D at a S hee t, DS 3, A ug . 2 00 2 FALC56 E1/T1/J1 Framer and Line Interface Component for Longand Short-Haul Applications PEB 2256 HT Version 1.2 PEB 2256 E Version 1.2 W i r ed Communications N e v e r s t o p t h i n k i n g . Data Sheet Revision History: 2002-08-27 Previous Version: DS 2 Page Subjects (major changes since last revision) 479 P-LBGA-81-1 Package Outline DS 3 For questions on technology, delivery and prices please contact the Infineon Technologies Offices in Germany or the Infineon Technologies Companies and Representatives worldwide: see our webpage at http://www.infineon.com ABM®, ABM®, ACE®, AOP®, ARCOFI®, ASM®, ASP®, DigiTape®, DuSLIC®, EPIC®, ELIC®, FALC®, GEMINAX®, IDEC®, INCA®, IOM®, IPAT®-2, ISAC®, ITAC®, IWE®, IWORX®, MUSAC®, MuSLIC®, OCTAT®, OptiPort®, POTSWIRE®, QUAT®, QuadFALC®, SCOUT®, SICOFI®, SIDEC®, SLICOFI®, SMINT®, SOCRATES®, VINETIC®, 10BaseV®, 10BaseVX® are registered trademarks of Infineon Technologies AG. 10BaseS™, EasyPort™ are trademarks of Infineon Technologies AG. Edition 2002-08-27 Published by Infineon Technologies AG, St.-Martin-Strasse 53, D-81541 München, Germany © Infineon Technologies AG 2002. All Rights Reserved. Attention please! The information herein is given to describe certain components and shall not be considered as warranted characteristics. Terms of delivery and rights to technical change reserved. We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits, descriptions and charts stated herein. Infineon Technologies is an approved CECC manufacturer. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office in Germany or our Infineon Technologies Representatives worldwide. Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. FALC56 V1.2 PEB 2256 Table of Contents Page 1 1.1 1.2 1.3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Logic Symbol ............................................ Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 19 23 24 2 2.1 2.2 2.3 Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Diagram P-MQFP-80-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Diagram P-LBGA-81-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Definitions and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 26 27 29 3 3.1 3.2 3.3 3.3.1 3.3.1.1 3.3.1.2 3.3.1.3 3.3.2 3.3.3 Functional Description E1/T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Microprocessor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mixed Byte/Word Access to the FIFOs . . . . . . . . . . . . . . . . . . . . . . . FIFO Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Boundary Scan Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Master Clocking Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 50 51 52 52 52 53 55 57 59 4 Functional Description E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Receive Path in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.1 Receive Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.2 Receive Short and Long-Haul Interface . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.3 Receive Equalization Network (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.4 Receive Line Attenuation Indication (E1) . . . . . . . . . . . . . . . . . . . . . . . . 4.1.5 Receive Clock and Data Recovery (E1) . . . . . . . . . . . . . . . . . . . . . . . . 4.1.6 Receive Line Coding (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.7 Receive Line Monitoring Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.8 Loss-of-Signal Detection (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.9 Receive Jitter Attenuator (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.10 Jitter Tolerance (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.11 Output Jitter (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.12 Framer/Synchronizer (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.13 Receive Elastic Buffer (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.14 Receive Signaling Controller (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.14.1 HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.14.2 Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.14.3 Sa-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.14.4 Channel Associated Signaling CAS (E1, serial mode) . . . . . . . . . . . 4.1.14.5 Channel Associated Signaling CAS (E1, µP access mode) . . . . . . . 4.2 Framer Operating Modes (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 60 60 60 61 61 61 62 63 65 66 69 69 70 70 73 73 74 76 76 77 79 79 Data Sheet 3 2002-08-27 FALC56 V1.2 PEB 2256 Table of Contents 4.2.2 4.2.2.1 4.2.2.2 4.2.2.3 4.2.2.4 4.2.3 4.2.3.1 4.2.3.2 4.2.3.3 4.2.3.4 4.2.3.5 4.2.3.6 4.2.3.7 4.2.3.8 4.3 4.3.1 4.3.2 4.3.3 4.3.4 4.3.5 4.3.6 4.3.7 4.4 4.4.1 4.4.2 4.4.3 4.4.4 4.4.5 4.4.6 4.4.7 4.4.7.1 4.4.7.2 4.4.7.3 4.4.7.4 4.4.7.5 4.5 4.5.1 4.5.1.1 4.5.2 4.5.2.1 4.5.3 4.6 Page Doubleframe Format (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Transmit Transparent Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 A-Bit Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Sa-Bit Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 CRC-Multiframe (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Automatic Force Resynchronization (E1) . . . . . . . . . . . . . . . . . . . . . 85 Floating Multiframe Alignment Window (E1) . . . . . . . . . . . . . . . . . . . 85 CRC4 Performance Monitoring (E1) . . . . . . . . . . . . . . . . . . . . . . . . . 85 Modified CRC4 Multiframe Alignment Algorithm (E1) . . . . . . . . . . . . 85 A-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Sa-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 E-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Additional Receive Framer Functions (E1) . . . . . . . . . . . . . . . . . . . . . . . . 90 Error Performance Monitoring and Alarm Handling . . . . . . . . . . . . . . . . 90 Auto Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Errored Second . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 One-Second Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 In-Band Loop Generation and Detection . . . . . . . . . . . . . . . . . . . . . . . . 92 Time Slot 0 Transparent Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Transmit Path in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Transmitter (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Transmit Line Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Transmit Jitter Attenuator (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Transmit Elastic Buffer (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Programmable Pulse Shaper (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Transmit Line Monitor (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Transmit Signaling Controller (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Sa-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Channel Associated Signaling CAS (E1, serial mode) . . . . . . . . . . 101 Channel Associated Signaling CAS (E1, µP access mode) . . . . . . 101 System Interface in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Receive System Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Receive Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Transmit System Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Transmit Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Time Slot Assigner (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Test Functions (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Data Sheet 4 2002-08-27 FALC56 V1.2 PEB 2256 Table of Contents 4.6.1 4.6.2 4.6.3 4.6.4 4.6.5 4.6.6 4.6.7 Page Pseudo-Random Binary Sequence Generation and Monitor . . . . . . . . Remote Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Payload Loop-Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Channel Loop-Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm Simulation (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Bit Defect Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 114 115 116 117 118 118 5 Functional Description T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Receive Path in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.1 Receive Line Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2 Receive Short and Long-Haul Interface (T1/J1) . . . . . . . . . . . . . . . . . 5.1.3 Receive Equalization Network (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.4 Receive Line Attenuation Indication (T1/J1) . . . . . . . . . . . . . . . . . . . . 5.1.5 Receive Clock and Data Recovery (T1/J1) . . . . . . . . . . . . . . . . . . . . . 5.1.6 Receive Line Coding (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.7 Receive Line Monitoring Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.8 Loss-of-Signal Detection (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.9 Receive Jitter Attenuator (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.10 Jitter Tolerance (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.11 Output Jitter (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.12 Framer/Synchronizer (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.13 Receive Elastic Buffer (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.14 Receive Signaling Controller (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.14.1 HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.14.2 Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.14.3 CAS Bit-Robbing (T1/J1, serial mode) . . . . . . . . . . . . . . . . . . . . . . . 5.1.14.4 CAS Bit-Robbing (T1/J1, µP access mode) . . . . . . . . . . . . . . . . . . . 5.1.14.5 Bit Oriented Messages in ESF-DL Channel (T1/J1) . . . . . . . . . . . . 5.1.14.6 4 kbit/s Data Link Access in F72 Format (T1/J1) . . . . . . . . . . . . . . . 5.2 Framer Operating Modes (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.2 General Aspects of Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.3 Addition for F12 and F72 Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.4 4-Frame Multiframe (F4 Format, T1/J1) . . . . . . . . . . . . . . . . . . . . . . . 5.2.4.1 Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.5 12-Frame Multiframe (D4 or SF Format, T1/J1) . . . . . . . . . . . . . . . . . 5.2.5.1 Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.6 Extended Superframe (F24 or ESF Format, T1/J1) . . . . . . . . . . . . . . . 5.2.6.1 Synchronization Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.6.2 Remote Alarm (yellow alarm) Generation/Detection . . . . . . . . . . . . 5.2.6.3 CRC6 Generation and Checking (T1/J1) . . . . . . . . . . . . . . . . . . . . . 5.2.7 72-Frame Multiframe (SLC96 Format, T1/J1) . . . . . . . . . . . . . . . . . . . 119 119 119 119 120 120 120 121 123 124 125 128 129 129 129 134 134 135 137 137 137 138 139 139 139 140 142 142 143 143 144 145 146 146 146 Data Sheet 5 2002-08-27 FALC56 V1.2 PEB 2256 Table of Contents Page 5.2.7.1 5.2.8 5.3 5.3.1 5.3.2 5.3.3 5.3.4 5.3.5 5.3.6 5.3.7 5.3.8 5.3.9 5.4 5.4.1 5.4.2 5.4.3 5.4.4 5.4.5 5.4.6 5.4.7 5.4.7.1 5.4.7.2 5.4.7.3 5.4.7.4 5.4.7.5 5.4.7.6 5.5 5.5.1 5.5.1.1 5.5.2 5.5.2.1 5.5.3 5.6 5.6.1 5.6.2 5.6.3 5.6.4 5.6.5 5.6.6 5.6.7 5.7 Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary of Frame Conditions (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . Additional Receive Framer Functions (T1/J1) . . . . . . . . . . . . . . . . . . . . . Error Performance Monitoring and Alarm Handling . . . . . . . . . . . . . . . Auto Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Errored Second . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . One-Second Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clear Channel Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . In-Band Loop Generation and Detection . . . . . . . . . . . . . . . . . . . . . . . Transparent Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pulse-Density Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Path in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitter (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Line Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Jitter Attenuator (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Elastic Buffer (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programmable Pulse Shaper and Line Build-Out (T1/J1) . . . . . . . . . . Transmit Line Monitor (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Signaling Controller (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . . CAS Bit-Robbing (T1/J1, serial mode) . . . . . . . . . . . . . . . . . . . . . . . CAS Bit-Robbing (T1/J1, µP access mode) . . . . . . . . . . . . . . . . . . . Data Link Access in ESF/F24 and F72 Format (T1/J1) . . . . . . . . . . Periodical Performance Report in ESF Format (T1/J1) . . . . . . . . . . System Interface in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive System Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit System Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time Slot Assigner (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test Functions (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pseudo-Random Binary Sequence Generation and Monitor . . . . . . . . Remote Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Payload Loop-Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Channel Loop-Back (loop-back of time slots) . . . . . . . . . . . . . . Alarm Simulation (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Bit Defect Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J1-Feature Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operational Description E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Data Sheet 6 147 149 150 150 151 152 152 152 153 153 153 153 154 154 154 155 157 159 160 160 160 161 161 162 162 162 165 167 168 172 178 180 182 182 182 183 184 185 186 186 187 2002-08-27 FALC56 V1.2 PEB 2256 Table of Contents Page 6.1 6.2 6.3 Operational Overview E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Device Reset E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Device Initialization in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 7 7.1 7.2 7.3 Operational Description T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operational Overview T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Reset T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Initialization in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 194 194 194 8 8.1 8.1.1 8.1.2 8.1.3 8.1.4 8.1.5 8.1.6 8.2 8.3 8.3.1 8.3.2 8.3.3 8.3.4 8.3.5 8.3.6 8.3.7 8.3.8 Signaling Controller Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . HDLC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-Auto Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transparent Mode 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transparent Mode 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SS7 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Extended Transparent Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signaling Controller Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transparent Transmission and Reception . . . . . . . . . . . . . . . . . . . . . . CRC on/off Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive Address Pushed to RFIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLC Data Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLC Data Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sa-bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bit Oriented Message Mode (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . Data Link Access in ESF/F72 Format (T1/J1) . . . . . . . . . . . . . . . . . . . 201 201 201 202 202 202 202 204 204 205 205 205 206 206 208 208 209 211 9 9.1 9.2 9.3 9.4 E1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E1 Control Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Detailed Description of E1 Control Registers . . . . . . . . . . . . . . . . . . . . . E1 Status Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Detailed Description of E1 Status Registers . . . . . . . . . . . . . . . . . . . . . . 213 213 217 286 289 10 10.1 10.2 10.3 10.4 T1/J1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T1/J1 Control Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Detailed Description of T1/J1 Control Registers . . . . . . . . . . . . . . . . . . . T1/J1 Status Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Detailed Description of T1/J1 Status Registers . . . . . . . . . . . . . . . . . . . . 330 330 334 407 409 11 11.1 11.2 11.3 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 446 446 447 Data Sheet 7 2002-08-27 FALC56 V1.2 PEB 2256 Table of Contents Page 11.4 11.4.1 11.4.2 11.4.3 11.4.4 11.4.4.1 11.4.4.2 11.4.5 11.4.6 11.4.7 11.4.7.1 11.4.7.2 11.5 11.6 11.7 11.7.1 11.7.2 AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Master Clock Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JTAG Boundary Scan Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Microprocessor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intel Bus Interface Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motorola Bus Interface Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pulse Templates - Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pulse Template E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pulse Template T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Capacitances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Package Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Package Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478 13 13.1 13.2 13.3 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484 Data Sheet 8 450 450 451 452 453 453 456 458 460 472 472 473 474 474 475 475 476 480 480 481 481 2002-08-27 FALC56 V1.2 PEB 2256 List of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 Data Sheet Page Logic Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Multiple E1/T1/J1 Link over Frame Relay . . . . . . . . . . . . . . . . . . . . . . 24 8-Channel E1/T1/J1-Interface to the ATM Layer . . . . . . . . . . . . . . . . . 25 Pin Configuration P-MQFP-80-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Pin Configuration P-LBGA-81-1 (bottom view) . . . . . . . . . . . . . . . . . . 27 Pin Configuration P-LBGA-81-1 (top view) . . . . . . . . . . . . . . . . . . . . . 28 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 FIFO Word Access (Intel Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 FIFO Word Access (Motorola Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Interrupt Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Block Diagram of Test Access Port and Boundary Scan . . . . . . . . . . . 57 Flexible Master Clock Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Receive Clock System (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Receiver Configuration (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Receive Line Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Protection Switching Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Jitter Attenuation Performance (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Jitter Tolerance (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 The Receive Elastic Buffer as Circularly Organized Memory . . . . . . . 72 Automatic Handling of Errored Signaling Units . . . . . . . . . . . . . . . . . . 75 2.048 MHz Receive Signaling Highway (E1) . . . . . . . . . . . . . . . . . . . . 77 CRC4 Multiframe Alignment Recovery Algorithms (E1). . . . . . . . . . . . 89 Transmitter Configuration (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Transmit Clock System (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Transmit Line Monitor Configuration (E1) . . . . . . . . . . . . . . . . . . . . . . 99 2.048 MHz Transmit Signaling Highway (E1) . . . . . . . . . . . . . . . . . . 101 System Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Receive System Interface Clocking (E1) . . . . . . . . . . . . . . . . . . . . . . 105 SYPR Offset Programming (2.048 Mbit/s, 2.048 MHz) . . . . . . . . . . . 107 SYPR Offset Programming (8.192 Mbit/s, 8.192 MHz) . . . . . . . . . . . 107 RFM Offset Programming (2.048 Mbit/s, 2.048 MHz) . . . . . . . . . . . . 108 RFM Offset Programming (8.192 Mbit/s, 8.192 MHz) . . . . . . . . . . . . 108 Transmit System Interface Clocking: 2.048 MHz (E1) . . . . . . . . . . . . 109 Transmit System Interface Clocking: 8.192 MHz/4.096 Mbit/s (E1). . 110 SYPX Offset Programming (2.048 Mbit/s, 2.048 MHz) . . . . . . . . . . . 112 SYPX Offset Programming (8.192 Mbit/s, 8.192 MHz) . . . . . . . . . . . 112 Remote Loop (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Payload Loop (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Local Loop (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Single Channel Loop-Back (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Receive Clock System (T1/J1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Receiver Configuration (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 9 2002-08-27 FALC56 V1.2 PEB 2256 List of Figures Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 Figure 63 Figure 64 Figure 65 Figure 66 Figure 67 Figure 68 Figure 69 Figure 70 Figure 71 Figure 72 Figure 73 Figure 74 Figure 75 Figure 76 Figure 77 Figure 78 Figure 79 Figure 80 Figure 81 Figure 82 Figure 83 Figure 84 Data Sheet Page Receive Line Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protection Switching Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . Jitter Attenuation Performance (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . Jitter Tolerance (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Receive Elastic Buffer as Circularly Organized Memory . . . . . . Automatic Handling of Errored Signaling Units . . . . . . . . . . . . . . . . . Influences on Synchronization Status (T1/J1) . . . . . . . . . . . . . . . . . . Transmitter Configuration (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . Clocking in Remote Loop Configuration (T1/J1) . . . . . . . . . . . . . . . . Transmit Clock System (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Line Monitor Configuration (T1/J1) . . . . . . . . . . . . . . . . . . . System Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive System Interface Clocking (T1/J1) . . . . . . . . . . . . . . . . . . . . SYPR Offset Programming (1.544 Mbit/s, 1.544 MHz) . . . . . . . . . . . SYPR Offset Programming (6.176 Mbit/s, 6.176 MHz) . . . . . . . . . . . RFM Offset Programming (1.544 Mbit/s, 1.544 MHz) . . . . . . . . . . . . RFM Offset Programming (6.176 Mbit/s, 6.176 MHz) . . . . . . . . . . . . 2.048 MHz Receive Signaling Highway (T1/J1). . . . . . . . . . . . . . . . . Receive FS/DL-Bits in Time Slot 0 on RDO (T1/J1) . . . . . . . . . . . . . 1.544 MHz Receive Signaling Highway (T1/J1). . . . . . . . . . . . . . . . . Transmit System Clocking: 1.544 MHz (T1/J1) . . . . . . . . . . . . . . . . . Transmit System Clocking: 8.192 MHz/4.096 Mbit/s (T1/J1) . . . . . . . 2.048 MHz Transmit Signaling Clocking (T1/J1) . . . . . . . . . . . . . . . . 1.544 MHz Transmit Signaling Highway (T1/J1) . . . . . . . . . . . . . . . . Signaling Marker for CAS/CAS-CC Applications (T1/J1) . . . . . . . . . . Signaling Marker for CAS-BR Applications (T1/J1) . . . . . . . . . . . . . . Transmit FS/DL Bits on XDI (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . SYPX Offset Programming (1.544 Mbit/s, 1.544 MHz) . . . . . . . . . . . SYPX Offset Programming (6.176 Mbit/s, 6.176 MHz) . . . . . . . . . . . Remote Loop (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Payload Loop (T1/J1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Loop (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Channel Loop-Back (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLC Receive Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLC Transmit Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Driven Data Transmission (flow diagram) . . . . . . . . . . . . . . Interrupt Driven Transmission Example . . . . . . . . . . . . . . . . . . . . . . . Interrupt Driven Reception Sequence Example . . . . . . . . . . . . . . . . . MCLK Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JTAG Boundary Scan Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intel Non-Multiplexed Address Timing . . . . . . . . . . . . . . . . . . . . . . . . 10 123 124 127 128 133 136 141 155 156 157 160 166 167 169 169 170 170 171 171 172 173 174 175 175 176 177 178 179 179 182 183 184 185 203 204 207 207 208 450 451 452 453 2002-08-27 FALC56 V1.2 PEB 2256 List of Figures Figure 85 Figure 86 Figure 87 Figure 88 Figure 89 Figure 90 Figure 91 Figure 92 Figure 93 Figure 94 Figure 95 Figure 96 Figure 97 Figure 98 Figure 99 Figure 100 Figure 101 Figure 102 Figure 103 Figure 104 Figure 105 Figure 106 Figure 107 Figure 108 Figure 109 Figure 110 Data Sheet Page Intel Multiplexed Address Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intel Read Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intel Write Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motorola Read Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motorola Write Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Line Interface Receive Timing . . . . . . . . . . . . . . . . . . . . . . . . Digital Line Interface Transmit Timing . . . . . . . . . . . . . . . . . . . . . . . . RCLK, RFSP Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCLKR/SCLKX Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Interface Marker Timing (Receive) . . . . . . . . . . . . . . . . . . . . SYPR, SYPX Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Interface Marker Timing (Transmit). . . . . . . . . . . . . . . . . . . . XDI, XSIG Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TCLK Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XCLK Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEC Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FSC Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SYNC Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E1 Pulse Shape at Transmitter Output . . . . . . . . . . . . . . . . . . . . . . . T1 Pulse Shape at the Cross Connect Point . . . . . . . . . . . . . . . . . . . Thermal Behavior of Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input/Output Waveforms for AC Testing . . . . . . . . . . . . . . . . . . . . . . Device Configuration for Power Supply Testing . . . . . . . . . . . . . . . . Protection Circuitry Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Master Clock Frequency Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . External Line Frontend Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 453 454 454 456 456 458 458 460 461 462 463 465 466 467 468 469 470 471 472 473 474 475 476 480 482 483 2002-08-27 FALC56 V1.2 PEB 2256 List of Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Table 26 Table 27 Table 28 Table 29 Table 30 Table 31 Table 32 Table 33 Table 34 Table 35 Table 36 Table 37 Table 38 Table 39 Table 40 Table 41 Table 42 Data Sheet Page Pin Definitions - Microprocessor Interface . . . . . . . . . . . . . . . . . . . . . . 29 Pin Definitions - Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Pin Definitions - Clock Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Pin Definitions - System Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Pin Definitions - Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Data Bus Access (16-Bit Intel Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Data Bus Access (16-Bit Motorola Mode) . . . . . . . . . . . . . . . . . . . . . . 52 Selectable Bus and Microprocessor Interface Configuration . . . . . . . . 53 TAP Controller Instruction Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 RCLK Output Selection (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Recommended Receiver Configuration Values (E1) . . . . . . . . . . . . . 63 External Component Recommendations (Monitoring) . . . . . . . . . . . . . 64 System Clocking (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Output Jitter (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Receive Buffer Operating Modes (E1) . . . . . . . . . . . . . . . . . . . . . . . . . 71 Allocation of Bits 1 to 8 of Time Slot 0 (E1) . . . . . . . . . . . . . . . . . . . . . 80 Transmit Transparent Mode (Doubleframe E1) . . . . . . . . . . . . . . . . . . 81 CRC-Multiframe Structure (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Transmit Transparent Mode (CRC Multiframe E1) . . . . . . . . . . . . . . . 84 Summary of Alarm Detection and Release (E1) . . . . . . . . . . . . . . . . . 90 Recommended Transmitter Configuration Values (E1) . . . . . . . . . . . . 95 Transmit Buffer Operating Modes (E1) . . . . . . . . . . . . . . . . . . . . . . . . 98 System Clocking and Data Rates (E1) . . . . . . . . . . . . . . . . . . . . . . . 102 Time Slot Assigner HDLC Channel 1 (E1) . . . . . . . . . . . . . . . . . . . . . 113 RCLK Output Selection (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Recommended Receiver Configuration Values (T1/J1). . . . . . . . . . . 122 External Component Recommendations (Monitoring) . . . . . . . . . . . . 123 System Clocking (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Output Jitter (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Channel Translation Modes (DS1/J1) . . . . . . . . . . . . . . . . . . . . . . . . 131 Receive Buffer Operation Modes (T1/J1) . . . . . . . . . . . . . . . . . . . . . 132 Resynchronization Timing (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 4-Frame Multiframe Structure (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . 142 12-Frame Multiframe Structure (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . 143 Extended Superframe Structure (F24, ESF; T1/J1) . . . . . . . . . . . . . . 144 72-Frame Multiframe Structure (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . 148 Summary Frame Recover/Out of Frame Conditions (T1/J1) . . . . . . . 149 Summary of Alarm Detection and Release (T1/J1) . . . . . . . . . . . . . . 150 Recommended Transmitter Configuration Values (T1/J1). . . . . . . . . 155 Transmit Buffer Operating Modes (T1/J1) . . . . . . . . . . . . . . . . . . . . . 159 Pulse Shaper Programming (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . 159 Structure of Periodical Performance Report (T1/J1) . . . . . . . . . . . . . 163 12 2002-08-27 FALC56 V1.2 PEB 2256 List of Tables Table 43 Table 44 Table 45 Table 46 Table 47 Table 48 Table 49 Table 50 Table 51 Table 52 Table 53 Table 54 Table 55 Table 56 Table 57 Table 58 Table 59 Table 60 Table 61 Table 62 Table 63 Table 64 Table 65 Table 66 Table 67 Table 68 Table 69 Table 70 Table 71 Table 72 Table 73 Table 74 Table 75 Table 76 Table 77 Table 78 Table 79 Table 80 Table 81 Table 82 Table 83 Table 84 Data Sheet Page Bit Functions in Periodical Performance Report . . . . . . . . . . . . . . . . System Clocking and Data Rates (T1/J1) . . . . . . . . . . . . . . . . . . . . . Time Slot Assigner HDLC Channel 1 (T1/J1) . . . . . . . . . . . . . . . . . . Initial Values after Reset (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initialization Parameters (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Line Interface Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Framer Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLC Controller Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . CAS-CC Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initial Values after reset and FMR1.PMOD = 1 (T1/J1) . . . . . . . . . . . Initialization Parameters (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Line Interface Initialization (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . Framer Initialization (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLC Controller Initialization (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . Initialization of the CAS-BR Controller (T1/J1). . . . . . . . . . . . . . . . . . E1 Control Register Address Arrangement . . . . . . . . . . . . . . . . . . . . Transmit CAS Registers (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock Mode Register Settings for E1 or T1/J1 . . . . . . . . . . . . . . . . . . E1 Status Register Address Arrangement . . . . . . . . . . . . . . . . . . . . . Receive CAS Registers (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T1/J1 Control Register Address Arrangement . . . . . . . . . . . . . . . . . . Pulse Shaper Programming (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . Transmit Signaling Registers (T1/J1). . . . . . . . . . . . . . . . . . . . . . . . . Clock Mode Register Settings for E1 or T1/J1 . . . . . . . . . . . . . . . . . . T1/J1 Status Register Address Arrangement . . . . . . . . . . . . . . . . . . Alarm Simulation States. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive Signaling Registers (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . MCLK Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JTAG Boundary Scan Timing Parameter Values. . . . . . . . . . . . . . . . Reset Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intel Bus Interface Timing Parameter Values . . . . . . . . . . . . . . . . . . Motorola Bus Interface Timing Parameter Values . . . . . . . . . . . . . . . Digital Line Interface Parameter Values . . . . . . . . . . . . . . . . . . . . . . RCLK, RFSP Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . SCLKR/SCLKX Timing Parameter Values. . . . . . . . . . . . . . . . . . . . . System Interface Marker Timing Parameter Values . . . . . . . . . . . . . SYPR/SYPX Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . System Interface Marker Timing Parameter Values . . . . . . . . . . . . . XDI, XSIG Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . TCLK Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . XCLK Timing Parameter values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEC Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 164 165 180 188 190 191 192 192 193 194 197 198 199 200 200 213 263 280 286 322 330 361 383 401 407 415 438 450 451 452 455 457 459 460 461 462 463 465 466 467 468 469 2002-08-27 FALC56 V1.2 PEB 2256 List of Tables Table 85 Table 86 Table 87 Table 88 Table 89 Table 90 Table 91 Data Sheet Page FSC Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SYNC Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . T1 Pulse Template at Cross Connect Point (T1.102) . . . . . . . . . . . . Package Characteristic Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Test Conditions E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Test Conditions T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . 14 470 471 473 474 475 476 477 2002-08-27 FALC56 V1.2 PEB 2256 Preface The FALC56 framer and line interface component is designed to fulfill all required interfacing between an analog E1/T1/J1 line and the digital PCM system highway/H.100 bus. The digital functions as well as the analog characteristics are configured via a flexible microprocessor interface. Data Sheet 15 2002-08-27 FALC56 V1.2 PEB 2256 Organization of this Document This Data Sheet is organized as follows: • Chapter 1, Introduction Gives a general description of the product and its family, lists the key features, and presents some typical applications. • Chapter 2, Pin Descriptions Lists pin locations with associated signals, categorizes signals according to function, and describes signals. • Chapter 3 to Chapter 5, Functional Description E1/T1/J1 These chapters describe the functional blocks and principle operation modes, organized into separate sections for E1 and T1/J1 operation • Chapter 6 and Chapter 7, Operational Description E1/T1/J1 Shows the operation modes and how they are to be initialized (separately for E1 and T1/J1). • Chapter 8, Signaling Controller Operating Modes Describes signaling controller functions for both E1 and T1/J1 operation. • Chapter 9 and Chapter 10, E1 Registers and T1/J1 Registers Gives a detailed description of all implemented registers and how to use them in different applications/configurations. • Chapter 11, Electrical Characteristics Specifies maximum ratings, DC and AC characteristics. • Chapter 12, Package Outlines Shows the mechanical values of the device packages. • Chapter 13, Appendix Gives an example for overvoltage protection and information about application notes and other support. • Chapter 14, Glossary • Index Data Sheet 16 2002-08-27 FALC56 V1.2 PEB 2256 Related Documentation A detailed description of changes from version 1.1 to 1.2 is given in the "PEB 2256 Version 1.2 Delta Sheet". This document refers to the following international standards (in alphabetical/numerical order): ANSI/EIA-656 ANSI T1.102 ANSI T1.403 AT&T PUB 43802 AT&T PUB 54016 AT&T PUB 62411 ESD Ass. Standard EOS/ESD-5.1-1993 ETSI ETS 300 011 ETIS ETS 300 166 ETSI ETS 300 233 ETSI ETS 300 324 ETSI ETS 300 347 ETSI TBR12 ETSI TBR13 FCC Part68 GR-253-CORE GR-499-CORE GR-1089-CORE H.100 H-MVIP IEEE 1149.1 ITU-T G.703 ITU-T G.704 ITU-T G.705 ITU-T G.706 ITU-T G.732 ITU-T G.735 ITU-T G.736 ITU-T G.737 ITU-T G.738 ITU-T G.739 ITU-T G.823 ITU-T G.824 ITU-T G.962 ITU-T G.963 ITU-T G.964 ITU-T I.431 ITU-Q.703 JT-G703 JT-G704 JT-G706 JT-I431 MIL-Std. 883D TR-TSY-000009 UL 1459 Your Comments We welcome your comments on this document. We are continuously trying improving our documentation. Please send your remarks and suggestions by e-mail to [email protected] Please provide in the subject of your e-mail: device name (FALC56), device number (PEB 2256 HT), device version (Version 1.2), and in the body of your e-mail: document type (Data Sheet), issue date (2002-08-27) and document revision number (DS 3). Data Sheet 17 2002-08-27 FALC56 V1.2 PEB 2256 Introduction 1 Introduction The FALC56 framer and line interface component is designed to fulfill all required interfacing between analog E1/T1/J1 lines and the digital PCM system highway, H.100/H.110 or H-MVIP bus for world market telecommunication systems. Due to its multitude of implemented functions, it fits to a wide range of networking applications and fulfills the according international standards. An integrated signaling controller including Signaling System #7 (SS7) support reduces software overhead. Crystal-less jitter attenuation with only one master clock source reduces the amount of required external components. Equipped with a flexible microprocessor interface, it connects to any control processor environment. A standard boundary scan interface is provided to support board level testing. Flat pack or BGA device packaging, minimum number of external components and low power consumption lead to reduced overall system costs. Other members of the FALC® family are the FALC®54 for short-haul applications, the FALC®-LH for long-haul and short-haul applications as well as the QuadFALC supporting four channels on a single chip. Data Sheet 18 2002-08-27 E1/T1/J1 Framer and Line Interface Component for Long- and Short-Haul Applications FALC56 PEB 2256 HT Version 1.2 1.1 Features Line Interface • High-density, generic interface for all E1/T1/J1 applications • Analog receive and transmit circuits for long-haul and short-haul applications P-MQFP-80-1 • E1 or T1/J1 mode selectable • Data and clock recovery using an integrated digital phase-locked loop • Maximum line attenuation up to -43 dB at 1024 kHz (E1) and up to -36 dB at 772 kHz (T1/J1) • Programmable transmit pulse shapes for E1 and T1/J1 pulse masks • Programmable line build-out for CSU signals according to ANSI T1. 403 and FCC68: 0dB, -7.5dB, P-LBGA-81-1 -15dB, -22.5 dB (T1/J1) • Low transmitter output impedances for high transmit return loss • Tristate function of the analog transmit line outputs • Transmit line monitor protecting the device from damage • Receive line monitor mode • Jitter specifications of ITU-T I.431, G.703, G.736 (E1), G.823 (E1) and AT&T TR62411 (T1/J1) are met • Crystal-less wander and jitter attenuation/compensation • Common master clock reference for E1 and T1/J1 (any frequency within 1.02 and 20 MHz) • Power-down function Type Package PEB 2256 HT P-MQFP-80-1 PEB 2256 E P-LBGA-81-1 Data Sheet 19 2002-08-27 FALC56 V1.2 PEB 2256 Introduction • • • • • • • • • • Support of automatic protection switching Dual-rail or single-rail digital inputs and outputs Unipolar NRZ or CMI for interfacing fiber-optical transmission routes Selectable line codes (E1: HDB3, AMI/T1: B8ZS, AMI with ZCS) Loss-of-signal indication with programmable thresholds according to ITU-T G.775, ETS300233 (E1) and ANSI T1.403 (T1/J1) Optional data stream muting upon LOS detection Programmable receive slicer threshold Clock generator for jitter-free system/transmit clocks per channel Local loop and remote loop for diagnostic purposes Low power device, single power supply: 3.3 V with 5 V tolerant digital inputs Frame Aligner • Frame alignment/synthesis for 2048 kbit/s according to ITU-T G.704 (E1) and for 1544 kbit/s according to ITU-T G.704 and JT G.704 (T1/J1) • Programmable frame formats: E1: Doubleframe, CRC multiframe (E1) T1: 4-frame multiframe (F4,FT), 12-frame multiframe (F12, D3/4), extended superframe (F24, ESF), remote switch mode (F72, SLC96) • Selectable conditions for recover/loss of frame alignment • CRC4 to non-CRC4 interworking according to ITU-T G. 706 Annex B (E1) • Error checking via CRC4 procedures according to ITU-T G. 706 (E1) • Error checking via CRC6 procedures according to ITU-T G. 706 and JT G.706 (T1/J1) • Performs synchronization in ESF format according to NTT requirements (J1) • Alarm and performance monitoring per second 16 bit counter for CRC-errors, framing errors, code violations, error monitoring via E-bit and SA6-bit (E1), errored blocks, PRBS bit errors • Insertion and extraction of alarm indication signals (AIS, remote/yellow alarm,…) • Remote alarm generation/checking according to ITU JT-G.704 in ESF-format (J1) • IDLE code insertion for selectable channels • Single-bit defect insertion • Flexible system clock frequency for receiver and transmitter • Supports programmable system data rates with independent receive/transmit shifts: E1: 2.048, 4.096, 8.192 and 16.384 Mbit/s (according to H.100/H.110 bus) T1/J1: 2.048, 4.096, 8.192, 16.384 Mbit/s and 1.544, 3.088, 6.176, 12.352 Mbit/s • Elastic store for receive and transmit route clock wander and jitter compensation; controlled slip capability and slip indication • Programmable elastic buffer size: 2 frames/1 frame/short buffer/bypass • Provides different time slot mapping modes • Supports fractional E1 or T1/J1 access • Flexible transparent modes • Programmable in-band loop code detection and generation (TR62411) Data Sheet 20 2002-08-27 FALC56 V1.2 PEB 2256 Introduction • Channel loop back, line loop back or payload loop back capabilities (TR54016) • Pseudo-random binary sequence generator and monitor (framed or unframed) • Clear channel capabilities (T1/J1) • Loop-timed mode Signaling Controller • Three HDLC controllers Bit stuffing, CRC check and generation, flag generation, flag and address recognition, handling of bit oriented functions • Supports signaling system #7 delimitation, alignment and error detection according to ITU-Q.703 processing of fill in signaling units, processing of errored signaling units • CAS/CAS-BR controller with last look capability, enhanced CAS-register access and freeze signaling indication • DL-channel protocol for ESF format according to ANSI T1.403 specification or according to AT&T TR54016 (T1/J1) • DL-bit access for F72 (SLC96) format (T1/J1) • Generates periodical performance report according to ANSI T1. 403 • Provides access to serial signaling data streams • Multiframe synchronization and synthesis according to ITU-T G.732 • Alarm insertion and detection (AIS and LOS in time slot 16) • Transparent mode • FIFO buffers (64 bytes deep) for efficient transfer of data packets • Time slot assignment Any combination of time slots selectable for data transfer independent of signaling mode (useful for fractional T1/J1 applications) • Time-slot 0 Sa8...4-bit handling via FIFOs (E1) • HDLC access to any Sa-bit combination (E1) Microprocessor Interface • • • • • • 8/16-bit microprocessor bus interface (Intel or Motorola type) All registers directly accessible (byte or word access) Multiplexed and non-multiplexed address bus operations Hard/software reset options Extended interrupt capabilities One-second timer (internal or external timing reference) Data Sheet 21 2002-08-27 FALC56 V1.2 PEB 2256 Introduction General • • • • • • Boundary scan standard IEEE 1149.1 P-LBGA-81-1 package; body size 10 mm × 10 mm; ball pitch 1.0 mm or P-MQFP-80-1 package; body size 14 mm × 14 mm; lead pitch 0.5 mm Temperature range from -40 to +85 °C 3.3 V power supply, digital inputs 5V tolerant Typical power consumption 250 mW Applications • • • • • • • • Wireless basestations E1/T1/J1 ATM gateways, multiplexer E1/T1/J1 Channel & Data Service Units (CSU, DSU) E1/T1/J1 Internet access equipment LAN/WAN router ISDN PRI, PABX Digital Access Crossconnect Systems (DACS) SONET/SDH add/drop multiplexer Data Sheet 22 2002-08-27 FALC56 V1.2 PEB 2256 Introduction 1.2 Logic Symbol Receive Line Interface SEC/FSC CLK2 CLK1 SYNC MCLK RCLK VDDR VSSR System Clocks RL1/RDIP/ROID SCLKR RDO RL2/RDIN/RCLKI RPA RPB TRS RPC TDI Boundary Scan Receive System Interface RPD TMS FALC 56 PEB 2256 R TCK TDO SCLKX XDI Figure 1 Data Sheet Transmit System Interface INT RES IM DBW XPD ALE VSSX BHE/BLE XPC RD/DS VDDX WR/RW XPB CS XL2/XDON A0...A7 XPA D0...D15 XL1/XDOP/XOID VSS VDD Transmit Line Interface Microprocessor Interface ITL10712 23 2002-08-27 Logic Symbol FALC56 V1.2 PEB 2256 Introduction 1.3 Typical Applications The figures show a multiple link application for Frame Relay applications using the FALC®56 together with the 128-channel HDLC controller M128X and the Memory Timeswitch MTLS as well as an 8-channel interface to the ATM layer. • R E1/T1/J1 FALC 56 PEB 2256 E1/T1/J1 FALCR 56 PEB 2256 MTSL PEB 2047 Memory Time Switch R E1/T1/J1 FALC 56 PEB 2256 Clocks E1/T1/J1 FALCR 56 PEB 2256 Clock Clock MCLK MUNICH128X PEB 20324 PCI/Generic CPU System Bus MEM ITS10714 Figure 2 Data Sheet Multiple E1/T1/J1 Link over Frame Relay 24 2002-08-27 FALC56 V1.2 PEB 2256 Introduction • Port 1 RAM FALC R -56 PEB 2256 E1/T1/J1 8 x PCM UTOPIA IWE8 R PXB 4220 Port 8 E1/T1/J1 FALC R -56 PEB 2256 ATM Layer AAL1 or ATM-Mode ITS10715 Figure 3 Data Sheet 8-Channel E1/T1/J1-Interface to the ATM Layer 25 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions 2 Pin Descriptions 2.1 Pin Diagram P-MQFP-80-1 XPB 60 61 56 52 48 44 VDD VSS A0 A1 A2 A3 A4 A5 A6 A7 ALE RD/DS WR/RW CS BHE/BLE XDI INT VDD VSS XPA (top view) 41 40 D0 XPC D1 XPD D2 SCLKX D3 64 SCLKR 36 D4 RDO VSS RPA VDD RPB D5 68 RPC 32 ® FALC 56 PEB 2256 RPD VDD VSS D6 D7 D8 D9 72 MCLK 28 D10 N.C. D11 RCLK D12 CLK1 VSS 76 CLK2 24 VDD SEC/FSC D13 SYNC D14 Figure 4 Data Sheet N.C. TDO TCK TMS TDI TRS D15 N.C. 21 20 16 RES DBW IM VSS 12 VDD XL1/XDOP/XOID VDDX 8 XL2/XDON VDDR RL1/RDIP/ROID RL2/RDIN/RCLKI 4 VSSX 80 1 VSSR N.C. F0119_1 Pin Configuration P-MQFP-80-1 26 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions 2.2 Pin Diagram P-LBGA-81-1 9 8 7 6 5 4 3 2 1 A XPB XPC SCLKR RPB VDD NC RCLK SYNC VSSR B VSS XPA XPD RDO RPC CLK1 SEC/ FSC NC RL2/ RDIN C BHE/ BLE VDD INT SCLKX VSS MCLK CLK2 RL1/ RDIP XL2/ XDON D CS XDI W R/ RW RPA RPD XL1/ VDDR VDDX XDOP VSSX E ALE A6 RD/DS A7 NC VSS DBW VDD IM F A5 A3 A1 A4 D8 D11 RES TMS TRS G A2 A0 D3 D5 D6 VDD TCK TDO TDI H VSS D0 D2 D4 D9 D12 D13 NC NC J VDD D1 VSS VDD D7 D10 VSS D14 D15 F0119_2 Figure 5 Data Sheet Pin Configuration P-LBGA-81-1 (bottom view) 27 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions 1 2 3 4 5 6 7 8 9 A VSSR SYNC RCLK NC VDD RPB SCLKR XPC XPB B RL2/ RDIN NC SEC/ FSC CLK1 RPC RDO XPD XPA VSS C XL2/ XDON RL1/ RDIP CLK2 MCLK VSS SCLKX INT VDD BHE/ BLE D VSSX VDDX VDDR XL1/ XDOP RPD RPA WR/ RW XDI CS E IM VDD DBW VSS NC A7 RD/DS A6 ALE F TRS TMS RES D11 D8 A4 A1 A3 A5 G TDI TDO TCK VDD D6 D5 D3 A0 A2 H NC NC D13 D12 D9 D4 D2 D0 VSS J D15 D14 VSS D10 D7 VDD VSS D1 VDD F0119_3 Figure 6 Data Sheet Pin Configuration P-LBGA-81-1 (top view) 28 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions 2.3 Pin Definitions and Functions • Table 1 Pin Definitions - Microprocessor Interface Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 50 49 48 47 46 45 44 43 E6 E8 F9 F6 F8 G9 F7 G8 A7 A6 A5 A4 A3 A2 A1 A0 I + PU Address Bus These inputs interface with eight bits of the system’s address bus to select one of the internal registers for read or write. 21 22 23 26 27 28 29 30 31 32 33 36 37 38 39 40 J1 J2 H3 H4 F4 J4 H5 F5 J5 G5 G6 H6 G7 H7 J8 H8 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 I/O + PU Data Bus Bidirectional tristate data lines which interface with the system’s data bus. Their configuration is controlled by the level of pin DBW: 8-bit mode (DBW = 0): D(7:0) are active. D(15:8) are internally pulled high. 16-bit mode (DBW = 1): D(15:0) are active. In case of byte transfers, the active half of the bus is determined by A0 and BHE/BLE and the selected bus interface mode (via pin IM). The unused half is internally pulled high. Data Sheet 29 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 1 Pin Definitions - Microprocessor Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 51 E9 ALE I + PU Address Latch Enable A high on this line indicates an address on an external multiplexed address/data bus. The address information provided on lines A(7:0) is internally latched with the falling edge of ALE. This function allows the FALC®56 to be connected to a multiplexed address/data bus without the need for external latches. In this case, pins A(7:0) must be connected to the data bus pins externally. In case of demultiplexed mode this pin can be connected directly to VDD or can be left open. 52 E7 RD/DS I + PU Read Enable (Intel bus mode) This signal indicates a read operation. When the FALC®56 is selected via CS, the RD signal enables the bus drivers to output data from an internal register addressed by A(7:0) to the Data Bus. Data Strobe (Motorola bus mode) This pin serves as input to control read/write operations. 53 D7 WR/RW I + PU WRite Enable (Intel bus mode) This signal indicates a write operation. When CS is active the FALC®56 loads an internal register with data provided on the data bus. Read/Write Enable (Motorola bus mode) This signal distinguishes between read and write operation. 12 E3 DBW I + PU Data Bus Width (Bus interface mode) A low signal on this input selects the 8-bit bus interface mode. A high signal on this input selects the 16-bit bus interface mode. In this case word transfer to/from the internal registers is enabled. Byte transfers are implemented by using A0 and BHE/BLE. Data Sheet 30 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 1 Pin Definitions - Microprocessor Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 11 E1 IM I + PU Interface Mode The level at this pin defines the bus interface mode: A low signal on this input selects the Intel interface mode. A high signal on this input selects the Motorola interface mode. 54 D9 CS I + PU Chip Select A low signal selects the FALC®56 for read and write operations. This allows to connect multiple devices to a single data/address bus. 55 C9 BHE/ BLE I + PU Bus High Enable (Intel bus mode) If 16-bit bus interface mode is enabled, this signal indicates a data transfer on the upper byte of the data bus D(15:8). In 8-bit bus interface mode this signal has no function and should be tied to VDD or left open. Bus Low Enable (Motorola bus mode) If 16-bit bus interface mode is enabled, this signal indicates a data transfer on the lower byte of the data bus D(7:0). In 8-bit bus interface mode this signal has no function and should be tied to VDD or left open. 57 C7 Data Sheet INT O/oD INTerrupt Request INT serves as general interrupt request for all interrupt sources. These interrupt sources can be masked via registers IMR(5:0). Interrupt status is reported via registers GIS (Global Interrupt Status) and ISR(5:0). Output characteristics (push-pull active low/ high, open drain) are determined by programming register IPC. (oD = open drain output) 31 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions • Table 2 Pin No. Pin Definitions - Line Interface Ball No. Symbol Input (I) Function Output (O) Supply (S) Line Interface Receive 3 C2 RL1 I (analog) Line Receiver 1 Analog input from the external transformer. Selected if LIM1.DRS is cleared. RDIP I Receive Data Input Positive Digital input for received dual-rail PCM(+) route signal which is latched with the internally recovered receive route clock. An internal DPLL extracts the receive route clock from the incoming data pulses. The duty cycle of the received signal has to be close to 50%. The dual-rail mode is selected if LIM1.DRS and FMR0.RC1 are set. Input polarity is selected by bit RC0.RDIS (after reset: active low), line coding is selected by FMR0.RC(1:0). ROID I Receive Optical Interface Data Unipolar data received from a fiber-optical interface with 2048 kbit/s (E1) or 1544 kbit/s (T1/J1). Latching of data is done with the falling edge of RCLKI. Input polarity is selected by bit RC0.RDIS. The single-rail mode is selected if LIM1.DRS is set and FMR0.RC1 is cleared. If CMI coding is selected (FMR0.RC(1:0) = 01), an internal DPLL recovers clock an data; no clock signal on RCLKI is required. Data Sheet 32 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 2 Pin Definitions - Line Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 2 B1 RL2 I (analog) Line Receiver 2 Analog input from the external transformer. Selected if LIM1.DRS is cleared. RDIN I Receive Data Input Negative Input for received dual-rail PCM(-) route signal which is latched with the internally recovered receive route clock. An internal DPLL extracts the receive route clock from the incoming data pulses. The duty cycle of the received signal has to be close to 50%. The dual-rail mode is selected if LIM1.DRS and FMR0.RC1 are set. Input polarity is selected by bit RC0.RDIS (after reset: active low), line coding is selected by FMR0.RC(1:0). RCLKI I Receive Clock Input Receive clock input for the optical interface if LIM1.DRS is set and FMR0.RC(1:0) = 00. Clock frequency: 2.048 MHz (E1) or 1.544 MHz (T1/J1). RCLKI is ignored if CMI coding is selected. Data Sheet 33 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 2 Pin No. Pin Definitions - Line Interface (cont’d) Ball No. Symbol Input (I) Function Output (O) Supply (S) Line Interface Transmit 7 D4 Data Sheet XL1 O (analog) Transmit Line 1 Analog output to the external transformer. Selected if LIM1.DRS is cleared. After reset this pin is in high-impedance state until bit FMR0.XC1 is set and XPM2.XLT is cleared. XDOP O Transmit Data Output Positive This digital output for transmitted dual-rail PCM(+) route signals can provide - half bauded signals with 50% duty cycle (LIM0.XFB = 0) or - full bauded signals with 100% duty cycle (LIM0.XFB = 1) The data is clocked with positive transitions of XCLK in both cases. Output polarity is selected by bit LIM0.XDOS (after reset: active low). The dual-rail mode is selected if LIM1.DRS and FMR0.XC1 are set. After reset this pin is in high-impedance state until register LIM1.DRS is set and XPM2.XLT is cleared. XOID O Transmit Optical Interface Data Unipolar data sent to a fiber-optical interface with 2048 kbit/s (E1) or 1544 kbit/s (T1/J1) which is clocked on the positive transitions of XCLK. Clocking of data in NRZ code is done with 100% duty cycle. Data in CMI code is shifted out with 50% or 100% duty cycle on both transitions of XCLK according to the CMI coding. Output polarity is selected by bit LIM0.XDOS (after reset: data is sent active high). The single-rail mode is selected if LIM1.DRS is set and FMR0.XC1 is cleared. After reset this pin is in high-impedance state until register LIM1.DRS is set and XPM2.XLT is cleared. 34 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 2 Pin Definitions - Line Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 5 C1 XL2 O (analog) Transmit Line 2 Analog output for the external transformer. Selected if LIM1.DRS is cleared. After reset this pin is in high-impedance state until bit FMR0.XC1 is set and XPM2.XLT is cleared. XDON O Transmit Data Output Negative This digital output for transmitted dual-rail PCM(-) route signals can provide - half bauded signals with 50% duty cycle (LIM0.XFB = 0) or - full bauded signals with 100% duty cycle (LIM0.XFB = 1) The data is clocked on positive transitions of XCLK in both cases. Output polarity is selected by bit LIM0.XDOS (after reset: active low). The dual-rail mode is selected if LIM1.DRS and FMR0.XC1 are set. After reset this pin is in high-impedance state until register LIM1.DRS is set and XPM2.XLT cleared. XFM O Transmit Frame Marker This digital output marks the first bit of every frame transmitted on port XDOP. This function is only available in the optical interface mode (LIM1.DRS = 1 and FMR0.XC1 = 0). Data is clocked on positive transitions of XCLK. After reset this pin is in high-impedance state until register LIM1.DRS is set and XPM2.XLT cleared. In remote loop configuration the XFM marker is not valid. Data Sheet 35 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions • Table 3 Pin Definitions - Clock Generation Pin No. Pin No. Symbol Input (I) Function Output (O) Supply (S) 73 C4 MCLK I Master Clock A reference clock of better than ± 32 ppm accuracy in the range of 1.02 to 20 MHz must be provided on this pin. The FALC®56 internally derives all necessary clocks from this master (see registers GCM(6:1)). 79 A2 SYNC I + PU Clock Synchronization of DCO-R If a clock is detected on pin SYNC the DCO-R circuitry of the FALC®56 synchronizes to this 1.544/2.048 MHz clock (see LIM0.MAS, CMR1.DCS and CMR2.DCF). Additionally, in master mode the FALC®56 is able to synchronize to an 8-kHz reference clock (IPC.SSYF = 1). If not connected, an internal pullup transistor ensures high input level. 76 B4 CLK1 O + PU System Clock of DCO-R Output of the de-jittered system clock generated by the DCO-R circuit. Frequency selection is done by setting control bits in PC5/ 6. E1: 16.384 MHz, 8.192 MHz, 4.096 MHz, 2.048 MHz or 8 kHz T1/J1: 16.384 MHz, 12.352 MHz, 8.192 MHz, 6.176 MHz, 4.096 MHz, 3.088 MHz, 2.048 MHz, 1.544 MHz or 8 kHz After reset this output is inactive and internally pulled high. Note: If DCO-R is not active, no clock is output on pin CLK1 (SIC1.RBS(1:0) = 11 and CMR1.RS1 = 0). Data Sheet 36 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 3 Pin Definitions - Clock Generation (cont’d) Pin No. Pin No. Symbol Input (I) Function Output (O) Supply (S) 77 C3 CLK2 O + PU System Clock of DCO-X Output of the de-jittered system clock generated by the DCO-X circuit. Frequency selection is done by setting control bits in PC5/ 6. E1: 16.384 MHz, 8.192 MHz, 4.096 MHz or 2.048 MHz T1/J1: 12.352 MHz, 6.176 MHz, 3.088 MHz or 1.544 MHz After reset this output is inactive and internally pulled high. Note: If DCO-X is not used, no clock is output on pin CLK2 (SIC1.XBS(1:0) = 00 and CMR1.DXJA = 1; buffer bypass and no jitter attenuation) 78 B3 SEC FSC Data Sheet I + PU One-Second Timer Input A pulse with logical high level for at least two 2.048-MHz cycles triggers the internal onesecond timer. After reset this pin is configured to be an input. If not connected, an internal pullup transistor ensures high input level (see register GPC1). O One-Second Timer Output Activated high every second for two 2.048MHz clock cycles. O Optionally an 8-kHz frame synchronization pulse is output via this pin. The synchronization pulse is active high or low for one 2.048/1.544-MHz cycle (pulse width = 488 ns for E1and 648 ns or T1/J1). 37 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 3 Pin Definitions - Clock Generation (cont’d) Pin No. Pin No. Symbol Input (I) Function Output (O) Supply (S) 75 A3 RCLK O + PU Receive Clock After reset this port is configured to be internally pulled up weakly. Setting of bit PC5.CRP switches this port to be an active output. CMR1.RS(1:0) = 00: Receive clock extracted from the incoming data pulses. The clock frequency is 2.048 MHz (E1) or 1.544 MHz (T1/J1). In case of Loss-OfSignal (LOS) the RCLK is derived from the clock that is provided on MCLK. CMR1.RS(1:0) = 01: Receive clock extracted from the incoming data pulses. The clock frequency is 2.048 MHz (E1) or 1.544 MHz (T1/J1). RCLK remains high in case of LOS (indicated by FRS0.LOS = 1). CMR1.RS(1:0) = 10: Dejittered clock generated by the internal DCO-R circuit. The clock frequency is 2.048 MHz (E1 or T1/J1 and SIC2.SSC2 = 0) or 1.544 MHz (T1/J1 and SIC2.SSC2 = 1). CMR1.RS(1:0) = 11: Dejittered clock generated by the internal DCO-R circuit. The clock frequency is 8.192 MHz (E1 or T1/J1 and SIC2.SSC2 = 0) or 6.176 MHz (T1/J1 and SIC2.SSC2 = 1). Data Sheet 38 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions • Table 4 Pin No. Pin Definitions - System Interface Ball No. Symbol Input (I) Function Output (O) Supply (S) System Interface Receive 66 B6 RDO O Receive Data Out Received data that is sent to the system highway. Clocking of data is done with the rising or falling edge (SIC3.RESR) of SCLKR or RCLK, if the receive elastic store is bypassed. The delay between the beginning of time slot 0 and the initial edge of SCLKR (after SYPR goes active) is determined by the values of registers RC1 and RC0. If received data is shifted out with higher (more than 2.048/1.544 Mbit/s) data rates, the active channel phase is defined by bits SIC2.SICS(2:0). During inactive channel phases RDO is cleared (driven to low level, not tristate). 65 A7 SCLKR I/O + PU System Clock Receive Working clock for the receive system interface with a frequency of 16.384/8.192/4.096/2.048 MHz in E1 mode and 16.384/8.192/4.096/ 2.048 MHz (SIC2.SSC2 = 0) or 12.352/6.176/ 3.088/1.544 MHz (SIC2.SSC2 = 1) in T1/J1 mode. If the receive elastic store is bypassed, the clock supplied on this pin is ignored, because RCLK is used to clock the receive system interface. If SCLKR is configured to be an output, the internal working clock of the receive system interface sourced by DCO-R or RCLK is output. Data Sheet 39 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 67 68 69 70 D6 A6 B5 D5 RPA RPB RPC RPD I/O + PU Receive Multifunction Port A to D Depending on programming of bits PC(1:4).RPC(2:0) these multifunction ports carry information to the system interface or from the system to the FALC®56. After reset these ports are configured to be inputs. With the selection of the appropriate pin function, the corresponding input/output configuration is achieved automatically. Depending on bit SIC3.RESR latching/transmission of data is done with the rising or falling edge of SCLKR. If not connected, an internal pullup transistor ensures a high input level. The input function must not be selected twice or more. Selectable pin functions are described below. I + PU Synchronous Pulse Receive (SYPR) PC(4:1).RPC(2:0) = 000 Together with the values of registers RC(1:0) this signal defines the beginning of time slot 0 on system highway port RDO . Only one multifunction port may be selected as SYPR input. After reset, SYPR of port A is used, the other lines are ignored. SYPR cannot be used in combination with RFM. The pulse cycle is an integer multiple of 125 µs. Data Sheet 40 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 67 68 69 70 D6 A6 B5 D5 RPA RPB RPC RPD O Receive Frame Marker (RFM) PC(4:1).RPC(2:0) = 001 CMR2.IRSP = 0: The receive frame marker can be active high for a 2.048-MHz (E1) or 1.544-MHz (T1/J1) period during any bit position of the current frame. It is clocked off with the rising or falling edge of SCLKR or RCLK, depending on SIC3.RESR. Offset programming is done by using registers RC(1:0). CMR2.IRSP = 1: Frame synchronization pulse generated by the DCO-R circuitry internally. Together with registers RC(1:0) the frame begin on the receive system interface is defined. This frame synchronization pulse is active low for a 2.048-MHz (E1) or 1.544-MHz (T1/J1) period. O Receive Multiframe Begin (RMFB) PC(1:4).RPC(2:0) = 010 In E1 mode RMFB marks the beginning of every received multiframe (RDO). Optionally the time slot 16 CAS multiframe begin can be marked (SIC3.CASMF). Active high for one 2.048-MHz period. In T1/J1 mode the function depends on bit XC0.MFBS: MFBS = 1: RMFB marks the beginning of every received multiframe (RDO). MFBS = 0: RMFB marks the beginning of every received superframe. Additional pulses are provided every 12 frames when using ESF/ F24 or F72 format. Data Sheet 41 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 67 68 69 70 D6 A6 B5 D5 RPA RPB RPC RPD O Receive Signaling Marker (RSIGM) PC(1:4).RPC(2:0) = 011 E1: Marks the time slots which are defined by register RTR(4:1) of every received frame on port RDO. T1/J1: Marks the time slots which are defined by register RTR(4:1) of every received frame on port RDO, if CAS-BR is not used. When using the CAS-BR signaling scheme, the robbed bit of each channel every sixth frames is marked, if CAS-BR is enabled by XC0.BRM = 1. O Receive Signaling Data (RSIG) PC(1:4).RPC(2:0) = 100 The received CAS signaling data is sourced by this pin. Time slots on RSIG correlate directly to the time slot assignment on RDO. O Data Link Bit Receive (DLR) PC(1:4).RPC(2:0) = 101 E1: Marks the Sa(8:4)-bits within the data stream on RDO. The Sa(8:4)-bit positions in time slot 0 of every frame not containing the frame alignment signal are selected by register XC0. T1/J1: Marks the DL-bit position within the data stream on RDO. Data Sheet 42 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 67 68 69 70 D6 A6 B5 D5 RPA RPB RPC RPD O Frame Synchronous Pulse (RFSP) PC(1:4).RPC(2:0) = 111 Active low framing pulse derived from the received PCM route signal (line side, RCLK). During loss of synchronization (bit FRS0.LFA = 1), this pulse is suppressed (not influenced during alarm simulation). Pulse frequency: 8 kHz Pulse width: 488 ns (E1) or 648 ns (T1/J1). System Interface Transmit 56 D8 XDI I Transmit Data In Transmit data received from the system highway. Latching of data is done with rising or falling transitions of SCLKX according to bit SIC3.RESX. The delay between the beginning of time slot 0 and the initial edge of SCLKX (after SYPX goes active) is determined by the registers XC(1:0). In higher (more than 1.544/2.048 Mbit/s) data rates sampling of data is defined by bits SIC2.SICS(2:0). 64 C6 SCLKX I + PU System Clock Transmit Working clock for the transmit system interface with a frequency of 16.384/8.192/4.096/2.048 in E1 mode and 16.384/8.192/4.096/2.048 MHz (SIC2.SSC2 = 0) or 12.352/6.176/3.088/ 1.544 MHz (SIC2.SSC2 = 1) in T1/J1 mode. Data Sheet 43 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 60 61 62 63 B8 A9 A8 B7 XPA XPB XPC XPD I/O + PU Transmit Multifunction Port A to D Depending on programming of bits PC(1:4).XPC(3:0) these multifunction ports carry information to the system interface or from the system to the FALC®56. After reset the ports are configured to be inputs. With the selection of the appropriate pin function, the corresponding input/output configuration is achieved automatically. Depending on bit SIC3.RESX latching/transmission of data is done with the rising or falling edge of SCLKX. If not connected, an internal pullup transistor ensures a high input level. Each input function (SYPX, XMFS, XSIG or TCLK) may only be selected once. SYPX and XMFS must not be used in parallel. Selectable pin functions are described below. Data Sheet 44 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 60 61 62 63 B8 A9 A8 B7 XPA XPB XPC XPD I + PU Synchronous Pulse Transmit (SYPX) PC(1:4).XPC(3:0) = 0000 Together with the values of registers XC(0:1) this signal defines the beginning of time slot 0 at system highway port XDI . The pulse cycle is an integer multiple of 125 µs. SYPX must not be used in parallel with XMFS. I + PU Transmit Multiframe Synchronization (XMFS) PC(1:4).XPC(3:0) = 0001 This port defines the frame and multiframe begin on the transmit system interface ports XDI and XSIG. Depending on PC5.CXMFS the signal on XMFS is active high or low. XMFS must not be used in parallel with SYPX. Note: A new multiframe position has settled at least one multiframe after pulse XMFS has been supplied. I + PU Transmit Signaling Data (XSIG) PC(1:4).XPC(3:0) = 0010 Input for transmit signaling data received from the signaling highway. Optionally, (SIC3.TTRF = 1), sampling of XSIG data is controlled by the active high XSIGM marker. At higher data rates sampling of data is defined by bits SIC2.SICS(2:0). Data Sheet 45 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 60 61 62 63 B8 A9 A8 B7 XPA XPB XPC XPD I + PU Transmit Clock (TCLK) PC(1:4).XPC(3:0) = 0011 A 2.048/8.192-MHz (E1) or 1.544/6.176-MHz (T1/J1) clock has to be sourced by the system if the internally generated transmit clock (generated by DCO-X) shall not be used. Optionally this input is used as a synchronization clock for the DCO-X circuitry with a frequency of 2.048 (E1) or 1.544 MHz (T1/J1). O Transmit Multiframe Begin (XMFB) PC(1:4).XPC(3:0) = 0100 XMFB marks the beginning of every transmitted multiframe on XDI. The signal is active high for one 2.048 (E1) or 1.544 MHz (T1/J1) period. O Transmit Signaling Marker (XSIGM) PC(1:4).XPC(3:0) = 0101 E1: Marks the transmit time slots on XDI of every frame which are defined by register TTR(1:4). T1/J1: Marks the transmit time slots on XDI of every frame which are defined by register TTR(1:4) (if not CAS-BR is used). When using the CAS-BR signaling scheme the robbed bit of each channel in every sixth frame is marked. Data Sheet 46 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 4 Pin Definitions - System Interface (cont’d) Pin No. Ball No. Symbol Input (I) Function Output (O) Supply (S) 60 61 62 63 B8 A9 A8 B7 XPA XPB XPC XPD O Data Link Bit Transmit (DLX) PC(1:4).XPC(3:0) = 0110 E1: Marks the Sa(8:4)-bits within the data stream on XDI. The Sa(8:4)-bit positions in time slot 0 of every frame not containing the frame alignment signal are selected by register XC0.SA8E to XC0.SA4E. T1/J1: This output provides a 4-kHz signal which marks the DL-bit position within the data stream on XDI (in ESF mode only). O Transmit Clock (XCLK) PC(1:4).XPC(3:0) = 0111 Transmit line clock of 2.048 MHz (E1) or 1.544 MHz (T1/J1) derived from SCLKX/R, RCLK or generated internally by DCO circuitries. I + PU Transmit Line Tristate (XLT) PC(1:4).XPC(3:0) = 1000 A high level on this port sets the transmit lines XL1/2 or XDOP/N into tristate mode. This pin function is logically ored with register bit XPM2.XLT. Data Sheet 47 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions • Table 5 Pin No. Pin Definitions - Miscellaneous Ball No. Symbol Input (I) Function Output (O) Supply (S) Power Supply 4 D3 VDDR S Positive Power Supply for the analog receiver 1 A1 VSSR S Power Ground for the analog receiver 6 D2 VDDX S Positive Power Supply for the analog transmitter 8 D1 VSSX S Power Ground for the analog transmitter 9 24 34 41 58 71 A5 C8 E2 G4 J6 J9 VDD S Positive Power Supply for the digital subcircuits (3.3 V) For correct operation, all six pins have to be connected to positive power supply. 10 25 35 42 59 72 B9 C5 E4 H9 J3 J7 VSS S Power Ground for digital subcircuits (0 V) For correct operation, all six pins have to be connected to ground. Device Reset 13 F3 Data Sheet RES I Reset A low signal on this pin forces the FALC®56 into reset state. During reset the FALC®56 needs an active clock on pin MCLK. During reset all bidirectional output stages are in input mode, if signal RD is “high” (to disable the data bus output drivers). 48 2002-08-27 FALC56 V1.2 PEB 2256 Pin Descriptions Table 5 Pin No. Pin Definitions - Miscellaneous (cont’d) Ball No. Symbol Input (I) Function Output (O) Supply (S) Unused Pins 19 20 74 80 A4 B2 E5 H1 H2 N.C. not connected, to be left open for compatibility with future products. Boundary Scan/Joint Test Access Group (JTAG) 14 F1 TRS I + PU Test Reset for Boundary Scan (active low). If not connected, an internal pullup transistor ensures high input level. If the JTAG boundary scan is not used, this pin must be connected to RES or VSS. 15 G1 TDI I + PU Test Data Input for Boundary Scan If not connected an internal pullup transistor ensures high input level. 16 F2 TMS I + PU Test Mode Select for Boundary Scan If not connected an internal pullup transistor ensures high input level. 17 G3 TCK I + PU Test Clock for Boundary Scan If not connected an internal pullup transistor ensures high input level. 18 G2 TDO O Test Data Output for Boundary Scan Note: oD = open drain output PU = input or input/output comprising an internal pullup device To override the internal pullup by an external pulldown, a resistor value of 22 kΩ is recommended. The pullup devices are activated during reset, this means their state is undefined until the reset signal has been applied. Unused pins containing pullups can be left open. Data Sheet 49 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 3 Functional Description E1/T1/J1 3.1 Functional Overview The FALC® device contains analog and digital function blocks that are configured and controlled by an external microprocessor or microcontroller. The main interfaces are • • • • Receive and transmit line interface PCM system highway interface/H.100 bus Microprocessor interface Boundary scan interface as well as several control lines for reset and clocking purpose. The main internal functional blocks are • • • • • • • • • • • • Analog line receiver with equalizer network and clock/data recovery Analog line driver with programmable pulse shaper and line build out Central clock generation module Elastic buffers for receive and transmit direction Receive Framer, receive line decoding, alarm detection, PRBS and performance monitoring Transmit framer, receive line encoding, alarm and PRBS generation Receive jitter attenuator Transmit jitter attenuator Three HDLC controllers (one of them including SS7 and BOM support) and CAS signaling controller Test functions (loop switching local - remote - payload - single channel) Register access interface Boundary scan control Data Sheet 50 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 3.2 Block Diagram • RCLK Receive Jitter Attenuator Remote Loop + JATT Long+Short Haul Line Interface Local Loop Clock/Data Recovery XL1/XDOP/ XOID XL2/XDON/ XFM Receive Framer Alarm Detector PRBS Monitor Line Decoder Perform. Monitor. Signaling Controller CAS-CC CAS-BR Frame Gen. Alarm Gen. PRBS Generator Line Coding Long + Short Haul Transmit Line Interface Receive Elastic Buffer or Bypass RDO RPA RPB RPC RPD Receive Backplane Interface Payload Loop RL1/RDIP/ ROID RL2/RDIN/ RCLKI SCLKR HDLC/ BOM/SS7 Controller Transmit Elastic Buffer or Bypass XDI XPA XPB XPC XPD Transmit Backplane Interface SCLKX Transmit Jitter Attenuator TCLK RCLK RCLK TCLK SCLKX Microprocessor Interface Intel/Motorola Boundary Scan JTAG 1149 TDI TMS TCK TRS TDO D0...15 A0...7 CS Figure 7 Data Sheet WR/RW ALE IM RES DBW INT RD/DS BHE/BLE Clocking Unit MCLK SYNC SEC/FSC ITS10825 Block Diagram 51 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 3.3 Functional Blocks 3.3.1 Microprocessor Interface The communication between the CPU and the FALC56 is done using a set of directly accessible registers. The interface can be configured as Intel or Motorola type with a selectable data bus width of 8 or 16 bits. The CPU transfers data to and from the FALC56 (through 64-byte deep FIFOs per direction), sets the operating modes, controls function sequences, and gets status information by writing or reading control and status registers. All accesses can be done as byte or word accesses if enabled. If 16-bit bus width is selected, access to lower/ upper part of the data bus is determined by address line A0 and signal BHE/BLE as shown in Table 6 and Table 7. Table 8 shows how the ALE (Address Latch Enable) line is used to control the bus structure and interface type. The switching of ALE allows the FALC56 to be directly connected to a multiplexed address/data bus. 3.3.1.1 Mixed Byte/Word Access to the FIFOs Reading from or writing to the internal FIFOs (RFIFO and XFIFO) can be done using a 8-bit (byte) or 16-bit (word) access depending on the selected bus interface mode. Randomly mixed byte/word access to the FIFOs is allowed without any restrictions. Table 6 Data Bus Access (16-Bit Intel Mode) BHE A0 Register Access FALC56 Data Pins Used 0 0 FIFO word access Register word access (even addresses) D(15:0) 0 1 Register byte access (odd addresses) D(15:8) 1 0 Register byte access (even addresses) D(7:0) 1 1 No transfer performed None Table 7 Data Bus Access (16-Bit Motorola Mode) BLE A0 Register Access FALC56 Data Pins Used 0 0 FIFO word access Register word access (even addresses) D(15:0) 0 1 Register byte access (odd addresses) D(7:0) 1 0 Register byte access (even addresses) D(15:8) 1 1 No transfer performed None Data Sheet 52 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 Table 8 Selectable Bus and Microprocessor Interface Configuration ALE IM Microprocessor interface Bus Structure VSS/VDD 1 Motorola de-multiplexed VSS/VDD 0 Intel de-multiplexed switching 0 Intel multiplexed The assignment of registers with even/odd addresses to the data lines in case of 16-bit register access depends on the selected microprocessor interface mode: Intel (Address n + 1) (Address n) Motorola (Address n) (Address n + 1) ↑ ↓ Data Lines D15 ↑ ↓ D8 D7 D0 n: even address 3.3.1.2 FIFO Structure In transmit and receive direction of the signaling controller 64-byte deep FIFOs are provided for the intermediate storage of data between the system internal highway and the CPU interface. The FIFOs are divided into two halves of 32 bytes. Only one half is accessible to the CPU at any time. In case 16-bit data bus width is selected by fixing pin DBW to logical 1 word access to the FIFOs is enabled. Data output to bus lines D(15:0) as a function of the selected interface mode is shown in Figure 8 and Figure 9. Of course, byte access is also allowed. The effective length of the accessible part of RFIFO can be changed from 32 bytes (reset value) down to 2 bytes. Data Sheet 53 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 RFIFO XFIFO 32 32 1 1 32 Byte 32 32 Byte 32 4 Byte 4 4 Byte 4 3 Byte 3 3 Byte 3 2 Byte 2 2 Byte 2 1 Byte 1 1 Byte 1 D15 D8 D7 D0 D15 D8 D7 D0 F0112 Figure 8 FIFO Word Access (Intel Mode) RFIFO D15 XFIFO 32 32 1 1 32 Byte 32 32 Byte 32 4 Byte 4 4 Byte 4 3 Byte 3 3 Byte 3 2 Byte 2 2 Byte 2 1 Byte 1 1 Byte 1 D8 D7 D0 D15 D8 D7 D0 F0113 Figure 9 Data Sheet FIFO Word Access (Motorola Mode) 54 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 3.3.1.3 Interrupt Interface Special events in the FALC® are indicated by means of a single interrupt output with programmable characteristics (open drain or push-pull, defined by register IPC), which requests the CPU to read status information from the FALC®, or to transfer data from/to the FALC®. Since only one INT request output is provided, the cause of an interrupt must be determined by the CPU by reading the FALC®’s interrupt status registers (GIS, ISR(5:0)). The interrupt on pin INT and the interrupt status bits are reset by reading the interrupt status registers. Register ISR(5:0) are of type “clear on read“. The structure of the interrupt status registers is shown in Figure 10. Global Interrupt Status Register GIS ISR0 ISR0 IMR0 ISR1 ISR2 ISR1 ISR2 IMR1 IMR2 ISR3 ISR4 ISR3 ISR4 IMR3 IMR4 ISR5 ISR5 IMR5 F0127 V1.0 Figure 10 Interrupt Status Registers Each interrupt indication of registers ISR(5:0) can be selectively masked by setting the corresponding bit in the corresponding mask registers IMR(5:0). If the interrupt status bits are masked they neither generate an interrupt at INT nor are they visible in ISR(5:0). GIS, the non-maskable Global Interrupt Status Register, serves as pointer to pending interrupts. After the FALC® has requested an interrupt by activating its INT pin, the CPU should first read the Global Interrupt Status register GIS to identify the requesting Data Sheet 55 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 interrupt source register. After reading the assigned interrupt status registers ISR(5:0), the pointer in register GIS is cleared or updated if another interrupt requires service. If all pending interrupts are acknowledged by reading (GIS is reset), pin INT goes inactive. Updating of interrupt status registers ISR(5:0) and GIS is only prohibited during read access. Masked Interrupts Visible in Status Registers • The Global Interrupt Status register (GIS) indicates those interrupt status registers with active interrupt indications (GIS.ISR(5:0)). • An additional mode can be selected via bit GCR.VIS. • In this mode, masked interrupt status bits neither generate an interrupt on pin INT nor are they visible in GIS, but are displayed in the corresponding interrupt status register(s) ISR(5:0). This mode is useful when some interrupt status bits are to be polled in the individual interrupt status registers. Note: In the visible mode, all active interrupt status bits, whether the corresponding actual interrupt is masked or not, are reset when the interrupt status register is read. Thus, when polling of some interrupt status bits is desired, care must be taken that unmasked interrupts are not lost in the process. Note: All unmasked interrupt statuses are treated as before. Please note that whenever polling is used, all interrupt status registers concerned have to be polled individually (no “hierarchical” polling possible), since GIS only contains information on actually generated, i.e. unmasked interrupts. Data Sheet 56 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 3.3.2 Boundary Scan Interface In the FALC56 a Test Access Port (TAP) controller is implemented. The essential part of the TAP is a finite state machine (16 states) controlling the different operational modes of the boundary scan. Both, TAP controller and boundary scan, meet the requirements given by the JTAG standard IEEE 1149.1. Figure 11 gives an overview. TMS TDI clock Clock Generation Reset test control BD data in TAP Controller data in enable finite state machine instruction register test signal generator TDO control bus 1 2 Boundary Scan (n bits) TCK TAP controller reset Identification Register (32 bits) TRS n ID data out data out BD data out F0115 Figure 11 Block Diagram of Test Access Port and Boundary Scan After switching on the device (power-on), a reset signal has to be applied to TRS, which forces the TAP controller into test logic reset state. For normal operation without boundary scan access, the boundary reset pin TRS can be tied to the device reset pin RES. The boundary length is 129. Data Sheet 57 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 If no boundary scan operation is used, TRS has to be connected to RST or VSS. TMS, TCK and TDI do not need to be connected since pullup transistors ensure high input levels in this case. Test handling (boundary scan operation) is performed using the pins TCK (Test Clock), TMS (Test Mode Select), TDI (Test Data Input) and TDO (Test Data Output) when the TAP controller is not in its reset state, that means TRS is connected to VDD or it remains unconnected due to its internal pull up. Test data at TDI is loaded with a clock signal connected to TCK. "1" or "0" on TMS causes a transition from one controller state to another; constant "1" on TMS leads to normal operation of the chip. An input pin (I) uses one boundary scan cell (data in), an output pin (O) uses two cells (data out and enable) and an I/O-pin (I/O) uses three cells (data in, data out and enable). Note that most functional output and input pins of the FALC56 are tested as I/O pins in boundary scan, hence using three cells. The desired test mode is selected by serially loading a 8-bit instruction code into the instruction register through TDI (LSB first). EXTEST is used to examine the interconnection of the devices on the board. In this test mode at first all input pins capture the current level on the corresponding external interconnection line, whereas all output pins are held at constant values ("0" or "1"). Then the contents of the boundary scan is shifted to TDO. At the same time the next scan vector is loaded from TDI. Subsequently all output pins are updated according to the new boundary scan contents and all input pins again capture the current external level afterwards, and so on. SAMPLE is a test mode which provides a snapshot of pin levels during normal operation. IDCODE: A 32-bit identification register is serially read out on pin TDO. It contains the version number (4 bits), the device code (16 bits) and the manufacturer code (11 bits). The LSB is fixed to "1". The ID code field is set to: 0001 0000 0000 0101 1001 0000 1000 0011 Version = 3H, Part Number = 0059H, Manufacturer = 083H (including LSB, fixed to "1") BYPASS: A bit entering TDI is shifted to TDO after one TCK clock cycle. An alphabetical overview of all TAP controller operation codes is given in Table 9. Table 9 TAP Controller Instruction Codes TAP Instruction Instruction Code BYPASS 11111111 EXTEST 00000000 IDCODE 00000100 SAMPLE 00000001 reserved for device test 01010011 Data Sheet 58 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1/T1/J1 3.3.3 Master Clocking Unit The FALC56 provides a flexible clocking unit, which references to any clock in the range of 1.02 to 20 MHz supplied on pin MCLK. The clocking unit has to be tuned to the selected reference frequency by setting the global clock mode registers GCM(6:1) accordingly. The calculation formulas for the appropriate register settings can be found in Chapter 9.2 on page 217 or Chapter 10.2 on page 334. A calculation tool is available to evaluate the required register settings automatically (see Chapter 13.3 on page 481). All required clocks for E1 or T1/J1 operation are generated by this circuit internally. The global setting depends only on the selected master clock frequency and is the same for E1 and T1/J1 because both clock rates are provided simultaneously. To meet the E1 requirements the MCLK reference clock must have an accuracy of better than ± 32 ppm. The synthesized clock can be controlled on pins CLK1, CLK2, RCLK, SCLKR and XCLK. . E1 Clocks MCLK Flexible Master Clock Unit T1 / J1 Clocks GCM1...GCM6 F0116 Figure 12 Data Sheet Flexible Master Clock Unit 59 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4 Functional Description E1 4.1 Receive Path in E1 Mode RL1/RDIP/ROID RL2/RDIN/RCLKI Clock & Data Recovery DPLL Equalizer Analog LOS Detector Line Decoder Alarm Detector DCO-R Receive Jitter Attenuator SYNC RDATA RCLK Receive System Interface FSC F0117 MCLK Figure 13 4.1.1 Receive Clock System (E1) Receive Line Interface For data input, three different data types are supported: • Ternary coded signals received at multifunction ports RL1 and RL2 from a -10 dB (short-haul, LIM0.EQON = 0) or -43 dB (long-haul, LIM0.EQON = 1) ternary interface. The ternary interface is selected if LIM1.DRS is reset. • Digital dual-rail signals received on ports RDIP and RDIN. The dual-rail interface is selected if LIM1.DRS and FMR0.RC1 is set. • Unipolar data on port ROID received from a fiber-optical interface. The optical interface is selected if LIM1.DRS is set and FMR0.RC1 is reset. 4.1.2 Receive Short and Long-Haul Interface The FALC56 has an integrated short-haul and long-haul line interface, including a receive equalization network and noise filtering. Data Sheet 60 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.1.3 Receive Equalization Network (E1) The FALC56 automatically recovers the signals received on pins RL1/2 in a range of up to -43 dB. The maximum reachable length with a 22 AWG twisted pair cable is 1500 m. After reset the FALC56 is in short-haul“ mode, received signals are recovered up to -10 dB of cable attenuation. Switching in Long-haul“ mode is done by setting of bit LIM0.EQON. The integrated receive equalization network recovers signals with up to -43 dB of cable attenuation. Noise filters eliminate the higher frequency part of the received signals. The incoming data is peak-detected and sliced to produce the digital data stream. The slicing level is software selectable in four steps (45%, 50%, 55%, 67%). For typical E1 applications, a level of 50% is used. The received data is then forwarded to the clock & data recovery unit. In long-haul mode, the current equalizer status is indicated by register RES (Receive Equalizer Status). 4.1.4 Receive Line Attenuation Indication (E1) Status register RES reports the current receive line attenuation in a range from 0 to -43 dB in 25 steps of approximately 1.7 dB each. The least significant 5 bits of this register indicate the cable attenuation in dB. These 5 bits are only valid in combination with the most significant two bits (RES.EV1/0 = 01). 4.1.5 Receive Clock and Data Recovery (E1) The analog received signal on port RL1/2 is equalized and then peak-detected to produce a digital signal. The digital received signal on port RDIP/N is directly forwarded to the DPLL. The receive clock and data recovery extracts the route clock from the data stream received at the RL1/2, RDIP/RDIN or ROID lines and converts the data stream into a single-rail, unipolar bit stream. The clock and data recovery uses an internally generated high frequency clock based on MCLK. The recovered route clock or a de-jittered clock can be output on pin RCLK as shown in Table 10. See also Table 13 on page 67 for details of master/slave clocking. Data Sheet 61 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Table 10 RCLK Output Selection (E1) Clock Source RCLK Frequency CMR1. DCS CMR1. RS1/0 Receive Data (2.048 Mbit/s on RL1/RL2, RDIP/ RDIN or ROID) 2.048 MHz (recovered clock) X 00 Receive Data in case of LOS constant high 0 01 2.048 MHz (generated by DCO-R, synchronized on SYNC) 1 10 DCO-R 2.048 MHz X 10 8.192 MHz X 11 The intrinsic jitter generated in the absence of any input jitter is not more than 0.035 UI. In digital bipolar line interface mode the clock and data recovery requires HDB3 coded signals with 50% duty cycle. 4.1.6 Receive Line Coding (E1) The HDB3 line code or the AMI coding is provided for the data received from the ternary or the dual-rail interface. In case of the optical interface a selection between the NRZ code and the CMI Code (1T2B) with HDB3 or AMI postprocessing is provided. If CMI code is selected the receive route clock is recovered from the data stream. The CMI decoder does not correct any errors. In case of NRZ coding data is latched with the falling edge of signal RCLKI. The HDB3 code is used along with double violation detection or extended code violation detection (selectable by FMR0.EXZE)). In AMI code all code violations are detected. The detected errors increment the code violation counter (16 bits length). When using the optical interface with NRZ coding, the decoder is bypassed and no code violations are detected. The signal at the ternary interface is received at both ends of a transformer. The E1 operating modes 75 Ω or 120 Ω are selectable by switching resistors in parallel or using special transformers with different transfer ratios in one package (using center tap). This selection does not require changing transformers. Data Sheet 62 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 RL1 Line t2 t1 R R2 FALC RL2 ITS10967 Figure 14 Receiver Configuration (E1) Table 11 Recommended Receiver Configuration Values (E1) Characteristic Impedance [Ω] Parameter1) R2 (± 1%) [Ω] t2 : t1 1) 120 75 120 75 1:1 1:1 This includes all parasitic effects caused by circuit board design. 4.1.7 Receive Line Monitoring Mode For short-haul applications like shown in Figure 15, the receive equalizer can be switched into receive line monitoring mode (LIM0.RLM = 1). One device is used as a short-haul receiver while the other is used as a short-haul monitor. In this mode the receiver sensitivity is increased to detect an incoming signal of -20 dB resistive attenuation. The required resistor values are given in Table 12. Data Sheet 63 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 t2 : t1 RL1 E1/T1/J1 Receive Line FALC® (Receiver) R1 RL2 LIM0.RLM=0 R3 R3 t2 : t1 RL1 FALC® (Monitor) R2 RL2 resistive -20 dB network LIM0.RLM=1 F0074 Figure 15 Receive Line Monitoring Table 12 External Component Recommendations (Monitoring) Parameter1) Characteristic Impedance [Ω] E1 R1 (± 1 %) [Ω] R2 (± 1 %) [Ω] R3 (± 1 %) [Ω] t2 : t1 1) 75 120 75 120 75 120 330 510 1:1 1:1 This includes all parasitic effects caused by circuit board design. Using the receive line monitor mode and the hardware tristate function of transmit lines XL1/2, the FALC56 now supports applications connecting two devices to one receive and transmission line. In these kind of applications both devices are working in parallel for redundancy purpose (see Figure 16). While one of them is driving the line, the other one must be switched into transmit line tristate mode. If both channels are configured identically and supplied with the same system data and clocks, the transmit path can be switched from one channel to the other without causing a synchronization loss at the remote end. Data Sheet 64 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 XL1 E1/T1/J1 Transmit Line XDI XL2 RL1 FALC® (active) E1/T1/J1 Receive Line RDO RL2 TRIST 1 XL1 XDI XL2 RL1 FALC® (stand by) RDO RL2 TRIST F0075 Figure 16 4.1.8 Protection Switching Application Loss-of-Signal Detection (E1) There are different definitions for detecting Loss-Of-Signal (LOS) alarms in the ITU-T G.775 and ETS 300233. The FALC56 covers all these standards. The LOS indication is performed by generating an interrupt (if not masked) and activating a status bit. Additionally a LOS status change interrupt is programmable by using register GCR.SCI. • Detection: An alarm is generated if the incoming data stream has no pulses (no transitions) for a certain number (N) of consecutive pulse periods. “No pulse” in the digital receive interface means a logical zero on pins RDIP/RDIN/ROID. A pulse with an amplitude less than Q dB below nominal is the criteria for “no pulse” in the analog receive interface (LIM1.DRS = 0). The receive signal level Q is programmable by three control Data Sheet 65 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 bits LIM1.RIL(2:0) (see Chapter 11.3 on page 447). The number N can be set by an 8-bit register (PCD). The contents of the PCD register is multiplied by 16, which results in the number of pulse periods, i.e. the time which has to suspend until the alarm has to be detected. The programmable range is 16 to 4096 pulse periods. ETS300233 requires detection intervals of at least 1 ms. This time period results always in a LFA (Loss of Frame Alignment) before a LOS is detected. • Recovery: In general the recovery procedure starts after detecting a logical one (digital receive interface) or a pulse (analog receive interface) with an amplitude more than Q dB (defined by LIM1.RIL(2:0)) of the nominal pulse. The value in the 8-bit register PCR defines the number of pulses (1 to 255) to clear the LOS alarm. If a loss-of-signal condition is detected in long-haul mode, the data stream can optionally be cleared automatically to avoid bit errors before LOS is indicated. The selection is done by LIM1.CLOS = 1. 4.1.9 Receive Jitter Attenuator (E1) The receive jitter attenuator is placed in the receive path. The working clock is an internally generated high frequency clock based on the clock provided on pin MCLK. The jitter attenuator meets the requirements of ITU-T I.431, G. 736 to 739, G.823 and ETSI TBR12/13. The internal PLL circuitry DCO-R generates a "jitter-free" output clock which is directly dependent on the phase difference of the incoming clock and the jitter attenuated clock.The receive jitter attenuator can be synchronized either on the extracted receive clock RCLK or on a 2.048-MHz/8-kHz clock provided on pin SYNC (8 kHz in master mode only). The received data is written into the receive elastic buffer with RCLK and are read out with the de-jittered clock sourced by DCO-R. The jitter attenuated clock can be output on pins RCLK, CLK1 or SCLKR. Optionally an 8-kHz clock is provided on pin SEC⁄FSC. The DCO-R circuitry attenuates the incoming jittered clock starting at 2-Hz jitter frequency with 20 dB per decade fall-off. Wander with a jitter frequency below 2 Hz is passed unattenuated. The intrinsic jitter in the absence of any input jitter is < 0.02 UI. For some applications it might be useful starting of jitter attenuation at lower frequencies. Therefore the corner frequency is switchable by the factor of ten down to 0.2 Hz (LIM2.SCF). The DCO-R circuitry is automatically centered to the nominal bit rate if the reference clock on pin SYNC/RCLK is missed for 2, 3 or 4 of the 2.048-MHz clock periods. This center function of DCO-R can be disabled (CMR2.DCF = 1) in order to accept a gapped reference clock. In analog line interface mode RCLK is always running. Only in digital line interface mode with single-rail data a gapped clock can occur. The receive jitter attenuator works in two different modes: Data Sheet 66 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 • Slave mode In slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the recovered route clock. In case of LOS the DCO-R switches automatically to Master mode. If bit CMR1.DCS is set automatic switching from RCLK to SYNC is disabled. • Master mode In master mode (LIM0.MAS = 1) the jitter attenuator is in free running mode if no clock is supplied on pin SYNC. If an external clock on the SYNC input is applied, the DCO-R synchronizes to this input. The external frequency can be 2.048 MHz (IPC.SSYF = 0) or 8.0 kHz (IPC.SSYF = 1). The following table shows the clock modes with the corresponding synchronization sources. Table 13 System Clocking (E1) Mode Internal SYNC LOS Active Input System Clocks generated by DCO-R Master independent Fixed to VDD DCO-R centered, if CMR2.DCF = 0. (CMR2.DCF should not be set) Master independent 2.048 MHz Synchronized to SYNC input (external 2.048 MHz, IPC.SSYF = 0) Master independent 8.0 kHz Synchronized to SYNC input (external 8.0 kHz, IPC.SSYF = 1, CMR2.DCF = 0) Slave no Fixed to VDD Synchronized to line RCLK Slave no 2.048 MHz Synchronized to line RCLK Slave yes Fixed to VDD CMR1.DCS = 0: DCO-R is centered, if CMR2.DCF = 0. (CMR2.DCF should not be set) CMR1.DCS = 1: Synchronized on line RCLK Slave yes 2.048 MHz CMR1.DCS = 0: Synchronized to SYNC input (external 2.048 MHz) CMR1.DCS = 1: Synchronized on line clock RCLK The jitter attenuator meets the jitter transfer requirements of the ITU-T I.431 and G.735 to 739 (refer to Figure 17) Data Sheet 67 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 . ITD10312 10 dB ITU G.736 Template R FALC 0 Attenuation -10 -20 -30 -40 -50 -60 1 10 100 1000 10000 Hz 100000 Frequency Figure 17 Jitter Attenuation Performance (E1) Also the requirements of ETSI TBR12/13 are satisfied. Insuring adequate margin against TBR12/13 output jitter limit with 15 UI input at 20 Hz the DCO-R circuitry starts jitter attenuation at about 2 Hz. Data Sheet 68 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.1.10 Jitter Tolerance (E1) The FALC56 receiver’s tolerance to input jitter complies with ITU for CEPT applications. Figure 18 shows the curves of different input jitter specifications stated below as well as the FALC56 performance. 1000 PUB 62411 TR-NWT 000499 Cat II CCITT G.823 ITU-T I.431 FALC® UI Jitter Amplitude 100 10 1 0.1 1 10 100 1000 10000 Hz Jitter Frequency Figure 18 4.1.11 100000 F0025 Jitter Tolerance (E1) Output Jitter (E1) In the absence of any input jitter the FALC56 generates the output jitter, which is specified in theTable 14 below. Table 14 Specification ITU-T I.431 ETSI TBR 12 Data Sheet Output Jitter (E1) Measurement Filter Bandwidth Lower Cutoff Upper Cutoff Output Jitter (UI peak to peak) 20 Hz 100 kHz < 0.015 700 Hz 100 kHz < 0.015 40 Hz 100 kHz < 0.11 69 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.1.12 Framer/Synchronizer (E1) The following functions are performed: • Synchronization on pulse frame and multiframe • Error indication when synchronization is lost. In this case, AIS is sent automatically to the system side and remote alarm is sent to the remote end if enabled. • Initiating and controlling of resynchronization after reaching the asynchronous state. This can be done automatically by the FALC56 or user controlled using the microprocessor interface. • Detection of remote alarm indication from the incoming data stream. • Separation of service bits and data link bits. This information is stored in status registers. • Generation of various maskable interrupt statuses of the receiver functions. • Generation of control signals to synchronize the CRC checker, and the receive elastic buffer. If programmed and applicable to the selected multiframe format, CRC checking of the incoming data stream is done by generating check bits for a CRC submultiframe according to the CRC4 procedure (refer to ITU-T G.704). These bits are compared with those check bits that are received during the next CRC submultiframe. If there is at least one mismatch, the CRC error counter (16 bit) is incremented. 4.1.13 Receive Elastic Buffer (E1) The received bit stream is stored in the receive elastic buffer. The memory is organized as a two-frame elastic buffer with a maximum size of 64 × 8 bit. The size of the elastic buffer can be configured independently for the receive and transmit direction. Programming of the receive buffer size is done by SIC1.RBS1/0: • RBS1/0 = 00: two frame buffer or 512 bits Maximum of wander amplitude (peak-to-peak): 190 UI (1 UI = 488 ns) average delay after performing a slip: 1 frame or 256 bits • RBS1/0 = 01: one frame buffer or 256 bits Maximum of wander amplitude: 100 UI average delay after performing a slip: 128 bits, (SYPR = output) • RBS1/0 = 10: short buffer or 96 bits Maximum of wander amplitude: 38 UI average delay after performing a slip: 48 bits, (SYPR = output) • RBS1/0 = 11: Bypass of the receive elastic buffer The functions are: • Clock adaption between system clock (SCLKR) and internally generated route clock (RCLK). • Compensation of input wander and jitter. Data Sheet 70 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 • Frame alignment between system frame and receive route frame • Reporting and controlling of slips Controlled by special signals generated by the receiver, the unipolar bit stream is converted into bit-parallel data which is circularly written to the elastic buffer using internally generated receive route clock (RCLK). Reading of stored data is controlled by the system clock sourced by SCLKR or by the receive jitter attenuator and the synchronization pulse (SYPR) together with the programmed offset values for the receive time slot/clock slot counters. After conversion into a serial data stream, the data is given out on port RDO. If the receive buffer is bypassed programming of the time slot offset is disabled and data is clocked off with RCLK instead of SCLKR. In one frame or short buffer mode the delay through the receive buffer is reduced to an average delay of 128 or 46 bits. In bypass mode the time slot assigner is disabled. In this case SYPR programmed as input is ignored. Slips are performed in all buffer modes except the bypass mode. After a slip is detected the read pointer is adjusted to one half of the current buffer size. The following table gives an overview of the receive buffer operating mode. I Table 15 Receive Buffer Operating Modes (E1) Buffer Size (SIC1.RBS1/0) TS Offset programming (RC1/0) + SYPR = input Slip performance bypass1) disabled recommended: SYPR = output no short buffer not recommended, recommended: SYPR = output yes 1 frame not recommended, recommended: SYPR = output yes 2 frames enabled yes 1) In bypass mode the clock provided on pin SCLKR is ignored. Clocking is done with RCLK. In single frame mode (SIC1.RBS), values of receive time slot offset (RC1/0) have to be specified great enough to prevent too great approach of frame begin of line side and frame begin of system side. Figure 19 gives an idea of operation of the receive elastic buffer: A slip condition is detected when the write pointer (W) and the read pointer (R) of the memory are nearly coincident, i.e. the read pointer is within the slip limits (S +, S –). If a Data Sheet 71 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 slip condition is detected, a negative slip (one frame or one half of the current buffer size is skipped) or a positive slip (one frame or one half of the current buffer size is read out twice) is performed at the system interface, depending on the difference between RCLK and the current working clock of the receive backplane interface. I.e. on the position of pointer R and W within the memory. A positive/negative slip is indicated in the interrupt status bits ISR3.RSP and ISR3.RSN. Frame 2 Time Slots R’ R Slip S- S+ W Frame 1 Time Slots Moment of Slip Detection W : Write Pointer (Route Clock controlled) R : Read Pointer (System Clock controlled) S+, S- : Limits for Slip Detection (mode dependent) ITD10952 Figure 19 Data Sheet The Receive Elastic Buffer as Circularly Organized Memory 72 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.1.14 Receive Signaling Controller (E1) The signaling controller can be programmed to operate in various signaling modes. The FALC56 performs the following signaling and data link methods. 4.1.14.1 HDLC or LAPD access The FALC56 offers three independent HDLC channels. All of them provide the following features: • 64 byte receive FIFO for each channel • 64 byte transmit FIFO for each channel • transmission in one of 31 time slots (time slot number programmable for each channel individually) • transmission in even frames only, odd frames only or both (programmable for each channel individually) • bit positions to be used in selected time slots are maskable (any bit position can be enabled for each channel individually) • HDLC or transparent mode • flag detection • CRC checking • bit-stuffing • flexible address recognition (1 byte, 2 bytes) • C/R-bit processing (according to LAPD protocol) In addition to this, HDLC channel 1 provides: • • • • • SS7 support BOM (bit oriented message) support use of time slot 0 (up to 32 time slots) use of Sa-bits flexibility to insert and extract data during certain time slots, any combination of time slots can be programmed independently for the receive and transmit direction In case of common channel signaling the signaling procedure HDLC/SDLC or LAPD according to Q.921 is supported. The signaling controller of the FALC56 performs the flag detection, CRC checking, address comparison and zero-bit removing. The received data flow and the address recognition features can be performed in very flexible way, to satisfy almost any practical requirements. Depending on the selected address mode, the FALC56 performs a 1 or 2-byte address recognition. If a 2-byte address field is selected, the high address byte is compared with the fixed value FEH or FCH (group address) as well as with two individually programmable values in RAH1 and RAH2 registers. According to the ISDN LAPD protocol, bit 1 of the high byte address is interpreted as command/response bit (C/R) and is excluded from the address comparison. Buffering of receive data is done in a 64 byte deep RFIFO. Data Sheet 73 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 In signaling controller transparent mode, fully transparent data reception without HDLC framing is performed, i.e. without flag recognition, CRC checking or bit stuffing. This allows user specific protocol variations. 4.1.14.2 Support of Signaling System #7 The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is described in ITU-Q.703. The following description assumes, that the reader is familiar with the SS7 protocol definition. SS7 support must be activated by setting the MODE register. The SS7 protocol is supported by the following hardware features in receive mode: • • • • • all Signaling Units (SU) are stored in the receive FIFO (RFIFO) detecting of flags from the incoming data stream bit stuffing (zero deletion) checking of seven or more consecutive ones in the receive data stream checking if the received Signaling Unit is a multiple of eight bits and at least six octets including the opening flag • calculation of the CRC16 checksum: In receive direction the calculated checksum is compared to the received one; errors are reported in register RSIS. • checking if the signal information field of a received signaling unit consists of more than 272 octets, in this case the current signaling unit is discarded. In order to reduce the microprocessor load, fill In signaling units (FISUs) are processed automatically. By examining the length indicator of a received signal unit the FALC56 decides whether a FISU has been received. Consecutively received FISUs are compared and optionally not stored in the receive FIFO (RFIFO, 2×32 bytes), if the contents is equal to the previous one. The same applies to link status signaling units, if bit CCR5.CSF is set. The different types of signaling units as message signaling unit (MSU), link status signaling unit (LSSU) and fill in signaling units (FISU) are indicated in the RSIS register, which is automatically added to the RFIFO with each received signaling unit. The complete signaling unit except start and end flags is stored in the receive FIFO. The functions of bits CCR1.RCRC and CCR1.RADD are still valid in SS7 mode. Errored signaling units are handled automatically according to ITU-T Q.703 as shown in Figure 20. SU counter (su) and errored SU counter (Cs) are reset by setting CMDR2.RSUC. The error threshold T can be selected to be 64 (default) or 32 by setting/ clearing bit CCR5.SUET. If the defined error limit is exceeded, an interrupt (ISR1.SUEX) is generated, if not masked by IMR1.SUEX = 1. Note: If SUEX is caused by an aborted/invalid frame, the interrupt will be issued regularly until a valid frame is received (e.g. a FISU). Data Sheet 74 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Idle Reset Counter values Cs := 0 su := 0 [CMDR2.RSUC = 1] in service N SU in error? Y Cs := Cs + 1 su := su + 1 Cs = T ? su := su + 1 N N Y su = 256 ? Y Link failure [ISR1.SUEX = 1] su := 0 Idle Cs = 0 ? Y N Notes: su: signaling units counter Cs: errored signaling units counter T: error threshold (64 or 32), selectable by CCR5.SUET Figure 20 Data Sheet Cs := Cs -1 in service F0071 Automatic Handling of Errored Signaling Units 75 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.1.14.3 Sa-Bit Access (E1) The FALC56 supports the Sa-bit signaling of time slot 0 of every other frame as follows: • the access through register RSW • the access through registers RSA(8:4), capable of storing the information for a complete multiframe • the access through the 64 byte deep receive FIFO of the signaling controller of HDLC channel 1. This Sa-bit access gives the opportunity to receive a transparent bit stream as well as HDLC frames where the signaling controller automatically processes the HDLC protocol. Any combination of Sa-bits which shall be extracted and stored in the RFIFO is selected by XC0.SA(8:4). The access to the RFIFO is supported by ISR0.RME/RPF. 4.1.14.4 Channel Associated Signaling CAS (E1, serial mode) The signaling information is carried in time slot 16 (TS16). The signaling controller samples the bit stream either on the receive line side or if external signaling is enabled on the receive system side. External signaling is enabled by selecting the RSIG pin function in registers PC(4:1) and setting XSP.CASEN = 1. Optionally the complete CAS multiframe can be transmitted on pin RSIG. The signaling data is clocked with the working clock of the receive highway (SCLKR) together with the receive synchronization pulse (SYPR). Data on RSIG is transmitted in the last 4 bits per time slot and is aligned to the data on RDO. The first 4 bits per time slot can be optionally fixed high or low (SIC2.SSF), except for time slot 0 and 16 (bit 1 to 4 are always "0000" in TS16). In time slot 0 the FAS/NFAS word is transmitted, in time slot 16 the CAS multiframe pattern "0000XYXX". Data on RSIG is only valid if the freeze signaling status is inactive. With FMR1.SAIS an all-ones data stream can be transmitted on RDO and RSIG. The signaling procedure is done as it is described in ITU-T G.704 and G.732. The main functions are: • Synchronization to a CAS multiframe • Detection of AIS and remote alarm in CAS multiframes • Separation of CAS service bits X1 to X3 Updating of the received signaling information is controlled by the freeze signaling status. The freeze signaling status is automatically activated if a loss-of-signal (FRS0.LOS = 1), or a loss of CAS multiframe alignment (FRS1.TSL16LFA = 1) or a receive slip occurs. The current freeze status is output on port FREEZE (RP(A:D)) and indicated by register SIS.SFS. Optionally automatic freeze signaling can be disabled by setting bit SIC3.DAF. After CAS resynchronization an interrupt is generated. Because at this time the signaling is still frozen, CAS data is not valid yet. Readout of CAS data has to be delayed until the next CAS multiframe is received. Data Sheet 76 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Because the CAS controller is working on the PCM highway side of the receive buffer, slips disturb the CAS data. 125 µs SYPR SCLKR T TS31 TS0 TS1 TS16 TS31 RDO 4 56 7 FAS/NFAS 0 12 34 5 67 0 12 34 5 67 01 2 34 5 67 RSIG ABCD FAS/NFAS ABCD 0 0 0 0XYXX A BCD T FAS NFAS ABCD 0000XYXX Figure 21 = Time slot offset (RC0, RC1) = Frame alignment signal = TS0 not containing FAS = Signaling bits for time slots 1...15 and 17...31 of CAS multiframe = CAS multiframe alignment signal in TS16 F0133 2.048 MHz Receive Signaling Highway (E1) 4.1.14.5 Channel Associated Signaling CAS (E1, µP access mode) The signaling information is carried in time slot 16 (TS16). Receive data is stored in registers RS(16:1) aligned to the CAS multiframe boundary. The signaling controller samples the bit stream either on the receive line side or if external signaling is enabled on the receive system side. The signaling procedure is done as it is described in ITU-T G.704 and G.732. The main functions are: • • • • Synchronization to a CAS multiframe Detection of AIS and remote alarm in CAS multiframes Separation of CAS service bits X1 to X3 Storing of received signaling data in registers RS(16:1) with last look capability Updating of the received signaling information is controlled by the freeze signaling status. The freeze signaling status is automatically activated if a loss-of-signal (FRS0.LOS = 1), or a loss of CAS multiframe alignment (FRS1.TSL16LFA = 1) or a receive slip occurs. The current freeze status is output on port FREEZE (RP(A:D)) and indicated by register SIS.SFS. Optionally automatic freeze signaling can be disabled by setting bit SIC3.DAF. If SIS.SFS is active, updating of the registers RS(16:1) is disabled. To relieve the µP load from always reading the complete RS(16:1) buffer every 2 ms the FALC56 notifies the µP through interrupt ISR0.CASC only when signaling changes from Data Sheet 77 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 one multiframe to the next. Additionally the FALC56 generates a receive signaling data change pointer (RSP1/2) which directly points to the updated RS(16:1) register. Because the CAS controller is working on the PCM highway side of the receive buffer, slips disturb the CAS data. Data Sheet 78 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.2 Framer Operating Modes (E1) 4.2.1 General Bit: FMR1.PMOD = 0 PCM line bit rate Single frame length Framing frequency HDLC controller Organization : : : : : 2.048 Mbit/s 256 bit, No. 1…256 8 kHz nx64 kbit/s, n = 1 to 32 or n×4 kbit/s, n = 1 to 5 32 time slots, No. 0…31 with 8 bits each, No. 1…8 The operating mode of the FALC56 is selected by programming the carrier data rate and characteristics, line code, multiframe structure, and signaling scheme. The FALC56 implements all of the standard framing structures for E1 or PCM 30 (CEPT, 2.048 Mbit/s) carriers. The internal HDLC or CAS controller supports all signaling procedures including signaling frame synchronization/synthesis and signaling alarm detection in all framing formats. The time slot assignment from the PCM line to the system highway and vice versa is performed without any changes of numbering (TS0 ↔ TS0, …, TS31 ↔ TS31). Summary of E1 Framing Modes • • • • • • Doubleframe format according to ITU-T G. 704 Multiframe format according to ITU-T G. 704 CRC4 processing according to ITU-T G. 706 Multiframe format with CRC4 to non CRC4 interworking according to ITU-T G. 706 Multiframe format with modified CRC4 to non CRC4 interworking Multiframe format with CRC4 performance monitoring After reset, the FALC56 is switched into doubleframe format automatically. Switching between the framing formats is done by programming bits FMR2.RFS1/0 and FMR3.EXTIW for the receiver and FMR1.XFS for the transmitter. Data Sheet 79 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.2.2 Doubleframe Format (E1) The framing structure is defined by the contents of time slot 0 (refer to Table 16). Table 16 Allocation of Bits 1 to 8 of Time Slot 0 (E1) Bit AlternateNumber Frames Frame Containing the Frame Alignment Signal 1 2 3 4 5 6 7 8 Si 0 0 1 1 0 1 1 Note 1) Frame Alignment Signal Sa5 Sa6 Sa7 Sa8 Frame not Containing the Frame Alignment Signal Si or Note 1) Service Word 1 A Sa4 Note 2) Note 3) Note 4) 1) Si-bits: reserved for international use. If not used, these bits should be fixed to "1". Access to received information trough bits RSW.RSI and RSP.RSIF. Transmission is enabled by bits XSW.XSIS and XSP.XSIF. 2) Fixed to "1". Used for synchronization. 3) Remote alarm indication: In undisturbed operation "0"; in alarm condition "1". 4) Sa-bits: Reserved for national use. If not used, they should be fixed at "1". Access to received information trough bits RSW.RY0…4. Transmission is enabled by bits XSW.XY0…4. HDLC signaling in bits Sa4 to 8 is selectable. As a special extension for double frame format, the Sa-bit registers RSA4 to 8/XSA4 to 8 can be used optionally. 4.2.2.1 Transmit Transparent Modes In transmit direction, contents of time slot 0 frame alignment signal of the outgoing PCM frame are normally generated by the FALC56. However, transparency for the complete time slot 0 can be achieved by selecting the transparent mode XSP.TT0. With the Transparent Service Word Mask register TSWM the Si-bits, A-bit and the Sa-bits can be selectively switched through transparently. Data Sheet 80 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Table 17 Transmit Transparent Mode (Doubleframe E1) Transmit Transparent Source for Enabled by – XSP.TT0 TSWM.TSIF TSWM.TSIS TSWM.TRA TSWM.TSA(8:4) Framing (int. gen.) via pin XDI1) (int. gen.) (int. gen.) (int. gen.) (int. gen.) A-Bit 2) XSW.XRA via pin XDI XSW.XRA XSW.XRA via pin XDI XSW.XRA Sa-Bits Si-Bits XSW.XY0…4 XSW.XSIS, XSP.XSIF via pin XDI via pin XDI via pin XDI XSW.XSIS, XSP.XSIF XSW.XSIS, XSP.XSIF 3) via pin XDI XSW.XY0…4 XSW.XY0…4 XSW.XY0…4 via pin XDI 1) pin XDI or XSIG or XFIFO buffer (signaling controller) 2) Additionally, automatic transmission of the A-bit is selectable. 3) As a special extension for double frame format, the Sa-bit register can be used optionally. 4.2.2.2 Synchronization Procedure Synchronization status is reported by bit FRS0.LFA. Framing errors are counted by the Framing Error Counter (FEC). Asynchronous state is reached after detecting 3 or 4 consecutive incorrect FAS words or 3 or 4 consecutive incorrect service words (bit 2 = 0 in time slot 0 of every other frame not containing the frame alignment word), the selection is done by bit RC0.ASY4. Additionally, the service word condition can be disabled. When the framer lost its synchronization an interrupt status bit ISR2.LFA is generated. In asynchronous state, counting of framing errors and detection of remote alarm is stopped. AIS is automatically sent to the backplane interface (can be disabled by bit FMR2.DAIS). Further on the updating of the registers RSW, RSP, RSA(8:4), RSA6S and RS(16:1) is halted (remote alarm indication, Sa/Si-Bit access). The resynchronization procedure starts automatically after reaching the asynchronous state. Additionally, it can be invoked user controlled by bit FMR0.FRS (force resynchronization, the FAS word detection is interrupted until the framer is in the asynchronous state. After that, resynchronization starts automatically). Synchronous state is established after detecting: • a correct FAS word in frame n, • the presence of the correct service word (bit 2 = 1) in frame n + 1, • a correct FAS word in frame n + 2. If the service word in frame n + 1 or the FAS word in frame n + 2 or both are not found searching for the next FAS word starts in frame n + 2 just after the previous frame alignment signal. Data Sheet 81 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Reaching the synchronous state causes a frame alignment recovery interrupt status ISR2.FAR if enabled. Undisturbed operation starts with the beginning of the next doubleframe. 4.2.2.3 A-Bit Access If the FALC56 detects a remote alarm indication in the received data stream the interrupt status bit ISR2.RA is set. With setting of bit XSW.XRA a remote alarm (RAI) is sent to the far end. By setting FMR2.AXRA the FALC56 automatically transmit the remote alarm bit = 1 in the outgoing data stream if the receiver detects a loss of frame alignment FRS0.LFA = 1. If the receiver is in synchronous state FRS0.LFA = 0 the remote alarm bit is reset. Note: The A-bit can be processed by the system interface. Setting bit TSWM.TRA enables transparency for the A-bit in transmit direction (refer to Table 16). 4.2.2.4 Sa-Bit Access As an extension for access to the Sa-bits through registers RSA(8:4)/XSA(8:4) an option is implemented to allow the usage of internal Sa-bit registers RSA(8:4)/XSA(8:4) in doubleframe format. This function is enabled by setting FMR1.ENSA = 1 for the transmitter and FMR1.RFS(1:0) = 01 for the receiver. In this case the FALC56 internally works with a 16frame structure but no CRC multiframe alignment/generation is performed. Data Sheet 82 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.2.3 CRC-Multiframe (E1) The multiframe structure shown in Table 18 is enabled by setting bit: FMR2.RFS1/0 for the receiver and FMR1.XFS for the transmitter. Multiframe Frame alignment Multiframe alignment CRC bits CRC block size CRC procedure Table 18 : : : : : : 2 submultiframes = 2 × 8 frames refer to section Doubleframe Format bit 1 of frames 1, 3, 5, 7, 9, 11 with the pattern "001011" bit 1 of frames 0, 2, 4, 6, 8, 10, 12, 14 2048 bit (length of a submultiframe) CRC4, according to ITU-T G.704 and G.706 CRC-Multiframe Structure (E1) SubMultiframe Multiframe I II Frame Number Bits 1 to 8 of the Frame 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 C1 0 C2 0 C3 1 C4 0 0 1 0 1 0 1 0 1 0 A 0 A 0 A 0 A 1 Sa4 1 Sa4 1 Sa4 1 Sa4 1 Sa5 1 Sa5 1 Sa5 1 Sa5 0 Sa61 0 Sa62 0 Sa63 0 Sa64 1 Sa7 1 Sa7 1 Sa7 1 Sa7 1 Sa8 1 Sa8 1 Sa8 1 Sa8 8 9 10 11 12 13 14 15 C1 1 C2 1 C3 E* C4 E* 0 1 0 1 0 1 0 1 0 A 0 A 0 A 0 A 1 Sa4 1 Sa4 1 Sa4 1 Sa4 1 Sa5 1 Sa5 1 Sa5 1 Sa5 0 Sa61 0 Sa62 0 Sa63 0 Sa64 1 Sa7 1 Sa7 1 Sa7 1 Sa7 1 Sa8 1 Sa8 1 Sa8 1 Sa8 E: Spare bits for international use. Access to received information through bits RSP.RS13 and RSP.RS15. Transmission is enabled by bits XSP.XS13 and XSP.XS15. Additionally, automatic transmission for submultiframe error indication is selectable. Sa: Spare bits for national use. Additionally, Sa-bit access through registers RSA4…8 and XSA4…8 is provided. HDLC-signaling in bits Sa4 to Sa8 is selectable. C1 … C4: Cyclic redundancy check bits. A: Remote alarm indication. Additionally, automatic transmission of the A-bit is selectable. Data Sheet 83 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 For transmit direction, contents of time slot 0 are additionally determined by the selected transparent mode. Table 19 Transmit Transparent Mode (CRC Multiframe E1) Transmit Transparent Source for enabled by Framing + CRC A-Bit Sa-Bits E-Bits – XSP.TT0 TSWM.TSIF TSWM.TSIS TSWM.TRA TSWM.TSA(8:4) (int. gen.) via pin XDI1) via pin XDI via pin XDI (int. gen.) (int. gen.) XSW.XRA2) via pin XDI XSW.XRA1) XSW.XRA1) via pin XDI XSW.XRA1) XSW.XY0 … 43) via pin XDI XSW.XY0 … 42) XSW.XY0 … 42) XSW.XY0 … 42) via pin XDI XSP.XS13/XS154) via pin XDI (int. generated) via pin XDI XSP.XS13/XS153) XSP.XS13/XS153) 1) pin XDI or XSIG or XFIFO buffer (signaling controller) 2) Automatic transmission of the A-bit is selectable 3) The Sa-bit register XSA(8:4) can be used optionally 4) Additionally, automatic transmission of submultiframe error indication is selectable The CRC procedure is automatically invoked when the multiframe structure is enabled. CRC errors in the received data stream are counted by the 16-bit CRC Error Counter CEC (one error per submultiframe, maximum). Additionally a CRC4 error interrupt status ISR0.CRC4 is generated if enabled by IMR0.CRC4. All CRC bits of one outgoing submultiframe are automatically inverted in case a CRC error is flagged for the previous received submultiframe. This function is enabled by bit RC0.CRCI. Setting of bit RC0.XCRCI inverts the CRC bits before transmission to the distant end. The function of RC0.XCRCI and RC0.CRCI are logically ored. 4.2.3.1 Synchronization Procedure Multiframe alignment is assumed to have been lost if doubleframe alignment has been lost (flagged on status bit FRS0.LFA). The rising edge of this bit causes an interrupt. The multiframe resynchronization procedure starts when Doubleframe alignment has been regained which is indicated by an interrupt status bit ISR2.FAR. For Doubleframe synchronization refer to section Doubleframe Format. It is also be invoked by the user by setting • bit FMR0.FRS for complete doubleframe and multiframe resynchronization • bit FMR1.MFCS for multiframe resynchronization only. The CRC checking mechanism is enabled after the first correct multiframe pattern has been found. However, CRC errors are not counted in asynchronous state. Data Sheet 84 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 In doubleframe asynchronous state, counting of framing errors, CRC4 bit errors and detection of remote alarm is stopped. AIS is automatically sent to the backplane interface (can be disabled by bit FMR2.DAIS). Further on the updating of the registers RSW, RSP, RSA(8:4), RSA6S and RS(16:1) is halted (remote alarm indication, Sa/Si-bit access). The multiframe synchronous state is established after detecting two correct multiframe alignment signals at an interval of n × 2 ms (n = 1, 2, 3 …). The loss of multiframe alignment flag FRS0.LMFA is reset. Additionally an interrupt status multiframe alignment recovery bit ISR2.MFAR is generated with the falling edge of bit FRS0.LMFA. 4.2.3.2 Automatic Force Resynchronization (E1) In addition, a search for Doubleframe alignment is automatically initiated if two multiframe pattern with a distance of n × 2 ms have not been found within a time interval of 8 ms after doubleframe alignment has been regained (bit FMR1.AFR). A new search for frame alignment is started just after the previous frame alignment signal. 4.2.3.3 Floating Multiframe Alignment Window (E1) After reaching doubleframe synchronization a 8 ms timer is started. If a multiframe alignment signal is found during the 8 ms time interval the internal timer is reset to remaining 6 ms in order to find the next multiframe signal within this time. If the multiframe signal is not found for a second time, the interrupt status bit ISR0.T8MS is set. This interrupt usually occurs every 8 ms until multiframe synchronization is achieved. 4.2.3.4 CRC4 Performance Monitoring (E1) In the synchronous state checking of multiframe pattern is disabled. However, with bit FMR2.ALMF an automatic multiframe resynchronization mode can be activated. If 915 out of 1000 errored CRC submultiframes are found then a false frame alignment is assumed and a search for doubleframe and multiframe pattern is initiated. The new search for frame alignment is started just after the previous basic frame alignment signal. The internal CRC4 resynchronization counter is reset when the multiframe synchronization has been regained. 4.2.3.5 Modified CRC4 Multiframe Alignment Algorithm (E1) The modified CRC4 multiframe alignment algorithm allows an automatic interworking between framers with and without a CRC4 capability. The interworking is realized as it is described in ITU-T G.706 Appendix B. If doubleframe synchronization is consistently present but CRC4 multiframe alignment is not achieved within 400 ms it is assumed that the distant end is initialized to doubleframe format. The CRC4/non-CRC4 interworking is enabled by FMR2.RFS1/0 = 11 and is activated only if the receiver has lost its synchronization. If doubleframe alignment (basic Data Sheet 85 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 frame alignment) is established, a 400 ms timer and searching for multiframe alignment are started. A research for basic frame alignment is initiated if the CRC4 multiframe synchronization cannot be achieved within 8 ms and is started just after the previous frame alignment signal. The research of the basic frame alignment is done in parallel and is independent of the synchronization procedure of the primary basic frame alignment signal. During the parallel search all receiver functions are based on the primary frame alignment signal, like framing errors, Sa-, Si-, A-bits, …). All subsequent multiframe searches are associated with each basic framing sequence found during the parallel search. If the CRC4 multiframe alignment sequence was not found within the time interval of 400 ms, the receiver is switched into a non-CRC4 mode indicated by setting the bit FRS0.NMF (No Multiframing Found) and ISR2.T400MS. In this mode checking of CRC bits is disabled and the received E-bits are forced to low. The transmitter framing format is not changed. Even if multiple basic FAS resynchronizations have been established during the parallel search, the receiver is maintained to the initially determined primary frame alignment signal location. However, if the CRC4-multiframe alignment can be achieved within the 400 ms time interval assuming a CRC4-to-CRC4 interworking, then the basic frame alignment sequence associated to the CRC4 multiframe alignment signal is chosen. If necessary, the primary frame alignment signal location is adjusted according to the multiframe alignment signal. The CRC4 performance monitoring is started if enabled by FMR2.ALMF and the received E-bits are processed in accordance to ITU-T G.704. Switching into the doubleframe format (non-CRC4) mode after 400 ms can be disabled by setting of FMR3.EXTIW. In this mode the FALC56 continues to search for multiframing. In the interworking mode setting of bit FMR1.AFR is not allowed. 4.2.3.6 A-Bit Access (E1) If the FALC56 detects a remote alarm indication (bit 2 in TS0 not containing the FAS word) in the received data stream the interrupt status bit ISR2.RA is set. With the deactivation of the remote alarm the interrupt status bit ISR2.RAR is generated. By setting FMR2.AXRA the FALC56 automatically transmits the remote alarm bit = 1 in the outgoing data stream if the receiver detects a loss of frame alignment (FRS0.LFA = 1). If the receiver is in synchronous state (FRS0.LFA = 0), the remote alarm bit is reset in the outgoing data stream. Additionally, if bit FMR3.EXTIW is set and the multiframe synchronous state cannot be achieved within 400 ms after finding the primary basic framing, the A-bit is transmitted active high to the remote end until the multiframing is found. Note: The A-bit can be processed by the system interface. Setting bit TSWM.TRA enables transparency for the A-bit in transmit direction (refer to Table 18). Data Sheet 86 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.2.3.7 Sa-Bit Access (E1) Due to signaling procedures using the five Sa-bits (Sa4…Sa8) of every other frame of the CRC multiframe structure, three possibilities of access by the microprocessor are implemented. • The standard procedure allows reading/writing the Sa-bit registers RSW, XSW without further support. The Sa-bit information is updated every other frame. • The advanced procedure, enabled by bit FMR1.ENSA, allows reading/writing the Sabit registers RSA4…8, XSA4…8. A transmit or receive multiframe begin interrupt (ISR0.RMB or ISR1.XMB) is provided. Registers RSA(8:4) contains the service word information of the previously received CRC-multiframe or 8 doubleframes (bit slots 4 to 8 of every service word). These registers are updated with every multiframe begin interrupt ISR0.RMB. With the transmit multiframe begin an interrupt ISR1.XMB is generated and the contents of the registers XSA(8:4) is copied into shadow registers. The contents is subsequently sent out in the service words of the next outgoing CRC multiframe (or every doubleframe) if none of the time slot 0 transparent modes is enabled. The transmit multiframe begin interrupt XMB request that these registers issue should be serviced. If requests for new information are ignored, the current contents is repeated. • The extended access through the receive and transmit FIFOs of the signaling controller. In this mode it is possible to transmit/receive a HDLC frame or a transparent bit stream in any combination of the Sa-bits. Enabling is done by setting of bit CCR1.EITS and the corresponding bits XC0.SA8E to SA4E/TSWM.TSA8 to TSA4 and resetting of registers TTR(4:1), RTR(4:1) and FMR1.ENSA. The access to and from the FIFOs is supported by ISR0.RME, RPF and ISR1.XPR, ALS. Sa6-Bit Detection according to ETS 300233 Four consecutive received Sa6-bits are checked for the combinations defined by ETS 300233. The FALC56 detects the following fixed Sa6-bit combinations: SA61, SA62, SA63, SA64 = 1000, 1010, 1100, 1110, 1111. All other possible 4-bit combinations are grouped to status “X”. A valid Sa6-bit combination must occur three times in a row. The corresponding status bit in register RSA6S is set. Register RSA6S is of type “clear on read”. Any status change of the Sa6-bit combinations causes an interrupt (ISR0.SA6SC). During the basic frame asynchronous state update of register RSA6S and interrupt status ISR0.SA6SC is disabled. In multiframe format the detection of the Sa6-bit combinations can be done either synchronously or asynchronously to the submultiframe (FMR3.SA6SY). In synchronous detection mode updating of register RSA6S is done in the multiframe synchronous state (FRS0.LMFA = 0). In asynchronous detection mode updating is independent of the multiframe synchronous state. Data Sheet 87 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Sa6-Bit Error Indication Counters The Sa6-bit error indication counter CRC2L/H (16 bits) counts the received Sa6-bit sequence 0001 or 0011 in every CRC submultiframe. In the primary rate access digital section this counter option gives information about CRC errors reported from the TE by the Sa6 bit. Incrementing is only possible in the multiframe synchronous state. The Sa6bit error indication counter CRC3L/H (16 bits) counts the received Sa6-bit sequence 0010 or 0011 in every CRC submultiframe. In the primary rate access digital section this counter option gives information about CRC errors detected at T-reference point and reporting them by the Sa6-bit. Incrementing is only possible in the multiframe synchronous state. 4.2.3.8 E-Bit Access (E1) Due to signaling requirements, the E-bits of frame 13 and frame 15 of the CRC multiframe can be used to indicate received errored submultiframes: Submultiframe I statusE-bit located in frame 13 Submultiframe II statusE-bit located in frame 15 no CRC error: E = 1; CRC error:E = 0 Standard Procedure After reading the submultiframe error indication RSP.SI1 and RSP.SI2, the microprocessor has to update the contents of register XSP (XS13, XS15). Access to these registers has to be synchronized on transmit or receive multiframe begin interrupts (ISR0.RMB or ISR1.XMB). Automatic Mode In the multiframe synchronous state the E-bits are processed according to ITU-T G.704 independently of bit XSP.EBP (E-bit polarity selection). By setting bit XSP.AXS status information of received submultiframes is automatically inserted in the E-bit position of the outgoing CRC multiframe without any further interventions of the microprocessor. In the doubleframe and multiframe asynchronous state the E-bits are set or cleared, depending on the setting of bit XSP.EBP. Submultiframe Error Indication Counter The EBC (E-Bit) counter EBCL/H (16 bits) counts zeros in the E-bit position of frame 13 and 15 of every received CRC multiframe. This counter option gives information about the outgoing transmit PCM line if the E-bits are used by the remote end for submultiframe error indication. Incrementing is only possible in the multiframe synchronous state. Data Sheet 88 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Note: E-bits can be processed by the system interface. Setting bit TSWM.TSIS enables transparency for E-bits in transmit direction (refer to Table 18). OUT of Primary BFA: Inhibit Incoming CRC-4 Performance Monitoring Reset all Timers Set FRS0.LFA/LMFA/NMF = 110 No Primary BFA Search ? Yes IN Primary BFA: Start 400 ms Timer Enable Primary BFA Loss Checking Process Reset Internal Frame Alignment Status (FRS0.LFA = 0) CRC-4 MFA Search Start 8 ms Timer Yes No Parallel BFA Search Good ? No Yes Can CRC-4 MFA be found in 8 ms ? No 400 ms Timer Elapsed ? Yes Assume CRC-4 to CRC-4 Interworking: Confirm Primary BFA Associated with CRC-4 MFA Adjust Primary BFA if Necessary Reset Internal Multiframe Alignment Status (FRS0.LMFA = 0) Assume CRC-4 to non CRC-4 Interworking: Confirm Primary BFA Set Internal 400 ms Timer Expiration Status Bit (FRS0.NMF = 1) Start CRC-4 Performance Monitoring Yes CRC-4 Error Count <_ 915 or LFA ? No Continue CRC-4 Performance Monitoring ITD10310 Figure 22 CRC4 Multiframe Alignment Recovery Algorithms (E1) Data Sheet 89 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.3 Additional Receive Framer Functions (E1) 4.3.1 Error Performance Monitoring and Alarm Handling Alarm Indication Signal: Detection and recovery is flagged by bit FRS0.AIS and ISR2.AIS. Transmission is enabled by bit FMR1.XAIS. Loss-Of-Signal: Detection and recovery is flagged by bit FRS0.LOS and ISR2.LOS. Remote Alarm Indication: Detection and release is flagged by bit FRS0.RRA, RSW.RRA and ISR2.RA/RAR. Transmission is enabled by bit XSW.XRA. AIS in time slot 16: Detection and release is flagged by bit FRS1.TS16AIS and ISR3.AIS16. Transmission is enabled by writing all ones in registers XS(16:1). LOS in time slot 16: Detection and release is flagged by bit FRS1.TS16LOS. Transmission is enabled by writing all zeros in registers XS(16:1). Remote Alarm in time slot 16: Detection and release is flagged by bit FRS1.TS16RA and ISR3.RA16. Transmission is enabled by bit XS1.2. Transmit Line Shorted: Detection and release is flagged by bit FRS1.XLS and ISR1.XLSC. Transmit Ones-Density: Detection and release is flagged by bit FRS1.XLO and ISR1.XLSC. Table 20 Summary of Alarm Detection and Release (E1) Alarm Detection Condition Clear Condition Loss-Of-Signal (LOS) no transitions (logical zeros) in a programmable time interval of 16 to 4096 consecutive pulse periods. Programmable receive input signal threshold programmable number of ones (1 to 256) in a programmable time interval of 16 to 4096 consecutive pulse periods. A one is a signal with a level above the programmed threshold. Alarm Indication Signal (AIS) FMR0.ALM = 0: less than 3 zeros in 250 µs and loss of frame alignment declared FMR0.ALM = 0: more than 2 zeros in 250 µs FMR0.ALM = 1: less than 3 zeros in each of two consecutive 250-µs periods Remote Alarm (RRA) Data Sheet bit 3 = 1 in time slot 0 not containing the FAS word 90 FMR0.ALM = 1: more than 2 zeros in each of two 500-µs periods set conditions no longer detected. 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Table 20 Summary of Alarm Detection and Release (E1) (cont’d) Alarm Detection Condition Remote Alarm in Y-bit = 1 received in CAS time slot 16 (TS16RA) multiframe alignment word Clear Condition Y-bit = 0 received in CAS multiframe alignment word Loss-of-Signal in time slot 16 (TS16LOS) all zeros for at least 16 receiving a one in consecutively received time time slot 16 slots 16 Alarm Indication Signal in time slot 16 (TS16AIS) time slot 16 containing less time slot 16 containing more than than 4 zeros in each of two 3 zeros in one CAS multiframe consecutive CAS multiframes periods Transmit Line Short (XLS) more than 3 pulse periods with highly increased transmit line current on XL1/2 Transmit OnesDensity (XLO) 32 consecutive zeros in the Cleared with each transmitted transmit data stream on pulse XL1/2 4.3.2 transmit line current limiter inactive Auto Modes • Automatic remote alarm access If the receiver has lost its synchronization a remote alarm can be sent automatically, if enabled by bit FMR2.AXRA to the distant end. The remote alarm bit is set automatically in the outgoing data stream, if the receiver is in asynchronous state (FRS0.LFA bit is set). In synchronous state the remote alarm bit is removed. • Automatic E-bit access By setting bit XSP.AXS status information of received submultiframes is automatically inserted at the E-bit position of the outgoing CRC Multiframe without any further interventions of the microprocessor. • Automatic AIS to system interface In asynchronous state the synchronizer enforces an AIS to the receive system interface automatically. However, received data can be switched through transparently, if bit FMR2.DAIS is set. • Automatic clock source switching In slave mode (LIM0.MAS = 0) the DCO-R synchronizes to the recovered route clock. In case of loss-of-signal (LOS) the DCO-R switches to Master mode automatically. If bit CMR1.DCS is set, automatic switching from RCLK to SYNC is disabled. • Automatic freeze signaling: Updating of the received signaling information is controlled by the freeze signaling status. The freeze signaling status is automatically activated if a loss-of-signal or a Data Sheet 91 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 loss of CAS multiframe alignment or a receive slip occurs. The internal signaling buffer RS(16:1) is frozen. Optionally automatic freeze signaling is disabled by setting bit SIC3.DAF. 4.3.3 Error Counter The FALC56 offers six error counters where each of them has a length of 16 bit. They record code violations, framing bit errors, CRC4-bit errors and CRC4 error events which are flagged in the different Sa6-bit combinations or the number of received multiframes in asynchronous state or the change of frame alignment (COFA). Counting of the multiframes in the asynchronous state and the COFA parameter is done in a 6/2 bit counter and is shared with CEC3L/H. Each of the error counters is buffered. Buffer updating is done in two modes: • One-second accumulation • On demand by handshake with writing to the DEC register In the one-second mode an internal/external one-second timer updates these buffers and resets the counter to accumulate the error events in the next one-second period. The error counter cannot overflow. Error events occurring during an error counter reset are not lost. 4.3.4 Errored Second The FALC56 supports the error performance monitoring by detecting the following alarms or error events in the received data: framing errors, CRC errors, code violations, loss of frame alignment, loss-of-signal, alarm indication signal, E-bit error, receive and transmit slips. With a programmable interrupt mask register ESM all these alarms or error events can generate an errored second interrupt (ISR3.ES) if enabled. 4.3.5 One-Second Timer Additionally, a one-second timer interrupt can be generated internally to indicate that the enabled alarm status bits or the error counters have to be checked. The one-second timer signal is output on port SEC/FSC (GPC1.CSFP1/0). Optionally synchronization to an external second timer is possible which has to be provided on pin SEC/FSC. Selecting the external second timer is done with GCR.SES. Refer also to register GPC1 for input/output selection. 4.3.6 In-Band Loop Generation and Detection The FALC56 generates and detects a framed or unframed in-band loop-up (activate) and loop-down (deactivate) pattern with bit error rates up to 10-2. Framed or unframed inband loop code is selected by LCR1.FLLB. Replacing transmit data with the in-band loop codes is done by programming FMR3.XLD/XLU. Data Sheet 92 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 The FALC56 also offers the ability to generate and detect a flexible in-band loop-up and loop-down pattern (LCR1.LLBP = 1). The loop-up and loop-down pattern is individually programmable from 2 to 8 bits in length (LCR1.LAC1/0 and LCR1.LDC1/0). Programming of loop codes is done in registers LCR2 and LCR3. Status and interrupt status bits inform the user whether loop-up or loop-down code has been detected. 4.3.7 Time Slot 0 Transparent Mode The transparent modes are useful for loop-backs or for routing data unchanged through the FALC56. In receive direction, transparency for ternary or dual-/single-rail unipolar data is always achieved if the receiver is in the synchronous state. In asynchronous state data is transparently switched through if bit FMR2.DAIS is set. However, correct time slot assignment cannot be guaranteed due to missing frame alignment between line and system side. Setting of bit LOOP.RTM disconnects control of the internal elastic store from the receiver. The elastic buffer is now in a “free running” mode without any possibility to update the time slot assignment to a new frame position in case of resynchronization of the receiver. Together with FMR2.DAIS this function can be used to realize undisturbed transparent reception. Transparency in transmit direction can be achieved by activating the time slot 0 transparent mode (bit XSP.TT0 or TSWM.(7:0)). If XSP.TT0 = 1 all internal information of the FALC56 (framing, CRC, Sa/Si-bit signaling, remote alarm) is ignored. With register TSWM the Si-bits, A-bit or the Sa-bits can be enabled selectively to send data transparently from port XDI to the far end. For complete transparency the internal signaling controller, idle code generation and AIS alarm generation, single channel and payload loop-back have to be disabled. Data Sheet 93 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.4 Transmit Path in E1 Mode 4.4.1 Transmitter (E1) The serial bit stream is processed by the transmitter which has the following functions: • • • • • • • Frame/multiframe synthesis of one of the two selectable framing formats Insertion of service and data link information AIS generation (Alarm indication signal) Remote alarm generation CRC generation and insertion of CRC bits CRC bits inversion in case of a previously received CRC error Idle code generation per DS0 The frame/multiframe boundaries of the transmitter can be externally synchronized by using the SYPX/XMFS pin. Any change of the transmit time slot assignment subsequently produces a change in the framing bit positions on the line side. This feature is required if signaling and service bits are routed through the switching network and are inserted in transmit direction by the system interface. In loop-timed configuration (LIM2.ELT = 1) disconnecting the control of the transmit system highway from the transmitter is done by setting XSW.XTM. The transmitter is now in a free running mode without any possibility to update the multiframe position in case of changing the transmit time slot assignment. The framing bits are generated independently of the transmit system interface. For proper operation the transmit elastic buffer size should be programmed to 2 frames. The contents of selectable time slots can be overwritten by the pattern defined by register IDLE. The selection of “idle channels” is done by programming the four-byte registers ICB1…ICB4. Data Sheet 94 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.4.2 Transmit Line Interface (E1) The analog transmitter transforms the unipolar bit stream to ternary (alternate bipolar) return to zero signals of the appropriate programmable shape. The unipolar data is provided by the digital transmitter. R1 XL1 Line t1 t2 FALC R R1 XL2 ITS10968 Figure 23 Transmitter Configuration (E1) Table 21 Recommended Transmitter Configuration Values (E1) Characteristic Impedance [Ω] Parameter R1 (± 1%) [Ω] t2 : t1 1) 120 75 7.51) 7.51) 1 : 2.4 1 : 2.4 This value refers to an ideal transformer without any parasitics. Any transformer resistance or other parasitic resistances have to be taken into account when calculating the final value of the output serial resistors. Similar to the receive line interface three different data types are supported: • Ternary Signal Single-rail data is converted into a ternary signal which is output on pins XL1 and XL2. The HDB3 and AMI line code is employed. Selected by FMR0.XC1/0 and LIM1.DRS = 0. • Dual-rail data PCM(+), PCM(–) at multifunction ports XDOP/XDON with 50% or 100% duty cycle and with programmable polarity. Line coding is done in the same way as in ternary interface mode. Selected by FMR0.XC1/0 and LIM1.DRS = 1. • Unipolar data on port XOID is transmitted either in NRZ (Non Return to Zero) with 100% duty cycle or in CMI (Code Mark Inversion or known as 1T2B) Code with or without (FMR3.CMI) preprocessed HDB3 coding to a fiber-optical interface. Clocking off data is done with the rising edge of the transmit clock XCLK (2048 kHz) and with a programmable polarity. Selection is done by FMR0.XC1 = 0 and LIM1.DRS = 1. Data Sheet 95 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.4.3 Transmit Jitter Attenuator (E1) The transmit jitter attenuator DCO-X circuitry generates a "jitter-free" transmit clock and meets the following requirements: ITU-T I.431, G. 703, G. 736 to 739, G.823 and ETSI TBR12/13. The DCO-X circuitry works internally with the same high frequency clock as the receive jitter attenuator. It synchronizes either to the working clock of the transmit backplane interface or the clock provided on pin TCLK or the receive clock RCLK (remote loop/loop-timed). The DCO-X attenuates the incoming clock jitter starting at 2 Hz with 20 dB per decade fall-off. With the jitter attenuated clock, which is directly depending on the phase difference of the incoming clock and the jitter attenuated clock, data is read from the transmit elastic buffer (2 frames) or from the JATT buffer (2 frames, remote loop). Wander with a jitter frequency below 2 Hz is passed transparently. The DCO-X accepts gapped clocks which are used in ATM or SDH/SONET applications. The jitter attenuated clock is output on pin XCLK or optionally on pin CLK2. In case of missing clock on pin SCLKX the DCO-X centers automatically, if selected by bit CMR2.DCOXC = 1. The transmit jitter attenuator can be disabled. In that case data is read from the transmit elastic buffer with the clock sourced on pin TCLK (2.048 or 8.192 MHz). Synchronization between SCLKX and TCLK has to be done externally. In the loop-timed clock configuration (LIM2.ELT) the DCO-X circuitry generates a transmit clock which is frequency synchronized on RCLK. In this configuration the transmit elastic buffer has to be enabled. Data Sheet 96 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 XL1/ XDOP/ XOID XL2/ XDON DR D DR Framer A Transmit Elastic Store XDI Pulse Shaper XCLK TCLK (E1: 8MHz) (T1: 6MHz) SCLKR ÷4 E1: 8MHz T1: 6MHz DCO-X Transmit Jitter Attenuator MCLK Figure 24 Clocking Unit Internal Clock of Receive System Interface SCLKX TCLK RCLK ITS10305 Transmit Clock System (E1) Note: DR = Dual-Rail interface DCO-X Digital Controlled Oscillator transmit 4.4.4 Transmit Elastic Buffer (E1) The received bit stream from pin XDI is optionally stored in the transmit elastic buffer. The memory is organized as the receive elastic buffer. The functions are also equal to the receive side. Programming of the transmit buffer size is done by SIC1.XBS1/0: • XBS1/0 = 00: Bypass of the transmit elastic buffer • XBS1/0 = 01: one frame buffer or 256 bits Maximum of wander amplitude (peak-to-peak): 100 UI (1 UI = 488 ns) average delay after performing a slip: 128 bits • XBS1/0 = 10: two frame buffer or 512 bits Maximum of wander amplitude: 190 UI average delay after performing a slip: 1 frame or 256 bits • XBS1/0 = 11: short buffer or 92 bits: Maximum of wander amplitude: 18 us average delay after performing a slip: 46 bits The functions of the transmit buffer are: Data Sheet 97 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 • Clock adaption between system clock (SCLKX) and internally generated transmit route clock (XCLK). • Compensation of input wander and jitter. • Frame alignment between system frame and transmit route frame • Reporting and controlling of slips Writing of received data from XDI is controlled by SCLKX/R and SYPX/XMFS in combination with the programmed offset values for the transmit time slot/clock slot counters. Reading of stored data is controlled by the clock generated by DCO-X circuitry or the externally generated TCLK and the transmit framer. With the de-jittered clock data is read from the transmit elastic buffer and are forwarded to the transmitter. Reporting and controlling of slips is done according to the receive direction. Positive/negative slips are reported in interrupt status bits ISR4.XSP and ISR4.XSN. If the transmit buffer is bypassed data is directly transferred to the transmitter. The following table gives an overview of the transmit buffer operating modes. Table 22 Transmit Buffer Operating Modes (E1) SIC1.XBS(1:0) Buffer Size TS Offset programming Slip performance 00 bypass enabled no 11 short buffer enabled yes 01 1 frame enabled yes 10 2 frames enabled yes 4.4.5 Programmable Pulse Shaper (E1) The analog transmitter includes a programmable pulse shaper to satisfy the requirements of ITU-T I.431. The amplitude and shape of the transmit pulses are completely programmable by registers XPM(2:0). The transmitter requires an external step up transformer to drive the line. 4.4.6 Transmit Line Monitor (E1) The transmit line monitor compares the transmit line current on XL1 and XL2 with an onchip transmit line current limiter. The monitor detects faults on the primary side of the transformer indicated by a highly increased transmit line current (more than 120 mA for at least 3 consecutive pulses sourced by VDDX1)) and protects the device from damage by setting the transmit line driver XL1/2 into high-impedance state automatically (if enabled by XPM2.DAXLT = 0). The current limiter checks the actual current value of 1) shorts between XL1 or XL2 and VDDX are not detected Data Sheet 98 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 XL1/2 and if the transmit line current drops below the detection limit the high-impedance state is cleared. Two conditions are detected by the monitor: transmit line de-jitteredity (more than 31 consecutive zeros) indicated by FRS1.XLO and transmit line high current indicated by FRS1.XLS. In both cases a transmit line monitor status change interrupt is provided. Line Monitor TRI XL1 Pulse Shaper XL2 XDATA ITS10936 Figure 25 4.4.7 Transmit Line Monitor Configuration (E1) Transmit Signaling Controller (E1) Similar to the receive signaling controller the same signaling methods and the same time slot assignment is provided. The FALC56 performs the following signaling and data link methods. 4.4.7.1 HDLC or LAPD access The transmit signaling controller of the FALC56 performs the flag generation, CRC generation, zero-bit stuffing and programmable idle code generation. Buffering of transmit data is done in the 64 byte deep XFIFO. The signaling information is internally multiplexed with the data applied to port XDI or XSIG. In signaling controller transparent mode, fully transparent data transmission without HDLC framing is performed. Optionally the FALC56 supports the continuous transmission of the XFIFO contents. The FALC56 offers the flexibility to insert data during certain time slots. Any combinations of time slots can be programmed separately for the receive and transmit direction if using HDLC channel 1. HDLC channel 2 and 3 support one programmable time slot common for receive and transmit direction each. Data Sheet 99 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.4.7.2 Support of Signaling System #7 The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is described in ITU-Q.703. The following description assumes, that the reader is familiar with the SS7 protocol definition. SS7 support must be activated by setting the MODE register. Data stored in the transmit FIFO (XFIFO) is sent automatically. The SS7 protocol is supported by the following hardware features in transmit direction: • transmission of flags at the beginning of each Signaling Unit • bit stuffing (zero insertion) • calculation of the CRC16 checksum: The transmitter adds the checksum to each Signaling Unit. Each Signaling Unit written to the transmit FIFO (XFIFO, 2×32 bytes) is sent once or repeatedly including flags, CRC checksum and stuffed bits. After e.g. an MSU has been transmitted completely, the FALC56 optionally starts sending of FISUs containing the forward sequence number (FSN) and the backward sequence number (BSN) of the previously transmitted Signaling Unit. Setting bit CCR5.AFX causes Fill In Signaling Units (FISUs) to be sent continuously, if no HDLC or Signaling Unit (SU) is to be transmitted from XFIFO. During update of XFIFO, automatic transmission is interrupted and resumed after update is completed. The internally generated FISUs contain FSN and BSN of the last transmitted Signaling Unit written to XFIFO. Using CMDR.XREP = 1, the contents of XFIFO can be sent continuously. Clearing of CMDR.XRES/SRES stops the automatic repetition of transmission. This function is also available for HDLC frames, so no flag generation, CRC byte generation and bit stuffing is necessary. Example: After an MSU has been sent repetitively and XREP has been cleared, FISUs are sent automatically. 4.4.7.3 Sa-Bit Access (E1) The FALC56 supports the Sa-bit signaling of time slot 0 of every other frame as follows: • the access through register XSW • the access through registers XSA(8:4), capable of storing the information for a complete multiframe • the access through the 64 byte deep XFIFO of the signaling controller (HDLC channel 1 only) This Sa-bit access gives the opportunity to transparent a bit stream as well as HDLC frames where the signaling controller automatically processes the HDLC protocol. Any combination of Sa-bits which shall be inserted in the outgoing data stream can be selected by XC0.SA(8:4). Data Sheet 100 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.4.7.4 Channel Associated Signaling CAS (E1, serial mode) In external signaling mode (serial mode) the signaling data received on port XSIG is sampled with the working clock of the transmit system interface (SCLKX) in combination with the transmit synchronization pulse (SYPX). Data on XSIG is latched in the bit positions 5 to 8 per time slot, bits 1 to 4 are ignored. Time slots 0 and 16 are sampled completely (bit 1 to 8). The received CAS multiframe is inserted frame aligned into the data stream on XDI and must be valid during the last frame of a multiframe if CRC4/ multiframe mode is selected. The CAS multiframe is aligned to the CRC4-multiframe; other frames are ignored. Data sourced by the internal signaling controller (µP access mode) overwrites the external signaling data. If the FALC56 is configured for no signaling, the system interface data stream passes the FALC56 undisturbedly. Note: CAS data on XSIG is read in the last frame of a multiframe only and ignored in all other frames. 125 µs SYPX SCLKX T TS31 TS0 TS1 TS16 TS31 XDI 4 56 7 FAS/NFAS 0 12 34 5 67 0 12 34 5 67 01 2 34 5 67 XSIG ABCD FAS/NFAS A BCD 0 0 0 0XYXX A BCD T FAS NFAS ABCD 0000XYXX Figure 26 4.4.7.5 = Time slot offset (XC0, XC1) = Frame alignment signal, is taken from XSIG, not from XDI = TS0 not containing FAS = Signaling bits for time slots 1...15 and 17...31 of CAS multiframe = CAS multiframe alignment signal, has to be provided in TS16 F0132 2.048 MHz Transmit Signaling Highway (E1) Channel Associated Signaling CAS (E1, µP access mode) Transmit data stored in registers XS(16:1) is transmitted on a multiframe boundary in time slot 16. The signaling controller inserts the bit stream either on the transmit line side or, if external signaling is enabled, on the transmit system side using pin function XSIG. Data sourced by the internal signaling controller overwrites the external signaling data. If the FALC56 is configured for no signaling, the system interface data stream passes the FALC56 undisturbedly. Data Sheet 101 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.5 System Interface in E1 Mode The FALC56 offers a flexible feature for system designers where for transmit and receive direction different system clocks and system pulses are necessary. The interface to the receive system highway is realized by two data buses, one for the data RDO and one for the signaling data RSIG. The receive highway is clocked on pin SCLKR, while the interface to the transmit system highway is independently clocked on pin SCLKX. The frequency of these working clocks and the data rate of 2.048/4.096/8.192/16.384 Mbit/s for the receive and transmit system interface is programmable by SIC1.SSC1/0, and SIC1.SSD1, FMR1.SSD0. Selectable system clock and data rates and their valid combinations are shown in the table below Table 23 System Clocking and Data Rates (E1) System Data Rate Clock Rate 2.048 MHz Clock Rate 4.096 MHz Clock Rate 8.192 MHz Clock Rate 16.384 MHz 2.048 Mbit/s x x x x 4.096 Mbit/s -- x x x 8.192 Mbit/s -- -- x x 16.384 Mbit/s -- -- -- x x = valid, -- = invalid Generally the data or marker on the system interface are clocked off or latched on the rising or falling edge (SIC3.RESR/X) of the SCLKR/X clock. Some clocking rates allow transmission of time slots in different channel phases. Each channel phase which shall be active on ports RDO, XDI, RP(A:D) and XP(A:D) is programmable by SIC2.SICS(2:0), the remaining channel phases are cleared or ignored. The signals on pin SYPR together with the assigned time slot offset in register RC0 and RC1 define the beginning of a frame on the receive system highway.The signal on pin SYPX or XMFS together with the assigned time slot offset in register XC0 and XC1 define the beginning of a frame on the transmit system highway. Adjusting the frame begin (time slot 0, bit 0) relative to SYPR/X or XMFS is possible in the range of 0 to 125 µs. The minimum shift of varying the time slot 0 begin can be programmed between 1 bit and 1/8 bit depending of the system clocking and data rate, e.g. with a clocking/data rate of 2.048 MHz shifting is done bit by bit, while running the FALC56 with 16.384 MHz and 2.048 Mbit/s data rate it is done by 1/8 bit. A receive frame marker RFM can be activated during any bit position of the entire frame. Programming is done with registers RC1/0. The pin function RFM is selected by PC(4:1).RPC(2:0) = 001. The RFM selection disables the internal time slot assigner, no offset programming is performed. The receive frame marker is active high for one Data Sheet 102 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 2.048 MHz cycle and is clocked off with the rising or falling edge of the clock which is in/ output on port SCLKR (see SIC3.RESR/X). Compared to the receive path the inverse functions are performed for the transmit direction. The interface to the transmit system highway is realized by two data buses, one for the data XDI and one for the signaling data XSIG. The time slot assignment is equivalent to the receive direction. Latching of data is controlled by the system clock (SCLKX) and the synchronization pulse (SYPX/XMFS) in combination with the programmed offset values for the transmit time slot/clock slot counters XC1/0. The frequency of the working clock of 2.048/4.096/ 8.192/16.384 MHz for the transmit system interface is programmable by SIC1.SSC1/0. Refer also toTable 23. The received bit stream on ports XDI and XSIG can be multiplexed internally on a time slot basis, if enabled by SIC3.TTRF = 1. The data received on port XSIG can be sampled if the transmit signaling marker XSIGM is active high. Data on port XDI is sampled if XSIGM is low for the corresponding time slot. Programming the XSIGM marker is done with registers TTR(4:1). Data Sheet 103 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 SCLKR DCO-R RSIGM Receive Signaling Buffer RSIG RMFB Receive Elastic Buffer RFM RP(A...D) DLR FREEZE RFSP SYPR Receive Backplane DCO-R BYP Receive Data Receive Jitter Attenuator Receive Clock RDO DCO-R SCLKX XLT Transmit Signaling Buffer XSIG SYPX XP(A...D) XMFS Transmit Backplane Transmit Elastic Buffer TCLK XSIGM XMFB DLX XCLK Transmit Data Transmit Clock Figure 27 Data Sheet BYP PLB XDI Transmit Jitter Attenuator TCLK RCLK F0118 System Interface (E1) 104 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Multi Frame 1 Multi Frame 2 ~ ~ Receive System Interface (E1) ~ ~ 4.5.1 FRAME 1 FRAME 2 FRAME 3 RDO FRAME 15 FRAME 16 FRAME 1 FRAME 2 FRAME 15 ~~ ~~ ~~ RMFB SYPR SYPR Sample Edge Trigger Edge 1) SCLKR 8.192 MHz T Programmable via RC0/1 SCLKR 2.048 MHz TS0 RDO/RSIG Bit 255 2 Mbit/s Data Rate Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 RDO/RSIG 4 Mbit/s Data Rate (SCLKR = 8.192 MHz) Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 255 RDO/RSIG Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 4 Mbit/s Data Rate (SCLKR = 8.192 MHz) DLR marks any Sa Bit Sa-Bit Marker XC0 . SA8E-SA4E 4 Mbit Interface RFM Receive Frame Marker RC0/1 2 Mbit Interface 4 Mbit Interface marks any bit position 2 Mbit Interface RSIGM marks any Time-Slot Time-Slot Marker RTR1...4 1) only falling trigger edge shown, depending on Bit SIC3.RESR Figure 28 Data Sheet ITD10951 Receive System Interface Clocking (E1) 105 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.5.1.1 Receive Offset Programming Depending on the selection of the synchronization signals (SYPR or RFM), different calculation formulas are used to define the position of the synchronization pulses. These formulas are given below, see Figure 29 to Figure 32 for explanation. The pulse length of SYPR and RFM is always the basic E1 bit width (488 ns), independent of the selected system highway clock and data frequency. SYPR Offset Calculation T: Time between beginning of SYPR pulse and beginning of next frame (time slot 0, bit 0), measured in number of SCLKR clock intervals maximum delay: Tmax = (256 × SC/SD) - 1 SD: Basic data rate; 2.048 Mbit/s SC: System clock rate; 2.048, 4.096, 8.192, or 16.384 MHz X: Programming value to be written to registers RC0 and RC1 (see page 239). 0 ≤ T ≤ 4: X=4-T 5 ≤ T ≤ Tmax: X = 2052 - T RFM Offset Calculation MP: Marker position of RFM, counting in SCLKR clock cycles (0 = bit 1, time slot 0, channel phase 0) SC = 2.048 MHz: SC = 4.096 MHz: SC = 8.192 MHz: SC = 16.384 MHz: 0 ≤ MP ≤ 255 0 ≤ MP ≤ 511 0 ≤ MP ≤ 1023 0 ≤ MP ≤ 2047 SD: Basic data rate; 2.048 Mbit/s SC: System clock rate; 2.048, 4.096, 8.192, or 16.384 MHz X: Programming value to be written to registers RC0 and RC1 (see page 239). 0 ≤ MP ≤ 2045: 2046 ≤ MP ≤ 2047: Data Sheet X = MP + 2 X = MP - 2046 106 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 TS0 RDO TS1 TS31 1234567 812345678 TS0 TS1 1234567812 34567812345678 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) SYPR T=0 256 - T T SYPR T SYPR F0221A Figure 29 SYPR Offset Programming (2.048 Mbit/s, 2.048 MHz) TS0 - CP0 RDO (CP0) RDO (CP1) TS0 - CP1 TS31-CP3 1234567 8 TS0 - CP0 TS0 - CP1 12 345678 12345678 RDO (CP3) 12345678 12345678 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) SYPR T=0 SC/SD x 256 - T T SYPR T SYPR (TS = time slot, CP = channel phase) Figure 30 Data Sheet F0221B SYPR Offset Programming (8.192 Mbit/s, 8.192 MHz) 107 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 TS0 RDO TS1 TS31 1234567 812345678 TS0 TS1 1234567812 34567812345678 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) RFM BP = 0 RFM BP = 12 RFM BP = 251 F0221C Figure 31 RFM Offset Programming (2.048 Mbit/s, 2.048 MHz) TS0 - CP0 RDO (CP0) RDO (CP1) TS0 - CP1 TS31-CP3 1234567 8 TS0 - CP0 TS0 - CP1 12 345678 12345678 RDO (CP3) 12345678 12345678 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) RFM BP = 0 RFM BP = 12 RFM BP = 1020 Figure 32 Data Sheet byte-interleaved (TS = time slot, CP = channel phase) F0221D RFM Offset Programming (8.192 Mbit/s, 8.192 MHz) 108 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.5.2 Transmit System Interface (E1) Multi Frame 1 XDI FRAME0 FRAME1 FRAME2 Multi Frame 2 FRAME15 FRAME0 FRAME1 FRAME2 XMFB XMFS SYPX Bit 0 Sample Edge 1) Trigger Edge 1) SYPX T 2) SCLKX XSIGM XDI/XSIG Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 TS0 DLX Bit 4 marked Sa-Bit Marker XC0.SA8E-SA4E 1) 2) Figure 33 Data Sheet only falling edge mode shown delay T is programmable by XC0/1; F0003 Transmit System Interface Clocking: 2.048 MHz (E1) 109 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 Multi Frame 1 XDI FRAME0 FRAME1 FRAME2 Multi Frame 2 FRAME15 FRAME0 FRAME1 FRAME2 XMFB XMFS SYPX Bit 0 Sample Edge 1) Trigger Edge 1) SYPX T 2) SCLKX XSIGM Time-Slot Marker TTR1...4 SIC2.SICS2-0=000 XDI/XSIG3) 1 SIC2.SICS2-0=000 2 3 4 5 XDI/XSIG3) 6 7 8 1 SIC2.SICS2-0=001 2 3 4 5 6 7 8 DLX Sa-Bit Marker XC0.SA8E-SA4E SIC2.SICS2-0=000 Bit 4 marked DLX Sa-Bit Marker XC0.SA8E-SA4E SIC2.SICS2-0=000 1) only falling edge mode shown 2) delay T is programmable by XC0/1; 3) data 4.096 Mbit/s, clock 8.192 MHz Figure 34 Data Sheet Bit 4 marked F0004 Transmit System Interface Clocking: 8.192 MHz/4.096 Mbit/s (E1) 110 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.5.2.1 Transmit Offset Programming The pulse length of SYPX is always the basic E1 bit width (488 ns), independent of the selected system highway clock and data frequency. SYPX Offset Calculation T: Time between beginning of SYPX pulse and beginning of next frame (time slot 0, bit 0), measured in number of SCLKX clock intervals maximum delay: Tmax = (256 × SC/SD) - 1 SD: Basic data rate; 2.048 Mbit/s SC: System clock rate; 2.048, 4.096, 8.192, or 16.384 MHz X: Programming value to be written to registers XC0 and XC1 (see page 237). 0 ≤ T ≤ 4: X=4-T 5 ≤ T ≤ Tmax: X = 256 × SC/SD - T + 4 Data Sheet 111 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 TS0 XDI TS1 TS31 12 3 4 5 6 7 8 1 2 3 4 5 6 7 8 TS0 TS1 1 2 3 4 5 67 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SCLKX SIC3.RESX = 1 (rising edge) SCLKX SIC3.RESX = 0 (falling edge) SYPX T=0 256 - T T SYPX T SYPX F0223A Figure 35 SYPX Offset Programming (2.048 Mbit/s, 2.048 MHz) TS0 - CP0 XDI (CP0) XDI (CP1) TS0 - CP1 TS31-CP3 1 23 4 5 6 7 8 TS0 - CP0 TS0 - CP1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 XDI (CP3) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SCLKX SIC3.RESX = 1 (rising edge) SCLKX SIC3.RESX = 0 (falling edge) SYPX T=0 SC/SD x 256 - T T SYPX T SYPX Figure 36 Data Sheet (TS = time slot, CP = channel phase) F0223B SYPX Offset Programming (8.192 Mbit/s, 8.192 MHz) 112 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.5.3 Time Slot Assigner (E1) HDLC channel 1 offers the flexibility to connect data during certain time slots, as defined by registers RTR(4:1) and TTR(4:1), to the RFIFO and XFIFO, respectively. Any combinations of time slots can be programmed for the receive and transmit directions. If CCR1.EITS = 1 the selected time slots (RTR(4:1)) are stored in the RFIFO of the signaling controller and the XFIFO contents is inserted into the transmit path as controlled by registers TTR(4:1). For HDLC channels 2 and 3, one out of 31 time slots can be selected for each channel, but in common for transmit and receive direction. Within selected time slots single bit positions can be masked to be used/not used for HDLC transmission for all HDLC channels. Additionally, the use of even, odd or both frames can be selected for each HDLC channel individually. Table 24 Time Slot Assigner HDLC Channel 1 (E1) Receive Time Slot Register Transmit Time Slot Register Time Slots Receive Time Slot Register Transmit Time Slot Register Time Slots RTR 1.7 TTR 1.7 0 RTR 3.7 TTR 3.7 16 RTR 1.6 TTR 1.6 1 RTR 3.6 TTR 3.6 17 RTR 1.5 TTR 1.5 2 RTR 3.5 TTR 3.5 18 RTR 1.4 TTR 1.4 3 RTR 3.4 TTR 3.4 19 RTR 1.3 TTR 1.3 4 RTR 3.3 TTR 3.3 20 RTR 1.2 TTR 1.2 5 RTR 3.2 TTR 3.2 21 RTR 1.1 TTR 1.1 6 RTR 3.1 TTR 3.1 22 RTR 1.0 TTR 1.0 7 RTR 3.0 TTR 3.0 23 RTR 2.7 TTR 2.7 8 RTR 4.7 TTR 4.7 24 RTR 2.6 TTR 2.6 9 RTR 4.6 TTR 4.6 25 RTR 2.5 TTR 2.5 10 RTR 4.5 TTR 4.5 26 RTR 2.4 TTR 2.4 11 RTR 4.4 TTR 4.4 27 RTR 2.3 TTR 2.3 12 RTR 4.3 TTR 4.3 28 RTR 2.2 TTR 2.2 13 RTR 4.2 TTR 4.2 29 RTR 2.1 TTR 2.1 14 RTR 4.1 TTR 4.1 30 RTR 2.0 TTR 2.0 15 RTR 4.0 TTR 4.0 31 Data Sheet 113 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.6 Test Functions (E1) 4.6.1 Pseudo-Random Binary Sequence Generation and Monitor The FALC56 has the ability to generate and monitor 215-1 and 220-1 pseudo-random binary sequences (PRBS). The generated PRBS pattern is transmitted to the remote end on pins XL1/2 or XDOP/N and can be inverted optionally. Generating and monitoring of PRBS pattern is done according to ITU-T O.151. The PRBS monitor senses the PRBS pattern in the incoming data stream. Synchronization is done on the inverted and non-inverted PRBS pattern. The current synchronization status is reported in status and interrupt status registers. Enabled by bit LCR1.EPRM each PRBS bit error increments an error counter (CEC2). Synchronization is reached within 400 ms with a probability of 99.9% at a bit error rate of up to 10-1. The PRBS generator and monitor can be used to handle either a framed (TPC0.FRA = 1) or an unframed (TPC0.FRA = 0) data stream. 4.6.2 Remote Loop In the remote loop-back mode the clock and data recovered from the line inputs RL1/2 or RDIP/RDIN are routed back to the line outputs XL1/2 or XDOP/XDON through the analog or digital transmitter. As in normal mode they are also processed by the synchronizer and then sent to the system interface. The remote loop-back mode is selected by setting the corresponding control bits LIM1.RL and LIM1.JATT. Received data can be looped with or without the transmit jitter attenuator (FIFO). RCLK RL1 RL2 Clock + Data Recovery Rec. Framer Elast. Store RDO Trans. Framer Elast. Store XDI FIFO XL1 MUX XL2 XCLK Figure 37 Data Sheet MUX RCLK DCO-R/X ITS09750 Remote Loop (E1) 114 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.6.3 Payload Loop-Back To perform an effective circuit test a payload loop is implemented. The payload loopback (FMR2.PLB) loops the data stream from the receiver section back to transmitter section. The looped data passes the complete receiver including the wander and jitter compensation in the receive elastic store and is output on pin RDO. Instead of the data an AIS signal (FMR2.SAIS) can be sent to the system interface. The framing bits, CRC4 and spare bits are not looped, if XSP.TT0 = 0. They are generated by the FALC56 transmitter. If the PLB is enabled the transmitter and the data on pins XL1/2 or XDOP/XDON are clocked with SCLKR instead of SCLKX. If XSP.TT0 = 1 the received time slot 0 is sent back transparently to the line interface. Data on the following pins is ignored: XDI, XSIG, SCLKX, SYPX and XMFS. All the received data is processed normally. RCLK RL1 RL2 AIS-GEN MUX Clock + Data Recovery Rec. Framer Elast. Store RDO SCLKR XL1 XL2 Elast. Store Trans. Framer XDI SCLKX ITS09748 Figure 38 Data Sheet Payload Loop (E1) 115 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.6.4 Local Loop The local loop-back mode selected by LIM0.LL = 1 disconnects the receive lines RL1/2 or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data provided by the system interface is routed through the analog receiver back to the system interface. However, the bit stream is transmitted undisturbedly on the line. However, an AIS to the distant end can be enabled by setting FMR1.XAIS = 1 without influencing the data looped back to the system interface. Note that enabling the local loop usually invokes an out-of-frame error until the receiver resynchronizes to the new framing. The serial codes for transmitter and receiver have to be identical. RCLK RL2 Clock + Data Recovery Rec. Framer Elast. Store RDO XL1 MUX Trans. Framer Elast. Store XDI RL1 XL2 AIS-GEN ITS09749 Figure 39 Data Sheet Local Loop (E1) 116 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.6.5 Single Channel Loop-Back Each of the 32 time slots can be selected for loop-back from the system PCM input (XDI) to the system PCM output (RDO). This loop-back is programmed for one time slot at a time selected by register LOOP. During loop-back, an idle channel code programmed in register IDLE is transmitted to the remote end in the corresponding PCM route time slot. For the time slot test, sending sequences of test patterns like a 1-kHz check signal shall be avoided. Otherwise an increased occurrence of slips in the tested time slot disturbs testing. These slips do not influence the other time slots and the function of the receive memory. The usage of a quasi-static test pattern is recommended. RCLK RL1 RL2 XL1 XL2 Clock + Data Recovery Trans. Framer MUX Rec. Framer MUX IDLE Code Figure 40 Data Sheet Elast. Store RDO Elast. Store XDI ITS09747 Single Channel Loop-Back (E1) 117 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description E1 4.6.6 Alarm Simulation (E1) Alarm simulation does not affect the normal operation of the device, i.e. all time slots remain available for transmission. However, possible real alarm conditions are not reported to the processor or to the remote end when the device is in the alarm simulation mode. The alarm simulation is initiated by setting the bit FMR0.SIM. The following alarms are simulated: • • • • • • • • • • • Loss-Of-Signal (LOS) Alarm Indication Signal (AIS) Loss of pulse frame Remote alarm indication Receive and transmit slip indication Framing error counter Code violation counter (HDB3 Code) CRC4 error counter E-Bit error counter CEC2 counter CEC3 counter Some of the above indications are only simulated if the FALC56 is configured to a mode where the alarm is applicable (e.g. no CRC4 error simulation when doubleframe format is enabled). Setting of the bit FMR0.SIM initiates alarm simulation, interrupt status bits are set. Error counting and indication occurs while this bit is set. After it is reset all simulated error conditions disappear, but the generated interrupt statuses are still pending until the corresponding interrupt status register is read. Alarms like AIS and LOS are cleared automatically. Interrupt status registers and error counters are automatically cleared on read. 4.6.7 Single Bit Defect Insertion Single bit defects can be inserted into the transmit data stream for the following functions: FAS defect, multiframe defect, CRC defect, CAS defect, PRBS defect and bipolar violation. Defect insertion is controlled by register IERR. Data Sheet 118 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5 Functional Description T1/J1 5.1 Receive Path in T1/J1 Mode RL1/RDIP/ROID RL2/RDIN/RCLKI Clock & Data Recovery DPLL Equalizer Analog LOS Detector Line Decoder Alarm Detector DCO-R Receive Jitter Attenuator SYNC RDATA RCLK Receive System Interface FSC F0117 MCLK Figure 41 5.1.1 Receive Clock System (T1/J1) Receive Line Interface (T1/J1) For data input, three different data types are supported: • Ternary coded signals received at multifunction ports RL1 and RL2 from a -36 dB ternary interface. The ternary interface is selected if LIM1.DRS is reset. • Digital dual-rail signals received on ports RDIP and RDIN. The dual-rail interface is selected if LIM1.DRS and FMR0.RC1 is set. • Unipolar data on port ROID received from a fiber-optical interface. The optical interface is selected if LIM1.DRS is set and FMR0.RC1 is reset. 5.1.2 Receive Short and Long-Haul Interface (T1/J1) The FALC56 has an integrated short-haul and long-haul line interface, including a receive equalization network, noise filtering and programmable line build-outs (LBO). Data Sheet 119 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.1.3 Receive Equalization Network (T1/J1) The FALC56 automatically recovers the signals received on pins RL1/2. The maximum reachable length with a 22 AWG twisted-pair cable is 2000 m (~6560 ft.). After reset the FALC56 is in short-haul mode, received signals are recovered up to -10 dB of cable attenuation. Switching into long-haul mode is done by setting of bit LIM0.EQON = 1. The integrated receive equalization network recovers signals with up to -36 dB of cable attenuation in long-haul mode. Noise filters eliminate the higher frequency part of the received signals. The incoming data is peak-detected and sliced to produce the digital data stream. The slicing level is software selectable in four steps (45%, 50%, 55%, 67%). The received data is then forwarded to the clock and data recovery unit. 5.1.4 Receive Line Attenuation Indication (T1/J1) Status register RES reports the current receive line attenuation in a range from 0 to -36 dB in 25 steps of approximately 1.4 dB each. The least significant 5 bits of this register indicate the cable attenuation in dB. These 5 bits are only valid in combination with the most significant two bits (RES.EV1/0 = 01). 5.1.5 Receive Clock and Data Recovery (T1/J1) The analog received signal on port RL1/2 is equalized and then peak-detected to produce a digital signal. The digital received signal on port RDIP/N is directly forwarded to the DPLL. The receive clock and data recovery extracts the route clock RCLK from the data stream received at the RL1/2, RDIP/RDIN or ROID lines and converts the data stream into a single-rail, unipolar bit stream. The clock and data recovery uses an internally generated high frequency clock based on MCLK. The recovered route clock or a de-jittered clock can be output on pin RCLK as shown in Table 25. See also Table 28 on page 126 for details of master/slave clocking. Data Sheet 120 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Table 25 RCLK Output Selection (T1/J1) Clock Source RCLK Frequency CMR1. CMR1. SIC2. DCS RS1/0 SSC2 Receive Data (1.544 Mbit/s on RL1/RL2, RDIP/RDIN or ROID) 1.544 MHz X 00 X Receive Data in case of LOS constant high X 01 X 1.544 MHz (generated by DCO-R, synchronized on SYNC) 1 10 1 DCO-R 1.544 MHz X 10 1 2.048 MHz X 10 0 6.176 MHz X 11 1 8.192 MHz X 11 0 The intrinsic jitter generated in the absence of any input jitter is not more than 0.035 UI. In digital bipolar line interface mode the clock and data recovery requires HDB3 coded signals with 50% duty cycle. 5.1.6 Receive Line Coding (T1/J1) The B8ZS line code or the AMI (ZCS, zero code suppression) coding is provided for the data received from the ternary or the dual-rail interface. All code violations that do not correspond to zero substitution rules are detected. The detected errors increment the code violation counter (16 bits length). In case of the optical interface a selection between the NRZ code and the CMI Code (1T2B) with B8ZS or AMI postprocessing is provided. If CMI code is selected the receive route clock is recovered from the data stream. The CMI decoder does not correct any errors. In case of NRZ coding data is latched with the falling edge RCLKI. When using the optical interface with NRZ coding, the decoder is bypassed and no code violations are detected. Additionally, the receive line interface contains the alarm detection for Alarm Indication Signal AIS (Blue Alarm) and the loss-of-signal LOS (Red Alarm). The signal at the ternary interface is received at both ends of a transformer. Data Sheet 121 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 RL1 Line t2 t1 R R2 FALC RL2 ITS10967 Figure 42 Receiver Configuration (T1/J1) Table 26 Recommended Receiver Configuration Values (T1/J1) Characteristic Impedance [Ω] Parameter1) R2 (± 1%) [Ω] t2 : t1 1) T1 J1 100 110 1:1 This includes all parasitic effects caused by circuit board design. Data Sheet 122 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.1.7 Receive Line Monitoring Mode For short-haul applications like shown in Figure 43, the receive equalizer can be switched into receive line monitoring mode (LIM0.RLM = 1). One device is used as a short-haul receiver while the other is used as a short-haul monitor. In this mode the receiver sensitivity is increased to detect an incoming signal of -20 dB resistive attenuation. The required resistor values are given in Table 27. t2 : t1 RL1 E1/T1/J1 Receive Line R1 FALC® (Receiver) RL2 LIM0.RLM=0 R3 R3 t2 : t1 RL1 FALC® (Monitor) R2 RL2 resistive -20 dB network LIM0.RLM=1 F0074 Figure 43 Receive Line Monitoring Table 27 External Component Recommendations (Monitoring) Parameter1) R1 (± 1 %) [Ω] R2 (± 1 %) [Ω] R3 (± 1 %) [Ω] t2 : t1 1) Characteristic Impedance [Ω] T1 J1 100 110 100 110 100 110 430 470 1:1 1:1 This includes all parasitic effects caused by circuit board design. Using the receive line monitor mode and the hardware tristate function of transmit lines XL1/2, the FALC56 now supports applications connecting two devices to one receive Data Sheet 123 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 and transmission line. In these kind of applications both devices are working in parallel for redundancy purpose (see Figure 44). While one of them is driving the line, the other one must be switched into transmit line tristate mode. If both channels are configured identically and supplied with the same system data and clocks, the transmit path can be switched from one channel to the other without causing a synchronization loss at the remote end. XL1 E1/T1/J1 Transmit Line XDI XL2 RL1 FALC® (active) E1/T1/J1 Receive Line RDO RL2 TRIST 1 XL1 XDI XL2 RL1 FALC® (stand by) RDO RL2 TRIST F0075 Figure 44 5.1.8 Protection Switching Application Loss-of-Signal Detection (T1/J1) There are different definitions for detecting Loss-Of-Signal alarms (LOS) in the ITU-T G.775 and AT&T TR 54016. The FALC56 covers all these standards. The LOS indication is performed by generating an interrupt (if not masked) and activating a status bit. Additionally a LOS status change interrupt is programmable by register GCR.SCI. Data Sheet 124 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 • Detection: An alarm is generated if the incoming data stream has no pulses (no transitions) for a certain number (N) of consecutive pulse periods. “No pulse” in the digital receive interface means a logical zero on pins RDIP/RDIN or ROID. A pulse with an amplitude less than Q dB below nominal is the criteria for “no pulse” in the analog receive interface (LIM1.DRS = 0). The receive signal level Q is programmable by three control bits LIM1.RIL(2:0) (see Chapter 11.3 on page 447). The number N is set by an 8 bit register (PCD). The contents of the PCD register is multiplied by 16, which results in the number of pulse periods, i.e. the time which has to suspend until the alarm has to be detected. The programmable range is 16 to 4096 pulse periods. • Recovery: In general the recovery procedure starts after detecting a logical "1" (digital receive interface) or a pulse (analog receive interface) with an amplitude more than Q dB (defined by LIM1.RIL(2:0)) of the nominal pulse. The value in the 8 bit register PCR defines the number of pulses (1 to 255) to clear the LOS alarm. Additional recovery conditions are programmed by register LIM2. If a loss-of-signal condition is detected in long-haul mode, the data stream can optionally be cleared automatically to avoid bit errors before LOS is indicated. The selection is done by LIM1.CLOS = 1. 5.1.9 Receive Jitter Attenuator (T1/J1) The receive jitter attenuator is placed in the receive path. The working clock is an internally generated high frequency clock based on the clock provided on pin MCLK. The jitter attenuator meets the requirements of PUB 62411, PUB 43802, TR-TSY 009,TRTSY 253, TR-TSY 499 and ITU-T I.431, G.703 and G. 824. The internal PLL circuitry DCO-R generates a "jitter-free" output clock which is directly depending on the phase difference of the incoming clock and the jitter attenuated clock.The receive jitter attenuator can be synchronized either on the extracted receive clock RCLK or on a 1.544-, 2.048-MHz or 8-kHz clock provided on pin SYNC (8 kHz in master mode only). The received data is written into the receive elastic buffer with RCLK and are read out with the de-jittered clock sourced by DCO-R. The jitter attenuated clock can be output on pins RCLK, CLK1 or SCLKR. Optionally an 8-kHz clock is provided on pin SEC/FSC. The DCO-R circuitry attenuates the incoming jittered clock starting at 6-Hz jitter frequency with 20 dB per decade fall-off. Wander with a jitter frequency below 6 Hz is passed unattenuated. The intrinsic jitter in the absence of any input jitter is < 0.02 UI. For some applications it might be useful starting of jitter attenuation at lower frequencies. Therefore the corner frequency is switchable by the factor of ten down to 0.6 Hz (LIM2.SCF). The DCO-R circuitry is automatically centered to the nominal bit rate if the reference clock on pin SYNC/RCLK is missed for 2, 3 or 4 of the 2.048-MHz or 1.544-MHz clock Data Sheet 125 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 periods. This center function of DCO-R can be optionally disabled (CMR2.DCF = 1) in order to accept a gapped reference clock. In analog line interface mode the RCLK is always running. Only in digital line interface mode with single-rail data (NRZ) a gapped clock on pin RCLK can occur. The receive jitter attenuator works in two different modes: • Slave mode In slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the recovered route clock. In case of LOS the DCO-R switches automatically to master mode. If bit CMR1.DCS is set automatic switching from RCLK to SYNC is disabled. • Master mode In master mode (LIM0.MAS = 1) the jitter attenuator is in free running mode if no clock is supplied on pin SYNC. If an external clock on the SYNC input is applied, the DCOR synchronizes to this input. The external frequency can be 1.544 MHz (LIM1.DCOC = 0; IPC.SSYF = 0), 2.048 MHz (LIM1.DCOC = 1; IPC.SSYF = 0) or 8.0 kHz (IPC.SSYF = 1; LIM1.DCOC = don’t care). The following table shows the clock modes with the corresponding synchronization sources. Table 28 System Clocking (T1/J1) Mode Internal SYNC LOS Active Input System Clocks Master independent Fixed to VDD DCO-R centered, if CMR2.DCF = 0. (CMR2.DCF should not be set) Master independent 1.544 MHz Synchronized on SYNC input (external 1.544 MHz, IPC.SSYF = 0, LIM1.DCOC = 0) Master independent 2.048 MHz Synchronized on SYNC input (external 2.048 MHz, IPC.SSYF = 0, LIM1.DCOC = 1) Master independent 8.0 kHz Synchronized on SYNC input (external 8.0 kHz, IPC.SSYF = 1, CMR2.DCF = 0) Slave no Fixed to VDD Synchronized on line RCLK Slave no 1.544 or Synchronized on line RCLK 2.048 MHz Data Sheet 126 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Table 28 System Clocking (T1/J1) (cont’d) Mode Internal SYNC LOS Active Input System Clocks Slave yes CMR1.DCS = 0: DCO-R is centered, if CMR2.DCF = 0. (CMR2.DCF should not be set) Fixed to VDD CMR1.DCS = 1: Synchronized on line RCLK Slave yes 1.544 or CMR1.DCS = 0: 2.048 MHz Synchronized on SYNC input (external 1.544 or 2.048 MHz) CMR1.DCS = 1: Synchronized on line clock RCLK The jitter attenuator meets the jitter transfer requirements of the PUB 62411, PUB 43802, TR-TSY 009,TR-TSY 253, TR-TSY 499 and ITU-T I.431 and G.703 (refer to Figure 45). ITD10314 10 dB 0 PUB 62411_H PUB 62411_L FALC R Attenuation -10 Slope - 20 dB/Decade -20 -30 Slope - 40 dB/Decade -40 -50 -60 -70 1 10 100 1000 10000 Hz 100000 Frequency Figure 45 Data Sheet Jitter Attenuation Performance (T1/J1) 127 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.1.10 Jitter Tolerance (T1/J1) The FALC56 receiver’s tolerance to input jitter complies with ITU, AT&T and Telcordia requirements for T1 applications. Figure 46 shows the curves of different input jitter specifications stated below as well as the FALC56 performance. 1000 PUB 62411 TR-NWT 000499 Cat II CCITT G.823 ITU-T I.431 FALC® UI Jitter Amplitude 100 10 1 0.1 1 10 100 1000 Jitter Frequency Figure 46 Data Sheet 10000 Hz 100000 F0025 Jitter Tolerance (T1/J1) 128 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.1.11 Output Jitter (T1/J1) According to the input jitter defined by PUB62411 the FALC56 generates the output jitter, which is specified in Table 29 below. Table 29 Output Jitter (T1/J1) Specification PUB 62411 Measurement Filter Bandwidth Lower Cutoff Upper Cutoff Output Jitter (UI peak to peak) 10 Hz 8 kHz < 0.015 8 kHz 40 kHz < 0.015 10 Hz 40 kHz < 0.015 Broadband 5.1.12 < 0.02 Framer/Synchronizer (T1/J1) The following functions are performed: • Synchronization on pulse frame and multiframe • Error indication when synchronization is lost. In this case, AIS is sent to the system side automatically and remote alarm to the remote end if enabled. • Initiating and controlling of resynchronization after reaching the asynchronous state. This is done automatically by the FALC56 or user controlled by the microprocessor interface. • Detection of remote alarm (yellow alarm) indication from the incoming data stream. • Separation of service bits and data link bits. This information is stored in special status registers. • Detection of framed or unframed in-band loop-up/-down code • Generation of various maskable interrupt statuses of the receiver functions. • Generation of control signals to synchronize the CRC checker, and the receive elastic buffer. If programmed and applicable to the selected multiframe format, CRC checking of the incoming data stream is done by generating check bits for a CRC multiframe according to the CRC6 procedure (refer to ITU-T G.704). These bits are compared with those check bits that are received during the next CRC multiframe. If there is at least one mismatch, the CRC error counter (16 bit) is incremented. 5.1.13 Receive Elastic Buffer (T1/J1) The received bit stream is stored in the receive elastic buffer. The memory is organized as a two-frame elastic buffer with a maximum size of 2 × 193 bit. The size of the elastic buffer is configured independently for the receive and transmit direction. Programming of the receive buffer size is done by SIC1.RBS1/0: Data Sheet 129 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 • RBS1/0 = 00: two frame buffer or 386 bits Maximum of wander amplitude (peak-to-peak): (1 UI = 648 ns) System interface clocking rate: modulo 2.048 MHz: 142 UI in channel translation mode 0 78 UI in channel translation mode 1 System interface clocking rate: modulo 1.544 MHz: Maximum of wander: 140 UI average delay after performing a slip: 1 frame or 193 bits • RBS1/0 = 01: one frame buffer or 193 bits System interface clocking rate: modulo 2.048 MHz: Maximum of wander: 70 UI in channel translation mode 0 Maximum of wander: 50 UI in channel translation mode 1 System interface clocking rate: modulo 1.544 MHz: Maximum of wander: 74 UI average delay after performing a slip: 96 bits • RBS1/0 = 10: short buffer or 96 bits System interface clocking rate: modulo 2.048 MHz: Maximum of wander: 28 UI in channel translation mode 0; channel translation mode 1 not supported System interface clocking rate: modulo 1.544 MHz: Maximum of wander: 38 UI average delay after performing a slip: 48 bits • RBS1/0 = 11: Bypass of the receive elastic buffer The functions are: • Clock adaption between system clock (SCLKR) and internally generated route clock (RCLK). • Compensation of input wander and jitter. • Frame alignment between system frame and receive route frame • Reporting and controlling of slips Controlled by special signals generated by the receiver, the unipolar bit stream is converted into bit-parallel, time slot serial data which is circularly written to the elastic buffer using internally generated Receive Route Clock (RCLK). Reading of stored data is controlled by the system clock sourced by SCLKR or by the receive jitter attenuator and the synchronization pulse (SYPR) together with the programmed offset values for the receive time slot/clock slot counters. After conversion into a serial data stream, the data is sent out on port RDO. If the receive buffer is bypassed programming of the time slot offset is disabled and data is clocked off with RCLK instead of SCLKR. Data Sheet 130 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 The 24 received time slots (T1/J1) can be translated into the 32 system time slots (E1) in two different channel translation modes (FMR1.CTM). Unequipped time slots are set to FFH. See Table 30. Table 30 Channel Translation Modes (DS1/J1) Channels Time Slots Channel Translation Mode 0 Channel Translation Mode 1 FS/DL FS/DL 1 Channels Time Slots Channel Translation Mode 0 Channel Translation Mode 1 0 – 16 16 1 1 13 17 17 2 2 2 14 18 18 3 3 3 15 19 19 – 4 4 – 20 20 4 5 5 16 21 21 5 6 6 17 22 22 6 7 7 18 23 23 – 8 8 – 24 24 7 9 9 19 – 25 8 10 10 20 – 26 9 11 11 21 – 27 – 12 12 – – 28 10 13 13 22 – 29 11 14 14 23 – 30 12 15 15 24 – 31 – : FFH In one frame or short buffer mode the delay through the receive buffer is reduced to an average delay of 96 or 48 bits. In bypass mode the time slot assigner is disabled. In this case SYPR programmed as input is ignored. Slips are performed in all buffer modes except the bypass mode. After a slip is detected the read pointer is adjusted to one half of the current buffer size. The following table gives an overview of the receive buffer operating mode. Data Sheet 131 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Table 31 Receive Buffer Operation Modes (T1/J1) Buffer Size (SIC1.RBS1/0) TS Offset program. (RC1/0) + SYPR = input Slip perform. bypass1) disabled no short buffer not recommended, recommended: SYPR = output yes 1 frame not recommended, recommended: SYPR = output yes 2 frames enabled yes 1) In bypass mode the clock provided on pin SCLKR is ignored. Clocking is done with RCLK. Figure 47 gives an idea of operation of the receive elastic buffer: A slip condition is detected when the write pointer (W) and the read pointer (R) of the memory are nearly coincident, i.e. the read pointer is within the slip limits (S +, S –). If a slip condition is detected, a negative slip (one frame or one half of the current buffer size is skipped) or a positive slip (one frame or one half of the current buffer size is read out twice) is performed at the system interface, depending on the difference between RCLK and the current working clock of the receive backplane interface, i.e. on the position of pointer R and W within the memory. A positive/negative slip is indicated by the interrupt status bits ISR3.RSP and ISR3.RSN. Data Sheet 132 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Frame 2 Time Slots R’ R Slip S- S+ W Frame 1 Time Slots Moment of Slip Detection W : Write Pointer (Route Clock controlled) R : Read Pointer (System Clock controlled) S+, S- : Limits for Slip Detection (mode dependent) ITD10952 Figure 47 Data Sheet The Receive Elastic Buffer as Circularly Organized Memory 133 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.1.14 Receive Signaling Controller (T1/J1) The signaling controller can be programmed to operate in various signaling modes. The FALC56 performs the following signaling and data link methods. 5.1.14.1 HDLC or LAPD access The FALC56 offers three independent HDLC channels. All of them provide the following features: • 64 byte receive FIFO for each channel • 64 byte transmit FIFO for each channel • transmission in one of 24 time slots (time slot number programmable for each channel individually) • transmission in even frames only, odd frames only or both (programmable for each channel individually) • bit positions to be used in selected time slots are maskable (any bit position can be enabled for each channel individually) • HDLC or transparent mode • flag detection • CRC checking • bit-stuffing • flexible address recognition (1 byte, 2 bytes) • C/R bit processing (according to LAPD protocol) In addition to this, HDLC channel 1 provides: • SS7 support • BOM (bit oriented message) support • flexibility to insert and extract data during certain time slots, any combination of time slots can be programmed independently for the receive and transmit direction In case of common channel signaling the signaling procedure HDLC/SDLC or LAPD according to Q.921 is supported. The signaling controller of the FALC56 performs the flag detection, CRC checking, address comparison and zero bit removing. The received data flow and the address recognition features can be performed in very flexible way, to satisfy almost any practical requirements. Depending on the selected address mode, the FALC56 performs a 1 or 2-byte address recognition. If a 2-byte address field is selected, the high address byte is compared with the fixed value FEH or FCH (group address) as well as with two individually programmable values in RAH1 and RAH2 registers. According to the ISDN LAPD protocol, bit 1 of the high byte address is interpreted as command/response bit (C/R) and is excluded from the address comparison. Buffering of receive data is done in a 64 byte deep RFIFO. In signaling controller transparent mode, fully transparent data reception without HDLC Data Sheet 134 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 framing is performed, i.e. without flag recognition, CRC checking or bit stuffing. This allows user specific protocol variations. 5.1.14.2 Support of Signaling System #7 The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is described in ITU-Q.703. The following description assumes, that the reader is familiar with the SS7 protocol definition. SS7 support must be activated by setting the MODE register. The SS7 protocol is supported by the following hardware features in receive mode: • • • • • all Signaling Units (SU) are stored in the receive FIFO (RFIFO) detecting of flags from the incoming data stream bit stuffing (zero deletion) checking of seven or more consecutive ones in the receive data stream checking if the received Signaling Unit is a multiple of eight bits and at least six octets including the opening flag • calculation of the CRC16 checksum: In receive direction the calculated checksum is compared to the received one; errors are reported in register RSIS. • checking if the signal information field of a received signaling unit consists of more than 272 octets, in this case the current signaling unit is discarded. In order to reduce the microprocessor load, fill In signaling units (FISUs) are processed automatically. By examining the length indicator of a received signal unit the FALC56 decides whether a FISU has been received. Consecutively received FISUs are compared and optionally not stored in the receive FIFO (RFIFO, 2×32 bytes), if the contents is equal to the previous one. The same applies to link status signaling units, if bit CCR5.CSF is set. The different types of signaling units as message signaling unit (MSU), link status signaling unit (LSSU) and fill in signaling units (FISU) are indicated in the RSIS register, which is automatically added to the RFIFO with each received signaling unit. The complete signaling unit except start and end flags is stored in the receive FIFO. The functions of bits CCR1.RCRC and CCR1.RADD are still valid in SS7 mode. Errored signaling units are handled automatically according to ITU-T Q.703 as shown in Figure 20. SU counter (su) and errored SU counter (Cs) are reset by setting CMDR2.RSUC. The error threshold T can be selected to be 64 (default) or 32 by setting/ clearing bit CCR5.SUET. If the defined error limit is exceeded, an interrupt (ISR1.SUEX) is generated, if not masked by IMR1.SUEX = 1. Note: If SUEX is caused by an aborted/invalid frame, the interrupt will be issued regularly until a valid frame is received (e.g. a FISU). Data Sheet 135 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Idle Reset Counter values Cs := 0 su := 0 [CMDR2.RSUC = 1] in service N SU in error? Y Cs := Cs + 1 su := su + 1 Cs = T ? su := su + 1 N N Y su = 256 ? Y Link failure [ISR1.SUEX = 1] su := 0 Idle Cs = 0 ? Y N Notes: su: signaling units counter Cs: errored signaling units counter T: error threshold (64 or 32), selectable by CCR5.SUET Figure 48 Data Sheet Cs := Cs -1 in service F0071 Automatic Handling of Errored Signaling Units 136 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.1.14.3 CAS Bit-Robbing (T1/J1, serial mode) The signaling information is carried in the LSB of every sixth frame for each time slot. The signaling controller samples the bit stream either on the receive line side or if external signaling is enabled on the receive system side on port RSIG. Receive signaling data is stored in the registers RS(12:1). Optionally the complete CAS multiframe is transmitted on pin RSIG (FMR5.EIBR = 1). The signaling data is clocked out with the working clock of the receive highway (SCLKR) together with the receive synchronization pulse (SYPR). Data on RSIG is transmitted in the last 4 bits per time slot and are time slot aligned to the data on RDO. In ESF format the A,B,C,D bits are placed in the bit positions 5 to 8 per time slot. In F12/72 format the A and B bits are repeated in the C and D bit positions. The first 4 bits per time slot can be optionally fixed high or low. The FS/DL time slot is transmitted on RDO and RSIG. During idle time slots no signaling information is transmitted. Data on RSIG are only valid if the freeze signaling status is inactive. With FMR2.SAIS all-ones data is transmitted on RDO and RSIG. Updating of the received signaling information is controlled by the freeze signaling status. The freeze signaling status is automatically activated if a loss-of-signal, or a lossof-frame-alignment or a receive slip occurs. The current freeze status is output on port FREEZE (RP(A:D)) and indicated by register SIS.SFS. If SIS.SFS is active updating of the registers RS(12:1) is disabled. Optionally automatic freeze signaling is disabled by setting bit SIC3.DAF. After CAS resynchronization an interrupt is generated. Because at this time the signaling is still frozen, CAS data is not valid yet. Readout of CAS data has to be delayed until the next CAS multiframe is received. 5.1.14.4 CAS Bit-Robbing (T1/J1, µP access mode) The signaling information is carried in the LSB of every sixth frame for each time slot. Receive data is stored in registers RS(12:1) aligned to the CAS multiframe boundary. To relieve the µP load from always reading the complete RS(12:1) buffer every 3 ms the FALC56 notifies the µP by interrupt ISR0.RSC only when signaling changes from one multiframe to the next. Additionally the FALC56 generates a receive signaling data change pointer (RSP1/2) which directly points to the updated RS(12:1) register. Because the CAS controller is working on the PCM highway side of the receive buffer, slips disturb the CAS data. 5.1.14.5 Bit Oriented Messages in ESF-DL Channel (T1/J1) The FALC56 HDLC channel 1 supports the DL-channel protocol for ESF format according to ANSI T1.403 specification or according to AT&T TR54016. The HDLC and bit oriented message (BOM) receiver are switched on/off independently. If the FALC56 is used for HDLC formats only, the BOM receiver has to be switched off. If HDLC and Data Sheet 137 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 BOM receiver have been switched on (MODE.HRAC/BRAC), an automatic switching between HDLC and BOM mode is enabled. If eight or more consecutive ones are detected, the BOM mode is entered. Upon detection of a flag in the data stream, the FALC56 switches back to HDLC mode. In BOM mode, the following byte format is assumed (the left most bit is received first): 111111110xxxxxx0 Three different BOM reception modes can be programmed (CCR1.BRM+ CCR2.RBFE). If CCR2.RFBE is set, the BOM receiver accepts only BOM frames after detecting 7 out of 10 equal BOM pattern. Buffering of receive data is done in a 64 byte deep RFIFO. 5.1.14.6 4 kbit/s Data Link Access in F72 Format (T1/J1) The DL-channel protocol is supported as follows: • access is done on a multiframe basis through registers RDL(3:1), • the DL-bit information from frame 26 to 72 is stored in the receive FIFO of the signaling controller. Data Sheet 138 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.2 Framer Operating Modes (T1/J1) 5.2.1 General Activated with bit FMR1.PMOD = 1. PCM line bit rate Single frame length Framing frequency Organization : : : : 1.544 Mbit/s 193 bit, No. 1…193 8 kHz 24 time slots, No. 1…24 with 8 bits each, No. 1…8 and one preceding F-bit Selection of one of the four permissible framing formats is performed by bits FMR4.FM1/ 0. These formats are: F4 F12 ESF F72 : : : : 4-frame multiframe 12-frame multiframe (D4) Extended Superframe (F24) 72-frame multiframe (SLC96) The operating mode of the FALC56 is selected by programming the carrier data rate and characteristics, line code, multiframe structure, and signaling scheme. The FALC56 implements all of the standard and/or common framing structures PCM24 (T1/J1, 1.544 Mbit/s) carriers. The internal HDLC controller supports all signaling procedures including signaling frame synchronization/synthesis in all framing formats. After reset, the FALC56 must be programmed with FMR1.PMOD = 1 to enable the T1/ J1 (PCM24) mode. Switching between the framing formats is done by bit FMR4.FM1⁄0 for the receiver and for the transmitter. 5.2.2 General Aspects of Synchronization Synchronization status is reported by bit FRS0.LFA (Loss Of Frame Alignment). Framing errors (pulse frame and multiframe) are counted by the Framing Error Counter FEC. Asynchronous state is reached if 2 out of 4 (bit FMR4.SSC1/0 = 00), or 2 out of 5 (bit FMR4.SSC1/0 = 01), or 2 out of 6 (bit FMR4.SSC1/0 = 10), or 4 consecutive multiframe pattern in ESF format are incorrect (bit FMR4.SSC1/0 = 11). If auto mode is enabled, counting of framing errors is interrupted. The resynchronization procedure is controlled by either one of the following procedures: • Automatically (FMR4.AUTO = 1). Additionally, it can be triggered by the user by setting/resetting one of the bits FMR0.FRS (force resynchronization) or FMR0.EXLS (external loss of frame). Data Sheet 139 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 • User controlled, exclusively, by the control bits described above in the non-auto mode (FMR4.AUTO = 0). 5.2.3 Addition for F12 and F72 Format FT and FS bit conditions, i.e. pulse frame alignment and multiframe alignment can be handled separately if programmed by bit FMR2.SSP. Thus, a multiframe resynchronization can be automatically initiated after detecting 2 errors out of 4/5/6 consecutive multiframing bits without influencing the state of the terminal framing. In the synchronous state, the setting of FMR0.FRS or FMR0.EXLS resets the synchronizer and initiates a new frame search. The synchronous state is reached if there is only one definite framing candidate. In the case of repeated apparent simulated candidates, the synchronizer remains in the asynchronous state. In asynchronous state, the function of FMR0.EXLS is the same as above. Setting bit FMR0.FRS induces the synchronizer to lock onto the next available framing candidate if there is one. Otherwise a new frame search is started. This is useful in case the framing pattern that defines the pulseframe position is imitated periodically by a pattern in one of the speech/data channels. The control bit FMR0.EXLS should be used first because it starts the synchronizer to search for a definite framing candidate. To observe actions of the synchronizer, the Frame Search Restart Flag FRS0.FSRF is implemented. It toggles at the start of a new frame search if no candidate has been found at previous attempt. When resynchronization is initiated, the following values apply for the time required to achieve the synchronous state in case there is one definite framing candidate within the data stream: Table 32 Resynchronization Timing (T1/J1) Frame Mode Average Maximum Units F4 F12 ESF F72 1.0 3.5 3.4 13.0 1.5 4.5 6.125 17.75 ms Data Sheet 140 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Auto-Mode Definite Candidate Non-Auto-Mode Definite Candidate DON Multiple Candidates EXLS, FRS EXLS, FRS FRS FRS DON DON Synchronous DOFF 1) DOFF EXLS EXLS FRS FRS : Depends on the Disturbance D : One Disturbance Asynchronous Multiple Candidates Asynchronous Synchronous EXLS, FRS 1) Data Sheet DON DOFF DOFF Figure 49 Asynchronous Synchronous Synchronous FRS EXLS, FRS Asynchronous EXLS ITD03574 Influences on Synchronization Status (T1/J1) 141 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Figure 49 gives an overview of influences on synchronization status for the case of different external actions. Activation of auto mode and non-auto mode is performed by bit FMR4.AUTO. Generally, for initiating resynchronization it is recommended to use bit: FMR0.EXLS first. In cases where the synchronizer remains in the asynchronous state, bit FMR0.FRS is used to enforce it to lock onto the next framing candidate, although it might be a simulated one. 5.2.4 4-Frame Multiframe (F4 Format, T1/J1) The allocation of the FT-bits (bit 1 of frames 1 and 3) for frame alignment signal is shown in Table 33. The FS-bit can be used for signaling. Remote alarm (yellow alarm) is indicated by setting bit 2 to 0 in each time slot. Table 33 4-Frame Multiframe Structure (T1/J1) Frame Number FT 1 2 3 4 1 – 0 – 5.2.4.1 FS service bit service bit Synchronization Procedure For multiframe synchronization, the terminal framing bits (FT-bits) are observed. The synchronous state is reached if at least one terminal framing candidate is definitely found, or the synchronizer is forced to lock onto the next available candidate (FMR0.FRS). Data Sheet 142 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.2.5 12-Frame Multiframe (D4 or SF Format, T1/J1) Normally, this kind of multiframe structure only makes sense when using the CAS robbed-bit signaling. The multiframe alignment signal is located at the FS-bit position of every other frame (refer to Table 34). Table 34 12-Frame Multiframe Structure (T1/J1) Frame Number FT FS 1 2 3 4 5 6 7 8 9 10 11 12 1 – 0 – 1 – 0 – 1 – 0 – – 0 – 0 – 1 – 1 – 1 – 0 Signaling Channel Designation A B There are two possibilities of remote alarm (yellow alarm) indication: • Bit 2 = 0 in each time slot of a frame, selected with bit FMR0.SRAF = 0 • The last bit of the multiframe alignment signal (bit 1 of frame 12) changes from "0" to "1", selected with bit FMR0.SRAF = 1. 5.2.5.1 Synchronization Procedure In the synchronous state terminal framing (FT-bits) and multiframing (FS-bits) are observed, independently. Further reaction on framing errors depends on the selected synchronization/resynchronization procedure (by bit FMR2.SSP): • FMR2.SSP = 0: terminal frame and multiframe synchronization are combined. Two errors within 4/5/6 framing bits (by bits FMR4.SSC1/0) of one of the above leads to the asynchronous state for terminal framing and multiframing. Additionally to the bit FRS0.LFA, loss of multiframe alignment is reported by bit FRS0.LMFA. The resynchronization procedure starts with synchronizing upon the terminal framing. If the pulse framing has been regained, the search for multiframe alignment is initiated. Multiframe synchronization has been regained after two consecutive correct multiframe patterns have been received. • FMR2.SSP = 1: terminal frame and multiframe synchronization are separated Two errors within 4/5/6 terminal framing bits lead to the same reaction as described Data Sheet 143 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 above for the “combined” mode. Two errors within 4/5/6 multiframing bits lead to the asynchronous state only for the multiframing. Loss of multiframe alignment is reported by bit FRS0.LMFA. The state of terminal framing is not influenced. Now, the resynchronization procedure includes only the search for multiframe alignment. Multiframe synchronization has been regained after two consecutive correct multiframe patterns have been received. 5.2.6 Extended Superframe (F24 or ESF Format, T1/J1) The use of the first bit of each frame for the multiframe alignment word, the data link bits, and the CRC bits is shown in Table 35 on page 144. Table 35 Extended Superframe Structure (F24, ESF; T1/J1) Multiframe Frame Number Multiframe Bit Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Data Sheet 0 193 386 579 772 965 1158 1351 1544 1737 1930 2123 2316 2509 2702 2895 3088 3231 3474 3667 3860 4053 4246 4439 F-Bits Assignments FAS DL CRC – – – 0 – – – 0 – – – 1 – – – 0 – – – 1 – – – 1 m – m – m – m – m – m – m – m – m – m – m – m – – e1 – – – e2 – – – e3 – – – e4 – – – e5 – – – e6 – – 144 Signaling Channel Designation A B C D 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.2.6.1 Synchronization Procedures For multiframe synchronization the FAS-bits are observed. Synchronous state is reached if at least one framing candidate is definitely found, or the synchronizer is forced to lock onto the next available candidate (FMR0.FRS). In the synchronous state the framing bits (FAS-bits) are observed. The following conditions selected by FMR4.SSC1/0 lead to the asynchronous state: • • • • two errors within 4/5/6 framing bits two or more erroneous framing bits within one ESF multiframe more than 320 CRC6 errors per second interval (FMR5.SSC2) 4 incorrect (1 out of 6) consecutive multiframes independent of CRC6 errors. There are four multiframe synchronization modes selectable using FMR2.MCSP and FMR2.SSP. • FMR2.MCSP/SSP = 00: In the synchronous state, the setting of FMR0.FRS or FMR0.EXLS resets the synchronizer and initiates a new frame search. The synchronous state is reached again, if there is only one definite framing candidate. In the case of repeated apparent simulated candidates, the synchronizer remains in the asynchronous state. In asynchronous state, setting bit FMR0.FRS induces the synchronizer to lock onto the next available framing candidate if there is one. At the same time the internal framing pattern memory is cleared and other possible framing candidates are lost. • FMR2.MCSP/SSP = 01: Synchronization is achieved when 3 consecutive multiframe pattern are correctly found independent of the occurrence of CRC6 errors. If only one or two consecutive multiframe pattern were detected the FALC56 stays in the asynchronous state, searching for a possible additionally available framing pattern. This procedure is repeated until the framer has found three consecutive multiframe pattern in a row. • FMR2.MCSP/SSP = 10: This mode has been added in order to be able to choose multiple framing pattern candidates step by step. I.e. if in synchronous state the CRC error counter indicates that the synchronization might have been based on an alias framing pattern, setting of FMR0.FRS leads to synchronization on the next candidate available. However, only the previously assumed candidate is discarded in the internal framing pattern memory. The latter procedure can be repeated until the framer has locked on the right pattern (no extensive CRC errors). The synchronizer is reset completely and initiates a new frame search, if there is no multiframing found. In this case bit FRS0.FSRF toggles. • FMR2.MCSP/SSP = 11: Synchronization including automatic CRC6 checking Synchronization is achieved when framing pattern are correctly found and the CRC6 checksum is received without an error. If the CRC6 check failed on the assumed Data Sheet 145 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 framing pattern the FALC56 stays in the asynchronous state, searching for a possible available framing pattern. This procedure is repeated until the framer has locked on the right pattern. This automatic synchronization mode has been added in order to reduce the microprocessor load. 5.2.6.2 Remote Alarm (yellow alarm) Generation/Detection Remote alarm (yellow alarm) is indicated by the periodical pattern "1111 1111 0000 0000 …" in the DL-bits (T1 mode, RC0.SJR = 0). Remote alarm is declared even in the presence of a bit error rate of up to 10-3. The alarm is reset when the yellow alarm pattern no longer is detected. Depending on bit RC0.SJR = 1 the FALC56 generates and detects the remote alarm according to JT G. 704. In the DL-bit position 16 continuous "1" are transmitted if FMR0.SRAF = 0 and FMR4.XRA = 1. 5.2.6.3 CRC6 Generation and Checking (T1/J1) Generation and checking of CRC6 bits transmitted/received in the E(6:1) bit positions is done according to ITU-T G.706. The CRC6 checking algorithm is enabled by bit FMR1.CRC. If not enabled, all check bits in the transmit direction are set. In the synchronous state received CRC6 errors are accumulated in a 16 bit error counter and are additionally indicated by an interrupt status. • CRC6 inversion If enabled by bit RC0.CRCI, all CRC bits of one outgoing extended multiframe are automatically inverted in case a CRC error is flagged for the previous received multiframe. Setting the bit RC0.XCRCI inverts the CRC bits before transmitted to the distant end. This function is logically ored with RC0.CRCI. • CRC6 generation/checking according to JT G.706 Setting of RC0.SJR the FALC56 generates and checks the CRC6 bits according to JT G.706. The CRC6 checksum is calculated including the FS/DL-bits. In synchronous state CRC6 errors increment an error counter. 5.2.7 72-Frame Multiframe (SLC96 Format, T1/J1) The 72-multiframe is an alternate use of the FS-bit pattern and is used for carrying data link information. This is done by stealing some of redundant multiframing bits after the transmission of the 12-bit framing header (refer to Figure 36 on page 148). The position of A and B signaling channels (robbed bit signaling) is defined by zero-to-one and oneto-zero transitions of the FS-bits and is continued when the FS-bits are replaced by the data link bits. Data Sheet 146 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Remote alarm (yellow alarm) is indicated by setting bit 2 to zero in each time slot. An additional use of the D-bits for alarm indication is user defined and must be done externally. 5.2.7.1 Synchronization Procedure In the synchronous state terminal framing (FT-bits) and multiframing (FS-bits of the framing header) are observed independently. Further reaction on framing errors depends on the selected synchronization/resynchronization procedure (by bit FMR2.SSP): • FMR2.SSP = 0: terminal frame and multiframe synchronization are combined Two errors within 4/5/6 framing bits (by bits FMR4.SSC1/0) of one of the above lead to the asynchronous state for terminal framing and multiframing. Additionally to The resynchronization procedure starts with synchronizing upon the terminal framing. If the pulse framing has been regained, the search for multiframe alignment is initiated. Multiframe synchronization has been regained after two consecutive correct multiframe patterns have been received. • FMR2.SSP = 1: terminal frame and multiframe synchronization are separated Two errors within 4/5/6 terminal framing bits lead to the same reaction as described above for the “combined” mode. Two errors within 4/5/6 multiframing bits lead to the asynchronous state only for the multiframing. Loss of multiframe alignment is reported by bit FRS0.LMFA. The state of terminal framing is not influenced. Now, the resynchronization procedure includes only the search for multiframe alignment. Multiframe synchronization has been regained after two consecutive correct multiframe patterns have been received. Data Sheet 147 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Table 36 72-Frame Multiframe Structure (T1/J1) Frame Number FT FS 1 2 3 4 5 6 7 8 9 10 11 12 1 – 0 – 1 – 0 – 1 – 0 – – 0 – 0 – 1 – 1 – 1 – 0 13 14 15 16 17 18 19 20 21 22 23 24 1 – 0 – 1 – 0 – 1 – 0 – – 0 – 0 – 1 – 1 – 1 – D 25 26 27 28 · 66 67 68 69 70 71 72 1 – · · 1 – 0 – 1 – 0 – – D · · – D – D – D – 0 Data Sheet 148 Signaling Channel Designation A B A B A B 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.2.8 Summary of Frame Conditions (T1/J1) Table 37 Summary Frame Recover/Out of Frame Conditions (T1/J1) Format Frame Recover Condition F4 only one FT pattern found, optional 2 out of 4/5/6 incorrect FT-bits forcing on next available FT framing candidate F12 (D4) FMR2.SSP = 0: Combined FT + FS framing search: First searching for FT pattern with optional forcing on next available framing candidates and then for 2 consecutive correct FS pattern1). FMR2.SSP = 1: Separated FT + FS pattern search: Loss of FT framing starts first search for FT and then for 2 consecutive correct FS pattern1). Loss of FS framing starts only the FS pattern1) search. FMR2.SSP = 0: 2 out of 4/5/6 incorrect FT- or FS-bits FMR2.SSP = 1: 2 out of 4/5/6 incorrect FT-bits searched in FT and FS framing bits, 2 out of 4/5/6 incorrect FS-bits searched only the FS framing. FMR2.MCSP/SSP = 00: only one FAS pattern found, optional forcing on next available FAS framing candidate with discarding of all remaining framing candidates. FMR2.MCSP/SSP = 01: 3 consecutive correct multiframing found independent of CRC6 errors. FMR2.MCSP/SSP = 10: choosing multiple framing pattern step by step, optional forcing on next available FAS framing pattern with discarding only of the previous assumed framing candidate. FMR2.MCSP/SSP = 11: FAS framing correctly found and CRC6 check error free. 2 out of 4/5 incorrect FAS-bits or 2 out of 6 incorrect FAS-bits per multiframe or 4 consecutive incorrect multiframing pattern or more than 320 CRC6 errors per second interval and F72 (SLC96) F24 (ESF) 1) Out of Frame Condition In F12 (D4) format bit 1 in frame 12 is excluded from the synchronization process. Data Sheet 149 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.3 Additional Receive Framer Functions (T1/J1) 5.3.1 Error Performance Monitoring and Alarm Handling • Alarm Indication Signal: Detection and recovery is flagged by bit FRS0.AIS and ISR2.AIS. Transmission is enabled by bit FMR1.XAIS. • Loss-Of-Signal: Detection and recovery is flagged by bit FRS0.LOS and ISR2.LOS. • Remote Alarm Indication: Detection and release is flagged by bit FRS0.RRA and ISR2.RA/RAR. Transmission is enabled by bit FMR4.XRA. • Excessive Zeros: Detection is flagged by bit FRS1.EXZD. • Pulse-Density Violation: Detection is flagged by bit FRS1.PDEN and ISR0.PDEN. • Transmit Line Shorted: Detection and release is flagged by bit FRS1.XLS and ISR1.XLSC. • Transmit Ones-Density: Detection and release is flagged by bit FRS1.XLO and ISR1.XLSC. Table 38 Summary of Alarm Detection and Release (T1/J1) Alarm Detection Condition Clear Condition Red Alarm or Loss-Of-Signal (LOS) no transitions (logical zeros) in a programmable time interval of 16 to 4096 consecutive pulse periods. Programmable receive input signal threshold programmable number of ones (1 to 256) in a programmable time interval of 16 to 4096 consecutive pulse periods. A one is a signal with a level above the programmed threshold. or the pulse-density is fulfilled and no more than 15 contiguous zeros during the recovery interval are detected. Blue Alarm or Alarm Indication Signal (AIS) active for at least one multiframe. FMR4.AIS3 = 0: less than 3 zeros in 12 frames or FMR4.AIS3 = 0: 24 frames (ESF), more than 2 zeros in 12 or 24 frames (ESF), FMR4.AIS3 = 1: less than 4 zeros in 12 frames or less than 6 zeros in 24 frames (ESF) Data Sheet 150 FMR4.AIS3 = 1: more than 3 zeros in 12 frames or more than 5 zeros in 24 frames (ESF) 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Table 38 Summary of Alarm Detection and Release (T1/J1) (cont’d) Alarm Detection Condition Clear Condition Yellow Alarm or Remote Alarm (RRA)1) RC1.RRAM = 0: bit 2 = 0 in 255 consecutive time slots or FS-bit = 1 of frame12 in F12 (D4) format or 8×1,8×0 in the DL channel (ESF) RC1.RRAM = 1: bit 2 = 0 in every time slot per frame or FS-bit = 1 of frame12 in F12 (D4) format or 8×1,8×0 in the DL channel (ESF) RC1.RRAM = 0: set conditions no longer detected. Excessive Zeros (EXZD) more than 7 (B8ZS code) or more than 15 (AMI code) contiguous zeros Latched Status: cleared on read Pulse-Density Violation (PDEN) less than N ones in each and Latched Status: cleared on read every time window of 8×(N+1) time slots with N taking all values of 1 to 23 or more than 15 consecutive zeros Transmit Line Short (XLS) more than 3 pulse periods with highly increased transmit line current on XL1/2 transmit line current limiter inactive Transmit OnesDensity (XLO) 32 consecutive zeros in the transmit data stream on XL1/2 Cleared with each transmitted pulse 1) RC1.RRAM = 1: bit 2 = 0 not detected in 3 consecutive frames or FS-bit not detected in 3 consecutive multiframes or 8×1,8×0 not detected for 3 times in a row (ESF). RRA detection operates in the presence of 10-3 bit error rate. 5.3.2 Auto Modes • Automatic remote alarm (Yellow Alarm) access If the receiver has lost its synchronization (FRS0.LFA) a remote alarm (yellow alarm) is sent to the distant end automatically, if enabled by bit FMR2.AXRA. In synchronous state the remote alarm bit is removed. • Automatic AIS to system interface In asynchronous state the synchronizer enforces an AIS to the receive system interface automatically. However, received data is switched through transparently if bit FMR2.DAIS is set. Data Sheet 151 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 • Automatic clock source switching In slave mode (LIM0.MAS = 0) the DCO-R synchronizes on the recovered route clock. In case of loss-of-signal (LOS) the DCO-R switches to master mode automatically. If bit CMR1.DCS is set, automatic switching from RCLK to SYNC is disabled. • Automatic freeze signaling: Updating of the received signaling information is controlled by the freeze signaling status. The freeze signaling status is activated automatically, if a loss-of-signal or a loss of multiframe alignment or a receive slip occurs. The internal signaling buffer RS(12:1) is frozen. Optionally automatic freeze signaling is disabled by setting bit SIC3.DAF = 1. 5.3.3 Error Counter The FALC56 offers six error counters where each of them has a length of 16 bit. They record code violations, framing bit errors, CRC6 bit errors, errored blocks and the number of received multiframes in asynchronous state or the changes of frame alignment (COFA). Counting of the multiframes in asynchronous state and of the COFA parameter is done in a 6/2-bit counter. Each of the error counters is buffered. Buffer update is done in two modes: • One-second accumulation • On demand using handshake with writing to the DEC register. In the one-second mode an internal/external one-second timer updates these buffers and resets the counter to accumulate the error events in the next one-second period. The error counter cannot overflow. Error events occurring during error counter reset are not be lost. 5.3.4 Errored Second The FALC56 supports the error performance monitoring by detecting the following alarms or error events in the received data: framing errors, CRC errors, code violations, loss of frame alignment, loss-of-signal, alarm indication signal, receive and transmit slips. With a programmable interrupt mask register ESM all these alarms or error events can generate an Errored Second Interrupt (ISR3.ES) if enabled. 5.3.5 One-Second Timer Additionally a one-second timer interrupt can be generated internally to indicate that the enabled alarm status bits or the error counters have to be checked. The one-second timer signal is output on port SEC/FSC (GPC1.CSFP1/0). Optionally synchronization to an external second timer is possible which has to be provided on pin SEC/FSC. Selecting the external second timer is done with GCR.SES. Refer also to register GPC1 for input/output selection. Data Sheet 152 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.3.6 Clear Channel Capability For support of common T1 applications, clear channels can be specified through the 3byte register bank CCB(1:3). In this mode the contents of selected transmit time slots are not overwritten by internally or externally sourced bit-robbing and zero code suppression (B7 stuffing) information. 5.3.7 In-Band Loop Generation and Detection The FALC56 generates and detects a framed or unframed in-band loop-up (activate, 00001) and loop-down (deactivate, 001) pattern according to ANSI T1.403 with bit error rates as high as 10-2. Framed or unframed in-band loop code is selected by LCR1.FLLB. Replacing the in-band loop codes with transmit data is done by FMR5.XLD/XLU. The FALC56 also offers the ability generating and detecting of a flexible in-band loop-up and -down pattern (LCR1.LLBP = 1). The loop-up and loop-down pattern is individually programmable from 2 to 8 bits in length (LCR1.LAC1/0 and LCR1.LDC1/0). Programming of loop codes is done in registers LCR2 and LCR3. Status and interrupt status bits inform the user whether loop-up or loop-down code was detected. 5.3.8 Transparent Mode The transparent modes are useful for loop-backs or for routing data unchanged through the FALC56. In receive direction, transparency for ternary or dual-/single-rail unipolar data is always achieved if the receiver is in the synchronous state. All bits in F-bit position of the incoming multiframe are forwarded to RDO and inserted in the FS/DL time slot or in the F-bit position. In asynchronous state the received data is switched through transparently if bit FMR2.DAIS is set. Setting of bit LOOP.RTM disconnects control of the elastic buffer from the receiver. The elastic buffer is now in a “free running” mode without any possibility to update the time slot assignment to a new frame position in case of resynchronization of the receiver. Together with FMR2.DAIS this function is used to realize undisturbed transparent reception. Setting bit FMR4.TM switches the FALC56 in transmit transparent mode: In transmit direction bit 8 of the FS/DL time slot from the system highway (XDI) is inserted in the F-bit position of the outgoing frame. For complete transparency the internal signaling controller, idle code generation, AIS alarm generation, single channel and payload loop-back has to be disabled and cleared channels have to be defined by registers CCB1…3. 5.3.9 Pulse-Density Detection The FALC56 examines the receive data stream on the pulse-density requirement which is defined by ANSI T1. 403. More than 14 consecutive zeros or less than N ones in each Data Sheet 153 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 and every time window of 8×(N+1) data bits where N = 23 are detected. Violations of these rules are indicated by setting the status bit FRS1.PDEN and the interrupt status bit ISR0.PDEN. Generation of the interrupt status is programmed either with the detection or with any change of state of the pulse-density alarm (GCR.SCI). 5.4 Transmit Path in T1/J1 Mode 5.4.1 Transmitter (T1/J1) The serial bit stream is then processed by the transmitter which has the following functions: • • • • • • Frame/multiframe synthesis of one of the four selectable framing formats Insertion of service and data link information AIS generation (blue alarm) Remote alarm (yellow alarm) generation CRC generation and insertion of CRC bits CRC bits inversion in case of a previously received CRC error or in case of activating per control bit • Generation of loop-up/-down code • Idle code generation per DS0 The frame/multiframe boundaries of the transmitter can be synchronized externally by using the SYPX/XMFS pin. Any change of the transmit time slot assignment subsequently produces a change of the framing bit positions on the line side. This feature is required if signaling and data link bits are routed through the switching network and are inserted in transmit direction by the system interface. In loop-timed configuration (LIM2.ELT) disconnecting the control of the transmit system highway from the transmitter is done by setting FMR5.XTM. The transmitter is now in a free running mode without any possibility to update the multiframe position in case of changing the transmit time slot assignment. The FS/DL-bits are generated independent of the transmit system interface. For proper operation the transmit elastic buffer size should be programmed to 2 frames. The contents of selectable time slots is overwritten by the pattern defined by register IDLE. The selection of “idle channels” is done by programming the three-byte registers ICB(3:1). If AMI coding with zero code suppression (B7-stuffing) is selected, “clear channels” without B7-stuffing can be defined by programming registers CCB(3:1). 5.4.2 Transmit Line Interface (T1/J1) The analog transmitter transforms the unipolar bit stream to ternary (alternate bipolar) return to zero signals of the appropriate programmable shape. The unipolar data is provided on pin XDI and the digital transmitter. Data Sheet 154 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Similar to the receive line interface three different data types are supported: R1 XL1 Line t1 t2 FALC R R1 XL2 ITS10968 Figure 50 Transmitter Configuration (T1/J1) Table 39 Recommended Transmitter Configuration Values (T1/J1) Parameter T1 J1 Characteristic Impedance [Ω] 100 110 R1 (± 1%) [Ω] 21) t2 : t1 1) 1 : 2.4 This value refers to an ideal transformer without any parasitics. Any transformer resistance or other parasitic resistances have to be taken into account when calculating the final value of the output serial resistors. • Ternary Signal Single-rail data is converted into a ternary signal which is output on pins XL1 and XL2. Selection between B8ZS or simple AMI coding with zero code suppression (B7 stuffing) is provided. B7 stuffing can be disabled on a per time slot basis (Clear Channel capability). Selected by FMR0.XC1/0 and LIM1.DRS = 0. • Dual-rail data PCM(+), PCM(-) at multifunction ports XDOP and XDON with 50% or 100% duty cycle and with programmable polarity. Line coding is done in the same way as in ternary interface mode. Selected by FMR0.XC1 = 1 and LIM1.DRS = 1. • Unipolar data on port XOID is transmitted in NRZ (non return to zero) with 100% duty cycle or in CMI code with or without (SIC3.CMI) preprocessed by B8ZS coding to a fiber-optical interface. Clocking off data is done with the rising edge of the transmit clock XCLK (1544 kHz) and with a programmable polarity. Selection is done by FMR0.XC1 = 0 and LIM1.DRS = 1. 5.4.3 Transmit Jitter Attenuator (T1/J1) The transmit jitter attenuator DCO-X circuitry generates a "jitter-free" transmit clock and meets the following requirements: PUB 62411, PUB 43802, TR-TSY 009,TR-TSY 253, TR-TSY 499 and ITU-T I.431 and G.703. The DCO-X circuitry works internally with the Data Sheet 155 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 same high frequency clock as the receive jitter attenuator. It synchronizes either to the working clock of the transmit backplane interface or the clock provided on pin TCLK or the receive clock RCLK (remote loop/loop-timed). The DCO-X attenuates the incoming jitter starting at 6 Hz with 20 dB per decade fall-off. With the jitter attenuated clock, which is directly depending on the phase difference of the incoming clock and the jitter attenuated clock, data is read from the transmit elastic buffer (2 frames) or from the JATT buffer (2 frames, remote loop). Wander with a jitter frequency below 6 Hz is passed transparently. The DCO-X accepts gapped clocks which are used in ATM or SDH/SONET applications. The jitter attenuated clock is output on pin XCLK or optionally on pin CLK2. In case of missing clock on pin SCLKX the DCO-X centers automatically, if selected by bit CMR2.DCOXC = 1. The transmit jitter attenuator can be disabled. In that case data is read from the transmit elastic buffer with the clock sourced on pin TCLK (1.544 or 6.176 MHz). Synchronization between SCLKX and TCLK has to be done externally. In the loop-timed clock configuration (LIM2.ELT) the DCO-X circuitry generates a transmit clock which is frequency synchronized on RCLK. In this configuration the transmit elastic buffer has to be enabled. RCLK RL1/2 RDIP/N ROID Equalizer DPLL Line Decoder Receive Data Line Encoder Transmit Data DRS JATT Buffer Line Driver Pulse Shaper ~ ~ XL1/2 DRS XDOP/N XOID RCLK RCLK Transmit Jitter Attenuator Clock Unit MCLK ITS10299 Figure 51 Data Sheet Clocking in Remote Loop Configuration (T1/J1) 156 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 XL1/ XDOP/ XOID XL2/ XDON DR D DR Framer A Transmit Elastic Store XDI Pulse Shaper XCLK TCLK (E1: 8MHz) (T1: 6MHz) SCLKR ÷4 E1: 8MHz T1: 6MHz DCO-X Transmit Jitter Attenuator MCLK Figure 52 Clocking Unit Internal Clock of Receive System Interface SCLKX TCLK RCLK ITS10305 Transmit Clock System (T1/J1) Note: DR = Dual-Rail interface DCO-X Digital Controlled Oscillator transmit 5.4.4 Transmit Elastic Buffer (T1/J1) The transmit elastic store with a size of max. 2 × 193 bit (two frames) serves as a temporary store for the PCM data to adapt the system clock (SCLKX) to the internally generated clock for the transmit data, and to retranslate time slot structure used in the system to that of the line side. Its optimal start position is initiated when programming the transmit time slot offset values. A difference in the effective data rates of system side and transmit side lead to an overflow or underflow of the transmit memory. Thus, errors in data transmission to the remote end occur. This error condition (transmit slip) is reported to the microprocessor by interrupt status registers. The received bit stream from pin XDI is optionally stored in the transmit elastic buffer. The memory is organized as the receive elastic buffer. Programming of the transmit buffer size is done by SIC1.XBS1/0: • XBS1/0 = 00: bypass of the transmit elastic buffer • XBS1/0 = 01: one frame buffer or 193 bits Maximum of wander amplitude (peak-to-peak): (1 UI = 648 ns) System interface clocking rate: modulo 2.048 MHz: Data Sheet 157 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Maximum of wander: 70 UI in channel translation mode 0 Maximum of wander: 45 UI in channel translation mode 1 System interface clocking rate: modulo 1.544 MHz: Maximum of wander: 74 UI average delay after performing a slip: 96 bits • XBS1/0 = 10: two frame buffer or 386 bits System interface clocking rate: modulo 2.048 MHz: 142 UI in channel translation mode 0 78 UI in channel translation mode 1 System interface clocking rate: modulo 1.544 MHz: Maximum of wander: 140 UI average delay after performing a slip: 193 bits • XBS1/0 = 11: short buffer or 96 bits: System interface clocking rate: modulo 2.048 MHz: Maximum of wander: 28 UI in channel translation mode 0; channel translation mode 1 not supported System interface clocking rate: modulo 1.544 MHz: Maximum of wander: 38 UI average delay after performing a slip: 48 bits The functions of the transmit buffer are: • Clock adaption between system clock (SCLKX/R) and internally generated transmit route clock (XCLK) or externally sourced TCLK. • Compensation of input wander and jitter. • Frame alignment between system frame and transmit route frame • Reporting and controlling of slips Writing of received data from XDI is controlled by SCLKX/R and SYPX/XMFS in combination with the programmed offset values for the transmit time slot/clock slot counters. Reading of stored data is controlled by the clock generated by DCO-X circuitry or the externally generated TCLK and the transmit framer. With the de-jittered clock data is read from the transmit elastic buffer and are forwarded to the transmitter. Reporting and controlling of slips is automatically done according to the receive direction. Positive/ negative slips are reported in interrupt status bits ISR4.XSP and ISR4.XSN. A reinitialization of the transmit memory is done by reprogramming the transmit time slot counter XC1 and with the next SYPX pulse. After that, this memory has its optimal start position. The frequency of the working clock for the transmit system interface is programmable by SIC1.SSC1/0 and SIC2.SSC2 in a range of 1.544 to 12.352 MHz/2.048 to 16.384 MHz. Generally the data or marker on the system interface are clocked off or latched on the rising or falling edge (SIC3.RESX) of the SCLKX clock. Some clocking rates allow transmission of time slots/marker in different channel phases. Each channel phase Data Sheet 158 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 which shall be latched on ports XDI and XP(A:D) is programmable by bits SIC2.SICS(2:0), the remaining channel phases are cleared or ignored respectively. The following table gives an overview of the transmit buffer operating modes. Table 40 Transmit Buffer Operating Modes (T1/J1) Buffer Size TS Offset programming Slip performance bypass enabled no short buffer disabled yes 1 frame enabled yes 2 frames enabled yes 5.4.5 Programmable Pulse Shaper and Line Build-Out (T1/J1) In long-haul applications the transmit pulse masks are optionally generated according to FCC68 and ANSI T1. 403. To reduce the crosstalk on the received signals the FALC56 offers the ability to place a transmit attenuator in the data path. Transmit attenuation is selectable from 0, -7.5, -15 or -22.5 dB (register LIM2.LBO2/1). ANSI T1. 403 defines only 0 to -15 dB. The FALC56 includes a programmable pulse shaper to satisfy the requirements of ANSI T1. 102, also various DS1, DSX-1 specifications are met. The amplitude of the pulse shaper is individually programmable by the microprocessor to allow a maximum of different pulse templates. The line length is selected by programming the registers XPM(2:0) as shown for typical values in the table below. The values are optimized for transformer ratio: 1:2.4; cable: PULP 22AWG (100 Ω); serial resistors: 2 Ω. Table 41 Range in m Pulse Shaper Programming (T1/J1) Range in ft. XPM0 XPM1 XPM2 XP04- XP14XP00 XP10 hexadecimal XP24XP20 XP34XP30 decimal 0 to 40 0 to 133 D7 22 1 23 22 8 2 40 to 81 133 to 266 FA 26 1 26 23 9 2 81 to 122 266 to 399 3D 37 1 29 25 13 2 122 to 162 399 to 533 5F 3F 1 31 26 15 2 162 to 200 533 to 655 3F CB 1 31 25 18 3 The transmitter requires an external step up transformer to drive the line. Data Sheet 159 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.4.6 Transmit Line Monitor (T1/J1) The transmit line monitor compares the transmit line current on XL1 and XL2 with an onchip transmit line current limiter. The monitor detects faults on the primary side of the transformer indicated by a highly increased transmit line current (more than 120 mA for at least 3 consecutive pulses sourced by VDDX1)) and protects the device from damage by setting the transmit line driver XL1/2 into high-impedance state automatically (if enabled by XPM2.DAXLT = 0). The current limiter checks the actual current value of XL1/2 and if the transmit line current drops below the detection limit the high-impedance state is cleared. Two conditions are detected by the monitor: transmit line de-jitteredity (more than 31 consecutive zeros) indicated by FRS1.XLO and transmit line high current indicated by FRS1.XLS. In both cases a transmit line monitor status change interrupt is provided. Line Monitor TRI XL1 Pulse Shaper XL2 XDATA ITS10936 Figure 53 5.4.7 Transmit Line Monitor Configuration (T1/J1) Transmit Signaling Controller (T1/J1) Similar to the receive signaling controller the same signaling methods and the same time slot assignment are provided. The FALC56 performs the following signaling and data link methods. 5.4.7.1 HDLC or LAPD access The transmit signaling controller of the FALC56 performs the flag generation, CRC generation, zero bit stuffing and programmable idle code generation. Buffering of transmit data is done in the 64 byte deep XFIFO. The signaling information is internally multiplexed with the data applied to port XDI or XSIG. In signaling controller transparent mode, fully transparent data transmission without 1) shorts between XL1 or XL2 and VDDX are not detected Data Sheet 160 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 HDLC framing is performed. Optionally the FALC56 supports the continuous transmission of the XFIFO contents. Operating in HDLC or BOM mode “flags” or “idle” are transmitted as interframe timefill. The FALC56 offers the flexibility to insert data during certain time slots. Any combinations of time slots can be programmed separately for the receive and transmit direction if using HDLC channel 1. HDLC channel 2 and 3 support one programmable time slot common for receive and transmit direction each. 5.4.7.2 Support of Signaling System #7 The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is described in ITU-Q.703. The following description assumes, that the reader is familiar with the SS7 protocol definition. SS7 support must be activated by setting the MODE register. Data stored in the transmit FIFO (XFIFO) is sent automatically. The SS7 protocol is supported by the following hardware features in transmit direction: • transmission of flags at the beginning of each Signaling Unit • bit stuffing (zero insertion) • calculation of the CRC16 checksum: The transmitter adds the checksum to each Signaling Unit. Each signaling unit written to the transmit FIFO (XFIFO, 2×32 bytes) is sent once or repeatedly including flags, CRC checksum and stuffed bits. After e.g. an MSU has been transmitted completely, the FALC56 optionally starts sending of FISUs containing the forward sequence number (FSN) and the backward sequence number (BSN) of the previously transmitted signaling unit. Setting bit CCR5.AFX causes Fill In Signaling Units (FISUs) to be sent continuously, if no HDLC or Signaling Unit (SU) is to be transmitted from XFIFO. During update of XFIFO, automatic transmission is interrupted and resumed after update is completed. The internally generated FISUs contain FSN and BSN of the last transmitted signaling unit written to XFIFO. Using CMDR.XREP = 1, the contents of XFIFO can be sent continuously. Clearing of CMDR.XRES/SRES stops the automatic repetition of transmission. This function is also available for HDLC frames, so no flag generation, CRC byte generation and bit stuffing is necessary. Example: After an MSU has been sent repetitively and XREP has been cleared, FISUs are sent automatically. 5.4.7.3 CAS Bit-Robbing (T1/J1, serial mode) The signaling controller inserts the bit stream either on the transmit line side or if external signaling is enabled on the transmit system side. Signaling data is sourced on port XSIG, which is selected by register PC(4:1) and FMR5.EIBR = 1. Data Sheet 161 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 In external signaling mode the signaling data is sampled with the working clock of the transmit system interface (SCLKX) together with the transmit synchronous pulse (SYPX). Data on XSIG is latched in the bit positions 5 to 8 per time slot, bits 1 to 4 are ignored. The FS/DL-bit is sampled on port XSIG and inserted in the outgoing data stream. The received CAS multiframe is inserted frame aligned into the data stream on XDI. Data sourced by the internal signaling controller overwrites the external signaling data which must be valid during the last frame of a multiframe. Internal multiplexing of data and signaling data can be disabled on a per time slot basis (clear channel capability). This is also valid when using the internal and external signaling mode. 5.4.7.4 CAS Bit-Robbing (T1/J1, µP access mode) The signaling controller inserts the bit stream either on the transmit line side or if external signaling is enabled on the transmit system side. Signaling data is sourced internally from registers XS(12:1). Internal multiplexing of data and signaling data can be disabled on a per time slot basis (clear channel capability). This is also valid when using the internal and external signaling mode. 5.4.7.5 Data Link Access in ESF/F24 and F72 Format (T1/J1) The DL-channel protocol is supported as follows: • access is done on a multiframe basis through registers XDL(3:1) or • HDLC access or transparent transmission (non HDLC mode) from XFIFO (HDLC channel 1 only) The signaling information stored in the XFIFO is inserted in the DL-bits of frame 26 to 72 in F72 format or in every other frame in ESF format. Transmission can be done on a multiframe boundary (CCR1.XMFA = 1). Operating in HDLC or BOM mode “flags” or “idle” are transmitted as interframe timefill. 5.4.7.6 Periodical Performance Report in ESF Format (T1/J1) According to ANSI T1.403 the FALC56 can automatically generate the Periodical Performance Report (PPR) and transmit it every second in the data link channel of the extended superframe format (ESF/F24 only). Automatic sending of this report can be enabled/disabled by the use of bit CCR5.EPR. A single report can be initiated manually at any time (by setting CMDR2.XPPR = 1). Performance information is sampled every second and the report contains data of the last four seconds as shown in the following tables. Data Sheet 162 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 . Table 42 Structure of Periodical Performance Report (T1/J1)1) Octet No. 8 7 6 5 4 3 2 1 1 FLAG = 01111110 2 SAPI = 001110 CR2) EA=0 3 TEI = 0000000 4 CONTROL = 00000011 = unacklowledged frame EA=1 5 G3 LV G4 U1 U2 G5 SL G6 6 FE SE LB G1 R G2 Nm N1 7 G3 LV G4 U1 U2 G5 SL G6 8 FE SE LB G1 R G2 Nm N1 9 G3 LV G4 U1 U2 G5 SL G6 10 FE SE LB G1 R G2 Nm N1 11 G3 LV G4 U1 U2 G5 SL G6 12 FE SE LB G1 R G2 Nm N1 13 FCS 14 FCS 15 FLAG = time t0 t0-1 s t0-2 s t0-3 s 01111110 1) The rightmost bit (bit 1) is transmitted first for all fields except for the two bytes of the FCS that are transmitted leftmost bit (bit 8) first. 2) reflects state of bit CCR5.CR Data Sheet 163 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Table 43 Bit Functions in Periodical Performance Report1) Bit Value Interpretation G1 = 1 number of CRC error events = 1 G2 = 1 1 < number of CRC error events ≤ 5 G3 = 1 5 < number of CRC error events ≤ 10 G4 = 1 10 < number of CRC error events ≤ 100 G5 = 1 100 < number of CRC error events ≤ 319 G6 = 1 number of CRC error events ≥ 320 SE = 1 Severely errored framing event ≥ 1 (FE shall be 0) FE = 1 Frame synchronization bit error event ≥ 1 (SE shall be 0) LV = 1 Line code violation event ≥ 1 SL = 1 Slip event ≥ 1 LB = 1 Payload loop-back activated U1 not used (default value = 0) U2 not used (default value = 0) R not used (default value = 0) NmNi One-second report modulo 4 counter 1) according to ANSI T1.403 Data Sheet 164 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.5 System Interface in T1/J1 Mode The FALC56 offers a flexible feature for system designers where for transmit and receive direction different system clocks and system pulses are necessary. The interface to the receive system highway is realized by two data buses, one for the data RDO and one for the signaling data RSIG. The receive highway is clocked on pin SCLKR, while the interface to the transmit system highway is independently clocked on pin SCLKX. The frequency of these working clocks and the data rate of 2.048/4.096/8.192/16.384/1.544/ 3.088/6.192/12.352 Mbit/s for the receive and transmit system interface is programmable by SIC1.SSC1/0, SIC2.SSC2 and SIC1.SSD1, FMR1.SSD0. Selectable system clock and data rates and their valid combinations are shown in the table below. Table 44 System Clocking and Data Rates (T1/J1) System Data Rate Clock Rate 1.544/2.048 MHz Clock Rate 3.088/4.096 MHz Clock Rate 6.176/8.192 MHz Clock Rate 12.352/ 16.384 MHz 1.544/2.048 Mbit/s x x x x 3.088/4.096 Mbit/s -- x x x 6.176/8.192 Mbit/s -- -- x x 12.352/16.384 Mbit/s -- -- -- x x = valid, -- = invalid Generally the data or marker on the system interface are clocked off or latched on the rising or falling edge (SIC3.RESR/X) of the SCLKR/X clock. Some clocking rates allow transmission of time slots in different channel phases. Each channel phase which shall be active on ports RDO, XDI, RP(A:D) and XP(A:D) is programmable by bit SIC2.SICS(2:0), the remaining channel phases are cleared or ignored. The signals on pin SYPR in combination with the assigned time slot offset in register RC0 and RC1 define the beginning of a frame on the receive system highway. The signal on pin SYPX or XMFS together with the assigned time slot offset in register XC0 and XC1 define the beginning of a frame on the transmit system highway. Adjusting the frame begin (time slot 0, bit 0) relative to SYPR/X or XMFS is possible in the range of 0 to 125 µs. The minimum shift of varying the time slot 0 begin can be programmed between 1 bit and 1/8 bit depending of the system clocking and data rate, e.g. with a clocking/data rate of 2.048 MHz shifting is done bit by bit, while running the FALC56 with 16.384 MHz and 2.048 Mbit/s data rate it is done by 1/8 bit. A receive frame marker RFM can be activated during any bit position of the entire frame. Programming is done with registers RC1/0. The pin function RFM is selected by PC(4:1).RPC(2:0) = 001. The RFM selection disables the internal time slot assigner, no offset programming is performed. The receive frame marker is active high for one 1.544/ Data Sheet 165 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 2.048 MHz cycle and is clocked off with the rising or falling edge of the clock which is in/ output on port SCLKR (see SIC3.RESX/R). SCLKR DCO-R RSIGM Receive Signaling Buffer RSIG RMFB Receive Elastic Buffer RFM RP(A...D) DLR FREEZE RFSP SYPR Receive Backplane DCO-R BYP Receive Data Receive Jitter Attenuator Receive Clock RDO DCO-R SCLKX XLT Transmit Signaling Buffer XSIG SYPX XP(A...D) XMFS Transmit Backplane Transmit Elastic Buffer TCLK XSIGM XMFB DLX XCLK Transmit Data Transmit Clock Figure 54 Data Sheet BYP PLB XDI Transmit Jitter Attenuator TCLK RCLK F0118 System Interface (T1/J1) 166 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.5.1 Receive System Interface (T1/J1) RDO FRAME 1 FRAME 2 FRAME 3 ~~ ~~ (e.g. F12 Frame Format) FRAME 11 FRAME 12 FRAME 1 FRAME 2 ~ ~ RMFB SYPR SYPR Trigger Edge1) Sample Edge SCLKR 8.192 MHz T Programmable via RC0/1 SCLKR 1.544 MHz TS0 RDO/RSIG Bit 255 2 Mbit/s Data Rate Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 0 RDO/RSIG 4 Mbit/s Data Rate (SCLKR = 8.192 MHz) Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 255 RDO/RSIG Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 4 Mbit/s Data Rate (SCLKR = 8.192 MHz) 4 Mbit Interface RFM marks any bit position 2 Mbit Interface 2 Mbit Interface Receive Frame Marker RCO/1 4 Mbit Interface RSIGM Time-Slot Marker RTR1...4 marks any Time-Slot Sample Edge T Programmable via RC0/1 RDO 1.544 Mbit/s Data Rate (SCLKR = 1.544 MHz) Bit 192 FDL Bit 1 Bit 2 Bit 3 Bit 4 DLR DL Bit Marker 1.544 Mbit Interface 1) only falling trigger edge shown, depending on Bit SIC3.RESR Figure 55 Data Sheet ITD10949 Receive System Interface Clocking (T1/J1) 167 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.5.1.1 Receive Offset Programming Depending on the selection of the synchronization signals (SYPR or RFM), different calculation formulas are used to define the position of the synchronization pulses. These formulas are given below, see Figure 56 to Figure 59 for explanation. The pulse length of SYPR and RFM is always the basic T1/J1 bit width (648 ns) in 1.544-MHz mode or the E1 bit width (488 ns) in 2.048-MHz mode. This chapter describes the system highway operation in 1.544-MHz mode only. If the system highway is operated in 2.048-MHz mode, the description given in Chapter 4.5.1.1 on page 106 applies. SYPR Offset Calculation T: Time between beginning of SYPR pulse and beginning of next frame (time slot 0, bit 0), measured in number of SCLKR clock intervals maximum delay: Tmax = (193 × SC/SD) - 1 SD: Basic data rate; 1.544 Mbit/s SC: System clock rate; 1.544, 3.088, 6.176, or 12.352 MHz X: Programming value to be written to registers RC0 and RC1 (see page 359). 0 ≤ T ≤ 4: X = 4 - T + (7 × SC/SD) 5 ≤ T ≤ Tmax: X = (200 × SC/SD) + 4 - T RFM Offset Calculation MP: Marker position of RFM, counting in SCLKR clock cycles (0 = F-bit) SC = 1.544 MHz: SC = 3.088 MHz: SC = 6.176 MHz: SC = 12.352 MHz: 0 ≤ MP ≤ 192 0 ≤ MP ≤ 385 0 ≤ MP ≤ 771 0 ≤ MP ≤ 1543 SD: Basic data rate; 1.544 Mbit/s SC: System clock rate; 1.544, 3.088, 6.176, or 12.352 MHz X: Programming value to be written to registers RC0 and RC1 (see page 359). 0 ≤ MP ≤ 193 × (SC/SD) - 3: X = MP + 2 + (7 × SC/SD) 193 × (SC/SD) - 2 ≤ MP ≤ 193 × (SC/SD) - 1: X = MP + 2 - (186 × SC/SD) Data Sheet 168 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 TS0 RDO TS1 TS24 F123456 781234567 TS0 TS1 12345678F123456781234567 8 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) SYPR T=0 T SYPR T SYPR F0222A Figure 56 SYPR Offset Programming (1.544 Mbit/s, 1.544 MHz) TS0 RDO (CP0) RDO (CP1) RDO (CP2) RDO (CP3) F 1 F 2 1 F 3 2 1 F TS24 1 8 3 2 7 3 2 TS0 F 8 7 3 F 8 7 1 1 F 8 2 2 1 F 3 3 2 1 4 3 2 3 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) SYPR T=0 T SYPR T SYPR F0222B bit-interleaved (TS = time slot, CP = channel phase) Figure 57 Data Sheet SYPR Offset Programming (6.176 Mbit/s, 6.176 MHz) 169 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 TS0 RDO TS24 F123456 781234567 TS0 TS1 12345678F123456781234567 8 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) RFM BP = 0 RFM BP = 12 RFM BP = 188 (BP = bit position) Figure 58 F0222C RFM Offset Programming (1.544 Mbit/s, 1.544 MHz) TS0 RDO (CP0) RDO (CP1) RDO (CP2) RDO (CP3) F 1 F 2 1 F 3 2 1 F TS24 1 8 3 2 7 3 2 TS0 8 7 3 F F 8 7 1 1 F 8 2 2 1 F 3 3 2 1 4 3 2 3 SCLKR SIC3.RESR = 0 (falling edge) SCLKR SIC3.RESR = 1 (rising edge) RFM BP = 0 RFM BP = 12 RFM BP = 1020 Figure 59 Data Sheet bit-interleaved (TS = time slot, CP = channel phase, BP = bit position) F0222D RFM Offset Programming (6.176 Mbit/s, 6.176 MHz) 170 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 125 µs SYPR SCLKR T TS31 RDO 45 67 RSIG AB CD TS1 TS0 TS2 TS3 TS4 F0 12 34 5 67 0 12 34 5 67 0 12 34 5 67 ABCD ABCD A BCD FS/DLchannel T F ABCD Figure 60 0 12 3 ABCD Idle-channel = Time slot offset (RC0, RC1) = FS/DL-bit = Signaling bits for time slots 1...24, time slot mapping according to channel translation mode 0 F0135 2.048 MHz Receive Signaling Highway (T1/J1) FS/DL Time-Slot MSB 1 2 3 4 5 6 7 LSB 8 FS/DL FS/DL Data Bit ITD06460 Figure 61 Data Sheet Receive FS/DL-Bits in Time Slot 0 on RDO (T1/J1) 171 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 125 µs SYPR SCLKR T TS23 TS0 TS1 TS23 RDO 45 67F 01 2 34 56 7 01 23 4 56 7 RSIG AB CD F A BCD A BCD A BCD F ESF RSIG ABAB F ABAB ABAB ABABF F12 T F ABCD, ABAB Figure 62 5.5.2 0 1 23 45 6 7F = Time slot offset (RC0, RC1) = FS/DL-bit = Signaling bits for time slots 1...23 F0134 1.544 MHz Receive Signaling Highway (T1/J1) Transmit System Interface (T1/J1) Compared to the receive paths the inverse functions are performed for the transmit direction. The interface to the transmit system highway is realized by two data buses, one for the data XDI and one for the signaling data XSIG. The time slot assignment is equivalent to the receive direction. All unequipped (idle) time slots are ignored. Latching of data is controlled by the system clock (SCLKX or SCLKR) and the synchronization pulse (SYPX/XMFS) in combination with the programmed offset values for the transmit time slot/clock slot counters XC1/0. The frequency of the working clock 2.048/4.096/8.192/16.384 MHz or 1.544/3.088/6.176/12.352 MHz for the transmit system interface is programmable by SIC1.SSC1/0 and SIC2.SSC2. Refer also Table 44. The received bit stream on ports XDI and XSIG can be multiplexed internally on a time slot basis, if enabled by SIC3.TTRF = 1. The data received on port XSIG can be sampled if the transmit signaling marker XSIGM is active high. Data on port XDI is sampled if XSIGM is low for the corresponding time slot. Programming the XSIGM marker is done with registers TTR(4:1). Note: XSIG is required in the last frame of a multiframe only and ignored in all other frames. Data Sheet 172 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 XDI FRAME1 FRAME2 FRAME3 FRAME12 FRAME1 FRAME2 FRAME3 XMFB XMFS SYPX Bit 0 Sample Edge 1) Trigger Edge 1) SYPX T 2) SCLKX XSIGM Time Slot Marker FDL XDI Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 DLX DL Bit Marker 1) 2) Figure 63 Data Sheet only falling edge mode shown delay T is programmable by XC0/1; F0005 Transmit System Clocking: 1.544 MHz (T1/J1) 173 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 XDI FRAME1 FRAME2 FRAME3 FRAME12 FRAME1 FRAME2 FRAME3 XMFS SYPX Bit 0 Sample Edge 1) Trigger Edge 1) SYPX T 2) SCLKX XSIGM Time-Slot Marker XTR1...4 SIC2.SICS2-0=000(001) XDI/XSIG 1 SIC2.SICS2-0=000 2 3 4 5 XDI/XSIG 6 7 8 1 SIC2.SICS2-0=001 2 3 4 5 6 7 8 DLX DL-Bit Marker SIC2.SICS2-0=000 DLX DL-Bit Marker SIC2.SICS2-0=001 1) 2) Figure 64 Data Sheet only falling edge mode shown delay T is programmable by XC0/1; F0006 Transmit System Clocking: 8.192 MHz/4.096 Mbit/s (T1/J1) 174 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 125 µs SYPX SCLKX T TS31 XDI 45 67 XSIG AB CD TS1 TS0 TS2 TS3 F0 12 34 5 67 0 12 34 5 67 0 12 34 5 67 ABCD ABCD A BCD FS/DLchannel T F ABCD Figure 65 TS4 0 12 3 ABCD Idle-channel = Time slot offset (RC0, RC1) = FS/DL-bit = Signaling bits for time slots 1...24, time slot mapping according to channel translation mode 0, read only during last frame of a multiframe F0136 2.048 MHz Transmit Signaling Clocking (T1/J1) 125 µs SYPX SCLKX T TS23 TS0 TS1 TS23 XDI 45 67F 01 2 34 56 7 01 23 4 56 7 XSIG AB CD F A BCD A BCD A BCD F ESF XSIG ABAB F ABAB ABAB ABABF F12 T F ABCD ABAB Figure 66 Data Sheet 0 1 23 45 6 7F = Time slot offset (RC0, RC1) = FS/DL-bit = ESF signaling bits for time slots 1...23 read only during last frame of a multiframe, = F12 signaling bits for time slots 1...23 read only during last frame of a multiframe (bit positions 4/5) F0137 1.544 MHz Transmit Signaling Highway (T1/J1) 175 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Multiframe n (e.g. F12) Frame 2 Frame 3 Frame 12 ~ ~ Frame 1 ~ ~ RD0 XDI RMFB XMFB RD0 XDI 24 FS/ 1 DL ~ ~ Signals in channel translation mode 0 2 3 4 5 6 7 8 9 19 20 21 22 23 24 FS/ DL RSIGM1) XSIGM 2 16 17 18 19 20 21 22 23 24 ~ ~ FS/ 1 DL RD0 XDI ~ ~ Signals in channel translation mode 1 FS/ 1 DL RSIGM1) XSIGM 1) RSIGM and XSIGM are programed via registers RTR1... 4 / TTR1... 4 to mark only channel 24 ITD06462 Figure 67 Signaling Marker for CAS/CAS-CC Applications (T1/J1) Data Sheet 176 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 Multiframe n (e.g.F12) Frame 6 Frame 12 ~ ~ ~ ~ RD0 XDI ~ ~ Frame 2 ~ ~ Frame 1 RMFB XMFB RD0 XDI 24 FS/ 1 DL ~ ~ Signals in channel translation mode 0 2 3 4 5 6 7 8 9 19 20 21 22 23 24 FS/ DL Signals in frames 6 and 12 of each multiframe 1) ~ ~ RSIGM XSIGM 2 16 17 18 19 20 21 22 23 24 ~ ~ FS/ 1 DL RD0 XDI ~ ~ Signals in channel translation mode 1 FS/ 1 DL Signals in frames 6 and 12 of each multiframe 1) Figure 68 Data Sheet ~ ~ 1) RSIGM XSIGM RSIGM and XSIGM will mark the robbed bit positions if XCO.BRM is set high ITD06463 Signaling Marker for CAS-BR Applications (T1/J1) 177 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 FS/DL data on system transmit highway (XDI), time slot 0: FS/DL Time-Slot MSB 1 2 3 4 5 6 7 LSB 8 FS/DL FS/DL Data Bit ITD06460 Figure 69 5.5.2.1 Transmit FS/DL Bits on XDI (T1/J1) Transmit Offset Programming The pulse length of SYPR and RFM is always the basic T1/J1 bit width (648 ns) in 1.544MHz mode or the E1 bit width (488 ns) in 2.048-MHz mode. This chapter describes the system highway operation in 1.544-MHz mode only. If the system highway is operated in 2.048-MHz mode, the description given in Chapter 4.5.2.1 on page 111 applies. SYPX Offset Calculation T: Time between the active edge of SCLKX after SYPX pulse begin and beginning of the next frame (F-bit, channel phase 0), measured in number of SCLKX clock intervals; maximum delay: Tmax = (200 × SC/BF) - (7 × SC/BF) - 1 BF: Basic frequency; 1.544 Mbit/s SC: System clock rate; 1.544, 3.088, 6.176, or 12.352 MHz X: Programming value to be written to registers RC0 and RC1 (see page 356). 0 ≤ T ≤ 4: X = 3 - T + (7 × SC/BF) 5 ≤ T ≤ Tmax: X = (200 × SC/BF) - T + 3 Data Sheet 178 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 TS1 XDI TS2 TS24 F123456 781234567 TS1 TS2 12345678F123456781234567 8 SCLKX SIC3.RESX = 1 (rising edge) SCLKX SIC3.RESX = 0 (falling edge) SYPX T=0 T SYPX T SYPX F0224A Figure 70 SYPX Offset Programming (1.544 Mbit/s, 1.544 MHz) TS1 XDI (CP0) XDI (CP1) XDI (CP2) XDI (CP3) F 1 F 2 1 F 3 2 1 F TS24 1 8 3 2 7 3 2 TS1 F 8 7 3 F 8 7 1 1 F 8 2 2 1 F 3 3 2 1 4 3 2 3 SCLKX SIC3.RESX = 1 (rising edge) SCLKX SIC3.RESX = 0 (falling edge) SYPX T=0 T SYPX T SYPX bit-interleaved (TS = time slot) Figure 71 Data Sheet F0224B SYPX Offset Programming (6.176 Mbit/s, 6.176 MHz) 179 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.5.3 Time Slot Assigner (T1/J1) HDLC channel 1 offers the flexibility to connect data during certain time slots, as defined by registers RTR(4:1) and TTR(4:1), to the RFIFO and XFIFO, respectively. Any combinations of time slots can be programmed for the receive and transmit directions. If CCR1.EITS = 1 the selected time slots (RTR(4:1)) are stored in the RFIFO of the signaling controller and the XFIFO contents is inserted into the transmit path as controlled by registers TTR(4:1). For HDLC channels 2 and 3, one out of 24 time slots can be selected for each channel, but in common for transmit and receive direction. Within selected time slots single bit positions can be masked to be used/not used for HDLC transmission for all HDLC channels. Additionally, the use of even, odd or both frames can be selected for each HDLC channel individually. Table 45 Time Slot Assigner HDLC Channel 1 (T1/J1) Receive Time Slot Register Transmit Time Slot Register Time Slots Receive Time Slot Register Transmit Time Slot Register Time Slots RTR 1.7 TTR 1.7 0 RTR 3.7 TTR 3.7 16 RTR 1.6 TTR 1.6 1 RTR 3.6 TTR 3.6 17 RTR 1.5 TTR 1.5 2 RTR 3.5 TTR 3.5 18 RTR 1.4 TTR 1.4 3 RTR 3.4 TTR 3.4 19 RTR 1.3 TTR 1.3 4 RTR 3.3 TTR 3.3 20 RTR 1.2 TTR 1.2 5 RTR 3.2 TTR 3.2 21 RTR 1.1 TTR 1.1 6 RTR 3.1 TTR 3.1 22 RTR 1.0 TTR 1.0 7 RTR 3.0 TTR 3.0 23 RTR 2.7 TTR 2.7 8 RTR 4.7 TTR 4.7 24 RTR 2.6 TTR 2.6 9 RTR 4.6 TTR 4.6 25 RTR 2.5 TTR 2.5 10 RTR 4.5 TTR 4.5 26 RTR 2.4 TTR 2.4 11 RTR 4.4 TTR 4.4 27 RTR 2.3 TTR 2.3 12 RTR 4.3 TTR 4.3 28 RTR 2.2 TTR 2.2 13 RTR 4.2 TTR 4.2 29 RTR 2.1 TTR 2.1 14 RTR 4.1 TTR 4.1 30 RTR 2.0 TTR 2.0 15 RTR 4.0 TTR 4.0 31 Data Sheet 180 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 The format for receive FS/DL data transmission in time slot 0 of the system interface is as shown in Figure 63 below. In order to get an undisturbed reception even in the asynchronous state bit FMR2.DAIS has to be set. Data Sheet 181 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.6 Test Functions (T1/J1) 5.6.1 Pseudo-Random Binary Sequence Generation and Monitor The FALC56 has the added ability to generate and monitor a 215-1 and 220-1 PseudoRandom Binary Sequences (PRBS). The generated PRBS pattern is transmitted to the remote end on pins XL1/2 or XDOP/N and can be inverted optionally. Generating and monitoring of PRBS pattern is done according to ITU-T O.151 and TR62411 with maximum 14 consecutive zero restriction. The PRBS monitor senses the PRBS pattern in the incoming data stream. Synchronization is done on the inverted and non-inverted PRBS pattern. The current synchronization status is reported in status and interrupt status registers. Enabled by bit LCR1.EPRM each PRBS bit error increments an error counter (BEC). Synchronization is reached within 400 ms with a probability of 99.9% and a bit error rate of up to 10-1. The PRBS generator and monitor can be used to handle either a framed (TPC0.FRA = 1) or an unframed (TPC0.FRA = 0) data stream. 5.6.2 Remote Loop In the remote loop-back mode the clock and data recovered from the line inputs RL1/2 or RDIP/RDIN are routed back to the line outputs XL1/2 or XDOP/XDON through the analog or digital transmitter. As in normal mode they are also processed by the synchronizer and then sent to the system interface.The remote loop-back mode is selected by setting the corresponding control bits LIM1.RL+JATT. Received data is looped with or without use of the transmit jitter attenuator (FIFO). RCLK RL1 RL2 Clock + Data Recovery Rec. Framer Elast. Store RDO Trans. Framer Elast. Store XDI FIFO XL1 MUX XL2 XCLK Figure 72 Data Sheet MUX RCLK DCO-R/X ITS09750 Remote Loop (T1/J1) 182 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.6.3 Payload Loop-Back To perform an effective circuit test a line loop is implemented. If the payload loop-back (FMR2.PLB) is activated the received 192 bits of payload data is looped back to the transmit direction. The framing bits, CRC6 and DL-bits are not looped, if FMR4.TM = 0. They are originated by the FALC56 transmitter. If FMR4.TM = 1 the received FS/DL-bit is sent transparently back to the line interface. Following pins are ignored: XDI, XSIG, TCLK, SCLKX, SYPX and XMFS. All the received data is processed normally. With bit FMR2.SAIS an AIS can be sent to the system interface on pin RDO. RCLK RL1 RL2 AIS-GEN MUX Clock + Data Recovery Rec. Framer Elast. Store RDO SCLKR XL1 XL2 Elast. Store Trans. Framer XDI SCLKX ITS09748 Figure 73 Data Sheet Payload Loop (T1/J1) 183 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.6.4 Local Loop The local loop-back mode, selected by LIM0.LL = 1, disconnects the receive lines RL1/ 2 or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data provided by system interface are routed through the analog receiver back to the system interface. However, the bit stream is transmitted undisturbedly on the line. An AIS to the distant end can be enabled by setting FMR1.XAIS without influencing the data looped back to the system interface. Note that enabling the local loop usually invokes an out of frame error until the receiver resynchronizes to the new framing. The serial codes for transmitter and receiver have to be identical. RCLK RL2 Clock + Data Recovery Rec. Framer Elast. Store RDO XL1 MUX Trans. Framer Elast. Store XDI RL1 XL2 AIS-GEN ITS09749 Figure 74 Data Sheet Local Loop (T1/J1) 184 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.6.5 Single Channel Loop-Back (loop-back of time slots) The channel loop-back is selected by LOOP.ECLB = 1. Each of the 24 time slots can be selected for loop-back from the system PCM input (XDI) to the system PCM output (RDO). This loop-back is programmed for one time slot at a time selected by register LOOP. During loop-back, an idle channel code programmed in register IDLE is transmitted to the remote end in the corresponding PCM route time slot. For the time slot test, sending sequences of test patterns like a 1-kHz check signal should be avoided. Otherwise an increased occurrence of slips in the tested time slot disturbs testing. These slips do not influence the other time slots and the function of the receive memory. The usage of a quasi-static test pattern is recommended. RCLK RL1 RL2 XL1 XL2 Clock + Data Recovery Trans. Framer Rec. Framer MUX MUX IDLE Code Figure 75 Data Sheet Elast. Store RDO Elast. Store XDI ITS09747 Channel Loop-Back (T1/J1) 185 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.6.6 Alarm Simulation (T1/J1) Alarm simulation does not affect the normal operation of the device, i.e. all time slots remain available for transmission. However, possible real alarm conditions are not reported to the processor or to the remote end when the device is in the alarm simulation mode. The alarm simulation is initiated by setting the bit FMR0.SIM. The following alarms are simulated: • • • • • • • • Loss-Of-Signal (LOS, red alarm) Alarm indication signal (AIS, blue alarm) Loss of pulse frame Remote alarm (yellow alarm) indication Receive and transmit slip indication Framing error counter Code violation counter CRC6 error counter Some of the above indications are only simulated if the FALC56 is configured in a mode where the alarm is applicable. The alarm simulation is controlled by the value of the alarm simulation counter: FRS2.ESC which is incremented by setting bit FMR0.SIM. Clearing of alarm indications: • Automatically for LOS, remote (yellow) alarm, AIS, and loss of synchronization and • User controlled for slips by reading the corresponding interrupt status register ISR3. • Error counter have to be cleared by reading the corresponding counter registers. is only possible at defined counter steps of FRS2.ESC. For complete simulation (FRS2.ESC = 0), eight simulation steps are necessary. 5.6.7 Single Bit Defect Insertion Single bit defects can be inserted into the transmit data stream for the following functions: FAS defect, multiframe defect, CRC defect, CAS defect, PRBS defect and bipolar violation. Defect insertion is controlled by register IERR. Data Sheet 186 2002-08-27 FALC56 V1.2 PEB 2256 Functional Description T1/J1 5.7 J1-Feature Overview The Japanese J1 standard is very similar to the T1 standard, but differs in some details. To support these differences easily, the following features are provided within the FALC56: • CRC6 generation and checking according to ITU-JT G.706 (CRC checksum calculation includes FS/DL-bits, see Chapter 5.2.6.3 on page 146) • Remote alarm handling according to ITU-JT G.704 (remote alarm pattern in DL-channel is "1111111111111111", see Chapter 5.2.6.2 on page 146) • NTT synchronization requirements in ESF framing mode • Pulse shaping according to JT G.704 • Receive input thresholds according to ITU-JT G.703 J1 mode is globally selected by setting RC0.SJR = 1 (see page 357). For specific J1 framer initialization see Table 55 on page 199. No special pulse mask setting is required, the described T1-settings also fulfill the J1 requirements. Data Sheet 187 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description E1 6 Operational Description E1 6.1 Operational Overview E1 The FALC56 can be operated in two modes, which are either E1 mode or T1/J1 mode. The device is programmable via a microprocessor interface which enables byte or word access to all control and status registers. After reset the FALC56 must be initialized first. General guidelines for initialization are described in Chapter 6.3. The status registers are read-only and are updated continuously. Normally, the processor reads the status registers periodically to analyze the alarm status and signaling data. 6.2 Device Reset E1 The FALC56 is forced to the reset state if a low signal is input on pin RES for a minimum period of 10 µs. During reset the FALC56 needs an active clock on pin MCLK. All output stages are in a high-impedance state, all internal flip-flops are reset and most of the control registers are initialized with default values. SIgnals (for example RL1/2 receive line) should not be applied before the device is powered up. After reset the device is initialized to E1 operation. 6.3 Device Initialization in E1 Mode After reset, the FALC56 is initialized for doubleframe format with register values listed in the following table. Table 46 Initial Values after Reset (E1) Register Reset Value Meaning FMR0 00H NRZ Coding, no alarm simulation. FMR1 FMR2 00H E1-doubleframe format, 2 Mbit/s system data rate, no AIS transmission to remote end or system interface, payload loop off. SIC1 SIC2, SIC3 00H 00H 00H 8.192 MHz system clocking rate, receive buffer 2 frames, transmit buffer bypass, data sampled or transmitted on the falling edge of SCLKR/X, automatic freeze signaling, data is active in the first channel phase Data Sheet 188 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description E1 Table 46 Initial Values after Reset (E1) (cont’d) Register Reset Value Meaning LOOP XSW XSP TSWM 00H 00H 00H 00H Channel loop-back and single frame mode are disabled. All bits of the transmitted service word are cleared. Spare bit values are cleared. No transparent mode active. XC0 XC1 00H 9CH The transmit clock offset is cleared. The transmit time slot offset is cleared. RC0 RC1 00H 9CH The receive clock slot offset is cleared. The receive time slot offset is cleared. IDLE ICB(4:1) 00H 00H Idle channel code is cleared. Normal operation (no “Idle Channel” selected). LIM0 LIM1 PCD PCR 00H 00H 00H 00H Slave Mode, local loop off Analog interface selected, remote loop off Pulse count for LOS detection cleared Pulse count for LOS recovery cleared XPM(2:0) 40H, 03H, 7BH Transmit pulse mask (transmitter in tristate mode) IMR(5:0) FFH All interrupts are disabled RTR(4:1) TTR(4:1) TSS2 TSS3 all 00H all 00H 00H 00H No time slots selected GCR 00H Internal second timer, power on CMR1 00H RCLK output: DPLL clock, DCO-X enabled, DCO-X internal reference clock CMR2 00H SCLKR selected, SCLKX selected, receive synchronization pulse sourced by SYPR, transmit synchronization pulse sourced by SYPX PC(4:1) 00H, 00H 00H, 00H Input function of ports RP(A to D): SYPR, Input function of ports XP(A to D): SYPX PC5 PC6 00H 00H SCLKR, SCLKX, RCLK configured to inputs, XMFS active low, CLK1 and CLK2 pin configuration MODE MODE2 MODE3 00H 00H 00H Signaling controller disabled Data Sheet 189 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description E1 Table 46 Initial Values after Reset (E1) (cont’d) Register Reset Value Meaning RAH(2:1) RAL(2:1) FDH, FFH FFH, FFH Compare register for receive address cleared GCM(6:1) all 00H Fixed clock mode selected (2.048 MHz on pin MCLK required). E1 Initialization For a correct start up of the primary access interface a set of parameters specific to the system and hardware environment must be programmed after reset goes inactive. Both the basic and the operational parameters must be programmed before the activation procedure of the PCM line starts. Such procedures are specified in ITU-T and ETSI recommendations (e.g. fault conditions and consequent actions). Setting optional parameters primarily makes sense when basic operation via the PCM line is guaranteed. Table 47 gives an overview of the most important parameters in terms of signals and control bits which are to be programmed in one of the above steps. The sequence is recommended but not mandatory. Accordingly, parameters for the basic and operational set up, for example, can be programmed simultaneously. The bit FMR1.PMOD should always be kept low (otherwise T1/J1 mode is selected). Table 47 Initialization Parameters (E1) Basic Set Up Master clocking mode GCM(6:1) according to external MCLK clock frequency E1 mode select FMR1.PMOD = 0 Specification of line interface and clock generation LIM0, LIM1, XPM(2:0) Line interface coding FMR0.XC(1:0), FMR0.RC(1:0) Loss-of-signal detection/recovery conditions PCD, PCR, LIM1, LIM2 System clocking and data rate SIC1.SSCC(1:0), SIC1.SSD1,FMR1.SSD0 CMR2.IRSP/IRSC/IXSP/IXSC Transmit offset counters XC0.XCO, XC1.XTO Receive offset counters RC0.RCO, RC1.RTO AIS to system interface FMR2.DAIS/SAIS Data Sheet 190 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description E1 Table 47 Initialization Parameters (E1) (cont’d) Operational Set Up Select framing FMR2.RFS(1:0), FMR1.XFS Framing additions RC1.ASY4, RC1.SWD Synchronization mode FMR1.AFR, FMR2.ALMF Signaling mode XSP, XSW, FMR1.ENSA, XSA(8:4), TSWM, MODE, CCR1, CCR2, RAH(2:1), RAL(2:1) Features like channel loop-back, idle channel activation, extensions for signaling support, alarm simulation, etc. are activated later. Transmission of alarms (e.g. AIS, remote alarm) and control of synchronization in connection with consequent actions to remote end and internal system depend on the activation procedure selected. Note: Read access to unused register addresses: value should be ignored. Write access to unused register addresses: should be avoided, or set to “00” hex. All control registers (except XFIFO, XS(16:1), CMDR, DEC) are of type Read/ Write. Specific E1 Register Settings The following is a suggestion for a basic initialization to meet most of the E1 requirements. Depending on different applications and requirement any other initialization can be used. Table 48 Line Interface Initialization (E1) FMR0.XC0/ FMR0.RC0/ LIM1.DRS FMR3.CMI The FALC56 supports requirements for the analog line interface as well as the digital line interface. For the analog line interface the codes AMI and HDB3 are supported. For the digital line interface modes (dual- or single-rail) the FALC56 supports AMI, HDB3, CMI (with and without HDB3 precoding) and NRZ. PCD = 0AH LOS detection after 176 consecutive “zeros” (fulfills G.775). PCR = 15H LOS recovery after 22 “ones” in the PCD interval. (fulfills G.775). LIM1.RIL(2:0) = 02H LOS threshold of 0.6 V (fulfills G.775). E1 Framer Initialization The selection of the following modes during the basic initialization supports the ETSI requirements for E-Bit Access, remote alarm and synchronization (please refer also to FALC56 driver code of the evaluation system EASY22554 and application notes) and Data Sheet 191 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description E1 helps to reduce the software load. They are very helpful especially to meet requirements as specified in ETS300 011. Table 49 Framer Initialization (E1) XSP.AXS = 1 ETS300 011 C4.x for instance requires the sending of E-Bits in TS0 if CRC4 errors have been detected. By programming XSP.AXS = 1 the submultiframe status is inserted automatically in the next outgoing multiframe. XSP.EBP = 1 If the FALC56 has reached asynchronous state the E-Bit is cleared if XSP.EBP = 0 and set if XSP.EBP = 1. ETS300 011 requires that the E-Bit is set in asynchronous state. FMR2.AXRA = 1 The transmission of RAI via the line interface is done automatically by the FALC56 in case of loss of frame alignment (FRS0.LFA = 1). If basic framing has been reinstalled RAI is automatically reset. FMR2.FRS(2:1) = 10 FMR1.AFR = 1 In this mode a search of double framing is automatically restarted, if no CRC4 multiframing is found within 8ms. Together with FMR2.AXRA = 1 this mode is essential to meet ETS300 011 and reduces the processor load heavily. FMR2.ALMF = 1 The receiver initiates a new basic- and multiframing research if more than 914 CRC4 errors have been detected in one second. FMR2.FRS1/0 = 11 In the interworking mode the FALC56 stays in double framing format if no multiframe pattern is found in a time interval of 400 ms. This is also indicated by a 400 ms interrupt. Additionally the extended interworking mode (FMR3.EXTIW = 1) will activate after 400 ms the remote alarm (FMR2.AXRA = 1) and will still search the multiframing without switching completely to the double framing. A complete resynchronization in an 8 ms interval is not initiated. Table 50 HDLC Controller Initialization (E1) MODE = 88H MODE2= 88H MODE3= 88H HDLC channel 1 receiver active, no address comparison. HDLC channel 2 receiver active, no address comparison. HDLC channel 2 receiver active, no address comparison. CCR1 = 18H Enable signaling via TS(31:0), interframe time fill with continuous flags (channel 1). Interframe time fill with continuous flags (channel 2). Interframe time fill with continuous flags (channel 3). CCR3= 08H CCR4= 08H Data Sheet 192 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description E1 Table 50 HDLC Controller Initialization (E1) (cont’d) IMR0.RME = 0 IMR0.RPF = 0 IMR1.XPR = 0 IMR4.RME2=0 IMR4.RPF2=0 IMR5.XPR2=0 IMR5.RME3=0 IMR5.RPF3=0 IMR5.XPR3=0 Unmask interrupts for HDLC processor requests. RTR3.TS16 = 1 TTR3.TS16 = 1 TSEO = 00H Select TS16 for HDLC data reception and transmission. TSBS1 = FFH TSBS2= FFH TSBS3= FFH TSS2= 01H TSS3= 02H Table 51 Even and odd frames are used for HDLC reception and transmission. Select all bits of selected time slot (channel 1). Select all bits of selected time slot (channel 2). Select all bits of selected time slot (channel 3). Select time slot 1 for HDLC channel 2. Select time slot 2 for HDLC channel 3. CAS-CC Initialization (E1) XSP.CASEN = 1 CCR1.EITS = 0 Send CAS info stored in the XS(16:1) registers. IMR0.CASC = 0 Enable interrupt with any data change in the RS(16:1) registers. Note: After the device initialization a software reset should be executed by setting of bits CMDR.XRES/RRES. Data Sheet 193 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 7 Operational Description T1/J1 7.1 Operational Overview T1/J1 The FALC56 can be operated in two principle modes, which are either E1 mode or T1/ J1 mode. The device is programmable via a microprocessor interface which enables byte or word access to all control and status registers. After reset the FALC56 must be initialized first. General guidelines for initialization are described in Chapter 7.3 The status registers are read-only and are updated continuously. Normally, the processor reads the status registers periodically to analyze the alarm status and signaling data. 7.2 Device Reset T1/J1 The FALC56 is forced to the reset state if a low signal is input on pin RES for a minimum period of 10 µs. During reset the FALC56 needs an active clock on pin MCLK. All output stages are in a high-impedance state, all internal flip-flops are reset and most of the control registers are initialized with default values. SIgnals (for example RL1/2 receive line) should not be applied before the device is powered up. After reset the device is initialized to E1 operation. 7.3 Device Initialization in T1/J1 Mode After reset, the FALC56 is initialized for E1 doubleframe format. To initialize T1/J1 mode, bit FMR1.PMOD has to be set high. After the internal clocking is settled to T1/J1mode (takes up to 20 µs), the following register values are initialized: . Table 52 Initial Values after reset and FMR1.PMOD = 1 (T1/J1) Register Initiated Value Meaning FMR0 00H NRZ coding, no alarm simulation FMR1 FMR2 00H 00H PCM24 mode, 2.048 Mbit/s system data rate, no AIS transmission to remote end or system interface, payload loop off, channel translation mode 0 Data Sheet 194 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 Table 52 Initial Values after reset and FMR1.PMOD = 1 (T1/J1) (cont’d) Register Initiated Value Meaning SIC1 SIC2, SIC3 00H 00H 00H 2.048 MHz system clocking rate, receive buffer 2 frames, transmit buffer bypass, data sampled or transmitted on the falling edge of SCLKR/X, automatic freeze signaling, data is active in the first channel phase LOOP 00H loop-backs are disabled. FMR4 FMR5 00H 00H Remote alarm indication towards remote end is disabled. LFA condition: 2 out of 4/5/6 framing bits, non-autosynchronization mode, F12 multiframing, internal bit robbing access disabled XC0 XC1 00H 9CH The transmit clock slot offset is cleared. The transmit time slot offset is cleared. RC0 RC1 00H 9CH The receive clock slot offset is cleared. The receive time slot offset is cleared. IDLE ICB(3:1) 00H 00H Idle channel code is cleared. Normal operation (no “Idle Channels” selected). CCB(3:1) 00H Normal operation (no clear channel operation). LIM0 LIM1 PCD PCR 00H 00H 00H 00H Slave mode, local loop off, analog interface selected, remote loop off pulse count for LOS detection cleared pulse count for LOS recovery cleared XPM(2:0) 40H,03H,7BH Transmit pulse mask (transmitter in tristate mode) IMR(5:0) FFH All interrupts are disabled GCR 00H Internal second timer, power on CMR1 00H RCLK output: DPLL clock, DCO-X enabled, DCO-X internal reference clock CMR2 00H SCLKR selected, SCLKX selected, receive synchronization pulse sourced by SYPR, transmit synchronization pulse sourced by SYPX GPC1 00H SEC port input active high PC(4:1) 00H, 00H 00H, 00H Input function of ports RP(A to D): SYPR, Input function of ports XP(A to D): SYPX PC5 PC6 00H 00H SCLKR, SCLKX, RCLK configured to inputs, XMFS active low, CLK1 and CLK2 pin configuration Data Sheet 195 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 Table 52 Initial Values after reset and FMR1.PMOD = 1 (T1/J1) (cont’d) Register Initiated Value Meaning MODE MODE2 MODE3 00H 00H 00H Signaling controller disabled RAH(2:1) RAL(2:1) FDH, FFH FFH, FFH Compare register for receive address cleared GCM(6:1) all 00H Fixed clock mode selected (1.544 MHz on pin MCLK required). RTR(4:1) TTR(4:1) TSS2 TSS3 all 00H all 00H 00H 00H No time slots selected T1/J1 Initialization For a correct start up of the primary access interface a set of parameters specific to the system and hardware environment must be programmed after RES goes inactive (high). Both the basic and the operational parameters must be programmed before the activation procedure of the PCM line starts. Such procedures are specified in ITU-T recommendations (e.g. fault conditions and consequent actions). Setting optional parameters primarily makes sense when basic operation via the PCM line is guaranteed. Table 53 gives an overview of the most important parameters in terms of signals and control bits which are to be programmed in one of the above steps. The sequence is recommended but not mandatory. Accordingly, parameters for the basic and operational set up, for example, can be programmed simultaneously. The bit FMR1.PMOD must always be kept high (otherwise E1 mode is selected). J1 mode is selected by additionally setting RC0.SJR = 1. Features like channel loop-back, idle channel activation, clear channel activation, extensions for signaling support, alarm simulation, etc. are activated later. Transmission of alarms (e.g. AIS, remote alarm) and control of synchronization in connection with consequent actions to remote end and internal system depend on the activation procedure selected. Data Sheet 196 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 , Table 53 Initialization Parameters (T1/J1) Basic Set Up T1 J1 Master clocking mode GCM(6:1) according to external MCLK clock frequency T1/J1 mode select FMR1.PMOD = 1, RC0.SJR = 0 Specification of line interface and clock generation LIM0, LIM1, XPM(2:0) Line interface coding FMR0.XC(1:0), FMR0.RC(1:0) Loss-of-signal detection/ recovery conditions PCD, PCR, LIM1, LIM2 System clocking and data rate SIC1.SSC(1:0), SIC1.SSD1, FMR1.SSD0, CMR1.IRSP/ IRSC/IXSP/IXSC Channel translation mode FMR1.CTM Transmit offset counters XC0.XCO, XC1.XTO Receive offset counters RC0.RCO, RC1.RTO AIS to system interface FMR2.DAIS/SAIS FMR1.PMOD = 1, RC0.SJR = 1 Operational Set Up Select framing FMR4.FM(1:0) Framing additions FMR1.CRC, FMR0.SRAF Synchronization mode FMR4.AUTO, FMR4.SSC(1:0), FMR2.MCSP, FMR2.SSP Signaling mode FMR5.EIBR, XC0.BRM, MODE, MODE2, MODE3, CCR1, CCR2, RAH(2:1), RAL(2:1) Note: Read access to unused register addresses: value should be ignored. Write access to unused register addresses: should be avoided, or set to “00”hex. All control registers (except XFIFO, XS(12:1), CMDR, DEC) are of type read/write Data Sheet 197 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 Specific T1/J1 Initialization The following is a suggestion for a basic initialization to meet most of the T1/J1 requirements. Depending on different applications and requirements any other initialization can be used. Table 54 Line Interface Initialization (T1/J1) Register Function FMR0.XC0/1 FMR0.RC0/1 LIM1.DRS CCB(3:1) SIC3.CMI The FALC56 supports requirements for the analog line interface as well as the digital line interface. For the analog line interface the codes AMI (with and without bit 7stuffing) and B8ZS are supported. For the digital line interface modes (dual- or single-rail) the FALC56 supports AMI (with and without bit 7 stuffing), B8ZS (with and without B8ZS precoding) and NRZ. PCD = 0AH LOS detection after 176 consecutive “zeros” (fulfills G.775/ Telcordia (Bellcore)/AT&T) PCR = 15H LOS recovery after 22 “ones” in the PCD interval (fulfills G.775, Bellcore/AT&T). LIM1.RIL(2:0) = 02H LOS threshold of 0.6 V (fulfills G.775). GCR.SCI = 1 Additional Recovery Interrupts. Help to meet alarm activation and deactivation conditions in time. LIM2.LOS1 = 1 Automatic pulse-density check on 15 consecutive zeros for LOS recovery condition (Bellcore requirement) Data Sheet 198 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 Table 55 Framer Initialization (T1/J1) Register Function T1 J1 FMR4.SSC1/0 Selection of framing sync conditions FMR4.FM1/0 Select framing format FMR2.AXRA = 1 The transmission of RAI via the line interface is done automatically by the FALC56 in case of Loss of Frame Alignment (FRS0.LFA = 1). If framing has been reinstalled RAI is automatically reset FMR4.AUTO = 1 Automatic synchronization in case of definite framing candidate (FRS0.FSRF). In case of multiple framing candidates and CRC6 errors different resynchronization conditions can be programmed via FMR2.MCSP/SSP. RCO.SJR1) = 1 FMR0.SRAF = 0 XSW.XRA = 1 Remote alarm handling via DLchannel according to ITU-T JG.704 using pattern "1111111111111111" RCO.SJR = 0 CRC6 calculation without FS/ DL-bits RCO.SJR = 1 FMR4.AUTO = 1 CRC6 calculation including FS/ DL-bits Automatic synchronization in case of definite framing candidate (FRS0.FSRF). In case of multiple framing candidates and CRC6 errors different resynchronization conditions can be programmed via FMR2.MCSP/SSP. FMR4.SSC1 = 1 FMR4.SSC0 = 1 FMR2.MCSP = 0 FMR2.SSP = 1 1) Synchronization and resynchronization conditions, for details see register description Remote alarm handling and CRC6 calculation are commonly selected by RC0.SJR Data Sheet 199 2002-08-27 FALC56 V1.2 PEB 2256 Operational Description T1/J1 Table 56 HDLC Controller Initialization (T1/J1) MODE = 88H MODE2= 88H MODE3= 88H HDLC channel 1 receiver active, no address comparison. HDLC channel 2 receiver active, no address comparison. HDLC channel 2 receiver active, no address comparison. CCR1 = 18H Enable signaling via TS(24:1), interframe time fill with continuous flags (channel 1). Interframe time fill with continuous flags (channel 2). Interframe time fill with continuous flags (channel 3). CCR3= 08H CCR4= 08H IMR0.RME = 0 IMR0.RPF = 0 IMR1.XPR = 0 IMR4.RME2=0 IMR4.RPF2=0 IMR5.XPR2=0 IMR5.RME3=0 IMR5.RPF3=0 IMR5.XPR3=0 Unmask interrupts for HDLC processor requests. RTR4.0 = 1 TTR4.0 = 1 TSEO = 00H Select time slot 24 for HDLC data reception and transmission. Even and odd frames are used for HDLC reception and transmission. Select all bits of selected time slot (channel 1). Select all bits of selected time slot (channel 2). Select all bits of selected time slot (channel 3). Select time slot 1 for HDLC channel 2. Select time slot 2 for HDLC channel 3. TSBS1 = FFH TSBS2= FFH TSBS3= FFH TSS2= 01H TSS3= 02H Table 57 Initialization of the CAS-BR Controller (T1/J1) FMR5.EIBR = 1 Enable CAS-BR Mode Send CAS-BR information stored in XS(12:1) IMR1.CASE = 0 IMR0.RSC = 0 Enable interrupts which indicate the access to the XS(12:1) CASBR registers and any data change in RS(12:1) Note: After the device initialization a software reset should be executed by setting of bits CMDR.XRES/RRES. Data Sheet 200 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes 8 Signaling Controller Operating Modes The three HDLC controllers can be programmed to operate in various modes, which are different in the treatment of the HDLC frame in receive direction. Thus, the receive data flow and the address recognition features can be performed in a very flexible way, to satisfy almost any practical requirements. There are 4 different operating modes which can be set via the mode registers (MODE, MODE2 and MODE3). If not mentioned otherwise, all functions described for HDLC channel 1 apply to channel 2 and 3 as well. 8.1 HDLC Mode All frames with valid addresses are forwarded directly via the RFIFO to the system memory. Depending on the selected address mode, the FALC56 can perform a 1- or 2-byte address recognition (MODE.MDS0). If a 2-byte address field is selected, the high address byte is compared to the fixed value FEH or FCH (group address) as well as with two individually programmable values in RAH1 and RAH2 registers. According to the ISDN LAPD protocol, bit 1 of the high byte address is interpreted as command/response bit (C/R) and is excluded from the address comparison. Similarly, two compare values can be programmed in special registers (RAL1, RAL2) for the low address byte. A valid address is recognized in case the high and low byte of the address field correspond to one of the compare values. Thus, the FALC56 can be called (addressed) with 6 different address combinations. HDLC frames with address fields that do not match any of the address combinations, are ignored by the FALC56. In case of a 1-byte address, RAL1 and RAL2 are used as compare registers. The HDLC control field, data in the I-field and an additional status byte are temporarily stored in the RFIFO. Additional information can also be read from a special register (RSIS). As defined by the HDLC protocol, the FALC56 performs the zero bit insertion/deletion (bit stuffing) in the transmit/receive data stream automatically. That means, it is guaranteed that at least one “0” will appear after 5 consecutive “1”s. 8.1.1 Non-Auto Mode (MODE.MDS(2:1) = 01; MODE2.MDS22..21=01; MODE3.MDS32..31=01) Characteristics: address recognition, flag- and CRC generation/check, bit stuffing All frames with valid addresses are forwarded directly via the RFIFO (RFIFO2, RFIFO3) to the system memory. Data Sheet 201 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes 8.1.2 Transparent Mode 1 (MODE.MDS(2:0) = 101; MODE2.MDS2(2:0)=101; MODE3.MDS3(2:0)=101) Characteristics: address recognition, flag- and CRC generation/check, bit stuffing Only the high byte of a 2-byte address field is compared to registers RAH(2:1). The whole frame excluding the first address byte is stored in RFIFO (RFIFO2, RFIFO3). 8.1.3 Transparent Mode 0 (MODE.MDS(2:0) = 100; MODE2.MDS2(2:0)=100; MODE3.MDS3(2:0)=100) Characteristics: flag- and CRC generation/check, bit stuffing No address recognition is performed and each frame is stored in the RFIFO (RFIFO2, RFIFO3). 8.1.4 SS7 Support SS7 protocol is supported for channel 1 only by means of several hardware features as described in Chapter 4.1.14.2 on page 74 and Chapter 5.1.14.2 on page 135. 8.1.5 Receive Data Flow The following figure gives an overview of the management of the received HDLC frames in the different operating modes. Data Sheet 202 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes FLAG ADDR CTRL DATA CRC FLAG MODE.MDS(2:0) 1) RAH1,2 RAL1,2 RFIFO 0 1 1 Non-Auto/16 2) 2) RSIS RAH1,2 1) X RFIFO 0 1 0 Non-Auto/8 2) RSIS 1) RAH1,2 RFIFO 1 0 1 Transparent 1 2) RSIS 1) RFIFO 1 0 0 Transparent 0 RSIS Description of Symbols: compared with register stored in FIFO or register In case of 8-bit address the control field starts here 1) CRC is optionally stored in RFIFO of HDLC channel 1, 2 or 3 if CCR2.RCRC = 1 (channel 1) CCR3.RCRC2 = 1 (channel 2) CCR4.RCRC3 = 1 (channel 3) 2) Address is optionally stored in RFIFO of HDLC channel 1, 2 or 3 if CCR2.RADD = 1 (channel 1) CCR3.RADD2 = 1 (channel 2) CCR4.RADD3 = 1 (channel 3) F0235 Figure 76 Data Sheet HDLC Receive Data Flow 203 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes 8.1.6 Transmit Data Flow The frames can be transmitted as shown below. FLAG ADDR CTRL ADDRESS CONTROL Transmit HDLC Frame (XHF) Ι CRC DATA FLAG CHECKRAM XFIFO ITD06456 Figure 77 HDLC Transmit Data Flow Transmitting a HDLC frame via register CMDR.XTF (or CMDR2.XTF2/CMDR3.XTF3 for channel 2/3), the address, the control fields and the data field have to be entered in the XFIFO (XFIFO2, XFIFO3). If CCR2.XCRC (or CCR3.XCRC2/CCR4.XCRC3 for channel 2/3) is set, the CRC checksum will not be generated internally. The checksum has to be provided via the transmit FIFO (XFIFO, XFIFO2, XFIFO3) as the last two bytes. The transmitted frame is closed automatically with a closing flag only. The FALC56 does not check whether the length of the frame, i.e. the number of bytes to be transmitted makes sense or not. 8.2 Extended Transparent Mode Characteristics: fully transparent In no HDLC mode, fully transparent data transmission/reception without HDLC framing is performed, i.e. without flag generation/recognition, CRC generation/check, or bit stuffing. This feature can be profitably used e.g. for: • Specific protocol variations • Transmission of a BOM frame (channel 1 only) • Test purposes Data transmission is always performed out of the XFIFO (XFIFO2, XFIFO3). In transparent mode, the receive data is shifted into the RFIFO (RFIFO2, RFIFO3). Note: If a 1-byte frame is sent in extended transparent mode, in addition to interrupt ISR1.XPR (transmit pool ready) the interrupt ISR1.XDU (transmit buffer underrun) is set and XFIFO is blocked. Data Sheet 204 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes 8.3 Signaling Controller Functions 8.3.1 Transparent Transmission and Reception When programmed in the extended transparent mode via the MODE registers (MODE.MDS(2:0) = 111, MODE2.MDS2(2:0)=111, MODE3.MDS3(2:0)=111), the FALC56 performs fully transparent data transmission and reception without HDLC framing, i.e. without • flag insertion and deletion • CRC generation and checking • Bit stuffing In order to enable fully transparent data transfer, bit MODE.HRAC (MODE2.HRAC2, MODE3.HRAC3) has to be set. Received data is always shifted into RFIFO (RFIFO2, RFIFO3). Data transmission is always performed out of XFIFO (XFIFO2, XFIFO3) by shifting the contents of XFIFO into the outgoing data stream directly. Transmission is initiated by setting CMDR.XTF (04H). A synchronization byte FFH is sent automatically before the first byte of the XFIFO is transmitted. Cyclic Transmission (fully transparent) If the extended transparent mode is selected, the FALC56 supports the continuous transmission of the contents of the transmit FIFOs. After having written 1 to 32 bytes to XFIFO (XFIFO2, XFIFO3), the command XREP&XTF (CMDR = 00100100 = 24H) forces the FALC56 to transmit the data stored in XFIFO to the remote end repeatedly. Note: The cyclic transmission continues until a reset command (CMDR.SRES) is issued or with resetting of CMDR.XREP, after which continuous “1”s are transmitted. During cyclic transmission the XREP-bit has to be set with every write operation to CMDR. The same handling applies to CMDR2 and CMDR3 for HDLC channels 2 an 3. 8.3.2 CRC on/off Features As an option in HDLC mode the internal handling of the received and transmitted CRC checksum can be influenced via control bits CCR2.RCRC and CCR2.XCRC (channel 2: CCR3.RCRC2, CCR3.XCRC2, channel 3: CCR4.RCRC3, CCR4.XCRC3). • Receive Direction The received CRC checksum is always assumed to be in the 2 last bytes of a frame (CRC-ITU), immediately preceding a closing flag. If CCR2.RCRC is set, the received CRC checksum is written to RFIFO where it precedes the frame status byte (contents of register RSIS). The received CRC checksum is additionally checked for correctness. If Data Sheet 205 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes HDLC mode is selected, the limits for “Valid Frame” check are modified (refer to description of bit RSIS.VFR). • Transmit Direction If CCR2.XCRC is set, the CRC checksum is not generated internally. The checksum has to be provided via the transmit FIFO (XFIFO) as the last two bytes. The transmitted frame is closed automatically by a closing flag only. The FALC56 does not check whether the length of the frame, i.e. the number of bytes to be transmitted is valid or not. 8.3.3 Receive Address Pushed to RFIFO The address field of received frames can be pushed to the receive FIFOs (first one or two bytes of a frame). This function is used together with extended address recognition. It is enabled by setting control bit CCR2.RADD (CCR3.RADD2, CCR4.RADD3). 8.3.4 HDLC Data Transmission In transmit direction 2 × 32 byte FIFO buffers are provided for each HDLC channel. After checking the XFIFO status by polling bit SIS.XFW (SIS2.XFW2, SIS3,XFW3) or after an interrupt ISR1.XPR (ISR5.XPR2, ISR5.XPR3, Transmit Pool Ready), up to 32 bytes can be entered by the CPU to the XFIFOs. The transmission of a frame can be started by issuing a XTF or XHF command via the command registers. If the transmit command does not include an end of message indication (CMDR.XME, CMDR3.XME2, CMDR4.XME3), the FALC56 will repeatedly request for the next data block by means of an XPR interrupt as soon as no more than 32 bytes are stored in the XFIFO, i.e. a 32-byte pool is accessible to the CPU. This process is repeated until the CPU indicates the end of message by XME command, after which frame transmission is finished correctly by appending the CRC and closing flag sequence. Consecutive frames can share a flag, or can be transmitted as back-toback frames, if service of the XFIFOs is fast enough. In case no more data is available in the XFIFOs prior to the arrival of XME, the transmission of the frame is terminated with an abort sequence and the CPU is notified by interrupt ISR1.XDU (ISR4.XDU2, ISR5.XDU3). The frame can be aborted by software using CMDR.SRES (CMDR3.SRES2, CMDR4.SRES3). The data transmission sequence, from the CPU’s point of view, is outlined in Figure 78. Data Sheet 206 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes START N XPR Interrupt, or XFW Bit in SIS Register = 1 Transmit Pool Ready ? Y Write Data (up to 32 bytes) to XFIFO Command XTF/XHF End of Message ? N Y Command XTF/XHF + XME END Figure 78 ITD08565 Interrupt Driven Data Transmission (flow diagram) The activities at both serial and CPU interface during frame transmission (supposed frame length = 70 bytes) shown in Figure 79. Transmit Frame (70 bytes) 32 System Interface 32 6 FALC R CPU Interface XPR WR XFIFO 32 bytes XHF WR XFIFO 32 bytes Command XHF XPR XHF + XME XPR WR XFIFO 6 bytes ALLS ITD10971 Figure 79 Data Sheet Interrupt Driven Transmission Example 207 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes 8.3.5 HDLC Data Reception 2×32 byte FIFO buffers are also provided in receive direction for each HDLC channel. There are different interrupt indications concerned with the reception of data: • RPF (RPF2, RPF3, receive pool full) interrupt, indicating that a 32-byte block of data can be read from RFIFO (RFIFO2, RFIFO3) and the received message is not yet complete. • RME (RME2, RME3, receive message end) interrupt, indicating that the reception of one message is completed. The following figure gives an example of a reception sequence, assuming that a “long” frame (66 bytes) followed by two short frames (6 bytes each) are received. System Interface Receive Frame 1 (66 bytes) RF2 RF3 2 6 6 32 32 FALC R RMC RPF RMC RME RMC RME RMC RD6 bytes RD Status RD6 bytes RD Status RD2 bytes RD RFIFO 32 bytes RD RFIFO 32 bytes RPF RD Status CPU Interface RMC RME ITD10972 Figure 80 8.3.6 Interrupt Driven Reception Sequence Example Sa-bit Access (E1) The FALC56 supports the Sa-bit signaling of time slot 0 of every other frame as follows: • Access via registers RSW/XSW • Access via registers RSA(8:4)/XSA(8:4) capable of storing the information for a complete multiframe • Access via the 64 byte deep receive/transmit FIFO of the integrated signaling controller (HDLC channel 1 only). This Sa-bit access gives the opportunity to transmit/ receive a transparent bit stream as well as HDLC frames where the signaling controller automatically processes the HDLC protocol. Enabling is done by setting of bit CCR1.EITS and resetting of registers TTR(4:1), RTR(4:1) and FMR1.ENSA. Data Sheet 208 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes Data written to the XFIFO will be transmitted subsequently in the Sa-bit positions defined by register XC0.SA8E to SA84E and the corresponding bits of TSWM.TSA(8:4). Any combination of Sa-bits can be selected. After the data has been sent out completely an “all ones” or Flags (CCR1.ITF) is transmitted. The continuous transmission of a transparent bit stream, which is stored in the XFIFO, can be enabled. With the setting of bit MODE.HRAC the received Sa-bits can be forwarded to the receive FIFO. The access to and from the FIFOs is supported by ISR0.RME/RPF and ISR1.XPR/ ALS. 8.3.7 Bit Oriented Message Mode (T1/J1) The FALC56 supports signaling and maintenance functions for T1/J1 primary rate Interfaces using the Extended Super Frame format. The HDLC channel 1 of the device supports the DL-channel protocol for ESF format according to T1.403-1989 ANSI or to AT&T TR54016 specification. The HDLC and Bit Oriented Message (BOM) -Receiver can be switched on/off independently. If the FALC56 is used for HDLC formats only, the BOM receiver has to be switched off. If HDLC and BOM receiver has been switched on (MODE.HRAC/BRAC), an automatic switching between HDLC and BOM mode is enabled. Storing of received DL-bit information in the RFIFO of the signaling controller and transmitting the XFIFO contents in the DL-bit positions is enabled by CCR1.EDLX/ EITS = 10. After hardware-reset (pin RES low) or software-reset (CMDR.RRES = 1) the FALC56 operates in HDLC mode. If eight or more consecutive ones are detected, the BOM mode is entered. Upon detection of a flag in the data stream, the FALC56 switches back to HDLC mode. Operating in BOM mode, the FALC56 is able to receive an HDLC frame immediately, i.e. without any preceding flags. In BOM mode, the following byte format is assumed (the left most bit is received first; 111111110xxxxxx0). The FALC56 uses the FFH byte for synchronization, the next byte is stored in RFIFO (first bit received: LSB) if it starts and ends with a “0”. Bytes starting and ending with a “1” are not stored. If there are no 8 consecutive ones detected within 32 bits, an interrupt is generated. However, byte sampling is not stopped. Data Sheet 209 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes Byte sampling in BOM Mode (T1/J1) a) 1111 1111 1111 0011 0100 1111 1111 0011 0100 1110 1111 0011 0100 1101 1111 sync not stored new sync 1.byte stored 1.corrupted sync 2.byte stored 2.corrupted sync corrupted sync b) 1111 1111 0111 0110 1101 1111 0111 0110 1111 1111 0111 0110 0111 1111 sync 1.byte stored 1.corrupted byte 2.byte stored 2.sync 3.byte stored 3.corrupted sync Three different BOM reception modes can be programmed (CCR1.BRM, CCR2.RBFE). 10 byte packets: CCR1.BRM = 0 After storing 10 bytes in RFIFO the receive status byte marking a BOM frame (RSIS.HFR) is added as the eleventh byte and an interrupt (ISR0.RME) is generated. The sampling of data bytes continues and interrupts are generated every 10 bytes until an HDLC flag is detected. Continuous reception: CCR1.BRM = 1 Interrupts are generated every 32 (16, 4, 2) bytes. After detecting an HDLC flag, byte sampling is stopped, the receive status byte is stored in RFIFO and an RME interrupt is generated. Reception with enabled BOM filter: CCR2.RBFE = 1 The BOM receiver will only accept BOM frames after detecting 7 out of 10 equal BOM pattern. The BOM pattern is stored in the RFIFO adding a receive status byte, marking a BOM frame (RSIS.HFR) and generating an interrupt status ISR0.RME. The current state of the BOM receiver is indicated in register SIS.IVB. When the valid BOM pattern disappears an interrupt ISR0.BIV is generated. The user can switch between these modes at any time. Byte sampling can be stopped by deactivating the BOM receiver (MODE.BRAC). In this case the receive status byte is added, an interrupt is generated and HDLC mode is entered. Whether the FALC56 operates in HDLC or BOM mode are checked by reading the signaling status register (SIS.BOM). Data Sheet 210 2002-08-27 FALC56 V1.2 PEB 2256 Signaling Controller Operating Modes 8.3.8 Data Link Access in ESF/F72 Format (T1/J1) The FALC56 supports the DL-channel protocol using the ESF or F72 (SLC96) format as follows (HDLC channel 1 only): • Sampling of DL-bits is done on a multiframe basis and stored in the registers RDL(3:1). A receive multiframe begin interrupt is provided to read the received data DL-bits. The contents of registers XDL(3:1) is subsequently sent out on the transmit multiframe basis if it is enabled via FMR1.EDL. A transmit multiframe begin interrupt requests for writing new information to the DL-bit registers. • If enabled via CCR1.EDLX/EITS = 10, the DL-bit information is stored in the receive FIFO of the signaling controller. The DL-bits stored in the XFIFO are inserted into the outgoing data stream. If CCR1.EDLX is cleared, a HDLC frame or a transparent frame can be sent or received via the RFIFO/XFIFO. Data Sheet 211 2002-08-27 FALC56 V1.2 PEB 2256 Register Description Due to the different device function is E1 and T1/J1 mode, several registers and register bits have dedicated functions according to the selected operation mode. To maintain easy readability this chapter is divided into separate E1 and T1/J1 sections. Please choose the correct description according to your application (E1 or T1/J1). Data Sheet 212 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 9 E1 Registers 9.1 E1 Control Register Addresses Table 58 E1 Control Register Address Arrangement Address Register Type Comment Page 00 XFIFO W Transmit FIFO 217 01 XFIFO W Transmit FIFO 217 02 CMDR W Command Register 217 03 MODE R/W Mode Register 219 04 RAH1 R/W Receive Address High 1 220 05 RAH2 R/W Receive Address High 2 220 06 RAL1 R/W Receive Address Low 1 220 07 RAL2 R/W Receive Address Low 2 220 08 IPC R/W Interrupt Port Configuration 221 09 CCR1 R/W Common Configuration Register 1 221 0A CCR2 R/W Common Configuration Register 2 224 0C RTR1 R/W Receive Time Slot Register 1 225 0D RTR2 R/W Receive Time Slot Register 2 225 0E RTR3 R/W Receive Time Slot Register 3 225 0F RTR4 R/W Receive Time Slot Register 4 225 10 TTR1 R/W Transmit Time Slot Register 1 226 11 TTR2 R/W Transmit Time Slot Register 2 226 12 TTR3 R/W Transmit Time Slot Register 3 226 13 TTR4 R/W Transmit Time Slot Register 4 226 14 IMR0 R/W Interrupt Mask Register 0 227 15 IMR1 R/W Interrupt Mask Register 1 227 16 IMR2 R/W Interrupt Mask Register 2 227 17 IMR3 R/W Interrupt Mask Register 3 227 18 IMR4 R/W Interrupt Mask Register 4 227 19 IMR5 R/W Interrupt Mask Register 5 227 1B IERR R/W Single Bit Error Insertion Register 227 1C FMR0 R/W Framer Mode Register 0 Data Sheet 213 228 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Table 58 E1 Control Register Address Arrangement (cont’d) Address Register Type Comment Page 1D FMR1 R/W Framer Mode Register 1 230 1E FMR2 R/W Framer Mode Register 2 232 1F LOOP R/W Channel Loop-Back 233 20 XSW R/W Transmit Service Word 234 21 XSP R/W Transmit Spare Bits 235 22 XC0 R/W Transmit Control 0 236 23 XC1 R/W Transmit Control 1 237 24 RC0 R/W Receive Control 0 238 25 RC1 R/W Receive Control 1 239 26 XPM0 R/W Transmit Pulse Mask 0 241 27 XPM1 R/W Transmit Pulse Mask 1 241 28 XPM2 R/W Transmit Pulse Mask 2 241 29 TSWM R/W Transparent Service Word Mask 242 2B IDLE R/W Idle Channel Code 243 2C XSA4 R/W Transmit Sa4-Bit Register 244 2D XSA5 R/W Transmit Sa5-Bit Register 244 2E XSA6 R/W Transmit Sa6-Bit Register 244 2F XSA7 R/W Transmit Sa7-Bit Register 244 30 XSA8 R/W Transmit Sa8-Bit Register 244 31 FMR3 R/W Framer Mode Register 3 245 32 ICB1 R/W Idle Channel Register 1 246 33 ICB2 R/W Idle Channel Register 2 246 34 ICB3 R/W Idle Channel Register 3 246 35 ICB4 R/W Idle Channel Register 4 246 36 LIM0 R/W Line Interface Mode 0 247 37 LIM1 R/W Line Interface Mode 1 248 38 PCD R/W Pulse Count Detection 249 39 PCR R/W Pulse Count Recovery 250 3A LIM2 R/W Line Interface Mode 2 250 3B LCR1 R/W Loop Code Register 1 251 Data Sheet 214 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Table 58 E1 Control Register Address Arrangement (cont’d) Address Register Type Comment Page 3C LCR2 R/W Loop Code Register 2 253 3D LCR3 R/W Loop Code Register 3 253 3E SIC1 R/W System Interface Control 1 254 3F SIC2 R/W System Interface Control 2 255 40 SIC3 R/W System Interface Control 3 256 44 CMR1 R/W Clock Mode Register 1 258 45 CMR2 R/W Clock Mode Register 2 259 46 GCR R/W Global Configuration Register 261 47 ESM R/W Errored Second Mask 262 60 DEC W Disable Error Counter 262 70 XS1 W Transmit CAS Register 1 263 71 XS2 W Transmit CAS Register 2 263 72 XS3 W Transmit CAS Register 3 263 73 XS4 W Transmit CAS Register 4 263 74 XS5 W Transmit CAS Register 5 263 75 XS6 W Transmit CAS Register 6 263 76 XS7 W Transmit CAS Register 7 263 77 XS8 W Transmit CAS Register 8 263 78 XS9 W Transmit CAS Register 9 263 79 XS10 W Transmit CAS Register 10 263 7A XS11 W Transmit CAS Register 11 263 7B XS12 W Transmit CAS Register 12 263 7C XS13 W Transmit CAS Register 13 263 7D XS14 W Transmit CAS Register 14 263 7E XS15 W Transmit CAS Register 15 263 7F XS16 W Transmit CAS Register 16 263 80 PC1 R/W Port Configuration 1 264 81 PC2 R/W Port Configuration 2 264 82 PC3 R/W Port Configuration 3 264 83 PC4 R/W Port Configuration 4 264 Data Sheet 215 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Table 58 E1 Control Register Address Arrangement (cont’d) Address Register Type Comment Page 84 PC5 R/W Port Configuration 5 266 85 GPC1 R/W Global Port Configuration 1 267 86 PC6 R/W Port Configuration 6 268 87 CMDR2 W Command Register 2 269 88 CMDR3 W Command Register 3 269 89 CMDR4 W Command Register 4 270 8B CCR3 R/W Common Control Register 3 271 8C CCR4 R/W Common Control Register 4 273 8D CCR5 R/W Common Control Register 5 274 8E MODE2 R/W Mode Register 2 275 8F MODE3 R/W Mode Register 3 276 92 GCM1 R/W Global Counter Mode 1 277 93 GCM2 R/W Global Counter Mode 2 277 94 GCM3 R/W Global Counter Mode 3 278 95 GCM4 R/W Global Counter Mode 4 278 96 GCM5 R/W Global Counter Mode 5 279 97 GCM6 R/W Global Counter Mode 6 279 9C XFIFO2 W Transmit FIFO 2 281 9D XFIFO2 W Transmit FIFO 2 281 9E XFIFO3 W Transmit FIFO 3 281 9F XFIFO3 W Transmit FIFO 3 281 A0 TSEO R/W Time Slot Even/Odd Select 281 A1 TSBS1 R/W Time Slot Bit Select 1 282 A2 TSBS2 R/W Time Slot Bit Select 2 283 A3 TSBS3 R/W Time Slot Bit Select 3 283 A4 TSS2 R/W Time Slot Select 2 284 A5 TSS3 R/W Time Slot Select 3 284 A8 TPC0 R/W Test Pattern Control Register 0 285 After reset all control registers except the XFIFO and XS(16:1) are initialized to defined values. Unused bits have to be cleared (logical "0"). Data Sheet 216 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 9.2 Detailed Description of E1 Control Registers Transmit FIFO - HDLC Channel 1 (Write) 7 0 XFIFO XF7 XF0 (00) XFIFO XF15 XF8 (01) Writing data to XFIFO of HDLC channel 1 can be done in 8-bit (byte) or 16-bit (word) access. The LSB is transmitted first. Up to 32 bytes/16 words of transmit data can be written to the XFIFO following a XPR interrupt. Command Register (Write) Value after reset: 00H 7 CMDR RMC RMC 0 RRES XREP XRES XHF XTF XME SRES (02) Receive Message Complete - HDLC Channel 1 Confirmation from CPU to FALC56 that the current frame or data block has been fetched following a RPF or RME interrupt, thus the occupied space in the RFIFO can be released. If RMC is given while RFIFO is already cleared, the next incoming data block is cleared instantly, although interrupts are generated. RRES Receiver Reset The receive line interface except the clock and data recovery unit (DPLL), the receive framer, the one-second timer and the receive signaling controller are reset. However the contents of the control registers is not deleted. XREP Transmission Repeat - HDLC Channel 1 If XREP is set together with XTF (write 24H to CMDR), the FALC56 repeatedly transmits the contents of the XFIFO (1 to 32 bytes) without HDLC framing fully transparently, i.e. without flag, CRC. The cyclic transmission is stopped with a SRES command or by resetting XREP. Note:During cyclic transmission the XREP-bit has to be set with every write operation to CMDR. Data Sheet 217 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XRES Transmitter Reset The transmit framer and transmit line interface excluding the system clock generator and the pulse shaper are reset. However the contents of the control registers is not deleted. XHF Transmit HDLC Frame - HDLC Channel 1 After having written up to 32 bytes to the XFIFO, this command initiates the transmission of a HDLC frame. XTF Transmit Transparent Frame - HDLC Channel 1 Initiates the transmission of a transparent frame without HDLC framing. XME Transmit Message End - HDLC Channel 1 Indicates that the data block written last to the transmit FIFO completes the current frame. The FALC56 can terminate the transmission operation properly by appending the CRC and the closing flag sequence to the data. SRES Signaling Transmitter Reset - HDLC Channel 1 The transmitter of the signaling controller is reset. XFIFO is cleared of any data and an abort sequence (seven 1's) followed by interframe time fill is transmitted. In response to SRES a XPR interrupt is generated. This command can be used by the CPU to abort a frame currently in transmission. Note: The maximum time between writing to the CMDR register and the execution of the command takes 2.5 periods of the current system data rate. Therefore, if the CPU operates with a very high clock rate in comparison with the FALC56's clock, it is recommended that bit SIS.CEC should be checked before writing to the CMDR register to avoid any loss of commands. Note: If SCLKX is used to clock the transmission path, commands to the HDLC transmitter should only be sent while this clock is available. If SCLKX is missing, the command register is blocked after an HDLC command is given. Data Sheet 218 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Mode Register (Read/Write) Value after reset: 00H 7 MODE MDS(2:0) MDS2 0 MDS1 MDS0 HRAC DIV (03) Mode Select - HDLC Channel 1 The operating mode of the HDLC controller is selected. 000 = Reserved 001 = Signaling System 7 (SS7) support1) 010 = One-byte address comparison mode (RAL1,2) 011 = Two-byte address comparison mode (RAH1,2 and RAL1,2) 100 = No address comparison 101 = One-byte address comparison mode (RAH1,2) 110 = Reserved 111 = No HDLC framing mode HRAC Receiver Active - HDLC Channel 1 Switches the HDLC receiver to operational or inoperational state. DIV 0= Receiver inactive 1= Receiver active Data Inversion - HDLC Channel 1 Setting this bit inverts the internal generated HDLC channel 1 data stream. 1) 0= Normal operation, HDLC data stream not inverted 1= HDLC data stream inverted CCR2.RADD must be set, if SS7 mode is selected Data Sheet 219 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Address Byte High Register 1 (Read/Write) Value after reset: FDH 7 0 RAH1 0 (04) In operating modes that provide high byte address recognition, the high byte of the received address is compared to the individually programmable values in RAH1 and RAH2. The address registers are used by all HDLC channels in common. RAH1 Value of the First Individual High Address Byte Bit 1 (C/R-bit) is excluded from address comparison. Receive Address Byte High Register 2 (Read/Write) Value after reset: FFH 7 0 RAH2 (05) RAH2 Value of Second Individual High Address Byte Receive Address Byte Low Register 1 (Read/Write) Value after reset: FFH 7 0 RAL1 (06) RAL1 Value of First Individual Low Address Byte Receive Address Byte Low Register 2 (Read/Write) Value after reset: FFH 7 0 RAL2 RAL2 Data Sheet (07) Value of the second individually programmable low address byte. 220 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Interrupt Port Configuration (Read/Write) Value after reset: 00H 7 0 IPC SSYF IC1 IC0 (08) Note: Unused bits have to be cleared. SSYF Select SYNC Frequency Only applicable in master mode (LIM0.MAS = 1) and bit CMR2.DCF is cleared. 0= 1= IC0, IC1 Reference clock on port SYNC is 2.048 MHz Reference clock on port SYNC is 8 kHz Interrupt Port Configuration These bits define the function of the interrupt output stage (pin INT): IC1 IC0 Function X 0 1 0 1 1 Open drain output Push/pull output, active low Push/pull output, active high Common Configuration Register 1 (Read/Write) Value after reset: 00H 7 CCR1 XTS16RA 0 XTS16RA CASM EITS ITF XMFA RFT1 RFT0 (09) Send Remote Alarm in Time Slot 16 Sending of remote alarm in time slot 16 towards remote end by setting bit "Y" in the CAS multiframe alignment word. If XS registers are used for CAS (instead of XSIG), bit XS1.2 ("Y") is logically ored with XTS16RA. If XSIG is used for CAS, Y-data received on XSIG is logically ored with XTS16RA. CASM Data Sheet 0= No remote alarm insertion 1= Remote alarm insertion CAS Synchronization Mode 221 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Determines the synchronization mode of the channel associated signaling multiframe alignment. EITS ITF 0= Synchronization is done in accordance to ITU-T G. 732 1= Synchronization is established when two consecutively correct multiframe alignment pattern are found. Enable Internal Time Slot 0 to 31 Signaling 0= Internal signaling in time slots 0 to 31 defined by registers RTR(4:1) or TTR(4:1) is disabled. 1= Internal signaling in time slots 0 to 31 defined by registers RTR(4:1) or TTR(4:1) is enabled. Interframe Time Fill Determines the idle (= no data to be sent) state of the transmit data coming from the signaling controller. XMFA 0= Continuous logical "1" is output 1= Continuous flag sequences are output ("01111110" bit patterns) Transmit Multiframe Aligned Determines the synchronization between the framer and the corresponding signaling controller. 0= The contents of the XFIFO is transmitted without multiframe alignment. 1= The contents of the XFIFO is transmitted multiframe aligned. The first byte in XFIFO is transmitted in the first time slot selected by TTR(4:1) and so on. After reception of a complete multiframe in the time slot mode (RTR(4:1)) an ISR0.RME interrupt is generated, if no HDLC mode is enabled In Sa-bit access mode XMFA is not valid. Note: During the transmission of the XFIFO content, the SYPX or XMFS interval time should not be changed, otherwise the XFIFO data has to be retransmitted. Data Sheet 222 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RFT(1:0) RFIFO Threshold Level - HDLC Channel 1 The size of the accessible part of RFIFO can be determined by programming these bits. The number of valid bytes after a RPF interrupt is given in the following table: RFT1 RFT0 Size of Accessible Part of RFIFO 0 0 1 1 0 1 0 1 32 bytes (reset value) 16 bytes 4 bytes 2 bytes The value of RFT1, 0 can be changed dynamically. – If reception is not running or – after the current data block has been read, but before the command CMDR.RMC is issued (interrupt controlled data transfer). Note: It is seen that changing the value of RFT1, 0 is possible even during the reception of one frame. The total length of the received frame can be always read directly in RBCL, RBCH after a RPF interrupt, except when the threshold is increased during reception of that frame. The real length can then be inferred by noting which bit positions in RBCL are reset by a RMC command (see table below): Data Sheet RFT1 RFT0 Bit Positions in RBCL Reset by a CMDR.RMC Command 0 0 1 1 0 1 0 1 RBC(4:0) RBC(3:0) RBC(1:0) RBC0 223 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Common Configuration Register 2 (Read/Write) Value after reset: 00H 7 CCR2 0 RADD RCRC XCRC (0A) Note: Unused bits have to be cleared. RADD Receive Address Pushed to RFIFO - HDLC Channel 1 If this bit is set, the received HDLC address information (1 or 2 bytes, depending on the address mode selected by MODE.MDS0) is pushed to RFIFO. This function is applicable in non-auto mode and transparent mode 1. RADD must be set, if SS7 mode is selected. RCRC Receive CRC on/off - HDLC Channel 1 Only applicable in non-auto mode. If this bit is set, the received CRC checksum is written to RFIFO (CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in the received frame, is followed by the status information byte (contents of register RSIS). The received CRC checksum is additionally checked for correctness. If non-auto mode is selected, the limits for “valid frame” check are modified (refer to RSIS.VFR). XCRC Transmit CRC on/off - HDLC Channel 1 If this bit is set, the CRC checksum is not generated internally. It has to be written to the transmit FIFO as the last two bytes. The transmitted frame is closed automatically with a closing flag. Note: The FALC56 does not check whether the length of the frame, i.e. the number of bytes to be transmitted makes sense or not. Data Sheet 224 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Time Slot Register 1 to 4 (Read/Write) Value after reset: 00H, 00H, 00H, 00H 7 0 RTR1 TS0 TS1 TS2 TS3 TS4 TS5 TS6 TS7 (0C) RTR2 TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15 (0D) RTR3 TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23 (0E) RTR4 TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 (0F) TS(31:0) Time Slot These bits define the received time slots on the system highway port RDO to be extracted to RFIFO and marked. Additionally these registers control the RSIGM marker which can be forced high during the corresponding time slots independently of bit CCR1.EITS. A one in the RTR(4:1) bits samples the corresponding time slots and send their data to the RFIFO of the signaling controller if bit CCR1.EITS is set. Assignments: TS0 →Time slot 0 ... TS31 → Time slot 31 0 =The corresponding time slot is not extracted and stored into the RFIFO. 1= Data Sheet The contents of the selected time slot is stored in the RFIFO. Although the idle time slots can be selected. This function is activated, if bit CCR1.EITS is set. The corresponding time slot is forced high on marker pin RSIGM. 225 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit Time Slot Register 1 to 4 (Read/Write) Value after reset: 00H, 00H, 00H, 00H 7 0 TTR1 TS0 TS1 TS2 TS3 TS4 TS5 TS6 TS7 (10) TTR2 TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15 (11) TTR3 TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23 (12) TTR4 TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 (13) TS(31:0) Time Slot These bits define the transmit time slots on the system highway to be inserted. Additionally these registers control the XSIGM marker which can be forced high during the corresponding time slots independently of bit CCR1.EITS. A one in the TTR(4:1) bits inserts the corresponding time slot sourced by the XFIFO in the data received on pin XDI, if bit CCR1.EITS is set. If SIC3.TTRF is set and CCR1.EITS is cleared insertion of data received on port XSIG is controlled by this registers. Assignments: TS0 →Time slot 0 ... TS31 → Time slot 31 Data Sheet 0= The selected time slot is not inserted into the outgoing data stream. 1= The contents of the selected time slot is inserted into the outgoing data stream from XFIFO. This function is active only if bit CCR1.EITS is set. The corresponding time slot is forced high on marker pin XSIGM. 226 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Interrupt Mask Register 0 to 5 (Read/Write) Value after reset: FFH, FFH, FFH, FFH, FFH 7 0 IMR0 RME RFS T8MS RMB CASC CRC4 SA6SC RPF (14) IMR1 LLBSC RDO ALLS XDU XMB SUEX XLSC XPR (15) IMR2 FAR LFA MFAR T400MS AIS LOS RAR RA (16) IMR3 ES SEC LMFA16 AIS16 RA16 RSN RSP (17) IMR4 XSP XSN RME2 RFS2 RDO2 ALLS2 XDU2 RPF2 (18) IMR5 XPR2 XPR3 RME3 RFS3 RDO3 ALLS3 XDU3 RPF3 (19) IMR(5:0) Interrupt Mask Register Each interrupt source can generate an interrupt signal on port INT (characteristics of the output stage are defined by register IPC). A “1” in a bit position of IMR(5:0) sets the mask active for the interrupt status in ISR(5:0). Masked interrupt statuses neither generate a signal on INT, nor are they visible in register GIS. Moreover, they are - not displayed in the interrupt status register if bit GCR.VIS is cleared - displayed in the interrupt status register if bit GCR.VIS is set Note: After reset, all interrupts are disabled. Single Bit Defect Insertion Register (Read/Write) Value after reset: 00H IERR IFASE IMFE ICRCE ICASE IPE IBV (1B) After setting the corresponding bit, the selected defect is inserted into the transmit data stream at the next possible position. After defect insertion is completed, the bit is reset automatically. IFASE Insert single FAS defect IMFE Insert single multiframe defect ICRCE Insert single CRC defect ICASE Insert single CAS defect IPE Insert single PRBS defect Data Sheet 227 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers IBV Insert bipolar violation Note:Except for CRC defects, CRC checksum calculation is done after defect insertion. Framer Mode Register 0 (Read/Write) Value after reset: 00H 7 FMR0 XC(1:0) XC1 0 XC0 RC1 RC0 EXZE ALM FRS SIM (1C) Transmit Code Serial line code for the transmitter, independent of the receiver. 00 = NRZ (optical interface) 01 = CMI (1T2B+HDB3), (optical interface) 10 = AMI (ternary or digital dual-rail interface) 11 = HDB3 Code (ternary or digital dual-rail interface) After changing XC(1:0), a transmitter software reset is required (CMDR.XRES = 1). RC(1:0) Receive Code Serial line code for the receiver, independent of the transmitter. 00 = NRZ (optical interface) 01 = CMI (1T2B+HDB3), (optical interface) 10 = AMI (ternary or digital dual-rail interface) 11 = HDB3 Code (ternary or digital dual-rail interface) After changing RC(1:0), a receiver software reset is required (CMDR.RRES = 1). EXZE Extended HDB3 Error Detection Selects error detection mode. ALM 0= Only double violations are detected. 1= Extended code violation detection: 0000 strings are detected additionally. Incrementing of the code violation counter CVC is done after receiving four zeros. Errors are indicated by FRS1.EXZD = 1. Alarm Mode Selects the AIS alarm detection mode. Data Sheet 228 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers FRS 0= The AIS alarm is detected according to ETS300233. Detection: An AIS alarm is detected if the incoming data stream contains less than 3 zeros within a period of 512 bits and a loss of frame alignment is indicated. Recovery: The alarm is cleared if 3 or more zeros within 512 bits are detected or the FAS word is found. 1= The AIS alarm is detected according to ITU-T G.775 Detection: An AIS alarm is detected if the incoming data stream contains less than 3 zeros in each doubleframe period of two consecutive doubleframe periods (1024 bits). Recovery: The alarm is cleared if 3 or more zeros are detected within two consecutive doubleframe periods. Force Resynchronization A transition from low to high initiates a resynchronization procedure of the pulse frame and the CRC-multiframe (if enabled by bit FMR2.RFS1) starting directly after the old framing candidate. SIM Alarm Simulation 0= Normal operation. 1= Initiates internal error simulation of AIS, loss-of-signal, loss of synchronization, remote alarm, slip, framing errors, CRC errors, and code violations. The error counters FEC, CVC, CEC1 are incremented. SIM has to be held stable at high or low level for at least one receive clock period before changing it again. Data Sheet 229 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Framer Mode Register 1 (Read/Write) Value after reset: 00H 7 FMR1 MFCS MFCS 0 AFR ENSA PMOD XFS ECM SSD0 XAIS (1D) is selected Multiframe Force Resynchronization Only valid if CRC (FMR2.RFS(1:0) = 10). multiframe format A transition from low to high initiates the resynchronization procedure for CRC-multiframe alignment without influencing doubleframe synchronous state. In case, “Automatic Force Resynchronization” (FMR1.AFR) is enabled and multiframe alignment cannot be regained, a new search of doubleframe (and CRC multiframe) is automatically initiated. AFR Automatic Force Resynchronization Only valid if CRC (FMR2.RFS(1:0) = 10). multiframe format is selected If this bit is set, a search of doubleframe alignment is automatically initiated if two multiframe patterns with a distance of n × 2 ms have not been found within a time interval of 8 ms after doubleframe alignment has been regained or command FMR1.MFCS has been issued. ENSA Enable Sa-Bit Access through Register XSA4-8 Only applicable if FMR1.XFS is set. PMOD 0= Normal operation. The Sa-bit information is taken from bits XSW.XY(4:0) and written to bits RSW.RY(4:0). 1= Sa-bit register access. The Sa-bit information is taken from the registers XSA(8:4). In addition, the received information is written to registers RSA(8:4). Transmitting of the contents of registers XSA(8:4) is disabled if one of time slot 0 transparent modes is enabled (XSP.TT0 or TSWM.SA(8:4)). PCM Mode For E1 application this bit must be set low. Switching from E1 to T1 or vice versa the device needs up to 20 µs to settle up to the internal clocking. 0= Data Sheet PCM 30 or E1 mode. 230 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 1= XFS PCM 24 or T1/J1 mode (see RC0.SJR for T1/J1 selection). Transmit Framing Select Selection of the transmit framing format can be done independently of the receive framing format. ECM 0= Doubleframe format enabled. 1= CRC4-multiframe format enabled. Error Counter Mode The function of the error counters is determined by this bit. SSD0 0= Before reading an error counter the corresponding bit in the Disable Error Counter register (DEC) has to be set. In 8 bit access the low byte of the error counter should always be read before the high byte. The error counters are reset with the rising edge of the corresponding bits in the DEC register. 1= Every second the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Reading the error counter during updating should be avoided (do not access an error counter within 1 µs after the one-second interrupt occurs). Select System Data Rate 0 FMR1.SSD0 and SIC1.SSD1 define the data rate on the system highway. Programming is done with SSD1/SSD0 in the following table. 00 = 2.048 Mbit/s 01 = 4.096 Mbit/s 10 = 8.192 Mbit/s 11 = 16.384 Mbit/s XAIS Transmit AIS Towards Remote End Sends AIS on ports XL1, XL2, XOID towards the remote end. The outgoing data stream which can be looped back through the local loop to the system interface is not affected. Data Sheet 231 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Framer Mode Register 2 (Read/Write) Value after reset: 00H 7 FMR2 RFS(1:0) RFS1 0 RFS0 RTM DAIS SAIS PLB AXRA ALMF (1E) Receive Framing Select 00 = Doubleframe format 01 = Doubleframe format 10 = CRC4 Multiframe format 11 = CRC4 Multiframe format with modified CRC4 Multiframe alignment algorithm (Interworking according to ITU-T G.706 Annex B). Setting of FMR3.EXTIW changes the reaction after the 400 ms time-out. RTM Receive Transparent Mode Setting this bit disconnects control of the internal elastic store from the receiver. The elastic store is now in a “free running” mode without any possibility to actualize the time slot assignment to a new frame position in case of resynchronization of the receiver. This function can be used together with the “disable AIS to system interface” feature (FMR2.DAIS) to realize undisturbed transparent reception. This bit should be enabled in case of unframed data reception mode. DAIS SAIS Disable AIS to System Interface 0= AIS is automatically inserted into the data stream to RDO if FALC56 is in asynchronous state. 1= Automatic AIS insertion is disabled. Furthermore, AIS insertion can be initiated by programming bit FMR2.SAIS. Send AIS Towards System Interface Sends AIS on output RDO towards system interface. This function is not influenced by bit FMR2.DAIS. PLB Data Sheet Payload Loop-Back 0= Normal operation. Payload loop is disabled. 1= The payload loop-back loops the data stream from the receiver section back to transmitter section. Looped data is output on pin RDO. Data received on port XDI, XSIG, SYPX and XMFS is ignored. With XSP.TT0 = 1 time slot 0 is also looped back. If XSP.TT0 = 0 time slot 0 is generated internally. AIS is sent 232 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers immediately on port RDO by setting the FMR2.SAIS bit. It is recommended to write the actual value of XC1 into this register once again, because a write access to register XC1 sets the read/write pointer of the transmit elastic buffer into its optimal position to ensure a maximum wander compensation (the write operation forces a slip). AXRA Automatic Transmit Remote Alarm ALMF 0= Normal operation 1= The remote alarm bit is set automatically in the outgoing data stream if the receiver is in asynchronous state (FRS0.LFA bit is set). In synchronous state the remote alarm bit is reset. Additionally in multiframe format FMR2.RFS1 = 1 and FMR3.EXTIW = 1 and the 400 ms time-out has elapsed, the remote alarm bit is active in the outgoing data stream. In multiframe synchronous state the outgoing remote alarm bit is cleared. Automatic Loss of Multiframe 0= Normal operation 1= The receiver searches a new basic- and multiframing if more than 914 CRC errors have been detected in a time interval of one second. The internal 914 CRC error counter is reset if the multiframe synchronization is found. Incrementing the counter is only enabled in the multiframe synchronous state. Channel Loop-Back (Read/Write) Value after reset: 00H 7 0 LOOP ECLB CLA(4:0) ECLB CLA4 CLA3 CLA2 CLA1 CLA0 (1F) Enable Channel Loop-Back 0= Disables the channel loop-back. 1= Enables the channel loop-back selected by this register. Channel Address For Loop-Back CLA = 0 to 31 selects the channel. During looped back the contents of the assigned outgoing channel on ports XL1/XDOP/XOID and XL2/XDON is equal to the idle channel code programmed at register IDLE. Data Sheet 233 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit Service Word Pulseframe (Read/Write) Value after reset: 00H 7 XSW XSIS XSIS 0 XTM XRA XY0 XY1 XY2 XY3 XY4 (20) Spare Bit For International Use First bit of the service word. Only significant in doubleframe format. If not used, this bit should be fixed to "1". If one of the time slot 0 transparent modes is enabled (bit XSP.TT0, or TSWM.TSIS), bit XSW.XSIS is ignored. XTM XRA XY(4:0) Transmit Transparent Mode 0= Ports SYPX/XMFS define the frame/multiframe begin on the transmit system highway. The transmitter is usually synchronized on this externally sourced frame boundary and generates the FAS-bits according to this framing. Any change of the transmit time slot assignment subsequently produces a change of the FAS-bit positions. 1= Disconnects the control of the transmit system interface from the transmitter. The transmitter is now in a free running mode without any possibility to actualize the multiframe position. The framing (FAS-bits) generated by the transmitter is not “disturbed” (in case of changing the transmit time slot assignment) by the transmit system highway unless register XC1 is written. Useful in loop-timed applications. For proper operation the transmit elastic buffer (2 frames, SIC1.XBS(1:0) = 10) has to be enabled. Transmit Remote Alarm 0= Normal operation. 1= Sends remote alarm towards remote end by setting bit 3 of the service word. If time slot 0 transparent mode is enabled by bit XSP.TT0 or TSWM.TRA bit is set, bit XSW.XRA is ignored. Spare Bits For National Use (Y-Bits, Sn-Bits, Sa-Bits) These bits are inserted in the service word of every other pulseframe if Sa-bit register access is disabled (FMR1.ENSA = 0). If not used, they should be fixed to “1”. If one of the time slot 0 transparent modes is enabled (bit XSP.TT0 or TSWM.TSA(8:4)), bits XSW.XY(4:0) are ignored. Data Sheet 234 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit Spare Bits (Read/Write) Value after reset: 00H 7 0 XSP CASEN CASEN Channel Associated Signaling Enable TT0 EBP AXS TT0 EBP AXS XSIF XS13 XS15 (21) 0= Normal operation. 1= A one in this bit position causes the transmitter to send the CAS information stored in the XS(16:1) registers or serial CAS data in the corresponding time slots. Time slot 0 Transparent Mode 0= Normal operation. 1= All information for time slot 0 on port XDI is inserted in the outgoing pulseframe. All internal information of the FALC56 (framing, CRC, Sa/Si-bit signaling, remote alarm) is ignored. This function is mainly useful for system test applications (test loops). Priority sequence of transparent modes: XSP.TTO > TSWM. E-Bit Polarity 0= In the basic- and multiframe asynchronous state the E-bit is cleared. 1= In the basic- and multiframe asynchronous state the E-bit is set. If automatic transmission of submultiframe status is enabled by setting bit XSP.AXS and the receiver has lost synchronization, the E-bit with the programmed polarity is inserted automatically in Si-bit position of every outgoing CRC multiframe (under the condition that time slot 0 transparent mode and transparent Si bit in service word are both disabled). Automatic Transmission of Submultiframe Status Only applicable to CRC multiframe. Data Sheet 0= Normal operation. 1= Information of submultiframe status bits RSP.SI1 and RSP.SI2 are inserted automatically in Si -bit positions of the outgoing CRC multiframe (RSP.SI1 → Si -bit of frame 13; RSP.SI2 → Si-bit of frame 15). Contents of XSP.XS13 and XSP.XS15 is 235 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers ignored. If one of the time slot 0 transparent modes XSP.TT0 or TSWM.TSIS is enabled, bit XSP.AXS has no function. XSIF Transmit Spare Bit For International Use (FAS Word) First bit in the FAS word. Only significant in doubleframe format. If not used, this bit should be fixed to "1". If one of the time slot 0 transparent modes is enabled (bits XSP.TT0, or TSWM.TSIF), bit XSP.XSIF is ignored. XS13 Transmit Spare Bit (Frame 13, CRC-Multiframe) First bit in the service word of frame 13 for international use. Only significant in CRC-multiframe format. If not used, this bit should be fixed to "1". The information of XSP.XS13 is shifted into internal transmission buffer with beginning of the next following transmitted CRC multiframe. If automatic transmission of submultiframe status is enabled by bit XSP.AXS, or, if one of the time slot 0 transparent modes XSP.TT0 or TSWM.TSIS is enabled, bit XSP.XS13 is ignored. XS15 Transmit Spare Bit (Frame 15, CRC-Multiframe) First bit in the service word of frame 15 for international use. Only significant in CRC-multiframe format. If not used, this bit should be fixed to "1". The information of XSP.XS15 is shifted into the internal transmission buffer with beginning of the next following transmitted CRC multiframe. If automatic transmission of submultiframe status is enabled by bit XSP.AXS, or, if one of the time slot 0 transparent modes XSP.TT0 or TSWM.TSIF is enabled, bit XSP.XS15 is ignored. Transmit Control 0 (Read/Write) Value after reset: 00H 7 XC0 SA(8:4)E Data Sheet SA8E 0 SA7E SA6E SA5E SA4E XCO10 XCO9 XCO8 (22) Sa-Bit Signaling Enable 0= Standard operation. 1= Setting this bit makes it possible to send/receive a LAPD protocol in any combination of the Sa-bit positions in the outgoing/incoming data stream. The on chip signaling controller has to be configured in the HDLC/LAPD mode. In transmit 236 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers direction together with these bits the TSWM.TSA(8:4) bits must be set to enable transmission to the remote end transparently through the FALC56. XCO(10:8) Transmit Offset Initial value loaded into the transmit bit counter at the trigger edge of SCLKX when the synchronous pulse on port SYPX/XMFS is active Refer to register XC1. Transmit Control 1 (Read/Write) Value after reset: 9CH XC1 7 0 XCO7 XCO0 (23) A write access to this address resets the transmit elastic buffer to its basic starting position. Therefore, updating the value should only be done when the FALC56 is initialized or when the buffer should be centered. As a consequence a transmit slip will occur. XCO(7:0) Transmit Offset Calculation of delay time T (SCLKX cycles) depends on the value X of the “Transmit Offset” register XC(1:0): 0 ≤ T ≤ 4: X = 4 - T 5 ≤ T ≤ maximum delay: X = 256 × SC/SD - T + 4) with maximum delay = (256 × SC/SD) -1 with SC = system clock defined by SIC1.SSC(1:0) with SD = 2.048 MHz Delay time T = time between beginning of time slot 0 (bit 0, channel phase 0) at XDI/XSIG and the initial edge of SCLKX after SYPX/ XMFS goes active. See page 111 for further description. Data Sheet 237 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Control 0 (Read/Write) Value after reset: 00H 7 RC0 SWD ASY4 CRCI SWD 0 ASY4 CRCI XCRCI RDIS RCO10 RCO9 RCO8 (24) Service Word Condition Disable 0= Standard operation. Three or four consecutive incorrect service words (depending on bit RC0.ASY4) causes loss of synchronization. 1= Errors in service words have no influence when in synchronous state. However, they are used for the resynchronization procedure. Select Loss of Sync Condition 0= Standard operation. Three consecutive incorrect FAS words or three consecutive incorrect service words causes loss of synchronization. 1= Four consecutive incorrect FAS words or four consecutive incorrect service words causes loss of synchronization. The service word condition is disabled by bit RC0.SWD. Automatic CRC4 Bit Inversion If set, all CRC bits of one outgoing submultiframe are inverted in case a CRC error is flagged for the previous received submultiframe. This function is logically ored with RC0.XCRCI. XCRCI Transmit CRC4 Bit Inversion If set, the CRC bits in the outgoing data stream are inverted before transmission. This function is logically ored with RC0.CRCI. RDIS Receive Data Input Sense Digital interface, dual-rail: 0= Inputs RDIP/RDIN are active low 1= Inputs RDIP/RDIN are active high Digital Interface, CMI: Data Sheet 0= Input ROID is active high 1= Input ROID is active low 238 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RCO(10:8) Receive Offset/Receive Frame Marker Offset Depending on the RP(A to D) pin function different offsets can be programmed. The SYPR and the RFM pin function cannot be selected in parallel. Receive Offset (PC(4:1).RPC(2:0) = 000) Initial value loaded into the receive bit counter at the trigger edge of SCLKR when the synchronous pulse on port SYPR is active. Calculation of delay time T (SCLKR cycles) depends on the value X of the receive offset register RC(1:0). For programing refer to register RC1. Receive Frame Marker Offset (PC(4:1).RPC(2:0) = 001B) Offset programming of the receive frame marker which is output on port SYPR. The receive frame marker can be activated during any bit position of the current frame. Calculation of the value X of the receive offset register RC(1:0) depends on the bit position which should be marked and SCLKR. Refer to register RC1. Receive Control 1 (Read/Write) Value after reset: 9CH RC1 RCO(7:0) 7 0 RCO7 RCO0 (25) Receive Offset/Receive Frame Marker Offset Depending on the RP(A to D) pin function different offsets can be programmed. The SYPR and the RFM pin function cannot be selected in parallel. Receive Offset (PC(4:1).RPC(2:0) = 000) Initial value loaded into the receive bit counter at the trigger edge of SCLKR when the synchronous pulse on port SYPR is active. Calculation of delay time T (SCLKR cycles) depends on the value X of the receive offset register RC(1:0): 0 ≤ T ≤ 4: X = 4 - T 5 ≤ T ≤ maximum delay:X = 2052 - T with maximum delay = (256×SC/SD) -1 with SC = system clock defined by SIC1.SSC(1:0) with SD = system data rate Data Sheet 239 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Delay time T = time between beginning of time slot 0 at RDO and the initial edge of SCLKR after SYPR goes active. See page 106 for further description. Receive Frame Marker Offset (PC(4:1).RPC(2:0) = 001B) Offset programming of the receive frame marker which is output on multifunction port RFM. The receive frame marker can be activated during any bit position of the entire frame and depends on the selected system clock rate. Calculation of the value X of the receive offset register RC(1:0) depends on the bit position which should be marked at marker position MP: 0 ≤ MP ≤ 2045:X = MP + 2 2046 ≤ MP ≤ 2047: X = MP - 2046 e.g: 2.048 MHz: MP = 0 to 255; up to 16.384 MHz: MP = 0 to 2047 Data Sheet 240 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit Pulse Mask (Read/Write) Value after reset: 7BH, 03H, 40H 7 0 XPM0 XP12 XP11 XP10 XP04 XP03 XP02 XP01 XP00 (26) XPM1 XP30 XP24 XP23 XP22 XP21 XP20 XP14 XP13 (27) XPM2 0 XLT DAXLT XP34 XP33 XP32 XP31 (28) The transmit pulse shape which is defined in ITU-T G.703 is output on pins XL1 and XL2. The level of the pulse shape can be programmed by registers XPM(2:0) to create a custom waveform. In order to get an optimized pulse shape for the external transformers each pulse shape is internally divided into four sub pulse shapes. In each sub pulse shape a programmed 5 bit value defines the level of the analog voltage on pins XL1/2. Together four 5 bit values have to be programmed to form one complete transmit pulse shape. The four 5 bit values are sent in the following sequence: XP04 to 00: XP14 to 10: XP24 to 20: XP34 to 30: First pulse shape level Second pulse shape level Third pulse shape level Fourth pulse shape level Changing the LSB of each subpulse in registers XPM(2:0) changes the amplitude of the differential voltage on XL1/2 by approximately 80 mV. Example:120 Ω interface and wired as shown in Figure 50 on page 155. XP04 to 00: XP14 to 10: XP24 to 20: XP34 to 30: 1BH or 27 decimal 1BH or 27 decimal 00H 00H Programming values for XPM(2:0): 00H, 03H,7BH XLT Data Sheet Transmit Line Tristate 0= Normal operation 1= Transmit line XL1/XL2 or XDOP/XDON are switched into highimpedance state. If this bit is set the transmit line monitor status information is frozen (default value after hardware reset). 241 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers DAXLT Disable Automatic Tristating of XL1/2 0= Normal operation. If a short is detected on pins XL1/2 the transmit line monitor sets the XL1/2 outputs into a highimpedance state. 1= If a short is detected on XL1/2 pins automatic setting these pins into a high-impedance (by the XL-monitor) state is disabled. Transparent Service Word Mask (Read/Write) Value after reset: 00H 7 TSWM TSIS 0 TSIF TRA TSA4 TSA5 TSA6 TSWM(7:0) Transparent Service Word Mask TSIS Transparent Si-Bit in Service Word TSIF TRA Data Sheet TSA7 TSA8 (29) 0= The Si-Bit is generated internally. 1= The Si-Bit in the service word is taken from port XDI and transparently passed through the FALC56 without any changes. The internal information of the FALC56 (register XSW) is ignored. Transparent Si-Bit in FAS Word 0= The Si-Bit is generated internally. 1= The Si-Bit in the FAS word is taken from port XDI and routed transparently through the FALC56 without any changes. The internal information of the FALC56 (register XSW) is ignored. Transparent Remote Alarm 0= The remote alarm bit is generated internally. 1= The A-Bit is taken from port XDI and routed transparently through the FALC56 without any changes. The internal information of the FALC56 (register XSW) is ignored. 242 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers TSA(8:4) Transparent Sa(8:4)-Bit 0= The Sa(8:4)-bits are generated internally. 1= The Sa(8:4)-bits are taken from port XDI or from the internal signaling controller if enabled and transparently passed through the FALC56 without any changes. The internal information of the FALC56 (registers XSW and XSA(8:4)) is ignored. Idle Channel Code Register (Read/Write) Value after reset: 00H IDLE IDL(7:0) 7 0 IDL7 IDL0 (2B) Idle Channel Code If channel loop-back is enabled by programming LOOP.ECLB = 1, the contents of the assigned outgoing channel on ports XL1/XL2 or XDOP/XDON is set equal to the idle channel code selected by this register. Additionally, the specified pattern overwrites the contents of all channels selected by the idle channel registers ICB(4:1). IDL7 is transmitted first. Data Sheet 243 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit Sa(8:4) Register (Read/Write) Value after reset: 00H, 00H, 00H, 00H, 00H 7 0 XSA4 XS47 XS46 XS45 XS44 XS43 XS42 XS41 XS40 (2C) XSA5 XS57 XS56 XS55 XS54 XS53 XS52 XS51 XS50 (2D) XSA6 XS67 XS66 XS65 XS64 XS63 XS62 XS61 XS60 (2E) XSA7 XS77 XS76 XS75 XS74 XS73 XS72 XS71 XS70 (2F) XSA8 XS87 XS86 XS85 XS84 XS83 XS82 XS81 XS80 (30) XSA(8:4) Transmit Sa-Bit Data The Sa-bit register access is enabled by setting bit FMR1.ENSA = 1. With the transmit multiframe begin an interrupt ISR1.XMB is generated and the contents of these registers XSA(8:4) is copied into a shadow register. The contents is subsequently sent out in the service words of the next outgoing CRC multiframe (or doubleframes) if none of the time slot 0 transparent modes is enabled. XS40 is sent out in bit position 4 in frame 1, XS47 in frame 15. The transmit multiframe begin interrupt XMB request that these registers should be serviced. If requests for new information are ignored, current contents is repeated. Data Sheet 244 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Framer Mode Register 3 (Read/Write) Value after reset: 00H 7 0 FMR3 XLD XLU CMI XLD XLU CMI SA6SY EXTIW (31) Transmit LLB Down Code 0= Normal operation. 1= A one in this bit position causes the transmitter to replace normal transmit data with the LLB down (deactivate) Code continuously until this bit is reset. The LLB down Code is optionally overwritten by the time slot 0 depending on bit LCR1.FLLB. Transmit LLB UP Code 0= Normal operation. 1= A one in this bit position causes the transmitter to replace normal transmit data with the LLB UP Code continuously until this bit is reset. The LLB UP Code is overwritten by the time slot 0 depending on bit LCR1.FLLB. For proper operation bit FMR3.XLD must be cleared. Select CMI Precoding Only valid if CMI code (FMR0.XC(1:0) = 01) is selected. This bit defines the CMI precoding and influences transmit and receive data. 0= CMI with HDB3 precoding 1= CMI without HDB3 precoding Note: Before local loop is selected, HDB3 precoding has to be disabled. SA6SY Receive Sa6-Access Synchronous Mode Only valid if multiframe format (FMR2.RFS(1:0) = 1x) is selected. Data Sheet 0= The detection of the predefined Sa6-bit pattern (refer to chapter Sa6-bit detection according to ETS 300233) is done independently of the multiframe synchronous state. 1= The detection of the Sa6-bit pattern is done synchronously to the multiframe. 245 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers EXTIW Extended CRC4 to Non-CRC4 Interworking Only valid in multiframe format. This bit selects the reaction of the synchronizer after the 400 ms time-out has been elapsed and starts transmitting a remote alarm if FMR2.AXRA is set. 0= The CRC4 to Non CRC4 interworking is done as described in ITU-T G. 706 Annex B. 1= The interworking is done according to ITU-T G. 706 with the exception that the synchronizer still searches the multiframing even if the 400 ms timer is expired. Switching into doubleframe format is disabled. If FMR2.AXRA is set the remote alarm bit is active in the outgoing data stream until the multiframe is found. Idle Channel Register (Read/Write) Value after reset: 00H, 00H, 00H, 00H 7 0 ICB1 IC0 IC1 IC2 IC3 IC4 IC5 IC6 IC7 (32) ICB2 IC8 IC9 IC10 IC11 IC12 IC13 IC14 IC15 (33) ICB3 IC16 IC17 IC18 IC19 IC20 IC21 IC22 IC23 (34) ICB4 IC24 IC25 IC26 IC27 IC28 IC29 IC30 IC31 (35) IC(31:0) Idle Channel Selection Bits These bits define the channels (time slots) of the outgoing PCM frame to be altered. Assignments: IC0 → Time slot 0 IC1 → Time slot 1 ... IC31 → Time slot 31 0= Normal operation. 1= Idle channel mode. The contents of the selected time slot is overwritten by the idle channel code defined by register IDLE. Note: Although time slot 0 can be selected by bit IC0, its contents is only altered if the transparent mode is selected (XSP.TT0). Data Sheet 246 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Line Interface Mode 0 (Read/Write) Value after reset: 00H 7 LIM0 XFB XFB 0 XDOS EQON RLM LL MAS (36) Transmit Full Bauded Mode Only applicable for dual-rail mode (bit LIM1.DRS = 1). 0= Output signals XDOP/XDON are half bauded. 1= Output signals XDOP/XDON are full bauded. Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to be cleared. XDOS Transmit Data Out Sense 0= Output signals XDOP/XDON are active low. Output XOID is active high (normal operation). 1= Output signals XDOP/XDON are active high. Output XOID is active low. Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to be cleared. The transmit frame marker XFM is independent of this bit. EQON RLM LL Data Sheet Receive Equalizer On 0= -10 dB receiver, short-haul mode 1= -43 dB receiver, long-haul mode Receive Line Monitoring 0= Normal receiver mode 1= Receiver mode for receive line monitoring; the receiver sensitivity is increased to detect resistively attenuated signals of -20 dB (short-haul mode only) Local Loop 0= Normal operation 1= Local loop active. The local loop-back mode disconnects the receive lines RL1/RL2 or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data provided by system interface are routed through the analog receiver back to the system interface. The unipolar bit stream is transmitted 247 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers undisturbedly on the line. Receiver and transmitter coding must be identical. Operates in analog and digital line interface mode. In analog line interface mode data is transferred through the complete analog receiver. MAS Master Mode 0= Slave mode 1= Master mode on. Setting this bit the DCO-R circuitry is frequency synchronized to the clock (2.048 MHz or 8 kHz, see IPC.SSYF) supplied by SYNC. If this pin is connected to VSS or VDD (or left open and pulled up to VDD internally) the DCO-R circuitry is centered and no receive jitter attenuation is performed (only if 2.048 MHz clock is selected by resetting bit IPC.SSYF). The generated clocks are stable. Line Interface Mode 1 (Read/Write) Value after reset: 00H 7 LIM1 CLOS = RIL(2:0) CLOS 0 RIL2 RIL1 RIL0 JATT RL DRS (37) Clear data in case of LOS 0= Normal receiver mode, receive data stream is transferred normally in long-haul mode 1= In long-haul mode received data is cleared (driven to low level), as soon as LOS is detected Receive Input Threshold Only valid if analog line interface is selected (LIM1.DRS = 0). “No signal” is declared if the voltage between pins RL1 and RL2 drops below the limits programmed by bits RIL(2:0) and the received data stream has no transition for a period defined in the PCD register. The threshold where “no signal” is declared is programmable by the RIL(2:0) bits depending on bit LIM0.EQON. Note: LIM1.RIL(2:0) must be programmed before LIM0.EQON = 1 is set. See DC characteristics for detail. Data Sheet 248 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers JATT, RL Remote Loop Transmit Jitter Attenuator 00 = Normal operation. The remote loop transmit jitter attenuator is disabled. Transmit data bypasses the remote loop jitter attenuator buffer. 01 = Remote loop active without remote loop transmit jitter attenuator enabled. Transmit data bypasses the remote loop jitter attenuator buffer. 10 = not defined 11 = Remote loop and remote loop jitter attenuator active. Received data from pins RL1/2 or RDIP/N or ROID is sent "jitter-free" on ports XL1/2 or XDOP/N or XOID. The de-jittered clock is generated by the DCO-X circuitry. Note: JATT is only used to define the jitter attenuation during remote loop operation. Jitter attenuation during normal operation is not affected. DRS Dual-Rail Select 0= The ternary interface is selected. Multifunction ports RL1/2 and XL1/2 become analog in/outputs. 1= The digital dual-rail interface is selected. Received data is latched on multifunction ports RDIP/RDIN while transmit data is output on pins XDOP/XDON. Pulse Count Detection Register (Read/Write) Value after reset: 00H PCD PCD(7:0) 7 0 PCD7 PCD0 (38) Pulse Count Detection A LOS alarm is detected if the incoming data stream has no transitions for a programmable number T consecutive pulse positions. The number T is programmable by the PCD register and can be calculated as follows: T = 16 × (N+1); with 0 ≤ N ≤ 255. The maximum time is: 256 × 16 × 488 ns = 2 ms. Every detected pulse resets the internal pulse counter. The counter is clocked with the receive clock RCLK. Data Sheet 249 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Pulse Count Recovery (Read/Write) Value after reset: 00H PCR 7 0 PCR7 PCR0 PCR(7:0) (39) Pulse Count Recovery A LOS alarm is cleared if a pulse-density is detected in the received bit stream. The number of pulses M which must occur in the predefined PCD time interval is programmable by the PCR register and can be calculated as follows: M = N+1; with 0 ≤ N ≤ 255. The time interval starts with the first detected pulse transition. With every received pulse a counter is incremented and the actual counter is compared to the contents of PCR register. If the pulse number is higher or equal to the PCR value the LOS alarm is reset otherwise the alarm stays active. In this case the next detected pulse transition starts a new time interval. Line Interface Mode 2 (Read/Write) Value after reset: 20H 7 LIM2 SLT(1:0) 0 SLT1 SLT0 SCF ELT (3A) Receive Slicer Threshold 00 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 55% of the peak amplitude. 01 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 67% of the peak amplitude (recommended in some T1/J1 applications). 10 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 50% of the peak amplitude (default, recommended in E1 mode). 11 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 45% of the peak amplitude. Data Sheet 250 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers SCF Select Corner Frequency of DCO-R Setting this bit reduces the corner frequency of the DCO-R circuit by the factor of ten to 0.2 Hz. Note: Reducing the corner frequency of the DCO-R circuitry increases the synchronization time before the frequencies are synchronized. ELT Enable Loop-Timed 0= Normal operation 1= Transmit clock is generated from the clock supplied by MCLK which is synchronized to the extracted receive route clock. In this configuration the transmit elastic buffer has to be enabled. Refer to register XSW.XTM. For correct operation of loop timed the remote loop (bit LIM1.RL = 0) must be inactive and bit CMR1.DXSS must be cleared. Loop Code Register 1 (Read/Write) Value after reset: 00H 7 LCR1 EPRM XPRBS EPRM 0 XPRBS LDC1 LDC0 LAC1 LAC0 FLLB LLBP (3B) Enable Pseudo-Random Binary Sequence Monitor 0= Pseudo-Random Binary Sequence (PRBS) monitor is disabled. 1= PRBS is enabled. Setting this bit enables incrementing the CEC2 error counter with each detected PRBS bit error. With any change of state of the PRBS internal synchronization status an interrupt ISR1.LLBSC is generated. The current status of the PRBS synchronizer is indicated by bit RSP.LLBAD. Transmit Pseudo-Random Binary Sequence A one in this bit position enables transmission of a pseudo-random binary sequence to the remote end. Depending on bit LLBP the PRBS is generated according to 215-1 or 220-1 with a maximum-14-zero restriction (ITU-T O. 151). Data Sheet 251 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers LDC(1:0) Length Deactivate (Down) Code These bits defines the length of the LLB deactivate code which is programmable in register LCR2. 00 = Length: 5 bit 01 = Length: 6 bit, 2 bit, 3 bit 10 = Length: 7 bit 11 = Length: 8 bit, 2 bit, 4bit LAC(1:0) Length Activate (Up) Code These bits defines the length of the LLB activate code which is programmable in register LCR3. 00 = Length: 5 bit 01 = Length: 6 bit, 2 bit, 3 bit 10 = Length: 7 bit 11 = Length: 8 bit, 2 bit, 4 bit FLLB Framed Line Loop-Back/Invert PRBS Depending on bit LCR1.XPRBS this bit enables different functions: LCR1.XPRBS = 0: 0= The line loop-back code is transmitted including framing bits. LLB code overwrites the FS/DL-bits. 1= The line loop-back code is transmitted unframed. LLB code does not overwrite the FS/DL-bits. Invert PRBS LCR1.XPRBS = 1: LLBP 0= The generated PRBS is transmitted not inverted. 1= The PRBS is transmitted inverted. Line Loop-Back Pattern LCR1.XPRBS = 0 0= Fixed line loop-back code according to ANSI T1. 403. 1= Enable user-programmable line loop-back code by register LCR2/3. LCR1.XPRBS = 1 or LCR1.EPRM = 1 Data Sheet 0= 215 -1 1= 220 -1 252 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Loop Code Register 2 (Read/Write) Value after reset: 00H LCR2 7 0 LDC7 LDC0 LDC(7:0) (3C) Line Loop-Back Deactivate Code If enabled by bit FMR3.XLD = 1 the LLB deactivate code automatically repeats until the LLB generator is stopped. Transmit data is overwritten by the LLB code. LDC0 is transmitted last. For correct operations bit LCR1.XPRBS has to cleared. If LCR2 is changed while the previous deactivate code has been detected and is still received, bit RSP.LLBDD will stay active until the incoming signal changes or a receiver reset is initiated (CMDR.RRES = 1). Loop Code Register 3 (Read/Write) Value after reset: 00H LCR3 LAC(7:0) 7 0 LAC7 LAC0 (3D) Line Loop-Back Activate Code If enabled by bit FMR3.XLU = 1 the LLB activate code automatically repeats until the LLB generator is stopped. Transmit data is overwritten by the LLB code. LAC0 is transmitted last. For correct operations bit LCR1.XPRBS has to cleared. If LCR3 is changed while the previous activate code has been detected and is still received, bit RSP.LLBAD will stay active until the incoming signal changes or a receiver reset is initiated (CMDR.RRES = 1). Data Sheet 253 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers System Interface Control 1 (Read/Write) Value after reset: 00H 7 SIC1 SSC(1:0) SSC1 0 SSD1 RBS1 RBS0 SSC0 BIM XBS1 XBS0 (3E) Select System Clock SIC1.SSC(1:0) define the clocking rate on the system highway. 00 = 2.048 MHz 01 = 4.096 MHz 10 = 8.192 MHz 11 = 16.384 MHz SSD1 Select System Data Rate 1 SIC1.SSD1 and FMR1.SSD0 define the data rate on the system highway. Programming SSD1/SSD0 and corresponding data rate is shown below. 00 = 2.048 Mbit/s 01 = 4.096 Mbit/s 10 = 8.192 Mbit/s 11 = 16.384 Mbit/s RBS(1:0) Receive Buffer Size 00 = Buffer size: 2 frames 01 = Buffer size: 1 frame 10 = Buffer size: 96 bits 11 = bypass of receive elastic store BIM XBS(1:0) Bit Interleaved Mode 0= Byte interleaved mode 1= Bit interleaved mode Transmit Buffer Size 00 = Bypass of transmit elastic store 01 = Buffer size: 1 frame 10 = Buffer size: 2 frames 11 = Buffer size: 96 bits Data Sheet 254 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers System Interface Control 2 (Read/Write) Value after reset: 00H 7 SIC2 FFS FFS 0 SSF CRB SICS2 SICS1 SICS0 (3F) Force Freeze Signaling Setting this bit disables updating of the receive signaling buffer and current signaling information is frozen. After resetting this bit and receiving a complete superframe updating of the signaling buffer is started again. The freeze signaling status can also be automatically generated by detecting the loss-of-signal alarm or a loss of CAS frame alignment or a receive slip (only if external register access on pin RSIG is enabled). This automatic freeze signaling function is logically ored with this bit. The current internal freeze signaling status is output on pin RPA to RPD using pin function FREEZE which is selected by PC(4:1).RPC(2:0) = 110. Additionally, this status is also available in register SIS.SFS. SSF Serial Signaling Format Only applicable if pin function RSIG/XSIG and SIC3.TTRF = 0 is selected. CRB 0= Bits 1 to 4 in all time slots except time slots 0 and16 are cleared. 1= Bits 1 to 4 in all time slots except time slots 0 and16 are set high. Center Receive Elastic Buffer Only applicable if the time slot assigner is disabled (PC(4:1).RPC(2:0) = 001B), no external or internal synchronous pulse receive is generated. A transition from low to high forces a receive slip and the read- pointer of the receive elastic buffer is centered. The delay through the buffer is set to one half of the current buffer size. It should be hold high for at least two 2.048 MHz periods before it is cleared. SICS(2:0) System Interface Channel Select Only applicable if the system clock rate is greater than 2.048 MHz. Received data is transmitted on pin RDO/RSIG or received on XDI/ XSIG with the selected system data rate. If the data rate is greater than 2.048 Mbit/s the data is output or sampled in half, a quarter or Data Sheet 255 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers one eighth of the time slot. Data is not repeated. The time while data is active during a 8 × 488 ns time slot is called a channel phase. RDO/ RSIG are cleared (driven to low level) while XDI/XSIG are ignored for the remaining time of the 8 × 488 ns or for the remaining channel phases. The channel phases are selectable with these bits. 000 = Data active in channel phase 1, valid if system data rate is 16⁄8⁄4 Mbit/s 001 = Data active in channel phase 2, valid if system data rate is 16⁄8⁄4 Mbit/s 010 =Data active in channel phase 3, valid if data rate is 16/8 Mbit/s 011 = Data active in channel phase 4, valid if data rate is 16/8 Mbit/s 100 = Data active in channel phase 5, valid if data rate is 16 Mbit/s 101 = Data active in channel phase 6, valid if data rate is 16 Mbit/s 110 = Data active in channel phase 7, valid if data rate is 16 Mbit/s 111 = Data active in channel phase 8, valid if data rate is 16 Mbit/s System Interface Control 3 (Read/Write) Value after reset: 00H 7 SIC3 0 CASMF CASMF Data Sheet RESX RESR TTRF DAF (40) CAS Multiframe Begin Marker 0= The time slot 0 multiframe begin is asserted on pin RP(A to D)/ pin function RMFB. 1= The time slot 16 CAS multiframe begin is asserted on pin RP(A to D)/pin function RMFB. 256 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RESX Rising Edge Synchronous Pulse Transmit Depending on this bit all transmit system interface data and marker are clocked or sampled with the selected active edge. CMR2.IXSC = 0: 0 latched with the first falling edge of the selected PCM highway clock. 1 latched with the first rising edge of the selected PCM highway clock. CMR2.IXSC = 1: value of RESX bit has no impact on the selected edge of the PCM highway clock but value of RESR bit is used as RESX. Example: If RESR = 0, the rising edge of PCM highway clock is the selected one for sampling data on XDI and vice versa. RESR Rising Edge Synchronous Pulse Receive Depending on this bit all receive system interface data and marker are clocked with the selected active edge. 0= Latched with the first falling edge of the selected PCM highway clock. 1= Latched with the first rising edge of the selected PCM highway clock. Note: If bit CMR2.IRSP is set, the behavior of signal RFM (if used) is inverse (1 = falling edge, 0 = rising edge) TTRF TTR Register Function (Fractional E1 Access) Setting this bit the function of the TTR(4:1) registers is changed. A one in each TTR register forces the XSIGM marker high for the corresponding time slot and controls sampling of the time slots provided on pin XSIG. XSIG is selected by PC(4:1).XPC(3:0). DAF Data Sheet Disable Automatic Freeze 0= Signaling is automatically frozen if one of the following alarms occurred: Loss-Of-Signal (FRS0.LOS), Loss of CAS Frame Alignment (FRS1.TS16LFA), or receive slips (ISR3.RSP/N). 1= Automatic freezing of signaling data is disabled. Updating of the signaling buffer is also done if one of the above described alarm conditions is active. However, updating of the signaling buffer is stopped if SIC2.FFS is set. Significant only if the serial signaling access is enabled. 257 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Clock Mode Register 1 (Read/Write) Value after reset: 00H 7 0 CMR1 RS(1:0) RS1 RS0 DCS STF DXJA DXSS (44) Select RCLK Source These bits select the source of RCLK. 00 = Clock recovered from the line through the DPLL drives RCLK 01 = Clock recovered from the line through the DPLL drives RCLK and in case of an active LOS alarm RCLK pin is set high. 10 = Clock recovered from the line is de-jittered by DCO-R to drive a 2.048 MHz clock on RCLK. 11 = Clock recovered from the line is de-jittered by DCO-R to drive a 8.192 MHz clock on RCLK. DCS Disable Clock-Switching In Slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the recovered route clock. In case of loss-of-signal LOS the DCO-R switches automatically to the clock sourced by port SYNC. Setting this bit automatic switching from RCLK to SYNC is disabled. STF Select TCLK Frequency Only applicable if the pin function TCLK port XP(A to D) is selected by PC(4:1).XPC(3:0) = 0011B. Data on XL1/2 (XDOP/N / XOID) are clocked with TCLK. DXJA 0= 2.048 MHz 1= 8.192 MHz Disable Internal Transmit Jitter Attenuation Setting this bit disables the transmit jitter attenuation. Reading the data out of the transmit elastic buffer and transmitting on XL1/2 (XDOP/N/XOID) is done with the clock provided on pin TCLK. In transmit elastic buffer bypass mode the transmit clock is taken from SCLKX, independent of this bit. Data Sheet 258 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers DXSS DCO-X Synchronization Clock Source 0= The DCO-X circuitry synchronizes to the internal reference clock which is sourced by SCLKX/R or RCLK. Since there are many reference clock opportunities the following internal prioritizing in descending order from left to right is realized: LIM1.RL > CMR1.DXSS > LIM2.ELT > current working clock of transmit system interface. If one of these bits is set the corresponding reference clock is taken. 1= DCO-X synchronizes to an external reference clock provided on pin XP(A to D) pin function TCLK, if no remote loop is active. TCLK is selected by PC(4:1).XPC(3:0) = 0011B. Clock Mode Register 2 (Read/Write) Value after reset: 00H 7 0 CMR2 DCOXC DCF Data Sheet DCOXC DCF IRSP IRSC IXSP IXSC (45) DCO-X Center-Frequency Enable 0= The center function of the DCO-X circuitry is disabled. 1= The center function of the DCO-X circuitry is enabled. DCO-X centers to 2.048 MHz related to the master clock reference (MCLK), if reference clock (e.g. SCLKX) is missing. DCO-R Center- Frequency Disabled 0= The DCO-R circuitry is frequency centered - in master mode if no 2.048 MHz reference clock on pin SYNC is provided or - in slave mode if a loss-of-signal occurs in combination with no 2.048 MHz clock on pin SYNC or - a gapped clock is provided on pin RCLKI and this clock is inactive or stopped. 1= The center function of the DCO-R circuitry is disabled. The generated clock (DCO-R) is frequency frozen in that moment when no clock is available on pin SYNC or pin RCLKI. The DCO-R circuitry starts synchronization as soon as a clock appears on pins SYNC or RCLKI. 259 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers IRSP Internal Receive System Frame Sync Pulse 0= The frame sync pulse for the receive system interface is sourced by SYPR (if SYPR is applied). If SYPR is not applied, the frame sync pulse is derived from RDO output signal internally free running). The use of IRSP = 0 is recommended. 1= The frame sync pulse for the receive system interface is internally sourced by the DCO-R circuitry. This internally generated frame sync signal can be output (active low) on multifunction ports RP(A to D) (RPC(2:0) = 001B). Note: This is the only exception where the use of RFM and SYPR is allowed at the same time. Because only one set of offset registers (RC1/0) is available, programming is done by using the SYPR calculation formula in the same way as for the external SYPR pulse. Bit IRSC must be set for correct operation. IRSC IXSP IXSC Data Sheet Internal Receive System Clock 0= The working clock for the receive system interface is sourced by SCLKR or in receive elastic buffer bypass mode from the corresponding extracted receive clock RCLK. 1= The working clock for the receive system interface is sourced internally by DCO-R or in bypass mode by the extracted receive clock. SCLKR is ignored. Internal Transmit System Frame Sync Pulse 0= The frame sync pulse for the transmit system interface is sourced by SYPX. 1= The frame sync pulse for the transmit system interface is internally sourced by the DCO-R circuitry. Additionally, the external XMFS signal defines the transmit multiframe begin. XMFS is enabled or disabled by the multifunction port configuration. For correct operation bits CMR2.IXSC/IRSC must be set. SYPX is ignored. Internal Transmit System Clock 0= The working clock for the transmit system interface is sourced by SCLKX. 1= The working clock for the transmit system interface is sourced internally by the working clock of the receive system interface. SCLKX is ignored. 260 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Global Configuration Register (Read/Write) Value after reset: 00H 7 GCR VIS SCI SES ECMC PD VIS 0 SCI SES ECMC PD (46) Masked Interrupts Visible 0= Masked interrupt status bits are not visible in registers ISR(5:0). 1= Masked interrupt status bits are visible in ISR(5:0), but they are not visible in register GIS. Status Change Interrupt 0= Interrupts are generated either on activation or deactivation of the internal interrupt source. 1= The following interrupts are activated both on activation and deactivation of the internal interrupt source: ISR2.LOS, ISR2.AIS, ISR3.LMFA16 Select External Second Timer 0= Internal second timer selected 1= External second timer selected Error Counter Mode COFA 0= The Sa6-bit error indications are accumulated in the error counter CEC3L/H. 1= A Change of Frame or Multiframe Alignment COFA is detected since the last resynchronization. The events are accumulated in the error counter CEC3L.(1:0). Multiframe periods received in the asynchronous state are accumulated in the error counter CEC3L.7-2. An overflow of each counter is disabled. Power Down Switches between power-up and power-down mode. Data Sheet 0= Power up 1= Power down All outputs are driven inactive; multifunction ports are driven high by the weak internal pullup device. 261 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Errored Second Mask (Read/Write) Value after reset: FFH 7 ESM LFA ESM 0 FER CER AIS LOS CVE SLIP EBE (47) Errored Second Mask This register functions as an additional mask register for the interrupt status bit Errored Second (ISR3.ES). A "1" in a bit position of ESM deactivates the related second interrupt. Disable Error Counter (Write) Value after reset: 00H 7 DEC DRBD DRBD 0 DCEC3 DCEC2 DCEC1 DEBC DCVC DFEC (60) Disable Receive Buffer Delay This bit has to be set before reading the register RBD. It is reset automatically if RBD has been read. DCEC3 Disable CRC Error Counter 3 DCEC2 Disable CRC Error Counter 2 DCEC1 Disable CRC Error Counter DEBC Disable Errored Block Counter DCVC Disable Code Violation Counter DFEC Disable Framing Error Counter These bits are only valid if FMR1.ECM is cleared. They have to be set before reading the error counters. They are reset automatically if the corresponding error counter high byte has been read. With the rising edge of these bits the error counters are latched and then cleared. Note: Error counters and receive buffer delay can be read 1 µs after setting the according bit in bit DEC. Data Sheet 262 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit CAS Register (Write) Value after reset: not defined Table 59 Transmit CAS Registers (E1) 7 0 XS1 0 0 0 0 X Y X X (70) XS2 A1 B1 C1 D1 A16 B16 C16 D16 (71) XS3 A2 B2 C2 D2 A17 B17 C17 D17 (72) XS4 A3 B3 C3 D3 A18 B18 C18 D18 (73) XS5 A4 B4 C4 D4 A19 B19 C19 D19 (74) XS6 A5 B5 C5 D5 A20 B20 C20 D20 (75) XS7 A6 B6 C6 D6 A21 B21 C21 D21 (76) XS8 A7 B7 C7 D7 A22 B22 C22 D22 (77) XS9 A8 B8 C8 D8 A23 B23 C23 D23 (78) XS10 A9 B9 C9 D9 A24 B24 C24 D24 (79) XS11 A10 B10 C10 D10 A25 B25 C25 D25 (7A) XS12 A11 B11 C11 D11 A26 B26 C26 D26 (7B) XS13 A12 B12 C12 D12 A27 B27 C27 D27 (7C) XS14 A13 B13 C13 D13 A28 B28 C28 D28 (7D) XS15 A14 B14 C14 D14 A29 B29 C29 D29 (7E) XS16 A15 B15 C15 D15 A30 B30 C30 D30 (7F) Transmit CAS Register (16:1) The transmit CAS register access is enabled by setting bit XSP.CASEN = 1. Each register except XS1 contains the CAS bits for two time slots. With the transmit multiframe begin ISR1.XMB the contents of these registers is copied into a shadow register. The contents is sent out subsequently in the time slots 16 of the outgoing data stream. Note: If ISR1.XMB is not used and the write access to these registers is done exact in the moment when this interrupt is generated, data is lost. XS1.7 is sent out first and XS16.0 is sent last. The transmit multiframe begin interrupt (XMB) requests that these registers should be serviced. If requests for new information are ignored, current contents is repeated. XS1 has to be programmed with the multiframe pattern. This pattern should always stay low otherwise the remote end loses its synchronization. With setting the Y-bit a remote alarm is transmitted to the far end. The X bits (spare bits) should be set if they are not used. Data Sheet 263 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers If access to these registers is done without control of the interrupt ISR1.XMB the registers should be written twice to avoid an internal data transfer error. Note: A software reset (CMDR.XRES) resets these registers. Port Configuration 1 to 4 (Read/Write) Value after reset: 00H 7 0 PC1 RPC12 RPC11 RPC10 XPC13 XPC12 XPC11 XPC10 (80) PC2 RPC22 RPC21 RPC20 XPC23 XPC22 XPC21 XPC20 (81) PC3 RPC32 RPC31 RPC30 XPC33 XPC32 XPC31 XPC30 (82) PC4 RPC42 RPC41 RPC40 XPC43 XPC42 XPC41 XPC40 (83) RPC(2:0) Receive multifunction port configuration The multifunction ports RP(A to D) are bidirectional. After Reset these ports are configured as inputs. With the selection of the pin function the In/Output configuration is also achieved. The input function SYPR may only be selected once, it must not be selected twice or more. Register PC1 configures port RPA, while PC2 → port RPB, PC3 → port RPC and PC4 → port RPD. 000 = SYPR: Synchronous Pulse Receive (Input) Together with register RC(1:0) SYPR defines the frame begin on the receive system interface. Because of the offset programming the SYPR and the RFM pin function cannot be selected in parallel. 001 = RFM: Receive Frame Marker (Output) CMR2.IRSP = 0: The receive frame marker is active high for one 2.048 MHz period during any bit position of the current frame. Programming of the bit position is done by using registers RC(1:0). The internal time slot assigner is disabled. The RFM offset calculation formula has to be used. CMR2.IRSP = 1: Internally generated frame synchronization pulse sourced by the DCO-R circuitry. The pulse is active low for one 2.048 MHz period. Data Sheet 264 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 010 =RMFB: Receive Multiframe Begin (Output) Marks the beginning of every received multiframe or optionally the begin of every CAS multiframe begin (active high). 011 = RSIGM: Receive Signaling Marker (Output) Marks the time slots which are defined by register RTR(4:1) of every frame on port RDO. 100 = RSIG: Receive Signaling Data (Output) The received CAS multiframe is transmitted on this pin. Time slot on RSIG correlates directly to the time slot assignment on RDO. 101 = DLR: Data Link Bit Receive (Output) Marks the Sa-bits within the data stream on RDO. 110 = FREEZE: Freeze Signaling (Output) The freeze signaling status is active high by detecting a loss-ofsignal alarm, or a loss of CAS frame alignment or a receive slip (positive or negative). It stays high for at least one complete multiframe after the alarm disappears. Setting SIC2.FFS enforces a high on pin FREEZE. 111 = RFSP: Receive Frame Synchronous Pulse (Output) Marks the frame begin in the receivers synchronous state. This marker is active low for 488 ns with a frequency of 8 kHz. XPC(3:0) Transmit multifunction Port Configuration The multifunction ports XP(A to D) are bidirectional. After Reset these ports are configured as inputs. With the selection of the pin function the In/Output configuration is also achieved. Each of the four different input functions (SYPX, XMFS, XSIG, TCLK) may only be selected once. No input function must be selected twice or more. SYPX and XMFS should not be selected in parallel. Register PC1 configures port XPA, while PC2 → port XPB, PC3 → port XPC and PC4 → port XPD. 0000 = SYPX: Synchronous Pulse Transmit (Input) Together with register XC(1:0) SYPX defines the frame begin on the transmit system interface ports XDI and XSIG. 0001 = XMFS: Transmit Multiframe Synchronization (Input) Together with register XC(1:0) XMFS defines the frame and multiframe begin on the transmit system interface ports XDI and XSIG. Depending on PC5.CXMFS the signal on XMFS is active high or low. 0010 = XSIG: Transmit Signaling Data (Input) Input for transmit signaling data received from the signaling Data Sheet 265 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers highway. Optionally sampling of XSIG data is controlled by the active high XSIGM marker. 0011 = TCLK: Transmit Clock (Input) A 2.048/8.192 MHz clock has to be sourced by the system if the internal generated transmit clock (DCO-X) is not used. Optionally this input is used as a synchronization clock for the DCO-X circuitry with a frequency of 2.048 MHz. 0100 = XMFB: Transmit Multiframe Begin (Output) Marks the beginning of every transmit multiframe. 0101 = XSIGM: Transmit Signaling Marker (Output) Marks the time slots which are defined by register TTR(4:1) of every frame on port XDI. 0110 = DLX: Data Link Bit Transmit (Output) Marks the Sa-bits within the data stream on XDI. 0111 = XCLK: Transmit Line Clock (Output) Frequency: 2.048 MHz 1000 = XLT: Transmit Line Tristate (Input) With a high level on this port the transmit lines XL1/2 or XDOP/N are set directly into tristate. This pin function is logically ored with register XPM2.XLT. Port Configuration 5 (Read/Write) Value after reset: 00H 7 0 PC5 CCLK2 CCLK1 Data Sheet CCLK2 CCLK1 CXMFS 0 CSRP CRP (84) Configure CLK2 Port 0= CLK2 is input 1= CLK2 is output (only, if DCO-X is active) Configure CLK1 Port 0= CLK1 is input 1= CLK1 is output (only, if DCO-R is active) 266 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers CXMFS Configure XMFS Port PC5(2) 0= Port XMFS is active low. 1= Port XMFS is active high. reserved. Must be cleared CSRP Configure SCLKR Port CRP 0= SCLKR: Input 1= SCLKR: Output Configure RCLK Port 0= RCLK: Input 1= RCLK: Output Global Port Configuration 1 (Read/Write) Value after reset: 00H 7 0 GPC1 CSFP1 CSFP0 (85) CSFP(1:0) Configure SEC/FSC Port The FSC pulse is generated if the DCO-R circuitry of the selected channel is active (CMR2.IRSC = 1 or CMR1.RS(1:0) = 10 or 11). 00 = SEC: Input, active high 01 = SEC: Output, active high 10 = FSC: Output, active high 11 = FSC: Output, active low Data Sheet 267 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Port Configuration 6 (Read/Write) Value after reset: 00H 7 0 PC6 SXCL(1:0) SXCL1 SXCL0 SCL2 SCL1 SCL0 (86) Select Transmit Clock Frequency on Port CLK2 Port CLK2 is the de-jittered DCO-X clock at a frequency of 00 = 2.048 MHz 01 = 4.096 MHz 10 = 8.192 MHz 11 = 16.384 MHz Note: If DCO-X is not used, no clock is output on pin CLK2 (SIC1.XBS(1:0)=00 and CMR1.DXJA=1; buffer bypass and no jitter attenuation) SCL(2:0) Select System Clock Frequency on Port CLK1 Port CLK1 is the de-jittered DCO-R clock at a frequency of 000 = 8 kHz 001 = 2.048 MHz 010 = 4.096 MHz 011 = 8.192 MHz 100 = 16.384 MHz 101 to 111 = Not defined Note: If DCO-R is not active, no clock is output on pin CLK1 (SIC1.RBS(1:0)=11 and CMR1.RS1=0). Data Sheet 268 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Command Register 2 (Write) Value after reset: 00H CMDR2 RSUC RSUC (x87) Reset Signaling Unit Counter After setting this bit the SS7 signaling unit counter and error counter are reset.The bit is cleared automatically after execution. Note: The maximum time between writing to the CMDR2 register and the execution of the command takes 2.5 periods of the current system data rate. Therefore, if the CPU operates with a very high clock rate in comparison with the FALC56's clock, it is recommended that bit SIS.CEC should be checked before writing to the CMDR2 register to avoid any loss of commands. Command Register 3 (Write) Value after reset: 00H 7 CMDR3 RMC2 RMC2 0 XREP2 XHF2 XTF2 XME2 SRES2 (88) Receive Message Complete - HDLC Channel 2 Confirmation from CPU to FALC® that the current frame or data block has been fetched following an RPF2 or RME2 interrupt, thus the occupied space in the RFIFO2 can be released. XREP2 Transmission Repeat - HDLC Channel 2 If XREP2 is set together with XTF2 (write 24H to CMDR3), the FALC® repeatedly transmits the contents of the XFIFO2 (1 to 32 bytes) without HDLC framing fully transparently, i.e. without flag, CRC. The cyclic transmission is stopped with an SRES2 command or by resetting XREP2. XHF2 Transmit HDLC Frame - HDLC Channel 2 After having written up to 32 bytes to the XFIFO2, this command initiates the transmission of a HDLC frame. Data Sheet 269 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XTF2 Transmit Transparent Frame - HDLC Channel 2 Initiates the transmission of a transparent frame without HDLC framing. XME2 Transmit Message End - HDLC Channel 2 Indicates that the data block written last to the XFIFO2 completes the current frame. The FALC® can terminate the transmission operation properly by appending the CRC and the closing flag sequence to the data. SRES2 Signaling Transmitter Reset - HDLC Channel 2 The transmitter of the signaling controller is reset. XFIFO2 is cleared of any data and an abort sequence (seven 1s) followed by interframe time fill is transmitted. In response to SRES2 an XPR2 interrupt is generated. This command can be used by the CPU to abort a frame currently in transmission. Command Register 4 (Write) Value after reset: 00H 7 CMDR4 RMC3 RMC3 0 XREP3 XHF3 XTF3 XME3 SRES3 (89) Receive Message Complete - HDLC Channel 3 Confirmation from CPU to FALC® that the current frame or data block has been fetched following an RPF3 or RME3 interrupt, thus the occupied space in the RFIFO3 can be released. XREP3 Transmission Repeat - HDLC Channel 3 If XREP3 is set together with XTF3 (write 24H to CMDR4), the FALC® repeatedly transmits the contents of the XFIFO3 (1 to 32 bytes) without HDLC framing fully transparently, i.e. without flag, CRC. The cyclic transmission is stopped with an SRES3 command or by resetting XREP3. XHF3 Transmit HDLC Frame - HDLC Channel 3 After having written up to 32 bytes to the XFIFO3, this command initiates the transmission of a HDLC frame. Data Sheet 270 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XTF3 Transmit Transparent Frame - HDLC Channel 3 Initiates the transmission of a transparent frame without HDLC framing. XME3 Transmit Message End - HDLC Channel 3 Indicates that the data block written last to the XFIFO3 completes the current frame. The FALC® can terminate the transmission operation properly by appending the CRC and the closing flag sequence to the data. SRES3 Signaling Transmitter Reset - HDLC Channel 3 The transmitter of the signaling controller is reset. XFIFO3 is cleared of any data and an abort sequence (seven 1s) followed by interframe time fill is transmitted. In response to SRES3 an XPR3 interrupt is generated. This command can be used by the CPU to abort a frame currently in transmission. Common Configuration Register 3 (Read/Write) Value after reset: 00H 7 0 CCR3 RADD2 RCRC2 XCRC2 ITF2 XMFA2 RADD2 Receive Address Pushed to RFIFO2 RFT12 RFT02 (8B) If this bit is set, the received HDLC channel 2 address information (1 or 2 bytes, depending on the address mode selected via MODE2.MDS02) is pushed to RFIFO2. This function is applicable in non-auto mode and transparent mode 1. RCRC2 Receive CRC ON/OFF - HDLC Channel 2 Only applicable in non-auto mode. If this bit is set, the received CRC checksum is written to RFIFO2 (CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in the received frame, is followed in the RFIFO2 by the status information byte (contents of register RSIS2). The received CRC checksum will additionally be checked for correctness. If non-auto mode is selected, the limits for “Valid Frame” check are modified. Data Sheet 271 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XCRC2 Transmit CRC ON/OFF - HDLC Channel 2 If this bit is set, the CRC checksum will not be generated internally. It has to be written as the last two bytes in the transmit FIFO (XFIFO2). The transmitted frame is closed automatically with a closing flag. ITF2 Interframe Time Fill - HDLC Channel 2 Determines the idle (= no data to be sent) state of the transmit data coming from the signaling controller. XMFA2 0= Continuous logical "1" is output 1= Continuous flag sequences are output ("01111110" bit patterns) Transmit Multiframe Aligned - HDLC Channel 2 Determines the synchronization between the framer and the corresponding signaling controller. RFT12, RFT02 0= The contents of the XFIFO2 is transmitted without multiframe alignment. 1= The contents of the XFIFO2 is transmitted multiframe aligned. RFIFO2 Threshold Level - HDLC Channel 2 The size of the accessible part of RFIFO2 can be determined by programming these bits. The number of valid bytes after an RPF interrupt is given in the following table: RFT12 RFT02 Size of Accessible Part of RFIFO2 0 0 1 1 0 1 0 1 32 bytes (default value) 16 bytes 4 bytes 2 bytes The value of RFT(1:0)2 can be changed dynamically if reception is not running or after the current data block has been read, but before the command CMDR3.RMC2 is issued (interrupt controlled data transfer). Data Sheet 272 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Common Configuration Register 4 (Read/Write) Value after reset: 00H 7 0 CCR4 RADD3 RCRC3 XCRC3 ITF3 XMFA3 RADD3 Receive Address Pushed to RFIFO3 RFT13 RFT03 (8C) If this bit is set, the received HDLC channel 3 address information (1 or 2 bytes, depending on the address mode selected via MODE3.MDS03) is pushed to RFIFO3. This function is applicable in non-auto mode and transparent mode 1. RCRC3 Receive CRC ON/OFF - HDLC Channel 3 Only applicable in non-auto mode. If this bit is set, the received CRC checksum is written to RFIFO3 (CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in the received frame, is followed in the RFIFO3 by the status information byte (contents of register RSIS3). The received CRC checksum will additionally be checked for correctness. If non-auto mode is selected, the limits for “Valid Frame” check are modified. XCRC3 Transmit CRC ON/OFF - HDLC Channel 3 If this bit is set, the CRC checksum will not be generated internally. It has to be written as the last two bytes in the transmit FIFO (XFIFO3). The transmitted frame is closed automatically with a closing flag. ITF3 Interframe Time Fill - HDLC Channel 3 Determines the idle (= no data to be sent) state of the transmit data coming from the signaling controller. XMFA3 0= Continuous logical "1" is output 1= Continuous flag sequences are output ("01111110" bit patterns) Transmit Multiframe Aligned - HDLC Channel 3 Determines the synchronization between the framer and the corresponding signaling controller. Data Sheet 0= The contents of the XFIFO3 is transmitted without multiframe alignment. 1= The contents of the XFIFO3 is transmitted multiframe aligned. 273 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RFT13, RFT03 RFIFO3 Threshold Level - HDLC Channel 3 The size of the accessible part of RFIFO3 can be determined by programming these bits. The number of valid bytes after an RPF interrupt is given in the following table: RFT13 RFT03 Size of Accessible Part of RFIFO3 0 0 1 1 0 1 0 1 32 bytes (default value) 16 bytes 4 bytes 2 bytes The value of RFT13/03 can be changed dynamically if reception is not running or after the current data block has been read, but before the command CMDR4.RMC3 is issued (interrupt controlled data transfer). Common Configuration Register 5 (Read/Write) Value after reset: 00H 7 0 CCR5 SUET CSF AFX (x8D) Note: These bits are only valid, if SS7 mode of HDLC channel 1 is selected. SUET CSF AFX Data Sheet Signaling Unit Error Threshold Defines the number of signaling units received in error that will cause an error rate high indication (ISR1.SUEX). 0= Threshold 64 errored signaling units 1= Threshold 32 errored signaling units Compare Status Field If the status fields of consecutive LSSUs are equal, only the first is stored and every following is ignored. 0= Compare disabled. 1= Compare enabled. Automatic FISU Transmission After the contents of the transmit FIFO (XFIFO) has been transmitted completely, FISUs are transmitted automatically. These FISUs contain the FSN and BSO of the last transmitted signaling unit. 274 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 0= Automatic FISU transmission disabled. 1= Automatic FISU transmission enabled. Mode Register 2 (Read/Write) Value after reset: 00H 7 MODE2 MDS22 MDS2(2:0) 0 MDS21 MDS20 HRAC2 DIV2 (8E) Mode Select - HDLC Channel 2 The operating mode of the HDLC controller is selected. 000 = Reserved 001 = Reserved 010 = One-byte address comparison mode (RAL1, 2) 011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2) 100 = No address comparison 101 = One-byte address comparison mode (RAH1, 2) 110 = Reserved 111 = No HDLC framing mode 1 HRAC2 Receiver Active - HDLC Channel 2 Switches the HDLC receiver to operational or inoperational state. DIV2 0= Receiver inactive 1= Receiver active Data Inversion - HDLC Channel 2 Setting this bit will invert the internal generated HDLC data stream. Data Sheet 0= Normal operation, HDLC data stream not inverted 1= HDLC data stream inverted 275 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Mode Register 3 (Read/Write) Value after reset: 00H 7 MODE3 MDS32 MDS3(2:0) 0 MDS31 MDS30 HRAC3 DIV3 (8F) Mode Select - HDLC Channel 3 The operating mode of the HDLC controller is selected. 000 = Reserved 001 = Reserved 010 = One-byte address comparison mode (RAL1, 2) 011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2) 100 = No address comparison 101 = One-byte address comparison mode (RAH1, 2) 110 = Reserved 111 = No HDLC framing mode 1 HRAC3 Receiver Active - HDLC Channel 3 Switches the HDLC receiver to operational or inoperational state. DIV3 0= Receiver inactive 1= Receiver active Data Inversion - HDLC Channel 3 Setting this bit will invert the internal generated HDLC data stream. Data Sheet 0= Normal operation, HDLC data stream not inverted 1= HDLC data stream inverted 276 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Global Clock Mode Register 1 (Read/Write) Value after reset: 00H 7 GCM1 0 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 7 6 5 4 3 2 1 0 PHD_E1(7:0) (92) Frequency Adjust for E1 For details see calculation formulas below. Global Clock Mode Register 2 (Read/Write) Value after reset: 00H 7 GCM2 0 DVM_E1 DVM_E1 DVM_E1 VFREQ_ PHD_E1 PHD_E1 PHD_E1 PHD_E1 2 1 0 EN 11 10 9 8 PHD_E1(8:11) (93) Frequency Adjust for E1 For details see calculation formulas below. VFREQ_EN DVM_E1(0:2) Variable Frequency Enable 0= Fixed clock frequency of 2.048 (E1) or 1.544 MHz (T1/J1) 1= Variable master clock frequency Divider Mode for E1 000 = Not valid 001 = Divide by DIV_E1 = 3 010 = Divide by DIV_E1 = 4 1/6 011 = Divide by DIV_E1 = 4 100 = Divide by DIV_E1 = 5.5 101 = Divide by DIV_E1 = 5 1/3 110 = Divide by DIV_E1 = 5 2/3 111 = Not valid Data Sheet 277 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Global Clock Mode Register 3 (Read/Write) Value after reset: 00H 7 GCM3 0 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 7 6 5 4 3 2 1 0 PHD_T1(7:0) (94) Frequency Adjust for T1 For details see calculation formulas below. Global Clock Mode Register 4 (Read/Write) Value after reset: 00H 7 GCM4 0 DVM_T1 DVM_T1 DVM_T1 2 1 0 PHD_T1(8:11) 0 PHD_T1 PHD_T1 PHD_T1 PHD_T1 11 10 9 8 (95) Frequency Adjust for T1 For details see calculation formulas below. DVM_T1(0:2) Divider Mode for T1 000 = Not valid 001 = Divide by DIV_T1 = 3 010 = Divide by DIV_T1 = 4 1/6 011 = Divide by DIV_T1 = 4 100 = Divide by DIV_T1 = 5.5 101 = Divide by DIV_T1 = 5 1/3 110 = Divide by DIV_T1 = 5 2/3 111 = Not valid GCM4.4 Reserved Must be cleared. Data Sheet 278 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Global Clock Mode Register 5 (Read/Write) Value after reset: 00H 7 GCM5 0 MCLK_ LOW MCLK_LOW PLL_M(4:0) PLL_M 4 PLL_M 3 PLL_M 2 PLL_M 1 PLL_M 0 (96) Master Clock Range Low 0= Master clock frequency divided by (PLL_M+1) is greater than or equal 1.5 MHz 1= Master clock frequency divided by (PLL_M+1) is less than 1.5 MHz PLL Dividing Factor M For details see calculation formulas below. Note: Write operations to GCM5 initiate a PLL reset (see below). Global Clock Mode Register 6 (Read/Write) Value after reset: 00H 7 GCM6 PLL_N(4:0) 0 PLL_N 4 PLL_N 3 PLL_N 2 PLL_N 1 PLL_N 0 (97) PLL Dividing Factor N For details see calculation formulas below. Note: Write operations to GCM6 initiate a PLL reset (see below). Data Sheet 279 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Flexible Clock Mode Settings If flexible master clock mode is used (VFREQ_EN = 1), the according register settings can be calculated as follows (a windows-based program for automatic calculation is available, see Chapter 13.3 on page 481). For some of the standard frequencies see the table below. 1. PLL_M and PLL_N must fulfill the equations: a. 1.5 MHz ≤ fMCLK / (PLL_M+1) ≤ 2.048 MHz b. If (a.) is not possible, set MCLK_LOW and fulfill 1.02 MHz ≤ fMCLK / (PLL_M+1) ≤ 1.5 MHz c. 65 MHz ≤ fMCLK × (2×PLL_N+2) / (PLL_M+1) ≤ 69.7 MHz (as high as possible within this range) 2. Selection of dividing mode to best fulfill: foutE1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_E1 (target E1: 16.384 MHz) foutT1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_T1 (target T1: 12.352 MHz) Though the target frequency might not be met directly, the dividing mode has to be selected to reach a frequency, which is as near as possible to the target frequency. 3. Calculation of correction value (frequency mismatch correction) PHD_E1 = 6 × 4096 × [DIV_E1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/16.384 MHz)] PHD_T1 = 6 × 4096 × [DIV_T1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/12.352 MHz)] The result of these equations will be in the range of -2048 to +2047. Negative values are represented in 2s-complement format (e.g. -2000D = 830H; +2000D = 7D0H). Table 60 Clock Mode Register Settings for E1 or T1/J1 fMCLK [MHz] GCM1 GCM2 GCM3 GCM4 GCM5 GCM6 1.544 F0H 51H 00H 80H 00H 15H 2.048 00H 58H D2H C2H 00H 10H 8.192 00H 58H D2H C2H 03H 10H 10.000 90H 51H 81H 8FH 04H 10H 12.352 F0H 51H 00H 80H 07H 15H Data Sheet 280 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Transmit FIFO 2 (Write) Value after reset: 00H 7 0 XFIFO2 XF7 XF0 (x9C) XFIFO2 XF15 XF8 (x9D) XF(15:0) Transmit FIFO for HDLC Channel 2 The function is equivalent to XFIFO. Transmit FIFO 3 (Write) Value after reset: 00H 7 0 XFIFO3 XF7 XF0 (x9E) XFIFO3 XF15 XF8 (x9F) XF(15:0) Transmit FIFO for HDLC Channel 3 The function is equivalent to XFIFO. Time Slot Even/Odd Select (Read/Write) Value after reset: 00H 7 TSEO 0 EO31 EO30 EO21 EO20 EO11 EO10 (A0) HDLC protocol data can be sent in even, odd or both frames of a multiframe. Even frames are frame number 2, 4,and so on, odd frames are frame number 1, 3, and so on. The selection refers to receive and transmit direction as well. Each multiframe starts with an odd frame and ends with an even frame. By default all frames are used for HDLC reception and transmission. Note: The different HDLC channels have to be configured to use different time slots, bit positions or frames. Data Sheet 281 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers EO1(1:0) Even/Odd frame selection HDLC Channel 1 Channel 1 HDLC protocol data can be sent in even, odd or both frames of a multiframe. 00 = Even and odd frames 01 = Odd frames only 10 = Even frames only 11 = Undefined EO2(1:0) Even/Odd frame selection HDLC Channel 2 Channel 2 HDLC protocol data can be sent in even, odd or both frames of a multiframe. 00 = Even and odd frames 01 = Odd frames only 10 = Even frames only 11 = Undefined EO3(1:0) Even/Odd frame selection HDLC Channel 3 Channel 3 HDLC protocol data can be sent in even, odd or both frames of a multiframe. 00 = Even and odd frames 01 = Odd frames only 10 = Even frames only 11 = Undefined Time Slot Bit Select 1 (Read/Write) Value after reset: FFH 7 TSBS1 TSB17 TSB1(7:0) 0 TSB16 TSB15 TSB14 TSB13 TSB12 TSB11 TSB10 (A1) Time Slot Bit Selection - HDLC Channel 1 Only bits selected by this register are used for HDLC channel 1 in selected time slots. Time slot selection is done by setting the appropriate bits in registers TTR(4:1) and RTR(4:1) independently for receive and transmit direction. Bit selection is common to receive and transmit direction. By default all bit positions within the selected time slot(s) are enabled. 0 = Bit position x in selected time slot(s) is not used for HDLC channel 1 reception and transmission. Data Sheet 282 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 1 = Bit position x in selected time slot(s) is used for HDLC channel 1 reception and transmission. Time Slot Bit Select 2 (Read/Write) Value after reset: FFH 7 TSBS2 TSB27 TSB2(7:0) 0 TSB26 TSB25 TSB24 TSB23 TSB22 TSB21 TSB20 (A2) Time Slot Bit Selection - HDLC Channel 2 Only bits selected by this register are used for HDLC channel 2 in selected time slots. Time slot selection is done by setting the appropriate bits in register TSS2. Bit selection is common to receive and transmit direction. By default all bit positions within the selected time slot are enabled. 0 = Bit position x in selected time slot(s) is not used for HDLC channel 2 reception and transmission. 1 = Bit position x in selected time slot(s) is used for HDLC channel 2 reception and transmission. Time Slot Bit Select 3 (Read/Write) Value after reset: FFH 7 TSBS3 TSB37 TSB3(7:0) 0 TSB36 TSB35 TSB34 TSB33 TSB32 TSB31 TSB30 A3) Time Slot Bit Selection - HDLC Channel 3 Only bits selected by this register are used for HDLC channel 3 in selected time slots. Time slot selection is done by setting the appropriate bits in register TSS3. Bit selection is common to receive and transmit direction. By default all bit positions within the selected time slot are enabled. 0 = Bit position x in selected time slot(s) is not used for HDLC channel 3 reception and transmission. 1 = Bit position x in selected time slot(s) is used for HDLC channel 3 reception and transmission. Data Sheet 283 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Time Slot Select 2 (Read/Write) Value after reset: 00H 7 0 TSS2 TSS24 TSS2(4:0) TSS23 TSS22 TSS21 TSS20 (A4) Time Slot Selection Code - HDLC Channel 2 Defines the time slot used by HDLC channel 2. 00000 =No time slot selected 00001 =Time slot 1 ... 11111 =Time slot 31 Note:Different HDLC channels must use different time slots. Time Slot Select 3 (Read/Write) Value after reset: 00H 7 0 TSS3 TSB3(4:0) TSS34 TSS33 TSS32 TSS31 TSS30 (A5) Time Slot Selection Code - HDLC Channel 3 Defines the time slot used by HDLC channel 3. 00000 =No time slot selected 00001 =Time slot 1 ... 11111 =Time slot 31 Note:Different HDLC channels must use different time slots. Data Sheet 284 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Test Pattern Control Register 0 (Read/Write) Value after reset: 00H 7 0 TPC0 FRA (A8) FRA Framed/Unframed Selection 0 = PRBS is generated/monitored unframed. Framing information is overwritten by the generator. 1= Data Sheet PRBS is generated/monitored framed. Time slot 0 is not overwritten by the generator and not observed by the monitor. 285 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 9.3 E1 Status Register Addresses Table 61 E1 Status Register Address Arrangement Address Register Type Comment Page 00 RFIFO R Receive FIFO 289 01 RFIFO R Receive FIFO 289 49 RBD R Receive Buffer Delay 289 4A VSTR R Version Status Register 290 4B RES R Receive Equalizer Status 290 4C FRS0 R Framer Receive Status 0 291 4D FRS1 R Framer Receive Status 1 294 4E RSW R Receive Service Word 295 4F RSP R Receive Spare Bits 296 50 FECL R Framing Error Counter Low 298 51 FECH R Framing Error Counter High 298 52 CVCL R Code Violation Counter Low 299 53 CVCH R Code Violation Counter High 299 54 CEC1L R CRC Error Counter 1 Low 300 55 CEC1H R CRC Error Counter 1 High 300 56 EBCL R E-Bit Error Counter Low 301 57 EBCH R E-Bit Error Counter High 301 58 CEC2L R CRC Error Counter 2 Low 302 59 CEC2H R CRC Error Counter 2 High 302 5A CEC3L R CRC Error Counter 3 Low 303 5B CEC3H R CRC Error Counter 3 High 303 5C RSA4 R Receive Sa4-Bit Register 304 5D RSA5 R Receive Sa5-Bit Register 304 5E RSA6 R Receive Sa6-Bit Register 304 5F RSA7 R Receive Sa7-Bit Register 304 60 RSA8 R Receive Sa8-Bit Register 304 61 RSA6S R Receive Sa6-Bit Status Register 305 62 RSP1 R Receive Signaling Pointer 1 306 63 RSP2 R Receive Signaling Pointer 2 306 Data Sheet 286 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Table 61 E1 Status Register Address Arrangement (cont’d) Address Register Type Comment Page 64 SIS R Signaling Status Register 307 65 RSIS R Receive Signaling Status Register 308 66 RBCL R Receive Byte Control Low 310 67 RBCH R Receive Byte Control High 310 68 ISR0 R Interrupt Status Register 0 310 69 ISR1 R Interrupt Status Register 1 312 6A ISR2 R Interrupt Status Register 2 314 6B ISR3 R Interrupt Status Register 3 316 6C ISR4 R Interrupt Status Register 4 317 6D ISR5 R Interrupt Status Register 5 319 6E GIS R Global Interrupt Status 321 70 RS1 R Receive CAS Register 1 322 71 RS2 R Receive CAS Register 2 322 72 RS3 R Receive CAS Register 3 322 73 RS4 R Receive CAS Register 4 322 74 RS5 R Receive CAS Register 5 322 75 RS6 R Receive CAS Register 6 322 76 RS7 R Receive CAS Register 7 322 77 RS8 R Receive CAS Register 8 322 78 RS9 R Receive CAS Register 9 322 79 RS10 R Receive CAS Register 10 322 7A RS11 R Receive CAS Register 11 322 7B RS12 R Receive CAS Register 12 322 7C RS13 R Receive CAS Register 13 322 7D RS14 R Receive CAS Register 14 322 7E RS15 R Receive CAS Register 15 322 7F RS16 R Receive CAS Register 16 322 90 RBC2 R Receive Byte Count Register 2 323 91 RBC3 R Receive Byte Count Register 3 323 98 SIS2 R Signaling Status Register 2 323 Data Sheet 287 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Table 61 E1 Status Register Address Arrangement (cont’d) Address Register Type Comment 99 RSIS2 R Receive Signaling Status Register 2 325 9A SIS3 R Signaling Status Register 3 9B RSIS3 R Receive Signaling Status Register 3 327 9C RFIFO2 R Receive FIFO 2 329 9D RFIFO2 R Receive FIFO 2 329 9E RFIFO3 R Receive FIFO 3 329 9F RFIFO3 R Receive FIFO 3 329 EC WID R Identification Register 329 Data Sheet 288 Page 326 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers 9.4 Detailed Description of E1 Status Registers Receive FIFO - HDLC Channel 1 (Read) 7 0 RFIFO RF7 RF0 (00) RFIFO RF15 RF8 (01) Reading data from RFIFO of HDLC channel 1 can be done in an 8-bit (byte) or 16-bit (word) access depending on the selected bus interface mode. The LSB is received first from the serial interface. The size of the accessible part of RFIFO is determined by programming the bits CCR1.RFT(1:0) (RFIFO threshold level). It can be reduced from 32 bytes (reset value) down to 2 bytes (four values: 32, 16, 4, 2 bytes). Data Transfer Up to 32 bytes/16 words of received data can be read from the RFIFO following an RPF or an RME interrupt. RPF Interrupt: A fixed number of bytes/words to be read (32, 16, 4, 2 bytes). The message is not yet complete. RME Interrupt: The message is completely received. The number of valid bytes is determined by reading the RBCL, RBCH registers. RFIFO is released by issuing the RMC (Receive Message Complete) command. Receive Buffer Delay (Read) 7 RBD RBD(5:0) 0 RBD5 RBD4 RBD3 RBD2 RBD1 RBD0 (49) Receive Elastic Buffer Delay These bits informs the user about the current delay (in time slots) through the receive elastic buffer. The delay is updated every 512 or 256 bits (SIC1.RBS(1:0)). Before reading this register the user has to set bit DEC.DRBD in order to halt the current value of this register. After reading RBD updating of this register is enabled. Not valid if the receive buffer is bypassed. 000000 = Delay < 1 time slot ... 111111 = Delay > 63 time slots Data Sheet 289 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Version Status Register (Read) VSTR 7 0 VN7 VN0 VN(7:0) (4A) Version Number of Chip 00H =Version 1.2 Receive Equalizer Status (Read) 7 RES EV(1:0) EV1 0 EV0 RES4 RES3 RES2 RES1 RES0 (4B) Equalizer Status Valid These bits informs the user about the current state of the receive equalization network. Only valid if LIM1.EQON is set. 00 = Equalizer status not valid, still adapting 01 = Equalizer status valid 10 = Equalizer status not valid 11 = Equalizer status valid but high noise floor RES(4:0) Receive Equalizer Status The current line attenuation status in steps of about 1.7 dB are displayed in these bits. Only valid if bits EV(1:0) = 01 and LIM1.EQON = 1. Accuracy: ± 2 digits, based on temperature influence and noise amplitude variations. 00000 = Minimum attenuation: 0 dB ... 11001 = Maximum attenuation: -43 dB Data Sheet 290 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Framer Receive Status Register 0 (Read) 7 FRS0 LOS LOS 0 AIS LFA RRA NMF LMFA (4C) Loss-of-Signal Detection: This bit is set when the incoming signal has “no transitions” (analog interface) or logical zeros (digital interface) in a time interval of T consecutive pulses, where T is programmable by register PCD. Total account of consecutive pulses: 16 < T < 4096. Analog interface: The receive signal level where “no transition” is declared is defined by the programmed value of LIM1.RIL(2:0). Recovery: Analog interface: The bit is reset in short-haul mode when the incoming signal has transitions with signal levels greater than the programmed receive input level (LIM1.RIL(2:0)) for at least M pulse periods defined by register PCR in the PCD time interval. In long-haul mode additionally bit RES.6 must be set for at least 250µsec. Digital interface: The bit is reset when the incoming data stream contains at least M ones defined by register PCR in the PCD time interval. With the rising edge of this bit an interrupt status bit (ISR2.LOS) is set. The bit is also set during alarm simulation and reset, if FMR0.SIM is cleared and no alarm condition exists. AIS Alarm Indication Signal The function of this bit is determined by FMR0.ALM. FMR0.ALM = 0: This bit is set when two or less zeros in the received bit stream are detected in a time interval of 250 µs and the FALC56 is in asynchronous state (FRS0.LFA = 1). The bit is reset when no alarm condition is detected (according to ETSI standard). FMR0.ALM = 1: This bit is set when the incoming signal has two or less Zeros in each of two consecutive double frame period (512 bits). This bit is cleared when each of two consecutive doubleframe periods contain three or more zeros or when the frame alignment signal FAS has been found. (ITU-T G.775) The bit is also set during alarm simulation and reset if FMR0.SIM is cleared and no alarm condition exists. With the rising edge of this bit an interrupt status bit (ISR2.AIS) is set. Data Sheet 291 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers LFA Loss of Frame Alignment This bit is set after detecting 3 or 4 consecutive incorrect FAS words or 3 or 4 consecutive incorrect service words (can be disabled). With the rising edge of this bit an interrupt status bit (ISR2.LFA) is set. The specification of the loss of synchronization conditions is done by bits RC0.SWD and RC0.ASY4. After loss of synchronization, the frame aligner resynchronizes automatically. The following conditions have to be detected to regain synchronous state: – The presence of the correct FAS word in frame n. – The presence of the correct service word (bit 2 = 1) in frame n+1. – For a second time the presence of a correct FAS word in frame n+2. The bit is cleared when synchronization has been regained (directly after the second correct FAS word of the procedure described above has been received). If the CRC-multiframe structure is enabled by setting bit FMR2.RFS1, multiframe alignment is assumed to be lost if pulseframe synchronization has been lost. The resynchronization procedure for multiframe alignment starts after the bit FRS0.LFA has been cleared. Multiframe alignment has been regained if two consecutive CRCmultiframes have been received without a framing error (refer to FRS0.LMFA). The bit is set during alarm simulation and reset if FMR0.SIM is cleared and no alarm condition exists. If bit FRS0.LFA is cleared a loss of frame alignment recovery interrupt status ISR2.FAR is generated. RRA Receive Remote Alarm Set if bit 3 of the received service word is set. An alarm interrupt status ISR2.RA can be generated if the alarm condition is detected. FRS0.RRA is cleared if no alarm is detected. At the same time a remote alarm recovery interrupt status ISR2.RAR is generated. The bit RSW.RRA has the same function. Both status and interrupt status bits are set during alarm simulation. Data Sheet 292 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers NMF No Multiframe Alignment Found This bit is only valid if the CRC4 interworking is selected (FMR2.RFS(1:0) = 11). Set if the multiframe pattern is not detected in a time interval of 400 ms after the framer has reached the doubleframe synchronous state. The receiver is then automatically switched to doubleframe format. This bit is reset if the basic framing has been lost. LMFA Loss of Multiframe Alignment Not used in doubleframe format (FMR2.RFS1 = 0). In this case LMFA is set. In CRC-multiframe mode (FMR2.RFS1 = 1), this bit is set – if force resynchronization is initiated by setting bit FMR0.FRS, or – if multiframe force resynchronization is initiated by setting bit FMR1.MFCS, or – if pulseframe alignment has been lost (FRS0.LFA). It is reset if two CRC-multiframes have been received at an interval of n × 2 ms (n = 1, 2, 3 and so forth) without a framing error. If bit FRS0.LMFA is cleared a loss of multiframe alignment recovery interrupt status ISR2.MFAR is generated. Data Sheet 293 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Framer Receive Status Register 1 (Read) 7 FRS1 EXZD EXZD 0 TS16RA TS16LOS TS16AIS TS16LFA XLS XLO (4D) Excessive Zeros Detected Significant only, if excessive zero detection has been enabled (FMR0.EXZE = 1). Set after detection of more than 3 (HDB3 code) or 15 (AMI code) contiguous zeros in the received data stream. This bit is cleared on read. TS16RA Receive Time Slot 16 Remote Alarm This bit contains the actual information of the received remote alarm bit RS1.2 in time slot 16. Setting and resetting of this bit causes an interrupt status change ISR3.RA16. TS16LOS Receive Time Slot 16 Loss-of-Signal This bit is set if the incoming TS16 data stream contains always zeros for at least 16 contiguously received time slots. A one in a time slot 16 resets this bit. TS16AIS Receive Time Slot 16 Alarm Indication Signal The detection of the alarm indication signal in time slot 16 is according to ITU-T G.775. This bit is set if the incoming TS16 contains less than 4 zeros in each of two consecutive TS16 multiframe periods. This bit is cleared if two consecutive received CAS multiframe periods contains more than 3 zeros or the multiframe pattern was found in each of them. This bit is cleared if TS0 synchronization is lost. TS16LFA Data Sheet Receive Time Slot 16 Loss of Multiframe Alignment 0= The CAS controller is in synchronous state after frame alignment is accomplished. 1= This bit is set if the framing pattern "0000" in 2 consecutive CAS multiframes were not found or in all TS16 of the preceding multiframe all bits were reset. An interrupt ISR3.LMFA16 is generated. 294 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XLS Transmit Line Short Significant only if the ternary line interface is selected by LIM1.DRS = 0. XLO 0= Normal operation. No short is detected. 1= The XL1 and XL2 are shortened for at least 3 pulses. As a reaction of the short the pins XL1 and XL2 are automatically forced into a high-impedance state if bit XPM2.DAXLT is reset. After 128 consecutive pulse periods the outputs XL1/2 are activated again and the internal transmit current limiter is checked. If a short between XL1/2 is still further active the outputs XL1/2 are in high-impedance state again. When the short disappears pins XL1/2 are activated automatically and this bit is reset. With any change of this bit an interrupt ISR1.XLSC is generated. In case of XPM2.XLT is set this bit is frozen. Transmit Line Open 0= Normal operation 1= This bit is set if at least 32 consecutive zeros were sent on pins XL1/XL2 or XDOP/XDON. This bit is reset with the first transmitted pulse. With the rising edge of this bit an interrupt ISR1.XLSC is set. In case of XPM2.XLT is set this bit is frozen. Receive Service Word Pulseframe (Read) 7 RSW RSI RSI 0 RRA RY0 RY1 RY2 RY3 RY4 (4E) Receive Spare Bit for International Use First bit of the received service word. It is fixed to one if CRCmultiframe mode is enabled. RRA Receive Remote Alarm Equivalent to bit FRS0.RRA. RY(4:0) Data Sheet Receive Spare Bits for National Use (Y-Bits, Sn-Bits, Sa-Bits) 295 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Spare Bits/Additional Status (Read) 7 RSP SI(2:1) SI1 0 SI2 LLBDD LLBAD RSIF RS13 RS15 (4F) Submultiframe Error Indication 1, 2 Not valid if doubleframe format is enabled. In this case, both bits are set. When using CRC-multiframe format these bits are set to 0= If multiframe alignment has been lost, or if the last multiframe has been received with CRC error(s). SI1 flags a CRC error in last submultiframe 1, SI2 flags a CRC error in last submultiframe 2. 1= If at multiframe synchronous state last assigned submultiframe has been received without a CRC error. Both flags are updated with the beginning of every received CRC multiframe. If automatic transmission of submultiframe status is enabled by setting bit XSP.AXS, above status information is inserted automatically in Si-bit position of every outgoing CRC multiframe (under the condition that time slot 0 transparent modes are both disabled): SI1 → Si -bit of frame 13, SI2 → Si -bit of frame 15. LLBDD Line Loop-Back Deactivation Signal Detected This bit is set in case of the LLB deactivate signal is detected and then received over a period of more than 25 ms with a bit error rate less than 10-2. The bit remains set as long as the bit error rate does not exceed 10-2. If framing is aligned, the time slot 0 is not taken into account for the error rate calculation. Any change of this bit causes an LLBSC interrupt. LLBAD Line Loop-Back Activation Signal Detected Depending on bit LCR1.EPRM the source of this status bit changed. LCR1.EPRM = 0: This bit is set in case of the LLB activate signal is detected and then received over a period of more than 25 ms with a bit error rate less than 10-2. The bit remains set as long as the bit error rate does not exceed 10-2. Data Sheet 296 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers If framing is aligned, the time slot 0 is not taken into account for the error rate calculation. Any change of this bit causes an LLBSC interrupt. PRBS Status LCR1.EPRM = 1: The current status of the PRBS synchronizer is indicated in this bit. It is set high if the synchronous state is reached even in the presence of a bit error rate of 10-1. A data stream containing all zeros or all ones with/without framing bits is also a valid pseudo-random binary sequence. RSIF Receive Spare Bit for International Use (FAS Word) First bit in FAS-word. Used only in doubleframe format, otherwise fixed to "1". RS13 Receive Spare Bit (Frame 13, CRC Multiframe) First bit in service word of frame 13. Significant only in CRCmultiframe format, otherwise fixed to "0". This bit is updated with beginning of every received CRC multiframe. RS15 Receive Spare Bit (Frame 15, CRC Multiframe) First bit in service word of frame 15. Significant only in CRCmultiframe format, otherwise fixed to "0". This bit is updated with beginning of every received CRC multiframe. Data Sheet 297 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Framing Error Counter (Read) FECL FECH FE(15:0) 7 0 FE7 FE0 7 0 FE15 FE8 (50) (51) Framing Errors This 16-bit counter is incremented when a FAS word has been received with an error. Framing errors are counted during basic frame synchronous state only (but even if multiframe synchronous state is not reached yet). During alarm simulation, the counter is incremented every 250 µs up to its saturation. The error counter does not roll over. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DFEC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DFEC is reset automatically with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 298 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Code Violation Counter (Read) CVCL CVCH CV(15:0) 7 0 CV7 CV0 7 0 CV15 CV8 (52) (53) Code Violations No function if NRZ code has been enabled. If the HDB3 or the CMI code with HDB3-precoding is selected, the 16bit counter is incremented when violations of the HDB3 code are detected. The error detection mode is determined by programming the bit FMR0.EXTD. If simple AMI coding is enabled (FMR0.RC0/1 = 10) all bipolar violations are counted. The error counter does not roll over. During alarm simulation, the counter is incremented every four bits received up to its saturation. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DCVC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DCVC is reset automatically with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 299 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers CRC Error Counter 1 (Read) CEC1L CEC1H CR(15:0) 7 0 CR7 CR0 7 0 CR15 CR8 (54) (55) CRC Errors No function if doubleframe format is selected. In CRC-multiframe mode, the 16-bit counter is incremented when a CRC-submultiframe has been received with a CRC error. CRC errors are not counted during asynchronous state. The error counter does not roll over. During alarm simulation, the counter is incremented once per submultiframe up to its saturation. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DCEC1 has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DCEC1 is reset automatically with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 300 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers E-Bit Error Counter (Read) EBCL EBCH EB(15:0) 7 0 EB7 EB0 7 0 EB15 EB8 (56) (57) E-Bit Errors If doubleframe format is selected, FEBEH/L has no function. If CRCmultiframe mode is enabled, FEBEH/L works as submultiframe error indication counter (16 bits) which counts zeros in Si-bit position of frame 13 and 15 of every received CRC multiframe. The error counter does not roll over. During alarm simulation, the counter is incremented once per submultiframe up to its saturation. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DEBC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DEBC is reset automatically with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 301 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers CRC Error Counter 2 (Read) CEC2L CEC2H CC(15:0) 7 0 CC7 CC0 7 0 CC15 CC8 (58) (59) CRC Error Counter (reported from TE through Sa6 -Bit) Depending on bit LCR1.EPRM the error counter increment is selected: LCR1.EPRM = 0: If doubleframe format is selected, CEC2H/L has no function. If CRCmultiframe mode is enabled, CEC2H/L works as Sa6-bit error indication counter (16 bits) which counts the Sa6-bit sequence 0001 and 0011in every received CRC submultiframe. Incrementing the counter is only possible in the multiframe synchronous state FRS0.LMFA = 0. Sa6-bit sequence: SA61, SA62, SA63, SA64 = 0001 or 0011 where SA61 is received in frame 1 or 9 in every multiframe. During alarm simulation, the counter is incremented once per submultiframe up to its saturation. Pseudo-Random Binary Sequence Error Counter LCR1.EPRM = 1: This 16-bit counter is incremented with every received PRBS bit error in the PRBS synchronous state RSP.LLBAD = 1. The error counter does not roll over. During alarm simulation, the counter is incremented continuously with every second received bit. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DCEC2 has to be set. With the rising edge of this bit updating of the buffer is stopped and the error counter is reset. Bit DEC.DCEC2 is reset automatically with reading the error counter high byte. Data Sheet 302 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then reset automatically. The latched error counter state should be read within the next second. CRC Error Counter 3 (Read) CEC3L CEC3H CE(15:0) 7 0 CE7 CE0 7 0 CE15 CE8 (5A) (5B) CRC Error Counter (detected at T Reference Point in Sa6 -Bit) GCR.ECMC = 0: If doubleframe format is selected, CEC3H/L has no function. If CRC-multiframe mode is enabled, CEC3H/L works as Sa6bit error indication counter (16 bits) which counts the Sa6-bit sequence 0010 and 0011in every received CRC submultiframe. Incrementing the counter is only possible in the multiframe synchronous state FRS0.LMFA = 0. Sa6-bit sequence: SA61, SA62, SA63, SA64 = 0010 or 0011 where SA61 is received in frame 1 or 9 in every multiframe. The error counter does not roll over. During alarm simulation, the counter is incremented once per submultiframe up to its saturation. CE(7:2) Multiframe Counter GCR.ECMC = 1: This 6 bit counter increments with each multiframe period in the asynchronous state FRS0.LFA/LMFA = 1. During alarm simulation, the counter is incremented once per multiframe up to its saturation. CE(1:0) Change of Frame Alignment Counter GCR.ECMC = 1: This 2 bit counter increments with each detected change of frame/multiframe alignment. The error counter does not roll over. During alarm simulation, the counter is incremented once per multiframe up to its saturation. Clearing and updating the counter is done according to bit FMR1.ECM. Data Sheet 303 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DCEC3 has to be set. With the rising edge of this bit updating of the buffer is stopped and the error counter is reset. Bit DEC.DCEC3 is reset automatically with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Receive Sa4-Bit Register (Read) 7 0 RSA4 RS47 RS40 (5C) RSA5 RS57 RS50 (5D) RSA6 RS67 RS60 (5E) RSA7 RS77 RS70 (5F) RSA8 RS87 RS80 (60) RS4(7:0) Receive Sa4-Bit Data (Y-Bits) RS5(7:0) Receive Sa5-Bit Data RS6(7:0) Receive Sa6-Bit Data RS7(7:0) Receive Sa7-Bit Data RS8(7:0) Receive Sa8-Bit Data This register contains the information of the eight Sax bits (x = 4 to 8) of the previously received CRC multiframe. These registers are updated with every multiframe begin interrupt ISR0.RMB. RS40 is received in bit-slot 4 of every service word in frame 1, RS47 in frame 15 RS50 is received in bit-slot 5, time slot 0, frame 1, RS57 in frame 15 RS60 is received in bit-slot 6, time slot 0, frame 1, RS67 in frame 15 RS70 is received in bit-slot 7, time slot 0, frame 1, RS77 in frame 15 RS80 is received in bit-slot 8, time slot 0, frame 1, RS87 in frame 15 Valid if CRC multiframe format is enabled by setting bits FMR2.RFS1 = 1 or FMR2.RFS(1:0) = 01 (doubleframe format). Data Sheet 304 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Sa6-Bit Status (Read) 7 RSA6S 0 S_X S_F S_E S_C S_A S_8 (61) Four consecutive received Sa6-bits are checked on the by ETS300233 defined Sa6-bit combinations. The FALC56 detects the following “fixed” Sa6-bit combinations: SA61, SA62, SA63, SA64 = 1000, 1010, 1100, 1110, 1111. All other possible 4 bit combinations are grouped to status “X”. A valid Sa6-bit combination must occur three times in a row. The corresponding status bit in this register is set. Even if the detected status is active for a short time the status bit remains active until this register is read. Reading the register resets all pending status information. With any change of state of the Sa6-bit combinations an interrupt status ISR0.SA6SC is generated. During the basic frame asynchronous state updating of this register and interrupt status ISR0.SA6SC is disabled. In multiframe format the detection of the Sa6-bit combinations can be done either synchronous or asynchronous to the submultiframe (FMR3.SA6SY). In synchronous detection mode updating of register RSA6S is done in the multiframe synchronous state (FRS0.LMFA = 0). In asynchronous detection mode updating is independent to the multiframe synchronous state. S_X Receive Sa6-Bit Status_X If none of the fixed Sa6-bit combinations are detected this bit is set. S_F Receive Sa6-Bit Status: "1111" Receive Sa6-bit status “1111” is detected for three times in a row in the Sa6-bit positions. S_E Receive Sa6-Bit Status: "1110" Receive Sa6-bit status “1110” is detected for three times in a row in the Sa6-bit positions. S_C Receive Sa6-Bit Status: "1100" Receive Sa6-bit status “1100” is detected for three times in a row in the Sa6bit positions. Data Sheet 305 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers S_A Receive Sa6-Bit Status: "1010" Receive Sa6-bit status “1010” is detected for three times in a row in the Sa6-bit positions. Receive Sa6-Bit Status: "1000" S_8 Receive Sa6-bit status “1000” is detected for three times in a row in the Sa6-bit positions. Receive Signaling Pointer 1 (Read) Value after reset: 00H 7 RSP1 RS8C RS(8:1)C 0 RS7C RS6C RS5C RS4C RS3C RS2C RS1C (62) Receive Signaling Register RS(8:1) Changed A one in each bit position indicates that the received signaling data in the corresponding RS(8:1) registers are updated. Bit RS1C is the pointer for register RS1, while RS8C points to RS8. Receive Signaling Pointer 2 (Read) Value after reset: 00H 7 RSP2 RS16C RS(16:9)C 0 RS15C RS14C RS13C RS12C RS11C RS10C RS9C (63) Receive Signaling Register RS9-16 Changed A one in each bit position indicates that the received signaling data in the corresponding RS9-16 registers are updated. Bit RS9C is the pointer for register RS9, while RS16C points to RS16. Data Sheet 306 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Signaling Status Register (Read) 7 SIS XDOV XDOV 0 XFW XREP RLI CEC SFS (64) Transmit Data Overflow - HDLC Channel 1 More than 32 bytes have been written to the XFIFO. This bit is reset – by a transmitter reset command XRES – when all bytes in the accessible half of the XFIFO have been moved in the inaccessible half. XFW Transmit FIFO Write Enable - HDLC Channel 1 Data can be written to the XFIFO. XREP Transmission Repeat - HDLC Channel 1 Status indication of CMDR.XREP. RLI Receive Line Inactive - HDLC Channel 1 Neither flags as interframe time fill nor frames are received through the signaling time slot. CEC Command Executing - HDLC Channel 1 0= No command is currently executed, the CMDR register can be written to. 1= A command (written previously to CMDR) is currently executed, no further command can be temporarily written in CMDR register. Note: CEC is active for about 2.5 periods of the current system data rate. SFS Data Sheet Status Freeze Signaling 0= Freeze signaling status inactive. 1= Freeze signaling status active 307 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Signaling Status Register (Read) 7 RSIS VFR 0 RDO CRC16 RAB HA1 HA0 LA (65) RSIS relates to the last received HDLC frame; it is copied into RFIFO when end-of-frame is recognized (last byte of each stored frame). VFR Valid Frame - HDLC Channel 1 Determines whether a valid frame has been received. 1= Valid 0= Invalid An invalid frame is either – a frame which is not an integer number of 8 bits (n×8 bits) in length (e.g. 25 bits), or – a frame which is too short taking into account the operation mode selected by MODE (MDS(2:0)) and the selection of receive CRC on/off (CCR2.RCRC) as follows: • MDS(2:0) = 011 (16 bit Address), RCRC = 0: 4 bytes; RCRC = 1: 3 or 4 bytes • MDS(2:0) = 010 (8 bit Address), RCRC = 0: 3 bytes; RCRC = 1: 2 or 3 bytes Note:Shorter frames are not reported. RDO Receive Data Overflow - HDLC Channel 1 A RFIFO data overflow has occurred during reception of the frame. Additionally, an interrupt can be generated (refer to ISR1.RDO/ IMR1.RDO). CRC16 RAB CRC16 Compare/Check - HDLC Channel 1 0= CRC check failed; received frame contains errors. 1= CRC check o.k.; received frame is error-free. Receive Message Aborted - HDLC Channel 1 This bit is set in SS7 mode, if the maximum number of octets (272+7) is exceeded. The received frame was aborted from the transmitting station. According to the HDLC protocol, this frame must be discarded by the receiver station. Data Sheet 308 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers HA1, HA0 High Byte Address Compare - HDLC Channel 1 Significant only if 2-byte address mode or SS7 mode has been selected. In operating modes which provide high byte address recognition, the FALC56 compares the high byte of a 2-byte address with the contents of two individually programmable registers (RAH1, RAH2) and the fixed values FEH and FCH (broadcast address). Depending on the result of this comparison, the following bit combinations are possible (SS7 support not active): 00 = RAH2 has been recognized 01 = Broadcast address has been recognized 10 = RAH1 has been recognized C/R = 0 (bit 1) 11 = RAH1 has been recognized C/R = 1 (bit 1) Note: If RAH1, RAH2 contain identical values, a match is indicated by "10" or "11". If Signaling System 7 support is activated (see MODE register), the bit functions are defined as follows: 00 = Not valid 01 = Fill in signaling unit (FISU) detected 10 = Link status signaling unit (LSSU) detected 11 = Message signaling unit (MSU) detected LA Low Byte Address Compare - HDLC Channel 1 Significant in HDLC modes only. The low byte address of a 2-byte address field, or the single address byte of a 1-byte address field is compared to two registers. (RAL1, RAL2). Data Sheet 0= RAL2 has been recognized 1= RAL1 has been recognized 309 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Byte Count Low - HDLC Channel 1 (Read) RBCL 7 0 RBC7 RBC0 (66) Together with RBCH, bits RBC(11:8), indicates the length of a received frame (1 to 4095 bytes). Bits RBC(4:0) indicate the number of valid bytes currently in RFIFO. These registers must be read by the CPU following a RME interrupt. Received Byte Count High - HDLC Channel 1 (Read) Value after reset: 000xxxxx 7 0 RBCH OV OV RBC11 RBC10 RBC9 RBC8 (67) Counter Overflow - HDLC Channel 1 More than 4095 bytes received. RBC(11:8) Receive Byte Count - HDLC Channel 1 (most significant bits) Together with RBCL, bits RBC(7:0) indicates the length of the received frame. Interrupt Status Register 0 (Read) Value after reset: 00H 7 ISR0 RME 0 RFS T8MS RMB CASC CRC4 SA6SC RPF (68) All bits are reset when ISR0 is read. If bit GCR.VIS is set, interrupt statuses in ISR0 are flagged although they are masked by register IMR0. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. RME Receive Message End - HDLC Channel 1 One complete message of length less than 32 bytes, or the last part of a frame at least 32 bytes long is stored in the receive FIFO, including the status byte. Data Sheet 310 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers The complete message length can be determined reading the RBCH, RBCL registers, the number of bytes currently stored in RFIFO is given by RBC(4:0). Additional information is available in the RSIS register. RFS Receive Frame Start - HDLC Channel 1 This is an early receiver interrupt activated after the start of a valid frame has been detected, i.e. after an address match (in operation modes providing address recognition), or after the opening flag (transparent mode 0) is detected, delayed by two bytes. After an RFS interrupt, the contents of • RAL1 • RSIS bits 3 to 1 are valid and can be read by the CPU. T8MS Receive Time Out 8 ms Only active if multiframing is enabled. The framer has found the double framing (basic framing) FRS0.LFA = 0 and is searching for the multiframing. This interrupt is set to indicate that no multiframing was found within a time window of 8 ms. In multiframe synchronous state this interrupt is not generated. Refer also to floating multiframe alignment window. RMB Receive Multiframe Begin This bit is set with the beginning of a received CRC multiframe related to the internal receive line timing. In CRC multiframe format FMR2.RFS1 = 1 or in doubleframe format FMR2.RFS(1:0) = 01 this interrupt occurs every 2 ms. If FMR2.RFS(1:0) = 00 this interrupt is generated every doubleframe (512 bits). CASC Data Sheet Received CAS Information Changed This bit is set with the updating of a received CAS multiframe information in the registers RS(16:1). If the last received CAS information is different to the previous received one, this interrupt is generated after update has been completed. This interrupt only occurs only in TS0 and TS16 synchronous state. The registers RS(16:1) should be read within the next 2 ms otherwise the contents is lost. 311 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers CRC4 Receive CRC4 Error 0= No CRC4 error occurs. 1= The CRC4 check of the last received submultiframe failed. Receive Sa6-Bit Status Changed SA6SC With every change of state of the received Sa6-bit combinations this interrupt is set. RPF Receive Pool Full 32 bytes of a frame have arrived in the receive FIFO. The frame is not yet completely received. Interrupt Status Register 1 (Read) 7 ISR1 LLBSC 0 RDO ALLS XDU XMB SUEX XLSC XPR (69) All bits are reset when ISR1 is read. If bit GCR.VIS is set, interrupt statuses in ISR1 are flagged although they are masked by register IMR1. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. LLBSC Line Loop-Back Status Change Depending on bit LCR1.EPRM the source of this interrupt status changed: LCR1.EPRM = 0: This bit is set, if the LLB activate signal or the LLB deactivate signal, respectively, is detected over a period of 25 ms with a bit error rate less than 10-2. The LLBSC bit is also set, if the current detection status is left, i.e., if the bit error rate exceeds 10-2. The actual detection status can be read from the RSP.LLBAD and RSP.LLBDD, respectively. PRBS Status Change LCR1.EPRM = 1: With any change of state of the PRBS synchronizer this bit is set. The current status of the PRBS synchronizer is indicated in RSP.LLBAD. Data Sheet 312 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RDO Receive Data Overflow - HDLC Channel 1 This interrupt status indicates that the CPU did not respond fast enough to an RPF or RME interrupt and that data in RFIFO has been lost. Even when this interrupt status is generated, the frame continues to be received when space in the RFIFO is available again. Note: Whereas the bit RSIS.RDO in the frame status byte indicates whether an overflow occurred when receiving the frame currently accessed in the RFIFO, the ISR1.RDO interrupt status is generated as soon as an overflow occurs and does not necessarily pertain to the frame currently accessed by the processor. ALLS All Sent - HDLC Channel 1 This bit is set if the last bit of the current frame has been sent completely and XFIFO is empty. This bit is valid in HDLC mode only. XDU Transmit Data Underrun - HDLC Channel 1 Transmitted frame was terminated with an abort sequence because no data was available for transmission in XFIFO and no XME was issued. Note: Transmitter and XFIFO are reset and deactivated if this condition occurs. They are reactivated not before this interrupt status register has been read. Thus, XDU should not be masked by register IMR1. XMB Transmit Multiframe Begin This bit is set every 2 ms with the beginning of a transmitted multiframe related to the internal transmit line interface timing. Just before setting this bit registers XS(16:1) are copied in the transmit shift registers. The registers XS(16:1) are empty and has to be updated otherwise the contents is retransmitted. SUEX Signaling Unit Error Threshold Exceeded - HDLC Channel 1 Masks the indication by interrupt that the selected error threshold for SS7 signaling units has been exceeded. 0= Signaling unit error count below selected threshold 1= Signaling unit error count exceeded selected threshold Note: SUEX is only valid, if SS7 mode is selected. If SUEX is caused by an aborted/invalid frame, the interrupt will be issued regularly until a valid frame is received (e.g. a FISU). Data Sheet 313 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XLSC Transmit Line Status Change XLSC is set with the rising edge of the bit FRS1.XLO or with any change of bit FRS1.XLS. The actual status of the transmit line monitor can be read from the FRS1.XLS and FRS1.XLO. XPR Transmit Pool Ready - HDLC Channel 1 A data block of up to 32 bytes can be written to the transmit FIFO. XPR enables the fastest access to XFIFO. It has to be used for transmission of long frames, back-to-back frames or frames with shared flags. Interrupt Status Register 2 (Read) 7 ISR2 FAR 0 LFA MFAR T400MS AIS LOS RAR RA (6A) All bits are reset when ISR2 is read. If bit GCR.VIS is set, interrupt statuses in ISR2 are flagged although they are masked by register IMR2. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. FAR Frame Alignment Recovery The framer has reached doubleframe synchronization. Set when bit FRS0.LFA is reset. It is set also after alarm simulation is finished and the receiver is still synchronous. LFA Loss of Frame Alignment The framer has lost synchronization and bit FRS0.LFA is set. It is set during alarm simulation. MFAR Multiframe Alignment Recovery Set when the framer has found two CRC-multiframes at an interval of n × 2 ms (n = 1, 2, 3, and so forth) without a framing error. At the same time bit FRS0.LMFA is reset. It is set also after alarm simulation is finished and the receiver is still synchronous. Only active if CRC-multiframe format is selected. Data Sheet 314 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers T400MS Receive Time Out 400 ms Only active if multiframing is enabled. The framer has found the doubleframes (basic framing) FRS0.LFA = 0 and is searching for the multiframing. This interrupt is set to indicate that no multiframing was found within a time window of 400 ms after basic framing has been achieved. In multiframe synchronous state this interrupt is not generated. AIS Alarm Indication Signal This bit is set when an alarm indication signal is detected and bit FRS0.AIS is set. It is set during alarm simulation. If GCR.SCI is set high this interrupt status bit is set with every change of state of FRS0.AIS. LOS Loss-of-Signal This bit is set when a loss-of-signal alarm is detected in the received bit stream and FRS0.LOS is set. It is set during alarm simulation. If GCR.SCI is set high this interrupt status bit is set with every change of state of FRS0.LOS. RAR Remote Alarm Recovery Set if a remote alarm in TS0 is cleared and bit FRS0.RRA is reset. It is set also after alarm simulation is finished and no remote alarm is detected. RA Remote Alarm Set if a remote alarm in TS0 is detected and bit FRS0.RRA is set. It is set during alarm simulation. Data Sheet 315 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Interrupt Status Register 3 (Read) 7 ISR3 ES 0 SEC LMFA16 AIS16 RA16 RSN RSP (6B) All bits are reset when ISR3 is read. If bit GCR.VIS is set, interrupt statuses in ISR3 are flagged although they are masked by register IMR3. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. ES Errored Second This bit is set if at least one enabled interrupt source by ESM is set during the time interval of one second. Interrupt sources of ESM register: LFA = Loss of frame alignment detected (FRS0.LFA) FER = Framing error received CER = CRC error received AIS = Alarm indication signal (FRS0.AIS) LOS = Loss-of-signal (FRS0.LOS) CVE = Code violation detected SLIP = Receive Slip positive/negative detected EBE = E-Bit error detected (RSP.RS13/15) SEC Second Timer The internal one-second timer has expired. The timer is derived from clock RCLK or external pin SEC/FSC. LMFA16 Loss of Multiframe Alignment TS 16 Multiframe alignment of time slot 16 has been lost if two consecutive multiframe pattern are not detected or if in 16 consecutive time slot 16 all bits are reset. If register GCR.SCI is high this interrupt status bit is set with every change of state of FRS1.TS16LFA. AIS16 Alarm Indication Signal TS 16 Status Change The alarm indication signal AIS in time slot 16 for the 64 kbit/s channel associated signaling is detected or cleared. A change in bit FRS1.TS16AIS sets this interrupt. (This bit is set if the incoming TS 16 signal contains less than 4 zeros in each of two consecutive TS16multiframe periods.) Data Sheet 316 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RA16 Remote Alarm Time Slot 16 Status Change A change in the remote alarm bit in CAS multiframe alignment word is detected. RSN Receive Slip Negative The frequency of the receive route clock is greater than the frequency of the receive system interface working clock based on 2.048 MHz. A frame is skipped. It is set during alarm simulation. RSP Receive Slip Positive The frequency of the receive route clock is less than the frequency of the receive system interface working clock based on 2.048 MHz. A frame is repeated. It is set during alarm simulation. Interrupt Status Register 4 (Read) 7 ISR4 XSP 0 XSN RME2 RFS2 RDO2 ALLS2 XDU2 RPF2 (6C) All bits are reset when ISR4 is read. If bit GCR.VIS is set, interrupt statuses in ISR4 are flagged although they are masked by register IMR4. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. XSP Transmit Slip Positive The frequency of the transmit clock is less than the frequency of the transmit system interface working clock based on 2.048 MHz. A frame is repeated. After a slip has performed writing of register XC1 is not necessary. XSN Transmit Slip Negative The frequency of the transmit clock is greater than the frequency of the transmit system interface working clock based on 2.048 MHz. A frame is skipped. After a slip has performed writing of register XC1 is not necessary. Data Sheet 317 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RME2 Receive Message End - HDLC Channel 2 One complete message of length less than 32 bytes, or the last part of a frame at least 32 bytes long is stored in the receive FIFO2, including the status byte. The complete message length can be determined reading register RBC2, the number of bytes currently stored in RFIFO2 is given by RBC2(6:0). Additional information is available in register RSIS2. RFS2 Receive Frame Start - HDLC Channel 2 This is an early receiver interrupt activated after the start of a valid frame has been detected, i.e. after an address match (in operation modes providing address recognition), or after the opening flag (transparent mode 0) is detected, delayed by two bytes. After an RFS2 interrupt, the contents of • RAL1 • RSIS2 bits 3 to 1 are valid and can be read by the CPU. RDO2 Receive Data Overflow - HDLC Channel 2 This interrupt status indicates that the CPU did not respond fast enough to an RPF2 or RME2 interrupt and that data in RFIFO2 has been lost. Even when this interrupt status is generated, the frame continues to be received when space in the RFIFO2 is available again. Note: Whereas the bit RSIS2.RDO2 in the frame status byte indicates whether an overflow occurred when receiving the frame currently accessed in the RFIFO2, the ISR4.RDO2 interrupt status is generated as soon as an overflow occurs and does not necessarily pertain to the frame currently accessed by the processor. ALLS2 All Sent - HDLC Channel 2 This bit is set if the last bit of the current frame has been sent completely and XFIFO2 is empty. This bit is valid in HDLC mode only. Data Sheet 318 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XDU2 Transmit Data Underrun - HDLC Channel 2 Transmitted frame was terminated with an abort sequence because no data was available for transmission in XFIFO2 and no XME2 was issued. Note: Transmitter and XFIFO2 are reset and deactivated if this condition occurs. They are reactivated not before this interrupt status register has been read. Thus, XDU2 should not be masked via register IMR4. RPF2 Receive Pool Full - HDLC Channel 2 32 bytes of a frame have arrived in the receive FIFO2. The frame is not yet completely received. Interrupt Status Register 5 (Read) 7 ISR5 XPR2 0 XPR3 RME3 RFS3 RDO3 ALLS3 XDU3 RPF3 (6D) All bits are reset when ISR5 is read. If bit GCR.VIS is set, interrupt statuses in ISR5 are flagged although they are masked via register IMR5. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. XPR2 Transmit Pool Ready - HDLC Channel 2 A data block of up to 32 bytes can be written to the transmit FIFO2. XPR2 enables the fastest access to XFIFO2. It has to be used for transmission of long frames, back-to-back frames or frames with shared flags. XPR3 Transmit Pool Ready - HDLC Channel 3 A data block of up to 32 bytes can be written to the transmit FIFO3. XPR3 enables the fastest access to XFIFO3. It has to be used for transmission of long frames, back-to-back frames or frames with shared flags. Data Sheet 319 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers RME3 Receive Message End - HDLC Channel 3 One complete message of length less than 32 bytes, or the last part of a frame at least 32 bytes long is stored in the receive FIFO3, including the status byte. The complete message length can be determined reading register RBC3, the number of bytes currently stored in RFIFO3 is given by RBC3(6:0). Additional information is available in register RSIS3. RFS3 Receive Frame Start - HDLC Channel 3 This is an early receiver interrupt activated after the start of a valid frame has been detected, i.e. after an address match (in operation modes providing address recognition), or after the opening flag (transparent mode 0) is detected, delayed by two bytes. After an RFS2 interrupt, the contents of • RAL1 • RSIS3 bits 3 to 1 are valid and can be read by the CPU. RDO3 Receive Data Overflow - HDLC Channel 3 This interrupt status indicates that the CPU did not respond fast enough to an RPF3 or RME3 interrupt and that data in RFIFO3 has been lost. Even when this interrupt status is generated, the frame continues to be received when space in the RFIFO3 is available again. Note: Whereas the bit RSIS3.RDO3 in the frame status byte indicates whether an overflow occurred when receiving the frame currently accessed in the RFIFO3, the ISR5.RDO3 interrupt status is generated as soon as an overflow occurs and does not necessarily pertain to the frame currently accessed by the processor. ALLS3 All Sent - HDLC Channel 3 This bit is set if the last bit of the current frame has been sent completely and XFIFO3 is empty. This bit is valid in HDLC mode only. Data Sheet 320 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XDU3 Transmit Data Underrun - HDLC Channel 3 Transmitted frame was terminated with an abort sequence because no data was available for transmission in XFIFO3 and no XME3 was issued. Note: Transmitter and XFIFO3 are reset and deactivated if this condition occurs. They are reactivated not before this interrupt status register has been read. Thus, XDU3 should not be masked via register IMR5. RPF3 Receive Pool Full - HDLC Channel 3 32 bytes of a frame have arrived in the receive FIFO3. The frame is not yet completely received. Global Interrupt Status Register (Read) Value after reset: 00H 7 GIS 0 ISR5 ISR4 ISR3 ISR2 ISR1 ISR0 (6E) This status register points to pending interrupts sourced by ISR(5:0). Data Sheet 321 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive CAS Register (Read) Value after reset: not defined Table 62 Receive CAS Registers (E1) 7 0 RS1 0 0 0 0 X Y X X (70) RS2 A1 B1 C1 D1 A16 B16 C16 D16 (71) RS3 A2 B2 C2 D2 A17 B17 C17 D17 (72) RS4 A3 B3 C3 D3 A18 B18 C18 D18 (73) RS5 A4 B4 C4 D4 A19 B19 C19 D19 (74) RS6 A5 B5 C5 D5 A20 B20 C20 D20 (75) RS7 A6 B6 C6 D6 A21 B21 C21 D21 (76) RS8 A7 B7 C7 D7 A22 B22 C22 D22 (77) RS9 A8 B8 C8 D8 A23 B23 C23 D23 (78) RS10 A9 B9 C9 D9 A24 B24 C24 D24 (79) RS11 A10 B10 C10 D10 A25 B25 C25 D25 (7A) RS12 A11 B11 C11 D11 A26 B26 C26 D26 (7B) RS13 A12 B12 C12 D12 A27 B27 C27 D27 (7C) RS14 A13 B13 C13 D13 A28 B28 C28 D28 (7D) RS15 A14 B14 C14 D14 A29 B29 C29 D29 (7E) RS16 A15 B15 C15 D15 A30 B30 C30 D30 (7F) Receive CAS Register (16:1) Each register except RS1 contains the received CAS bits for two time slots. The received CAS multiframe is compared to the previously received one. If the contents changed a CAS multiframe changed interrupt (ISR0.CASC) is generated and informs the user that a new multiframe has to be read within the next 2 ms. If requests for reading the RS(16:1) register are ignored, the received data is lost. RS1 contains frame 0 of the CAS multiframe. MSB is received first. Additionally a receive signaling data change pointer indicates an update of register RS(16:1). Refer also to register RSP(2:1). Access to RS(16:1) registers is only valid if the serial receive signaling access on the system highway is disabled. Data Sheet 322 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Byte Count Register 2 (Read) Value after reset: 00H 7 RBC2 OV2 OV2 0 RBC26 RBC25 RBC24 RBC23 RBC22 RBC21 RBC20 (90) Counter Overflow - HDLC Channel 2 RBC2(6:0) 0= Less than or equal to 128 bytes received 1= More than 128 bytes received Receive Byte Count - HDLC Channel 2 Indicates the length of a received frame. Receive Byte Count Register 3 (Read) Value after reset: 00H 7 RBC3 OV3 OV3 0 RBC36 RBC35 RBC34 RBC33 RBC32 RBC31 RBC30 (91) Counter Overflow - HDLC Channel 3 RBC3(6:0) 0= Less than or equal to 128 bytes received 1= More than 128 bytes received Receive Byte Count - HDLC Channel 3 Indicates the length of a received frame. Signaling Status Register 2 (Read) Value after reset: 00H 7 SIS2 XDOV2 XDOV2 0 XFW2 XREP2 RLI2 CEC2 (98) Transmit Data Overflow - HDLC Channel 2 More than 32 bytes have been written to the XFIFO2. This bit is reset • by a transmitter reset command XRES or • when all bytes in the accessible half of the XFIFO2 have been moved in the inaccessible half. Data Sheet 323 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XFW2 Transmit FIFO Write Enable - HDLC Channel 2 Data can be written to the XFIFO2. XREP2 Transmission Repeat - HDLC Channel 2 Status indication of CMDR2.XREP2. RLI2 Receive Line Inactive - HDLC Channel 2 Neither flags as interframe time fill nor frames are received via the signaling time slot. CEC2 Command Executing - HDLC Channel 2 0= No command is currently executed, the CMDR3 register can be written to. 1= A command (written previously to CMDR3) is currently executed, no further command can be temporarily written in CMDR3 register. Note: CEC2 will be active at most 2.5 periods of the current system data rate. Data Sheet 324 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive Signaling Status Register 2 (Read) Value after reset: 00H 7 RSIS2 VFR2 0 RDO2 CRC162 RAB2 HA12 HA02 LA2 (99) RSIS2 relates to the last received HDLC channel 2 frame; it is copied into RFIFO2 when end-of-frame is recognized (last byte of each stored frame). VFR2 Valid Frame - HDLC Channel 2 Determines whether a valid frame has been received. 1= Valid 0= Invalid An invalid frame is either – a frame which is not an integer number of 8 bits (n×8 bits) in length (e.g. 25 bits), or – a frame which is too short taking into account the operation mode selected via MODE2 (MDS2(2:0)) and the selection of receive CRC ON/OFF (CCR3.RCRC2) as follows: • MDS2(2:0)=011 (16 bit Address), RCRC2=0: 4 bytes; RCRC2=1: 3 or 4 bytes • MDS2(2:0)=010 (8 bit Address), RCRC2=0: 3 bytes; RCRC2=1: 2 or 3 bytes Note: Shorter frames are not reported. RDO2 Receive Data Overflow - HDLC Channel 2 A data overflow has occurred during reception of the frame. Additionally, an interrupt can be generated (refer to ISR4.RDO2/IMR4.RDO2). CRC162 RAB2 CRC16 Compare/Check - HDLC Channel 2 0= CRC check failed; received frame contains errors. 1= CRC check o.k.; received frame is error-free. Receive Message Aborted - HDLC Channel 2 This bit is set, if more than 5 contiguous 1-bits are detected. Data Sheet 325 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers HA12, HA02 High Byte Address Compare - HDLC Channel 2 Significant only if 2-byte address mode is selected. In operating modes which provide high byte address recognition, the FALC® compares the high byte of a 2-byte address with the contents of two individually programmable registers (RAH1, RAH2) and the fixed values FEH and FCH (broadcast address). Depending on the result of this comparison, the following bit combinations are possible: 00 = RAH2 has been recognized 01 = Broadcast address has been recognized 10 = RAH1 has been recognized C/R=0 (bit 1) 11 = RAH1 has been recognized C/R=1 (bit 1) Note: If RAH1, RAH2 contain identical values, a match is indicated by "10" or "11". LA2 Low Byte Address Compare - HDLC Channel 2 Significant in HDLC modes only. The low byte address of a 2-byte address field, or the single address byte of a 1-byte address field is compared with two registers. (RAL1, RAL2). 0= RAL2 has been recognized 1= RAL1 has been recognized Signaling Status Register 3 (Read) Value after reset: 00H 7 SIS3 XDOV3 XDOV3 0 XFW3 XREP3 RLI3 CEC3 (9A) Transmit Data Overflow - HDLC Channel 3 More than 32 bytes have been written to the XFIFO3. This bit is reset – by a transmitter reset command XRES or – when all bytes in the accessible half of the XFIFO3 have been moved in the inaccessible half. XFW3 Transmit FIFO Write Enable - HDLC Channel 3 Data can be written to the XFIFO3. Data Sheet 326 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers XREP3 Transmission Repeat - HDLC Channel 3 Status indication of CMDR3.XREP3. RLI3 Receive Line Inactive - HDLC Channel 3 Neither flags as interframe time fill nor frames are received via the signaling time slot. CEC3 Command Executing - HDLC Channel 3 0= No command is currently executed, the CMDR4 register can be written to. 1= A command (written previously to CMDR4) is currently executed, no further command can be temporarily written in CMDR4 register. Note: CEC3 will be active up to 2.5 periods of the current system data rate. Receive Signaling Status Register 3 (Read) Value after reset: 00H 7 RSIS3 VFR3 0 RDO3 CRC163 RAB3 HA13 HA03 LA3 (9B) RSIS3 relates to the last received HDLC channel 3 frame; it is copied into RFIFO3 when end-of-frame is recognized (last byte of each stored frame). VFR3 Valid Frame - HDLC Channel 3 Determines whether a valid frame has been received. 1= Valid 0= Invalid An invalid frame is either – a frame which is not an integer number of 8 bits (n×8 bits) in length (e.g. 25 bits), or – a frame which is too short taking into account the operation mode selected via MODE3 (MDS3(2:0)) and the selection of receive CRC ON/OFF (CCR4.RCRC3) as follows: • MDS3(2:0)=011 (16 bit Address), RCRC3=0: 4 bytes; RCRC3=1: 3 or 4 bytes • MDS3(2:0)=010 (8 bit Address), RCRC3=0: 3 bytes; RCRC3=1: 2 or 3 bytes Data Sheet 327 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Note: Shorter frames are not reported. RDO3 Receive Data Overflow - HDLC Channel 3 A data overflow has occurred during reception of the frame. Additionally, an interrupt can be generated (refer to ISR5.RDO3/IMR5.RDO3). CRC163 RAB3 CRC16 Compare/Check - HDLC Channel 3 0= CRC check failed; received frame contains errors. 1= CRC check o.k.; received frame is error-free. Receive Message Aborted - HDLC Channel 3 This bit is set, if more than 5 contiguous 1-bits are detected. HA13, HA03 High Byte Address Compare - HDLC Channel 3 Significant only if 2-byte address mode is selected. In operating modes which provide high byte address recognition, the FALC® compares the high byte of a 2-byte address with the contents of two individually programmable registers (RAH1, RAH2) and the fixed values FEH and FCH (broadcast address). Depending on the result of this comparison, the following bit combinations are possible: 00 = RAH2 has been recognized 01 = Broadcast address has been recognized 10 = RAH1 has been recognized C/R=0 (bit 1) 11 = RAH1 has been recognized C/R=1 (bit 1) Note: If RAH1, RAH2 contain identical values, a match is indicated by "10" or "11". LA3 Low Byte Address Compare - HDLC Channel 3 Significant in HDLC modes only. The low byte address of a 2-byte address field, or the single address byte of a 1-byte address field is compared with two registers. (RAL1, RAL2). 0= 1= Data Sheet RAL2 has been recognized RAL1 has been recognized 328 2002-08-27 FALC56 V1.2 PEB 2256 E1 Registers Receive FIFO 2 (Read) Value after reset: 00H 7 0 RFIFO2 RF7 RF0 (9C) RFIFO2 RF15 RF8 (9D) RF(15:0) Receive FIFO - HDLC Channel 2 The function is equivalent to RFIFO of HDLC channel 1. Receive FIFO 3 (Read) Value after reset: 00H 7 0 RFIFO3 RF7 RF0 (9E) RFIFO3 RF15 RF8 (9F) RF(15:0) Receive FIFO - HDLC Channel 3 The function is equivalent to RFIFO of HDLC channel 1. Identification Register (Read) Value after reset: xxxxxx11 7 WID x 0 x x x x x 1 1 (EC) Additional version identification register. Data Sheet 329 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 10 T1/J1 Registers 10.1 T1/J1 Control Register Addresses Table 63 T1/J1 Control Register Address Arrangement Address Register Type Comment Page 00 XFIFO W Transmit FIFO 334 01 XFIFO W Transmit FIFO 334 02 CMDR W Command Register 334 03 MODE R/W Mode Register 336 04 RAH1 R/W Receive Address High 1 337 05 RAH2 R/W Receive Address High 2 337 06 RAL1 R/W Receive Address Low 1 337 07 RAL2 R/W Receive Address Low 2 337 08 IPC R/W Interrupt Port Configuration 338 09 CCR1 R/W Common Configuration Register 1 338 0A CCR2 R/W Common Configuration Register 2 341 0C RTR1 R/W Receive Time Slot Register 1 342 0D RTR2 R/W Receive Time Slot Register 2 342 0E RTR3 R/W Receive Time Slot Register 3 342 0F RTR4 R/W Receive Time Slot Register 4 342 10 TTR1 R/W Transmit Time Slot Register 1 343 11 TTR2 R/W Transmit Time Slot Register 2 343 12 TTR3 R/W Transmit Time Slot Register 3 343 13 TTR4 R/W Transmit Time Slot Register 4 343 14 IMR0 R/W Interrupt Mask Register 0 344 15 IMR1 R/W Interrupt Mask Register 1 344 16 IMR2 R/W Interrupt Mask Register 2 344 17 IMR3 R/W Interrupt Mask Register 3 344 18 IMR4 R/W Interrupt Mask Register 4 344 19 IMR5 R/W Interrupt Mask Register 5 344 1B IERR R/W Single Bit Error Insertion Register 345 1C FMR0 R/W Framer Mode Register 0 Data Sheet 330 345 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Table 63 T1/J1 Control Register Address Arrangement (cont’d) Address Register Type Comment Page 1D FMR1 R/W Framer Mode Register 1 347 1E FMR2 R/W Framer Mode Register 2 349 1F LOOP R/W Channel Loop-Back 351 20 FMR4 R/W Framer Mode Register 4 352 21 FMR5 R/W Framer Mode Register 5 354 22 XC0 R/W Transmit Control 0 355 23 XC1 R/W Transmit Control 1 356 24 RC0 R/W Receive Control 0 357 25 RC1 R/W Receive Control 1 359 26 XPM0 R/W Transmit Pulse Mask 0 361 27 XPM1 R/W Transmit Pulse Mask 1 361 28 XPM2 R/W Transmit Pulse Mask 2 361 2B IDLE R/W Idle Channel Code 362 2C XDL1 R/W Transmit DL-Bit Register 1 362 2D XDL2 R/W Transmit DL-Bit Register 2 362 2E XDL3 R/W Transmit DL-Bit Register 3 362 2F CCB1 R/W Clear Channel Register 1 363 30 CCB2 R/W Clear Channel Register 2 363 31 CCB3 R/W Clear Channel Register 3 363 32 ICB1 R/W Idle Channel Register 1 364 33 ICB2 R/W Idle Channel Register 2 364 34 ICB3 R/W Idle Channel Register 3 364 36 LIM0 R/W Line Interface Mode 0 364 37 LIM1 R/W Line Interface Mode 1 366 38 PCD R/W Pulse Count Detection 367 39 PCR R/W Pulse Count Recovery 368 3A LIM2 R/W Line Interface Register 2 369 3B LCR1 R/W Loop Code Register 1 370 3C LCR2 R/W Loop Code Register 2 372 3D LCR3 R/W Loop Code Register 3 372 Data Sheet 331 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Table 63 T1/J1 Control Register Address Arrangement (cont’d) Address Register Type Comment Page 3E SIC1 R/W System Interface Control 1 373 3F SIC2 R/W System Interface Control 2 374 40 SIC3 R/W System Interface Control 3 376 44 CMR1 R/W Clock Mode Register 1 378 45 CMR2 R/W Clock Mode Register 2 379 46 GCR R/W Global Configuration Register 1 381 47 ESM R/W Errored Second Mask 382 60 DEC W Disable Error Counter 382 70 XS1 W Transmit Signaling Register 1 383 71 XS2 W Transmit Signaling Register 2 383 72 XS3 W Transmit Signaling Register 3 383 73 XS4 W Transmit Signaling Register 4 383 74 XS5 W Transmit Signaling Register 5 383 75 XS6 W Transmit Signaling Register 6 383 76 XS7 W Transmit Signaling Register 7 383 77 XS8 W Transmit Signaling Register 8 383 78 XS9 W Transmit Signaling Register 9 383 79 XS10 W Transmit Signaling Register 10 383 7A XS11 W Transmit Signaling Register 11 383 7B XS12 W Transmit Signaling Register 12 383 80 PC1 R/W Port Configuration 1 384 81 PC2 R/W Port Configuration 2 384 82 PC3 R/W Port Configuration 3 384 83 PC4 R/W Port Configuration 4 384 84 PC5 R/W Port Configuration 5 386 85 GPC1 R/W Global Port Configuration 1 387 86 PC6 R/W Port Configuration 6 388 x87 CMDR2 W Command Register 2 389 88 CMDR3 W Command Register 3 389 89 CMDR4 W Command Register 4 390 Data Sheet 332 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Table 63 T1/J1 Control Register Address Arrangement (cont’d) Address Register Type Comment Page 8B CCR3 R/W Common Control Register 3 391 8C CCR4 R/W Common Control Register 4 393 x8D CCR5 R/W Common Control Register 5 394 8E MODE2 R/W Mode Register 2 395 8F MODE3 R/W Mode Register 3 396 92 GCM1 R/W Global Counter Mode 1 397 93 GCM2 R/W Global Counter Mode 2 397 94 GCM3 R/W Global Counter Mode 3 398 95 GCM4 R/W Global Counter Mode 4 399 96 GCM5 R/W Global Counter Mode 5 400 97 GCM6 R/W Global Counter Mode 6 400 9C XFIFO2 W Transmit FIFO 2 402 9D XFIFO2 W Transmit FIFO 2 402 9E XFIFO3 W Transmit FIFO 3 402 9F XFIFO3 W Transmit FIFO 3 402 A0 TSEO R/W Time Slot Even/Odd Select 402 A1 TSBS1 R/W Time Slot Bit Select 1 403 A2 TSBS2 R/W Time Slot Bit Select 2 404 A3 TSBS3 R/W Time Slot Bit Select 3 404 A4 TSS2 R/W Time Slot Select 2 405 A5 TSS3 R/W Time Slot Select 2 405 A8 TPC0 R/W Test Pattern Control Register 0 406 After reset all control registers except the XFIFO and XS(12:1) are initialized to defined values. Unused bits have to be cleared. Data Sheet 333 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 10.2 Detailed Description of T1/J1 Control Registers Transmit FIFO - HDLC Channel 1 (Write) 7 0 XFIFO XF7 XF0 (00) XFIFO XF15 XF8 (01) Writing data to XFIFO of HDLC channel 1 can be done in 8-bit (byte) or 16-bit (word) access. The LSB is transmitted first. Up to 32 bytes/16 words of transmit data can be written to the XFIFO following an XPR interrupt. Command Register (Write) Value after reset: 00H 7 CMDR RMC RMC 0 RRES XREP XRES XHF XTF XME SRES (02) Receive Message Complete - HDLC Channel 1 Confirmation from CPU to FALC56 that the current frame or data block has been fetched following an RPF or RME interrupt, thus the occupied space in the RFIFO can be released. If RMC is given while RFIFO is already cleared, the next incoming data block is cleared instantly, although interrupts are generated. RRES Receiver Reset The receive line interface except the clock and data recovery unit (DPLL), the receive framer, the one-second timer and the receive signaling controller are reset. However the contents of the control registers is not deleted. XREP Transmission Repeat - HDLC Channel 1 If XREP is set together with XTF (write 24H to CMDR), the FALC56 repeatedly transmits the contents of the XFIFO (1 to 32 bytes) without HDLC framing fully transparently, i.e. without flag, CRC. The cyclic transmission is stopped with an SRES command or by resetting XREP. Data Sheet 334 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Note: During cyclic transmission the XREP-bit has to be set with every write operation to CMDR. XRES Transmitter Reset The transmit framer and transmit line interface excluding the system clock generator and the pulse shaper are reset. However the contents of the control registers is not deleted. XHF Transmit HDLC Frame - HDLC Channel 1 After having written up to 32 bytes to the XFIFO, this command initiates the transmission of a HDLC frame. XTF Transmit Transparent Frame - HDLC Channel 1 Initiates the transmission of a transparent frame without HDLC framing. XME Transmit Message End - HDLC Channel 1 Indicates that the data block written last to the transmit FIFO completes the current frame. The FALC56 can terminate the transmission operation properly by appending the CRC and the closing flag sequence to the data. SRES Signaling Transmitter Reset - HDLC Channel 1 The transmitter of the signaling controller is reset. XFIFO is cleared of any data and an abort sequence (seven 1s) followed by interframe time fill is transmitted. In response to XRES an XPR interrupt is generated. This command can be used by the CPU to abort a frame currently in transmission. Note: The maximum time between writing to the CMDR register and the execution of the command takes 2.5 periods of the current system data rate. Therefore, if the CPU operates with a very high clock rate in comparison with the FALC56's clock, it is recommended that bit SIS.CEC should be checked before writing to the CMDR register to avoid any loss of commands. Note: If SCLKX is used to clock the transmission path, commands to the HDLC transmitter should only be sent while this clock is available. If SCLKX is missing, the command register is blocked after an HDLC command is given. Data Sheet 335 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Mode Register (Read/Write) Value after reset: 00H 7 MODE MDS(2:0) MDS2 0 MDS1 MDS0 BRAC HRAC DIV (03) Mode Select - HDLC Channel 1 The operating mode of the HDLC controller is selected. 000 = Reserved 001 = Signaling System 7 (SS7) support1) 010 = One-byte address comparison mode (RAL1, 2) 011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2) 100 = No address comparison 101 = One-byte address comparison mode (RAH1, 2) 110 = Reserved 111 = No HDLC framing mode 1 BRAC BOM Receiver Active - HDLC Channel 1 Switches the BOM receiver to operational or inoperational state. HRAC 0= Receiver inactive 1= Receiver active Receiver Active - HDLC Channel 1 Switches the HDLC receiver to operational or inoperational state. DIV 0= Receiver inactive 1= Receiver active Data Inversion - HDLC Channel 1 Setting this bit inverts the internal generated HDLC channel 1 data stream. 1) 0= Normal operation, HDLC data stream not inverted 1= HDLC data stream inverted CCR2.RADD must be set, if SS7 mode is selected Data Sheet 336 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Address Byte High Register 1 (Read/Write) Value after reset: FDH 7 1 RAH1 0 0 (04) In operating modes that provide high byte address recognition, the high byte of the received address is compared to the individually programmable values in RAH1 and RAH2. The address registers are used by all HDLC channels in common. RAH1 Value of the First Individual High Address Byte Bit 1 (C/R-bit) is excluded from address comparison. Receive Address Byte High Register 2 (Read/Write) Value after reset: FFH 7 0 RAH2 (05) RAH2 Value of Second Individual High Address Byte Receive Address Byte Low Register 1 (Read/Write) Value after reset: FFH 7 0 RAL1 (06) RAL1 Value of First Individual Low Address Byte Receive Address Byte Low Register 2 (Read/Write) Value after reset: FFH 7 0 RAL2 RAL2 Data Sheet (07) Value of the second individually programmable low address byte. 337 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Interrupt Port Configuration (Read/Write) Value after reset: 00H 7 0 IPC SSYF IC1 IC0 (08) Unused bits have to be cleared. SSYF Select SYNC Frequency Only applicable in master mode (LIM0.MAS = 1) and bit CMR2.DCF is cleared. IC0, IC1 0= Reference clock on port SYNC is 1.544/2.048 MHz (see LIM1.DCOC) 1= Reference clock on port SYNC is 8 kHz Interrupt Port Configuration These bits define the function of the interrupt output stage (pin INT): IC1 IC0 Function X 0 1 0 1 1 Open drain output Push/pull output, active low Push/pull output, active high Common Configuration Register 1 (Read/Write) Value after reset: 00H 7 CCR1 BRM EDLX 0 BRM EDLX EITS ITF XMFA RFT1 RFT0 (09) BOM Receive Mode - HDLC Channel 1 (significant in BOM mode only) 0= 10-byte packets 1= Continuous reception Enable DL-Bit Access through the Transmit FIFO - HDLC Channel 1 A one in this bit position enables the internal DL-bit access through the receive/transmit FIFO of the signaling controller. FMR1.EDL has to be cleared. Data Sheet 338 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers EITS ITF Enable Internal Time Slot 0 to 31 Signaling - HDLC Channel 1 0= Internal signaling in time slots 0 to 31 defined by registers RTR(4:1) or TTR(4:1) is disabled. 1= Internal signaling in time slots 0 to 31 defined by registers RTR(4:1) or TTR(4:1) is enabled. Interframe Time Fill - HDLC Channel 1 Determines the idle (= no data to be sent) state of the transmit data coming from the signaling controller. XMFA 0= Continuous logical 1 is output 1= Continuous flag sequences are output (01111110 bit patterns) Transmit Multiframe Aligned - HDLC Channel 1 Determines the synchronization between the framer and the corresponding signaling controller. 0= The contents of the XFIFO is transmitted without multiframe alignment. 1= The contents of the XFIFO is transmitted multiframe aligned. If CCR1.EDLXis set, transmission of DL-bits is started in F72 format with frame 26. The first byte in XFIFO is transmitted in the first time slot selected by TTR(4:1) and so on. After receiving a complete multiframe in the time slot mode (RTR(4:1)) an ISR0.RME interrupt is generated, if no HDLC or BOM mode is enabled. In DL-bit access (CCR1.EDLX/ EITS = 10) XMFA is not valid. Note: During the transmission of the XFIFO content, the SYPX or XMFS interval time should not be changed, otherwise the XFIFO data has to be retransmitted. Data Sheet 339 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RFT(1:0) RFIFO Threshold Level - HDLC Channel 1 The size of the accessible part of RFIFO can be determined by programming these bits. The number of valid bytes after an RPF interrupt is given in the following table: RFT1 RFT0 Size of Accessible Part of RFIFO 0 0 1 1 0 1 0 1 32 bytes (reset value) 16 bytes 4 bytes 2 bytes The value of RFT 1,0 can be changed dynamically – If reception is not running or – after the current data block has been read, but before the command CMDR.RMC is issued (interrupt controlled data transfer). Note: It is seen that changing the value of RFT1,0 is possible even during the reception of one frame. The total length of the received frame can be always read directly in RBCL, RBCH after an RPF interrupt, except when the threshold is increased during reception of that frame. The real length can then be inferred by noting which bit positions in RBCL are reset by an RMC command (see table below): Data Sheet RFT1 RFT0 Bit Positions in RBCL Reset by a CMDR.RMC Command 0 0 1 1 0 1 0 1 RBC(4:0) RBC(3:0) RBC(1:0) RBC0 340 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Common Configuration Register 2 (Read/Write) Value after reset: 00H 7 0 CCR2 RADD RBFE RCRC XCRC (0A) Unused bits have to be cleared. RADD Receive Address Pushed to RFIFO - HDLC Channel 1 If this bit is set, the received HDLC address information (1 or 2 bytes, depending on the address mode selected by MODE.MDS0) is pushed to RFIFO. This function is applicable in non-auto mode and transparent mode 1. RADD must be set, if SS7 mode is selected. RBFE Receive BOM Filter Enable - HDLC Channel 1 Setting this bit the bit oriented message (BOM) receiver only accepts BOM frames after detecting 7 out of 10 equal BOM pattern. The BOM pattern is stored in the RFIFO adding a receive status byte marking a BOM frame (RSIS.HFR) and an interrupt ISR0.RME is generated. The current state of the BOM receiver is indicated in register SIS.IVB. When the valid BOM pattern disappears an interrupt ISR0.BIV is generated. RCRC Receive CRC on/off - HDLC Channel 1 Only applicable in non-auto mode. If this bit is set, the received CRC checksum is written to RFIFO (CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in the received frame, is followed in the RFIFO by the status information byte (contents of register RSIS). The received CRC checksum is additionally checked for correctness. If non-auto mode is selected, the limits for “valid frame” check are modified (refer to RSIS.VFR). XCRC Transmit CRC on/off - HDLC Channel 1 If this bit is set, the CRC checksum is not generated internally. It has to be written as the last two bytes in the transmit FIFO (XFIFO). The transmitted frame is closed automatically with a closing flag. Note: The FALC56 does not check whether the length of the frame, i.e., the number of bytes to be transmitted, makes sense or not. Data Sheet 341 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Time Slot Register 1 to 4 (Read/Write) Value after reset: 00H, 00H, 00H, 00H 7 0 RTR1 TS0 TS1 TS2 TS3 TS4 TS5 TS6 TS7 (0C) RTR2 TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15 (0D) RTR3 TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23 (0E) RTR4 TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 (0F) TS(31:0) Time Slot Register These bits define the received time slots on the system highway port RDO to be extracted. Additionally these registers control the RSIGM marker which can be forced high during the corresponding time slots independently of bit CCR1.EITS. A one in the RTR(4:1) bits samples the corresponding time slot in the RFIFO of the signaling controller, if bit CCR1.EITS is set. Assignments: SIC2.SSC2 = 0: (32 time slots/frame) TS0 → time slot 0,TS31 → time slot 31 SIC2.SSC2 = 1: (24 time slots/frame) TS0 → time slot 0,TS23 → time slot 23 Data Sheet 0= The corresponding time slot is not extracted and stored in the RFIFO. 1= The contents of the selected time slot is stored in the RFIFO. Although the idle time slots can be selected. This function is only active, if bits CCR1.EITS is set. The corresponding time slot is forced high on pin RSIGM. 342 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Transmit Time Slot Register 1 to 4 (Read/Write) Value after reset: 00H, 00H, 00H, 00H 7 0 TTR1 TS0 TS1 TS2 TS3 TS4 TS5 TS6 TS7 (10) TTR2 TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15 (11) TTR3 TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23 (12) TTR4 TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 (13) TS(31:0) Transmit Time Slot Register These bits define the transmit time slots on the system highway to be inserted. Additionally these registers control the XSIGM marker which can be forced high during the corresponding time slots independently of bit CCR1.EITS. A one in the TTR(4:1) bits inserts the corresponding time slot sourced by the XFIFO in the data received on pin XDI, if bit CCR1.EITS is set. If SIC3.TTRF is set and CCR1.EDLX/EITS = 00, insertion of data received on port XSIG is controlled by this registers. Assignments: SIC2.SSC2 = 0: (32 time slots/frame) TS0 → time slot 0, TS31 → time slot 31 SIC2.SSC2 = 1: (24 time slots/frame) TS0 → time slot 0, TS23 → time slot 23 Data Sheet 0= The selected time slot is not inserted into the outgoing data stream. 1= The contents of the selected time slot is inserted into the outgoing data stream from XFIFO. This function is only active, if bits CCR1.EITS is set. The corresponding time slot are forced high on marker pin XSIGM. 343 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Interrupt Mask Registers Value after reset: FFH, FFH, FFH, FFH,FFH 7 0 IMR0 RME RFS ISF RMB RSC CRC6 PDEN RPF (14) IMR1 CASE RDO ALLS XDU XMB SUEX XLSC XPR (15) IMR2 FAR LFA MFAR LMFA AIS LOS RAR RA (16) IMR3 ES SEC RSN RSP (17) IMR4 XSP XSN RME2 RFS2 RDO2 ALLS2 XDU2 RPF2 (18) IMR5 XPR2 XPR3 RME3 RFS3 RDO3 ALLS3 XDU3 RPF3 (19) IMR(5:0) LLBSC Interrupt Mask Register Each interrupt source can generate an interrupt signal on port INT (characteristics of the output stage are defined by register IPC). A “1” in a bit position of IMR(5:0) sets the mask active for the interrupt status in ISR(5:0). Masked interrupt statuses neither generate a signal on INT, nor are they visible in register GIS. Moreover, they are – not displayed in the Interrupt Status Register if bit GCR.VIS is cleared – displayed in the Interrupt Status Register if bit GCR.VIS is set After reset, all interrupts are disabled. Data Sheet 344 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Single Bit Defect Insertion Register (Read/Write) Value after reset: 00H IERR IFASE IMFE ICRCE ICASE IPE IBV (1B) After setting the corresponding bit, the selected defect is inserted into the transmit data stream at the next possible position. After defect insertion is completed, the bit is reset automatically. IFASE Insert single FAS defect IMFE Insert single multiframe defect ICRCE Insert single CRC defect ICASE Insert single CAS defect IPE Insert single PRBS defect IBV Insert bipolar violation Note: Except for CRC defects, CRC checksum calculation is done after defect insertion. Framer Mode Register 0 (Read/Write) Value after reset: 00H 7 FMR0 XC(1:0) XC1 0 XC0 RC1 RC0 FRS SRAF EXLS SIM (1C) Transmit Code Serial line code for the transmitter, independent of the receiver. 00 = NRZ (optical interface) 01 = CMI (1T2B+B8ZS), (optical interface) 10 = AMI coding with Zero Code Suppression (ZCS, B7-stuffing). Disabling of the ZCS is done by activating the clear channel mode by register CCB(3:1). (ternary or digital interface) 11 = B8ZS Code (ternary or digital dual-rail interface). After changing XC(1:0), a transmitter software reset is required (CMDR.XRES = 1). RC(1:0) Receive Code Serial code receiver is independent to the transmitter. Data Sheet 345 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 00 = NRZ (optical interface) 01 = CMI (1T2B+B8ZS), (optical interface) 10 = AMI coding with Zero Code Suppression (ZCS, B7-stuffing), (ternary or digital dual-rail interface) 11 = B8ZS Code (ternary or digital dual-rail interface) After changing RC(1:0), a receiver software reset is required (CMDR.RRES = 1). FRS Force Resynchronization A transition from low to high forces the frame aligner to execute a resynchronization of the pulse frame. In the asynchronous state, a new frame position is assumed at the next candidate if there is one. Otherwise, a new frame search with the meaning of a general reset is started. In the synchronous state this bit has the same meaning as bit FMR0.EXLS except if FMR2.MCSP = 1. SRAF EXLS Select Remote (Yellow) Alarm Format for F12 and ESF Format 0= F12: bit2 = 0 in every channel. ESF: pattern “1111 1111 0000 0000” in data link channel. 1= F12: FS-bit of frame 12. ESF: bit2 = 0 in every channel External Loss Of Frame With a low to high transition a new frame search is started. This has the meaning of a general reset of the internal frame alignment unit. Synchronous state is reached only if there is one definite framing candidate. In the case of multiple candidates, the setting of the bit FMR0.FRS forces the receiver to lock onto the next available framing position. SIM Alarm Simulation Setting/resetting this bit initiates internal error simulation of: AIS (blue alarm), loss-of-signal (red alarm), loss of frame alignment, remote (yellow) alarm, slip, framing errors, CRC errors, code violations. The error counters FEC, CVC, CEC, EBC are incremented. The selection of simulated alarms is done by the error simulation counter: FRS2.ESC(2:0) which is incremented with each setting of bit FMR0.SIM. For complete checking of the alarm indications eight simulation steps are necessary (FRS2.ESC(2:0) = 0 after a complete simulation). SIM has to be held stable at high or low level for at least one receive clock period before changing it again. Data Sheet 346 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Mode Register 1 (Read/Write) Value after reset: 00H 7 FMR1 CTM 0 CTM EDL PMOD CRC ECM SSD0 XAIS (1D) Channel Translation Mode 0= Channel translation mode 0 1= Channel translation mode 1 The different channel translation modes are described in Table 30 on page 131. EDL Enable DL-Bit Access through Register XDL(3:1) Only applicable in F4, F24 or F72 frame format. PMOD 0= Normal operation. The DL-bits are taken from system highway or if enabled by CCR1.EDLX from the XFIFO of the signaling controller. 1= DL-bit register access. The DL-bit information are taken from the registers XDL(3:1) and overwrite the DL-bits received on the system highway (pin XDI) or from the internal XFIFO of the signaling controller. However, transmission of the contents of registers XDL(3:1) is disabled if transparent mode is enabled (FMR4.TM). PCM Mode For E1 application this bit must be set low. Switching from E1 to T1 or vice versa the device needs up to 20 µs to settle up to the internal clocking. CRC 0= PCM 30 or E1 mode. 1= PCM 24 or T1/J1 mode (see RC0.SJR for T1/J1 selection). Enable CRC6 This bit is only significant when using the ESF format. Data Sheet 0= CRC6 check/generation disabled. For transmit direction, all CRC bit positions are set. 1= CRC6 check/generation enabled. 347 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers ECM Error Counter Mode The function of the error counters (FEC,CEC,CVC,EBC) is determined by this bit. SSD0 0= Before reading an error counter the corresponding bit in the Disable Error Counter register (DEC) has to be set. In 8 bit access the low byte of the error counter should always be read before the high byte. The error counters are reset with the rising edge of the corresponding bits in the DEC register. 1= Every second the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Reading the error counter during updating should be avoided (do not access an error counter within 1 µs after the one-second interrupt occurs). Select System Date Rate 0 SIC1.SSD1, FMR1.SSD0 and SIC2.SSC2 define the data rate on the system highway. Programming SSD1/SSD0 and corresponding data rate is shown below. SIC2.SSC2 = 0: 00 = 2.048 Mbit/s 01 = 4.096 Mbit/s 10 = 8.192 Mbit/s 11 = 16.384 Mbit/s SIC2.SSC2 = 1: XAIS 00 = 1.544 Mbit/s 01 = 3.088 Mbit/s 10 = 6.176 Mbit/s 11 = 12.352 Mbit/s Transmit AIS Towards Remote End Sends AIS (blue alarm) on ports XL1, XL2 towards the remote end. If Local Loop Mode is enabled the transmitted data is looped back to the system internal highway without any changes. Data Sheet 348 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Mode Register 2 (Read/Write) Value after reset: 00H 7 0 FMR2 MCSP SSP DAIS SAIS PLB AXRA EXZE MCSP Multiple Candidates Synchronization Procedure SSP Select Synchronization/Resynchronization Procedure (1E) Together with bit FMR2.SSP the synchronization mode of the receive framer is defined: MCSP/SSP: 00 = F12/F72 format: Specified number of errors in both FT framing and FS framing lead to loss of sync (FRS0.LFA is set). In the case of FS-bit framing errors, bit FRS0.LMFA is set additionally. A complete new synchronization procedure is initiated to regain pulseframe alignment and then multiframe alignment. F24: normal operation: synchronization is achieved only on verification the framing pattern. 01 = F12/F72: Specified number of errors in FT framing has the same effect as above. Specified number of errors in FS framing only initiates a new search for multiframe alignment without influencing pulseframe synchronous state (FRS0.LMFA is set). F24: Synchronous state is reached when three consecutive multiframe pattern are correctly found independent of the occurrence of CRC6 errors. 10 = F12/F24: A one enables a synchronization mode which is able to choose multiple framing pattern candidates step by step. I.e. if in synchronous state the CRC error counter indicates that the synchronization might have been based on an alias framing pattern, setting of FMR0.FRS leads to synchronization on the next candidate available. However, only the previously assumed candidate is discarded in the internal framing pattern memory. The latter procedure can be repeated until the framer locks on the right pattern (no extensive CRC errors). Therefore bit FMR1.CRC must be set. Data Sheet 349 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 11 = F24: Synchronization is achieved on verification the framing pattern and the CRC6 bits. Synchronous state is reached when framing pattern and CRC6 checksum are correctly found. For correct operation the CRC check must be enabled by setting bit FMR1.CRC. DAIS SAIS Disable AIS to System Interface 0= AIS is automatically inserted into the data stream to RDO if FALC56 is in asynchronous state. 1= Automatic AIS insertion is disabled. Furthermore, AIS insertion can be initiated by programming bit FMR2.SAIS. Send AIS Towards System Interface Sends AIS (blue alarm) on output RDO towards system interface. This function is not influenced by bit FMR2.DAIS. PLB AXRA Data Sheet Payload Loop-Back 0= Normal operation. Payload loop is disabled. 1= The payload loop-back loops the data stream from the receiver section back to transmitter section. Looped data is output on pin RDO. Data received on port XDI, XSIG, SYPX and XMFS is ignored. With FMR4.TM = 1 all 193 bits per frame are looped back. If FMR4.TM = 0 the DL- or FS- or CRC-bits are generated internally. AIS is sent immediately on port RDO by setting the FMR2.SAIS bit. During payload loop is active the receive time slot offset (registers RC(1:0)) should not be changed. It is recommended to write the actual value of XC1 into this register once again, because a write access to register XC1 sets the read/write pointer of the transmit elastic buffer into its optimal position to ensure a maximum wander compensation (the write operation forces a slip). Automatic Transmit Remote Alarm 0= Normal operation 1= The remote alarm (yellow alarm) bit is set automatically in the outgoing data stream if the receiver is in asynchronous state (FRS0.LFA bit is set). In synchronous state the remote alarm bit is reset. 350 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers EXZE Excessive Zeros Detection Enable Selects error detection mode in the bipolar receive bit stream. 0= Only bipolar violations are detected. 1= Bipolar violations and zero strings of 8 or more contiguous zeros in B8ZS code or more than 15 contiguous zeros in AMI code are detected additionally and counted in the code violation counter CVC. LOOP (Read/Write) Value after reset: 00H 7 LOOP RTM 0 RTM ECLB CLA4 CLA3 CLA2 CLA1 CLA0 (1F) Receive Transparent Mode Setting this bit disconnects control of the internal elastic store from the receiver. The elastic store is now in a “free running” mode without any possibility to actualize the time slot assignment to a new frame position in case of resynchronization of the receiver. This function can be used together with the “disable AIS to system interface” feature (FMR2.DAIS) to realize undisturbed transparent reception. This bit should be enabled in case of unframed data reception mode. ECLB Enable Channel Loop-Back 0= Disables the channel loop-back. 1= Enables the channel loop-back selected by this register. Note: CAS-BR must be switched off (FMR5.EIBR = 0) while channel loop back is enabled. CLA(4:0) Channel Address For Loop-Back CLA = 1 to 24 selects the channel. During loop-back, the contents of the associated outgoing channel on ports XL1/XDOP/XOID and XL2/XDON is equal to the idle channel code programmed in register IDLE. Data Sheet 351 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Mode Register 4 (Read/Write) Value after reset: 00H 7 FMR4 AIS3 AIS3 0 TM XRA SSC1 SSC0 AUTO FM1 FM0 (20) Select AIS Condition 0= AIS (blue alarm) is indicated (FRS0.AIS) when two or less zeros in the received bit stream are detected in a time interval of 12 frames (F4, F12, F72) or 24 frames (ESF). 1= AIS (blue alarm) detection is only enabled when FALC56 is in asynchronous state. The alarm is indicated (FRS0.AIS) when – three or less zeros within a time interval of 12 frames (F4, F12, F72), or – five or less zeros within a time interval of 24 frames (ESF) are detected in the received bit stream. TM Transparent Mode Setting this bit enables the transparent mode: In transmit direction bit 8 of every FS/DL time slot from the system internal highway (XDI) is inserted in the F-bit position of the outgoing frame. Internal framing generation, insertion of CRC and DL data is disabled. XRA Transmit Remote Alarm (Yellow Alarm) If high, remote alarm is sent on the PCM route. Clearing the bit removes the remote alarm pattern. Remote alarm indication depends on the multiframe structure as follows: F4: Bit2 = 0 in every speech channel F12: – FMR0.SRAF = 0: bit2 = 0 in every speech channel – FMR0.SRAF = 1: FS-bit of frame 12 is forced to “1” ESF: – FMR0.SRAF = 0: pattern “1111111100000000 11111111000” in data link channel – FMR0.SRAF = 1: bit2 = 0 in every speech channel F72: Bit2 = 0 in every speech channel Data Sheet 352 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers SSC(1:0) Select Sync Conditions Loss of Frame Alignment (FRS0.LFA or opt. FRS0.LMFA) is declared if: 00 = 2 out of 4 framing bits 01 = 2 out of 5 framing bits 10 = 2 out of 6 framing bits in F4/12/72 format 10 = 2 out of 6 framing bits per multiframe period in ESF format 11 = 4 consecutive multiframe pattern in ESF format are incorrect. It depends on the selected multiframe format and optionally on bit FMR2.SSP which framing bits are observed: F4: FT-bits → FRS0.LFA F12, F72:SSP = 0: FT-bits→ FRS0.LFA FS-bits → FRS0.LFA and FRS0.LMFA F12, F72:SSP = 1: FT → FRS0.LFA FS → FRS0.LMFA ESF: ESF framing bits → FRS0.LFA AUTO FM(1:0) Enable Auto Resynchronization 0= The receiver does not re synchronize automatically. Starting a new synchronization procedure is possible by the bits FMR0.EXLS or FMR0.FRS. 1= Auto-resynchronization is enabled. Select Frame Mode FM = 0: 12-frame multiframe format (F12, D3/4) FM = 1: 4-frame multiframe format (F4) FM = 2: 24-frame multiframe format (ESF) FM = 3: 72-frame multiframe format (F72, remote switch mode) Data Sheet 353 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Mode Register 5 (Read/Write) Value after reset: 00H 7 FMR5 EIBR XLD XLU XTM 0 EIBR XLD XLU XTM SSC2 (21) Enable Internal Bit Robbing Access 0= Normal operation. 1= A one in this bit position causes the transmitter to send the bit robbing signaling information stored in the XS(12:1) (ESF, F12, 72) registers or serial CAS in the corresponding time slots. Transmit Line Loop-Back (LLB) Down Code 0= Normal operation. 1= A one in this bit position causes the transmitter to replace normal transmit data with the LLB down (deactivate) Code continuously until this bit is reset. The LLB down code is overwritten by the framing/DL/CRC bits optionally. Transmit LLB Up Code 0= Normal operation. 1= A one in this bit position causes the transmitter to replace normal transmit data with the LLB up (activate) code continuously until this bit is reset. The LLB up code is optionally overwritten by the framing/DL/CRC bits. For proper operation bit FMR5.XLD must be cleared. Transmit Transparent Mode 0 =Ports SYPX/XMFS define the frame/multiframe begin on the transmit system highway. The transmitter is usually synchronized on this externally sourced frame boundary and generates the FS/DL-bits according to this framing. Any change of the transmit time slot assignment subsequently produces a change of the FS/DL-bit positions. 1= Data Sheet Disconnects the control of the transmit system interface from the transmitter. The transmitter is now in a free running mode without any possibility to actualize the multiframe position. The framing (FS/DL-bits) generated by the transmitter are not “disturbed“ (in case of changing the transmit time slot assignment) by the transmit system highway unless register XC1 is written. This bit should be set if loop-timed application is 354 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers selected. For proper operation the transmit elastic buffer (2 frames, SIC1.XBS(1:0) = 10) has to be enabled. SSC2 Select Sync Conditions Only valid in ESF framing format. Loss of Frame Alignment FRS0.LFA is declared if more than 320 CRC6 errors per second interval are detected. Transmit Control 0 (Read/Write) Value after reset: 00H 7 XC0 BRM BRM 0 MFBS BRFO XCO10 XCO9 XCO8 (22) Enable Bit Robbing Marker A one in this bit marks the robbed bit positions on the system highway. RSIGM marks the receive and XSIGM marks the transmit robbed bits. MFBS Enable pure Multiframe Begin Signals Only valid if ESF or F72 format is selected. BRFO 0= RMFB marks the beginning of every received superframe. Additional pulses are provided every 12 frames when using ESF/F24 or F72 format. 1= RMFB marks the beginning of every received multiframe. Bit Robbing Force One Setting this bit forces the robbed bits high transmitted on port RDO. The received signaling data stream for the signaling controller is not influenced by this bit. XCO(10:8) Transmit Offset Initial value loaded into the transmit bit counter at the trigger edge of SCLKX when the synchronous pulse on port SYPX or XMFS is active Refer to register XC1. Data Sheet 355 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Transmit Control 1 (Read/Write) Value after reset: 9CH XC1 7 0 XCO7 XCO0 (23) A write access to this address resets the transmit elastic buffer to its basic starting position. Therefore, updating the value should only be done when the FALC56 is initialized or when the buffer should be centered. As a consequence a transmit slip will occur. XCO(7:0) Transmit Offset Initial value loaded into the transmit bit counter at the trigger edge of SCLKX when the synchronous pulse on port SYPX/XMFS is active. Calculation of delay time T (SCLKX cycles) depends on the value X of the transmit offset register XC(1:0): system clocking rate: modulo 2.048 MHz (SIC2.SSC2 = 0) 0 ≤ T ≤ 4: X = 4 - T 5 ≤ T ≤ maximum delay:X = 256 × SC/SD - T + 4) with maximum delay = (256 × SC/SD) -1 with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2 with SD = 2.048 Mbit/s (system clocking n × 2.048 MHz) or system clocking rate: modulo 1.544 MHz (SIC2.SSC2 = 1) 0 ≤ T ≤ 4: X = 3 - T + 7 × SC/BF 5 ≤ T ≤ maximum delay:X = 200 × SC/BF - T + 3 with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2 SD = 1.544 Mbit/s (system clocking n × 1.544 MHz) with BF = basic frequency = 1.544 MHz T = Time between the active edge of SCLKX after SYPX pulse begin and beginning of the next frame (F-bit, channel phase 0), measured in number of SCLKX clock intervals; maximum delay: Tmax = (200 × SC/BF) - (7 × SC/BF) - 1 See page 178 for further description. Data Sheet 356 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Control 0 (Read/Write) Value after reset: 00H 7 RC0 SJR RRAM SJR 0 RRAM CRCI XCRCI RDIS RCO10 RCO9 RCO8 (24) Select Japanese ITU-T Requirements 0= T1: Alarm handling is done according ITU-T G. 704+706 1= J1: Alarm handling is done according ITU-T JG. 704+706 Receive Remote Alarm Mode The conditions for remote (yellow) alarm (FRS0.RRA) detection can be selected by this bit to allow detection even in the presence of a bit error rate of up to 10-3: RRAM = 0 Detection F4: Bit2 = 0 in every speech channel per frame. F12: – FMR0.SRAF = 0: bit2 = 0 in every speech channel per frame. – FMR0.SRAF = 1: S-bit of frame 12 is forced to “1” ESF: – FMR0.SRAF = 0: pattern “1111 1111 0000 0000” in data link channel – FMR0.SRAF = 1: bit2 = 0 in every speech channel F72: Bit2 = 0 in every speech channel per frame. Release: The alarm is reset when above conditions are no longer detected. RRAM = 1 (bit error rate 10-3) Detection F4: Bit2 = 0 in 255 consecutive speech channels. F12: – FMR0.SRAF = 0: bit 2 = 0 in 255 consecutive speech channels. – FMR0.SRAF = 1: S-bit of frame 12 is forced to “1” ESF: – FMR0.SRAF = 0: pattern “1111 1111 0000 0000” in data link channel – FMR0.SRAF = 1: bit 2 = 0 in 255 consecutive speech channels F72: Bit 2 = 0 in 255 consecutive speech channels. Data Sheet 357 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Release Depending on the selected multiframe format the alarm is reset when FALC56 does not detect – the “bit 2 = 0" condition for three consecutive pulse frames (all formats if selected), – the "FS-bit" condition for three consecutive multiframes (F12), – the "DL pattern" for three times in a row (ESF). CRCI Automatic CRC6 Bit Inversion If set, all CRC bits of one outgoing extended multiframe are inverted in case a CRC error is flagged for the previous received multiframe. This function is logically ored with RC0.XCRCI. XCRCI Transmit CRC6 Bit Inversion If set, the CRC bits in the outgoing data stream are inverted before transmission. This function is logically ored with RC0.CRCI. RDIS Receive Data Input Sense Digital interface, dual-rail: 0= Inputs RDIP/RDIN are active low 1= Inputs RDIP/RDIN are active high Digital Interface, CMI: RCO(10:8) 0= Input ROID is active high 1= Input ROID is active low Receive Offset/Receive Frame Marker Offset Depending on the RP(A to D) pin function different offsets can be programmed. The SYPR and the RFM pin function cannot be selected in parallel. Receive Offset (PC(4:1).RPC(2:0) = 000) Initial value loaded into the receive bit counter at the trigger edge of SCLKR when the synchronous pulse on port SYPR is active. Calculation of delay time T (SCLKR cycles) depends on the value X of the receive offset register RC(1:0). Refer to register RC1. Data Sheet 358 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Control 1 (Read/Write) Value after reset: 9CH 7 RC1 RCO(7:0) RCO7 0 RCO5 RCO0 (25) Receive Offset/Receive Frame Marker Offset Depending on the RP(A to D) pin function different offsets can be programmed. The SYPR and the RFM pin function cannot be selected in parallel. Receive Offset (PC(4:1).RPC(2:0) = 000) Initial value loaded into the receive bit counter at the trigger edge of SCLKR when the synchronous pulse on port SYPR is active. Calculation of delay time T (SCLKR cycles) depends on the value X of the receive offset register RC(1:0): system clocking rate: modulo 2.048 MHz (SIC2.SSC2 = 0) 0 ≤ T ≤ 4:X = 4 - T 5 ≤ T ≤ maximum delay:X = 2052 - T with maximum delay = (256×SC/SD) -1 with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2 with SD = system data rate or system clocking rate: modulo 1.544 MHz (SIC2.SSC2 = 1) 0 ≤ T ≤ 4:X = 4 - T + (7 × SC/SD) 5 ≤ T ≤ maximum delay :X = (200 × SC/SD) + 4 - T with maximum delay = 193×SC/SD - 1 with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2 with SD = system data rate Delay time T = time between beginning of time slot 0 at RDO and the initial edge of SCLKR after SYPR goes active. See page 168 for further description. Data Sheet 359 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Frame Marker Offset (PC(4:1).RPC(2:0) = 001B) Offset programming of the receive frame marker which is output on multifunction port RFM. The receive frame marker can be activated during any bit position of the entire frame and depends on the selected system clock rate. Calculation of the value X of the receive offset register RC(1:0) depends on the bit position which should be marked at marker position MP: system clocking rate: modulo 2.048 MHz (SIC2.SSC2 = 0) 0 ≤ MP ≤ 2045:X = MP + 2 2046 ≤ MP ≤ 2047:X = MP - 2046) e.g: 2.048 MHz: MP = 0 to 255; 4.096 MHz: MP = 0 to 511, 8.192 MHz: MP = 0 to 1023, 16.384 MHz: MP = 0 to 2047 system clocking rate: modulo 1.544 MHz (SIC2.SSC2 = 1) 0 ≤ MP ≤ 193 × (SC/SD) - 3:X = MP + 2 + 7 × SC/SD 193 × (SC/SD) -2 ≤ MP ≤ maximum delay:X = MP + 2 - 186 × SC/ SD with maximum delay = 193×SC/SD - 1 with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2 with SD = system data rate Data Sheet 360 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Transmit Pulse-Mask Registers (Read/Write) Value after reset: 7BH, 03H, 40H 7 0 XPM0 XP12 XP11 XP10 XP04 XP03 XP02 XP01 XP00 (26) XPM1 XP30 XP24 XP23 XP22 XP21 XP20 XP14 XP13 (27) XPM2 0 XLT DAXLT XP34 XP33 XP32 XP31 (28) The transmit pulse shape which is defined in ANSI T1.102 is output on pins XL1 and XL2. The level of the pulse shape can be programmed by registers XPM(2:0) to create a custom waveform. In order to get an optimized pulse shape for the external transformers each pulse shape is internally divided into four sub pulse shapes. In each sub pulse shape a programmed 5 bit value defines the level of the analog voltage on pins XL1/2. Together four 5 bit values have to be programmed to form one complete transmit pulse shape.The four 5 bit values are sent in the following sequence: XP04 to 00: XP14 to 10: XP24 to 20: XP34 to 30: First pulse shape level Second pulse shape level Third pulse shape level Fourth pulse shape level Changing the LSB of each subpulse in registers XPM(2:0) changes the amplitude of the differential voltage on XL1/2 by approximately 80 mV. The XPM values in the following table are based on simulations. They are valid for the following external circuitry: transformer ratio 1:2.4, cable PULB 22AWG (100Ω), serial resistors 2Ω. Adjustment of these coefficients can be necessary for other external conditions. Table 64 Range in m Pulse Shaper Programming (T1/J1) Range in ft. XPM0 XPM1 XPM2 XP04- XP14XP00 XP10 hexadecimal XP24XP20 XP34XP30 decimal 0 to 40 0 to 133 D7 22 1 23 22 8 2 40 to 81 133 to 266 FA 26 1 26 23 9 2 81 to 122 266 to 399 3D 37 1 29 25 13 2 122 to 162 399 to 533 5F 3F 1 31 26 15 2 162 to 200 533 to 655 3F CB 1 31 25 18 3 Data Sheet 361 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XLT Transmit Line Tristate DAXLT 0= Normal operation 1= Transmit line XL1/XL2 or XDOP/XDON are switched into highimpedance state. If this bit is set the transmit line monitor status information is frozen (default value after hardware reset). Disable Automatic Tristating of XL1/2 0= Normal operation. If a short is detected on pins XL1/2 the transmit line monitor sets the XL1/2 outputs into a highimpedance state. 1= If a short is detected on pins XL1/2, the automatic setting of these pins into a high-impedance state (by the XL-monitor) is disabled. Idle Channel Code Register (Read/Write) Value after reset: 00H IDLE 7 0 IDL7 IDL0 IDL(7:0) (2B) Idle Channel Code If channel loop-back is enabled by programming the register LOOP.ECLB = 1, the contents of the assigned outgoing channel on ports XL1/XL2 or XDOP/XDON is set equal to the idle channel code selected by this register. Additionally, the specified pattern overwrites the contents of all channels of the outgoing PCM frame selected by the idle channel registers ICB(3:1). IDL7 is transmitted first. Transmit DL-Bit Register 1-3 (Read/Write) Value after reset: 00H, 00H, 00H 7 0 XDL1 XDL17 XDL16 XDL15 XDL14 XDL13 XDL12 XDL11 XDL10 (2C) XDL2 XDL27 XDL26 XDL25 XDL24 XDL23 XDL22 XDL21 XDL20 (2D) XDL3 XDL37 XDL36 XDL35 XDL34 XDL33 XDL32 XDL31 XDL30 (2E) Data Sheet 362 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XDL(3:1) Transmit FS/DL-Bit Data The DL-bit register access is enabled by setting bits FMR1.EDL = 1. With the transmit multiframe begin an interrupt ISR1.XMB is generated and the contents of these registers XDL(3:1) is copied into a shadow register. The contents is subsequently sent out in the data stream of the next outgoing multiframe if no transparent mode is enabled. XDL10 is sent out first. In F4 frame format only XDL10+XDL11 are transmitted. In F24 frame format XDL10 to 23 are shifted out. In F72 frame format XDL10 to 37 are transmitted. The transmit multiframe begin interrupt (XMB) requests that these registers should be serviced. If requests for new information are ignored, the current contents is repeated. Clear Channel Register (Read/Write) Value after reset: 00H, 00H, 00H 7 0 CCB1 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 (2F) CCB2 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 (30) CCB3 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 (31) CH(24:1) Data Sheet Channel Selection Bits 0= Normal operation. Bit robbing information and zero code suppression (ZCS, B7 stuffing) can change contents of the selected speech/data channel if assigned modes are enabled by bits FMR5.EIBR and FMR0.XC(1:0). 1= Clear channel mode. Contents of selected speech/data channel are not overwritten by internal or external bit robbing and ZCS information. Transmission of channel assigned signaling and control of pulse-density is applied by the user. 363 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Idle Channel Register (Read/Write) Value after reset: 00H, 00H, 00H, 00H 7 0 ICB1 IC1 IC2 IC3 IC4 IC5 IC6 IC7 IC8 (32) ICB2 IC9 IC10 IC11 IC12 IC13 IC14 IC15 IC16 (33) ICB3 IC17 IC18 IC19 IC20 IC21 IC22 IC23 IC24 (34) IC(24:1) Idle Channel Selection Bits These bits define the channels (time slots) of the outgoing PCM frame to be altered. 0= Normal operation. 1= Idle channel mode. The contents of the selected channel is overwritten by the idle channel code defined by register IDLE. Line Interface Mode 0 (Read/Write) Value after reset: 00H 7 LIM0 XFB XFB 0 XDOS EQON RLM LL MAS (36) Transmit Full Bauded Mode Only applicable for dual-rail mode (bit LIM1.DRS = 1). 0= Output signals XDOP/XDON are half bauded (normal operation). 1= Output signals XDOP/XDON are full bauded. Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to be cleared. Data Sheet 364 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XDOS Transmit Data Out Sense 0= Output signals XDOP/XDON are active low. Output XOID is active high (normal operation). 1= Output signals XDOP/XDON are active high. Output XOID is active low. Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to be cleared. The transmit frame marker XFM is independent of this bit. EQON RLM LL MAS Data Sheet Receive Equalizer On 0= -10 dB receiver: short-haul mode 1= -36 dB receiver: long-haul mode Receive Line Monitoring 0= Normal receiver mode 1= Receiver mode for receive line monitoring; the receiver sensitivity is increased to detect resistively attenuated signals of -20 dB (short-haul mode only) Local Loop 0= Normal operation 1= Local loop active. The local loop-back mode disconnects the receive lines RL1/RL2 or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data provided by system interface is routed through the analog receiver back to the system interface. The unipolar bit stream is transmitted undisturbedly on the line. Receiver and transmitter coding must be identical. Operates in analog and digital line interface mode. In analog line interface mode data is transferred through the complete analog receiver. Master Mode 0= Slave mode 1= Master mode on. Setting this bit the DCO-R circuitry is frequency synchronized to the clock (1.544, 2.048 MHz or 8 kHz, see IPC.SSYF, LIM1.DCOC) supplied by SYNC. If this pin is connected to VSS or VDD (or left open and pulled up to VDD internally) the DCO-R circuitry is centered and no receive jitter attenuation is performed (only if 1.544 or 2.048 MHz clock is selected by resetting bit IPC.SSYF). The generated clocks are stable. 365 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Line Interface Mode 1 (Read/Write) Value after reset: 00H 7 LIM1 CLOS RIL(2:0) CLOS 0 RIL2 RIL1 RIL0 DCOC JATT RL DRS (37) Clear data in case of LOS 0= Normal receiver mode, receive data stream is transferred normally in long-haul mode 1= In long-haul mode received data is cleared (driven low), as soon as LOS is detected Receive Input Threshold Only valid if analog line interface is selected (LIM1.DRS = 0). “No signal” is declared if the voltage between pins RL1 and RL2 drops below the limits programmed by bits RIL(2:0) and the received data stream has no transition for a period defined in the PCD register. The threshold where “no signal” is declared is programmable by the RIL(2:0) bits depending on bit LIM0.EQON. Note: LIM1.RIL(2:0) must be programmed before LIM0.EQON = 1 is set. See the DC characteristics for detail. DCOC DCO-R Control 0= 1.544 MHz reference clock for the DCO-R circuitry provided on pin SYNC. 1= 2.048 MHz reference clock for the DCO-R circuitry provided on pin SYNC. Note: If IPC.SSYF = 1, external reference clock frequency is 8.0 kHz independent of DCOC. Data Sheet 366 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers JATT, RL Remote Loop Transmit Jitter Attenuator 00 = Normal operation. The remote loop transmit jitter attenuator is disabled. Transmit data bypasses the remote loop jitter attenuator buffer. 01 = Remote Loop active without transmit jitter attenuator enabled. Transmit data bypasses the remote loop jitter attenuator buffer. 10 = not assigned 11 = Remote Loop and remote loop jitter attenuator active. Received data from pins RL1/2 or RDIP/N or ROID is sent "jitter-free" on ports XL1/2 or XDOP/N or XOID. The de-jittered clock is generated by the DCO-X circuitry. Note: JATT is only used to define the jitter attenuation during remote loop operation. Jitter attenuation during normal operation is not affected. DRS Dual-Rail Select 0= The ternary interface is selected. Multifunction ports RL1/2 and XL1/2 become analog in/outputs. 1= The digital dual-rail interface is selected. Received data is latched on multifunction ports RDIP/RDIN while transmit data is output on pins XDOP/XDON. Pulse Count Detection Register (Read/Write) Value after reset: 00H PCD PCD(7:0) 7 0 PCD7 PCD0 (38) Pulse Count Detection A LOS alarm (red alarm) is detected if the incoming data stream has no transitions for a programmable number T consecutive pulse positions. The number T is programmable by the PCD register and can be calculated as follows: T = 16 × (N+1); with 0 ≤ N ≤ 255. The maximum time is: 256 × 16 × 648 ns = 2.65 ms. Every detected pulse resets the internal pulse counter. The counter is clocked with the receive clock RCLK. Data Sheet 367 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Pulse Count Recovery (Read/Write) Value after reset: 00H PCR PCR(7:0) 7 0 PCR7 PCR0 (39) Pulse Count Recovery A LOS alarm (red alarm) is cleared if a pulse-density is detected in the received bit stream. The number of pulses M which must occur in the predefined PCD time interval is programmable by the PCR register and can be calculated as follows: M = N+1; with 0 ≤ N ≤ 255. The time interval starts with the first detected pulse transition. With every received pulse a counter is incremented and the actual counter is compared to the contents of PCR register. If the pulse number reaches or exceeds the PCR value the LOS alarm is reset otherwise the alarm stays active. In this case the next detected pulse transition starts a new time interval. An additional loss-of-signal recovery condition is selected by register LIM2.LOS1. Data Sheet 368 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Line Interface Mode 2 (Read/Write) Value after reset: 20H 7 LIM2 LBO(2:1) LBO2 0 LBO1 SLT1 SLT0 SCF ELT LOS1 (3A) Line Build-Out In long-haul applications LIM0.EQON = 1 a transmit filter can be optionally placed on the transmit path to attenuate the data on pins XL1/2. Selecting the transmitter attenuation is possible in steps of 7.5 dB at 772kHz which is according to FCC68 and ANSI T1.403. To meet the line build-out defined by ANSI T1.403 registers XPM(2:0) should be programmed as follows: SLT(1:0) 00 = 0 dB 01 = 7.5 dB →XPM(2:0) = 20H, 02H, 51H 10 = -15 dB →XPM(2:0) = 20H, 01H, 51H 11 = -22.5 dB →XPM(2:0) = 20H, 01H, 50H Receive Slicer Threshold 00 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 55% of the peak amplitude. 01 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 67% of the peak amplitude (may be used in some T1/J1 applications). 10 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 50% of the peak amplitude (default, recommended in T1/J1 mode). 11 = The receive slicer generates a mark (digital one) if the voltage at RL1/2 exceeds 45% of the peak amplitude. SCF Select Corner Frequency of DCO-R Setting this bit reduces the corner frequency of the DCO-R circuit by the factor of ten to 0.6 Hz. Note: Reducing the corner frequency of the DCO-R circuitry increases the synchronization time before the frequencies are synchronized. Data Sheet 369 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers ELT Enable Loop-Timed LOS1 0= Normal operation 1= Transmit clock is generated from the clock supplied by MCLK which is synchronized to the extracted receive route clock. In this configuration the transmit elastic buffer has to be enabled. Refer to register FMR5.XTM. For correct operation of loop timed the remote loop (bit LIM1.RL = 0) must be inactive and bit CMR1.DXSS must be cleared. Loss-of-Signal Recovery condition 0= The LOS alarm is cleared if the predefined pulse-density (register PCR) is detected during the time interval which is defined by register PCD. 1= Additionally to the recovery condition described above a LOS alarm is only cleared if the pulse-density is fulfilled and no more than 15 contiguous zeros are detected during the recovery interval (according to GR-499-CORE). Loop Code Register 1 (Read/Write) Value after reset: 00H 7 LCR1 EPRM XPRBS EPRM 0 XPRBS LDC1 LDC0 LAC1 LAC0 FLLB LLBP (3B) Enable Pseudo-Random Binary Sequence Monitor 0= Pseudo-random binary sequence (PRBS) monitor is disabled. 1= PRBS is enabled. Setting this bit enables incrementing the bit error counter BEC with each detected PRBS bit error. With any change of state of the PRBS internal synchronization status an interrupt ISR3.LLBSC is generated. The current status of the PRBS synchronizer is indicated by bit FRS1.LLBAD. Transmit Pseudo-Random Binary Sequence A one in this bit position enables transmission of a pseudo-random binary sequence to the remote end. Depending on bit LLBP the PRBS is generated according to 215 -1 or 220-1 (ITU-T O. 151). Data Sheet 370 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers LDC(1:0) Length Deactivate (Down) Code These bits defines the length of the LLB deactivate code which is programmable in register LCR2. 00 = Length: 5 bit 01 = Length: 6 bit, 2 bit, 3 bit 10 = Length: 7 bit 11 = Length: 8 bit, 2 bit, 4bit LAC(1:0) Length Activate (Up) Code These bits defines the length of the LLB activate code which is programmable in register LCR3. 00 = Length: 5 bit 01 = Length: 6 bit, 2 bit, 3 bit 10 = Length: 7 bit 11 = Length: 8 bit, 2 bit, 4bit FLLB Framed Line Loop-Back/Invert PRBS Depending on bit LCR1.XPRBS this bit enables different functions: LCR1.XPRBS = 0: 0= The line loop-back code is transmitted including framing bits. LLB code overwrites the FS/DL-bits. 1= The line loop-back code is transmitted unframed. LLB code does not overwrite the FS/DL-bits. Invert PRBS LCR1.XPRBS = 1: LLBP 0= The generated PRBS is transmitted not inverted. 1= The PRBS is transmitted inverted. Line Loop-Back Pattern LCR1.XPRBS = 0 0= Fixed line loop-back code according to ANSI T1. 403. 1= Enable user-programmable line loop-back code by register LCR2/3. LCR1.XPRBS = 1 or LCR1.EPRM = 1 Data Sheet 0= 215 -1 1= 220 -1 371 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Loop Code Register 2 (Read/Write) Value after reset: 00H LCR2 7 0 LDC7 LDC0 LDC(7:0) (3C) Line Loop-Back Deactivate Code If enabled by bit FMR5.XLD = 1 the LLB deactivate code automatically repeats until the LLB generator is stopped. Transmit data is overwritten by the LLB code. LDC0 is transmitted last. For correct operations bit LCR1.XPRBS has to cleared. If LCR2 is changed while the previous deactivate code has been detected and is still received, bit FRS1.LLBDD will stay active until the incoming signal changes or a receiver reset is initiated (CMDR.RRES = 1). Loop Code Register 3 (Read/Write) Value after reset: 00H LCR3 LAC(7:0) 7 0 LAC7 LAC0 (3D) Line Loop-Back Activate Code If enabled by bit FMR5.XLU = 1 the LLB activate code automatically repeats until the LLB generator is stopped. Transmit data is overwritten by the LLB code. LAC0 is transmitted last. For correct operations bit LCR1.XPRBS has to cleared. If LCR3 is changed while the previous activate code has been detected and is still received, bit FRS1.LLBAD will stay active until the incoming signal changes or a receiver reset is initiated (CMDR.RRES = 1). Data Sheet 372 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers System Interface Control 1 (Read/Write) Value after reset: 00H 7 SIC1 SSC(1:0) SSC1 0 SSD1 RBS1 RBS0 SSC0 BIM XBS1 XBS0 (3E) Select System Clock SIC1.SSC(1:0) and SIC2.SSC2 define the clocking rate on the system highway. SIC2.SSC2 = 0: 00 = 2.048 MHz 01 = 4.096 MHz 10 = 8.192 MHz 11 = 16.384 MHz SIC2.SSC2 = 1: 00 = 1.544 MHz 01 = 3.088 MHz 10 = 6.176 MHz 11 = 12.352 MHz SSD1 Select System Data Rate 1 SIC1.SSD1, FMR1.SSD0 and SIC2.SSC2 define the data rate on the system highway. Programming SSD1/SSD0 and corresponding data rate is shown below. SIC2.SSC2 = 0: 00 = 2.048 Mbit/s 01 = 4.096 Mbit/s 10 = 8.192 Mbit/s 11 = 16.384 Mbit/s SIC2 .SSC2 = 1: 00 =1.544 Mbit/s 01 = 3.088 Mbit/s 10 = 6.176 Mbit/s 11 = 12.352 Mbit/s Data Sheet 373 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RBS(1:0) Receive Buffer Size 00 = Buffer size: 2 frames 01 = Buffer size: 1 frame 10 = Buffer size: 96 bits 11 = Bypass of receive elastic store BIM Bit Interleaved Mode Only applicable if bit SIC2.SSC2 is cleared. If SIC2.SSC2 is set high, the bit interleaved mode is automatically performed. XBS(1:0) 0= Byte interleaved mode 1= Bit interleaved mode Transmit Buffer Size 00 = Bypass of transmit elastic store 01 = Buffer size: 1 frame 10 = Buffer size: 2 frames 11 = Buffer size: 96 bits System Interface Control 2 (Read/Write) Value after reset: 00H 7 SIC2 FFS FFS 0 SSF CRB SSC2 SICS2 SICS1 SICS0 (3F) Force Freeze Signaling Setting this bit disables updating of the receive signaling buffer and current signaling information is frozen. After resetting this bit and receiving a complete superframe updating of the signaling buffer is started again. The freeze signaling status can also be generated automatically by detection of a loss-of-signal alarm or a loss of frame alignment or a receive slip (only if external register access through RSIG is enabled). This automatic freeze signaling function is logically ored with this bit. The current internal freeze signaling status is output on pin RP(A to D) with selected pin function FREEZE (PC(4:1).RPC(2:0) = 110). Additionally this status is also available in register SIS.SFS. Data Sheet 374 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers SSF Serial Signaling Format Only applicable if pin function RSIG/XSIG and SIC3.TTRF = 0 is selected. CRB 0= Bits 1 to 4 in all time slots except time slot 0 are cleared. 1= Bits 1 to 4 in all time slots except time slot 0 are set high. Center Receive Elastic Buffer Only applicable if the time slot assigner is disabled (PC(4:1).RPC(2:0) = 001B), no external or internal synchronous pulse receive is generated. A transition from low to high forces a receive slip and the read pointer of the receive elastic buffer is centered. The delay through the buffer is set to one half of the current buffer size. It should be hold high for at least two 1.544 MHz periods before it is cleared. SSC2 Select System Clock This bit together with SIC1.SSC1/0 enables the system interface to run with a clock of 1.544, 3.088, 6.176 or 12.352 MHz (SSC2 = 1) or 2.048, 4.096, 8.192 or 16.384 MHz (SSC2 = 0). See also register SIC1.SSC1/0 on page 373. SICS(2:0) System Interface Channel Select Only applicable if the system clock rate is greater than 1.544⁄2.048MHz. Received data is transmitted on pin RDO/RSIG or received on XDI⁄XSIG with the selected system data rate. If the data rate is greater than 1.544/2.048 Mbit/s the data is output or sampled in half, a quarter or one eighth of the time slot. Data is not repeated. The time while data is active during a 8 × 488/648 ns time slot is called a channel phase. RDO/RSIG are cleared (driven to low level) while XDI⁄XSIG are ignored for the remaining time of the 8 × 488/648 ns or for the remaining channel phases. The channel phases are selectable with these bits. Data Sheet 000 = Data active in channel phase 1, valid if system data rate is 16/8/4 or 12/6/3 Mbit/s 001 = Data active in channel phase 2, valid if data rate is 16/8/4 or 12/6/3 Mbit/s 010 = Data active in channel phase 3, valid if data rate is 16/8 or 12/6 Mbit/s 011 = Data active in channel phase 4, valid if data rate is 16/8 or 12/6 Mbit/s 375 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 100 = Data active in channel phase 5, valid if data rate is 16 or 12 Mbit/s 101 = Data active in channel phase 6, valid if data rate is 16 or 12 Mbit/s 110 = Data active in channel phase 7, valid if data rate is 16 or 12 Mbit/s 111 = Data active in channel phase 8, valid if data rate is 16 or 12 Mbit/s System Interface Control 3(Read/Write) Value after reset: 00H 7 SIC3 CMI 0 CMI RESX RESR TTRF DAF (40) Select CMI Precoding Only valid if CMI code (FMR0.XC(1:0) = 01) is selected. This bit defines the CMI precoding and influences transmit and receive data. 0= CMI with B8ZS precoding 1= CMI without B8ZS precoding Note:Before local loop is closed, B8ZS precoding has to be switched off. RESX Rising Edge Synchronous Pulse Transmit Depending on this bit all transmit system interface data and marker are clocked or sampled with the selected active edge. CMR2.IXSC = 0: 0 latched with the first falling edge of the selected PCM highway clock. 1 latched with the first rising edge of the selected PCM highway clock. CMR2.IXSC = 1: value of RESX bit has no impact on the selected edge of the PCM highway clock but value of RESR bit is used as RESX. Example: If RESR = 0, the rising edge of PCM highway clock is the selected one for sampling data on XDI and vice versa. Data Sheet 376 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RESR Rising Edge Synchronous Pulse Receive Depending on this bit all receive system interface data and marker are clocked with the selected active edge. 0= Latched with the first falling edge of the selected PCM highway clock. 1= Latched with the first rising edge of the selected PCM highway clock. Note: If bit CMR2.IRSP is set, the behavior of signal RFM (if used) is inverse (1 = falling edge, 0 = rising edge) TTRF TTR Register Function (Fractional T1/J1 Access) Setting this bit the function of the TTR(4:1) registers are changed. A one in each TTR register forces the XSIGM marker high for the corresponding time slot and controls sampling of the time slots provided on pin XSIG. XSIG is selected by PC(4:1).XPC(3:0). DAF Data Sheet Disable Automatic Freeze 0= Signaling is automatically frozen if one of the following alarms occurred: Loss-Of-signal (FRS0.LOS), Loss-of-FrameAlignment (FRS0.LFA), or receive slips (ISR3.RSP/N). 1= Automatic freezing of signaling data is disabled. Updating of the signaling buffer is also done if one of the above described alarm conditions is active. However, updating of the signaling buffer is stopped if SIC2.FFS is set. Significant only if the serial signaling access is enabled. 377 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Clock Mode Register 1 (Read/Write) Value after reset: 00H 7 0 CMR1 RS(1:0) RS1 RS0 DCS STF DXJA DXSS (44) Select RCLK Source These bits select the source of RCLK. 00 = Clock recovered from the line through the DPLL drives RCLK 01 = Clock recovered from the line through the DPLL drives RCLK and in case of an active LOS alarm RCLK pin is set high. 10 = Clock recovered from the line is de-jittered by DCO-R to drive a 2.048 MHz (SIC2.SSC2 = 0) or 1.544 MHz (SIC2.SSC2 = 1) clock on RCLK. 11 = Clock recovered from the line is de-jittered by DCO-R to drive a 8.192 MHz (SIC2.SSC2 = 0) or 6.176 MHz (SIC2.SSC2 = 1) clock on RCLK. DCS Disable Clock-Switching In Slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the recovered route clock. In case of LOS the DCO-R switches automatically to the clock sourced by port SYNC. Setting this bit automatic switching from RCLK to SYNC is disabled. STF Select TCLK Frequency Only applicable if the pin function TCLK port XP(A to D) is selected by PC(4:1).XPC(3:0) = 0011B. Data on XL1/2, XDOP/N, XOID are clocked with TCLK. DXJA 0= 1.544 MHz 1= 6.176 MHz Disable Internal Transmit Jitter Attenuation Setting this bit disables the transmit jitter attenuation. Reading the data out of the transmit elastic buffer and transmitting on XL1/2 (XDOP/N/XOID) is done with the clock provided on pin TCLK. In transmit elastic buffer bypass mode the transmit clock is taken from SCLKX, independent of this bit. Data Sheet 378 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers DXSS DCO-X Synchronization Clock Source 0= The DCO-X circuitry synchronizes to the internal reference clock which is sourced by SCLKX/R or RCLK. Since there are many reference clock opportunities the following internal prioritizing in descending order from left to right is realized: LIM1.RL > CMR1.DXSS > LIM2.ELT > current working clock of transmit system interface. If one of these bits is set the corresponding reference clock is taken. 1= DCO-X synchronizes to an external reference clock provided on pin XP(A to D) pin function TCLK, if no remote loop is active. TCLK is selected by PC(4:1).XPC(3:0) = 0011B Clock Mode Register 2 (Read/Write) Value after reset: 00H 7 0 CMR2 DCOXC DCF Data Sheet DCOXC DCF IRSP IRSC IXSP IXSC (45) DCO-X Center-Frequency Enable 0= The center function of the DCO-X circuitry is disabled. 1= The center function of the DCO-X circuitry is enabled. DCO-X centers to 1.544 MHz related to the master clock reference (MCLK), if reference clock (e.g. SCLKX) is missing. DCO-R Center- Frequency Disabled 0= The DCO-R circuitry is frequency centered - in master mode if no 1.544 or 2.048 MHz reference clock on pin SYNC is provided or - in slave mode if a loss-of-signal occurs in combination with no 1.544 or 2.048 MHz clock on pin SYNC or - a gapped clock is provided on pin RCLKI and this clock is inactive or stopped. 1= The center function of the DCO-R circuitry is disabled. The generated clock (DCO-R) is frequency frozen in that moment when no clock is available on pin SYNC or pin RCLKI. The DCO-R circuitry starts synchronization as soon as a clock on pins SYNC or RCLKI appears. 379 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers IRSP Internal Receive System Frame Sync Pulse 0= The frame sync pulse for the receive system interface is sourced by SYPR (if SYPR is applied). If SYPR is not applied, the frame sync pulse is derived from RDO output signal internally free running). The use of IRSP = 0 is recommended. 1= The frame sync pulse for the receive system interface is internally sourced by the DCO-R circuitry. This internally generated frame sync signal can be output (active low) on multifunction ports RP(A to D) (RPC(2:0) = 001B). Note: This is the only exception where the use of RFM and SYPR is allowed at the same time. Because only one set of offset registers (RC1/0) is available, programming is done by using the SYPR calculation formula in the same way as for the external SYPR pulse. Bit IRSC must be set for correct operation. IRSC IXSP IXSC Data Sheet Internal Receive System Clock 0= The working clock for the receive system interface is sourced by SCLKR of or in receive elastic buffer bypass mode from the corresponding extracted receive clock RCLK. 1= The working clock for the receive system interface is sourced internally by DCO-R or in bypass mode by the extracted receive clock. SCLKR is ignored. Internal Transmit System Frame Sync Pulse 0= The frame sync pulse for the transmit system interface is sourced by SYPX. 1= The frame sync pulse for the transmit system interface is internally sourced by the DCO-R circuitry. Additionally, the external XMFS signal defines the transmit multiframe begin. XMFS is enabled or disabled by the multifunction port configuration. For correct operation bits CMR2.IXSC/IRSC must be set. SYPX is ignored. Internal Transmit System Clock 0= The working clock for the transmit system interface is sourced by SCLKX. 1= The working clock for the transmit system interface is sourced internally by the working clock of the receive system interface. SCLKX is ignored. 380 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Global Configuration Register (Read/Write) Value after reset: 00H 7 GCR VIS SCI SES ECMC PD VIS 0 SCI SES ECMC PD (46) Masked Interrupts Visible 0= Masked interrupt status bits are not visible in registers ISR(5:0). 1= Masked interrupt status bits are visible in ISR(5:0), but they are not visible in registers GIS. Status Change Interrupt 0= Interrupts are generated either on activation or deactivation of the internal interrupt source. 1= The following interrupts are activated both on activation and deactivation of the internal interrupt source: ISR2.LOS, ISR2.AIS and ISR0.PDEN Select External Second Timer 0= Internal second timer selected 1= External second timer selected Error Counter Mode COFA 0= Not defined; reserved for future applications. 1= A Change of Frame or Multiframe Alignment COFA is detected since the last resynchronization. The events are accumulated in the COFA event counter COEC.(1:0). Multiframe periods received in the asynchronous state are accumulated in the COFA event counter COEC.(7:2). An overflow of each counter is disabled. Power Down Switches between power-up and power-down mode. Data Sheet 0= Power up 1= Power down All outputs are driven inactive, except the multifunction ports, which are weakly driven high by the internal pullup devices. 381 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Errored Second Mask (Read/Write) Value after reset: FFH 7 ESM LFA ESM 0 FER CER AIS LOS CVE SLIP (47) Errored Second Mask This register functions as an additional mask register for the interrupt status bit Errored Second (ISR3.ES). A "1" in a bit position of ESM deactivates the related second interrupt. Disable Error Counter (Write) Value after reset: 00H 7 DEC DRBD DRBD 0 DCOEC DBEC DCEC DEBC DCVC DFEC (60) Disable Receive Buffer Delay This bit has to be set before reading the register RBD. It is automatically reset if RBD has been read. DCOEC Disable COFA Event Counter DBEC Disable PRBS Bit Error Counter Only valid if LCR1.EPRM = 1 and FMR1.ECM are reset. DCEC Disable CRC Error Counter DEBC Disable Errored Block Counter DCVC Disable Code Violation Counter DFEC Disable Framing Error Counter These bits are only valid if FMR1.ECM is cleared. They have to be set before reading the error counters. They are reset automatically if the corresponding error counter high byte has been read. With the rising edge of these bits the error counters are latched and then cleared. Note: Error counters and receive buffer delay can be read 1 µs after setting the according bit in bit DEC. Data Sheet 382 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Transmit Signaling Register (Write) Value after reset: not defined Table 65 Transmit Signaling Registers (T1/J1) 7 0 XS1 A1 B1 C1/A2 D1/B2 A2/A3 B2/B3 C2/A4 D2/B4 (70) XS2 A3/A5 B3/B5 C3/A6 D3/B6 A4/A7 B4/B7 C4/A8 D4/B8 (71) XS3 A5/A9 B5/B9 C5/A10 D5/B10 A6/A11 B6/B11 C6/A12 D6/B12 (72) XS4 A7/A13 B7/B13 C7/A14 D7/B14 A8/A15 B8/B15 C8/A16 D8/B16 (73) XS5 A9/A17 B9/B17 C9/A18 D9/B18 A10/A19 B10/B19 C10/A20 D10/B20 (74) XS6 A11/A21 B11/B21 C11/A22 D11/B22 A12/A23 B12/B23 C12/A24 D12/B24 (75) XS7 A13/A1 B13/B1 C13/A2 D13/B2 A14/A3 B14/B3 C14/A4 D14/B4 (76) XS8 A15/A5 B15/B5 C15/A6 D15/B6 A16/A7 B16/B7 C16/A8 D16/B8 (77) XS9 A17/A9 B17/B9 C17/A10 D17/B10 A18/A11 B18/B11 C18/A12 D18/B12 (78) XS10 A19/A13 B19/B13 C19/A14 D19/B14 A20/A15 B20/B15 C20/A16 D20/B16 (79) XS11 A21/A17 B21/B17 C21/A18 D21/B18 A22/A19 B22/B19 C22/A20 D22/B20 (7A) XS12 A23/A21 B23/B21 C23/A22 D23/B22 A24/A23 B24/B23 C24/A24 D24/B24 (7B) Transmit Signaling Register 1 to 12 The transmit signaling register access is enabled by setting bit FMR5.EIBR = 1. Each register contains the bit robbing information for 8 DS0 channels. With the transmit CAS empty interrupt ISR1.CASE the contents of these registers is copied into a shadow register. The contents is subsequently sent out in the corresponding bit positions of the next outgoing multiframe. XS1.7 is sent out first in channel 1 frame 1 and XS12.0 is sent out last. The transmit CAS empty interrupt ISR1.CASE requests that these registers should be serviced within the next 3 ms. If requests for new information are ignored, current contents is repeated. Note: If access to XS(12:1) registers is done without control of the interrupt ISR1.CASE and the write access to these registers is done exact in that moment when this interrupt is generated, data is lost. A software reset (CMDR.XRES) resets these registers. Data Sheet 383 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Port Configuration 1 to 4 (Read/Write) Value after reset: 00H 7 0 PC1 RPC12 RPC11 RPC10 XPC13 XPC12 XPC11 XPC10 (80) PC2 RPC22 RPC21 RPC20 XPC23 XPC22 XPC21 XPC20 (81) PC3 RPC32 RPC31 RPC30 XPC33 XPC32 XPC31 XPC30 (82) PC4 RPC42 RPC41 RPC40 XPC43 XPC42 XPC41 XPC40 (83) RPC(2:0) Receive multifunction port configuration The multifunction ports RP(A to D) are bidirectional. After Reset these ports are configured as inputs. With the selection of the pin function the In/Output configuration is also achieved. The input function SYPR may only be selected once, it must not be selected twice or more. Register PC1 configures port RPA, while PC2 → port RPB, PC3 → port RPC and PC4 → port RPD. 000 = SYPR: Synchronous Pulse Receive (Input) Together with register RC(1:0) SYPR defines the frame begin on the receive system interface. Because of the offset programming the SYPR and the RFM pin function cannot be selected in parallel. 001 = RFM: Receive Frame Marker (Output) CMR2.IRSP = 0: The receive frame marker is active high for one 1.544 MHz period during any bit position of the current frame. Programming of the bit position is done by using registers RC(1:0). The internal time slot assigner is disabled. The RFM offset calculation formula has to be used. CMR2.IRSP = 1: Internally generated frame synchronization pulse sourced by the DCO-R circuitry. The pulse is active low for one 1.544 MHz period. 010 = RMFB: Receive Multiframe Begin (Output) Marks the beginning of every received multiframe or optionally the begin of every CAS multiframe begin (active high). Data Sheet 384 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 011 = RSIGM: Receive Signaling Marker (Output) Marks the time slots which are defined by register RTR(4:1) of every frame on port RDO. 100 = RSIG: Receive Signaling Data (Output) The received CAS multiframe is transmitted on this pin. Time slot on RSIG correlates directly to the time slot assignment on RDO. 101 = DLR: Data Link Bit Receive (Output) Marks the Sa-bits within the data stream on RDO. 110 = FREEZE: Freeze Signaling (Output) The freeze signaling status is active high by detecting a Lossof-signal alarm, or a Loss of CAS Frame Alignment or a receive slip (positive or negative). It stays high for at least one complete multiframe after the alarm disappears. Setting SIC2.FFS enforces a high on pin FREEZE. 111 = RFSP: Receive Frame Synchronous Pulse (Output) Marks the frame begin in the receivers synchronous state. This marker is active low for 488 ns with a frequency of 8 kHz. XPC(3:0) Transmit multifunction Port Configuration The multifunction ports XP(A to D) are bidirectional. After Reset these ports are configured as inputs. With the selection of the pin function the In/Output configuration is also achieved. Each of the four different input functions (SYPX, XMFS, XSIG, TCLK) may only be selected once. No input function must be selected twice or more. SYPX and XMFS should not be selected in parallel. Register PC1 configures port XPA, while PC2 → port XPB, PC3 → port XPC and PC4 → port XPD. 0000 = SYPX: Synchronous Pulse Transmit (Input) Together with register XC(1:0) SYPX defines the frame begin on the transmit system interface ports XDI and XSIG. 0001 = XMFS: Transmit Multiframe Synchronization (Input) Together with register XC(1:0) XMFS defines the frame and multiframe begin on the transmit system interface ports XDI and XSIG. Depending on PC5.CXMFS the signal on XMFS is active high or low. 0010 = XSIG: Transmit Signaling Data (Input) Input for transmit signaling data received from the signaling highway. Optionally sampling of XSIG data is controlled by the active high XSIGM marker. Data Sheet 385 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 0011 = TCLK: Transmit Clock (Input) A 1.544/6.176MHz clock has to be sourced by the system if the internal generated transmit clock (DCO-X) is not used. Optionally this input is used as a synchronization clock for the DCO-X circuitry with a frequency of 1.544 or 6.176 MHz. 0100 = XMFB: Transmit Multiframe Begin (Output) Marks the beginning of every transmit multiframe. 0101 = XSIGM: Transmit Signaling Marker (Output) Marks the time slots which are defined by register TTR(4:1) of every frame on port XDI. 0110 = DLX: Data Link Bit Transmit (Output) Marks the Sa-bits within the data stream on XDI. 0111 = XCLK: Transmit Line Clock (Output) Frequency: 1.544MHz 1000 = XLT: Transmit Line Tristate (Input) With a high level on this port the transmit lines XL1/2 or XDOP/N are set directly into tristate. This pin function is logically ored with register XPM2.XLT. Port Configuration 5 (Read/Write) Value after reset: 00H 7 0 PC5 CCLK2 CCLK1 CXMFS Data Sheet CCLK2 CCLK1 CXMFS 0 CSRP CRP (84) Configure CLK2 Port 0= CLK2 is input 1= CLK2 is output (only if DCO-X is active) Configure CLK1 Port 0= CLK1 is input 1= CLK1 is output (only if DCO-R is active) Configure XMFS Port 0= Port XMFS is active low. 1= Port XMFS is active high. 386 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers P C5(2) reserved. Must be cleared CSRP Configure SCLKR Port CRP 0= SCLKR: Input 1= SCLKR: Output Configure RCLK Port 0= RCLK: Input 1= RCLK: Output Global Port Configuration 1 (Read/Write) Value after reset: 00H 7 0 GPC1 CSFP1 CSFP0 (85) CSFP(1:0) Configure SEC/FSC Port The FSC pulse is generated if the DCO-R circuitry of the selected channel is active (CMR2.IRSC = 1 or CMR1.RS(1:0) = 10B or 11B). 00 = SEC: Input, active high 01 = SEC: Output, active high 10 = FSC: Output, active high 11 = FSC: Output, active low Data Sheet 387 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Port Configuration 6 (Read/Write) Value after reset: 00H 7 0 PC6 SXCL(1:0) SXCL1 SXCL0 SCL2 SCL1 SCL0 (86) Select Transmit Clock Frequency on Port CLK2 Port CLK2 is the de-jittered DCO-X clock at a frequency of 00 = 1.544 MHz 01 = 3.088MHz 10 = 6.176 MHz 11 = 12.352 MHz Note: If DCO-X is not used, no clock is output on pin CLK2 (SIC1.XBS(1:0)=00 and CMR1.DXJA=1; buffer bypass and no jitter attenuation) SCL(2:0) Select System Clock Frequency on Port CLK1 Port CLK1 is the de-jittered DCO-R clock at a frequency of SIC2.SSC2=0: 000 = 8 kHz 001 = 2.048 MHz 010 = 4.096 MHz 011 = 8.192 MHz 100 = 16.384 MHz 101 to 111 = Not defined SIC2.SSC2=1: 000 = 8 kHz 001 = 1.544 MHz 010 = 3.088 MHz 011 = 6.176 MHz 100 = 12.352 MHz 101 to 111 = Not defined Note:If DCO-R is not active, no clock is output on pin CLK1 (SIC1.RBS(1:0)=11 and CMR1.RS1=0). Data Sheet 388 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Command Register 2 (Write) Value after reset: 00H CMDR2 RSUC RSUC XPPR (87) Reset Signaling Unit Counter - HDLC Channel 1 After setting this bit the SS7 signaling unit counter and error counter are reset.The bit is cleared automatically after execution. Note: The maximum time between writing to the CMDR2 register and the execution of the command takes 2.5 periods of the current system data rate. Therefore, if the CPU operates with a very high clock rate in comparison with the FALC56's clock, it is recommended that bit SIS.CEC should be checked before writing to the CMDR register to avoid any loss of commands. XPPR Transmit Periodical Performance Report (PPR) After setting this bit the last PPR is sent once. The bit is cleared automatically after completion. Applies to HDLC channel 1 only. Command Register 3 (Write) Value after reset: 00H 7 CMDR3 RMC2 RMC2 0 XREP2 XHF2 XTF2 XME2 SRES2 (88) Receive Message Complete - HDLC Channel 2 Confirmation from CPU to FALC® that the current frame or data block has been fetched following an RPF2 or RME2 interrupt, thus the occupied space in the RFIFO2 can be released. XREP2 Transmission Repeat - HDLC Channel 2 If XREP2 is set together with XTF2 (write 24H to CMDR3), the FALC® repeatedly transmits the contents of the XFIFO2 (1 to 32 bytes) without HDLC framing fully transparently, i.e. without flag, CRC. The cyclic transmission is stopped with an SRES2 command or by resetting XREP2. Data Sheet 389 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XHF2 Transmit HDLC Frame - HDLC Channel 2 After having written up to 32 bytes to the XFIFO2, this command initiates the transmission of a HDLC frame. XTF2 Transmit Transparent Frame - HDLC Channel 2 Initiates the transmission of a transparent frame without HDLC framing. XME2 Transmit Message End - HDLC Channel 2 Indicates that the data block written last to the XFIFO2 completes the current frame. The FALC® can terminate the transmission operation properly by appending the CRC and the closing flag sequence to the data. SRES2 Signaling Transmitter Reset - HDLC Channel 2 The transmitter of the signaling controller is reset. XFIFO2 is cleared of any data and an abort sequence (seven 1s) followed by interframe time fill is transmitted. In response to SRES2 an XPR2 interrupt is generated. This command can be used by the CPU to abort a frame currently in transmission. Command Register 4 (Write) Value after reset: 00H 7 CMDR4 RMC3 RMC3 0 XREP3 XHF3 XTF3 XME3 SRES3 (89) Receive Message Complete - HDLC Channel 3 Confirmation from CPU to FALC® that the current frame or data block has been fetched following an RPF3 or RME3 interrupt, thus the occupied space in the RFIFO3 can be released. XREP3 Transmission Repeat - HDLC Channel 3 If XREP3 is set together with XTF3 (write 24H to CMDR4), the FALC® repeatedly transmits the contents of the XFIFO3 (1 to 32 bytes) without HDLC framing fully transparently, i.e. without flag, CRC. The cyclic transmission is stopped with an SRES3 command or by resetting XREP3. Data Sheet 390 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XHF3 Transmit HDLC Frame - HDLC Channel 3 After having written up to 32 bytes to the XFIFO3, this command initiates the transmission of a HDLC frame. XTF3 Transmit Transparent Frame - HDLC Channel 3 Initiates the transmission of a transparent frame without HDLC framing. XME3 Transmit Message End - HDLC Channel 3 Indicates that the data block written last to the XFIFO3 completes the current frame. The FALC® can terminate the transmission operation properly by appending the CRC and the closing flag sequence to the data. SRES3 Signaling Transmitter Reset - HDLC Channel 3 The transmitter of the signaling controller is reset. XFIFO3 is cleared of any data and an abort sequence (seven 1s) followed by interframe time fill is transmitted. In response to SRES3 an XPR3 interrupt is generated. This command can be used by the CPU to abort a frame currently in transmission. Common Configuration Register 3 (Read/Write) Value after reset: 00H 7 0 CCR3 RADD2 RCRC2 XCRC2 ITF2 XMFA2 RADD2 Receive Address Pushed to RFIFO2 RFT12 RFT02 (8B) If this bit is set, the received HDLC channel 2 address information (1 or 2 bytes, depending on the address mode selected via MODE2.MDS02) is pushed to RFIFO2. This function is applicable in non-auto mode and transparent mode 1. Data Sheet 391 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RCRC2 Receive CRC ON/OFF - HDLC Channel 2 Only applicable in non-auto mode. If this bit is set, the received CRC checksum is written to RFIFO2 (CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in the received frame, is followed in the RFIFO2 by the status information byte (contents of register RSIS2). The received CRC checksum will additionally be checked for correctness. If non-auto mode is selected, the limits for “valid frame” check are modified. XCRC2 Transmit CRC ON/OFF - HDLC Channel 2 If this bit is set, the CRC checksum will not be generated internally. It has to be written as the last two bytes in the transmit FIFO (XFIFO2). The transmitted frame is closed automatically with a closing flag. ITF2 Interframe Time Fill - HDLC Channel 2 Determines the idle (= no data to be sent) state of the transmit data coming from the signaling controller. XMFA2 0= Continuous logical "1" is output 1= Continuous flag sequences are output ("01111110" bit patterns) Transmit Multiframe Aligned - HDLC Channel 2 Determines the synchronization between the framer and the corresponding signaling controller. RFT12, RFT02 0= The contents of the XFIFO2 is transmitted without multiframe alignment. 1= The contents of the XFIFO2 is transmitted multiframe aligned. RFIFO2 Threshold Level - HDLC Channel 2 The size of the accessible part of RFIFO2 can be determined by programming these bits. The number of valid bytes after an RPF interrupt is given in the following table: RFT12 RFT02 Size of Accessible Part of RFIFO2 0 0 1 1 0 1 0 1 32 bytes (default value) 16 bytes 4 bytes 2 bytes The value of RFT(1:0)2 can be changed dynamically if reception is not running or after the current data block has been read, but before the command CMDR3.RMC2 is issued (interrupt controlled data transfer). Data Sheet 392 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Common Configuration Register 4 (Read/Write) Value after reset: 00H 7 0 CCR4 RADD3 RCRC3 XCRC3 ITF3 XMFA3 RADD3 Receive Address Pushed to RFIFO3 RFT13 RFT03 (8C) If this bit is set, the received HDLC channel 3 address information (1 or 2 bytes, depending on the address mode selected via MODE3.MDS03) is pushed to RFIFO3. This function is applicable in non-auto mode and transparent mode 1. RCRC3 Receive CRC ON/OFF - HDLC Channel 3 Only applicable in non-auto mode. If this bit is set, the received CRC checksum is written to RFIFO3 (CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in the received frame, is followed in the RFIFO3 by the status information byte (contents of register RSIS3). The received CRC checksum will additionally be checked for correctness. If non-auto mode is selected, the limits for “Valid Frame” check are modified. XCRC3 Transmit CRC ON/OFF - HDLC Channel 3 If this bit is set, the CRC checksum will not be generated internally. It has to be written as the last two bytes in the transmit FIFO (XFIFO3). The transmitted frame is closed automatically with a closing flag. ITF3 Interframe Time Fill - HDLC Channel 3 Determines the idle (= no data to be sent) state of the transmit data coming from the signaling controller. XMFA3 0= Continuous logical "1" is output 1= Continuous flag sequences are output ("01111110" bit patterns) Transmit Multiframe Aligned - HDLC Channel 3 Determines the synchronization between the framer and the corresponding signaling controller. Data Sheet 0= The contents of the XFIFO3 is transmitted without multiframe alignment. 1= The contents of the XFIFO3 is transmitted multiframe aligned. 393 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RFT13, RFT03 RFIFO3 Threshold Level - HDLC Channel 3 The size of the accessible part of RFIFO3 can be determined by programming these bits. The number of valid bytes after an RPF interrupt is given in the following table: RFT13 RFT03 Size of Accessible Part of RFIFO3 0 0 1 1 0 1 0 1 32 bytes (default value) 16 bytes 4 bytes 2 bytes The value of RFT13/03 can be changed dynamically if reception is not running or after the current data block has been read, but before the command CMDR4.RMC3 is issued (interrupt controlled data transfer). Common Configuration Register 5 (Read/Write) Value after reset: 00H 7 0 CCR5 SUET CSF AFX CR EPR (8D) Note: SUET, CSF and AFX are only valid, if SS7 mode is selected. CR and EPR are only valid, if PPR mode is selected. SUET CSF Signaling Unit Error Threshold - HDLC Channel 1 Defines the number of signaling units received in error that will cause an error rate high indication (ISR1.SUEX). 0= Threshold 64 errored signaling units 1= Threshold 32 errored signaling units Compare Status Field - HDLC Channel 1 If the status fields of consecutive LSSUs are equal, only the first is stored and every following is ignored. Data Sheet 0= Compare disabled. 1= Compare enabled. 394 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers AFX Automatic FISU Transmission - HDLC Channel 1 After the contents of the transmit FIFO (XFIFO) has been transmitted completely, FISUs are transmitted automatically. These FISUs contain the FSN and BSO of the last transmitted signaling unit (provided in XFIFO). CR 0= Automatic FISU transmission disabled. 1= Automatic FISU transmission enabled. Command Response - HDLC Channel 1 Reflects the status of the CR bit in the SAPI octet transmitted during Periodical Performance Report (PPR), if CCR5.EPR = 1. EPR 0= CR bit = 0 1= CR bit = 1 Enable Periodical Performance Report (PPR) - HDLC Channel 1 If the periodical performance report is to be used, an HDLC format must be selected by MODE.MDS(2:0). 0 = PPR disabled. 1= PPR enabled. Mode Register 2 (Read/Write) Value after reset: 00H 7 MODE2 MDS22 MDS2(2:0) 0 MDS21 MDS20 HRAC2 DIV2 (8E) Mode Select - HDLC Channel 2 The operating mode of the HDLC controller is selected. 000 = Reserved 001 = Reserved 010 = One-byte address comparison mode (RAL1, 2) 011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2) 100 = No address comparison 101 = One-byte address comparison mode (RAH1, 2) 110 = Reserved 111 = No HDLC framing mode 1 Data Sheet 395 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers HRAC2 Receiver Active - HDLC Channel 2 Switches the HDLC receiver to operational or inoperational state. DIV2 0= Receiver inactive 1= Receiver active Data Inversion - HDLC Channel 2 Setting this bit will invert the internal generated HDLC data stream. 0= Normal operation, HDLC data stream not inverted 1= HDLC data stream inverted Mode Register 3 (Read/Write) Value after reset: 00H 7 MODE3 MDS32 MDS3(2:0) 0 MDS31 MDS30 HRAC3 DIV3 (8F) Mode Select - HDLC Channel 3 The operating mode of the HDLC controller is selected. 000 = Reserved 001 = Reserved 010 = One-byte address comparison mode (RAL1, 2) 011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2) 100 = No address comparison 101 = One-byte address comparison mode (RAH1, 2) 110 = Reserved 111 = No HDLC framing mode 1 HRAC3 Receiver Active - HDLC Channel 3 Switches the HDLC receiver to operational or inoperational state. Data Sheet 0= Receiver inactive 1= Receiver active 396 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers DIV3 Data Inversion - HDLC Channel 3 Setting this bit will invert the internal generated HDLC data stream. 0= Normal operation, HDLC data stream not inverted 1= HDLC data stream inverted Global Clock Mode Register 1 (Read/Write) Value after reset: 00H 7 GCM1 0 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 7 6 5 4 3 2 1 0 PHD_E1(7:0) (92) Frequency Adjust for E1 For details see calculation formulas below. Global Clock Mode Register 2 (Read/Write) Value after reset: 00H 7 GCM2 0 DVM_E1 DVM_E1 DVM_E1 VFREQ_ PHD_E1 PHD_E1 PHD_E1 PHD_E1 2 1 0 EN 11 10 9 8 PHD_E1(11:8) (93) Frequency Adjust for E1 For details see calculation formulas below. VFREQ_EN Data Sheet Variable Frequency Enable 0= Fixed clock frequency of 2.048 (E1) or 1.544 MHz (T1/J1) 1= Variable master clock frequency 397 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers DVM_E1(2:0) Divider Mode for E1 000 = Not valid 001 = Divide by DIV_E1 = 3 010 = Divide by DIV_E1 = 4 1/6 011 = Divide by DIV_E1 = 4 100 = Divide by DIV_E1 = 5.5 101 = Divide by DIV_E1 = 5 1/3 110 = Divide by DIV_E1 = 5 2/3 111 = Not valid Global Clock Mode Register 3 (Read/Write) Value after reset: 00H 7 GCM3 0 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 7 6 5 4 3 2 1 0 PHD_T1(7:0) (94) Frequency Adjust for T1 For details see calculation formulas below. Data Sheet 398 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Global Clock Mode Register 4 (Read/Write) Value after reset: 00H 7 GCM4 0 DVM_T1 DVM_T1 DVM_T1 2 1 0 PHD_T1(11:8) 0 PHD_T1 PHD_T1 PHD_T1 PHD_T1 11 10 9 8 (95) Frequency Adjust for T1 For details see calculation formulas below. DVM_T1(2:0) Divider Mode for T1 000 = Not valid 001 = Divide by DIV_T1 = 3 010 = Divide by DIV_T1 = 4 1/6 011 = Divide by DIV_T1 = 4 100 = Divide by DIV_T1 = 5.5 101 = Divide by DIV_T1 = 5 1/3 110 = Divide by DIV_T1 = 5 2/3 111 = Not valid GCM4.4 reserved Must be cleared. Data Sheet 399 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Global Clock Mode Register 5 (Read/Write) Value after reset: 00H 7 GCM5 0 MCLK_ LOW MCLK_LOW PLL_M(0:4) PLL_M 4 PLL_M 3 PLL_M 2 PLL_M 1 PLL_M 0 (96) Master Clock Range Low 0= Master clock frequency divided by (PLL_M+1) is greater than or equal 1.5 MHz 1= Master clock frequency divided by (PLL_M+1) is less than 1.5 MHz PLL Dividing Factor M For details see calculation formulas below. Note: Write operations to GCM5 initiate a PLL reset (see below). Global Clock Mode Register 6 (Read/Write) Value after reset: 00H 7 GCM6 PLL_N(4:0) 0 PLL_N 4 PLL_N 3 PLL_N 2 PLL_N 1 PLL_N 0 (97) PLL Dividing Factor N For details see calculation formulas below. Note: Write operations to GCM6 initiate a PLL reset (see below). Data Sheet 400 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Flexible Clock Mode Settings If flexible master clock mode is used (VFREQ_EN = 1), the according register settings can be calculated as follows (a windows-based program for automatic calculation is available, see Chapter 13.3 on page 481). For some of the standard frequencies see the table below. 1. PLL_M and PLL_N must fulfill the equations: a. 1.5 MHz ≤ fMCLK / (PLL_M+1) ≤ 2.048 MHz b. If (a.) is not possible, set MCLK_LOW and fulfill 1.02 MHz ≤ fMCLK / (PLL_M+1) ≤ 1.5 MHz c. 65 MHz ≤ fMCLK × (2×PLL_N+2) / (PLL_M+1) ≤ 69.7 MHz (as high as possible within this range) 2. Selection of dividing mode to best fulfill: foutE1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_E1 (target E1: 16.384 MHz) foutT1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_T1 (target T1: 12.352 MHz) Though the target frequency might not be met directly, the dividing mode has to be selected to reach a frequency, which is as near as possible to the target frequency. 3. Calculation of correction value (frequency mismatch correction) PHD_E1 = 6 × 4096 × [DIV_E1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/16.384 MHz)] PHD_T1 = 6 × 4096 × [DIV_T1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/12.352 MHz)] The result of these equations will be in the range of -2048 to +2047. Negative values are represented in 2s-complement format (e.g. -2000D = 830H; +2000D = 7D0H). Table 66 Clock Mode Register Settings for E1 or T1/J1 fMCLK [MHz] GCM1 GCM2 GCM3 GCM4 GCM5 GCM6 1.544 F0H 51H 00H 80H 00H 15H 2.048 00H 58H D2H C2H 00H 10H 8.192 00H 58H D2H C2H 03H 10H 10.000 90H 51H 81H 8FH 04H 10H 12.352 F0H 51H 00H 80H 07H 15H Data Sheet 401 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Transmit FIFO 2 (Write) Value after reset: 00H 7 0 XFIFO2 XF7 XF0 (9C) XFIFO2 XF15 XF8 (9D) XF(15:0) Transmit FIFO - HDLC Channel 2 The function is equivalent to XFIFO. Transmit FIFO 3 (Write) Value after reset: 00H 7 0 XFIFO3 XF7 XF0 (9E) XFIFO3 XF15 XF8 (9F) XF(15:0) Transmit FIFO - HDLC Channel 3 The function is equivalent to XFIFO. Time Slot Even/Odd Select (Read/Write) Value after reset: 00H 7 TSEO 0 EO31 EO30 EO21 EO20 EO11 EO10 (A0) HDLC protocol data can be sent in even, odd or both frames of a multiframe. Even frames are frame number 2, 4, and so on, odd frames are frame number 1, 3, and so on. The selection refers to receive and transmit direction as well. Each multiframe starts with an odd frame and ends with an even frame. By default all frames are used for HDLC reception and transmission. Note: The different HDLC channels have to be configured to use different time slots, bit positions or frames. Data Sheet 402 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers EO1(1:0) Even/Odd frame selection - HDLC Channel 1 Channel 1 HDLC protocol data can be sent in even, odd or both frames of a multiframe. 00 = Even and odd frames 01 = Odd frames only 10 = Even frames only 11 = Undefined EO2(1:0) Even/Odd frame selection - HDLC Channel 2 Channel 2 HDLC protocol data can be sent in even, odd or both frames of a multiframe. 00 = Even and odd frames 01 = Odd frames only 10 = Even frames only 11 = Undefined EO3(1:0) Even/Odd frame selection - HDLC Channel 3 Channel 3 HDLC protocol data can be sent in even, odd or both frames of a multiframe. 00 = Even and odd frames 01 = Odd frames only 10 = Even frames only 11 = Undefined Time Slot Bit Select 1 (Read/Write) Value after reset: FFH 7 TSBS1 TSB17 TSB1(7:0) = 0 TSB16 TSB15 TSB14 TSB13 TSB12 TSB11 TSB10 (A1) Time Slot Bit Selection - HDLC Channel 1 Only bits selected by this register are used for HDLC channel 1 in selected time slots. Time slot selection is done by setting the appropriate bits in registers TTR(4:1) and RTR(4:1) independently for receive and transmit direction. Bit selection is common to receive and transmit direction. By default all bit positions within the selected time slot(s) are enabled. TSB1x = 0 to bit position x in selected time slot(s) is not used for HDLC channel 1 reception and transmission. Data Sheet 403 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers TSB1x = 1 to bit position x in selected time slot(s) is used for HDLC channel 1 reception and transmission. Time Slot Bit Select 2 (Read/Write) Value after reset: FFH 7 TSBS2 TSB27 TSB2(7:0) 0 TSB26 TSB25 TSB24 TSB23 TSB22 TSB21 TSB20 (A2) Time Slot Bit Selection - HDLC Channel 2 Only bits selected by this register are used for HDLC channel 2 in selected time slots. Time slot selection is done by setting the appropriate bits in register TSS2. Bit selection is common to receive and transmit direction. By default all bit positions within the selected time slot are enabled. TSB2x=0 to bit position x in selected time slot(s) is not used for HDLC channel 2 reception and transmission. TSB2x=1 to bit position x in selected time slot(s) is used for HDLC channel 2 reception and transmission. Time Slot Bit Select 3 (Read/Write) Value after reset: FFH 7 TSBS3 TSB37 TSB3(7:0) 0 TSB36 TSB35 TSB34 TSB33 TSB32 TSB31 TSB30 A3) Time Slot Bit Selection - HDLC Channel 3 Only bits selected by this register are used for HDLC channel 3 in selected time slots. Time slot selection is done by setting the appropriate bits in register TSS3. Bit selection is common to receive and transmit direction. By default all bit positions within the selected time slot are enabled. TSB3x=0 to bit position x in selected time slot(s) is not used for HDLC channel 3 reception and transmission. TSB3x=1 to bit position x in selected time slot(s) is used for HDLC channel 3 reception and transmission. Data Sheet 404 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Time Slot Select 2 (Read/Write) Value after reset: 00H 7 0 TSS2 TSS24 TSS2(4:0) TSS23 TSS22 TSS21 TSS20 (A4) Time Slot Selection Code - HDLC Channel 2 Defines the time slot used by HDLC channel 2. 00000 =No time slot selected 00001 =Time slot 1 ... 11111 =Time slot 31 Note: Different HDLC channels must use different time slots. Time Slot Select 3 (Read/Write) Value after reset: 00H 7 0 TSS3 TSB3(4:0) TSS34 TSS33 TSS32 TSS31 TSS30 (A5) Time Slot Selection Code - HDLC Channel 3 Defines the time slot used by HDLC channel 3. 00000 =No time slot selected 00001 =Time slot 1 ... 11111 =Time slot 31 Note: Different HDLC channels must use different time slots. Data Sheet 405 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Test Pattern Control Register 0 (Read/Write) Value after reset: 00H 7 TPC0 FRA Data Sheet 0 FRA (A8) Framed/Unframed Selection 0= PRBS is generated/monitored unframed. Framing information is overwritten by the generator. 1= PRBS is generated/monitored framed. Time slot 0 is not overwritten by the generator and not observed by the monitor. 406 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 10.3 T1/J1 Status Register Addresses Table 67 T1/J1 Status Register Address Arrangement Address Register Type Comment Page 00 RFIFO R Receive FIFO 409 01 RFIFO R Receive FIFO 409 49 RBD R Receive Buffer Delay 409 4A VSTR R Version Status Register 410 4B RES R Receive Equalizer Status 410 4C FRS0 R Framer Receive Status 0 411 4D FRS1 R Framer Receive Status 1 413 4E FRS2 R Framer Receive Status 2 415 50 FECL R Framing Error Counter Low 416 51 FECH R Framing Error Counter High 416 52 CVCL R Code Violation Counter Low 417 53 CVCH R Code Violation Counter High 417 54 CECL R CRC Error Counter Low 418 55 CECH R CRC Error Counter High 418 56 EBCL R Errored Block Counter Low 419 57 EBCH R Errored Block Counter High 419 58 BECL R Bit Error Counter Low 420 59 BECH R Bit Error Counter High 420 5A COEC R COFA Event Counter 421 5C RDL1 R Receive DL-Bit Register 1 422 5D RDL2 R Receive DL-Bit Register 2 422 5E RDL3 R Receive DL-Bit Register 3 423 62 RSP1 R Receive Signaling Pointer 1 423 63 RSP2 R Receive Signaling Pointer 2 423 64 SIS R Signaling Status Register 424 65 RSIS R Receive Signaling Status Register 425 66 RBCL R Receive Byte Control Low 427 67 RBCH R Receive Byte Control High 427 68 ISR0 R Interrupt Status Register 0 428 Data Sheet 407 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Table 67 T1/J1 Status Register Address Arrangement (cont’d) Address Register Type Comment Page 69 ISR1 R Interrupt Status Register 1 430 6A ISR2 R Interrupt Status Register 2 431 6B ISR3 R Interrupt Status Register 3 433 6C ISR4 R Interrupt Status Register 4 434 6D ISR5 R Interrupt Status Register 5 436 6E GIS R Global Interrupt Status 437 70 RS1 R Receive Signaling Register 1 438 71 RS2 R Receive Signaling Register 2 438 72 RS3 R Receive Signaling Register 3 438 73 RS4 R Receive Signaling Register 4 438 74 RS5 R Receive Signaling Register 5 438 75 RS6 R Receive Signaling Register 6 438 76 RS7 R Receive Signaling Register 7 438 77 RS8 R Receive Signaling Register 8 438 78 RS9 R Receive Signaling Register 9 438 79 RS10 R Receive Signaling Register 10 438 7A RS11 R Receive Signaling Register 11 438 7B RS12 R Receive Signaling Register 12 438 90 RBC2 R Receive Byte Count Register 2 439 91 RBC3 R Receive Byte Count Register 3 439 98 SIS2 R Signaling Status Register 2 439 99 RSIS2 R Receive Signaling Status Register 2 440 9A SIS3 R Signaling Status Register 3 9B RSIS3 R Receive Signaling Status Register 3 443 9C RFIFO2 R Receive FIFO 2 445 9D RFIFO2 R Receive FIFO 2 445 9E RFIFO3 R Receive FIFO 3 445 9F RFIFO3 R Receive FIFO 3 445 EC WID R Identification Register 445 Data Sheet 408 442 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers 10.4 Detailed Description of T1/J1 Status Registers Receive FIFO - HDLC Channel 1 (Read) 7 0 RFIFO RF7 RF0 (00) RFIFO RF15 RF8 (01) Reading data from RFIFO can be done in an 8-bit (byte) or 16-bit (word) access depending on the selected bus interface mode. The LSB is received first from the serial interface. The size of the accessible part of RFIFO is determined by programming the bits CCR1.RFT(1:0) (RFIFO threshold level). It can be reduced from 32 bytes (reset value) down to 2 bytes (four values: 32, 16, 4, 2 bytes). Data Transfer Up to 32 bytes/16 words of received data can be read from the RFIFO following a RPF or a RME interrupt. RPF Interrupt: A fixed number of bytes/words to be read (32, 16, 4, 2 bytes). The message is not yet complete. RME Interrupt: The message is completely received. The number of valid bytes is determined by reading the RBCL, RBCH registers. RFIFO is released by issuing the RMC (Receive Message Complete) command. Receive Buffer Delay (Read) 7 RBD RBD(5:0) 0 RBD5 RBD4 RBD3 RBD2 RBD1 RBD0 (49) Receive Elastic Buffer Delay These bits informs the user about the current delay (in time slots) through the receive elastic buffer. The delay is updated every 386 or 193 bits (SIC1.RBS(1:0)). Before reading this register the user has to set bit DEC.DRBD in order to halt the current value of this register. After reading RBD updating of this register is enabled. Not valid if the receive buffer is bypassed. 000000 = Delay < 1 time slot ... 111111 = Delay > 63 time slots Data Sheet 409 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Version Status Register (Read) VSTR 7 0 VN7 VN0 VN(7:0) (4A) Version Number of Chip 00H =Version 1.2 Receive Equalizer Status (Read) 7 RES EV(1:0) EV1 0 EV0 RES4 RES3 RES2 RES1 RES0 (4B) Equalizer Status Valid These bits informs the user about the current state of the receive equalization network. Only valid if LIM1.EQON is set. 00 = Equalizer status not valid, still adapting 01 = Equalizer status valid 10 = Equalizer status not valid 11 = Equalizer status valid but high noise floor RES(4:0) Receive Equalizer Status The current line attenuation status in steps of about 1.4 dB are displayed in these bits. Only valid if bits EV(1:0) = 01 and LIM1.EQON = 1. Accuracy: ± 2 digits, based on temperature influence and noise amplitude variations. 00000 = Minimum attenuation: 0 dB ... 11001 = Maximum attenuation: -36 dB Data Sheet 410 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Receive Status Register 0 (Read) 7 FRS0 LOS LOS 0 AIS LFA RRA LMFA FSRF (4C) Loss-of-Signal (Red Alarm) Detection: This bit is set when the incoming signal has “no transitions“ (analog interface) or logical zeros (digital interface) in a time interval of T consecutive pulses, where T is programmable by PCD register: Total account of consecutive pulses: 16 < T < 4096. Analog interface: The receive signal level where “no transition” is declared is defined by the programmed value of LIM1.RIL(2:0). Recovery: Analog interface: The bit is reset in short-haul mode when the incoming signal has transitions with signal levels greater than the programmed receive input level (LIM1.RIL(2:0)) for at least M pulse periods defined by register PCR in the PCD time interval. In long-haul mode additionally bit RES.6 must be set for at least 250 µs. Digital interface: The bit is reset when the incoming data stream contains at least M ones defined by register PCR in the PCD time interval. With the rising edge of this bit an interrupt status bit (ISR2.LOS) is set. For additionally recovery conditions refer also to register LIM2.LOS1. The bit is set during alarm simulation and reset if FRS2.ESC = 0, 3, 4, 6,7 and no alarm condition exists. AIS Alarm Indication Signal (Blue Alarm) This bit is set when the conditions defined by bit FMR4.AIS3 are detected. The flag stays active for at least one multiframe. With the rising edge of this bit an interrupt status bit (ISR2.AIS) is set. It is reset with the beginning of the next following multiframe if no alarm condition is detected. The bit is set during alarm simulation and reset if FRS2.ESC = 0, 3, 4, 7 and no alarm condition exists. Data Sheet 411 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers LFA Loss of Frame Alignment The flag is set if pulseframe synchronization has been lost. The conditions are specified by bit FMR4.SSC(1:0). Setting this bit causes an interrupt (ISR2.LFA). The flag is cleared when synchronization has been regained. Additionally interrupt status ISR2.FAR is set with clearing this bit. RRA Receive Remote Alarm (Yellow Alarm) The flag is set after detecting remote alarm (yellow alarm). Conditions for setting/resetting are defined by bit RC0.RRAM. With the rising edge of this bit an interrupt status bit ISR2.RA is set. With the falling edge of this bit an interrupt status bit ISR2.RAR is set. The bit is set during alarm simulation and reset if FRS2.ESC = 0, 3, 4,5,7 and no alarm condition exists. LMFA Loss Of Multiframe Alignment Set in F12 or F72 format when 2 out of 4 (or 5 or 6) multiframe alignment patterns are incorrect. Additionally the interrupt status bit ISR2.LMFA is set. Cleared after multiframe synchronization has been regained. With the falling edge of this bit an interrupt status bit ISR2.MFAR is generated. FSRF Frame Search Restart Flag Toggles when no framing candidate (pulse framing or multiframing) is found and a new frame search is started. Data Sheet 412 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Receive Status Register 1 (Read) 7 FRS1 EXZD EXZD 0 PDEN LLBDD LLBAD XLS XLO (4D) Excessive Zeros Detected Significant only if (FMR2.EXZE = 1). excessive zeros detection is enabled Set after detecting of more than 7 (B8ZS code) or more than 15 (AMI code) contiguous zeros in the received bit stream. This bit is cleared on read. PDEN Pulse-Density Violation Detected The pulse-density of the received data stream is below the requirement defined by ANSI T1. 403 or more than 14 consecutive zeros are detected. With the violation of the pulse-density this bit is set and remains active until the pulse-density requirement is fulfilled for 23 consecutive "1"-pulses. Additionally an interrupt status ISR0.PDEN is generated with the rising edge of PDEN. LLBDD Line Loop-Back Deactivation Signal Detected This bit is set in case of the LLB deactivate signal is detected and then received over a period of more than 33,16 ms with a bit error rate less than 10-2. The bit remains set as long as the bit error rate does not exceed 10-2. If framing is aligned, the first bit position of any frame is not taken into account for the error rate calculation. Any change of this bit causes an LLBSC interrupt. LLBAD Line Loop-Back Activation Signal Detected/PRBS Status Depending on bit LCR1.EPRM the source of this status bit changed. LCR1.EPRM = 0: This bit is set in case of the LLB activate signal is detected and then received over a period of more than 33,16 ms with a bit error rate less than 10-2. The bit remains set as long as the bit error rate does not exceed 10-2. If framing is aligned, the first bit position of any frame is not taken into account for the error rate calculation. Any change of this bit causes an LLBSC interrupt. Data Sheet 413 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers PRBS Status LCR1.EPRM = 1: The current status of the PRBS synchronizer is indicated in this bit. It is set high if the synchronous state is reached even in the presence of a bit error rate of up to 10-3. A data stream containing all zeros or all ones with/without framing bits is also a valid pseudo-random binary sequence. XLS Transmit Line Short Significant only if the ternary line interface is selected by LIM1.DRS = 0. XLO Data Sheet 0= Normal operation. No short is detected. 1= The XL1 and XL2 are shortened for at least 3 pulses. As a reaction of the short the pins XL1 and XL2 are automatically forced into a high-impedance state if bit XPM2.DAXLT is reset. After 128 consecutive pulse periods the outputs XL1/2 are activated again and the internal transmit current limiter is checked. If a short between XL1/2 is still further active the outputs XL1/2 are in high-impedance state again. When the short disappears pins XL1/2 are activated automatically and this bit is reset. With any change of this bit an interrupt ISR1.XLSC is generated. In case of XPM2.XLT is set this bit is frozen. Transmit Line Open 0= Normal operation 1= This bit is set if at least 32 consecutive zeros were sent on pins XL1/XL2 or XDOP/XDON. This bit is reset with the first transmitted pulse. With the rising edge of this bit an interrupt ISR1.XLSC is set. In case of XPM2.XLT is set this bit is frozen. 414 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Framer Receive Status Register 2 (Read) 7 FRS2 0 ESC2 ESC(2:0) ESC1 ESC0 (4E) Error Simulation Counter This three-bit counter is incremented by setting bit FMR0.SIM. The state of the counter determines the function to be tested. For complete checking of the alarm indications, eight simulation steps are necessary (FRS2.ESC = 0 after a complete simulation). Table 68 Alarm Simulation States Tested Alarms ESC(2:0) = 0 1 2 3 4 5 6 LFA × × LMFA × × 7 × RRA (bit2 = 0) × RRA (S-bit frame 12) × RRA (DL-pattern) × LOS1) × × × EBC2) (F12,F72) (×) EBC2) (only ESF) × × × (×) AIS1) × × × × × FEC2) (×) CVC × × × CEC (only ESF) × × × RSP × × × RSN × XSP × XSN × BEC1) × × COEC × × 1) only active during FMR0.SIM = 1 2) FEC is counting +2 while EBC is counting +1 if the framer is in synchronous state; if asynchronous in state 2 but synchronous in state 6, counters are incremented during state 6 Data Sheet 415 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Some of these alarm indications are simulated only if the FALC56 is configured in the appropriate mode. At simulation steps 0, 3, 4, and 7 pending status flags are reset automatically and clearing of the error counters and interrupt status registers ISR(5:0) should be done. Incrementing the simulation counter should not be done at time intervals shorter than 1.5 ms (F4, F12, F72) or 3 ms (ESF). Otherwise, reactions of initiated simulations might occur at later steps. Control bit FMR0.SIM has to be held stable at high or low level for at least one receive clock period before changing it again. Framing Error Counter (Read) FECL FECH FE(15:0) 7 0 FE7 FE0 7 0 FE15 FE8 (50) (51) Framing Errors This 16-bit counter is incremented when incorrect FT and FS-bits in F4, F12 and F72 format or incorrect FAS-bits in ESF format are received. Framing errors are counted during synchronous state only (but even if multiframe synchronous state is not reached yet). The error counter does not roll over. During alarm simulation, the counter is incremented twice. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DFEC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DFEC is automatically reset with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 416 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Code Violation Counter (Read) CVCL CVCH CV(15:0) 7 0 CV7 CV0 7 0 CV15 CV8 (52) (53) Code Violations No function if NRZ or CMI code has been enabled. If the B8ZS code (bit FMR0.RC(1:0) = 11) is selected, the 16-bit counter is incremented by detecting violations which are not due to zero substitution. If FMR2.EXZE is set, additionally excessive zero strings (more than 7 contiguous zeros) are detected and counted. If simple AMI coding is enabled (FMR0.RC0/1 = 10) all bipolar violations are counted. If FMR2.EXZE is set, additionally excessive zero strings (more than 15 contiguous zeros) are detected and counted. The error counter does not roll over. During alarm simulation, the counter is incremented continuously with every second received bit. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DCVC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DCVC is automatically reset with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 417 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers CRC Error Counter (Read) CECL CECH CR(15:0) 7 0 CR7 CR0 7 0 CR15 CR8 (54) (55) CRC Errors No function if CRC6 procedure or ESF format are disabled. In ESF mode, the 16-bit counter is incremented when a multiframe has been received with a CRC error. CRC errors are not counted during asynchronous state. The error counter does not roll over. During alarm simulation, the counter is incremented once per multiframe. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DCEC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DCEC is automatically reset with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 418 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Errored Block Counter (Read) 7 0 EBC7 EBC0 7 0 EBC15 EBC8 EBCL EBCH EBC(15:0) (56) (57) Errored Block Counter In ESF format this 16-bit counter is incremented once per multiframe if a multiframe has been received with a CRC error or an errored frame alignment has been detected. CRC and framing errors are not counted during asynchronous state. The error counter does not roll over. In F4/12/72 format an errored block contain 4/12 or 72 frames. Incrementing is done once per multiframe if framing errors has been detected. During alarm simulation, the counter is incremented in ESF format once per multiframe and in F4/12/72 format only one time. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the error counter bit DEC.DEBC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DEBC is automatically reset with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 419 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Bit Error Counter (Read) 7 0 BEC7 BEC0 7 0 BEC15 BEC8 BECL BECH BEC(15:0) (58) (59) Bit Error Counter If the PRBS monitor is enabled by LCR1.EPRM = 1 this 16-bit counter is incremented with every received PRBS bit error in the PRBS synchronous state FRS1.LLBAD = 1. The error counter does not roll over. During alarm simulation, the counter is incremented continuously with every second received bit. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the PRBS bit error counter bit DEC.DBEC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DBEC is automatically reset with reading the error counter high byte. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 420 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers COFA Event Counter (Read) 7 COEC COE(7:2) 0 COE7 COE2 COE1 COE0 (5A) Multiframe Counter If GCR.ECMC = 1 this 6 bit counter increments with each multiframe period in the asynchronous state FRS0.LFA/LMFA = 1. The error counter does not roll over. COE(1:0) Change of Frame Alignment Counter If GCR.ECMC = 1 this 2 bit counter increments with each detected change of frame/multiframe alignment. The error counter does not roll over. During alarm simulation, the counter is incremented once per multiframe. Clearing and updating the counter is done according to bit FMR1.ECM. If this bit is reset the error counter is permanently updated in the buffer. For correct read access of the event counter bit DEC.DCOEC has to be set. With the rising edge of this bit updating the buffer is stopped and the error counter is reset. Bit DEC.DCOEC is automatically reset with reading the error counter high byte on address 5BH. Data read on 5BH is not defined. If FMR1.ECM is set every second (interrupt ISR3.SEC) the error counter is latched and then automatically reset. The latched error counter state should be read within the next second. Data Sheet 421 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive DL-Bit Register 1 (Read) 7 RDL1 RDL17 RDL1(7:0) 0 RDL16 RDL15 RDL14 RDL13 RDL12 RDL11 RDL10 (5C) Receive DL-Bit Only valid if F12, F24 or F72 format is enabled. The received FS/DL-Bits are shifted into this register. RDL10 is received in frame 1 and RDL17 in frame 15, if F24 format is enabled. RDL10 is received in frame 26 and RDL17 in frame 40, if F72 format is enabled. In F12 format the FS-Bits of a complete multiframe is stored in this register. RDL10 is received in frame 2 and RDL15 in frame 12. This register is updated with every receive multiframe begin interrupt ISR0.RMB. Receive DL-Bit Register 2 (Read) 7 RDL2 RDL27 RDL2(7:0) 0 RDL26 RDL25 RDL24 RDL23 RDL22 RDL21 RDL20 (5D) Receive DL-Bit Only valid if F24 or F72 format is enabled. The received DL-Bits are shifted into this register. RDL20 is received in frame 17 and RDL23 in frame 23, if F24 format is enabled. RDL20 is received in frame 42 and RDL27 in frame 56, if F72 format is enabled. This register is updated with every receive multiframe begin interrupt ISR0.RMB. Data Sheet 422 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive DL-Bit Register 3 (Read) 7 RDL3 RDL37 RDL3(7:0) 0 RDL36 RDL35 RDL34 RDL33 RDL32 RDL31 RDL30 (5E) Receive DL-Bit Only valid if F72 format is enabled. The received DL-Bits are shifted into this register. RDL30 is received in frame 58 and RDL37 in frame 72, if F72 format is enabled. This register is updated with every receive multiframe begin interrupt ISR0.RMB. Receive Signaling Pointer 1 (Read) Value after reset: 00H 7 RSP1 RS8C RS(8:1)C 0 RS7C RS6C RS5C RS4C RS3C RS2C RS1C (62) Receive Signaling Register RS(8:1) Changed A one in each bit position indicates that the received signaling data in the corresponding RS(8:1) registers are updated. Bit RS1C is the pointer for register RS1, while RS8C points to RS8. Receive Signaling Pointer 2 (Read) Value after reset: 00H 7 RSP2 RS(12:0)C 0 RS12C RS11C RS10C RS9C (63) Receive Signaling Register RS(12:9) Changed A one in each bit position indicates that the received signaling data in the corresponding RS(12:9) registers are updated. Bit RS9C is the pointer for register RS9, while RS12C points to RS12 Data Sheet 423 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Signaling Status Register (Read) 7 SIS XDOV XDOV 0 XFW XREP IVB RLI CEC SFS BOM (64) Transmit Data Overflow - HDLC Channel 1 More than 32 bytes have been written to the XFIFO. This bit is reset – by a transmitter reset command XRES or – when all bytes in the accessible half of the XFIFO have been moved in the inaccessible half. XFW Transmit FIFO Write Enable - HDLC Channel 1 Data can be written to the XFIFO. XREP Transmission Repeat - HDLC Channel 1 Status indication of CMDR.XREP. IVB RLI Invalid BOM Frame Received - HDLC Channel 1 0= Valid BOM frame (11111111, 0xxxxxx0) received. 1= Invalid BOM frame received. Receive Line Inactive - HDLC Channel 1 Neither flags as interframe time fill nor frames are received in the signaling time slot. CEC Command Executing 0= No command is currently executed, the CMDR register can be written to. 1= A command (written previously to CMDR) is currently executed, no further command can be temporarily written in CMDR register. Note: CEC is active at most 2.5 periods of the current system data rate. SFS Data Sheet Status Freeze Signaling 0= Freeze signaling status inactive. 1= Freeze signaling status active. 424 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers BOM Bit Oriented Message - HDLC Channel 1 Significant only in ESF frame format and auto switching mode is enabled. 0= HDLC mode 1= BOM mode Receive Signaling Status Register (Read) 7 RSIS VFR 0 RDO CRC16 RAB HA1 HA0 HFR LA (65) RSIS relates to the last received HDLC or BOM frame; it is copied into RFIFO when endof-frame is recognized (last byte of each stored frame). VFR Valid Frame - HDLC Channel 1 Determines whether a valid frame has been received. 1= Valid 0= Invalid An invalid frame is either – a frame which is not an integer number of 8 bits (n×8 bits) in length (e.g. 25 bits), or – a frame which is too short taking into account the operation mode selected by MODE (MDS(2:0)) and the selection of receive CRC on/off (CCR2.RCRC) as follows: • MDS(2:0) = 011 (16 bit Address), RCRC = 0: 4 bytes; RCRC = 1: 3 or 4 bytes • MDS(2:0) = 010 (8 bit Address), RCRC = 0: 3 bytes; RCRC = 1: 2 or 3 bytes Note: Shorter frames are not reported. RDO Receive Data Overflow - HDLC Channel 1 A data overflow has occurred during reception of the frame. Additionally, an interrupt can be generated (refer to ISR1.RDO/IMR1.RDO). CRC16 Data Sheet CRC16 Compare/Check - HDLC Channel 1 0= CRC check failed; received frame contains errors. 1= CRC check o.k.; received frame is error-free. 425 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RAB Receive Message Aborted - HDLC Channel 1 This bit is set in SS7 mode, if the maximum number of octets (272+7) is exceeded. The received frame was aborted from the transmitting station. According to the HDLC protocol, this frame must be discarded by the receiver station. HA1, HA0 High Byte Address Compare - HDLC Channel 1 Significant only if 2-byte address mode or SS7 mode has been selected. In operating modes which provide high byte address recognition, the FALC56 compares the high byte of a 2-byte address with the contents of two individually programmable registers (RAH1, RAH2) and the fixed values FEH and FCH (broadcast address). Depending on the result of this comparison, the following bit combinations are possible (SS7 support not active): 00 = RAH2 has been recognized 01 = Broadcast address has been recognized 10 = RAH1 has been recognized C/R = 0 (bit 1) 11 = RAH1 has been recognized C/R = 1 (bit 1) Note: If RAH1, RAH2 contain identical values, a match is indicated by "10" or "11". If Signaling System 7 support is activated (see MODE register), the bit functions are defined as follows: 00 = not valid 01 = Fill In signaling unit (FISU) detected 10 = Link status signaling unit (LSSU) detected 11 = Message signaling unit (MSU) detected HFR HDLC Frame Format - HDLC Channel 1 0= A BOM frame was received. 1= A HDLC frame was received. Note: Bits RSIS.(7:2) and RSIS.0 are not valid with a BOM frame. This means, if HFR = 0, all other bits of RSIS have to be ignored Not valid in SS7 mode. Bit HFR has to be ignored, if SS7 mode is selected. Data Sheet 426 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers LA Low Byte Address Compare - HDLC Channel 1 Significant in HDLC modes only. The low byte address of a 2-byte address field, or the single address byte of a 1-byte address field is compared to two registers. (RAL1, RAL2). 0= 1= RAL2 has been recognized RAL1 has been recognized Note: Not valid in SS7 mode. Bit LA has to be ignored, if SS7 mode is selected. Receive Byte Count Low - HDLC Channel 1 (Read) RBCL 7 0 RBC7 RBC0 (66) Together with RBCH, bits RBC(11:8), indicates the length of a received frame (1 to 4095 bytes). Bits RBC(4:0) indicate the number of valid bytes currently in RFIFO. These registers must be read by the CPU following a RME interrupt. Received Byte Count High - HDLC Channel 1 (Read) Value after reset: 000xxxxx 7 RBCH OV 0 OV RBC11 RBC10 RBC9 RBC8 (67) Counter Overflow - HDLC Channel 1 More than 4095 bytes received. RBC(11:8) Receive Byte Count - HDLC Channel 1 (most significant bits) Together with RBCL (bits RBC7...0) indicates the length of the received frame. Data Sheet 427 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Interrupt Status Register 0 (Read) Value after reset: 00H 7 ISR0 RME 0 RFS/BIV ISF RMB RSC CRC6 PDEN RPF (68) All bits are reset when ISR0 is read. If bit GCR.VIS is set, interrupt statuses in ISR0 are flagged although they are masked by register IMR0. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. RME Receive Message End - HDLC Channel 1 One complete message of length less than 32 bytes, or the last part of a frame at least 32 bytes long is stored in the receive FIFO, including the status byte. The complete message length can be determined reading the RBCH, RBCL registers, the number of bytes currently stored in RFIFO is given by RBC(4:0). Additional information is available in the RSIS register. RFS/BIV Receive Frame Start - HDLC Channel 1 This is an early receiver interrupt activated after the start of a valid frame has been detected, i.e. after an address match (in operation modes providing address recognition), or after the opening flag (transparent mode 0) is detected, delayed by two bytes. After a RFS interrupt, the contents of RAL1and RSIS.3-1 are valid and can be read by the CPU. BOM Frame Invalid - HDLC Channel 1 Only valid if CCR2.RBFE is set. When the BOM receiver left the valid BOM status (detecting 7 out of 10 equal BOM frames) this interrupt is generated. ISF Incorrect Sync Format - HDLC Channel 1 The FALC56 did not detect eight consecutive ones within 32 bits in BOM mode. Only valid if BOM receiver has been activated. RMB Receive Multiframe Begin This bit is set with the beginning of a received multiframe of the receive line timing. Data Sheet 428 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RSC Received Signaling Information Changed This interrupt bit is set during each multiframe in which signaling information on at least one channel changes its value from the previous multiframe. This interrupt only occurs in the synchronous state. The registers RS(12:1) should be read within the next 3 ms otherwise the contents is lost. CRC6 PDEN Receive CRC6 Error 0= No CRC6 error occurs. 1= The CRC6 check of the last received multiframe failed. Pulse-Density Violation The pulse-density violation of the received data stream defined by ANSI T1. 403 is violated. More than 14 consecutive zeros or less than N ones in each and every time window of 8×(N+1) data bits (N = 23) are detected. If GCR.SCI is set high this interrupt status bit is activated with every change of state of FRS1.PDEN. RPF Receive Pool Full - HDLC Channel 1 32 bytes of a frame have arrived in the receive FIFO. The frame is not yet received completely. Data Sheet 429 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Interrupt Status Register 1 (Read) 7 ISR1 CASE 0 RDO ALLS XDU XMB SUEX XLSC XPR (69) All bits are reset when ISR1 is read. If bit GCR.VIS is set, interrupt statuses in ISR1 are flagged although they are masked by register IMR1. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. CASE Transmit CAS Register Empty In ESF format this bit is set with the beginning of a transmitted multiframe related to the internal transmitter timing. In F12 and F72 format this interrupt occurs every 24 frames to inform the user that new bit robbing data may be written to the XS(12:1) registers. This interrupt is generated only if the serial signaling access on the system highway is not enabled. RDO Receive Data Overflow - HDLC Channel 1 This interrupt status indicates that the CPU did not respond fast enough to an RPF or RME interrupt and that data in RFIFO has been lost. Even when this interrupt status is generated, the frame continues to be received when space in the RFIFO is available again. Note: Whereas the bit RSIS.RDO in the frame status byte indicates whether an overflow occurred when receiving the frame currently accessed in the RFIFO, the ISR1.RDO interrupt status is generated as soon as an overflow occurs and does not necessarily pertain to the frame currently accessed by the processor. ALLS All Sent - HDLC Channel 1 This bit is set if the last bit of the current frame has been sent completely and XFIFO is empty. This bit is valid in HDLC mode only. XDU Transmit Data Underrun - HDLC Channel 1 Transmitted frame was terminated with an abort sequence because no data was available for transmission in XFIFO and no XME was issued. Note: Transmitter and XFIFO are reset and deactivated if this condition occurs. They are reactivated not before this interrupt status register has been read. Thus, XDU should not be masked by register IMR1. Data Sheet 430 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XMB Transmit Multiframe Begin This bit is set with the beginning of a transmitted multiframe related to the internal transmit line interface timing. SUEX Signaling Unit Error Threshold Exceeded - HDLC Channel 1 Masks the indication by interrupt that the selected error threshold for SS7 signaling units has been exceeded. 0= Signaling unit error count below selected threshold 1= Signaling unit error count exceeded selected threshold Note: XLSC SUEX is only valid, if SS7 mode is selected. If SUEX is caused by an aborted/invalid frame, the interrupt will be issued regularly until a valid frame is received (e.g. a FISU). Transmit Line Status Change XLSC is set with the rising edge of the bit FRS1.XLO or with any change of bit FRS1.XLS. The actual status of the transmit line monitor can be read from the FRS1.XLS and FRS1.XLO. XPR Transmit Pool Ready - HDLC Channel 1 A data block of up to 32 bytes can be written to the transmit FIFO. XPR enables the fastest access to XFIFO. It has to be used for transmission of long frames, back-to-back frames or frames with shared flags. Interrupt Status Register 2 (Read) 7 ISR2 FAR 0 LFA MFAR LMFA AIS LOS RAR RA (6A) All bits are reset when ISR2 is read. If bit GCR.VIS is set, interrupt statuses in ISR2 are flagged although they are masked by register IMR2. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. FAR Frame Alignment Recovery The framer has reached synchronization. Set with the falling edge of bit FRS0.LFA. It is set also after alarm simulation is finished and the receiver is still synchronous. Data Sheet 431 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers LFA Loss of Frame Alignment The framer has lost synchronization and bit FRS0.LFA is set. It is set during alarm simulation. MFAR Multiframe Alignment Recovery Set when the framer has reached multiframe alignment in F12 or F72 format. With the negative transition of bit FRS0.LMFA this bit is set. It is set during alarm simulation. LMFA Loss of Multiframe Alignment Set when the framer has lost the multiframe alignment in F12 or F72 format. With the positive transition of bit FRS0.LMFA this bit is set. It is set during alarm simulation. AIS Alarm Indication Signal (Blue Alarm) This bit is set when an alarm indication signal is detected and bit FRS0.AIS is set. If GCR.SCI is set high this interrupt status bit is activated with every change of state of FRS0.AIS. It is set during alarm simulation. LOS Loss-of-Signal (Red Alarm) This bit is set when a loss-of-signal alarm is detected in the received data stream and FRS0.LOS is set. If GCR.SCI is set high this interrupt status bit is activated with every change of state of FRS0.LOS. It is set during alarm simulation. RAR Remote Alarm Recovery Set if a remote alarm (yellow alarm) is cleared and bit FRS0.RRA is reset. It is set also after alarm simulation is finished and no remote alarm is detected. RA Remote Alarm A remote alarm (yellow alarm) is detected. Set with the rising edge of bit FRS0.RRA. It is set during alarm simulation. Data Sheet 432 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Interrupt Status Register 3 (Read) 7 ISR3 ES 0 SEC LLBSC RSN RSP (6B) All bits are reset when ISR3 is read. If bit GCR.VIS is set, interrupt statuses in ISR3 are flagged although they are masked by register IMR3. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. ES Errored Second This bit is set if at least one enabled interrupt source by ESM is set during the time interval of one second. Interrupt sources of ESM register: LFA FER CER AIS LOS CVE SLIP SEC = Loss of frame alignment detected = Framing error received = CRC error received = Alarm indication signal (blue alarm) = Loss-of-signal (red alarm) = Code violation detected = Transmit slip or receive slip positive/negative detected Second Timer The internal one-second timer has expired. The timer is derived from clock RCLK. LLBSC Line Loop-Back Status Change/PRBS Status Change Depending on bit LCR1.EPRM the source of this interrupt status changed: LCR1.EPRM = 0: This bit is set, if the LLB activate signal or the LLB deactivate signal is detected over a period of 33,16 ms with a bit error rate less than 10-2. The LLBSC bit is also set, if the current detection status is left, i.e., if the bit error rate exceeds 10-2. The actual detection status can be read from the FRS1.LLBAD and FRS1.LLBDD, respectively. PRBS Status Change LCR1.EPRM = 1: With any change of state of the PRBS synchronizer this bit is set. The current status of the PRBS synchronizer is indicated in FRS1.LLBAD. Data Sheet 433 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RSN Receive Slip Negative The frequency of the receive route clock is greater than the frequency of the receive system interface working clock based on 1.544 MHz. A frame is skipped. It is set during alarm simulation. RSP Receive Slip Positive The frequency of the receive route clock is less than the frequency of the receive system interface working clock based on 1.544 MHz. A frame is repeated. It is set during alarm simulation. Interrupt Status Register 4 (Read) 7 ISR4 XSP 0 XSN RME2 RFS2 RDO2 ALLS2 XDU2 RPF2 (6C) All bits are reset when ISR4 is read. If bit GCR.VIS is set, interrupt statuses in ISR4 are flagged although they are masked by register IMR4. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. XSP Transmit Slip Positive The frequency of the transmit clock is less than the frequency of the transmit system interface working clock based on 1.544 MHz. A frame is repeated. After a slip has performed writing of register XC1 is not necessary. XSN Transmit Slip Negative The frequency of the transmit clock is greater than the frequency of the transmit system interface working clock based on 1.544 MHz. A frame is skipped. After a slip has performed writing of register XC1 is not necessary. RME2 Receive Message End - HDLC Channel 2 One complete message of length less than 32 bytes, or the last part of a frame at least 32 bytes long is stored in the receive FIFO2, including the status byte. The complete message length can be determined reading register RBC2, the number of bytes currently stored in RFIFO2 is given by RBC2(6:0). Additional information is available in register RSIS2. Data Sheet 434 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RFS2 Receive Frame Start - HDLC Channel 2 This is an early receiver interrupt activated after the start of a valid frame has been detected, i.e. after an address match (in operation modes providing address recognition), or after the opening flag (transparent mode 0) is detected, delayed by two bytes. After an RFS2 interrupt, the contents of • RAL1 • RSIS2 bits 3 to 1 are valid and can be read by the CPU. RDO2 Receive Data Overflow - HDLC Channel 2 This interrupt status indicates that the CPU did not respond fast enough to an RPF2 or RME2 interrupt and that data in RFIFO2 has been lost. Even when this interrupt status is generated, the frame continues to be received when space in the RFIFO2 is available again. Note: Whereas the bit RSIS2.RDO2 in the frame status byte indicates whether an overflow occurred when receiving the frame currently accessed in the RFIFO2, the ISR4.RDO2 interrupt status is generated as soon as an overflow occurs and does not necessarily pertain to the frame currently accessed by the processor. ALLS2 All Sent - HDLC Channel 2 This bit is set if the last bit of the current frame has been sent completely and XFIFO2 is empty. This bit is valid in HDLC mode only. XDU2 Transmit Data Underrun - HDLC Channel 2 Transmitted frame was terminated with an abort sequence because no data was available for transmission in XFIFO2 and no XME2 was issued. Note: Transmitter and XFIFO2 are reset and deactivated if this condition occurs. They are reactivated not before this interrupt status register has been read. Thus, XDU2 should not be masked via register IMR4. RPF2 Receive Pool Full - HDLC Channel 2 32 bytes of a frame have arrived in the receive FIFO2. The frame is not yet completely received. Data Sheet 435 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Interrupt Status Register 5 (Read) 7 ISR5 XPR2 0 XPR3 RME3 RFS3 RDO3 ALLS3 XDU3 RPF3 (6D) All bits are reset when ISR5 is read. If bit GCR.VIS is set, interrupt statuses in ISR5 are flagged although they are masked via register IMR5. However, these masked interrupt statuses neither generate a signal on INT, nor are visible in register GIS. XPR2 Transmit Pool Ready - HDLC Channel 2 A data block of up to 32 bytes can be written to the transmit FIFO2. XPR2 enables the fastest access to XFIFO2. It has to be used for transmission of long frames, back-to-back frames or frames with shared flags. XPR3 Transmit Pool Ready - HDLC Channel 3 A data block of up to 32 bytes can be written to the transmit FIFO3. XPR3 enables the fastest access to XFIFO3. It has to be used for transmission of long frames, back-to-back frames or frames with shared flags. RME3 Receive Message End - HDLC Channel 3 One complete message of length less than 32 bytes, or the last part of a frame at least 32 bytes long is stored in the receive FIFO3, including the status byte. The complete message length can be determined reading register RBC3, the number of bytes currently stored in RFIFO3 is given by RBC3(6:0). Additional information is available in register RSIS3. RFS3 Receive Frame Start - HDLC Channel 3 This is an early receiver interrupt activated after the start of a valid frame has been detected, i.e. after an address match (in operation modes providing address recognition), or after the opening flag (transparent mode 0) is detected, delayed by two bytes. After an RFS2 interrupt, the contents of • RAL1 • RSIS3 bits 3 to 1 are valid and can be read by the CPU. Data Sheet 436 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers RDO3 Receive Data Overflow - HDLC Channel 3 This interrupt status indicates that the CPU did not respond fast enough to an RPF3 or RME3 interrupt and that data in RFIFO3 has been lost. Even when this interrupt status is generated, the frame continues to be received when space in the RFIFO3 is available again. Note: Whereas the bit RSIS3.RDO3 in the frame status byte indicates whether an overflow occurred when receiving the frame currently accessed in the RFIFO3, the ISR5.RDO3 interrupt status is generated as soon as an overflow occurs and does not necessarily pertain to the frame currently accessed by the processor. ALLS3 All Sent - HDLC Channel 3 This bit is set if the last bit of the current frame has been sent completely and XFIFO3 is empty. This bit is valid in HDLC mode only. XDU3 Transmit Data Underrun - HDLC Channel 3 Transmitted frame was terminated with an abort sequence because no data was available for transmission in XFIFO3 and no XME3 was issued. Note: Transmitter and XFIFO3 are reset and deactivated if this condition occurs. They are reactivated not before this interrupt status register has been read. Thus, XDU3 should not be masked via register IMR5. RPF3 Receive Pool Full - HDLC Channel 3 32 bytes of a frame have arrived in the receive FIFO3. The frame is not yet completely received. Global Interrupt Status Register (Read) Value after reset: 00H 7 GIS 0 ISR5 ISR4 ISR3 ISR2 ISR1 ISR0 (6E) This status register points to pending interrupts sourced by ISR(5:0). Data Sheet 437 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Signaling Register (Read) Value after reset: not defined Table 69 Receive Signaling Registers (T1/J1) 7 0 RS1 A1 B1 C1/A2 D1/B2 A2/A3 B2/B3 C2/A4 D2/B4 (70) RS2 A3/A5 B3/B5 C3/A6 D3/B6 A4/A7 B4/B7 C4/A8 D4/B8 (71) RS3 A5/A9 B5/B9 C5/A10 D5/B10 A6/A11 B6/B11 C6/A12 D6/B12 (72) RS4 A7/A13 B7/B13 C7/A14 D7/B14 A8/A15 B8/B15 C8/A16 D8/B16 (73) RS5 A9/A17 B9/B17 C9/A18 D9/B18 A10/A19 B10/B19 C10/A20 D10/B20 (74) RS6 A11/A21 B11/B21 C11/A22 D11/B22 A12/A23 B12/B23 C12/A24 D12/B24 (75) RS7 A13/A1 B13/B1 C13/A2 D13/B2 A14/A3 B14/B3 C14/A4 D14/B4 (76) RS8 A15/A5 B15/B5 C15/A6 D15/B6 A16/A7 B16/B7 C16/A8 D16/B8 (77) RS9 A17/A9 B17/B9 C17/A10 D17/B10 A18/A11 B18/B11 C18/A12 D18/B12 (78) RS10 A19/A13 B19/B13 C19/A14 D19/B14 A20/A15 B20/B15 C20/A16 D20/B16 (79) RS11 A21/A17 B21/B17 C21/A18 D21/B18 A22/A19 B22/B19 C22/A20 D22/B20 (7A) RS12 A23/A21 B23/B21 C23/A22 D23/B22 A24/A23 B24/B23 C24/A24 D24/B24 (7B) Receive Signaling Register 1 to 12 Each register contains the received bit robbing information for 8 DS0 channels. The received robbed bit signaling information of a complete ESF multiframe is compared to the previously received one. In F12/72 frame format the received signaling information of every 24 frames is compared to the previously received 24 frames. If the contents changed a Receive Signaling Changed interrupt ISR0.RSC is generated and informs the user that a new multiframe has to be read within the next 3 ms. Received data is stored in RS(12:1) registers. The RS1.7 is received in channel 1 frame 1 and RS12.0 in channel 24 frame 24 (ESF). If requests for reading the RS(12:1) registers are ignored, received data might get lost. Additionally a receive signaling data change pointer indicates an update of register RS(12:1). Refer also to register RSP(2:1). Access to RS(12:1) registers is only valid if the serial receive signaling access on the system highway is disabled. Data Sheet 438 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Byte Count Register 2 (Read) Value after reset: 00H 7 RBC2 OV2 OV2 0 RBC26 RBC25 RBC24 RBC23 RBC22 RBC21 RBC20 (90) Counter Overflow - HDLC Channel 2 RBC2(6:0) 0= Less than or equal to 128 bytes received 1= More than 128 bytes received Receive Byte Count - HDLC Channel 2 Indicates the length of a received frame. Receive Byte Count Register 3 (Read) Value after reset: 00H 7 RBC3 OV3 OV3 0 RBC36 RBC35 RBC34 RBC33 RBC32 RBC31 RBC30 (91) Counter Overflow - HDLC Channel 3 RBC3(6:0) 0= Less than or equal to 128 bytes received 1= More than 128 bytes received Receive Byte Count - HDLC Channel 3 Indicates the length of a received frame. Signaling Status Register 2 (Read) Value after reset: 00H 7 SIS2 XDOV2 XDOV2 0 XFW2 XREP2 RLI2 CEC2 (98) Transmit Data Overflow - HDLC Channel 2 More than 32 bytes have been written to the XFIFO2. This bit is reset – by a transmitter reset command XRES or – when all bytes in the accessible half of the XFIFO2 have been moved in the inaccessible half. Data Sheet 439 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers XFW2 Transmit FIFO Write Enable - HDLC Channel 2 Data can be written to the XFIFO2. XREP2 Transmission Repeat - HDLC Channel 2 Status indication of CMDR2.XREP2. RLI2 Receive Line Inactive - HDLC Channel 2 Neither flags as interframe time fill nor frames are received via the signaling time slot. CEC2 Command Executing - HDLC Channel 2 0= No command is currently executed, the CMDR3 register can be written to. 1= A command (written previously to CMDR3) is currently executed, no further command can be temporarily written in CMDR3 register. Note: CEC2 will be active up to 2.5 periods of the current system data rate. Receive Signaling Status Register 2 (Read) Value after reset: 00H 7 RSIS2 VFR2 0 RDO2 CRC162 RAB2 HA12 HA02 LA2 (99) RSIS2 relates to the last received HDLC channel 2 frame; it is copied into RFIFO2 when end-of-frame is recognized (last byte of each stored frame). VFR2 Valid Frame - HDLC Channel 2 Determines whether a valid frame has been received. 1= Valid 0= Invalid An invalid frame is either – a frame which is not an integer number of 8 bits (n × 8 bits) in length (e.g. 25 bits), or – a frame which is too short taking into account the operation mode selected via MODE2 (MDS2(2:0)) and the selection of receive CRC ON/OFF (CCR3.RCRC2) as follows: • MDS2(2:0) = 011 (16 bit Address), RCRC2=0 : 4 bytes; RCRC2=1 : 3 or 4 bytes Data Sheet 440 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers • MDS2(2:0) = 010 (8 bit Address), RCRC2=0 : 3 bytes; RCRC2=1 : 2 or 3 bytes Note: Shorter frames are not reported. RDO2 Receive Data Overflow - HDLC Channel 2 A data overflow has occurred during reception of the frame. Additionally, an interrupt can be generated (refer to ISR4.RDO2/IMR4.RDO2). CRC162 RAB2 CRC16 Compare/Check - HDLC Channel 2 0= CRC check failed; received frame contains errors. 1= CRC check o.k.; received frame is error-free. Receive Message Aborted - HDLC Channel 2 This bit is set, if more than 5 contiguous 1-bits are detected. HA12, HA02 High Byte Address Compare - HDLC Channel 2 Significant only if 2-byte address mode is selected. In operating modes which provide high byte address recognition, the FALC® compares the high byte of a 2-byte address with the contents of two individually programmable registers (RAH1, RAH2) and the fixed values FEH and FCH (broadcast address). Depending on the result of this comparison, the following bit combinations are possible: 00 = RAH2 has been recognized 01 = Broadcast address has been recognized 10 = RAH1 has been recognized C/R=0 (bit 1) 11 = RAH1 has been recognized C/R=1 (bit 1) Note: If RAH1, RAH2 contain identical values, a match is indicated by "10" or "11". Data Sheet 441 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers LA2 Low Byte Address Compare - HDLC Channel 2 Significant in HDLC modes only. The low byte address of a 2-byte address field, or the single address byte of a 1-byte address field is compared with two registers. (RAL1, RAL2). 0= RAL2 has been recognized 1= RAL1 has been recognized Signaling Status Register 3 (Read) Value after reset: 00H 7 SIS3 XDOV3 XDOV3 0 XFW3 XREP3 RLI3 CEC3 (9A) Transmit Data Overflow - HDLC Channel 3 More than 32 bytes have been written to the XFIFO3. This bit is reset – by a transmitter reset command XRES or – when all bytes in the accessible half of the XFIFO3 have been moved in the inaccessible half. XFW3 Transmit FIFO Write Enable - HDLC Channel 3 Data can be written to the XFIFO3. XREP3 Transmission Repeat - HDLC Channel 3 Status indication of CMDR3.XREP3. RLI3 Receive Line Inactive - HDLC Channel 3 Neither flags as interframe time fill nor frames are received via the signaling time slot. CEC3 Command Executing - HDLC Channel 3 0 = No command is currently executed, the CMDR4 register can be written to. 1 = A command (written previously to CMDR4) is currently executed, no further command can be temporarily written in CMDR4 register. Note: CEC3 will be active at most 2.5 periods of the current system data rate. Data Sheet 442 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive Signaling Status Register 3 (Read) Value after reset: 00H 7 RSIS3 VFR3 0 RDO3 CRC163 RAB3 HA13 HA03 LA3 (9B) RSIS3 relates to the last received HDLC channel 3 frame; it is copied into RFIFO3 when end-of-frame is recognized (last byte of each stored frame). VFR3 Valid Frame - HDLC Channel 3 Determines whether a valid frame has been received. 1= Valid 0= Invalid An invalid frame is either – a frame which is not an integer number of 8 bits (n×8 bits) in length (e.g. 25 bits), or – a frame which is too short taking into account the operation mode selected via MODE3 (MDS3(2:0)) and the selection of receive CRC ON/OFF (CCR4.RCRC3) as follows: • MDS3(2:0)=011 (16 bit Address), RCRC3=0: 4 bytes; RCRC3=1: 3 or 4 bytes • MDS3(2:0)=010 (8 bit Address), RCRC3=0: 3 bytes; RCRC3=1: 2 or 3 bytes Note: Shorter frames are not reported. RDO3 Receive Data Overflow - HDLC Channel 3 A data overflow has occurred during reception of the frame. Additionally, an interrupt can be generated (refer to ISR5.RDO3/IMR5.RDO3). CRC163 RAB3 CRC16 Compare/Check - HDLC Channel 3 0= CRC check failed; received frame contains errors. 1= CRC check o.k.; received frame is error-free. Receive Message Aborted - HDLC Channel 3 This bit is set, if more than 5 contiguous 1-bits are detected. Data Sheet 443 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers HA13, HA03 High Byte Address Compare - HDLC Channel 3 Significant only if 2-byte address mode is selected. In operating modes which provide high byte address recognition, the FALC® compares the high byte of a 2-byte address with the contents of two individually programmable registers (RAH1, RAH2) and the fixed values FEH and FCH (broadcast address). Depending on the result of this comparison, the following bit combinations are possible: 00 = RAH2 has been recognized 01 = Broadcast address has been recognized 10 = RAH1 has been recognized C/R=0 (bit 1) 11 = RAH1 has been recognized C/R=1 (bit 1) Note:If RAH1, RAH2 contain identical values, a match is indicated by "10" or "11". LA3 Low Byte Address Compare - HDLC Channel 3 Significant in HDLC modes only. The low byte address of a 2-byte address field, or the single address byte of a 1-byte address field is compared with two registers. (RAL1, RAL2). 0= 1= Data Sheet RAL2 has been recognized RAL1 has been recognized 444 2002-08-27 FALC56 V1.2 PEB 2256 T1/J1 Registers Receive FIFO 2 (Read) Value after reset: 00H 7 0 RFIFO2 RF7 RF0 (9C) RFIFO2 RF15 RF8 (9D) RF(15:0) Receive FIFO - HDLC Channel 2 The function is equivalent to RFIFO of HDLC channel 1. Receive FIFO 3 (Read) Value after reset: 00H 7 0 RFIFO3 RF7 RF0 (9E) RFIFO3 RF15 RF8 (9F) RF(15:0) Receive FIFO - HDLC Channel 3 The function is equivalent to RFIFO of HDLC channel 1. Identification Register (Read) Value after reset: xxxxxx11 7 WID x 0 x x x x x 1 1 (EC) Additional version identification register. Data Sheet 445 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11 Electrical Characteristics 11.1 Absolute Maximum Ratings Parameter Symbol Ambient temperature under bias – 40 to 85 °C – 65 to 125 °C – 0.4 to 6.5 V – 0.4 to 6.5 V – 0.4 to 6.5 V Voltage on any pin with respect to ground TA Tstg VDD VDDR VDDX VS – 0.4 to 6.5 V ESD robustness1) HBM: 1.5 kΩ, 100 pF VESD,HBM 2000 V Storage temperature IC supply voltage (digital) IC supply voltage receive (analog) IC supply voltage transmit (analog) 1) Limit Values Unit According to JEDEC standard JESD22-A114. Note: Stresses above those listed here may cause permanent damage to the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. 11.2 Operating Range Parameter Ambient temperature Supply voltages Analog input voltages Digital input voltages Ground 1) Symbol TA VDD VDDR VDDX VIA VID VSS VSSR VSSX Limit Values Unit Test Condition min. max. -40 85 °C 3.13 3.46 V 3.3 V ± 5% 1) 0 VDDR+0.3 V 0 5.25 V 0 0 V VDD = 5.0 V± 5% Voltage ripple on analog supply less than 50 mV Note: In the operating range, the functions given in the circuit description are fulfilled. VDD, VDDR and VDDX have to be connected to the same voltage level, VSS, VSSR and VSSX have to be connected to ground level. Data Sheet 446 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.3 DC Characteristics Parameter Input low voltage Input high voltage Output low voltage Output high voltage Average power supply current (analog line interface mode) Symbol VIL VIH VOL VOH IDDE1 Limit Values Unit Notes min. max. – 0.4 0.8 V 1) 2.0 5.25 V 1) VSS 0.45 V 2.4 VDD V IOL = + 2 mA 2) IOH = - 2 mA 2) 145 mA E1 application3) LIM1.DRS=0 mA T1 application4) LIM1.DRS=0 mA LIM1.DRS=15) µA VIN =VDD6); typ. 80 IDDT1 145 typ. 80 Average power supply current (digital line interface mode) IDD Input leakage current IIL11 90 typ. 50 1 all except RDO Input leakage current IIL12 1 µA VIN =VSS 6); all except RDO Input pullup current Output leakage current IIP IOZ1 2 15 µA 1 µA VIN =VSS VOUT = tristate1) VSS < Vmeas < VDD measured against VDD and VSS; all except XL1/2 2.5 µA XL1/2 = VDDX; XPM2.XLT = 1 2.5 µA XL1/2 = VSSX; XPM2.XLT = 1 3 Ω applies to XL1and XL27) Transmitter output current IX 105 mA XL1, XL2 Differential peak voltage of VX a mark (between XL1 and XL2) 2.15 V Transmitter leakage current Transmitter output impedance Data Sheet ITL RX 447 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Parameter Symbol Limit Values min. Receiver differential peak voltage of a mark (between RL1 and RL2) VR Unit Notes max. VDDR+0.3 V Receiver input impedance ZR 50 (typical value) RL1, RL2 kΩ 8) Receiver sensitivity SRSH 0 10 dB RL1, RL2 LIM0.EQON=0 (short-haul) Receiver sensitivity SRLH 0 43 dB RL1, RL2 LIM0.EQON=1 (E1, long-haul) 0 36 Receiver input threshold VRTH 45 RL1, RL2 LIM0.EQON=1 (T1/J1, long-haul) % LIM2.SLT(1:0)=11 7) 50 55 LIM2.SLT(1:0)=10 default setting7) LIM2.SLT(1:0)=00 7) 67 LIM2.SLT(1:0)=01 7) Data Sheet 448 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Parameter Symbol Limit Values min. Loss-Of-signal (LOS) detection limit in shorthaul mode VLOSSH Unit Notes max. 0.91 0.74 0.59 0.42 0.32 0.21 0.16 0.10 (typical values) V RIL(2:0)=000 RIL(2:0)=001 RIL(2:0)=010 RIL(2:0)=011 RIL(2:0)=100 RIL(2:0)=101 RIL(2:0)=110 RIL(2:0)=111 7) 8) LOS detection limit in long-haul mode VLOSLH 1.70 0.84 0.84 0.45 0.45 0.20 0.10 not defined (typical values) V RIL(2:0)=000 RIL(2:0)=001 RIL(2:0)=010 RIL(2:0)=011 RIL(2:0)=100 RIL(2:0)=101 RIL(2:0)=110 RIL(2:0)=111 7) 8) 1) Applies to all input pins except analog pins RLx 2) Applies to all output pins except pins XLx 3) Wiring conditions and external circuit configuration according to Figure 107 and Table 90 on page 476. 4) Wiring conditions and external circuit configuration according to Figure 107 and Table 91 on page 477. 5) System interface at 16 MHz; all-ones data. 6) Pin leakage is measured in a test mode with all internal pullups disabled. RDO pins are not tristatable, no leakage is measured. 7) Parameter not tested in production 8) Differential input voltage between pins RL1 and RL2; depends on programming of register LIM1.RIL(2:0) Note: Typical characteristics specify mean values expected over the production spread. If not specified otherwise, typical characteristics apply at TA=25 °C and 3.3V supply voltage. Data Sheet 449 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4 AC Characteristics 11.4.1 Master Clock Timing 1 2 3 MCLK F0007 Figure 81 MCLK Timing Table 70 MCLK Timing Parameters No. Parameter Limit Values min. 1 Clock period of MCLK 488 ns E1, fixed mode 648 ns T1/J1, fixed mode typ. max. 980.4 ns % High phase of MCLK 40 3 Low phase of MCLK 40 if clock divider programming fits without rounding 2) if clock divider programming requires rounding E1/T1/J1, flexible mode % 1) 32 1) Data Sheet Condition 50 2 Clock accuracy Unit 450 28 2) ppm 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.2 JTAG Boundary Scan Interface 1 TRS 2 3 4 TCK 5 6 7 8 TMS, TDI TDATI 9 TDO, TDATO F0120 Figure 82 JTAG Boundary Scan Timing Table 71 JTAG Boundary Scan Timing Parameter Values No. Parameter Limit Values min. Unit max. 1 TRS reset active low time 200 ns 2 TCK period 250 ns 3 TCK high time 80 ns 4 TCK low time 80 ns 5 TMS, TDI setup time 40 ns 6 TMS, TDI hold time 40 ns 7 TDATI setup time 40 ns 8 TDATI hold time 40 ns 9 TDO, TDATO output delay 100 ns Identification Register: 32 bit; Version: 3H; Part Number: 59H, Manufacturer: 083H Data Sheet 451 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.3 Reset 1 RES F0008 Figure 83 Reset Timing Table 72 Reset Timing Parameter Values No. Parameter Limit Values min. 1 1) 101) RES pulse width low Unit max. µs while MCLK is running Data Sheet 452 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.4 Microprocessor Interface 11.4.4.1 Intel Bus Interface Mode Ax BHE CS 3 3A 1 2 RD WR Figure 84 ITT10975 Intel Non-Multiplexed Address Timing Ax BHE 5 4 6 ALE 7 7A 1 CS 3 3A RD WR Figure 85 Data Sheet ITT10977 Intel Multiplexed Address Timing 453 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics CS 8 9 RD 9 8 WR 11 10 Dx F0121 Figure 86 Intel Read Cycle Timing CS 9 14 8 13 WR 129 RD 15 16 D7... D0 (D15... D8) ITT06471 Figure 87 Data Sheet Intel Write Cycle Timing 454 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Table 73 No. Intel Bus Interface Timing Parameter Values Parameter Limit Values min. Unit max. 1 Address, BHE setup time 5 ns 2 Address, BHE hold time 0 ns 3 CS setup time 0 ns 3A CS hold time 0 ns 4 Address, BHE stable before ALE inactive 20 ns 5 Address, BHE hold after ALE inactive 10 ns 6 ALE pulse width 30 ns 7 ALE setup time before command active 0 ns 7A ALE to command inactive delay 30 ns 8 RD, WR pulse width 80 ns 9 RD, WR control interval 70 ns 10 Data valid after RD active 11 Data hold after RD inactive 10 15 Data stable before WR inactive 30 ns 16 Data hold after WR inactive 10 ns Data Sheet 455 75 ns 30 ns 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.4.2 Motorola Bus Interface Mode Ax, BLE 17 18 CS 19 RW 19A 20 21 22 23 DS 24 25 Dx Figure 88 F0122 Motorola Read Cycle Timing Ax BLE 17 18 CS 19 19A RW 20 21 22A 23 DS 26 27 D7... D0 (D15 ... D8) ITT10974 Figure 89 Motorola Write Cycle Timing Data Sheet 456 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Table 74 No. Motorola Bus Interface Timing Parameter Values Parameter Limit Values min. Unit max. 17 Address, BLE setup time before DS active 15 ns 18 Address, BLE hold after DS inactive 0 ns 19 CS active before DS active 0 ns 19A CS hold after DS inactive 0 ns 20 RW stable before DS active 10 ns 21 RW hold after DS inactive 0 ns 22 DS pulse width (read access) 80 ns 22A DS pulse width (write access) 70 ns 23 DS control interval 70 ns 24 Data valid after DS active (read access) 25 Data hold after DS inactive (read access) 10 26 Data stable before DS active (write access) 30 ns 27 Data hold after DS inactive (write access) 10 ns Data Sheet 457 75 ns 30 ns 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.5 Line Interface 30 32 31 RCLKI 33 34 ROID 30A RDIP RDIN F0264_1 Figure 90 Digital Line Interface Receive Timing 35 37 36 XCLK 38 38 XOID1) XOID XDOP XDON XFM 1) Figure 91 Data Sheet CMI coding F0264_2 Digital Line Interface Transmit Timing 458 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Table 75 No. Digital Line Interface Parameter Values Parameter Limit Values E1 min. typ. Unit T1 max. min. 488 typ. max. 30 RCLKI clock period 30A RDIP/RDIN period high 122 31 RCLKI clock period low 180 240 ns 32 RCLKI clock period high 180 240 ns 33 ROID setup 50 50 ns 34 ROID hold 50 50 ns 35 XCLK clock period 36 XCLK clock period low XCLK clock period low1) 190 150 230 200 ns 37 XCLK clock period high XCLK clock period high1) 190 150 230 200 ns 38 XOID delay2) XDOP/XDON delay3) 244 648 366 162 488 324 ns 486 648 60 ns ns 60 ns 1) depends on input RCLKI in optical interface and remote loop without transmit jitter attenuator enabled (LIM1.JATT/RL=01) 2) NRZ coding 3) HDB3/AMI/B8ZS coding Data Sheet 459 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.6 System Interface 1 2 3 RCLK (output) 4 RFSP data valid Note: active edge can be programmed to be positive or negative (only negative edge timing shown here); valid only, if RCLK id derived from DPLL (not, if RCLK jitter is attenuated) F0009 Figure 92 RCLK, RFSP Output Timing Table 76 RCLK, RFSP Timing Parameter Values No. Parameter Limit Values min. 1 typ. Unit max. RCLK period E1 (2.048 MHz) 488 ns RCLK period E1 (2.048 MHz × 4) 122 ns RCLK period T1/J1 (1.544 MHz) 648 ns RCLK period T1/J1 (1.544 MHz × 4) 162 ns 2 RCLK pulse high 40 60 % 3 RCLK pulse low 40 60 % 4 RFSP delay 80 ns Data Sheet 460 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 1 2 3 SCLKR SCLKX (input) F0010 Figure 93 SCLKR/SCLKX Input Timing Table 77 SCLKR/SCLKX Timing Parameter Values No. Parameter Limit Values min. typ. Unit max. 1 SCLKR/SCLKX period at 16.384 MHz 61 ns 1 SCLKR/SCLKX period at 8.192 MHz 122 ns 1 SCLKR/SCLKX period at 4.096 MHz 244 ns 1 SCLKR/SCLKX period at 2.048 MHz 488 ns 1 SCLKR/SCLKX period at 12.352 MHz 81 ns 1 SCLKR/SCLKX period at 6.176 MHz 162 ns 1 SCLKR/SCLKX period at 3.088 MHz 324 ns 1 SCLKR/SCLKX period at 1.544 MHz 648 ns 2 SCLKR/SCLKX pulse high 40 % 3 SCLKR/SCLKX pulse low 40 % Data Sheet 461 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics positive edge timing 1) negative edge timing 1) SCLKR 1 RDO RSIG RSIGM DLR RFM RMFB FREEZE 2 data valid 1 2 data valid 1) active edge can be programmed to be positive or negative F0011 Figure 94 System Interface Marker Timing (Receive) Table 78 System Interface Marker Timing Parameter Values No. Parameter Limit Values min. typ. Unit max. SCLKR input mode 1 RDO delay 0 35 ns 2 RSIGM, RMFB, DLR, RFM, FREEZE, RSIG marker delay 0 45 ns SCLKR output mode 1A RDO delay -55 -20 ns 2A RSIGM, RMFB, DLR, RFM, FREEZE, RSIG marker delay -55 -20 ns SCLKR can be input or output. Data Sheet 462 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 1 active edge SCLKR SCLKX 2 3 SYPR SYPX inactive active low 5 6 XMFS 4 inactive 7 active low F0012 Figure 95 SYPR, SYPX Timing Table 79 SYPR/SYPX Timing Parameter Values No. Parameter Limit Values min. typ.1) Unit max. SCLKR input mode 1 SCLKR period (t1) 2 SYPR/SYPX inactive setup time 3 61 648 ns 1 x t1 ns SYPR/SYPX setup time 5 ns 4 SYPR/SYPX hold time 15 ns 5 XMFS inactive setup time 1 x t1 ns 6 XMFS setup time 5 ns 7 XMFS hold time 15 ns SCLKR output mode 1A SCLKR period (t1) 2A SYPR/SYPX inactive setup time 3A SYPR/SYPX setup time Data Sheet 61 463 648 ns 1 x t1 ns 10 ns 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Table 79 No. SYPR/SYPX Timing Parameter Values (cont’d) Parameter Limit Values min. 4A SYPR/SYPX hold time 5A XMFS inactive setup time 6A 7A 1) typ.1) Unit max. 0 ns 1 x t1 ns XMFS setup time 10 ns XMFS hold time 0 ns typical value, not tested in production Data Sheet 464 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics active edge1) SCLKR SCLKX 1 XMFB DLX XSIGM 1) active edge can be programmed to be positive or negative F0013 Figure 96 System Interface Marker Timing (Transmit) Table 80 System Interface Marker Timing Parameter Values1) No. Parameter Limit Values min. typ. Unit max. SCLKR input mode 1 XMFB, DLX, XSIGM delay 100 ns -20 ns SCLKR output mode 1A 1) XMFB, DLX, XSIGM delay Parameters based on SCLKR when CMR2.IXSC = 1 and on SCLKX when CMR2.IXSC = 0 (input mode only) Data Sheet 465 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics active edge1) SCLKR SCLKX 1 2 3 4 XDI XSIG 1) active edge can be programmed to be positive or negative F0014 Figure 97 XDI, XSIG Timing Table 81 XDI, XSIG Timing Parameter Values1) No. Parameter Limit Values min. typ. Unit max. SCLKR input mode 1 XDI setup time 5 ns 2 XDI hold time 15 ns 3 XSIG setup time 5 ns 4 XSIG hold time 15 ns SCLKR output mode 1A XDI setup time 10 ns 2A XDI hold time 20 ns 3A XSIG setup time 10 ns 4A XSIG hold time 20 ns 1) Parameters based on SCLKR when CMR2.IXSC = 1 and on SCLKX when CMR2.IXSC = 0 (input mode only) Data Sheet 466 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 1 2 3 TCLK F0016 Figure 98 TCLK Input Timing Table 82 TCLK Timing Parameter Values No. Parameter Limit Values min. 1 typ. Unit max. TCLK period E1 (2.048 MHz) 488 ns TCLK period E1 (2.048 MHz × 4) 122 ns TCLK period T1/J1 (1.544 MHz) 648 ns TCLK period T1/J1 (1.544 MHz × 4) 162 ns 2 TCLK high 40 % 3 TCLK low 40 % Data Sheet 467 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics MCLK 1 XCLK F0123 Figure 99 XCLK Timing Table 83 XCLK Timing Parameter values No. Parameter Limit Values E1 min. 1 1) typ. 1) XCLK delay Unit T1 max. 100 min. typ. max. 100 ns valid in transmit buffer bypass mode only Data Sheet 468 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 1 2 3 SEC (input) 4 5 6 SEC1) (output) 1) clock running continuously F0018 Figure 100 SEC Timing Table 84 SEC Timing Parameter Values No. Parameter1) Limit Values min. typ. max. 1 SEC input period E1/T1/J1 2 SEC input high E1 976 ns SEC input high T1/J1 1296 ns SEC input low E1 976 ns SEC input low T1/J1 1296 ns 3 1 Unit 4 SEC output period E1/T1/J1 5 SEC high output E1 976 ns SEC high output T1/J1 1296 ns 1) 1 s s typical value, not tested in production Data Sheet 469 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 1 2 FSC 3 RCLK 4 SCLKR (output) F0124 Figure 101 FSC Timing Table 85 FSC Timing Parameter Values No. Parameter Limit Values min. typ. Unit max. 1 FSC1) period 125 µs 2 FSC high/low active time E1 488 ns 2 FSC high/low active time T1/J1 648 ns 3 RCLK to FSC delay 50 80 ns 4 SCLKR to FSC delay 50 80 ns 1) FSC can be programmed to be active high or active low (only the active low timing diagram is shown here) Data Sheet 470 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 1 2 SYNC F0125 Figure 102 SYNC Timing Table 86 SYNC Timing Parameter Values No. Parameter Limit Values min. typ. Unit max. 1 SYNC high time 30 % 2 SYNC low time 30 % Data Sheet 471 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.7 Pulse Templates - Transmitter 11.4.7.1 Pulse Template E1 269 ns (244 + 25) V=100 % 10 % 10 % 20 % 20 % 194 ns (244 - 50) Nominal Pulse 50 % 244 ns 10 % 10 % 20 % 0% 10 % 10 % 219 ns (244 - 25) 488 ns (244 + 244) ITD00573 Figure 103 Data Sheet E1 Pulse Shape at Transmitter Output 472 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.4.7.2 Pulse Template T1 Normalized Amplitude V = 100 % 50 % 0 -50 % 0 250 500 750 1000 ns t ITD00574 Figure 104 T1 Pulse Shape at the Cross Connect Point Table 87 T1 Pulse Template at Cross Connect Point (T1.1021)) Maximum Curve Minimum Curve Time [ns] Level [%]2) Time [ns] Level [%] 0 5 0 -5 250 5 350 -5 325 80 350 50 325 115 400 95 425 115 500 95 500 105 600 90 675 105 650 50 725 -7 650 -45 1100 5 800 -45 1250 5 925 -20 1100 -5 1250 -5 1) requirements of ITU-T G.703 are also fulfilled 2) 100 % value must be in the range of 2.4 V and 3.6 V; tested at 0 ft. and 655 ft. using PIC 22AWG cable characteristics. Data Sheet 473 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.5 Capacitances Parameter Symbol Limit Values min. max. Unit Notes Input capacitance1) CIN 5 10 pF Output capacitance1) COUT 8 15 pF all except XLx Output capacitance1) COUT 8 20 pF XLx 1) Not tested in production. 11.6 Package Characteristics F0051 Figure 105 Thermal Behavior of Package Table 88 Package Characteristic Values Parameter Symbol Limit Values min. typ. Thermal Resistance MQFP Rthjam1) 47 Rthjc2) 9 Thermal Resistance BGA Rthjab1) 29 Junction Temperature Rj 1) Rthja = (Tjunction - Tambient)/Power Not tested in production. 2) Rthjc = (Tjunction - Tcase)/Power Not tested in production. Data Sheet max. K/W single layer PCB, K/W no convection K/W single layer PCB, natural convection 125 474 Unit Notes °C 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.7 Test Configuration 11.7.1 AC Tests Test Levels VTH Device under Test VTL CL Timing Test Points Drive Levels VIH F0067 VIL Figure 106 Input/Output Waveforms for AC Testing Table 89 AC Test Conditions Parameter Symbol Load Capacitance CL 50 pF Input Voltage high VIH 2.4 V all except RLx Input Voltage low VIL 0.4 V all except RLx Test Voltage high VTH 2.0 V all except XLx Test Voltage low VTL 0.8 V all except XLx Data Sheet 475 Test Values Unit Notes 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics 11.7.2 Power Supply Test tt1 : tt2 R1 R1 RL PCM Highway FALC®56 tr1 : tr2 VDD VDDX VDDR R2 F0176 Figure 107 Device Configuration for Power Supply Testing Table 90 Power Supply Test Conditions E1 Parameter Symbol Load Resistance R1 7.5 Ω 1% Termination Resistance R2 120 Ω 1% Line Impedance RL 120 Ω Line Length L < 0.2 m Transformer Ratio Transmit tt1 : tt2 2.4 Transformer Ratio Receive tr1 : tr2 1 PCM Highway Frequency SCLKX SCLKR 2.048 XPM2 00H XPM1 03H XPM0 BDH Ambient Temperature Data Sheet Unit Notes MHz 215-1 Test Signal Pulse Mask Programming Test Values 85 476 PRBS pattern °C 2002-08-27 FALC56 V1.2 PEB 2256 Electrical Characteristics Table 91 Power Supply Test Conditions T1/J1 Parameter Symbol Load Resistance R1 2 Ω 1% Termination Resistance R2 100 Ω 1% Line Impedance RL 100 Ω Line Length L < 0.2 m Transformer Ratio Transmit tt1 : tt2 2.4 Transformer Ratio Receive tr1 : tr2 1 PCM Highway Frequency SCLKX SCLKR 1.544 XPM2 02H XPM1 27H XPM0 9FH Ambient Temperature Data Sheet Unit Notes MHz 215-1 Test Signal Pulse Mask Programming Test Values 85 477 PRBS pattern °C 2002-08-27 FALC56 V1.2 PEB 2256 Package Outlines 12 Package Outlines P-MQFP-80-1 (Plastic Metric Quad Flat Package) Sorts of Packing Package outlines for tubes, trays etc. are contained in our Data Book “Package Information”. SMD = Surface Mounted Device Data Sheet 478 Dimensions in mm 2002-08-27 FALC56 V1.2 PEB 2256 Package Outlines P-LBGA-81-1 (Plastic Ball Grid Array Package) GPA0LB81 Sorts of Packing Package outlines for tubes, trays etc. are contained in our Data Book “Package Information”. SMD = Surface Mounted Device Data Sheet 479 Dimensions in mm 2002-08-27 FALC56 V1.2 PEB 2256 Appendix 13 Appendix 13.1 Protection Circuitry The design in Figure 108 shows an example of how to build up a generic E1/T1/J1 platform. The circuit shown has been successfully checked against ITU-T K.20 and K.21 lightning surge tests (basic level). 1:1 RL1 R3 PTC R2 A VDD RL2 B VSS Fuse 1.25 A A PTC R3 Fuse 1.25 A ® FALC RJ45 1:2.4 XL1 PTC R1 A B VDD XL2 VSS Fuse 1.25 A A PTC R1 Fuse 1.25 A A SMP 100LC-35 (~65 pF) F0262_2 B SMP P3500SC (~60 pF) Figure 108 Data Sheet Protection Circuitry Examples 480 2002-08-27 FALC56 V1.2 PEB 2256 Appendix 13.2 Application Notes Several application notes and technical documentation provide additional information. Online access to supporting information is available on the internet page: http://www.infineon.com/falc On the same page you find as well the • Boundary Scan File for FALC56 Version 1.2 (BSDL File) 13.3 Software Support The following software package is provided together with the FALC56 Reference System EASY2256: • E1 and T1 driver functions supporting different ETSI, AT&T and Telcordia (former: Bellcore) requirements • IBIS model for FALC56 Version 1.2 (according to ANSI/EIA-656) • Flexible Master Clock Calculator • External Line Front End Calculator To make system design easier, two software tools are available. The first is the "Master Clock Frequency Calculator", which calculates the required register settings depending on the external master clock frequency (MCLK). The second is the "External Line Front End Calculator" which provides an easy method to optimize the external components depending on the selected application type. Calculation results are traced an can be stored in a file or printed out for documentation. The tools run under a Win9x/NT environment. Screenshots of both programs are shown in Figure 109 and Figure 110 below. Data Sheet 481 2002-08-27 FALC56 V1.2 PEB 2256 Appendix F0126 Figure 109 Data Sheet Master Clock Frequency Calculator 482 2002-08-27 FALC56 V1.2 PEB 2256 Appendix F0198_2256 Figure 110 Data Sheet External Line Frontend Calculator 483 2002-08-27 FALC56 V1.2 PEB 2256 Glossary 14 Glossary A/D Analog to digital ADC Analog to digital converter AIS Alarm indication signal (blue alarm) AGC Automatic gain control ALOS Analog loss of signal AMI Alternate mark inversion ANSI American National Standards Institute ATM Asynchronous transfer mode AUXP Auxiliary pattern B8ZS Line coding to avoid too long strings of consecutive "0" BER Bit error rate BFA Basic frame alignment BOM Bit orientated message Bellcore Bell Communications Research BPV Bipolar violation BSN Backward sequence number CAS Channel associated signaling CAS-BR Channel associated signaling - bit robbing CAS-CC Channel associated signaling - common channel CCS Common channel signaling CMI coded mark inversion code (also known as 1T2B code) CR Command/Response (special bit in PPR) CRC Cyclic redundancy check CSU Channel service unit CVC Code violation counter DCO Digitally controlled oscillator DL Digital loop DPLL Digitally controlled phase locked loop DS1 Digital signal level 1 EA Extended address (special bit in PPR) Data Sheet 484 2002-08-27 FALC56 V1.2 PEB 2256 Glossary ESD Electrostatic discharge EASY Evaluation system for FALC products ESF Extended superframe (F24) format EQ Equalizer ETSI European Telecommunication Standards Institute FALC® Framing and line interface component FAS Frame alignment sequence FCC US Federal Communication Commission FCS Frame check sequence (used in PPR) FISU Fill in signaling unit FPS Framing pattern sequence FSN Forward sequence number HBM Human body model for ESD classification HDB3 High density bipolar of order 3 HDLC High level data link control IBIS I/O buffer information specification (ANSI/EIA-656) IBL In band loop (=LLB) ISDN Integrated services digital network ITU International Telecommunications Group JATT Jitter attenuator JTAG Joined Test Action Group LAPD Link access procedure on D-channel LBO Line build out LCV Line code violation LIU Line interface unit LFA Loss of frame alignment LL Local loop LLB Line loop back (= IBL) LOS Loss of signal (red alarm) LSB Least significant bit LSSU Link status signaling unit MF Multiframe Data Sheet 485 2002-08-27 FALC56 V1.2 PEB 2256 Glossary MSB Most significant bit MSU Message signaling unit NRZ Non return to zero signal PDV Pulse-density violation PLB Payload loop back PLL Phase locked loop PMQFP Plastic metric quad flat pack (device package) PPR Periodical performance report PRBS Pseudo random binary sequence PTQFP Plastic thin metric quad flat pack (device package) RAI Remote alarm indication (yellow alarm) RL Remote loop SAPI Service access point identifier (special octet in PPR) SF Superframe Sidactor Overvoltage protection device for transmission lines TAP Test access port TEI Terminal endpoint identifier (special octet in PPR) UI Unit interval ZCS Zero code suppression Data Sheet 486 2002-08-27 FALC56 V1.2 PEB 2256 Index CMDR4 270, 390 CMR1 258, 378 CMR2 259, 379 COEC 421 CRC16 74, 100, 135, 161 CRC-Multiframe 83 CVC 299, 417 A Address Bus 29 Address Latch Enable 30 Alarm Simulation 118, 186 Application Notes 481 Applications 22, 24 D B BEC 420 Bit Oriented Message 209 Bit Oriented Messages 137 Bit Robbing 137, 161, 162 Boundary Scan 49, 57, 451, 481 BSN 100, 161 Bus High/Low Enable 31 C CAS 76, 77, 101, 137, 161, 162, 193 CCBx 363 CCR1 221, 338 CCR2 224, 341 CCR3 271, 391 CCR4 273, 393 CCR5 274, 394 CEC 418 CEC1 300 CEC2 302 CEC3 303 Channel Associated Signaling 76, 77, 101 Channel Translation Mode 131 Chip Select 31 Clear Channel 153, 155, 162 Clock and Data Recovery 61, 120 Clock of DCO-R 36 Clock of DCO-X 37 Clock Synchronization 36 Clocking Unit 59, 60 CMDR 217, 334 CMDR2 269, 389 CMDR3 269, 389 Data Sheet D4 139, 143 Data Bus 29 Data Bus Width 30 Data Link Access 211 Data Link Bit Receive 42 Data Link Bit Transmit 47 Data Strobe 30 DEC 262, 382 Defect Insertion 118, 186 DLR 42 DLX 47 Doubleframe Format 80 E EBC 300, 301, 419 Elastic Buffer 70, 97, 129, 157 Error counter 92, 152 ESD 446 ESF 139, 144, 162 ESM 262, 382 F F12 139, 140 F24 139, 144, 162 F4 139, 142 F72 139, 140, 211 FEC 298, 416 FIFO Structure 53 FISU 74, 100, 135, 161 FMR0 228, 345 FMR1 230, 347 FMR2 232, 349 FMR3 245 FMR4 352 487 2002-08-27 FALC56 V1.2 PEB 2256 FMR5 354 Fractional E1 Access 257 Fractional T1/J1 Access 377 Frame Aligner 20 Frame Synchronous Pulse 43 FRS0 291, 411 FRS1 294, 413 FRS2 415 FSN 100, 161 G GCM1 277, 397 GCM2 277, 397 GCM3 278, 398 GCM4 278, 399 GCM5 279, 400 GCM6 279, 400 GCR 261, 381 GIS 55, 321, 437 GPC1 267, 387 H HDLC 192, 201 I IBIS Model 481 ICBx 246, 364 IDLE 243, 362 IEEE 1149.1 57 IERR 227, 345 IMRx 227, 344 In-Band Loop 92, 153 Initialization in E1 Mode 188 Initialization in T1/J1 Mode 194 INT 55 Interface Mode 31 Interrupt 31 Interrupt Interface 55 IPC 56, 221, 338 IS 55 ISR0 310, 428 ISR1 312, 430 ISR2 314, 431 Data Sheet ISR3 316, 433 ISR4 317, 434 ISR5 319, 436 J J1-Features 187 Jitter 66, 96, 125, 155 JTAG 49 L LCR1 251, 370 LCR2 253, 372 LCR3 253, 372 LIM0 247, 364 LIM1 248, 366 LIM2 250, 369 Line Build-Out 159 Line Coding 62, 121 Line Interface 19, 32, 34, 458 Line Monitoring 63, 123 Local Loop 116, 184 LOOP 233, 351 LOS 449 Loss of Signal 65, 124 LSSU 74, 135 M Master Clock 36, 59 Microprocessor Interface 21, 52, 453 MODE 219, 336 MODE2 275, 395 MODE3 276, 396 MSU 74, 135 Multifunction Port 40, 44 O One-Second Timer 37, 92, 152 P Payload Loop Back 117, 183 P-BGA-81 479 PC1...4 264, 384 PC5 266, 386 488 2002-08-27 FALC56 V1.2 PEB 2256 PC6 268, 388 PCD 249, 367 PCR 250, 368 Performance Monitoring 85, 150 Periodical Performance Report 162 Power Supply 48 PPR 162, 389, 395 Protection 480 Protection Switching 124 Pseudo-Random Bit Sequence 114, 182 P-TQFP-144-8 478 Pulse Density 153 Pulse Shaper 98, 159 Pulse Template 472, 473 R RAH1 220, 337 RAH2 220, 337 RAL1 220, 337 RAL2 220, 337 RBC2 323, 439 RBC3 323, 439 RBCH 310, 427 RBCL 310, 427 RBD 289, 409 RC0 238, 357 RC1 239, 359 RDL1 422 RDL2 422 RDL3 423 Read Enable 30 Read/Write Enable 30 Receive Clock 38 Receive Clock Input 33 Receive Data Input 32, 33 Receive Data Out 39 Receive Equalization Network 61, 120 Receive Frame Marker 41 Receive Line Attenuation Indication 61, 120 Receive Line Interface 60, 119 Receive Multiframe Begin 41 Receive Optical Interface 32 Data Sheet Receive Signaling Data 42 Receive Signaling Marker 42 Register Addresses 213, 286, 330, 407 Remote Loop 114, 182 RES 48, 290, 410 Reset 48, 188, 194, 452 RFIFO 289, 409 RFIFO2 329, 445 RFIFO3 329, 445 RFM 41 RFSP 43 RMFB 41 RS1...12 438 RS1...16 322 RSA6S 305 RSAx 304 RSIG 42 RSIGM 42 RSIS 308, 425 RSIS2 325, 440 RSIS3 327, 443 RSP 296 RSP1 306, 423 RSP2 306, 423 RSW 295 RTR1...4 225 RTRx 342 S Sa bit Access 208 SAPI 395 SCLKX 43 SF 143 SIC1 254, 373 SIC2 255, 374 SIC3 256, 376 Signaling Controller 21, 73, 99, 134, 160 Single Channel Loop Back 117, 185 SIS 307, 424 SIS2 323, 439 SIS3 326, 442 SLC96 139, 146 Software 481 489 2002-08-27 FALC56 V1.2 PEB 2256 SS7 74, 100, 135, 161, 219, 336 SU 74, 100, 135, 161 Supply voltage 446 Synchronous Pulse Receive 40 Synchronous Pulse Transmit 45 SYPX 45 System Clock Receive 39 System Clock Transmit 43 System Interface 39, 43, 102, 165, 460 T TCLK 46 Test Access Port 57 Test Clock 49 Test Data Input 49 Test Data Output 49 Test Mode Select 49 Test Reset 49 Time-Slot Assigner 113, 180 TPC0 285, 406 Transmit Clock 46, 47 Transmit Data In 43 Transmit Data Output 34, 35 Transmit Frame Marker 35 Transmit Line Interface 95, 154 Transmit Line Monitor 98, 160 Transmit Line Tristate 47 Transmit Multiframe Begin 46 Transmit Multiframe Synchronization 45 Transmit Optical Interface 34 Transmit Signaling Data 45 Transmit Signaling Marker 46 Transparent Mode 204 TSBS1 282, 403 TSBS2 283, 404 TSBS3 283, 404 TSEO 281, 402 TSS2 284, 405 TSS3 284, 405 TSWM 242 TTR1...4 226 TTRx 343 Data Sheet U Unused Pins 49 V VIS 56 VSTR 290, 410 W WID 329, 445 Write Enable 30 X XC0 236, 355 XC1 237, 356 XCLK 47 XDI 43 XDLx 362 XFIFO 217, 334 XFIFO2 281, 402 XFIFO3 281, 402 XLT 47 XMFB 46 XMFS 45 XPMx 241, 361 XS1...12 383 XS1...16 263 XSAx 244 XSIG 45 XSIGM 46 XSP 235 XSW 234 XTS16RA 221 490 2002-08-27