MICREL SY100S371FC

TRIPLE 4-INPUT
MULTIPLEXER
WITH ENABLE
SY100S371
DESCRIPTION
FEATURES
■ Max. propagation delay of 1000ps
■ IEE min. of –68mA
■ Industry standard 100K ECL levels
■ Extended supply voltage option:
VEE = –4.2V to –5.5V
■ Voltage and temperature compensation for improved
noise immunity
■ Internal 75KΩ input pull-down resistors
■ 40% faster than Fairchild
■ 40% lower power than Fairchild
■ Function and pinout compatible with Fairchild F100K
■ Available in 24-pin CERPACK and 28-pin PLCC
packages
The SY100S371 is an ultra-fast triple 4-input multiplexer
with true and complementary outputs designed for use in
high-performance ECL systems. The multiplexer is
controlled by common select inputs S0 and S1. A logic
HIGH on the Enable (E) control input takes the outputs to
a logic LOW. The inputs on the device have 75KΩ pulldown resistors.
I0a
Za
Za
I2a
I1a
VEES
I3a
PIN CONFIGURATIONS
11 10 9 8 7 6 5
S0
S1
VEE
VEES
E
I0b
BLOCK DIAGRAM
I1b
12
13
14
15
16
17
18
4
3
2
1
28
27
26
Top View
PLCC
J28-1
Zb
Zb
VCCA
VCC
VCC
Zc
Zc
S0
S1
I0b
E
VEE
I1b
I1c
I2c
I3c
VEES
I2b
S0
I3b
I0c
19 20 21 22 23 24 25
S1
I0a
I2b
1
24 23 22 21 20 19
18
I3a
I1a
I3b
I0c
2
3
17
16
I2a
I1a
I1c
I2c
4
5
15
14
I0a
Za
I3c
6
13
7 8 9 10 11 12
Za
I1b
Zc
I0b
Zb
Zb
Zb
I3a
VCCA
Za
VCC
Za
Zc
I2a
Top View
Flatpack
F24-1
Zb
I2b
I3b
I0c
I1c
Zc
Zc
I2c
I3c
E
Rev.: G
1
Amendment: /0
Issue Date: July, 1999
SY100S371
Micrel
TRUTH TABLE(1)
PIN NAMES
Pin
Function
Inputs
Outputs
I0X – I3X
Data Inputs (x = a, b or c)
E
S0
S1
Zn
S0, S1
Select Inputs
L
L
L
I0X
E
Enable Input (Active LOW)
L
H
L
I1X
Za – Z c
Data Outputs
L
L
H
I2X
Za – Z c
Complementary Data Outputs
L
H
H
I3X
VEES
VEE Substrate
H
X
X
L
VCCA
VCCO for ECL Outputs
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don't Care
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol
IIH
IEE
Parameter
Input HIGH Current
I0X – I3X
S0, S1, E
Power Supply Current
Min.
Typ.
Max.
—
—
—
—
250
300
–68
–48
–34
2
Unit
Condition
µA
VIN = VIH (Max.)
mA
Inputs Open
SY100S371
Micrel
AC ELECTRICAL CHARACTERISTICS
CERPACK
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
I0X – I3X to Output
300
1100
300
1100
300
1100
ps
tPLH
tPHL
Propagation Delay
S0, S1 to Output
400
1500
400
1500
400
1500
ps
tPLH
tPHL
Propagation Delay
S0, S1 to Output
400
1400
400
1400
400
1400
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
Condition
PLCC
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
I0X – I3X to Output
300
1000
300
1000
300
1000
ps
tPLH
tPHL
Propagation Delay
S0, S1 to Output
400
1400
400
1400
400
1400
ps
tPLH
tPHL
Propagation Delay
S0, S1 to Output
400
1300
400
1300
400
1300
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
3
Condition
SY100S371
Micrel
TIMING DIAGRAM
0.7 ± 0.1 ns
0.7 ± 0.1 ns
INPUT
–0.95V
80%
50%
20%
–1.69V
TRUE
tPHL
tPLH
50%
OUTPUT
tPLH
tPHL
80%
50%
20%
COMPLEMENT
tTLH
tTHL
Propagation Delay and Transition Times
NOTE:
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
PRODUCT ORDERING CODE
Ordering
Code
4
Package
Type
Operating
Range
SY100S371FC
F24-1
Commercial
SY100S371JC
J28-1
Commercial
SY100S371JCTR
J28-1
Commercial
SY100S371
Micrel
24 LEAD CERPACK (F24-1)
Rev. 03
5
SY100S371
Micrel
28 LEAD PLCC (J28-1)
Rev. 03
MICREL-SYNERGY
TEL
3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
+ 1 (408) 980-9191
FAX
+ 1 (408) 914-7878
WEB
http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or
other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc.
© 2000 Micrel Incorporated
6