and values appropriately:
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
159
MFR4200 FlexRay Communication Controller
•
•
3.5
3.5.1
To disable frame ID filtering, set the frame ID value to 0x0000 and the
frame ID mask to 0xFFFF. (No semantically valid frame ID will be
rejected.)
To disable message ID filtering, set the message ID mask to 0x0000 (all
message IDs are accepted).
Message Buffer Handling and Operations
Introduction
The FlexRay MFR4200 uses a partial double buffering technique to provide a scheme for buffer handling.
Using this technology, buffers can be configured as single/double transmit message buffers, or partially, as
single and as double transmit message buffers, as required by the application. At the same time, the
FlexRay MFR4200 offers enhanced:
• Active window mechanism
• Interrupt service
• Buffer access scheme
The new buffer handling and operations scheme has the following features.
• The host and the CC have independent access to all the buffers. Therefore, the host can access
receive/transmit message buffers almost instantly while the CC transmits/receives frames.
• The host can configure receive/transmit buffers in the configuration state and partially, during
normal operation (see Section 3.5.5, “Buffer Reconfiguration in the Normal State of Operation”).
• The buffer configuration map is flexible.
• The buffer mechanism supports multiple locking/unlocking of the same transmit buffer, without
committing for transmission.
• The host can commit a transmit message buffer for transmission without update or with only partial
update of its data fields.
• The host explicitly controls every transmit buffer commitment for transmission.
• The host can access a receive message buffer while the CC receives a new frame for that buffer.
All features are described in more detail in the following sections.
3.5.2
Buffer Map
The FlexRay CC memory map including buffers locations is shown in Table 3-1.
The host accesses CC internal buffer data, configuration, and status fields only through appropriate active
receive/ transmit/FIFO message buffers by using the locking mechanism. Shadow receive message buffers
serve the host accesses to message buffers while the CC continues to receive/transmit frames.
MFR4200 Data Sheet, Rev. 0
160
Freescale Semiconductor
Message Buffer Handling and Operations
3.5.3
Active Message Buffers
The concept of active message buffers simplifies buffer access for the host. If a buffer is locked by the host,
then, depending on the message buffer configuration, the buffer data and configuration information is
mirrored to one of the active buffers — the active receive message buffer, the active transmit message
buffer, or the active receive FIFO buffer.
3.5.3.1
Active Receive Message Buffer
The active receive message buffer (see Table 3-1) contains receive message buffer data and configuration
fields. Any receive message buffer is accessible through the active receive message buffer after the locking
procedure for this buffer has been finished. The active receive message buffer layout is shown in
Table 3-11.
Buffer control, configuration, filtering and status data is stored in the buffer control, configuration, status
and filtering registers set. The layout of the set is presented in Figure 3-131.
Message Buffer Control, Configuration and Status
Register (BUFCS0R)
Cycle Counter Filter 0 Register (CCF0R)
Message Buffer 0
Buffer Control,
Configuration, Status and
Filtering Registers Set
...
472 Bytes
(4 Words X 59 Buffers)
...
...
Message Buffer Control, Configuration and Status
Register (BUFCS58R)
Cycle Counter Filter 0 Register (CCF58R)
Message Buffer 58
Figure 3-131. Buffer Control, Configuration, Status/Filtering Register Set for Transmit/Receive Buffers
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
161
MFR4200 FlexRay Communication Controller
NOTE
Figure 3-131 does not apply to message buffers configured as receive FIFO
buffers.
3.5.3.2
Active Transmit Message Buffer
The active transmit message buffer (see Table 3-1) contains transmit message buffer data and configuration
fields. Any transmit message buffer is accessible through the active transmit message buffer after the buffer
has been locked successfully. The active transmit message buffer layout is shown in Table 3-13.
Buffer control, configuration, filtering and status data is stored in the buffer control, configuration, status
and filtering registers set. The layout of the set is presented in Figure 3-131.
3.5.3.3
Active Receive FIFO Buffer
The active receive FIFO message buffer (see Table 3-1) contains receive FIFO buffer data and
configuration fields. Any receive FIFO buffer is accessible through the active receive FIFO buffer after the
locking procedure for this buffer has been finished.
For a detailed description of FIFO access, refer to Section 3.6, “Receive FIFO Function”. The active
receive FIFO buffer layout is shown in Table 3-12. The locking procedure for receive FIFO buffers is
different from the receive/transmit message buffer locking operation (see Section 3.5.3.4, “Active Buffers
Locking/Unlocking and Locking Timing” and the LOCK bit description in Section 3.2.3.7.2, “Message
Buffer Control, Configuration and Status n Register, n = [0:58] (BUFCSnR)”).
NOTE
Figure 3-131 is applicable for transmit and receive message buffers only, not
for receive FIFO buffers.
If a buffer is configured as a receive FIFO buffer, only its buffer control, configuration and status register
(BUFCSnR) is used; the CCFnR registers are not. Instead of the CCFnR registers, the FIFO acceptance
filter registers and FIFO rejection filter registers must be used.
The buffer control, configuration, status and filtering register set for the receive FIFO buffers is shown on
the Figure 3-132. Buffer 0 is configured as a receive FIFO buffer.
MFR4200 Data Sheet, Rev. 0
162
Freescale Semiconductor
Message Buffer Handling and Operations
Message Buffer Control, Configuration and Status
Register (BUFCS0R)
Not used
Message Buffer 0 — Configured as a Receive FIFO Buffer
Buffer Control,
Configuration, Status and
Filtering Registers Set
...
472 Bytes
(4 Words X 59 Buffers)
...
...
Message Buffer Control, Configuration and Status
Register (BUFCS58R)
Cycle Counter Filter 0 Register (CCF58R)
Message Buffer 58
Figure 3-132. Buffer Control, Configuration, Status/Filtering Register Set for Receive FIFO Buffers
Buffer 0 is configured as a receive FIFO buffer; the remaining buffers are configured as receive or transmit
message buffers.
3.5.3.4
Active Buffers Locking/Unlocking and Locking Timing
The host accesses any buffer through the active buffers by using the locking/unlocking mechanism.
The LOCK bit serves as locking request (control data) and acknowledgement (status data) at the same time
(hence, the host write and read operations to that bit return different values). For a detailed description of
the LOCK bit, refer to Section 3.4, “Message Buffer Control, Configuration, Status and Filtering Register
Set”.
Locking/unlocking procedure:
1. The host sends a message buffer lock request by writing ‘1’ to the appropriate LOCK bit of the
message buffer in the BUFCSnR register (see Section 3.4.1, “Message Buffer Control,
Configuration and Status Register”).
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
163
MFR4200 FlexRay Communication Controller
2. The host checks that the message buffer is locked (accessible through an active buffer) by reading
the LOCK bit. If the resulting value is ‘1’, the message buffer was locked successfully. Otherwise,
the message buffer could not be locked and the lock request must be repeated.
3. At the same time, the host checks for a locking error by reading the lock interrupt flag CHIERRIF
in the interrupt status register ISR0 (see Section 3.2.3.6.6, “Interrupt Status Register 0 (ISR0)”).
4. In the event of a locking error, the host may determine the cause of the error (see
Section 3.2.3.6.3, “CHI Error Register (CHIER)”), and may retry, if necessary.
5. Depending on the message buffer type, the host performs buffer read or read/write operations
when the message buffer becomes available through an active buffer (LOCK = ‘1’). All transmit
message buffers are accessible through the active transmit message buffer, receive message
buffers through the active receive message buffer, and FIFO buffers through the active receive
FIFO buffer. Once the message buffer is locked, the host accesses it without checking the LOCK
bit.
6. When the host has finished the message buffer update, it can unlock the message buffer by writing
again ‘1’ to the LOCK bit. This request to unlock the message buffer is always and immediately
granted, so the host does not have to check the state of the LOCK bit.
7. The host can start a locking procedure for another message buffer.
Locking principles:
•
•
•
•
•
•
•
•
•
•
•
•
The host accesses the FIFO, receive message buffers, and transmit message buffers only through
the active receive FIFO buffer, the active receive message buffer, and the active transmit message
buffer.
The host must lock a buffer, to make it accessible through an active message buffer.
The host must unlock a message buffer when it has finished accessing it.
The host cannot access shadow message buffers.
The host cannot lock more than one receive message buffer and not more than one transmit
message buffer.
The host can lock up to three buffers mirrored to the appropriate active buffers at the same time —
one transmit message buffer, one receive message buffer, and one receive FIFO buffer.
The host may lock and unlock transmit and receive message buffers several times before
committing them.
The host may commit a transmit message buffer for transmission (by setting BUFCMT to ‘1’) after
performing several locking/unlocking procedures on that buffer before committing.
Unlocking the buffer in the FIFO will move the FIFO buffer access pointer to the next buffer in the
FIFO. Therefore, the FIFO does not support multiple consecutive locking/unlocking procedures for
one FIFO buffer.
The host cannot lock CC part buffers of double transmit message buffers.
The host can lock only the host part buffers of double transmit message buffers.
Once the buffer is locked, the host accesses it without checking the LOCK bit.
MFR4200 Data Sheet, Rev. 0
164
Freescale Semiconductor
Message Buffer Handling and Operations
Locking errors:
Refer to Section 3.2.3.6.3, “CHI Error Register (CHIER)” for a detailed description. The most important
points are as follows.
• If the controller receives two frames for a receive message buffer that is locked by the host, the
controller discards the older frame and sets the frame lost error FLE in the CHIER register.
• A message buffer committed for transmission (its BUFCMT bit is ‘1’) cannot be locked. If the host
sends a lock request for the committed transmit message buffer, a lock error is raised.
• The host cannot access the odd buffers (CC part buffers) of the double transmit message buffers. If
it sends a locking request for any odd buffer of a double transmit message buffer, a lock error is
raised.
• If the host tries to lock a second transmit or receive buffer or a second FIFO buffer, the controller
issues a lock error. See the description of the RBLE, TBLE, FBLE bits in Section 3.2.3.6.3, “CHI
Error Register (CHIER)”.
NOTE
The host can write the BUFCMT bit of a message buffer only after the buffer
is locked and available through an active buffer. The BUFCMT bit is part of
the message buffer control, configuration, and status registers
BUFCSnR[0:58] (see Section 3.4.1, “Message Buffer Control,
Configuration and Status Register”).
Locking timing:
If a transmit message buffer (single or double) was committed for transmission in slot n and unlocked by
the host, and if the CC has scheduled this buffer for transmission in slot n, then this buffer is locked by the
CC for transmission (see the BB bit description in Section 3.2.3.6.3, “CHI Error Register (CHIER)”) for
the time shown in Figure 3-133.
TX Buffer Locking (Slot ID = n)
4 µT
communication cycle
4 µT
slot n-1
locking possible
1
slot n
locking impossible1
NIT
locking possible
If the host issues a lock request here, the CC does not grant the lock request, but sets the BB flag
in the CHIER register indicating a transmit message buffer busy lock error.
Figure 3-133. Buffer Busy Bit Timing for a Transmit Message Buffer
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
165
MFR4200 FlexRay Communication Controller
3.5.4
Buffer Configuration
For the CC to start up correctly, the host must configure all the used buffers during the configuration state.
The host can reconfigure buffers partially during normal operation (see Section 3.5.5, “Buffer
Reconfiguration in the Normal State of Operation”). An example of buffer configuration is presented in
Figure 3-134.
Each buffer is one of following:
• Receive FIFO buffer
• Receive message buffer
• Single transmit message buffer
• Double transmit message buffer
Each double transmit message buffer consists of two parts — the host part buffer and the CC part buffer.
The host part buffer of a double transmit message buffer is a buffer with an even number configured as a
double transmit message buffer.
The CC part buffer of a double transmit message buffer is a buffer with the next (after the host part buffer)
number.
The accessibility of buffer fields depends on the buffer configuration. All information about buffer field
accessibility is summarized in Table 3-16.
MFR4200 Data Sheet, Rev. 0
166
Freescale Semiconductor
Message Buffer Handling and Operations
Table 3-16. CC Buffer Fields Accessibility
Receive Message
Buffer
Receive FIFO
Buffer
Single Transmit
Message Buffer
for Static
Segment
Single Transmit
Message Buffer
for Dynamic
Segment
Host Part Buffer
of a Double
Transmit
Message Buffer
R*
RO
RO
RO_NO/WR_CS
WR
RO_NO/WR_CS
PP
RO
RO
RO_NO/WR_CS
WR
RO_NO/WR_CS
NFI
RO
RO
NU
NU
NU
SYNC
RO
RO
NU
NU
NU
STARTUP
RO
RO
NU
NU
NU
FRAME ID
RO_NO/WR_CS
RO
RO_NO/WR_CS
WR
RO_NO/WR_CS
Cycle Counter
RO
RO
NU
NU
NU
Payload Length
RO
RO
RO_NO/WR_CS
WR
RO_NO/WR_CS
Header CRC
RO
RO
RO_NO/WR_CS
WR
RO_NO/WR_CS
DATA
RO
RO
WR
WR
WR
Message Buffer Slot
Status Vector
RO
RO
RO
RO
RO
CFG
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
IFLG
RO
NU
RO
RO
RO
IENA
WR
NU
WR
WR
WR
LOCK
WR
WR
WR
WR
WR
BUFCMT
NU
NU
WR
WR
WR
ChA
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
ChB
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
DATUPD
RO_NO/WR_CS
NU
NU
NU
NU
NU
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
NU
NU
RO_NO/WR_CS
WR
RO_NO/WR_CS
VALID
RO_NO/WR_CS
NU
RO
RO
RO
Cycle Counter mask
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
Cycle Counter Value
RO_NO/WR_CS
NU
RO_NO/WR_CS
RO_NO/WR_CS
RO_NO/WR_CS
Field
Buffer
BT
CCFE
TT
Where
RO_NO/WR_CS
Field with host read-only access during normal operation. Host write access only in configuration state
RO
Field with host read-only access
WR
Field with host read/write access
NU
Not used (always hold fixed value – ‘0’). Fields with host read access only
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
167
MFR4200 FlexRay Communication Controller
Configuration Procedure during Configuration State
1. The CC enters the configuration mode after a hard reset or by the CONFIG bit in the MCR0 register
being set (see Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”). After a hard reset,
all message buffers are initialized to as receive message buffers disabled for receive operations
(frame ID=0x0). All the bits in the BUFCSnR registers are initialized to 0; the frame ID fields and
CCFnR are cleared (to 0).
2. After the CC has entered the configuration state, the host configures a message buffer:
— The host configures the BUFCSnR register (CFG, IENA, CHA, CHB, BT, CCFE, and TT bits)
(see Section 3.4.1, “Message Buffer Control, Configuration and Status Register”).
— The host configures the CCFnR register of the message buffer.
— The host locks a message buffer in accordance with Section 3.5.3.4, “Active Buffers
Locking/Unlocking and Locking Timing”.
— After the message buffer is locked, the host configures the remaining configuration fields of the
message buffer in accordance with the configuration principles (see below).
— The host unlocks the message buffer.
3. After the host has configured the message buffers, it requests the CC to leave the configuration
state by setting the CONFIG bit in the MCR0 register to ‘0’. Configuration becomes active after
the CC leaves the configuration state.
4. After the CC leaves the configuration state, it goes to the normal mode of operation (see
Section 3.9, “Communication Controller States”).
NOTE
After leaving the hard reset state (the hard reset signal is negated), on the
next rising edge of the CC_CLK signal, the CC starts performing an internal
initialization procedure (see Section 3.9.1, “Hard Reset State” and
Section 3.2.3.1.3, “Magic Number Register (MNR)”).
During this internal initialization procedure, the CC initializes its internal memory, including the following
message buffer configuration/control parameters.
• Frame ID = 0x0
• CCFnR: Cycle Count Mask and Cycle Counter Value fields = ‘0’s
• BUFCSnR:
— BUFCMT = 0
— ChA,ChB = 0
— BT= 0
— CCFE = 0
— TT = 0
— LOCK = 0
— IFLG = 0
— VALID = 0
— IENA = 0
MFR4200 Data Sheet, Rev. 0
168
Freescale Semiconductor
Message Buffer Handling and Operations
— CFG = 0
— DATUPD = 0
During the internal initialization procedure, the host must not access any CC registers except MNR (see
Section 3.2.3.1.3, “Magic Number Register (MNR)”), which acknowledges the finish of the internal
initialization procedure.
Message Buffer Configuration Principles
•
•
•
•
•
•
•
•
•
•
After a hard reset, all message buffers are initialized as receive message buffers disabled for receive
operations (frame ID=0x0). In normal operation, any buffers not configured by the host, during the
configuration state, remain receive message buffers disabled for receive operations.
If a configuration includes FIFO buffers (see Section 3.2.3.7.1, “FIFO Size Register (FSIZR)”), the
FIFO starts from message buffer 0 (see Figure 3-134).
Buffers of different types can be mixed in the buffer map (receive, single transmit, double transmit,
and transmit/receive message buffers that are not used for transmit/receive operations (frame
ID=0x0)) (see Figure 3-134).
FIFO buffers:
— must be placed in a continuous subset of message buffers that is uninterrupted by buffers of
other types
— the number of message buffers reserved for the FIFO is determined by the FIFO size register
value (see Section 3.2.3.7.1, “FIFO Size Register (FSIZR)”)
The host part buffer of a double transmit message buffer must have an odd number.
The number of the CC part buffer of a double transmit message buffer must be its host part buffer
+ 1.
During the configuration state, only the host part buffer of a double transmit message buffer is
available for host read/write configuration operations. Hence, the host part buffer configuration is
used for both parts of a double transmit message buffer. The configuration of the host part buffer
overwrites the configuration of the CC part buffer.
Only transmit message buffers can be configured as double transmit message buffers.
FIFO and receive message buffers are always single buffers.
CC part buffers of double transmit message buffers have read-only host access. CC part buffers
cannot be locked; consequently, the host can read only the BUFCSnR and CCFnR registers of the
buffer.
An example of buffer configuration is presented in Figure 3-134.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
169
MFR4200 FlexRay Communication Controller
Buffer 0
Host cannot reconfigure
the FIFO size during
Normal mode of
operation
Buffer 1
Buffer 2
Buffer 3
Buffer 4
Host can reconfigure
those buffers during
Normal mode of
operation
Buffer 5
Buffer 6
Buffer 7
Buffer 8
Buffer 9
Buffer 10
Buffer 11
Buffer 12
Buffer 13
Buffer 14
Buffer 15
Buffer 16
Buffer 17
Buffer 18
Buffer 19
Buffer 52
Buffer 53
Buffer 54
Buffer 55
Buffer 56
Buffer 57
…
...
Buffer 58
Buffer
- Receive FIFO Buffer
Buffer
- Receive Message Buffer
Buffer
- Transmit Message Buffer (Dynamic segment)
Buffer
- Transmit Message Buffer (Static segment)
- Single Buffer
Buffer
Buffer
Buffer
- Double Buffer
Figure 3-134. Example of a Buffer Configuration
3.5.4.1
Receive Message Buffer Configuration
Receive message buffers can be configured in the configuration state. The configuration must be done in
accordance with the configuration procedure and principles. The CFG bits in the BUFCSnR of receive
message buffers are 0.
The number of receive message buffers is configurable; however, receive message buffers cannot be placed
between FIFO buffers or between the host and CC parts of double transmit message buffers. Receive
message buffers cannot be double message buffers.
MFR4200 Data Sheet, Rev. 0
170
Freescale Semiconductor
Message Buffer Handling and Operations
It is possible to configure from 0 to 59 buffers as receive message buffers.
3.5.4.2
Transmit Message Buffer Configuration
Transmit message buffers can be configured in the configuration state. Single transmit message buffers for
the dynamic segment can be configured in the configuration state and during normal operation. The
configuration must be done in accordance with the configuration procedure and principles. The CFG bits
in the BUFCSnR of transmit message buffers are 1’s.
The number of transmit message buffers is configurable; however, transmit message buffers cannot be
placed between FIFO buffers or between the host and CC parts of double transmit message buffers.
Transmit message buffers can be configured as single or double transmit message buffers for static and
dynamic segments.
If a message buffer is part of a double transmit message buffer:
• The host part buffer must be an even number buffer only.
• The CC part buffer must be an odd number buffer only. The number of the CC part buffer must be
its host part buffer number + 1.
• The host must set only a host part buffers configuration in the configuration state. CC part buffers
of double transmit message buffers will be initialized by the same configuration automatically.
• In normal mode of operation host operates only with the host part buffers control and status fields.
It has read-only accesses to the CC part buffers control and status fields (see Section 3.4.1,
“Message Buffer Control, Configuration and Status Register”).
It is possible to configure from 0 to 59 message buffers as single transmit message buffers, or 29 double
transmit message buffers, or different mixtures of single and double transmit message buffers (for
example, 15 single transmit message buffers + 22 double transmit message buffers).
3.5.4.3
Receive FIFO Configuration
FIFO Receive buffers can be configured only in the configuration state. First, the host must set the FIFO
size register (see Section 3.2.3.7.1, “FIFO Size Register (FSIZR)”).
NOTE
The FIFO is configured only via the FSIZR register.
The host can write the FIFO size register only during the configuration state. The configuration must be
done in accordance with the configuration procedure and principles.
If a configuration includes FIFO buffers, message buffer 0 must be the first FIFO buffer (see Figure 3-134).
The subset of FIFO buffers must be contiguous.
It is possible to configure up to 59 message buffers as FIFO receive message buffers.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
171
MFR4200 FlexRay Communication Controller
3.5.5
Buffer Reconfiguration in the Normal State of Operation
Reconfiguration procedure during the normal state of operation:
The host must follow the configuration principles and procedure as well as reconfiguration principles,
while reconfigures the message buffers during normal operation.
Reconfiguration principles:
1. Only single transmit message buffers for dynamic segment (STBDS) are reconfigurable in normal
operation.
2. States and parameters that are reconfigurable:
— Parameters of STBDS accessible for host write operations (see Section , “Receive, receive
FIFO, and transmit message buffers are accessible to the host MCU only through the active
receive, active transmit, and active receive FIFO buffers.” and Section 3.4.1, “Message Buffer
Control, Configuration and Status Register”).
3. Buffers, states and parameters that are not reconfigurable:
— FIFO size
— Double transmit message buffers
— Receive message buffers
— Buffers from transmit message buffers to receive message buffers, and vice versa
— All the filtering parameters (channel filters configuration, frame ID filters configuration
(except single transmit message buffers for dynamic segment), message ID filters configuration
and masks, message buffer filtering configuration)
— Buffers cannot be reassigned from static to dynamic segment, or vice versa.
— FIFO
— Buffers cannot be reconfigured from single to double transmit message buffers, or vice versa.
— Buffers assigned to the static segment are not reconfigurable
Figure 3-135 shows how CC buffers can be configured and reconfigured during the configuration state, and
reconfigured during the normal state of the CC:
MFR4200 Data Sheet, Rev. 0
172
Freescale Semiconductor
Message Buffer Handling and Operations
Single/double
transmit
message buffer,
static segment
Double transmit
message buffer,
dynamic
segment
Receive
message buffer
Single transmit
message buffer,
dynamic
segment
Transition in the Normal and in the Configuration states
Transition in the Configuration state
Figure 3-135. Transition Scheme Between Different Buffer Types Depending on Operational Mode of CC
3.5.6
Message Buffer Operations
The main principles of the host and the CC data exchange are as follows.
• The host has full control over the CC.
• After the configuration step is performed by the host, the CC can run the FlexRay protocol. The
CC does not require any additional support from the host for operation in a cluster without faults
and disturbances.
• Data exchange is based on access requests and acknowledge flags.
The host and the CC provide a set of transmit/receive operations for managing data flow between a
FlexRay network and the host.
3.5.6.1
Data collection during Receive Operation
Frames are stored in the CHI if there is at least one receive message buffer or FIFO receive buffer
configured. Therefore, it actively participates in the internal buffer filters matching process, which takes
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
173
MFR4200 FlexRay Communication Controller
place every time the communication controller receives a semantically valid and syntactically correct
frame.
An example of operations during a frame reception is shown on the Figure 3-136.
3.5.6.1.1
The Host Operations during Reception
After every successful frame reception, the CC sets the flag IFLG of a matching buffer. This flag indicates
that a frame has been received and stored in a buffer, and the host can read it to empty the buffer for the
next reception. All IFLG bits are logically OR’ed and connected to the host interrupt line. The host receives
an interrupt if at least one IFLG is set and not masked by the appropriate IENA bit in the BUFCSnR
register.
To read a receive message buffer the host must perform the following steps:
1. Process an interrupt by reading the ISR registers, if necessary. or check the IFLG bits of receive
message buffers.
2. Locate one IFLG interrupt source register by reading the receive message buffer interrupt vector
register (see Section 3.2.3.6, “Interrupt and Error Signaling Related Status Registers”).
3. Send a lock request (write LOCK bit with the value ‘1’) for the corresponding message buffer, to
make it accessible through the active receive message buffer.
4. Wait for lock acknowledge (LOCK bit reads as value ‘1’).
5. Read the active receive message buffer.
6. Send an unlock request for the message buffer.
MFR4200 Data Sheet, Rev. 0
174
Freescale Semiconductor
Message Buffer Handling and Operations
Time
Host Operations
Host receives an IFLG interrupt
and locks the buffer by sending
a lock request (writes ‘1’ to the
LOCK bit) and checking the
acknowledge LOCK1 bit
Buffer is locked by Host and
performs read/write
operation with the buffer
..
..
Buffer is still locked by Host
and performs read/write
operation with the buffer
Buffer is still locked by Host.
It has finished read/write
operation with the buffer and
unlocks it by sending an
Unlock request (writes ‘1’
again to the LOCK bit.
Buffer is unlocked and
IFLG is reset to ‘0’
Host receives an IFLG
interrupt
0
1
1
DATA0
DATA0
DATA0
DATA0
DATA0
DATA0
Receive Message Buffer A
1
1
1
1
1
0
1
0
0
Shadow Buffer
DATA1 Reception
DATA1 Reception
DATA1 Reception
DATA1
CC Operations
CC received a new message for
buffer A updated the buffer
..
CC starts reception of a new
message that matches the
filtering conditions of buffer A
after at least one
communication cycle
CC continues reception of the
new message
CC continues reception of the
new message
CC received the new
semantically valid frame
CC in the shadow buffer with buffer A
Note:
Read back value of the bit.
1
175
Freescale Semiconductor
...
...
IFLG
IFLG
IFLG
IFLG
IFLG
IFLG
LOCK1
LOCK1
LOCK1
LOCK1
LOCK1
LOCK1
Buffer is locked
New Frame Reception
Figure 3-136. Operations During a Frame Reception
MFR4200 Data Sheet, Rev. 0
MFR4200 FlexRay Communication Controller
3.5.6.1.2
CC Operations during Reception
The CC receives every frame to a shadow message buffer first, as shown in Figure 3-136.
NOTE
A frame received in slot n and stored in a configured message buffer or FIFO
is accessible to the host, through the CHI, 16 µT after the start of slot n+1.
The CC performs a filtering process based on filter configuration. This process takes place every time the
CC receives a semantically valid and syntactically correct frame. In this process, the CC sequentially
compares all the receive message buffers filters to the received ones. The first message buffer matching all
the filtering requirements will be updated with the new frame. The matching message buffer will be
overwritten, if the message buffer was already full (IFLG = 1). If a received frame does not match the
filtering fields of any receive message buffer, it will be compared with the FIFO filters. If a frame matches
the FIFO filtering parameters, it will be stored in the FIFO; otherwise, it will be ignored. The CC ignores
invalid frames and does not store them in buffers.
The received frame will be stored in the first matching receive message buffer. The search engine starts
after the end of the FIFO, or at message buffer 0 (if no FIFO is configured), and searches upwards. Thus,
if there are two receive message buffers matching the received frame, the frame will always be stored in
the buffer with the lower buffer index. The CC does not check which buffer fits the frame best. Thus, if a
message buffer holds a filtering subset of another message buffer, that message buffer (with the filtering
subset) must be located at the lower message buffer index. The application must manage this.
The matching message buffer will not be updated if it is still locked. If the message buffer is locked after
reception, it will be updated as soon as it is unlocked. If the buffer is locked for more than one
communication cycle and, if the frame, which matches that message buffer filtering, is received twice
during this period, the buffer will be updated with the newer frame, as soon as it is unlocked, and a frame
lost error will be raised to the host (see Section 3.2.3.6.3, “CHI Error Register (CHIER)”). The
corresponding IFLG bit (message buffer is full) is set every time the message buffer is updated, and, if
enabled, a receive interrupt is generated.
In the case of locking, when the host may lock one receive message buffer, the CC has two shadow message
buffers per channel to continue frame reception targeted for any receive message buffers including the
locked one.
NOTE
During the filtering process, the CC must check the payload length field of
a received frame before the CC applies message ID filtering. If the payload
length of a received frame is too small to hold the full message ID value, the
CC performs the message ID filtering with the default message ID value
(0x0).
3.5.6.2
Data Collection during Transmit Operation
Some or all of the message buffers can be configured as transmit message buffers via the BUFCSnR
register sets (see Section 3.4.1, “Message Buffer Control, Configuration and Status Register”). The
configuration of transmit message buffers must comply with the buffer configuration procedure and
MFR4200 Data Sheet, Rev. 0
176
Freescale Semiconductor
Message Buffer Handling and Operations
principles. The CC handles transmit operations differently during the static and dynamic segments of
transmission; it also handles single and double transmit message buffers differently. For transmission, the
CC uses data from configured and committed transmit message buffers only.
The host submits a frame for transmission by committing a message buffer for transmission (BUFCMT
bit) and by subsequent unlocking of the transmit message buffer. The transmit message buffer remains
valid for transmission until its VALID bit = 1.
To prepare a transmit message buffer for transmission, the following steps must be performed.
1. Configure the message buffer as a transmit message buffer in accordance with the buffer
configuration procedure and principles.
2. Lock the corresponding message buffer, to make it accessible in the active transmit message
buffer. Buffer locking must be done in accordance with the locking/unlocking procedure and
principles
3. Write/read the active transmit message buffer to change or update the message buffer content.
4. Commit the message buffer for transmission, by setting the BUFCMT bit to ‘1’.
5. Unlock the message buffer.
Commitment-to-transmission time for single and double transmit message buffers:
To transmit a frame in slot n, the host must commit and unlock the buffer:
• Static segment transmit message buffer: 4 µT before the beginning of slot n-1 or the network idle
time (NIT).
• Dynamic segment transmit message buffer: 4 µT before the beginning of slot n-1 or the network
idle time (NIT).
Static segment:
For the static segment, if there are several frames pending for transmission, the frame with the ID
corresponding to the next sending slot is selected for transmission. The CC checks other filtering fields of
those messages. If several frames are suitable for current static slot transmission, the CC performs an
internal arbitration.
The CC transmission procedure is described in detail in the frame processing section of the PWD. The
most important points are as follows.
• Only valid frames (VALID bit = 1) can be transmitted by the CC.
• If there are valid frames with the same frame ID, the CC checks their filter fields. If two or more
of them match the conditions of the transmit slot, the message buffer with the lowest message
buffer number wins the internal arbitration.
• If two buffers are assigned to the same static slot but to different transmission channels, the CC
transmits them simultaneously on assigned channels during transmission of that static slot.
• If a message buffer was committed for transmission (BUFCMT = 1) it becomes valid (VALID = 1)
after buffer unlock operation, and the host cannot lock it until it is transmitted at least once.
The CC changes the following bits, if a message from a message buffer has been sent.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
177
MFR4200 FlexRay Communication Controller
•
•
•
IFLG
BUFCMT
VALID (depending on the TT bit of the BUFCSnR register — see Section 3.4.1, “Message Buffer
Control, Configuration and Status Register)
Dynamic segment
In the dynamic segment, if several valid frames are pending within the interface, the frame with the highest
priority (lowest frame ID) is selected next.
The CC transmission procedure is described in detail in the frame processing section of the PWD
document. The most important points are as follows.
• In the dynamic segment, different minislot sequences are possible on both channels (concurrent
sending of different IDx on both channels).
• Pending frames are selected in accordance with their identifier and their filter configuration.
• Frames overlapping with the network idle time (NIT), defined by the NITCR (see
Section 3.2.3.3.18, “Network Idle Time Configuration Register (NITCR)”), will be not
transmitted.
• If there are two or more transmit message buffers with the same identifier, the message buffer with
the lowest number wins the internal arbitration and will be transmitted; the remaining message
buffer(s) with matching filters will be removed from the arbitration process until the next
communication cycle.
• If a message buffer was committed for transmission (BUFCMT= 1) it becomes valid (VALID = 1)
after the buffer unlock operation. The host cannot lock it until it is transmitted; this prevents
changing of a message buffer’s fields, while it is waiting to be transmitted.
• Only valid frames (VALID bit = 1) can be transmitted by the CC.
• Only identifiers that are higher than the highest static identifier are allowed for the dynamic
segment.
• If there are valid frames with the same frame ID, the CC must check their filter fields. If two or
more of them match the conditions of the transmit slot, the message buffer with the lowest address
wins the internal arbitration.
• The CC does not transmit null frames in the dynamic segment.
• If two message buffers are assigned to the same dynamic slot but to different transmission channels,
the CC transmits them on the same minislot number and assigned channels during transmission of
that dynamic slot.
The CC changes the following bits if the message buffer has been sent.
1. IFLG
2. BUFCMT
3. VALID (depending on the TT bit of the BUFCSnR register — see Section 3.4.1, “Message Buffer
Control, Configuration and Status Register)
MFR4200 Data Sheet, Rev. 0
178
Freescale Semiconductor
Message Buffer Handling and Operations
3.5.6.2.1
Single Transmit Message Buffer Data collection during Transmit Operation
The host can configure some message buffers of the CC as single transmit message buffers. If there is at
least one transmit message buffer configured, or the sync frame register value (see Section 3.2.3.3.29,
“Sync Frame Register (SYNCFR)”) is not 0x0, the CC can actively transmit frames out of the connected
FlexRay network.
To configure a single transmit message buffer, the following next steps must be performed.
1. Configure the message buffer as a transmit message buffer, in accordance with the configuration
procedure and principles.
2. Set the message buffer type bit (BT) to 0 — single transmit message buffer.
After a buffer is configured as a single transmit message buffer and a CC enters the normal mode of
operation, The host can start preparation and commitment of frames for transmission. Figure 3-137 shows
an example of host and CC operation on a single transmit message buffer during frame transmission in
normal operation.
As shown in Figure 3-137, The host sends a lock request for a message buffer and always checks for the
lock request acknowledge bit LOCK to be a ‘1’ before it starts to update the message buffer content (see
Section 3.5.3.4, “Active Buffers Locking/Unlocking and Locking Timing” and Section 3.2.3.6.3, “CHI
Error Register (CHIER)” for more information).
After a transmit message buffer is locked, the host can update it, via the active transmit message buffer,
and can commit it to transmission by setting the BUFCMT bit to ‘1’ and unlocking the message buffer.
After transmission, the CC sets the IFLG bit of a message buffer, and clears BUFCMT. The CC changes
the VALID bit after transmission depending on the TT bit.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
179
MFR4200 FlexRay Communication Controller
Transmit Message Buffer with
Frame ID = A
VALID
IFLG
1
BUFCMT
1
1
1
0
1
1
LOCK
BUFCMT
1
BUFCMT
0
LOCK
BUFCMT
0
LOCK
1
1
1
IFLG
0
Transmission of Null Frame
...
...
...
...
...
...
...
...
DATA1
...
CC transmits
DATA1
DATA1
...
DATA1
Transmission of DATA1
1
CC transmission
request.
Access granted
...
0
Transmission
Done
DATA1
...
BUFCMT
0
LOCK
1
DATA1
CC transmits a
Null Frame
because the
buffer is locked
by Host and
there is no other
matching buffer
...
1
DATA1
...
BUFCMT
0
CC transmission
on request.
Access not
granted because
Host locked the
buffer
DATA1
...
BUFCMT
LOCK
0
LOCK
1
1
1
1
IFLG
0
VALID
0
IFLG
1
VALID
BUFCMT
BUFCMT
LOCK1
1
LOCK
LOCK
IFLG
1
1
1
VALID
0
IFLG
1
VALID
IFLG
1
VALID
1
1
Time
1
1
Unlock Request
(Host writes LOCK = 1)
0
VALID
Host updates data
and commits buffer
for transmission
Lock Request
(Host writes LOCK=1)
0
IFLG
Lock Request
(Host writes LOCK=1)
but access not granted
because CC locked
the buffer.
1
VALID
Lock Request
(Host writes LOCK=1)
but access not granted
because CC locked
the buffer.
1
IFLG
Unlock Request
(Host writes LOCK=1)
0
VALID
Host updates data
and commits buffer
for transmission
Lock Request
(Host writes LOCK=1)
CC Operations
...
Host Operations
Transmission
Done
DATA2
DATA2
Note:
1
Read back value of the bit.
Figure 3-137. Operations with a Single Transmit Message Buffer during an Event Type of Transmission for
a Static Segment
MFR4200 Data Sheet, Rev. 0
180
Freescale Semiconductor
Message Buffer Handling and Operations
3.5.6.2.2
Doubled Buffer Data collection during Transmit Operation
The host can configure some message buffers of the CC as double transmit message buffers. If there is at
least one double transmit message buffer configured, then the CC can actively transmit frames out of the
connected FlexRay network.
To configure a double transmit message buffer (Figure 3-138), the follow steps must be performed.
1. Configure the even number message buffer as a transmit message buffer, in accordance with the
configuration procedure and principles.
2. Set the message buffer type bit BT (see Section 3.4.1, “Message Buffer Control, Configuration
and Status Register”) to 1 — host part buffer of double transmit message buffers (configuration is
copied to the CC part buffers automatically).
The Figure 3-139 shows an example of a double transmit message buffer data collection during the state
driven transmit operation in normal operation.
The Figure 3-140 shows an example of a doubled transmit message buffer data collection during the event
driven transmit operation.
NOTE
When the CC transmits a null frame, it does not change the BUFCSnR
registers of the buffers.
Buffer
number
(even)
Host Part Buffer n
Buffer
Number+1
(odd)
BUFCS(n)
CC part Buffer n+1
BUFCS(n+1)
Figure 3-138. Double Transmit Message Buffer Structure
Host Operations with a Double Transmit Message Buffer during Transmission
The host can perform the following operations on a double transmit message buffer.
• Lock buffer for reading and/or modifying.
• Read message buffer slot status vector, data and configuration.
• Write data.
• Commit and unlock for transmission.
Main principles of the host operations with double transmit message buffers:
•
•
•
•
•
•
The host always operates with host part buffers.
The host can perform operations with host part buffers independent of CC transmit operations from
the CC part buffers.
Data exchange is based on access requests and acknowledge flags.
The host and the CC operate only with configured buffers that have frame ID field not equal to ‘0’.
The addresses of the host part buffers do not change during normal operation.
The host has read-only access to the CC part buffer BUFCSnR registers.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
181
MFR4200 FlexRay Communication Controller
•
•
•
•
•
The host operates with a double transmit message buffer in the same way as it does with a single
transmit message buffer.
The host can receive an IFLG interrupt after transmission of a committed CC part buffer.
The host cannot lock a host part buffer (read value of the LOCK= 0) during swap and copy
procedures.
The host part buffer of a double transmit message buffer cannot be locked (read back value of the
LOCK= 0), if the host has committed the host part buffer for transmission but the BUFCMT bit of
the CC part buffer is still ‘1’ (a frame has not yet been transmitted).
if the host has committed a host part buffer of a double message buffer for transmission, the CC
performs an atomic swap of the host part and CC part buffers including the BUFCSnR registers of
the host and the CC part buffers, and starts a copy process.
CC Operations with a Double Transmit Message Buffer During Transmission
The CC performs the following operations on a double transmit message buffer.
1. Lock buffer for transmission.
2. Update the message buffer slot status vector of the host and the CC part buffers.
3. Swap host and CC part buffers after commitment for transmission.
4. Copy the CC part buffer to the host part buffer during commitment for transmission. The CC
copies the following fields from a CC part buffer of a double transmit buffer to a host part buffer
(see Section 3.5, “Message Buffer Handling and Operations”):
— R*
— PP
— Frame ID
— Payload length
— Header CRC
— Data[0:31]
— Message buffer slot status vector
Main principles of CC operations with double transmit buffers:
•
•
•
•
The CC may perform transmit operations from the CC part buffers while the host updates the host
part buffers.
Data exchange is based on access requests and acknowledge flags.
The host and the CC operate only with configured buffers that have frame ID fields not equal to ‘0’.
The numbers of the CC part buffers do not change during normal operation.
As it is presented in Section 3.5.6, “Message Buffer Operations”, host operations on a host part of a double
transmit message buffer are the same as they are on a single transmit message buffer. However, CC
operations with host part and CC part buffers are different.
MFR4200 Data Sheet, Rev. 0
182
Freescale Semiconductor
Message Buffer Handling and Operations
Table 3-17. Double Transmit Message Buffer Data Collection with State Driven Transmit Operation
Time
Point
Host Operations
CC Operations
1
The host sends a lock request to a host part buffer of a –
double transmit message buffer (it writes LOCK=’1’) and
receives a request acknowledge (read back value of the
LOCK=’1’).
2
The host part buffer is locked. The host updates the buffer The CC starts frames transmission and sends a buffer lock
contents.
request for CC part buffer to transmit the frame this buffer
holds.
3
The host part buffer is locked. The host updates the buffer The CC locked the CC part buffer and transmits the frame
contents.
from it
4
The host part buffer is locked. The host finished data
The CC finished transmission and updates the BUFCMT,
update (buffer holds the DATA1), committed the buffer for VALID and IFLG bits of the CC part buffer
transmission (BUFCMT=’1’) and sent an unlock request
(it writes again LOCK=’1’)
5
Unlock granted.
The CC clears the IFLG bit of the host part buffer to ‘0’ and
sets the VALID bit. The CC performs an atomic swap of the
host part and CC part buffers including the BUFCSnR
registers and starts a copy process.
6
–
The atomic swap of the host part and CC part buffers is
done. The CC starts the copy process from the new CC
part buffer to the host part buffer. BUFCMT bit of the host
part buffer is ‘1’ until those processes are finished (The
host cannot lock the host part buffer).
7
–
The CC continues the copy process and starts frames
transmission. The CC sends a buffer lock request for CC
part buffer to transmit the frame this buffer holds.
8
The host sends a lock request to a host part buffer of a The CC continues the copy process.The CC locked the
double transmit message buffer (it writes LOCK=’1’) but CC part buffer and transmits the frame from it.
does not receive a lock request acknowledge (read back
value of the LOCK=’0’) due to the copy process running.
9
–
10
The host sends a lock request to a host part buffer of a The CC transmits the frame from the CC part buffer.
double transmit message buffer (it writes LOCK=’1’) and
receives a request acknowledge (read back value of the
LOCK=’1’) and has starts to update data in the host part
buffer.
The CC transmits the frame from the CC part buffer. The
CC finished the copy process (The host can lock the
buffer).
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
183
MFR4200 FlexRay Communication Controller
Time
1
2
3
4
5
6
Host Operations
Lock Request
(Host writes LOCK=1)
Unlock Request
(Host writes LOCK=1)
1
1
1
0
0
DATA1
DATA1
Buffer locked
DATA0
Buffer locked
DATA0
Host part buffer — even part of a
double buffer (even buffer number)
0
1
0
0
0
1
1
1
1
0
0
Invalid data during
copy process for DATA1
Swap
Copy Process
DATA1
1
1
1
0
0
DATA1
Buffer locked by CC
DATA1
Buffer locked by CC
DATA0
DATA0
Buffer locked by CC
DATA0
Buffer locked by CC
DATA0
CC part buffer — odd part of a
double buffer (odd buffer number)
1
0
0
1
1
1
1
1
1
0
0
1
1
CC Operations
CC transmission
request
CC transmits
DATA0
Transmission done
CC performs atomic swap
operation of two buffers
CC transmits
DATA0
CC transmission
request
CC performs a copy process
Transmission of DATA0
Transmission done
Transmission of DATA1
7
0
0
1
1
Lock Request
(Host writes LOCK=1)
1
1
8
Lock not granted
0
0
9
Lock Request
(Host writes LOCK=1)
10
Note:
Read back value of the bit.
1
...
...
...
...
...
Freescale Semiconductor
184
...
...
...
...
...
...
...
...
...
...
...
BUFCMT
BUFCMT
BUFCMT
BUFCMT
BUFCMT
BUFCMT
IFLG
IFLG
VALID
VALID
IFLG
IFLG
VALID
VALID
IFLG
IFLG
BUFCMT
BUFCMT
BUFCMT
BUFCMT
BUFCMT
BUFCMT
LOCK1
LOCK1
IFLG
IFLG
VALID
VALID
VALID
VALID
IFLG
LOCK1
LOCK1
LOCK1
LOCK1
IFLG
VALID
VALID
IFLG
IFLG
VALID
VALID
Host updates data
and commits buffer
for transmission
Host updates
data and
commits
buffer for
transmission
Figure 3-139. Doubled Buffer Data Collection with State Driven Transmit Operation
MFR4200 Data Sheet, Rev. 0
Message Buffer Handling and Operations
Time
1
2
3
4
5
6
Host Operations
Lock Request
(Host writes LOCK=1)
Unlock Request
(Host writes LOCK=1)
0
1
1
1
1
0
0
DATA1
DATA1
Buffer locked
DATA0
Buffer locked
DATA0
Host part buffer — even part of a
double buffer (even buffer number)
0
1
1
1
0
1
0
1
1
Invalid data during
copy process for DATA1
Swap
Copy Process
DATA1
0
1
1
0
0
DATA1
Buffer locked by CC
DATA1
Buffer locked by CC
DATA0
DATA0
Buffer locked by CC
DATA0
Buffer locked by CC
DATA0
CC part buffer — odd part of a
double buffer (odd buffer number)
0
0
0
1
1
0
0
1
1
0
0
1
1
CC Operations
CC performs atomic swap
operation of two buffers
CC performs a copy process
CC transmission
request
CC transmits
DATA0
Transmission done
Transmission of DATA1
7
0
0
0
Lock Request
(Host writes LOCK=1)
1
1
8
Lock not granted
1
0
9
1
Note:
Read back value of the bit.
1
...
185
Freescale Semiconductor
...
...
...
...
...
...
...
BUFCMT
BUFCMT
BUFCMT
BUFCMT
BUFCMT
IFLG
IFLG
VALID
VALID
IFLG
IFLG
VALID
VALID
BUFCMT
Lock Request
(Host writes LOCK=1)
10
LOCK
IFLG
IFLG
BUFCMT
BUFCMT
LOCK
1
1
IFLG
IFLG
VALID
VALID
VALID
VALID
BUFCMT
BUFCMT
BUFCMT
BUFCMT
LOCK1
LOCK
LOCK
LOCK
IFLG
1
1
1
IFLG
VALID
VALID
IFLG
IFLG
VALID
VALID
Host updates data
and commits buffer
for transmission
Host updates
data and
commits
buffer for
transmission
Figure 3-140. Doubled Buffer Data collection with Event Driven Transmit Operation
MFR4200 Data Sheet, Rev. 0
MFR4200 FlexRay Communication Controller
Table 3-18. Double Transmit Message Buffer Data Collection with Event Driven Transmit Operation
Time
Point
Host Operations
CC Operations
1
The host sends a lock request to a host part buffer of a
The Valid bit of the CC part buffer is ‘0’ – data is not valid
double transmit message buffer (it writes LOCK=’1’) and and the CC does not transmit frame containing data from
receives a request acknowledge (read back value of the this buffer
LOCK=’1’).
2
The host part buffer is locked. The host updates the buffer The Valid bit of the CC part buffer is ‘0’ – data is not valid
contents.
and the CC does not transmit frame containing data from
this buffer
3
The host part buffer is locked. The host updates the buffer The Valid bit of the CC part buffer is ‘0’ – data is not valid
contents.
and the CC does not transmit frame containing data from
this buffer
4
The host part buffer is locked. The host finished data
The Valid bit of the CC part buffer is ‘0’ – data is not valid
update (buffer holds the DATA1), committed the buffer for and the CC does not transmit frame containing data from
transmission (BUFCMT=’1’) and sent an unlock request this buffer
(it writes again LOCK=’1’)
5
Unlock granted.
The CC clears the IFLG bit of the host part buffer to ‘0’ and
sets the VALID bit. The CC performs an atomic swap of
the host part and CC part buffers including the BUFCSnR
registers and starts a copy process.
6
–
The atomic swap of the host part and CC part buffers is
done. The CC starts the copy process from the new CC
part buffer to the host part buffer. BUFCMT bit of the host
part buffer is ‘1’ until those processes are finished (The
host cannot lock the host part buffer).
7
–
The CC continues the copy process and starts frames
transmission. The CC sends a buffer lock request for CC
part buffer to transmit the frame this buffer holds.
8
The host sends a lock request to a host part buffer of a
The CC continues the copy process.The CC locked the
double transmit message buffer (it writes LOCK=’1’) but CC part buffer and transmits the frame from it.
does not receive a lock request acknowledge (read back
value of the LOCK=’0’) due to the copy process running.
9
–
10
The host sends a lock request to a host part buffer of a
The CC transmits the frame from the CC part buffer.
double transmit message buffer (it writes LOCK=’1’) and
receives a request acknowledge (read back value of the
LOCK=’1’) and has starts to update data in the host part
buffer.
3.6
The CC transmits the frame from the CC part buffer. The
CC finished the copy process (The host can lock the
buffer).
Receive FIFO Function
Some or all of the message buffers can be configured as a receive first-in-first-out (FIFO) system.
The FIFO always starts at message buffer 0 and can be configured to a maximum of 59 message message
buffers by means of the FIFO size register (see Section 3.2.3.7.1, “FIFO Size Register (FSIZR)”).
MFR4200 Data Sheet, Rev. 0
186
Freescale Semiconductor
Receive FIFO Function
Every incoming frame not matching any receive filter, but matching the programmable FIFO filters, is
stored in the FIFO buffer system. In this case, the received frame and its message buffer slot status vector
are stored in the next FIFO message buffer, including. There are two status bits in ISR0 (see the RFNEIF
and RFOIF bits in Section 3.2.3.6.6, “Interrupt Status Register 0 (ISR0)”): one shows that the receive FIFO
is not empty; the other shows that a receive FIFO overrun has been detected. Interrupts are generated, if
interrupts are enabled.
•
•
NOTE
The CC does not store null frames and invalid frames in FIFO.
If the CC has two channels configured, then, during the static part of
transmission, the CC stores in the FIFO first the frame received on
channel A, and then the frame received on channel B. All FIFO filtering
conditions must match for both received frames.
There are two internal (not host accessible) index registers associated with each FIFO. The PUT index
register (PUTIDX) is used as an index to the next available location in the FIFO buffer system. When a
new frame is received, it is written into the message buffer addressed by the PUTIDX register; the PUTIDX
register is then incremented, to address the next message buffer. If the PUTIDX register is incremented
past the highest FIFO message buffer, the PUTIDX register is reset to 0. The GET index register
(GETIDX) is used to address the next FIFO buffer to be read. The GETIDX register is incremented when
unlocking one of the receive FIFO buffers. The FIFO buffer system is completely filled when the PUT
pointer (PUTIDX) reaches the value of the GET pointer (GETIDX). New incoming frames cannot be
stored in the FIFO. The FIFO overrun flag is set at the end of this frame if no error has occurred. A receive
FIFO non empty status is detected when the PUTIDX register differs from the GETIDX register. This
indicates that there is at least one received frame in the FIFO buffer system.
The PUTIDX register and the GETIDX register cannot be accessed by the host.
The FIFO empty, FIFO not empty, and FIFO overrun situations are explained in Figure 3-141.
PUTIDX
(WRITE)
PUTIDX
(WRITE)
PUTIDX
(WRITE)
0
1
2
0
1
2
0
1
2
–
–
–
A
–
–
A
B
C
GETIDX
(READ)
GETIDX
(READ)
GETIDX
(READ)
PUTIDX was incremented
last + new incoming
message (which is lost)
FIFO Empty
FIFO Not Empty
FIFO Overrun
Figure 3-141. FIFO Status (Empty, Not Empty, Overrun) — Example of FIFO with Three Message Buffers
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
187
MFR4200 FlexRay Communication Controller
To read a receive FIFO buffer, the host must lock the FIFO buffer by sending a lock request (LOCK=’1’)
to message buffer 0. When a FIFO buffer is locked (read back value of the LOCK=’1’), the message buffer
addressed by GETIDX appears in the active receive FIFO buffer. After reading, the FIFO buffer must be
unlocked, and the GETIDX pointer is incremented.
The complete set of FIFO acceptance/rejection filters consists of the following registers (see
Section 3.2.3.8, “Filtering Related Registers”).
Two filter sets are available for FIFO filtering:
• One FIFO acceptance filter set, comprising:
— FIFO acceptance filter message ID value register
— FIFO acceptance filter message ID mask register
• One FIFO rejection filter set, comprising:
— FIFO rejection filter frame ID value register
— FIFO rejection filter frame ID mask register
• The channels from which the received frame will be accepted or rejected by the FIFO
acceptance/rejection filters are specified in Section 3.2.3.8.7, “FIFO Acceptance/Rejection Filter
Channel Register (FAFCHR)”.
The FIFO acceptance filter value registers define the acceptable pattern of the frame to be received. The
FIFO acceptance filter mask registers specify which of the corresponding bits are marked ‘don’t care’ for
acceptance filtering.
The FIFO rejection filter value registers define the acceptable pattern of the frame to be rejected. The FIFO
rejection filter mask registers specify which of the corresponding bits are marked ‘don’t care’ for rejection
filtering.
If acceptance and rejection filter are configured to match the same identifier, the frame will be rejected.
•
•
•
NOTE
The content of the FIFO is not reset by entering, being in, or leaving the
configuration state. Therefore, if the CC has stored any messages in the
FIFO, and has entered the configuration state without reading those
messages, and has returned to normal operation, then those messages
will remain in the FIFO.
The CC automatically updates the BUFCSnR registers of the FIFO
buffers to 0x0 values when the CC enters the configuration state for the
first time.
The host must clear buffer control flags CFG, IFLG, and IENA (write
0x0000 to the buffer control register) of a message buffer that has
already been in use or that has already been configured, before the host
may extend the FIFO (alter the FIFO size) to include that message buffer
in the FIFO. Failing to do so will result in invalid indications in the
RBIVEC/TBIVEC registers (see Section 3.2.3.6.1, “Receive Buffer
Interrupt Vector Register (RBIVECR)” and Section 3.2.3.6.2, “Transmit
Buffer Interrupt Vector Register (TBIVECR)”), i.e. RBIVEC/TBIVEC
MFR4200 Data Sheet, Rev. 0
188
Freescale Semiconductor
Host Controller Interfaces
will still indicate asserted IFLG bits for the message buffer that has been
included in the FIFO.
3.7
Host Controller Interfaces
The FlexRay communication controller can be connected and controlled by two types of microcontrollers
through the CC MCU interface. Two pins, IF_SEL0 and IF_SEL1, configure the interface for the type of
MCU. The MCU type is selected by IF_SEL0 and IF_SEL1 inputs as shown in Table 3-19.
Table 3-19. FlexRay CC MCU Interface Configuration
Mode
IF_SEL0
IF_SEL1
Unsupported
0
0
HCS12
0
1
AMI
1
0
Unsupported
1
1
When it leaves the hard reset state, the CC latches the values of the IF_SEL0 and IF_SEL1 signals and
configures the interface for the type of MCU accordingly. The CC does not analyze IF_SEL0 and IF_SEL1
after it has left the hard reset state (see Section 3.9.1, “Hard Reset State”).
NOTE
If the CC senses the unsupported mode on its IF_SEL pins, it stops all
internal operations, does not perform/respond on any host transactions,
stays in the configuration mode, and does not integrate into the
communication process. The following steps must be taken to select a
correct MCU interface mode.
1. IF_SEL0, IF_SEL1 must be set to the AMI or HCS12 mode.
2. The hard reset signal of the CC must be asserted again.
3.7.1
MFR4200 Asynchronous Memory Interface
The MFR4200 asynchronous memory interface is shown in Figure 3-142. This interface has the following
characteristics and features:
• Data exchange in AMI mode is controlled by the CE#, WE# and OE# signals.
• The MFR4200 AMI is implemented as an asynchronous memory slave module, thus enabling fast
interfacing between the CC and a variety of microcontrollers.
• The MFR4200 AMI decodes its internal registers addresses with the help of the chip select signal
CE# and the address lines A[9:1].
NOTE
The address space from 0x0400 to 0x1FFF is reserved. Reading this address
space results in data 0x0000, while writing will not change the memory.
Reading or writing this address space will set the ILLADR bit in CHIER.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
189
MFR4200 FlexRay Communication Controller
•
•
•
•
•
The AMI module accepts only 16-bit wide (word) transactions. It does not have byte select lines
and, thus, does not recognize 8-bit wide accesses. Therefore, it does not indicate errors in the event
of 8-bit transactions.
The WE# signal indicates the direction of data transfer for a transaction.
The OE# signal enables the AMI data output to a microcontroller during read transactions.
INT_CC# is an interrupt line that can be used for requesting, by means of the internal interrupt
controller, a service routine from a host controller.
The MFR4200 AMI module does not support burst transactions.
Microcontroller
MPC5xx
...
D15
...
D15
D0
A22
...
...
A9
...
D0
...
...
...
MFR4200
A1
A30
WE#
WE#
CSn#
OE#
CE#
OE#
VDDIO
INT_CC#
IRQn#
VDDIO
To the PHY
IF_SEL0/BGT/DBGT
To the PHY
IF_SEL1/TXD_BG1/TXD_485
Figure 3-142. Connecting MFR4200 to MPC5xx Using the AMI (Example)
MFR4200 Data Sheet, Rev. 0
190
Freescale Semiconductor
Host Controller Interfaces
Microcontroller
MAC71xx
...
D15
...
D0
D0
A9
...
...
A9
...
D15
...
...
...
MFR4200
A1
A1
RD/WR#
WE#
CSn#
OE#
CE#
OE#
VDDIO
INT_CC#
IRQn#
VDDIO
To the PHY
IF_SEL0/BGT/DBGT
To the PHY
IF_SEL1/TXD_BG1/TXD_485
Figure 3-143. Connecting MFR4200 to MAC71xx Using the AMI (Example)
Microcontroller
DSP56F83x
...
D15
...
D0
D0
A9
...
...
A9
...
D15
...
...
...
MFR4200
A0
A1
WR#
WE#
CSn#
RD#
CE#
OE#
VDDIO
INT_CC#
IRQn#
VDDIO
To the PHY
IF_SEL0/BGT/DBGT
To the PHY
IF_SEL1/TXD_BG1/TXD_485
Figure 3-144. Connecting MFR4200 to DSP56F83x (Hawk) Using the AMI (Example)
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
191
MFR4200 FlexRay Communication Controller
3.7.1.1
AMI Interface Signals and Pins Description
Table 3-20. AMI Interface Signals and Pins Description
Signal name
MCU External Bus and
Memory Controller Pin
FlexRay CC MCU
Interface Pin
Function Description
Name
I/O
Name
I/O
D[15:0]
D[15:0]
I/O*
D[15:0]
I/O
A[9:1]
A[9:1]
O
A[9:1]
I
Address Bus, A1 is the LSB of address
RD/WR#
RD/WR#
O
WE#
I
Read/Write – Indicates the direction of the data
transfer for a transaction. A logic one indicates a
read from a slave device; a logic zero indicates a
write to a slave device.
OE#
OE#
O
OE#
I
Output Enable Signal, controls AMI data output
during read transactions
IRQn#
IRQn#
I
INT_CC#
O
Interrupt Request (level sensitive) – One of the
eight external lines that can request, by means of
the internal interrupt controller, a service routine
from the MPC555.
IF_SEL[0:1]
–
–
IF_SEL[0:1]
I
Interface Select – FlexRay CC MCU interface
configuration pins
CSn#
CSn#
O
CE#
I
Chip Select/Chip Enable – These signal enable
peripheral or memory devices at programmed
addresses if defined appropriately in the memory
controller.
Data Bus, D0 is the LSB of data
Where:
I – input pin; O – output pin; I/O – input/output pin
3.7.2
MFR4200 HCS12 Interface
The MFR4200 HCS12 interface with HCS12 EBI paged mode support is shown in Figure 3-145.
The FlexRay CC to HCS12 connection with HCS12 EBI unpaged mode support is shown in Figure 3-146.
• The MFR4200 HCS12 interface supports the paged and unpaged modes of the HCS12 external bus
interface connected to it.
• The MFR4200 HCS12 interface is implemented as a synchronous HCS12 external bus slave
module, thus enabling fast data exchange between them.
• The MFR4200 HCS12 interface decodes addresses of read/write transactions to its internal
registers and generates its internal CS signal with the use of the address/data lines PAD[0:15],
ACS[0:5] and XADDR[14:19] (see Figure 3-147).
— The address and data lines PAD[0:15] are multiplexed. They are denoted ADR[0:15] when
referring to the address and DATA[0:15] when referring to the data. The MFR4200 is selected
only when the address ADR[10:15] matches ACS[0:5] (ADR[10] matches ACS[0], ADR[11]
matches ACS[1], etc.), and the address XADDR[14:19] matches 0.
MFR4200 Data Sheet, Rev. 0
192
Freescale Semiconductor
Host Controller Interfaces
•
•
•
The HCS12 interface module accepts only aligned 16-bit wide read/write and 8-bit wide read
transactions. The FlexRay CC module does not support 8-bit wide write accesses. The error
indication bit ILLADR (illegal address) is raised in the CHIER (see Section 3.2.3.6.3, “CHI Error
Register (CHIER)”) in the event of an 8 bit write transaction, or if an unaligned half word
transaction is performed (detected if ADR[0] is equal to 1 or if LSTRB is equal to 1). Data 0x0000
is presented to the host in this case.
the RW_CC# signal indicates the direction of data transfer for a transaction.
INT_CC# is an interrupt line that can be used for requesting, by means of the internal interrupt
controller, a service routine from the HCS12 device.
HCS12
ADDR/DATA0
...
...
...
ADDR/DATA15
PAD0
...
MFR4200
PAD15
ACS5
VDDIO
ACS4
VDDIO
ACS3
...
...
VDDIO
...
ACS0
ECLK
ECLK_CC
R/W#
RW_CC#
LSTRB
LSTRB
XADDR14
...
...
...
XADDR14
...
XADDR19
XADDR19
EBI
VDDIO
INT_CC#
IRQn#
VDDIO
To the PHY
IF_SEL1/TXD_BG1/TXD_485
To the PHY
IF_SEL0/BGT/DBGT
Figure 3-145. FlexRay CC to HCS12 Device Connection with HCS12 EBI Paged Mode Support
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
193
MFR4200 FlexRay Communication Controller
HCS12
ADDR/DATA0
...
...
PAD0
...
...
MFR4200
PAD15
ADDR/DATA15
VDDIO
ACS5
...
...
...
VDDIO
ACS0
ECLK
ECLK_CC
R/W#
RW_CC#
LSTRB
LSTRB
6
XADDR[14:19]
EBI
VDDIO
INT_CC#
IRQn#
VDDIO
To the PHY
IF_SEL1/TXD_BG1/TXD_485
To the PHY
IF_SEL0/BGT/DBGT
Figure 3-146. FlexRay CC to HCS12 Device Connection with HCS12 EBI Unpaged Mode Support
MFR4200 Data Sheet, Rev. 0
194
Freescale Semiconductor
Host Controller Interfaces
PAD[0..15]
16 bit
Address
/Data
Demulti
plexer
16 bit
DATA[0..15]
DATA SIGNALS
16 bit
ADR[0..15]
ADDRESS SIGNALS
10 bit
6 bit
16 bit
ADR[10..15]
ADR[0..9]
ADDRESS SIGNALS
Address
Comparator1
6 bit
ACS[0..5]
XADDR[14..19]
&
6 bit
2 bit
ACS[0..5]
XADDR[14..19]
CS
Address
Comparator2
6 bit
1
“000000”
6 bit
“1”
0
C
ADR[14..15]
2 bit
“01”
2 bit
Address
Comparator3
HCS12 Interface of the CC
Figure 3-147. HCS12 interface Address Decoding and Internal CS Signal Generation
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
195
MFR4200 FlexRay Communication Controller
3.7.2.1
HCS12 Interface Signal and Pin Descriptions
Table 3-21. HCS12 Interface Signal and Pin Descriptions
FlexRay CC MCU
Interface Pin
HCS12 External Bus
Signal name
1
Function Description
1
Name
I/O
Name
I/O
AD[0:15]
ADDR/DATA[0:15]
I/O*
PAD[0:15]
I/O
Multiplexed external address data bus (AD0
is the LSB; AD15 is the MSB)
ECLK#
ECLK#
O
ECLK_CC#
I
Internal bus clock output – This output line is
the clock system frequency of the HCS12
XADDR[14:19]
XADDR[14:19]
O
XADDR[14:19]
I
HCS12 interface expanded address lines –
(XADDR14 is the LSB of the HCS12 interface
expanded address lines)
ACS[0:5]
–
–
ACS[0:5]
I
HCS12 interface, address select inputs.
ACS5: MSB of the address select inputs
RD/WR#
RD/WR#
O
RW_CC#
I
Read/Write – Indicates the direction of the
data transfer for a transaction. A logic one
indicates a read from a slave device; a logic
zero indicates a write to a slave device.
LSTRB#
LSTRB#
O
LSTRB#
I
Low-byte Strobe – indicates the type of bus
access
IRQ#
IRQ#
I
INT_CC#
O
Interrupt Request (level sensitive) – One of
the external lines that can request, by means of
the internal interrupt controller, a service
routine from the HCS12.
IF_SEL[0:1]
–
–
IF_SEL[0:1]
I
Interface Select – FlexRay CC MCU interface
configuration pins
I – input pin; O – output pin; I/O – input/output pin
MFR4200 Data Sheet, Rev. 0
196
Freescale Semiconductor
External 4/10 MHz Output Clock
3.8
External 4/10 MHz Output Clock
A continuous external 4/10 MHz output clock signal is provided by the CC on the CLKOUT pin. This
signal is always active after power-up of the CC in all CC states including the hard reset state. The
CLKOUT signal is disabled during the internal power-on and low voltage reset procedures (refer to
Chapter 5, “Clocks and Reset Generator” for more information).
The output frequency of the CLKOUT signal is selected by the CLK_S0, CLK_S1 input pins, in
accordance with Table 3-22.
Table 3-22. CLKOUT Frequency Selection
Pin
CLKOUT Function
CLK_S0
CLK_S1
0
0
4 MHz output
1
0
10 MHz output
0
1
40 MHz output
1
1
Disabled (CLKOUT output is “0“)
NOTE
For information on CLKOUT stabilization timing parameters, refer to
Appendix A, “Electrical Characteristics”.
3.9
3.9.1
Communication Controller States
Hard Reset State
Protocol Operation Control: Initiate hardware state.
During this state, the CC initializes all internal registers to their specified hard reset default state (see
Section 3.2.2, “Register Map Summary”).
In the hard reset state:
• All the operation with protocol state machine are stopped.
• There is no transmission or reception on the FlexRay bus.
• There is no clock synchronization running.
• The CC host interface is stopped.
• The CC analyzes the input signals on the two pins IF_SEL0 and IF_SEL1 while leaving the hard
reset state to configure the interface for the type of MCU (see Section 3.7, “Host Controller
Interfaces”).
The CC enters the hard reset state:
•
According to the state of the hard reset pin (see Section 5.2.2, “Reset Generation and CLKOUT
Control”).
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
197
MFR4200 FlexRay Communication Controller
NOTE
In the hard reset state, the host MCU type is not defined. If the host accesses
the CC during this state, the CC can enter into an unpredictable state.
Therefore, the host is prohibited from performing any accesses to the CC
when the CC is in the hard reset state.
Initialization of the CC is done on leaving the hard reset state, i.e. on a rising edge of the hard reset signal
(see Section 3.2.3.1.3, “Magic Number Register (MNR)”). After leaving the hard reset state, the host must
wait until initialization is complete, before reading or writing to the controller.
During this internal initialization procedure, the CC initializes its internal memory including following
configuration/control parameters of its message buffers.
• Frame ID = 0x0
• CCFnR: Cycle Count Mask and Cycle Counter Value fields = 0
• BUFCSnR:
— BUFCMT = 0
— ChA, ChB = 0
— BT= 0
— CCFE = 0
— TT = 0
— LOCK = 0
— IFLG = 0
— VALID = 0
— IENA = 0
— CFG = 0
— DATAUPD = 0
During the internal initialization procedure the host must not access any of the CC registers except MNR
(see Section 3.2.3.1.3, “Magic Number Register (MNR)), which acknowledges the end of the internal
initialization procedure.
The CC exits the hard reset state and enters the configuration state, after the hard reset signal is negated
(see Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”).
MFR4200 Data Sheet, Rev. 0
198
Freescale Semiconductor
Communication Controller States
3.9.2
Configuration State
Protocol Operation Control: Config state.
During this state, the host configures the CC in accordance with the access scheme for CC internal
resources (see Section , “Receive, receive FIFO, and transmit message buffers are accessible to the host
MCU only through the active receive, active transmit, and active receive FIFO buffers.”) and the
configuration principles (see Section 3.5, “Message Buffer Handling and Operations”).
In the configuration state:
• All operations with the protocol state machine are stopped.
• There is no transmission or reception on the FlexRay bus.
• There is no clock synchronization running.
• The host interface of the CC is operational.
• The host type is fixed after the hard reset state.
• All message buffers, after entering the configuration state from the hard reset state, are “not used”
buffers. The CC stores its configuration if it enters the configuration state from a state other than
the hard reset state.
• If the host puts the CC into the configuration state by setting the CONFIG bit in MCR0 register to
‘1’ (see Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”), the CC configuration data
will be held, except data that is initialized when leaving the configuration state.
On leaving the configuration state, some registers are cleared by the CC (this operation is highlighted in
descriptions of those registers).
The CC enters the configuration state:
• By leaving the hard reset state.
• According to the state of the CONFIG bit in the MCR0 register (see Section 3.2.3.2.1, “Module
Configuration Register 0 (MCR0)”).
• By leaving the sleep state or the diagnosis stop states.
NOTE
The CC enters the configuration state immediately the MCR0 CONFIG bit
is set. This may cause a protocol violation; the user must take care to ensure
that entry to the configuration state does not cause a protocol violation.
The CC exits from the configuration state and enters the normal state of operation (see Section 3.9.4,
“Normal Active State”).
Figure 3-148 represents a timing diagram of the transition from the configuration state to the normal state.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
199
MFR4200 FlexRay Communication Controller
CC is in the
Configuration
State
Configuration State
The host has written
‘0’ to the MCR0 bit in
CONFIG, requesting
the CC to leave the
Configuration State
Delay
configured by
the DCR in
microticks
1001 microseconds
4000
microticks
delay
CC starts
entering the
Normal State
Programmed Delay
Startup
Note:
1 For a 40.000 MHz crystal connected to
EXTAL/XTAL pins, or for 40.000 MHz CC_CLK
input clock.
Time
Figure 3-148. Timing Diagram of CC State Transition from Configuration State to Normal State
3.9.3
Diagnosis Stop State
Protocol Operation Control: Freeze state.
The diagnosis stop state is intended to support the user during host software off-line system diagnosis. It
allows:
• the user to stop all protocol engine operations (frame transmission, reception, clock
synchronization, etc.) except host interface operations,
• the host to read all host interface registers.
In the diagnosis stop state:
• All operations of the protocol state machine are stopped.
• There is no transmission and no reception on the FlexRay bus.
• There is no clock synchronization running.
• The host interface is operational.
• All registers have the same access scheme as they have in normal operation (see Table 3-16);
The CC enters the diagnosis stop state from the normal state of operation:
• If the host sets the DIAGSTOP bit in the MCR0 register (see Section 3.2.3.2.1, “Module
Configuration Register 0 (MCR0)”).
MFR4200 Data Sheet, Rev. 0
200
Freescale Semiconductor
Communication Controller States
NOTE
The CC enters the diagnosis stop state immediately the DIAGSTOP bit is
set. This may cause a protocol violation; the user must ensure that entry to
the diagnosis stop state does not cause a protocol violation.
The CC exits from the diagnosis stop state and enters the configuration state (see Section 3.9.2,
“Configuration State”).
3.9.4
Normal Active State
Protocol Operation Control: Normal active state.
In the normal state, the CC supports regular communication functions — frame transmission, reception,
clock synchronization, host interface operations, etc.
In the normal state:
•
•
•
•
The CC performs transmission and reception on the FlexRay bus, if configured.
Clock synchronization runs.
The host interface is operational.
All registers comply with the access scheme shown in Table 3-16.
The CC enters the normal state from the configuration state:
• If the host clears the CONFIG bit in the MCR0 register to ‘0’ (see Section 3.2.3.2.1, “Module
Configuration Register 0 (MCR0)”).
The CC exits the normal state and enters:
• The configuration state, according to the state of the CONFIG bit in the MCR0 register
• The diagnosis stop state, according to the state of the DIAGSTOP bit in the MCR0 register.
• The debug state, according to the state of the DBG bit in the MCR0 register.
• The listen only state, according to the state of the LO bit in the MCR0 register.
• The listen only state, to deal with errors caused by clock synchronization failure (for more detailed
information, refer to the PWD: Clock Synchronization chapter).
• The sleep state, according to the state of the SLPRQ and SLPACK bits in the MCR0 register.
For the description of the SLPRQ, SLPACK, CONFIG, DIAGSTOP, DBG and LO bits, see
Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”.
NOTE
For a detailed description of the normal state, refer to the PWD: HW States
and Operation Modes chapter.
3.9.5
Normal Passive State
Protocol Operation Control: Normal passive state.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
201
MFR4200 FlexRay Communication Controller
In the normal passive state, the CC supports regular communication functions (reception, clock
synchronization, host interface operations, etc.), except frame transmission.
In the normal passive state:
• The CC receives frames on the FlexRay bus, if configured.
• The CC does not transmit any frames on the FlexRay bus.
• Clock synchronization runs.
• The host interface is operational.
• All registers comply with the access scheme shown in Table 3-16.
The CC enters the normal passive state from the normal mode of operation:
• From the normal active state, if the clock synchronization failed (for more detailed information,
refer to the PWD: Clock Synchronization chapter)
NOTE
The CC enters the normal passive state at the end of the current
communication cycle.
The CC exits the normal passive state and enters:
• The configuration state, according to the state of the CONFIG bit in the MCR0 register;
• The diagnosis stop state, according to the state of the DIAGSTOP bit in the MCR0 register;
• The debug state, according to the state of the DBG bit in the MCR0 register;
• The sleep state, according to the state of the SLPRQ and SLPACK bits in the MCR0 register; (see
Section 3.2.3.2.1, “Module Configuration Register 0 (MCR0)”).
NOTE
For a detailed description of the listen state, refer to the PWD: HW States
and Operation Modes chapter.
3.10
3.10.1
Debug Port
Debug Port Overview
The debug port is provided by means of two MFR4200 pins — BGT/DBG2/IF_SEL0 and
ARM/DBG1/CLK_S0. The debug port control register (see Section 3.2.3.3.33, “Debug Port Control
Register (DBPCR)”) selects the output functions for these two pins. The functions are controlled
independently of each other and, therefore, the same or different output functions may be configured for
the BGT/DBG2/IF_SEL0 and ARM/DBG1/CLK_S0 pins.
NOTE
As the DBG1 and DBG2 signals are shared with the bus guardian output
signals on the BGT/DBG2/IF_SEL0 and ARM/DBG1/CLK pins, the debug
port pins are not accessible in applications where bus guardian devices are
connected to the MFR4200.
MFR4200 Data Sheet, Rev. 0
202
Freescale Semiconductor
Debug Port
3.10.2
Debug Port Functions
Table 3-23 describes all debug port functions.
Table 3-23. Debug Port Functions Description
Function
Short
Name
Indicated by
Description
Protocol state change
PCS
Rising edge of the signal
The CC strobes every protocol state change
(see Section 3.2.3.4.1, “Protocol State Register
(PSR)”).
Slot start in static segment
SSS
Rising edge of the signal
The CC strobes every static slot start.
Minislot start
MSS
Rising edge of the signal
The CC strobes every minislot start.
—
This function outputs data received on channel
A RxD (RXD_BG1/RXD1_485 pin) after glitch
filter processing.
RxD after glitch filter on channel
A
RAGFA
Dynamic slot start on channel A
DSSA
Rising edge of the signal
The CC strobes every dynamic slot start on
channel A.
SFA
Rising edge of the signal
The CC strobes every receive frame start on
channel A.
Received syntactically correct
an semantically valid frame
indication on channel A
RCFA
Rising edge of the signal
The CC indicates every reception of a
syntactically correct and semantically valid
frame on channel A after 11 FlexRay bus bits,
measured from the received frame end
sequence.
Start of a communication cycle
SCC
Rising edge of the signal and its The CC strobes every communication cycle
level
start with a rising edge. This signal stays high
during the communication cycle and the CC
negates it (low) with the NIT start.
Macrotick
MTS
Rising edge of the signal
This function outputs the CC internal corrected
macrotick.
Start of offset correction
SOC
Rising edge of the signal
The CC strobes the time point during the NIT
when it performs the offset correction.
—
This function outputs data received on channel
B RxD (RXD_BG2/RXD2_485 pin) after glitch
filter processing.
Start of frame on channel A
RxD after glitch filter on channel
B
RAGFB
Dynamic slot start on channel B
DSSB
Rising edge of the signal
The CC strobes every dynamic slot start on
channel B.
SFB
Rising edge of the signal
The CC strobes every receive frame start on
channel B.
RCFB
Rising edge of the signal
The CC indicates every reception of a
syntactically correct and semantically valid
frame on channel B after 11 FlexRay bus bits
measured from the received frame end
sequence.
Start of frame on channel B
Received syntactically correct
an semantically valid frame
indication on channel B
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
203
MFR4200 FlexRay Communication Controller
3.10.3
Debug Port Function Timing
Figure 3-149 depicts a timing diagram for the start of communication cycle function and the start of offset
correction function, in relation to the communication cycle timing.
Communication
cycle
NIT
Static
Segment
Dynamic
Segement
Symbol
Window
NIT
Static
Segment
Start of
communication
cycle
Start of
offset correction
Figure 3-149. Start of Communication Cycle and Start of Offset Correction Functions Timing
The following debug functions indicate certain events with the rising edge and stay high for three clock
cycles of the EXTAL or CC_CLK clock (see Figure 3-150).
• Protocol state change
• Minislot start
• RxD after glitch filter on channel A
• Dynamic slot start on channel A
• Start of frame on channel A
• Indication of syntactically correct and semantically valid frame received on channel A
• Macrotick
• RxD after glitch filter on channel B
• Dynamic slot start on channel B
• Start of frame on channel B
• Indication of syntactically correct and semantically valid frame received on channel B
EXTAL or
CC_CLK
Debug port
signal
Figure 3-150. Timing for Debug Functions with Three EXTAL or CC_CLK Clock Cycles of High State
(Logic “1“)
MFR4200 Data Sheet, Rev. 0
204
Freescale Semiconductor
Debug Port
The slot start in static segment debug function indicates every slot start event in the static segment with a
rising edge that stays high for one clock cycle of the EXTAL or CC_CLK clock (see Figure 3-151):
EXTAL or
CC_CLK
Debug port
signal
Figure 3-151. Slot Start in Static Segment Function Timing
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
205
MFR4200 FlexRay Communication Controller
MFR4200 Data Sheet, Rev. 0
206
Freescale Semiconductor
Chapter 4
Dual Output Voltage Regulator (VREG3V3V2)
4.1
Introduction
The VREG3V3V2 is a dual output voltage regulator providing two separate 2.5 V (typical) supplies
differing in the amount of current that can be sourced. The regulator input voltage range is from 3.3 V up
to 5 V (typical).
4.1.1
Features
The block VREG3V3V2 includes these distinctive features:
• Two parallel, linear voltage regulators
— Bandgap reference
• Power-on reset (POR)
• Low-voltage reset (LVR)
4.1.2
Modes of Operation
VREG3V3V2 can operate in two modes on MFR4200:
• Full-performance mode (FPM)
The regulator is active, providing the nominal supply voltage of 2.5 V with full current sourcing
capability at both outputs. Features LVR (low-voltage reset) and POR (power-on reset) are
available.
• Shutdown mode
Controlled by VREGEN (see device overview chapter for connectivity of VREGEN).
This mode is characterized by minimum power consumption. The regulator outputs are in a high
impedance state; only the POR feature is available, and LVR is disabled.
This mode must be used to disable the chip internal regulator VREG3V3V2, i.e., to bypass the
VREG3V3V2 to use external supplies.
4.1.3
Block Diagram
Figure 4-1 shows the function principle of VREG3V3V2 by means of a block diagram. The regulator core
REG consists of two parallel sub-blocks, REG1 and REG2, providing two independent output voltages.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
207
Dual Output Voltage Regulator (VREG3V3V2)
VDDOSC
REG2
VDDR
VSSOSC
REG
VSSR
VDDA
VSSA
VDD
REG1
LVR
LVR
POR
POR
VSS
VREGEN
CTRL
REG: Regulator Core
CTRL: Regulator Control
LVR: Low Voltage Reset
POR: Power-on Reset
PIN
Figure 4-1. VREG3V3 Block Diagram
MFR4200 Data Sheet, Rev. 0
208
Freescale Semiconductor
Dual Output Voltage Regulator (VREG3V3V2)
4.2
External Signal Description
Due to the nature of VREG3V3V2 being a voltage regulator providing the chip internal power supply
voltages most signals are power supply signals connected to pads.
Table 4-1 shows all signals of VREG3V3V2 associated with pins.
Table 4-1. VREG3V3V2 — Signal Properties
Name
Port
VDDR
—
VSSR
Function
Reset State
Pull Up
VREG3V3V2 power input (positive supply)
—
—
—
VREG3V3V2 power input (ground)
—
—
VDDA
—
VREG3V3V2 quiet input (positive supply)
—
—
VSSA
—
VREG3V3V2 quiet input (ground)
—
—
VDD
—
VREG3V3V2 primary output (positive supply)
—
—
VSS
—
VREG3V3V2 primary output (ground)
—
—
VDDOSC
—
VREG3V3V2 secondary output (positive supply)
—
—
VSSOSC
—
VREG3V3V2 secondary output (ground)
—
—
VREGEN (optional)
—
VREG3V3V2 (Optional) Regulator Enable
—
—
NOTE
Check device overview chapter for connectivity of the signals.
4.2.1
VDDR, VSSR — Regulator Power Input
Signal VDDR is the power input of VREG3V3V2. All currents sourced into the regulator loads flow
through this pin. A chip external decoupling capacitor (100 nF...220 nF, X7R ceramic) between VDDR and
VSSR can smoothen ripple on VDDR.
For entering shutdown mode, pin VDDR must also be tied to ground on devices without a VREGEN pin.
4.2.2
VDDA, VSSA — Regulator Reference Supply
Signals VDDA/VSSA which are supposed to be relatively quiet are used to supply the analog parts of the
regulator. Internal precision reference circuits are supplied from these signals. A chip external decoupling
capacitor (100 nF...220 nF, X7R ceramic) between VDDA and VSSA can further improve the quality of this
supply.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
209
Dual Output Voltage Regulator (VREG3V3V2)
4.2.3
VDD, VSS — Regulator Output1 (Core Logic)
Signals VDD/VSS are the primary outputs of VREG3V3V2 that provide the power supply for the core
logic. These signals are connected to device pins to allow external decoupling capacitors (100 nF...220 nF,
X7R ceramic).
In shutdown mode an external supply at VDD/VSS can replace the voltage regulator.
4.2.4
VDDOSC, VSSOSC — Regulator Output2 (OSC)
Signals VDDOSC/VSSOSC are the secondary outputs of VREG3V3V2 that provide the power supply for the
oscillator. These signals are connected to device pins to allow external decoupling capacitors (100 nF...220
nF, X7R ceramic).
In shutdown mode an external supply at VDDOSC/VSSOSC can replace the voltage regulator.
4.2.5
VREGEN — Optional Regulator Enable
This optional signal is used to shutdown VREG3V3V2. In that case VDD/VSS and VDDOSC/VSSOSC must
be provided externally. shutdown mode is entered with VREGEN being low. If VREGEN is high, the
VREG3V3V2 is in reduced-power mode.
For the connectivity of VREGEN see device overview chapter.
NOTE
Switching from FPM or RPM to shutdown of VREG3V3V2 and vice versa
is not supported while the CC is powered.
4.3
Functional Description
Block VREG3V3V2 is a voltage regulator as depicted in Figure 4-1. The regulator functional elements are
the regulator core (REG), a power-on reset module (POR) and a low-voltage reset module (LVR). There
is also the regulator control block (CTRL) which manages the operating modes of VREG3V3V2.
4.3.1
REG — Regulator Core
VREG3V3V2, respectively its regulator core has two parallel, independent regulation loops (REG1 and
REG2) that differ only in the amount of current that can be sourced to the connected loads. Therefore, only
REG1 providing the supply at VDD/VSS is explained. The principle is also valid for REG2.
The regulator is a linear series regulator with a bandgap reference in its full-performance mode and a
voltage clamp in reduced-power mode. All load currents flow from input VDDR to VSS or VSSOSC, the
reference circuits are connected to VDDA and VSSA.
4.3.2
Full-performance Mode
In full-performance mode, a fraction of the output voltage (VDD) and the bandgap reference voltage are
fed to an operational amplifier. The amplified input voltage difference controls the gate of an output driver.
MFR4200 Data Sheet, Rev. 0
210
Freescale Semiconductor
Dual Output Voltage Regulator (VREG3V3V2)
4.3.3
POR — Power On Reset
This functional block monitors output VDD. If VDD is below VPORD, signal POR is high; if it exceeds
VPORD, the signal goes low. The transition to low forces the CPU into the power-on sequence.
Due to its role during chip power-up, this module must be active in all operating modes of VREG3V3V2.
4.3.4
LVR — Low Voltage Reset
Block LVR monitors the primary output voltage VDD. If it drops below the assertion level (VLVRA) signal
LVR asserts and when rising above the deassertion level (VLVRD) signal LVR negates again. The LVR
function is available only in full-performance mode.
4.3.5
CTRL — Regulator Control
This part contains digital functionality needed to control the operating modes.
4.4
Resets
This subsection describes how VREG3V3V2 controls the reset of the CC. The reset values of registers and
signals are provided in Section 3.2, “Memory Map and Registers”. Possible reset sources are listed in
Table 4-2.
Table 4-2. VREG3V3V2 — Reset Sources
Reset Source
4.4.1
Local Enable
Power-on reset
Always active
Low-voltage reset
Always active
Power On Reset
During chip power-up the digital core may not work if its supply voltage VDD is below the POR
deassertion level (VPORD). Therefore, signal POR, which forces the other blocks of the device into reset,
is kept high until VDD exceeds VPORD. Then POR becomes low and the reset generator of the device
continues the start-up sequence.
4.4.2
Low Voltage Reset
For information on low-voltage reset see Section 4.3.4, “LVR — Low Voltage Reset”.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
211
Dual Output Voltage Regulator (VREG3V3V2)
MFR4200 Data Sheet, Rev. 0
212
Freescale Semiconductor
Chapter 5
Clocks and Reset Generator
5.1
Introduction
This document describes the CRG operation in functional mode and only those aspects of it useful to the
end user.
5.1.1
Features
The main features of this block are:
• System clock generator depending on the mode: functional, scan or memory BIST mode.
• System reset generation from the following possible events:
— Power-on
— Low voltage
— External pin reset
• Reset control signal generation for the FlexRay module’s CLKOUT generator.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
213
Clocks and Reset Generator
5.2
5.2.1
Functional Description
MFR4200 Pins Relevant to the CRG
Table 5-1. MFR4200 Pins Relevant to the CRG
Pin N
Pin Name
In/Out
Pin type1
1
TEST
I
-
This pin must be tied to logic ‘0’.
16
RESET#
I
-
Hardware reset input
24
EXTAL/CC_CLK
I
-
Crystal driver / External clock pin
25
XTAL
I
-
Crystal driver pin
32
BGT/DBG2/IF_SEL0
I/O
DC/PD
Bus guardian tick / Debug strobe point signal 2 / Host interface
selection 0
41
TXD_BG1/TXD1_485/
IF_SEL1
I/O
DC/PD
PHY data transmitter output / RS485 data transmitter output /
Host interface selection 1
47
ARM/DBG1/CLK_S0
I/O
DC/PD
Bus guardian ARM signal / Debug strobe point signal 1 /
Controller clock output select signal 0
48
MT/CLK_S1
I/O
DC/PD
Bus guardian macrotick / Controller clock output select signal 1
52
ECLK_CC
I
PC
HCS12 clock input
63
CLKOUT
I/O
DC
CLKOUT output, selectable as disabled or 4/10/40 MHz.
Functional Description
1
PC (Pullup/down Controlled) – Register controlled internal weak pull up/down for a pin in the input mode.
PD (Pull Down) – Internal weak pull down for a pin in the input mode.
DC (Drive strength Controlled) – Register controlled drive strength for a pin in the output mode.
Z – Three-stated pin.
OD (Open Drain) – Output pin with open drain.
Reset state:
– All pins with the PC option have pullup/down resistors disabled.
– All pins with the DC option have full drive strength.
5.2.2
Reset Generation and CLKOUT Control
The CRG will provide a system reset on any of the following events: power-on, low voltage, or low level
detected at the RESET# pin. Entry into reset is asynchronous and does not require a clock; however, the
MFR4200 cannot sequence out of reset in functional mode without a system clock.
The CRG scans, during different periods depending on the origin of the reset source, the interface and
CLKOUT selector pins: IF_SEL[0:1] and CLK_S[0:1].
MFR4200 Data Sheet, Rev. 0
214
Freescale Semiconductor
Functional Description
NOTE
See Section 3.7, “Host Controller Interfaces” and Section 3.8, “External
4/10 MHz Output Clock” for a description of the encoding of these pins.
5.2.2.1
Power-on or Low Voltage Reset
When the power-on or low voltage reset signals are asserted, the CRG sets the internal reset signal. The
CRG will negate synchronously the internal reset signal, approximately 16000 EXTAL/CC_CLK clock
ticks after the negation of the power-on or low-voltage reset signals.
While the internal reset signal is asserted due to a power-on or low-voltage situation, the pins CLK_S[0:1]
and IF_SEL[0:1] are latched and the CLKOUT is disabled. After the CRG negates the internal reset signal
the FlexRay core will:
1. generate CLKOUT signal with frequency indicated by the values latched in CLK_S[0:1],
2. select the required host interface with the last value latched in IF_SEL[0:1] signals.
VDD
VDD
power_on reset
power_on
reset
internal_reset
internal_reset
~16000
~16000
latching
window
latching window
CLK_Sx
IF_SELx
CLK_Sx – -IF_SELx
CLKOUT
CLKOUT
Figure 5-1. Power-on Reset
low_voltage
low_voltage
internal_reset
internal_reset
~16000
~
16000
latching
window
latching
CLK_Sx
IF_SELx
CLK_Sx –- IF_SELx
CLKOUT
CLKOUT
low_level_voltage
Figure 5-2. Low Voltage Reset
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
215
Clocks and Reset Generator
5.2.2.2
External Reset
When the RESET# pin is asserted the CRG sets the internal reset signal. The CRG will negate the internal
reset signal approximately 16 EXTAL/CC_CLK clock ticks after the de-assertion of RESET#.
While the internal reset signal is asserted due to an external reset, the pins CLK_S[0:1] and IF_SEL[0:1]
are latched but the CLKOUT signal is still be generated. Figure 5-3 shows an external reset sequence.
RESET#
RESET#
RESET
~~16
16
internal_reset
internal_reset
latching
latching
window
CLK_Sx
IF_SELx
CLK_Sx –- IF_SELx
CLKOUT
CLKOUT
Figure 5-3. External Reset
MFR4200 Data Sheet, Rev. 0
216
Freescale Semiconductor
Chapter 6
Oscillator (OSCV2)
6.1
Introduction
The OSCV2 module provides one oscillator concept:
• A robust full swing Pierce oscillator with the possibility to feed in an external square wave
6.1.1
Features
The Pierce OSC option provides the following features:
• Wider high frequency operation range
• No DC voltage applied across the crystal
• Full rail-to-rail (2.5 V nominal) swing oscillation with low EM susceptibility
• Fast startup
Common features:
• Operation from the VDDOSC 2.5 V (nominal) supply rail
6.1.2
Modes of Operation
One mode of operation exists:
• Full swing Pierce oscillator mode, which can also be used to feed in an externally generated square
wave suitable for high frequency operation and harsh environments
6.2
External Signal Description
This section lists and describes the signals that connect off chip.
6.2.1
VDDOSC and VSSOSC — OSC Operating Voltage, OSC Ground
These pins provide the operating voltage (VDDOSC) and ground (VSSOSC) for the OSCV2 circuitry. This
allows the supply voltage to the OSCV2 to be independently bypassed.
6.2.2
EXTAL and XTAL — Clock/Crystal Source Pins
These pins provide the interface for either a crystal or a CMOS compatible clock to control the internal
clock generator circuitry. EXTAL is the external clock input or the input to the crystal oscillator amplifier.
XTAL is the output of the crystal oscillator amplifier. All the CC internal system clocks are derived from
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
217
Oscillator (OSCV2)
the EXTAL input frequency. In full stop mode (PSTP = 0) the EXTAL pin is pulled down by an internal
resistor of typical 200 kΩ.
NOTE
Freescale Semiconductor recommends an evaluation of the application
board and chosen resonator or crystal by the resonator or crystal supplier.
The Crystal circuit is changed from standard.
The Pierce circuit is not suited for overtone resonators and crystals without
a careful component selection.
For more information on EXTAL and XTAL, see Section 2.2.3.22, “XTAL
— Crystal Driver Pin”.
6.3
Functional Description
The OSCV2 block has two external pins, EXTAL and XTAL. The oscillator input pin, EXTAL, is intended
to be connected to either a crystal or an external clock source.
A buffered EXTAL signal, OSCCLK, becomes the internal reference clock. To improve noise immunity,
the oscillator is powered by the VDDOSC and VSSOSC power supply pins.
MFR4200 Data Sheet, Rev. 0
218
Freescale Semiconductor
Appendix A
Electrical Characteristics
A.1
General
NOTE
The electrical characteristics given in this appendix are preliminary and
must be used as a guide only. Values cannot be guaranteed by Freescale and
are subject to change without notice.
NOTE
The part is specified and tested over the 5 V and 3.3 V ranges. For the
intermediate range, generally the electrical specifications for the 3.3 V
range apply, but the part is not tested in production test in the intermediate
range.
This appendix provides the most accurate electrical information for the MFR4200 device available at the
time of publication.
This introduction is intended to give an overview on several common topics like power supply, current
injection etc.
A.1.1
Parameter Classification
The electrical parameters shown in this supplement are guaranteed by various methods. The following
classifications are used and the parameters are tagged accordingly in the column labeled “C” in the
parameter tables, where appropriate.
P:
Parameters that are guaranteed during production testing on each individual device.
C:
Parameters that are achieved by the design characterization by measuring a statistically relevant
sample size across process variations.
T:
Parameters that are achieved by design characterization on a small sample size from typical
devices under typical conditions unless otherwise noted. All values shown in the typical column
are within this category.
D:
Parameters that are derived mainly from simulations.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
219
Electrical Characteristics
A.1.2
Power Supply
The MFR4200 uses several pins to supply power to the I/O pins, oscillator and the digital core.
The VDDA, VSSA pair supplies the internal voltage regulator.
The VDDX, VSSX, VDDR and VSSR pairs supply the I/O pins, VDDR supplies also the internal voltage
regulator.
VDD2_5 and VSS2_5 are the supply pins for the digital logic, VDDOSC, VSSOSC supply the oscillator.
VDDA, VDDX, VDDR as well as VSSA, VSSX, VSSR are connected by anti-parallel diodes for ESD
protection.
NOTE
In the following context, VDD5 is used for either VDDA, VDDR and
VDDX; VSS5 is used for either VSSA, VSSR and VSSX unless otherwise
noted.
IDD5 denotes the sum of the currents flowing into the VDDA, VDDX and
VDDR pins.
VDD is used for VDD2_5 and VDDOSC, VSS is used for VSS2_5 and
VSSOSC.
IDD is used for the current flowing into VDD2_5.
A.1.3
Pins
There are four groups of functional pins.
A.1.3.1
3.3V I/O pins
Those I/O pins have a nominal level of 3.3V. This class of pins is comprised of all I/O pins (all MFR4200
pins excluding EXTAL, XTAL and all power supply pins).The internal structure of all those pins is
identical, however some of the functionality may be disabled. E.g. for the input-only pins the output drivers
are disabled permanently.
A.1.3.2
Oscillator
The pins EXTAL, XTAL dedicated to the oscillator have a nominal 2.5V level. They are supplied by
VDDOSC.
A.1.3.3
VDDR
This pin is used to enable the on chip voltage regulator.
MFR4200 Data Sheet, Rev. 0
220
Freescale Semiconductor
General
A.1.4
Current Injection
Power supply must maintain regulation within operating VDD5 or VDD range during instantaneous and
operating maximum current conditions. If positive injection current (Vin > VDD5) is greater than IDD5, the
injection current may flow out of VDD5 and could result in external power supply going out of regulation.
Ensure external VDD5 load will shunt current greater than maximum injection current. This will be the
greatest risk when the CC is not consuming power; e.g. if no system clock is present, or if clock rate is very
low which would reduce overall power consumption.
A.1.5
Absolute Maximum Ratings
Absolute maximum ratings are stress ratings only. A functional operation under or outside those maxima
is not guaranteed. Stress beyond those limits may affect the reliability or cause permanent damage of the
device.
This device contains circuitry protecting against damage due to high static voltage or electrical fields;
however, it is advised that normal precautions be taken to avoid application of any voltages higher than
maximum-rated voltages to this high-impedance circuit. Reliability of operation is enhanced if unused
inputs are tied to an appropriate logic voltage level (e.g., either VSS5 or VDD5).
Table A-1. Absolute Maximum Ratings1
Num
Rating
Symbol
Min
Max
Unit
1
I/O, Regulator and Analog Supply Voltage
VDD5
-0.3
6.5
V
2
Digital Logic Supply Voltage 2
VDD
-0.3
3.0
V
VDDOSC
-0.3
3.0
V
2
3
Oscillator Supply Voltage
4
Voltage difference VDDX to VDDR and VDDA
∆VDDX
-0.3
0.3
V
5
Voltage difference VSSX to VSSR and VSSA
∆VSSX
-0.3
0.3
V
6
Digital I/O Input Voltage
VIN
-0.3
6.5
V
7
EXTAL, XTAL inputs
VILV
-0.3
3.0
V
8
Instantaneous Maximum Current
Single pin limit for all digital I/O pins 3
I
-25
+25
mA
9
Instantaneous Maximum Current
Single pin limit for EXTAL, XTAL4
IDL
-25
+25
mA
10
Operating Temperature Range (packaged)
TA
-40
+125
oC
11
Operating Temperature Range (junction)
TJ
-40
+150
oC
12
Storage Temperature Range
Tstg
– 65
155
°C
D
1
Beyond absolute maximum ratings device might be damaged.
The device contains an internal voltage regulator to generate the logic and OSC supply out of the I/O supply. The
absolute maximum ratings apply when the device is powered from an external source.
3 All digital I/O pins are internally clamped to V
SSX and VDDX, VSSR and VDDR or VSSA and VDDA.
4 Those pins are internally clamped to V
SSOSC and VDDOSC.
2
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
221
Electrical Characteristics
A.1.6
ESD Protection and Latch-up Immunity
All ESD testing is in conformity with CDF-AEC-Q100 Stress test qualification for Automotive Grade
Integrated Circuits. During the device qualification ESD stresses were performed for the Human Body
Model (HBM), the Machine Model (MM) and the Charge Device Model.
A device will be defined as a failure if after exposure to ESD pulses the device no longer meets the device
specification. Complete DC parametric and functional testing is performed per the applicable device
specification at room temperature followed by hot temperature, unless specified otherwise in the device
specification.
Table A-2. ESD and Latch-up Test Conditions
Model
Human Body
Machine
Latch-up
Description
Symbol
Value
Unit
Series Resistance
R1
1500
Ohm
Storage Capacitance
C
100
pF
Number of Pulse per pin
positive
negative
-
3
3
Series Resistance
R1
0
Ohm
Storage Capacitance
C
200
pF
Number of Pulse per pin
positive
negative
-
3
3
Minimum input voltage limit
-
-2.5
V
Maximum input voltage limit
-
7.5
V
Table A-3. ESD and Latch-up Protection Characteristics
Num C
Rating
Symbol
Min
Max
Unit
1
T Human Body Model (HBM)
VHBM
2000
-
V
2
T Machine Model (MM)
VMM
200
-
V
3
T Charge Device Model (CDM)
VCDM
500
-
V
4
T Latch-up Current at TA = 125°C
positive
negative
ILAT
+100
-100
-
T Latch-up Current at TA = 27°C
positive
negative
ILAT
5
mA
-
mA
+200
-200
MFR4200 Data Sheet, Rev. 0
222
Freescale Semiconductor
General
A.1.7
Operating Conditions
This chapter describes the operating conditions of the device. Unless otherwise noted those conditions
apply to all the following data.
NOTE
Refer to the temperature rating of the device (C, V, M) with regards to the
ambient temperature TA and the junction temperature TJ. For power
dissipation calculations refer to Section A.1.8, “Power Dissipation and
Thermal Characteristics”.
Table A-4. Operating Conditions
Rating
Oscillator and Quartz frequency
Symbol
Min
Typ
Max
Unit
fOSC
-
40.000
40.000
MHz
Quartz overtone
Fundamental Frequency
Quartz frequency stability at TJ
fSTB
-1500
300
1500
ppm
Voltage difference VDDX to VDDR and VDDA
DVDDX
-0.1
0
0.1
V
Voltage difference VSSX to VSSR and VSSA
DVSSX
-0.1
0
0.1
V
I/O, Regulator and Analog Supply
VDD5
2.97
3.3
5.5
V
VDD
2.25
2.5
2.75
V
VDDOSC
2.25
2.5
2.75
V
Digital Logic Supply
Voltage1
Oscillator Supply Voltage1
Operating Junction Temperature Range
TJ
-40
-
140
oC
Operating Ambient Temperature Range2
TJ
-40
27
125
oC
1
2
The device contains an internal voltage regulator to generate the logic and OSC supply out of the I/O supply.
Refer to Section A.1.8, “Power Dissipation and Thermal Characteristics” for more information about the relation between
ambient temperature TA and device junction temperature TJ.
A.1.8
Power Dissipation and Thermal Characteristics
Power dissipation and thermal characteristics are closely related. The user must assure that the maximum
operating junction temperature is not exceeded. The average chip-junction temperature (TJ) in °C can be
obtained from:
T J = T A + ( P D • Θ JA )
Eqn. A-1
TJ = Junction Temperature [°C]
TA = Ambient Temperature [°C]
PD = Total Chip Power Dissipation [W]
ΘJA = Package Thermal Resistance [°C/W]
The total power dissipation can be calculated from:
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
223
Electrical Characteristics
P D = P INT + P IO
Eqn. A-2
PINT = Chip Internal Power Dissipation [W]
Two cases with internal voltage regulator enabled and disabled must be considered:
1. Internal Voltage Regulator disabled
P INT = I DD ⋅ V DD + I DDOSC ⋅ V DDOSC + I DDA ⋅ V DDA
P IO =
∑
R DSON ⋅ I IO
i
Eqn. A-3
2
Eqn. A-4
i
PIO is the sum of all output currents on I/O ports associated with VDDX and VDDR.
For RDSON is valid:
V OL
R DSON = ------------ ;
I OL
for outputs driven low
Eqn. A-5
respectively
V DD5 – V OH
R DSON = ------------------------------------ ; for outputs driven high
I OH
Eqn. A-6
2. Internal voltage regulator enabled
P
INT
= I
DDR
⋅V
DDR
+I
DDA
⋅V
Eqn. A-7
DDA
IDDR is the current shown in Table A-8 and not the overall current flowing into VDDR, which
additionally contains the current flowing into the external loads with output high.
P IO =
∑ RDSON ⋅ IIOi
2
Eqn. A-8
i
PIO is the sum of all output currents on I/O ports associated with VDDX and VDDR.
MFR4200 Data Sheet, Rev. 0
224
Freescale Semiconductor
General
Table A-5. Thermal Package Simulation Details
Num
1
2
3
4
5
6
Rating
Symbol
Value
Unit
1
Junction to Ambient LQFP64, single sided PCB1,2, Natural Convection
RθJA
67
o
C/W
2
Junction to Ambient LQFP64, double sided PCB with 2 internal planes1,3, Natural
Convection
RθJMA
52
o
C/W
3
Junction to Ambient LQFP64 (@200 ft/min), single sided PCB1,3
RθJMA
60
o
C/W
RθJMA
48
o
C/W
4
Junction to Ambient LQFP64 (@200 ft/min), double sided PCB with 2 internal
planes1,3
5
Junction to Board LQFP644
RθJB
34
o
C/W
6
Junction to Case LQFP645
RθJC
17
o
C/W
7
Junction to Package Top LQFP646, Natural Convection
ΨJT
3
o
C/W
Junction temperature is a function of die size, on-chip power dissipation, package thermal resistance, mounting site (board)
temperature, ambient temperature, air flow, power dissipation of other components on the board, and board thermal
resistance.
Per SEMI G38-87 and EIA/JEDEC Standard 51-2 with the single layer horizontal PC Board according to EIA/JEDEC Standard
51-3
Per EIA/JEDEC Standard 51-6 with the four layer horizontal PC Board (double-sided PCB with two internal planes) according
to EIA/JEDEC Standard 51-7
Thermal resistance between the die and the printed circuit board per EIA/JEDEC Standard 51-8. Board temperature is
measured on the top surface of the board near the package.
Thermal resistance between the die and the case top surface as measured by the cold plate method (MIL SPEC-883 Method
1012.1).
Thermal characterization parameter indicating the temperature difference between package top and the junction temperature
per EIA/JEDEC Standard 51-2.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
225
Electrical Characteristics
A.1.9
I/O Characteristics
This section describes the characteristics of all 3.3V I/O pins. All parameters are not always applicable,
e.g. not all pins feature pullup/pulldown resistances.
Table A-6. 5V I/O Characteristics (VDD5 = 5V)
Conditions are shown in Figure A-4, unless otherwise noted.
Num
C
1
P
Symbol
Min
Typ
Max
Unit
Input High Voltage
VIH
0.65*VDD5
-
-
V
T
Input High Voltage
VIH
-
-
VDD5+0.3
V
P
Input Low Voltage
VIL
-
-
0.35*VDD5
V
T
Input Low Voltage
VIL
VSS5-0.3
-
-
V
3
C
Input Hysteresis
VHYS
-
250
-
mV
4
P
High Impedance (Off-state) Leakage Current
VIN=VDD or VSS, all input/output and output pins
IIN
-2.5
-
+2.5
uA
5
P
Output High Voltage (pins in output mode)
@50% Partial Drive IOH = -2mA
VOH
VDD5-0.8
-
-
V
6
P
Output High Voltage (pins in output mode)
@100% Full Drive IOH = -10mA
VOH
VDD5-0.8
-
-
V
7
P
Output Low Voltage (pins in output mode)
@50% Partial Drive IOL = +2mA
VOL
-
-
0.8
V
8
P
Output Low Voltage (pins in output mode)
@100% Full Drive IOL = +10mA
VOL
-
-
0.8
V
9
P
Internal Pullup Device Current,
tested at VIL Max
IPUL
-
-
-130
uA
10
P
Internal Pullup Device Current,
tested at VIH Min.
IPUH
-10
-
-
uA
11
P
Internal Pulldown Device Current,
tested at VIH Min.
IPDH
-
-
130
uA
12
P
Internal Pulldown Device Current,
tested at VIL Max
IPDL
10
-
-
uA
13
d
Input Capacitance (input, input/output
pins)
CIN
-
7
-
pF
14
T
Injection Current1
2
15
1
P
Rating
mA
Single Pin Limit
IICS
-2.5
-
2.5
Total Device Limit. Sum of all injected currents
IICP
-25
-
25
Load Capacitance
50% Partial Drive
100% Full Drive
CL
-
-
pF
25
50
Refer to Section A.1.4, “Current Injection”, for more information.
MFR4200 Data Sheet, Rev. 0
226
Freescale Semiconductor
General
Table A-7. 3.3V I/O Characteristics (VDD5 = 3.3V)
Conditions are VDDX=3.3V +/-10% Temperature from -40oC to +140oC, unless otherwise noted
Num
C
1
P
Symbol
Min
Typ
Max
Unit
Input High Voltage
VIH
0.65*VDD5
-
-
V
T
Input High Voltage
VIH
-
-
VDD5+0.3
V
P
Input Low Voltage
VIL
-
-
0.35*VDD5
V
T
Input Low Voltage
VIL
VSS5-0.3
-
-
V
3
C
Input Hysteresis
VHYS
-
250
-
mV
4
P
High Impedance (Off-state) Leakage Current
VIN=VDD or VSS, all input/output and output pins
IIN
-2.5
-
+2.5
uA
5
P
Output High Voltage (pins in output mode)
@50% Partial Drive IOH = -0.75mA
VOH
VDD5-0.4
-
-
V
6
P
Output High Voltage (pins in output mode)
@100% Full Drive IOH = -4.5mA
VOH
VDD5-0.4
-
-
V
7
P
Output Low Voltage (pins in output mode)
@50% Partial Drive IOL = +0.9mA
VOL
-
-
0.4
V
8
P
Output Low Voltage (pins in output mode)
@100% Full Drive IOL = +5.5mA
VOL
-
-
0.4
V
9
P
Internal Pullup Device Current,
tested at VIL Max
IPUL
-
-
-60
uA
10
P
Internal Pullup Device Current,
tested at VIH Min.
IPUH
-6
-
-
uA
11
P
Internal Pulldown Device Current,
tested at VIH Min.
IPDH
-
-
60
uA
12
P
Internal Pulldown Device Current,
tested at VIL Max
IPDL
6
-
-
uA
13
D
Input Capacitance (input, input/output
pins)
CIN
-
7
-
pF
14
T
Injection Current1
2
15
1
P
Rating
mA
Single Pin Limit
IICS
-2.5
-
2.5
Total Device Limit. Sum of all injected currents
IICP
-25
-
25
Load Capacitance
50% Partial Drive
100% Full Drive
CL
-
-
pF
25
50
Refer to Section A.1.4, “Current Injection” for more information.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
227
Electrical Characteristics
A.1.10
Supply Currents
This section describes the current consumption characteristics of the device as well as the conditions for
the measurements.
A.1.10.1
Measurement Conditions
All measurements are without output loads. Unless otherwise noted the currents are measured with internal
voltage regulator enabled and a 40 MHz oscillator in standard Pierce mode. Production testing is
performed using a square wave signal at the EXTAL input.
Table A-8. Supply Current Characteristics
Conditions are shown in Table A-4 unless otherwise noted
Num C
1
Rating
P Run supply currents
Internal regulator enabled
Symbol
Min
Typ
Max
Unit
IDD5
-
-
49.901
mA
25°C
-
-
50.563
70°C
-
-
TBD
85°C
-
-
TBD
100°C
-
-
TBD
105°C
-
-
TBD
120°C
-
-
TBD
125°C
-
-
TBD
140°C
-
-
51.047
-40°C
MFR4200 Data Sheet, Rev. 0
228
Freescale Semiconductor
Voltage Regulator (VREG)
A.2
Voltage Regulator (VREG)
A.2.1
Operating Conditions
Table A-9. Voltage Regulator - Operating Conditions
Conditions are shown in Table A-4 unless otherwise noted
Num
C
1
P
Input Voltages
2
P
Regulator Current
Shutdown Mode
3
P
4
5
6
P
P
C
Characteristic
Symbol
Min
Typical
Max
Unit
VVDDR,A
2.97
—
5.5
V
IREG
—
TBD
40
µA
Output Voltage Core
Full Performance Mode
Shutdown Mode
VDD
2.45
—
2.5
—1
2.75
—
V
V
Output Voltage OSC
Full Performance Mode
Shutdown Mode
VDDOSC
2.35
—
2.5
—2
2.75
—
V
V
Low Voltage Reset3
Assert Level
VLVRA
2.25
—
—
V
Power-on Reset4
Assert Level
Deassert Level
VPORA
VPORD
0.97
—
—
—
—
2.05
V
V
1
High Impedance Output
High Impedance Output
3 Monitors VDD, always active
4 Monitors VDD, always active
2
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
229
Electrical Characteristics
A.2.2
Chip Power-up and Voltage Drops
Voltage regulator sub modules POR (power-on reset) and LVR (low voltage reset) handle chip power-up
or drops of the supply voltage. Their function is described in Figure A-1.
V
VDD
VLVRD
VLVRA
VPORD
t
POR
LVR
Figure A-1. Voltage Regulator — Chip Power-up and Voltage Drops (not scaled)
A.2.3
Output Loads
A.2.3.1
Resistive Loads
On-chip voltage regulator intended to supply the internal logic and oscillator circuits allows no external
DC loads.
A.2.3.2
Capacitive Loads
The capacitive loads are specified in Figure A-10. Ceramic capacitors with X7R dielectricum are required
Table A-10. Voltage Regulator Recommended Capacitive Loads
Num
Characteristic
1
VDD external capacitive load
3
VDDOSC external capacitive load
Symbol
Min
Typical
Max
Unit
CDDext
200
440
12000
nF
CDDOSCext
90
220
5000
nF
MFR4200 Data Sheet, Rev. 0
230
Freescale Semiconductor
Reset and Oscillator
A.3
Reset and Oscillator
This section summarizes the electrical characteristics of the various startup scenarios for the Oscillator.
A.3.1
Startup
Table A-11 summarizes several startup characteristics explained in this section. Detailed description of the
startup behavior can be found in the MFR4200 Clock and Reset Generator (CRG) Block User Guide.
Table A-11. Startup Characteristics
Conditions are shown in Table A-4 unless otherwise noted
Num
C
Rating
Symbol
Min
Typ
Max
Unit
1
T POR release level
VPORR
-
-
2.07
V
2
T POR assert level
VPORA
0.97
-
-
V
3
D Reset input pulse width, minimum input time
PWRSTL
2
-
-
tosc
4
D Startup from external reset negation
nPSST
25
27
30
nosc
A.3.1.1
POR
The release level VPORR (see Table A-9) and the assert level VPORA (see Table A-9) are derived from the
VDD Supply. They are also valid if the device is powered externally. After releasing the POR reset the
oscillator is started. The fastest startup time possible is given by nuposc. There is no clock monitoring
function implemented.
A.3.1.2
LVR
The assert level VLVRA (see Table A-9) is derived from the VDD Supply. The fastest startup time possible
is given by nuposc. There is no clock monitoring function implemented.
A.3.1.3
External Reset
When external reset is asserted for a time greater than PWRSTL the CRG module generates an internal
reset, and the CC starts operations without doing a clock quality check, if there was an oscillation before
reset.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
231
Electrical Characteristics
A.3.2
Oscillator
The device features an internal Pierce oscillator. The device does not have a clock monitor.
Table A-12. Oscillator Characteristics
Conditions are shown in Table A-4 unless otherwise noted
Num C
1
Rating
Symbol
Min
Typ
Max
Unit
1
C Crystal oscillator range (Pierce) 1
fOSC
0.5
-
40
MHz
2
P Startup Current
iOSC
100
-
-
µA
3
C Oscillator start-up time
tUPOSC
-
-
TBD
ms
6
P External square wave input frequency
fEXT
0.5
-
50
MHz
7
D External square wave pulse width low
tEXTL
9.5
-
-
ns
8
D External square wave pulse width high
tEXTH
9.5
-
-
ns
9
D External square wave rise time
tEXTR
-
-
1
ns
10
D External square wave fall time
tEXTF
-
-
1
ns
11
D Input Capacitance (EXTAL, XTAL pins)
CIN
-
7
-
pF
12
C DC Operating Bias in Pierce mode on EXTAL Pin
VDCBIAS
-
TBD
-
V
Depending on the crystal a damping series resistor might be necessary
A.4
AMI Interface Timing Diagram
The CC AMI Interface read/write timing diagram is shown on the Figure A-2.
• Writing to the device is accomplished when Chip Enable(CE#) and Write Enable (WE#) inputs are
low (asserted).
• Reading from the device is accomplished when Chip Enable (CE#) and Output Enable (OE#) are
low (asserted) while the Write Enable (WE#) is high (negated).
• The input/output pins (D[15:0]) are in a high-impedance state when the device is not selected (CE#
is high), the outputs are disabled (OE# is high) or during a write operation (CE# is low, WE# is
low).
MFR4200 Data Sheet, Rev. 0
232
Freescale Semiconductor
AMI Interface Timing Diagram
tRC
tACE
tOEH
CE#
tSAR
A[9..1]
tHAR
ADDRESS valid
tDOE
tHOE
tLOE
OE#
tHZOE
tLZOE
D[15..0]
High-Z
DATA valid
High-Z
“1”
WE#
READ CYCLE
tWC
tSCE
tCEWE
CE#
tSAW
A[9..1]
tHAW
ADDRESS valid
tPWE
tWEH
WE#
High-Z
D[15..0]
High-Z
DATA valid
tSD
tHD
“1”
OE#
WRITE CYCLE
Figure A-2. AMI Interface Read and Write Timing Diagrams
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
233
Electrical Characteristics
tOEWE
CE#
A[9..1]
ADDRESS valid
ADDRESS valid
“1”
OE#
D[15..0]
High-Z
High-Z
DATA valid
WE#
DATA valid
HighZ
“1”
WRITE CYCLE
READ CYCLE
Figure A-3. AMI Interface Write-after-Read Transactions Timing Diagram
tWEOE
CE#
A[9..1]
ADDRESS valid
ADDRESS valid
“1”
WE#
D[15..0]
OE#
HighZ
DATA valid
High-Z
DATA valid
High-Z
“1”
WRITE CYCLE
READ CYCLE
Figure A-4. AMI Interface Read-after-Write Transactions Timing Diagram
MFR4200 Data Sheet, Rev. 0
234
Freescale Semiconductor
AMI Interface Timing Diagram
Table A-13. AMI Interface AC Switching Characteristics over the Operating Range
Characteristic
Symbol
Min
Max
Unit
Read Cycle
Read Time Cycle
tRC
155
-
ns
Address Setup Read
tSAR
5
-
ns
Address Hold Read
tHAR
50
-
ns
OE# LOW to Data valid
tDOE
-
145
ns
OE# high time
tHOE
30
-
ns
OE# low time
tLOE
150
-
ns
OE# LOW to Low-Z
tLZOE
20
-
ns
OE# HIGH to High-Z
tHZOE
-
15
ns
OE# HIGH to CE# HIGH
tOEH
0
-
ns
WE# HIGH to OE# LOW
tWEOE
80
-
ns
Write Cycle
Write Time Cycle
tWC
50
-
ns
Address Setup Write
tSAW
30
-
ns
Address Hold Write
tHAW
5
-
ns
CE# LOW to Write End
tSCE
50
-
ns
Data Set-up to Write End
tSD
30
-
ns
Data Hold from Write End
tHD
5
-
ns
WE# Pulse Width
tPWE
30
-
ns
WE# high time
tWEH
55
-
ns
Write End to CE# high
tCEWE
30
-
ns
OE# HIGH to WE# LOW
tOEWE
15
-
ns
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
235
Electrical Characteristics
A.5
HCS12 Interface Timing Diagram
The HCS12 device external bus is synchronous with clock frequency up to 8 MHz. Signals are sampled on
the both ECLK# edges (see Figure A-5).
The HCS12 host addresses the CC as a slow memory device. Due to that the HCS12 ECLK external clock
signal must be stretched. In the MFR4200 the output ECLK clock must be stretched by 3 periods of the
HCS12 internal bus-rate clock.
The CC HCS12 Interface read/write timing diagram is shown in Figure A-5.
For more information regarding the HCS12 and HCS12 programming, refer to the HCS12 V1.5 core user
guide, available at http://www.freescale.com/files/microcontrollers/doc/ref_manual/S12CPU15UG.pdf.
1
2
ECLK
3
(x)Addr/Data
(write)
data
4
5
(x)addr
7
6
data
8
9
R/W
10
(x)Addr/Data
(read)
11
data
12
13
(x)addr
14
15
data
ACS
ACS
20
21
22
LSTRB
Figure A-5. HCS12 Interface Read/write Timing Diagram
MFR4200 Data Sheet, Rev. 0
236
Freescale Semiconductor
HCS12 Interface Timing Diagram
Table A-14. HCS12 Interface Timing Parameters
Units
Restriction1
-
ns
CC
-
-
ns
CC
11
-
-
ns
HCS12
-
-
-
7
ns
HCS12
ECLK rise to write data invalid
3/CC_CLK
{75}-[4]
-
-
ns
CC
6(4)
Write data hold time
-
2
-
-
ns
HCS12
7
RW delay time
-
-
-
7
ns
HCS12
8
RW valid time to ECLK rise
-
14
-
-
ns
HCS12
9
RW hold time
-
2
-
-
ns
HCS12
10
Data hold to address
-
2
-
-
ns
HCS12
12
Multiplexed address hold time
-
2
-
-
ns
HCS12
13
ECLK high access time (ECLK
high to Read Data valid)
2/CC_CLK
{50}
3/CC_CLK
{75}
ns
CC
14
Read data setup time
-
13
-
-
ns
HCS12
15
Read data hold time
-
0
-
-
ns
HCS12
20
Low strobe delay time
-
-
-
7
ns
HCS12
21
Low strobe valid to ECLK rise
-
14
-
-
ns
HCS12
22
Low strobe hold time
-
2
-
-
ns
HCS12
Num
Rating
Min
Max
1
Pulse width, ECLK Low
1/CC_CLK
{25}2 3
-
2
Pulse width, ECLK High
4/CC_CLK
{100}+[14]
3,11
Address valid time to E rise4
-
4
Write data delay time
5
1
Column Restriction:
- CC limitation by the Communication Controller but complies to HCS12.
- HCS12 limitation because of HCS12 specification.
2 { .. } - values in ns if the CC_CLK = 40 MHz.
3 If the parameter is not met then ECLK signal deassertion cannot be sampled and the write/read window cannot be calculated.
4 (X)Addr and LSTRB are taken over by the controller with the rising edge of the ECLK.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
237
Electrical Characteristics
MFR4200 Data Sheet, Rev. 0
238
Freescale Semiconductor
64-pin LQFP package
Appendix B
Package Information
B.1
64-pin LQFP package
Figure B-1. 64-pin LQFP Mechanical Dimensions (Case N 840F-02) (Page 1)
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
239
Package Information
Figure B-2. 64-pin LQFP Mechanical Dimensions (Case N 840F-02) (Page 2)
MFR4200 Data Sheet, Rev. 0
240
Freescale Semiconductor
64-pin LQFP package
Figure B-3. 64-pin LQFP Mechanical Dimensions (Case N 840F-02) (Page 3)
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
241
Package Information
MFR4200 Data Sheet, Rev. 0
242
Freescale Semiconductor
64-pin LQFP package
Appendix C
Printed Circuit Board Layout Recommendations
The PCB must be laid out carefully to ensure proper operation of the voltage regulator and the CC. The
following rules must be observed:
• Every supply pair must be decoupled by a ceramic capacitor connected as near as possible to the
corresponding pins (Cd).
• The central point of the ground star should be the VSSR pin.
• Low-ohmic low-inductance connections should be used between VSSX and VSSR.
• VSSOSC must be directly connected to VSSR.
• Traces of VSSOSC, EXTAL and XTAL must be kept as short as possible. Occupied board area for
C1, C2, C3 and Q should be as small as possible.
• Other signals or supply lines should not be routed under the area occupied by C1, C2, C3, and Q
and the connection area of the CC.
• The central power input should be fed in at the VDDA/VSSA pins.
Figure C-1 shows a recommended PCB layout (64-pin LQFP) for standard Pierce oscillator mode, while
Table C-1 provides suggested values for the external components.
Table C-1. Suggested External Component Values
Component
Purpose
Type
Value
C1
OSC load cap
ceramic X7R
2pF
C2
OSC load cap
ceramic X7R
2pF
C3
VDDOSC filter cap
ceramic X7R
100– 220nF
C4
VDDA filter cap
ceramic X7R
100– 220nF
Cd
VDDR, VDDX filter cap
ceramic X7R/tantalum
100– 220nF
Cload
VDD2_5 filter cap
ceramic X7R
100– 220nF
RB
OSC res
1 MOhm
RS
OSC res
0 Ohm (i.e. short-circuit_
Q
Quartz
NDK NX8045GA
40 MHz
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
243
Printed Circuit Board Layout Recommendations
Figure C-1. Recommended PCB Layout (64-pin LQFP) for Standard Pierce Oscillator Mode
MFR4200 Data Sheet, Rev. 0
244
Freescale Semiconductor
Appendix C
MFR4200 Protocol Implementation Document
C.1
C.1.1
Introduction
Purpose
This document is an appendix to the MFR4200 FlexRay Microcontroller data sheet (MFR4200V2). It
describes the FlexRay protocol implementation in the MFR4200.
C.1.2
Structure
This appendix follows the structure of the FlexRay Communications System Protocol Specification V1.1
(PS V1.1). Each section explains whether the implementation in the MFR4200 is identical to the PS V1.1
or is realized with an intermediate solution. Where only the section headline is provided, the
implementation is compliant with the PS V1.1.
C.1.3
References
1. FlexRay Communications System Protocol Specification V1.1 (intermediate consortium baseline)
(PS V1.1/PWD)
2. MFR4200 FlexRay Microcontroller Data Sheet (MFR4200V2)
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
245
MFR4200 Protocol Implementation Document
C.2
Overall Protocol State Machine
The MFR4200 implements the overall protocol state machine according to PS V1.1/PWD, with
differences presented below.
Protocol
Operation Control
(POC)
initiate hardware
CONFIG
host: wakeup
WAKEUP
host: config complete
take over config data
CODEC on A (INIT),
CODEC on B (INIT),
FSP control on A (INIT),
FSP control on B (INIT),
MAS control on A (INIT),
MAS control on B (INIT),
CSP control (INIT)
reset status information
STARTUP
pSyncSlot ?
CODEC on A (NORMAL),
CODEC on B (NORMAL),
FSP control on A (GO),
FSP control on B (GO),
MAS control on A (ALL),
MAS control on B (ALL),
CSP control (SYNC)
=0
else
vClockCorrectionFailedCounter:=0
CODEC on A (NORMAL),
CODEC on B (NORMAL),
FSP control on A (GO),
FSP control on B (GO),
MAS control on A (ALL),
MAS control on B (ALL),
CSP control (NOSYNC)
NORMAL_ACTIVE
Figure C-1. Protocol Operation Control (POC) - 1
MFR4200 Data Sheet, Rev. 0
246
Freescale Semiconductor
Overall Protocol State Machine
not implemented
for FPGA V8.x
NORMAL_ACTIVE,
NORMAL_PASSIVE
*
low voltage
hardware reset activated
transmitter off
cycle start
(zCycleCounter)
-
*
*
(freeze)
host: config
host: freeze
internal error
transmitter off
transmitter off
CONFIG
FREEZE
red state
host: config
CONFIG
Figure C-2. Protocol Operation Control (POC) - 2
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
247
MFR4200 Protocol Implementation Document
vClockCorrectionFailed:=0
NORMAL_ACTIVE
ClockSyncState(zClockState,
zStartupPairs, zRefPair)
even
zCycleCounter ?
odd
SUCCESSFUL
zClockState ?
LIMIT_REACHED
MISSING_RATE
vClockCorrectionFailed :=
vClockCorrectionFailed + 1
vClockCorrectionFailed ?
>= gMaxWithoutClockCorrectionFatal
else
vClockCorrectionFailed ?
else
>= gMaxWithoutClockCorrectionPassive
false
NORMAL_PASSIVE
CODEC on A (NORMAL),
CODEC on B (NORMAL),
FSP control on A (GO),
FSP control on B (GO),
MAS control on A (NOCE),
MAS control on B (NOCE),
CSP control (NOSYNC)
pAllowFreezeDueToClock ?
true
CODEC on A (INIT),
CODEC on B (INIT),
FSP control on A (INIT),
FSP control on B (INIT),
MAS control on A (INIT),
MAS control on B (INIT),
CSP control (INIT)
READY
Figure C-3. POC — Normal Operation
MFR4200 Data Sheet, Rev. 0
248
Freescale Semiconductor
Coding and Decoding
NORMAL_PASSIVE
ClockSyncState(zClockState,
StartupPairs, zRefPair)
even
zCycleCounter ?
odd
MISSING_RATE
zClockState ?
SUCCESSFUL
LIMIT_REACHED
vClockCorrectionFailed ?
< gMaxWithoutClockCorrectionFatal
vClockCorrectionFailed
:= 0
else
pAllowPassiveToFreeze ?
true
vClockCorrectionFailed :=
vClockCorrectionFailed + 1;
vClockCorrectionFailed ?
false
>1
zStartupNodes?
else
=1
pStartupNode?
< gMaxWithoutClockCorrectionFatal
false
pAllowFreezeDueToClock ?
false
true
true
CODEC on A (INIT),
CODEC on B (INIT),
FSP control on A (INIT),
FSP control on B (INIT),
MAS control on A (INIT),
MAS control on B (INIT),
CSP control (INIT)
FREEZE
CODEC on A (NORMAL),
CODEC on B (NORMAL),
FSP control on A (GO),
FSP control on B (GO),
MAS control on A (ALL),
MAS control on B (ALL),
CSP control (SYNC)
pSyncSlot ?
=0
else
NORMAL_ACTIVE
CODEC on A (NORMAL),
CODEC on B (NORMAL),
FSP control on A (GO),
FSP control on B (GO),
MAS control on A (ALL),
MAS control on B (ALL),
CSP control (NOSYNC)
Figure C-4. POC — Passive Operation
C.3
Coding and Decoding
The implementation is compliant with PS V1.1, with the exception that the wakeup symbol is not detected.
C.3.1
Overview
The implementation is compliant with PS V1.1.
C.3.2
NRZ Coding
The implementation is compliant with PS V1.1.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
249
MFR4200 Protocol Implementation Document
C.3.3
NRZ Decoding
The implementation is compliant with PS V1.1.
C.3.3.1
NFZ Decoding Principles
The implementation is compliant with PS V1.1.
C.3.3.2
Frame Decoding
The implementation is compliant with PS V1.1.
C.3.3.3
Symbol Decoding
The implementation is compliant with PS V1.1.
C.3.3.3.1
Collision Resolution Symbol
The implementation is compliant with PS V1.1.
C.3.3.3.2
Wakeup Symbol
MFR4200 can generate a wakeup symbol in accordance with Section C.3.2, “NRZ Coding”. However, the
implementation does not recognize a wakeup symbol. See also Section C.7.2, “Cluster Wakeup”.
C.3.3.4
Decoding Error
The implementation is compliant with PS V1.1.
C.3.4
Signal Integrity
The implementation is compliant with PS V1.1.
C.4
Frame Format
The implementation is compliant with PS V1.1.
NOTE
The semantic of the null frame bit has been inverted compared with previous
implementations, to be compliant with PS V1.1.
C.5
Media Access Control
The implementation is compliant with PS V1.1.
NOTE
Due to the implementation, there is a lower boundary gdNIT (see
Section 3.2.3.3.18, “Network Idle Time Configuration Register (NITCR).
MFR4200 Data Sheet, Rev. 0
250
Freescale Semiconductor
Frame and Symbol Processing
C.6
Frame and Symbol Processing
The implementation is compliant with PS V1.1, with the following exceptions.
• STUP is not indicated to the host.
• Data received during startup is not provided to the host.
C.7
C.7.1
Wakeup, Startup, and Reintegration
Introduction
The implementation is compliant with PS V1.1.
C.7.2
Cluster Wakeup
The functionality of the wakeup is implemented in part only. The controller can generate wakeup symbols
on configurable channels and repeat them for a configurable number of times in accordance with
WAKEUP SEND.
WAKEUP LISTEN is not implemented. After completing WAKEUP SEND, the controller returns to the
CONFIG state.
C.7.3
Communication Startup and Reintegration
Clearing the coldstart inhibit bit after leaving 'PC_RESET' is not supported in MFR4200. This applies for
the following subsections.
C.7.3.1
Definitions and Properties
The implementation is compliant with PS V1.1.
C.7.3.2
Principle of Operation
The implementation is compliant with PS V1.1.
C.7.3.3
Coldstart Inhibit Mode
The implementation is compliant with PS V1.1.
C.7.3.4
Startup State Diagram
The implementation is compliant with PS V1.1. However, the protocol state indicated in the host interface
is incorrect for a short time, in the following case:
When the node has unsuccessfully performed a coldstart, and the number of remaining coldstart attempts
is 0, the host interface indicates that the controller has entered the coldstart listen state, and will change to
the integration listen state only after approximately one macrotick.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
251
MFR4200 Protocol Implementation Document
Moreover, in Figure 7-6 (PS V1.1), and in similar drawings for nodes B and C, the state Initialize schedule
lasts until the end of the communication cycle, rather than changing in the middle of the cycle.
C.8
C.8.1
Clock Synchronization
Introduction
The implementation is compliant with PS V1.1.
C.8.2
Time Representation
The implementation is compliant with PS V1.1.
C.8.3
Synchronization Process
Figure 8-3 (PS V1.1): In MFR4200 the measurement tables are initialized during the NIT (before cycle
start, rather than after the cycle start). The entries for the even cycle are initialized in the NIT of the odd
cycle. Likewise, the measurements of the odd cycle are initialized in the NIT of the even cycle.
C.8.4
Clock Startup
The implementation is compliant with PS V1.1.
C.8.5
Time Measurement
The implementation is compliant with PS V1.1. However, note that the clock sync measurement values
indicated in the host interface are different from the example shown in Figure 8-8 (PS V1.1).
C.8.5.1
Data Structure
The implementation is compliant with PS V1.1.
C.8.5.2
Initialization
In MFR4200, the table for the odd cycle measurements is initialized in the NIT of the even cycle, and vice
versa, rather than after the beginning of the even cycle.
C.8.6
Correction Term Calculation
Figure 8-13 (PS V1.1): MFR4200 differs slightly from this description. Startup frames are counted on a
per channel basis, with one counter for each channel, rather than one counter for both channels. For
evaluation, the maximum is taken, rather than counting a startup frame on either channel with a single
counter. Moreover, in MFR4200, the check of vOffsetCorrection is performed before the external offset
correction, rather than after external offset correction.
MFR4200 Data Sheet, Rev. 0
252
Freescale Semiconductor
Controller Host Interface
Figure 8-14 (PS V1.1): In MFR4200 the check of vRateCorrection is performed before the external offset
correction rather than after external rate correction.
C.8.7
Clock Correction
Figure 8-15 (PS V1.1): The implementation in MFR4200 is compliant with the red text in the middle of
the diagram. Moreover, when macrotick counting is reset, the host interface indication of vMacrotick is
immediately reset to 0, as soon as the macrotick counting is reset; however, internally, the macrotick
generation continues for a short time in accordance with the specification.
C.8.8
Sync Frame Configuration Rules
Table 8-3 (PS V1.1): MFR4200 supports up to 16 sync frames, rather than 15.
C.9
Controller Host Interface
The implementation of the host interface is compliant with the specification in PS V1.1. The
implementation supports the following features:
• Message filtering
— Frame ID filtering
— Cycle counter filtering
— Channel filtering
— Message ID filtering (FIFO only)
• Message FIFO (receive FIFO)
• Timer
• Error signalling
• Host interrupts
— Timer interrupt
— Error signaling interrupt
• Network management vector
C.10
Device Specific Power Modes
MFR4200 supports supervision of voltage levels, and performs a reset when the supply voltage drops
below a boundary specified in Chapter 5, “Clocks and Reset Generator.
A low power mode or sleep mode is not supported.
C.11
Bus Guardian Schedule Monitoring
The implementation is compliant with PS V1.1.
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
253
MFR4200 Protocol Implementation Document
C.12
C.12.1
System Parameters and Configuration Constraints
System Parameters
System parameters are used primarily for the protocol description and are not protocol mechanisms.
Therefore, they are almost transparent to the user in the MFR4200 implementation. The only difference
from PS V1.1 that is relevant to the user is as follows.
• cSyncNodeMax is fixed at 16.
NOTE
Parameters relating to unsupported features are not mentioned here.
C.12.2
Configuration Constraints
The implementation requires most of the constraints specified in PS V1.1 to be fulfilled. Exceptions are
bit rate configuration and bit sample clock frequency, which are configurable in a wider range than
described in PS V1.1.
NOTE
However, while fulfilling these configuration constraints is necessary, it is
not sufficient for a valid configuration.
MFR4200 Data Sheet, Rev. 0
254
Freescale Semiconductor
Appendix D
Index of Registers
A
Active FIFO Buffer Cycle Counter and Payload Length Register (AFBCCPLR) 132
Active FIFO Buffer Data n Register (AFBDATAnR) 133
Active FIFO Buffer Frame ID Register (AFBFRID) 131
Active FIFO Buffer Header CRC Register (AFBCRCR) 132
Active FIFO Buffer Message Buffer Slot Status Vector Register (AFBMBSSVR) 133
Active Receive Buffer Cycle Counter and Payload Lenth Register (ARBCCPLR) 129
Active Receive Buffer Data n Register (ARBDATAnR) 130
Active Receive Buffer Frame ID Register (ARBFRID) 129
Active Receive Buffer Header CRC Register (ARBCRCR) 130
Active Receive Buffer Message Buffer Slot Status Vector Register (ARBMBSSVR) 131
Active Transmit Buffer Cycle Counter and Payload Length Register (ATBCCPLR) 127
Active Transmit Buffer Data n Register (ATBDATAnR) 128
Active Transmit Buffer Frame ID Register (ATBFRID) 126
Active Transmit Buffer Header CRC Register (ATBCRCR) 127
Active Transmit Buffer Message Buffer Slot Status Vector Register (ATBMBSSVR) 128
B
Bit Duration Register (BDR) 71
Buffer Control, Configuration and Status n Register (BUFCSnR) 126
Bus Guardian Status Register (BGSR) 99
Bus Guardian Tick Register (BGTR) 87
C
Channel Status Error Counter n Register (CSECnR) 102
CHI Error Register (CHIER) 109
Clock Correction Failed Counter Register (CCFCR) 113
Cluster Drift Damping Register (CDDR) 73
Cold Start Maximum Register (CSMR) 84
Current Cycle Counter Value Register (CCCVR) 94
Current Macrotick Counter Value Register (CMCVR) 94
Cycle Counter Filter n Register (CCFnR) 135
Cycle Length Register (CLR) 80
D
Debug Port Control Register (DBPCR) 88
Delay Compensation Channel A Register (DCAR) 72
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
255
Index of Registers
Delay Compensation Channel B Register (DCBR) 72
Delay Counter Register (DCR) 87
E
Error Handling Level Register (EHLR) 113
Even Measurement channel A n Register (EMAnR) 122
Even Measurement channel B n Register (EMBnR) 123
Even Measurement Counter Register (EMCR) 124
Even Sync Frame ID n Register (ESFIDnR) 121
External Correction Control Register (ECCR) 82
External Offset Correction Register (EOCR) 81
External Rate Correction Register (ERCR) 82
F
FIFO Acceptance Filter Message ID Mask Register (FAFMIDMR) 136
FIFO Acceptance Filter Message ID Value Register (FAFMIDVR) 136
FIFO Acceptance/Rejection Filter Channel Register (FAFCHR) 137
FIFO Rejection Filter Frame ID Mask Register (FRFFIDMR) 138
FIFO Rejection Filter Frame ID Value Register (FRFFIDVR) 138
FIFO Size Register (FSIZR) 125
G
Global Network Management Vector n Register (GNMVnR) 96
H
Host Interface and Physical Layer Pins Drive Strength Register (HIPDSR) 67
Host Interface Pins PullUp/Down Control Register (HIPPCR) 69
Host Interface Pins PullUp/Down Enable Register (HIPPER) 68
I
Idle Detection Length Register (IDLR) 90
Interrupt Enable Register 0 (IER0) 103
Interrupt Status Register 0 (ISR0) 114
L
Latest Dynamic Transmission Start Register (LDTSR) 78
Listen timeout with Noise Length Register (LNLR) 92
MFR4200 Data Sheet, Rev. 0
256
Freescale Semiconductor
M
Magic Number Register (MNR) 63
Maximum Cycle Length Deviation Register (MCLDAR) 81
Maximum Odd Cycles Without Clock Correction Fatal Register (MOCWCFR) 101
Maximum Odd Cycles Without clock Correction Passive Register (MOCWCPR) 101
Maximum Offset Correction Register (MOCR) 83
Maximum Payload Length Dynamic Register (MPLDR) 79
Maximum Rate Correction Register (MRCR) 84
Maximum Sync Frames Register (MSFR) 73
Microticks per Cycle High Register (MPCHR) 75
Microticks per Cycle Low Register (MPCLR) 74
Minislot Action Point Offset Register (MSAPOR) 77
Minislot Length Register (MSLR) 77
Module Configuration Register 0 (MCR0) 64
Module Configuration Register 1 (MCR1) 66
Module Version Register 0 (MVR0) 62
Module Version Register 1 (MVR1) 62
N
Network Idle Time Configuration Register (NITCR) 80
Network Management Vector Length Register (NMVLR) 85
Nominal Macrotick Length Register (NMLR) 74
Number of Static Slots Register (NSSR) 76
O
Odd Measurement channel A n Register (OMAnR) 121
Odd Measurement channel B n Register (OMBnR) 122
Odd Measurement Counter Register (OMCR) 124
Odd Sync Frame ID n Register (OSFIDnR) 120
Offset Correction Value Register (OCVR) 95
P
Physical Layer Pins Drive Strength Register (PLPDSR) 68
Physical Layer Pins PullUp/Down Control Register (PLPPCR) 70
Physical Layer Pins PullUp/Down Enable Register (PLPPER) 69
Protocol State Register (PSR) 93
R
Rate Correction Value Register (RCVR) 95
Receive Buffer Interrupt Vector Register (RBIVECR) 108
MFR4200 Data Sheet, Rev. 0
Freescale Semiconductor
257
Index of Registers
S
Slot Status Counter Condition n Register (SSCCnR) 105
Slot Status Counter Incrementation Register (SSCIR) 107
Slot Status Counter Interrupt Mask Register (SSCIMR) 107
Slot Status Counter n Register (SSCnR) 104
Slot Status n Register (SSnR) 119
Slot Status Selection n Register (SSSnR) 103
Start of Offset Correction Cycle Time Register (SOCCTR) 89
Startup Interrupt Enable Register (SIER) 100
Startup Interrupt Status Register (SISR) 118
Static Payload Length Register (SPLR) 76
Static Slot Action Point Offset Register (SSAPOR) 78
Static Slot Length Register (SSLR) 75
Symbol Window Configuration Register (SWCR) 79
Symbol Window Control Register (SWCTRLR) 90
Symbol Window Status channel A Register (SWSAR) 97
Symbol Window Status channel B Register (SWSBR) 98
Sync Frame Acceptance Filter Mask Register (SYNFAFMR) 134
Sync Frame Acceptance Filter Value Register (SYNFAFVR) 134
Sync Frame Header Register (SYNCHR) 86
Sync Frame Register (SYNCFR) 86
Sync Frame Rejection Filter Register (SYNFRFR) 135
T
Timer Interrupt Configuration Register 0 Cycle Set (TICR0CS) 139
Timer Interrupt Configuration Register 0 Macrotick Offset (TICR0MO) 140
Timer Interrupt Configuration Register 1 Cycle Set (TICR1CS) 140
Timer Interrupt Configuration Register 1 Macrotick Offset (TICR1MO) 141
Transmit Buffer Interrupt Vector Register (TBIVECR) 109
Transmit Start Sequence Length Register (TSSLR) 85
V
Voltage Regulator Status Register (VREGSR) 70
W
Wakeup Mechanism Control Register (WMCTRLR) 91
Wakeup Symbol TX Idle Register (WUSTXIR) 91
Wakeup Symbol TX Low Register (WUSTXLR) 92
MFR4200 Data Sheet, Rev. 0
258
Freescale Semiconductor
How to Reach Us:
Home Page:
www.freescale.com
E-mail:
[email protected]
USA/Europe or Locations Not Listed:
Freescale Semiconductor
Technical Information Center, CH370
1300 N. Alma School Road
Chandler, Arizona 85224
+1-800-521-6274 or +1-480-768-2130
[email protected]
Europe, Middle East, and Africa:
Freescale Halbleiter Deutschland GmbH
Technical Information Center
Schatzbogen 7
81829 Muenchen, Germany
+44 1296 380 456 (English)
+46 8 52200080 (English)
+49 89 92103 559 (German)
+33 1 69 35 48 48 (French)
[email protected]
Japan:
Freescale Semiconductor Japan Ltd.
Headquarters
ARCO Tower 15F
1-8-1, Shimo-Meguro, Meguro-ku,
Tokyo 153-0064, Japan
0120 191014 or +81 3 5437 9125
[email protected]
Asia/Pacific:
Freescale Semiconductor Hong Kong Ltd.
Technical Information Center
2 Dai King Street
Tai Po Industrial Estate
Tai Po, N.T., Hong Kong
+800 2666 8080
[email protected]
For Literature Requests Only:
Freescale Semiconductor Literature Distribution Center
P.O. Box 5405
Denver, Colorado 80217
1-800-441-2447 or 303-675-2140
Fax: 303-675-2150
[email protected]
Information in this document is provided solely to enable system and
software implementers to use Freescale Semiconductor products. There are
no express or implied copyright licenses granted hereunder to design or
fabricate any integrated circuits or integrated circuits based on the
information in this document.
Freescale Semiconductor reserves the right to make changes without further
notice to any products herein. Freescale Semiconductor makes no warranty,
representation or guarantee regarding the suitability of its products for any
particular purpose, nor does Freescale Semiconductor assume any liability
arising out of the application or use of any product or circuit, and specifically
disclaims any and all liability, including without limitation consequential or
incidental damages. “Typical” parameters that may be provided in Freescale
Semiconductor data sheets and/or specifications can and do vary in different
applications and actual performance may vary over time. All operating
parameters, including “Typicals”, must be validated for each customer
application by customer’s technical experts. Freescale Semiconductor does
not convey any license under its patent rights nor the rights of others.
Freescale Semiconductor products are not designed, intended, or authorized
for use as components in systems intended for surgical implant into the body,
or other applications intended to support or sustain life, or for any other
application in which the failure of the Freescale Semiconductor product could
create a situation where personal injury or death may occur. Should Buyer
purchase or use Freescale Semiconductor products for any such unintended
or unauthorized application, Buyer shall indemnify and hold Freescale
Semiconductor and its officers, employees, subsidiaries, affiliates, and
distributors harmless against all claims, costs, damages, and expenses, and
reasonable attorney fees arising out of, directly or indirectly, any claim of
personal injury or death associated with such unintended or unauthorized
use, even if such claim alleges that Freescale Semiconductor was negligent
regarding the design or manufacture of the part.
Freescale™ and the Freescale logo are trademarks of Freescale
Semiconductor, Inc. All other product or service names are the property
of their respective owners. The ARM POWERED logo is a registered
trademark of ARM Limited. ARM7TDMI-S is a trademark of ARM Limited.
Java and all other Java-based marks are trademarks or registered
trademarks of Sun Microsystems, Inc. in the U.S. and other countries.
The Bluetooth trademarks are owned by their proprietor and used by
Freescale Semiconductor, Inc. under license.
© Freescale Semiconductor, Inc. 2004. All rights reserved.
MFR4200
Rev. 0
8/2005