INFINEON PEB2256E

D at a S hee t, DS 3, A ug . 2 00 2
FALC56
E1/T1/J1 Framer and Line
Interface Component for Longand Short-Haul Applications
PEB 2256 HT Version 1.2
PEB 2256 E Version 1.2
W i r ed
Communications
N e v e r
s t o p
t h i n k i n g .
Data Sheet
Revision History:
2002-08-27
Previous Version:
DS 2
Page
Subjects (major changes since last revision)
479
P-LBGA-81-1 Package Outline
DS 3
For questions on technology, delivery and prices please contact the Infineon
Technologies Offices in Germany or the Infineon Technologies Companies and
Representatives worldwide: see our webpage at http://www.infineon.com
ABM®, ABM®, ACE®, AOP®, ARCOFI®, ASM®, ASP®, DigiTape®, DuSLIC®, EPIC®,
ELIC®, FALC®, GEMINAX®, IDEC®, INCA®, IOM®, IPAT®-2, ISAC®, ITAC®, IWE®,
IWORX®, MUSAC®, MuSLIC®, OCTAT®, OptiPort®, POTSWIRE®, QUAT®,
QuadFALC®, SCOUT®, SICOFI®, SIDEC®, SLICOFI®, SMINT®, SOCRATES®,
VINETIC®, 10BaseV®, 10BaseVX® are registered trademarks of Infineon
Technologies AG.
10BaseS™, EasyPort™ are trademarks of Infineon Technologies AG.
Edition 2002-08-27
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
D-81541 München, Germany
© Infineon Technologies AG 2002.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as warranted
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office in Germany or our Infineon Technologies Representatives worldwide.
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.
FALC56 V1.2
PEB 2256
Table of Contents
Page
1
1.1
1.2
1.3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logic Symbol
............................................
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
19
23
24
2
2.1
2.2
2.3
Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram P-MQFP-80-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram P-LBGA-81-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Definitions and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
26
27
29
3
3.1
3.2
3.3
3.3.1
3.3.1.1
3.3.1.2
3.3.1.3
3.3.2
3.3.3
Functional Description E1/T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functional Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Microprocessor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mixed Byte/Word Access to the FIFOs . . . . . . . . . . . . . . . . . . . . . . .
FIFO Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Boundary Scan Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Master Clocking Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50
50
51
52
52
52
53
55
57
59
4
Functional Description E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1
Receive Path in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.1
Receive Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.2
Receive Short and Long-Haul Interface . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.3
Receive Equalization Network (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.4
Receive Line Attenuation Indication (E1) . . . . . . . . . . . . . . . . . . . . . . . .
4.1.5
Receive Clock and Data Recovery (E1) . . . . . . . . . . . . . . . . . . . . . . . .
4.1.6
Receive Line Coding (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.7
Receive Line Monitoring Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.8
Loss-of-Signal Detection (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.9
Receive Jitter Attenuator (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.10
Jitter Tolerance (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.11
Output Jitter (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.12
Framer/Synchronizer (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.13
Receive Elastic Buffer (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.14
Receive Signaling Controller (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.14.1
HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.14.2
Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.14.3
Sa-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.14.4
Channel Associated Signaling CAS (E1, serial mode) . . . . . . . . . . .
4.1.14.5
Channel Associated Signaling CAS (E1, µP access mode) . . . . . . .
4.2
Framer Operating Modes (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
60
60
60
60
61
61
61
62
63
65
66
69
69
70
70
73
73
74
76
76
77
79
79
Data Sheet
3
2002-08-27
FALC56 V1.2
PEB 2256
Table of Contents
4.2.2
4.2.2.1
4.2.2.2
4.2.2.3
4.2.2.4
4.2.3
4.2.3.1
4.2.3.2
4.2.3.3
4.2.3.4
4.2.3.5
4.2.3.6
4.2.3.7
4.2.3.8
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.3.6
4.3.7
4.4
4.4.1
4.4.2
4.4.3
4.4.4
4.4.5
4.4.6
4.4.7
4.4.7.1
4.4.7.2
4.4.7.3
4.4.7.4
4.4.7.5
4.5
4.5.1
4.5.1.1
4.5.2
4.5.2.1
4.5.3
4.6
Page
Doubleframe Format (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Transmit Transparent Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
A-Bit Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Sa-Bit Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
CRC-Multiframe (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Automatic Force Resynchronization (E1) . . . . . . . . . . . . . . . . . . . . . 85
Floating Multiframe Alignment Window (E1) . . . . . . . . . . . . . . . . . . . 85
CRC4 Performance Monitoring (E1) . . . . . . . . . . . . . . . . . . . . . . . . . 85
Modified CRC4 Multiframe Alignment Algorithm (E1) . . . . . . . . . . . . 85
A-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Sa-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
E-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Additional Receive Framer Functions (E1) . . . . . . . . . . . . . . . . . . . . . . . . 90
Error Performance Monitoring and Alarm Handling . . . . . . . . . . . . . . . . 90
Auto Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Errored Second . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
One-Second Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
In-Band Loop Generation and Detection . . . . . . . . . . . . . . . . . . . . . . . . 92
Time Slot 0 Transparent Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Transmit Path in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Transmitter (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Transmit Line Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Transmit Jitter Attenuator (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Transmit Elastic Buffer (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Programmable Pulse Shaper (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Transmit Line Monitor (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Transmit Signaling Controller (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Sa-Bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Channel Associated Signaling CAS (E1, serial mode) . . . . . . . . . . 101
Channel Associated Signaling CAS (E1, µP access mode) . . . . . . 101
System Interface in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Receive System Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Receive Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Transmit System Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Transmit Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Time Slot Assigner (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Test Functions (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Data Sheet
4
2002-08-27
FALC56 V1.2
PEB 2256
Table of Contents
4.6.1
4.6.2
4.6.3
4.6.4
4.6.5
4.6.6
4.6.7
Page
Pseudo-Random Binary Sequence Generation and Monitor . . . . . . . .
Remote Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Payload Loop-Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Channel Loop-Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm Simulation (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Bit Defect Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
114
114
115
116
117
118
118
5
Functional Description T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1
Receive Path in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.1
Receive Line Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.2
Receive Short and Long-Haul Interface (T1/J1) . . . . . . . . . . . . . . . . .
5.1.3
Receive Equalization Network (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.4
Receive Line Attenuation Indication (T1/J1) . . . . . . . . . . . . . . . . . . . .
5.1.5
Receive Clock and Data Recovery (T1/J1) . . . . . . . . . . . . . . . . . . . . .
5.1.6
Receive Line Coding (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.7
Receive Line Monitoring Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.8
Loss-of-Signal Detection (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.9
Receive Jitter Attenuator (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.10
Jitter Tolerance (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.11
Output Jitter (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.12
Framer/Synchronizer (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.13
Receive Elastic Buffer (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.14
Receive Signaling Controller (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.14.1
HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.14.2
Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.14.3
CAS Bit-Robbing (T1/J1, serial mode) . . . . . . . . . . . . . . . . . . . . . . .
5.1.14.4
CAS Bit-Robbing (T1/J1, µP access mode) . . . . . . . . . . . . . . . . . . .
5.1.14.5
Bit Oriented Messages in ESF-DL Channel (T1/J1) . . . . . . . . . . . .
5.1.14.6
4 kbit/s Data Link Access in F72 Format (T1/J1) . . . . . . . . . . . . . . .
5.2
Framer Operating Modes (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2
General Aspects of Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.3
Addition for F12 and F72 Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.4
4-Frame Multiframe (F4 Format, T1/J1) . . . . . . . . . . . . . . . . . . . . . . .
5.2.4.1
Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.5
12-Frame Multiframe (D4 or SF Format, T1/J1) . . . . . . . . . . . . . . . . .
5.2.5.1
Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.6
Extended Superframe (F24 or ESF Format, T1/J1) . . . . . . . . . . . . . . .
5.2.6.1
Synchronization Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.6.2
Remote Alarm (yellow alarm) Generation/Detection . . . . . . . . . . . .
5.2.6.3
CRC6 Generation and Checking (T1/J1) . . . . . . . . . . . . . . . . . . . . .
5.2.7
72-Frame Multiframe (SLC96 Format, T1/J1) . . . . . . . . . . . . . . . . . . .
119
119
119
119
120
120
120
121
123
124
125
128
129
129
129
134
134
135
137
137
137
138
139
139
139
140
142
142
143
143
144
145
146
146
146
Data Sheet
5
2002-08-27
FALC56 V1.2
PEB 2256
Table of Contents
Page
5.2.7.1
5.2.8
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.3.5
5.3.6
5.3.7
5.3.8
5.3.9
5.4
5.4.1
5.4.2
5.4.3
5.4.4
5.4.5
5.4.6
5.4.7
5.4.7.1
5.4.7.2
5.4.7.3
5.4.7.4
5.4.7.5
5.4.7.6
5.5
5.5.1
5.5.1.1
5.5.2
5.5.2.1
5.5.3
5.6
5.6.1
5.6.2
5.6.3
5.6.4
5.6.5
5.6.6
5.6.7
5.7
Synchronization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of Frame Conditions (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . .
Additional Receive Framer Functions (T1/J1) . . . . . . . . . . . . . . . . . . . . .
Error Performance Monitoring and Alarm Handling . . . . . . . . . . . . . . .
Auto Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Errored Second . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
One-Second Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clear Channel Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
In-Band Loop Generation and Detection . . . . . . . . . . . . . . . . . . . . . . .
Transparent Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pulse-Density Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Path in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmitter (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Line Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Jitter Attenuator (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Elastic Buffer (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programmable Pulse Shaper and Line Build-Out (T1/J1) . . . . . . . . . .
Transmit Line Monitor (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Signaling Controller (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC or LAPD access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Support of Signaling System #7 . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAS Bit-Robbing (T1/J1, serial mode) . . . . . . . . . . . . . . . . . . . . . . .
CAS Bit-Robbing (T1/J1, µP access mode) . . . . . . . . . . . . . . . . . . .
Data Link Access in ESF/F24 and F72 Format (T1/J1) . . . . . . . . . .
Periodical Performance Report in ESF Format (T1/J1) . . . . . . . . . .
System Interface in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive System Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit System Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Offset Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Time Slot Assigner (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Functions (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pseudo-Random Binary Sequence Generation and Monitor . . . . . . . .
Remote Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Payload Loop-Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Channel Loop-Back (loop-back of time slots) . . . . . . . . . . . . . .
Alarm Simulation (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Bit Defect Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
J1-Feature Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
Operational Description E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Data Sheet
6
147
149
150
150
151
152
152
152
153
153
153
153
154
154
154
155
157
159
160
160
160
161
161
162
162
162
165
167
168
172
178
180
182
182
182
183
184
185
186
186
187
2002-08-27
FALC56 V1.2
PEB 2256
Table of Contents
Page
6.1
6.2
6.3
Operational Overview E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Device Reset E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Device Initialization in E1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
7
7.1
7.2
7.3
Operational Description T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operational Overview T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device Reset T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device Initialization in T1/J1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
194
194
194
194
8
8.1
8.1.1
8.1.2
8.1.3
8.1.4
8.1.5
8.1.6
8.2
8.3
8.3.1
8.3.2
8.3.3
8.3.4
8.3.5
8.3.6
8.3.7
8.3.8
Signaling Controller Operating Modes . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non-Auto Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transparent Mode 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transparent Mode 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SS7 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Extended Transparent Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Signaling Controller Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transparent Transmission and Reception . . . . . . . . . . . . . . . . . . . . . .
CRC on/off Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive Address Pushed to RFIFO . . . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Data Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Data Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sa-bit Access (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bit Oriented Message Mode (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Link Access in ESF/F72 Format (T1/J1) . . . . . . . . . . . . . . . . . . .
201
201
201
202
202
202
202
204
204
205
205
205
206
206
208
208
209
211
9
9.1
9.2
9.3
9.4
E1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E1 Control Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Detailed Description of E1 Control Registers . . . . . . . . . . . . . . . . . . . . .
E1 Status Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Detailed Description of E1 Status Registers . . . . . . . . . . . . . . . . . . . . . .
213
213
217
286
289
10
10.1
10.2
10.3
10.4
T1/J1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T1/J1 Control Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Detailed Description of T1/J1 Control Registers . . . . . . . . . . . . . . . . . . .
T1/J1 Status Register Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Detailed Description of T1/J1 Status Registers . . . . . . . . . . . . . . . . . . . .
330
330
334
407
409
11
11.1
11.2
11.3
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
446
446
446
447
Data Sheet
7
2002-08-27
FALC56 V1.2
PEB 2256
Table of Contents
Page
11.4
11.4.1
11.4.2
11.4.3
11.4.4
11.4.4.1
11.4.4.2
11.4.5
11.4.6
11.4.7
11.4.7.1
11.4.7.2
11.5
11.6
11.7
11.7.1
11.7.2
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Master Clock Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Boundary Scan Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Microprocessor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intel Bus Interface Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motorola Bus Interface Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pulse Templates - Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pulse Template E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pulse Template T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Capacitances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
Package Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
13
13.1
13.2
13.3
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Software Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484
Data Sheet
8
450
450
451
452
453
453
456
458
460
472
472
473
474
474
475
475
476
480
480
481
481
2002-08-27
FALC56 V1.2
PEB 2256
List of Figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
Figure 26
Figure 27
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42
Data Sheet
Page
Logic Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Multiple E1/T1/J1 Link over Frame Relay . . . . . . . . . . . . . . . . . . . . . . 24
8-Channel E1/T1/J1-Interface to the ATM Layer . . . . . . . . . . . . . . . . . 25
Pin Configuration P-MQFP-80-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Pin Configuration P-LBGA-81-1 (bottom view) . . . . . . . . . . . . . . . . . . 27
Pin Configuration P-LBGA-81-1 (top view) . . . . . . . . . . . . . . . . . . . . . 28
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
FIFO Word Access (Intel Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
FIFO Word Access (Motorola Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Interrupt Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Block Diagram of Test Access Port and Boundary Scan . . . . . . . . . . . 57
Flexible Master Clock Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Receive Clock System (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Receiver Configuration (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Receive Line Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Protection Switching Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Jitter Attenuation Performance (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Jitter Tolerance (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
The Receive Elastic Buffer as Circularly Organized Memory . . . . . . . 72
Automatic Handling of Errored Signaling Units . . . . . . . . . . . . . . . . . . 75
2.048 MHz Receive Signaling Highway (E1) . . . . . . . . . . . . . . . . . . . . 77
CRC4 Multiframe Alignment Recovery Algorithms (E1). . . . . . . . . . . . 89
Transmitter Configuration (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Transmit Clock System (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Transmit Line Monitor Configuration (E1) . . . . . . . . . . . . . . . . . . . . . . 99
2.048 MHz Transmit Signaling Highway (E1) . . . . . . . . . . . . . . . . . . 101
System Interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Receive System Interface Clocking (E1) . . . . . . . . . . . . . . . . . . . . . . 105
SYPR Offset Programming (2.048 Mbit/s, 2.048 MHz) . . . . . . . . . . . 107
SYPR Offset Programming (8.192 Mbit/s, 8.192 MHz) . . . . . . . . . . . 107
RFM Offset Programming (2.048 Mbit/s, 2.048 MHz) . . . . . . . . . . . . 108
RFM Offset Programming (8.192 Mbit/s, 8.192 MHz) . . . . . . . . . . . . 108
Transmit System Interface Clocking: 2.048 MHz (E1) . . . . . . . . . . . . 109
Transmit System Interface Clocking: 8.192 MHz/4.096 Mbit/s (E1). . 110
SYPX Offset Programming (2.048 Mbit/s, 2.048 MHz) . . . . . . . . . . . 112
SYPX Offset Programming (8.192 Mbit/s, 8.192 MHz) . . . . . . . . . . . 112
Remote Loop (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Payload Loop (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Local Loop (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Single Channel Loop-Back (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Receive Clock System (T1/J1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Receiver Configuration (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
9
2002-08-27
FALC56 V1.2
PEB 2256
List of Figures
Figure 43
Figure 44
Figure 45
Figure 46
Figure 47
Figure 48
Figure 49
Figure 50
Figure 51
Figure 52
Figure 53
Figure 54
Figure 55
Figure 56
Figure 57
Figure 58
Figure 59
Figure 60
Figure 61
Figure 62
Figure 63
Figure 64
Figure 65
Figure 66
Figure 67
Figure 68
Figure 69
Figure 70
Figure 71
Figure 72
Figure 73
Figure 74
Figure 75
Figure 76
Figure 77
Figure 78
Figure 79
Figure 80
Figure 81
Figure 82
Figure 83
Figure 84
Data Sheet
Page
Receive Line Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protection Switching Application . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jitter Attenuation Performance (T1/J1) . . . . . . . . . . . . . . . . . . . . . . .
Jitter Tolerance (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Receive Elastic Buffer as Circularly Organized Memory . . . . . .
Automatic Handling of Errored Signaling Units . . . . . . . . . . . . . . . . .
Influences on Synchronization Status (T1/J1) . . . . . . . . . . . . . . . . . .
Transmitter Configuration (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clocking in Remote Loop Configuration (T1/J1) . . . . . . . . . . . . . . . .
Transmit Clock System (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Line Monitor Configuration (T1/J1) . . . . . . . . . . . . . . . . . . .
System Interface (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive System Interface Clocking (T1/J1) . . . . . . . . . . . . . . . . . . . .
SYPR Offset Programming (1.544 Mbit/s, 1.544 MHz) . . . . . . . . . . .
SYPR Offset Programming (6.176 Mbit/s, 6.176 MHz) . . . . . . . . . . .
RFM Offset Programming (1.544 Mbit/s, 1.544 MHz) . . . . . . . . . . . .
RFM Offset Programming (6.176 Mbit/s, 6.176 MHz) . . . . . . . . . . . .
2.048 MHz Receive Signaling Highway (T1/J1). . . . . . . . . . . . . . . . .
Receive FS/DL-Bits in Time Slot 0 on RDO (T1/J1) . . . . . . . . . . . . .
1.544 MHz Receive Signaling Highway (T1/J1). . . . . . . . . . . . . . . . .
Transmit System Clocking: 1.544 MHz (T1/J1) . . . . . . . . . . . . . . . . .
Transmit System Clocking: 8.192 MHz/4.096 Mbit/s (T1/J1) . . . . . . .
2.048 MHz Transmit Signaling Clocking (T1/J1) . . . . . . . . . . . . . . . .
1.544 MHz Transmit Signaling Highway (T1/J1) . . . . . . . . . . . . . . . .
Signaling Marker for CAS/CAS-CC Applications (T1/J1) . . . . . . . . . .
Signaling Marker for CAS-BR Applications (T1/J1) . . . . . . . . . . . . . .
Transmit FS/DL Bits on XDI (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . .
SYPX Offset Programming (1.544 Mbit/s, 1.544 MHz) . . . . . . . . . . .
SYPX Offset Programming (6.176 Mbit/s, 6.176 MHz) . . . . . . . . . . .
Remote Loop (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Payload Loop (T1/J1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local Loop (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Channel Loop-Back (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Receive Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Transmit Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Driven Data Transmission (flow diagram) . . . . . . . . . . . . . .
Interrupt Driven Transmission Example . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Driven Reception Sequence Example . . . . . . . . . . . . . . . . .
MCLK Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Boundary Scan Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intel Non-Multiplexed Address Timing . . . . . . . . . . . . . . . . . . . . . . . .
10
123
124
127
128
133
136
141
155
156
157
160
166
167
169
169
170
170
171
171
172
173
174
175
175
176
177
178
179
179
182
183
184
185
203
204
207
207
208
450
451
452
453
2002-08-27
FALC56 V1.2
PEB 2256
List of Figures
Figure 85
Figure 86
Figure 87
Figure 88
Figure 89
Figure 90
Figure 91
Figure 92
Figure 93
Figure 94
Figure 95
Figure 96
Figure 97
Figure 98
Figure 99
Figure 100
Figure 101
Figure 102
Figure 103
Figure 104
Figure 105
Figure 106
Figure 107
Figure 108
Figure 109
Figure 110
Data Sheet
Page
Intel Multiplexed Address Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intel Read Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intel Write Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motorola Read Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motorola Write Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Line Interface Receive Timing . . . . . . . . . . . . . . . . . . . . . . . .
Digital Line Interface Transmit Timing . . . . . . . . . . . . . . . . . . . . . . . .
RCLK, RFSP Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCLKR/SCLKX Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Interface Marker Timing (Receive) . . . . . . . . . . . . . . . . . . . .
SYPR, SYPX Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Interface Marker Timing (Transmit). . . . . . . . . . . . . . . . . . . .
XDI, XSIG Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TCLK Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XCLK Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FSC Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SYNC Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E1 Pulse Shape at Transmitter Output . . . . . . . . . . . . . . . . . . . . . . .
T1 Pulse Shape at the Cross Connect Point . . . . . . . . . . . . . . . . . . .
Thermal Behavior of Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input/Output Waveforms for AC Testing . . . . . . . . . . . . . . . . . . . . . .
Device Configuration for Power Supply Testing . . . . . . . . . . . . . . . .
Protection Circuitry Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Master Clock Frequency Calculator . . . . . . . . . . . . . . . . . . . . . . . . . .
External Line Frontend Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
453
454
454
456
456
458
458
460
461
462
463
465
466
467
468
469
470
471
472
473
474
475
476
480
482
483
2002-08-27
FALC56 V1.2
PEB 2256
List of Tables
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24
Table 25
Table 26
Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Data Sheet
Page
Pin Definitions - Microprocessor Interface . . . . . . . . . . . . . . . . . . . . . . 29
Pin Definitions - Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Pin Definitions - Clock Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Pin Definitions - System Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Pin Definitions - Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Data Bus Access (16-Bit Intel Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Data Bus Access (16-Bit Motorola Mode) . . . . . . . . . . . . . . . . . . . . . . 52
Selectable Bus and Microprocessor Interface Configuration . . . . . . . . 53
TAP Controller Instruction Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
RCLK Output Selection (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Recommended Receiver Configuration Values (E1) . . . . . . . . . . . . . 63
External Component Recommendations (Monitoring) . . . . . . . . . . . . . 64
System Clocking (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Output Jitter (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Receive Buffer Operating Modes (E1) . . . . . . . . . . . . . . . . . . . . . . . . . 71
Allocation of Bits 1 to 8 of Time Slot 0 (E1) . . . . . . . . . . . . . . . . . . . . . 80
Transmit Transparent Mode (Doubleframe E1) . . . . . . . . . . . . . . . . . . 81
CRC-Multiframe Structure (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Transmit Transparent Mode (CRC Multiframe E1) . . . . . . . . . . . . . . . 84
Summary of Alarm Detection and Release (E1) . . . . . . . . . . . . . . . . . 90
Recommended Transmitter Configuration Values (E1) . . . . . . . . . . . . 95
Transmit Buffer Operating Modes (E1) . . . . . . . . . . . . . . . . . . . . . . . . 98
System Clocking and Data Rates (E1) . . . . . . . . . . . . . . . . . . . . . . . 102
Time Slot Assigner HDLC Channel 1 (E1) . . . . . . . . . . . . . . . . . . . . . 113
RCLK Output Selection (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Recommended Receiver Configuration Values (T1/J1). . . . . . . . . . . 122
External Component Recommendations (Monitoring) . . . . . . . . . . . . 123
System Clocking (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Output Jitter (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Channel Translation Modes (DS1/J1) . . . . . . . . . . . . . . . . . . . . . . . . 131
Receive Buffer Operation Modes (T1/J1) . . . . . . . . . . . . . . . . . . . . . 132
Resynchronization Timing (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
4-Frame Multiframe Structure (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . 142
12-Frame Multiframe Structure (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . 143
Extended Superframe Structure (F24, ESF; T1/J1) . . . . . . . . . . . . . . 144
72-Frame Multiframe Structure (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . 148
Summary Frame Recover/Out of Frame Conditions (T1/J1) . . . . . . . 149
Summary of Alarm Detection and Release (T1/J1) . . . . . . . . . . . . . . 150
Recommended Transmitter Configuration Values (T1/J1). . . . . . . . . 155
Transmit Buffer Operating Modes (T1/J1) . . . . . . . . . . . . . . . . . . . . . 159
Pulse Shaper Programming (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . 159
Structure of Periodical Performance Report (T1/J1) . . . . . . . . . . . . . 163
12
2002-08-27
FALC56 V1.2
PEB 2256
List of Tables
Table 43
Table 44
Table 45
Table 46
Table 47
Table 48
Table 49
Table 50
Table 51
Table 52
Table 53
Table 54
Table 55
Table 56
Table 57
Table 58
Table 59
Table 60
Table 61
Table 62
Table 63
Table 64
Table 65
Table 66
Table 67
Table 68
Table 69
Table 70
Table 71
Table 72
Table 73
Table 74
Table 75
Table 76
Table 77
Table 78
Table 79
Table 80
Table 81
Table 82
Table 83
Table 84
Data Sheet
Page
Bit Functions in Periodical Performance Report . . . . . . . . . . . . . . . .
System Clocking and Data Rates (T1/J1) . . . . . . . . . . . . . . . . . . . . .
Time Slot Assigner HDLC Channel 1 (T1/J1) . . . . . . . . . . . . . . . . . .
Initial Values after Reset (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialization Parameters (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Line Interface Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Framer Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Controller Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAS-CC Initialization (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initial Values after reset and FMR1.PMOD = 1 (T1/J1) . . . . . . . . . . .
Initialization Parameters (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Line Interface Initialization (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Framer Initialization (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HDLC Controller Initialization (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . .
Initialization of the CAS-BR Controller (T1/J1). . . . . . . . . . . . . . . . . .
E1 Control Register Address Arrangement . . . . . . . . . . . . . . . . . . . .
Transmit CAS Registers (E1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clock Mode Register Settings for E1 or T1/J1 . . . . . . . . . . . . . . . . . .
E1 Status Register Address Arrangement . . . . . . . . . . . . . . . . . . . . .
Receive CAS Registers (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T1/J1 Control Register Address Arrangement . . . . . . . . . . . . . . . . . .
Pulse Shaper Programming (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . .
Transmit Signaling Registers (T1/J1). . . . . . . . . . . . . . . . . . . . . . . . .
Clock Mode Register Settings for E1 or T1/J1 . . . . . . . . . . . . . . . . . .
T1/J1 Status Register Address Arrangement . . . . . . . . . . . . . . . . . .
Alarm Simulation States. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive Signaling Registers (T1/J1) . . . . . . . . . . . . . . . . . . . . . . . . .
MCLK Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Boundary Scan Timing Parameter Values. . . . . . . . . . . . . . . .
Reset Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intel Bus Interface Timing Parameter Values . . . . . . . . . . . . . . . . . .
Motorola Bus Interface Timing Parameter Values . . . . . . . . . . . . . . .
Digital Line Interface Parameter Values . . . . . . . . . . . . . . . . . . . . . .
RCLK, RFSP Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . .
SCLKR/SCLKX Timing Parameter Values. . . . . . . . . . . . . . . . . . . . .
System Interface Marker Timing Parameter Values . . . . . . . . . . . . .
SYPR/SYPX Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . .
System Interface Marker Timing Parameter Values . . . . . . . . . . . . .
XDI, XSIG Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . .
TCLK Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XCLK Timing Parameter values. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
164
165
180
188
190
191
192
192
193
194
197
198
199
200
200
213
263
280
286
322
330
361
383
401
407
415
438
450
451
452
455
457
459
460
461
462
463
465
466
467
468
469
2002-08-27
FALC56 V1.2
PEB 2256
List of Tables
Table 85
Table 86
Table 87
Table 88
Table 89
Table 90
Table 91
Data Sheet
Page
FSC Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SYNC Timing Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T1 Pulse Template at Cross Connect Point (T1.102) . . . . . . . . . . . .
Package Characteristic Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply Test Conditions E1 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply Test Conditions T1/J1 . . . . . . . . . . . . . . . . . . . . . . . . .
14
470
471
473
474
475
476
477
2002-08-27
FALC56 V1.2
PEB 2256
Preface
The FALC56 framer and line interface component is designed to fulfill all required
interfacing between an analog E1/T1/J1 line and the digital PCM system highway/H.100
bus.
The digital functions as well as the analog characteristics are configured via a flexible
microprocessor interface.
Data Sheet
15
2002-08-27
FALC56 V1.2
PEB 2256
Organization of this Document
This Data Sheet is organized as follows:
• Chapter 1, Introduction
Gives a general description of the product and its family, lists the key features, and
presents some typical applications.
• Chapter 2, Pin Descriptions
Lists pin locations with associated signals, categorizes signals according to function,
and describes signals.
• Chapter 3 to Chapter 5, Functional Description E1/T1/J1
These chapters describe the functional blocks and principle operation modes,
organized into separate sections for E1 and T1/J1 operation
• Chapter 6 and Chapter 7, Operational Description E1/T1/J1
Shows the operation modes and how they are to be initialized (separately for E1 and
T1/J1).
• Chapter 8, Signaling Controller Operating Modes
Describes signaling controller functions for both E1 and T1/J1 operation.
• Chapter 9 and Chapter 10, E1 Registers and T1/J1 Registers
Gives a detailed description of all implemented registers and how to use them in
different applications/configurations.
• Chapter 11, Electrical Characteristics
Specifies maximum ratings, DC and AC characteristics.
• Chapter 12, Package Outlines
Shows the mechanical values of the device packages.
• Chapter 13, Appendix
Gives an example for overvoltage protection and information about application notes
and other support.
• Chapter 14, Glossary
• Index
Data Sheet
16
2002-08-27
FALC56 V1.2
PEB 2256
Related Documentation
A detailed description of changes from version 1.1 to 1.2 is given in the "PEB 2256
Version 1.2 Delta Sheet".
This document refers to the following international standards
(in alphabetical/numerical order):
ANSI/EIA-656
ANSI T1.102
ANSI T1.403
AT&T PUB 43802
AT&T PUB 54016
AT&T PUB 62411
ESD Ass. Standard EOS/ESD-5.1-1993
ETSI ETS 300 011
ETIS ETS 300 166
ETSI ETS 300 233
ETSI ETS 300 324
ETSI ETS 300 347
ETSI TBR12
ETSI TBR13
FCC Part68
GR-253-CORE
GR-499-CORE
GR-1089-CORE
H.100
H-MVIP
IEEE 1149.1
ITU-T G.703
ITU-T G.704
ITU-T G.705
ITU-T G.706
ITU-T G.732
ITU-T G.735
ITU-T G.736
ITU-T G.737
ITU-T G.738
ITU-T G.739
ITU-T G.823
ITU-T G.824
ITU-T G.962
ITU-T G.963
ITU-T G.964
ITU-T I.431
ITU-Q.703
JT-G703
JT-G704
JT-G706
JT-I431
MIL-Std. 883D
TR-TSY-000009
UL 1459
Your Comments
We welcome your comments on this document. We are continuously trying improving
our documentation. Please send your remarks and suggestions by e-mail to
[email protected]
Please provide in the subject of your e-mail:
device name (FALC56), device number (PEB 2256 HT), device version (Version 1.2),
and in the body of your e-mail:
document type (Data Sheet), issue date (2002-08-27) and document revision number
(DS 3).
Data Sheet
17
2002-08-27
FALC56 V1.2
PEB 2256
Introduction
1
Introduction
The FALC56 framer and line interface component is designed to fulfill all required
interfacing between analog E1/T1/J1 lines and the digital PCM system highway,
H.100/H.110 or H-MVIP bus for world market telecommunication systems.
Due to its multitude of implemented functions, it fits to a wide range of networking
applications and fulfills the according international standards. An integrated signaling
controller including Signaling System #7 (SS7) support reduces software overhead.
Crystal-less jitter attenuation with only one master clock source reduces the amount of
required external components.
Equipped with a flexible microprocessor interface, it connects to any control processor
environment. A standard boundary scan interface is provided to support board level
testing. Flat pack or BGA device packaging, minimum number of external components
and low power consumption lead to reduced overall system costs.
Other members of the FALC® family are the FALC®54 for short-haul applications, the
FALC®-LH for long-haul and short-haul applications as well as the QuadFALC
supporting four channels on a single chip.
Data Sheet
18
2002-08-27
E1/T1/J1 Framer and Line Interface Component for
Long- and Short-Haul Applications
FALC56
PEB 2256 HT
Version 1.2
1.1
Features
Line Interface
• High-density, generic interface for all
E1/T1/J1 applications
• Analog receive and transmit circuits for long-haul and
short-haul applications
P-MQFP-80-1
• E1 or T1/J1 mode selectable
• Data and clock recovery using an integrated
digital phase-locked loop
• Maximum line attenuation up to -43 dB at 1024 kHz
(E1)
and up to -36 dB at 772 kHz (T1/J1)
• Programmable transmit pulse shapes for E1 and
T1/J1 pulse masks
• Programmable line build-out for CSU signals
according to ANSI T1. 403 and FCC68: 0dB, -7.5dB,
P-LBGA-81-1
-15dB, -22.5 dB (T1/J1)
• Low transmitter output impedances for high transmit
return loss
• Tristate function of the analog transmit line outputs
• Transmit line monitor protecting the device from damage
• Receive line monitor mode
• Jitter specifications of ITU-T I.431, G.703, G.736 (E1), G.823 (E1) and AT&T
TR62411 (T1/J1) are met
• Crystal-less wander and jitter attenuation/compensation
• Common master clock reference for E1 and T1/J1
(any frequency within 1.02 and 20 MHz)
• Power-down function
Type
Package
PEB 2256 HT
P-MQFP-80-1
PEB 2256 E
P-LBGA-81-1
Data Sheet
19
2002-08-27
FALC56 V1.2
PEB 2256
Introduction
•
•
•
•
•
•
•
•
•
•
Support of automatic protection switching
Dual-rail or single-rail digital inputs and outputs
Unipolar NRZ or CMI for interfacing fiber-optical transmission routes
Selectable line codes (E1: HDB3, AMI/T1: B8ZS, AMI with ZCS)
Loss-of-signal indication with programmable thresholds according to ITU-T G.775,
ETS300233 (E1) and ANSI T1.403 (T1/J1)
Optional data stream muting upon LOS detection
Programmable receive slicer threshold
Clock generator for jitter-free system/transmit clocks per channel
Local loop and remote loop for diagnostic purposes
Low power device, single power supply: 3.3 V with 5 V tolerant digital inputs
Frame Aligner
• Frame alignment/synthesis for 2048 kbit/s according to ITU-T G.704 (E1) and for
1544 kbit/s according to ITU-T G.704 and JT G.704 (T1/J1)
• Programmable frame formats:
E1: Doubleframe, CRC multiframe (E1)
T1: 4-frame multiframe (F4,FT), 12-frame multiframe (F12, D3/4), extended
superframe (F24, ESF), remote switch mode (F72, SLC96)
• Selectable conditions for recover/loss of frame alignment
• CRC4 to non-CRC4 interworking according to ITU-T G. 706 Annex B (E1)
• Error checking via CRC4 procedures according to ITU-T G. 706 (E1)
• Error checking via CRC6 procedures according to ITU-T G. 706 and JT G.706 (T1/J1)
• Performs synchronization in ESF format according to NTT requirements (J1)
• Alarm and performance monitoring per second
16 bit counter for CRC-errors, framing errors, code violations, error monitoring via
E-bit and SA6-bit (E1), errored blocks, PRBS bit errors
• Insertion and extraction of alarm indication signals (AIS, remote/yellow alarm,…)
• Remote alarm generation/checking according to ITU JT-G.704 in ESF-format (J1)
• IDLE code insertion for selectable channels
• Single-bit defect insertion
• Flexible system clock frequency for receiver and transmitter
• Supports programmable system data rates with independent receive/transmit shifts:
E1: 2.048, 4.096, 8.192 and 16.384 Mbit/s (according to H.100/H.110 bus)
T1/J1: 2.048, 4.096, 8.192, 16.384 Mbit/s and 1.544, 3.088, 6.176, 12.352 Mbit/s
• Elastic store for receive and transmit route clock wander and jitter compensation;
controlled slip capability and slip indication
• Programmable elastic buffer size: 2 frames/1 frame/short buffer/bypass
• Provides different time slot mapping modes
• Supports fractional E1 or T1/J1 access
• Flexible transparent modes
• Programmable in-band loop code detection and generation (TR62411)
Data Sheet
20
2002-08-27
FALC56 V1.2
PEB 2256
Introduction
• Channel loop back, line loop back or payload loop back capabilities (TR54016)
• Pseudo-random binary sequence generator and monitor
(framed or unframed)
• Clear channel capabilities (T1/J1)
• Loop-timed mode
Signaling Controller
• Three HDLC controllers
Bit stuffing, CRC check and generation, flag generation, flag and address recognition,
handling of bit oriented functions
• Supports signaling system #7
delimitation, alignment and error detection according to ITU-Q.703
processing of fill in signaling units, processing of errored signaling units
• CAS/CAS-BR controller with last look capability, enhanced CAS-register access and
freeze signaling indication
• DL-channel protocol for ESF format according to ANSI T1.403 specification or
according to AT&T TR54016 (T1/J1)
• DL-bit access for F72 (SLC96) format (T1/J1)
• Generates periodical performance report according to ANSI T1. 403
• Provides access to serial signaling data streams
• Multiframe synchronization and synthesis according to ITU-T G.732
• Alarm insertion and detection (AIS and LOS in time slot 16)
• Transparent mode
• FIFO buffers (64 bytes deep) for efficient transfer of data packets
• Time slot assignment
Any combination of time slots selectable for data transfer independent of signaling
mode (useful for fractional T1/J1 applications)
• Time-slot 0 Sa8...4-bit handling via FIFOs (E1)
• HDLC access to any Sa-bit combination (E1)
Microprocessor Interface
•
•
•
•
•
•
8/16-bit microprocessor bus interface (Intel or Motorola type)
All registers directly accessible (byte or word access)
Multiplexed and non-multiplexed address bus operations
Hard/software reset options
Extended interrupt capabilities
One-second timer (internal or external timing reference)
Data Sheet
21
2002-08-27
FALC56 V1.2
PEB 2256
Introduction
General
•
•
•
•
•
•
Boundary scan standard IEEE 1149.1
P-LBGA-81-1 package; body size 10 mm × 10 mm; ball pitch 1.0 mm or
P-MQFP-80-1 package; body size 14 mm × 14 mm; lead pitch 0.5 mm
Temperature range from -40 to +85 °C
3.3 V power supply, digital inputs 5V tolerant
Typical power consumption 250 mW
Applications
•
•
•
•
•
•
•
•
Wireless basestations
E1/T1/J1 ATM gateways, multiplexer
E1/T1/J1 Channel & Data Service Units (CSU, DSU)
E1/T1/J1 Internet access equipment
LAN/WAN router
ISDN PRI, PABX
Digital Access Crossconnect Systems (DACS)
SONET/SDH add/drop multiplexer
Data Sheet
22
2002-08-27
FALC56 V1.2
PEB 2256
Introduction
1.2
Logic Symbol
Receive
Line
Interface
SEC/FSC
CLK2
CLK1
SYNC
MCLK
RCLK
VDDR
VSSR
System Clocks
RL1/RDIP/ROID
SCLKR
RDO
RL2/RDIN/RCLKI
RPA
RPB
TRS
RPC
TDI
Boundary
Scan
Receive
System
Interface
RPD
TMS
FALC 56
PEB 2256
R
TCK
TDO
SCLKX
XDI
Figure 1
Data Sheet
Transmit
System
Interface
INT
RES
IM
DBW
XPD
ALE
VSSX
BHE/BLE
XPC
RD/DS
VDDX
WR/RW
XPB
CS
XL2/XDON
A0...A7
XPA
D0...D15
XL1/XDOP/XOID
VSS
VDD
Transmit
Line
Interface
Microprocessor Interface
ITL10712
23
2002-08-27
Logic Symbol
FALC56 V1.2
PEB 2256
Introduction
1.3
Typical Applications
The figures show a multiple link application for Frame Relay applications using the
FALC®56 together with the 128-channel HDLC controller M128X and the Memory
Timeswitch MTLS as well as an 8-channel interface to the ATM layer.
•
R
E1/T1/J1
FALC 56
PEB 2256
E1/T1/J1
FALCR 56
PEB 2256
MTSL
PEB 2047
Memory Time Switch
R
E1/T1/J1
FALC 56
PEB 2256
Clocks
E1/T1/J1
FALCR 56
PEB 2256
Clock
Clock
MCLK
MUNICH128X
PEB 20324
PCI/Generic
CPU
System Bus
MEM
ITS10714
Figure 2
Data Sheet
Multiple E1/T1/J1 Link over Frame Relay
24
2002-08-27
FALC56 V1.2
PEB 2256
Introduction
•
Port 1
RAM
FALC R -56
PEB 2256
E1/T1/J1
8 x PCM
UTOPIA
IWE8 R
PXB 4220
Port 8
E1/T1/J1
FALC R -56
PEB 2256
ATM
Layer
AAL1 or ATM-Mode
ITS10715
Figure 3
Data Sheet
8-Channel E1/T1/J1-Interface to the ATM Layer
25
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
2
Pin Descriptions
2.1
Pin Diagram P-MQFP-80-1
XPB
60
61
56
52
48
44
VDD
VSS
A0
A1
A2
A3
A4
A5
A6
A7
ALE
RD/DS
WR/RW
CS
BHE/BLE
XDI
INT
VDD
VSS
XPA
(top view)
41
40
D0
XPC
D1
XPD
D2
SCLKX
D3
64
SCLKR
36
D4
RDO
VSS
RPA
VDD
RPB
D5
68
RPC
32
®
FALC 56
PEB 2256
RPD
VDD
VSS
D6
D7
D8
D9
72
MCLK
28
D10
N.C.
D11
RCLK
D12
CLK1
VSS
76
CLK2
24
VDD
SEC/FSC
D13
SYNC
D14
Figure 4
Data Sheet
N.C.
TDO
TCK
TMS
TDI
TRS
D15
N.C.
21
20
16
RES
DBW
IM
VSS
12
VDD
XL1/XDOP/XOID
VDDX
8
XL2/XDON
VDDR
RL1/RDIP/ROID
RL2/RDIN/RCLKI
4
VSSX
80
1
VSSR
N.C.
F0119_1
Pin Configuration P-MQFP-80-1
26
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
2.2
Pin Diagram P-LBGA-81-1
9
8
7
6
5
4
3
2
1
A
XPB
XPC
SCLKR
RPB
VDD
NC
RCLK
SYNC
VSSR
B
VSS
XPA
XPD
RDO
RPC
CLK1
SEC/
FSC
NC
RL2/
RDIN
C
BHE/
BLE
VDD
INT
SCLKX
VSS
MCLK
CLK2
RL1/
RDIP
XL2/
XDON
D
CS
XDI
W R/
RW
RPA
RPD
XL1/
VDDR VDDX
XDOP
VSSX
E
ALE
A6
RD/DS
A7
NC
VSS
DBW
VDD
IM
F
A5
A3
A1
A4
D8
D11
RES
TMS
TRS
G
A2
A0
D3
D5
D6
VDD
TCK
TDO
TDI
H
VSS
D0
D2
D4
D9
D12
D13
NC
NC
J
VDD
D1
VSS
VDD
D7
D10
VSS
D14
D15
F0119_2
Figure 5
Data Sheet
Pin Configuration P-LBGA-81-1 (bottom view)
27
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
1
2
3
4
5
6
7
8
9
A
VSSR
SYNC
RCLK
NC
VDD
RPB
SCLKR
XPC
XPB
B
RL2/
RDIN
NC
SEC/
FSC
CLK1
RPC
RDO
XPD
XPA
VSS
C
XL2/
XDON
RL1/
RDIP
CLK2
MCLK
VSS
SCLKX
INT
VDD
BHE/
BLE
D
VSSX
VDDX VDDR
XL1/
XDOP
RPD
RPA
WR/
RW
XDI
CS
E
IM
VDD
DBW
VSS
NC
A7
RD/DS
A6
ALE
F
TRS
TMS
RES
D11
D8
A4
A1
A3
A5
G
TDI
TDO
TCK
VDD
D6
D5
D3
A0
A2
H
NC
NC
D13
D12
D9
D4
D2
D0
VSS
J
D15
D14
VSS
D10
D7
VDD
VSS
D1
VDD
F0119_3
Figure 6
Data Sheet
Pin Configuration P-LBGA-81-1 (top view)
28
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
2.3
Pin Definitions and Functions
•
Table 1
Pin Definitions - Microprocessor Interface
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
50
49
48
47
46
45
44
43
E6
E8
F9
F6
F8
G9
F7
G8
A7
A6
A5
A4
A3
A2
A1
A0
I + PU
Address Bus
These inputs interface with eight bits of the
system’s address bus to select one of the
internal registers for read or write.
21
22
23
26
27
28
29
30
31
32
33
36
37
38
39
40
J1
J2
H3
H4
F4
J4
H5
F5
J5
G5
G6
H6
G7
H7
J8
H8
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
I/O + PU
Data Bus
Bidirectional tristate data lines which interface
with the system’s data bus. Their configuration
is controlled by the level of pin DBW:
8-bit mode (DBW = 0): D(7:0) are active.
D(15:8) are internally pulled high.
16-bit mode (DBW = 1): D(15:0) are active.
In case of byte transfers, the active half of the
bus is determined by A0 and BHE/BLE and the
selected bus interface mode (via pin IM). The
unused half is internally pulled high.
Data Sheet
29
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 1
Pin Definitions - Microprocessor Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
51
E9
ALE
I + PU
Address Latch Enable
A high on this line indicates an address on an
external multiplexed address/data bus. The
address information provided on lines A(7:0) is
internally latched with the falling edge of ALE.
This function allows the FALC®56 to be
connected to a multiplexed address/data bus
without the need for external latches. In this
case, pins A(7:0) must be connected to the
data bus pins externally. In case of
demultiplexed mode this pin can be connected
directly to VDD or can be left open.
52
E7
RD/DS
I + PU
Read Enable (Intel bus mode)
This signal indicates a read operation. When
the FALC®56 is selected via CS, the RD signal
enables the bus drivers to output data from an
internal register addressed by A(7:0) to the
Data Bus.
Data Strobe (Motorola bus mode)
This pin serves as input to control read/write
operations.
53
D7
WR/RW
I + PU
WRite Enable (Intel bus mode)
This signal indicates a write operation. When
CS is active the FALC®56 loads an internal
register with data provided on the data bus.
Read/Write Enable (Motorola bus mode)
This signal distinguishes between read and
write operation.
12
E3
DBW
I + PU
Data Bus Width (Bus interface mode)
A low signal on this input selects the 8-bit bus
interface mode. A high signal on this input
selects the 16-bit bus interface mode. In this
case word transfer to/from the internal
registers is enabled. Byte transfers are
implemented by using A0 and BHE/BLE.
Data Sheet
30
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 1
Pin Definitions - Microprocessor Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
11
E1
IM
I + PU
Interface Mode
The level at this pin defines the bus interface
mode:
A low signal on this input selects the Intel
interface mode. A high signal on this input
selects the Motorola interface mode.
54
D9
CS
I + PU
Chip Select
A low signal selects the FALC®56 for read and
write operations. This allows to connect
multiple devices to a single data/address bus.
55
C9
BHE/
BLE
I + PU
Bus High Enable (Intel bus mode)
If 16-bit bus interface mode is enabled, this
signal indicates a data transfer on the upper
byte of the data bus D(15:8). In 8-bit bus
interface mode this signal has no function and
should be tied to VDD or left open.
Bus Low Enable (Motorola bus mode)
If 16-bit bus interface mode is enabled, this
signal indicates a data transfer on the lower
byte of the data bus D(7:0). In 8-bit bus
interface mode this signal has no function and
should be tied to VDD or left open.
57
C7
Data Sheet
INT
O/oD
INTerrupt Request
INT serves as general interrupt request for all
interrupt sources. These interrupt sources can
be masked via registers IMR(5:0). Interrupt
status is reported via registers GIS (Global
Interrupt Status) and ISR(5:0).
Output characteristics (push-pull active low/
high, open drain) are determined by
programming register IPC.
(oD = open drain output)
31
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
•
Table 2
Pin
No.
Pin Definitions - Line Interface
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
Line Interface Receive
3
C2
RL1
I (analog)
Line Receiver 1
Analog input from the external transformer.
Selected if LIM1.DRS is cleared.
RDIP
I
Receive Data Input Positive
Digital input for received dual-rail PCM(+) route
signal which is latched with the internally
recovered receive route clock. An internal
DPLL extracts the receive route clock from the
incoming data pulses. The duty cycle of the
received signal has to be close to 50%.
The dual-rail mode is selected if LIM1.DRS
and FMR0.RC1 are set. Input polarity is
selected by bit RC0.RDIS (after reset: active
low), line coding is selected by FMR0.RC(1:0).
ROID
I
Receive Optical Interface Data
Unipolar data received from a fiber-optical
interface with 2048 kbit/s (E1) or 1544 kbit/s
(T1/J1). Latching of data is done with the falling
edge of RCLKI. Input polarity is selected by bit
RC0.RDIS.
The single-rail mode is selected if LIM1.DRS is
set and FMR0.RC1 is cleared.
If CMI coding is selected
(FMR0.RC(1:0) = 01), an internal DPLL
recovers clock an data; no clock signal on
RCLKI is required.
Data Sheet
32
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 2
Pin Definitions - Line Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
2
B1
RL2
I (analog)
Line Receiver 2
Analog input from the external transformer.
Selected if LIM1.DRS is cleared.
RDIN
I
Receive Data Input Negative
Input for received dual-rail PCM(-) route signal
which is latched with the internally recovered
receive route clock. An internal DPLL extracts
the receive route clock from the incoming data
pulses. The duty cycle of the received signal
has to be close to 50%.
The dual-rail mode is selected if LIM1.DRS
and FMR0.RC1 are set. Input polarity is
selected by bit RC0.RDIS (after reset: active
low), line coding is selected by FMR0.RC(1:0).
RCLKI
I
Receive Clock Input
Receive clock input for the optical interface if
LIM1.DRS is set and FMR0.RC(1:0) = 00.
Clock frequency: 2.048 MHz (E1) or
1.544 MHz (T1/J1).
RCLKI is ignored if CMI coding is selected.
Data Sheet
33
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 2
Pin
No.
Pin Definitions - Line Interface (cont’d)
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
Line Interface Transmit
7
D4
Data Sheet
XL1
O (analog) Transmit Line 1
Analog output to the external transformer.
Selected if LIM1.DRS is cleared. After reset
this pin is in high-impedance state until bit
FMR0.XC1 is set and XPM2.XLT is cleared.
XDOP
O
Transmit Data Output Positive
This digital output for transmitted dual-rail
PCM(+) route signals can provide
- half bauded signals with 50% duty cycle
(LIM0.XFB = 0) or
- full bauded signals with 100% duty cycle
(LIM0.XFB = 1)
The data is clocked with positive transitions of
XCLK in both cases. Output polarity is selected
by bit LIM0.XDOS (after reset: active low). The
dual-rail mode is selected if LIM1.DRS and
FMR0.XC1 are set. After reset this pin is in
high-impedance state until register LIM1.DRS
is set and XPM2.XLT is cleared.
XOID
O
Transmit Optical Interface Data
Unipolar data sent to a fiber-optical interface
with 2048 kbit/s (E1) or 1544 kbit/s (T1/J1)
which is clocked on the positive transitions of
XCLK. Clocking of data in NRZ code is done
with 100% duty cycle. Data in CMI code is
shifted out with 50% or 100% duty cycle on
both transitions of XCLK according to the CMI
coding. Output polarity is selected by bit
LIM0.XDOS (after reset: data is sent active
high).
The single-rail mode is selected if LIM1.DRS is
set and FMR0.XC1 is cleared. After reset this
pin is in high-impedance state until register
LIM1.DRS is set and XPM2.XLT is cleared.
34
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 2
Pin Definitions - Line Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
5
C1
XL2
O (analog) Transmit Line 2
Analog output for the external transformer.
Selected if LIM1.DRS is cleared. After reset
this pin is in high-impedance state until bit
FMR0.XC1 is set and XPM2.XLT is cleared.
XDON
O
Transmit Data Output Negative
This digital output for transmitted dual-rail
PCM(-) route signals can provide
- half bauded signals with 50% duty cycle
(LIM0.XFB = 0) or
- full bauded signals with 100% duty cycle
(LIM0.XFB = 1)
The data is clocked on positive transitions of
XCLK in both cases. Output polarity is selected
by bit LIM0.XDOS (after reset: active low).
The dual-rail mode is selected if LIM1.DRS
and FMR0.XC1 are set. After reset this pin is in
high-impedance state until register LIM1.DRS
is set and XPM2.XLT cleared.
XFM
O
Transmit Frame Marker
This digital output marks the first bit of every
frame transmitted on port XDOP. This function
is only available in the optical interface mode
(LIM1.DRS = 1 and FMR0.XC1 = 0). Data is
clocked on positive transitions of XCLK. After
reset this pin is in high-impedance state until
register LIM1.DRS is set and XPM2.XLT
cleared.
In remote loop configuration the XFM marker is
not valid.
Data Sheet
35
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
•
Table 3
Pin Definitions - Clock Generation
Pin
No.
Pin
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
73
C4
MCLK
I
Master Clock
A reference clock of better than ± 32 ppm
accuracy in the range of 1.02 to 20 MHz must
be provided on this pin. The FALC®56
internally derives all necessary clocks from this
master
(see registers GCM(6:1)).
79
A2
SYNC
I + PU
Clock Synchronization of DCO-R
If a clock is detected on pin SYNC the
DCO-R circuitry of the FALC®56 synchronizes
to this 1.544/2.048 MHz clock (see LIM0.MAS,
CMR1.DCS and CMR2.DCF). Additionally, in
master mode the FALC®56 is able to
synchronize to an 8-kHz reference clock
(IPC.SSYF = 1). If not connected, an internal
pullup transistor ensures high input level.
76
B4
CLK1
O + PU
System Clock of DCO-R
Output of the de-jittered system clock
generated by the DCO-R circuit. Frequency
selection is done by setting control bits in PC5/
6.
E1: 16.384 MHz, 8.192 MHz, 4.096 MHz,
2.048 MHz or 8 kHz
T1/J1: 16.384 MHz, 12.352 MHz, 8.192 MHz,
6.176 MHz, 4.096 MHz, 3.088 MHz, 2.048
MHz, 1.544 MHz or 8 kHz
After reset this output is inactive and internally
pulled high.
Note: If DCO-R is not active, no clock is output
on pin CLK1 (SIC1.RBS(1:0) = 11 and
CMR1.RS1 = 0).
Data Sheet
36
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 3
Pin Definitions - Clock Generation (cont’d)
Pin
No.
Pin
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
77
C3
CLK2
O + PU
System Clock of DCO-X
Output of the de-jittered system clock
generated by the DCO-X circuit. Frequency
selection is done by setting control bits in PC5/
6.
E1: 16.384 MHz, 8.192 MHz, 4.096 MHz or
2.048 MHz
T1/J1: 12.352 MHz, 6.176 MHz, 3.088 MHz or
1.544 MHz
After reset this output is inactive and internally
pulled high.
Note: If DCO-X is not used, no clock is output
on pin CLK2 (SIC1.XBS(1:0) = 00 and
CMR1.DXJA = 1; buffer bypass and no
jitter attenuation)
78
B3
SEC
FSC
Data Sheet
I + PU
One-Second Timer Input
A pulse with logical high level for at least two
2.048-MHz cycles triggers the internal onesecond timer. After reset this pin is configured
to be an input. If not connected, an internal
pullup transistor ensures high input level (see
register GPC1).
O
One-Second Timer Output
Activated high every second for two 2.048MHz clock cycles.
O
Optionally an 8-kHz frame synchronization
pulse is output via this pin. The
synchronization pulse is active high or low for
one 2.048/1.544-MHz cycle (pulse width = 488
ns for E1and 648 ns or T1/J1).
37
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 3
Pin Definitions - Clock Generation (cont’d)
Pin
No.
Pin
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
75
A3
RCLK
O + PU
Receive Clock
After reset this port is configured to be
internally pulled up weakly. Setting of bit
PC5.CRP switches this port to be an active
output.
CMR1.RS(1:0) = 00:
Receive clock extracted from the incoming
data pulses. The clock frequency is 2.048 MHz
(E1) or 1.544 MHz (T1/J1). In case of Loss-OfSignal (LOS) the RCLK is derived from the
clock that is provided on MCLK.
CMR1.RS(1:0) = 01:
Receive clock extracted from the incoming
data pulses. The clock frequency is 2.048 MHz
(E1) or 1.544 MHz (T1/J1). RCLK remains high
in case of LOS (indicated by FRS0.LOS = 1).
CMR1.RS(1:0) = 10:
Dejittered clock generated by the internal
DCO-R circuit. The clock frequency is
2.048 MHz (E1 or T1/J1 and SIC2.SSC2 = 0)
or 1.544 MHz (T1/J1 and SIC2.SSC2 = 1).
CMR1.RS(1:0) = 11:
Dejittered clock generated by the internal
DCO-R circuit. The clock frequency is
8.192 MHz (E1 or T1/J1 and SIC2.SSC2 = 0)
or 6.176 MHz (T1/J1 and SIC2.SSC2 = 1).
Data Sheet
38
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
•
Table 4
Pin
No.
Pin Definitions - System Interface
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
System Interface Receive
66
B6
RDO
O
Receive Data Out
Received data that is sent to the system
highway. Clocking of data is done with the
rising or falling edge (SIC3.RESR) of SCLKR
or RCLK, if the receive elastic store is
bypassed. The delay between the beginning of
time slot 0 and the initial edge of SCLKR (after
SYPR goes active) is determined by the values
of registers RC1 and RC0.
If received data is shifted out with higher (more
than 2.048/1.544 Mbit/s) data rates, the active
channel phase is defined by bits
SIC2.SICS(2:0). During inactive channel
phases RDO is cleared (driven to low level, not
tristate).
65
A7
SCLKR
I/O + PU
System Clock Receive
Working clock for the receive system interface
with a frequency of 16.384/8.192/4.096/2.048
MHz in E1 mode and 16.384/8.192/4.096/
2.048 MHz (SIC2.SSC2 = 0) or 12.352/6.176/
3.088/1.544 MHz (SIC2.SSC2 = 1) in T1/J1
mode. If the receive elastic store is bypassed,
the clock supplied on this pin is ignored,
because RCLK is used to clock the receive
system interface.
If SCLKR is configured to be an output, the
internal working clock of the receive system
interface sourced by DCO-R or RCLK is
output.
Data Sheet
39
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
67
68
69
70
D6
A6
B5
D5
RPA
RPB
RPC
RPD
I/O + PU
Receive Multifunction Port A to D
Depending on programming of bits
PC(1:4).RPC(2:0) these multifunction ports
carry information to the system interface or
from the system to the FALC®56. After reset
these ports are configured to be inputs. With
the selection of the appropriate pin function,
the corresponding input/output configuration is
achieved automatically. Depending on bit
SIC3.RESR latching/transmission of data is
done with the rising or falling edge of SCLKR.
If not connected, an internal pullup transistor
ensures a high input level.
The input function must not be selected twice
or more.
Selectable pin functions are described below.
I + PU
Synchronous Pulse Receive (SYPR)
PC(4:1).RPC(2:0) = 000
Together with the values of registers RC(1:0)
this signal defines the beginning of time slot 0
on system highway port RDO .
Only one multifunction port may be selected as
SYPR input. After reset, SYPR of port A is
used, the other lines are ignored.
SYPR cannot be used in combination with
RFM.
The pulse cycle is an integer multiple of
125 µs.
Data Sheet
40
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
67
68
69
70
D6
A6
B5
D5
RPA
RPB
RPC
RPD
O
Receive Frame Marker (RFM)
PC(4:1).RPC(2:0) = 001
CMR2.IRSP = 0: The receive frame marker
can be active high for a 2.048-MHz (E1) or
1.544-MHz (T1/J1) period during any bit
position of the current frame. It is clocked off
with the rising or falling edge of SCLKR or
RCLK, depending on SIC3.RESR. Offset
programming is done by using registers
RC(1:0).
CMR2.IRSP = 1: Frame synchronization pulse
generated by the DCO-R circuitry internally.
Together with registers RC(1:0) the frame
begin on the receive system interface is
defined. This frame synchronization pulse is
active low for a 2.048-MHz (E1) or 1.544-MHz
(T1/J1) period.
O
Receive Multiframe Begin (RMFB)
PC(1:4).RPC(2:0) = 010
In E1 mode RMFB marks the beginning of
every received multiframe (RDO). Optionally
the time slot 16 CAS multiframe begin can be
marked (SIC3.CASMF). Active high for one
2.048-MHz period.
In T1/J1 mode the function depends on bit
XC0.MFBS:
MFBS = 1: RMFB marks the beginning of
every received multiframe (RDO).
MFBS = 0: RMFB marks the beginning of
every received superframe. Additional pulses
are provided every 12 frames when using ESF/
F24 or F72 format.
Data Sheet
41
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
67
68
69
70
D6
A6
B5
D5
RPA
RPB
RPC
RPD
O
Receive Signaling Marker (RSIGM)
PC(1:4).RPC(2:0) = 011
E1: Marks the time slots which are defined by
register RTR(4:1) of every received frame on
port RDO.
T1/J1: Marks the time slots which are defined
by register RTR(4:1) of every received frame
on port RDO, if CAS-BR is not used.
When using the CAS-BR signaling scheme,
the robbed bit of each channel every sixth
frames is marked, if CAS-BR is enabled by
XC0.BRM = 1.
O
Receive Signaling Data (RSIG)
PC(1:4).RPC(2:0) = 100
The received CAS signaling data is sourced by
this pin. Time slots on RSIG correlate directly
to the time slot assignment on RDO.
O
Data Link Bit Receive (DLR)
PC(1:4).RPC(2:0) = 101
E1: Marks the Sa(8:4)-bits within the data
stream on RDO. The Sa(8:4)-bit positions in
time slot 0 of every frame not containing the
frame alignment signal are selected by register
XC0.
T1/J1: Marks the DL-bit position within the data
stream on RDO.
Data Sheet
42
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
67
68
69
70
D6
A6
B5
D5
RPA
RPB
RPC
RPD
O
Frame Synchronous Pulse (RFSP)
PC(1:4).RPC(2:0) = 111
Active low framing pulse derived from the
received PCM route signal (line side, RCLK).
During loss of synchronization (bit
FRS0.LFA = 1), this pulse is suppressed (not
influenced during alarm simulation).
Pulse frequency: 8 kHz
Pulse width: 488 ns (E1) or 648 ns (T1/J1).
System Interface Transmit
56
D8
XDI
I
Transmit Data In
Transmit data received from the system
highway. Latching of data is done with rising or
falling transitions of SCLKX according to bit
SIC3.RESX.
The delay between the beginning of time slot 0
and the initial edge of SCLKX (after SYPX
goes active) is determined by the registers
XC(1:0).
In higher (more than 1.544/2.048 Mbit/s) data
rates sampling of data is defined by bits
SIC2.SICS(2:0).
64
C6
SCLKX
I + PU
System Clock Transmit
Working clock for the transmit system interface
with a frequency of 16.384/8.192/4.096/2.048
in E1 mode and 16.384/8.192/4.096/2.048
MHz (SIC2.SSC2 = 0) or 12.352/6.176/3.088/
1.544 MHz (SIC2.SSC2 = 1) in T1/J1 mode.
Data Sheet
43
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
60
61
62
63
B8
A9
A8
B7
XPA
XPB
XPC
XPD
I/O + PU
Transmit Multifunction Port A to D
Depending on programming of bits
PC(1:4).XPC(3:0) these multifunction ports
carry information to the system interface or
from the system to the FALC®56. After reset
the ports are configured to be inputs. With the
selection of the appropriate pin function, the
corresponding input/output configuration is
achieved automatically. Depending on bit
SIC3.RESX latching/transmission of data is
done with the rising or falling edge of SCLKX.
If not connected, an internal pullup transistor
ensures a high input level.
Each input function (SYPX, XMFS, XSIG or
TCLK) may only be selected once. SYPX and
XMFS must not be used in parallel.
Selectable pin functions are described below.
Data Sheet
44
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
60
61
62
63
B8
A9
A8
B7
XPA
XPB
XPC
XPD
I + PU
Synchronous Pulse Transmit (SYPX)
PC(1:4).XPC(3:0) = 0000
Together with the values of registers XC(0:1)
this signal defines the beginning of time slot 0
at system highway port XDI .
The pulse cycle is an integer multiple of
125 µs.
SYPX must not be used in parallel with XMFS.
I + PU
Transmit Multiframe Synchronization
(XMFS)
PC(1:4).XPC(3:0) = 0001
This port defines the frame and multiframe
begin on the transmit system interface ports
XDI and XSIG.
Depending on PC5.CXMFS the signal on
XMFS is active high or low.
XMFS must not be used in parallel with SYPX.
Note: A new multiframe position has settled at
least one multiframe after pulse XMFS
has been supplied.
I + PU
Transmit Signaling Data (XSIG)
PC(1:4).XPC(3:0) = 0010
Input for transmit signaling data received from
the signaling highway. Optionally,
(SIC3.TTRF = 1), sampling of XSIG data is
controlled by the active high XSIGM marker. At
higher data rates sampling of data is defined by
bits SIC2.SICS(2:0).
Data Sheet
45
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
60
61
62
63
B8
A9
A8
B7
XPA
XPB
XPC
XPD
I + PU
Transmit Clock (TCLK)
PC(1:4).XPC(3:0) = 0011
A 2.048/8.192-MHz (E1) or 1.544/6.176-MHz
(T1/J1) clock has to be sourced by the system
if the internally generated transmit clock
(generated by DCO-X) shall not be used.
Optionally this input is used as a
synchronization clock for the DCO-X circuitry
with a frequency of 2.048 (E1) or 1.544 MHz
(T1/J1).
O
Transmit Multiframe Begin (XMFB)
PC(1:4).XPC(3:0) = 0100
XMFB marks the beginning of every
transmitted multiframe on XDI. The signal is
active high for one 2.048 (E1) or 1.544 MHz
(T1/J1) period.
O
Transmit Signaling Marker (XSIGM)
PC(1:4).XPC(3:0) = 0101
E1: Marks the transmit time slots on XDI of
every frame which are defined by register
TTR(1:4).
T1/J1: Marks the transmit time slots on XDI of
every frame which are defined by register
TTR(1:4) (if not CAS-BR is used).
When using the CAS-BR signaling scheme the
robbed bit of each channel in every sixth frame
is marked.
Data Sheet
46
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 4
Pin Definitions - System Interface (cont’d)
Pin
No.
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
60
61
62
63
B8
A9
A8
B7
XPA
XPB
XPC
XPD
O
Data Link Bit Transmit (DLX)
PC(1:4).XPC(3:0) = 0110
E1: Marks the Sa(8:4)-bits within the data
stream on XDI. The Sa(8:4)-bit positions in time
slot 0 of every frame not containing the frame
alignment signal are selected by register
XC0.SA8E to XC0.SA4E.
T1/J1: This output provides a 4-kHz signal
which marks the DL-bit position within the data
stream on XDI (in ESF mode only).
O
Transmit Clock (XCLK)
PC(1:4).XPC(3:0) = 0111
Transmit line clock of 2.048 MHz (E1) or
1.544 MHz (T1/J1) derived from SCLKX/R,
RCLK or generated internally by DCO
circuitries.
I + PU
Transmit Line Tristate (XLT)
PC(1:4).XPC(3:0) = 1000
A high level on this port sets the transmit lines
XL1/2 or XDOP/N into tristate mode. This pin
function is logically ored with register bit
XPM2.XLT.
Data Sheet
47
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
•
Table 5
Pin
No.
Pin Definitions - Miscellaneous
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
Power Supply
4
D3
VDDR
S
Positive Power Supply for the analog
receiver
1
A1
VSSR
S
Power Ground for the analog receiver
6
D2
VDDX
S
Positive Power Supply for the analog
transmitter
8
D1
VSSX
S
Power Ground for the analog transmitter
9
24
34
41
58
71
A5
C8
E2
G4
J6
J9
VDD
S
Positive Power Supply
for the digital subcircuits (3.3 V)
For correct operation, all six pins have to be
connected to positive power supply.
10
25
35
42
59
72
B9
C5
E4
H9
J3
J7
VSS
S
Power Ground for digital subcircuits (0 V)
For correct operation, all six pins have to be
connected to ground.
Device Reset
13
F3
Data Sheet
RES
I
Reset
A low signal on this pin forces the FALC®56
into reset state. During reset the FALC®56
needs an active clock on pin MCLK.
During reset all bidirectional output stages are
in input mode, if signal RD is “high” (to disable
the data bus output drivers).
48
2002-08-27
FALC56 V1.2
PEB 2256
Pin Descriptions
Table 5
Pin
No.
Pin Definitions - Miscellaneous (cont’d)
Ball
No.
Symbol
Input (I)
Function
Output (O)
Supply (S)
Unused Pins
19
20
74
80
A4
B2
E5
H1
H2
N.C.
not connected, to be left open for compatibility
with future products.
Boundary Scan/Joint Test Access Group (JTAG)
14
F1
TRS
I + PU
Test Reset for Boundary Scan
(active low). If not connected, an internal pullup
transistor ensures high input level.
If the JTAG boundary scan is not used, this pin
must be connected to RES or VSS.
15
G1
TDI
I + PU
Test Data Input for Boundary Scan
If not connected an internal pullup transistor
ensures high input level.
16
F2
TMS
I + PU
Test Mode Select for Boundary Scan
If not connected an internal pullup transistor
ensures high input level.
17
G3
TCK
I + PU
Test Clock for Boundary Scan
If not connected an internal pullup transistor
ensures high input level.
18
G2
TDO
O
Test Data Output for Boundary Scan
Note: oD = open drain output
PU = input or input/output comprising an internal pullup device
To override the internal pullup by an external pulldown, a resistor value of 22 kΩ
is recommended.
The pullup devices are activated during reset, this means their state is undefined
until the reset signal has been applied.
Unused pins containing pullups can be left open.
Data Sheet
49
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
3
Functional Description E1/T1/J1
3.1
Functional Overview
The FALC® device contains analog and digital function blocks that are configured and
controlled by an external microprocessor or microcontroller.
The main interfaces are
•
•
•
•
Receive and transmit line interface
PCM system highway interface/H.100 bus
Microprocessor interface
Boundary scan interface
as well as several control lines for reset and clocking purpose.
The main internal functional blocks are
•
•
•
•
•
•
•
•
•
•
•
•
Analog line receiver with equalizer network and clock/data recovery
Analog line driver with programmable pulse shaper and line build out
Central clock generation module
Elastic buffers for receive and transmit direction
Receive Framer, receive line decoding, alarm detection, PRBS and performance
monitoring
Transmit framer, receive line encoding, alarm and PRBS generation
Receive jitter attenuator
Transmit jitter attenuator
Three HDLC controllers (one of them including SS7 and BOM support) and CAS
signaling controller
Test functions (loop switching local - remote - payload - single channel)
Register access interface
Boundary scan control
Data Sheet
50
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
3.2
Block Diagram
•
RCLK
Receive Jitter
Attenuator
Remote Loop + JATT
Long+Short
Haul Line
Interface
Local Loop
Clock/Data
Recovery
XL1/XDOP/
XOID
XL2/XDON/
XFM
Receive Framer
Alarm Detector
PRBS Monitor
Line Decoder
Perform. Monitor.
Signaling
Controller
CAS-CC
CAS-BR
Frame Gen.
Alarm Gen.
PRBS Generator
Line Coding
Long + Short
Haul Transmit
Line Interface
Receive Elastic
Buffer
or
Bypass
RDO
RPA
RPB
RPC
RPD
Receive
Backplane
Interface
Payload Loop
RL1/RDIP/
ROID
RL2/RDIN/
RCLKI
SCLKR
HDLC/
BOM/SS7
Controller
Transmit Elastic
Buffer
or
Bypass
XDI
XPA
XPB
XPC
XPD
Transmit
Backplane
Interface
SCLKX
Transmit Jitter
Attenuator
TCLK
RCLK
RCLK TCLK SCLKX
Microprocessor Interface
Intel/Motorola
Boundary Scan
JTAG 1149
TDI TMS TCK TRS TDO
D0...15 A0...7
CS
Figure 7
Data Sheet
WR/RW
ALE
IM RES DBW INT
RD/DS BHE/BLE
Clocking Unit
MCLK
SYNC SEC/FSC
ITS10825
Block Diagram
51
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
3.3
Functional Blocks
3.3.1
Microprocessor Interface
The communication between the CPU and the FALC56 is done using a set of directly
accessible registers. The interface can be configured as Intel or Motorola type with a
selectable data bus width of 8 or 16 bits.
The CPU transfers data to and from the FALC56 (through 64-byte deep FIFOs per
direction), sets the operating modes, controls function sequences, and gets status
information by writing or reading control and status registers. All accesses can be done
as byte or word accesses if enabled. If 16-bit bus width is selected, access to lower/
upper part of the data bus is determined by address line A0 and signal BHE/BLE as
shown in Table 6 and Table 7.
Table 8 shows how the ALE (Address Latch Enable) line is used to control the bus
structure and interface type. The switching of ALE allows the FALC56 to be directly
connected to a multiplexed address/data bus.
3.3.1.1
Mixed Byte/Word Access to the FIFOs
Reading from or writing to the internal FIFOs (RFIFO and XFIFO) can be done using a
8-bit (byte) or 16-bit (word) access depending on the selected bus interface mode.
Randomly mixed byte/word access to the FIFOs is allowed without any restrictions.
Table 6
Data Bus Access (16-Bit Intel Mode)
BHE
A0
Register Access
FALC56 Data Pins Used
0
0
FIFO word access
Register word access (even addresses)
D(15:0)
0
1
Register byte access (odd addresses)
D(15:8)
1
0
Register byte access (even addresses)
D(7:0)
1
1
No transfer performed
None
Table 7
Data Bus Access (16-Bit Motorola Mode)
BLE
A0
Register Access
FALC56 Data Pins Used
0
0
FIFO word access
Register word access (even addresses)
D(15:0)
0
1
Register byte access (odd addresses)
D(7:0)
1
0
Register byte access (even addresses)
D(15:8)
1
1
No transfer performed
None
Data Sheet
52
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
Table 8
Selectable Bus and Microprocessor Interface Configuration
ALE
IM
Microprocessor interface
Bus Structure
VSS/VDD
1
Motorola
de-multiplexed
VSS/VDD
0
Intel
de-multiplexed
switching
0
Intel
multiplexed
The assignment of registers with even/odd addresses to the data lines in case of 16-bit
register access depends on the selected microprocessor interface mode:
Intel
(Address n + 1)
(Address n)
Motorola
(Address n)
(Address n + 1)
↑
↓
Data Lines
D15
↑
↓
D8
D7
D0
n: even address
3.3.1.2
FIFO Structure
In transmit and receive direction of the signaling controller 64-byte deep FIFOs are
provided for the intermediate storage of data between the system internal highway and
the CPU interface. The FIFOs are divided into two halves of 32 bytes. Only one half is
accessible to the CPU at any time.
In case 16-bit data bus width is selected by fixing pin DBW to logical 1 word access to
the FIFOs is enabled. Data output to bus lines D(15:0) as a function of the selected
interface mode is shown in Figure 8 and Figure 9. Of course, byte access is also
allowed. The effective length of the accessible part of RFIFO can be changed from
32 bytes (reset value) down to 2 bytes.
Data Sheet
53
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
RFIFO
XFIFO
32
32
1
1
32
Byte 32
32
Byte 32
4
Byte 4
4
Byte 4
3
Byte 3
3
Byte 3
2
Byte 2
2
Byte 2
1
Byte 1
1
Byte 1
D15
D8
D7
D0
D15
D8
D7
D0
F0112
Figure 8
FIFO Word Access (Intel Mode)
RFIFO
D15
XFIFO
32
32
1
1
32
Byte 32
32
Byte 32
4
Byte 4
4
Byte 4
3
Byte 3
3
Byte 3
2
Byte 2
2
Byte 2
1
Byte 1
1
Byte 1
D8
D7
D0
D15
D8
D7
D0
F0113
Figure 9
Data Sheet
FIFO Word Access (Motorola Mode)
54
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
3.3.1.3
Interrupt Interface
Special events in the FALC® are indicated by means of a single interrupt output with
programmable characteristics (open drain or push-pull, defined by register IPC), which
requests the CPU to read status information from the FALC®, or to transfer data from/to
the FALC®.
Since only one INT request output is provided, the cause of an interrupt must be
determined by the CPU by reading the FALC®’s interrupt status registers (GIS, ISR(5:0)).
The interrupt on pin INT and the interrupt status bits are reset by reading the interrupt
status registers. Register ISR(5:0) are of type “clear on read“.
The structure of the interrupt status registers is shown in Figure 10.
Global
Interrupt
Status
Register GIS
ISR0
ISR0
IMR0
ISR1
ISR2
ISR1
ISR2
IMR1
IMR2
ISR3
ISR4
ISR3
ISR4
IMR3
IMR4
ISR5
ISR5
IMR5
F0127 V1.0
Figure 10
Interrupt Status Registers
Each interrupt indication of registers ISR(5:0) can be selectively masked by setting the
corresponding bit in the corresponding mask registers IMR(5:0). If the interrupt status
bits are masked they neither generate an interrupt at INT nor are they visible in ISR(5:0).
GIS, the non-maskable Global Interrupt Status Register, serves as pointer to pending
interrupts. After the FALC® has requested an interrupt by activating its INT pin, the CPU
should first read the Global Interrupt Status register GIS to identify the requesting
Data Sheet
55
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
interrupt source register. After reading the assigned interrupt status registers ISR(5:0),
the pointer in register GIS is cleared or updated if another interrupt requires service.
If all pending interrupts are acknowledged by reading (GIS is reset), pin INT goes
inactive.
Updating of interrupt status registers ISR(5:0) and GIS is only prohibited during read
access.
Masked Interrupts Visible in Status Registers
• The Global Interrupt Status register (GIS) indicates those interrupt status registers
with active interrupt indications (GIS.ISR(5:0)).
• An additional mode can be selected via bit GCR.VIS.
• In this mode, masked interrupt status bits neither generate an interrupt on pin INT nor
are they visible in GIS, but are displayed in the corresponding interrupt status
register(s) ISR(5:0).
This mode is useful when some interrupt status bits are to be polled in the individual
interrupt status registers.
Note: In the visible mode, all active interrupt status bits, whether the corresponding
actual interrupt is masked or not, are reset when the interrupt status register is
read. Thus, when polling of some interrupt status bits is desired, care must be
taken that unmasked interrupts are not lost in the process.
Note: All unmasked interrupt statuses are treated as before.
Please note that whenever polling is used, all interrupt status registers concerned have
to be polled individually (no “hierarchical” polling possible), since GIS only contains
information on actually generated, i.e. unmasked interrupts.
Data Sheet
56
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
3.3.2
Boundary Scan Interface
In the FALC56 a Test Access Port (TAP) controller is implemented. The essential part
of the TAP is a finite state machine (16 states) controlling the different operational modes
of the boundary scan. Both, TAP controller and boundary scan, meet the requirements
given by the JTAG standard IEEE 1149.1. Figure 11 gives an overview.
TMS
TDI
clock
Clock
Generation
Reset
test
control
BD data in
TAP Controller
data in
enable
finite state machine
instruction register
test signal generator
TDO
control
bus
1
2
Boundary Scan
(n bits)
TCK
TAP controller reset
Identification Register
(32 bits)
TRS
n
ID data out
data
out
BD data out
F0115
Figure 11
Block Diagram of Test Access Port and Boundary Scan
After switching on the device (power-on), a reset signal has to be applied to TRS, which
forces the TAP controller into test logic reset state.
For normal operation without boundary scan access, the boundary reset pin TRS can be
tied to the device reset pin RES.
The boundary length is 129.
Data Sheet
57
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
If no boundary scan operation is used, TRS has to be connected to RST or VSS. TMS,
TCK and TDI do not need to be connected since pullup transistors ensure high input
levels in this case.
Test handling (boundary scan operation) is performed using the pins TCK (Test Clock),
TMS (Test Mode Select), TDI (Test Data Input) and TDO (Test Data Output) when the
TAP controller is not in its reset state, that means TRS is connected to VDD or it remains
unconnected due to its internal pull up. Test data at TDI is loaded with a clock signal
connected to TCK. "1" or "0" on TMS causes a transition from one controller state to
another; constant "1" on TMS leads to normal operation of the chip.
An input pin (I) uses one boundary scan cell (data in), an output pin (O) uses two cells
(data out and enable) and an I/O-pin (I/O) uses three cells (data in, data out and enable).
Note that most functional output and input pins of the FALC56 are tested as I/O pins in
boundary scan, hence using three cells. The desired test mode is selected by serially
loading a 8-bit instruction code into the instruction register through TDI (LSB first).
EXTEST is used to examine the interconnection of the devices on the board. In this test
mode at first all input pins capture the current level on the corresponding external
interconnection line, whereas all output pins are held at constant values ("0" or "1"). Then
the contents of the boundary scan is shifted to TDO. At the same time the next scan
vector is loaded from TDI. Subsequently all output pins are updated according to the new
boundary scan contents and all input pins again capture the current external level
afterwards, and so on.
SAMPLE is a test mode which provides a snapshot of pin levels during normal operation.
IDCODE: A 32-bit identification register is serially read out on pin TDO. It contains the
version number (4 bits), the device code (16 bits) and the manufacturer code (11 bits).
The LSB is fixed to "1".
The ID code field is set to: 0001 0000 0000 0101 1001 0000 1000 0011
Version = 3H, Part Number = 0059H, Manufacturer = 083H (including LSB, fixed to "1")
BYPASS: A bit entering TDI is shifted to TDO after one TCK clock cycle.
An alphabetical overview of all TAP controller operation codes is given in Table 9.
Table 9
TAP Controller Instruction Codes
TAP Instruction
Instruction Code
BYPASS
11111111
EXTEST
00000000
IDCODE
00000100
SAMPLE
00000001
reserved for device test
01010011
Data Sheet
58
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1/T1/J1
3.3.3
Master Clocking Unit
The FALC56 provides a flexible clocking unit, which references to any clock in the range
of 1.02 to 20 MHz supplied on pin MCLK.
The clocking unit has to be tuned to the selected reference frequency by setting the
global clock mode registers GCM(6:1) accordingly.
The calculation formulas for the appropriate register settings can be found in
Chapter 9.2 on page 217 or Chapter 10.2 on page 334. A calculation tool is available
to evaluate the required register settings automatically (see Chapter 13.3 on page 481).
All required clocks for E1 or T1/J1 operation are generated by this circuit internally. The
global setting depends only on the selected master clock frequency and is the same for
E1 and T1/J1 because both clock rates are provided simultaneously.
To meet the E1 requirements the MCLK reference clock must have an accuracy of better
than ± 32 ppm. The synthesized clock can be controlled on pins CLK1, CLK2, RCLK,
SCLKR and XCLK.
.
E1 Clocks
MCLK
Flexible Master Clock Unit
T1 / J1
Clocks
GCM1...GCM6
F0116
Figure 12
Data Sheet
Flexible Master Clock Unit
59
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4
Functional Description E1
4.1
Receive Path in E1 Mode
RL1/RDIP/ROID
RL2/RDIN/RCLKI
Clock &
Data
Recovery
DPLL
Equalizer
Analog
LOS
Detector
Line
Decoder
Alarm
Detector
DCO-R
Receive Jitter
Attenuator
SYNC
RDATA
RCLK
Receive
System
Interface
FSC
F0117
MCLK
Figure 13
4.1.1
Receive Clock System (E1)
Receive Line Interface
For data input, three different data types are supported:
• Ternary coded signals received at multifunction ports RL1 and RL2 from a -10 dB
(short-haul, LIM0.EQON = 0) or -43 dB (long-haul, LIM0.EQON = 1) ternary interface.
The ternary interface is selected if LIM1.DRS is reset.
• Digital dual-rail signals received on ports RDIP and RDIN. The dual-rail interface is
selected if LIM1.DRS and FMR0.RC1 is set.
• Unipolar data on port ROID received from a fiber-optical interface. The optical
interface is selected if LIM1.DRS is set and FMR0.RC1 is reset.
4.1.2
Receive Short and Long-Haul Interface
The FALC56 has an integrated short-haul and long-haul line interface, including a
receive equalization network and noise filtering.
Data Sheet
60
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.1.3
Receive Equalization Network (E1)
The FALC56 automatically recovers the signals received on pins RL1/2 in a range of up
to -43 dB. The maximum reachable length with a 22 AWG twisted pair cable is 1500 m.
After reset the FALC56 is in short-haul“ mode, received signals are recovered up to -10
dB of cable attenuation. Switching in Long-haul“ mode is done by setting of bit
LIM0.EQON.
The integrated receive equalization network recovers signals with up to -43 dB of cable
attenuation. Noise filters eliminate the higher frequency part of the received signals. The
incoming data is peak-detected and sliced to produce the digital data stream. The slicing
level is software selectable in four steps (45%, 50%, 55%, 67%). For typical E1
applications, a level of 50% is used. The received data is then forwarded to the clock &
data recovery unit.
In long-haul mode, the current equalizer status is indicated by register RES (Receive
Equalizer Status).
4.1.4
Receive Line Attenuation Indication (E1)
Status register RES reports the current receive line attenuation in a range from 0 to -43
dB in 25 steps of approximately 1.7 dB each. The least significant 5 bits of this register
indicate the cable attenuation in dB. These 5 bits are only valid in combination with the
most significant two bits (RES.EV1/0 = 01).
4.1.5
Receive Clock and Data Recovery (E1)
The analog received signal on port RL1/2 is equalized and then peak-detected to
produce a digital signal. The digital received signal on port RDIP/N is directly forwarded
to the DPLL. The receive clock and data recovery extracts the route clock from the data
stream received at the RL1/2, RDIP/RDIN or ROID lines and converts the data stream
into a single-rail, unipolar bit stream. The clock and data recovery uses an internally
generated high frequency clock based on MCLK.
The recovered route clock or a de-jittered clock can be output on pin RCLK as shown in
Table 10.
See also Table 13 on page 67 for details of master/slave clocking.
Data Sheet
61
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Table 10
RCLK Output Selection (E1)
Clock Source
RCLK Frequency
CMR1.
DCS
CMR1.
RS1/0
Receive Data
(2.048 Mbit/s on RL1/RL2, RDIP/
RDIN or ROID)
2.048 MHz
(recovered clock)
X
00
Receive Data
in case of LOS
constant high
0
01
2.048 MHz
(generated by DCO-R,
synchronized on SYNC)
1
10
DCO-R
2.048 MHz
X
10
8.192 MHz
X
11
The intrinsic jitter generated in the absence of any input jitter is not more than 0.035 UI.
In digital bipolar line interface mode the clock and data recovery requires HDB3 coded
signals with 50% duty cycle.
4.1.6
Receive Line Coding (E1)
The HDB3 line code or the AMI coding is provided for the data received from the ternary
or the dual-rail interface. In case of the optical interface a selection between the NRZ
code and the CMI Code (1T2B) with HDB3 or AMI postprocessing is provided. If CMI
code is selected the receive route clock is recovered from the data stream. The CMI
decoder does not correct any errors. In case of NRZ coding data is latched with the
falling edge of signal RCLKI. The HDB3 code is used along with double violation
detection or extended code violation detection (selectable by FMR0.EXZE)). In AMI code
all code violations are detected. The detected errors increment the code violation
counter (16 bits length).
When using the optical interface with NRZ coding, the decoder is bypassed and no code
violations are detected.
The signal at the ternary interface is received at both ends of a transformer.
The E1 operating modes 75 Ω or 120 Ω are selectable by switching resistors in parallel
or using special transformers with different transfer ratios in one package (using center
tap). This selection does not require changing transformers.
Data Sheet
62
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
RL1
Line
t2
t1
R
R2
FALC
RL2
ITS10967
Figure 14
Receiver Configuration (E1)
Table 11
Recommended Receiver Configuration Values (E1)
Characteristic Impedance [Ω]
Parameter1)
R2 (± 1%) [Ω]
t2 : t1
1)
120
75
120
75
1:1
1:1
This includes all parasitic effects caused by circuit board design.
4.1.7
Receive Line Monitoring Mode
For short-haul applications like shown in Figure 15, the receive equalizer can be
switched into receive line monitoring mode (LIM0.RLM = 1). One device is used as a
short-haul receiver while the other is used as a short-haul monitor. In this mode the
receiver sensitivity is increased to detect an incoming signal of -20 dB resistive
attenuation. The required resistor values are given in Table 12.
Data Sheet
63
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
t2 : t1
RL1
E1/T1/J1
Receive
Line
FALC®
(Receiver)
R1
RL2
LIM0.RLM=0
R3
R3
t2 : t1
RL1
FALC®
(Monitor)
R2
RL2
resistive -20 dB network
LIM0.RLM=1
F0074
Figure 15
Receive Line Monitoring
Table 12
External Component Recommendations (Monitoring)
Parameter1)
Characteristic Impedance [Ω]
E1
R1 (± 1 %) [Ω]
R2 (± 1 %) [Ω]
R3 (± 1 %) [Ω]
t2 : t1
1)
75
120
75
120
75
120
330
510
1:1
1:1
This includes all parasitic effects caused by circuit board design.
Using the receive line monitor mode and the hardware tristate function of transmit lines
XL1/2, the FALC56 now supports applications connecting two devices to one receive
and transmission line. In these kind of applications both devices are working in parallel
for redundancy purpose (see Figure 16). While one of them is driving the line, the other
one must be switched into transmit line tristate mode. If both channels are configured
identically and supplied with the same system data and clocks, the transmit path can be
switched from one channel to the other without causing a synchronization loss at the
remote end.
Data Sheet
64
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
XL1
E1/T1/J1
Transmit
Line
XDI
XL2
RL1
FALC®
(active)
E1/T1/J1
Receive Line
RDO
RL2
TRIST
1
XL1
XDI
XL2
RL1
FALC®
(stand by)
RDO
RL2
TRIST
F0075
Figure 16
4.1.8
Protection Switching Application
Loss-of-Signal Detection (E1)
There are different definitions for detecting Loss-Of-Signal (LOS) alarms in the ITU-T
G.775 and ETS 300233. The FALC56 covers all these standards. The LOS indication is
performed by generating an interrupt (if not masked) and activating a status bit.
Additionally a LOS status change interrupt is programmable by using register GCR.SCI.
• Detection:
An alarm is generated if the incoming data stream has no pulses (no transitions) for a
certain number (N) of consecutive pulse periods. “No pulse” in the digital receive
interface means a logical zero on pins RDIP/RDIN/ROID. A pulse with an amplitude
less than Q dB below nominal is the criteria for “no pulse” in the analog receive
interface (LIM1.DRS = 0). The receive signal level Q is programmable by three control
Data Sheet
65
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
bits LIM1.RIL(2:0) (see Chapter 11.3 on page 447). The number N can be set by an
8-bit register (PCD). The contents of the PCD register is multiplied by 16, which results
in the number of pulse periods, i.e. the time which has to suspend until the alarm has
to be detected. The programmable range is 16 to 4096 pulse periods. ETS300233
requires detection intervals of at least 1 ms. This time period results always in a LFA
(Loss of Frame Alignment) before a LOS is detected.
• Recovery:
In general the recovery procedure starts after detecting a logical one (digital receive
interface) or a pulse (analog receive interface) with an amplitude more than Q dB
(defined by LIM1.RIL(2:0)) of the nominal pulse. The value in the 8-bit register PCR
defines the number of pulses (1 to 255) to clear the LOS alarm.
If a loss-of-signal condition is detected in long-haul mode, the data stream can optionally
be cleared automatically to avoid bit errors before LOS is indicated. The selection is
done by LIM1.CLOS = 1.
4.1.9
Receive Jitter Attenuator (E1)
The receive jitter attenuator is placed in the receive path. The working clock is an
internally generated high frequency clock based on the clock provided on pin MCLK. The
jitter attenuator meets the requirements of ITU-T I.431, G. 736 to 739, G.823 and ETSI
TBR12/13.
The internal PLL circuitry DCO-R generates a "jitter-free" output clock which is directly
dependent on the phase difference of the incoming clock and the jitter attenuated
clock.The receive jitter attenuator can be synchronized either on the extracted receive
clock RCLK or on a 2.048-MHz/8-kHz clock provided on pin SYNC (8 kHz in master
mode only). The received data is written into the receive elastic buffer with RCLK and
are read out with the de-jittered clock sourced by DCO-R. The jitter attenuated clock can
be output on pins RCLK, CLK1 or SCLKR. Optionally an 8-kHz clock is provided on pin
SEC⁄FSC.
The DCO-R circuitry attenuates the incoming jittered clock starting at 2-Hz jitter
frequency with 20 dB per decade fall-off. Wander with a jitter frequency below 2 Hz is
passed unattenuated. The intrinsic jitter in the absence of any input jitter is < 0.02 UI.
For some applications it might be useful starting of jitter attenuation at lower frequencies.
Therefore the corner frequency is switchable by the factor of ten down to 0.2 Hz
(LIM2.SCF).
The DCO-R circuitry is automatically centered to the nominal bit rate if the reference
clock on pin SYNC/RCLK is missed for 2, 3 or 4 of the 2.048-MHz clock periods. This
center function of DCO-R can be disabled (CMR2.DCF = 1) in order to accept a gapped
reference clock. In analog line interface mode RCLK is always running. Only in digital
line interface mode with single-rail data a gapped clock can occur.
The receive jitter attenuator works in two different modes:
Data Sheet
66
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
• Slave mode
In slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the recovered route
clock. In case of LOS the DCO-R switches automatically to Master mode. If bit
CMR1.DCS is set automatic switching from RCLK to SYNC is disabled.
• Master mode
In master mode (LIM0.MAS = 1) the jitter attenuator is in free running mode if no clock
is supplied on pin SYNC. If an external clock on the SYNC input is applied, the DCO-R
synchronizes to this input. The external frequency can be 2.048 MHz (IPC.SSYF = 0)
or 8.0 kHz (IPC.SSYF = 1).
The following table shows the clock modes with the corresponding synchronization
sources.
Table 13
System Clocking (E1)
Mode
Internal
SYNC
LOS Active Input
System Clocks generated by DCO-R
Master
independent Fixed to
VDD
DCO-R centered, if CMR2.DCF = 0.
(CMR2.DCF should not be set)
Master
independent 2.048
MHz
Synchronized to SYNC input (external 2.048
MHz, IPC.SSYF = 0)
Master
independent 8.0 kHz
Synchronized to SYNC input (external 8.0 kHz,
IPC.SSYF = 1, CMR2.DCF = 0)
Slave
no
Fixed to
VDD
Synchronized to line RCLK
Slave
no
2.048
MHz
Synchronized to line RCLK
Slave
yes
Fixed to
VDD
CMR1.DCS = 0:
DCO-R is centered, if CMR2.DCF = 0.
(CMR2.DCF should not be set)
CMR1.DCS = 1:
Synchronized on line RCLK
Slave
yes
2.048
MHz
CMR1.DCS = 0:
Synchronized to SYNC input
(external 2.048 MHz)
CMR1.DCS = 1:
Synchronized on line clock RCLK
The jitter attenuator meets the jitter transfer requirements of the ITU-T I.431 and G.735
to 739 (refer to Figure 17)
Data Sheet
67
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
.
ITD10312
10
dB
ITU G.736 Template
R
FALC
0
Attenuation
-10
-20
-30
-40
-50
-60
1
10
100
1000
10000
Hz 100000
Frequency
Figure 17
Jitter Attenuation Performance (E1)
Also the requirements of ETSI TBR12/13 are satisfied. Insuring adequate margin against
TBR12/13 output jitter limit with 15 UI input at 20 Hz the DCO-R circuitry starts jitter
attenuation at about 2 Hz.
Data Sheet
68
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.1.10
Jitter Tolerance (E1)
The FALC56 receiver’s tolerance to input jitter complies with ITU for CEPT applications.
Figure 18 shows the curves of different input jitter specifications stated below as well as
the FALC56 performance.
1000
PUB 62411
TR-NWT 000499 Cat II
CCITT G.823
ITU-T I.431
FALC®
UI
Jitter Amplitude
100
10
1
0.1
1
10
100
1000
10000
Hz
Jitter Frequency
Figure 18
4.1.11
100000
F0025
Jitter Tolerance (E1)
Output Jitter (E1)
In the absence of any input jitter the FALC56 generates the output jitter, which is
specified in theTable 14 below.
Table 14
Specification
ITU-T I.431
ETSI TBR 12
Data Sheet
Output Jitter (E1)
Measurement Filter Bandwidth
Lower Cutoff
Upper Cutoff
Output Jitter
(UI peak to peak)
20 Hz
100 kHz
< 0.015
700 Hz
100 kHz
< 0.015
40 Hz
100 kHz
< 0.11
69
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.1.12
Framer/Synchronizer (E1)
The following functions are performed:
• Synchronization on pulse frame and multiframe
• Error indication when synchronization is lost. In this case, AIS is sent automatically to
the system side and remote alarm is sent to the remote end if enabled.
• Initiating and controlling of resynchronization after reaching the asynchronous state.
This can be done automatically by the FALC56 or user controlled using the
microprocessor interface.
• Detection of remote alarm indication from the incoming data stream.
• Separation of service bits and data link bits. This information is stored in status
registers.
• Generation of various maskable interrupt statuses of the receiver functions.
• Generation of control signals to synchronize the CRC checker, and the receive elastic
buffer.
If programmed and applicable to the selected multiframe format, CRC checking of the
incoming data stream is done by generating check bits for a CRC submultiframe
according to the CRC4 procedure (refer to ITU-T G.704). These bits are compared with
those check bits that are received during the next CRC submultiframe. If there is at least
one mismatch, the CRC error counter (16 bit) is incremented.
4.1.13
Receive Elastic Buffer (E1)
The received bit stream is stored in the receive elastic buffer. The memory is organized
as a two-frame elastic buffer with a maximum size of 64 × 8 bit. The size of the elastic
buffer can be configured independently for the receive and transmit direction.
Programming of the receive buffer size is done by SIC1.RBS1/0:
• RBS1/0 = 00: two frame buffer or 512 bits
Maximum of wander amplitude (peak-to-peak): 190 UI (1 UI = 488 ns)
average delay after performing a slip: 1 frame or 256 bits
• RBS1/0 = 01: one frame buffer or 256 bits
Maximum of wander amplitude: 100 UI
average delay after performing a slip: 128 bits, (SYPR = output)
• RBS1/0 = 10: short buffer or 96 bits
Maximum of wander amplitude: 38 UI
average delay after performing a slip: 48 bits, (SYPR = output)
• RBS1/0 = 11: Bypass of the receive elastic buffer
The functions are:
• Clock adaption between system clock (SCLKR) and internally generated route clock
(RCLK).
• Compensation of input wander and jitter.
Data Sheet
70
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
• Frame alignment between system frame and receive route frame
• Reporting and controlling of slips
Controlled by special signals generated by the receiver, the unipolar bit stream is
converted into bit-parallel data which is circularly written to the elastic buffer using
internally generated receive route clock (RCLK).
Reading of stored data is controlled by the system clock sourced by SCLKR or by the
receive jitter attenuator and the synchronization pulse (SYPR) together with the
programmed offset values for the receive time slot/clock slot counters. After conversion
into a serial data stream, the data is given out on port RDO. If the receive buffer is
bypassed programming of the time slot offset is disabled and data is clocked off with
RCLK instead of SCLKR.
In one frame or short buffer mode the delay through the receive buffer is reduced to an
average delay of 128 or 46 bits. In bypass mode the time slot assigner is disabled. In this
case SYPR programmed as input is ignored. Slips are performed in all buffer modes
except the bypass mode. After a slip is detected the read pointer is adjusted to one half
of the current buffer size.
The following table gives an overview of the receive buffer operating mode.
I
Table 15
Receive Buffer Operating Modes (E1)
Buffer Size
(SIC1.RBS1/0)
TS Offset programming
(RC1/0) + SYPR = input
Slip performance
bypass1)
disabled
recommended:
SYPR = output
no
short buffer
not recommended,
recommended:
SYPR = output
yes
1 frame
not recommended,
recommended:
SYPR = output
yes
2 frames
enabled
yes
1)
In bypass mode the clock provided on pin SCLKR is ignored. Clocking is done with RCLK.
In single frame mode (SIC1.RBS), values of receive time slot offset (RC1/0) have to be
specified great enough to prevent too great approach of frame begin of line side and
frame begin of system side.
Figure 19 gives an idea of operation of the receive elastic buffer:
A slip condition is detected when the write pointer (W) and the read pointer (R) of the
memory are nearly coincident, i.e. the read pointer is within the slip limits (S +, S –). If a
Data Sheet
71
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
slip condition is detected, a negative slip (one frame or one half of the current buffer size
is skipped) or a positive slip (one frame or one half of the current buffer size is read out
twice) is performed at the system interface, depending on the difference between RCLK
and the current working clock of the receive backplane interface. I.e. on the position of
pointer R and W within the memory. A positive/negative slip is indicated in the interrupt
status bits ISR3.RSP and ISR3.RSN.
Frame 2 Time Slots
R’
R
Slip
S-
S+
W
Frame 1 Time Slots
Moment of Slip Detection
W : Write Pointer (Route Clock controlled)
R : Read Pointer (System Clock controlled)
S+, S- : Limits for Slip Detection (mode dependent)
ITD10952
Figure 19
Data Sheet
The Receive Elastic Buffer as Circularly Organized Memory
72
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.1.14
Receive Signaling Controller (E1)
The signaling controller can be programmed to operate in various signaling modes. The
FALC56 performs the following signaling and data link methods.
4.1.14.1 HDLC or LAPD access
The FALC56 offers three independent HDLC channels. All of them provide the following
features:
• 64 byte receive FIFO for each channel
• 64 byte transmit FIFO for each channel
• transmission in one of 31 time slots
(time slot number programmable for each channel individually)
• transmission in even frames only, odd frames only or both
(programmable for each channel individually)
• bit positions to be used in selected time slots are maskable
(any bit position can be enabled for each channel individually)
• HDLC or transparent mode
• flag detection
• CRC checking
• bit-stuffing
• flexible address recognition (1 byte, 2 bytes)
• C/R-bit processing (according to LAPD protocol)
In addition to this, HDLC channel 1 provides:
•
•
•
•
•
SS7 support
BOM (bit oriented message) support
use of time slot 0 (up to 32 time slots)
use of Sa-bits
flexibility to insert and extract data during certain time slots, any combination of time
slots can be programmed independently for the receive and transmit direction
In case of common channel signaling the signaling procedure HDLC/SDLC or LAPD
according to Q.921 is supported. The signaling controller of the FALC56 performs the
flag detection, CRC checking, address comparison and zero-bit removing. The received
data flow and the address recognition features can be performed in very flexible way, to
satisfy almost any practical requirements. Depending on the selected address mode, the
FALC56 performs a 1 or 2-byte address recognition. If a 2-byte address field is selected,
the high address byte is compared with the fixed value FEH or FCH (group address) as
well as with two individually programmable values in RAH1 and RAH2 registers.
According to the ISDN LAPD protocol, bit 1 of the high byte address is interpreted as
command/response bit (C/R) and is excluded from the address comparison. Buffering of
receive data is done in a 64 byte deep RFIFO.
Data Sheet
73
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
In signaling controller transparent mode, fully transparent data reception without HDLC
framing is performed, i.e. without flag recognition, CRC checking or bit stuffing. This
allows user specific protocol variations.
4.1.14.2 Support of Signaling System #7
The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is
described in ITU-Q.703. The following description assumes, that the reader is familiar
with the SS7 protocol definition.
SS7 support must be activated by setting the MODE register. The SS7 protocol is
supported by the following hardware features in receive mode:
•
•
•
•
•
all Signaling Units (SU) are stored in the receive FIFO (RFIFO)
detecting of flags from the incoming data stream
bit stuffing (zero deletion)
checking of seven or more consecutive ones in the receive data stream
checking if the received Signaling Unit is a multiple of eight bits and at least six octets
including the opening flag
• calculation of the CRC16 checksum:
In receive direction the calculated checksum is compared to the received one; errors
are reported in register RSIS.
• checking if the signal information field of a received signaling unit consists of more
than 272 octets, in this case the current signaling unit is discarded.
In order to reduce the microprocessor load, fill In signaling units (FISUs) are processed
automatically. By examining the length indicator of a received signal unit the FALC56
decides whether a FISU has been received. Consecutively received FISUs are
compared and optionally not stored in the receive FIFO (RFIFO, 2×32 bytes), if the
contents is equal to the previous one. The same applies to link status signaling units, if
bit CCR5.CSF is set. The different types of signaling units as message signaling unit
(MSU), link status signaling unit (LSSU) and fill in signaling units (FISU) are indicated in
the RSIS register, which is automatically added to the RFIFO with each received
signaling unit. The complete signaling unit except start and end flags is stored in the
receive FIFO. The functions of bits CCR1.RCRC and CCR1.RADD are still valid in SS7
mode. Errored signaling units are handled automatically according to ITU-T Q.703 as
shown in Figure 20. SU counter (su) and errored SU counter (Cs) are reset by setting
CMDR2.RSUC. The error threshold T can be selected to be 64 (default) or 32 by setting/
clearing bit CCR5.SUET. If the defined error limit is exceeded, an interrupt (ISR1.SUEX)
is generated, if not masked by IMR1.SUEX = 1.
Note: If SUEX is caused by an aborted/invalid frame, the interrupt will be issued
regularly until a valid frame is received (e.g. a FISU).
Data Sheet
74
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Idle
Reset Counter values
Cs := 0
su := 0
[CMDR2.RSUC = 1]
in service
N
SU in error?
Y
Cs := Cs + 1
su := su + 1
Cs = T ?
su := su + 1
N
N
Y
su = 256 ?
Y
Link failure
[ISR1.SUEX = 1]
su := 0
Idle
Cs = 0 ?
Y
N
Notes:
su: signaling units counter
Cs: errored signaling units
counter
T: error threshold (64 or 32),
selectable by CCR5.SUET
Figure 20
Data Sheet
Cs := Cs -1
in service
F0071
Automatic Handling of Errored Signaling Units
75
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.1.14.3 Sa-Bit Access (E1)
The FALC56 supports the Sa-bit signaling of time slot 0 of every other frame as follows:
• the access through register RSW
• the access through registers RSA(8:4), capable of storing the information for a
complete multiframe
• the access through the 64 byte deep receive FIFO of the signaling controller of HDLC
channel 1. This Sa-bit access gives the opportunity to receive a transparent bit stream
as well as HDLC frames where the signaling controller automatically processes the
HDLC protocol. Any combination of Sa-bits which shall be extracted and stored in the
RFIFO is selected by XC0.SA(8:4). The access to the RFIFO is supported by
ISR0.RME/RPF.
4.1.14.4 Channel Associated Signaling CAS (E1, serial mode)
The signaling information is carried in time slot 16 (TS16). The signaling controller
samples the bit stream either on the receive line side or if external signaling is enabled
on the receive system side. External signaling is enabled by selecting the RSIG pin
function in registers PC(4:1) and setting XSP.CASEN = 1.
Optionally the complete CAS multiframe can be transmitted on pin RSIG. The signaling
data is clocked with the working clock of the receive highway (SCLKR) together with the
receive synchronization pulse (SYPR). Data on RSIG is transmitted in the last 4 bits per
time slot and is aligned to the data on RDO. The first 4 bits per time slot can be optionally
fixed high or low (SIC2.SSF), except for time slot 0 and 16 (bit 1 to 4 are always "0000"
in TS16). In time slot 0 the FAS/NFAS word is transmitted, in time slot 16 the CAS
multiframe pattern "0000XYXX". Data on RSIG is only valid if the freeze signaling status
is inactive. With FMR1.SAIS an all-ones data stream can be transmitted on RDO and
RSIG.
The signaling procedure is done as it is described in ITU-T G.704 and G.732.
The main functions are:
• Synchronization to a CAS multiframe
• Detection of AIS and remote alarm in CAS multiframes
• Separation of CAS service bits X1 to X3
Updating of the received signaling information is controlled by the freeze signaling
status. The freeze signaling status is automatically activated if a loss-of-signal
(FRS0.LOS = 1), or a loss of CAS multiframe alignment (FRS1.TSL16LFA = 1) or a
receive slip occurs. The current freeze status is output on port FREEZE (RP(A:D)) and
indicated by register SIS.SFS. Optionally automatic freeze signaling can be disabled by
setting bit SIC3.DAF.
After CAS resynchronization an interrupt is generated. Because at this time the signaling
is still frozen, CAS data is not valid yet. Readout of CAS data has to be delayed until the
next CAS multiframe is received.
Data Sheet
76
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Because the CAS controller is working on the PCM highway side of the receive buffer,
slips disturb the CAS data.
125 µs
SYPR
SCLKR
T
TS31
TS0
TS1
TS16
TS31
RDO
4 56 7
FAS/NFAS
0 12 34 5 67
0 12 34 5 67
01 2 34 5 67
RSIG
ABCD
FAS/NFAS
ABCD
0 0 0 0XYXX
A BCD
T
FAS
NFAS
ABCD
0000XYXX
Figure 21
= Time slot offset (RC0, RC1)
= Frame alignment signal
= TS0 not containing FAS
= Signaling bits for time slots 1...15 and 17...31 of CAS multiframe
= CAS multiframe alignment signal in TS16
F0133
2.048 MHz Receive Signaling Highway (E1)
4.1.14.5 Channel Associated Signaling CAS (E1, µP access mode)
The signaling information is carried in time slot 16 (TS16). Receive data is stored in
registers RS(16:1) aligned to the CAS multiframe boundary. The signaling controller
samples the bit stream either on the receive line side or if external signaling is enabled
on the receive system side.
The signaling procedure is done as it is described in ITU-T G.704 and G.732.
The main functions are:
•
•
•
•
Synchronization to a CAS multiframe
Detection of AIS and remote alarm in CAS multiframes
Separation of CAS service bits X1 to X3
Storing of received signaling data in registers RS(16:1) with last look capability
Updating of the received signaling information is controlled by the freeze signaling
status. The freeze signaling status is automatically activated if a loss-of-signal
(FRS0.LOS = 1), or a loss of CAS multiframe alignment (FRS1.TSL16LFA = 1) or a
receive slip occurs. The current freeze status is output on port FREEZE (RP(A:D)) and
indicated by register SIS.SFS. Optionally automatic freeze signaling can be disabled by
setting bit SIC3.DAF. If SIS.SFS is active, updating of the registers RS(16:1) is disabled.
To relieve the µP load from always reading the complete RS(16:1) buffer every 2 ms the
FALC56 notifies the µP through interrupt ISR0.CASC only when signaling changes from
Data Sheet
77
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
one multiframe to the next. Additionally the FALC56 generates a receive signaling data
change pointer (RSP1/2) which directly points to the updated RS(16:1) register.
Because the CAS controller is working on the PCM highway side of the receive buffer,
slips disturb the CAS data.
Data Sheet
78
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.2
Framer Operating Modes (E1)
4.2.1
General
Bit: FMR1.PMOD = 0
PCM line bit rate
Single frame length
Framing frequency
HDLC controller
Organization
:
:
:
:
:
2.048 Mbit/s
256 bit, No. 1…256
8 kHz
nx64 kbit/s, n = 1 to 32 or n×4 kbit/s, n = 1 to 5
32 time slots, No. 0…31
with 8 bits each, No. 1…8
The operating mode of the FALC56 is selected by programming the carrier data rate and
characteristics, line code, multiframe structure, and signaling scheme.
The FALC56 implements all of the standard framing structures for E1 or PCM 30 (CEPT,
2.048 Mbit/s) carriers. The internal HDLC or CAS controller supports all signaling
procedures including signaling frame synchronization/synthesis and signaling alarm
detection in all framing formats. The time slot assignment from the PCM line to the
system highway and vice versa is performed without any changes of numbering (TS0 ↔
TS0, …, TS31 ↔ TS31).
Summary of E1 Framing Modes
•
•
•
•
•
•
Doubleframe format according to ITU-T G. 704
Multiframe format according to ITU-T G. 704
CRC4 processing according to ITU-T G. 706
Multiframe format with CRC4 to non CRC4 interworking according to ITU-T G. 706
Multiframe format with modified CRC4 to non CRC4 interworking
Multiframe format with CRC4 performance monitoring
After reset, the FALC56 is switched into doubleframe format automatically. Switching
between the framing formats is done by programming bits FMR2.RFS1/0 and
FMR3.EXTIW for the receiver and FMR1.XFS for the transmitter.
Data Sheet
79
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.2.2
Doubleframe Format (E1)
The framing structure is defined by the contents of time slot 0 (refer to Table 16).
Table 16
Allocation of Bits 1 to 8 of Time Slot 0 (E1)
Bit
AlternateNumber
Frames
Frame Containing the
Frame Alignment Signal
1
2
3
4
5
6
7
8
Si
0
0
1
1
0
1
1
Note 1)
Frame Alignment Signal
Sa5
Sa6
Sa7
Sa8
Frame not Containing the
Frame Alignment Signal Si
or
Note 1)
Service Word
1
A
Sa4
Note 2)
Note 3)
Note 4)
1)
Si-bits: reserved for international use. If not used, these bits should be fixed to "1". Access to received
information trough bits RSW.RSI and RSP.RSIF. Transmission is enabled by bits XSW.XSIS and XSP.XSIF.
2)
Fixed to "1". Used for synchronization.
3)
Remote alarm indication: In undisturbed operation "0"; in alarm condition "1".
4)
Sa-bits: Reserved for national use. If not used, they should be fixed at "1". Access to received information
trough bits RSW.RY0…4. Transmission is enabled by bits XSW.XY0…4. HDLC signaling in bits Sa4 to 8 is
selectable. As a special extension for double frame format, the Sa-bit registers RSA4 to 8/XSA4 to 8 can be
used optionally.
4.2.2.1
Transmit Transparent Modes
In transmit direction, contents of time slot 0 frame alignment signal of the outgoing PCM
frame are normally generated by the FALC56. However, transparency for the complete
time slot 0 can be achieved by selecting the transparent mode XSP.TT0. With the
Transparent Service Word Mask register TSWM the Si-bits, A-bit and the Sa-bits can be
selectively switched through transparently.
Data Sheet
80
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Table 17
Transmit Transparent Mode (Doubleframe E1)
Transmit Transparent Source for
Enabled by
–
XSP.TT0
TSWM.TSIF
TSWM.TSIS
TSWM.TRA
TSWM.TSA(8:4)
Framing
(int. gen.)
via pin XDI1)
(int. gen.)
(int. gen.)
(int. gen.)
(int. gen.)
A-Bit
2)
XSW.XRA
via pin XDI
XSW.XRA
XSW.XRA
via pin XDI
XSW.XRA
Sa-Bits
Si-Bits
XSW.XY0…4
XSW.XSIS, XSP.XSIF
via pin XDI
via pin XDI
via pin XDI
XSW.XSIS, XSP.XSIF
XSW.XSIS, XSP.XSIF
3)
via pin XDI
XSW.XY0…4
XSW.XY0…4
XSW.XY0…4
via pin XDI
1)
pin XDI or XSIG or XFIFO buffer (signaling controller)
2)
Additionally, automatic transmission of the A-bit is selectable.
3)
As a special extension for double frame format, the Sa-bit register can be used optionally.
4.2.2.2
Synchronization Procedure
Synchronization status is reported by bit FRS0.LFA. Framing errors are counted by the
Framing Error Counter (FEC). Asynchronous state is reached after detecting 3 or 4
consecutive incorrect FAS words or 3 or 4 consecutive incorrect service words (bit 2 = 0
in time slot 0 of every other frame not containing the frame alignment word), the selection
is done by bit RC0.ASY4. Additionally, the service word condition can be disabled. When
the framer lost its synchronization an interrupt status bit ISR2.LFA is generated.
In asynchronous state, counting of framing errors and detection of remote alarm is
stopped. AIS is automatically sent to the backplane interface (can be disabled by bit
FMR2.DAIS).
Further on the updating of the registers RSW, RSP, RSA(8:4), RSA6S and RS(16:1) is
halted (remote alarm indication, Sa/Si-Bit access).
The resynchronization procedure starts automatically after reaching the asynchronous
state. Additionally, it can be invoked user controlled by bit FMR0.FRS (force
resynchronization, the FAS word detection is interrupted until the framer is in the
asynchronous state. After that, resynchronization starts automatically).
Synchronous state is established after detecting:
• a correct FAS word in frame n,
• the presence of the correct service word (bit 2 = 1) in frame n + 1,
• a correct FAS word in frame n + 2.
If the service word in frame n + 1 or the FAS word in frame n + 2 or both are not found
searching for the next FAS word starts in frame n + 2 just after the previous frame
alignment signal.
Data Sheet
81
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Reaching the synchronous state causes a frame alignment recovery interrupt status
ISR2.FAR if enabled. Undisturbed operation starts with the beginning of the next
doubleframe.
4.2.2.3
A-Bit Access
If the FALC56 detects a remote alarm indication in the received data stream the interrupt
status bit ISR2.RA is set. With setting of bit XSW.XRA a remote alarm (RAI) is sent to
the far end.
By setting FMR2.AXRA the FALC56 automatically transmit the remote alarm bit = 1 in
the outgoing data stream if the receiver detects a loss of frame alignment FRS0.LFA = 1.
If the receiver is in synchronous state FRS0.LFA = 0 the remote alarm bit is reset.
Note: The A-bit can be processed by the system interface. Setting bit TSWM.TRA
enables transparency for the A-bit in transmit direction (refer to Table 16).
4.2.2.4
Sa-Bit Access
As an extension for access to the Sa-bits through registers RSA(8:4)/XSA(8:4) an option
is implemented to allow the usage of internal Sa-bit registers RSA(8:4)/XSA(8:4) in
doubleframe format.
This function is enabled by setting FMR1.ENSA = 1 for the transmitter and
FMR1.RFS(1:0) = 01 for the receiver. In this case the FALC56 internally works with a 16frame structure but no CRC multiframe alignment/generation is performed.
Data Sheet
82
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.2.3
CRC-Multiframe (E1)
The multiframe structure shown in Table 18 is enabled by setting bit: FMR2.RFS1/0 for
the receiver and FMR1.XFS for the transmitter.
Multiframe
Frame alignment
Multiframe alignment
CRC bits
CRC block size
CRC procedure
Table 18
:
:
:
:
:
:
2 submultiframes = 2 × 8 frames
refer to section Doubleframe Format
bit 1 of frames 1, 3, 5, 7, 9, 11 with the pattern "001011"
bit 1 of frames 0, 2, 4, 6, 8, 10, 12, 14
2048 bit (length of a submultiframe)
CRC4, according to ITU-T G.704 and G.706
CRC-Multiframe Structure (E1)
SubMultiframe
Multiframe I
II
Frame
Number
Bits 1 to 8 of the Frame
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
C1
0
C2
0
C3
1
C4
0
0
1
0
1
0
1
0
1
0
A
0
A
0
A
0
A
1
Sa4
1
Sa4
1
Sa4
1
Sa4
1
Sa5
1
Sa5
1
Sa5
1
Sa5
0
Sa61
0
Sa62
0
Sa63
0
Sa64
1
Sa7
1
Sa7
1
Sa7
1
Sa7
1
Sa8
1
Sa8
1
Sa8
1
Sa8
8
9
10
11
12
13
14
15
C1
1
C2
1
C3
E*
C4
E*
0
1
0
1
0
1
0
1
0
A
0
A
0
A
0
A
1
Sa4
1
Sa4
1
Sa4
1
Sa4
1
Sa5
1
Sa5
1
Sa5
1
Sa5
0
Sa61
0
Sa62
0
Sa63
0
Sa64
1
Sa7
1
Sa7
1
Sa7
1
Sa7
1
Sa8
1
Sa8
1
Sa8
1
Sa8
E:
Spare bits for international use. Access to received information through bits
RSP.RS13 and RSP.RS15. Transmission is enabled by bits XSP.XS13 and
XSP.XS15. Additionally, automatic transmission for submultiframe error
indication is selectable.
Sa:
Spare bits for national use. Additionally, Sa-bit access through registers
RSA4…8 and XSA4…8 is provided. HDLC-signaling in bits Sa4 to Sa8 is
selectable.
C1 … C4:
Cyclic redundancy check bits.
A:
Remote alarm indication. Additionally, automatic transmission of the A-bit is
selectable.
Data Sheet
83
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
For transmit direction, contents of time slot 0 are additionally determined by the selected
transparent mode.
Table 19
Transmit Transparent Mode (CRC Multiframe E1)
Transmit Transparent Source for
enabled by
Framing +
CRC
A-Bit
Sa-Bits
E-Bits
–
XSP.TT0
TSWM.TSIF
TSWM.TSIS
TSWM.TRA
TSWM.TSA(8:4)
(int. gen.)
via pin XDI1)
via pin XDI
via pin XDI
(int. gen.)
(int. gen.)
XSW.XRA2)
via pin XDI
XSW.XRA1)
XSW.XRA1)
via pin XDI
XSW.XRA1)
XSW.XY0 … 43)
via pin XDI
XSW.XY0 … 42)
XSW.XY0 … 42)
XSW.XY0 … 42)
via pin XDI
XSP.XS13/XS154)
via pin XDI
(int. generated)
via pin XDI
XSP.XS13/XS153)
XSP.XS13/XS153)
1)
pin XDI or XSIG or XFIFO buffer (signaling controller)
2)
Automatic transmission of the A-bit is selectable
3)
The Sa-bit register XSA(8:4) can be used optionally
4)
Additionally, automatic transmission of submultiframe error indication is selectable
The CRC procedure is automatically invoked when the multiframe structure is enabled.
CRC errors in the received data stream are counted by the 16-bit CRC Error Counter
CEC (one error per submultiframe, maximum).
Additionally a CRC4 error interrupt status ISR0.CRC4 is generated if enabled by
IMR0.CRC4.
All CRC bits of one outgoing submultiframe are automatically inverted in case a CRC
error is flagged for the previous received submultiframe. This function is enabled by bit
RC0.CRCI. Setting of bit RC0.XCRCI inverts the CRC bits before transmission to the
distant end. The function of RC0.XCRCI and RC0.CRCI are logically ored.
4.2.3.1
Synchronization Procedure
Multiframe alignment is assumed to have been lost if doubleframe alignment has been
lost (flagged on status bit FRS0.LFA). The rising edge of this bit causes an interrupt.
The multiframe resynchronization procedure starts when Doubleframe alignment has
been regained which is indicated by an interrupt status bit ISR2.FAR. For Doubleframe
synchronization refer to section Doubleframe Format. It is also be invoked by the user
by setting
• bit FMR0.FRS for complete doubleframe and multiframe resynchronization
• bit FMR1.MFCS for multiframe resynchronization only.
The CRC checking mechanism is enabled after the first correct multiframe pattern has
been found. However, CRC errors are not counted in asynchronous state.
Data Sheet
84
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
In doubleframe asynchronous state, counting of framing errors, CRC4 bit errors and
detection of remote alarm is stopped. AIS is automatically sent to the backplane interface
(can be disabled by bit FMR2.DAIS). Further on the updating of the registers RSW, RSP,
RSA(8:4), RSA6S and RS(16:1) is halted (remote alarm indication, Sa/Si-bit access).
The multiframe synchronous state is established after detecting two correct multiframe
alignment signals at an interval of n × 2 ms (n = 1, 2, 3 …). The loss of multiframe
alignment flag FRS0.LMFA is reset. Additionally an interrupt status multiframe alignment
recovery bit ISR2.MFAR is generated with the falling edge of bit FRS0.LMFA.
4.2.3.2
Automatic Force Resynchronization (E1)
In addition, a search for Doubleframe alignment is automatically initiated if two
multiframe pattern with a distance of n × 2 ms have not been found within a time interval
of 8 ms after doubleframe alignment has been regained (bit FMR1.AFR). A new search
for frame alignment is started just after the previous frame alignment signal.
4.2.3.3
Floating Multiframe Alignment Window (E1)
After reaching doubleframe synchronization a 8 ms timer is started. If a multiframe
alignment signal is found during the 8 ms time interval the internal timer is reset to
remaining 6 ms in order to find the next multiframe signal within this time. If the
multiframe signal is not found for a second time, the interrupt status bit ISR0.T8MS is
set. This interrupt usually occurs every 8 ms until multiframe synchronization is
achieved.
4.2.3.4
CRC4 Performance Monitoring (E1)
In the synchronous state checking of multiframe pattern is disabled. However, with bit
FMR2.ALMF an automatic multiframe resynchronization mode can be activated. If 915
out of 1000 errored CRC submultiframes are found then a false frame alignment is
assumed and a search for doubleframe and multiframe pattern is initiated. The new
search for frame alignment is started just after the previous basic frame alignment signal.
The internal CRC4 resynchronization counter is reset when the multiframe
synchronization has been regained.
4.2.3.5
Modified CRC4 Multiframe Alignment Algorithm (E1)
The modified CRC4 multiframe alignment algorithm allows an automatic interworking
between framers with and without a CRC4 capability. The interworking is realized as it
is described in ITU-T G.706 Appendix B.
If doubleframe synchronization is consistently present but CRC4 multiframe alignment is
not achieved within 400 ms it is assumed that the distant end is initialized to doubleframe
format. The CRC4/non-CRC4 interworking is enabled by FMR2.RFS1/0 = 11 and is
activated only if the receiver has lost its synchronization. If doubleframe alignment (basic
Data Sheet
85
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
frame alignment) is established, a 400 ms timer and searching for multiframe alignment
are started. A research for basic frame alignment is initiated if the CRC4 multiframe
synchronization cannot be achieved within 8 ms and is started just after the previous
frame alignment signal. The research of the basic frame alignment is done in parallel and
is independent of the synchronization procedure of the primary basic frame alignment
signal. During the parallel search all receiver functions are based on the primary frame
alignment signal, like framing errors, Sa-, Si-, A-bits, …). All subsequent multiframe
searches are associated with each basic framing sequence found during the parallel
search.
If the CRC4 multiframe alignment sequence was not found within the time interval of
400 ms, the receiver is switched into a non-CRC4 mode indicated by setting the bit
FRS0.NMF (No Multiframing Found) and ISR2.T400MS. In this mode checking of CRC
bits is disabled and the received E-bits are forced to low. The transmitter framing format
is not changed. Even if multiple basic FAS resynchronizations have been established
during the parallel search, the receiver is maintained to the initially determined primary
frame alignment signal location.
However, if the CRC4-multiframe alignment can be achieved within the 400 ms time
interval assuming a CRC4-to-CRC4 interworking, then the basic frame alignment
sequence associated to the CRC4 multiframe alignment signal is chosen. If necessary,
the primary frame alignment signal location is adjusted according to the multiframe
alignment signal. The CRC4 performance monitoring is started if enabled by
FMR2.ALMF and the received E-bits are processed in accordance to ITU-T G.704.
Switching into the doubleframe format (non-CRC4) mode after 400 ms can be disabled
by setting of FMR3.EXTIW. In this mode the FALC56 continues to search for
multiframing. In the interworking mode setting of bit FMR1.AFR is not allowed.
4.2.3.6
A-Bit Access (E1)
If the FALC56 detects a remote alarm indication (bit 2 in TS0 not containing the FAS
word) in the received data stream the interrupt status bit ISR2.RA is set. With the
deactivation of the remote alarm the interrupt status bit ISR2.RAR is generated.
By setting FMR2.AXRA the FALC56 automatically transmits the remote alarm bit = 1 in
the outgoing data stream if the receiver detects a loss of frame alignment
(FRS0.LFA = 1). If the receiver is in synchronous state (FRS0.LFA = 0), the remote
alarm bit is reset in the outgoing data stream.
Additionally, if bit FMR3.EXTIW is set and the multiframe synchronous state cannot be
achieved within 400 ms after finding the primary basic framing, the A-bit is transmitted
active high to the remote end until the multiframing is found.
Note: The A-bit can be processed by the system interface. Setting bit TSWM.TRA
enables transparency for the A-bit in transmit direction (refer to Table 18).
Data Sheet
86
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.2.3.7
Sa-Bit Access (E1)
Due to signaling procedures using the five Sa-bits (Sa4…Sa8) of every other frame of the
CRC multiframe structure, three possibilities of access by the microprocessor are
implemented.
• The standard procedure allows reading/writing the Sa-bit registers RSW, XSW without
further support. The Sa-bit information is updated every other frame.
• The advanced procedure, enabled by bit FMR1.ENSA, allows reading/writing the Sabit registers RSA4…8, XSA4…8.
A transmit or receive multiframe begin interrupt (ISR0.RMB or ISR1.XMB) is provided.
Registers RSA(8:4) contains the service word information of the previously received
CRC-multiframe or 8 doubleframes (bit slots 4 to 8 of every service word). These
registers are updated with every multiframe begin interrupt ISR0.RMB.
With the transmit multiframe begin an interrupt ISR1.XMB is generated and the contents
of the registers XSA(8:4) is copied into shadow registers. The contents is subsequently
sent out in the service words of the next outgoing CRC multiframe (or every
doubleframe) if none of the time slot 0 transparent modes is enabled. The transmit
multiframe begin interrupt XMB request that these registers issue should be serviced. If
requests for new information are ignored, the current contents is repeated.
• The extended access through the receive and transmit FIFOs of the signaling
controller. In this mode it is possible to transmit/receive a HDLC frame or a transparent
bit stream in any combination of the Sa-bits. Enabling is done by setting of bit
CCR1.EITS and the corresponding bits XC0.SA8E to SA4E/TSWM.TSA8 to TSA4
and resetting of registers TTR(4:1), RTR(4:1) and FMR1.ENSA. The access to and
from the FIFOs is supported by ISR0.RME, RPF and ISR1.XPR, ALS.
Sa6-Bit Detection according to ETS 300233
Four consecutive received Sa6-bits are checked for the combinations defined by
ETS 300233. The FALC56 detects the following fixed Sa6-bit combinations: SA61,
SA62, SA63, SA64 = 1000, 1010, 1100, 1110, 1111. All other possible 4-bit
combinations are grouped to status “X”.
A valid Sa6-bit combination must occur three times in a row. The corresponding status
bit in register RSA6S is set. Register RSA6S is of type “clear on read”. Any status change
of the Sa6-bit combinations causes an interrupt (ISR0.SA6SC).
During the basic frame asynchronous state update of register RSA6S and interrupt
status ISR0.SA6SC is disabled. In multiframe format the detection of the Sa6-bit
combinations can be done either synchronously or asynchronously to the submultiframe
(FMR3.SA6SY). In synchronous detection mode updating of register RSA6S is done in
the multiframe synchronous state (FRS0.LMFA = 0). In asynchronous detection mode
updating is independent of the multiframe synchronous state.
Data Sheet
87
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Sa6-Bit Error Indication Counters
The Sa6-bit error indication counter CRC2L/H (16 bits) counts the received Sa6-bit
sequence 0001 or 0011 in every CRC submultiframe. In the primary rate access digital
section this counter option gives information about CRC errors reported from the TE by
the Sa6 bit. Incrementing is only possible in the multiframe synchronous state. The Sa6bit error indication counter CRC3L/H (16 bits) counts the received Sa6-bit sequence
0010 or 0011 in every CRC submultiframe. In the primary rate access digital section this
counter option gives information about CRC errors detected at T-reference point and
reporting them by the Sa6-bit. Incrementing is only possible in the multiframe
synchronous state.
4.2.3.8
E-Bit Access (E1)
Due to signaling requirements, the E-bits of frame 13 and frame 15 of the CRC
multiframe can be used to indicate received errored submultiframes:
Submultiframe I statusE-bit located in frame 13
Submultiframe II statusE-bit located in frame 15
no CRC error: E = 1; CRC error:E = 0
Standard Procedure
After reading the submultiframe error indication RSP.SI1 and RSP.SI2, the
microprocessor has to update the contents of register XSP (XS13, XS15). Access to
these registers has to be synchronized on transmit or receive multiframe begin interrupts
(ISR0.RMB or ISR1.XMB).
Automatic Mode
In the multiframe synchronous state the E-bits are processed according to ITU-T G.704
independently of bit XSP.EBP (E-bit polarity selection).
By setting bit XSP.AXS status information of received submultiframes is automatically
inserted in the E-bit position of the outgoing CRC multiframe without any further
interventions of the microprocessor.
In the doubleframe and multiframe asynchronous state the E-bits are set or cleared,
depending on the setting of bit XSP.EBP.
Submultiframe Error Indication Counter
The EBC (E-Bit) counter EBCL/H (16 bits) counts zeros in the E-bit position of frame 13
and 15 of every received CRC multiframe. This counter option gives information about
the outgoing transmit PCM line if the E-bits are used by the remote end for submultiframe
error indication. Incrementing is only possible in the multiframe synchronous state.
Data Sheet
88
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Note: E-bits can be processed by the system interface. Setting bit TSWM.TSIS enables
transparency for E-bits in transmit direction (refer to Table 18).
OUT of Primary BFA:
Inhibit Incoming CRC-4 Performance Monitoring
Reset all Timers
Set FRS0.LFA/LMFA/NMF = 110
No
Primary
BFA Search ?
Yes
IN Primary BFA:
Start 400 ms Timer
Enable Primary BFA Loss Checking Process
Reset Internal Frame Alignment Status
(FRS0.LFA = 0)
CRC-4 MFA Search
Start 8 ms Timer
Yes
No
Parallel
BFA Search
Good ?
No
Yes
Can CRC-4
MFA be found
in 8 ms ?
No
400 ms
Timer
Elapsed ?
Yes
Assume CRC-4 to CRC-4 Interworking:
Confirm Primary BFA Associated with CRC-4 MFA
Adjust Primary BFA if Necessary
Reset Internal Multiframe Alignment Status
(FRS0.LMFA = 0)
Assume CRC-4 to non CRC-4 Interworking:
Confirm Primary BFA
Set Internal 400 ms Timer Expiration Status Bit
(FRS0.NMF = 1)
Start CRC-4 Performance Monitoring
Yes
CRC-4
Error Count <_ 915
or LFA ?
No
Continue CRC-4 Performance Monitoring
ITD10310
Figure 22
CRC4 Multiframe Alignment Recovery Algorithms (E1)
Data Sheet
89
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.3
Additional Receive Framer Functions (E1)
4.3.1
Error Performance Monitoring and Alarm Handling
Alarm Indication Signal: Detection and recovery is flagged by bit FRS0.AIS and
ISR2.AIS. Transmission is enabled by bit FMR1.XAIS.
Loss-Of-Signal: Detection and recovery is flagged by bit FRS0.LOS and ISR2.LOS.
Remote Alarm Indication: Detection and release is flagged by bit FRS0.RRA, RSW.RRA
and ISR2.RA/RAR. Transmission is enabled by bit XSW.XRA.
AIS in time slot 16: Detection and release is flagged by bit FRS1.TS16AIS and
ISR3.AIS16. Transmission is enabled by writing all ones in registers XS(16:1).
LOS in time slot 16: Detection and release is flagged by bit FRS1.TS16LOS.
Transmission is enabled by writing all zeros in registers XS(16:1).
Remote Alarm in time slot 16: Detection and release is flagged by bit FRS1.TS16RA and
ISR3.RA16. Transmission is enabled by bit XS1.2.
Transmit Line Shorted: Detection and release is flagged by bit FRS1.XLS and
ISR1.XLSC.
Transmit Ones-Density: Detection and release is flagged by bit FRS1.XLO and
ISR1.XLSC.
Table 20
Summary of Alarm Detection and Release (E1)
Alarm
Detection Condition
Clear Condition
Loss-Of-Signal
(LOS)
no transitions (logical
zeros) in a programmable
time interval of 16 to 4096
consecutive pulse periods.
Programmable receive
input signal threshold
programmable number of ones (1
to 256) in a programmable time
interval of 16 to 4096 consecutive
pulse periods. A one is a signal
with a level above the
programmed threshold.
Alarm Indication
Signal (AIS)
FMR0.ALM = 0:
less than 3 zeros in
250 µs and loss of frame
alignment declared
FMR0.ALM = 0:
more than 2 zeros in
250 µs
FMR0.ALM = 1:
less than 3 zeros in
each of two consecutive
250-µs periods
Remote Alarm
(RRA)
Data Sheet
bit 3 = 1 in time slot 0 not
containing the FAS word
90
FMR0.ALM = 1:
more than 2 zeros in each of two
500-µs periods
set conditions no longer detected.
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Table 20
Summary of Alarm Detection and Release (E1) (cont’d)
Alarm
Detection Condition
Remote Alarm in
Y-bit = 1 received in CAS
time slot 16 (TS16RA) multiframe alignment word
Clear Condition
Y-bit = 0 received in CAS
multiframe alignment word
Loss-of-Signal in
time slot 16
(TS16LOS)
all zeros for at least 16
receiving a one in
consecutively received time time slot 16
slots 16
Alarm Indication
Signal in time slot 16
(TS16AIS)
time slot 16 containing less time slot 16 containing more than
than 4 zeros in each of two 3 zeros in one CAS multiframe
consecutive CAS
multiframes periods
Transmit Line Short
(XLS)
more than 3 pulse periods
with highly increased
transmit line current on
XL1/2
Transmit OnesDensity
(XLO)
32 consecutive zeros in the Cleared with each transmitted
transmit data stream on
pulse
XL1/2
4.3.2
transmit line current limiter
inactive
Auto Modes
• Automatic remote alarm access
If the receiver has lost its synchronization a remote alarm can be sent automatically,
if enabled by bit FMR2.AXRA to the distant end. The remote alarm bit is set
automatically in the outgoing data stream, if the receiver is in asynchronous state
(FRS0.LFA bit is set). In synchronous state the remote alarm bit is removed.
• Automatic E-bit access
By setting bit XSP.AXS status information of received submultiframes is automatically
inserted at the E-bit position of the outgoing CRC Multiframe without any further
interventions of the microprocessor.
• Automatic AIS to system interface
In asynchronous state the synchronizer enforces an AIS to the receive system
interface automatically. However, received data can be switched through
transparently, if bit FMR2.DAIS is set.
• Automatic clock source switching
In slave mode (LIM0.MAS = 0) the DCO-R synchronizes to the recovered route clock.
In case of loss-of-signal (LOS) the DCO-R switches to Master mode automatically. If
bit CMR1.DCS is set, automatic switching from RCLK to SYNC is disabled.
• Automatic freeze signaling:
Updating of the received signaling information is controlled by the freeze signaling
status. The freeze signaling status is automatically activated if a loss-of-signal or a
Data Sheet
91
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
loss of CAS multiframe alignment or a receive slip occurs. The internal signaling buffer
RS(16:1) is frozen. Optionally automatic freeze signaling is disabled by setting bit
SIC3.DAF.
4.3.3
Error Counter
The FALC56 offers six error counters where each of them has a length of 16 bit. They
record code violations, framing bit errors, CRC4-bit errors and CRC4 error events which
are flagged in the different Sa6-bit combinations or the number of received multiframes
in asynchronous state or the change of frame alignment (COFA). Counting of the
multiframes in the asynchronous state and the COFA parameter is done in a 6/2 bit
counter and is shared with CEC3L/H. Each of the error counters is buffered. Buffer
updating is done in two modes:
• One-second accumulation
• On demand by handshake with writing to the DEC register
In the one-second mode an internal/external one-second timer updates these buffers
and resets the counter to accumulate the error events in the next one-second period.
The error counter cannot overflow. Error events occurring during an error counter reset
are not lost.
4.3.4
Errored Second
The FALC56 supports the error performance monitoring by detecting the following
alarms or error events in the received data:
framing errors, CRC errors, code violations, loss of frame alignment, loss-of-signal,
alarm indication signal, E-bit error, receive and transmit slips.
With a programmable interrupt mask register ESM all these alarms or error events can
generate an errored second interrupt (ISR3.ES) if enabled.
4.3.5
One-Second Timer
Additionally, a one-second timer interrupt can be generated internally to indicate that the
enabled alarm status bits or the error counters have to be checked. The one-second
timer signal is output on port SEC/FSC (GPC1.CSFP1/0). Optionally synchronization to
an external second timer is possible which has to be provided on pin SEC/FSC.
Selecting the external second timer is done with GCR.SES. Refer also to register GPC1
for input/output selection.
4.3.6
In-Band Loop Generation and Detection
The FALC56 generates and detects a framed or unframed in-band loop-up (activate) and
loop-down (deactivate) pattern with bit error rates up to 10-2. Framed or unframed inband loop code is selected by LCR1.FLLB. Replacing transmit data with the in-band loop
codes is done by programming FMR3.XLD/XLU.
Data Sheet
92
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
The FALC56 also offers the ability to generate and detect a flexible in-band loop-up and
loop-down pattern (LCR1.LLBP = 1). The loop-up and loop-down pattern is individually
programmable from 2 to 8 bits in length (LCR1.LAC1/0 and LCR1.LDC1/0).
Programming of loop codes is done in registers LCR2 and LCR3.
Status and interrupt status bits inform the user whether loop-up or loop-down code has
been detected.
4.3.7
Time Slot 0 Transparent Mode
The transparent modes are useful for loop-backs or for routing data unchanged through
the FALC56.
In receive direction, transparency for ternary or dual-/single-rail unipolar data is always
achieved if the receiver is in the synchronous state. In asynchronous state data is
transparently switched through if bit FMR2.DAIS is set. However, correct time slot
assignment cannot be guaranteed due to missing frame alignment between line and
system side.
Setting of bit LOOP.RTM disconnects control of the internal elastic store from the
receiver. The elastic buffer is now in a “free running” mode without any possibility to
update the time slot assignment to a new frame position in case of resynchronization of
the receiver. Together with FMR2.DAIS this function can be used to realize undisturbed
transparent reception.
Transparency in transmit direction can be achieved by activating the time slot 0
transparent mode (bit XSP.TT0 or TSWM.(7:0)). If XSP.TT0 = 1 all internal information
of the FALC56 (framing, CRC, Sa/Si-bit signaling, remote alarm) is ignored. With register
TSWM the Si-bits, A-bit or the Sa-bits can be enabled selectively to send data
transparently from port XDI to the far end. For complete transparency the internal
signaling controller, idle code generation and AIS alarm generation, single channel and
payload loop-back have to be disabled.
Data Sheet
93
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.4
Transmit Path in E1 Mode
4.4.1
Transmitter (E1)
The serial bit stream is processed by the transmitter which has the following functions:
•
•
•
•
•
•
•
Frame/multiframe synthesis of one of the two selectable framing formats
Insertion of service and data link information
AIS generation (Alarm indication signal)
Remote alarm generation
CRC generation and insertion of CRC bits
CRC bits inversion in case of a previously received CRC error
Idle code generation per DS0
The frame/multiframe boundaries of the transmitter can be externally synchronized by
using the SYPX/XMFS pin. Any change of the transmit time slot assignment
subsequently produces a change in the framing bit positions on the line side. This feature
is required if signaling and service bits are routed through the switching network and are
inserted in transmit direction by the system interface.
In loop-timed configuration (LIM2.ELT = 1) disconnecting the control of the transmit
system highway from the transmitter is done by setting XSW.XTM. The transmitter is
now in a free running mode without any possibility to update the multiframe position in
case of changing the transmit time slot assignment. The framing bits are generated
independently of the transmit system interface. For proper operation the transmit elastic
buffer size should be programmed to 2 frames.
The contents of selectable time slots can be overwritten by the pattern defined by
register IDLE. The selection of “idle channels” is done by programming the four-byte
registers ICB1…ICB4.
Data Sheet
94
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.4.2
Transmit Line Interface (E1)
The analog transmitter transforms the unipolar bit stream to ternary (alternate bipolar)
return to zero signals of the appropriate programmable shape. The unipolar data is
provided by the digital transmitter.
R1
XL1
Line
t1
t2
FALC R
R1
XL2
ITS10968
Figure 23
Transmitter Configuration (E1)
Table 21
Recommended Transmitter Configuration Values (E1)
Characteristic Impedance [Ω]
Parameter
R1 (± 1%) [Ω]
t2 : t1
1)
120
75
7.51)
7.51)
1 : 2.4
1 : 2.4
This value refers to an ideal transformer without any parasitics. Any transformer resistance or other parasitic
resistances have to be taken into account when calculating the final value of the output serial resistors.
Similar to the receive line interface three different data types are supported:
• Ternary Signal
Single-rail data is converted into a ternary signal which is output on pins XL1 and XL2.
The HDB3 and AMI line code is employed. Selected by FMR0.XC1/0 and
LIM1.DRS = 0.
• Dual-rail data PCM(+), PCM(–) at multifunction ports XDOP/XDON with 50% or 100%
duty cycle and with programmable polarity. Line coding is done in the same way as in
ternary interface mode. Selected by FMR0.XC1/0 and LIM1.DRS = 1.
• Unipolar data on port XOID is transmitted either in NRZ (Non Return to Zero) with
100% duty cycle or in CMI (Code Mark Inversion or known as 1T2B) Code with or
without (FMR3.CMI) preprocessed HDB3 coding to a fiber-optical interface. Clocking
off data is done with the rising edge of the transmit clock XCLK (2048 kHz) and with
a programmable polarity. Selection is done by FMR0.XC1 = 0 and LIM1.DRS = 1.
Data Sheet
95
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.4.3
Transmit Jitter Attenuator (E1)
The transmit jitter attenuator DCO-X circuitry generates a "jitter-free" transmit clock and
meets the following requirements: ITU-T I.431, G. 703, G. 736 to 739, G.823 and ETSI
TBR12/13. The DCO-X circuitry works internally with the same high frequency clock as
the receive jitter attenuator. It synchronizes either to the working clock of the transmit
backplane interface or the clock provided on pin TCLK or the receive clock RCLK
(remote loop/loop-timed). The DCO-X attenuates the incoming clock jitter starting at
2 Hz with 20 dB per decade fall-off. With the jitter attenuated clock, which is directly
depending on the phase difference of the incoming clock and the jitter attenuated clock,
data is read from the transmit elastic buffer (2 frames) or from the JATT buffer (2 frames,
remote loop). Wander with a jitter frequency below 2 Hz is passed transparently.
The DCO-X accepts gapped clocks which are used in ATM or SDH/SONET applications.
The jitter attenuated clock is output on pin XCLK or optionally on pin CLK2.
In case of missing clock on pin SCLKX the DCO-X centers automatically, if selected by
bit CMR2.DCOXC = 1.
The transmit jitter attenuator can be disabled. In that case data is read from the transmit
elastic buffer with the clock sourced on pin TCLK (2.048 or 8.192 MHz). Synchronization
between SCLKX and TCLK has to be done externally.
In the loop-timed clock configuration (LIM2.ELT) the DCO-X circuitry generates a
transmit clock which is frequency synchronized on RCLK. In this configuration the
transmit elastic buffer has to be enabled.
Data Sheet
96
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
XL1/
XDOP/
XOID
XL2/
XDON
DR
D
DR
Framer
A
Transmit
Elastic
Store
XDI
Pulse Shaper
XCLK
TCLK
(E1: 8MHz)
(T1: 6MHz)
SCLKR
÷4
E1: 8MHz
T1: 6MHz
DCO-X
Transmit
Jitter
Attenuator
MCLK
Figure 24
Clocking
Unit
Internal Clock of
Receive System
Interface
SCLKX
TCLK
RCLK
ITS10305
Transmit Clock System (E1)
Note: DR = Dual-Rail interface
DCO-X Digital Controlled Oscillator transmit
4.4.4
Transmit Elastic Buffer (E1)
The received bit stream from pin XDI is optionally stored in the transmit elastic buffer.
The memory is organized as the receive elastic buffer. The functions are also equal to
the receive side. Programming of the transmit buffer size is done by SIC1.XBS1/0:
• XBS1/0 = 00: Bypass of the transmit elastic buffer
• XBS1/0 = 01: one frame buffer or 256 bits
Maximum of wander amplitude (peak-to-peak): 100 UI (1 UI = 488 ns)
average delay after performing a slip: 128 bits
• XBS1/0 = 10: two frame buffer or 512 bits
Maximum of wander amplitude: 190 UI
average delay after performing a slip: 1 frame or 256 bits
• XBS1/0 = 11: short buffer or 92 bits:
Maximum of wander amplitude: 18 us
average delay after performing a slip: 46 bits
The functions of the transmit buffer are:
Data Sheet
97
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
• Clock adaption between system clock (SCLKX) and internally generated transmit
route clock (XCLK).
• Compensation of input wander and jitter.
• Frame alignment between system frame and transmit route frame
• Reporting and controlling of slips
Writing of received data from XDI is controlled by SCLKX/R and SYPX/XMFS in
combination with the programmed offset values for the transmit time slot/clock slot
counters. Reading of stored data is controlled by the clock generated by DCO-X circuitry
or the externally generated TCLK and the transmit framer. With the de-jittered clock data
is read from the transmit elastic buffer and are forwarded to the transmitter. Reporting
and controlling of slips is done according to the receive direction. Positive/negative slips
are reported in interrupt status bits ISR4.XSP and ISR4.XSN. If the transmit buffer is
bypassed data is directly transferred to the transmitter.
The following table gives an overview of the transmit buffer operating modes.
Table 22
Transmit Buffer Operating Modes (E1)
SIC1.XBS(1:0)
Buffer Size
TS Offset
programming
Slip performance
00
bypass
enabled
no
11
short buffer
enabled
yes
01
1 frame
enabled
yes
10
2 frames
enabled
yes
4.4.5
Programmable Pulse Shaper (E1)
The analog transmitter includes a programmable pulse shaper to satisfy the
requirements of ITU-T I.431. The amplitude and shape of the transmit pulses are
completely programmable by registers XPM(2:0).
The transmitter requires an external step up transformer to drive the line.
4.4.6
Transmit Line Monitor (E1)
The transmit line monitor compares the transmit line current on XL1 and XL2 with an onchip transmit line current limiter. The monitor detects faults on the primary side of the
transformer indicated by a highly increased transmit line current (more than 120 mA for
at least 3 consecutive pulses sourced by VDDX1)) and protects the device from damage
by setting the transmit line driver XL1/2 into high-impedance state automatically (if
enabled by XPM2.DAXLT = 0). The current limiter checks the actual current value of
1)
shorts between XL1 or XL2 and VDDX are not detected
Data Sheet
98
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
XL1/2 and if the transmit line current drops below the detection limit the high-impedance
state is cleared.
Two conditions are detected by the monitor: transmit line de-jitteredity (more than 31
consecutive zeros) indicated by FRS1.XLO and transmit line high current indicated by
FRS1.XLS. In both cases a transmit line monitor status change interrupt is provided.
Line
Monitor
TRI
XL1
Pulse
Shaper
XL2
XDATA
ITS10936
Figure 25
4.4.7
Transmit Line Monitor Configuration (E1)
Transmit Signaling Controller (E1)
Similar to the receive signaling controller the same signaling methods and the same time
slot assignment is provided. The FALC56 performs the following signaling and data link
methods.
4.4.7.1
HDLC or LAPD access
The transmit signaling controller of the FALC56 performs the flag generation, CRC
generation, zero-bit stuffing and programmable idle code generation. Buffering of
transmit data is done in the 64 byte deep XFIFO. The signaling information is internally
multiplexed with the data applied to port XDI or XSIG.
In signaling controller transparent mode, fully transparent data transmission without
HDLC framing is performed. Optionally the FALC56 supports the continuous
transmission of the XFIFO contents.
The FALC56 offers the flexibility to insert data during certain time slots. Any
combinations of time slots can be programmed separately for the receive and transmit
direction if using HDLC channel 1. HDLC channel 2 and 3 support one programmable
time slot common for receive and transmit direction each.
Data Sheet
99
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.4.7.2
Support of Signaling System #7
The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is
described in ITU-Q.703. The following description assumes, that the reader is familiar
with the SS7 protocol definition.
SS7 support must be activated by setting the MODE register. Data stored in the transmit
FIFO (XFIFO) is sent automatically. The SS7 protocol is supported by the following
hardware features in transmit direction:
• transmission of flags at the beginning of each Signaling Unit
• bit stuffing (zero insertion)
• calculation of the CRC16 checksum:
The transmitter adds the checksum to each Signaling Unit.
Each Signaling Unit written to the transmit FIFO (XFIFO, 2×32 bytes) is sent once or
repeatedly including flags, CRC checksum and stuffed bits. After e.g. an MSU has been
transmitted completely, the FALC56 optionally starts sending of FISUs containing the
forward sequence number (FSN) and the backward sequence number (BSN) of the
previously transmitted Signaling Unit. Setting bit CCR5.AFX causes Fill In Signaling
Units (FISUs) to be sent continuously, if no HDLC or Signaling Unit (SU) is to be
transmitted from XFIFO. During update of XFIFO, automatic transmission is interrupted
and resumed after update is completed. The internally generated FISUs contain FSN
and BSN of the last transmitted Signaling Unit written to XFIFO.
Using CMDR.XREP = 1, the contents of XFIFO can be sent continuously. Clearing of
CMDR.XRES/SRES stops the automatic repetition of transmission. This function is also
available for HDLC frames, so no flag generation, CRC byte generation and bit stuffing
is necessary.
Example: After an MSU has been sent repetitively and XREP has been cleared, FISUs
are sent automatically.
4.4.7.3
Sa-Bit Access (E1)
The FALC56 supports the Sa-bit signaling of time slot 0 of every other frame as follows:
• the access through register XSW
• the access through registers XSA(8:4), capable of storing the information for a
complete multiframe
• the access through the 64 byte deep XFIFO of the signaling controller (HDLC channel
1 only)
This Sa-bit access gives the opportunity to transparent a bit stream as well as HDLC
frames where the signaling controller automatically processes the HDLC protocol. Any
combination of Sa-bits which shall be inserted in the outgoing data stream can be
selected by XC0.SA(8:4).
Data Sheet
100
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.4.7.4
Channel Associated Signaling CAS (E1, serial mode)
In external signaling mode (serial mode) the signaling data received on port XSIG is
sampled with the working clock of the transmit system interface (SCLKX) in combination
with the transmit synchronization pulse (SYPX). Data on XSIG is latched in the bit
positions 5 to 8 per time slot, bits 1 to 4 are ignored. Time slots 0 and 16 are sampled
completely (bit 1 to 8). The received CAS multiframe is inserted frame aligned into the
data stream on XDI and must be valid during the last frame of a multiframe if CRC4/
multiframe mode is selected. The CAS multiframe is aligned to the CRC4-multiframe;
other frames are ignored. Data sourced by the internal signaling controller (µP access
mode) overwrites the external signaling data.
If the FALC56 is configured for no signaling, the system interface data stream passes
the FALC56 undisturbedly.
Note: CAS data on XSIG is read in the last frame of a multiframe only and ignored in all
other frames.
125 µs
SYPX
SCLKX
T
TS31
TS0
TS1
TS16
TS31
XDI
4 56 7
FAS/NFAS
0 12 34 5 67
0 12 34 5 67
01 2 34 5 67
XSIG
ABCD
FAS/NFAS
A BCD
0 0 0 0XYXX
A BCD
T
FAS
NFAS
ABCD
0000XYXX
Figure 26
4.4.7.5
= Time slot offset (XC0, XC1)
= Frame alignment signal, is taken from XSIG, not from XDI
= TS0 not containing FAS
= Signaling bits for time slots 1...15 and 17...31 of CAS multiframe
= CAS multiframe alignment signal, has to be provided in TS16
F0132
2.048 MHz Transmit Signaling Highway (E1)
Channel Associated Signaling CAS (E1, µP access mode)
Transmit data stored in registers XS(16:1) is transmitted on a multiframe boundary in
time slot 16. The signaling controller inserts the bit stream either on the transmit line side
or, if external signaling is enabled, on the transmit system side using pin function XSIG.
Data sourced by the internal signaling controller overwrites the external signaling data.
If the FALC56 is configured for no signaling, the system interface data stream passes
the FALC56 undisturbedly.
Data Sheet
101
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.5
System Interface in E1 Mode
The FALC56 offers a flexible feature for system designers where for transmit and receive
direction different system clocks and system pulses are necessary. The interface to the
receive system highway is realized by two data buses, one for the data RDO and one for
the signaling data RSIG. The receive highway is clocked on pin SCLKR, while the
interface to the transmit system highway is independently clocked on pin SCLKX. The
frequency of these working clocks and the data rate of 2.048/4.096/8.192/16.384 Mbit/s
for the receive and transmit system interface is programmable by SIC1.SSC1/0, and
SIC1.SSD1, FMR1.SSD0. Selectable system clock and data rates and their valid
combinations are shown in the table below
Table 23
System Clocking and Data Rates (E1)
System Data Rate
Clock Rate
2.048 MHz
Clock Rate
4.096 MHz
Clock Rate
8.192 MHz
Clock Rate
16.384 MHz
2.048 Mbit/s
x
x
x
x
4.096 Mbit/s
--
x
x
x
8.192 Mbit/s
--
--
x
x
16.384 Mbit/s
--
--
--
x
x = valid, -- = invalid
Generally the data or marker on the system interface are clocked off or latched on the
rising or falling edge (SIC3.RESR/X) of the SCLKR/X clock. Some clocking rates allow
transmission of time slots in different channel phases. Each channel phase which shall
be active on ports RDO, XDI, RP(A:D) and XP(A:D) is programmable by SIC2.SICS(2:0),
the remaining channel phases are cleared or ignored.
The signals on pin SYPR together with the assigned time slot offset in register RC0 and
RC1 define the beginning of a frame on the receive system highway.The signal on pin
SYPX or XMFS together with the assigned time slot offset in register XC0 and XC1
define the beginning of a frame on the transmit system highway.
Adjusting the frame begin (time slot 0, bit 0) relative to SYPR/X or XMFS is possible in
the range of 0 to 125 µs. The minimum shift of varying the time slot 0 begin can be
programmed between 1 bit and 1/8 bit depending of the system clocking and data rate,
e.g. with a clocking/data rate of 2.048 MHz shifting is done bit by bit, while running the
FALC56 with 16.384 MHz and 2.048 Mbit/s data rate it is done by 1/8 bit.
A receive frame marker RFM can be activated during any bit position of the entire frame.
Programming is done with registers RC1/0. The pin function RFM is selected by
PC(4:1).RPC(2:0) = 001. The RFM selection disables the internal time slot assigner, no
offset programming is performed. The receive frame marker is active high for one
Data Sheet
102
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
2.048 MHz cycle and is clocked off with the rising or falling edge of the clock which is in/
output on port SCLKR (see SIC3.RESR/X).
Compared to the receive path the inverse functions are performed for the transmit
direction.
The interface to the transmit system highway is realized by two data buses, one for the
data XDI and one for the signaling data XSIG. The time slot assignment is equivalent to
the receive direction.
Latching of data is controlled by the system clock (SCLKX) and the synchronization
pulse (SYPX/XMFS) in combination with the programmed offset values for the transmit
time slot/clock slot counters XC1/0. The frequency of the working clock of 2.048/4.096/
8.192/16.384 MHz for the transmit system interface is programmable by SIC1.SSC1/0.
Refer also toTable 23.
The received bit stream on ports XDI and XSIG can be multiplexed internally on a time
slot basis, if enabled by SIC3.TTRF = 1. The data received on port XSIG can be sampled
if the transmit signaling marker XSIGM is active high. Data on port XDI is sampled if
XSIGM is low for the corresponding time slot. Programming the XSIGM marker is done
with registers TTR(4:1).
Data Sheet
103
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
SCLKR
DCO-R
RSIGM
Receive
Signaling
Buffer
RSIG
RMFB
Receive
Elastic
Buffer
RFM
RP(A...D)
DLR
FREEZE
RFSP
SYPR
Receive
Backplane
DCO-R
BYP
Receive
Data
Receive
Jitter
Attenuator
Receive
Clock
RDO
DCO-R
SCLKX
XLT
Transmit
Signaling
Buffer
XSIG
SYPX
XP(A...D)
XMFS
Transmit
Backplane
Transmit
Elastic
Buffer
TCLK
XSIGM
XMFB
DLX
XCLK
Transmit
Data
Transmit
Clock
Figure 27
Data Sheet
BYP
PLB
XDI
Transmit
Jitter
Attenuator
TCLK
RCLK
F0118
System Interface (E1)
104
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Multi Frame 1
Multi Frame 2
~ ~
Receive System Interface (E1)
~ ~
4.5.1
FRAME 1 FRAME 2 FRAME 3
RDO
FRAME 15 FRAME 16 FRAME 1 FRAME 2
FRAME 15
~~
~~ ~~
RMFB
SYPR
SYPR
Sample
Edge
Trigger
Edge 1)
SCLKR
8.192 MHz
T
Programmable via RC0/1
SCLKR
2.048 MHz
TS0
RDO/RSIG
Bit 255
2 Mbit/s Data Rate
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
RDO/RSIG
4 Mbit/s Data Rate
(SCLKR = 8.192 MHz)
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
Bit 255
RDO/RSIG
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
4 Mbit/s Data Rate
(SCLKR = 8.192 MHz)
DLR
marks any
Sa Bit
Sa-Bit Marker
XC0 . SA8E-SA4E
4 Mbit Interface
RFM
Receive Frame Marker
RC0/1
2 Mbit Interface
4 Mbit Interface
marks any
bit position
2 Mbit Interface
RSIGM
marks any
Time-Slot
Time-Slot Marker
RTR1...4
1)
only falling trigger edge shown, depending on Bit SIC3.RESR
Figure 28
Data Sheet
ITD10951
Receive System Interface Clocking (E1)
105
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.5.1.1
Receive Offset Programming
Depending on the selection of the synchronization signals (SYPR or RFM), different
calculation formulas are used to define the position of the synchronization pulses. These
formulas are given below, see Figure 29 to Figure 32 for explanation. The pulse length
of SYPR and RFM is always the basic E1 bit width (488 ns), independent of the selected
system highway clock and data frequency.
SYPR Offset Calculation
T:
Time between beginning of SYPR pulse and beginning of next frame
(time slot 0, bit 0), measured in number of SCLKR clock intervals
maximum delay: Tmax = (256 × SC/SD) - 1
SD:
Basic data rate; 2.048 Mbit/s
SC:
System clock rate; 2.048, 4.096, 8.192, or 16.384 MHz
X:
Programming value to be written to registers RC0 and RC1 (see page 239).
0 ≤ T ≤ 4:
X=4-T
5 ≤ T ≤ Tmax: X = 2052 - T
RFM Offset Calculation
MP:
Marker position of RFM, counting in SCLKR clock cycles
(0 = bit 1, time slot 0, channel phase 0)
SC = 2.048 MHz:
SC = 4.096 MHz:
SC = 8.192 MHz:
SC = 16.384 MHz:
0 ≤ MP ≤ 255
0 ≤ MP ≤ 511
0 ≤ MP ≤ 1023
0 ≤ MP ≤ 2047
SD:
Basic data rate; 2.048 Mbit/s
SC:
System clock rate; 2.048, 4.096, 8.192, or 16.384 MHz
X:
Programming value to be written to registers RC0 and RC1 (see page 239).
0
≤ MP ≤ 2045:
2046 ≤ MP ≤ 2047:
Data Sheet
X = MP + 2
X = MP - 2046
106
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
TS0
RDO
TS1
TS31
1234567 812345678
TS0
TS1
1234567812 34567812345678
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
SYPR
T=0
256 - T
T
SYPR
T
SYPR
F0221A
Figure 29
SYPR Offset Programming (2.048 Mbit/s, 2.048 MHz)
TS0 - CP0
RDO (CP0)
RDO (CP1)
TS0 - CP1
TS31-CP3
1234567 8
TS0 - CP0
TS0 - CP1
12 345678
12345678
RDO (CP3)
12345678
12345678
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
SYPR
T=0
SC/SD x 256 - T
T
SYPR
T
SYPR
(TS = time slot, CP = channel phase)
Figure 30
Data Sheet
F0221B
SYPR Offset Programming (8.192 Mbit/s, 8.192 MHz)
107
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
TS0
RDO
TS1
TS31
1234567 812345678
TS0
TS1
1234567812 34567812345678
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
RFM
BP = 0
RFM
BP = 12
RFM
BP = 251
F0221C
Figure 31
RFM Offset Programming (2.048 Mbit/s, 2.048 MHz)
TS0 - CP0
RDO (CP0)
RDO (CP1)
TS0 - CP1
TS31-CP3
1234567 8
TS0 - CP0
TS0 - CP1
12 345678
12345678
RDO (CP3)
12345678
12345678
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
RFM
BP = 0
RFM
BP = 12
RFM
BP = 1020
Figure 32
Data Sheet
byte-interleaved (TS = time slot, CP = channel phase)
F0221D
RFM Offset Programming (8.192 Mbit/s, 8.192 MHz)
108
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.5.2
Transmit System Interface (E1)
Multi Frame 1
XDI
FRAME0
FRAME1
FRAME2
Multi Frame 2
FRAME15
FRAME0
FRAME1
FRAME2
XMFB
XMFS
SYPX
Bit 0 Sample Edge 1)
Trigger Edge
1)
SYPX
T 2)
SCLKX
XSIGM
XDI/XSIG
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
TS0
DLX
Bit 4
marked
Sa-Bit Marker
XC0.SA8E-SA4E
1)
2)
Figure 33
Data Sheet
only falling edge mode shown
delay T is programmable by XC0/1;
F0003
Transmit System Interface Clocking: 2.048 MHz (E1)
109
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
Multi Frame 1
XDI
FRAME0
FRAME1
FRAME2
Multi Frame 2
FRAME15
FRAME0
FRAME1
FRAME2
XMFB
XMFS
SYPX
Bit 0 Sample Edge 1)
Trigger Edge 1)
SYPX
T 2)
SCLKX
XSIGM
Time-Slot Marker
TTR1...4
SIC2.SICS2-0=000
XDI/XSIG3)
1
SIC2.SICS2-0=000
2
3
4
5
XDI/XSIG3)
6
7
8
1
SIC2.SICS2-0=001
2
3
4
5
6
7
8
DLX
Sa-Bit Marker
XC0.SA8E-SA4E
SIC2.SICS2-0=000
Bit 4
marked
DLX
Sa-Bit Marker
XC0.SA8E-SA4E
SIC2.SICS2-0=000
1)
only falling edge mode shown
2) delay T is programmable by XC0/1;
3) data 4.096 Mbit/s, clock 8.192 MHz
Figure 34
Data Sheet
Bit 4
marked
F0004
Transmit System Interface Clocking: 8.192 MHz/4.096 Mbit/s (E1)
110
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.5.2.1
Transmit Offset Programming
The pulse length of SYPX is always the basic E1 bit width (488 ns), independent of the
selected system highway clock and data frequency.
SYPX Offset Calculation
T:
Time between beginning of SYPX pulse and beginning of next frame
(time slot 0, bit 0), measured in number of SCLKX clock intervals
maximum delay: Tmax = (256 × SC/SD) - 1
SD:
Basic data rate; 2.048 Mbit/s
SC:
System clock rate; 2.048, 4.096, 8.192, or 16.384 MHz
X:
Programming value to be written to registers XC0 and XC1 (see page 237).
0 ≤ T ≤ 4:
X=4-T
5 ≤ T ≤ Tmax: X = 256 × SC/SD - T + 4
Data Sheet
111
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
TS0
XDI
TS1
TS31
12 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TS0
TS1
1 2 3 4 5 67 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
SCLKX
SIC3.RESX = 1
(rising edge)
SCLKX
SIC3.RESX = 0
(falling edge)
SYPX
T=0
256 - T
T
SYPX
T
SYPX
F0223A
Figure 35
SYPX Offset Programming (2.048 Mbit/s, 2.048 MHz)
TS0 - CP0
XDI (CP0)
XDI (CP1)
TS0 - CP1
TS31-CP3
1 23 4 5 6 7 8
TS0 - CP0
TS0 - CP1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
XDI (CP3)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SCLKX
SIC3.RESX = 1
(rising edge)
SCLKX
SIC3.RESX = 0
(falling edge)
SYPX
T=0
SC/SD x 256 - T
T
SYPX
T
SYPX
Figure 36
Data Sheet
(TS = time slot, CP = channel phase)
F0223B
SYPX Offset Programming (8.192 Mbit/s, 8.192 MHz)
112
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.5.3
Time Slot Assigner (E1)
HDLC channel 1 offers the flexibility to connect data during certain time slots, as defined
by registers RTR(4:1) and TTR(4:1), to the RFIFO and XFIFO, respectively. Any
combinations of time slots can be programmed for the receive and transmit directions. If
CCR1.EITS = 1 the selected time slots (RTR(4:1)) are stored in the RFIFO of the
signaling controller and the XFIFO contents is inserted into the transmit path as
controlled by registers TTR(4:1).
For HDLC channels 2 and 3, one out of 31 time slots can be selected for each channel,
but in common for transmit and receive direction.
Within selected time slots single bit positions can be masked to be used/not used for
HDLC transmission for all HDLC channels. Additionally, the use of even, odd or both
frames can be selected for each HDLC channel individually.
Table 24
Time Slot Assigner HDLC Channel 1 (E1)
Receive
Time Slot
Register
Transmit
Time Slot
Register
Time Slots
Receive
Time Slot
Register
Transmit
Time Slot
Register
Time Slots
RTR 1.7
TTR 1.7
0
RTR 3.7
TTR 3.7
16
RTR 1.6
TTR 1.6
1
RTR 3.6
TTR 3.6
17
RTR 1.5
TTR 1.5
2
RTR 3.5
TTR 3.5
18
RTR 1.4
TTR 1.4
3
RTR 3.4
TTR 3.4
19
RTR 1.3
TTR 1.3
4
RTR 3.3
TTR 3.3
20
RTR 1.2
TTR 1.2
5
RTR 3.2
TTR 3.2
21
RTR 1.1
TTR 1.1
6
RTR 3.1
TTR 3.1
22
RTR 1.0
TTR 1.0
7
RTR 3.0
TTR 3.0
23
RTR 2.7
TTR 2.7
8
RTR 4.7
TTR 4.7
24
RTR 2.6
TTR 2.6
9
RTR 4.6
TTR 4.6
25
RTR 2.5
TTR 2.5
10
RTR 4.5
TTR 4.5
26
RTR 2.4
TTR 2.4
11
RTR 4.4
TTR 4.4
27
RTR 2.3
TTR 2.3
12
RTR 4.3
TTR 4.3
28
RTR 2.2
TTR 2.2
13
RTR 4.2
TTR 4.2
29
RTR 2.1
TTR 2.1
14
RTR 4.1
TTR 4.1
30
RTR 2.0
TTR 2.0
15
RTR 4.0
TTR 4.0
31
Data Sheet
113
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.6
Test Functions (E1)
4.6.1
Pseudo-Random Binary Sequence Generation and Monitor
The FALC56 has the ability to generate and monitor 215-1 and 220-1 pseudo-random
binary sequences (PRBS). The generated PRBS pattern is transmitted to the remote end
on pins XL1/2 or XDOP/N and can be inverted optionally. Generating and monitoring of
PRBS pattern is done according to ITU-T O.151.
The PRBS monitor senses the PRBS pattern in the incoming data stream.
Synchronization is done on the inverted and non-inverted PRBS pattern. The current
synchronization status is reported in status and interrupt status registers. Enabled by bit
LCR1.EPRM each PRBS bit error increments an error counter (CEC2). Synchronization
is reached within 400 ms with a probability of 99.9% at a bit error rate of up to 10-1.
The PRBS generator and monitor can be used to handle either a framed
(TPC0.FRA = 1) or an unframed (TPC0.FRA = 0) data stream.
4.6.2
Remote Loop
In the remote loop-back mode the clock and data recovered from the line inputs RL1/2
or RDIP/RDIN are routed back to the line outputs XL1/2 or XDOP/XDON through the
analog or digital transmitter. As in normal mode they are also processed by the
synchronizer and then sent to the system interface. The remote loop-back mode is
selected by setting the corresponding control bits LIM1.RL and LIM1.JATT. Received
data can be looped with or without the transmit jitter attenuator (FIFO).
RCLK
RL1
RL2
Clock +
Data
Recovery
Rec.
Framer
Elast.
Store
RDO
Trans.
Framer
Elast.
Store
XDI
FIFO
XL1
MUX
XL2
XCLK
Figure 37
Data Sheet
MUX
RCLK
DCO-R/X
ITS09750
Remote Loop (E1)
114
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.6.3
Payload Loop-Back
To perform an effective circuit test a payload loop is implemented. The payload loopback (FMR2.PLB) loops the data stream from the receiver section back to transmitter
section. The looped data passes the complete receiver including the wander and jitter
compensation in the receive elastic store and is output on pin RDO. Instead of the data
an AIS signal (FMR2.SAIS) can be sent to the system interface.
The framing bits, CRC4 and spare bits are not looped, if XSP.TT0 = 0. They are
generated by the FALC56 transmitter. If the PLB is enabled the transmitter and the data
on pins XL1/2 or XDOP/XDON are clocked with SCLKR instead of SCLKX. If
XSP.TT0 = 1 the received time slot 0 is sent back transparently to the line interface. Data
on the following pins is ignored: XDI, XSIG, SCLKX, SYPX and XMFS. All the received
data is processed normally.
RCLK
RL1
RL2
AIS-GEN
MUX
Clock +
Data
Recovery
Rec.
Framer
Elast.
Store
RDO
SCLKR
XL1
XL2
Elast.
Store
Trans.
Framer
XDI
SCLKX
ITS09748
Figure 38
Data Sheet
Payload Loop (E1)
115
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.6.4
Local Loop
The local loop-back mode selected by LIM0.LL = 1 disconnects the receive lines RL1/2
or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data
provided by the system interface is routed through the analog receiver back to the
system interface. However, the bit stream is transmitted undisturbedly on the line.
However, an AIS to the distant end can be enabled by setting FMR1.XAIS = 1 without
influencing the data looped back to the system interface.
Note that enabling the local loop usually invokes an out-of-frame error until the receiver
resynchronizes to the new framing. The serial codes for transmitter and receiver have to
be identical.
RCLK
RL2
Clock +
Data
Recovery
Rec.
Framer
Elast.
Store
RDO
XL1
MUX
Trans.
Framer
Elast.
Store
XDI
RL1
XL2
AIS-GEN
ITS09749
Figure 39
Data Sheet
Local Loop (E1)
116
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.6.5
Single Channel Loop-Back
Each of the 32 time slots can be selected for loop-back from the system PCM input (XDI)
to the system PCM output (RDO). This loop-back is programmed for one time slot at a
time selected by register LOOP. During loop-back, an idle channel code programmed in
register IDLE is transmitted to the remote end in the corresponding PCM route time slot.
For the time slot test, sending sequences of test patterns like a 1-kHz check signal shall
be avoided. Otherwise an increased occurrence of slips in the tested time slot disturbs
testing. These slips do not influence the other time slots and the function of the receive
memory. The usage of a quasi-static test pattern is recommended.
RCLK
RL1
RL2
XL1
XL2
Clock +
Data
Recovery
Trans.
Framer
MUX
Rec.
Framer
MUX
IDLE Code
Figure 40
Data Sheet
Elast.
Store
RDO
Elast.
Store
XDI
ITS09747
Single Channel Loop-Back (E1)
117
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description E1
4.6.6
Alarm Simulation (E1)
Alarm simulation does not affect the normal operation of the device, i.e. all time slots
remain available for transmission. However, possible real alarm conditions are not
reported to the processor or to the remote end when the device is in the alarm simulation
mode.
The alarm simulation is initiated by setting the bit FMR0.SIM. The following alarms are
simulated:
•
•
•
•
•
•
•
•
•
•
•
Loss-Of-Signal (LOS)
Alarm Indication Signal (AIS)
Loss of pulse frame
Remote alarm indication
Receive and transmit slip indication
Framing error counter
Code violation counter (HDB3 Code)
CRC4 error counter
E-Bit error counter
CEC2 counter
CEC3 counter
Some of the above indications are only simulated if the FALC56 is configured to a mode
where the alarm is applicable (e.g. no CRC4 error simulation when doubleframe format
is enabled).
Setting of the bit FMR0.SIM initiates alarm simulation, interrupt status bits are set. Error
counting and indication occurs while this bit is set. After it is reset all simulated error
conditions disappear, but the generated interrupt statuses are still pending until the
corresponding interrupt status register is read. Alarms like AIS and LOS are cleared
automatically. Interrupt status registers and error counters are automatically cleared on
read.
4.6.7
Single Bit Defect Insertion
Single bit defects can be inserted into the transmit data stream for the following
functions:
FAS defect, multiframe defect, CRC defect, CAS defect, PRBS defect and bipolar
violation.
Defect insertion is controlled by register IERR.
Data Sheet
118
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5
Functional Description T1/J1
5.1
Receive Path in T1/J1 Mode
RL1/RDIP/ROID
RL2/RDIN/RCLKI
Clock &
Data
Recovery
DPLL
Equalizer
Analog
LOS
Detector
Line
Decoder
Alarm
Detector
DCO-R
Receive Jitter
Attenuator
SYNC
RDATA
RCLK
Receive
System
Interface
FSC
F0117
MCLK
Figure 41
5.1.1
Receive Clock System (T1/J1)
Receive Line Interface (T1/J1)
For data input, three different data types are supported:
• Ternary coded signals received at multifunction ports RL1 and RL2 from a -36 dB
ternary interface. The ternary interface is selected if LIM1.DRS is reset.
• Digital dual-rail signals received on ports RDIP and RDIN. The dual-rail interface is
selected if LIM1.DRS and FMR0.RC1 is set.
• Unipolar data on port ROID received from a fiber-optical interface. The optical
interface is selected if LIM1.DRS is set and FMR0.RC1 is reset.
5.1.2
Receive Short and Long-Haul Interface (T1/J1)
The FALC56 has an integrated short-haul and long-haul line interface, including a
receive equalization network, noise filtering and programmable line build-outs (LBO).
Data Sheet
119
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.1.3
Receive Equalization Network (T1/J1)
The FALC56 automatically recovers the signals received on pins RL1/2. The maximum
reachable length with a 22 AWG twisted-pair cable is 2000 m (~6560 ft.). After reset the
FALC56 is in short-haul mode, received signals are recovered up to -10 dB of cable
attenuation. Switching into long-haul mode is done by setting of bit LIM0.EQON = 1.
The integrated receive equalization network recovers signals with up to -36 dB of cable
attenuation in long-haul mode. Noise filters eliminate the higher frequency part of the
received signals. The incoming data is peak-detected and sliced to produce the digital
data stream. The slicing level is software selectable in four steps (45%, 50%, 55%, 67%).
The received data is then forwarded to the clock and data recovery unit.
5.1.4
Receive Line Attenuation Indication (T1/J1)
Status register RES reports the current receive line attenuation in a range from 0 to
-36 dB in 25 steps of approximately 1.4 dB each. The least significant 5 bits of this
register indicate the cable attenuation in dB. These 5 bits are only valid in combination
with the most significant two bits (RES.EV1/0 = 01).
5.1.5
Receive Clock and Data Recovery (T1/J1)
The analog received signal on port RL1/2 is equalized and then peak-detected to
produce a digital signal. The digital received signal on port RDIP/N is directly forwarded
to the DPLL. The receive clock and data recovery extracts the route clock RCLK from
the data stream received at the RL1/2, RDIP/RDIN or ROID lines and converts the data
stream into a single-rail, unipolar bit stream. The clock and data recovery uses an
internally generated high frequency clock based on MCLK.
The recovered route clock or a de-jittered clock can be output on pin RCLK as shown in
Table 25.
See also Table 28 on page 126 for details of master/slave clocking.
Data Sheet
120
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Table 25
RCLK Output Selection (T1/J1)
Clock Source
RCLK Frequency
CMR1. CMR1. SIC2.
DCS
RS1/0 SSC2
Receive Data
(1.544 Mbit/s on RL1/RL2,
RDIP/RDIN or ROID)
1.544 MHz
X
00
X
Receive Data
in case of LOS
constant high
X
01
X
1.544 MHz
(generated by DCO-R,
synchronized on SYNC)
1
10
1
DCO-R
1.544 MHz
X
10
1
2.048 MHz
X
10
0
6.176 MHz
X
11
1
8.192 MHz
X
11
0
The intrinsic jitter generated in the absence of any input jitter is not more than 0.035 UI.
In digital bipolar line interface mode the clock and data recovery requires HDB3 coded
signals with 50% duty cycle.
5.1.6
Receive Line Coding (T1/J1)
The B8ZS line code or the AMI (ZCS, zero code suppression) coding is provided for the
data received from the ternary or the dual-rail interface. All code violations that do not
correspond to zero substitution rules are detected. The detected errors increment the
code violation counter (16 bits length). In case of the optical interface a selection
between the NRZ code and the CMI Code (1T2B) with B8ZS or AMI postprocessing is
provided. If CMI code is selected the receive route clock is recovered from the data
stream. The CMI decoder does not correct any errors. In case of NRZ coding data is
latched with the falling edge RCLKI.
When using the optical interface with NRZ coding, the decoder is bypassed and no code
violations are detected.
Additionally, the receive line interface contains the alarm detection for Alarm Indication
Signal AIS (Blue Alarm) and the loss-of-signal LOS (Red Alarm).
The signal at the ternary interface is received at both ends of a transformer.
Data Sheet
121
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
RL1
Line
t2
t1
R
R2
FALC
RL2
ITS10967
Figure 42
Receiver Configuration (T1/J1)
Table 26
Recommended Receiver Configuration Values (T1/J1)
Characteristic Impedance [Ω]
Parameter1)
R2 (± 1%) [Ω]
t2 : t1
1)
T1
J1
100
110
1:1
This includes all parasitic effects caused by circuit board design.
Data Sheet
122
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.1.7
Receive Line Monitoring Mode
For short-haul applications like shown in Figure 43, the receive equalizer can be
switched into receive line monitoring mode (LIM0.RLM = 1). One device is used as a
short-haul receiver while the other is used as a short-haul monitor. In this mode the
receiver sensitivity is increased to detect an incoming signal of -20 dB resistive
attenuation. The required resistor values are given in Table 27.
t2 : t1
RL1
E1/T1/J1
Receive
Line
R1
FALC®
(Receiver)
RL2
LIM0.RLM=0
R3
R3
t2 : t1
RL1
FALC®
(Monitor)
R2
RL2
resistive -20 dB network
LIM0.RLM=1
F0074
Figure 43
Receive Line Monitoring
Table 27
External Component Recommendations (Monitoring)
Parameter1)
R1 (± 1 %) [Ω]
R2 (± 1 %) [Ω]
R3 (± 1 %) [Ω]
t2 : t1
1)
Characteristic Impedance [Ω]
T1
J1
100
110
100
110
100
110
430
470
1:1
1:1
This includes all parasitic effects caused by circuit board design.
Using the receive line monitor mode and the hardware tristate function of transmit lines
XL1/2, the FALC56 now supports applications connecting two devices to one receive
Data Sheet
123
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
and transmission line. In these kind of applications both devices are working in parallel
for redundancy purpose (see Figure 44). While one of them is driving the line, the other
one must be switched into transmit line tristate mode. If both channels are configured
identically and supplied with the same system data and clocks, the transmit path can be
switched from one channel to the other without causing a synchronization loss at the
remote end.
XL1
E1/T1/J1
Transmit
Line
XDI
XL2
RL1
FALC®
(active)
E1/T1/J1
Receive Line
RDO
RL2
TRIST
1
XL1
XDI
XL2
RL1
FALC®
(stand by)
RDO
RL2
TRIST
F0075
Figure 44
5.1.8
Protection Switching Application
Loss-of-Signal Detection (T1/J1)
There are different definitions for detecting Loss-Of-Signal alarms (LOS) in the ITU-T
G.775 and AT&T TR 54016. The FALC56 covers all these standards. The LOS indication
is performed by generating an interrupt (if not masked) and activating a status bit.
Additionally a LOS status change interrupt is programmable by register GCR.SCI.
Data Sheet
124
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
• Detection:
An alarm is generated if the incoming data stream has no pulses (no transitions) for a
certain number (N) of consecutive pulse periods. “No pulse” in the digital receive
interface means a logical zero on pins RDIP/RDIN or ROID. A pulse with an amplitude
less than Q dB below nominal is the criteria for “no pulse” in the analog receive
interface (LIM1.DRS = 0). The receive signal level Q is programmable by three control
bits LIM1.RIL(2:0) (see Chapter 11.3 on page 447). The number N is set by an 8 bit
register (PCD). The contents of the PCD register is multiplied by 16, which results in
the number of pulse periods, i.e. the time which has to suspend until the alarm has to
be detected. The programmable range is 16 to 4096 pulse periods.
• Recovery:
In general the recovery procedure starts after detecting a logical "1" (digital receive
interface) or a pulse (analog receive interface) with an amplitude more than Q dB
(defined by LIM1.RIL(2:0)) of the nominal pulse. The value in the 8 bit register PCR
defines the number of pulses (1 to 255) to clear the LOS alarm. Additional recovery
conditions are programmed by register LIM2.
If a loss-of-signal condition is detected in long-haul mode, the data stream can optionally
be cleared automatically to avoid bit errors before LOS is indicated. The selection is
done by LIM1.CLOS = 1.
5.1.9
Receive Jitter Attenuator (T1/J1)
The receive jitter attenuator is placed in the receive path. The working clock is an
internally generated high frequency clock based on the clock provided on pin MCLK. The
jitter attenuator meets the requirements of PUB 62411, PUB 43802, TR-TSY 009,TRTSY 253, TR-TSY 499 and ITU-T I.431, G.703 and G. 824.
The internal PLL circuitry DCO-R generates a "jitter-free" output clock which is directly
depending on the phase difference of the incoming clock and the jitter attenuated
clock.The receive jitter attenuator can be synchronized either on the extracted receive
clock RCLK or on a 1.544-, 2.048-MHz or 8-kHz clock provided on pin SYNC (8 kHz in
master mode only). The received data is written into the receive elastic buffer with RCLK
and are read out with the de-jittered clock sourced by DCO-R. The jitter attenuated clock
can be output on pins RCLK, CLK1 or SCLKR. Optionally an 8-kHz clock is provided on
pin SEC/FSC.
The DCO-R circuitry attenuates the incoming jittered clock starting at 6-Hz jitter
frequency with 20 dB per decade fall-off. Wander with a jitter frequency below 6 Hz is
passed unattenuated. The intrinsic jitter in the absence of any input jitter is < 0.02 UI.
For some applications it might be useful starting of jitter attenuation at lower frequencies.
Therefore the corner frequency is switchable by the factor of ten down to 0.6 Hz
(LIM2.SCF).
The DCO-R circuitry is automatically centered to the nominal bit rate if the reference
clock on pin SYNC/RCLK is missed for 2, 3 or 4 of the 2.048-MHz or 1.544-MHz clock
Data Sheet
125
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
periods. This center function of DCO-R can be optionally disabled (CMR2.DCF = 1) in
order to accept a gapped reference clock.
In analog line interface mode the RCLK is always running. Only in digital line interface
mode with single-rail data (NRZ) a gapped clock on pin RCLK can occur.
The receive jitter attenuator works in two different modes:
• Slave mode
In slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the recovered route
clock. In case of LOS the DCO-R switches automatically to master mode. If bit
CMR1.DCS is set automatic switching from RCLK to SYNC is disabled.
• Master mode
In master mode (LIM0.MAS = 1) the jitter attenuator is in free running mode if no clock
is supplied on pin SYNC. If an external clock on the SYNC input is applied, the DCOR synchronizes to this input. The external frequency can be 1.544 MHz
(LIM1.DCOC = 0; IPC.SSYF = 0), 2.048 MHz (LIM1.DCOC = 1; IPC.SSYF = 0) or 8.0
kHz (IPC.SSYF = 1; LIM1.DCOC = don’t care).
The following table shows the clock modes with the corresponding synchronization
sources.
Table 28
System Clocking (T1/J1)
Mode
Internal
SYNC
LOS Active Input
System Clocks
Master
independent Fixed to
VDD
DCO-R centered, if CMR2.DCF = 0.
(CMR2.DCF should not be set)
Master
independent 1.544 MHz Synchronized on SYNC input (external
1.544 MHz, IPC.SSYF = 0, LIM1.DCOC = 0)
Master
independent 2.048 MHz Synchronized on SYNC input (external
2.048 MHz, IPC.SSYF = 0, LIM1.DCOC = 1)
Master
independent 8.0 kHz
Synchronized on SYNC input (external 8.0 kHz,
IPC.SSYF = 1, CMR2.DCF = 0)
Slave
no
Fixed to
VDD
Synchronized on line RCLK
Slave
no
1.544 or
Synchronized on line RCLK
2.048 MHz
Data Sheet
126
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Table 28
System Clocking (T1/J1) (cont’d)
Mode
Internal
SYNC
LOS Active Input
System Clocks
Slave
yes
CMR1.DCS = 0:
DCO-R is centered, if CMR2.DCF = 0.
(CMR2.DCF should not be set)
Fixed to
VDD
CMR1.DCS = 1:
Synchronized on line RCLK
Slave
yes
1.544 or
CMR1.DCS = 0:
2.048 MHz Synchronized on SYNC input (external 1.544 or
2.048 MHz)
CMR1.DCS = 1:
Synchronized on line clock RCLK
The jitter attenuator meets the jitter transfer requirements of the PUB 62411,
PUB 43802, TR-TSY 009,TR-TSY 253, TR-TSY 499 and ITU-T I.431 and G.703 (refer
to Figure 45).
ITD10314
10
dB
0
PUB 62411_H
PUB 62411_L
FALC R
Attenuation
-10
Slope - 20 dB/Decade
-20
-30
Slope - 40 dB/Decade
-40
-50
-60
-70
1
10
100
1000
10000
Hz 100000
Frequency
Figure 45
Data Sheet
Jitter Attenuation Performance (T1/J1)
127
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.1.10
Jitter Tolerance (T1/J1)
The FALC56 receiver’s tolerance to input jitter complies with ITU, AT&T and Telcordia
requirements for T1 applications.
Figure 46 shows the curves of different input jitter specifications stated below as well as
the FALC56 performance.
1000
PUB 62411
TR-NWT 000499 Cat II
CCITT G.823
ITU-T I.431
FALC®
UI
Jitter Amplitude
100
10
1
0.1
1
10
100
1000
Jitter Frequency
Figure 46
Data Sheet
10000
Hz
100000
F0025
Jitter Tolerance (T1/J1)
128
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.1.11
Output Jitter (T1/J1)
According to the input jitter defined by PUB62411 the FALC56 generates the output jitter,
which is specified in Table 29 below.
Table 29
Output Jitter (T1/J1)
Specification
PUB 62411
Measurement Filter Bandwidth
Lower Cutoff
Upper Cutoff
Output Jitter
(UI peak to peak)
10 Hz
8 kHz
< 0.015
8 kHz
40 kHz
< 0.015
10 Hz
40 kHz
< 0.015
Broadband
5.1.12
< 0.02
Framer/Synchronizer (T1/J1)
The following functions are performed:
• Synchronization on pulse frame and multiframe
• Error indication when synchronization is lost. In this case, AIS is sent to the system
side automatically and remote alarm to the remote end if enabled.
• Initiating and controlling of resynchronization after reaching the asynchronous state.
This is done automatically by the FALC56 or user controlled by the microprocessor
interface.
• Detection of remote alarm (yellow alarm) indication from the incoming data stream.
• Separation of service bits and data link bits. This information is stored in special status
registers.
• Detection of framed or unframed in-band loop-up/-down code
• Generation of various maskable interrupt statuses of the receiver functions.
• Generation of control signals to synchronize the CRC checker, and the receive elastic
buffer.
If programmed and applicable to the selected multiframe format, CRC checking of the
incoming data stream is done by generating check bits for a CRC multiframe according
to the CRC6 procedure (refer to ITU-T G.704). These bits are compared with those
check bits that are received during the next CRC multiframe. If there is at least one
mismatch, the CRC error counter (16 bit) is incremented.
5.1.13
Receive Elastic Buffer (T1/J1)
The received bit stream is stored in the receive elastic buffer. The memory is organized
as a two-frame elastic buffer with a maximum size of 2 × 193 bit. The size of the elastic
buffer is configured independently for the receive and transmit direction. Programming
of the receive buffer size is done by SIC1.RBS1/0:
Data Sheet
129
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
• RBS1/0 = 00: two frame buffer or 386 bits
Maximum of wander amplitude (peak-to-peak): (1 UI = 648 ns)
System interface clocking rate: modulo 2.048 MHz:
142 UI in channel translation mode 0
78 UI in channel translation mode 1
System interface clocking rate: modulo 1.544 MHz:
Maximum of wander: 140 UI
average delay after performing a slip: 1 frame or 193 bits
• RBS1/0 = 01: one frame buffer or 193 bits
System interface clocking rate: modulo 2.048 MHz:
Maximum of wander: 70 UI in channel translation mode 0
Maximum of wander: 50 UI in channel translation mode 1
System interface clocking rate: modulo 1.544 MHz:
Maximum of wander: 74 UI
average delay after performing a slip: 96 bits
• RBS1/0 = 10: short buffer or 96 bits
System interface clocking rate: modulo 2.048 MHz:
Maximum of wander: 28 UI in channel translation mode 0; channel translation mode
1 not supported
System interface clocking rate: modulo 1.544 MHz:
Maximum of wander: 38 UI
average delay after performing a slip: 48 bits
• RBS1/0 = 11: Bypass of the receive elastic buffer
The functions are:
• Clock adaption between system clock (SCLKR) and internally generated route clock
(RCLK).
• Compensation of input wander and jitter.
• Frame alignment between system frame and receive route frame
• Reporting and controlling of slips
Controlled by special signals generated by the receiver, the unipolar bit stream is
converted into bit-parallel, time slot serial data which is circularly written to the elastic
buffer using internally generated Receive Route Clock (RCLK).
Reading of stored data is controlled by the system clock sourced by SCLKR or by the
receive jitter attenuator and the synchronization pulse (SYPR) together with the
programmed offset values for the receive time slot/clock slot counters. After conversion
into a serial data stream, the data is sent out on port RDO. If the receive buffer is
bypassed programming of the time slot offset is disabled and data is clocked off with
RCLK instead of SCLKR.
Data Sheet
130
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
The 24 received time slots (T1/J1) can be translated into the 32 system time slots (E1)
in two different channel translation modes (FMR1.CTM). Unequipped time slots are set
to FFH. See Table 30.
Table 30
Channel Translation Modes (DS1/J1)
Channels
Time Slots
Channel
Translation
Mode 0
Channel
Translation
Mode 1
FS/DL
FS/DL
1
Channels
Time Slots
Channel
Translation
Mode 0
Channel
Translation
Mode 1
0
–
16
16
1
1
13
17
17
2
2
2
14
18
18
3
3
3
15
19
19
–
4
4
–
20
20
4
5
5
16
21
21
5
6
6
17
22
22
6
7
7
18
23
23
–
8
8
–
24
24
7
9
9
19
–
25
8
10
10
20
–
26
9
11
11
21
–
27
–
12
12
–
–
28
10
13
13
22
–
29
11
14
14
23
–
30
12
15
15
24
–
31
– : FFH
In one frame or short buffer mode the delay through the receive buffer is reduced to an
average delay of 96 or 48 bits. In bypass mode the time slot assigner is disabled. In this
case SYPR programmed as input is ignored. Slips are performed in all buffer modes
except the bypass mode. After a slip is detected the read pointer is adjusted to one half
of the current buffer size.
The following table gives an overview of the receive buffer operating mode.
Data Sheet
131
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Table 31
Receive Buffer Operation Modes (T1/J1)
Buffer Size
(SIC1.RBS1/0)
TS Offset program.
(RC1/0) + SYPR = input
Slip perform.
bypass1)
disabled
no
short buffer
not recommended,
recommended:
SYPR = output
yes
1 frame
not recommended,
recommended:
SYPR = output
yes
2 frames
enabled
yes
1)
In bypass mode the clock provided on pin SCLKR is ignored. Clocking is done with RCLK.
Figure 47 gives an idea of operation of the receive elastic buffer:
A slip condition is detected when the write pointer (W) and the read pointer (R) of the
memory are nearly coincident, i.e. the read pointer is within the slip limits (S +, S –). If a
slip condition is detected, a negative slip (one frame or one half of the current buffer size
is skipped) or a positive slip (one frame or one half of the current buffer size is read out
twice) is performed at the system interface, depending on the difference between RCLK
and the current working clock of the receive backplane interface, i.e. on the position of
pointer R and W within the memory. A positive/negative slip is indicated by the interrupt
status bits ISR3.RSP and ISR3.RSN.
Data Sheet
132
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Frame 2 Time Slots
R’
R
Slip
S-
S+
W
Frame 1 Time Slots
Moment of Slip Detection
W : Write Pointer (Route Clock controlled)
R : Read Pointer (System Clock controlled)
S+, S- : Limits for Slip Detection (mode dependent)
ITD10952
Figure 47
Data Sheet
The Receive Elastic Buffer as Circularly Organized Memory
133
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.1.14
Receive Signaling Controller (T1/J1)
The signaling controller can be programmed to operate in various signaling modes. The
FALC56 performs the following signaling and data link methods.
5.1.14.1 HDLC or LAPD access
The FALC56 offers three independent HDLC channels. All of them provide the following
features:
• 64 byte receive FIFO for each channel
• 64 byte transmit FIFO for each channel
• transmission in one of 24 time slots
(time slot number programmable for each channel individually)
• transmission in even frames only, odd frames only or both
(programmable for each channel individually)
• bit positions to be used in selected time slots are maskable
(any bit position can be enabled for each channel individually)
• HDLC or transparent mode
• flag detection
• CRC checking
• bit-stuffing
• flexible address recognition (1 byte, 2 bytes)
• C/R bit processing (according to LAPD protocol)
In addition to this, HDLC channel 1 provides:
• SS7 support
• BOM (bit oriented message) support
• flexibility to insert and extract data during certain time slots, any combination of time
slots can be programmed independently for the receive and transmit direction
In case of common channel signaling the signaling procedure HDLC/SDLC or LAPD
according to Q.921 is supported. The signaling controller of the FALC56 performs the
flag detection, CRC checking, address comparison and zero bit removing. The received
data flow and the address recognition features can be performed in very flexible way, to
satisfy almost any practical requirements. Depending on the selected address mode, the
FALC56 performs a 1 or 2-byte address recognition. If a 2-byte address field is selected,
the high address byte is compared with the fixed value FEH or FCH (group address) as
well as with two individually programmable values in RAH1 and RAH2 registers.
According to the ISDN LAPD protocol, bit 1 of the high byte address is interpreted as
command/response bit (C/R) and is excluded from the address comparison. Buffering of
receive data is done in a 64 byte deep RFIFO.
In signaling controller transparent mode, fully transparent data reception without HDLC
Data Sheet
134
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
framing is performed, i.e. without flag recognition, CRC checking or bit stuffing. This
allows user specific protocol variations.
5.1.14.2 Support of Signaling System #7
The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is
described in ITU-Q.703. The following description assumes, that the reader is familiar
with the SS7 protocol definition.
SS7 support must be activated by setting the MODE register. The SS7 protocol is
supported by the following hardware features in receive mode:
•
•
•
•
•
all Signaling Units (SU) are stored in the receive FIFO (RFIFO)
detecting of flags from the incoming data stream
bit stuffing (zero deletion)
checking of seven or more consecutive ones in the receive data stream
checking if the received Signaling Unit is a multiple of eight bits and at least six octets
including the opening flag
• calculation of the CRC16 checksum:
In receive direction the calculated checksum is compared to the received one; errors
are reported in register RSIS.
• checking if the signal information field of a received signaling unit consists of more
than 272 octets, in this case the current signaling unit is discarded.
In order to reduce the microprocessor load, fill In signaling units (FISUs) are processed
automatically. By examining the length indicator of a received signal unit the FALC56
decides whether a FISU has been received. Consecutively received FISUs are
compared and optionally not stored in the receive FIFO (RFIFO, 2×32 bytes), if the
contents is equal to the previous one. The same applies to link status signaling units, if
bit CCR5.CSF is set. The different types of signaling units as message signaling unit
(MSU), link status signaling unit (LSSU) and fill in signaling units (FISU) are indicated in
the RSIS register, which is automatically added to the RFIFO with each received
signaling unit. The complete signaling unit except start and end flags is stored in the
receive FIFO. The functions of bits CCR1.RCRC and CCR1.RADD are still valid in SS7
mode. Errored signaling units are handled automatically according to ITU-T Q.703 as
shown in Figure 20. SU counter (su) and errored SU counter (Cs) are reset by setting
CMDR2.RSUC. The error threshold T can be selected to be 64 (default) or 32 by setting/
clearing bit CCR5.SUET. If the defined error limit is exceeded, an interrupt (ISR1.SUEX)
is generated, if not masked by IMR1.SUEX = 1.
Note: If SUEX is caused by an aborted/invalid frame, the interrupt will be issued
regularly until a valid frame is received (e.g. a FISU).
Data Sheet
135
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Idle
Reset Counter values
Cs := 0
su := 0
[CMDR2.RSUC = 1]
in service
N
SU in error?
Y
Cs := Cs + 1
su := su + 1
Cs = T ?
su := su + 1
N
N
Y
su = 256 ?
Y
Link failure
[ISR1.SUEX = 1]
su := 0
Idle
Cs = 0 ?
Y
N
Notes:
su: signaling units counter
Cs: errored signaling units
counter
T: error threshold (64 or 32),
selectable by CCR5.SUET
Figure 48
Data Sheet
Cs := Cs -1
in service
F0071
Automatic Handling of Errored Signaling Units
136
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.1.14.3 CAS Bit-Robbing (T1/J1, serial mode)
The signaling information is carried in the LSB of every sixth frame for each time slot.
The signaling controller samples the bit stream either on the receive line side or if
external signaling is enabled on the receive system side on port RSIG. Receive signaling
data is stored in the registers RS(12:1).
Optionally the complete CAS multiframe is transmitted on pin RSIG (FMR5.EIBR = 1).
The signaling data is clocked out with the working clock of the receive highway (SCLKR)
together with the receive synchronization pulse (SYPR). Data on RSIG is transmitted in
the last 4 bits per time slot and are time slot aligned to the data on RDO. In ESF format
the A,B,C,D bits are placed in the bit positions 5 to 8 per time slot. In F12/72 format the
A and B bits are repeated in the C and D bit positions. The first 4 bits per time slot can
be optionally fixed high or low. The FS/DL time slot is transmitted on RDO and RSIG.
During idle time slots no signaling information is transmitted. Data on RSIG are only valid
if the freeze signaling status is inactive. With FMR2.SAIS all-ones data is transmitted on
RDO and RSIG.
Updating of the received signaling information is controlled by the freeze signaling
status. The freeze signaling status is automatically activated if a loss-of-signal, or a lossof-frame-alignment or a receive slip occurs. The current freeze status is output on port
FREEZE (RP(A:D)) and indicated by register SIS.SFS. If SIS.SFS is active updating of
the registers RS(12:1) is disabled. Optionally automatic freeze signaling is disabled by
setting bit SIC3.DAF.
After CAS resynchronization an interrupt is generated. Because at this time the signaling
is still frozen, CAS data is not valid yet. Readout of CAS data has to be delayed until the
next CAS multiframe is received.
5.1.14.4 CAS Bit-Robbing (T1/J1, µP access mode)
The signaling information is carried in the LSB of every sixth frame for each time slot.
Receive data is stored in registers RS(12:1) aligned to the CAS multiframe boundary.
To relieve the µP load from always reading the complete RS(12:1) buffer every 3 ms the
FALC56 notifies the µP by interrupt ISR0.RSC only when signaling changes from one
multiframe to the next. Additionally the FALC56 generates a receive signaling data
change pointer (RSP1/2) which directly points to the updated RS(12:1) register.
Because the CAS controller is working on the PCM highway side of the receive buffer,
slips disturb the CAS data.
5.1.14.5 Bit Oriented Messages in ESF-DL Channel (T1/J1)
The FALC56 HDLC channel 1 supports the DL-channel protocol for ESF format
according to ANSI T1.403 specification or according to AT&T TR54016. The HDLC and
bit oriented message (BOM) receiver are switched on/off independently. If the FALC56
is used for HDLC formats only, the BOM receiver has to be switched off. If HDLC and
Data Sheet
137
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
BOM receiver have been switched on (MODE.HRAC/BRAC), an automatic switching
between HDLC and BOM mode is enabled. If eight or more consecutive ones are
detected, the BOM mode is entered. Upon detection of a flag in the data stream, the
FALC56 switches back to HDLC mode. In BOM mode, the following byte format is
assumed (the left most bit is received first): 111111110xxxxxx0
Three different BOM reception modes can be programmed (CCR1.BRM+ CCR2.RBFE).
If CCR2.RFBE is set, the BOM receiver accepts only BOM frames after detecting 7 out
of 10 equal BOM pattern. Buffering of receive data is done in a 64 byte deep RFIFO.
5.1.14.6 4 kbit/s Data Link Access in F72 Format (T1/J1)
The DL-channel protocol is supported as follows:
• access is done on a multiframe basis through registers RDL(3:1),
• the DL-bit information from frame 26 to 72 is stored in the receive FIFO of the signaling
controller.
Data Sheet
138
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.2
Framer Operating Modes (T1/J1)
5.2.1
General
Activated with bit FMR1.PMOD = 1.
PCM line bit rate
Single frame length
Framing frequency
Organization
:
:
:
:
1.544 Mbit/s
193 bit, No. 1…193
8 kHz
24 time slots, No. 1…24
with 8 bits each, No. 1…8 and one preceding F-bit
Selection of one of the four permissible framing formats is performed by bits FMR4.FM1/
0. These formats are:
F4
F12
ESF
F72
:
:
:
:
4-frame multiframe
12-frame multiframe (D4)
Extended Superframe (F24)
72-frame multiframe (SLC96)
The operating mode of the FALC56 is selected by programming the carrier data rate and
characteristics, line code, multiframe structure, and signaling scheme.
The FALC56 implements all of the standard and/or common framing structures PCM24
(T1/J1, 1.544 Mbit/s) carriers. The internal HDLC controller supports all signaling
procedures including signaling frame synchronization/synthesis in all framing formats.
After reset, the FALC56 must be programmed with FMR1.PMOD = 1 to enable the T1/
J1 (PCM24) mode. Switching between the framing formats is done by bit FMR4.FM1⁄0
for the receiver and for the transmitter.
5.2.2
General Aspects of Synchronization
Synchronization status is reported by bit FRS0.LFA (Loss Of Frame Alignment). Framing
errors (pulse frame and multiframe) are counted by the Framing Error Counter FEC.
Asynchronous state is reached if
2 out of 4 (bit FMR4.SSC1/0 = 00), or
2 out of 5 (bit FMR4.SSC1/0 = 01), or
2 out of 6 (bit FMR4.SSC1/0 = 10), or
4 consecutive multiframe pattern in ESF format are incorrect (bit FMR4.SSC1/0 = 11).
If auto mode is enabled, counting of framing errors is interrupted.
The resynchronization procedure is controlled by either one of the following procedures:
• Automatically (FMR4.AUTO = 1). Additionally, it can be triggered by the user by
setting/resetting one of the bits FMR0.FRS (force resynchronization) or FMR0.EXLS
(external loss of frame).
Data Sheet
139
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
• User controlled, exclusively, by the control bits described above in the non-auto mode
(FMR4.AUTO = 0).
5.2.3
Addition for F12 and F72 Format
FT and FS bit conditions, i.e. pulse frame alignment and multiframe alignment can be
handled separately if programmed by bit FMR2.SSP. Thus, a multiframe
resynchronization can be automatically initiated after detecting 2 errors out of 4/5/6
consecutive multiframing bits without influencing the state of the terminal framing.
In the synchronous state, the setting of FMR0.FRS or FMR0.EXLS resets the
synchronizer and initiates a new frame search. The synchronous state is reached if there
is only one definite framing candidate. In the case of repeated apparent simulated
candidates, the synchronizer remains in the asynchronous state.
In asynchronous state, the function of FMR0.EXLS is the same as above. Setting bit
FMR0.FRS induces the synchronizer to lock onto the next available framing candidate if
there is one. Otherwise a new frame search is started. This is useful in case the framing
pattern that defines the pulseframe position is imitated periodically by a pattern in one of
the speech/data channels.
The control bit FMR0.EXLS should be used first because it starts the synchronizer to
search for a definite framing candidate.
To observe actions of the synchronizer, the Frame Search Restart Flag FRS0.FSRF is
implemented. It toggles at the start of a new frame search if no candidate has been found
at previous attempt.
When resynchronization is initiated, the following values apply for the time required to
achieve the synchronous state in case there is one definite framing candidate within the
data stream:
Table 32
Resynchronization Timing (T1/J1)
Frame Mode
Average
Maximum
Units
F4
F12
ESF
F72
1.0
3.5
3.4
13.0
1.5
4.5
6.125
17.75
ms
Data Sheet
140
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Auto-Mode
Definite Candidate
Non-Auto-Mode
Definite Candidate
DON
Multiple Candidates
EXLS, FRS
EXLS, FRS
FRS
FRS
DON
DON
Synchronous
DOFF
1)
DOFF
EXLS
EXLS
FRS
FRS
: Depends on the Disturbance
D : One Disturbance
Asynchronous
Multiple Candidates
Asynchronous
Synchronous
EXLS, FRS
1)
Data Sheet
DON
DOFF
DOFF
Figure 49
Asynchronous
Synchronous
Synchronous
FRS
EXLS, FRS
Asynchronous
EXLS
ITD03574
Influences on Synchronization Status (T1/J1)
141
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Figure 49 gives an overview of influences on synchronization status for the case of
different external actions. Activation of auto mode and non-auto mode is performed by
bit FMR4.AUTO. Generally, for initiating resynchronization it is recommended to use bit:
FMR0.EXLS first. In cases where the synchronizer remains in the asynchronous state,
bit FMR0.FRS is used to enforce it to lock onto the next framing candidate, although it
might be a simulated one.
5.2.4
4-Frame Multiframe (F4 Format, T1/J1)
The allocation of the FT-bits (bit 1 of frames 1 and 3) for frame alignment signal is shown
in Table 33.
The FS-bit can be used for signaling. Remote alarm (yellow alarm) is indicated by setting
bit 2 to 0 in each time slot.
Table 33
4-Frame Multiframe Structure (T1/J1)
Frame Number
FT
1
2
3
4
1
–
0
–
5.2.4.1
FS
service bit
service bit
Synchronization Procedure
For multiframe synchronization, the terminal framing bits (FT-bits) are observed. The
synchronous state is reached if at least one terminal framing candidate is definitely
found, or the synchronizer is forced to lock onto the next available candidate
(FMR0.FRS).
Data Sheet
142
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.2.5
12-Frame Multiframe (D4 or SF Format, T1/J1)
Normally, this kind of multiframe structure only makes sense when using the CAS
robbed-bit signaling. The multiframe alignment signal is located at the FS-bit position of
every other frame (refer to Table 34).
Table 34
12-Frame Multiframe Structure (T1/J1)
Frame Number
FT
FS
1
2
3
4
5
6
7
8
9
10
11
12
1
–
0
–
1
–
0
–
1
–
0
–
–
0
–
0
–
1
–
1
–
1
–
0
Signaling Channel
Designation
A
B
There are two possibilities of remote alarm (yellow alarm) indication:
• Bit 2 = 0 in each time slot of a frame, selected with bit FMR0.SRAF = 0
• The last bit of the multiframe alignment signal (bit 1 of frame 12) changes from "0" to
"1", selected with bit FMR0.SRAF = 1.
5.2.5.1
Synchronization Procedure
In the synchronous state terminal framing (FT-bits) and multiframing (FS-bits) are
observed, independently. Further reaction on framing errors depends on the selected
synchronization/resynchronization procedure (by bit FMR2.SSP):
• FMR2.SSP = 0: terminal frame and multiframe synchronization are combined.
Two errors within 4/5/6 framing bits (by bits FMR4.SSC1/0) of one of the above leads
to the asynchronous state for terminal framing and multiframing. Additionally to the bit
FRS0.LFA, loss of multiframe alignment is reported by bit FRS0.LMFA.
The resynchronization procedure starts with synchronizing upon the terminal framing.
If the pulse framing has been regained, the search for multiframe alignment is
initiated. Multiframe synchronization has been regained after two consecutive correct
multiframe patterns have been received.
• FMR2.SSP = 1: terminal frame and multiframe synchronization are separated
Two errors within 4/5/6 terminal framing bits lead to the same reaction as described
Data Sheet
143
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
above for the “combined” mode.
Two errors within 4/5/6 multiframing bits lead to the asynchronous state only for the
multiframing. Loss of multiframe alignment is reported by bit FRS0.LMFA. The state
of terminal framing is not influenced.
Now, the resynchronization procedure includes only the search for multiframe
alignment. Multiframe synchronization has been regained after two consecutive
correct multiframe patterns have been received.
5.2.6
Extended Superframe (F24 or ESF Format, T1/J1)
The use of the first bit of each frame for the multiframe alignment word, the data link bits,
and the CRC bits is shown in Table 35 on page 144.
Table 35
Extended Superframe Structure (F24, ESF; T1/J1)
Multiframe
Frame Number Multiframe
Bit Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Data Sheet
0
193
386
579
772
965
1158
1351
1544
1737
1930
2123
2316
2509
2702
2895
3088
3231
3474
3667
3860
4053
4246
4439
F-Bits
Assignments
FAS
DL
CRC
–
–
–
0
–
–
–
0
–
–
–
1
–
–
–
0
–
–
–
1
–
–
–
1
m
–
m
–
m
–
m
–
m
–
m
–
m
–
m
–
m
–
m
–
m
–
m
–
–
e1
–
–
–
e2
–
–
–
e3
–
–
–
e4
–
–
–
e5
–
–
–
e6
–
–
144
Signaling
Channel
Designation
A
B
C
D
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.2.6.1
Synchronization Procedures
For multiframe synchronization the FAS-bits are observed. Synchronous state is
reached if at least one framing candidate is definitely found, or the synchronizer is forced
to lock onto the next available candidate (FMR0.FRS).
In the synchronous state the framing bits (FAS-bits) are observed. The following
conditions selected by FMR4.SSC1/0 lead to the asynchronous state:
•
•
•
•
two errors within 4/5/6 framing bits
two or more erroneous framing bits within one ESF multiframe
more than 320 CRC6 errors per second interval (FMR5.SSC2)
4 incorrect (1 out of 6) consecutive multiframes independent of CRC6 errors.
There are four multiframe synchronization modes selectable using FMR2.MCSP and
FMR2.SSP.
• FMR2.MCSP/SSP = 00: In the synchronous state, the setting of FMR0.FRS or
FMR0.EXLS resets the synchronizer and initiates a new frame search. The
synchronous state is reached again, if there is only one definite framing candidate. In
the case of repeated apparent simulated candidates, the synchronizer remains in the
asynchronous state.
In asynchronous state, setting bit FMR0.FRS induces the synchronizer to lock onto
the next available framing candidate if there is one. At the same time the internal
framing pattern memory is cleared and other possible framing candidates are lost.
• FMR2.MCSP/SSP = 01: Synchronization is achieved when 3 consecutive multiframe
pattern are correctly found independent of the occurrence of CRC6 errors. If only one
or two consecutive multiframe pattern were detected the FALC56 stays in the
asynchronous state, searching for a possible additionally available framing pattern.
This procedure is repeated until the framer has found three consecutive multiframe
pattern in a row.
• FMR2.MCSP/SSP = 10: This mode has been added in order to be able to choose
multiple framing pattern candidates step by step. I.e. if in synchronous state the CRC
error counter indicates that the synchronization might have been based on an alias
framing pattern, setting of FMR0.FRS leads to synchronization on the next candidate
available. However, only the previously assumed candidate is discarded in the internal
framing pattern memory. The latter procedure can be repeated until the framer has
locked on the right pattern (no extensive CRC errors).
The synchronizer is reset completely and initiates a new frame search, if there is no
multiframing found. In this case bit FRS0.FSRF toggles.
• FMR2.MCSP/SSP = 11: Synchronization including automatic CRC6 checking
Synchronization is achieved when framing pattern are correctly found and the CRC6
checksum is received without an error. If the CRC6 check failed on the assumed
Data Sheet
145
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
framing pattern the FALC56 stays in the asynchronous state, searching for a possible
available framing pattern. This procedure is repeated until the framer has locked on
the right pattern. This automatic synchronization mode has been added in order to
reduce the microprocessor load.
5.2.6.2
Remote Alarm (yellow alarm) Generation/Detection
Remote alarm (yellow alarm) is indicated by the periodical pattern "1111 1111 0000 0000
…" in the DL-bits (T1 mode, RC0.SJR = 0). Remote alarm is declared even in the
presence of a bit error rate of up to 10-3. The alarm is reset when the yellow alarm pattern
no longer is detected.
Depending on bit RC0.SJR = 1 the FALC56 generates and detects the remote alarm
according to JT G. 704. In the DL-bit position 16 continuous "1" are transmitted if
FMR0.SRAF = 0 and FMR4.XRA = 1.
5.2.6.3
CRC6 Generation and Checking (T1/J1)
Generation and checking of CRC6 bits transmitted/received in the E(6:1) bit positions is
done according to ITU-T G.706. The CRC6 checking algorithm is enabled by bit
FMR1.CRC. If not enabled, all check bits in the transmit direction are set. In the
synchronous state received CRC6 errors are accumulated in a 16 bit error counter and
are additionally indicated by an interrupt status.
• CRC6 inversion
If enabled by bit RC0.CRCI, all CRC bits of one outgoing extended multiframe are
automatically inverted in case a CRC error is flagged for the previous received
multiframe. Setting the bit RC0.XCRCI inverts the CRC bits before transmitted to the
distant end. This function is logically ored with RC0.CRCI.
• CRC6 generation/checking according to JT G.706
Setting of RC0.SJR the FALC56 generates and checks the CRC6 bits according to
JT G.706. The CRC6 checksum is calculated including the FS/DL-bits. In synchronous
state CRC6 errors increment an error counter.
5.2.7
72-Frame Multiframe (SLC96 Format, T1/J1)
The 72-multiframe is an alternate use of the FS-bit pattern and is used for carrying data
link information. This is done by stealing some of redundant multiframing bits after the
transmission of the 12-bit framing header (refer to Figure 36 on page 148). The position
of A and B signaling channels (robbed bit signaling) is defined by zero-to-one and oneto-zero transitions of the FS-bits and is continued when the FS-bits are replaced by the
data link bits.
Data Sheet
146
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Remote alarm (yellow alarm) is indicated by setting bit 2 to zero in each time slot. An
additional use of the D-bits for alarm indication is user defined and must be done
externally.
5.2.7.1
Synchronization Procedure
In the synchronous state terminal framing (FT-bits) and multiframing (FS-bits of the
framing header) are observed independently. Further reaction on framing errors
depends on the selected synchronization/resynchronization procedure (by bit
FMR2.SSP):
• FMR2.SSP = 0: terminal frame and multiframe synchronization are combined
Two errors within 4/5/6 framing bits (by bits FMR4.SSC1/0) of one of the above lead
to the asynchronous state for terminal framing and multiframing. Additionally to The
resynchronization procedure starts with synchronizing upon the terminal framing. If
the pulse framing has been regained, the search for multiframe alignment is initiated.
Multiframe synchronization has been regained after two consecutive correct
multiframe patterns have been received.
• FMR2.SSP = 1: terminal frame and multiframe synchronization are separated
Two errors within 4/5/6 terminal framing bits lead to the same reaction as described
above for the “combined” mode.
Two errors within 4/5/6 multiframing bits lead to the asynchronous state only for the
multiframing. Loss of multiframe alignment is reported by bit FRS0.LMFA. The state
of terminal framing is not influenced.
Now, the resynchronization procedure includes only the search for multiframe
alignment. Multiframe synchronization has been regained after two consecutive
correct multiframe patterns have been received.
Data Sheet
147
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Table 36
72-Frame Multiframe Structure (T1/J1)
Frame Number
FT
FS
1
2
3
4
5
6
7
8
9
10
11
12
1
–
0
–
1
–
0
–
1
–
0
–
–
0
–
0
–
1
–
1
–
1
–
0
13
14
15
16
17
18
19
20
21
22
23
24
1
–
0
–
1
–
0
–
1
–
0
–
–
0
–
0
–
1
–
1
–
1
–
D
25
26
27
28
·
66
67
68
69
70
71
72
1
–
·
·
1
–
0
–
1
–
0
–
–
D
·
·
–
D
–
D
–
D
–
0
Data Sheet
148
Signaling Channel
Designation
A
B
A
B
A
B
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.2.8
Summary of Frame Conditions (T1/J1)
Table 37
Summary Frame Recover/Out of Frame Conditions (T1/J1)
Format
Frame Recover Condition
F4
only one FT pattern found, optional 2 out of 4/5/6 incorrect FT-bits
forcing on next available FT framing
candidate
F12 (D4)
FMR2.SSP = 0:
Combined FT + FS framing search:
First searching for FT pattern with
optional forcing on next available
framing candidates and then for 2
consecutive correct FS pattern1).
FMR2.SSP = 1:
Separated FT + FS pattern search:
Loss of FT framing starts first
search for FT and then for 2
consecutive correct FS pattern1).
Loss of FS framing starts only the
FS pattern1) search.
FMR2.SSP = 0: 2 out of 4/5/6
incorrect FT- or FS-bits
FMR2.SSP = 1:
2 out of 4/5/6 incorrect FT-bits
searched in FT and FS framing
bits,
2 out of 4/5/6 incorrect FS-bits
searched only the FS framing.
FMR2.MCSP/SSP = 00:
only one FAS pattern found,
optional forcing on next available
FAS framing candidate with
discarding of all remaining framing
candidates.
FMR2.MCSP/SSP = 01:
3 consecutive correct multiframing
found independent of CRC6 errors.
FMR2.MCSP/SSP = 10:
choosing multiple framing pattern
step by step, optional forcing on
next available FAS framing pattern
with discarding only of the previous
assumed framing candidate.
FMR2.MCSP/SSP = 11:
FAS framing correctly found and
CRC6 check error free.
2 out of 4/5 incorrect FAS-bits
or
2 out of 6 incorrect FAS-bits per
multiframe
or
4 consecutive incorrect
multiframing pattern
or
more than 320 CRC6 errors per
second interval
and
F72 (SLC96)
F24 (ESF)
1)
Out of Frame Condition
In F12 (D4) format bit 1 in frame 12 is excluded from the synchronization process.
Data Sheet
149
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.3
Additional Receive Framer Functions (T1/J1)
5.3.1
Error Performance Monitoring and Alarm Handling
• Alarm Indication Signal: Detection and recovery is flagged by bit FRS0.AIS and
ISR2.AIS. Transmission is enabled by bit FMR1.XAIS.
• Loss-Of-Signal: Detection and recovery is flagged by bit FRS0.LOS and ISR2.LOS.
• Remote Alarm Indication: Detection and release is flagged by bit FRS0.RRA and
ISR2.RA/RAR. Transmission is enabled by bit FMR4.XRA.
• Excessive Zeros: Detection is flagged by bit FRS1.EXZD.
• Pulse-Density Violation: Detection is flagged by bit FRS1.PDEN and ISR0.PDEN.
• Transmit Line Shorted: Detection and release is flagged by bit FRS1.XLS and
ISR1.XLSC.
• Transmit Ones-Density: Detection and release is flagged by bit FRS1.XLO and
ISR1.XLSC.
Table 38
Summary of Alarm Detection and Release (T1/J1)
Alarm
Detection Condition
Clear Condition
Red Alarm or
Loss-Of-Signal
(LOS)
no transitions (logical zeros) in a
programmable time interval of 16
to 4096 consecutive pulse
periods. Programmable receive
input signal threshold
programmable number of ones
(1 to 256) in a programmable
time interval of 16 to 4096
consecutive pulse periods. A one
is a signal with a level above the
programmed threshold.
or
the pulse-density is fulfilled and
no more than 15 contiguous
zeros during the recovery
interval are detected.
Blue Alarm or
Alarm Indication
Signal (AIS)
active for at least one multiframe.
FMR4.AIS3 = 0:
less than 3 zeros in 12 frames or FMR4.AIS3 = 0:
24 frames (ESF),
more than 2 zeros in 12 or 24
frames (ESF),
FMR4.AIS3 = 1:
less than 4 zeros in 12 frames or
less than 6 zeros in 24 frames
(ESF)
Data Sheet
150
FMR4.AIS3 = 1:
more than 3 zeros in 12 frames
or more than 5 zeros in 24
frames (ESF)
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Table 38
Summary of Alarm Detection and Release (T1/J1) (cont’d)
Alarm
Detection Condition
Clear Condition
Yellow Alarm or
Remote Alarm
(RRA)1)
RC1.RRAM = 0:
bit 2 = 0 in 255 consecutive time
slots or
FS-bit = 1 of frame12 in F12 (D4)
format or
8×1,8×0 in the DL channel (ESF)
RC1.RRAM = 1:
bit 2 = 0 in every time slot per
frame or
FS-bit = 1 of frame12 in F12 (D4)
format or
8×1,8×0 in the DL channel (ESF)
RC1.RRAM = 0:
set conditions no longer
detected.
Excessive Zeros
(EXZD)
more than 7 (B8ZS code) or
more than 15 (AMI code)
contiguous zeros
Latched Status: cleared on read
Pulse-Density
Violation
(PDEN)
less than N ones in each and
Latched Status: cleared on read
every time window of 8×(N+1)
time slots with N taking all values
of 1 to 23
or
more than 15 consecutive zeros
Transmit Line
Short
(XLS)
more than 3 pulse periods with
highly increased transmit line
current on XL1/2
transmit line current limiter
inactive
Transmit OnesDensity
(XLO)
32 consecutive zeros in the
transmit data stream on XL1/2
Cleared with each transmitted
pulse
1)
RC1.RRAM = 1:
bit 2 = 0 not detected in 3
consecutive frames or
FS-bit not detected in 3
consecutive multiframes or
8×1,8×0 not detected for 3 times
in a row (ESF).
RRA detection operates in the presence of 10-3 bit error rate.
5.3.2
Auto Modes
• Automatic remote alarm (Yellow Alarm) access
If the receiver has lost its synchronization (FRS0.LFA) a remote alarm (yellow alarm)
is sent to the distant end automatically, if enabled by bit FMR2.AXRA. In synchronous
state the remote alarm bit is removed.
• Automatic AIS to system interface
In asynchronous state the synchronizer enforces an AIS to the receive system
interface automatically. However, received data is switched through transparently if bit
FMR2.DAIS is set.
Data Sheet
151
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
• Automatic clock source switching
In slave mode (LIM0.MAS = 0) the DCO-R synchronizes on the recovered route clock.
In case of loss-of-signal (LOS) the DCO-R switches to master mode automatically. If
bit CMR1.DCS is set, automatic switching from RCLK to SYNC is disabled.
• Automatic freeze signaling:
Updating of the received signaling information is controlled by the freeze signaling
status. The freeze signaling status is activated automatically, if a loss-of-signal or a
loss of multiframe alignment or a receive slip occurs. The internal signaling buffer
RS(12:1) is frozen. Optionally automatic freeze signaling is disabled by setting bit
SIC3.DAF = 1.
5.3.3
Error Counter
The FALC56 offers six error counters where each of them has a length of 16 bit. They
record code violations, framing bit errors, CRC6 bit errors, errored blocks and the
number of received multiframes in asynchronous state or the changes of frame
alignment (COFA). Counting of the multiframes in asynchronous state and of the COFA
parameter is done in a 6/2-bit counter. Each of the error counters is buffered. Buffer
update is done in two modes:
• One-second accumulation
• On demand using handshake with writing to the DEC register.
In the one-second mode an internal/external one-second timer updates these buffers
and resets the counter to accumulate the error events in the next one-second period.
The error counter cannot overflow. Error events occurring during error counter reset are
not be lost.
5.3.4
Errored Second
The FALC56 supports the error performance monitoring by detecting the following
alarms or error events in the received data:
framing errors, CRC errors, code violations, loss of frame alignment, loss-of-signal,
alarm indication signal, receive and transmit slips.
With a programmable interrupt mask register ESM all these alarms or error events can
generate an Errored Second Interrupt (ISR3.ES) if enabled.
5.3.5
One-Second Timer
Additionally a one-second timer interrupt can be generated internally to indicate that the
enabled alarm status bits or the error counters have to be checked. The one-second
timer signal is output on port SEC/FSC (GPC1.CSFP1/0). Optionally synchronization to
an external second timer is possible which has to be provided on pin SEC/FSC.
Selecting the external second timer is done with GCR.SES. Refer also to register GPC1
for input/output selection.
Data Sheet
152
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.3.6
Clear Channel Capability
For support of common T1 applications, clear channels can be specified through the 3byte register bank CCB(1:3). In this mode the contents of selected transmit time slots are
not overwritten by internally or externally sourced bit-robbing and zero code suppression
(B7 stuffing) information.
5.3.7
In-Band Loop Generation and Detection
The FALC56 generates and detects a framed or unframed in-band loop-up (activate,
00001) and loop-down (deactivate, 001) pattern according to ANSI T1.403 with bit error
rates as high as 10-2. Framed or unframed in-band loop code is selected by LCR1.FLLB.
Replacing the in-band loop codes with transmit data is done by FMR5.XLD/XLU.
The FALC56 also offers the ability generating and detecting of a flexible in-band loop-up
and -down pattern (LCR1.LLBP = 1). The loop-up and loop-down pattern is individually
programmable from 2 to 8 bits in length (LCR1.LAC1/0 and LCR1.LDC1/0).
Programming of loop codes is done in registers LCR2 and LCR3.
Status and interrupt status bits inform the user whether loop-up or loop-down code was
detected.
5.3.8
Transparent Mode
The transparent modes are useful for loop-backs or for routing data unchanged through
the FALC56.
In receive direction, transparency for ternary or dual-/single-rail unipolar data is always
achieved if the receiver is in the synchronous state. All bits in F-bit position of the
incoming multiframe are forwarded to RDO and inserted in the FS/DL time slot or in the
F-bit position. In asynchronous state the received data is switched through transparently
if bit FMR2.DAIS is set. Setting of bit LOOP.RTM disconnects control of the elastic buffer
from the receiver. The elastic buffer is now in a “free running” mode without any
possibility to update the time slot assignment to a new frame position in case of
resynchronization of the receiver. Together with FMR2.DAIS this function is used to
realize undisturbed transparent reception.
Setting bit FMR4.TM switches the FALC56 in transmit transparent mode:
In transmit direction bit 8 of the FS/DL time slot from the system highway (XDI) is inserted
in the F-bit position of the outgoing frame. For complete transparency the internal
signaling controller, idle code generation, AIS alarm generation, single channel and
payload loop-back has to be disabled and cleared channels have to be defined by
registers CCB1…3.
5.3.9
Pulse-Density Detection
The FALC56 examines the receive data stream on the pulse-density requirement which
is defined by ANSI T1. 403. More than 14 consecutive zeros or less than N ones in each
Data Sheet
153
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
and every time window of 8×(N+1) data bits where N = 23 are detected. Violations of
these rules are indicated by setting the status bit FRS1.PDEN and the interrupt status bit
ISR0.PDEN. Generation of the interrupt status is programmed either with the detection
or with any change of state of the pulse-density alarm (GCR.SCI).
5.4
Transmit Path in T1/J1 Mode
5.4.1
Transmitter (T1/J1)
The serial bit stream is then processed by the transmitter which has the following
functions:
•
•
•
•
•
•
Frame/multiframe synthesis of one of the four selectable framing formats
Insertion of service and data link information
AIS generation (blue alarm)
Remote alarm (yellow alarm) generation
CRC generation and insertion of CRC bits
CRC bits inversion in case of a previously received CRC error or in case of activating
per control bit
• Generation of loop-up/-down code
• Idle code generation per DS0
The frame/multiframe boundaries of the transmitter can be synchronized externally by
using the SYPX/XMFS pin. Any change of the transmit time slot assignment
subsequently produces a change of the framing bit positions on the line side. This
feature is required if signaling and data link bits are routed through the switching network
and are inserted in transmit direction by the system interface.
In loop-timed configuration (LIM2.ELT) disconnecting the control of the transmit system
highway from the transmitter is done by setting FMR5.XTM. The transmitter is now in a
free running mode without any possibility to update the multiframe position in case of
changing the transmit time slot assignment. The FS/DL-bits are generated independent
of the transmit system interface. For proper operation the transmit elastic buffer size
should be programmed to 2 frames.
The contents of selectable time slots is overwritten by the pattern defined by register
IDLE. The selection of “idle channels” is done by programming the three-byte registers
ICB(3:1).
If AMI coding with zero code suppression (B7-stuffing) is selected, “clear channels”
without B7-stuffing can be defined by programming registers CCB(3:1).
5.4.2
Transmit Line Interface (T1/J1)
The analog transmitter transforms the unipolar bit stream to ternary (alternate bipolar)
return to zero signals of the appropriate programmable shape. The unipolar data is
provided on pin XDI and the digital transmitter.
Data Sheet
154
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Similar to the receive line interface three different data types are supported:
R1
XL1
Line
t1
t2
FALC R
R1
XL2
ITS10968
Figure 50
Transmitter Configuration (T1/J1)
Table 39
Recommended Transmitter Configuration Values (T1/J1)
Parameter
T1
J1
Characteristic Impedance [Ω]
100
110
R1 (± 1%) [Ω]
21)
t2 : t1
1)
1 : 2.4
This value refers to an ideal transformer without any parasitics. Any transformer resistance or other parasitic
resistances have to be taken into account when calculating the final value of the output serial resistors.
• Ternary Signal
Single-rail data is converted into a ternary signal which is output on pins XL1 and XL2.
Selection between B8ZS or simple AMI coding with zero code suppression (B7
stuffing) is provided. B7 stuffing can be disabled on a per time slot basis (Clear
Channel capability). Selected by FMR0.XC1/0 and LIM1.DRS = 0.
• Dual-rail data PCM(+), PCM(-) at multifunction ports XDOP and XDON with 50% or
100% duty cycle and with programmable polarity. Line coding is done in the same way
as in ternary interface mode. Selected by FMR0.XC1 = 1 and LIM1.DRS = 1.
• Unipolar data on port XOID is transmitted in NRZ (non return to zero) with 100% duty
cycle or in CMI code with or without (SIC3.CMI) preprocessed by B8ZS coding to a
fiber-optical interface. Clocking off data is done with the rising edge of the transmit
clock XCLK (1544 kHz) and with a programmable polarity. Selection is done by
FMR0.XC1 = 0 and LIM1.DRS = 1.
5.4.3
Transmit Jitter Attenuator (T1/J1)
The transmit jitter attenuator DCO-X circuitry generates a "jitter-free" transmit clock and
meets the following requirements: PUB 62411, PUB 43802, TR-TSY 009,TR-TSY 253,
TR-TSY 499 and ITU-T I.431 and G.703. The DCO-X circuitry works internally with the
Data Sheet
155
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
same high frequency clock as the receive jitter attenuator. It synchronizes either to the
working clock of the transmit backplane interface or the clock provided on pin TCLK or
the receive clock RCLK (remote loop/loop-timed). The DCO-X attenuates the incoming
jitter starting at 6 Hz with 20 dB per decade fall-off. With the jitter attenuated clock, which
is directly depending on the phase difference of the incoming clock and the jitter
attenuated clock, data is read from the transmit elastic buffer (2 frames) or from the JATT
buffer (2 frames, remote loop). Wander with a jitter frequency below 6 Hz is passed
transparently.
The DCO-X accepts gapped clocks which are used in ATM or SDH/SONET applications.
The jitter attenuated clock is output on pin XCLK or optionally on pin CLK2.
In case of missing clock on pin SCLKX the DCO-X centers automatically, if selected by
bit CMR2.DCOXC = 1.
The transmit jitter attenuator can be disabled. In that case data is read from the transmit
elastic buffer with the clock sourced on pin TCLK (1.544 or 6.176 MHz). Synchronization
between SCLKX and TCLK has to be done externally.
In the loop-timed clock configuration (LIM2.ELT) the DCO-X circuitry generates a
transmit clock which is frequency synchronized on RCLK. In this configuration the
transmit elastic buffer has to be enabled.
RCLK
RL1/2
RDIP/N
ROID
Equalizer
DPLL
Line
Decoder
Receive
Data
Line
Encoder
Transmit
Data
DRS
JATT
Buffer
Line
Driver
Pulse
Shaper
~
~
XL1/2
DRS
XDOP/N
XOID
RCLK
RCLK
Transmit
Jitter
Attenuator
Clock
Unit
MCLK
ITS10299
Figure 51
Data Sheet
Clocking in Remote Loop Configuration (T1/J1)
156
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
XL1/
XDOP/
XOID
XL2/
XDON
DR
D
DR
Framer
A
Transmit
Elastic
Store
XDI
Pulse Shaper
XCLK
TCLK
(E1: 8MHz)
(T1: 6MHz)
SCLKR
÷4
E1: 8MHz
T1: 6MHz
DCO-X
Transmit
Jitter
Attenuator
MCLK
Figure 52
Clocking
Unit
Internal Clock of
Receive System
Interface
SCLKX
TCLK
RCLK
ITS10305
Transmit Clock System (T1/J1)
Note: DR = Dual-Rail interface
DCO-X Digital Controlled Oscillator transmit
5.4.4
Transmit Elastic Buffer (T1/J1)
The transmit elastic store with a size of max. 2 × 193 bit (two frames) serves as a
temporary store for the PCM data to adapt the system clock (SCLKX) to the internally
generated clock for the transmit data, and to retranslate time slot structure used in the
system to that of the line side. Its optimal start position is initiated when programming the
transmit time slot offset values. A difference in the effective data rates of system side and
transmit side lead to an overflow or underflow of the transmit memory. Thus, errors in
data transmission to the remote end occur. This error condition (transmit slip) is reported
to the microprocessor by interrupt status registers.
The received bit stream from pin XDI is optionally stored in the transmit elastic buffer.
The memory is organized as the receive elastic buffer. Programming of the transmit
buffer size is done by SIC1.XBS1/0:
• XBS1/0 = 00: bypass of the transmit elastic buffer
• XBS1/0 = 01: one frame buffer or 193 bits
Maximum of wander amplitude (peak-to-peak): (1 UI = 648 ns)
System interface clocking rate: modulo 2.048 MHz:
Data Sheet
157
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Maximum of wander: 70 UI in channel translation mode 0
Maximum of wander: 45 UI in channel translation mode 1
System interface clocking rate: modulo 1.544 MHz:
Maximum of wander: 74 UI
average delay after performing a slip: 96 bits
• XBS1/0 = 10: two frame buffer or 386 bits
System interface clocking rate: modulo 2.048 MHz:
142 UI in channel translation mode 0
78 UI in channel translation mode 1
System interface clocking rate: modulo 1.544 MHz:
Maximum of wander: 140 UI
average delay after performing a slip: 193 bits
• XBS1/0 = 11: short buffer or 96 bits:
System interface clocking rate: modulo 2.048 MHz:
Maximum of wander: 28 UI in channel translation mode 0; channel translation mode
1 not supported
System interface clocking rate: modulo 1.544 MHz:
Maximum of wander: 38 UI
average delay after performing a slip: 48 bits
The functions of the transmit buffer are:
• Clock adaption between system clock (SCLKX/R) and internally generated transmit
route clock (XCLK) or externally sourced TCLK.
• Compensation of input wander and jitter.
• Frame alignment between system frame and transmit route frame
• Reporting and controlling of slips
Writing of received data from XDI is controlled by SCLKX/R and SYPX/XMFS in
combination with the programmed offset values for the transmit time slot/clock slot
counters. Reading of stored data is controlled by the clock generated by DCO-X circuitry
or the externally generated TCLK and the transmit framer. With the de-jittered clock data
is read from the transmit elastic buffer and are forwarded to the transmitter. Reporting
and controlling of slips is automatically done according to the receive direction. Positive/
negative slips are reported in interrupt status bits ISR4.XSP and ISR4.XSN.
A reinitialization of the transmit memory is done by reprogramming the transmit time slot
counter XC1 and with the next SYPX pulse. After that, this memory has its optimal start
position.
The frequency of the working clock for the transmit system interface is programmable by
SIC1.SSC1/0 and SIC2.SSC2 in a range of 1.544 to 12.352 MHz/2.048 to 16.384 MHz.
Generally the data or marker on the system interface are clocked off or latched on the
rising or falling edge (SIC3.RESX) of the SCLKX clock. Some clocking rates allow
transmission of time slots/marker in different channel phases. Each channel phase
Data Sheet
158
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
which shall be latched on ports XDI and XP(A:D) is programmable by bits
SIC2.SICS(2:0), the remaining channel phases are cleared or ignored respectively.
The following table gives an overview of the transmit buffer operating modes.
Table 40
Transmit Buffer Operating Modes (T1/J1)
Buffer Size
TS Offset programming
Slip performance
bypass
enabled
no
short buffer
disabled
yes
1 frame
enabled
yes
2 frames
enabled
yes
5.4.5
Programmable Pulse Shaper and Line Build-Out (T1/J1)
In long-haul applications the transmit pulse masks are optionally generated according to
FCC68 and ANSI T1. 403. To reduce the crosstalk on the received signals the
FALC56 offers the ability to place a transmit attenuator in the data path. Transmit
attenuation is selectable from 0, -7.5, -15 or -22.5 dB (register LIM2.LBO2/1).
ANSI T1. 403 defines only 0 to -15 dB.
The FALC56 includes a programmable pulse shaper to satisfy the requirements of ANSI
T1. 102, also various DS1, DSX-1 specifications are met. The amplitude of the pulse
shaper is individually programmable by the microprocessor to allow a maximum of
different pulse templates. The line length is selected by programming the registers
XPM(2:0) as shown for typical values in the table below. The values are optimized for
transformer ratio: 1:2.4; cable: PULP 22AWG (100 Ω); serial resistors: 2 Ω.
Table 41
Range in
m
Pulse Shaper Programming (T1/J1)
Range in
ft.
XPM0
XPM1
XPM2
XP04- XP14XP00 XP10
hexadecimal
XP24XP20
XP34XP30
decimal
0 to 40
0 to 133
D7
22
1
23
22
8
2
40 to 81
133 to 266 FA
26
1
26
23
9
2
81 to 122
266 to 399 3D
37
1
29
25
13
2
122 to 162 399 to 533 5F
3F
1
31
26
15
2
162 to 200 533 to 655 3F
CB
1
31
25
18
3
The transmitter requires an external step up transformer to drive the line.
Data Sheet
159
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.4.6
Transmit Line Monitor (T1/J1)
The transmit line monitor compares the transmit line current on XL1 and XL2 with an onchip transmit line current limiter. The monitor detects faults on the primary side of the
transformer indicated by a highly increased transmit line current (more than 120 mA for
at least 3 consecutive pulses sourced by VDDX1)) and protects the device from damage
by setting the transmit line driver XL1/2 into high-impedance state automatically (if
enabled by XPM2.DAXLT = 0). The current limiter checks the actual current value of
XL1/2 and if the transmit line current drops below the detection limit the high-impedance
state is cleared.
Two conditions are detected by the monitor: transmit line de-jitteredity (more than 31
consecutive zeros) indicated by FRS1.XLO and transmit line high current indicated by
FRS1.XLS. In both cases a transmit line monitor status change interrupt is provided.
Line
Monitor
TRI
XL1
Pulse
Shaper
XL2
XDATA
ITS10936
Figure 53
5.4.7
Transmit Line Monitor Configuration (T1/J1)
Transmit Signaling Controller (T1/J1)
Similar to the receive signaling controller the same signaling methods and the same time
slot assignment are provided. The FALC56 performs the following signaling and data link
methods.
5.4.7.1
HDLC or LAPD access
The transmit signaling controller of the FALC56 performs the flag generation, CRC
generation, zero bit stuffing and programmable idle code generation. Buffering of
transmit data is done in the 64 byte deep XFIFO. The signaling information is internally
multiplexed with the data applied to port XDI or XSIG.
In signaling controller transparent mode, fully transparent data transmission without
1)
shorts between XL1 or XL2 and VDDX are not detected
Data Sheet
160
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
HDLC framing is performed. Optionally the FALC56 supports the continuous
transmission of the XFIFO contents.
Operating in HDLC or BOM mode “flags” or “idle” are transmitted as interframe timefill.
The FALC56 offers the flexibility to insert data during certain time slots. Any
combinations of time slots can be programmed separately for the receive and transmit
direction if using HDLC channel 1. HDLC channel 2 and 3 support one programmable
time slot common for receive and transmit direction each.
5.4.7.2
Support of Signaling System #7
The HDLC controller of channel 1 supports the signaling system #7 (SS7) which is
described in ITU-Q.703. The following description assumes, that the reader is familiar
with the SS7 protocol definition.
SS7 support must be activated by setting the MODE register. Data stored in the transmit
FIFO (XFIFO) is sent automatically. The SS7 protocol is supported by the following
hardware features in transmit direction:
• transmission of flags at the beginning of each Signaling Unit
• bit stuffing (zero insertion)
• calculation of the CRC16 checksum:
The transmitter adds the checksum to each Signaling Unit.
Each signaling unit written to the transmit FIFO (XFIFO, 2×32 bytes) is sent once or
repeatedly including flags, CRC checksum and stuffed bits. After e.g. an MSU has
been transmitted completely, the FALC56 optionally starts sending of FISUs
containing the forward sequence number (FSN) and the backward sequence number
(BSN) of the previously transmitted signaling unit. Setting bit CCR5.AFX causes Fill
In Signaling Units (FISUs) to be sent continuously, if no HDLC or Signaling Unit (SU)
is to be transmitted from XFIFO. During update of XFIFO, automatic transmission is
interrupted and resumed after update is completed. The internally generated FISUs
contain FSN and BSN of the last transmitted signaling unit written to XFIFO.
Using CMDR.XREP = 1, the contents of XFIFO can be sent continuously. Clearing of
CMDR.XRES/SRES stops the automatic repetition of transmission. This function is
also available for HDLC frames, so no flag generation, CRC byte generation and bit
stuffing is necessary.
Example: After an MSU has been sent repetitively and XREP has been cleared,
FISUs are sent automatically.
5.4.7.3
CAS Bit-Robbing (T1/J1, serial mode)
The signaling controller inserts the bit stream either on the transmit line side or if external
signaling is enabled on the transmit system side. Signaling data is sourced on port XSIG,
which is selected by register PC(4:1) and FMR5.EIBR = 1.
Data Sheet
161
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
In external signaling mode the signaling data is sampled with the working clock of the
transmit system interface (SCLKX) together with the transmit synchronous pulse
(SYPX). Data on XSIG is latched in the bit positions 5 to 8 per time slot, bits 1 to 4 are
ignored. The FS/DL-bit is sampled on port XSIG and inserted in the outgoing data
stream. The received CAS multiframe is inserted frame aligned into the data stream on
XDI. Data sourced by the internal signaling controller overwrites the external signaling
data which must be valid during the last frame of a multiframe.
Internal multiplexing of data and signaling data can be disabled on a per time slot basis
(clear channel capability). This is also valid when using the internal and external
signaling mode.
5.4.7.4
CAS Bit-Robbing (T1/J1, µP access mode)
The signaling controller inserts the bit stream either on the transmit line side or if external
signaling is enabled on the transmit system side. Signaling data is sourced internally
from registers XS(12:1).
Internal multiplexing of data and signaling data can be disabled on a per time slot basis
(clear channel capability). This is also valid when using the internal and external
signaling mode.
5.4.7.5
Data Link Access in ESF/F24 and F72 Format (T1/J1)
The DL-channel protocol is supported as follows:
• access is done on a multiframe basis through registers XDL(3:1) or
• HDLC access or transparent transmission (non HDLC mode) from XFIFO (HDLC
channel 1 only)
The signaling information stored in the XFIFO is inserted in the DL-bits of frame 26 to 72
in F72 format or in every other frame in ESF format. Transmission can be done on a
multiframe boundary (CCR1.XMFA = 1). Operating in HDLC or BOM mode “flags” or
“idle” are transmitted as interframe timefill.
5.4.7.6
Periodical Performance Report in ESF Format (T1/J1)
According to ANSI T1.403 the FALC56 can automatically generate the Periodical
Performance Report (PPR) and transmit it every second in the data link channel of the
extended superframe format (ESF/F24 only). Automatic sending of this report can be
enabled/disabled by the use of bit CCR5.EPR. A single report can be initiated manually
at any time (by setting CMDR2.XPPR = 1).
Performance information is sampled every second and the report contains data of the
last four seconds as shown in the following tables.
Data Sheet
162
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
.
Table 42
Structure of Periodical Performance Report (T1/J1)1)
Octet No.
8
7
6
5
4
3
2
1
1
FLAG
=
01111110
2
SAPI
=
001110
CR2)
EA=0
3
TEI
=
0000000
4
CONTROL = 00000011 = unacklowledged frame
EA=1
5
G3
LV
G4
U1
U2
G5
SL
G6
6
FE
SE
LB
G1
R
G2
Nm
N1
7
G3
LV
G4
U1
U2
G5
SL
G6
8
FE
SE
LB
G1
R
G2
Nm
N1
9
G3
LV
G4
U1
U2
G5
SL
G6
10
FE
SE
LB
G1
R
G2
Nm
N1
11
G3
LV
G4
U1
U2
G5
SL
G6
12
FE
SE
LB
G1
R
G2
Nm
N1
13
FCS
14
FCS
15
FLAG
=
time
t0
t0-1 s
t0-2 s
t0-3 s
01111110
1)
The rightmost bit (bit 1) is transmitted first for all fields except for the two bytes of the FCS that are transmitted
leftmost bit (bit 8) first.
2)
reflects state of bit CCR5.CR
Data Sheet
163
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Table 43
Bit Functions in Periodical Performance Report1)
Bit Value
Interpretation
G1 = 1
number of CRC error events = 1
G2 = 1
1 < number of CRC error events ≤ 5
G3 = 1
5 < number of CRC error events ≤ 10
G4 = 1
10 < number of CRC error events ≤ 100
G5 = 1
100 < number of CRC error events ≤ 319
G6 = 1
number of CRC error events ≥ 320
SE = 1
Severely errored framing event ≥ 1 (FE shall be 0)
FE = 1
Frame synchronization bit error event ≥ 1 (SE shall be 0)
LV = 1
Line code violation event ≥ 1
SL = 1
Slip event ≥ 1
LB = 1
Payload loop-back activated
U1
not used (default value = 0)
U2
not used (default value = 0)
R
not used (default value = 0)
NmNi
One-second report modulo 4 counter
1)
according to ANSI T1.403
Data Sheet
164
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.5
System Interface in T1/J1 Mode
The FALC56 offers a flexible feature for system designers where for transmit and receive
direction different system clocks and system pulses are necessary. The interface to the
receive system highway is realized by two data buses, one for the data RDO and one for
the signaling data RSIG. The receive highway is clocked on pin SCLKR, while the
interface to the transmit system highway is independently clocked on pin SCLKX. The
frequency of these working clocks and the data rate of 2.048/4.096/8.192/16.384/1.544/
3.088/6.192/12.352 Mbit/s for the receive and transmit system interface is
programmable by SIC1.SSC1/0, SIC2.SSC2 and SIC1.SSD1, FMR1.SSD0. Selectable
system clock and data rates and their valid combinations are shown in the table below.
Table 44
System Clocking and Data Rates (T1/J1)
System Data Rate
Clock Rate
1.544/2.048
MHz
Clock Rate
3.088/4.096
MHz
Clock Rate
6.176/8.192
MHz
Clock Rate
12.352/
16.384 MHz
1.544/2.048 Mbit/s
x
x
x
x
3.088/4.096 Mbit/s
--
x
x
x
6.176/8.192 Mbit/s
--
--
x
x
12.352/16.384 Mbit/s
--
--
--
x
x = valid, -- = invalid
Generally the data or marker on the system interface are clocked off or latched on the
rising or falling edge (SIC3.RESR/X) of the SCLKR/X clock. Some clocking rates allow
transmission of time slots in different channel phases. Each channel phase which shall
be active on ports RDO, XDI, RP(A:D) and XP(A:D) is programmable by bit
SIC2.SICS(2:0), the remaining channel phases are cleared or ignored.
The signals on pin SYPR in combination with the assigned time slot offset in register RC0
and RC1 define the beginning of a frame on the receive system highway. The signal on
pin SYPX or XMFS together with the assigned time slot offset in register XC0 and XC1
define the beginning of a frame on the transmit system highway.
Adjusting the frame begin (time slot 0, bit 0) relative to SYPR/X or XMFS is possible in
the range of 0 to 125 µs. The minimum shift of varying the time slot 0 begin can be
programmed between 1 bit and 1/8 bit depending of the system clocking and data rate,
e.g. with a clocking/data rate of 2.048 MHz shifting is done bit by bit, while running the
FALC56 with 16.384 MHz and 2.048 Mbit/s data rate it is done by 1/8 bit.
A receive frame marker RFM can be activated during any bit position of the entire frame.
Programming is done with registers RC1/0. The pin function RFM is selected by
PC(4:1).RPC(2:0) = 001. The RFM selection disables the internal time slot assigner, no
offset programming is performed. The receive frame marker is active high for one 1.544/
Data Sheet
165
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
2.048 MHz cycle and is clocked off with the rising or falling edge of the clock which is in/
output on port SCLKR (see SIC3.RESX/R).
SCLKR
DCO-R
RSIGM
Receive
Signaling
Buffer
RSIG
RMFB
Receive
Elastic
Buffer
RFM
RP(A...D)
DLR
FREEZE
RFSP
SYPR
Receive
Backplane
DCO-R
BYP
Receive
Data
Receive
Jitter
Attenuator
Receive
Clock
RDO
DCO-R
SCLKX
XLT
Transmit
Signaling
Buffer
XSIG
SYPX
XP(A...D)
XMFS
Transmit
Backplane
Transmit
Elastic
Buffer
TCLK
XSIGM
XMFB
DLX
XCLK
Transmit
Data
Transmit
Clock
Figure 54
Data Sheet
BYP
PLB
XDI
Transmit
Jitter
Attenuator
TCLK
RCLK
F0118
System Interface (T1/J1)
166
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.5.1
Receive System Interface (T1/J1)
RDO
FRAME 1 FRAME 2 FRAME 3
~~ ~~
(e.g. F12 Frame Format)
FRAME 11 FRAME 12 FRAME 1 FRAME 2
~ ~
RMFB
SYPR
SYPR
Trigger
Edge1)
Sample
Edge
SCLKR
8.192 MHz
T
Programmable via RC0/1
SCLKR
1.544 MHz
TS0
RDO/RSIG
Bit 255
2 Mbit/s Data Rate
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 0
RDO/RSIG
4 Mbit/s Data Rate
(SCLKR = 8.192 MHz)
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
Bit 255
RDO/RSIG
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
4 Mbit/s Data Rate
(SCLKR = 8.192 MHz)
4 Mbit Interface
RFM
marks any
bit position
2 Mbit Interface
2 Mbit Interface
Receive Frame Marker
RCO/1
4 Mbit Interface
RSIGM
Time-Slot Marker
RTR1...4
marks any
Time-Slot
Sample Edge
T
Programmable via RC0/1
RDO
1.544 Mbit/s Data Rate
(SCLKR = 1.544 MHz)
Bit 192
FDL
Bit 1
Bit 2
Bit 3
Bit 4
DLR
DL Bit Marker
1.544 Mbit Interface
1)
only falling trigger edge shown, depending on Bit SIC3.RESR
Figure 55
Data Sheet
ITD10949
Receive System Interface Clocking (T1/J1)
167
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.5.1.1
Receive Offset Programming
Depending on the selection of the synchronization signals (SYPR or RFM), different
calculation formulas are used to define the position of the synchronization pulses. These
formulas are given below, see Figure 56 to Figure 59 for explanation. The pulse length
of SYPR and RFM is always the basic T1/J1 bit width (648 ns) in 1.544-MHz mode or
the E1 bit width (488 ns) in 2.048-MHz mode.
This chapter describes the system highway operation in 1.544-MHz mode only. If the
system highway is operated in 2.048-MHz mode, the description given in
Chapter 4.5.1.1 on page 106 applies.
SYPR Offset Calculation
T:
Time between beginning of SYPR pulse and beginning of next frame
(time slot 0, bit 0), measured in number of SCLKR clock intervals
maximum delay: Tmax = (193 × SC/SD) - 1
SD:
Basic data rate; 1.544 Mbit/s
SC:
System clock rate; 1.544, 3.088, 6.176, or 12.352 MHz
X:
Programming value to be written to registers RC0 and RC1 (see page 359).
0 ≤ T ≤ 4:
X = 4 - T + (7 × SC/SD)
5 ≤ T ≤ Tmax: X = (200 × SC/SD) + 4 - T
RFM Offset Calculation
MP:
Marker position of RFM, counting in SCLKR clock cycles (0 = F-bit)
SC = 1.544 MHz:
SC = 3.088 MHz:
SC = 6.176 MHz:
SC = 12.352 MHz:
0 ≤ MP ≤ 192
0 ≤ MP ≤ 385
0 ≤ MP ≤ 771
0 ≤ MP ≤ 1543
SD:
Basic data rate; 1.544 Mbit/s
SC:
System clock rate; 1.544, 3.088, 6.176, or 12.352 MHz
X:
Programming value to be written to registers RC0 and RC1 (see page 359).
0
≤ MP ≤ 193 × (SC/SD) - 3: X = MP + 2 + (7 × SC/SD)
193 × (SC/SD) - 2 ≤ MP ≤ 193 × (SC/SD) - 1: X = MP + 2 - (186 × SC/SD)
Data Sheet
168
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
TS0
RDO
TS1
TS24
F123456 781234567
TS0
TS1
12345678F123456781234567 8
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
SYPR
T=0
T
SYPR
T
SYPR
F0222A
Figure 56
SYPR Offset Programming (1.544 Mbit/s, 1.544 MHz)
TS0
RDO (CP0)
RDO (CP1)
RDO (CP2)
RDO (CP3)
F
1
F
2
1
F
3
2
1
F
TS24
1
8
3
2
7
3
2
TS0
F
8
7
3
F
8
7
1
1
F
8
2
2
1
F
3
3
2
1
4
3
2
3
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
SYPR
T=0
T
SYPR
T
SYPR
F0222B
bit-interleaved (TS = time slot, CP = channel phase)
Figure 57
Data Sheet
SYPR Offset Programming (6.176 Mbit/s, 6.176 MHz)
169
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
TS0
RDO
TS24
F123456 781234567
TS0
TS1
12345678F123456781234567 8
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
RFM
BP = 0
RFM
BP = 12
RFM
BP = 188
(BP = bit position)
Figure 58
F0222C
RFM Offset Programming (1.544 Mbit/s, 1.544 MHz)
TS0
RDO (CP0)
RDO (CP1)
RDO (CP2)
RDO (CP3)
F
1
F
2
1
F
3
2
1
F
TS24
1
8
3
2
7
3
2
TS0
8
7
3
F
F
8
7
1
1
F
8
2
2
1
F
3
3
2
1
4
3
2
3
SCLKR
SIC3.RESR = 0
(falling edge)
SCLKR
SIC3.RESR = 1
(rising edge)
RFM
BP = 0
RFM
BP = 12
RFM
BP = 1020
Figure 59
Data Sheet
bit-interleaved (TS = time slot, CP = channel phase, BP = bit position)
F0222D
RFM Offset Programming (6.176 Mbit/s, 6.176 MHz)
170
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
125 µs
SYPR
SCLKR
T
TS31
RDO
45 67
RSIG
AB CD
TS1
TS0
TS2
TS3
TS4
F0 12 34 5 67 0 12 34 5 67 0 12 34 5 67
ABCD
ABCD
A BCD
FS/DLchannel
T
F
ABCD
Figure 60
0 12 3
ABCD
Idle-channel
= Time slot offset (RC0, RC1)
= FS/DL-bit
= Signaling bits for time slots 1...24,
time slot mapping according to channel translation mode 0
F0135
2.048 MHz Receive Signaling Highway (T1/J1)
FS/DL Time-Slot
MSB
1
2
3
4
5
6
7
LSB
8
FS/DL
FS/DL Data Bit
ITD06460
Figure 61
Data Sheet
Receive FS/DL-Bits in Time Slot 0 on RDO (T1/J1)
171
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
125 µs
SYPR
SCLKR
T
TS23
TS0
TS1
TS23
RDO
45 67F 01 2 34 56 7 01 23 4 56 7
RSIG
AB CD F
A BCD
A BCD
A BCD F
ESF
RSIG
ABAB F
ABAB
ABAB
ABABF
F12
T
F
ABCD, ABAB
Figure 62
5.5.2
0 1 23 45 6 7F
= Time slot offset (RC0, RC1)
= FS/DL-bit
= Signaling bits for time slots 1...23
F0134
1.544 MHz Receive Signaling Highway (T1/J1)
Transmit System Interface (T1/J1)
Compared to the receive paths the inverse functions are performed for the transmit
direction.
The interface to the transmit system highway is realized by two data buses, one for the
data XDI and one for the signaling data XSIG. The time slot assignment is equivalent to
the receive direction. All unequipped (idle) time slots are ignored.
Latching of data is controlled by the system clock (SCLKX or SCLKR) and the
synchronization pulse (SYPX/XMFS) in combination with the programmed offset values
for the transmit time slot/clock slot counters XC1/0. The frequency of the working clock
2.048/4.096/8.192/16.384 MHz or 1.544/3.088/6.176/12.352 MHz for the transmit
system interface is programmable by SIC1.SSC1/0 and SIC2.SSC2. Refer also
Table 44.
The received bit stream on ports XDI and XSIG can be multiplexed internally on a time
slot basis, if enabled by SIC3.TTRF = 1. The data received on port XSIG can be sampled
if the transmit signaling marker XSIGM is active high. Data on port XDI is sampled if
XSIGM is low for the corresponding time slot. Programming the XSIGM marker is done
with registers TTR(4:1).
Note: XSIG is required in the last frame of a multiframe only and ignored in all other
frames.
Data Sheet
172
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
XDI
FRAME1
FRAME2
FRAME3
FRAME12
FRAME1
FRAME2
FRAME3
XMFB
XMFS
SYPX
Bit 0 Sample Edge 1)
Trigger Edge
1)
SYPX
T 2)
SCLKX
XSIGM
Time Slot Marker
FDL
XDI
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
DLX
DL Bit Marker
1)
2)
Figure 63
Data Sheet
only falling edge mode shown
delay T is programmable by XC0/1;
F0005
Transmit System Clocking: 1.544 MHz (T1/J1)
173
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
XDI
FRAME1
FRAME2
FRAME3
FRAME12
FRAME1
FRAME2
FRAME3
XMFS
SYPX
Bit 0 Sample Edge 1)
Trigger Edge
1)
SYPX
T 2)
SCLKX
XSIGM
Time-Slot Marker
XTR1...4
SIC2.SICS2-0=000(001)
XDI/XSIG
1
SIC2.SICS2-0=000
2
3
4
5
XDI/XSIG
6
7
8
1
SIC2.SICS2-0=001
2
3
4
5
6
7
8
DLX
DL-Bit Marker
SIC2.SICS2-0=000
DLX
DL-Bit Marker
SIC2.SICS2-0=001
1)
2)
Figure 64
Data Sheet
only falling edge mode shown
delay T is programmable by XC0/1;
F0006
Transmit System Clocking: 8.192 MHz/4.096 Mbit/s (T1/J1)
174
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
125 µs
SYPX
SCLKX
T
TS31
XDI
45 67
XSIG
AB CD
TS1
TS0
TS2
TS3
F0 12 34 5 67 0 12 34 5 67 0 12 34 5 67
ABCD
ABCD
A BCD
FS/DLchannel
T
F
ABCD
Figure 65
TS4
0 12 3
ABCD
Idle-channel
= Time slot offset (RC0, RC1)
= FS/DL-bit
= Signaling bits for time slots 1...24,
time slot mapping according to channel translation mode 0,
read only during last frame of a multiframe
F0136
2.048 MHz Transmit Signaling Clocking (T1/J1)
125 µs
SYPX
SCLKX
T
TS23
TS0
TS1
TS23
XDI
45 67F 01 2 34 56 7 01 23 4 56 7
XSIG
AB CD F
A BCD
A BCD
A BCD F
ESF
XSIG
ABAB F
ABAB
ABAB
ABABF
F12
T
F
ABCD
ABAB
Figure 66
Data Sheet
0 1 23 45 6 7F
= Time slot offset (RC0, RC1)
= FS/DL-bit
= ESF signaling bits for time slots 1...23
read only during last frame of a multiframe,
= F12 signaling bits for time slots 1...23
read only during last frame of a multiframe (bit positions 4/5)
F0137
1.544 MHz Transmit Signaling Highway (T1/J1)
175
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Multiframe n (e.g. F12)
Frame 2
Frame 3
Frame 12
~
~
Frame 1
~
~
RD0
XDI
RMFB
XMFB
RD0
XDI
24
FS/
1
DL
~
~
Signals in channel translation mode 0
2 3
4
5 6
7
8 9
19 20 21
22 23 24
FS/
DL
RSIGM1)
XSIGM
2
16 17 18 19 20 21 22 23 24
~
~
FS/
1
DL
RD0
XDI
~
~
Signals in channel translation mode 1
FS/
1
DL
RSIGM1)
XSIGM
1)
RSIGM and XSIGM are programed via registers RTR1... 4 / TTR1... 4 to mark only
channel 24
ITD06462
Figure 67
Signaling Marker for CAS/CAS-CC Applications (T1/J1)
Data Sheet
176
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
Multiframe n (e.g.F12)
Frame 6
Frame 12
~
~
~
~
RD0
XDI
~
~
Frame 2
~
~
Frame 1
RMFB
XMFB
RD0
XDI
24
FS/
1
DL
~
~
Signals in channel translation mode 0
2 3
4
5 6
7
8 9
19 20 21
22 23 24
FS/
DL
Signals in frames 6 and 12 of each multiframe
1)
~
~
RSIGM
XSIGM
2
16 17 18 19 20 21 22 23 24
~
~
FS/
1
DL
RD0
XDI
~
~
Signals in channel translation mode 1
FS/
1
DL
Signals in frames 6 and 12 of each multiframe
1)
Figure 68
Data Sheet
~
~
1)
RSIGM
XSIGM
RSIGM and XSIGM will mark the robbed bit positions if XCO.BRM is set high
ITD06463
Signaling Marker for CAS-BR Applications (T1/J1)
177
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
FS/DL data on system transmit highway (XDI), time slot 0:
FS/DL Time-Slot
MSB
1
2
3
4
5
6
7
LSB
8
FS/DL
FS/DL Data Bit
ITD06460
Figure 69
5.5.2.1
Transmit FS/DL Bits on XDI (T1/J1)
Transmit Offset Programming
The pulse length of SYPR and RFM is always the basic T1/J1 bit width (648 ns) in 1.544MHz mode or the E1 bit width (488 ns) in 2.048-MHz mode.
This chapter describes the system highway operation in 1.544-MHz mode only. If the
system highway is operated in 2.048-MHz mode, the description given in
Chapter 4.5.2.1 on page 111 applies.
SYPX Offset Calculation
T:
Time between the active edge of SCLKX after SYPX pulse begin and beginning
of the next frame (F-bit, channel phase 0), measured in number of SCLKX clock
intervals; maximum delay: Tmax = (200 × SC/BF) - (7 × SC/BF) - 1
BF:
Basic frequency; 1.544 Mbit/s
SC:
System clock rate; 1.544, 3.088, 6.176, or 12.352 MHz
X:
Programming value to be written to registers RC0 and RC1 (see page 356).
0 ≤ T ≤ 4:
X = 3 - T + (7 × SC/BF)
5 ≤ T ≤ Tmax: X = (200 × SC/BF) - T + 3
Data Sheet
178
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
TS1
XDI
TS2
TS24
F123456 781234567
TS1
TS2
12345678F123456781234567 8
SCLKX
SIC3.RESX = 1
(rising edge)
SCLKX
SIC3.RESX = 0
(falling edge)
SYPX
T=0
T
SYPX
T
SYPX
F0224A
Figure 70
SYPX Offset Programming (1.544 Mbit/s, 1.544 MHz)
TS1
XDI (CP0)
XDI (CP1)
XDI (CP2)
XDI (CP3)
F
1
F
2
1
F
3
2
1
F
TS24
1
8
3
2
7
3
2
TS1
F
8
7
3
F
8
7
1
1
F
8
2
2
1
F
3
3
2
1
4
3
2
3
SCLKX
SIC3.RESX = 1
(rising edge)
SCLKX
SIC3.RESX = 0
(falling edge)
SYPX
T=0
T
SYPX
T
SYPX
bit-interleaved (TS = time slot)
Figure 71
Data Sheet
F0224B
SYPX Offset Programming (6.176 Mbit/s, 6.176 MHz)
179
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.5.3
Time Slot Assigner (T1/J1)
HDLC channel 1 offers the flexibility to connect data during certain time slots, as defined
by registers RTR(4:1) and TTR(4:1), to the RFIFO and XFIFO, respectively. Any
combinations of time slots can be programmed for the receive and transmit directions. If
CCR1.EITS = 1 the selected time slots (RTR(4:1)) are stored in the RFIFO of the
signaling controller and the XFIFO contents is inserted into the transmit path as
controlled by registers TTR(4:1).
For HDLC channels 2 and 3, one out of 24 time slots can be selected for each channel,
but in common for transmit and receive direction.
Within selected time slots single bit positions can be masked to be used/not used for
HDLC transmission for all HDLC channels. Additionally, the use of even, odd or both
frames can be selected for each HDLC channel individually.
Table 45
Time Slot Assigner HDLC Channel 1 (T1/J1)
Receive
Time Slot
Register
Transmit
Time Slot
Register
Time Slots
Receive
Time Slot
Register
Transmit
Time Slot
Register
Time Slots
RTR 1.7
TTR 1.7
0
RTR 3.7
TTR 3.7
16
RTR 1.6
TTR 1.6
1
RTR 3.6
TTR 3.6
17
RTR 1.5
TTR 1.5
2
RTR 3.5
TTR 3.5
18
RTR 1.4
TTR 1.4
3
RTR 3.4
TTR 3.4
19
RTR 1.3
TTR 1.3
4
RTR 3.3
TTR 3.3
20
RTR 1.2
TTR 1.2
5
RTR 3.2
TTR 3.2
21
RTR 1.1
TTR 1.1
6
RTR 3.1
TTR 3.1
22
RTR 1.0
TTR 1.0
7
RTR 3.0
TTR 3.0
23
RTR 2.7
TTR 2.7
8
RTR 4.7
TTR 4.7
24
RTR 2.6
TTR 2.6
9
RTR 4.6
TTR 4.6
25
RTR 2.5
TTR 2.5
10
RTR 4.5
TTR 4.5
26
RTR 2.4
TTR 2.4
11
RTR 4.4
TTR 4.4
27
RTR 2.3
TTR 2.3
12
RTR 4.3
TTR 4.3
28
RTR 2.2
TTR 2.2
13
RTR 4.2
TTR 4.2
29
RTR 2.1
TTR 2.1
14
RTR 4.1
TTR 4.1
30
RTR 2.0
TTR 2.0
15
RTR 4.0
TTR 4.0
31
Data Sheet
180
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
The format for receive FS/DL data transmission in time slot 0 of the system interface is
as shown in Figure 63 below. In order to get an undisturbed reception even in the
asynchronous state bit FMR2.DAIS has to be set.
Data Sheet
181
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.6
Test Functions (T1/J1)
5.6.1
Pseudo-Random Binary Sequence Generation and Monitor
The FALC56 has the added ability to generate and monitor a 215-1 and 220-1 PseudoRandom Binary Sequences (PRBS). The generated PRBS pattern is transmitted to the
remote end on pins XL1/2 or XDOP/N and can be inverted optionally. Generating and
monitoring of PRBS pattern is done according to ITU-T O.151 and TR62411 with
maximum 14 consecutive zero restriction.
The PRBS monitor senses the PRBS pattern in the incoming data stream.
Synchronization is done on the inverted and non-inverted PRBS pattern. The current
synchronization status is reported in status and interrupt status registers. Enabled by bit
LCR1.EPRM each PRBS bit error increments an error counter (BEC). Synchronization
is reached within 400 ms with a probability of 99.9% and a bit error rate of up to 10-1.
The PRBS generator and monitor can be used to handle either a framed
(TPC0.FRA = 1) or an unframed (TPC0.FRA = 0) data stream.
5.6.2
Remote Loop
In the remote loop-back mode the clock and data recovered from the line inputs RL1/2
or RDIP/RDIN are routed back to the line outputs XL1/2 or XDOP/XDON through the
analog or digital transmitter. As in normal mode they are also processed by the
synchronizer and then sent to the system interface.The remote loop-back mode is
selected by setting the corresponding control bits LIM1.RL+JATT. Received data is
looped with or without use of the transmit jitter attenuator (FIFO).
RCLK
RL1
RL2
Clock +
Data
Recovery
Rec.
Framer
Elast.
Store
RDO
Trans.
Framer
Elast.
Store
XDI
FIFO
XL1
MUX
XL2
XCLK
Figure 72
Data Sheet
MUX
RCLK
DCO-R/X
ITS09750
Remote Loop (T1/J1)
182
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.6.3
Payload Loop-Back
To perform an effective circuit test a line loop is implemented.
If the payload loop-back (FMR2.PLB) is activated the received 192 bits of payload data
is looped back to the transmit direction. The framing bits, CRC6 and DL-bits are not
looped, if FMR4.TM = 0. They are originated by the FALC56 transmitter. If FMR4.TM = 1
the received FS/DL-bit is sent transparently back to the line interface. Following pins are
ignored: XDI, XSIG, TCLK, SCLKX, SYPX and XMFS. All the received data is processed
normally. With bit FMR2.SAIS an AIS can be sent to the system interface on pin RDO.
RCLK
RL1
RL2
AIS-GEN
MUX
Clock +
Data
Recovery
Rec.
Framer
Elast.
Store
RDO
SCLKR
XL1
XL2
Elast.
Store
Trans.
Framer
XDI
SCLKX
ITS09748
Figure 73
Data Sheet
Payload Loop (T1/J1)
183
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.6.4
Local Loop
The local loop-back mode, selected by LIM0.LL = 1, disconnects the receive lines RL1/
2 or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data
provided by system interface are routed through the analog receiver back to the system
interface. However, the bit stream is transmitted undisturbedly on the line. An AIS to the
distant end can be enabled by setting FMR1.XAIS without influencing the data looped
back to the system interface.
Note that enabling the local loop usually invokes an out of frame error until the receiver
resynchronizes to the new framing. The serial codes for transmitter and receiver have to
be identical.
RCLK
RL2
Clock +
Data
Recovery
Rec.
Framer
Elast.
Store
RDO
XL1
MUX
Trans.
Framer
Elast.
Store
XDI
RL1
XL2
AIS-GEN
ITS09749
Figure 74
Data Sheet
Local Loop (T1/J1)
184
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.6.5
Single Channel Loop-Back (loop-back of time slots)
The channel loop-back is selected by LOOP.ECLB = 1.
Each of the 24 time slots can be selected for loop-back from the system PCM input (XDI)
to the system PCM output (RDO). This loop-back is programmed for one time slot at a
time selected by register LOOP. During loop-back, an idle channel code programmed in
register IDLE is transmitted to the remote end in the corresponding PCM route time slot.
For the time slot test, sending sequences of test patterns like a 1-kHz check signal
should be avoided. Otherwise an increased occurrence of slips in the tested time slot
disturbs testing. These slips do not influence the other time slots and the function of the
receive memory. The usage of a quasi-static test pattern is recommended.
RCLK
RL1
RL2
XL1
XL2
Clock +
Data
Recovery
Trans.
Framer
Rec.
Framer
MUX
MUX
IDLE Code
Figure 75
Data Sheet
Elast.
Store
RDO
Elast.
Store
XDI
ITS09747
Channel Loop-Back (T1/J1)
185
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.6.6
Alarm Simulation (T1/J1)
Alarm simulation does not affect the normal operation of the device, i.e. all time slots
remain available for transmission. However, possible real alarm conditions are not
reported to the processor or to the remote end when the device is in the alarm simulation
mode.
The alarm simulation is initiated by setting the bit FMR0.SIM. The following alarms are
simulated:
•
•
•
•
•
•
•
•
Loss-Of-Signal (LOS, red alarm)
Alarm indication signal (AIS, blue alarm)
Loss of pulse frame
Remote alarm (yellow alarm) indication
Receive and transmit slip indication
Framing error counter
Code violation counter
CRC6 error counter
Some of the above indications are only simulated if the FALC56 is configured in a mode
where the alarm is applicable.
The alarm simulation is controlled by the value of the alarm simulation counter:
FRS2.ESC which is incremented by setting bit FMR0.SIM.
Clearing of alarm indications:
• Automatically for LOS, remote (yellow) alarm, AIS, and loss of synchronization and
• User controlled for slips by reading the corresponding interrupt status register ISR3.
• Error counter have to be cleared by reading the corresponding counter registers.
is only possible at defined counter steps of FRS2.ESC. For complete simulation
(FRS2.ESC = 0), eight simulation steps are necessary.
5.6.7
Single Bit Defect Insertion
Single bit defects can be inserted into the transmit data stream for the following
functions:
FAS defect, multiframe defect, CRC defect, CAS defect, PRBS defect and bipolar
violation.
Defect insertion is controlled by register IERR.
Data Sheet
186
2002-08-27
FALC56 V1.2
PEB 2256
Functional Description T1/J1
5.7
J1-Feature Overview
The Japanese J1 standard is very similar to the T1 standard, but differs in some details.
To support these differences easily, the following features are provided within the
FALC56:
• CRC6 generation and checking according to ITU-JT G.706
(CRC checksum calculation includes FS/DL-bits, see Chapter 5.2.6.3 on page 146)
• Remote alarm handling according to ITU-JT G.704
(remote alarm pattern in DL-channel is "1111111111111111", see Chapter 5.2.6.2 on
page 146)
• NTT synchronization requirements in ESF framing mode
• Pulse shaping according to JT G.704
• Receive input thresholds according to ITU-JT G.703
J1 mode is globally selected by setting RC0.SJR = 1 (see page 357). For specific J1
framer initialization see Table 55 on page 199.
No special pulse mask setting is required, the described T1-settings also fulfill the J1
requirements.
Data Sheet
187
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description E1
6
Operational Description E1
6.1
Operational Overview E1
The FALC56 can be operated in two modes, which are either E1 mode or T1/J1 mode.
The device is programmable via a microprocessor interface which enables byte or word
access to all control and status registers.
After reset the FALC56 must be initialized first. General guidelines for initialization are
described in Chapter 6.3.
The status registers are read-only and are updated continuously. Normally, the
processor reads the status registers periodically to analyze the alarm status and
signaling data.
6.2
Device Reset E1
The FALC56 is forced to the reset state if a low signal is input on pin RES for a minimum
period of 10 µs. During reset the FALC56 needs an active clock on pin MCLK. All output
stages are in a high-impedance state, all internal flip-flops are reset and most of the
control registers are initialized with default values.
SIgnals (for example RL1/2 receive line) should not be applied before the device is
powered up.
After reset the device is initialized to E1 operation.
6.3
Device Initialization in E1 Mode
After reset, the FALC56 is initialized for doubleframe format with register values listed in
the following table.
Table 46
Initial Values after Reset (E1)
Register
Reset Value Meaning
FMR0
00H
NRZ Coding, no alarm simulation.
FMR1
FMR2
00H
E1-doubleframe format, 2 Mbit/s system data rate, no AIS
transmission to remote end or system interface, payload
loop off.
SIC1
SIC2,
SIC3
00H
00H
00H
8.192 MHz system clocking rate, receive buffer 2 frames,
transmit buffer bypass, data sampled or transmitted on the
falling edge of SCLKR/X, automatic freeze signaling, data
is active in the first channel phase
Data Sheet
188
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description E1
Table 46
Initial Values after Reset (E1) (cont’d)
Register
Reset Value Meaning
LOOP
XSW
XSP
TSWM
00H
00H
00H
00H
Channel loop-back and single frame mode are disabled.
All bits of the transmitted service word are cleared. Spare
bit values are cleared.
No transparent mode active.
XC0
XC1
00H
9CH
The transmit clock offset is cleared.
The transmit time slot offset is cleared.
RC0
RC1
00H
9CH
The receive clock slot offset is cleared.
The receive time slot offset is cleared.
IDLE
ICB(4:1)
00H
00H
Idle channel code is cleared.
Normal operation (no “Idle Channel” selected).
LIM0
LIM1
PCD
PCR
00H
00H
00H
00H
Slave Mode, local loop off
Analog interface selected, remote loop off
Pulse count for LOS detection cleared
Pulse count for LOS recovery cleared
XPM(2:0)
40H, 03H, 7BH Transmit pulse mask (transmitter in tristate mode)
IMR(5:0)
FFH
All interrupts are disabled
RTR(4:1)
TTR(4:1)
TSS2
TSS3
all 00H
all 00H
00H
00H
No time slots selected
GCR
00H
Internal second timer, power on
CMR1
00H
RCLK output: DPLL clock, DCO-X enabled, DCO-X
internal reference clock
CMR2
00H
SCLKR selected, SCLKX selected, receive
synchronization pulse sourced by SYPR, transmit
synchronization pulse sourced by SYPX
PC(4:1)
00H, 00H
00H, 00H
Input function of ports RP(A to D): SYPR,
Input function of ports XP(A to D): SYPX
PC5
PC6
00H
00H
SCLKR, SCLKX, RCLK configured to inputs,
XMFS active low, CLK1 and CLK2 pin configuration
MODE
MODE2
MODE3
00H
00H
00H
Signaling controller disabled
Data Sheet
189
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description E1
Table 46
Initial Values after Reset (E1) (cont’d)
Register
Reset Value Meaning
RAH(2:1)
RAL(2:1)
FDH, FFH
FFH, FFH
Compare register for receive address cleared
GCM(6:1)
all 00H
Fixed clock mode selected (2.048 MHz on pin MCLK
required).
E1 Initialization
For a correct start up of the primary access interface a set of parameters specific to the
system and hardware environment must be programmed after reset goes inactive. Both
the basic and the operational parameters must be programmed before the activation
procedure of the PCM line starts. Such procedures are specified in ITU-T and ETSI
recommendations (e.g. fault conditions and consequent actions). Setting optional
parameters primarily makes sense when basic operation via the PCM line is guaranteed.
Table 47 gives an overview of the most important parameters in terms of signals and
control bits which are to be programmed in one of the above steps. The sequence is
recommended but not mandatory. Accordingly, parameters for the basic and operational
set up, for example, can be programmed simultaneously. The bit FMR1.PMOD should
always be kept low (otherwise T1/J1 mode is selected).
Table 47
Initialization Parameters (E1)
Basic Set Up
Master clocking mode
GCM(6:1) according to external MCLK
clock frequency
E1 mode select
FMR1.PMOD = 0
Specification of line interface and clock
generation
LIM0, LIM1, XPM(2:0)
Line interface coding
FMR0.XC(1:0), FMR0.RC(1:0)
Loss-of-signal detection/recovery
conditions
PCD, PCR, LIM1, LIM2
System clocking and data rate
SIC1.SSCC(1:0),
SIC1.SSD1,FMR1.SSD0
CMR2.IRSP/IRSC/IXSP/IXSC
Transmit offset counters
XC0.XCO, XC1.XTO
Receive offset counters
RC0.RCO, RC1.RTO
AIS to system interface
FMR2.DAIS/SAIS
Data Sheet
190
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description E1
Table 47
Initialization Parameters (E1) (cont’d)
Operational Set Up
Select framing
FMR2.RFS(1:0), FMR1.XFS
Framing additions
RC1.ASY4, RC1.SWD
Synchronization mode
FMR1.AFR, FMR2.ALMF
Signaling mode
XSP, XSW, FMR1.ENSA, XSA(8:4),
TSWM, MODE, CCR1, CCR2, RAH(2:1),
RAL(2:1)
Features like channel loop-back, idle channel activation, extensions for signaling
support, alarm simulation, etc. are activated later. Transmission of alarms (e.g. AIS,
remote alarm) and control of synchronization in connection with consequent actions to
remote end and internal system depend on the activation procedure selected.
Note: Read access to unused register addresses: value should be ignored.
Write access to unused register addresses: should be avoided, or set to “00” hex.
All control registers (except XFIFO, XS(16:1), CMDR, DEC) are of type Read/
Write.
Specific E1 Register Settings
The following is a suggestion for a basic initialization to meet most of the E1
requirements. Depending on different applications and requirement any other
initialization can be used.
Table 48
Line Interface Initialization (E1)
FMR0.XC0/
FMR0.RC0/
LIM1.DRS
FMR3.CMI
The FALC56 supports requirements for the analog line interface
as well as the digital line interface. For the analog line interface
the codes AMI and HDB3 are supported. For the digital line
interface modes (dual- or single-rail) the FALC56 supports AMI,
HDB3, CMI (with and without HDB3 precoding) and NRZ.
PCD = 0AH
LOS detection after 176 consecutive “zeros” (fulfills G.775).
PCR = 15H
LOS recovery after 22 “ones” in the PCD interval. (fulfills G.775).
LIM1.RIL(2:0) = 02H LOS threshold of 0.6 V (fulfills G.775).
E1 Framer Initialization
The selection of the following modes during the basic initialization supports the ETSI
requirements for E-Bit Access, remote alarm and synchronization (please refer also to
FALC56 driver code of the evaluation system EASY22554 and application notes) and
Data Sheet
191
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description E1
helps to reduce the software load. They are very helpful especially to meet requirements
as specified in ETS300 011.
Table 49
Framer Initialization (E1)
XSP.AXS = 1
ETS300 011 C4.x for instance requires the sending of E-Bits in
TS0 if CRC4 errors have been detected. By programming
XSP.AXS = 1 the submultiframe status is inserted automatically in
the next outgoing multiframe.
XSP.EBP = 1
If the FALC56 has reached asynchronous state the E-Bit is
cleared if XSP.EBP = 0 and set if XSP.EBP = 1. ETS300 011
requires that the E-Bit is set in asynchronous state.
FMR2.AXRA = 1
The transmission of RAI via the line interface is done automatically
by the FALC56 in case of loss of frame alignment (FRS0.LFA = 1).
If basic framing has been reinstalled RAI is automatically reset.
FMR2.FRS(2:1) =
10
FMR1.AFR = 1
In this mode a search of double framing is automatically restarted,
if no CRC4 multiframing is found within 8ms. Together with
FMR2.AXRA = 1 this mode is essential to meet ETS300 011 and
reduces the processor load heavily.
FMR2.ALMF = 1
The receiver initiates a new basic- and multiframing research if
more than 914 CRC4 errors have been detected in one second.
FMR2.FRS1/0 = 11 In the interworking mode the FALC56 stays in double framing
format if no multiframe pattern is found in a time interval of 400 ms.
This is also indicated by a 400 ms interrupt. Additionally the
extended interworking mode (FMR3.EXTIW = 1) will activate after
400 ms the remote alarm (FMR2.AXRA = 1) and will still search
the multiframing without switching completely to the double
framing. A complete resynchronization in an 8 ms interval is not
initiated.
Table 50
HDLC Controller Initialization (E1)
MODE = 88H
MODE2= 88H
MODE3= 88H
HDLC channel 1 receiver active, no address comparison.
HDLC channel 2 receiver active, no address comparison.
HDLC channel 2 receiver active, no address comparison.
CCR1 = 18H
Enable signaling via TS(31:0), interframe time fill with continuous
flags (channel 1).
Interframe time fill with continuous flags (channel 2).
Interframe time fill with continuous flags (channel 3).
CCR3= 08H
CCR4= 08H
Data Sheet
192
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description E1
Table 50
HDLC Controller Initialization (E1) (cont’d)
IMR0.RME = 0
IMR0.RPF = 0
IMR1.XPR = 0
IMR4.RME2=0
IMR4.RPF2=0
IMR5.XPR2=0
IMR5.RME3=0
IMR5.RPF3=0
IMR5.XPR3=0
Unmask interrupts for HDLC processor requests.
RTR3.TS16 = 1
TTR3.TS16 = 1
TSEO = 00H
Select TS16 for HDLC data reception and transmission.
TSBS1 = FFH
TSBS2= FFH
TSBS3= FFH
TSS2= 01H
TSS3= 02H
Table 51
Even and odd frames are used for HDLC reception and
transmission.
Select all bits of selected time slot (channel 1).
Select all bits of selected time slot (channel 2).
Select all bits of selected time slot (channel 3).
Select time slot 1 for HDLC channel 2.
Select time slot 2 for HDLC channel 3.
CAS-CC Initialization (E1)
XSP.CASEN = 1
CCR1.EITS = 0
Send CAS info stored in the XS(16:1) registers.
IMR0.CASC = 0
Enable interrupt with any data change in the RS(16:1) registers.
Note: After the device initialization a software reset should be executed by setting
of bits CMDR.XRES/RRES.
Data Sheet
193
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
7
Operational Description T1/J1
7.1
Operational Overview T1/J1
The FALC56 can be operated in two principle modes, which are either E1 mode or T1/
J1 mode.
The device is programmable via a microprocessor interface which enables byte or word
access to all control and status registers.
After reset the FALC56 must be initialized first. General guidelines for initialization are
described in Chapter 7.3
The status registers are read-only and are updated continuously. Normally, the
processor reads the status registers periodically to analyze the alarm status and
signaling data.
7.2
Device Reset T1/J1
The FALC56 is forced to the reset state if a low signal is input on pin RES for a minimum
period of 10 µs. During reset the FALC56 needs an active clock on pin MCLK. All output
stages are in a high-impedance state, all internal flip-flops are reset and most of the
control registers are initialized with default values.
SIgnals (for example RL1/2 receive line) should not be applied before the device is
powered up.
After reset the device is initialized to E1 operation.
7.3
Device Initialization in T1/J1 Mode
After reset, the FALC56 is initialized for E1 doubleframe format. To initialize T1/J1 mode,
bit FMR1.PMOD has to be set high. After the internal clocking is settled to T1/J1mode
(takes up to 20 µs), the following register values are initialized:
.
Table 52
Initial Values after reset and FMR1.PMOD = 1 (T1/J1)
Register
Initiated
Value
Meaning
FMR0
00H
NRZ coding, no alarm simulation
FMR1
FMR2
00H
00H
PCM24 mode, 2.048 Mbit/s system data rate, no AIS
transmission to remote end or system interface, payload
loop off, channel translation mode 0
Data Sheet
194
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
Table 52
Initial Values after reset and FMR1.PMOD = 1 (T1/J1) (cont’d)
Register
Initiated
Value
Meaning
SIC1
SIC2,
SIC3
00H
00H
00H
2.048 MHz system clocking rate, receive buffer 2 frames,
transmit buffer bypass, data sampled or transmitted on
the falling edge of SCLKR/X, automatic freeze signaling,
data is active in the first channel phase
LOOP
00H
loop-backs are disabled.
FMR4
FMR5
00H
00H
Remote alarm indication towards remote end is disabled.
LFA condition: 2 out of 4/5/6 framing bits, non-autosynchronization mode, F12 multiframing, internal bit
robbing access disabled
XC0
XC1
00H
9CH
The transmit clock slot offset is cleared.
The transmit time slot offset is cleared.
RC0
RC1
00H
9CH
The receive clock slot offset is cleared.
The receive time slot offset is cleared.
IDLE
ICB(3:1)
00H
00H
Idle channel code is cleared.
Normal operation (no “Idle Channels” selected).
CCB(3:1)
00H
Normal operation (no clear channel operation).
LIM0
LIM1
PCD
PCR
00H
00H
00H
00H
Slave mode, local loop off,
analog interface selected, remote loop off
pulse count for LOS detection cleared
pulse count for LOS recovery cleared
XPM(2:0)
40H,03H,7BH Transmit pulse mask (transmitter in tristate mode)
IMR(5:0)
FFH
All interrupts are disabled
GCR
00H
Internal second timer, power on
CMR1
00H
RCLK output: DPLL clock, DCO-X enabled, DCO-X
internal reference clock
CMR2
00H
SCLKR selected, SCLKX selected, receive
synchronization pulse sourced by SYPR, transmit
synchronization pulse sourced by SYPX
GPC1
00H
SEC port input active high
PC(4:1)
00H, 00H
00H, 00H
Input function of ports RP(A to D): SYPR,
Input function of ports XP(A to D): SYPX
PC5
PC6
00H
00H
SCLKR, SCLKX, RCLK configured to inputs,
XMFS active low, CLK1 and CLK2 pin configuration
Data Sheet
195
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
Table 52
Initial Values after reset and FMR1.PMOD = 1 (T1/J1) (cont’d)
Register
Initiated
Value
Meaning
MODE
MODE2
MODE3
00H
00H
00H
Signaling controller disabled
RAH(2:1)
RAL(2:1)
FDH, FFH
FFH, FFH
Compare register for receive address cleared
GCM(6:1)
all 00H
Fixed clock mode selected (1.544 MHz on pin MCLK
required).
RTR(4:1)
TTR(4:1)
TSS2
TSS3
all 00H
all 00H
00H
00H
No time slots selected
T1/J1 Initialization
For a correct start up of the primary access interface a set of parameters specific to the
system and hardware environment must be programmed after RES goes inactive (high).
Both the basic and the operational parameters must be programmed before the
activation procedure of the PCM line starts. Such procedures are specified in ITU-T
recommendations (e.g. fault conditions and consequent actions). Setting optional
parameters primarily makes sense when basic operation via the PCM line is guaranteed.
Table 53 gives an overview of the most important parameters in terms of signals and
control bits which are to be programmed in one of the above steps. The sequence is
recommended but not mandatory. Accordingly, parameters for the basic and operational
set up, for example, can be programmed simultaneously. The bit FMR1.PMOD must
always be kept high (otherwise E1 mode is selected). J1 mode is selected by additionally
setting RC0.SJR = 1.
Features like channel loop-back, idle channel activation, clear channel activation,
extensions for signaling support, alarm simulation, etc. are activated later. Transmission
of alarms (e.g. AIS, remote alarm) and control of synchronization in connection with
consequent actions to remote end and internal system depend on the activation
procedure selected.
Data Sheet
196
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
,
Table 53
Initialization Parameters (T1/J1)
Basic Set Up
T1
J1
Master clocking mode
GCM(6:1) according to external MCLK clock frequency
T1/J1 mode select
FMR1.PMOD = 1,
RC0.SJR = 0
Specification of line
interface and clock
generation
LIM0, LIM1, XPM(2:0)
Line interface coding
FMR0.XC(1:0), FMR0.RC(1:0)
Loss-of-signal detection/
recovery conditions
PCD, PCR, LIM1, LIM2
System clocking and data
rate
SIC1.SSC(1:0), SIC1.SSD1, FMR1.SSD0, CMR1.IRSP/
IRSC/IXSP/IXSC
Channel translation mode
FMR1.CTM
Transmit offset counters
XC0.XCO, XC1.XTO
Receive offset counters
RC0.RCO, RC1.RTO
AIS to system interface
FMR2.DAIS/SAIS
FMR1.PMOD = 1,
RC0.SJR = 1
Operational Set Up
Select framing
FMR4.FM(1:0)
Framing additions
FMR1.CRC, FMR0.SRAF
Synchronization mode
FMR4.AUTO, FMR4.SSC(1:0), FMR2.MCSP,
FMR2.SSP
Signaling mode
FMR5.EIBR, XC0.BRM, MODE, MODE2, MODE3,
CCR1, CCR2, RAH(2:1), RAL(2:1)
Note: Read access to unused register addresses: value should be ignored.
Write access to unused register addresses: should be avoided, or set to “00”hex.
All control registers (except XFIFO, XS(12:1), CMDR, DEC) are of type read/write
Data Sheet
197
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
Specific T1/J1 Initialization
The following is a suggestion for a basic initialization to meet most of the T1/J1
requirements. Depending on different applications and requirements any other
initialization can be used.
Table 54
Line Interface Initialization (T1/J1)
Register
Function
FMR0.XC0/1
FMR0.RC0/1
LIM1.DRS
CCB(3:1)
SIC3.CMI
The FALC56 supports requirements for the analog line interface
as well as the digital line interface. For the analog line interface the
codes AMI (with and without bit 7stuffing) and B8ZS are
supported. For the digital line interface modes (dual- or single-rail)
the FALC56 supports AMI (with and without bit 7 stuffing), B8ZS
(with and without B8ZS precoding) and NRZ.
PCD = 0AH
LOS detection after 176 consecutive “zeros” (fulfills G.775/
Telcordia (Bellcore)/AT&T)
PCR = 15H
LOS recovery after 22 “ones” in the PCD interval (fulfills G.775,
Bellcore/AT&T).
LIM1.RIL(2:0)
= 02H
LOS threshold of 0.6 V (fulfills G.775).
GCR.SCI = 1
Additional Recovery Interrupts. Help to meet alarm activation and
deactivation conditions in time.
LIM2.LOS1 = 1
Automatic pulse-density check on 15 consecutive zeros for LOS
recovery condition (Bellcore requirement)
Data Sheet
198
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
Table 55
Framer Initialization (T1/J1)
Register
Function
T1
J1
FMR4.SSC1/0
Selection of framing sync conditions
FMR4.FM1/0
Select framing format
FMR2.AXRA = 1
The transmission of RAI via the line interface is done automatically
by the FALC56 in case of Loss of Frame Alignment
(FRS0.LFA = 1). If framing has been reinstalled RAI is
automatically reset
FMR4.AUTO = 1
Automatic synchronization in case of definite framing candidate
(FRS0.FSRF).
In case of multiple framing candidates and CRC6 errors different
resynchronization conditions can be programmed via
FMR2.MCSP/SSP.
RCO.SJR1) = 1
FMR0.SRAF = 0
XSW.XRA = 1
Remote alarm handling via DLchannel according to ITU-T
JG.704 using pattern
"1111111111111111"
RCO.SJR = 0
CRC6 calculation without FS/
DL-bits
RCO.SJR = 1
FMR4.AUTO = 1
CRC6 calculation including FS/
DL-bits
Automatic synchronization in case of definite framing candidate
(FRS0.FSRF). In case of multiple framing candidates and CRC6
errors different resynchronization conditions can be programmed
via FMR2.MCSP/SSP.
FMR4.SSC1 = 1
FMR4.SSC0 = 1
FMR2.MCSP = 0
FMR2.SSP = 1
1)
Synchronization and
resynchronization conditions,
for details see register
description
Remote alarm handling and CRC6 calculation are commonly selected by RC0.SJR
Data Sheet
199
2002-08-27
FALC56 V1.2
PEB 2256
Operational Description T1/J1
Table 56
HDLC Controller Initialization (T1/J1)
MODE = 88H
MODE2= 88H
MODE3= 88H
HDLC channel 1 receiver active, no address comparison.
HDLC channel 2 receiver active, no address comparison.
HDLC channel 2 receiver active, no address comparison.
CCR1 = 18H
Enable signaling via TS(24:1), interframe time fill with continuous
flags (channel 1).
Interframe time fill with continuous flags (channel 2).
Interframe time fill with continuous flags (channel 3).
CCR3= 08H
CCR4= 08H
IMR0.RME = 0
IMR0.RPF = 0
IMR1.XPR = 0
IMR4.RME2=0
IMR4.RPF2=0
IMR5.XPR2=0
IMR5.RME3=0
IMR5.RPF3=0
IMR5.XPR3=0
Unmask interrupts for HDLC processor requests.
RTR4.0 = 1
TTR4.0 = 1
TSEO = 00H
Select time slot 24 for HDLC data reception and transmission.
Even and odd frames are used for HDLC reception and
transmission.
Select all bits of selected time slot (channel 1).
Select all bits of selected time slot (channel 2).
Select all bits of selected time slot (channel 3).
Select time slot 1 for HDLC channel 2.
Select time slot 2 for HDLC channel 3.
TSBS1 = FFH
TSBS2= FFH
TSBS3= FFH
TSS2= 01H
TSS3= 02H
Table 57
Initialization of the CAS-BR Controller (T1/J1)
FMR5.EIBR = 1
Enable CAS-BR Mode
Send CAS-BR information stored in XS(12:1)
IMR1.CASE = 0
IMR0.RSC = 0
Enable interrupts which indicate the access to the XS(12:1) CASBR registers and any data change in RS(12:1)
Note: After the device initialization a software reset should be executed by setting of bits
CMDR.XRES/RRES.
Data Sheet
200
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
8
Signaling Controller Operating Modes
The three HDLC controllers can be programmed to operate in various modes, which are
different in the treatment of the HDLC frame in receive direction. Thus, the receive data
flow and the address recognition features can be performed in a very flexible way, to
satisfy almost any practical requirements.
There are 4 different operating modes which can be set via the mode registers (MODE,
MODE2 and MODE3).
If not mentioned otherwise, all functions described for HDLC channel 1 apply to channel
2 and 3 as well.
8.1
HDLC Mode
All frames with valid addresses are forwarded directly via the RFIFO to the system
memory.
Depending on the selected address mode, the FALC56 can perform a 1- or 2-byte
address recognition (MODE.MDS0).
If a 2-byte address field is selected, the high address byte is compared to the fixed value
FEH or FCH (group address) as well as with two individually programmable values in
RAH1 and RAH2 registers. According to the ISDN LAPD protocol, bit 1 of the high byte
address is interpreted as command/response bit (C/R) and is excluded from the address
comparison.
Similarly, two compare values can be programmed in special registers (RAL1, RAL2) for
the low address byte. A valid address is recognized in case the high and low byte of the
address field correspond to one of the compare values. Thus, the FALC56 can be called
(addressed) with 6 different address combinations. HDLC frames with address fields that
do not match any of the address combinations, are ignored by the FALC56.
In case of a 1-byte address, RAL1 and RAL2 are used as compare registers. The HDLC
control field, data in the I-field and an additional status byte are temporarily stored in the
RFIFO. Additional information can also be read from a special register (RSIS).
As defined by the HDLC protocol, the FALC56 performs the zero bit insertion/deletion
(bit stuffing) in the transmit/receive data stream automatically. That means, it is
guaranteed that at least one “0” will appear after 5 consecutive “1”s.
8.1.1
Non-Auto Mode
(MODE.MDS(2:1) = 01; MODE2.MDS22..21=01; MODE3.MDS32..31=01)
Characteristics: address recognition, flag- and CRC generation/check, bit stuffing
All frames with valid addresses are forwarded directly via the RFIFO (RFIFO2, RFIFO3)
to the system memory.
Data Sheet
201
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
8.1.2
Transparent Mode 1
(MODE.MDS(2:0) = 101; MODE2.MDS2(2:0)=101; MODE3.MDS3(2:0)=101)
Characteristics: address recognition, flag- and CRC generation/check, bit stuffing
Only the high byte of a 2-byte address field is compared to registers RAH(2:1). The
whole frame excluding the first address byte is stored in RFIFO (RFIFO2, RFIFO3).
8.1.3
Transparent Mode 0
(MODE.MDS(2:0) = 100; MODE2.MDS2(2:0)=100; MODE3.MDS3(2:0)=100)
Characteristics: flag- and CRC generation/check, bit stuffing
No address recognition is performed and each frame is stored in the RFIFO (RFIFO2,
RFIFO3).
8.1.4
SS7 Support
SS7 protocol is supported for channel 1 only by means of several hardware features as
described in Chapter 4.1.14.2 on page 74 and Chapter 5.1.14.2 on page 135.
8.1.5
Receive Data Flow
The following figure gives an overview of the management of the received HDLC frames
in the different operating modes.
Data Sheet
202
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
FLAG
ADDR
CTRL
DATA
CRC
FLAG
MODE.MDS(2:0)
1)
RAH1,2 RAL1,2
RFIFO
0
1
1
Non-Auto/16
2)
2)
RSIS
RAH1,2
1)
X
RFIFO
0
1
0
Non-Auto/8
2)
RSIS
1)
RAH1,2
RFIFO
1
0
1 Transparent 1
2)
RSIS
1)
RFIFO
1
0
0 Transparent 0
RSIS
Description of Symbols:
compared with register
stored in FIFO or register
In case of 8-bit address the
control field starts here
1) CRC is optionally stored in RFIFO of HDLC channel 1, 2 or 3 if
CCR2.RCRC = 1 (channel 1)
CCR3.RCRC2 = 1 (channel 2)
CCR4.RCRC3 = 1 (channel 3)
2) Address is optionally stored in RFIFO of HDLC channel 1, 2 or 3 if
CCR2.RADD = 1 (channel 1)
CCR3.RADD2 = 1 (channel 2)
CCR4.RADD3 = 1 (channel 3)
F0235
Figure 76
Data Sheet
HDLC Receive Data Flow
203
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
8.1.6
Transmit Data Flow
The frames can be transmitted as shown below.
FLAG
ADDR
CTRL
ADDRESS
CONTROL
Transmit
HDLC
Frame
(XHF)
Ι
CRC
DATA
FLAG
CHECKRAM
XFIFO
ITD06456
Figure 77
HDLC Transmit Data Flow
Transmitting a HDLC frame via register CMDR.XTF (or CMDR2.XTF2/CMDR3.XTF3 for
channel 2/3), the address, the control fields and the data field have to be entered in the
XFIFO (XFIFO2, XFIFO3).
If CCR2.XCRC (or CCR3.XCRC2/CCR4.XCRC3 for channel 2/3) is set, the CRC
checksum will not be generated internally. The checksum has to be provided via the
transmit FIFO (XFIFO, XFIFO2, XFIFO3) as the last two bytes. The transmitted frame is
closed automatically with a closing flag only.
The FALC56 does not check whether the length of the frame, i.e. the number of bytes to
be transmitted makes sense or not.
8.2
Extended Transparent Mode
Characteristics: fully transparent
In no HDLC mode, fully transparent data transmission/reception without HDLC framing
is performed, i.e. without flag generation/recognition, CRC generation/check, or bit
stuffing. This feature can be profitably used e.g. for:
• Specific protocol variations
• Transmission of a BOM frame (channel 1 only)
• Test purposes
Data transmission is always performed out of the XFIFO (XFIFO2, XFIFO3). In
transparent mode, the receive data is shifted into the RFIFO (RFIFO2, RFIFO3).
Note: If a 1-byte frame is sent in extended transparent mode, in addition to interrupt
ISR1.XPR (transmit pool ready) the interrupt ISR1.XDU (transmit buffer underrun)
is set and XFIFO is blocked.
Data Sheet
204
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
8.3
Signaling Controller Functions
8.3.1
Transparent Transmission and Reception
When programmed in the extended transparent mode via the MODE registers
(MODE.MDS(2:0) = 111, MODE2.MDS2(2:0)=111, MODE3.MDS3(2:0)=111), the
FALC56 performs fully transparent data transmission and reception without HDLC
framing, i.e. without
• flag insertion and deletion
• CRC generation and checking
• Bit stuffing
In order to enable fully transparent data transfer, bit MODE.HRAC (MODE2.HRAC2,
MODE3.HRAC3) has to be set.
Received data is always shifted into RFIFO (RFIFO2, RFIFO3).
Data transmission is always performed out of XFIFO (XFIFO2, XFIFO3) by shifting the
contents of XFIFO into the outgoing data stream directly. Transmission is initiated by
setting CMDR.XTF (04H). A synchronization byte FFH is sent automatically before the
first byte of the XFIFO is transmitted.
Cyclic Transmission (fully transparent)
If the extended transparent mode is selected, the FALC56 supports the continuous
transmission of the contents of the transmit FIFOs.
After having written 1 to 32 bytes to XFIFO (XFIFO2, XFIFO3), the command
XREP&XTF (CMDR = 00100100 = 24H) forces the FALC56 to transmit the data stored
in XFIFO to the remote end repeatedly.
Note: The cyclic transmission continues until a reset command (CMDR.SRES) is issued
or with resetting of CMDR.XREP, after which continuous “1”s are transmitted.
During cyclic transmission the XREP-bit has to be set with every write operation
to CMDR.
The same handling applies to CMDR2 and CMDR3 for HDLC channels 2 an 3.
8.3.2
CRC on/off Features
As an option in HDLC mode the internal handling of the received and transmitted CRC
checksum can be influenced via control bits CCR2.RCRC and CCR2.XCRC (channel 2:
CCR3.RCRC2, CCR3.XCRC2, channel 3: CCR4.RCRC3, CCR4.XCRC3).
• Receive Direction
The received CRC checksum is always assumed to be in the 2 last bytes of a frame
(CRC-ITU), immediately preceding a closing flag. If CCR2.RCRC is set, the received
CRC checksum is written to RFIFO where it precedes the frame status byte (contents of
register RSIS). The received CRC checksum is additionally checked for correctness. If
Data Sheet
205
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
HDLC mode is selected, the limits for “Valid Frame” check are modified (refer to
description of bit RSIS.VFR).
• Transmit Direction
If CCR2.XCRC is set, the CRC checksum is not generated internally. The checksum has
to be provided via the transmit FIFO (XFIFO) as the last two bytes. The transmitted frame
is closed automatically by a closing flag only.
The FALC56 does not check whether the length of the frame, i.e. the number of bytes to
be transmitted is valid or not.
8.3.3
Receive Address Pushed to RFIFO
The address field of received frames can be pushed to the receive FIFOs (first one or
two bytes of a frame). This function is used together with extended address recognition.
It is enabled by setting control bit CCR2.RADD (CCR3.RADD2, CCR4.RADD3).
8.3.4
HDLC Data Transmission
In transmit direction 2 × 32 byte FIFO buffers are provided for each HDLC channel. After
checking the XFIFO status by polling bit SIS.XFW (SIS2.XFW2, SIS3,XFW3) or after an
interrupt ISR1.XPR (ISR5.XPR2, ISR5.XPR3, Transmit Pool Ready), up to 32 bytes can
be entered by the CPU to the XFIFOs.
The transmission of a frame can be started by issuing a XTF or XHF command via the
command registers. If the transmit command does not include an end of message
indication (CMDR.XME, CMDR3.XME2, CMDR4.XME3), the FALC56 will repeatedly
request for the next data block by means of an XPR interrupt as soon as no more than
32 bytes are stored in the XFIFO, i.e. a 32-byte pool is accessible to the CPU.
This process is repeated until the CPU indicates the end of message by XME command,
after which frame transmission is finished correctly by appending the CRC and closing
flag sequence. Consecutive frames can share a flag, or can be transmitted as back-toback frames, if service of the XFIFOs is fast enough.
In case no more data is available in the XFIFOs prior to the arrival of XME, the
transmission of the frame is terminated with an abort sequence and the CPU is notified
by interrupt ISR1.XDU (ISR4.XDU2, ISR5.XDU3). The frame can be aborted by software
using CMDR.SRES (CMDR3.SRES2, CMDR4.SRES3).
The data transmission sequence, from the CPU’s point of view, is outlined in Figure 78.
Data Sheet
206
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
START
N
XPR Interrupt, or
XFW Bit in SIS Register = 1
Transmit
Pool Ready
?
Y
Write Data
(up to 32 bytes)
to XFIFO
Command
XTF/XHF
End of
Message
?
N
Y
Command
XTF/XHF + XME
END
Figure 78
ITD08565
Interrupt Driven Data Transmission (flow diagram)
The activities at both serial and CPU interface during frame transmission (supposed
frame length = 70 bytes) shown in Figure 79.
Transmit Frame (70 bytes)
32
System
Interface
32
6
FALC R
CPU
Interface
XPR
WR XFIFO
32 bytes
XHF
WR XFIFO
32 bytes
Command
XHF
XPR
XHF + XME XPR
WR XFIFO
6 bytes
ALLS
ITD10971
Figure 79
Data Sheet
Interrupt Driven Transmission Example
207
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
8.3.5
HDLC Data Reception
2×32 byte FIFO buffers are also provided in receive direction for each HDLC channel.
There are different interrupt indications concerned with the reception of data:
• RPF (RPF2, RPF3, receive pool full) interrupt, indicating that a 32-byte block of data
can be read from RFIFO (RFIFO2, RFIFO3) and the received message is not yet
complete.
• RME (RME2, RME3, receive message end) interrupt, indicating that the reception of
one message is completed.
The following figure gives an example of a reception sequence, assuming that a “long”
frame (66 bytes) followed by two short frames (6 bytes each) are received.
System
Interface
Receive Frame 1 (66 bytes) RF2 RF3
2 6 6
32
32
FALC R
RMC
RPF
RMC
RME
RMC
RME
RMC
RD6 bytes
RD Status
RD6 bytes
RD Status
RD2 bytes
RD RFIFO
32 bytes
RD RFIFO
32 bytes
RPF
RD Status
CPU
Interface
RMC
RME
ITD10972
Figure 80
8.3.6
Interrupt Driven Reception Sequence Example
Sa-bit Access (E1)
The FALC56 supports the Sa-bit signaling of time slot 0 of every other frame as follows:
• Access via registers RSW/XSW
• Access via registers RSA(8:4)/XSA(8:4)
capable of storing the information for a complete multiframe
• Access via the 64 byte deep receive/transmit FIFO of the integrated signaling
controller (HDLC channel 1 only). This Sa-bit access gives the opportunity to transmit/
receive a transparent bit stream as well as HDLC frames where the signaling
controller automatically processes the HDLC protocol. Enabling is done by setting of
bit CCR1.EITS and resetting of registers TTR(4:1), RTR(4:1) and FMR1.ENSA.
Data Sheet
208
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
Data written to the XFIFO will be transmitted subsequently in the Sa-bit positions
defined by register XC0.SA8E to SA84E and the corresponding bits of
TSWM.TSA(8:4). Any combination of Sa-bits can be selected. After the data has been
sent out completely an “all ones” or Flags (CCR1.ITF) is transmitted. The continuous
transmission of a transparent bit stream, which is stored in the XFIFO, can be
enabled.
With the setting of bit MODE.HRAC the received Sa-bits can be forwarded to the
receive FIFO.
The access to and from the FIFOs is supported by ISR0.RME/RPF and ISR1.XPR/
ALS.
8.3.7
Bit Oriented Message Mode (T1/J1)
The FALC56 supports signaling and maintenance functions for T1/J1 primary rate
Interfaces using the Extended Super Frame format. The HDLC channel 1 of the device
supports the DL-channel protocol for ESF format according to T1.403-1989 ANSI or to
AT&T TR54016 specification. The HDLC and Bit Oriented Message (BOM) -Receiver
can be switched on/off independently. If the FALC56 is used for HDLC formats only, the
BOM receiver has to be switched off. If HDLC and BOM receiver has been switched on
(MODE.HRAC/BRAC), an automatic switching between HDLC and BOM mode is
enabled. Storing of received DL-bit information in the RFIFO of the signaling controller
and transmitting the XFIFO contents in the DL-bit positions is enabled by CCR1.EDLX/
EITS = 10. After hardware-reset (pin RES low) or software-reset (CMDR.RRES = 1) the
FALC56 operates in HDLC mode. If eight or more consecutive ones are detected, the
BOM mode is entered. Upon detection of a flag in the data stream, the FALC56 switches
back to HDLC mode. Operating in BOM mode, the FALC56 is able to receive an HDLC
frame immediately, i.e. without any preceding flags.
In BOM mode, the following byte format is assumed (the left most bit is received first;
111111110xxxxxx0).
The FALC56 uses the FFH byte for synchronization, the next byte is stored in RFIFO (first
bit received: LSB) if it starts and ends with a “0”. Bytes starting and ending with a “1” are
not stored. If there are no 8 consecutive ones detected within 32 bits, an interrupt is
generated. However, byte sampling is not stopped.
Data Sheet
209
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
Byte sampling in BOM Mode (T1/J1)
a)
1111 1111 1111 0011 0100 1111 1111 0011 0100 1110 1111 0011 0100 1101 1111
sync
not stored
new sync
1.byte
stored
1.corrupted
sync
2.byte
stored
2.corrupted
sync
corrupted
sync
b)
1111 1111 0111 0110 1101 1111 0111 0110 1111 1111 0111 0110 0111 1111
sync
1.byte
stored
1.corrupted
byte
2.byte
stored
2.sync
3.byte
stored
3.corrupted
sync
Three different BOM reception modes can be programmed (CCR1.BRM, CCR2.RBFE).
10 byte packets: CCR1.BRM = 0
After storing 10 bytes in RFIFO the receive status byte marking a BOM frame
(RSIS.HFR) is added as the eleventh byte and an interrupt (ISR0.RME) is generated.
The sampling of data bytes continues and interrupts are generated every 10 bytes until
an HDLC flag is detected.
Continuous reception: CCR1.BRM = 1
Interrupts are generated every 32 (16, 4, 2) bytes. After detecting an HDLC flag, byte
sampling is stopped, the receive status byte is stored in RFIFO and an RME interrupt is
generated.
Reception with enabled BOM filter: CCR2.RBFE = 1
The BOM receiver will only accept BOM frames after detecting 7 out of 10 equal BOM
pattern. The BOM pattern is stored in the RFIFO adding a receive status byte, marking
a BOM frame (RSIS.HFR) and generating an interrupt status ISR0.RME. The current
state of the BOM receiver is indicated in register SIS.IVB. When the valid BOM pattern
disappears an interrupt ISR0.BIV is generated.
The user can switch between these modes at any time. Byte sampling can be stopped
by deactivating the BOM receiver (MODE.BRAC). In this case the receive status byte is
added, an interrupt is generated and HDLC mode is entered. Whether the FALC56
operates in HDLC or BOM mode are checked by reading the signaling status register
(SIS.BOM).
Data Sheet
210
2002-08-27
FALC56 V1.2
PEB 2256
Signaling Controller Operating Modes
8.3.8
Data Link Access in ESF/F72 Format (T1/J1)
The FALC56 supports the DL-channel protocol using the ESF or F72 (SLC96) format as
follows (HDLC channel 1 only):
• Sampling of DL-bits is done on a multiframe basis and stored in the registers
RDL(3:1). A receive multiframe begin interrupt is provided to read the received data
DL-bits. The contents of registers XDL(3:1) is subsequently sent out on the transmit
multiframe basis if it is enabled via FMR1.EDL. A transmit multiframe begin interrupt
requests for writing new information to the DL-bit registers.
• If enabled via CCR1.EDLX/EITS = 10, the DL-bit information is stored in the receive
FIFO of the signaling controller. The DL-bits stored in the XFIFO are inserted into the
outgoing data stream. If CCR1.EDLX is cleared, a HDLC frame or a transparent frame
can be sent or received via the RFIFO/XFIFO.
Data Sheet
211
2002-08-27
FALC56 V1.2
PEB 2256
Register Description
Due to the different device function is E1 and T1/J1 mode, several registers and register
bits have dedicated functions according to the selected operation mode.
To maintain easy readability this chapter is divided into separate E1 and T1/J1 sections.
Please choose the correct description according to your application (E1 or T1/J1).
Data Sheet
212
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
9
E1 Registers
9.1
E1 Control Register Addresses
Table 58
E1 Control Register Address Arrangement
Address
Register
Type
Comment
Page
00
XFIFO
W
Transmit FIFO
217
01
XFIFO
W
Transmit FIFO
217
02
CMDR
W
Command Register
217
03
MODE
R/W
Mode Register
219
04
RAH1
R/W
Receive Address High 1
220
05
RAH2
R/W
Receive Address High 2
220
06
RAL1
R/W
Receive Address Low 1
220
07
RAL2
R/W
Receive Address Low 2
220
08
IPC
R/W
Interrupt Port Configuration
221
09
CCR1
R/W
Common Configuration Register 1 221
0A
CCR2
R/W
Common Configuration Register 2 224
0C
RTR1
R/W
Receive Time Slot Register 1
225
0D
RTR2
R/W
Receive Time Slot Register 2
225
0E
RTR3
R/W
Receive Time Slot Register 3
225
0F
RTR4
R/W
Receive Time Slot Register 4
225
10
TTR1
R/W
Transmit Time Slot Register 1
226
11
TTR2
R/W
Transmit Time Slot Register 2
226
12
TTR3
R/W
Transmit Time Slot Register 3
226
13
TTR4
R/W
Transmit Time Slot Register 4
226
14
IMR0
R/W
Interrupt Mask Register 0
227
15
IMR1
R/W
Interrupt Mask Register 1
227
16
IMR2
R/W
Interrupt Mask Register 2
227
17
IMR3
R/W
Interrupt Mask Register 3
227
18
IMR4
R/W
Interrupt Mask Register 4
227
19
IMR5
R/W
Interrupt Mask Register 5
227
1B
IERR
R/W
Single Bit Error Insertion Register 227
1C
FMR0
R/W
Framer Mode Register 0
Data Sheet
213
228
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Table 58
E1 Control Register Address Arrangement (cont’d)
Address
Register
Type
Comment
Page
1D
FMR1
R/W
Framer Mode Register 1
230
1E
FMR2
R/W
Framer Mode Register 2
232
1F
LOOP
R/W
Channel Loop-Back
233
20
XSW
R/W
Transmit Service Word
234
21
XSP
R/W
Transmit Spare Bits
235
22
XC0
R/W
Transmit Control 0
236
23
XC1
R/W
Transmit Control 1
237
24
RC0
R/W
Receive Control 0
238
25
RC1
R/W
Receive Control 1
239
26
XPM0
R/W
Transmit Pulse Mask 0
241
27
XPM1
R/W
Transmit Pulse Mask 1
241
28
XPM2
R/W
Transmit Pulse Mask 2
241
29
TSWM
R/W
Transparent Service Word Mask
242
2B
IDLE
R/W
Idle Channel Code
243
2C
XSA4
R/W
Transmit Sa4-Bit Register
244
2D
XSA5
R/W
Transmit Sa5-Bit Register
244
2E
XSA6
R/W
Transmit Sa6-Bit Register
244
2F
XSA7
R/W
Transmit Sa7-Bit Register
244
30
XSA8
R/W
Transmit Sa8-Bit Register
244
31
FMR3
R/W
Framer Mode Register 3
245
32
ICB1
R/W
Idle Channel Register 1
246
33
ICB2
R/W
Idle Channel Register 2
246
34
ICB3
R/W
Idle Channel Register 3
246
35
ICB4
R/W
Idle Channel Register 4
246
36
LIM0
R/W
Line Interface Mode 0
247
37
LIM1
R/W
Line Interface Mode 1
248
38
PCD
R/W
Pulse Count Detection
249
39
PCR
R/W
Pulse Count Recovery
250
3A
LIM2
R/W
Line Interface Mode 2
250
3B
LCR1
R/W
Loop Code Register 1
251
Data Sheet
214
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Table 58
E1 Control Register Address Arrangement (cont’d)
Address
Register
Type
Comment
Page
3C
LCR2
R/W
Loop Code Register 2
253
3D
LCR3
R/W
Loop Code Register 3
253
3E
SIC1
R/W
System Interface Control 1
254
3F
SIC2
R/W
System Interface Control 2
255
40
SIC3
R/W
System Interface Control 3
256
44
CMR1
R/W
Clock Mode Register 1
258
45
CMR2
R/W
Clock Mode Register 2
259
46
GCR
R/W
Global Configuration Register
261
47
ESM
R/W
Errored Second Mask
262
60
DEC
W
Disable Error Counter
262
70
XS1
W
Transmit CAS Register 1
263
71
XS2
W
Transmit CAS Register 2
263
72
XS3
W
Transmit CAS Register 3
263
73
XS4
W
Transmit CAS Register 4
263
74
XS5
W
Transmit CAS Register 5
263
75
XS6
W
Transmit CAS Register 6
263
76
XS7
W
Transmit CAS Register 7
263
77
XS8
W
Transmit CAS Register 8
263
78
XS9
W
Transmit CAS Register 9
263
79
XS10
W
Transmit CAS Register 10
263
7A
XS11
W
Transmit CAS Register 11
263
7B
XS12
W
Transmit CAS Register 12
263
7C
XS13
W
Transmit CAS Register 13
263
7D
XS14
W
Transmit CAS Register 14
263
7E
XS15
W
Transmit CAS Register 15
263
7F
XS16
W
Transmit CAS Register 16
263
80
PC1
R/W
Port Configuration 1
264
81
PC2
R/W
Port Configuration 2
264
82
PC3
R/W
Port Configuration 3
264
83
PC4
R/W
Port Configuration 4
264
Data Sheet
215
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Table 58
E1 Control Register Address Arrangement (cont’d)
Address
Register
Type
Comment
Page
84
PC5
R/W
Port Configuration 5
266
85
GPC1
R/W
Global Port Configuration 1
267
86
PC6
R/W
Port Configuration 6
268
87
CMDR2
W
Command Register 2
269
88
CMDR3
W
Command Register 3
269
89
CMDR4
W
Command Register 4
270
8B
CCR3
R/W
Common Control Register 3
271
8C
CCR4
R/W
Common Control Register 4
273
8D
CCR5
R/W
Common Control Register 5
274
8E
MODE2
R/W
Mode Register 2
275
8F
MODE3
R/W
Mode Register 3
276
92
GCM1
R/W
Global Counter Mode 1
277
93
GCM2
R/W
Global Counter Mode 2
277
94
GCM3
R/W
Global Counter Mode 3
278
95
GCM4
R/W
Global Counter Mode 4
278
96
GCM5
R/W
Global Counter Mode 5
279
97
GCM6
R/W
Global Counter Mode 6
279
9C
XFIFO2
W
Transmit FIFO 2
281
9D
XFIFO2
W
Transmit FIFO 2
281
9E
XFIFO3
W
Transmit FIFO 3
281
9F
XFIFO3
W
Transmit FIFO 3
281
A0
TSEO
R/W
Time Slot Even/Odd Select
281
A1
TSBS1
R/W
Time Slot Bit Select 1
282
A2
TSBS2
R/W
Time Slot Bit Select 2
283
A3
TSBS3
R/W
Time Slot Bit Select 3
283
A4
TSS2
R/W
Time Slot Select 2
284
A5
TSS3
R/W
Time Slot Select 3
284
A8
TPC0
R/W
Test Pattern Control Register 0
285
After reset all control registers except the XFIFO and XS(16:1) are initialized to defined
values. Unused bits have to be cleared (logical "0").
Data Sheet
216
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
9.2
Detailed Description of E1 Control Registers
Transmit FIFO - HDLC Channel 1 (Write)
7
0
XFIFO
XF7
XF0
(00)
XFIFO
XF15
XF8
(01)
Writing data to XFIFO of HDLC channel 1 can be done in 8-bit (byte) or 16-bit (word)
access. The LSB is transmitted first.
Up to 32 bytes/16 words of transmit data can be written to the XFIFO following a XPR
interrupt.
Command Register (Write)
Value after reset: 00H
7
CMDR
RMC
RMC
0
RRES
XREP
XRES
XHF
XTF
XME
SRES
(02)
Receive Message Complete - HDLC Channel 1
Confirmation from CPU to FALC56 that the current frame or data
block has been fetched following a RPF or RME interrupt, thus the
occupied space in the RFIFO can be released. If RMC is given while
RFIFO is already cleared, the next incoming data block is cleared
instantly, although interrupts are generated.
RRES
Receiver Reset
The receive line interface except the clock and data recovery unit
(DPLL), the receive framer, the one-second timer and the receive
signaling controller are reset. However the contents of the control
registers is not deleted.
XREP
Transmission Repeat - HDLC Channel 1
If XREP is set together with XTF (write 24H to CMDR), the FALC56
repeatedly transmits the contents of the XFIFO (1 to 32 bytes) without
HDLC framing fully transparently, i.e. without flag, CRC.
The cyclic transmission is stopped with a SRES command or by
resetting XREP.
Note:During cyclic transmission the XREP-bit has to be set with
every write operation to CMDR.
Data Sheet
217
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XRES
Transmitter Reset
The transmit framer and transmit line interface excluding the system
clock generator and the pulse shaper are reset. However the contents
of the control registers is not deleted.
XHF
Transmit HDLC Frame - HDLC Channel 1
After having written up to 32 bytes to the XFIFO, this command
initiates the transmission of a HDLC frame.
XTF
Transmit Transparent Frame - HDLC Channel 1
Initiates the transmission of a transparent frame without HDLC
framing.
XME
Transmit Message End - HDLC Channel 1
Indicates that the data block written last to the transmit FIFO
completes the current frame. The FALC56 can terminate the
transmission operation properly by appending the CRC and the
closing flag sequence to the data.
SRES
Signaling Transmitter Reset - HDLC Channel 1
The transmitter of the signaling controller is reset. XFIFO is cleared of
any data and an abort sequence (seven 1's) followed by interframe
time fill is transmitted. In response to SRES a XPR interrupt is
generated.
This command can be used by the CPU to abort a frame currently in
transmission.
Note: The maximum time between writing to the CMDR register and
the execution of the command takes 2.5 periods of the current
system data rate. Therefore, if the CPU operates with a very
high clock rate in comparison with the FALC56's clock, it is
recommended that bit SIS.CEC should be checked before
writing to the CMDR register to avoid any loss of commands.
Note: If SCLKX is used to clock the transmission path, commands to
the HDLC transmitter should only be sent while this clock is
available. If SCLKX is missing, the command register is
blocked after an HDLC command is given.
Data Sheet
218
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Mode Register (Read/Write)
Value after reset: 00H
7
MODE
MDS(2:0)
MDS2
0
MDS1
MDS0
HRAC
DIV
(03)
Mode Select - HDLC Channel 1
The operating mode of the HDLC controller is selected.
000 = Reserved
001 = Signaling System 7 (SS7) support1)
010 = One-byte address comparison mode (RAL1,2)
011 = Two-byte address comparison mode (RAH1,2 and RAL1,2)
100 = No address comparison
101 = One-byte address comparison mode (RAH1,2)
110 = Reserved
111 = No HDLC framing mode
HRAC
Receiver Active - HDLC Channel 1
Switches the HDLC receiver to operational or inoperational state.
DIV
0=
Receiver inactive
1=
Receiver active
Data Inversion - HDLC Channel 1
Setting this bit inverts the internal generated HDLC channel 1 data
stream.
1)
0=
Normal operation, HDLC data stream not inverted
1=
HDLC data stream inverted
CCR2.RADD must be set, if SS7 mode is selected
Data Sheet
219
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Address Byte High Register 1 (Read/Write)
Value after reset: FDH
7
0
RAH1
0
(04)
In operating modes that provide high byte address recognition, the high byte of the
received address is compared to the individually programmable values in RAH1 and
RAH2. The address registers are used by all HDLC channels in common.
RAH1
Value of the First Individual High Address Byte
Bit 1 (C/R-bit) is excluded from address comparison.
Receive Address Byte High Register 2 (Read/Write)
Value after reset: FFH
7
0
RAH2
(05)
RAH2
Value of Second Individual High Address Byte
Receive Address Byte Low Register 1 (Read/Write)
Value after reset: FFH
7
0
RAL1
(06)
RAL1
Value of First Individual Low Address Byte
Receive Address Byte Low Register 2 (Read/Write)
Value after reset: FFH
7
0
RAL2
RAL2
Data Sheet
(07)
Value of the second individually programmable low address
byte.
220
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Interrupt Port Configuration (Read/Write)
Value after reset: 00H
7
0
IPC
SSYF
IC1
IC0
(08)
Note: Unused bits have to be cleared.
SSYF
Select SYNC Frequency
Only applicable in master mode (LIM0.MAS = 1) and bit CMR2.DCF
is cleared.
0=
1=
IC0, IC1
Reference clock on port SYNC is 2.048 MHz
Reference clock on port SYNC is 8 kHz
Interrupt Port Configuration
These bits define the function of the interrupt output stage (pin INT):
IC1
IC0
Function
X
0
1
0
1
1
Open drain output
Push/pull output, active low
Push/pull output, active high
Common Configuration Register 1 (Read/Write)
Value after reset: 00H
7
CCR1
XTS16RA
0
XTS16RA
CASM
EITS
ITF
XMFA
RFT1
RFT0
(09)
Send Remote Alarm in Time Slot 16
Sending of remote alarm in time slot 16 towards remote end by setting
bit "Y" in the CAS multiframe alignment word. If XS registers are used
for CAS (instead of XSIG), bit XS1.2 ("Y") is logically ored with
XTS16RA. If XSIG is used for CAS, Y-data received on XSIG is
logically ored with XTS16RA.
CASM
Data Sheet
0=
No remote alarm insertion
1=
Remote alarm insertion
CAS Synchronization Mode
221
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Determines the synchronization mode of the channel associated
signaling multiframe alignment.
EITS
ITF
0=
Synchronization is done in accordance to ITU-T G. 732
1=
Synchronization is established when two consecutively correct
multiframe alignment pattern are found.
Enable Internal Time Slot 0 to 31 Signaling
0=
Internal signaling in time slots 0 to 31 defined by registers
RTR(4:1) or TTR(4:1) is disabled.
1=
Internal signaling in time slots 0 to 31 defined by registers
RTR(4:1) or TTR(4:1) is enabled.
Interframe Time Fill
Determines the idle (= no data to be sent) state of the transmit data
coming from the signaling controller.
XMFA
0=
Continuous logical "1" is output
1=
Continuous flag sequences are output ("01111110" bit
patterns)
Transmit Multiframe Aligned
Determines the synchronization between the framer and the
corresponding signaling controller.
0=
The contents of the XFIFO is transmitted without multiframe
alignment.
1=
The contents of the XFIFO is transmitted multiframe aligned.
The first byte in XFIFO is transmitted in the first time slot
selected by TTR(4:1) and so on.
After reception of a complete multiframe in the time slot mode
(RTR(4:1)) an ISR0.RME interrupt is generated, if no HDLC
mode is enabled
In Sa-bit access mode XMFA is not valid.
Note: During the transmission of the XFIFO content, the SYPX or
XMFS interval time should not be changed, otherwise the
XFIFO data has to be retransmitted.
Data Sheet
222
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RFT(1:0)
RFIFO Threshold Level - HDLC Channel 1
The size of the accessible part of RFIFO can be determined by
programming these bits. The number of valid bytes after a RPF
interrupt is given in the following table:
RFT1
RFT0
Size of Accessible Part of RFIFO
0
0
1
1
0
1
0
1
32 bytes (reset value)
16 bytes
4 bytes
2 bytes
The value of RFT1, 0 can be changed dynamically.
– If reception is not running or
– after the current data block has been read, but before the
command CMDR.RMC is issued (interrupt controlled data transfer).
Note: It is seen that changing the value of RFT1, 0 is possible even
during the reception of one frame. The total length of the
received frame can be always read directly in RBCL, RBCH
after a RPF interrupt, except when the threshold is increased
during reception of that frame. The real length can then be
inferred by noting which bit positions in RBCL are reset by a
RMC command (see table below):
Data Sheet
RFT1
RFT0
Bit Positions in RBCL Reset by a
CMDR.RMC Command
0
0
1
1
0
1
0
1
RBC(4:0)
RBC(3:0)
RBC(1:0)
RBC0
223
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Common Configuration Register 2 (Read/Write)
Value after reset: 00H
7
CCR2
0
RADD
RCRC
XCRC
(0A)
Note: Unused bits have to be cleared.
RADD
Receive Address Pushed to RFIFO - HDLC Channel 1
If this bit is set, the received HDLC address information (1 or 2 bytes,
depending on the address mode selected by MODE.MDS0) is pushed
to RFIFO. This function is applicable in non-auto mode and
transparent mode 1.
RADD must be set, if SS7 mode is selected.
RCRC
Receive CRC on/off - HDLC Channel 1
Only applicable in non-auto mode.
If this bit is set, the received CRC checksum is written to RFIFO
(CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in
the received frame, is followed by the status information byte
(contents of register RSIS). The received CRC checksum is
additionally checked for correctness. If non-auto mode is selected,
the limits for “valid frame” check are modified (refer to RSIS.VFR).
XCRC
Transmit CRC on/off - HDLC Channel 1
If this bit is set, the CRC checksum is not generated internally. It has
to be written to the transmit FIFO as the last two bytes. The
transmitted frame is closed automatically with a closing flag.
Note: The FALC56 does not check whether the length of the frame,
i.e. the number of bytes to be transmitted makes sense or not.
Data Sheet
224
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Time Slot Register 1 to 4 (Read/Write)
Value after reset: 00H, 00H, 00H, 00H
7
0
RTR1
TS0
TS1
TS2
TS3
TS4
TS5
TS6
TS7
(0C)
RTR2
TS8
TS9
TS10
TS11
TS12
TS13
TS14
TS15
(0D)
RTR3
TS16
TS17
TS18
TS19
TS20
TS21
TS22
TS23
(0E)
RTR4
TS24
TS25
TS26
TS27
TS28
TS29
TS30
TS31
(0F)
TS(31:0)
Time Slot
These bits define the received time slots on the system highway port
RDO to be extracted to RFIFO and marked. Additionally these
registers control the RSIGM marker which can be forced high during
the corresponding time slots independently of bit CCR1.EITS.
A one in the RTR(4:1) bits samples the corresponding time slots and
send their data to the RFIFO of the signaling controller if bit
CCR1.EITS is set.
Assignments:
TS0 →Time slot 0
...
TS31 → Time slot 31
0 =The corresponding time slot is not extracted and stored into
the RFIFO.
1=
Data Sheet
The contents of the selected time slot is stored in the RFIFO.
Although the idle time slots can be selected. This function is
activated, if bit CCR1.EITS is set.
The corresponding time slot is forced high on marker pin
RSIGM.
225
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit Time Slot Register 1 to 4 (Read/Write)
Value after reset: 00H, 00H, 00H, 00H
7
0
TTR1
TS0
TS1
TS2
TS3
TS4
TS5
TS6
TS7
(10)
TTR2
TS8
TS9
TS10
TS11
TS12
TS13
TS14
TS15
(11)
TTR3
TS16
TS17
TS18
TS19
TS20
TS21
TS22
TS23
(12)
TTR4
TS24
TS25
TS26
TS27
TS28
TS29
TS30
TS31
(13)
TS(31:0)
Time Slot
These bits define the transmit time slots on the system highway to be
inserted. Additionally these registers control the XSIGM marker which
can be forced high during the corresponding time slots independently
of bit CCR1.EITS.
A one in the TTR(4:1) bits inserts the corresponding time slot sourced
by the XFIFO in the data received on pin XDI, if bit CCR1.EITS is set.
If SIC3.TTRF is set and CCR1.EITS is cleared insertion of data
received on port XSIG is controlled by this registers.
Assignments:
TS0 →Time slot 0
...
TS31 → Time slot 31
Data Sheet
0=
The selected time slot is not inserted into the outgoing data
stream.
1=
The contents of the selected time slot is inserted into the
outgoing data stream from XFIFO. This function is active only if
bit CCR1.EITS is set.
The corresponding time slot is forced high on marker pin
XSIGM.
226
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Interrupt Mask Register 0 to 5 (Read/Write)
Value after reset: FFH, FFH, FFH, FFH, FFH
7
0
IMR0
RME
RFS
T8MS
RMB
CASC
CRC4
SA6SC
RPF
(14)
IMR1
LLBSC
RDO
ALLS
XDU
XMB
SUEX
XLSC
XPR
(15)
IMR2
FAR
LFA
MFAR
T400MS
AIS
LOS
RAR
RA
(16)
IMR3
ES
SEC
LMFA16
AIS16
RA16
RSN
RSP
(17)
IMR4
XSP
XSN
RME2
RFS2
RDO2
ALLS2
XDU2
RPF2
(18)
IMR5
XPR2
XPR3
RME3
RFS3
RDO3
ALLS3
XDU3
RPF3
(19)
IMR(5:0)
Interrupt Mask Register
Each interrupt source can generate an interrupt signal on port INT
(characteristics of the output stage are defined by register IPC). A “1”
in a bit position of IMR(5:0) sets the mask active for the interrupt
status in ISR(5:0). Masked interrupt statuses neither generate a
signal on INT, nor are they visible in register GIS. Moreover, they are
- not displayed in the interrupt status register if bit GCR.VIS is cleared
- displayed in the interrupt status register if bit GCR.VIS is set
Note: After reset, all interrupts are disabled.
Single Bit Defect Insertion Register (Read/Write)
Value after reset: 00H
IERR
IFASE
IMFE
ICRCE
ICASE
IPE
IBV
(1B)
After setting the corresponding bit, the selected defect is inserted into the transmit data
stream at the next possible position. After defect insertion is completed, the bit is reset
automatically.
IFASE
Insert single FAS defect
IMFE
Insert single multiframe defect
ICRCE
Insert single CRC defect
ICASE
Insert single CAS defect
IPE
Insert single PRBS defect
Data Sheet
227
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
IBV
Insert bipolar violation
Note:Except for CRC defects, CRC checksum calculation is done
after defect insertion.
Framer Mode Register 0 (Read/Write)
Value after reset: 00H
7
FMR0
XC(1:0)
XC1
0
XC0
RC1
RC0
EXZE
ALM
FRS
SIM
(1C)
Transmit Code
Serial line code for the transmitter, independent of the receiver.
00 = NRZ (optical interface)
01 = CMI (1T2B+HDB3), (optical interface)
10 = AMI (ternary or digital dual-rail interface)
11 = HDB3 Code (ternary or digital dual-rail interface)
After changing XC(1:0), a transmitter software reset is required
(CMDR.XRES = 1).
RC(1:0)
Receive Code
Serial line code for the receiver, independent of the transmitter.
00 = NRZ (optical interface)
01 = CMI (1T2B+HDB3), (optical interface)
10 = AMI (ternary or digital dual-rail interface)
11 = HDB3 Code (ternary or digital dual-rail interface)
After changing RC(1:0), a receiver software reset is required
(CMDR.RRES = 1).
EXZE
Extended HDB3 Error Detection
Selects error detection mode.
ALM
0=
Only double violations are detected.
1=
Extended code violation detection: 0000 strings are detected
additionally. Incrementing of the code violation counter CVC is
done after receiving four zeros. Errors are indicated by
FRS1.EXZD = 1.
Alarm Mode
Selects the AIS alarm detection mode.
Data Sheet
228
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
FRS
0=
The AIS alarm is detected according to ETS300233.
Detection: An AIS alarm is detected if the incoming data stream
contains less than 3 zeros within a period of 512 bits and a loss
of frame alignment is indicated.
Recovery: The alarm is cleared if 3 or more zeros within 512
bits are detected or the FAS word is found.
1=
The AIS alarm is detected according to ITU-T G.775
Detection: An AIS alarm is detected if the incoming data stream
contains less than 3 zeros in each doubleframe period of two
consecutive doubleframe periods (1024 bits).
Recovery: The alarm is cleared if 3 or more zeros are detected
within two consecutive doubleframe periods.
Force Resynchronization
A transition from low to high initiates a resynchronization procedure
of the pulse frame and the CRC-multiframe (if enabled by bit
FMR2.RFS1) starting directly after the old framing candidate.
SIM
Alarm Simulation
0=
Normal operation.
1=
Initiates internal error simulation of AIS, loss-of-signal, loss of
synchronization, remote alarm, slip, framing errors, CRC
errors, and code violations. The error counters FEC, CVC,
CEC1 are incremented.
SIM has to be held stable at high or low level for at least one receive
clock period before changing it again.
Data Sheet
229
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Framer Mode Register 1 (Read/Write)
Value after reset: 00H
7
FMR1
MFCS
MFCS
0
AFR
ENSA
PMOD
XFS
ECM
SSD0
XAIS
(1D)
is
selected
Multiframe Force Resynchronization
Only
valid
if
CRC
(FMR2.RFS(1:0) = 10).
multiframe
format
A transition from low to high initiates the resynchronization procedure
for CRC-multiframe alignment without influencing doubleframe
synchronous state. In case, “Automatic Force Resynchronization”
(FMR1.AFR) is enabled and multiframe alignment cannot be
regained, a new search of doubleframe (and CRC multiframe) is
automatically initiated.
AFR
Automatic Force Resynchronization
Only
valid
if
CRC
(FMR2.RFS(1:0) = 10).
multiframe
format
is
selected
If this bit is set, a search of doubleframe alignment is automatically
initiated if two multiframe patterns with a distance of n × 2 ms have
not been found within a time interval of 8 ms after doubleframe
alignment has been regained or command FMR1.MFCS has been
issued.
ENSA
Enable Sa-Bit Access through Register XSA4-8
Only applicable if FMR1.XFS is set.
PMOD
0=
Normal operation. The Sa-bit information is taken from bits
XSW.XY(4:0) and written to bits RSW.RY(4:0).
1=
Sa-bit register access. The Sa-bit information is taken from the
registers XSA(8:4). In addition, the received information is
written to registers RSA(8:4). Transmitting of the contents of
registers XSA(8:4) is disabled if one of time slot 0 transparent
modes is enabled (XSP.TT0 or TSWM.SA(8:4)).
PCM Mode
For E1 application this bit must be set low. Switching from E1 to T1 or
vice versa the device needs up to 20 µs to settle up to the internal
clocking.
0=
Data Sheet
PCM 30 or E1 mode.
230
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
1=
XFS
PCM 24 or T1/J1 mode (see RC0.SJR for T1/J1 selection).
Transmit Framing Select
Selection of the transmit framing format can be done independently
of the receive framing format.
ECM
0=
Doubleframe format enabled.
1=
CRC4-multiframe format enabled.
Error Counter Mode
The function of the error counters is determined by this bit.
SSD0
0=
Before reading an error counter the corresponding bit in the
Disable Error Counter register (DEC) has to be set. In 8 bit
access the low byte of the error counter should always be read
before the high byte. The error counters are reset with the rising
edge of the corresponding bits in the DEC register.
1=
Every second the error counter is latched and then
automatically reset. The latched error counter state should be
read within the next second. Reading the error counter during
updating should be avoided (do not access an error counter
within 1 µs after the one-second interrupt occurs).
Select System Data Rate 0
FMR1.SSD0 and SIC1.SSD1 define the data rate on the system
highway. Programming is done with SSD1/SSD0 in the following
table.
00 = 2.048 Mbit/s
01 = 4.096 Mbit/s
10 = 8.192 Mbit/s
11 = 16.384 Mbit/s
XAIS
Transmit AIS Towards Remote End
Sends AIS on ports XL1, XL2, XOID towards the remote end. The
outgoing data stream which can be looped back through the local loop
to the system interface is not affected.
Data Sheet
231
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Framer Mode Register 2 (Read/Write)
Value after reset: 00H
7
FMR2
RFS(1:0)
RFS1
0
RFS0
RTM
DAIS
SAIS
PLB
AXRA
ALMF
(1E)
Receive Framing Select
00 = Doubleframe format
01 = Doubleframe format
10 = CRC4 Multiframe format
11 = CRC4 Multiframe format with modified CRC4 Multiframe
alignment algorithm (Interworking according to ITU-T G.706
Annex B). Setting of FMR3.EXTIW changes the reaction after
the 400 ms time-out.
RTM
Receive Transparent Mode
Setting this bit disconnects control of the internal elastic store from the
receiver. The elastic store is now in a “free running” mode without any
possibility to actualize the time slot assignment to a new frame
position in case of resynchronization of the receiver. This function can
be used together with the “disable AIS to system interface” feature
(FMR2.DAIS) to realize undisturbed transparent reception.
This bit should be enabled in case of unframed data reception mode.
DAIS
SAIS
Disable AIS to System Interface
0=
AIS is automatically inserted into the data stream to RDO if
FALC56 is in asynchronous state.
1=
Automatic AIS insertion is disabled. Furthermore, AIS insertion
can be initiated by programming bit FMR2.SAIS.
Send AIS Towards System Interface
Sends AIS on output RDO towards system interface. This function is
not influenced by bit FMR2.DAIS.
PLB
Data Sheet
Payload Loop-Back
0=
Normal operation. Payload loop is disabled.
1=
The payload loop-back loops the data stream from the receiver
section back to transmitter section. Looped data is output on
pin RDO. Data received on port XDI, XSIG, SYPX and XMFS is
ignored. With XSP.TT0 = 1 time slot 0 is also looped back. If
XSP.TT0 = 0 time slot 0 is generated internally. AIS is sent
232
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
immediately on port RDO by setting the FMR2.SAIS bit. It is
recommended to write the actual value of XC1 into this register
once again, because a write access to register XC1 sets the
read/write pointer of the transmit elastic buffer into its optimal
position to ensure a maximum wander compensation (the write
operation forces a slip).
AXRA
Automatic Transmit Remote Alarm
ALMF
0=
Normal operation
1=
The remote alarm bit is set automatically in the outgoing data
stream if the receiver is in asynchronous state (FRS0.LFA bit is
set). In synchronous state the remote alarm bit is reset.
Additionally in multiframe format FMR2.RFS1 = 1 and
FMR3.EXTIW = 1 and the 400 ms time-out has elapsed, the
remote alarm bit is active in the outgoing data stream. In
multiframe synchronous state the outgoing remote alarm bit is
cleared.
Automatic Loss of Multiframe
0=
Normal operation
1=
The receiver searches a new basic- and multiframing if more
than 914 CRC errors have been detected in a time interval of
one second. The internal 914 CRC error counter is reset if the
multiframe synchronization is found. Incrementing the counter
is only enabled in the multiframe synchronous state.
Channel Loop-Back (Read/Write)
Value after reset: 00H
7
0
LOOP
ECLB
CLA(4:0)
ECLB
CLA4
CLA3
CLA2
CLA1
CLA0
(1F)
Enable Channel Loop-Back
0=
Disables the channel loop-back.
1=
Enables the channel loop-back selected by this register.
Channel Address For Loop-Back
CLA = 0 to 31 selects the channel.
During looped back the contents of the assigned outgoing channel on
ports XL1/XDOP/XOID and XL2/XDON is equal to the idle channel
code programmed at register IDLE.
Data Sheet
233
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit Service Word Pulseframe (Read/Write)
Value after reset: 00H
7
XSW
XSIS
XSIS
0
XTM
XRA
XY0
XY1
XY2
XY3
XY4
(20)
Spare Bit For International Use
First bit of the service word. Only significant in doubleframe format. If
not used, this bit should be fixed to "1". If one of the time slot 0
transparent modes is enabled (bit XSP.TT0, or TSWM.TSIS), bit
XSW.XSIS is ignored.
XTM
XRA
XY(4:0)
Transmit Transparent Mode
0=
Ports SYPX/XMFS define the frame/multiframe begin on the
transmit system highway. The transmitter is usually
synchronized on this externally sourced frame boundary and
generates the FAS-bits according to this framing. Any change
of the transmit time slot assignment subsequently produces a
change of the FAS-bit positions.
1=
Disconnects the control of the transmit system interface from
the transmitter. The transmitter is now in a free running mode
without any possibility to actualize the multiframe position. The
framing (FAS-bits) generated by the transmitter is not
“disturbed” (in case of changing the transmit time slot
assignment) by the transmit system highway unless register
XC1 is written. Useful in loop-timed applications. For proper
operation
the
transmit
elastic
buffer
(2
frames,
SIC1.XBS(1:0) = 10) has to be enabled.
Transmit Remote Alarm
0=
Normal operation.
1=
Sends remote alarm towards remote end by setting bit 3 of the
service word. If time slot 0 transparent mode is enabled by bit
XSP.TT0 or TSWM.TRA bit is set, bit XSW.XRA is ignored.
Spare Bits For National Use (Y-Bits, Sn-Bits, Sa-Bits)
These bits are inserted in the service word of every other pulseframe
if Sa-bit register access is disabled (FMR1.ENSA = 0). If not used,
they should be fixed to “1”.
If one of the time slot 0 transparent modes is enabled (bit XSP.TT0 or
TSWM.TSA(8:4)), bits XSW.XY(4:0) are ignored.
Data Sheet
234
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit Spare Bits (Read/Write)
Value after reset: 00H
7
0
XSP
CASEN
CASEN
Channel Associated Signaling Enable
TT0
EBP
AXS
TT0
EBP
AXS
XSIF
XS13
XS15
(21)
0=
Normal operation.
1=
A one in this bit position causes the transmitter to send the CAS
information stored in the XS(16:1) registers or serial CAS data
in the corresponding time slots.
Time slot 0 Transparent Mode
0=
Normal operation.
1=
All information for time slot 0 on port XDI is inserted in the
outgoing pulseframe. All internal information of the FALC56
(framing, CRC, Sa/Si-bit signaling, remote alarm) is ignored.
This function is mainly useful for system test applications (test
loops). Priority sequence of transparent modes: XSP.TTO >
TSWM.
E-Bit Polarity
0=
In the basic- and multiframe asynchronous state the E-bit is
cleared.
1=
In the basic- and multiframe asynchronous state the E-bit is set.
If automatic transmission of submultiframe status is enabled by
setting bit XSP.AXS and the receiver has lost synchronization,
the E-bit with the programmed polarity is inserted automatically
in Si-bit position of every outgoing CRC multiframe (under the
condition that time slot 0 transparent mode and transparent Si
bit in service word are both disabled).
Automatic Transmission of Submultiframe Status
Only applicable to CRC multiframe.
Data Sheet
0=
Normal operation.
1=
Information of submultiframe status bits RSP.SI1 and RSP.SI2
are inserted automatically in Si -bit positions of the outgoing
CRC multiframe (RSP.SI1 → Si -bit of frame 13; RSP.SI2 →
Si-bit of frame 15). Contents of XSP.XS13 and XSP.XS15 is
235
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
ignored. If one of the time slot 0 transparent modes XSP.TT0 or
TSWM.TSIS is enabled, bit XSP.AXS has no function.
XSIF
Transmit Spare Bit For International Use (FAS Word)
First bit in the FAS word. Only significant in doubleframe format. If not
used, this bit should be fixed to "1". If one of the time slot 0 transparent
modes is enabled (bits XSP.TT0, or TSWM.TSIF), bit XSP.XSIF is
ignored.
XS13
Transmit Spare Bit (Frame 13, CRC-Multiframe)
First bit in the service word of frame 13 for international use. Only
significant in CRC-multiframe format. If not used, this bit should be
fixed to "1". The information of XSP.XS13 is shifted into internal
transmission buffer with beginning of the next following transmitted
CRC multiframe.
If automatic transmission of submultiframe status is enabled by bit
XSP.AXS, or, if one of the time slot 0 transparent modes XSP.TT0 or
TSWM.TSIS is enabled, bit XSP.XS13 is ignored.
XS15
Transmit Spare Bit (Frame 15, CRC-Multiframe)
First bit in the service word of frame 15 for international use. Only
significant in CRC-multiframe format. If not used, this bit should be
fixed to "1". The information of XSP.XS15 is shifted into the internal
transmission buffer with beginning of the next following transmitted
CRC multiframe.
If automatic transmission of submultiframe status is enabled by bit
XSP.AXS, or, if one of the time slot 0 transparent modes XSP.TT0 or
TSWM.TSIF is enabled, bit XSP.XS15 is ignored.
Transmit Control 0 (Read/Write)
Value after reset: 00H
7
XC0
SA(8:4)E
Data Sheet
SA8E
0
SA7E
SA6E
SA5E
SA4E
XCO10
XCO9
XCO8
(22)
Sa-Bit Signaling Enable
0=
Standard operation.
1=
Setting this bit makes it possible to send/receive a LAPD
protocol in any combination of the Sa-bit positions in the
outgoing/incoming data stream. The on chip signaling controller
has to be configured in the HDLC/LAPD mode. In transmit
236
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
direction together with these bits the TSWM.TSA(8:4) bits must
be set to enable transmission to the remote end transparently
through the FALC56.
XCO(10:8)
Transmit Offset
Initial value loaded into the transmit bit counter at the trigger edge of
SCLKX when the synchronous pulse on port SYPX/XMFS is active
Refer to register XC1.
Transmit Control 1 (Read/Write)
Value after reset: 9CH
XC1
7
0
XCO7
XCO0
(23)
A write access to this address resets the transmit elastic buffer to its
basic starting position. Therefore, updating the value should only be
done when the FALC56 is initialized or when the buffer should be
centered. As a consequence a transmit slip will occur.
XCO(7:0)
Transmit Offset
Calculation of delay time T (SCLKX cycles) depends on the value X
of the “Transmit Offset” register XC(1:0):
0 ≤ T ≤ 4: X = 4 - T
5 ≤ T ≤ maximum delay: X = 256 × SC/SD - T + 4)
with maximum delay = (256 × SC/SD) -1
with SC = system clock defined by SIC1.SSC(1:0)
with SD = 2.048 MHz
Delay time T = time between beginning of time slot 0 (bit 0, channel
phase 0) at XDI/XSIG and the initial edge of SCLKX after SYPX/
XMFS goes active.
See page 111 for further description.
Data Sheet
237
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Control 0 (Read/Write)
Value after reset: 00H
7
RC0
SWD
ASY4
CRCI
SWD
0
ASY4
CRCI
XCRCI
RDIS
RCO10
RCO9
RCO8
(24)
Service Word Condition Disable
0=
Standard operation. Three or four consecutive incorrect service
words (depending on bit RC0.ASY4) causes loss of
synchronization.
1=
Errors in service words have no influence when in synchronous
state. However, they are used for the resynchronization
procedure.
Select Loss of Sync Condition
0=
Standard operation. Three consecutive incorrect FAS words or
three consecutive incorrect service words causes loss of
synchronization.
1=
Four consecutive incorrect FAS words or four consecutive
incorrect service words causes loss of synchronization. The
service word condition is disabled by bit RC0.SWD.
Automatic CRC4 Bit Inversion
If set, all CRC bits of one outgoing submultiframe are inverted in case
a CRC error is flagged for the previous received submultiframe. This
function is logically ored with RC0.XCRCI.
XCRCI
Transmit CRC4 Bit Inversion
If set, the CRC bits in the outgoing data stream are inverted before
transmission. This function is logically ored with RC0.CRCI.
RDIS
Receive Data Input Sense
Digital interface, dual-rail:
0=
Inputs RDIP/RDIN are active low
1=
Inputs RDIP/RDIN are active high
Digital Interface, CMI:
Data Sheet
0=
Input ROID is active high
1=
Input ROID is active low
238
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RCO(10:8)
Receive Offset/Receive Frame Marker Offset
Depending on the RP(A to D) pin function different offsets can be
programmed. The SYPR and the RFM pin function cannot be
selected in parallel.
Receive Offset (PC(4:1).RPC(2:0) = 000)
Initial value loaded into the receive bit counter at the trigger edge of
SCLKR when the synchronous pulse on port SYPR is active.
Calculation of delay time T (SCLKR cycles) depends on the value X
of the receive offset register RC(1:0). For programing refer to register
RC1.
Receive Frame Marker Offset (PC(4:1).RPC(2:0) = 001B)
Offset programming of the receive frame marker which is output on
port SYPR. The receive frame marker can be activated during any bit
position of the current frame.
Calculation of the value X of the receive offset register RC(1:0)
depends on the bit position which should be marked and SCLKR.
Refer to register RC1.
Receive Control 1 (Read/Write)
Value after reset: 9CH
RC1
RCO(7:0)
7
0
RCO7
RCO0
(25)
Receive Offset/Receive Frame Marker Offset
Depending on the RP(A to D) pin function different offsets can be
programmed. The SYPR and the RFM pin function cannot be
selected in parallel.
Receive Offset (PC(4:1).RPC(2:0) = 000)
Initial value loaded into the receive bit counter at the trigger edge of
SCLKR when the synchronous pulse on port SYPR is active.
Calculation of delay time T (SCLKR cycles) depends on the value X
of the receive offset register RC(1:0):
0 ≤ T ≤ 4: X = 4 - T
5 ≤ T ≤ maximum delay:X = 2052 - T
with maximum delay = (256×SC/SD) -1
with SC = system clock defined by SIC1.SSC(1:0)
with SD = system data rate
Data Sheet
239
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Delay time T = time between beginning of time slot 0 at RDO and the
initial edge of SCLKR after SYPR goes active.
See page 106 for further description.
Receive Frame Marker Offset (PC(4:1).RPC(2:0) = 001B)
Offset programming of the receive frame marker which is output on
multifunction port RFM. The receive frame marker can be activated
during any bit position of the entire frame and depends on the
selected system clock rate.
Calculation of the value X of the receive offset register RC(1:0)
depends on the bit position which should be marked at marker
position MP:
0 ≤ MP ≤ 2045:X = MP + 2
2046 ≤ MP ≤ 2047: X = MP - 2046
e.g: 2.048 MHz: MP = 0 to 255; up to 16.384 MHz: MP = 0 to 2047
Data Sheet
240
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit Pulse Mask (Read/Write)
Value after reset: 7BH, 03H, 40H
7
0
XPM0
XP12
XP11
XP10
XP04
XP03
XP02
XP01
XP00
(26)
XPM1
XP30
XP24
XP23
XP22
XP21
XP20
XP14
XP13
(27)
XPM2
0
XLT
DAXLT
XP34
XP33
XP32
XP31
(28)
The transmit pulse shape which is defined in ITU-T G.703 is output on pins XL1 and XL2.
The level of the pulse shape can be programmed by registers XPM(2:0) to create a
custom waveform. In order to get an optimized pulse shape for the external transformers
each pulse shape is internally divided into four sub pulse shapes. In each sub pulse
shape a programmed 5 bit value defines the level of the analog voltage on pins XL1/2.
Together four 5 bit values have to be programmed to form one complete transmit pulse
shape. The four 5 bit values are sent in the following sequence:
XP04 to 00:
XP14 to 10:
XP24 to 20:
XP34 to 30:
First pulse shape level
Second pulse shape level
Third pulse shape level
Fourth pulse shape level
Changing the LSB of each subpulse in registers XPM(2:0) changes the amplitude of the
differential voltage on XL1/2 by approximately 80 mV.
Example:120 Ω interface and wired as shown in Figure 50 on page 155.
XP04 to 00:
XP14 to 10:
XP24 to 20:
XP34 to 30:
1BH or 27 decimal
1BH or 27 decimal
00H
00H
Programming values for XPM(2:0): 00H, 03H,7BH
XLT
Data Sheet
Transmit Line Tristate
0=
Normal operation
1=
Transmit line XL1/XL2 or XDOP/XDON are switched into highimpedance state. If this bit is set the transmit line monitor status
information is frozen (default value after hardware reset).
241
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
DAXLT
Disable Automatic Tristating of XL1/2
0=
Normal operation. If a short is detected on pins XL1/2 the
transmit line monitor sets the XL1/2 outputs into a highimpedance state.
1=
If a short is detected on XL1/2 pins automatic setting these pins
into a high-impedance (by the XL-monitor) state is disabled.
Transparent Service Word Mask (Read/Write)
Value after reset: 00H
7
TSWM
TSIS
0
TSIF
TRA
TSA4
TSA5
TSA6
TSWM(7:0)
Transparent Service Word Mask
TSIS
Transparent Si-Bit in Service Word
TSIF
TRA
Data Sheet
TSA7
TSA8
(29)
0=
The Si-Bit is generated internally.
1=
The Si-Bit in the service word is taken from port XDI and
transparently passed through the FALC56 without any
changes. The internal information of the FALC56 (register
XSW) is ignored.
Transparent Si-Bit in FAS Word
0=
The Si-Bit is generated internally.
1=
The Si-Bit in the FAS word is taken from port XDI and routed
transparently through the FALC56 without any changes. The
internal information of the FALC56 (register XSW) is ignored.
Transparent Remote Alarm
0=
The remote alarm bit is generated internally.
1=
The A-Bit is taken from port XDI and routed transparently
through the FALC56 without any changes. The internal
information of the FALC56 (register XSW) is ignored.
242
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
TSA(8:4)
Transparent Sa(8:4)-Bit
0=
The Sa(8:4)-bits are generated internally.
1=
The Sa(8:4)-bits are taken from port XDI or from the internal
signaling controller if enabled and transparently passed
through the FALC56 without any changes. The internal
information of the FALC56 (registers XSW and XSA(8:4)) is
ignored.
Idle Channel Code Register (Read/Write)
Value after reset: 00H
IDLE
IDL(7:0)
7
0
IDL7
IDL0
(2B)
Idle Channel Code
If channel loop-back is enabled by programming LOOP.ECLB = 1,
the contents of the assigned outgoing channel on ports XL1/XL2 or
XDOP/XDON is set equal to the idle channel code selected by this
register.
Additionally, the specified pattern overwrites the contents of all
channels selected by the idle channel registers ICB(4:1). IDL7 is
transmitted first.
Data Sheet
243
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit Sa(8:4) Register (Read/Write)
Value after reset: 00H, 00H, 00H, 00H, 00H
7
0
XSA4
XS47
XS46
XS45
XS44
XS43
XS42
XS41
XS40
(2C)
XSA5
XS57
XS56
XS55
XS54
XS53
XS52
XS51
XS50
(2D)
XSA6
XS67
XS66
XS65
XS64
XS63
XS62
XS61
XS60
(2E)
XSA7
XS77
XS76
XS75
XS74
XS73
XS72
XS71
XS70
(2F)
XSA8
XS87
XS86
XS85
XS84
XS83
XS82
XS81
XS80
(30)
XSA(8:4)
Transmit Sa-Bit Data
The Sa-bit register access is enabled by setting bit FMR1.ENSA = 1.
With the transmit multiframe begin an interrupt ISR1.XMB is
generated and the contents of these registers XSA(8:4) is copied into
a shadow register. The contents is subsequently sent out in the
service words of the next outgoing CRC multiframe (or doubleframes)
if none of the time slot 0 transparent modes is enabled. XS40 is sent
out in bit position 4 in frame 1, XS47 in frame 15. The transmit
multiframe begin interrupt XMB request that these registers should be
serviced. If requests for new information are ignored, current contents
is repeated.
Data Sheet
244
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Framer Mode Register 3 (Read/Write)
Value after reset: 00H
7
0
FMR3
XLD
XLU
CMI
XLD
XLU
CMI
SA6SY
EXTIW
(31)
Transmit LLB Down Code
0=
Normal operation.
1=
A one in this bit position causes the transmitter to replace
normal transmit data with the LLB down (deactivate) Code
continuously until this bit is reset. The LLB down Code is
optionally overwritten by the time slot 0 depending on bit
LCR1.FLLB.
Transmit LLB UP Code
0=
Normal operation.
1=
A one in this bit position causes the transmitter to replace
normal transmit data with the LLB UP Code continuously until
this bit is reset. The LLB UP Code is overwritten by the time slot
0 depending on bit LCR1.FLLB. For proper operation bit
FMR3.XLD must be cleared.
Select CMI Precoding
Only valid if CMI code (FMR0.XC(1:0) = 01) is selected. This bit
defines the CMI precoding and influences transmit and receive data.
0=
CMI with HDB3 precoding
1=
CMI without HDB3 precoding
Note: Before local loop is selected, HDB3 precoding has to be
disabled.
SA6SY
Receive Sa6-Access Synchronous Mode
Only valid if multiframe format (FMR2.RFS(1:0) = 1x) is selected.
Data Sheet
0=
The detection of the predefined Sa6-bit pattern (refer to chapter
Sa6-bit detection according to ETS 300233) is done
independently of the multiframe synchronous state.
1=
The detection of the Sa6-bit pattern is done synchronously to
the multiframe.
245
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
EXTIW
Extended CRC4 to Non-CRC4 Interworking
Only valid in multiframe format. This bit selects the reaction of the
synchronizer after the 400 ms time-out has been elapsed and starts
transmitting a remote alarm if FMR2.AXRA is set.
0=
The CRC4 to Non CRC4 interworking is done as described in
ITU-T G. 706 Annex B.
1=
The interworking is done according to ITU-T G. 706 with the
exception that the synchronizer still searches the multiframing
even if the 400 ms timer is expired. Switching into doubleframe
format is disabled. If FMR2.AXRA is set the remote alarm bit is
active in the outgoing data stream until the multiframe is found.
Idle Channel Register (Read/Write)
Value after reset: 00H, 00H, 00H, 00H
7
0
ICB1
IC0
IC1
IC2
IC3
IC4
IC5
IC6
IC7
(32)
ICB2
IC8
IC9
IC10
IC11
IC12
IC13
IC14
IC15
(33)
ICB3
IC16
IC17
IC18
IC19
IC20
IC21
IC22
IC23
(34)
ICB4
IC24
IC25
IC26
IC27
IC28
IC29
IC30
IC31
(35)
IC(31:0)
Idle Channel Selection Bits
These bits define the channels (time slots) of the outgoing PCM frame
to be altered.
Assignments:
IC0 → Time slot 0
IC1 → Time slot 1
...
IC31 → Time slot 31
0=
Normal operation.
1=
Idle channel mode. The contents of the selected time slot is
overwritten by the idle channel code defined by register IDLE.
Note: Although time slot 0 can be selected by bit IC0, its contents is
only altered if the transparent mode is selected (XSP.TT0).
Data Sheet
246
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Line Interface Mode 0 (Read/Write)
Value after reset: 00H
7
LIM0
XFB
XFB
0
XDOS
EQON
RLM
LL
MAS
(36)
Transmit Full Bauded Mode
Only applicable for dual-rail mode (bit LIM1.DRS = 1).
0=
Output signals XDOP/XDON are half bauded.
1=
Output signals XDOP/XDON are full bauded.
Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to
be cleared.
XDOS
Transmit Data Out Sense
0=
Output signals XDOP/XDON are active low. Output XOID is
active high (normal operation).
1=
Output signals XDOP/XDON are active high. Output XOID is
active low.
Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to
be cleared.
The transmit frame marker XFM is independent of this bit.
EQON
RLM
LL
Data Sheet
Receive Equalizer On
0=
-10 dB receiver, short-haul mode
1=
-43 dB receiver, long-haul mode
Receive Line Monitoring
0=
Normal receiver mode
1=
Receiver mode for receive line monitoring;
the receiver sensitivity is increased to detect resistively
attenuated signals of -20 dB (short-haul mode only)
Local Loop
0=
Normal operation
1=
Local loop active. The local loop-back mode disconnects the
receive lines RL1/RL2 or RDIP/RDIN from the receiver. Instead
of the signals coming from the line the data provided by system
interface are routed through the analog receiver back to the
system interface. The unipolar bit stream is transmitted
247
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
undisturbedly on the line. Receiver and transmitter coding must
be identical. Operates in analog and digital line interface mode.
In analog line interface mode data is transferred through the
complete analog receiver.
MAS
Master Mode
0=
Slave mode
1=
Master mode on. Setting this bit the DCO-R circuitry is
frequency synchronized to the clock (2.048 MHz or 8 kHz, see
IPC.SSYF) supplied by SYNC. If this pin is connected to VSS or
VDD (or left open and pulled up to VDD internally) the DCO-R
circuitry is centered and no receive jitter attenuation is
performed (only if 2.048 MHz clock is selected by resetting bit
IPC.SSYF). The generated clocks are stable.
Line Interface Mode 1 (Read/Write)
Value after reset: 00H
7
LIM1
CLOS =
RIL(2:0)
CLOS
0
RIL2
RIL1
RIL0
JATT
RL
DRS
(37)
Clear data in case of LOS
0=
Normal receiver mode, receive data stream is transferred
normally in long-haul mode
1=
In long-haul mode received data is cleared (driven to low level),
as soon as LOS is detected
Receive Input Threshold
Only valid if analog line interface is selected (LIM1.DRS = 0).
“No signal” is declared if the voltage between pins RL1 and RL2 drops
below the limits programmed by bits RIL(2:0) and the received data
stream has no transition for a period defined in the PCD register.
The threshold where “no signal” is declared is programmable by the
RIL(2:0) bits depending on bit LIM0.EQON.
Note: LIM1.RIL(2:0) must be programmed before LIM0.EQON = 1 is
set.
See DC characteristics for detail.
Data Sheet
248
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
JATT, RL
Remote Loop Transmit Jitter Attenuator
00 = Normal operation. The remote loop transmit jitter attenuator is
disabled. Transmit data bypasses the remote loop jitter
attenuator buffer.
01 = Remote loop active without remote loop transmit jitter
attenuator enabled. Transmit data bypasses the remote loop
jitter attenuator buffer.
10 = not defined
11 = Remote loop and remote loop jitter attenuator active. Received
data from pins RL1/2 or RDIP/N or ROID is sent "jitter-free" on
ports XL1/2 or XDOP/N or XOID. The de-jittered clock is
generated by the DCO-X circuitry.
Note: JATT is only used to define the jitter attenuation during remote
loop operation. Jitter attenuation during normal operation is
not affected.
DRS
Dual-Rail Select
0=
The ternary interface is selected. Multifunction ports RL1/2 and
XL1/2 become analog in/outputs.
1=
The digital dual-rail interface is selected. Received data is
latched on multifunction ports RDIP/RDIN while transmit data is
output on pins XDOP/XDON.
Pulse Count Detection Register (Read/Write)
Value after reset: 00H
PCD
PCD(7:0)
7
0
PCD7
PCD0
(38)
Pulse Count Detection
A LOS alarm is detected if the incoming data stream has no
transitions for a programmable number T consecutive pulse
positions. The number T is programmable by the PCD register and
can be calculated as follows:
T = 16 × (N+1); with 0 ≤ N ≤ 255.
The maximum time is: 256 × 16 × 488 ns = 2 ms. Every detected
pulse resets the internal pulse counter. The counter is clocked with
the receive clock RCLK.
Data Sheet
249
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Pulse Count Recovery (Read/Write)
Value after reset: 00H
PCR
7
0
PCR7
PCR0
PCR(7:0)
(39)
Pulse Count Recovery
A LOS alarm is cleared if a pulse-density is detected in the received
bit stream. The number of pulses M which must occur in the
predefined PCD time interval is programmable by the PCR register
and can be calculated as follows:
M = N+1; with 0 ≤ N ≤ 255.
The time interval starts with the first detected pulse transition. With
every received pulse a counter is incremented and the actual counter
is compared to the contents of PCR register. If the pulse number is
higher or equal to the PCR value the LOS alarm is reset otherwise the
alarm stays active. In this case the next detected pulse transition
starts a new time interval.
Line Interface Mode 2 (Read/Write)
Value after reset: 20H
7
LIM2
SLT(1:0)
0
SLT1
SLT0
SCF
ELT
(3A)
Receive Slicer Threshold
00 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 55% of the peak amplitude.
01 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 67% of the peak amplitude (recommended in
some T1/J1 applications).
10 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 50% of the peak amplitude (default,
recommended in E1 mode).
11 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 45% of the peak amplitude.
Data Sheet
250
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
SCF
Select Corner Frequency of DCO-R
Setting this bit reduces the corner frequency of the DCO-R circuit by
the factor of ten to 0.2 Hz.
Note: Reducing the corner frequency of the DCO-R circuitry
increases the synchronization time before the frequencies are
synchronized.
ELT
Enable Loop-Timed
0=
Normal operation
1=
Transmit clock is generated from the clock supplied by MCLK
which is synchronized to the extracted receive route clock. In
this configuration the transmit elastic buffer has to be enabled.
Refer to register XSW.XTM. For correct operation of loop timed
the remote loop (bit LIM1.RL = 0) must be inactive and bit
CMR1.DXSS must be cleared.
Loop Code Register 1 (Read/Write)
Value after reset: 00H
7
LCR1
EPRM
XPRBS
EPRM
0
XPRBS
LDC1
LDC0
LAC1
LAC0
FLLB
LLBP
(3B)
Enable Pseudo-Random Binary Sequence Monitor
0=
Pseudo-Random Binary Sequence (PRBS) monitor is disabled.
1=
PRBS is enabled. Setting this bit enables incrementing the
CEC2 error counter with each detected PRBS bit error. With
any change of state of the PRBS internal synchronization
status an interrupt ISR1.LLBSC is generated. The current
status of the PRBS synchronizer is indicated by bit
RSP.LLBAD.
Transmit Pseudo-Random Binary Sequence
A one in this bit position enables transmission of a pseudo-random
binary sequence to the remote end. Depending on bit LLBP the PRBS
is generated according to 215-1 or 220-1 with a maximum-14-zero
restriction (ITU-T O. 151).
Data Sheet
251
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
LDC(1:0)
Length Deactivate (Down) Code
These bits defines the length of the LLB deactivate code which is
programmable in register LCR2.
00 = Length: 5 bit
01 = Length: 6 bit, 2 bit, 3 bit
10 = Length: 7 bit
11 = Length: 8 bit, 2 bit, 4bit
LAC(1:0)
Length Activate (Up) Code
These bits defines the length of the LLB activate code which is
programmable in register LCR3.
00 = Length: 5 bit
01 = Length: 6 bit, 2 bit, 3 bit
10 = Length: 7 bit
11 = Length: 8 bit, 2 bit, 4 bit
FLLB
Framed Line Loop-Back/Invert PRBS
Depending on bit LCR1.XPRBS this bit enables different functions:
LCR1.XPRBS = 0:
0=
The line loop-back code is transmitted including framing bits.
LLB code overwrites the FS/DL-bits.
1=
The line loop-back code is transmitted unframed. LLB code
does not overwrite the FS/DL-bits.
Invert PRBS
LCR1.XPRBS = 1:
LLBP
0=
The generated PRBS is transmitted not inverted.
1=
The PRBS is transmitted inverted.
Line Loop-Back Pattern
LCR1.XPRBS = 0
0=
Fixed line loop-back code according to ANSI T1. 403.
1=
Enable user-programmable line loop-back code by register
LCR2/3.
LCR1.XPRBS = 1 or LCR1.EPRM = 1
Data Sheet
0=
215 -1
1=
220 -1
252
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Loop Code Register 2 (Read/Write)
Value after reset: 00H
LCR2
7
0
LDC7
LDC0
LDC(7:0)
(3C)
Line Loop-Back Deactivate Code
If enabled by bit FMR3.XLD = 1 the LLB deactivate code
automatically repeats until the LLB generator is stopped. Transmit
data is overwritten by the LLB code. LDC0 is transmitted last. For
correct operations bit LCR1.XPRBS has to cleared.
If LCR2 is changed while the previous deactivate code has been
detected and is still received, bit RSP.LLBDD will stay active until the
incoming signal changes or a receiver reset is initiated
(CMDR.RRES = 1).
Loop Code Register 3 (Read/Write)
Value after reset: 00H
LCR3
LAC(7:0)
7
0
LAC7
LAC0
(3D)
Line Loop-Back Activate Code
If enabled by bit FMR3.XLU = 1 the LLB activate code automatically
repeats until the LLB generator is stopped. Transmit data is
overwritten by the LLB code. LAC0 is transmitted last. For correct
operations bit LCR1.XPRBS has to cleared.
If LCR3 is changed while the previous activate code has been
detected and is still received, bit RSP.LLBAD will stay active until the
incoming signal changes or a receiver reset is initiated
(CMDR.RRES = 1).
Data Sheet
253
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
System Interface Control 1 (Read/Write)
Value after reset: 00H
7
SIC1
SSC(1:0)
SSC1
0
SSD1
RBS1
RBS0
SSC0
BIM
XBS1
XBS0
(3E)
Select System Clock
SIC1.SSC(1:0) define the clocking rate on the system highway.
00 = 2.048 MHz
01 = 4.096 MHz
10 = 8.192 MHz
11 = 16.384 MHz
SSD1
Select System Data Rate 1
SIC1.SSD1 and FMR1.SSD0 define the data rate on the system
highway. Programming SSD1/SSD0 and corresponding data rate is
shown below.
00 = 2.048 Mbit/s
01 = 4.096 Mbit/s
10 = 8.192 Mbit/s
11 = 16.384 Mbit/s
RBS(1:0)
Receive Buffer Size
00 = Buffer size: 2 frames
01 = Buffer size: 1 frame
10 = Buffer size: 96 bits
11 = bypass of receive elastic store
BIM
XBS(1:0)
Bit Interleaved Mode
0=
Byte interleaved mode
1=
Bit interleaved mode
Transmit Buffer Size
00 = Bypass of transmit elastic store
01 = Buffer size: 1 frame
10 = Buffer size: 2 frames
11 = Buffer size: 96 bits
Data Sheet
254
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
System Interface Control 2 (Read/Write)
Value after reset: 00H
7
SIC2
FFS
FFS
0
SSF
CRB
SICS2
SICS1
SICS0
(3F)
Force Freeze Signaling
Setting this bit disables updating of the receive signaling buffer and
current signaling information is frozen. After resetting this bit and
receiving a complete superframe updating of the signaling buffer is
started again. The freeze signaling status can also be automatically
generated by detecting the loss-of-signal alarm or a loss of CAS
frame alignment or a receive slip (only if external register access on
pin RSIG is enabled). This automatic freeze signaling function is
logically ored with this bit.
The current internal freeze signaling status is output on pin RPA to
RPD using pin function FREEZE which is selected by
PC(4:1).RPC(2:0) = 110. Additionally, this status is also available in
register SIS.SFS.
SSF
Serial Signaling Format
Only applicable if pin function RSIG/XSIG and SIC3.TTRF = 0 is
selected.
CRB
0=
Bits 1 to 4 in all time slots except time slots 0 and16 are cleared.
1=
Bits 1 to 4 in all time slots except time slots 0 and16 are set
high.
Center Receive Elastic Buffer
Only applicable if the time slot assigner is disabled
(PC(4:1).RPC(2:0) = 001B), no external or internal synchronous pulse
receive is generated.
A transition from low to high forces a receive slip and the read- pointer
of the receive elastic buffer is centered. The delay through the buffer
is set to one half of the current buffer size. It should be hold high for
at least two 2.048 MHz periods before it is cleared.
SICS(2:0)
System Interface Channel Select
Only applicable if the system clock rate is greater than 2.048 MHz.
Received data is transmitted on pin RDO/RSIG or received on XDI/
XSIG with the selected system data rate. If the data rate is greater
than 2.048 Mbit/s the data is output or sampled in half, a quarter or
Data Sheet
255
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
one eighth of the time slot. Data is not repeated. The time while data
is active during a 8 × 488 ns time slot is called a channel phase. RDO/
RSIG are cleared (driven to low level) while XDI/XSIG are ignored for
the remaining time of the 8 × 488 ns or for the remaining channel
phases. The channel phases are selectable with these bits.
000 = Data active in channel phase 1, valid if system data rate is
16⁄8⁄4 Mbit/s
001 = Data active in channel phase 2, valid if system data rate is
16⁄8⁄4 Mbit/s
010 =Data active in channel phase 3, valid if data rate is 16/8 Mbit/s
011 = Data active in channel phase 4, valid if data rate is 16/8 Mbit/s
100 = Data active in channel phase 5, valid if data rate is 16 Mbit/s
101 = Data active in channel phase 6, valid if data rate is 16 Mbit/s
110 = Data active in channel phase 7, valid if data rate is 16 Mbit/s
111 = Data active in channel phase 8, valid if data rate is 16 Mbit/s
System Interface Control 3 (Read/Write)
Value after reset: 00H
7
SIC3
0
CASMF
CASMF
Data Sheet
RESX
RESR
TTRF
DAF
(40)
CAS Multiframe Begin Marker
0=
The time slot 0 multiframe begin is asserted on pin RP(A to D)/
pin function RMFB.
1=
The time slot 16 CAS multiframe begin is asserted on pin RP(A
to D)/pin function RMFB.
256
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RESX
Rising Edge Synchronous Pulse Transmit
Depending on this bit all transmit system interface data and marker
are clocked or sampled with the selected active edge.
CMR2.IXSC = 0:
0
latched with the first falling edge of the selected PCM highway
clock.
1
latched with the first rising edge of the selected PCM highway
clock.
CMR2.IXSC = 1:
value of RESX bit has no impact on the selected edge of the PCM
highway clock but value of RESR bit is used as RESX.
Example: If RESR = 0, the rising edge of PCM highway clock is the
selected one for sampling data on XDI and vice versa.
RESR
Rising Edge Synchronous Pulse Receive
Depending on this bit all receive system interface data and marker are
clocked with the selected active edge.
0=
Latched with the first falling edge of the selected PCM highway
clock.
1=
Latched with the first rising edge of the selected PCM highway
clock.
Note: If bit CMR2.IRSP is set, the behavior of signal RFM (if used) is
inverse (1 = falling edge, 0 = rising edge)
TTRF
TTR Register Function (Fractional E1 Access)
Setting this bit the function of the TTR(4:1) registers is changed. A
one in each TTR register forces the XSIGM marker high for the
corresponding time slot and controls sampling of the time slots
provided on pin XSIG. XSIG is selected by PC(4:1).XPC(3:0).
DAF
Data Sheet
Disable Automatic Freeze
0=
Signaling is automatically frozen if one of the following alarms
occurred: Loss-Of-Signal (FRS0.LOS), Loss of CAS Frame
Alignment (FRS1.TS16LFA), or receive slips (ISR3.RSP/N).
1=
Automatic freezing of signaling data is disabled. Updating of the
signaling buffer is also done if one of the above described alarm
conditions is active. However, updating of the signaling buffer
is stopped if SIC2.FFS is set. Significant only if the serial
signaling access is enabled.
257
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Clock Mode Register 1 (Read/Write)
Value after reset: 00H
7
0
CMR1
RS(1:0)
RS1
RS0
DCS
STF
DXJA
DXSS
(44)
Select RCLK Source
These bits select the source of RCLK.
00 = Clock recovered from the line through the DPLL drives RCLK
01 = Clock recovered from the line through the DPLL drives RCLK
and in case of an active LOS alarm RCLK pin is set high.
10 = Clock recovered from the line is de-jittered by DCO-R to drive a
2.048 MHz clock on RCLK.
11 = Clock recovered from the line is de-jittered by DCO-R to drive a
8.192 MHz clock on RCLK.
DCS
Disable Clock-Switching
In Slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the
recovered route clock. In case of loss-of-signal LOS the DCO-R
switches automatically to the clock sourced by port SYNC. Setting
this bit automatic switching from RCLK to SYNC is disabled.
STF
Select TCLK Frequency
Only applicable if the pin function TCLK port XP(A to D) is selected by
PC(4:1).XPC(3:0) = 0011B. Data on XL1/2 (XDOP/N / XOID) are
clocked with TCLK.
DXJA
0=
2.048 MHz
1=
8.192 MHz
Disable Internal Transmit Jitter Attenuation
Setting this bit disables the transmit jitter attenuation. Reading the
data out of the transmit elastic buffer and transmitting on XL1/2
(XDOP/N/XOID) is done with the clock provided on pin TCLK. In
transmit elastic buffer bypass mode the transmit clock is taken from
SCLKX, independent of this bit.
Data Sheet
258
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
DXSS
DCO-X Synchronization Clock Source
0=
The DCO-X circuitry synchronizes to the internal reference
clock which is sourced by SCLKX/R or RCLK. Since there are
many reference clock opportunities the following internal
prioritizing in descending order from left to right is realized:
LIM1.RL > CMR1.DXSS > LIM2.ELT > current working clock of
transmit system interface.
If one of these bits is set the corresponding reference clock is
taken.
1=
DCO-X synchronizes to an external reference clock provided
on pin XP(A to D) pin function TCLK, if no remote loop is active.
TCLK is selected by PC(4:1).XPC(3:0) = 0011B.
Clock Mode Register 2 (Read/Write)
Value after reset: 00H
7
0
CMR2
DCOXC
DCF
Data Sheet
DCOXC
DCF
IRSP
IRSC
IXSP
IXSC
(45)
DCO-X Center-Frequency Enable
0=
The center function of the DCO-X circuitry is disabled.
1=
The center function of the DCO-X circuitry is enabled.
DCO-X centers to 2.048 MHz related to the master clock
reference (MCLK), if reference clock (e.g. SCLKX) is missing.
DCO-R Center- Frequency Disabled
0=
The DCO-R circuitry is frequency centered
- in master mode if no 2.048 MHz reference clock on pin SYNC
is provided or
- in slave mode if a loss-of-signal occurs in combination with no
2.048 MHz clock on pin SYNC or
- a gapped clock is provided on pin RCLKI and this clock is
inactive or stopped.
1=
The center function of the DCO-R circuitry is disabled. The
generated clock (DCO-R) is frequency frozen in that moment
when no clock is available on pin SYNC or pin RCLKI. The
DCO-R circuitry starts synchronization as soon as a clock
appears on pins SYNC or RCLKI.
259
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
IRSP
Internal Receive System Frame Sync Pulse
0=
The frame sync pulse for the receive system interface is
sourced by SYPR (if SYPR is applied). If SYPR is not applied,
the frame sync pulse is derived from RDO output signal
internally free running).
The use of IRSP = 0 is recommended.
1=
The frame sync pulse for the receive system interface is
internally sourced by the DCO-R circuitry. This internally
generated frame sync signal can be output (active low) on
multifunction ports RP(A to D) (RPC(2:0) = 001B).
Note: This is the only exception where the use of RFM and
SYPR is allowed at the same time. Because only one set of
offset registers (RC1/0) is available, programming is done by
using the SYPR calculation formula in the same way as for the
external SYPR pulse. Bit IRSC must be set for correct
operation.
IRSC
IXSP
IXSC
Data Sheet
Internal Receive System Clock
0=
The working clock for the receive system interface is sourced
by SCLKR or in receive elastic buffer bypass mode from the
corresponding extracted receive clock RCLK.
1=
The working clock for the receive system interface is sourced
internally by DCO-R or in bypass mode by the extracted receive
clock. SCLKR is ignored.
Internal Transmit System Frame Sync Pulse
0=
The frame sync pulse for the transmit system interface is
sourced by SYPX.
1=
The frame sync pulse for the transmit system interface is
internally sourced by the DCO-R circuitry. Additionally, the
external XMFS signal defines the transmit multiframe begin.
XMFS is enabled or disabled by the multifunction port
configuration. For correct operation bits CMR2.IXSC/IRSC
must be set. SYPX is ignored.
Internal Transmit System Clock
0=
The working clock for the transmit system interface is sourced
by SCLKX.
1=
The working clock for the transmit system interface is sourced
internally by the working clock of the receive system interface.
SCLKX is ignored.
260
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Global Configuration Register (Read/Write)
Value after reset: 00H
7
GCR
VIS
SCI
SES
ECMC
PD
VIS
0
SCI
SES
ECMC
PD
(46)
Masked Interrupts Visible
0=
Masked interrupt status bits are not visible in registers ISR(5:0).
1=
Masked interrupt status bits are visible in ISR(5:0), but they are
not visible in register GIS.
Status Change Interrupt
0=
Interrupts are generated either on activation or deactivation of
the internal interrupt source.
1=
The following interrupts are activated both on activation and
deactivation of the internal interrupt source:
ISR2.LOS, ISR2.AIS, ISR3.LMFA16
Select External Second Timer
0=
Internal second timer selected
1=
External second timer selected
Error Counter Mode COFA
0=
The Sa6-bit error indications are accumulated in the error
counter CEC3L/H.
1=
A Change of Frame or Multiframe Alignment COFA is detected
since the last resynchronization. The events are accumulated
in the error counter CEC3L.(1:0).
Multiframe periods received in the asynchronous state are
accumulated in the error counter CEC3L.7-2.
An overflow of each counter is disabled.
Power Down
Switches between power-up and power-down mode.
Data Sheet
0=
Power up
1=
Power down
All outputs are driven inactive; multifunction ports are driven
high by the weak internal pullup device.
261
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Errored Second Mask (Read/Write)
Value after reset: FFH
7
ESM
LFA
ESM
0
FER
CER
AIS
LOS
CVE
SLIP
EBE
(47)
Errored Second Mask
This register functions as an additional mask register for the interrupt
status bit Errored Second (ISR3.ES). A "1" in a bit position of ESM
deactivates the related second interrupt.
Disable Error Counter (Write)
Value after reset: 00H
7
DEC
DRBD
DRBD
0
DCEC3
DCEC2
DCEC1
DEBC
DCVC
DFEC
(60)
Disable Receive Buffer Delay
This bit has to be set before reading the register RBD. It is reset
automatically if RBD has been read.
DCEC3
Disable CRC Error Counter 3
DCEC2
Disable CRC Error Counter 2
DCEC1
Disable CRC Error Counter
DEBC
Disable Errored Block Counter
DCVC
Disable Code Violation Counter
DFEC
Disable Framing Error Counter
These bits are only valid if FMR1.ECM is cleared. They have to be set
before reading the error counters. They are reset automatically if the
corresponding error counter high byte has been read. With the rising
edge of these bits the error counters are latched and then cleared.
Note: Error counters and receive buffer delay can be read 1 µs after setting the
according bit in bit DEC.
Data Sheet
262
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit CAS Register (Write)
Value after reset: not defined
Table 59
Transmit CAS Registers (E1)
7
0
XS1
0
0
0
0
X
Y
X
X
(70)
XS2
A1
B1
C1
D1
A16
B16
C16
D16
(71)
XS3
A2
B2
C2
D2
A17
B17
C17
D17
(72)
XS4
A3
B3
C3
D3
A18
B18
C18
D18
(73)
XS5
A4
B4
C4
D4
A19
B19
C19
D19
(74)
XS6
A5
B5
C5
D5
A20
B20
C20
D20
(75)
XS7
A6
B6
C6
D6
A21
B21
C21
D21
(76)
XS8
A7
B7
C7
D7
A22
B22
C22
D22
(77)
XS9
A8
B8
C8
D8
A23
B23
C23
D23
(78)
XS10
A9
B9
C9
D9
A24
B24
C24
D24
(79)
XS11
A10
B10
C10
D10
A25
B25
C25
D25
(7A)
XS12
A11
B11
C11
D11
A26
B26
C26
D26
(7B)
XS13
A12
B12
C12
D12
A27
B27
C27
D27
(7C)
XS14
A13
B13
C13
D13
A28
B28
C28
D28
(7D)
XS15
A14
B14
C14
D14
A29
B29
C29
D29
(7E)
XS16
A15
B15
C15
D15
A30
B30
C30
D30
(7F)
Transmit CAS Register (16:1)
The transmit CAS register access is enabled by setting bit XSP.CASEN = 1. Each
register except XS1 contains the CAS bits for two time slots. With the transmit multiframe
begin ISR1.XMB the contents of these registers is copied into a shadow register. The
contents is sent out subsequently in the time slots 16 of the outgoing data stream.
Note:
If ISR1.XMB is not used and the write access to these registers is done exact in
the moment when this interrupt is generated, data is lost.
XS1.7 is sent out first and XS16.0 is sent last. The transmit multiframe begin interrupt
(XMB) requests that these registers should be serviced. If requests for new information
are ignored, current contents is repeated. XS1 has to be programmed with the
multiframe pattern. This pattern should always stay low otherwise the remote end loses
its synchronization. With setting the Y-bit a remote alarm is transmitted to the far end.
The X bits (spare bits) should be set if they are not used.
Data Sheet
263
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
If access to these registers is done without control of the interrupt ISR1.XMB the
registers should be written twice to avoid an internal data transfer error.
Note: A software reset (CMDR.XRES) resets these registers.
Port Configuration 1 to 4 (Read/Write)
Value after reset: 00H
7
0
PC1
RPC12
RPC11
RPC10
XPC13
XPC12
XPC11
XPC10
(80)
PC2
RPC22
RPC21
RPC20
XPC23
XPC22
XPC21
XPC20
(81)
PC3
RPC32
RPC31
RPC30
XPC33
XPC32
XPC31
XPC30
(82)
PC4
RPC42
RPC41
RPC40
XPC43
XPC42
XPC41
XPC40
(83)
RPC(2:0)
Receive multifunction port configuration
The multifunction ports RP(A to D) are bidirectional. After Reset these
ports are configured as inputs. With the selection of the pin function
the In/Output configuration is also achieved. The input function SYPR
may only be selected once, it must not be selected twice or more.
Register PC1 configures port RPA, while PC2 → port RPB,
PC3 → port RPC and PC4 → port RPD.
000 = SYPR: Synchronous Pulse Receive (Input)
Together with register RC(1:0) SYPR defines the frame begin
on the receive system interface. Because of the offset
programming the SYPR and the RFM pin function cannot be
selected in parallel.
001 = RFM: Receive Frame Marker (Output)
CMR2.IRSP = 0:
The receive frame marker is active high for one 2.048 MHz
period during any bit position of the current frame.
Programming of the bit position is done by using registers
RC(1:0). The internal time slot assigner is disabled. The RFM
offset calculation formula has to be used.
CMR2.IRSP = 1:
Internally generated frame synchronization pulse sourced by
the DCO-R circuitry. The pulse is active low for one 2.048 MHz
period.
Data Sheet
264
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
010 =RMFB: Receive Multiframe Begin (Output)
Marks the beginning of every received multiframe or optionally
the begin of every CAS multiframe begin (active high).
011 = RSIGM: Receive Signaling Marker (Output)
Marks the time slots which are defined by register RTR(4:1) of
every frame on port RDO.
100 = RSIG: Receive Signaling Data (Output)
The received CAS multiframe is transmitted on this pin. Time
slot on RSIG correlates directly to the time slot assignment on
RDO.
101 = DLR: Data Link Bit Receive (Output)
Marks the Sa-bits within the data stream on RDO.
110 = FREEZE: Freeze Signaling (Output)
The freeze signaling status is active high by detecting a loss-ofsignal alarm, or a loss of CAS frame alignment or a receive slip
(positive or negative). It stays high for at least one complete
multiframe after the alarm disappears. Setting SIC2.FFS
enforces a high on pin FREEZE.
111 = RFSP: Receive Frame Synchronous Pulse (Output)
Marks the frame begin in the receivers synchronous state. This
marker is active low for 488 ns with a frequency of 8 kHz.
XPC(3:0)
Transmit multifunction Port Configuration
The multifunction ports XP(A to D) are bidirectional. After Reset these
ports are configured as inputs. With the selection of the pin function
the In/Output configuration is also achieved. Each of the four different
input functions (SYPX, XMFS, XSIG, TCLK) may only be selected
once. No input function must be selected twice or more. SYPX and
XMFS should not be selected in parallel. Register PC1 configures
port XPA, while PC2 → port XPB, PC3 → port XPC and PC4 → port
XPD.
0000 = SYPX: Synchronous Pulse Transmit (Input)
Together with register XC(1:0) SYPX defines the frame begin
on the transmit system interface ports XDI and XSIG.
0001 = XMFS: Transmit Multiframe Synchronization (Input)
Together with register XC(1:0) XMFS defines the frame and
multiframe begin on the transmit system interface ports XDI
and XSIG. Depending on PC5.CXMFS the signal on XMFS is
active high or low.
0010 = XSIG: Transmit Signaling Data (Input)
Input for transmit signaling data received from the signaling
Data Sheet
265
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
highway. Optionally sampling of XSIG data is controlled by
the active high XSIGM marker.
0011 = TCLK: Transmit Clock (Input)
A 2.048/8.192 MHz clock has to be sourced by the system if
the internal generated transmit clock (DCO-X) is not used.
Optionally this input is used as a synchronization clock for the
DCO-X circuitry with a frequency of 2.048 MHz.
0100 = XMFB: Transmit Multiframe Begin (Output)
Marks the beginning of every transmit multiframe.
0101 = XSIGM: Transmit Signaling Marker (Output)
Marks the time slots which are defined by register TTR(4:1) of
every frame on port XDI.
0110 = DLX: Data Link Bit Transmit (Output)
Marks the Sa-bits within the data stream on XDI.
0111 = XCLK: Transmit Line Clock (Output)
Frequency: 2.048 MHz
1000 = XLT: Transmit Line Tristate (Input)
With a high level on this port the transmit lines XL1/2 or
XDOP/N are set directly into tristate. This pin function is
logically ored with register XPM2.XLT.
Port Configuration 5 (Read/Write)
Value after reset: 00H
7
0
PC5
CCLK2
CCLK1
Data Sheet
CCLK2
CCLK1
CXMFS
0
CSRP
CRP
(84)
Configure CLK2 Port
0=
CLK2 is input
1=
CLK2 is output (only, if DCO-X is active)
Configure CLK1 Port
0=
CLK1 is input
1=
CLK1 is output (only, if DCO-R is active)
266
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
CXMFS
Configure XMFS Port
PC5(2)
0=
Port XMFS is active low.
1=
Port XMFS is active high.
reserved.
Must be cleared
CSRP
Configure SCLKR Port
CRP
0=
SCLKR: Input
1=
SCLKR: Output
Configure RCLK Port
0=
RCLK: Input
1=
RCLK: Output
Global Port Configuration 1 (Read/Write)
Value after reset: 00H
7
0
GPC1
CSFP1
CSFP0
(85)
CSFP(1:0)
Configure SEC/FSC Port
The FSC pulse is generated if the DCO-R circuitry of the selected
channel is active (CMR2.IRSC = 1 or CMR1.RS(1:0) = 10 or 11).
00 = SEC: Input, active high
01 = SEC: Output, active high
10 = FSC: Output, active high
11 = FSC: Output, active low
Data Sheet
267
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Port Configuration 6 (Read/Write)
Value after reset: 00H
7
0
PC6
SXCL(1:0)
SXCL1
SXCL0
SCL2
SCL1
SCL0
(86)
Select Transmit Clock Frequency on Port CLK2
Port CLK2 is the de-jittered DCO-X clock at a frequency of
00 = 2.048 MHz
01 = 4.096 MHz
10 = 8.192 MHz
11 = 16.384 MHz
Note: If DCO-X is not used, no clock is output on pin CLK2
(SIC1.XBS(1:0)=00 and CMR1.DXJA=1; buffer bypass and
no jitter attenuation)
SCL(2:0)
Select System Clock Frequency on Port CLK1
Port CLK1 is the de-jittered DCO-R clock at a frequency of
000 = 8 kHz
001 = 2.048 MHz
010 = 4.096 MHz
011 = 8.192 MHz
100 = 16.384 MHz
101 to 111 = Not defined
Note: If DCO-R is not active, no clock is output on pin CLK1
(SIC1.RBS(1:0)=11 and CMR1.RS1=0).
Data Sheet
268
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Command Register 2 (Write)
Value after reset: 00H
CMDR2
RSUC
RSUC
(x87)
Reset Signaling Unit Counter
After setting this bit the SS7 signaling unit counter and error counter
are reset.The bit is cleared automatically after execution.
Note: The maximum time between writing to the CMDR2 register
and the execution of the command takes 2.5 periods of the
current system data rate. Therefore, if the CPU operates with
a very high clock rate in comparison with the FALC56's clock,
it is recommended that bit SIS.CEC should be checked before
writing to the CMDR2 register to avoid any loss of commands.
Command Register 3 (Write)
Value after reset: 00H
7
CMDR3
RMC2
RMC2
0
XREP2
XHF2
XTF2
XME2
SRES2
(88)
Receive Message Complete - HDLC Channel 2
Confirmation from CPU to FALC® that the current frame or data block
has been fetched following an RPF2 or RME2 interrupt, thus the
occupied space in the RFIFO2 can be released.
XREP2
Transmission Repeat - HDLC Channel 2
If XREP2 is set together with XTF2 (write 24H to CMDR3), the FALC®
repeatedly transmits the contents of the XFIFO2 (1 to 32 bytes)
without HDLC framing fully transparently, i.e. without flag, CRC.
The cyclic transmission is stopped with an SRES2 command or by
resetting XREP2.
XHF2
Transmit HDLC Frame - HDLC Channel 2
After having written up to 32 bytes to the XFIFO2, this command
initiates the transmission of a HDLC frame.
Data Sheet
269
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XTF2
Transmit Transparent Frame - HDLC Channel 2
Initiates the transmission of a transparent frame without HDLC
framing.
XME2
Transmit Message End - HDLC Channel 2
Indicates that the data block written last to the XFIFO2 completes the
current frame. The FALC® can terminate the transmission operation
properly by appending the CRC and the closing flag sequence to the
data.
SRES2
Signaling Transmitter Reset - HDLC Channel 2
The transmitter of the signaling controller is reset. XFIFO2 is cleared
of any data and an abort sequence (seven 1s) followed by interframe
time fill is transmitted. In response to SRES2 an XPR2 interrupt is
generated.
This command can be used by the CPU to abort a frame currently in
transmission.
Command Register 4 (Write)
Value after reset: 00H
7
CMDR4
RMC3
RMC3
0
XREP3
XHF3
XTF3
XME3
SRES3
(89)
Receive Message Complete - HDLC Channel 3
Confirmation from CPU to FALC® that the current frame or data block
has been fetched following an RPF3 or RME3 interrupt, thus the
occupied space in the RFIFO3 can be released.
XREP3
Transmission Repeat - HDLC Channel 3
If XREP3 is set together with XTF3 (write 24H to CMDR4), the FALC®
repeatedly transmits the contents of the XFIFO3 (1 to 32 bytes)
without HDLC framing fully transparently, i.e. without flag, CRC.
The cyclic transmission is stopped with an SRES3 command or by
resetting XREP3.
XHF3
Transmit HDLC Frame - HDLC Channel 3
After having written up to 32 bytes to the XFIFO3, this command
initiates the transmission of a HDLC frame.
Data Sheet
270
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XTF3
Transmit Transparent Frame - HDLC Channel 3
Initiates the transmission of a transparent frame without HDLC
framing.
XME3
Transmit Message End - HDLC Channel 3
Indicates that the data block written last to the XFIFO3 completes the
current frame. The FALC® can terminate the transmission operation
properly by appending the CRC and the closing flag sequence to the
data.
SRES3
Signaling Transmitter Reset - HDLC Channel 3
The transmitter of the signaling controller is reset. XFIFO3 is cleared
of any data and an abort sequence (seven 1s) followed by interframe
time fill is transmitted. In response to SRES3 an XPR3 interrupt is
generated.
This command can be used by the CPU to abort a frame currently in
transmission.
Common Configuration Register 3 (Read/Write)
Value after reset: 00H
7
0
CCR3
RADD2
RCRC2
XCRC2
ITF2
XMFA2
RADD2
Receive Address Pushed to RFIFO2
RFT12
RFT02
(8B)
If this bit is set, the received HDLC channel 2 address information (1
or 2 bytes, depending on the address mode selected via
MODE2.MDS02) is pushed to RFIFO2. This function is applicable in
non-auto mode and transparent mode 1.
RCRC2
Receive CRC ON/OFF - HDLC Channel 2
Only applicable in non-auto mode.
If this bit is set, the received CRC checksum is written to RFIFO2
(CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in
the received frame, is followed in the RFIFO2 by the status
information byte (contents of register RSIS2). The received CRC
checksum will additionally be checked for correctness. If non-auto
mode is selected, the limits for “Valid Frame” check are modified.
Data Sheet
271
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XCRC2
Transmit CRC ON/OFF - HDLC Channel 2
If this bit is set, the CRC checksum will not be generated internally. It
has to be written as the last two bytes in the transmit FIFO (XFIFO2).
The transmitted frame is closed automatically with a closing flag.
ITF2
Interframe Time Fill - HDLC Channel 2
Determines the idle (= no data to be sent) state of the transmit data
coming from the signaling controller.
XMFA2
0=
Continuous logical "1" is output
1=
Continuous flag sequences are output ("01111110" bit patterns)
Transmit Multiframe Aligned - HDLC Channel 2
Determines the synchronization between the framer and the
corresponding signaling controller.
RFT12, RFT02
0=
The contents of the XFIFO2 is transmitted without multiframe
alignment.
1=
The contents of the XFIFO2 is transmitted multiframe aligned.
RFIFO2 Threshold Level - HDLC Channel 2
The size of the accessible part of RFIFO2 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT12
RFT02
Size of Accessible Part of RFIFO2
0
0
1
1
0
1
0
1
32 bytes (default value)
16 bytes
4 bytes
2 bytes
The value of RFT(1:0)2 can be changed dynamically if reception is
not running or after the current data block has been read, but before
the command CMDR3.RMC2 is issued (interrupt controlled data
transfer).
Data Sheet
272
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Common Configuration Register 4 (Read/Write)
Value after reset: 00H
7
0
CCR4
RADD3
RCRC3
XCRC3
ITF3
XMFA3
RADD3
Receive Address Pushed to RFIFO3
RFT13
RFT03
(8C)
If this bit is set, the received HDLC channel 3 address information (1
or 2 bytes, depending on the address mode selected via
MODE3.MDS03) is pushed to RFIFO3. This function is applicable in
non-auto mode and transparent mode 1.
RCRC3
Receive CRC ON/OFF - HDLC Channel 3
Only applicable in non-auto mode.
If this bit is set, the received CRC checksum is written to RFIFO3
(CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in
the received frame, is followed in the RFIFO3 by the status
information byte (contents of register RSIS3). The received CRC
checksum will additionally be checked for correctness. If non-auto
mode is selected, the limits for “Valid Frame” check are modified.
XCRC3
Transmit CRC ON/OFF - HDLC Channel 3
If this bit is set, the CRC checksum will not be generated internally. It
has to be written as the last two bytes in the transmit FIFO (XFIFO3).
The transmitted frame is closed automatically with a closing flag.
ITF3
Interframe Time Fill - HDLC Channel 3
Determines the idle (= no data to be sent) state of the transmit data
coming from the signaling controller.
XMFA3
0=
Continuous logical "1" is output
1=
Continuous flag sequences are output ("01111110" bit patterns)
Transmit Multiframe Aligned - HDLC Channel 3
Determines the synchronization between the framer and the
corresponding signaling controller.
Data Sheet
0=
The contents of the XFIFO3 is transmitted without multiframe
alignment.
1=
The contents of the XFIFO3 is transmitted multiframe aligned.
273
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RFT13, RFT03
RFIFO3 Threshold Level - HDLC Channel 3
The size of the accessible part of RFIFO3 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT13
RFT03
Size of Accessible Part of RFIFO3
0
0
1
1
0
1
0
1
32 bytes (default value)
16 bytes
4 bytes
2 bytes
The value of RFT13/03 can be changed dynamically if reception is not
running or after the current data block has been read, but before the
command CMDR4.RMC3 is issued (interrupt controlled data
transfer).
Common Configuration Register 5 (Read/Write)
Value after reset: 00H
7
0
CCR5
SUET
CSF
AFX
(x8D)
Note: These bits are only valid, if SS7 mode of HDLC channel 1 is
selected.
SUET
CSF
AFX
Data Sheet
Signaling Unit Error Threshold
Defines the number of signaling units received in error that will cause
an error rate high indication (ISR1.SUEX).
0=
Threshold 64 errored signaling units
1=
Threshold 32 errored signaling units
Compare Status Field
If the status fields of consecutive LSSUs are equal, only the first is
stored and every following is ignored.
0=
Compare disabled.
1=
Compare enabled.
Automatic FISU Transmission
After the contents of the transmit FIFO (XFIFO) has been transmitted
completely, FISUs are transmitted automatically. These FISUs
contain the FSN and BSO of the last transmitted signaling unit.
274
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
0=
Automatic FISU transmission disabled.
1=
Automatic FISU transmission enabled.
Mode Register 2 (Read/Write)
Value after reset: 00H
7
MODE2
MDS22
MDS2(2:0)
0
MDS21
MDS20
HRAC2
DIV2
(8E)
Mode Select - HDLC Channel 2
The operating mode of the HDLC controller is selected.
000 = Reserved
001 = Reserved
010 = One-byte address comparison mode (RAL1, 2)
011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2)
100 = No address comparison
101 = One-byte address comparison mode (RAH1, 2)
110 = Reserved
111 = No HDLC framing mode 1
HRAC2
Receiver Active - HDLC Channel 2
Switches the HDLC receiver to operational or inoperational state.
DIV2
0=
Receiver inactive
1=
Receiver active
Data Inversion - HDLC Channel 2
Setting this bit will invert the internal generated HDLC data stream.
Data Sheet
0=
Normal operation, HDLC data stream not inverted
1=
HDLC data stream inverted
275
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Mode Register 3 (Read/Write)
Value after reset: 00H
7
MODE3
MDS32
MDS3(2:0)
0
MDS31
MDS30
HRAC3
DIV3
(8F)
Mode Select - HDLC Channel 3
The operating mode of the HDLC controller is selected.
000 = Reserved
001 = Reserved
010 = One-byte address comparison mode (RAL1, 2)
011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2)
100 = No address comparison
101 = One-byte address comparison mode (RAH1, 2)
110 = Reserved
111 = No HDLC framing mode 1
HRAC3
Receiver Active - HDLC Channel 3
Switches the HDLC receiver to operational or inoperational state.
DIV3
0=
Receiver inactive
1=
Receiver active
Data Inversion - HDLC Channel 3
Setting this bit will invert the internal generated HDLC data stream.
Data Sheet
0=
Normal operation, HDLC data stream not inverted
1=
HDLC data stream inverted
276
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Global Clock Mode Register 1 (Read/Write)
Value after reset: 00H
7
GCM1
0
PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1
7
6
5
4
3
2
1
0
PHD_E1(7:0)
(92)
Frequency Adjust for E1
For details see calculation formulas below.
Global Clock Mode Register 2 (Read/Write)
Value after reset: 00H
7
GCM2
0
DVM_E1 DVM_E1 DVM_E1 VFREQ_ PHD_E1 PHD_E1 PHD_E1 PHD_E1
2
1
0
EN
11
10
9
8
PHD_E1(8:11)
(93)
Frequency Adjust for E1
For details see calculation formulas below.
VFREQ_EN
DVM_E1(0:2)
Variable Frequency Enable
0=
Fixed clock frequency of 2.048 (E1) or 1.544 MHz (T1/J1)
1=
Variable master clock frequency
Divider Mode for E1
000 = Not valid
001 = Divide by DIV_E1 = 3
010 = Divide by DIV_E1 = 4 1/6
011 = Divide by DIV_E1 = 4
100 = Divide by DIV_E1 = 5.5
101 = Divide by DIV_E1 = 5 1/3
110 = Divide by DIV_E1 = 5 2/3
111 = Not valid
Data Sheet
277
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Global Clock Mode Register 3 (Read/Write)
Value after reset: 00H
7
GCM3
0
PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1
7
6
5
4
3
2
1
0
PHD_T1(7:0)
(94)
Frequency Adjust for T1
For details see calculation formulas below.
Global Clock Mode Register 4 (Read/Write)
Value after reset: 00H
7
GCM4
0
DVM_T1 DVM_T1 DVM_T1
2
1
0
PHD_T1(8:11)
0
PHD_T1 PHD_T1 PHD_T1 PHD_T1
11
10
9
8
(95)
Frequency Adjust for T1
For details see calculation formulas below.
DVM_T1(0:2)
Divider Mode for T1
000 = Not valid
001 = Divide by DIV_T1 = 3
010 = Divide by DIV_T1 = 4 1/6
011 = Divide by DIV_T1 = 4
100 = Divide by DIV_T1 = 5.5
101 = Divide by DIV_T1 = 5 1/3
110 = Divide by DIV_T1 = 5 2/3
111 = Not valid
GCM4.4
Reserved
Must be cleared.
Data Sheet
278
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Global Clock Mode Register 5 (Read/Write)
Value after reset: 00H
7
GCM5
0
MCLK_
LOW
MCLK_LOW
PLL_M(4:0)
PLL_M
4
PLL_M
3
PLL_M
2
PLL_M
1
PLL_M
0
(96)
Master Clock Range Low
0=
Master clock frequency divided by (PLL_M+1) is greater than or
equal 1.5 MHz
1=
Master clock frequency divided by (PLL_M+1) is less than 1.5
MHz
PLL Dividing Factor M
For details see calculation formulas below.
Note: Write operations to GCM5 initiate a PLL reset (see below).
Global Clock Mode Register 6 (Read/Write)
Value after reset: 00H
7
GCM6
PLL_N(4:0)
0
PLL_N
4
PLL_N
3
PLL_N
2
PLL_N
1
PLL_N
0
(97)
PLL Dividing Factor N
For details see calculation formulas below.
Note: Write operations to GCM6 initiate a PLL reset (see below).
Data Sheet
279
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Flexible Clock Mode Settings
If flexible master clock mode is used (VFREQ_EN = 1), the according register settings
can be calculated as follows (a windows-based program for automatic calculation is
available, see Chapter 13.3 on page 481). For some of the standard frequencies see
the table below.
1. PLL_M and PLL_N must fulfill the equations:
a. 1.5 MHz ≤ fMCLK / (PLL_M+1) ≤ 2.048 MHz
b. If (a.) is not possible, set MCLK_LOW and fulfill
1.02 MHz ≤ fMCLK / (PLL_M+1) ≤ 1.5 MHz
c. 65 MHz ≤ fMCLK × (2×PLL_N+2) / (PLL_M+1) ≤ 69.7 MHz
(as high as possible within this range)
2. Selection of dividing mode to best fulfill:
foutE1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_E1 (target E1: 16.384 MHz)
foutT1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_T1 (target T1: 12.352 MHz)
Though the target frequency might not be met directly, the dividing mode has to be
selected to reach a frequency, which is as near as possible to the target frequency.
3. Calculation of correction value (frequency mismatch correction)
PHD_E1 = 6 × 4096 × [DIV_E1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/16.384 MHz)]
PHD_T1 = 6 × 4096 × [DIV_T1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/12.352 MHz)]
The result of these equations will be in the range of -2048 to +2047. Negative values are
represented in 2s-complement format (e.g. -2000D = 830H; +2000D = 7D0H).
Table 60
Clock Mode Register Settings for E1 or T1/J1
fMCLK [MHz]
GCM1
GCM2
GCM3
GCM4
GCM5
GCM6
1.544
F0H
51H
00H
80H
00H
15H
2.048
00H
58H
D2H
C2H
00H
10H
8.192
00H
58H
D2H
C2H
03H
10H
10.000
90H
51H
81H
8FH
04H
10H
12.352
F0H
51H
00H
80H
07H
15H
Data Sheet
280
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Transmit FIFO 2 (Write)
Value after reset: 00H
7
0
XFIFO2
XF7
XF0
(x9C)
XFIFO2
XF15
XF8
(x9D)
XF(15:0)
Transmit FIFO for HDLC Channel 2
The function is equivalent to XFIFO.
Transmit FIFO 3 (Write)
Value after reset: 00H
7
0
XFIFO3
XF7
XF0
(x9E)
XFIFO3
XF15
XF8
(x9F)
XF(15:0)
Transmit FIFO for HDLC Channel 3
The function is equivalent to XFIFO.
Time Slot Even/Odd Select (Read/Write)
Value after reset: 00H
7
TSEO
0
EO31
EO30
EO21
EO20
EO11
EO10
(A0)
HDLC protocol data can be sent in even, odd or both frames of a multiframe. Even
frames are frame number 2, 4,and so on, odd frames are frame number 1, 3, and so on.
The selection refers to receive and transmit direction as well. Each multiframe starts with
an odd frame and ends with an even frame. By default all frames are used for HDLC
reception and transmission.
Note: The different HDLC channels have to be configured to use different time slots, bit
positions or frames.
Data Sheet
281
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
EO1(1:0)
Even/Odd frame selection HDLC Channel 1
Channel 1 HDLC protocol data can be sent in even, odd or both
frames of a multiframe.
00 = Even and odd frames
01 = Odd frames only
10 = Even frames only
11 = Undefined
EO2(1:0)
Even/Odd frame selection HDLC Channel 2
Channel 2 HDLC protocol data can be sent in even, odd or both
frames of a multiframe.
00 = Even and odd frames
01 = Odd frames only
10 = Even frames only
11 = Undefined
EO3(1:0)
Even/Odd frame selection HDLC Channel 3
Channel 3 HDLC protocol data can be sent in even, odd or both
frames of a multiframe.
00 = Even and odd frames
01 = Odd frames only
10 = Even frames only
11 = Undefined
Time Slot Bit Select 1 (Read/Write)
Value after reset: FFH
7
TSBS1
TSB17
TSB1(7:0)
0
TSB16
TSB15
TSB14
TSB13
TSB12
TSB11
TSB10
(A1)
Time Slot Bit Selection - HDLC Channel 1
Only bits selected by this register are used for HDLC channel 1 in
selected time slots. Time slot selection is done by setting the
appropriate bits in registers TTR(4:1) and RTR(4:1) independently
for receive and transmit direction. Bit selection is common to receive
and transmit direction. By default all bit positions within the selected
time slot(s) are enabled.
0 = Bit position x in selected time slot(s) is not used for HDLC
channel 1 reception and transmission.
Data Sheet
282
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
1 = Bit position x in selected time slot(s) is used for HDLC channel
1 reception and transmission.
Time Slot Bit Select 2 (Read/Write)
Value after reset: FFH
7
TSBS2
TSB27
TSB2(7:0)
0
TSB26
TSB25
TSB24
TSB23
TSB22
TSB21
TSB20
(A2)
Time Slot Bit Selection - HDLC Channel 2
Only bits selected by this register are used for HDLC channel 2 in
selected time slots. Time slot selection is done by setting the
appropriate bits in register TSS2. Bit selection is common to receive
and transmit direction. By default all bit positions within the selected
time slot are enabled.
0 = Bit position x in selected time slot(s) is not used for HDLC
channel 2 reception and transmission.
1 = Bit position x in selected time slot(s) is used for HDLC channel
2 reception and transmission.
Time Slot Bit Select 3 (Read/Write)
Value after reset: FFH
7
TSBS3
TSB37
TSB3(7:0)
0
TSB36
TSB35
TSB34
TSB33
TSB32
TSB31
TSB30
A3)
Time Slot Bit Selection - HDLC Channel 3
Only bits selected by this register are used for HDLC channel 3 in
selected time slots. Time slot selection is done by setting the
appropriate bits in register TSS3. Bit selection is common to receive
and transmit direction. By default all bit positions within the selected
time slot are enabled.
0 = Bit position x in selected time slot(s) is not used for HDLC
channel 3 reception and transmission.
1 = Bit position x in selected time slot(s) is used for HDLC channel
3 reception and transmission.
Data Sheet
283
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Time Slot Select 2 (Read/Write)
Value after reset: 00H
7
0
TSS2
TSS24
TSS2(4:0)
TSS23
TSS22
TSS21
TSS20
(A4)
Time Slot Selection Code - HDLC Channel 2
Defines the time slot used by HDLC channel 2.
00000 =No time slot selected
00001 =Time slot 1
...
11111 =Time slot 31
Note:Different HDLC channels must use different time slots.
Time Slot Select 3 (Read/Write)
Value after reset: 00H
7
0
TSS3
TSB3(4:0)
TSS34
TSS33
TSS32
TSS31
TSS30
(A5)
Time Slot Selection Code - HDLC Channel 3
Defines the time slot used by HDLC channel 3.
00000 =No time slot selected
00001 =Time slot 1
...
11111 =Time slot 31
Note:Different HDLC channels must use different time slots.
Data Sheet
284
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Test Pattern Control Register 0 (Read/Write)
Value after reset: 00H
7
0
TPC0
FRA
(A8)
FRA
Framed/Unframed Selection
0 = PRBS is generated/monitored unframed.
Framing information is overwritten by the generator.
1=
Data Sheet
PRBS is generated/monitored framed.
Time slot 0 is not overwritten by the generator and not observed
by the monitor.
285
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
9.3
E1 Status Register Addresses
Table 61
E1 Status Register Address Arrangement
Address
Register
Type Comment
Page
00
RFIFO
R
Receive FIFO
289
01
RFIFO
R
Receive FIFO
289
49
RBD
R
Receive Buffer Delay
289
4A
VSTR
R
Version Status Register
290
4B
RES
R
Receive Equalizer Status
290
4C
FRS0
R
Framer Receive Status 0
291
4D
FRS1
R
Framer Receive Status 1
294
4E
RSW
R
Receive Service Word
295
4F
RSP
R
Receive Spare Bits
296
50
FECL
R
Framing Error Counter Low
298
51
FECH
R
Framing Error Counter High
298
52
CVCL
R
Code Violation Counter Low
299
53
CVCH
R
Code Violation Counter High
299
54
CEC1L
R
CRC Error Counter 1 Low
300
55
CEC1H
R
CRC Error Counter 1 High
300
56
EBCL
R
E-Bit Error Counter Low
301
57
EBCH
R
E-Bit Error Counter High
301
58
CEC2L
R
CRC Error Counter 2 Low
302
59
CEC2H
R
CRC Error Counter 2 High
302
5A
CEC3L
R
CRC Error Counter 3 Low
303
5B
CEC3H
R
CRC Error Counter 3 High
303
5C
RSA4
R
Receive Sa4-Bit Register
304
5D
RSA5
R
Receive Sa5-Bit Register
304
5E
RSA6
R
Receive Sa6-Bit Register
304
5F
RSA7
R
Receive Sa7-Bit Register
304
60
RSA8
R
Receive Sa8-Bit Register
304
61
RSA6S
R
Receive Sa6-Bit Status Register
305
62
RSP1
R
Receive Signaling Pointer 1
306
63
RSP2
R
Receive Signaling Pointer 2
306
Data Sheet
286
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Table 61
E1 Status Register Address Arrangement (cont’d)
Address
Register
Type Comment
Page
64
SIS
R
Signaling Status Register
307
65
RSIS
R
Receive Signaling Status Register
308
66
RBCL
R
Receive Byte Control Low
310
67
RBCH
R
Receive Byte Control High
310
68
ISR0
R
Interrupt Status Register 0
310
69
ISR1
R
Interrupt Status Register 1
312
6A
ISR2
R
Interrupt Status Register 2
314
6B
ISR3
R
Interrupt Status Register 3
316
6C
ISR4
R
Interrupt Status Register 4
317
6D
ISR5
R
Interrupt Status Register 5
319
6E
GIS
R
Global Interrupt Status
321
70
RS1
R
Receive CAS Register 1
322
71
RS2
R
Receive CAS Register 2
322
72
RS3
R
Receive CAS Register 3
322
73
RS4
R
Receive CAS Register 4
322
74
RS5
R
Receive CAS Register 5
322
75
RS6
R
Receive CAS Register 6
322
76
RS7
R
Receive CAS Register 7
322
77
RS8
R
Receive CAS Register 8
322
78
RS9
R
Receive CAS Register 9
322
79
RS10
R
Receive CAS Register 10
322
7A
RS11
R
Receive CAS Register 11
322
7B
RS12
R
Receive CAS Register 12
322
7C
RS13
R
Receive CAS Register 13
322
7D
RS14
R
Receive CAS Register 14
322
7E
RS15
R
Receive CAS Register 15
322
7F
RS16
R
Receive CAS Register 16
322
90
RBC2
R
Receive Byte Count Register 2
323
91
RBC3
R
Receive Byte Count Register 3
323
98
SIS2
R
Signaling Status Register 2
323
Data Sheet
287
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Table 61
E1 Status Register Address Arrangement (cont’d)
Address
Register
Type Comment
99
RSIS2
R
Receive Signaling Status Register 2 325
9A
SIS3
R
Signaling Status Register 3
9B
RSIS3
R
Receive Signaling Status Register 3 327
9C
RFIFO2
R
Receive FIFO 2
329
9D
RFIFO2
R
Receive FIFO 2
329
9E
RFIFO3
R
Receive FIFO 3
329
9F
RFIFO3
R
Receive FIFO 3
329
EC
WID
R
Identification Register
329
Data Sheet
288
Page
326
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
9.4
Detailed Description of E1 Status Registers
Receive FIFO - HDLC Channel 1 (Read)
7
0
RFIFO
RF7
RF0
(00)
RFIFO
RF15
RF8
(01)
Reading data from RFIFO of HDLC channel 1 can be done in an 8-bit (byte) or 16-bit
(word) access depending on the selected bus interface mode. The LSB is received first
from the serial interface.
The size of the accessible part of RFIFO is determined by programming the bits
CCR1.RFT(1:0) (RFIFO threshold level). It can be reduced from 32 bytes (reset value)
down to 2 bytes (four values: 32, 16, 4, 2 bytes).
Data Transfer
Up to 32 bytes/16 words of received data can be read from the RFIFO following an RPF
or an RME interrupt.
RPF Interrupt: A fixed number of bytes/words to be read (32, 16, 4, 2 bytes). The
message is not yet complete.
RME Interrupt: The message is completely received. The number of valid bytes is
determined by reading the RBCL, RBCH registers.
RFIFO is released by issuing the RMC (Receive Message Complete) command.
Receive Buffer Delay (Read)
7
RBD
RBD(5:0)
0
RBD5
RBD4
RBD3
RBD2
RBD1
RBD0
(49)
Receive Elastic Buffer Delay
These bits informs the user about the current delay (in time slots)
through the receive elastic buffer. The delay is updated every 512 or
256 bits (SIC1.RBS(1:0)). Before reading this register the user has to
set bit DEC.DRBD in order to halt the current value of this register.
After reading RBD updating of this register is enabled. Not valid if the
receive buffer is bypassed.
000000 = Delay < 1 time slot
...
111111 = Delay > 63 time slots
Data Sheet
289
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Version Status Register (Read)
VSTR
7
0
VN7
VN0
VN(7:0)
(4A)
Version Number of Chip
00H =Version 1.2
Receive Equalizer Status (Read)
7
RES
EV(1:0)
EV1
0
EV0
RES4
RES3
RES2
RES1
RES0
(4B)
Equalizer Status Valid
These bits informs the user about the current state of the receive
equalization network. Only valid if LIM1.EQON is set.
00 = Equalizer status not valid, still adapting
01 = Equalizer status valid
10 = Equalizer status not valid
11 = Equalizer status valid but high noise floor
RES(4:0)
Receive Equalizer Status
The current line attenuation status in steps of about 1.7 dB are
displayed in these bits. Only valid if bits EV(1:0) = 01 and
LIM1.EQON = 1. Accuracy: ± 2 digits, based on temperature
influence and noise amplitude variations.
00000 = Minimum attenuation: 0 dB
...
11001 = Maximum attenuation: -43 dB
Data Sheet
290
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Framer Receive Status Register 0 (Read)
7
FRS0
LOS
LOS
0
AIS
LFA
RRA
NMF
LMFA
(4C)
Loss-of-Signal
Detection:
This bit is set when the incoming signal has “no transitions” (analog
interface) or logical zeros (digital interface) in a time interval of T
consecutive pulses, where T is programmable by register PCD.
Total account of consecutive pulses: 16 < T < 4096.
Analog interface: The receive signal level where “no transition” is
declared is defined by the programmed value of LIM1.RIL(2:0).
Recovery:
Analog interface: The bit is reset in short-haul mode when the
incoming signal has transitions with signal levels greater than the
programmed receive input level (LIM1.RIL(2:0)) for at least M pulse
periods defined by register PCR in the PCD time interval. In long-haul
mode additionally bit RES.6 must be set for at least 250µsec.
Digital interface: The bit is reset when the incoming data stream
contains at least M ones defined by register PCR in the PCD time
interval.
With the rising edge of this bit an interrupt status bit (ISR2.LOS) is set.
The bit is also set during alarm simulation and reset, if FMR0.SIM is
cleared and no alarm condition exists.
AIS
Alarm Indication Signal
The function of this bit is determined by FMR0.ALM.
FMR0.ALM = 0: This bit is set when two or less zeros in the received
bit stream are detected in a time interval of 250 µs and the FALC56 is
in asynchronous state (FRS0.LFA = 1). The bit is reset when no
alarm condition is detected (according to ETSI standard).
FMR0.ALM = 1: This bit is set when the incoming signal has two or
less Zeros in each of two consecutive double frame period (512 bits).
This bit is cleared when each of two consecutive doubleframe periods
contain three or more zeros or when the frame alignment signal FAS
has been found. (ITU-T G.775)
The bit is also set during alarm simulation and reset if FMR0.SIM is
cleared and no alarm condition exists.
With the rising edge of this bit an interrupt status bit (ISR2.AIS) is set.
Data Sheet
291
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
LFA
Loss of Frame Alignment
This bit is set after detecting 3 or 4 consecutive incorrect FAS words
or 3 or 4 consecutive incorrect service words (can be disabled). With
the rising edge of this bit an interrupt status bit (ISR2.LFA) is set. The
specification of the loss of synchronization conditions is done by bits
RC0.SWD and RC0.ASY4. After loss of synchronization, the frame
aligner resynchronizes automatically.
The following conditions have to be detected to regain synchronous
state:
– The presence of the correct FAS word in frame n.
– The presence of the correct service word (bit 2 = 1) in frame n+1.
– For a second time the presence of a correct FAS word in frame
n+2.
The bit is cleared when synchronization has been regained (directly
after the second correct FAS word of the procedure described above
has been received).
If the CRC-multiframe structure is enabled by setting bit FMR2.RFS1,
multiframe alignment is assumed to be lost if pulseframe
synchronization has been lost. The resynchronization procedure for
multiframe alignment starts after the bit FRS0.LFA has been cleared.
Multiframe alignment has been regained if two consecutive CRCmultiframes have been received without a framing error (refer to
FRS0.LMFA).
The bit is set during alarm simulation and reset if FMR0.SIM is
cleared and no alarm condition exists.
If bit FRS0.LFA is cleared a loss of frame alignment recovery interrupt
status ISR2.FAR is generated.
RRA
Receive Remote Alarm
Set if bit 3 of the received service word is set. An alarm interrupt status
ISR2.RA can be generated if the alarm condition is detected.
FRS0.RRA is cleared if no alarm is detected. At the same time a
remote alarm recovery interrupt status ISR2.RAR is generated.
The bit RSW.RRA has the same function.
Both status and interrupt status bits are set during alarm simulation.
Data Sheet
292
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
NMF
No Multiframe Alignment Found
This bit is only valid if the CRC4 interworking is selected
(FMR2.RFS(1:0) = 11). Set if the multiframe pattern is not detected in
a time interval of 400 ms after the framer has reached the
doubleframe synchronous state. The receiver is then automatically
switched to doubleframe format.
This bit is reset if the basic framing has been lost.
LMFA
Loss of Multiframe Alignment
Not used in doubleframe format (FMR2.RFS1 = 0). In this case LMFA
is set.
In CRC-multiframe mode (FMR2.RFS1 = 1), this bit is set
– if force resynchronization is initiated by setting bit FMR0.FRS, or
– if multiframe force resynchronization is initiated by setting bit
FMR1.MFCS, or
– if pulseframe alignment has been lost (FRS0.LFA).
It is reset if two CRC-multiframes have been received at an interval of
n × 2 ms (n = 1, 2, 3 and so forth) without a framing error.
If bit FRS0.LMFA is cleared a loss of multiframe alignment recovery
interrupt status ISR2.MFAR is generated.
Data Sheet
293
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Framer Receive Status Register 1 (Read)
7
FRS1
EXZD
EXZD
0
TS16RA TS16LOS TS16AIS TS16LFA
XLS
XLO
(4D)
Excessive Zeros Detected
Significant only, if excessive zero detection has been enabled
(FMR0.EXZE = 1). Set after detection of more than 3 (HDB3 code) or
15 (AMI code) contiguous zeros in the received data stream.
This bit is cleared on read.
TS16RA
Receive Time Slot 16 Remote Alarm
This bit contains the actual information of the received remote alarm
bit RS1.2 in time slot 16. Setting and resetting of this bit causes an
interrupt status change ISR3.RA16.
TS16LOS
Receive Time Slot 16 Loss-of-Signal
This bit is set if the incoming TS16 data stream contains always zeros
for at least 16 contiguously received time slots. A one in a time slot 16
resets this bit.
TS16AIS
Receive Time Slot 16 Alarm Indication Signal
The detection of the alarm indication signal in time slot 16 is according
to ITU-T G.775.
This bit is set if the incoming TS16 contains less than 4 zeros in each
of two consecutive TS16 multiframe periods. This bit is cleared if two
consecutive received CAS multiframe periods contains more than 3
zeros or the multiframe pattern was found in each of them. This bit is
cleared if TS0 synchronization is lost.
TS16LFA
Data Sheet
Receive Time Slot 16 Loss of Multiframe Alignment
0=
The CAS controller is in synchronous state after frame
alignment is accomplished.
1=
This bit is set if the framing pattern "0000" in 2 consecutive CAS
multiframes were not found or in all TS16 of the preceding
multiframe all bits were reset. An interrupt ISR3.LMFA16 is
generated.
294
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XLS
Transmit Line Short
Significant only if the ternary line interface is selected by
LIM1.DRS = 0.
XLO
0=
Normal operation. No short is detected.
1=
The XL1 and XL2 are shortened for at least 3 pulses. As a
reaction of the short the pins XL1 and XL2 are automatically
forced into a high-impedance state if bit XPM2.DAXLT is reset.
After 128 consecutive pulse periods the outputs XL1/2 are
activated again and the internal transmit current limiter is
checked. If a short between XL1/2 is still further active the
outputs XL1/2 are in high-impedance state again. When the
short disappears pins XL1/2 are activated automatically and
this bit is reset. With any change of this bit an interrupt
ISR1.XLSC is generated. In case of XPM2.XLT is set this bit is
frozen.
Transmit Line Open
0=
Normal operation
1=
This bit is set if at least 32 consecutive zeros were sent on pins
XL1/XL2 or XDOP/XDON. This bit is reset with the first
transmitted pulse. With the rising edge of this bit an interrupt
ISR1.XLSC is set. In case of XPM2.XLT is set this bit is frozen.
Receive Service Word Pulseframe (Read)
7
RSW
RSI
RSI
0
RRA
RY0
RY1
RY2
RY3
RY4
(4E)
Receive Spare Bit for International Use
First bit of the received service word. It is fixed to one if CRCmultiframe mode is enabled.
RRA
Receive Remote Alarm
Equivalent to bit FRS0.RRA.
RY(4:0)
Data Sheet
Receive Spare Bits for National Use (Y-Bits, Sn-Bits, Sa-Bits)
295
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Spare Bits/Additional Status (Read)
7
RSP
SI(2:1)
SI1
0
SI2
LLBDD
LLBAD
RSIF
RS13
RS15
(4F)
Submultiframe Error Indication 1, 2
Not valid if doubleframe format is enabled. In this case, both bits are
set.
When using CRC-multiframe format these bits are set to
0=
If multiframe alignment has been lost, or if the last multiframe
has been received with CRC error(s).
SI1 flags a CRC error in last submultiframe 1, SI2 flags a CRC
error in last submultiframe 2.
1=
If at multiframe synchronous state last assigned submultiframe
has been received without a CRC error.
Both flags are updated with the beginning of every received CRC
multiframe.
If automatic transmission of submultiframe status is enabled by
setting bit XSP.AXS, above status information is inserted
automatically in Si-bit position of every outgoing CRC multiframe
(under the condition that time slot 0 transparent modes are both
disabled):
SI1 → Si -bit of frame 13, SI2 → Si -bit of frame 15.
LLBDD
Line Loop-Back Deactivation Signal Detected
This bit is set in case of the LLB deactivate signal is detected and then
received over a period of more than 25 ms with a bit error rate less
than 10-2. The bit remains set as long as the bit error rate does not
exceed 10-2.
If framing is aligned, the time slot 0 is not taken into account for the
error rate calculation.
Any change of this bit causes an LLBSC interrupt.
LLBAD
Line Loop-Back Activation Signal Detected
Depending on bit LCR1.EPRM the source of this status bit changed.
LCR1.EPRM = 0: This bit is set in case of the LLB activate signal is
detected and then received over a period of more than 25 ms with a
bit error rate less than 10-2. The bit remains set as long as the bit error
rate does not exceed 10-2.
Data Sheet
296
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
If framing is aligned, the time slot 0 is not taken into account for the
error rate calculation.
Any change of this bit causes an LLBSC interrupt.
PRBS Status
LCR1.EPRM = 1: The current status of the PRBS synchronizer is
indicated in this bit. It is set high if the synchronous state is reached
even in the presence of a bit error rate of 10-1. A data stream
containing all zeros or all ones with/without framing bits is also a valid
pseudo-random binary sequence.
RSIF
Receive Spare Bit for International Use (FAS Word)
First bit in FAS-word. Used only in doubleframe format, otherwise
fixed to "1".
RS13
Receive Spare Bit (Frame 13, CRC Multiframe)
First bit in service word of frame 13. Significant only in CRCmultiframe format, otherwise fixed to "0". This bit is updated with
beginning of every received CRC multiframe.
RS15
Receive Spare Bit (Frame 15, CRC Multiframe)
First bit in service word of frame 15. Significant only in CRCmultiframe format, otherwise fixed to "0". This bit is updated with
beginning of every received CRC multiframe.
Data Sheet
297
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Framing Error Counter (Read)
FECL
FECH
FE(15:0)
7
0
FE7
FE0
7
0
FE15
FE8
(50)
(51)
Framing Errors
This 16-bit counter is incremented when a FAS word has been
received with an error.
Framing errors are counted during basic frame synchronous state
only (but even if multiframe synchronous state is not reached yet).
During alarm simulation, the counter is incremented every 250 µs up
to its saturation. The error counter does not roll over.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DFEC has
to be set. With the rising edge of this bit updating the buffer is stopped
and the error counter is reset. Bit DEC.DFEC is reset automatically
with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
298
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Code Violation Counter (Read)
CVCL
CVCH
CV(15:0)
7
0
CV7
CV0
7
0
CV15
CV8
(52)
(53)
Code Violations
No function if NRZ code has been enabled.
If the HDB3 or the CMI code with HDB3-precoding is selected, the 16bit counter is incremented when violations of the HDB3 code are
detected. The error detection mode is determined by programming
the bit FMR0.EXTD.
If simple AMI coding is enabled (FMR0.RC0/1 = 10) all bipolar
violations are counted. The error counter does not roll over.
During alarm simulation, the counter is incremented every four bits
received up to its saturation.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCVC
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DCVC is reset
automatically with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
299
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
CRC Error Counter 1 (Read)
CEC1L
CEC1H
CR(15:0)
7
0
CR7
CR0
7
0
CR15
CR8
(54)
(55)
CRC Errors
No function if doubleframe format is selected.
In CRC-multiframe mode, the 16-bit counter is incremented when a
CRC-submultiframe has been received with a CRC error. CRC errors
are not counted during asynchronous state. The error counter does
not roll over.
During alarm simulation, the counter is incremented once per
submultiframe up to its saturation.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCEC1
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DCEC1 is reset
automatically with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
300
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
E-Bit Error Counter (Read)
EBCL
EBCH
EB(15:0)
7
0
EB7
EB0
7
0
EB15
EB8
(56)
(57)
E-Bit Errors
If doubleframe format is selected, FEBEH/L has no function. If CRCmultiframe mode is enabled, FEBEH/L works as submultiframe error
indication counter (16 bits) which counts zeros in Si-bit position of
frame 13 and 15 of every received CRC multiframe. The error counter
does not roll over.
During alarm simulation, the counter is incremented once per
submultiframe up to its saturation.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DEBC
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DEBC is reset
automatically with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
301
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
CRC Error Counter 2 (Read)
CEC2L
CEC2H
CC(15:0)
7
0
CC7
CC0
7
0
CC15
CC8
(58)
(59)
CRC Error Counter (reported from TE through Sa6 -Bit)
Depending on bit LCR1.EPRM the error counter increment is
selected:
LCR1.EPRM = 0:
If doubleframe format is selected, CEC2H/L has no function. If CRCmultiframe mode is enabled, CEC2H/L works as Sa6-bit error
indication counter (16 bits) which counts the Sa6-bit sequence 0001
and 0011in every received CRC submultiframe.
Incrementing the counter is only possible in the multiframe
synchronous state FRS0.LMFA = 0.
Sa6-bit sequence: SA61, SA62, SA63, SA64 = 0001 or 0011 where
SA61 is received in frame 1 or 9 in every multiframe.
During alarm simulation, the counter is incremented once per
submultiframe up to its saturation.
Pseudo-Random Binary Sequence Error Counter
LCR1.EPRM = 1:
This 16-bit counter is incremented with every received PRBS bit error
in the PRBS synchronous state RSP.LLBAD = 1. The error counter
does not roll over.
During alarm simulation, the counter is incremented continuously with
every second received bit.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCEC2
has to be set. With the rising edge of this bit updating of the buffer is
stopped and the error counter is reset. Bit DEC.DCEC2 is reset
automatically with reading the error counter high byte.
Data Sheet
302
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then reset automatically. The latched error
counter state should be read within the next second.
CRC Error Counter 3 (Read)
CEC3L
CEC3H
CE(15:0)
7
0
CE7
CE0
7
0
CE15
CE8
(5A)
(5B)
CRC Error Counter (detected at T Reference Point in Sa6 -Bit)
GCR.ECMC = 0: If doubleframe format is selected, CEC3H/L has no
function. If CRC-multiframe mode is enabled, CEC3H/L works as Sa6bit error indication counter (16 bits) which counts the Sa6-bit
sequence 0010 and 0011in every received CRC submultiframe.
Incrementing the counter is only possible in the multiframe
synchronous state FRS0.LMFA = 0.
Sa6-bit sequence: SA61, SA62, SA63, SA64 = 0010 or 0011 where
SA61 is received in frame 1 or 9 in every multiframe. The error
counter does not roll over.
During alarm simulation, the counter is incremented once per
submultiframe up to its saturation.
CE(7:2)
Multiframe Counter
GCR.ECMC = 1: This 6 bit counter increments with each multiframe
period in the asynchronous state FRS0.LFA/LMFA = 1.
During alarm simulation, the counter is incremented once per
multiframe up to its saturation.
CE(1:0)
Change of Frame Alignment Counter
GCR.ECMC = 1: This 2 bit counter increments with each detected
change of frame/multiframe alignment. The error counter does not roll
over.
During alarm simulation, the counter is incremented once per
multiframe up to its saturation.
Clearing and updating the counter is done according to bit
FMR1.ECM.
Data Sheet
303
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCEC3
has to be set. With the rising edge of this bit updating of the buffer is
stopped and the error counter is reset. Bit DEC.DCEC3 is reset
automatically with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Receive Sa4-Bit Register (Read)
7
0
RSA4
RS47
RS40
(5C)
RSA5
RS57
RS50
(5D)
RSA6
RS67
RS60
(5E)
RSA7
RS77
RS70
(5F)
RSA8
RS87
RS80
(60)
RS4(7:0)
Receive Sa4-Bit Data (Y-Bits)
RS5(7:0)
Receive Sa5-Bit Data
RS6(7:0)
Receive Sa6-Bit Data
RS7(7:0)
Receive Sa7-Bit Data
RS8(7:0)
Receive Sa8-Bit Data
This register contains the information of the eight Sax bits (x = 4 to 8)
of the previously received CRC multiframe. These registers are
updated with every multiframe begin interrupt ISR0.RMB.
RS40 is received in bit-slot 4 of every service word in frame 1, RS47
in frame 15
RS50 is received in bit-slot 5, time slot 0, frame 1, RS57 in frame 15
RS60 is received in bit-slot 6, time slot 0, frame 1, RS67 in frame 15
RS70 is received in bit-slot 7, time slot 0, frame 1, RS77 in frame 15
RS80 is received in bit-slot 8, time slot 0, frame 1, RS87 in frame 15
Valid if CRC multiframe format is enabled by setting bits
FMR2.RFS1 = 1 or FMR2.RFS(1:0) = 01 (doubleframe format).
Data Sheet
304
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Sa6-Bit Status (Read)
7
RSA6S
0
S_X
S_F
S_E
S_C
S_A
S_8
(61)
Four consecutive received Sa6-bits are checked on the by
ETS300233 defined Sa6-bit combinations. The FALC56 detects the
following “fixed” Sa6-bit combinations:
SA61, SA62, SA63, SA64 = 1000, 1010, 1100, 1110, 1111. All other
possible 4 bit combinations are grouped to status “X”.
A valid Sa6-bit combination must occur three times in a row. The
corresponding status bit in this register is set. Even if the detected
status is active for a short time the status bit remains active until this
register is read. Reading the register resets all pending status
information.
With any change of state of the Sa6-bit combinations an interrupt
status ISR0.SA6SC is generated.
During the basic frame asynchronous state updating of this register
and interrupt status ISR0.SA6SC is disabled. In multiframe format the
detection of the Sa6-bit combinations can be done either synchronous
or asynchronous to the submultiframe (FMR3.SA6SY). In
synchronous detection mode updating of register RSA6S is done in
the multiframe synchronous state (FRS0.LMFA = 0). In
asynchronous detection mode updating is independent to the
multiframe synchronous state.
S_X
Receive Sa6-Bit Status_X
If none of the fixed Sa6-bit combinations are detected this bit is set.
S_F
Receive Sa6-Bit Status: "1111"
Receive Sa6-bit status “1111” is detected for three times in a row in
the Sa6-bit positions.
S_E
Receive Sa6-Bit Status: "1110"
Receive Sa6-bit status “1110” is detected for three times in a row in
the Sa6-bit positions.
S_C
Receive Sa6-Bit Status: "1100"
Receive Sa6-bit status “1100” is detected for three times in a row in
the Sa6bit positions.
Data Sheet
305
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
S_A
Receive Sa6-Bit Status: "1010"
Receive Sa6-bit status “1010” is detected for three times in a row in
the Sa6-bit positions.
Receive Sa6-Bit Status: "1000"
S_8
Receive Sa6-bit status “1000” is detected for three times in a row in
the Sa6-bit positions.
Receive Signaling Pointer 1 (Read)
Value after reset: 00H
7
RSP1
RS8C
RS(8:1)C
0
RS7C
RS6C
RS5C
RS4C
RS3C
RS2C
RS1C
(62)
Receive Signaling Register RS(8:1) Changed
A one in each bit position indicates that the received signaling data in
the corresponding RS(8:1) registers are updated. Bit RS1C is the
pointer for register RS1, while RS8C points to RS8.
Receive Signaling Pointer 2 (Read)
Value after reset: 00H
7
RSP2
RS16C
RS(16:9)C
0
RS15C
RS14C
RS13C
RS12C
RS11C
RS10C
RS9C
(63)
Receive Signaling Register RS9-16 Changed
A one in each bit position indicates that the received signaling data in
the corresponding RS9-16 registers are updated. Bit RS9C is the
pointer for register RS9, while RS16C points to RS16.
Data Sheet
306
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Signaling Status Register (Read)
7
SIS
XDOV
XDOV
0
XFW
XREP
RLI
CEC
SFS
(64)
Transmit Data Overflow - HDLC Channel 1
More than 32 bytes have been written to the XFIFO.
This bit is reset
– by a transmitter reset command XRES
– when all bytes in the accessible half of the XFIFO have been moved
in the inaccessible half.
XFW
Transmit FIFO Write Enable - HDLC Channel 1
Data can be written to the XFIFO.
XREP
Transmission Repeat - HDLC Channel 1
Status indication of CMDR.XREP.
RLI
Receive Line Inactive - HDLC Channel 1
Neither flags as interframe time fill nor frames are received through
the signaling time slot.
CEC
Command Executing - HDLC Channel 1
0=
No command is currently executed, the CMDR register can be
written to.
1=
A command (written previously to CMDR) is currently executed,
no further command can be temporarily written in CMDR
register.
Note: CEC is active for about 2.5 periods of the current system data
rate.
SFS
Data Sheet
Status Freeze Signaling
0=
Freeze signaling status inactive.
1=
Freeze signaling status active
307
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Signaling Status Register (Read)
7
RSIS
VFR
0
RDO
CRC16
RAB
HA1
HA0
LA
(65)
RSIS relates to the last received HDLC frame; it is copied into RFIFO when end-of-frame
is recognized (last byte of each stored frame).
VFR
Valid Frame - HDLC Channel 1
Determines whether a valid frame has been received.
1=
Valid
0=
Invalid
An invalid frame is either
– a frame which is not an integer number of 8 bits (n×8 bits) in length
(e.g. 25 bits), or
– a frame which is too short taking into account the operation mode
selected by MODE (MDS(2:0)) and the selection of receive CRC
on/off (CCR2.RCRC) as follows:
• MDS(2:0) = 011 (16 bit Address),
RCRC = 0: 4 bytes; RCRC = 1: 3 or 4 bytes
• MDS(2:0) = 010 (8 bit Address),
RCRC = 0: 3 bytes; RCRC = 1: 2 or 3 bytes
Note:Shorter frames are not reported.
RDO
Receive Data Overflow - HDLC Channel 1
A RFIFO data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated (refer to ISR1.RDO/
IMR1.RDO).
CRC16
RAB
CRC16 Compare/Check - HDLC Channel 1
0=
CRC check failed; received frame contains errors.
1=
CRC check o.k.; received frame is error-free.
Receive Message Aborted - HDLC Channel 1
This bit is set in SS7 mode, if the maximum number of octets (272+7)
is exceeded. The received frame was aborted from the transmitting
station. According to the HDLC protocol, this frame must be discarded
by the receiver station.
Data Sheet
308
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
HA1, HA0
High Byte Address Compare - HDLC Channel 1
Significant only if 2-byte address mode or SS7 mode has been
selected.
In operating modes which provide high byte address recognition, the
FALC56 compares the high byte of a 2-byte address with the contents
of two individually programmable registers (RAH1, RAH2) and the
fixed values FEH and FCH (broadcast address).
Depending on the result of this comparison, the following bit
combinations are possible (SS7 support not active):
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R = 0 (bit 1)
11 = RAH1 has been recognized C/R = 1 (bit 1)
Note: If RAH1, RAH2 contain identical values, a match is indicated
by "10" or "11".
If Signaling System 7 support is activated (see MODE register), the
bit functions are defined as follows:
00 = Not valid
01 = Fill in signaling unit (FISU) detected
10 = Link status signaling unit (LSSU) detected
11 = Message signaling unit (MSU) detected
LA
Low Byte Address Compare - HDLC Channel 1
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared to two registers. (RAL1,
RAL2).
Data Sheet
0=
RAL2 has been recognized
1=
RAL1 has been recognized
309
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Byte Count Low - HDLC Channel 1 (Read)
RBCL
7
0
RBC7
RBC0
(66)
Together with RBCH, bits RBC(11:8), indicates the length of a
received frame (1 to 4095 bytes). Bits RBC(4:0) indicate the number
of valid bytes currently in RFIFO. These registers must be read by the
CPU following a RME interrupt.
Received Byte Count High - HDLC Channel 1 (Read)
Value after reset: 000xxxxx
7
0
RBCH
OV
OV
RBC11
RBC10
RBC9
RBC8
(67)
Counter Overflow - HDLC Channel 1
More than 4095 bytes received.
RBC(11:8)
Receive Byte Count - HDLC Channel 1 (most significant bits)
Together with RBCL, bits RBC(7:0) indicates the length of the
received frame.
Interrupt Status Register 0 (Read)
Value after reset: 00H
7
ISR0
RME
0
RFS
T8MS
RMB
CASC
CRC4
SA6SC
RPF
(68)
All bits are reset when ISR0 is read.
If bit GCR.VIS is set, interrupt statuses in ISR0 are flagged although they are masked by
register IMR0. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
RME
Receive Message End - HDLC Channel 1
One complete message of length less than 32 bytes, or the last part
of a frame at least 32 bytes long is stored in the receive FIFO,
including the status byte.
Data Sheet
310
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
The complete message length can be determined reading the RBCH,
RBCL registers, the number of bytes currently stored in RFIFO is
given by RBC(4:0). Additional information is available in the RSIS
register.
RFS
Receive Frame Start - HDLC Channel 1
This is an early receiver interrupt activated after the start of a valid
frame has been detected, i.e. after an address match (in operation
modes providing address recognition), or after the opening flag
(transparent mode 0) is detected, delayed by two bytes. After an RFS
interrupt, the contents of
• RAL1
• RSIS bits 3 to 1
are valid and can be read by the CPU.
T8MS
Receive Time Out 8 ms
Only active if multiframing is enabled.
The framer has found the double framing (basic framing)
FRS0.LFA = 0 and is searching for the multiframing. This interrupt is
set to indicate that no multiframing was found within a time window of
8 ms. In multiframe synchronous state this interrupt is not generated.
Refer also to floating multiframe alignment window.
RMB
Receive Multiframe Begin
This bit is set with the beginning of a received CRC multiframe related
to the internal receive line timing.
In CRC multiframe format FMR2.RFS1 = 1 or in doubleframe format
FMR2.RFS(1:0) = 01 this interrupt occurs every 2 ms. If
FMR2.RFS(1:0) = 00 this interrupt is generated every doubleframe
(512 bits).
CASC
Data Sheet
Received CAS Information Changed
This bit is set with the updating of a received CAS multiframe
information in the registers RS(16:1). If the last received CAS
information is different to the previous received one, this interrupt is
generated after update has been completed. This interrupt only
occurs only in TS0 and TS16 synchronous state. The registers
RS(16:1) should be read within the next 2 ms otherwise the contents
is lost.
311
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
CRC4
Receive CRC4 Error
0=
No CRC4 error occurs.
1=
The CRC4 check of the last received submultiframe failed.
Receive Sa6-Bit Status Changed
SA6SC
With every change of state of the received Sa6-bit combinations this
interrupt is set.
RPF
Receive Pool Full
32 bytes of a frame have arrived in the receive FIFO. The frame is not
yet completely received.
Interrupt Status Register 1 (Read)
7
ISR1
LLBSC
0
RDO
ALLS
XDU
XMB
SUEX
XLSC
XPR
(69)
All bits are reset when ISR1 is read.
If bit GCR.VIS is set, interrupt statuses in ISR1 are flagged although they are masked by
register IMR1. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
LLBSC
Line Loop-Back Status Change
Depending on bit LCR1.EPRM the source of this interrupt status
changed:
LCR1.EPRM = 0: This bit is set, if the LLB activate signal or the LLB
deactivate signal, respectively, is detected over a period of 25 ms with
a bit error rate less than 10-2.
The LLBSC bit is also set, if the current detection status is left, i.e., if
the bit error rate exceeds 10-2.
The actual detection status can be read from the RSP.LLBAD and
RSP.LLBDD, respectively.
PRBS Status Change
LCR1.EPRM = 1: With any change of state of the PRBS synchronizer
this bit is set. The current status of the PRBS synchronizer is
indicated in RSP.LLBAD.
Data Sheet
312
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RDO
Receive Data Overflow - HDLC Channel 1
This interrupt status indicates that the CPU did not respond fast
enough to an RPF or RME interrupt and that data in RFIFO has been
lost. Even when this interrupt status is generated, the frame continues
to be received when space in the RFIFO is available again.
Note: Whereas the bit RSIS.RDO in the frame status byte indicates
whether an overflow occurred when receiving the frame
currently accessed in the RFIFO, the ISR1.RDO interrupt
status is generated as soon as an overflow occurs and does
not necessarily pertain to the frame currently accessed by the
processor.
ALLS
All Sent - HDLC Channel 1
This bit is set if the last bit of the current frame has been sent
completely and XFIFO is empty. This bit is valid in HDLC mode only.
XDU
Transmit Data Underrun - HDLC Channel 1
Transmitted frame was terminated with an abort sequence because
no data was available for transmission in XFIFO and no XME was
issued.
Note: Transmitter and XFIFO are reset and deactivated if this
condition occurs. They are reactivated not before this interrupt
status register has been read. Thus, XDU should not be
masked by register IMR1.
XMB
Transmit Multiframe Begin
This bit is set every 2 ms with the beginning of a transmitted
multiframe related to the internal transmit line interface timing.
Just before setting this bit registers XS(16:1) are copied in the
transmit shift registers. The registers XS(16:1) are empty and has to
be updated otherwise the contents is retransmitted.
SUEX
Signaling Unit Error Threshold Exceeded - HDLC Channel 1
Masks the indication by interrupt that the selected error threshold for
SS7 signaling units has been exceeded.
0=
Signaling unit error count below selected threshold
1=
Signaling unit error count exceeded selected threshold
Note: SUEX is only valid, if SS7 mode is selected.
If SUEX is caused by an aborted/invalid frame, the interrupt will be
issued regularly until a valid frame is received (e.g. a FISU).
Data Sheet
313
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XLSC
Transmit Line Status Change
XLSC is set with the rising edge of the bit FRS1.XLO or with any
change of bit FRS1.XLS.
The actual status of the transmit line monitor can be read from the
FRS1.XLS and FRS1.XLO.
XPR
Transmit Pool Ready - HDLC Channel 1
A data block of up to 32 bytes can be written to the transmit FIFO.
XPR enables the fastest access to XFIFO. It has to be used for
transmission of long frames, back-to-back frames or frames with
shared flags.
Interrupt Status Register 2 (Read)
7
ISR2
FAR
0
LFA
MFAR
T400MS
AIS
LOS
RAR
RA
(6A)
All bits are reset when ISR2 is read.
If bit GCR.VIS is set, interrupt statuses in ISR2 are flagged although they are masked by
register IMR2. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
FAR
Frame Alignment Recovery
The framer has reached doubleframe synchronization. Set when bit
FRS0.LFA is reset. It is set also after alarm simulation is finished and
the receiver is still synchronous.
LFA
Loss of Frame Alignment
The framer has lost synchronization and bit FRS0.LFA is set. It is set
during alarm simulation.
MFAR
Multiframe Alignment Recovery
Set when the framer has found two CRC-multiframes at an interval of
n × 2 ms (n = 1, 2, 3, and so forth) without a framing error. At the
same time bit FRS0.LMFA is reset.
It is set also after alarm simulation is finished and the receiver is still
synchronous. Only active if CRC-multiframe format is selected.
Data Sheet
314
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
T400MS
Receive Time Out 400 ms
Only active if multiframing is enabled.
The framer has found the doubleframes (basic framing)
FRS0.LFA = 0 and is searching for the multiframing. This interrupt is
set to indicate that no multiframing was found within a time window of
400 ms after basic framing has been achieved. In multiframe
synchronous state this interrupt is not generated.
AIS
Alarm Indication Signal
This bit is set when an alarm indication signal is detected and bit
FRS0.AIS is set. It is set during alarm simulation.
If GCR.SCI is set high this interrupt status bit is set with every change
of state of FRS0.AIS.
LOS
Loss-of-Signal
This bit is set when a loss-of-signal alarm is detected in the received
bit stream and FRS0.LOS is set. It is set during alarm simulation.
If GCR.SCI is set high this interrupt status bit is set with every change
of state of FRS0.LOS.
RAR
Remote Alarm Recovery
Set if a remote alarm in TS0 is cleared and bit FRS0.RRA is reset. It
is set also after alarm simulation is finished and no remote alarm is
detected.
RA
Remote Alarm
Set if a remote alarm in TS0 is detected and bit FRS0.RRA is set. It
is set during alarm simulation.
Data Sheet
315
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Interrupt Status Register 3 (Read)
7
ISR3
ES
0
SEC
LMFA16
AIS16
RA16
RSN
RSP
(6B)
All bits are reset when ISR3 is read.
If bit GCR.VIS is set, interrupt statuses in ISR3 are flagged although they are masked by
register IMR3. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
ES
Errored Second
This bit is set if at least one enabled interrupt source by ESM is set
during the time interval of one second. Interrupt sources of ESM
register:
LFA = Loss of frame alignment detected (FRS0.LFA)
FER = Framing error received
CER = CRC error received
AIS = Alarm indication signal (FRS0.AIS)
LOS = Loss-of-signal (FRS0.LOS)
CVE = Code violation detected
SLIP = Receive Slip positive/negative detected
EBE = E-Bit error detected (RSP.RS13/15)
SEC
Second Timer
The internal one-second timer has expired. The timer is derived from
clock RCLK or external pin SEC/FSC.
LMFA16
Loss of Multiframe Alignment TS 16
Multiframe alignment of time slot 16 has been lost if two consecutive
multiframe pattern are not detected or if in 16 consecutive time slot 16
all bits are reset.
If register GCR.SCI is high this interrupt status bit is set with every
change of state of FRS1.TS16LFA.
AIS16
Alarm Indication Signal TS 16 Status Change
The alarm indication signal AIS in time slot 16 for the 64 kbit/s channel
associated signaling is detected or cleared. A change in bit
FRS1.TS16AIS sets this interrupt. (This bit is set if the incoming TS
16 signal contains less than 4 zeros in each of two consecutive TS16multiframe periods.)
Data Sheet
316
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RA16
Remote Alarm Time Slot 16 Status Change
A change in the remote alarm bit in CAS multiframe alignment word
is detected.
RSN
Receive Slip Negative
The frequency of the receive route clock is greater than the frequency
of the receive system interface working clock based on 2.048 MHz. A
frame is skipped. It is set during alarm simulation.
RSP
Receive Slip Positive
The frequency of the receive route clock is less than the frequency of
the receive system interface working clock based on 2.048 MHz. A
frame is repeated. It is set during alarm simulation.
Interrupt Status Register 4 (Read)
7
ISR4
XSP
0
XSN
RME2
RFS2
RDO2
ALLS2
XDU2
RPF2
(6C)
All bits are reset when ISR4 is read.
If bit GCR.VIS is set, interrupt statuses in ISR4 are flagged although they are masked by
register IMR4. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
XSP
Transmit Slip Positive
The frequency of the transmit clock is less than the frequency of the
transmit system interface working clock based on 2.048 MHz. A frame
is repeated. After a slip has performed writing of register XC1 is not
necessary.
XSN
Transmit Slip Negative
The frequency of the transmit clock is greater than the frequency of
the transmit system interface working clock based on 2.048 MHz. A
frame is skipped. After a slip has performed writing of register XC1 is
not necessary.
Data Sheet
317
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RME2
Receive Message End - HDLC Channel 2
One complete message of length less than 32 bytes, or the last part
of a frame at least 32 bytes long is stored in the receive FIFO2,
including the status byte.
The complete message length can be determined reading register
RBC2, the number of bytes currently stored in RFIFO2 is given by
RBC2(6:0). Additional information is available in register RSIS2.
RFS2
Receive Frame Start - HDLC Channel 2
This is an early receiver interrupt activated after the start of a valid
frame has been detected, i.e. after an address match (in operation
modes providing address recognition), or after the opening flag
(transparent mode 0) is detected, delayed by two bytes. After an
RFS2 interrupt, the contents of
• RAL1
• RSIS2 bits 3 to 1
are valid and can be read by the CPU.
RDO2
Receive Data Overflow - HDLC Channel 2
This interrupt status indicates that the CPU did not respond fast
enough to an RPF2 or RME2 interrupt and that data in RFIFO2 has
been lost. Even when this interrupt status is generated, the frame
continues to be received when space in the RFIFO2 is available
again.
Note: Whereas the bit RSIS2.RDO2 in the frame status byte
indicates whether an overflow occurred when receiving the
frame currently accessed in the RFIFO2, the ISR4.RDO2
interrupt status is generated as soon as an overflow occurs
and does not necessarily pertain to the frame currently
accessed by the processor.
ALLS2
All Sent - HDLC Channel 2
This bit is set if the last bit of the current frame has been sent
completely and XFIFO2 is empty. This bit is valid in HDLC mode only.
Data Sheet
318
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XDU2
Transmit Data Underrun - HDLC Channel 2
Transmitted frame was terminated with an abort sequence because
no data was available for transmission in XFIFO2 and no XME2 was
issued.
Note: Transmitter and XFIFO2 are reset and deactivated if this
condition occurs. They are reactivated not before this interrupt
status register has been read. Thus, XDU2 should not be
masked via register IMR4.
RPF2
Receive Pool Full - HDLC Channel 2
32 bytes of a frame have arrived in the receive FIFO2. The frame is
not yet completely received.
Interrupt Status Register 5 (Read)
7
ISR5
XPR2
0
XPR3
RME3
RFS3
RDO3
ALLS3
XDU3
RPF3
(6D)
All bits are reset when ISR5 is read.
If bit GCR.VIS is set, interrupt statuses in ISR5 are flagged although they are masked
via register IMR5. However, these masked interrupt statuses neither generate a signal
on INT, nor are visible in register GIS.
XPR2
Transmit Pool Ready - HDLC Channel 2
A data block of up to 32 bytes can be written to the transmit FIFO2.
XPR2 enables the fastest access to XFIFO2. It has to be used for
transmission of long frames, back-to-back frames or frames with
shared flags.
XPR3
Transmit Pool Ready - HDLC Channel 3
A data block of up to 32 bytes can be written to the transmit FIFO3.
XPR3 enables the fastest access to XFIFO3. It has to be used for
transmission of long frames, back-to-back frames or frames with
shared flags.
Data Sheet
319
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
RME3
Receive Message End - HDLC Channel 3
One complete message of length less than 32 bytes, or the last part
of a frame at least 32 bytes long is stored in the receive FIFO3,
including the status byte.
The complete message length can be determined reading register
RBC3, the number of bytes currently stored in RFIFO3 is given by
RBC3(6:0). Additional information is available in register RSIS3.
RFS3
Receive Frame Start - HDLC Channel 3
This is an early receiver interrupt activated after the start of a valid
frame has been detected, i.e. after an address match (in operation
modes providing address recognition), or after the opening flag
(transparent mode 0) is detected, delayed by two bytes. After an
RFS2 interrupt, the contents of
• RAL1
• RSIS3 bits 3 to 1
are valid and can be read by the CPU.
RDO3
Receive Data Overflow - HDLC Channel 3
This interrupt status indicates that the CPU did not respond fast
enough to an RPF3 or RME3 interrupt and that data in RFIFO3 has
been lost. Even when this interrupt status is generated, the frame
continues to be received when space in the RFIFO3 is available
again.
Note: Whereas the bit RSIS3.RDO3 in the frame status byte
indicates whether an overflow occurred when receiving the
frame currently accessed in the RFIFO3, the ISR5.RDO3
interrupt status is generated as soon as an overflow occurs
and does not necessarily pertain to the frame currently
accessed by the processor.
ALLS3
All Sent - HDLC Channel 3
This bit is set if the last bit of the current frame has been sent
completely and XFIFO3 is empty. This bit is valid in HDLC mode only.
Data Sheet
320
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XDU3
Transmit Data Underrun - HDLC Channel 3
Transmitted frame was terminated with an abort sequence because
no data was available for transmission in XFIFO3 and no XME3 was
issued.
Note: Transmitter and XFIFO3 are reset and deactivated if this
condition occurs. They are reactivated not before this interrupt
status register has been read. Thus, XDU3 should not be
masked via register IMR5.
RPF3
Receive Pool Full - HDLC Channel 3
32 bytes of a frame have arrived in the receive FIFO3. The frame is
not yet completely received.
Global Interrupt Status Register (Read)
Value after reset: 00H
7
GIS
0
ISR5
ISR4
ISR3
ISR2
ISR1
ISR0
(6E)
This status register points to pending interrupts sourced by ISR(5:0).
Data Sheet
321
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive CAS Register (Read)
Value after reset: not defined
Table 62
Receive CAS Registers (E1)
7
0
RS1
0
0
0
0
X
Y
X
X
(70)
RS2
A1
B1
C1
D1
A16
B16
C16
D16
(71)
RS3
A2
B2
C2
D2
A17
B17
C17
D17
(72)
RS4
A3
B3
C3
D3
A18
B18
C18
D18
(73)
RS5
A4
B4
C4
D4
A19
B19
C19
D19
(74)
RS6
A5
B5
C5
D5
A20
B20
C20
D20
(75)
RS7
A6
B6
C6
D6
A21
B21
C21
D21
(76)
RS8
A7
B7
C7
D7
A22
B22
C22
D22
(77)
RS9
A8
B8
C8
D8
A23
B23
C23
D23
(78)
RS10
A9
B9
C9
D9
A24
B24
C24
D24
(79)
RS11
A10
B10
C10
D10
A25
B25
C25
D25
(7A)
RS12
A11
B11
C11
D11
A26
B26
C26
D26
(7B)
RS13
A12
B12
C12
D12
A27
B27
C27
D27
(7C)
RS14
A13
B13
C13
D13
A28
B28
C28
D28
(7D)
RS15
A14
B14
C14
D14
A29
B29
C29
D29
(7E)
RS16
A15
B15
C15
D15
A30
B30
C30
D30
(7F)
Receive CAS Register (16:1)
Each register except RS1 contains the received CAS bits for two time slots. The received
CAS multiframe is compared to the previously received one. If the contents changed a
CAS multiframe changed interrupt (ISR0.CASC) is generated and informs the user that
a new multiframe has to be read within the next 2 ms. If requests for reading the RS(16:1)
register are ignored, the received data is lost. RS1 contains frame 0 of the CAS
multiframe. MSB is received first.
Additionally a receive signaling data change pointer indicates an update of register
RS(16:1). Refer also to register RSP(2:1).
Access to RS(16:1) registers is only valid if the serial receive signaling access on the
system highway is disabled.
Data Sheet
322
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Byte Count Register 2 (Read)
Value after reset: 00H
7
RBC2
OV2
OV2
0
RBC26
RBC25
RBC24
RBC23
RBC22
RBC21
RBC20
(90)
Counter Overflow - HDLC Channel 2
RBC2(6:0)
0=
Less than or equal to 128 bytes received
1=
More than 128 bytes received
Receive Byte Count - HDLC Channel 2
Indicates the length of a received frame.
Receive Byte Count Register 3 (Read)
Value after reset: 00H
7
RBC3
OV3
OV3
0
RBC36
RBC35
RBC34
RBC33
RBC32
RBC31
RBC30
(91)
Counter Overflow - HDLC Channel 3
RBC3(6:0)
0=
Less than or equal to 128 bytes received
1=
More than 128 bytes received
Receive Byte Count - HDLC Channel 3
Indicates the length of a received frame.
Signaling Status Register 2 (Read)
Value after reset: 00H
7
SIS2
XDOV2
XDOV2
0
XFW2
XREP2
RLI2
CEC2
(98)
Transmit Data Overflow - HDLC Channel 2
More than 32 bytes have been written to the XFIFO2.
This bit is reset
• by a transmitter reset command XRES or
• when all bytes in the accessible half of the XFIFO2 have been
moved in the inaccessible half.
Data Sheet
323
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XFW2
Transmit FIFO Write Enable - HDLC Channel 2
Data can be written to the XFIFO2.
XREP2
Transmission Repeat - HDLC Channel 2
Status indication of CMDR2.XREP2.
RLI2
Receive Line Inactive - HDLC Channel 2
Neither flags as interframe time fill nor frames are received via the
signaling time slot.
CEC2
Command Executing - HDLC Channel 2
0=
No command is currently executed, the CMDR3 register can be
written to.
1=
A command (written previously to CMDR3) is currently
executed, no further command can be temporarily written in
CMDR3 register.
Note: CEC2 will be active at most 2.5 periods of the current system
data rate.
Data Sheet
324
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive Signaling Status Register 2 (Read)
Value after reset: 00H
7
RSIS2
VFR2
0
RDO2
CRC162
RAB2
HA12
HA02
LA2
(99)
RSIS2 relates to the last received HDLC channel 2 frame; it is copied into RFIFO2 when
end-of-frame is recognized (last byte of each stored frame).
VFR2
Valid Frame - HDLC Channel 2
Determines whether a valid frame has been received.
1=
Valid
0=
Invalid
An invalid frame is either
– a frame which is not an integer number of 8 bits (n×8 bits) in length
(e.g. 25 bits), or
– a frame which is too short taking into account the operation mode
selected via MODE2 (MDS2(2:0)) and the selection of receive CRC
ON/OFF (CCR3.RCRC2) as follows:
• MDS2(2:0)=011 (16 bit Address),
RCRC2=0: 4 bytes; RCRC2=1: 3 or 4 bytes
• MDS2(2:0)=010 (8 bit Address),
RCRC2=0: 3 bytes; RCRC2=1: 2 or 3 bytes
Note: Shorter frames are not reported.
RDO2
Receive Data Overflow - HDLC Channel 2
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR4.RDO2/IMR4.RDO2).
CRC162
RAB2
CRC16 Compare/Check - HDLC Channel 2
0=
CRC check failed; received frame contains errors.
1=
CRC check o.k.; received frame is error-free.
Receive Message Aborted - HDLC Channel 2
This bit is set, if more than 5 contiguous 1-bits are detected.
Data Sheet
325
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
HA12, HA02
High Byte Address Compare - HDLC Channel 2
Significant only if 2-byte address mode is selected.
In operating modes which provide high byte address recognition, the
FALC® compares the high byte of a 2-byte address with the contents
of two individually programmable registers (RAH1, RAH2) and the
fixed values FEH and FCH (broadcast address).
Depending on the result of this comparison, the following bit
combinations are possible:
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R=0 (bit 1)
11 = RAH1 has been recognized C/R=1 (bit 1)
Note: If RAH1, RAH2 contain identical values, a match is indicated by
"10" or "11".
LA2
Low Byte Address Compare - HDLC Channel 2
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared with two registers. (RAL1,
RAL2).
0=
RAL2 has been recognized
1=
RAL1 has been recognized
Signaling Status Register 3 (Read)
Value after reset: 00H
7
SIS3
XDOV3
XDOV3
0
XFW3
XREP3
RLI3
CEC3
(9A)
Transmit Data Overflow - HDLC Channel 3
More than 32 bytes have been written to the XFIFO3.
This bit is reset
– by a transmitter reset command XRES or
– when all bytes in the accessible half of the XFIFO3 have been
moved in the inaccessible half.
XFW3
Transmit FIFO Write Enable - HDLC Channel 3
Data can be written to the XFIFO3.
Data Sheet
326
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
XREP3
Transmission Repeat - HDLC Channel 3
Status indication of CMDR3.XREP3.
RLI3
Receive Line Inactive - HDLC Channel 3
Neither flags as interframe time fill nor frames are received via the
signaling time slot.
CEC3
Command Executing - HDLC Channel 3
0=
No command is currently executed, the CMDR4 register can be
written to.
1=
A command (written previously to CMDR4) is currently
executed, no further command can be temporarily written in
CMDR4 register.
Note: CEC3 will be active up to 2.5 periods of the current system data
rate.
Receive Signaling Status Register 3 (Read)
Value after reset: 00H
7
RSIS3
VFR3
0
RDO3
CRC163
RAB3
HA13
HA03
LA3
(9B)
RSIS3 relates to the last received HDLC channel 3 frame; it is copied into RFIFO3 when
end-of-frame is recognized (last byte of each stored frame).
VFR3
Valid Frame - HDLC Channel 3
Determines whether a valid frame has been received.
1=
Valid
0=
Invalid
An invalid frame is either
– a frame which is not an integer number of 8 bits (n×8 bits) in length
(e.g. 25 bits), or
– a frame which is too short taking into account the operation mode
selected via MODE3 (MDS3(2:0)) and the selection of receive CRC
ON/OFF (CCR4.RCRC3) as follows:
• MDS3(2:0)=011 (16 bit Address),
RCRC3=0: 4 bytes; RCRC3=1: 3 or 4 bytes
• MDS3(2:0)=010 (8 bit Address),
RCRC3=0: 3 bytes; RCRC3=1: 2 or 3 bytes
Data Sheet
327
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Note: Shorter frames are not reported.
RDO3
Receive Data Overflow - HDLC Channel 3
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR5.RDO3/IMR5.RDO3).
CRC163
RAB3
CRC16 Compare/Check - HDLC Channel 3
0=
CRC check failed; received frame contains errors.
1=
CRC check o.k.; received frame is error-free.
Receive Message Aborted - HDLC Channel 3
This bit is set, if more than 5 contiguous 1-bits are detected.
HA13, HA03
High Byte Address Compare - HDLC Channel 3
Significant only if 2-byte address mode is selected.
In operating modes which provide high byte address recognition, the
FALC® compares the high byte of a 2-byte address with the contents
of two individually programmable registers (RAH1, RAH2) and the
fixed values FEH and FCH (broadcast address).
Depending on the result of this comparison, the following bit
combinations are possible:
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R=0 (bit 1)
11 = RAH1 has been recognized C/R=1 (bit 1)
Note: If RAH1, RAH2 contain identical values, a match is indicated by
"10" or "11".
LA3
Low Byte Address Compare - HDLC Channel 3
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared with two registers. (RAL1,
RAL2).
0=
1=
Data Sheet
RAL2 has been recognized
RAL1 has been recognized
328
2002-08-27
FALC56 V1.2
PEB 2256
E1 Registers
Receive FIFO 2 (Read)
Value after reset: 00H
7
0
RFIFO2
RF7
RF0
(9C)
RFIFO2
RF15
RF8
(9D)
RF(15:0)
Receive FIFO - HDLC Channel 2
The function is equivalent to RFIFO of HDLC channel 1.
Receive FIFO 3 (Read)
Value after reset: 00H
7
0
RFIFO3
RF7
RF0
(9E)
RFIFO3
RF15
RF8
(9F)
RF(15:0)
Receive FIFO - HDLC Channel 3
The function is equivalent to RFIFO of HDLC channel 1.
Identification Register (Read)
Value after reset: xxxxxx11
7
WID
x
0
x
x
x
x
x
1
1
(EC)
Additional version identification register.
Data Sheet
329
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
10
T1/J1 Registers
10.1
T1/J1 Control Register Addresses
Table 63
T1/J1 Control Register Address Arrangement
Address
Register
Type
Comment
Page
00
XFIFO
W
Transmit FIFO
334
01
XFIFO
W
Transmit FIFO
334
02
CMDR
W
Command Register
334
03
MODE
R/W
Mode Register
336
04
RAH1
R/W
Receive Address High 1
337
05
RAH2
R/W
Receive Address High 2
337
06
RAL1
R/W
Receive Address Low 1
337
07
RAL2
R/W
Receive Address Low 2
337
08
IPC
R/W
Interrupt Port Configuration
338
09
CCR1
R/W
Common Configuration Register 1 338
0A
CCR2
R/W
Common Configuration Register 2 341
0C
RTR1
R/W
Receive Time Slot Register 1
342
0D
RTR2
R/W
Receive Time Slot Register 2
342
0E
RTR3
R/W
Receive Time Slot Register 3
342
0F
RTR4
R/W
Receive Time Slot Register 4
342
10
TTR1
R/W
Transmit Time Slot Register 1
343
11
TTR2
R/W
Transmit Time Slot Register 2
343
12
TTR3
R/W
Transmit Time Slot Register 3
343
13
TTR4
R/W
Transmit Time Slot Register 4
343
14
IMR0
R/W
Interrupt Mask Register 0
344
15
IMR1
R/W
Interrupt Mask Register 1
344
16
IMR2
R/W
Interrupt Mask Register 2
344
17
IMR3
R/W
Interrupt Mask Register 3
344
18
IMR4
R/W
Interrupt Mask Register 4
344
19
IMR5
R/W
Interrupt Mask Register 5
344
1B
IERR
R/W
Single Bit Error Insertion Register 345
1C
FMR0
R/W
Framer Mode Register 0
Data Sheet
330
345
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Table 63
T1/J1 Control Register Address Arrangement (cont’d)
Address
Register
Type
Comment
Page
1D
FMR1
R/W
Framer Mode Register 1
347
1E
FMR2
R/W
Framer Mode Register 2
349
1F
LOOP
R/W
Channel Loop-Back
351
20
FMR4
R/W
Framer Mode Register 4
352
21
FMR5
R/W
Framer Mode Register 5
354
22
XC0
R/W
Transmit Control 0
355
23
XC1
R/W
Transmit Control 1
356
24
RC0
R/W
Receive Control 0
357
25
RC1
R/W
Receive Control 1
359
26
XPM0
R/W
Transmit Pulse Mask 0
361
27
XPM1
R/W
Transmit Pulse Mask 1
361
28
XPM2
R/W
Transmit Pulse Mask 2
361
2B
IDLE
R/W
Idle Channel Code
362
2C
XDL1
R/W
Transmit DL-Bit Register 1
362
2D
XDL2
R/W
Transmit DL-Bit Register 2
362
2E
XDL3
R/W
Transmit DL-Bit Register 3
362
2F
CCB1
R/W
Clear Channel Register 1
363
30
CCB2
R/W
Clear Channel Register 2
363
31
CCB3
R/W
Clear Channel Register 3
363
32
ICB1
R/W
Idle Channel Register 1
364
33
ICB2
R/W
Idle Channel Register 2
364
34
ICB3
R/W
Idle Channel Register 3
364
36
LIM0
R/W
Line Interface Mode 0
364
37
LIM1
R/W
Line Interface Mode 1
366
38
PCD
R/W
Pulse Count Detection
367
39
PCR
R/W
Pulse Count Recovery
368
3A
LIM2
R/W
Line Interface Register 2
369
3B
LCR1
R/W
Loop Code Register 1
370
3C
LCR2
R/W
Loop Code Register 2
372
3D
LCR3
R/W
Loop Code Register 3
372
Data Sheet
331
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Table 63
T1/J1 Control Register Address Arrangement (cont’d)
Address
Register
Type
Comment
Page
3E
SIC1
R/W
System Interface Control 1
373
3F
SIC2
R/W
System Interface Control 2
374
40
SIC3
R/W
System Interface Control 3
376
44
CMR1
R/W
Clock Mode Register 1
378
45
CMR2
R/W
Clock Mode Register 2
379
46
GCR
R/W
Global Configuration Register 1
381
47
ESM
R/W
Errored Second Mask
382
60
DEC
W
Disable Error Counter
382
70
XS1
W
Transmit Signaling Register 1
383
71
XS2
W
Transmit Signaling Register 2
383
72
XS3
W
Transmit Signaling Register 3
383
73
XS4
W
Transmit Signaling Register 4
383
74
XS5
W
Transmit Signaling Register 5
383
75
XS6
W
Transmit Signaling Register 6
383
76
XS7
W
Transmit Signaling Register 7
383
77
XS8
W
Transmit Signaling Register 8
383
78
XS9
W
Transmit Signaling Register 9
383
79
XS10
W
Transmit Signaling Register 10
383
7A
XS11
W
Transmit Signaling Register 11
383
7B
XS12
W
Transmit Signaling Register 12
383
80
PC1
R/W
Port Configuration 1
384
81
PC2
R/W
Port Configuration 2
384
82
PC3
R/W
Port Configuration 3
384
83
PC4
R/W
Port Configuration 4
384
84
PC5
R/W
Port Configuration 5
386
85
GPC1
R/W
Global Port Configuration 1
387
86
PC6
R/W
Port Configuration 6
388
x87
CMDR2
W
Command Register 2
389
88
CMDR3
W
Command Register 3
389
89
CMDR4
W
Command Register 4
390
Data Sheet
332
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Table 63
T1/J1 Control Register Address Arrangement (cont’d)
Address
Register
Type
Comment
Page
8B
CCR3
R/W
Common Control Register 3
391
8C
CCR4
R/W
Common Control Register 4
393
x8D
CCR5
R/W
Common Control Register 5
394
8E
MODE2
R/W
Mode Register 2
395
8F
MODE3
R/W
Mode Register 3
396
92
GCM1
R/W
Global Counter Mode 1
397
93
GCM2
R/W
Global Counter Mode 2
397
94
GCM3
R/W
Global Counter Mode 3
398
95
GCM4
R/W
Global Counter Mode 4
399
96
GCM5
R/W
Global Counter Mode 5
400
97
GCM6
R/W
Global Counter Mode 6
400
9C
XFIFO2
W
Transmit FIFO 2
402
9D
XFIFO2
W
Transmit FIFO 2
402
9E
XFIFO3
W
Transmit FIFO 3
402
9F
XFIFO3
W
Transmit FIFO 3
402
A0
TSEO
R/W
Time Slot Even/Odd Select
402
A1
TSBS1
R/W
Time Slot Bit Select 1
403
A2
TSBS2
R/W
Time Slot Bit Select 2
404
A3
TSBS3
R/W
Time Slot Bit Select 3
404
A4
TSS2
R/W
Time Slot Select 2
405
A5
TSS3
R/W
Time Slot Select 2
405
A8
TPC0
R/W
Test Pattern Control Register 0
406
After reset all control registers except the XFIFO and XS(12:1) are initialized to defined
values.
Unused bits have to be cleared.
Data Sheet
333
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
10.2
Detailed Description of T1/J1 Control Registers
Transmit FIFO - HDLC Channel 1 (Write)
7
0
XFIFO
XF7
XF0
(00)
XFIFO
XF15
XF8
(01)
Writing data to XFIFO of HDLC channel 1 can be done in 8-bit (byte) or 16-bit (word)
access. The LSB is transmitted first.
Up to 32 bytes/16 words of transmit data can be written to the XFIFO following an XPR
interrupt.
Command Register (Write)
Value after reset: 00H
7
CMDR
RMC
RMC
0
RRES
XREP
XRES
XHF
XTF
XME
SRES
(02)
Receive Message Complete - HDLC Channel 1
Confirmation from CPU to FALC56 that the current frame or data
block has been fetched following an RPF or RME interrupt, thus the
occupied space in the RFIFO can be released. If RMC is given while
RFIFO is already cleared, the next incoming data block is cleared
instantly, although interrupts are generated.
RRES
Receiver Reset
The receive line interface except the clock and data recovery unit
(DPLL), the receive framer, the one-second timer and the receive
signaling controller are reset. However the contents of the control
registers is not deleted.
XREP
Transmission Repeat - HDLC Channel 1
If XREP is set together with XTF (write 24H to CMDR), the FALC56
repeatedly transmits the contents of the XFIFO (1 to 32 bytes) without
HDLC framing fully transparently, i.e. without flag, CRC.
The cyclic transmission is stopped with an SRES command or by
resetting XREP.
Data Sheet
334
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Note: During cyclic transmission the XREP-bit has to be set with every
write operation to CMDR.
XRES
Transmitter Reset
The transmit framer and transmit line interface excluding the system
clock generator and the pulse shaper are reset. However the contents
of the control registers is not deleted.
XHF
Transmit HDLC Frame - HDLC Channel 1
After having written up to 32 bytes to the XFIFO, this command
initiates the transmission of a HDLC frame.
XTF
Transmit Transparent Frame - HDLC Channel 1
Initiates the transmission of a transparent frame without HDLC
framing.
XME
Transmit Message End - HDLC Channel 1
Indicates that the data block written last to the transmit FIFO
completes the current frame. The FALC56 can terminate the
transmission operation properly by appending the CRC and the
closing flag sequence to the data.
SRES
Signaling Transmitter Reset - HDLC Channel 1
The transmitter of the signaling controller is reset. XFIFO is cleared of
any data and an abort sequence (seven 1s) followed by interframe
time fill is transmitted. In response to XRES an XPR interrupt is
generated.
This command can be used by the CPU to abort a frame currently in
transmission.
Note: The maximum time between writing to the CMDR register and
the execution of the command takes 2.5 periods of the current
system data rate. Therefore, if the CPU operates with a very
high clock rate in comparison with the FALC56's clock, it is
recommended that bit SIS.CEC should be checked before
writing to the CMDR register to avoid any loss of commands.
Note: If SCLKX is used to clock the transmission path, commands to
the HDLC transmitter should only be sent while this clock is
available. If SCLKX is missing, the command register is
blocked after an HDLC command is given.
Data Sheet
335
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Mode Register (Read/Write)
Value after reset: 00H
7
MODE
MDS(2:0)
MDS2
0
MDS1
MDS0
BRAC
HRAC
DIV
(03)
Mode Select - HDLC Channel 1
The operating mode of the HDLC controller is selected.
000 = Reserved
001 = Signaling System 7 (SS7) support1)
010 = One-byte address comparison mode (RAL1, 2)
011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2)
100 = No address comparison
101 = One-byte address comparison mode (RAH1, 2)
110 = Reserved
111 = No HDLC framing mode 1
BRAC
BOM Receiver Active - HDLC Channel 1
Switches the BOM receiver to operational or inoperational state.
HRAC
0=
Receiver inactive
1=
Receiver active
Receiver Active - HDLC Channel 1
Switches the HDLC receiver to operational or inoperational state.
DIV
0=
Receiver inactive
1=
Receiver active
Data Inversion - HDLC Channel 1
Setting this bit inverts the internal generated HDLC channel 1 data
stream.
1)
0=
Normal operation, HDLC data stream not inverted
1=
HDLC data stream inverted
CCR2.RADD must be set, if SS7 mode is selected
Data Sheet
336
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Address Byte High Register 1 (Read/Write)
Value after reset: FDH
7
1
RAH1
0
0
(04)
In operating modes that provide high byte address recognition, the high byte of the
received address is compared to the individually programmable values in RAH1 and
RAH2. The address registers are used by all HDLC channels in common.
RAH1
Value of the First Individual High Address Byte
Bit 1 (C/R-bit) is excluded from address comparison.
Receive Address Byte High Register 2 (Read/Write)
Value after reset: FFH
7
0
RAH2
(05)
RAH2
Value of Second Individual High Address Byte
Receive Address Byte Low Register 1 (Read/Write)
Value after reset: FFH
7
0
RAL1
(06)
RAL1
Value of First Individual Low Address Byte
Receive Address Byte Low Register 2 (Read/Write)
Value after reset: FFH
7
0
RAL2
RAL2
Data Sheet
(07)
Value of the second individually programmable low address
byte.
337
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Interrupt Port Configuration (Read/Write)
Value after reset: 00H
7
0
IPC
SSYF
IC1
IC0
(08)
Unused bits have to be cleared.
SSYF
Select SYNC Frequency
Only applicable in master mode (LIM0.MAS = 1) and bit CMR2.DCF
is cleared.
IC0, IC1
0=
Reference clock on port SYNC is 1.544/2.048 MHz
(see LIM1.DCOC)
1=
Reference clock on port SYNC is 8 kHz
Interrupt Port Configuration
These bits define the function of the interrupt output stage (pin INT):
IC1
IC0
Function
X
0
1
0
1
1
Open drain output
Push/pull output, active low
Push/pull output, active high
Common Configuration Register 1 (Read/Write)
Value after reset: 00H
7
CCR1
BRM
EDLX
0
BRM
EDLX
EITS
ITF
XMFA
RFT1
RFT0
(09)
BOM Receive Mode - HDLC Channel 1
(significant in BOM mode only)
0=
10-byte packets
1=
Continuous reception
Enable DL-Bit Access through the Transmit FIFO - HDLC
Channel 1
A one in this bit position enables the internal DL-bit access through
the receive/transmit FIFO of the signaling controller. FMR1.EDL has
to be cleared.
Data Sheet
338
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
EITS
ITF
Enable Internal Time Slot 0 to 31 Signaling - HDLC Channel 1
0=
Internal signaling in time slots 0 to 31 defined by registers
RTR(4:1) or TTR(4:1) is disabled.
1=
Internal signaling in time slots 0 to 31 defined by registers
RTR(4:1) or TTR(4:1) is enabled.
Interframe Time Fill - HDLC Channel 1
Determines the idle (= no data to be sent) state of the transmit data
coming from the signaling controller.
XMFA
0=
Continuous logical 1 is output
1=
Continuous flag sequences are output (01111110 bit patterns)
Transmit Multiframe Aligned - HDLC Channel 1
Determines the synchronization between the framer and the
corresponding signaling controller.
0=
The contents of the XFIFO is transmitted without multiframe
alignment.
1=
The contents of the XFIFO is transmitted multiframe aligned.
If CCR1.EDLXis set, transmission of DL-bits is started in F72
format with frame 26. The first byte in XFIFO is transmitted in
the first time slot selected by TTR(4:1) and so on.
After receiving a complete multiframe in the time slot mode
(RTR(4:1)) an ISR0.RME interrupt is generated, if no HDLC or
BOM mode is enabled. In DL-bit access (CCR1.EDLX/
EITS = 10) XMFA is not valid.
Note: During the transmission of the XFIFO content, the SYPX or
XMFS interval time should not be changed, otherwise the
XFIFO data has to be retransmitted.
Data Sheet
339
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RFT(1:0)
RFIFO Threshold Level - HDLC Channel 1
The size of the accessible part of RFIFO can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT1
RFT0
Size of Accessible Part of RFIFO
0
0
1
1
0
1
0
1
32 bytes (reset value)
16 bytes
4 bytes
2 bytes
The value of RFT 1,0 can be changed dynamically
– If reception is not running or
– after the current data block has been read, but before the command
CMDR.RMC is issued (interrupt controlled data transfer).
Note: It is seen that changing the value of RFT1,0 is possible even
during the reception of one frame. The total length of the
received frame can be always read directly in RBCL, RBCH
after an RPF interrupt, except when the threshold is increased
during reception of that frame. The real length can then be
inferred by noting which bit positions in RBCL are reset by an
RMC command (see table below):
Data Sheet
RFT1
RFT0
Bit Positions in RBCL Reset by a
CMDR.RMC Command
0
0
1
1
0
1
0
1
RBC(4:0)
RBC(3:0)
RBC(1:0)
RBC0
340
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Common Configuration Register 2 (Read/Write)
Value after reset: 00H
7
0
CCR2
RADD
RBFE
RCRC
XCRC
(0A)
Unused bits have to be cleared.
RADD
Receive Address Pushed to RFIFO - HDLC Channel 1
If this bit is set, the received HDLC address information (1 or 2 bytes,
depending on the address mode selected by MODE.MDS0) is pushed
to RFIFO. This function is applicable in non-auto mode and
transparent mode 1. RADD must be set, if SS7 mode is selected.
RBFE
Receive BOM Filter Enable - HDLC Channel 1
Setting this bit the bit oriented message (BOM) receiver only accepts
BOM frames after detecting 7 out of 10 equal BOM pattern. The BOM
pattern is stored in the RFIFO adding a receive status byte marking a
BOM frame (RSIS.HFR) and an interrupt ISR0.RME is generated.
The current state of the BOM receiver is indicated in register SIS.IVB.
When the valid BOM pattern disappears an interrupt ISR0.BIV is
generated.
RCRC
Receive CRC on/off - HDLC Channel 1
Only applicable in non-auto mode.
If this bit is set, the received CRC checksum is written to RFIFO
(CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in
the received frame, is followed in the RFIFO by the status information
byte (contents of register RSIS). The received CRC checksum is
additionally checked for correctness. If non-auto mode is selected,
the limits for “valid frame” check are modified (refer to RSIS.VFR).
XCRC
Transmit CRC on/off - HDLC Channel 1
If this bit is set, the CRC checksum is not generated internally. It has
to be written as the last two bytes in the transmit FIFO (XFIFO). The
transmitted frame is closed automatically with a closing flag.
Note: The FALC56 does not check whether the length of the frame,
i.e., the number of bytes to be transmitted, makes sense or
not.
Data Sheet
341
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Time Slot Register 1 to 4 (Read/Write)
Value after reset: 00H, 00H, 00H, 00H
7
0
RTR1
TS0
TS1
TS2
TS3
TS4
TS5
TS6
TS7
(0C)
RTR2
TS8
TS9
TS10
TS11
TS12
TS13
TS14
TS15
(0D)
RTR3
TS16
TS17
TS18
TS19
TS20
TS21
TS22
TS23
(0E)
RTR4
TS24
TS25
TS26
TS27
TS28
TS29
TS30
TS31
(0F)
TS(31:0)
Time Slot Register
These bits define the received time slots on the system highway port
RDO to be extracted. Additionally these registers control the RSIGM
marker which can be forced high during the corresponding time slots
independently of bit CCR1.EITS.
A one in the RTR(4:1) bits samples the corresponding time slot in the
RFIFO of the signaling controller, if bit CCR1.EITS is set.
Assignments:
SIC2.SSC2 = 0: (32 time slots/frame)
TS0 → time slot 0,TS31 → time slot 31
SIC2.SSC2 = 1: (24 time slots/frame)
TS0 → time slot 0,TS23 → time slot 23
Data Sheet
0=
The corresponding time slot is not extracted and stored in the
RFIFO.
1=
The contents of the selected time slot is stored in the RFIFO.
Although the idle time slots can be selected. This function is
only active, if bits CCR1.EITS is set.
The corresponding time slot is forced high on pin RSIGM.
342
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Transmit Time Slot Register 1 to 4 (Read/Write)
Value after reset: 00H, 00H, 00H, 00H
7
0
TTR1
TS0
TS1
TS2
TS3
TS4
TS5
TS6
TS7
(10)
TTR2
TS8
TS9
TS10
TS11
TS12
TS13
TS14
TS15
(11)
TTR3
TS16
TS17
TS18
TS19
TS20
TS21
TS22
TS23
(12)
TTR4
TS24
TS25
TS26
TS27
TS28
TS29
TS30
TS31
(13)
TS(31:0)
Transmit Time Slot Register
These bits define the transmit time slots on the system highway to be
inserted. Additionally these registers control the XSIGM marker which
can be forced high during the corresponding time slots independently
of bit CCR1.EITS.
A one in the TTR(4:1) bits inserts the corresponding time slot sourced
by the XFIFO in the data received on pin XDI, if bit CCR1.EITS is set.
If SIC3.TTRF is set and CCR1.EDLX/EITS = 00, insertion of data
received on port XSIG is controlled by this registers.
Assignments:
SIC2.SSC2 = 0: (32 time slots/frame)
TS0 → time slot 0, TS31 → time slot 31
SIC2.SSC2 = 1: (24 time slots/frame)
TS0 → time slot 0, TS23 → time slot 23
Data Sheet
0=
The selected time slot is not inserted into the outgoing data
stream.
1=
The contents of the selected time slot is inserted into the
outgoing data stream from XFIFO. This function is only active,
if bits CCR1.EITS is set.
The corresponding time slot are forced high on marker pin
XSIGM.
343
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Interrupt Mask Registers
Value after reset: FFH, FFH, FFH, FFH,FFH
7
0
IMR0
RME
RFS
ISF
RMB
RSC
CRC6
PDEN
RPF
(14)
IMR1
CASE
RDO
ALLS
XDU
XMB
SUEX
XLSC
XPR
(15)
IMR2
FAR
LFA
MFAR
LMFA
AIS
LOS
RAR
RA
(16)
IMR3
ES
SEC
RSN
RSP
(17)
IMR4
XSP
XSN
RME2
RFS2
RDO2
ALLS2
XDU2
RPF2
(18)
IMR5
XPR2
XPR3
RME3
RFS3
RDO3
ALLS3
XDU3
RPF3
(19)
IMR(5:0)
LLBSC
Interrupt Mask Register
Each interrupt source can generate an interrupt signal on port INT
(characteristics of the output stage are defined by register IPC). A “1”
in a bit position of IMR(5:0) sets the mask active for the interrupt
status in ISR(5:0). Masked interrupt statuses neither generate a
signal on INT, nor are they visible in register GIS. Moreover, they are
–
not displayed in the Interrupt Status Register if bit GCR.VIS is
cleared
–
displayed in the Interrupt Status Register if bit GCR.VIS is set
After reset, all interrupts are disabled.
Data Sheet
344
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Single Bit Defect Insertion Register (Read/Write)
Value after reset: 00H
IERR
IFASE
IMFE
ICRCE
ICASE
IPE
IBV
(1B)
After setting the corresponding bit, the selected defect is inserted into the transmit data
stream at the next possible position. After defect insertion is completed, the bit is reset
automatically.
IFASE
Insert single FAS defect
IMFE
Insert single multiframe defect
ICRCE
Insert single CRC defect
ICASE
Insert single CAS defect
IPE
Insert single PRBS defect
IBV
Insert bipolar violation
Note: Except for CRC defects, CRC checksum calculation is done
after defect insertion.
Framer Mode Register 0 (Read/Write)
Value after reset: 00H
7
FMR0
XC(1:0)
XC1
0
XC0
RC1
RC0
FRS
SRAF
EXLS
SIM
(1C)
Transmit Code
Serial line code for the transmitter, independent of the receiver.
00 = NRZ (optical interface)
01 = CMI (1T2B+B8ZS), (optical interface)
10 = AMI coding with Zero Code Suppression (ZCS, B7-stuffing).
Disabling of the ZCS is done by activating the clear channel
mode by register CCB(3:1). (ternary or digital interface)
11 = B8ZS Code (ternary or digital dual-rail interface).
After changing XC(1:0), a transmitter software reset is required
(CMDR.XRES = 1).
RC(1:0)
Receive Code
Serial code receiver is independent to the transmitter.
Data Sheet
345
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
00 = NRZ (optical interface)
01 = CMI (1T2B+B8ZS), (optical interface)
10 = AMI coding with Zero Code Suppression (ZCS, B7-stuffing),
(ternary or digital dual-rail interface)
11 = B8ZS Code (ternary or digital dual-rail interface)
After changing RC(1:0), a receiver software reset is required
(CMDR.RRES = 1).
FRS
Force Resynchronization
A transition from low to high forces the frame aligner to execute a
resynchronization of the pulse frame. In the asynchronous state, a
new frame position is assumed at the next candidate if there is one.
Otherwise, a new frame search with the meaning of a general reset is
started. In the synchronous state this bit has the same meaning as bit
FMR0.EXLS except if FMR2.MCSP = 1.
SRAF
EXLS
Select Remote (Yellow) Alarm Format for F12 and ESF Format
0=
F12: bit2 = 0 in every channel. ESF: pattern
“1111 1111 0000 0000” in data link channel.
1=
F12: FS-bit of frame 12. ESF: bit2 = 0 in every channel
External Loss Of Frame
With a low to high transition a new frame search is started. This has
the meaning of a general reset of the internal frame alignment unit.
Synchronous state is reached only if there is one definite framing
candidate. In the case of multiple candidates, the setting of the bit
FMR0.FRS forces the receiver to lock onto the next available framing
position.
SIM
Alarm Simulation
Setting/resetting this bit initiates internal error simulation of: AIS (blue
alarm), loss-of-signal (red alarm), loss of frame alignment, remote
(yellow) alarm, slip, framing errors, CRC errors, code violations. The
error counters FEC, CVC, CEC, EBC are incremented.
The selection of simulated alarms is done by the error simulation
counter: FRS2.ESC(2:0) which is incremented with each setting of bit
FMR0.SIM. For complete checking of the alarm indications eight
simulation steps are necessary (FRS2.ESC(2:0) = 0 after a complete
simulation).
SIM has to be held stable at high or low level for at least one receive
clock period before changing it again.
Data Sheet
346
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Mode Register 1 (Read/Write)
Value after reset: 00H
7
FMR1
CTM
0
CTM
EDL
PMOD
CRC
ECM
SSD0
XAIS
(1D)
Channel Translation Mode
0=
Channel translation mode 0
1=
Channel translation mode 1
The different channel translation modes are described in Table 30 on
page 131.
EDL
Enable DL-Bit Access through Register XDL(3:1)
Only applicable in F4, F24 or F72 frame format.
PMOD
0=
Normal operation. The DL-bits are taken from system highway
or if enabled by CCR1.EDLX from the XFIFO of the signaling
controller.
1=
DL-bit register access. The DL-bit information are taken from
the registers XDL(3:1) and overwrite the DL-bits received on
the system highway (pin XDI) or from the internal XFIFO of the
signaling controller. However, transmission of the contents of
registers XDL(3:1) is disabled if transparent mode is enabled
(FMR4.TM).
PCM Mode
For E1 application this bit must be set low. Switching from E1 to T1 or
vice versa the device needs up to 20 µs to settle up to the internal
clocking.
CRC
0=
PCM 30 or E1 mode.
1=
PCM 24 or T1/J1 mode (see RC0.SJR for T1/J1 selection).
Enable CRC6
This bit is only significant when using the ESF format.
Data Sheet
0=
CRC6 check/generation disabled. For transmit direction, all
CRC bit positions are set.
1=
CRC6 check/generation enabled.
347
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
ECM
Error Counter Mode
The function of the error counters (FEC,CEC,CVC,EBC) is
determined by this bit.
SSD0
0=
Before reading an error counter the corresponding bit in the
Disable Error Counter register (DEC) has to be set. In 8 bit
access the low byte of the error counter should always be read
before the high byte. The error counters are reset with the rising
edge of the corresponding bits in the DEC register.
1=
Every second the error counter is latched and then
automatically reset. The latched error counter state should be
read within the next second. Reading the error counter during
updating should be avoided (do not access an error counter
within 1 µs after the one-second interrupt occurs).
Select System Date Rate 0
SIC1.SSD1, FMR1.SSD0 and SIC2.SSC2 define the data rate on the
system highway. Programming SSD1/SSD0 and corresponding data
rate is shown below.
SIC2.SSC2 = 0:
00 =
2.048 Mbit/s
01 =
4.096 Mbit/s
10 =
8.192 Mbit/s
11 =
16.384 Mbit/s
SIC2.SSC2 = 1:
XAIS
00 =
1.544 Mbit/s
01 =
3.088 Mbit/s
10 =
6.176 Mbit/s
11 =
12.352 Mbit/s
Transmit AIS Towards Remote End
Sends AIS (blue alarm) on ports XL1, XL2 towards the remote end.
If Local Loop Mode is enabled the transmitted data is looped back to
the system internal highway without any changes.
Data Sheet
348
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Mode Register 2 (Read/Write)
Value after reset: 00H
7
0
FMR2
MCSP
SSP
DAIS
SAIS
PLB
AXRA
EXZE
MCSP
Multiple Candidates Synchronization Procedure
SSP
Select Synchronization/Resynchronization Procedure
(1E)
Together with bit FMR2.SSP the synchronization mode of the receive
framer is defined:
MCSP/SSP:
00 = F12/F72 format:
Specified number of errors in both FT framing and FS framing lead to
loss of sync (FRS0.LFA is set). In the case of FS-bit framing errors,
bit FRS0.LMFA is set additionally. A complete new synchronization
procedure is initiated to regain pulseframe alignment and then
multiframe alignment.
F24:
normal operation: synchronization is achieved only on verification the
framing pattern.
01 = F12/F72:
Specified number of errors in FT framing has the same effect as
above. Specified number of errors in FS framing only initiates a new
search for multiframe alignment without influencing pulseframe
synchronous state (FRS0.LMFA is set).
F24:
Synchronous state is reached when three consecutive multiframe
pattern are correctly found independent of the occurrence of CRC6
errors.
10 = F12/F24:
A one enables a synchronization mode which is able to choose
multiple framing pattern candidates step by step. I.e. if in synchronous
state the CRC error counter indicates that the synchronization might
have been based on an alias framing pattern, setting of FMR0.FRS
leads to synchronization on the next candidate available. However,
only the previously assumed candidate is discarded in the internal
framing pattern memory. The latter procedure can be repeated until
the framer locks on the right pattern (no extensive CRC errors).
Therefore bit FMR1.CRC must be set.
Data Sheet
349
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
11 = F24:
Synchronization is achieved on verification the framing pattern and
the CRC6 bits. Synchronous state is reached when framing pattern
and CRC6 checksum are correctly found. For correct operation the
CRC check must be enabled by setting bit FMR1.CRC.
DAIS
SAIS
Disable AIS to System Interface
0=
AIS is automatically inserted into the data stream to RDO if
FALC56 is in asynchronous state.
1=
Automatic AIS insertion is disabled. Furthermore, AIS insertion
can be initiated by programming bit FMR2.SAIS.
Send AIS Towards System Interface
Sends AIS (blue alarm) on output RDO towards system interface.
This function is not influenced by bit FMR2.DAIS.
PLB
AXRA
Data Sheet
Payload Loop-Back
0=
Normal operation. Payload loop is disabled.
1=
The payload loop-back loops the data stream from the receiver
section back to transmitter section. Looped data is output on pin
RDO. Data received on port XDI, XSIG, SYPX and XMFS is
ignored. With FMR4.TM = 1 all 193 bits per frame are looped
back. If FMR4.TM = 0 the DL- or FS- or CRC-bits are generated
internally. AIS is sent immediately on port RDO by setting the
FMR2.SAIS bit. During payload loop is active the receive time
slot offset (registers RC(1:0)) should not be changed. It is
recommended to write the actual value of XC1 into this register
once again, because a write access to register XC1 sets the
read/write pointer of the transmit elastic buffer into its optimal
position to ensure a maximum wander compensation (the write
operation forces a slip).
Automatic Transmit Remote Alarm
0=
Normal operation
1=
The remote alarm (yellow alarm) bit is set automatically in the
outgoing data stream if the receiver is in asynchronous state
(FRS0.LFA bit is set). In synchronous state the remote alarm bit
is reset.
350
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
EXZE
Excessive Zeros Detection Enable
Selects error detection mode in the bipolar receive bit stream.
0=
Only bipolar violations are detected.
1=
Bipolar violations and zero strings of 8 or more contiguous
zeros in B8ZS code or more than 15 contiguous zeros in AMI
code are detected additionally and counted in the code
violation counter CVC.
LOOP (Read/Write)
Value after reset: 00H
7
LOOP
RTM
0
RTM
ECLB
CLA4
CLA3
CLA2
CLA1
CLA0
(1F)
Receive Transparent Mode
Setting this bit disconnects control of the internal elastic store from the
receiver. The elastic store is now in a “free running” mode without any
possibility to actualize the time slot assignment to a new frame
position in case of resynchronization of the receiver. This function can
be used together with the “disable AIS to system interface” feature
(FMR2.DAIS) to realize undisturbed transparent reception.
This bit should be enabled in case of unframed data reception mode.
ECLB
Enable Channel Loop-Back
0=
Disables the channel loop-back.
1=
Enables the channel loop-back selected by this register.
Note: CAS-BR must be switched off (FMR5.EIBR = 0) while channel
loop back is enabled.
CLA(4:0)
Channel Address For Loop-Back
CLA = 1 to 24 selects the channel.
During loop-back, the contents of the associated outgoing channel on
ports XL1/XDOP/XOID and XL2/XDON is equal to the idle channel
code programmed in register IDLE.
Data Sheet
351
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Mode Register 4 (Read/Write)
Value after reset: 00H
7
FMR4
AIS3
AIS3
0
TM
XRA
SSC1
SSC0
AUTO
FM1
FM0
(20)
Select AIS Condition
0=
AIS (blue alarm) is indicated (FRS0.AIS) when two or less zeros
in the received bit stream are detected in a time interval of 12
frames (F4, F12, F72) or 24 frames (ESF).
1=
AIS (blue alarm) detection is only enabled when FALC56 is in
asynchronous state. The alarm is indicated (FRS0.AIS) when
– three or less zeros within a time interval of 12 frames (F4,
F12, F72), or
– five or less zeros within a time interval of 24 frames (ESF)
are detected in the received bit stream.
TM
Transparent Mode
Setting this bit enables the transparent mode:
In transmit direction bit 8 of every FS/DL time slot from the system
internal highway (XDI) is inserted in the F-bit position of the outgoing
frame. Internal framing generation, insertion of CRC and DL data is
disabled.
XRA
Transmit Remote Alarm (Yellow Alarm)
If high, remote alarm is sent on the PCM route. Clearing the bit
removes the remote alarm pattern. Remote alarm indication depends
on the multiframe structure as follows:
F4: Bit2 = 0 in every speech channel
F12: – FMR0.SRAF = 0: bit2 = 0 in every speech channel
– FMR0.SRAF = 1: FS-bit of frame 12 is forced to “1”
ESF: – FMR0.SRAF = 0: pattern
“1111111100000000 11111111000”
in data link channel
– FMR0.SRAF = 1: bit2 = 0 in every speech channel
F72: Bit2 = 0 in every speech channel
Data Sheet
352
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
SSC(1:0)
Select Sync Conditions
Loss of Frame Alignment (FRS0.LFA or opt. FRS0.LMFA) is declared
if:
00 = 2 out of 4 framing bits
01 = 2 out of 5 framing bits
10 = 2 out of 6 framing bits in F4/12/72 format
10 = 2 out of 6 framing bits per multiframe period in ESF format
11 = 4 consecutive multiframe pattern in ESF format
are incorrect. It depends on the selected multiframe format and
optionally on bit FMR2.SSP which framing bits are observed:
F4: FT-bits → FRS0.LFA
F12, F72:SSP = 0:
FT-bits→ FRS0.LFA
FS-bits → FRS0.LFA and FRS0.LMFA
F12, F72:SSP = 1:
FT → FRS0.LFA
FS → FRS0.LMFA
ESF: ESF framing bits → FRS0.LFA
AUTO
FM(1:0)
Enable Auto Resynchronization
0=
The receiver does not re synchronize automatically. Starting a
new synchronization procedure is possible by the bits
FMR0.EXLS or FMR0.FRS.
1=
Auto-resynchronization is enabled.
Select Frame Mode
FM = 0: 12-frame multiframe format (F12, D3/4)
FM = 1: 4-frame multiframe format (F4)
FM = 2: 24-frame multiframe format (ESF)
FM = 3: 72-frame multiframe format (F72, remote switch mode)
Data Sheet
353
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Mode Register 5 (Read/Write)
Value after reset: 00H
7
FMR5
EIBR
XLD
XLU
XTM
0
EIBR
XLD
XLU
XTM
SSC2
(21)
Enable Internal Bit Robbing Access
0=
Normal operation.
1=
A one in this bit position causes the transmitter to send the bit
robbing signaling information stored in the XS(12:1) (ESF, F12,
72) registers or serial CAS in the corresponding time slots.
Transmit Line Loop-Back (LLB) Down Code
0=
Normal operation.
1=
A one in this bit position causes the transmitter to replace
normal transmit data with the LLB down (deactivate) Code
continuously until this bit is reset. The LLB down code is
overwritten by the framing/DL/CRC bits optionally.
Transmit LLB Up Code
0=
Normal operation.
1=
A one in this bit position causes the transmitter to replace
normal transmit data with the LLB up (activate) code
continuously until this bit is reset. The LLB up code is optionally
overwritten by the framing/DL/CRC bits. For proper operation
bit FMR5.XLD must be cleared.
Transmit Transparent Mode
0 =Ports SYPX/XMFS define the frame/multiframe begin on the
transmit system highway. The transmitter is usually
synchronized on this externally sourced frame boundary and
generates the FS/DL-bits according to this framing. Any change
of the transmit time slot assignment subsequently produces a
change of the FS/DL-bit positions.
1=
Data Sheet
Disconnects the control of the transmit system interface from
the transmitter. The transmitter is now in a free running mode
without any possibility to actualize the multiframe position. The
framing (FS/DL-bits) generated by the transmitter are not
“disturbed“ (in case of changing the transmit time slot
assignment) by the transmit system highway unless register
XC1 is written. This bit should be set if loop-timed application is
354
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
selected. For proper operation the transmit elastic buffer (2
frames, SIC1.XBS(1:0) = 10) has to be enabled.
SSC2
Select Sync Conditions
Only valid in ESF framing format.
Loss of Frame Alignment FRS0.LFA is declared if more than 320
CRC6 errors per second interval are detected.
Transmit Control 0 (Read/Write)
Value after reset: 00H
7
XC0
BRM
BRM
0
MFBS
BRFO
XCO10
XCO9
XCO8
(22)
Enable Bit Robbing Marker
A one in this bit marks the robbed bit positions on the system highway.
RSIGM marks the receive and XSIGM marks the transmit robbed bits.
MFBS
Enable pure Multiframe Begin Signals
Only valid if ESF or F72 format is selected.
BRFO
0=
RMFB marks the beginning of every received superframe.
Additional pulses are provided every 12 frames when using
ESF/F24 or F72 format.
1=
RMFB marks the beginning of every received multiframe.
Bit Robbing Force One
Setting this bit forces the robbed bits high transmitted on port RDO.
The received signaling data stream for the signaling controller is not
influenced by this bit.
XCO(10:8)
Transmit Offset
Initial value loaded into the transmit bit counter at the trigger edge of
SCLKX when the synchronous pulse on port SYPX or XMFS is active
Refer to register XC1.
Data Sheet
355
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Transmit Control 1 (Read/Write)
Value after reset: 9CH
XC1
7
0
XCO7
XCO0
(23)
A write access to this address resets the transmit elastic buffer to its
basic starting position. Therefore, updating the value should only be
done when the FALC56 is initialized or when the buffer should be
centered. As a consequence a transmit slip will occur.
XCO(7:0)
Transmit Offset
Initial value loaded into the transmit bit counter at the trigger edge of
SCLKX when the synchronous pulse on port SYPX/XMFS is active.
Calculation of delay time T (SCLKX cycles) depends on the value X
of the transmit offset register XC(1:0):
system clocking rate: modulo 2.048 MHz (SIC2.SSC2 = 0)
0 ≤ T ≤ 4: X = 4 - T
5 ≤ T ≤ maximum delay:X = 256 × SC/SD - T + 4)
with maximum delay = (256 × SC/SD) -1
with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2
with SD = 2.048 Mbit/s (system clocking n × 2.048 MHz)
or
system clocking rate: modulo 1.544 MHz (SIC2.SSC2 = 1)
0 ≤ T ≤ 4: X = 3 - T + 7 × SC/BF
5 ≤ T ≤ maximum delay:X = 200 × SC/BF - T + 3
with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2
SD = 1.544 Mbit/s (system clocking n × 1.544 MHz)
with BF = basic frequency = 1.544 MHz
T = Time between the active edge of SCLKX after SYPX pulse begin
and beginning of the next frame (F-bit, channel phase 0), measured
in number of SCLKX clock intervals; maximum delay:
Tmax = (200 × SC/BF) - (7 × SC/BF) - 1
See page 178 for further description.
Data Sheet
356
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Control 0 (Read/Write)
Value after reset: 00H
7
RC0
SJR
RRAM
SJR
0
RRAM
CRCI
XCRCI
RDIS
RCO10
RCO9
RCO8
(24)
Select Japanese ITU-T Requirements
0=
T1: Alarm handling is done according ITU-T G. 704+706
1=
J1: Alarm handling is done according ITU-T JG. 704+706
Receive Remote Alarm Mode
The conditions for remote (yellow) alarm (FRS0.RRA) detection can
be selected by this bit to allow detection even in the presence of a bit
error rate of up to 10-3:
RRAM = 0
Detection
F4: Bit2 = 0 in every speech channel per frame.
F12: – FMR0.SRAF = 0: bit2 = 0 in every speech channel per frame.
– FMR0.SRAF = 1: S-bit of frame 12 is forced to “1”
ESF: – FMR0.SRAF = 0: pattern “1111 1111 0000 0000” in data
link channel
– FMR0.SRAF = 1: bit2 = 0 in every speech channel
F72: Bit2 = 0 in every speech channel per frame.
Release: The alarm is reset when above conditions are no longer
detected.
RRAM = 1 (bit error rate 10-3)
Detection
F4: Bit2 = 0 in 255 consecutive speech channels.
F12: – FMR0.SRAF = 0: bit 2 = 0 in 255 consecutive speech
channels.
– FMR0.SRAF = 1: S-bit of frame 12 is forced to “1”
ESF: – FMR0.SRAF = 0: pattern “1111 1111 0000 0000” in data
link channel
– FMR0.SRAF = 1: bit 2 = 0 in 255 consecutive speech
channels
F72: Bit 2 = 0 in 255 consecutive speech channels.
Data Sheet
357
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Release
Depending on the selected multiframe format the alarm is reset when
FALC56 does not detect
– the “bit 2 = 0" condition for three consecutive pulse frames
(all formats if selected),
– the "FS-bit" condition for three consecutive multiframes (F12),
– the "DL pattern" for three times in a row (ESF).
CRCI
Automatic CRC6 Bit Inversion
If set, all CRC bits of one outgoing extended multiframe are inverted
in case a CRC error is flagged for the previous received multiframe.
This function is logically ored with RC0.XCRCI.
XCRCI
Transmit CRC6 Bit Inversion
If set, the CRC bits in the outgoing data stream are inverted before
transmission. This function is logically ored with RC0.CRCI.
RDIS
Receive Data Input Sense
Digital interface, dual-rail:
0=
Inputs RDIP/RDIN are active low
1=
Inputs RDIP/RDIN are active high
Digital Interface, CMI:
RCO(10:8)
0=
Input ROID is active high
1=
Input ROID is active low
Receive Offset/Receive Frame Marker Offset
Depending on the RP(A to D) pin function different offsets can be
programmed. The SYPR and the RFM pin function cannot be
selected in parallel.
Receive Offset (PC(4:1).RPC(2:0) = 000)
Initial value loaded into the receive bit counter at the trigger edge of
SCLKR when the synchronous pulse on port SYPR is active.
Calculation of delay time T (SCLKR cycles) depends on the value X
of the receive offset register RC(1:0). Refer to register RC1.
Data Sheet
358
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Control 1 (Read/Write)
Value after reset: 9CH
7
RC1
RCO(7:0)
RCO7
0
RCO5
RCO0
(25)
Receive Offset/Receive Frame Marker Offset
Depending on the RP(A to D) pin function different offsets can be
programmed. The SYPR and the RFM pin function cannot be
selected in parallel.
Receive Offset (PC(4:1).RPC(2:0) = 000)
Initial value loaded into the receive bit counter at the trigger edge of
SCLKR when the synchronous pulse on port SYPR is active.
Calculation of delay time T (SCLKR cycles) depends on the value X
of the receive offset register RC(1:0):
system clocking rate: modulo 2.048 MHz (SIC2.SSC2 = 0)
0 ≤ T ≤ 4:X = 4 - T
5 ≤ T ≤ maximum delay:X = 2052 - T
with maximum delay = (256×SC/SD) -1
with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2
with SD = system data rate
or
system clocking rate: modulo 1.544 MHz (SIC2.SSC2 = 1)
0 ≤ T ≤ 4:X = 4 - T + (7 × SC/SD)
5 ≤ T ≤ maximum delay :X = (200 × SC/SD) + 4 - T
with maximum delay = 193×SC/SD - 1
with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2
with SD = system data rate
Delay time T = time between beginning of time slot 0 at RDO and the
initial edge of SCLKR after SYPR goes active.
See page 168 for further description.
Data Sheet
359
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Frame Marker Offset (PC(4:1).RPC(2:0) = 001B)
Offset programming of the receive frame marker which is output on
multifunction port RFM. The receive frame marker can be activated
during any bit position of the entire frame and depends on the
selected system clock rate.
Calculation of the value X of the receive offset register RC(1:0)
depends on the bit position which should be marked at marker
position MP:
system clocking rate: modulo 2.048 MHz (SIC2.SSC2 = 0)
0 ≤ MP ≤ 2045:X = MP + 2
2046 ≤ MP ≤ 2047:X = MP - 2046)
e.g: 2.048 MHz: MP = 0 to 255; 4.096 MHz: MP = 0 to 511,
8.192 MHz: MP = 0 to 1023, 16.384 MHz: MP = 0 to 2047
system clocking rate: modulo 1.544 MHz (SIC2.SSC2 = 1)
0 ≤ MP ≤ 193 × (SC/SD) - 3:X = MP + 2 + 7 × SC/SD
193 × (SC/SD) -2 ≤ MP ≤ maximum delay:X = MP + 2 - 186 × SC/
SD
with maximum delay = 193×SC/SD - 1
with SC = system clock defined by SIC1.SSC(1:0)+SIC2.SSC2
with SD = system data rate
Data Sheet
360
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Transmit Pulse-Mask Registers (Read/Write)
Value after reset: 7BH, 03H, 40H
7
0
XPM0
XP12
XP11
XP10
XP04
XP03
XP02
XP01
XP00
(26)
XPM1
XP30
XP24
XP23
XP22
XP21
XP20
XP14
XP13
(27)
XPM2
0
XLT
DAXLT
XP34
XP33
XP32
XP31
(28)
The transmit pulse shape which is defined in ANSI T1.102 is output on pins XL1 and XL2.
The level of the pulse shape can be programmed by registers XPM(2:0) to create a
custom waveform. In order to get an optimized pulse shape for the external transformers
each pulse shape is internally divided into four sub pulse shapes. In each sub pulse
shape a programmed 5 bit value defines the level of the analog voltage on pins XL1/2.
Together four 5 bit values have to be programmed to form one complete transmit pulse
shape.The four 5 bit values are sent in the following sequence:
XP04 to 00:
XP14 to 10:
XP24 to 20:
XP34 to 30:
First pulse shape level
Second pulse shape level
Third pulse shape level
Fourth pulse shape level
Changing the LSB of each subpulse in registers XPM(2:0) changes the amplitude of the
differential voltage on XL1/2 by approximately 80 mV.
The XPM values in the following table are based on simulations. They are valid for the
following external circuitry: transformer ratio 1:2.4, cable PULB 22AWG (100Ω), serial
resistors 2Ω. Adjustment of these coefficients can be necessary for other external
conditions.
Table 64
Range in
m
Pulse Shaper Programming (T1/J1)
Range in
ft.
XPM0
XPM1
XPM2
XP04- XP14XP00 XP10
hexadecimal
XP24XP20
XP34XP30
decimal
0 to 40
0 to 133
D7
22
1
23
22
8
2
40 to 81
133 to 266 FA
26
1
26
23
9
2
81 to 122
266 to 399 3D
37
1
29
25
13
2
122 to 162 399 to 533 5F
3F
1
31
26
15
2
162 to 200 533 to 655 3F
CB
1
31
25
18
3
Data Sheet
361
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XLT
Transmit Line Tristate
DAXLT
0=
Normal operation
1=
Transmit line XL1/XL2 or XDOP/XDON are switched into highimpedance state. If this bit is set the transmit line monitor status
information is frozen (default value after hardware reset).
Disable Automatic Tristating of XL1/2
0=
Normal operation. If a short is detected on pins XL1/2 the
transmit line monitor sets the XL1/2 outputs into a highimpedance state.
1=
If a short is detected on pins XL1/2, the automatic setting of
these pins into a high-impedance state (by the XL-monitor) is
disabled.
Idle Channel Code Register (Read/Write)
Value after reset: 00H
IDLE
7
0
IDL7
IDL0
IDL(7:0)
(2B)
Idle Channel Code
If channel loop-back is enabled by programming the register
LOOP.ECLB = 1, the contents of the assigned outgoing channel on
ports XL1/XL2 or XDOP/XDON is set equal to the idle channel code
selected by this register.
Additionally, the specified pattern overwrites the contents of all
channels of the outgoing PCM frame selected by the idle channel
registers ICB(3:1). IDL7 is transmitted first.
Transmit DL-Bit Register 1-3 (Read/Write)
Value after reset: 00H, 00H, 00H
7
0
XDL1
XDL17
XDL16
XDL15
XDL14
XDL13
XDL12
XDL11
XDL10
(2C)
XDL2
XDL27
XDL26
XDL25
XDL24
XDL23
XDL22
XDL21
XDL20
(2D)
XDL3
XDL37
XDL36
XDL35
XDL34
XDL33
XDL32
XDL31
XDL30
(2E)
Data Sheet
362
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XDL(3:1)
Transmit FS/DL-Bit Data
The DL-bit register access is enabled by setting bits FMR1.EDL = 1.
With the transmit multiframe begin an interrupt ISR1.XMB is
generated and the contents of these registers XDL(3:1) is copied into
a shadow register. The contents is subsequently sent out in the data
stream of the next outgoing multiframe if no transparent mode is
enabled. XDL10 is sent out first.
In F4 frame format only XDL10+XDL11 are transmitted. In F24 frame
format XDL10 to 23 are shifted out. In F72 frame format XDL10 to 37
are transmitted.
The transmit multiframe begin interrupt (XMB) requests that these
registers should be serviced. If requests for new information are
ignored, the current contents is repeated.
Clear Channel Register (Read/Write)
Value after reset: 00H, 00H, 00H
7
0
CCB1
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
(2F)
CCB2
CH9
CH10
CH11
CH12
CH13
CH14
CH15
CH16
(30)
CCB3
CH17
CH18
CH19
CH20
CH21
CH22
CH23
CH24
(31)
CH(24:1)
Data Sheet
Channel Selection Bits
0=
Normal operation. Bit robbing information and zero code
suppression (ZCS, B7 stuffing) can change contents of the
selected speech/data channel if assigned modes are enabled
by bits FMR5.EIBR and FMR0.XC(1:0).
1=
Clear channel mode. Contents of selected speech/data
channel are not overwritten by internal or external bit robbing
and ZCS information. Transmission of channel assigned
signaling and control of pulse-density is applied by the user.
363
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Idle Channel Register (Read/Write)
Value after reset: 00H, 00H, 00H, 00H
7
0
ICB1
IC1
IC2
IC3
IC4
IC5
IC6
IC7
IC8
(32)
ICB2
IC9
IC10
IC11
IC12
IC13
IC14
IC15
IC16
(33)
ICB3
IC17
IC18
IC19
IC20
IC21
IC22
IC23
IC24
(34)
IC(24:1)
Idle Channel Selection Bits
These bits define the channels (time slots) of the outgoing PCM frame
to be altered.
0=
Normal operation.
1=
Idle channel mode. The contents of the selected channel is
overwritten by the idle channel code defined by register IDLE.
Line Interface Mode 0 (Read/Write)
Value after reset: 00H
7
LIM0
XFB
XFB
0
XDOS
EQON
RLM
LL
MAS
(36)
Transmit Full Bauded Mode
Only applicable for dual-rail mode (bit LIM1.DRS = 1).
0=
Output signals XDOP/XDON are half bauded (normal
operation).
1=
Output signals XDOP/XDON are full bauded.
Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to
be cleared.
Data Sheet
364
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XDOS
Transmit Data Out Sense
0=
Output signals XDOP/XDON are active low. Output XOID is
active high (normal operation).
1=
Output signals XDOP/XDON are active high. Output XOID is
active low.
Note: If CMI coding is selected (FMR0.XC(1:0) = 01) this bit has to
be cleared.
The transmit frame marker XFM is independent of this bit.
EQON
RLM
LL
MAS
Data Sheet
Receive Equalizer On
0=
-10 dB receiver: short-haul mode
1=
-36 dB receiver: long-haul mode
Receive Line Monitoring
0=
Normal receiver mode
1=
Receiver mode for receive line monitoring;
the receiver sensitivity is increased to detect resistively
attenuated signals of -20 dB (short-haul mode only)
Local Loop
0=
Normal operation
1=
Local loop active. The local loop-back mode disconnects the
receive lines RL1/RL2 or RDIP/RDIN from the receiver. Instead
of the signals coming from the line the data provided by system
interface is routed through the analog receiver back to the
system interface. The unipolar bit stream is transmitted
undisturbedly on the line. Receiver and transmitter coding must
be identical. Operates in analog and digital line interface mode.
In analog line interface mode data is transferred through the
complete analog receiver.
Master Mode
0=
Slave mode
1=
Master mode on. Setting this bit the DCO-R circuitry is
frequency synchronized to the clock (1.544, 2.048 MHz or
8 kHz, see IPC.SSYF, LIM1.DCOC) supplied by SYNC. If this
pin is connected to VSS or VDD (or left open and pulled up to VDD
internally) the DCO-R circuitry is centered and no receive jitter
attenuation is performed (only if 1.544 or 2.048 MHz clock is
selected by resetting bit IPC.SSYF). The generated clocks are
stable.
365
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Line Interface Mode 1 (Read/Write)
Value after reset: 00H
7
LIM1
CLOS
RIL(2:0)
CLOS
0
RIL2
RIL1
RIL0
DCOC
JATT
RL
DRS
(37)
Clear data in case of LOS
0=
Normal receiver mode, receive data stream is transferred
normally in long-haul mode
1=
In long-haul mode received data is cleared (driven low), as
soon as LOS is detected
Receive Input Threshold
Only valid if analog line interface is selected (LIM1.DRS = 0).
“No signal” is declared if the voltage between pins RL1 and RL2 drops
below the limits programmed by bits RIL(2:0) and the received data
stream has no transition for a period defined in the PCD register.
The threshold where “no signal” is declared is programmable by the
RIL(2:0) bits depending on bit LIM0.EQON.
Note: LIM1.RIL(2:0) must be programmed before LIM0.EQON = 1 is
set.
See the DC characteristics for detail.
DCOC
DCO-R Control
0=
1.544 MHz reference clock for the DCO-R circuitry provided on
pin SYNC.
1=
2.048 MHz reference clock for the DCO-R circuitry provided on
pin SYNC.
Note: If IPC.SSYF = 1, external reference clock frequency is 8.0 kHz
independent of DCOC.
Data Sheet
366
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
JATT, RL
Remote Loop Transmit Jitter Attenuator
00 = Normal operation. The remote loop transmit jitter attenuator is
disabled. Transmit data bypasses the remote loop jitter
attenuator buffer.
01 = Remote Loop active without transmit jitter attenuator enabled.
Transmit data bypasses the remote loop jitter attenuator buffer.
10 = not assigned
11 = Remote Loop and remote loop jitter attenuator active. Received
data from pins RL1/2 or RDIP/N or ROID is sent "jitter-free" on
ports XL1/2 or XDOP/N or XOID. The de-jittered clock is
generated by the DCO-X circuitry.
Note: JATT is only used to define the jitter attenuation during remote
loop operation. Jitter attenuation during normal operation is
not affected.
DRS
Dual-Rail Select
0=
The ternary interface is selected. Multifunction ports RL1/2 and
XL1/2 become analog in/outputs.
1=
The digital dual-rail interface is selected. Received data is
latched on multifunction ports RDIP/RDIN while transmit data is
output on pins XDOP/XDON.
Pulse Count Detection Register (Read/Write)
Value after reset: 00H
PCD
PCD(7:0)
7
0
PCD7
PCD0
(38)
Pulse Count Detection
A LOS alarm (red alarm) is detected if the incoming data stream has
no transitions for a programmable number T consecutive pulse
positions. The number T is programmable by the PCD register and
can be calculated as follows:
T = 16 × (N+1); with 0 ≤ N ≤ 255.
The maximum time is: 256 × 16 × 648 ns = 2.65 ms. Every detected
pulse resets the internal pulse counter. The counter is clocked with
the receive clock RCLK.
Data Sheet
367
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Pulse Count Recovery (Read/Write)
Value after reset: 00H
PCR
PCR(7:0)
7
0
PCR7
PCR0
(39)
Pulse Count Recovery
A LOS alarm (red alarm) is cleared if a pulse-density is detected in the
received bit stream. The number of pulses M which must occur in the
predefined PCD time interval is programmable by the PCR register
and can be calculated as follows:
M = N+1; with 0 ≤ N ≤ 255.
The time interval starts with the first detected pulse transition. With
every received pulse a counter is incremented and the actual counter
is compared to the contents of PCR register. If the pulse number
reaches or exceeds the PCR value the LOS alarm is reset otherwise
the alarm stays active. In this case the next detected pulse transition
starts a new time interval.
An additional loss-of-signal recovery condition is selected by register
LIM2.LOS1.
Data Sheet
368
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Line Interface Mode 2 (Read/Write)
Value after reset: 20H
7
LIM2
LBO(2:1)
LBO2
0
LBO1
SLT1
SLT0
SCF
ELT
LOS1
(3A)
Line Build-Out
In long-haul applications LIM0.EQON = 1 a transmit filter can be
optionally placed on the transmit path to attenuate the data on pins
XL1/2. Selecting the transmitter attenuation is possible in steps of
7.5 dB at 772kHz which is according to FCC68 and ANSI T1.403.
To meet the line build-out defined by ANSI T1.403 registers XPM(2:0)
should be programmed as follows:
SLT(1:0)
00 =
0 dB
01 =
7.5 dB
→XPM(2:0) = 20H, 02H, 51H
10 =
-15 dB
→XPM(2:0) = 20H, 01H, 51H
11 =
-22.5 dB
→XPM(2:0) = 20H, 01H, 50H
Receive Slicer Threshold
00 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 55% of the peak amplitude.
01 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 67% of the peak amplitude (may be used in
some T1/J1 applications).
10 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 50% of the peak amplitude (default,
recommended in T1/J1 mode).
11 = The receive slicer generates a mark (digital one) if the voltage
at RL1/2 exceeds 45% of the peak amplitude.
SCF
Select Corner Frequency of DCO-R
Setting this bit reduces the corner frequency of the DCO-R circuit by
the factor of ten to 0.6 Hz.
Note: Reducing the corner frequency of the DCO-R circuitry
increases the synchronization time before the frequencies are
synchronized.
Data Sheet
369
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
ELT
Enable Loop-Timed
LOS1
0=
Normal operation
1=
Transmit clock is generated from the clock supplied by MCLK
which is synchronized to the extracted receive route clock. In
this configuration the transmit elastic buffer has to be enabled.
Refer to register FMR5.XTM. For correct operation of loop
timed the remote loop (bit LIM1.RL = 0) must be inactive and bit
CMR1.DXSS must be cleared.
Loss-of-Signal Recovery condition
0=
The LOS alarm is cleared if the predefined pulse-density
(register PCR) is detected during the time interval which is
defined by register PCD.
1=
Additionally to the recovery condition described above a LOS
alarm is only cleared if the pulse-density is fulfilled and no more
than 15 contiguous zeros are detected during the recovery
interval (according to GR-499-CORE).
Loop Code Register 1 (Read/Write)
Value after reset: 00H
7
LCR1
EPRM
XPRBS
EPRM
0
XPRBS
LDC1
LDC0
LAC1
LAC0
FLLB
LLBP
(3B)
Enable Pseudo-Random Binary Sequence Monitor
0=
Pseudo-random binary sequence (PRBS) monitor is disabled.
1=
PRBS is enabled. Setting this bit enables incrementing the bit
error counter BEC with each detected PRBS bit error. With any
change of state of the PRBS internal synchronization status an
interrupt ISR3.LLBSC is generated. The current status of the
PRBS synchronizer is indicated by bit FRS1.LLBAD.
Transmit Pseudo-Random Binary Sequence
A one in this bit position enables transmission of a pseudo-random
binary sequence to the remote end. Depending on bit LLBP the PRBS
is generated according to 215 -1 or 220-1 (ITU-T O. 151).
Data Sheet
370
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
LDC(1:0)
Length Deactivate (Down) Code
These bits defines the length of the LLB deactivate code which is
programmable in register LCR2.
00 = Length: 5 bit
01 = Length: 6 bit, 2 bit, 3 bit
10 = Length: 7 bit
11 = Length: 8 bit, 2 bit, 4bit
LAC(1:0)
Length Activate (Up) Code
These bits defines the length of the LLB activate code which is
programmable in register LCR3.
00 = Length: 5 bit
01 = Length: 6 bit, 2 bit, 3 bit
10 = Length: 7 bit
11 = Length: 8 bit, 2 bit, 4bit
FLLB
Framed Line Loop-Back/Invert PRBS
Depending on bit LCR1.XPRBS this bit enables different functions:
LCR1.XPRBS = 0:
0=
The line loop-back code is transmitted including framing bits.
LLB code overwrites the FS/DL-bits.
1=
The line loop-back code is transmitted unframed. LLB code
does not overwrite the FS/DL-bits.
Invert PRBS
LCR1.XPRBS = 1:
LLBP
0=
The generated PRBS is transmitted not inverted.
1=
The PRBS is transmitted inverted.
Line Loop-Back Pattern
LCR1.XPRBS = 0
0=
Fixed line loop-back code according to ANSI T1. 403.
1=
Enable user-programmable line loop-back code by register
LCR2/3.
LCR1.XPRBS = 1 or LCR1.EPRM = 1
Data Sheet
0=
215 -1
1=
220 -1
371
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Loop Code Register 2 (Read/Write)
Value after reset: 00H
LCR2
7
0
LDC7
LDC0
LDC(7:0)
(3C)
Line Loop-Back Deactivate Code
If enabled by bit FMR5.XLD = 1 the LLB deactivate code
automatically repeats until the LLB generator is stopped. Transmit
data is overwritten by the LLB code. LDC0 is transmitted last. For
correct operations bit LCR1.XPRBS has to cleared.
If LCR2 is changed while the previous deactivate code has been
detected and is still received, bit FRS1.LLBDD will stay active until the
incoming signal changes or a receiver reset is initiated
(CMDR.RRES = 1).
Loop Code Register 3 (Read/Write)
Value after reset: 00H
LCR3
LAC(7:0)
7
0
LAC7
LAC0
(3D)
Line Loop-Back Activate Code
If enabled by bit FMR5.XLU = 1 the LLB activate code automatically
repeats until the LLB generator is stopped. Transmit data is
overwritten by the LLB code. LAC0 is transmitted last. For correct
operations bit LCR1.XPRBS has to cleared.
If LCR3 is changed while the previous activate code has been
detected and is still received, bit FRS1.LLBAD will stay active until the
incoming signal changes or a receiver reset is initiated
(CMDR.RRES = 1).
Data Sheet
372
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
System Interface Control 1 (Read/Write)
Value after reset: 00H
7
SIC1
SSC(1:0)
SSC1
0
SSD1
RBS1
RBS0
SSC0
BIM
XBS1
XBS0
(3E)
Select System Clock
SIC1.SSC(1:0) and SIC2.SSC2 define the clocking rate on the
system highway.
SIC2.SSC2 = 0:
00 = 2.048 MHz
01 = 4.096 MHz
10 = 8.192 MHz
11 = 16.384 MHz
SIC2.SSC2 = 1:
00 = 1.544 MHz
01 = 3.088 MHz
10 = 6.176 MHz
11 = 12.352 MHz
SSD1
Select System Data Rate 1
SIC1.SSD1, FMR1.SSD0 and SIC2.SSC2 define the data rate on the
system highway. Programming SSD1/SSD0 and corresponding data
rate is shown below.
SIC2.SSC2 = 0:
00 = 2.048 Mbit/s
01 = 4.096 Mbit/s
10 = 8.192 Mbit/s
11 = 16.384 Mbit/s
SIC2 .SSC2 = 1:
00 =1.544 Mbit/s
01 = 3.088 Mbit/s
10 = 6.176 Mbit/s
11 = 12.352 Mbit/s
Data Sheet
373
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RBS(1:0)
Receive Buffer Size
00 = Buffer size: 2 frames
01 = Buffer size: 1 frame
10 = Buffer size: 96 bits
11 = Bypass of receive elastic store
BIM
Bit Interleaved Mode
Only applicable if bit SIC2.SSC2 is cleared. If SIC2.SSC2 is set high,
the bit interleaved mode is automatically performed.
XBS(1:0)
0=
Byte interleaved mode
1=
Bit interleaved mode
Transmit Buffer Size
00 = Bypass of transmit elastic store
01 = Buffer size: 1 frame
10 = Buffer size: 2 frames
11 = Buffer size: 96 bits
System Interface Control 2 (Read/Write)
Value after reset: 00H
7
SIC2
FFS
FFS
0
SSF
CRB
SSC2
SICS2
SICS1
SICS0
(3F)
Force Freeze Signaling
Setting this bit disables updating of the receive signaling buffer and
current signaling information is frozen. After resetting this bit and
receiving a complete superframe updating of the signaling buffer is
started again. The freeze signaling status can also be generated
automatically by detection of a loss-of-signal alarm or a loss of frame
alignment or a receive slip (only if external register access through
RSIG is enabled). This automatic freeze signaling function is logically
ored with this bit.
The current internal freeze signaling status is output on pin RP(A to
D) with selected pin function FREEZE (PC(4:1).RPC(2:0) = 110).
Additionally this status is also available in register SIS.SFS.
Data Sheet
374
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
SSF
Serial Signaling Format
Only applicable if pin function RSIG/XSIG and SIC3.TTRF = 0 is
selected.
CRB
0=
Bits 1 to 4 in all time slots except time slot 0 are cleared.
1=
Bits 1 to 4 in all time slots except time slot 0 are set high.
Center Receive Elastic Buffer
Only applicable if the time slot assigner is disabled
(PC(4:1).RPC(2:0) = 001B), no external or internal synchronous pulse
receive is generated.
A transition from low to high forces a receive slip and the read pointer
of the receive elastic buffer is centered. The delay through the buffer
is set to one half of the current buffer size. It should be hold high for
at least two 1.544 MHz periods before it is cleared.
SSC2
Select System Clock
This bit together with SIC1.SSC1/0 enables the system interface to
run with a clock of 1.544, 3.088, 6.176 or 12.352 MHz (SSC2 = 1) or
2.048, 4.096, 8.192 or 16.384 MHz (SSC2 = 0).
See also register SIC1.SSC1/0 on page 373.
SICS(2:0)
System Interface Channel Select
Only applicable if the system clock rate is greater than
1.544⁄2.048MHz.
Received data is transmitted on pin RDO/RSIG or received on
XDI⁄XSIG with the selected system data rate. If the data rate is greater
than 1.544/2.048 Mbit/s the data is output or sampled in half, a
quarter or one eighth of the time slot. Data is not repeated. The time
while data is active during a 8 × 488/648 ns time slot is called a
channel phase. RDO/RSIG are cleared (driven to low level) while
XDI⁄XSIG are ignored for the remaining time of the 8 × 488/648 ns or
for the remaining channel phases. The channel phases are selectable
with these bits.
Data Sheet
000 =
Data active in channel phase 1, valid if system data rate is
16/8/4 or 12/6/3 Mbit/s
001 =
Data active in channel phase 2, valid if data rate is 16/8/4 or
12/6/3 Mbit/s
010 =
Data active in channel phase 3, valid if data rate is 16/8 or
12/6 Mbit/s
011 =
Data active in channel phase 4, valid if data rate is 16/8 or
12/6 Mbit/s
375
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
100 =
Data active in channel phase 5, valid if data rate is 16 or
12 Mbit/s
101 =
Data active in channel phase 6, valid if data rate is 16 or
12 Mbit/s
110 =
Data active in channel phase 7, valid if data rate is 16 or
12 Mbit/s
111 =
Data active in channel phase 8, valid if data rate is 16 or
12 Mbit/s
System Interface Control 3(Read/Write)
Value after reset: 00H
7
SIC3
CMI
0
CMI
RESX
RESR
TTRF
DAF
(40)
Select CMI Precoding
Only valid if CMI code (FMR0.XC(1:0) = 01) is selected. This bit
defines
the CMI precoding and influences transmit and receive data.
0=
CMI with B8ZS precoding
1=
CMI without B8ZS precoding
Note:Before local loop is closed, B8ZS precoding has to be switched
off.
RESX
Rising Edge Synchronous Pulse Transmit
Depending on this bit all transmit system interface data and marker
are clocked or sampled with the selected active edge.
CMR2.IXSC = 0:
0
latched with the first falling edge of the selected PCM highway
clock.
1
latched with the first rising edge of the selected PCM highway
clock.
CMR2.IXSC = 1:
value of RESX bit has no impact on the selected edge of the PCM
highway clock but value of RESR bit is used as RESX.
Example: If RESR = 0, the rising edge of PCM highway clock is the
selected one for sampling data on XDI and vice versa.
Data Sheet
376
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RESR
Rising Edge Synchronous Pulse Receive
Depending on this bit all receive system interface data and marker are
clocked with the selected active edge.
0=
Latched with the first falling edge of the selected PCM highway
clock.
1=
Latched with the first rising edge of the selected PCM highway
clock.
Note: If bit CMR2.IRSP is set, the behavior of signal RFM (if used) is
inverse (1 = falling edge, 0 = rising edge)
TTRF
TTR Register Function (Fractional T1/J1 Access)
Setting this bit the function of the TTR(4:1) registers are changed. A
one in each TTR register forces the XSIGM marker high for the
corresponding time slot and controls sampling of the time slots
provided on pin XSIG. XSIG is selected by PC(4:1).XPC(3:0).
DAF
Data Sheet
Disable Automatic Freeze
0=
Signaling is automatically frozen if one of the following alarms
occurred: Loss-Of-signal (FRS0.LOS), Loss-of-FrameAlignment (FRS0.LFA), or receive slips (ISR3.RSP/N).
1=
Automatic freezing of signaling data is disabled. Updating of the
signaling buffer is also done if one of the above described alarm
conditions is active. However, updating of the signaling buffer
is stopped if SIC2.FFS is set. Significant only if the serial
signaling access is enabled.
377
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Clock Mode Register 1 (Read/Write)
Value after reset: 00H
7
0
CMR1
RS(1:0)
RS1
RS0
DCS
STF
DXJA
DXSS
(44)
Select RCLK Source
These bits select the source of RCLK.
00 = Clock recovered from the line through the DPLL drives RCLK
01 = Clock recovered from the line through the DPLL drives RCLK
and in case of an active LOS alarm RCLK pin is set high.
10 = Clock recovered from the line is de-jittered by DCO-R to drive a
2.048 MHz (SIC2.SSC2 = 0) or 1.544 MHz (SIC2.SSC2 = 1)
clock on RCLK.
11 = Clock recovered from the line is de-jittered by DCO-R to drive a
8.192 MHz (SIC2.SSC2 = 0) or 6.176 MHz (SIC2.SSC2 = 1)
clock on RCLK.
DCS
Disable Clock-Switching
In Slave mode (LIM0.MAS = 0) the DCO-R is synchronized on the
recovered route clock. In case of LOS the DCO-R switches
automatically to the clock sourced by port SYNC. Setting this bit
automatic switching from RCLK to SYNC is disabled.
STF
Select TCLK Frequency
Only applicable if the pin function TCLK port XP(A to D) is selected by
PC(4:1).XPC(3:0) = 0011B. Data on XL1/2, XDOP/N, XOID are
clocked with TCLK.
DXJA
0=
1.544 MHz
1=
6.176 MHz
Disable Internal Transmit Jitter Attenuation
Setting this bit disables the transmit jitter attenuation. Reading the
data out of the transmit elastic buffer and transmitting on XL1/2
(XDOP/N/XOID) is done with the clock provided on pin TCLK. In
transmit elastic buffer bypass mode the transmit clock is taken from
SCLKX, independent of this bit.
Data Sheet
378
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
DXSS
DCO-X Synchronization Clock Source
0=
The DCO-X circuitry synchronizes to the internal reference
clock which is sourced by SCLKX/R or RCLK. Since there are
many reference clock opportunities the following internal
prioritizing in descending order from left to right is realized:
LIM1.RL > CMR1.DXSS > LIM2.ELT > current working clock of
transmit system interface.
If one of these bits is set the corresponding reference clock is
taken.
1=
DCO-X synchronizes to an external reference clock provided
on pin XP(A to D) pin function TCLK, if no remote loop is active.
TCLK is selected by PC(4:1).XPC(3:0) = 0011B
Clock Mode Register 2 (Read/Write)
Value after reset: 00H
7
0
CMR2
DCOXC
DCF
Data Sheet
DCOXC
DCF
IRSP
IRSC
IXSP
IXSC
(45)
DCO-X Center-Frequency Enable
0=
The center function of the DCO-X circuitry is disabled.
1=
The center function of the DCO-X circuitry is enabled.
DCO-X centers to 1.544 MHz related to the master clock
reference (MCLK), if reference clock (e.g. SCLKX) is missing.
DCO-R Center- Frequency Disabled
0=
The DCO-R circuitry is frequency centered
- in master mode if no 1.544 or 2.048 MHz reference clock on
pin SYNC is provided or
- in slave mode if a loss-of-signal occurs in combination with no
1.544 or 2.048 MHz clock on pin SYNC or
- a gapped clock is provided on pin RCLKI and this clock is
inactive or stopped.
1=
The center function of the DCO-R circuitry is disabled. The
generated clock (DCO-R) is frequency frozen in that moment
when no clock is available on pin SYNC or pin RCLKI. The
DCO-R circuitry starts synchronization as soon as a clock on
pins SYNC or RCLKI appears.
379
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
IRSP
Internal Receive System Frame Sync Pulse
0=
The frame sync pulse for the receive system interface is
sourced by SYPR (if SYPR is applied). If SYPR is not applied,
the frame sync pulse is derived from RDO output signal
internally free running).
The use of IRSP = 0 is recommended.
1=
The frame sync pulse for the receive system interface is
internally sourced by the DCO-R circuitry. This internally
generated frame sync signal can be output (active low) on
multifunction ports RP(A to D) (RPC(2:0) = 001B).
Note: This is the only exception where the use of RFM and
SYPR is allowed at the same time. Because only one set of
offset registers (RC1/0) is available, programming is done by
using the SYPR calculation formula in the same way as for the
external SYPR pulse. Bit IRSC must be set for correct
operation.
IRSC
IXSP
IXSC
Data Sheet
Internal Receive System Clock
0=
The working clock for the receive system interface is sourced
by SCLKR of or in receive elastic buffer bypass mode from the
corresponding extracted receive clock RCLK.
1=
The working clock for the receive system interface is sourced
internally by DCO-R or in bypass mode by the extracted receive
clock. SCLKR is ignored.
Internal Transmit System Frame Sync Pulse
0=
The frame sync pulse for the transmit system interface is
sourced by SYPX.
1=
The frame sync pulse for the transmit system interface is
internally sourced by the DCO-R circuitry. Additionally, the
external XMFS signal defines the transmit multiframe begin.
XMFS is enabled or disabled by the multifunction port
configuration. For correct operation bits CMR2.IXSC/IRSC
must be set. SYPX is ignored.
Internal Transmit System Clock
0=
The working clock for the transmit system interface is sourced
by SCLKX.
1=
The working clock for the transmit system interface is sourced
internally by the working clock of the receive system interface.
SCLKX is ignored.
380
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Global Configuration Register (Read/Write)
Value after reset: 00H
7
GCR
VIS
SCI
SES
ECMC
PD
VIS
0
SCI
SES
ECMC
PD
(46)
Masked Interrupts Visible
0=
Masked interrupt status bits are not visible in registers ISR(5:0).
1=
Masked interrupt status bits are visible in ISR(5:0), but they are
not visible in registers GIS.
Status Change Interrupt
0=
Interrupts are generated either on activation or deactivation of
the internal interrupt source.
1=
The following interrupts are activated both on activation and
deactivation of the internal interrupt source:
ISR2.LOS, ISR2.AIS and ISR0.PDEN
Select External Second Timer
0=
Internal second timer selected
1=
External second timer selected
Error Counter Mode COFA
0=
Not defined; reserved for future applications.
1=
A Change of Frame or Multiframe Alignment COFA is detected
since the last resynchronization. The events are accumulated
in the COFA event counter COEC.(1:0).
Multiframe periods received in the asynchronous state are
accumulated in the COFA event counter COEC.(7:2).
An overflow of each counter is disabled.
Power Down
Switches between power-up and power-down mode.
Data Sheet
0=
Power up
1=
Power down
All outputs are driven inactive, except the multifunction ports,
which are weakly driven high by the internal pullup devices.
381
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Errored Second Mask (Read/Write)
Value after reset: FFH
7
ESM
LFA
ESM
0
FER
CER
AIS
LOS
CVE
SLIP
(47)
Errored Second Mask
This register functions as an additional mask register for the interrupt
status bit Errored Second (ISR3.ES). A "1" in a bit position of ESM
deactivates the related second interrupt.
Disable Error Counter (Write)
Value after reset: 00H
7
DEC
DRBD
DRBD
0
DCOEC
DBEC
DCEC
DEBC
DCVC
DFEC
(60)
Disable Receive Buffer Delay
This bit has to be set before reading the register RBD. It is
automatically reset if RBD has been read.
DCOEC
Disable COFA Event Counter
DBEC
Disable PRBS Bit Error Counter
Only valid if LCR1.EPRM = 1 and FMR1.ECM are reset.
DCEC
Disable CRC Error Counter
DEBC
Disable Errored Block Counter
DCVC
Disable Code Violation Counter
DFEC
Disable Framing Error Counter
These bits are only valid if FMR1.ECM is cleared. They have to be set
before reading the error counters. They are reset automatically if the
corresponding error counter high byte has been read. With the rising
edge of these bits the error counters are latched and then cleared.
Note: Error counters and receive buffer delay can be read 1 µs after setting the
according bit in bit DEC.
Data Sheet
382
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Transmit Signaling Register (Write)
Value after reset: not defined
Table 65
Transmit Signaling Registers (T1/J1)
7
0
XS1
A1
B1
C1/A2
D1/B2
A2/A3
B2/B3
C2/A4
D2/B4
(70)
XS2
A3/A5
B3/B5
C3/A6
D3/B6
A4/A7
B4/B7
C4/A8
D4/B8
(71)
XS3
A5/A9
B5/B9
C5/A10
D5/B10
A6/A11
B6/B11
C6/A12
D6/B12
(72)
XS4
A7/A13
B7/B13
C7/A14
D7/B14
A8/A15
B8/B15
C8/A16
D8/B16
(73)
XS5
A9/A17
B9/B17
C9/A18
D9/B18
A10/A19 B10/B19 C10/A20 D10/B20
(74)
XS6
A11/A21 B11/B21 C11/A22 D11/B22 A12/A23 B12/B23 C12/A24 D12/B24
(75)
XS7
A13/A1
B13/B1
C13/A2
D13/B2
A14/A3
B14/B3
C14/A4
D14/B4
(76)
XS8
A15/A5
B15/B5
C15/A6
D15/B6
A16/A7
B16/B7
C16/A8
D16/B8
(77)
XS9
A17/A9
B17/B9
C17/A10 D17/B10 A18/A11 B18/B11 C18/A12 D18/B12
(78)
XS10
A19/A13 B19/B13 C19/A14 D19/B14 A20/A15 B20/B15 C20/A16 D20/B16
(79)
XS11
A21/A17 B21/B17 C21/A18 D21/B18 A22/A19 B22/B19 C22/A20 D22/B20
(7A)
XS12
A23/A21 B23/B21 C23/A22 D23/B22 A24/A23 B24/B23 C24/A24 D24/B24
(7B)
Transmit Signaling Register 1 to 12
The transmit signaling register access is enabled by setting bit FMR5.EIBR = 1. Each
register contains the bit robbing information for 8 DS0 channels. With the transmit CAS
empty interrupt ISR1.CASE the contents of these registers is copied into a shadow
register. The contents is subsequently sent out in the corresponding bit positions of the
next outgoing multiframe. XS1.7 is sent out first in channel 1 frame 1 and XS12.0 is sent
out last. The transmit CAS empty interrupt ISR1.CASE requests that these registers
should be serviced within the next 3 ms. If requests for new information are ignored,
current contents is repeated.
Note: If access to XS(12:1) registers is done without control of the interrupt ISR1.CASE
and the write access to these registers is done exact in that moment when this
interrupt is generated, data is lost.
A software reset (CMDR.XRES) resets these registers.
Data Sheet
383
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Port Configuration 1 to 4 (Read/Write)
Value after reset: 00H
7
0
PC1
RPC12
RPC11
RPC10
XPC13
XPC12
XPC11
XPC10
(80)
PC2
RPC22
RPC21
RPC20
XPC23
XPC22
XPC21
XPC20
(81)
PC3
RPC32
RPC31
RPC30
XPC33
XPC32
XPC31
XPC30
(82)
PC4
RPC42
RPC41
RPC40
XPC43
XPC42
XPC41
XPC40
(83)
RPC(2:0)
Receive multifunction port configuration
The multifunction ports RP(A to D) are bidirectional. After Reset these
ports are configured as inputs. With the selection of the pin function
the In/Output configuration is also achieved. The input function SYPR
may only be selected once, it must not be selected twice or more.
Register PC1 configures port RPA, while PC2 → port RPB,
PC3 → port RPC and PC4 → port RPD.
000 = SYPR: Synchronous Pulse Receive (Input)
Together with register RC(1:0) SYPR defines the frame begin
on the receive system interface. Because of the offset
programming the SYPR and the RFM pin function cannot be
selected in parallel.
001 = RFM: Receive Frame Marker (Output)
CMR2.IRSP = 0:
The receive frame marker is active high for one 1.544 MHz
period during any bit position of the current frame.
Programming of the bit position is done by using registers
RC(1:0). The internal time slot assigner is disabled. The RFM
offset calculation formula has to be used.
CMR2.IRSP = 1:
Internally generated frame synchronization pulse sourced by
the DCO-R circuitry. The pulse is active low for one 1.544 MHz
period.
010 = RMFB: Receive Multiframe Begin (Output)
Marks the beginning of every received multiframe or
optionally the begin of every CAS multiframe begin (active
high).
Data Sheet
384
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
011 = RSIGM: Receive Signaling Marker (Output)
Marks the time slots which are defined by register RTR(4:1)
of every frame on port RDO.
100 = RSIG: Receive Signaling Data (Output)
The received CAS multiframe is transmitted on this pin. Time
slot on RSIG correlates directly to the time slot assignment on
RDO.
101 = DLR: Data Link Bit Receive (Output)
Marks the Sa-bits within the data stream on RDO.
110 = FREEZE: Freeze Signaling (Output)
The freeze signaling status is active high by detecting a Lossof-signal alarm, or a Loss of CAS Frame Alignment or a
receive slip (positive or negative). It stays high for at least one
complete multiframe after the alarm disappears. Setting
SIC2.FFS enforces a high on pin FREEZE.
111 = RFSP: Receive Frame Synchronous Pulse (Output)
Marks the frame begin in the receivers synchronous state.
This marker is active low for 488 ns with a frequency of 8 kHz.
XPC(3:0)
Transmit multifunction Port Configuration
The multifunction ports XP(A to D) are bidirectional. After Reset these
ports are configured as inputs. With the selection of the pin function
the In/Output configuration is also achieved. Each of the four different
input functions (SYPX, XMFS, XSIG, TCLK) may only be selected
once. No input function must be selected twice or more. SYPX and
XMFS should not be selected in parallel. Register PC1 configures
port XPA, while PC2 → port XPB, PC3 → port XPC and PC4 → port
XPD.
0000 = SYPX: Synchronous Pulse Transmit (Input)
Together with register XC(1:0) SYPX defines the frame begin
on the transmit system interface ports XDI and XSIG.
0001 = XMFS: Transmit Multiframe Synchronization (Input)
Together with register XC(1:0) XMFS defines the frame and
multiframe begin on the transmit system interface ports XDI
and XSIG. Depending on PC5.CXMFS the signal on XMFS is
active high or low.
0010 = XSIG: Transmit Signaling Data (Input)
Input for transmit signaling data received from the signaling
highway. Optionally sampling of XSIG data is controlled by
the active high XSIGM marker.
Data Sheet
385
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
0011 = TCLK: Transmit Clock (Input)
A 1.544/6.176MHz clock has to be sourced by the system if
the internal generated transmit clock (DCO-X) is not used.
Optionally this input is used as a synchronization clock for the
DCO-X circuitry with a frequency of 1.544 or 6.176 MHz.
0100 = XMFB: Transmit Multiframe Begin (Output)
Marks the beginning of every transmit multiframe.
0101 = XSIGM: Transmit Signaling Marker (Output)
Marks the time slots which are defined by register TTR(4:1) of
every frame on port XDI.
0110 = DLX: Data Link Bit Transmit (Output)
Marks the Sa-bits within the data stream on XDI.
0111 = XCLK: Transmit Line Clock (Output)
Frequency: 1.544MHz
1000 = XLT: Transmit Line Tristate (Input)
With a high level on this port the transmit lines XL1/2 or
XDOP/N are set directly into tristate. This pin function is
logically ored with register XPM2.XLT.
Port Configuration 5 (Read/Write)
Value after reset: 00H
7
0
PC5
CCLK2
CCLK1
CXMFS
Data Sheet
CCLK2
CCLK1
CXMFS
0
CSRP
CRP
(84)
Configure CLK2 Port
0=
CLK2 is input
1=
CLK2 is output (only if DCO-X is active)
Configure CLK1 Port
0=
CLK1 is input
1=
CLK1 is output (only if DCO-R is active)
Configure XMFS Port
0=
Port XMFS is active low.
1=
Port XMFS is active high.
386
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
P C5(2)
reserved.
Must be cleared
CSRP
Configure SCLKR Port
CRP
0=
SCLKR: Input
1=
SCLKR: Output
Configure RCLK Port
0=
RCLK: Input
1=
RCLK: Output
Global Port Configuration 1 (Read/Write)
Value after reset: 00H
7
0
GPC1
CSFP1
CSFP0
(85)
CSFP(1:0)
Configure SEC/FSC Port
The FSC pulse is generated if the DCO-R circuitry of the selected
channel is active (CMR2.IRSC = 1 or CMR1.RS(1:0) = 10B or 11B).
00 = SEC: Input, active high
01 = SEC: Output, active high
10 = FSC: Output, active high
11 = FSC: Output, active low
Data Sheet
387
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Port Configuration 6 (Read/Write)
Value after reset: 00H
7
0
PC6
SXCL(1:0)
SXCL1
SXCL0
SCL2
SCL1
SCL0
(86)
Select Transmit Clock Frequency on Port CLK2
Port CLK2 is the de-jittered DCO-X clock at a frequency of
00 = 1.544 MHz
01 = 3.088MHz
10 = 6.176 MHz
11 = 12.352 MHz
Note: If DCO-X is not used, no clock is output on pin CLK2
(SIC1.XBS(1:0)=00 and CMR1.DXJA=1; buffer bypass and
no jitter attenuation)
SCL(2:0)
Select System Clock Frequency on Port CLK1
Port CLK1 is the de-jittered DCO-R clock at a frequency of
SIC2.SSC2=0:
000 = 8 kHz
001 = 2.048 MHz
010 = 4.096 MHz
011 = 8.192 MHz
100 = 16.384 MHz
101 to 111 = Not defined
SIC2.SSC2=1:
000 = 8 kHz
001 = 1.544 MHz
010 = 3.088 MHz
011 = 6.176 MHz
100 = 12.352 MHz
101 to 111 = Not defined
Note:If DCO-R is not active, no clock is output on pin CLK1
(SIC1.RBS(1:0)=11 and CMR1.RS1=0).
Data Sheet
388
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Command Register 2 (Write)
Value after reset: 00H
CMDR2
RSUC
RSUC
XPPR
(87)
Reset Signaling Unit Counter - HDLC Channel 1
After setting this bit the SS7 signaling unit counter and error counter
are reset.The bit is cleared automatically after execution.
Note: The maximum time between writing to the CMDR2 register
and the execution of the command takes 2.5 periods of the
current system data rate. Therefore, if the CPU operates with
a very high clock rate in comparison with the FALC56's clock,
it is recommended that bit SIS.CEC should be checked before
writing to the CMDR register to avoid any loss of commands.
XPPR
Transmit Periodical Performance Report (PPR)
After setting this bit the last PPR is sent once. The bit is cleared
automatically after completion. Applies to HDLC channel 1 only.
Command Register 3 (Write)
Value after reset: 00H
7
CMDR3
RMC2
RMC2
0
XREP2
XHF2
XTF2
XME2
SRES2
(88)
Receive Message Complete - HDLC Channel 2
Confirmation from CPU to FALC® that the current frame or data block
has been fetched following an RPF2 or RME2 interrupt, thus the
occupied space in the RFIFO2 can be released.
XREP2
Transmission Repeat - HDLC Channel 2
If XREP2 is set together with XTF2 (write 24H to CMDR3), the FALC®
repeatedly transmits the contents of the XFIFO2 (1 to 32 bytes)
without HDLC framing fully transparently, i.e. without flag, CRC.
The cyclic transmission is stopped with an SRES2 command or by
resetting XREP2.
Data Sheet
389
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XHF2
Transmit HDLC Frame - HDLC Channel 2
After having written up to 32 bytes to the XFIFO2, this command
initiates the transmission of a HDLC frame.
XTF2
Transmit Transparent Frame - HDLC Channel 2
Initiates the transmission of a transparent frame without HDLC
framing.
XME2
Transmit Message End - HDLC Channel 2
Indicates that the data block written last to the XFIFO2 completes the
current frame. The FALC® can terminate the transmission operation
properly by appending the CRC and the closing flag sequence to the
data.
SRES2
Signaling Transmitter Reset - HDLC Channel 2
The transmitter of the signaling controller is reset. XFIFO2 is cleared
of any data and an abort sequence (seven 1s) followed by interframe
time fill is transmitted. In response to SRES2 an XPR2 interrupt is
generated.
This command can be used by the CPU to abort a frame currently in
transmission.
Command Register 4 (Write)
Value after reset: 00H
7
CMDR4
RMC3
RMC3
0
XREP3
XHF3
XTF3
XME3
SRES3
(89)
Receive Message Complete - HDLC Channel 3
Confirmation from CPU to FALC® that the current frame or data block
has been fetched following an RPF3 or RME3 interrupt, thus the
occupied space in the RFIFO3 can be released.
XREP3
Transmission Repeat - HDLC Channel 3
If XREP3 is set together with XTF3 (write 24H to CMDR4), the FALC®
repeatedly transmits the contents of the XFIFO3 (1 to 32 bytes)
without HDLC framing fully transparently, i.e. without flag, CRC.
The cyclic transmission is stopped with an SRES3 command or by
resetting XREP3.
Data Sheet
390
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XHF3
Transmit HDLC Frame - HDLC Channel 3
After having written up to 32 bytes to the XFIFO3, this command
initiates the transmission of a HDLC frame.
XTF3
Transmit Transparent Frame - HDLC Channel 3
Initiates the transmission of a transparent frame without HDLC
framing.
XME3
Transmit Message End - HDLC Channel 3
Indicates that the data block written last to the XFIFO3 completes the
current frame. The FALC® can terminate the transmission operation
properly by appending the CRC and the closing flag sequence to the
data.
SRES3
Signaling Transmitter Reset - HDLC Channel 3
The transmitter of the signaling controller is reset. XFIFO3 is cleared
of any data and an abort sequence (seven 1s) followed by interframe
time fill is transmitted. In response to SRES3 an XPR3 interrupt is
generated.
This command can be used by the CPU to abort a frame currently in
transmission.
Common Configuration Register 3 (Read/Write)
Value after reset: 00H
7
0
CCR3
RADD2
RCRC2
XCRC2
ITF2
XMFA2
RADD2
Receive Address Pushed to RFIFO2
RFT12
RFT02
(8B)
If this bit is set, the received HDLC channel 2 address information (1
or 2 bytes, depending on the address mode selected via
MODE2.MDS02) is pushed to RFIFO2. This function is applicable in
non-auto mode and transparent mode 1.
Data Sheet
391
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RCRC2
Receive CRC ON/OFF - HDLC Channel 2
Only applicable in non-auto mode.
If this bit is set, the received CRC checksum is written to RFIFO2
(CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in
the received frame, is followed in the RFIFO2 by the status
information byte (contents of register RSIS2). The received CRC
checksum will additionally be checked for correctness. If non-auto
mode is selected, the limits for “valid frame” check are modified.
XCRC2
Transmit CRC ON/OFF - HDLC Channel 2
If this bit is set, the CRC checksum will not be generated internally. It
has to be written as the last two bytes in the transmit FIFO (XFIFO2).
The transmitted frame is closed automatically with a closing flag.
ITF2
Interframe Time Fill - HDLC Channel 2
Determines the idle (= no data to be sent) state of the transmit data
coming from the signaling controller.
XMFA2
0=
Continuous logical "1" is output
1=
Continuous flag sequences are output ("01111110" bit patterns)
Transmit Multiframe Aligned - HDLC Channel 2
Determines the synchronization between the framer and the
corresponding signaling controller.
RFT12, RFT02
0=
The contents of the XFIFO2 is transmitted without multiframe
alignment.
1=
The contents of the XFIFO2 is transmitted multiframe aligned.
RFIFO2 Threshold Level - HDLC Channel 2
The size of the accessible part of RFIFO2 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT12
RFT02
Size of Accessible Part of RFIFO2
0
0
1
1
0
1
0
1
32 bytes (default value)
16 bytes
4 bytes
2 bytes
The value of RFT(1:0)2 can be changed dynamically if reception is
not running or after the current data block has been read, but before
the command CMDR3.RMC2 is issued (interrupt controlled data
transfer).
Data Sheet
392
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Common Configuration Register 4 (Read/Write)
Value after reset: 00H
7
0
CCR4
RADD3
RCRC3
XCRC3
ITF3
XMFA3
RADD3
Receive Address Pushed to RFIFO3
RFT13
RFT03
(8C)
If this bit is set, the received HDLC channel 3 address information (1
or 2 bytes, depending on the address mode selected via
MODE3.MDS03) is pushed to RFIFO3. This function is applicable in
non-auto mode and transparent mode 1.
RCRC3
Receive CRC ON/OFF - HDLC Channel 3
Only applicable in non-auto mode.
If this bit is set, the received CRC checksum is written to RFIFO3
(CRC-ITU-T: 2 bytes). The checksum, consisting of the 2 last bytes in
the received frame, is followed in the RFIFO3 by the status
information byte (contents of register RSIS3). The received CRC
checksum will additionally be checked for correctness. If non-auto
mode is selected, the limits for “Valid Frame” check are modified.
XCRC3
Transmit CRC ON/OFF - HDLC Channel 3
If this bit is set, the CRC checksum will not be generated internally. It
has to be written as the last two bytes in the transmit FIFO (XFIFO3).
The transmitted frame is closed automatically with a closing flag.
ITF3
Interframe Time Fill - HDLC Channel 3
Determines the idle (= no data to be sent) state of the transmit data
coming from the signaling controller.
XMFA3
0=
Continuous logical "1" is output
1=
Continuous flag sequences are output ("01111110" bit patterns)
Transmit Multiframe Aligned - HDLC Channel 3
Determines the synchronization between the framer and the
corresponding signaling controller.
Data Sheet
0=
The contents of the XFIFO3 is transmitted without multiframe
alignment.
1=
The contents of the XFIFO3 is transmitted multiframe aligned.
393
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RFT13, RFT03
RFIFO3 Threshold Level - HDLC Channel 3
The size of the accessible part of RFIFO3 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT13
RFT03
Size of Accessible Part of RFIFO3
0
0
1
1
0
1
0
1
32 bytes (default value)
16 bytes
4 bytes
2 bytes
The value of RFT13/03 can be changed dynamically if reception is not
running or after the current data block has been read, but before the
command CMDR4.RMC3 is issued (interrupt controlled data
transfer).
Common Configuration Register 5 (Read/Write)
Value after reset: 00H
7
0
CCR5
SUET
CSF
AFX
CR
EPR
(8D)
Note: SUET, CSF and AFX are only valid, if SS7 mode is selected.
CR and EPR are only valid, if PPR mode is selected.
SUET
CSF
Signaling Unit Error Threshold - HDLC Channel 1
Defines the number of signaling units received in error that will cause
an error rate high indication (ISR1.SUEX).
0=
Threshold 64 errored signaling units
1=
Threshold 32 errored signaling units
Compare Status Field - HDLC Channel 1
If the status fields of consecutive LSSUs are equal, only the first is
stored and every following is ignored.
Data Sheet
0=
Compare disabled.
1=
Compare enabled.
394
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
AFX
Automatic FISU Transmission - HDLC Channel 1
After the contents of the transmit FIFO (XFIFO) has been transmitted
completely, FISUs are transmitted automatically. These FISUs
contain the FSN and BSO of the last transmitted signaling unit
(provided in XFIFO).
CR
0=
Automatic FISU transmission disabled.
1=
Automatic FISU transmission enabled.
Command Response - HDLC Channel 1
Reflects the status of the CR bit in the SAPI octet transmitted during
Periodical Performance Report (PPR), if CCR5.EPR = 1.
EPR
0=
CR bit = 0
1=
CR bit = 1
Enable Periodical Performance Report (PPR) - HDLC Channel 1
If the periodical performance report is to be used, an HDLC format
must be selected by MODE.MDS(2:0).
0 = PPR disabled.
1=
PPR enabled.
Mode Register 2 (Read/Write)
Value after reset: 00H
7
MODE2
MDS22
MDS2(2:0)
0
MDS21
MDS20
HRAC2
DIV2
(8E)
Mode Select - HDLC Channel 2
The operating mode of the HDLC controller is selected.
000 = Reserved
001 = Reserved
010 = One-byte address comparison mode (RAL1, 2)
011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2)
100 = No address comparison
101 = One-byte address comparison mode (RAH1, 2)
110 = Reserved
111 = No HDLC framing mode 1
Data Sheet
395
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
HRAC2
Receiver Active - HDLC Channel 2
Switches the HDLC receiver to operational or inoperational state.
DIV2
0=
Receiver inactive
1=
Receiver active
Data Inversion - HDLC Channel 2
Setting this bit will invert the internal generated HDLC data stream.
0=
Normal operation, HDLC data stream not inverted
1=
HDLC data stream inverted
Mode Register 3 (Read/Write)
Value after reset: 00H
7
MODE3
MDS32
MDS3(2:0)
0
MDS31
MDS30
HRAC3
DIV3
(8F)
Mode Select - HDLC Channel 3
The operating mode of the HDLC controller is selected.
000 = Reserved
001 = Reserved
010 = One-byte address comparison mode (RAL1, 2)
011 = Two-byte address comparison mode (RAH1, 2 and RAL1, 2)
100 = No address comparison
101 = One-byte address comparison mode (RAH1, 2)
110 = Reserved
111 = No HDLC framing mode 1
HRAC3
Receiver Active - HDLC Channel 3
Switches the HDLC receiver to operational or inoperational state.
Data Sheet
0=
Receiver inactive
1=
Receiver active
396
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
DIV3
Data Inversion - HDLC Channel 3
Setting this bit will invert the internal generated HDLC data stream.
0=
Normal operation, HDLC data stream not inverted
1=
HDLC data stream inverted
Global Clock Mode Register 1 (Read/Write)
Value after reset: 00H
7
GCM1
0
PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1 PHD_E1
7
6
5
4
3
2
1
0
PHD_E1(7:0)
(92)
Frequency Adjust for E1
For details see calculation formulas below.
Global Clock Mode Register 2 (Read/Write)
Value after reset: 00H
7
GCM2
0
DVM_E1 DVM_E1 DVM_E1 VFREQ_ PHD_E1 PHD_E1 PHD_E1 PHD_E1
2
1
0
EN
11
10
9
8
PHD_E1(11:8)
(93)
Frequency Adjust for E1
For details see calculation formulas below.
VFREQ_EN
Data Sheet
Variable Frequency Enable
0=
Fixed clock frequency of 2.048 (E1) or 1.544 MHz (T1/J1)
1=
Variable master clock frequency
397
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
DVM_E1(2:0)
Divider Mode for E1
000 = Not valid
001 = Divide by DIV_E1 = 3
010 = Divide by DIV_E1 = 4 1/6
011 = Divide by DIV_E1 = 4
100 = Divide by DIV_E1 = 5.5
101 = Divide by DIV_E1 = 5 1/3
110 = Divide by DIV_E1 = 5 2/3
111 = Not valid
Global Clock Mode Register 3 (Read/Write)
Value after reset: 00H
7
GCM3
0
PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1 PHD_T1
7
6
5
4
3
2
1
0
PHD_T1(7:0)
(94)
Frequency Adjust for T1
For details see calculation formulas below.
Data Sheet
398
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Global Clock Mode Register 4 (Read/Write)
Value after reset: 00H
7
GCM4
0
DVM_T1 DVM_T1 DVM_T1
2
1
0
PHD_T1(11:8)
0
PHD_T1 PHD_T1 PHD_T1 PHD_T1
11
10
9
8
(95)
Frequency Adjust for T1
For details see calculation formulas below.
DVM_T1(2:0)
Divider Mode for T1
000 = Not valid
001 = Divide by DIV_T1 = 3
010 = Divide by DIV_T1 = 4 1/6
011 = Divide by DIV_T1 = 4
100 = Divide by DIV_T1 = 5.5
101 = Divide by DIV_T1 = 5 1/3
110 = Divide by DIV_T1 = 5 2/3
111 = Not valid
GCM4.4
reserved
Must be cleared.
Data Sheet
399
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Global Clock Mode Register 5 (Read/Write)
Value after reset: 00H
7
GCM5
0
MCLK_
LOW
MCLK_LOW
PLL_M(0:4)
PLL_M
4
PLL_M
3
PLL_M
2
PLL_M
1
PLL_M
0
(96)
Master Clock Range Low
0=
Master clock frequency divided by (PLL_M+1) is greater than or
equal 1.5 MHz
1=
Master clock frequency divided by (PLL_M+1) is less than 1.5
MHz
PLL Dividing Factor M
For details see calculation formulas below.
Note: Write operations to GCM5 initiate a PLL reset (see below).
Global Clock Mode Register 6 (Read/Write)
Value after reset: 00H
7
GCM6
PLL_N(4:0)
0
PLL_N
4
PLL_N
3
PLL_N
2
PLL_N
1
PLL_N
0
(97)
PLL Dividing Factor N
For details see calculation formulas below.
Note: Write operations to GCM6 initiate a PLL reset (see below).
Data Sheet
400
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Flexible Clock Mode Settings
If flexible master clock mode is used (VFREQ_EN = 1), the according register settings
can be calculated as follows (a windows-based program for automatic calculation is
available, see Chapter 13.3 on page 481). For some of the standard frequencies see
the table below.
1. PLL_M and PLL_N must fulfill the equations:
a. 1.5 MHz ≤ fMCLK / (PLL_M+1) ≤ 2.048 MHz
b. If (a.) is not possible, set MCLK_LOW and fulfill
1.02 MHz ≤ fMCLK / (PLL_M+1) ≤ 1.5 MHz
c. 65 MHz ≤ fMCLK × (2×PLL_N+2) / (PLL_M+1) ≤ 69.7 MHz
(as high as possible within this range)
2. Selection of dividing mode to best fulfill:
foutE1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_E1 (target E1: 16.384 MHz)
foutT1 = ( fMCLK × (2×PLL_N+2) / (PLL_M+1) ) / DIV_T1 (target T1: 12.352 MHz)
Though the target frequency might not be met directly, the dividing mode has to be
selected to reach a frequency, which is as near as possible to the target frequency.
3. Calculation of correction value (frequency mismatch correction)
PHD_E1 = 6 × 4096 × [DIV_E1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/16.384 MHz)]
PHD_T1 = 6 × 4096 × [DIV_T1 - (2×PLL_N+2)/(PLL_M+1) × (fMCLK/12.352 MHz)]
The result of these equations will be in the range of -2048 to +2047. Negative values are
represented in 2s-complement format (e.g. -2000D = 830H; +2000D = 7D0H).
Table 66
Clock Mode Register Settings for E1 or T1/J1
fMCLK [MHz]
GCM1
GCM2
GCM3
GCM4
GCM5
GCM6
1.544
F0H
51H
00H
80H
00H
15H
2.048
00H
58H
D2H
C2H
00H
10H
8.192
00H
58H
D2H
C2H
03H
10H
10.000
90H
51H
81H
8FH
04H
10H
12.352
F0H
51H
00H
80H
07H
15H
Data Sheet
401
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Transmit FIFO 2 (Write)
Value after reset: 00H
7
0
XFIFO2
XF7
XF0
(9C)
XFIFO2
XF15
XF8
(9D)
XF(15:0)
Transmit FIFO - HDLC Channel 2
The function is equivalent to XFIFO.
Transmit FIFO 3 (Write)
Value after reset: 00H
7
0
XFIFO3
XF7
XF0
(9E)
XFIFO3
XF15
XF8
(9F)
XF(15:0)
Transmit FIFO - HDLC Channel 3
The function is equivalent to XFIFO.
Time Slot Even/Odd Select (Read/Write)
Value after reset: 00H
7
TSEO
0
EO31
EO30
EO21
EO20
EO11
EO10
(A0)
HDLC protocol data can be sent in even, odd or both frames of a multiframe. Even
frames are frame number 2, 4, and so on, odd frames are frame number 1, 3, and so on.
The selection refers to receive and transmit direction as well. Each multiframe starts with
an odd frame and ends with an even frame. By default all frames are used for HDLC
reception and transmission.
Note: The different HDLC channels have to be configured to use different time slots, bit
positions or frames.
Data Sheet
402
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
EO1(1:0)
Even/Odd frame selection - HDLC Channel 1
Channel 1 HDLC protocol data can be sent in even, odd or both
frames of a multiframe.
00 = Even and odd frames
01 = Odd frames only
10 = Even frames only
11 = Undefined
EO2(1:0)
Even/Odd frame selection - HDLC Channel 2
Channel 2 HDLC protocol data can be sent in even, odd or both
frames of a multiframe.
00 = Even and odd frames
01 = Odd frames only
10 = Even frames only
11 = Undefined
EO3(1:0)
Even/Odd frame selection - HDLC Channel 3
Channel 3 HDLC protocol data can be sent in even, odd or both
frames of a multiframe.
00 = Even and odd frames
01 = Odd frames only
10 = Even frames only
11 = Undefined
Time Slot Bit Select 1 (Read/Write)
Value after reset: FFH
7
TSBS1
TSB17
TSB1(7:0) =
0
TSB16
TSB15
TSB14
TSB13
TSB12
TSB11
TSB10
(A1)
Time Slot Bit Selection - HDLC Channel 1
Only bits selected by this register are used for HDLC channel 1 in
selected time slots. Time slot selection is done by setting the
appropriate bits in registers TTR(4:1) and RTR(4:1) independently
for receive and transmit direction. Bit selection is common to receive
and transmit direction. By default all bit positions within the selected
time slot(s) are enabled.
TSB1x = 0 to bit position x in selected time slot(s) is not used for
HDLC channel 1 reception and transmission.
Data Sheet
403
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
TSB1x = 1 to bit position x in selected time slot(s) is used for HDLC
channel 1 reception and transmission.
Time Slot Bit Select 2 (Read/Write)
Value after reset: FFH
7
TSBS2
TSB27
TSB2(7:0)
0
TSB26
TSB25
TSB24
TSB23
TSB22
TSB21
TSB20
(A2)
Time Slot Bit Selection - HDLC Channel 2
Only bits selected by this register are used for HDLC channel 2 in
selected time slots. Time slot selection is done by setting the
appropriate bits in register TSS2. Bit selection is common to receive
and transmit direction. By default all bit positions within the selected
time slot are enabled.
TSB2x=0 to bit position x in selected time slot(s) is not used for
HDLC channel 2 reception and transmission.
TSB2x=1 to bit position x in selected time slot(s) is used for HDLC
channel 2 reception and transmission.
Time Slot Bit Select 3 (Read/Write)
Value after reset: FFH
7
TSBS3
TSB37
TSB3(7:0)
0
TSB36
TSB35
TSB34
TSB33
TSB32
TSB31
TSB30
A3)
Time Slot Bit Selection - HDLC Channel 3
Only bits selected by this register are used for HDLC channel 3 in
selected time slots. Time slot selection is done by setting the
appropriate bits in register TSS3. Bit selection is common to receive
and transmit direction. By default all bit positions within the selected
time slot are enabled.
TSB3x=0 to bit position x in selected time slot(s) is not used for
HDLC channel 3 reception and transmission.
TSB3x=1 to bit position x in selected time slot(s) is used for HDLC
channel 3 reception and transmission.
Data Sheet
404
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Time Slot Select 2 (Read/Write)
Value after reset: 00H
7
0
TSS2
TSS24
TSS2(4:0)
TSS23
TSS22
TSS21
TSS20
(A4)
Time Slot Selection Code - HDLC Channel 2
Defines the time slot used by HDLC channel 2.
00000 =No time slot selected
00001 =Time slot 1
...
11111 =Time slot 31
Note: Different HDLC channels must use different time slots.
Time Slot Select 3 (Read/Write)
Value after reset: 00H
7
0
TSS3
TSB3(4:0)
TSS34
TSS33
TSS32
TSS31
TSS30
(A5)
Time Slot Selection Code - HDLC Channel 3
Defines the time slot used by HDLC channel 3.
00000 =No time slot selected
00001 =Time slot 1
...
11111 =Time slot 31
Note: Different HDLC channels must use different time slots.
Data Sheet
405
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Test Pattern Control Register 0 (Read/Write)
Value after reset: 00H
7
TPC0
FRA
Data Sheet
0
FRA
(A8)
Framed/Unframed Selection
0=
PRBS is generated/monitored unframed.
Framing information is overwritten by the generator.
1=
PRBS is generated/monitored framed.
Time slot 0 is not overwritten by the generator and not observed
by the monitor.
406
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
10.3
T1/J1 Status Register Addresses
Table 67
T1/J1 Status Register Address Arrangement
Address
Register
Type Comment
Page
00
RFIFO
R
Receive FIFO
409
01
RFIFO
R
Receive FIFO
409
49
RBD
R
Receive Buffer Delay
409
4A
VSTR
R
Version Status Register
410
4B
RES
R
Receive Equalizer Status
410
4C
FRS0
R
Framer Receive Status 0
411
4D
FRS1
R
Framer Receive Status 1
413
4E
FRS2
R
Framer Receive Status 2
415
50
FECL
R
Framing Error Counter Low
416
51
FECH
R
Framing Error Counter High
416
52
CVCL
R
Code Violation Counter Low
417
53
CVCH
R
Code Violation Counter High
417
54
CECL
R
CRC Error Counter Low
418
55
CECH
R
CRC Error Counter High
418
56
EBCL
R
Errored Block Counter Low
419
57
EBCH
R
Errored Block Counter High
419
58
BECL
R
Bit Error Counter Low
420
59
BECH
R
Bit Error Counter High
420
5A
COEC
R
COFA Event Counter
421
5C
RDL1
R
Receive DL-Bit Register 1
422
5D
RDL2
R
Receive DL-Bit Register 2
422
5E
RDL3
R
Receive DL-Bit Register 3
423
62
RSP1
R
Receive Signaling Pointer 1
423
63
RSP2
R
Receive Signaling Pointer 2
423
64
SIS
R
Signaling Status Register
424
65
RSIS
R
Receive Signaling Status Register
425
66
RBCL
R
Receive Byte Control Low
427
67
RBCH
R
Receive Byte Control High
427
68
ISR0
R
Interrupt Status Register 0
428
Data Sheet
407
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Table 67
T1/J1 Status Register Address Arrangement (cont’d)
Address
Register
Type Comment
Page
69
ISR1
R
Interrupt Status Register 1
430
6A
ISR2
R
Interrupt Status Register 2
431
6B
ISR3
R
Interrupt Status Register 3
433
6C
ISR4
R
Interrupt Status Register 4
434
6D
ISR5
R
Interrupt Status Register 5
436
6E
GIS
R
Global Interrupt Status
437
70
RS1
R
Receive Signaling Register 1
438
71
RS2
R
Receive Signaling Register 2
438
72
RS3
R
Receive Signaling Register 3
438
73
RS4
R
Receive Signaling Register 4
438
74
RS5
R
Receive Signaling Register 5
438
75
RS6
R
Receive Signaling Register 6
438
76
RS7
R
Receive Signaling Register 7
438
77
RS8
R
Receive Signaling Register 8
438
78
RS9
R
Receive Signaling Register 9
438
79
RS10
R
Receive Signaling Register 10
438
7A
RS11
R
Receive Signaling Register 11
438
7B
RS12
R
Receive Signaling Register 12
438
90
RBC2
R
Receive Byte Count Register 2
439
91
RBC3
R
Receive Byte Count Register 3
439
98
SIS2
R
Signaling Status Register 2
439
99
RSIS2
R
Receive Signaling Status Register 2 440
9A
SIS3
R
Signaling Status Register 3
9B
RSIS3
R
Receive Signaling Status Register 3 443
9C
RFIFO2
R
Receive FIFO 2
445
9D
RFIFO2
R
Receive FIFO 2
445
9E
RFIFO3
R
Receive FIFO 3
445
9F
RFIFO3
R
Receive FIFO 3
445
EC
WID
R
Identification Register
445
Data Sheet
408
442
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
10.4
Detailed Description of T1/J1 Status Registers
Receive FIFO - HDLC Channel 1 (Read)
7
0
RFIFO
RF7
RF0
(00)
RFIFO
RF15
RF8
(01)
Reading data from RFIFO can be done in an 8-bit (byte) or 16-bit (word) access
depending on the selected bus interface mode. The LSB is received first from the serial
interface.
The size of the accessible part of RFIFO is determined by programming the bits
CCR1.RFT(1:0) (RFIFO threshold level). It can be reduced from 32 bytes (reset value)
down to 2 bytes (four values: 32, 16, 4, 2 bytes).
Data Transfer
Up to 32 bytes/16 words of received data can be read from the RFIFO following a RPF
or a RME interrupt.
RPF Interrupt: A fixed number of bytes/words to be read (32, 16, 4, 2 bytes). The
message is not yet complete.
RME Interrupt: The message is completely received. The number of valid bytes is
determined by reading the RBCL, RBCH registers.
RFIFO is released by issuing the RMC (Receive Message Complete) command.
Receive Buffer Delay (Read)
7
RBD
RBD(5:0)
0
RBD5
RBD4
RBD3
RBD2
RBD1
RBD0
(49)
Receive Elastic Buffer Delay
These bits informs the user about the current delay (in time slots)
through the receive elastic buffer. The delay is updated every 386 or
193 bits (SIC1.RBS(1:0)). Before reading this register the user has to
set bit DEC.DRBD in order to halt the current value of this register.
After reading RBD updating of this register is enabled. Not valid if the
receive buffer is bypassed.
000000 = Delay < 1 time slot
...
111111 = Delay > 63 time slots
Data Sheet
409
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Version Status Register (Read)
VSTR
7
0
VN7
VN0
VN(7:0)
(4A)
Version Number of Chip
00H =Version 1.2
Receive Equalizer Status (Read)
7
RES
EV(1:0)
EV1
0
EV0
RES4
RES3
RES2
RES1
RES0
(4B)
Equalizer Status Valid
These bits informs the user about the current state of the receive
equalization network. Only valid if LIM1.EQON is set.
00 = Equalizer status not valid, still adapting
01 = Equalizer status valid
10 = Equalizer status not valid
11 = Equalizer status valid but high noise floor
RES(4:0)
Receive Equalizer Status
The current line attenuation status in steps of about 1.4 dB are
displayed in these bits. Only valid if bits EV(1:0) = 01 and
LIM1.EQON = 1.
Accuracy: ± 2 digits, based on temperature influence and noise
amplitude variations.
00000 = Minimum attenuation: 0 dB
...
11001 = Maximum attenuation: -36 dB
Data Sheet
410
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Receive Status Register 0 (Read)
7
FRS0
LOS
LOS
0
AIS
LFA
RRA
LMFA
FSRF
(4C)
Loss-of-Signal (Red Alarm)
Detection:
This bit is set when the incoming signal has “no transitions“ (analog
interface) or logical zeros (digital interface) in a time interval of T
consecutive pulses, where T is programmable by PCD register:
Total account of consecutive pulses: 16 < T < 4096.
Analog interface: The receive signal level where “no transition” is
declared is defined by the programmed value of LIM1.RIL(2:0).
Recovery:
Analog interface: The bit is reset in short-haul mode when the
incoming signal has transitions with signal levels greater than the
programmed receive input level (LIM1.RIL(2:0)) for at least M pulse
periods defined by register PCR in the PCD time interval. In long-haul
mode additionally bit RES.6 must be set for at least 250 µs.
Digital interface: The bit is reset when the incoming data stream
contains at least M ones defined by register PCR in the PCD time
interval.
With the rising edge of this bit an interrupt status bit (ISR2.LOS) is set.
For additionally recovery conditions refer also to register LIM2.LOS1.
The bit is set during alarm simulation and reset if FRS2.ESC = 0, 3,
4, 6,7 and no alarm condition exists.
AIS
Alarm Indication Signal (Blue Alarm)
This bit is set when the conditions defined by bit FMR4.AIS3 are
detected. The flag stays active for at least one multiframe.
With the rising edge of this bit an interrupt status bit (ISR2.AIS) is set.
It is reset with the beginning of the next following multiframe if no
alarm condition is detected.
The bit is set during alarm simulation and reset if FRS2.ESC = 0, 3,
4, 7 and no alarm condition exists.
Data Sheet
411
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
LFA
Loss of Frame Alignment
The flag is set if pulseframe synchronization has been lost. The
conditions are specified by bit FMR4.SSC(1:0). Setting this bit causes
an interrupt (ISR2.LFA).
The flag is cleared when synchronization has been regained.
Additionally interrupt status ISR2.FAR is set with clearing this bit.
RRA
Receive Remote Alarm (Yellow Alarm)
The flag is set after detecting remote alarm (yellow alarm). Conditions
for setting/resetting are defined by bit RC0.RRAM.
With the rising edge of this bit an interrupt status bit ISR2.RA is set.
With the falling edge of this bit an interrupt status bit ISR2.RAR is set.
The bit is set during alarm simulation and reset if FRS2.ESC = 0, 3,
4,5,7 and no alarm condition exists.
LMFA
Loss Of Multiframe Alignment
Set in F12 or F72 format when 2 out of 4 (or 5 or 6) multiframe
alignment patterns are incorrect.
Additionally the interrupt status bit ISR2.LMFA is set.
Cleared after multiframe synchronization has been regained. With the
falling edge of this bit an interrupt status bit ISR2.MFAR is generated.
FSRF
Frame Search Restart Flag
Toggles when no framing candidate (pulse framing or multiframing) is
found and a new frame search is started.
Data Sheet
412
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Receive Status Register 1 (Read)
7
FRS1
EXZD
EXZD
0
PDEN
LLBDD
LLBAD
XLS
XLO
(4D)
Excessive Zeros Detected
Significant only if
(FMR2.EXZE = 1).
excessive
zeros
detection
is
enabled
Set after detecting of more than 7 (B8ZS code) or more than 15 (AMI
code) contiguous zeros in the received bit stream. This bit is cleared
on read.
PDEN
Pulse-Density Violation Detected
The pulse-density of the received data stream is below the
requirement defined by ANSI T1. 403 or more than 14 consecutive
zeros are detected. With the violation of the pulse-density this bit is
set and remains active until the pulse-density requirement is fulfilled
for 23 consecutive "1"-pulses.
Additionally an interrupt status ISR0.PDEN is generated with the
rising edge of PDEN.
LLBDD
Line Loop-Back Deactivation Signal Detected
This bit is set in case of the LLB deactivate signal is detected and then
received over a period of more than 33,16 ms with a bit error rate less
than 10-2. The bit remains set as long as the bit error rate does not
exceed 10-2.
If framing is aligned, the first bit position of any frame is not taken into
account for the error rate calculation.
Any change of this bit causes an LLBSC interrupt.
LLBAD
Line Loop-Back Activation Signal Detected/PRBS Status
Depending on bit LCR1.EPRM the source of this status bit changed.
LCR1.EPRM = 0: This bit is set in case of the LLB activate signal is
detected and then received over a period of more than 33,16 ms with
a bit error rate less than 10-2. The bit remains set as long as the bit
error rate does not exceed 10-2.
If framing is aligned, the first bit position of any frame is not taken into
account for the error rate calculation.
Any change of this bit causes an LLBSC interrupt.
Data Sheet
413
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
PRBS Status
LCR1.EPRM = 1: The current status of the PRBS synchronizer is
indicated in this bit. It is set high if the synchronous state is reached
even in the presence of a bit error rate of up to 10-3. A data stream
containing all zeros or all ones with/without framing bits is also a valid
pseudo-random binary sequence.
XLS
Transmit Line Short
Significant only if the ternary line interface is selected by
LIM1.DRS = 0.
XLO
Data Sheet
0=
Normal operation. No short is detected.
1=
The XL1 and XL2 are shortened for at least 3 pulses. As a
reaction of the short the pins XL1 and XL2 are automatically
forced into a high-impedance state if bit XPM2.DAXLT is reset.
After 128 consecutive pulse periods the outputs XL1/2 are
activated again and the internal transmit current limiter is
checked. If a short between XL1/2 is still further active the
outputs XL1/2 are in high-impedance state again. When the
short disappears pins XL1/2 are activated automatically and
this bit is reset. With any change of this bit an interrupt
ISR1.XLSC is generated. In case of XPM2.XLT is set this bit is
frozen.
Transmit Line Open
0=
Normal operation
1=
This bit is set if at least 32 consecutive zeros were sent on pins
XL1/XL2 or XDOP/XDON. This bit is reset with the first
transmitted pulse. With the rising edge of this bit an interrupt
ISR1.XLSC is set. In case of XPM2.XLT is set this bit is frozen.
414
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Framer Receive Status Register 2 (Read)
7
FRS2
0
ESC2
ESC(2:0)
ESC1
ESC0
(4E)
Error Simulation Counter
This three-bit counter is incremented by setting bit FMR0.SIM. The
state of the counter determines the function to be tested.
For complete checking of the alarm indications, eight simulation steps
are necessary (FRS2.ESC = 0 after a complete simulation).
Table 68
Alarm Simulation States
Tested Alarms ESC(2:0) =
0
1
2
3
4
5
6
LFA
×
×
LMFA
×
×
7
×
RRA (bit2 = 0)
×
RRA (S-bit frame 12)
×
RRA (DL-pattern)
×
LOS1)
×
×
×
EBC2) (F12,F72)
(×)
EBC2) (only ESF)
×
×
×
(×)
AIS1)
×
×
×
×
×
FEC2)
(×)
CVC
×
×
×
CEC (only ESF)
×
×
×
RSP
×
×
×
RSN
×
XSP
×
XSN
×
BEC1)
×
×
COEC
×
×
1)
only active during FMR0.SIM = 1
2)
FEC is counting +2 while EBC is counting +1 if the framer is in synchronous state; if asynchronous in state 2
but synchronous in state 6, counters are incremented during state 6
Data Sheet
415
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Some of these alarm indications are simulated only if the FALC56 is configured in the
appropriate mode. At simulation steps 0, 3, 4, and 7 pending status flags are reset
automatically and clearing of the error counters and interrupt status registers ISR(5:0)
should be done. Incrementing the simulation counter should not be done at time intervals
shorter than 1.5 ms (F4, F12, F72) or 3 ms (ESF). Otherwise, reactions of initiated
simulations might occur at later steps. Control bit FMR0.SIM has to be held stable at high
or low level for at least one receive clock period before changing it again.
Framing Error Counter (Read)
FECL
FECH
FE(15:0)
7
0
FE7
FE0
7
0
FE15
FE8
(50)
(51)
Framing Errors
This 16-bit counter is incremented when incorrect FT and FS-bits in
F4, F12 and F72 format or incorrect FAS-bits in ESF format are
received.
Framing errors are counted during synchronous state only (but even
if multiframe synchronous state is not reached yet). The error counter
does not roll over.
During alarm simulation, the counter is incremented twice.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DFEC has
to be set. With the rising edge of this bit updating the buffer is stopped
and the error counter is reset. Bit DEC.DFEC is automatically reset
with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
416
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Code Violation Counter (Read)
CVCL
CVCH
CV(15:0)
7
0
CV7
CV0
7
0
CV15
CV8
(52)
(53)
Code Violations
No function if NRZ or CMI code has been enabled.
If the B8ZS code (bit FMR0.RC(1:0) = 11) is selected, the 16-bit
counter is incremented by detecting violations which are not due to
zero substitution. If FMR2.EXZE is set, additionally excessive zero
strings (more than 7 contiguous zeros) are detected and counted.
If simple AMI coding is enabled (FMR0.RC0/1 = 10) all bipolar
violations are counted. If FMR2.EXZE is set, additionally excessive
zero strings (more than 15 contiguous zeros) are detected and
counted. The error counter does not roll over.
During alarm simulation, the counter is incremented continuously with
every second received bit.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCVC
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DCVC is
automatically reset with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
417
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
CRC Error Counter (Read)
CECL
CECH
CR(15:0)
7
0
CR7
CR0
7
0
CR15
CR8
(54)
(55)
CRC Errors
No function if CRC6 procedure or ESF format are disabled.
In ESF mode, the 16-bit counter is incremented when a multiframe
has been received with a CRC error. CRC errors are not counted
during asynchronous state. The error counter does not roll over.
During alarm simulation, the counter is incremented once per
multiframe.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCEC
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DCEC is
automatically reset with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
418
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Errored Block Counter (Read)
7
0
EBC7
EBC0
7
0
EBC15
EBC8
EBCL
EBCH
EBC(15:0)
(56)
(57)
Errored Block Counter
In ESF format this 16-bit counter is incremented once per multiframe
if a multiframe has been received with a CRC error or an errored
frame alignment has been detected. CRC and framing errors are not
counted during asynchronous state. The error counter does not roll
over.
In F4/12/72 format an errored block contain 4/12 or 72 frames.
Incrementing is done once per multiframe if framing errors has been
detected.
During alarm simulation, the counter is incremented in ESF format
once per multiframe and in F4/12/72 format only one time.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DEBC
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DEBC is automatically
reset with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
419
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Bit Error Counter (Read)
7
0
BEC7
BEC0
7
0
BEC15
BEC8
BECL
BECH
BEC(15:0)
(58)
(59)
Bit Error Counter
If the PRBS monitor is enabled by LCR1.EPRM = 1 this 16-bit counter
is incremented with every received PRBS bit error in the PRBS
synchronous state FRS1.LLBAD = 1. The error counter does not roll
over.
During alarm simulation, the counter is incremented continuously with
every second received bit.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the PRBS bit error counter bit
DEC.DBEC has to be set. With the rising edge of this bit updating the
buffer is stopped and the error counter is reset. Bit DEC.DBEC is
automatically reset with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
420
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
COFA Event Counter (Read)
7
COEC
COE(7:2)
0
COE7
COE2
COE1
COE0
(5A)
Multiframe Counter
If GCR.ECMC = 1 this 6 bit counter increments with each multiframe
period in the asynchronous state FRS0.LFA/LMFA = 1. The error
counter does not roll over.
COE(1:0)
Change of Frame Alignment Counter
If GCR.ECMC = 1 this 2 bit counter increments with each detected
change of frame/multiframe alignment. The error counter does not roll
over.
During alarm simulation, the counter is incremented once per
multiframe.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the event counter bit DEC.DCOEC
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DCOEC is
automatically reset with reading the error counter high byte on
address 5BH. Data read on 5BH is not defined.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
Data Sheet
421
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive DL-Bit Register 1 (Read)
7
RDL1
RDL17
RDL1(7:0)
0
RDL16
RDL15
RDL14
RDL13
RDL12
RDL11
RDL10
(5C)
Receive DL-Bit
Only valid if F12, F24 or F72 format is enabled.
The received FS/DL-Bits are shifted into this register. RDL10 is
received in frame 1 and RDL17 in frame 15, if F24 format is enabled.
RDL10 is received in frame 26 and RDL17 in frame 40, if F72 format
is enabled.
In F12 format the FS-Bits of a complete multiframe is stored in this
register. RDL10 is received in frame 2 and RDL15 in frame 12.
This register is updated with every receive multiframe begin interrupt
ISR0.RMB.
Receive DL-Bit Register 2 (Read)
7
RDL2
RDL27
RDL2(7:0)
0
RDL26
RDL25
RDL24
RDL23
RDL22
RDL21
RDL20
(5D)
Receive DL-Bit
Only valid if F24 or F72 format is enabled.
The received DL-Bits are shifted into this register. RDL20 is received
in frame 17 and RDL23 in frame 23, if F24 format is enabled. RDL20
is received in frame 42 and RDL27 in frame 56, if F72 format is
enabled.
This register is updated with every receive multiframe begin interrupt
ISR0.RMB.
Data Sheet
422
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive DL-Bit Register 3 (Read)
7
RDL3
RDL37
RDL3(7:0)
0
RDL36
RDL35
RDL34
RDL33
RDL32
RDL31
RDL30
(5E)
Receive DL-Bit
Only valid if F72 format is enabled.
The received DL-Bits are shifted into this register. RDL30 is received
in frame 58 and RDL37 in frame 72, if F72 format is enabled.
This register is updated with every receive multiframe begin interrupt
ISR0.RMB.
Receive Signaling Pointer 1 (Read)
Value after reset: 00H
7
RSP1
RS8C
RS(8:1)C
0
RS7C
RS6C
RS5C
RS4C
RS3C
RS2C
RS1C
(62)
Receive Signaling Register RS(8:1) Changed
A one in each bit position indicates that the received signaling data in
the corresponding RS(8:1) registers are updated. Bit RS1C is the
pointer for register RS1, while RS8C points to RS8.
Receive Signaling Pointer 2 (Read)
Value after reset: 00H
7
RSP2
RS(12:0)C
0
RS12C
RS11C
RS10C
RS9C
(63)
Receive Signaling Register RS(12:9) Changed
A one in each bit position indicates that the received signaling data in
the corresponding RS(12:9) registers are updated. Bit RS9C is the
pointer for register RS9, while RS12C points to RS12
Data Sheet
423
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Signaling Status Register (Read)
7
SIS
XDOV
XDOV
0
XFW
XREP
IVB
RLI
CEC
SFS
BOM
(64)
Transmit Data Overflow - HDLC Channel 1
More than 32 bytes have been written to the XFIFO.
This bit is reset
– by a transmitter reset command XRES or
– when all bytes in the accessible half of the XFIFO have been moved
in the inaccessible half.
XFW
Transmit FIFO Write Enable - HDLC Channel 1
Data can be written to the XFIFO.
XREP
Transmission Repeat - HDLC Channel 1
Status indication of CMDR.XREP.
IVB
RLI
Invalid BOM Frame Received - HDLC Channel 1
0=
Valid BOM frame (11111111, 0xxxxxx0) received.
1=
Invalid BOM frame received.
Receive Line Inactive - HDLC Channel 1
Neither flags as interframe time fill nor frames are received in the
signaling time slot.
CEC
Command Executing
0=
No command is currently executed, the CMDR register can be
written to.
1=
A command (written previously to CMDR) is currently executed,
no further command can be temporarily written in CMDR
register.
Note: CEC is active at most 2.5 periods of the current system data
rate.
SFS
Data Sheet
Status Freeze Signaling
0=
Freeze signaling status inactive.
1=
Freeze signaling status active.
424
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
BOM
Bit Oriented Message - HDLC Channel 1
Significant only in ESF frame format and auto switching mode is
enabled.
0=
HDLC mode
1=
BOM mode
Receive Signaling Status Register (Read)
7
RSIS
VFR
0
RDO
CRC16
RAB
HA1
HA0
HFR
LA
(65)
RSIS relates to the last received HDLC or BOM frame; it is copied into RFIFO when endof-frame is recognized (last byte of each stored frame).
VFR
Valid Frame - HDLC Channel 1
Determines whether a valid frame has been received.
1=
Valid
0=
Invalid
An invalid frame is either
– a frame which is not an integer number of 8 bits (n×8 bits) in length
(e.g. 25 bits), or
– a frame which is too short taking into account the operation mode
selected by MODE (MDS(2:0)) and the selection of receive CRC
on/off (CCR2.RCRC) as follows:
• MDS(2:0) = 011 (16 bit Address),
RCRC = 0: 4 bytes; RCRC = 1: 3 or 4 bytes
• MDS(2:0) = 010 (8 bit Address),
RCRC = 0: 3 bytes; RCRC = 1: 2 or 3 bytes
Note: Shorter frames are not reported.
RDO
Receive Data Overflow - HDLC Channel 1
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR1.RDO/IMR1.RDO).
CRC16
Data Sheet
CRC16 Compare/Check - HDLC Channel 1
0=
CRC check failed; received frame contains errors.
1=
CRC check o.k.; received frame is error-free.
425
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RAB
Receive Message Aborted - HDLC Channel 1
This bit is set in SS7 mode, if the maximum number of octets (272+7)
is exceeded. The received frame was aborted from the transmitting
station. According to the HDLC protocol, this frame must be discarded
by the receiver station.
HA1, HA0
High Byte Address Compare - HDLC Channel 1
Significant only if 2-byte address mode or SS7 mode has been
selected.
In operating modes which provide high byte address recognition, the
FALC56 compares the high byte of a 2-byte address with the contents
of two individually programmable registers (RAH1, RAH2) and the
fixed values FEH and FCH (broadcast address).
Depending on the result of this comparison, the following bit
combinations are possible (SS7 support not active):
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R = 0 (bit 1)
11 = RAH1 has been recognized C/R = 1 (bit 1)
Note: If RAH1, RAH2 contain identical values, a match is indicated
by "10" or "11".
If Signaling System 7 support is activated (see MODE register), the
bit functions are defined as follows:
00 = not valid
01 = Fill In signaling unit (FISU) detected
10 = Link status signaling unit (LSSU) detected
11 = Message signaling unit (MSU) detected
HFR
HDLC Frame Format - HDLC Channel 1
0=
A BOM frame was received.
1=
A HDLC frame was received.
Note: Bits RSIS.(7:2) and RSIS.0 are not valid with a BOM frame. This
means, if HFR = 0, all other bits of RSIS have to be ignored
Not valid in SS7 mode. Bit HFR has to be ignored, if SS7 mode
is selected.
Data Sheet
426
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
LA
Low Byte Address Compare - HDLC Channel 1
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared to two registers. (RAL1,
RAL2).
0=
1=
RAL2 has been recognized
RAL1 has been recognized
Note: Not valid in SS7 mode. Bit LA has to be ignored, if SS7 mode is
selected.
Receive Byte Count Low - HDLC Channel 1 (Read)
RBCL
7
0
RBC7
RBC0
(66)
Together with RBCH, bits RBC(11:8), indicates the length of a received frame (1 to 4095
bytes). Bits RBC(4:0) indicate the number of valid bytes currently in RFIFO. These
registers must be read by the CPU following a RME interrupt.
Received Byte Count High - HDLC Channel 1 (Read)
Value after reset: 000xxxxx
7
RBCH
OV
0
OV
RBC11
RBC10
RBC9
RBC8
(67)
Counter Overflow - HDLC Channel 1
More than 4095 bytes received.
RBC(11:8)
Receive Byte Count - HDLC Channel 1 (most significant bits)
Together with RBCL (bits RBC7...0) indicates the length of the
received frame.
Data Sheet
427
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Interrupt Status Register 0 (Read)
Value after reset: 00H
7
ISR0
RME
0
RFS/BIV
ISF
RMB
RSC
CRC6
PDEN
RPF
(68)
All bits are reset when ISR0 is read.
If bit GCR.VIS is set, interrupt statuses in ISR0 are flagged although they are masked by
register IMR0. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
RME
Receive Message End - HDLC Channel 1
One complete message of length less than 32 bytes, or the last part
of a frame at least 32 bytes long is stored in the receive FIFO,
including the status byte.
The complete message length can be determined reading the RBCH,
RBCL registers, the number of bytes currently stored in RFIFO is
given by RBC(4:0). Additional information is available in the RSIS
register.
RFS/BIV
Receive Frame Start - HDLC Channel 1
This is an early receiver interrupt activated after the start of a valid
frame has been detected, i.e. after an address match (in operation
modes providing address recognition), or after the opening flag
(transparent mode 0) is detected, delayed by two bytes. After a RFS
interrupt, the contents of RAL1and RSIS.3-1 are valid and can be
read by the CPU.
BOM Frame Invalid - HDLC Channel 1
Only valid if CCR2.RBFE is set.
When the BOM receiver left the valid BOM status (detecting 7 out of
10 equal BOM frames) this interrupt is generated.
ISF
Incorrect Sync Format - HDLC Channel 1
The FALC56 did not detect eight consecutive ones within 32 bits in
BOM mode. Only valid if BOM receiver has been activated.
RMB
Receive Multiframe Begin
This bit is set with the beginning of a received multiframe of the
receive line timing.
Data Sheet
428
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RSC
Received Signaling Information Changed
This interrupt bit is set during each multiframe in which signaling
information on at least one channel changes its value from the
previous multiframe. This interrupt only occurs in the synchronous
state. The registers RS(12:1) should be read within the next 3 ms
otherwise the contents is lost.
CRC6
PDEN
Receive CRC6 Error
0=
No CRC6 error occurs.
1=
The CRC6 check of the last received multiframe failed.
Pulse-Density Violation
The pulse-density violation of the received data stream defined by
ANSI T1. 403 is violated. More than 14 consecutive zeros or less than
N ones in each and every time window of 8×(N+1) data bits (N = 23)
are detected. If GCR.SCI is set high this interrupt status bit is
activated with every change of state of FRS1.PDEN.
RPF
Receive Pool Full - HDLC Channel 1
32 bytes of a frame have arrived in the receive FIFO. The frame is not
yet received completely.
Data Sheet
429
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Interrupt Status Register 1 (Read)
7
ISR1
CASE
0
RDO
ALLS
XDU
XMB
SUEX
XLSC
XPR
(69)
All bits are reset when ISR1 is read.
If bit GCR.VIS is set, interrupt statuses in ISR1 are flagged although they are masked by
register IMR1. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
CASE
Transmit CAS Register Empty
In ESF format this bit is set with the beginning of a transmitted
multiframe related to the internal transmitter timing. In F12 and F72
format this interrupt occurs every 24 frames to inform the user that
new bit robbing data may be written to the XS(12:1) registers. This
interrupt is generated only if the serial signaling access on the system
highway is not enabled.
RDO
Receive Data Overflow - HDLC Channel 1
This interrupt status indicates that the CPU did not respond fast
enough to an RPF or RME interrupt and that data in RFIFO has been
lost. Even when this interrupt status is generated, the frame continues
to be received when space in the RFIFO is available again.
Note: Whereas the bit RSIS.RDO in the frame status byte indicates
whether an overflow occurred when receiving the frame
currently accessed in the RFIFO, the ISR1.RDO interrupt status
is generated as soon as an overflow occurs and does not
necessarily pertain to the frame currently accessed by the
processor.
ALLS
All Sent - HDLC Channel 1
This bit is set if the last bit of the current frame has been sent
completely and XFIFO is empty. This bit is valid in HDLC mode only.
XDU
Transmit Data Underrun - HDLC Channel 1
Transmitted frame was terminated with an abort sequence because
no data was available for transmission in XFIFO and no XME was
issued.
Note: Transmitter and XFIFO are reset and deactivated if this
condition occurs. They are reactivated not before this interrupt
status register has been read. Thus, XDU should not be
masked by register IMR1.
Data Sheet
430
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XMB
Transmit Multiframe Begin
This bit is set with the beginning of a transmitted multiframe related to
the internal transmit line interface timing.
SUEX
Signaling Unit Error Threshold Exceeded - HDLC Channel 1
Masks the indication by interrupt that the selected error threshold for
SS7 signaling units has been exceeded.
0=
Signaling unit error count below selected threshold
1=
Signaling unit error count exceeded selected threshold
Note:
XLSC
SUEX is only valid, if SS7 mode is selected.
If SUEX is caused by an aborted/invalid frame, the interrupt
will be issued regularly until a valid frame is received (e.g. a
FISU).
Transmit Line Status Change
XLSC is set with the rising edge of the bit FRS1.XLO or with any
change of bit FRS1.XLS.
The actual status of the transmit line monitor can be read from the
FRS1.XLS and FRS1.XLO.
XPR
Transmit Pool Ready - HDLC Channel 1
A data block of up to 32 bytes can be written to the transmit FIFO.
XPR enables the fastest access to XFIFO. It has to be used for
transmission of long frames, back-to-back frames or frames with
shared flags.
Interrupt Status Register 2 (Read)
7
ISR2
FAR
0
LFA
MFAR
LMFA
AIS
LOS
RAR
RA
(6A)
All bits are reset when ISR2 is read.
If bit GCR.VIS is set, interrupt statuses in ISR2 are flagged although they are masked by
register IMR2. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
FAR
Frame Alignment Recovery
The framer has reached synchronization. Set with the falling edge of
bit FRS0.LFA.
It is set also after alarm simulation is finished and the receiver is still
synchronous.
Data Sheet
431
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
LFA
Loss of Frame Alignment
The framer has lost synchronization and bit FRS0.LFA is set.
It is set during alarm simulation.
MFAR
Multiframe Alignment Recovery
Set when the framer has reached multiframe alignment in F12 or F72
format. With the negative transition of bit FRS0.LMFA this bit is set. It
is set during alarm simulation.
LMFA
Loss of Multiframe Alignment
Set when the framer has lost the multiframe alignment in F12 or F72
format. With the positive transition of bit FRS0.LMFA this bit is set. It
is set during alarm simulation.
AIS
Alarm Indication Signal (Blue Alarm)
This bit is set when an alarm indication signal is detected and bit
FRS0.AIS is set. If GCR.SCI is set high this interrupt status bit is
activated with every change of state of FRS0.AIS.
It is set during alarm simulation.
LOS
Loss-of-Signal (Red Alarm)
This bit is set when a loss-of-signal alarm is detected in the received
data stream and FRS0.LOS is set. If GCR.SCI is set high this interrupt
status bit is activated with every change of state of FRS0.LOS.
It is set during alarm simulation.
RAR
Remote Alarm Recovery
Set if a remote alarm (yellow alarm) is cleared and bit FRS0.RRA is
reset. It is set also after alarm simulation is finished and no remote
alarm is detected.
RA
Remote Alarm
A remote alarm (yellow alarm) is detected. Set with the rising edge of
bit FRS0.RRA. It is set during alarm simulation.
Data Sheet
432
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Interrupt Status Register 3 (Read)
7
ISR3
ES
0
SEC
LLBSC
RSN
RSP
(6B)
All bits are reset when ISR3 is read.
If bit GCR.VIS is set, interrupt statuses in ISR3 are flagged although they are masked by
register IMR3. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
ES
Errored Second
This bit is set if at least one enabled interrupt source by ESM is set
during the time interval of one second. Interrupt sources of ESM
register:
LFA
FER
CER
AIS
LOS
CVE
SLIP
SEC
= Loss of frame alignment detected
= Framing error received
= CRC error received
= Alarm indication signal (blue alarm)
= Loss-of-signal (red alarm)
= Code violation detected
= Transmit slip or receive slip positive/negative detected
Second Timer
The internal one-second timer has expired. The timer is derived from
clock RCLK.
LLBSC
Line Loop-Back Status Change/PRBS Status Change
Depending on bit LCR1.EPRM the source of this interrupt status
changed:
LCR1.EPRM = 0: This bit is set, if the LLB activate signal or the LLB
deactivate signal is detected over a period of 33,16 ms with a bit error
rate less than 10-2.
The LLBSC bit is also set, if the current detection status is left, i.e., if
the bit error rate exceeds 10-2.
The actual detection status can be read from the FRS1.LLBAD and
FRS1.LLBDD, respectively.
PRBS Status Change
LCR1.EPRM = 1: With any change of state of the PRBS synchronizer
this bit is set. The current status of the PRBS synchronizer is
indicated in FRS1.LLBAD.
Data Sheet
433
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RSN
Receive Slip Negative
The frequency of the receive route clock is greater than the frequency
of the receive system interface working clock based on 1.544 MHz. A
frame is skipped. It is set during alarm simulation.
RSP
Receive Slip Positive
The frequency of the receive route clock is less than the frequency of
the receive system interface working clock based on 1.544 MHz. A
frame is repeated. It is set during alarm simulation.
Interrupt Status Register 4 (Read)
7
ISR4
XSP
0
XSN
RME2
RFS2
RDO2
ALLS2
XDU2
RPF2
(6C)
All bits are reset when ISR4 is read.
If bit GCR.VIS is set, interrupt statuses in ISR4 are flagged although they are masked by
register IMR4. However, these masked interrupt statuses neither generate a signal on
INT, nor are visible in register GIS.
XSP
Transmit Slip Positive
The frequency of the transmit clock is less than the frequency of the
transmit system interface working clock based on 1.544 MHz. A frame
is repeated. After a slip has performed writing of register XC1 is not
necessary.
XSN
Transmit Slip Negative
The frequency of the transmit clock is greater than the frequency of
the transmit system interface working clock based on 1.544 MHz. A
frame is skipped. After a slip has performed writing of register XC1 is
not necessary.
RME2
Receive Message End - HDLC Channel 2
One complete message of length less than 32 bytes, or the last part
of a frame at least 32 bytes long is stored in the receive FIFO2,
including the status byte.
The complete message length can be determined reading register
RBC2, the number of bytes currently stored in RFIFO2 is given by
RBC2(6:0). Additional information is available in register RSIS2.
Data Sheet
434
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RFS2
Receive Frame Start - HDLC Channel 2
This is an early receiver interrupt activated after the start of a valid
frame has been detected, i.e. after an address match (in operation
modes providing address recognition), or after the opening flag
(transparent mode 0) is detected, delayed by two bytes. After an
RFS2 interrupt, the contents of
• RAL1
• RSIS2 bits 3 to 1
are valid and can be read by the CPU.
RDO2
Receive Data Overflow - HDLC Channel 2
This interrupt status indicates that the CPU did not respond fast
enough to an RPF2 or RME2 interrupt and that data in RFIFO2 has
been lost. Even when this interrupt status is generated, the frame
continues to be received when space in the RFIFO2 is available
again.
Note: Whereas the bit RSIS2.RDO2 in the frame status byte
indicates whether an overflow occurred when receiving the
frame currently accessed in the RFIFO2, the ISR4.RDO2
interrupt status is generated as soon as an overflow occurs
and does not necessarily pertain to the frame currently
accessed by the processor.
ALLS2
All Sent - HDLC Channel 2
This bit is set if the last bit of the current frame has been sent
completely and XFIFO2 is empty. This bit is valid in HDLC mode only.
XDU2
Transmit Data Underrun - HDLC Channel 2
Transmitted frame was terminated with an abort sequence because
no data was available for transmission in XFIFO2 and no XME2 was
issued.
Note: Transmitter and XFIFO2 are reset and deactivated if this
condition occurs. They are reactivated not before this interrupt
status register has been read. Thus, XDU2 should not be
masked via register IMR4.
RPF2
Receive Pool Full - HDLC Channel 2
32 bytes of a frame have arrived in the receive FIFO2. The frame is
not yet completely received.
Data Sheet
435
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Interrupt Status Register 5 (Read)
7
ISR5
XPR2
0
XPR3
RME3
RFS3
RDO3
ALLS3
XDU3
RPF3
(6D)
All bits are reset when ISR5 is read.
If bit GCR.VIS is set, interrupt statuses in ISR5 are flagged although they are masked
via register IMR5. However, these masked interrupt statuses neither generate a signal
on INT, nor are visible in register GIS.
XPR2
Transmit Pool Ready - HDLC Channel 2
A data block of up to 32 bytes can be written to the transmit FIFO2.
XPR2 enables the fastest access to XFIFO2. It has to be used for
transmission of long frames, back-to-back frames or frames with
shared flags.
XPR3
Transmit Pool Ready - HDLC Channel 3
A data block of up to 32 bytes can be written to the transmit FIFO3.
XPR3 enables the fastest access to XFIFO3. It has to be used for
transmission of long frames, back-to-back frames or frames with
shared flags.
RME3
Receive Message End - HDLC Channel 3
One complete message of length less than 32 bytes, or the last part
of a frame at least 32 bytes long is stored in the receive FIFO3,
including the status byte.
The complete message length can be determined reading register
RBC3, the number of bytes currently stored in RFIFO3 is given by
RBC3(6:0). Additional information is available in register RSIS3.
RFS3
Receive Frame Start - HDLC Channel 3
This is an early receiver interrupt activated after the start of a valid
frame has been detected, i.e. after an address match (in operation
modes providing address recognition), or after the opening flag
(transparent mode 0) is detected, delayed by two bytes. After an
RFS2 interrupt, the contents of
• RAL1
• RSIS3 bits 3 to 1
are valid and can be read by the CPU.
Data Sheet
436
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
RDO3
Receive Data Overflow - HDLC Channel 3
This interrupt status indicates that the CPU did not respond fast
enough to an RPF3 or RME3 interrupt and that data in RFIFO3 has
been lost. Even when this interrupt status is generated, the frame
continues to be received when space in the RFIFO3 is available
again.
Note: Whereas the bit RSIS3.RDO3 in the frame status byte
indicates whether an overflow occurred when receiving the
frame currently accessed in the RFIFO3, the ISR5.RDO3
interrupt status is generated as soon as an overflow occurs
and does not necessarily pertain to the frame currently
accessed by the processor.
ALLS3
All Sent - HDLC Channel 3
This bit is set if the last bit of the current frame has been sent
completely and XFIFO3 is empty. This bit is valid in HDLC mode only.
XDU3
Transmit Data Underrun - HDLC Channel 3
Transmitted frame was terminated with an abort sequence because
no data was available for transmission in XFIFO3 and no XME3 was
issued.
Note: Transmitter and XFIFO3 are reset and deactivated if this
condition occurs. They are reactivated not before this interrupt
status register has been read. Thus, XDU3 should not be
masked via register IMR5.
RPF3
Receive Pool Full - HDLC Channel 3
32 bytes of a frame have arrived in the receive FIFO3. The frame is
not yet completely received.
Global Interrupt Status Register (Read)
Value after reset: 00H
7
GIS
0
ISR5
ISR4
ISR3
ISR2
ISR1
ISR0
(6E)
This status register points to pending interrupts sourced by ISR(5:0).
Data Sheet
437
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Signaling Register (Read)
Value after reset: not defined
Table 69
Receive Signaling Registers (T1/J1)
7
0
RS1
A1
B1
C1/A2
D1/B2
A2/A3
B2/B3
C2/A4
D2/B4
(70)
RS2
A3/A5
B3/B5
C3/A6
D3/B6
A4/A7
B4/B7
C4/A8
D4/B8
(71)
RS3
A5/A9
B5/B9
C5/A10
D5/B10
A6/A11
B6/B11
C6/A12
D6/B12
(72)
RS4
A7/A13
B7/B13
C7/A14
D7/B14
A8/A15
B8/B15
C8/A16
D8/B16
(73)
RS5
A9/A17
B9/B17
C9/A18
D9/B18
A10/A19 B10/B19 C10/A20 D10/B20
(74)
RS6
A11/A21 B11/B21 C11/A22 D11/B22 A12/A23 B12/B23 C12/A24 D12/B24
(75)
RS7
A13/A1
B13/B1
C13/A2
D13/B2
A14/A3
B14/B3
C14/A4
D14/B4
(76)
RS8
A15/A5
B15/B5
C15/A6
D15/B6
A16/A7
B16/B7
C16/A8
D16/B8
(77)
RS9
A17/A9
B17/B9
C17/A10 D17/B10 A18/A11 B18/B11 C18/A12 D18/B12
(78)
RS10
A19/A13 B19/B13 C19/A14 D19/B14 A20/A15 B20/B15 C20/A16 D20/B16
(79)
RS11
A21/A17 B21/B17 C21/A18 D21/B18 A22/A19 B22/B19 C22/A20 D22/B20
(7A)
RS12
A23/A21 B23/B21 C23/A22 D23/B22 A24/A23 B24/B23 C24/A24 D24/B24
(7B)
Receive Signaling Register 1 to 12
Each register contains the received bit robbing information for 8 DS0 channels. The
received robbed bit signaling information of a complete ESF multiframe is compared to
the previously received one. In F12/72 frame format the received signaling information
of every 24 frames is compared to the previously received 24 frames. If the contents
changed a Receive Signaling Changed interrupt ISR0.RSC is generated and informs the
user that a new multiframe has to be read within the next 3 ms. Received data is stored
in RS(12:1) registers. The RS1.7 is received in channel 1 frame 1 and RS12.0 in channel
24 frame 24 (ESF).
If requests for reading the RS(12:1) registers are ignored, received data might get lost.
Additionally a receive signaling data change pointer indicates an update of register
RS(12:1). Refer also to register RSP(2:1).
Access to RS(12:1) registers is only valid if the serial receive signaling access on the
system highway is disabled.
Data Sheet
438
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Byte Count Register 2 (Read)
Value after reset: 00H
7
RBC2
OV2
OV2
0
RBC26
RBC25
RBC24
RBC23
RBC22
RBC21
RBC20
(90)
Counter Overflow - HDLC Channel 2
RBC2(6:0)
0=
Less than or equal to 128 bytes received
1=
More than 128 bytes received
Receive Byte Count - HDLC Channel 2
Indicates the length of a received frame.
Receive Byte Count Register 3 (Read)
Value after reset: 00H
7
RBC3
OV3
OV3
0
RBC36
RBC35
RBC34
RBC33
RBC32
RBC31
RBC30
(91)
Counter Overflow - HDLC Channel 3
RBC3(6:0)
0=
Less than or equal to 128 bytes received
1=
More than 128 bytes received
Receive Byte Count - HDLC Channel 3
Indicates the length of a received frame.
Signaling Status Register 2 (Read)
Value after reset: 00H
7
SIS2
XDOV2
XDOV2
0
XFW2
XREP2
RLI2
CEC2
(98)
Transmit Data Overflow - HDLC Channel 2
More than 32 bytes have been written to the XFIFO2.
This bit is reset
– by a transmitter reset command XRES or
– when all bytes in the accessible half of the XFIFO2 have been
moved in the inaccessible half.
Data Sheet
439
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
XFW2
Transmit FIFO Write Enable - HDLC Channel 2
Data can be written to the XFIFO2.
XREP2
Transmission Repeat - HDLC Channel 2
Status indication of CMDR2.XREP2.
RLI2
Receive Line Inactive - HDLC Channel 2
Neither flags as interframe time fill nor frames are received via the
signaling time slot.
CEC2
Command Executing - HDLC Channel 2
0=
No command is currently executed, the CMDR3 register can be
written to.
1=
A command (written previously to CMDR3) is currently
executed, no further command can be temporarily written in
CMDR3 register.
Note: CEC2 will be active up to 2.5 periods of the current system data
rate.
Receive Signaling Status Register 2 (Read)
Value after reset: 00H
7
RSIS2
VFR2
0
RDO2
CRC162
RAB2
HA12
HA02
LA2
(99)
RSIS2 relates to the last received HDLC channel 2 frame; it is copied into RFIFO2 when
end-of-frame is recognized (last byte of each stored frame).
VFR2
Valid Frame - HDLC Channel 2
Determines whether a valid frame has been received.
1=
Valid
0=
Invalid
An invalid frame is either
– a frame which is not an integer number of 8 bits (n × 8 bits) in length
(e.g. 25 bits), or
– a frame which is too short taking into account the operation mode
selected via MODE2 (MDS2(2:0)) and the selection of receive CRC
ON/OFF (CCR3.RCRC2) as follows:
• MDS2(2:0) = 011 (16 bit Address),
RCRC2=0 : 4 bytes; RCRC2=1 : 3 or 4 bytes
Data Sheet
440
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
• MDS2(2:0) = 010 (8 bit Address),
RCRC2=0 : 3 bytes; RCRC2=1 : 2 or 3 bytes
Note: Shorter frames are not reported.
RDO2
Receive Data Overflow - HDLC Channel 2
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR4.RDO2/IMR4.RDO2).
CRC162
RAB2
CRC16 Compare/Check - HDLC Channel 2
0=
CRC check failed; received frame contains errors.
1=
CRC check o.k.; received frame is error-free.
Receive Message Aborted - HDLC Channel 2
This bit is set, if more than 5 contiguous 1-bits are detected.
HA12, HA02
High Byte Address Compare - HDLC Channel 2
Significant only if 2-byte address mode is selected.
In operating modes which provide high byte address recognition, the
FALC® compares the high byte of a 2-byte address with the contents
of two individually programmable registers (RAH1, RAH2) and the
fixed values FEH and FCH (broadcast address).
Depending on the result of this comparison, the following bit
combinations are possible:
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R=0 (bit 1)
11 = RAH1 has been recognized C/R=1 (bit 1)
Note: If RAH1, RAH2 contain identical values, a match is indicated by
"10" or "11".
Data Sheet
441
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
LA2
Low Byte Address Compare - HDLC Channel 2
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared with two registers. (RAL1,
RAL2).
0=
RAL2 has been recognized
1=
RAL1 has been recognized
Signaling Status Register 3 (Read)
Value after reset: 00H
7
SIS3
XDOV3
XDOV3
0
XFW3
XREP3
RLI3
CEC3
(9A)
Transmit Data Overflow - HDLC Channel 3
More than 32 bytes have been written to the XFIFO3.
This bit is reset
– by a transmitter reset command XRES or
– when all bytes in the accessible half of the XFIFO3 have been
moved in the inaccessible half.
XFW3
Transmit FIFO Write Enable - HDLC Channel 3
Data can be written to the XFIFO3.
XREP3
Transmission Repeat - HDLC Channel 3
Status indication of CMDR3.XREP3.
RLI3
Receive Line Inactive - HDLC Channel 3
Neither flags as interframe time fill nor frames are received via the
signaling time slot.
CEC3
Command Executing - HDLC Channel 3
0 = No command is currently executed, the CMDR4 register can be
written to.
1 = A command (written previously to CMDR4) is currently
executed, no further command can be temporarily written in CMDR4
register.
Note: CEC3 will be active at most 2.5 periods of the current system
data rate.
Data Sheet
442
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive Signaling Status Register 3 (Read)
Value after reset: 00H
7
RSIS3
VFR3
0
RDO3
CRC163
RAB3
HA13
HA03
LA3
(9B)
RSIS3 relates to the last received HDLC channel 3 frame; it is copied into RFIFO3 when
end-of-frame is recognized (last byte of each stored frame).
VFR3
Valid Frame - HDLC Channel 3
Determines whether a valid frame has been received.
1=
Valid
0=
Invalid
An invalid frame is either
– a frame which is not an integer number of 8 bits (n×8 bits) in length
(e.g. 25 bits), or
– a frame which is too short taking into account the operation mode
selected via MODE3 (MDS3(2:0)) and the selection of receive CRC
ON/OFF (CCR4.RCRC3) as follows:
• MDS3(2:0)=011 (16 bit Address),
RCRC3=0: 4 bytes; RCRC3=1: 3 or 4 bytes
• MDS3(2:0)=010 (8 bit Address),
RCRC3=0: 3 bytes; RCRC3=1: 2 or 3 bytes
Note: Shorter frames are not reported.
RDO3
Receive Data Overflow - HDLC Channel 3
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR5.RDO3/IMR5.RDO3).
CRC163
RAB3
CRC16 Compare/Check - HDLC Channel 3
0=
CRC check failed; received frame contains errors.
1=
CRC check o.k.; received frame is error-free.
Receive Message Aborted - HDLC Channel 3
This bit is set, if more than 5 contiguous 1-bits are detected.
Data Sheet
443
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
HA13, HA03
High Byte Address Compare - HDLC Channel 3
Significant only if 2-byte address mode is selected.
In operating modes which provide high byte address recognition, the
FALC® compares the high byte of a 2-byte address with the contents
of two individually programmable registers (RAH1, RAH2) and the
fixed values FEH and FCH (broadcast address).
Depending on the result of this comparison, the following bit
combinations are possible:
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R=0 (bit 1)
11 = RAH1 has been recognized C/R=1 (bit 1)
Note:If RAH1, RAH2 contain identical values, a match is indicated by
"10" or "11".
LA3
Low Byte Address Compare - HDLC Channel 3
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared with two registers. (RAL1,
RAL2).
0=
1=
Data Sheet
RAL2 has been recognized
RAL1 has been recognized
444
2002-08-27
FALC56 V1.2
PEB 2256
T1/J1 Registers
Receive FIFO 2 (Read)
Value after reset: 00H
7
0
RFIFO2
RF7
RF0
(9C)
RFIFO2
RF15
RF8
(9D)
RF(15:0)
Receive FIFO - HDLC Channel 2
The function is equivalent to RFIFO of HDLC channel 1.
Receive FIFO 3 (Read)
Value after reset: 00H
7
0
RFIFO3
RF7
RF0
(9E)
RFIFO3
RF15
RF8
(9F)
RF(15:0)
Receive FIFO - HDLC Channel 3
The function is equivalent to RFIFO of HDLC channel 1.
Identification Register (Read)
Value after reset: xxxxxx11
7
WID
x
0
x
x
x
x
x
1
1
(EC)
Additional version identification register.
Data Sheet
445
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11
Electrical Characteristics
11.1
Absolute Maximum Ratings
Parameter
Symbol
Ambient temperature under bias
– 40 to 85
°C
– 65 to 125
°C
– 0.4 to 6.5
V
– 0.4 to 6.5
V
– 0.4 to 6.5
V
Voltage on any pin with respect to ground
TA
Tstg
VDD
VDDR
VDDX
VS
– 0.4 to 6.5
V
ESD robustness1) HBM: 1.5 kΩ, 100 pF
VESD,HBM
2000
V
Storage temperature
IC supply voltage (digital)
IC supply voltage receive (analog)
IC supply voltage transmit (analog)
1)
Limit Values
Unit
According to JEDEC standard JESD22-A114.
Note: Stresses above those listed here may cause permanent damage to the
device. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
11.2
Operating Range
Parameter
Ambient temperature
Supply voltages
Analog input voltages
Digital input voltages
Ground
1)
Symbol
TA
VDD
VDDR
VDDX
VIA
VID
VSS
VSSR
VSSX
Limit Values
Unit Test Condition
min.
max.
-40
85
°C
3.13
3.46
V
3.3 V ± 5%
1)
0
VDDR+0.3 V
0
5.25
V
0
0
V
VDD = 5.0 V± 5%
Voltage ripple on analog supply less than 50 mV
Note: In the operating range, the functions given in the circuit description are fulfilled.
VDD, VDDR and VDDX have to be connected to the same voltage level,
VSS, VSSR and VSSX have to be connected to ground level.
Data Sheet
446
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.3
DC Characteristics
Parameter
Input low voltage
Input high voltage
Output low voltage
Output high voltage
Average power
supply current
(analog line interface
mode)
Symbol
VIL
VIH
VOL
VOH
IDDE1
Limit Values
Unit Notes
min.
max.
– 0.4
0.8
V
1)
2.0
5.25
V
1)
VSS
0.45
V
2.4
VDD
V
IOL = + 2 mA 2)
IOH = - 2 mA 2)
145
mA
E1 application3)
LIM1.DRS=0
mA
T1 application4)
LIM1.DRS=0
mA
LIM1.DRS=15)
µA
VIN =VDD6);
typ. 80
IDDT1
145
typ. 80
Average power supply
current (digital line
interface mode)
IDD
Input leakage current
IIL11
90
typ. 50
1
all except RDO
Input leakage current
IIL12
1
µA
VIN =VSS 6);
all except RDO
Input pullup current
Output leakage current
IIP
IOZ1
2
15
µA
1
µA
VIN =VSS
VOUT = tristate1)
VSS < Vmeas < VDD
measured against
VDD and VSS;
all except XL1/2
2.5
µA
XL1/2 = VDDX;
XPM2.XLT = 1
2.5
µA
XL1/2 = VSSX;
XPM2.XLT = 1
3
Ω
applies to XL1and
XL27)
Transmitter output current IX
105
mA
XL1, XL2
Differential peak voltage of VX
a mark
(between XL1 and XL2)
2.15
V
Transmitter leakage
current
Transmitter output
impedance
Data Sheet
ITL
RX
447
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Parameter
Symbol
Limit Values
min.
Receiver differential peak
voltage of a mark
(between RL1 and RL2)
VR
Unit Notes
max.
VDDR+0.3 V
Receiver input impedance ZR
50
(typical value)
RL1, RL2
kΩ
8)
Receiver sensitivity
SRSH
0
10
dB
RL1, RL2
LIM0.EQON=0
(short-haul)
Receiver sensitivity
SRLH
0
43
dB
RL1, RL2
LIM0.EQON=1
(E1, long-haul)
0
36
Receiver input threshold
VRTH
45
RL1, RL2
LIM0.EQON=1
(T1/J1, long-haul)
%
LIM2.SLT(1:0)=11
7)
50
55
LIM2.SLT(1:0)=10
default setting7)
LIM2.SLT(1:0)=00
7)
67
LIM2.SLT(1:0)=01
7)
Data Sheet
448
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Parameter
Symbol
Limit Values
min.
Loss-Of-signal (LOS)
detection limit in shorthaul mode
VLOSSH
Unit Notes
max.
0.91
0.74
0.59
0.42
0.32
0.21
0.16
0.10
(typical values)
V
RIL(2:0)=000
RIL(2:0)=001
RIL(2:0)=010
RIL(2:0)=011
RIL(2:0)=100
RIL(2:0)=101
RIL(2:0)=110
RIL(2:0)=111
7)
8)
LOS detection limit in
long-haul mode
VLOSLH
1.70
0.84
0.84
0.45
0.45
0.20
0.10
not defined
(typical values)
V
RIL(2:0)=000
RIL(2:0)=001
RIL(2:0)=010
RIL(2:0)=011
RIL(2:0)=100
RIL(2:0)=101
RIL(2:0)=110
RIL(2:0)=111
7)
8)
1)
Applies to all input pins except analog pins RLx
2)
Applies to all output pins except pins XLx
3)
Wiring conditions and external circuit configuration according to Figure 107 and Table 90 on page 476.
4)
Wiring conditions and external circuit configuration according to Figure 107 and Table 91 on page 477.
5)
System interface at 16 MHz; all-ones data.
6)
Pin leakage is measured in a test mode with all internal pullups disabled. RDO pins are not tristatable, no
leakage is measured.
7)
Parameter not tested in production
8)
Differential input voltage between pins RL1 and RL2; depends on programming of register LIM1.RIL(2:0)
Note: Typical characteristics specify mean values expected over the production spread.
If not specified otherwise, typical characteristics apply at TA=25 °C and 3.3V
supply voltage.
Data Sheet
449
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4
AC Characteristics
11.4.1
Master Clock Timing
1
2
3
MCLK
F0007
Figure 81
MCLK Timing
Table 70
MCLK Timing Parameters
No.
Parameter
Limit Values
min.
1
Clock period of MCLK
488
ns
E1,
fixed mode
648
ns
T1/J1,
fixed mode
typ.
max.
980.4 ns
%
High phase of MCLK
40
3
Low phase of MCLK
40
if clock divider programming fits without rounding
2)
if clock divider programming requires rounding
E1/T1/J1,
flexible mode
%
1)
32
1)
Data Sheet
Condition
50
2
Clock accuracy
Unit
450
28
2)
ppm
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.2
JTAG Boundary Scan Interface
1
TRS
2
3
4
TCK
5
6
7
8
TMS, TDI
TDATI
9
TDO, TDATO
F0120
Figure 82
JTAG Boundary Scan Timing
Table 71
JTAG Boundary Scan Timing Parameter Values
No.
Parameter
Limit Values
min.
Unit
max.
1
TRS reset active low time
200
ns
2
TCK period
250
ns
3
TCK high time
80
ns
4
TCK low time
80
ns
5
TMS, TDI setup time
40
ns
6
TMS, TDI hold time
40
ns
7
TDATI setup time
40
ns
8
TDATI hold time
40
ns
9
TDO, TDATO output delay
100
ns
Identification Register: 32 bit; Version: 3H; Part Number: 59H, Manufacturer: 083H
Data Sheet
451
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.3
Reset
1
RES
F0008
Figure 83
Reset Timing
Table 72
Reset Timing Parameter Values
No.
Parameter
Limit Values
min.
1
1)
101)
RES pulse width low
Unit
max.
µs
while MCLK is running
Data Sheet
452
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.4
Microprocessor Interface
11.4.4.1 Intel Bus Interface Mode
Ax
BHE
CS
3
3A
1
2
RD
WR
Figure 84
ITT10975
Intel Non-Multiplexed Address Timing
Ax
BHE
5
4
6
ALE
7
7A
1
CS
3
3A
RD
WR
Figure 85
Data Sheet
ITT10977
Intel Multiplexed Address Timing
453
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
CS
8
9
RD
9
8
WR
11
10
Dx
F0121
Figure 86
Intel Read Cycle Timing
CS
9
14
8
13
WR
129
RD
15
16
D7... D0
(D15... D8)
ITT06471
Figure 87
Data Sheet
Intel Write Cycle Timing
454
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Table 73
No.
Intel Bus Interface Timing Parameter Values
Parameter
Limit Values
min.
Unit
max.
1
Address, BHE setup time
5
ns
2
Address, BHE hold time
0
ns
3
CS setup time
0
ns
3A
CS hold time
0
ns
4
Address, BHE stable before ALE inactive
20
ns
5
Address, BHE hold after ALE inactive
10
ns
6
ALE pulse width
30
ns
7
ALE setup time before command active
0
ns
7A
ALE to command inactive delay
30
ns
8
RD, WR pulse width
80
ns
9
RD, WR control interval
70
ns
10
Data valid after RD active
11
Data hold after RD inactive
10
15
Data stable before WR inactive
30
ns
16
Data hold after WR inactive
10
ns
Data Sheet
455
75
ns
30
ns
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.4.2 Motorola Bus Interface Mode
Ax, BLE
17
18
CS
19
RW
19A
20
21
22
23
DS
24
25
Dx
Figure 88
F0122
Motorola Read Cycle Timing
Ax
BLE
17
18
CS
19
19A
RW
20
21
22A
23
DS
26
27
D7... D0
(D15 ... D8)
ITT10974
Figure 89
Motorola Write Cycle Timing
Data Sheet
456
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Table 74
No.
Motorola Bus Interface Timing Parameter Values
Parameter
Limit Values
min.
Unit
max.
17
Address, BLE setup time before DS active
15
ns
18
Address, BLE hold after DS inactive
0
ns
19
CS active before DS active
0
ns
19A
CS hold after DS inactive
0
ns
20
RW stable before DS active
10
ns
21
RW hold after DS inactive
0
ns
22
DS pulse width (read access)
80
ns
22A
DS pulse width (write access)
70
ns
23
DS control interval
70
ns
24
Data valid after DS active (read access)
25
Data hold after DS inactive (read access)
10
26
Data stable before DS active (write access)
30
ns
27
Data hold after DS inactive (write access)
10
ns
Data Sheet
457
75
ns
30
ns
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.5
Line Interface
30
32
31
RCLKI
33
34
ROID
30A
RDIP
RDIN
F0264_1
Figure 90
Digital Line Interface Receive Timing
35
37
36
XCLK
38
38
XOID1)
XOID
XDOP
XDON
XFM
1)
Figure 91
Data Sheet
CMI coding
F0264_2
Digital Line Interface Transmit Timing
458
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Table 75
No.
Digital Line Interface Parameter Values
Parameter
Limit Values
E1
min.
typ.
Unit
T1
max.
min.
488
typ.
max.
30
RCLKI clock period
30A
RDIP/RDIN period high
122
31
RCLKI clock period low
180
240
ns
32
RCLKI clock period high
180
240
ns
33
ROID setup
50
50
ns
34
ROID hold
50
50
ns
35
XCLK clock period
36
XCLK clock period low
XCLK clock period low1)
190
150
230
200
ns
37
XCLK clock period high
XCLK clock period high1)
190
150
230
200
ns
38
XOID delay2)
XDOP/XDON delay3)
244
648
366
162
488
324
ns
486
648
60
ns
ns
60
ns
1)
depends on input RCLKI in optical interface and remote loop without transmit jitter attenuator enabled
(LIM1.JATT/RL=01)
2)
NRZ coding
3)
HDB3/AMI/B8ZS coding
Data Sheet
459
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.6
System Interface
1
2
3
RCLK (output)
4
RFSP
data valid
Note: active edge can be programmed to be positive or negative (only negative edge timing
shown here); valid only, if RCLK id derived from DPLL (not, if RCLK jitter is attenuated)
F0009
Figure 92
RCLK, RFSP Output Timing
Table 76
RCLK, RFSP Timing Parameter Values
No.
Parameter
Limit Values
min.
1
typ.
Unit
max.
RCLK period E1 (2.048 MHz)
488
ns
RCLK period E1 (2.048 MHz × 4)
122
ns
RCLK period T1/J1 (1.544 MHz)
648
ns
RCLK period T1/J1 (1.544 MHz × 4)
162
ns
2
RCLK pulse high
40
60
%
3
RCLK pulse low
40
60
%
4
RFSP delay
80
ns
Data Sheet
460
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
1
2
3
SCLKR
SCLKX
(input)
F0010
Figure 93
SCLKR/SCLKX Input Timing
Table 77
SCLKR/SCLKX Timing Parameter Values
No.
Parameter
Limit Values
min.
typ.
Unit
max.
1
SCLKR/SCLKX period at 16.384 MHz
61
ns
1
SCLKR/SCLKX period at 8.192 MHz
122
ns
1
SCLKR/SCLKX period at 4.096 MHz
244
ns
1
SCLKR/SCLKX period at 2.048 MHz
488
ns
1
SCLKR/SCLKX period at 12.352 MHz
81
ns
1
SCLKR/SCLKX period at 6.176 MHz
162
ns
1
SCLKR/SCLKX period at 3.088 MHz
324
ns
1
SCLKR/SCLKX period at 1.544 MHz
648
ns
2
SCLKR/SCLKX pulse high
40
%
3
SCLKR/SCLKX pulse low
40
%
Data Sheet
461
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
positive edge timing 1)
negative edge timing
1)
SCLKR
1
RDO
RSIG
RSIGM
DLR
RFM
RMFB
FREEZE
2
data valid
1
2
data valid
1)
active edge can be programmed to be positive or negative
F0011
Figure 94
System Interface Marker Timing (Receive)
Table 78
System Interface Marker Timing Parameter Values
No.
Parameter
Limit Values
min.
typ.
Unit
max.
SCLKR input mode
1
RDO delay
0
35
ns
2
RSIGM, RMFB, DLR, RFM, FREEZE, RSIG
marker delay
0
45
ns
SCLKR output mode
1A
RDO delay
-55
-20
ns
2A
RSIGM, RMFB, DLR, RFM, FREEZE, RSIG
marker delay
-55
-20
ns
SCLKR can be input or output.
Data Sheet
462
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
1
active edge
SCLKR
SCLKX
2
3
SYPR
SYPX
inactive
active low
5
6
XMFS
4
inactive
7
active low
F0012
Figure 95
SYPR, SYPX Timing
Table 79
SYPR/SYPX Timing Parameter Values
No.
Parameter
Limit Values
min.
typ.1)
Unit
max.
SCLKR input mode
1
SCLKR period (t1)
2
SYPR/SYPX inactive setup time
3
61
648
ns
1 x t1
ns
SYPR/SYPX setup time
5
ns
4
SYPR/SYPX hold time
15
ns
5
XMFS inactive setup time
1 x t1
ns
6
XMFS setup time
5
ns
7
XMFS hold time
15
ns
SCLKR output mode
1A
SCLKR period (t1)
2A
SYPR/SYPX inactive setup time
3A
SYPR/SYPX setup time
Data Sheet
61
463
648
ns
1 x t1
ns
10
ns
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Table 79
No.
SYPR/SYPX Timing Parameter Values (cont’d)
Parameter
Limit Values
min.
4A
SYPR/SYPX hold time
5A
XMFS inactive setup time
6A
7A
1)
typ.1)
Unit
max.
0
ns
1 x t1
ns
XMFS setup time
10
ns
XMFS hold time
0
ns
typical value, not tested in production
Data Sheet
464
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
active edge1)
SCLKR
SCLKX
1
XMFB
DLX
XSIGM
1)
active edge can be programmed to be positive or negative
F0013
Figure 96
System Interface Marker Timing (Transmit)
Table 80
System Interface Marker Timing Parameter Values1)
No.
Parameter
Limit Values
min.
typ.
Unit
max.
SCLKR input mode
1
XMFB, DLX, XSIGM delay
100
ns
-20
ns
SCLKR output mode
1A
1)
XMFB, DLX, XSIGM delay
Parameters based on SCLKR when CMR2.IXSC = 1 and on SCLKX when CMR2.IXSC = 0 (input mode only)
Data Sheet
465
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
active edge1)
SCLKR
SCLKX
1
2
3
4
XDI
XSIG
1)
active edge can be programmed to be positive or negative
F0014
Figure 97
XDI, XSIG Timing
Table 81
XDI, XSIG Timing Parameter Values1)
No.
Parameter
Limit Values
min.
typ.
Unit
max.
SCLKR input mode
1
XDI setup time
5
ns
2
XDI hold time
15
ns
3
XSIG setup time
5
ns
4
XSIG hold time
15
ns
SCLKR output mode
1A
XDI setup time
10
ns
2A
XDI hold time
20
ns
3A
XSIG setup time
10
ns
4A
XSIG hold time
20
ns
1)
Parameters based on SCLKR when CMR2.IXSC = 1 and on SCLKX when CMR2.IXSC = 0 (input mode only)
Data Sheet
466
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
1
2
3
TCLK
F0016
Figure 98
TCLK Input Timing
Table 82
TCLK Timing Parameter Values
No.
Parameter
Limit Values
min.
1
typ.
Unit
max.
TCLK period E1 (2.048 MHz)
488
ns
TCLK period E1 (2.048 MHz × 4)
122
ns
TCLK period T1/J1 (1.544 MHz)
648
ns
TCLK period T1/J1 (1.544 MHz × 4)
162
ns
2
TCLK high
40
%
3
TCLK low
40
%
Data Sheet
467
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
MCLK
1
XCLK
F0123
Figure 99
XCLK Timing
Table 83
XCLK Timing Parameter values
No.
Parameter
Limit Values
E1
min.
1
1)
typ.
1)
XCLK delay
Unit
T1
max.
100
min.
typ.
max.
100
ns
valid in transmit buffer bypass mode only
Data Sheet
468
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
1
2
3
SEC
(input)
4
5
6
SEC1)
(output)
1)
clock running continuously
F0018
Figure 100
SEC Timing
Table 84
SEC Timing Parameter Values
No.
Parameter1)
Limit Values
min.
typ.
max.
1
SEC input period E1/T1/J1
2
SEC input high E1
976
ns
SEC input high T1/J1
1296
ns
SEC input low E1
976
ns
SEC input low T1/J1
1296
ns
3
1
Unit
4
SEC output period E1/T1/J1
5
SEC high output E1
976
ns
SEC high output T1/J1
1296
ns
1)
1
s
s
typical value, not tested in production
Data Sheet
469
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
1
2
FSC
3
RCLK
4
SCLKR
(output)
F0124
Figure 101
FSC Timing
Table 85
FSC Timing Parameter Values
No.
Parameter
Limit Values
min.
typ.
Unit
max.
1
FSC1) period
125
µs
2
FSC high/low active time E1
488
ns
2
FSC high/low active time T1/J1
648
ns
3
RCLK to FSC delay
50
80
ns
4
SCLKR to FSC delay
50
80
ns
1)
FSC can be programmed to be active high or active low (only the active low timing diagram is shown here)
Data Sheet
470
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
1
2
SYNC
F0125
Figure 102
SYNC Timing
Table 86
SYNC Timing Parameter Values
No.
Parameter
Limit Values
min.
typ.
Unit
max.
1
SYNC high time
30
%
2
SYNC low time
30
%
Data Sheet
471
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.7
Pulse Templates - Transmitter
11.4.7.1 Pulse Template E1
269 ns
(244 + 25)
V=100 %
10 % 10 %
20 %
20 %
194 ns
(244 - 50)
Nominal Pulse
50 %
244 ns
10 % 10 %
20 %
0%
10 % 10 %
219 ns
(244 - 25)
488 ns
(244 + 244)
ITD00573
Figure 103
Data Sheet
E1 Pulse Shape at Transmitter Output
472
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.4.7.2 Pulse Template T1
Normalized Amplitude
V = 100 %
50 %
0
-50 %
0
250
500
750
1000
ns
t
ITD00574
Figure 104
T1 Pulse Shape at the Cross Connect Point
Table 87
T1 Pulse Template at Cross Connect Point (T1.1021))
Maximum Curve
Minimum Curve
Time [ns]
Level [%]2)
Time [ns]
Level [%]
0
5
0
-5
250
5
350
-5
325
80
350
50
325
115
400
95
425
115
500
95
500
105
600
90
675
105
650
50
725
-7
650
-45
1100
5
800
-45
1250
5
925
-20
1100
-5
1250
-5
1)
requirements of ITU-T G.703 are also fulfilled
2)
100 % value must be in the range of 2.4 V and 3.6 V;
tested at 0 ft. and 655 ft. using PIC 22AWG cable characteristics.
Data Sheet
473
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.5
Capacitances
Parameter
Symbol
Limit Values
min.
max.
Unit Notes
Input capacitance1)
CIN
5
10
pF
Output capacitance1)
COUT
8
15
pF
all except XLx
Output capacitance1)
COUT
8
20
pF
XLx
1)
Not tested in production.
11.6
Package Characteristics
F0051
Figure 105
Thermal Behavior of Package
Table 88
Package Characteristic Values
Parameter
Symbol
Limit Values
min.
typ.
Thermal Resistance
MQFP
Rthjam1)
47
Rthjc2)
9
Thermal Resistance BGA
Rthjab1)
29
Junction Temperature
Rj
1)
Rthja = (Tjunction - Tambient)/Power
Not tested in production.
2)
Rthjc = (Tjunction - Tcase)/Power
Not tested in production.
Data Sheet
max.
K/W single layer PCB,
K/W no convection
K/W single layer PCB,
natural convection
125
474
Unit Notes
°C
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.7
Test Configuration
11.7.1
AC Tests
Test Levels
VTH
Device
under
Test
VTL
CL
Timing Test
Points
Drive Levels
VIH
F0067
VIL
Figure 106
Input/Output Waveforms for AC Testing
Table 89
AC Test Conditions
Parameter
Symbol
Load Capacitance
CL
50
pF
Input Voltage high
VIH
2.4
V
all except RLx
Input Voltage low
VIL
0.4
V
all except RLx
Test Voltage high
VTH
2.0
V
all except XLx
Test Voltage low
VTL
0.8
V
all except XLx
Data Sheet
475
Test
Values
Unit Notes
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
11.7.2
Power Supply Test
tt1 : tt2
R1
R1
RL
PCM Highway
FALC®56
tr1 : tr2
VDD
VDDX
VDDR
R2
F0176
Figure 107
Device Configuration for Power Supply Testing
Table 90
Power Supply Test Conditions E1
Parameter
Symbol
Load Resistance
R1
7.5
Ω
1%
Termination Resistance
R2
120
Ω
1%
Line Impedance
RL
120
Ω
Line Length
L
< 0.2
m
Transformer Ratio Transmit
tt1 : tt2
2.4
Transformer Ratio Receive
tr1 : tr2
1
PCM Highway Frequency
SCLKX
SCLKR
2.048
XPM2
00H
XPM1
03H
XPM0
BDH
Ambient Temperature
Data Sheet
Unit Notes
MHz
215-1
Test Signal
Pulse Mask Programming
Test
Values
85
476
PRBS pattern
°C
2002-08-27
FALC56 V1.2
PEB 2256
Electrical Characteristics
Table 91
Power Supply Test Conditions T1/J1
Parameter
Symbol
Load Resistance
R1
2
Ω
1%
Termination Resistance
R2
100
Ω
1%
Line Impedance
RL
100
Ω
Line Length
L
< 0.2
m
Transformer Ratio Transmit
tt1 : tt2
2.4
Transformer Ratio Receive
tr1 : tr2
1
PCM Highway Frequency
SCLKX
SCLKR
1.544
XPM2
02H
XPM1
27H
XPM0
9FH
Ambient Temperature
Data Sheet
Unit Notes
MHz
215-1
Test Signal
Pulse Mask Programming
Test
Values
85
477
PRBS pattern
°C
2002-08-27
FALC56 V1.2
PEB 2256
Package Outlines
12
Package Outlines
P-MQFP-80-1
(Plastic Metric Quad Flat Package)
Sorts of Packing
Package outlines for tubes, trays etc. are contained in our
Data Book “Package Information”.
SMD = Surface Mounted Device
Data Sheet
478
Dimensions in mm
2002-08-27
FALC56 V1.2
PEB 2256
Package Outlines
P-LBGA-81-1
(Plastic Ball Grid Array Package)
GPA0LB81
Sorts of Packing
Package outlines for tubes, trays etc. are contained in our
Data Book “Package Information”.
SMD = Surface Mounted Device
Data Sheet
479
Dimensions in mm
2002-08-27
FALC56 V1.2
PEB 2256
Appendix
13
Appendix
13.1
Protection Circuitry
The design in Figure 108 shows an example of how to build up a generic E1/T1/J1
platform. The circuit shown has been successfully checked against ITU-T K.20 and K.21
lightning surge tests (basic level).
1:1
RL1
R3
PTC
R2
A
VDD
RL2
B
VSS
Fuse
1.25 A
A
PTC
R3
Fuse
1.25 A
®
FALC
RJ45
1:2.4
XL1
PTC
R1
A
B
VDD
XL2
VSS
Fuse
1.25 A
A
PTC
R1
Fuse
1.25 A
A SMP 100LC-35 (~65 pF)
F0262_2
B SMP P3500SC (~60 pF)
Figure 108
Data Sheet
Protection Circuitry Examples
480
2002-08-27
FALC56 V1.2
PEB 2256
Appendix
13.2
Application Notes
Several application notes and technical documentation provide additional information.
Online access to supporting information is available on the internet page:
http://www.infineon.com/falc
On the same page you find as well the
• Boundary Scan File for FALC56 Version 1.2 (BSDL File)
13.3
Software Support
The following software package is provided together with the FALC56 Reference System
EASY2256:
• E1 and T1 driver functions supporting different ETSI, AT&T and Telcordia (former:
Bellcore) requirements
• IBIS model for FALC56 Version 1.2 (according to ANSI/EIA-656)
• Flexible Master Clock Calculator
• External Line Front End Calculator
To make system design easier, two software tools are available. The first is the "Master
Clock Frequency Calculator", which calculates the required register settings depending
on the external master clock frequency (MCLK). The second is the "External Line Front
End Calculator" which provides an easy method to optimize the external components
depending on the selected application type. Calculation results are traced an can be
stored in a file or printed out for documentation. The tools run under a Win9x/NT
environment.
Screenshots of both programs are shown in Figure 109 and Figure 110 below.
Data Sheet
481
2002-08-27
FALC56 V1.2
PEB 2256
Appendix
F0126
Figure 109
Data Sheet
Master Clock Frequency Calculator
482
2002-08-27
FALC56 V1.2
PEB 2256
Appendix
F0198_2256
Figure 110
Data Sheet
External Line Frontend Calculator
483
2002-08-27
FALC56 V1.2
PEB 2256
Glossary
14
Glossary
A/D
Analog to digital
ADC
Analog to digital converter
AIS
Alarm indication signal (blue alarm)
AGC
Automatic gain control
ALOS
Analog loss of signal
AMI
Alternate mark inversion
ANSI
American National Standards Institute
ATM
Asynchronous transfer mode
AUXP
Auxiliary pattern
B8ZS
Line coding to avoid too long strings of consecutive "0"
BER
Bit error rate
BFA
Basic frame alignment
BOM
Bit orientated message
Bellcore
Bell Communications Research
BPV
Bipolar violation
BSN
Backward sequence number
CAS
Channel associated signaling
CAS-BR
Channel associated signaling - bit robbing
CAS-CC
Channel associated signaling - common channel
CCS
Common channel signaling
CMI
coded mark inversion code (also known as 1T2B code)
CR
Command/Response (special bit in PPR)
CRC
Cyclic redundancy check
CSU
Channel service unit
CVC
Code violation counter
DCO
Digitally controlled oscillator
DL
Digital loop
DPLL
Digitally controlled phase locked loop
DS1
Digital signal level 1
EA
Extended address (special bit in PPR)
Data Sheet
484
2002-08-27
FALC56 V1.2
PEB 2256
Glossary
ESD
Electrostatic discharge
EASY
Evaluation system for FALC products
ESF
Extended superframe (F24) format
EQ
Equalizer
ETSI
European Telecommunication Standards Institute
FALC®
Framing and line interface component
FAS
Frame alignment sequence
FCC
US Federal Communication Commission
FCS
Frame check sequence (used in PPR)
FISU
Fill in signaling unit
FPS
Framing pattern sequence
FSN
Forward sequence number
HBM
Human body model for ESD classification
HDB3
High density bipolar of order 3
HDLC
High level data link control
IBIS
I/O buffer information specification (ANSI/EIA-656)
IBL
In band loop (=LLB)
ISDN
Integrated services digital network
ITU
International Telecommunications Group
JATT
Jitter attenuator
JTAG
Joined Test Action Group
LAPD
Link access procedure on D-channel
LBO
Line build out
LCV
Line code violation
LIU
Line interface unit
LFA
Loss of frame alignment
LL
Local loop
LLB
Line loop back (= IBL)
LOS
Loss of signal (red alarm)
LSB
Least significant bit
LSSU
Link status signaling unit
MF
Multiframe
Data Sheet
485
2002-08-27
FALC56 V1.2
PEB 2256
Glossary
MSB
Most significant bit
MSU
Message signaling unit
NRZ
Non return to zero signal
PDV
Pulse-density violation
PLB
Payload loop back
PLL
Phase locked loop
PMQFP
Plastic metric quad flat pack (device package)
PPR
Periodical performance report
PRBS
Pseudo random binary sequence
PTQFP
Plastic thin metric quad flat pack (device package)
RAI
Remote alarm indication (yellow alarm)
RL
Remote loop
SAPI
Service access point identifier (special octet in PPR)
SF
Superframe
Sidactor
Overvoltage protection device for transmission lines
TAP
Test access port
TEI
Terminal endpoint identifier (special octet in PPR)
UI
Unit interval
ZCS
Zero code suppression
Data Sheet
486
2002-08-27
FALC56 V1.2
PEB 2256
Index
CMDR4 270, 390
CMR1 258, 378
CMR2 259, 379
COEC 421
CRC16 74, 100, 135, 161
CRC-Multiframe 83
CVC 299, 417
A
Address Bus 29
Address Latch Enable 30
Alarm Simulation 118, 186
Application Notes 481
Applications 22, 24
D
B
BEC 420
Bit Oriented Message 209
Bit Oriented Messages 137
Bit Robbing 137, 161, 162
Boundary Scan 49, 57, 451, 481
BSN 100, 161
Bus High/Low Enable 31
C
CAS 76, 77, 101, 137, 161, 162, 193
CCBx 363
CCR1 221, 338
CCR2 224, 341
CCR3 271, 391
CCR4 273, 393
CCR5 274, 394
CEC 418
CEC1 300
CEC2 302
CEC3 303
Channel Associated Signaling 76, 77, 101
Channel Translation Mode 131
Chip Select 31
Clear Channel 153, 155, 162
Clock and Data Recovery 61, 120
Clock of DCO-R 36
Clock of DCO-X 37
Clock Synchronization 36
Clocking Unit 59, 60
CMDR 217, 334
CMDR2 269, 389
CMDR3 269, 389
Data Sheet
D4 139, 143
Data Bus 29
Data Bus Width 30
Data Link Access 211
Data Link Bit Receive 42
Data Link Bit Transmit 47
Data Strobe 30
DEC 262, 382
Defect Insertion 118, 186
DLR 42
DLX 47
Doubleframe Format 80
E
EBC 300, 301, 419
Elastic Buffer 70, 97, 129, 157
Error counter 92, 152
ESD 446
ESF 139, 144, 162
ESM 262, 382
F
F12 139, 140
F24 139, 144, 162
F4 139, 142
F72 139, 140, 211
FEC 298, 416
FIFO Structure 53
FISU 74, 100, 135, 161
FMR0 228, 345
FMR1 230, 347
FMR2 232, 349
FMR3 245
FMR4 352
487
2002-08-27
FALC56 V1.2
PEB 2256
FMR5 354
Fractional E1 Access 257
Fractional T1/J1 Access 377
Frame Aligner 20
Frame Synchronous Pulse 43
FRS0 291, 411
FRS1 294, 413
FRS2 415
FSN 100, 161
G
GCM1 277, 397
GCM2 277, 397
GCM3 278, 398
GCM4 278, 399
GCM5 279, 400
GCM6 279, 400
GCR 261, 381
GIS 55, 321, 437
GPC1 267, 387
H
HDLC 192, 201
I
IBIS Model 481
ICBx 246, 364
IDLE 243, 362
IEEE 1149.1 57
IERR 227, 345
IMRx 227, 344
In-Band Loop 92, 153
Initialization in E1 Mode 188
Initialization in T1/J1 Mode 194
INT 55
Interface Mode 31
Interrupt 31
Interrupt Interface 55
IPC 56, 221, 338
IS 55
ISR0 310, 428
ISR1 312, 430
ISR2 314, 431
Data Sheet
ISR3 316, 433
ISR4 317, 434
ISR5 319, 436
J
J1-Features 187
Jitter 66, 96, 125, 155
JTAG 49
L
LCR1 251, 370
LCR2 253, 372
LCR3 253, 372
LIM0 247, 364
LIM1 248, 366
LIM2 250, 369
Line Build-Out 159
Line Coding 62, 121
Line Interface 19, 32, 34, 458
Line Monitoring 63, 123
Local Loop 116, 184
LOOP 233, 351
LOS 449
Loss of Signal 65, 124
LSSU 74, 135
M
Master Clock 36, 59
Microprocessor Interface 21, 52, 453
MODE 219, 336
MODE2 275, 395
MODE3 276, 396
MSU 74, 135
Multifunction Port 40, 44
O
One-Second Timer 37, 92, 152
P
Payload Loop Back 117, 183
P-BGA-81 479
PC1...4 264, 384
PC5 266, 386
488
2002-08-27
FALC56 V1.2
PEB 2256
PC6 268, 388
PCD 249, 367
PCR 250, 368
Performance Monitoring 85, 150
Periodical Performance Report 162
Power Supply 48
PPR 162, 389, 395
Protection 480
Protection Switching 124
Pseudo-Random Bit Sequence 114, 182
P-TQFP-144-8 478
Pulse Density 153
Pulse Shaper 98, 159
Pulse Template 472, 473
R
RAH1 220, 337
RAH2 220, 337
RAL1 220, 337
RAL2 220, 337
RBC2 323, 439
RBC3 323, 439
RBCH 310, 427
RBCL 310, 427
RBD 289, 409
RC0 238, 357
RC1 239, 359
RDL1 422
RDL2 422
RDL3 423
Read Enable 30
Read/Write Enable 30
Receive Clock 38
Receive Clock Input 33
Receive Data Input 32, 33
Receive Data Out 39
Receive Equalization Network 61, 120
Receive Frame Marker 41
Receive Line Attenuation Indication 61,
120
Receive Line Interface 60, 119
Receive Multiframe Begin 41
Receive Optical Interface 32
Data Sheet
Receive Signaling Data 42
Receive Signaling Marker 42
Register Addresses 213, 286, 330, 407
Remote Loop 114, 182
RES 48, 290, 410
Reset 48, 188, 194, 452
RFIFO 289, 409
RFIFO2 329, 445
RFIFO3 329, 445
RFM 41
RFSP 43
RMFB 41
RS1...12 438
RS1...16 322
RSA6S 305
RSAx 304
RSIG 42
RSIGM 42
RSIS 308, 425
RSIS2 325, 440
RSIS3 327, 443
RSP 296
RSP1 306, 423
RSP2 306, 423
RSW 295
RTR1...4 225
RTRx 342
S
Sa bit Access 208
SAPI 395
SCLKX 43
SF 143
SIC1 254, 373
SIC2 255, 374
SIC3 256, 376
Signaling Controller 21, 73, 99, 134, 160
Single Channel Loop Back 117, 185
SIS 307, 424
SIS2 323, 439
SIS3 326, 442
SLC96 139, 146
Software 481
489
2002-08-27
FALC56 V1.2
PEB 2256
SS7 74, 100, 135, 161, 219, 336
SU 74, 100, 135, 161
Supply voltage 446
Synchronous Pulse Receive 40
Synchronous Pulse Transmit 45
SYPX 45
System Clock Receive 39
System Clock Transmit 43
System Interface 39, 43, 102, 165, 460
T
TCLK 46
Test Access Port 57
Test Clock 49
Test Data Input 49
Test Data Output 49
Test Mode Select 49
Test Reset 49
Time-Slot Assigner 113, 180
TPC0 285, 406
Transmit Clock 46, 47
Transmit Data In 43
Transmit Data Output 34, 35
Transmit Frame Marker 35
Transmit Line Interface 95, 154
Transmit Line Monitor 98, 160
Transmit Line Tristate 47
Transmit Multiframe Begin 46
Transmit Multiframe Synchronization 45
Transmit Optical Interface 34
Transmit Signaling Data 45
Transmit Signaling Marker 46
Transparent Mode 204
TSBS1 282, 403
TSBS2 283, 404
TSBS3 283, 404
TSEO 281, 402
TSS2 284, 405
TSS3 284, 405
TSWM 242
TTR1...4 226
TTRx 343
Data Sheet
U
Unused Pins 49
V
VIS 56
VSTR 290, 410
W
WID 329, 445
Write Enable 30
X
XC0 236, 355
XC1 237, 356
XCLK 47
XDI 43
XDLx 362
XFIFO 217, 334
XFIFO2 281, 402
XFIFO3 281, 402
XLT 47
XMFB 46
XMFS 45
XPMx 241, 361
XS1...12 383
XS1...16 263
XSAx 244
XSIG 45
XSIGM 46
XSP 235
XSW 234
XTS16RA 221
490
2002-08-27