Features ● ● ● ● ● ● ● ● 2:1 Wide Input Voltage Range 60 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield Design Meet Safety Standard Standard 100.2 x70.0x19.0mm Package Efficiency to 90% Selection Guide 12V, 24V and 48V Input Types Input Range VDC Output Voltage VDC Output Current mA Input (4) Current mA Efficiency(5) % Capacitive(6) Load max. µF RP60-123.3SE 9-18 3.3 15000 5430 80 38700 RP60-1205SE 9-18 5 12000 6330 83 20400 RP60-1212SE 9-18 12 5000 6250 84 3550 RP60-1215SE 9-18 15 4000 6250 84 2300 RP60-243.3SE 18-36 3.3 15000 2750 79 38700 RP60-2405SE 18-36 5 12000 3090 85 20400 RP60-2412SE 18-36 12 5000 2980 88 3550 RP60-2415SE 18-36 15 4000 2940 89 2300 RP60-483.3SE 36-75 3.3 15000 1310 83 38700 RP60-4805SE 36-75 5 12000 1520 86 20400 RP60-4812SE 36-75 12 5000 1470 89 3550 RP60-4815SE 36-75 15 4000 1450 90 2300 RP60-1205DE 9-18 ±5 +10000 / -2000 6500 81 17000 / 3400 RP60-1212DE 9-18 ±12 ±2500 6250 84 ±900 RP60-1215DE 9-18 ±15 ±2000 6250 84 ±600 RP60-2405DE 18-36 ±5 +10000 / -2000 3130 84 RP60-2412DE 18-36 ±12 RP60-2415DE 18-36 ±15 RP60-4805DE 36-75 ±5 RP60-4812DE 36-75 ±12 ±2500 1450 90 ±900 RP60-4815DE 36-75 ±15 ±2000 1450 90 ±600 RP60-123.305DE 9-18 3.3 / 5 6000 / 6000 5770 76 16000 / 10200 RP60-243.305DE 18-36 3.3 / 5 6000 / 6000 2700 81 16000 / 10200 RP60-483.305DE 36-75 3.3 / 5 6000 / 6000 1310 83 16000 / 10200 Part Number 258 ±2500 3050 86 ±2000 3010 87 +10000 / -2000 1540 85 April-2005 POWERLINE DC/DC-Converter RP60S_DE Series 60 Watt Single, Dual & Positive Dual Output 12000 / 1700 ±900 ±600 12000 / 1700 www.recom-international.com RP60-S_DE Series POWERLINE DC/DC-Converter Derating-Graph (Ambient Temperature) 125 100 Output Power (%) 75 50 Natural Convection 25 0 -25 0 25 35 50 60 70 80 90 100 Ambient Temperature Range (°C) Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at [email protected] Specifications (typical at nominal input and 25°C unless otherwise noted) Input Voltage Range Input Filter Input Surge Voltage (100 ms max.) 12V nominal input 24V nominal input 48V nominal input 12V Input 24V Input 48V Input Input Reflected Ripple (nominal Vin and full load) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see note 7) Remote OFF input current Pi Type 36VDC 50VDC 100VDC 40mAp-p DC-DC ON DC-DC OFF Nominal input Output Power 25ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 30mA 60W max. Output Voltage Accuracy (full Load and nominal Vin) Voltage Adjustability Minimum Load 9-18VDC 18-36VDC 36-75VDC ±2% RP60-xx3.305DE 3.3V Output others ±10% 800mA min. 10% of FL Line Regulation (LL-HL at full load) ±0.5% Load Regulation (25% to 100% FL) ±0.5% Cross Regulation (Note 8) ±5% Ripple and Noise (20MHz bandwith) 1%/p-p of Vout max. Temperature Coefficient Transient Response (25% load step change) Over Voltage Protection Zener diode clamp (only single) ±0.02%/°C, max. 3.3V 5V 12V 15V 500µS 3.9V 6.2V 15V 18V Short Circuit Protection Hiccup, automatic recovery Efficiency see „Selection Guide“ table continued on next page www.recom-international.com April-2005 259 POWERLINE RP60-S_DE Series DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Isolation Voltage 1.600VDC min. Isolation Resistance 109 Ω min. Isolation Capacitance 1000pF max. Operating Frequency 200kHz typ. Operating Temperature Range -25°C to +71°C(with derating) Maximum Case Temperature +95°C Storage Temperature Range Thermal Impedance -25°C to +105°C 5.2°C/Watt Natural convection Thermal Shock MIL-STD-810D Vibration 10-55Hz, 2G, 30 Min. along X, Y and Z Relative Humidity 5% to 95% RH Case Material Nickel-Coated copper Base Material Non-conductive black plastic FR4 Potting Material Conducted Emissions Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Epoxy (UL94-V0) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Weight Level A Level A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 48g Dimensions 100.2 x 70.0 x 19.0mm 1.533 x 106 Hours MTBF (see note 2) Notes : 1. The RP60 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment). 3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. Cross regulation: Dual output—Asymmetrical load 25% to 100% full load. 8. See application notes for EMI-filtering. 260 April-2005 www.recom-international.com POWERLINE RP60-S_DE Series DC/DC-Converter Package Style and Pinning (mm) 3rd angle projection 100.20 70.00 19.0 8.0 1.3 Pin Connections Monting inserts: #4-40 25.40 25.40 25.00 10.00 10.00 10.00 10.00 5 1 2 25.40 10.00 6 Bottom View 10.00 7 10.00 8 25.40 3 10.00 9 15.00 10.00 4 Pin # Single 1 +Vin 2 -Vin 3 CTRL 4 Trim 5 +Vout 6 +Vout 7 -Vout 8 -Vout 9 No Pin 10 No Pin NC = No Connection Dual +Vin -Vin CTRL Trim +Vout +Vout Com Com -Vout -Vout 3.3V / 5V +Vin -Vin CTRL Trim 3.3V 3.3V Com Com +5V +5V Pin Pitch Tolerance ±0.35 mm 10.00 10 7.60 82.60 External Output Trimming Output can be externally trimmed by using the method shown below. ( ) for dual output trim [ ] for RP60-xx3.305DE only trim 3.3V 7(9) [7] Trim Up 4(4) [4] RU 4(4) [4] www.recom-international.com Trim Down RD 6(6) [6] April-2005 261