STMICROELECTRONICS ST24LC21

ST24LC21
1Kb (x8) DUAL MODE SERIAL EEPROM
for VESA Plug&Play
NOT FOR NEW DESIGN
1 MILLION ERASE/WRITE CYCLES
40 YEARS DATA RETENTION
2.5V to 5.5V SINGLE SUPPLY VOLTAGE
400k Hz COMPATIBILITY OVER the FULL
RANGE of SUPPLY VOLTAGE
TWO WIRE SERIAL INTERFACE I2C BUS
COMPATIBLE
PAGE WRITE (up to 8 BYTES)
BYTE, RANDOM and SEQUENTIAL READ
MODES
SELF TIMED PROGRAMMING CYCLE
AUTOMATIC ADDRESS INCREMENTING
ENHANCED ESD/LATCH UP
PERFORMANCES
ST24LC21 is replaced by the ST24LC21B
8
8
1
1
PSDIP8 (B)
0.25mm Frame
SO8 (M)
Figure 1. Logic Diagram
DESCRIPTION
The ST24LC21 is a 1K bit electrically erasable
programmable memory (EEPROM), organized by
8 bits.This device can operate in two modes: Transmit Only mode and I2C bidirectional mode. When
powered, the device is in Transmit Only mode with
EEPROM data clocked out from the rising edge of
the signal applied on VCLK.
The device will switch to the I2C bidirectional mode
upon the falling edge of the signal applied on SCL
pin. The ST24LC21 cannot switch from the I2C
bidirectional mode to the Transmit Only mode (except when the power supply is removed). The
device operates with a power supply value as low
as 2.5V. Both Plastic Dual-in-Line and Plastic Small
Outline packages are available.
VCC
SDA
SCL
ST24LC21
VCLK
Table 1. Signal Names
SDA
Serial Data Address Input/Output
VSS
AI01489
2
SCL
Serial Clock (I C mode)
VCC
Supply Voltage
VSS
Ground
VCLK
Clock Transmit only mode
June 1997
This is information on a product still in production but not recommended for new designs.
1/18
ST24LC21
Figure 2A. DIP Pin Connections
Figure 2B. SO Pin Connections
ST24LC21
NC
NC
NC
VSS
8
7
6
5
1
2
3
4
ST24LC21
VCC
VCLK
SCL
SDA
NC
NC
NC
VSS
8
7
6
5
1
2
3
4
AI01499
VCC
VCLK
SCL
SDA
AI01500
Warning: NC = Not Connected
Warning: NC = Not Connected
Table 2. Absolute Maximum Ratings (1)
Symbol
TA
Parameter
Ambient Operating Temperature
TSTG
Storage Temperature
TLEAD
Lead Temperature, Soldering
VIO
Input or Output Voltages
VCC
Supply Voltage
VESD
Value
Unit
0 to 70
°C
–65 to 150
°C
215
260
°C
grade 1
(SO8 package)
(PSDIP8 package)
Electrostatic Discharge Voltage (Human Body model)
40 sec
10 sec
–0.3 to 6.5
V
–0.3 to 6.5
V
(2)
Electrostatic Discharge Voltage (Machine model) (3)
4000
V
500
V
Notes: 1. Except for the rating "Operating Temperature Range", stresses above those listed in the Table "Absolute Maximum Ratings"
may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other
conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum
Rating conditions for extended periods may affect device reliability. Refer also to the SGS-THOMSON SURE Program and other
relevant quality documents.
2. MIL-STD-883C, 3015.7 (100pF, 1500 Ω).
3. EIAJ IC-121 (Condition C) (200pF, 0 Ω).
Table 3. Device Select Code
Device Code
Chip Enable
RW
Bit
b7
b6
b5
b4
b3
b2
b1
b0
Device Select
1
0
1
0
X
X
X
RW
Note: The MSB b7 is sent first.
X = 0 or 1.
2/18
ST24LC21
Figure 3. Transmit Only Mode Waveforms
VCC
SCL
SDA
Bit 6
Bit 7
tVPU
VCLK
1
2
8
9
10
11
VCC
SCL
SDA
Bit 5
Bit 6
12
VCLK
Bit 4
Bit 0
13
17
Bit 6
Bit 7
18
19
20
AI01501
Table 4. Operating Modes
Mode
RW bit
VCLK
Bytes
Current Address Read
’1’
X
1
’0’
X
’1’
X
Sequential Read
’1’
X
1 to 128
Byte Write
’0’
VIH
1
START, Device Select, RW = ’0’
Page Write
’0’
VIH
8
START, Device Select, RW = ’0’
Random Address Read
1
Initial Sequence
START, Device Select, RW = ’1’
START, Device Select, RW = ’0’, Address,
reSTART, Device Select, RW = ’1’
Similar to Current or Random Mode
Note: X = VIH or VIL
3/18
ST24LC21
Figure 4. Transition Mode Waveforms
Transmit Only Mode
Bi-Directional Mode
SCL
SDA
VCLK
AI01502
Transmit Only Mode
After a Power-up, the device is in the Transmit Only
mode. A proper initialization sequence must supply
nine clock pulses on the VCLK pin (in order to
internally synchronize the device). During this initialization sequence, the SDA pin is in high impedance. On the rising edge of the tenth pulse applied
on VCLK pin, the device will output the first bit of
byte located at address 00h (most significant bit
first).
A byte is clocked out (on SDA pin) with nine clock
pulses on VCLK: 8 clock pulses for the data byte
and one extra clock pulse for a Don’t Care bit.
As long as the SCL pin is held high, each byte of
the memory array is transmitted serially on the SDA
pin with an automatic address increment.
When the last byte is transmitted, the address
counter will roll-over to location 00h.
I2C Bidirectional Mode
The device can be switched from Transmit Only
mode to I2C Bidirectional mode by applying a valid
high to low transition on the SCL pin (see Figure 4).
When the device is in the I2C Bidirectional mode,
the VCLK input enables (or inhibits) the execution
of any write instruction: if VCLK = 1, write instructions are executed; if VCLK = 0, write instructions
are not executed.
The device is compatible with the I2C standard, two
wire serial interface which uses a bi-directional data
4/18
bus and serial clock. The device carries a built-in 4
bit, unique device identification code (1010) corresponding to the I2C bus definition.
The device behaves as a slave device in the I2C
protocol with all memory operations synchronized
by the serial clock. Read and write operations are
initiated by a START condition generated by the
bus master. The START condition is followed by a
stream of 7 bits (identification code 1010XXX), plus
one read/write bit and terminated by an acknowledge bit.
When writing data to the memory it responds to the
8 bits received by asserting an acknowledge bit
during the 9th bit time. When data is read by the
bus master, it acknowledges the receipt of the data
bytes in the same way. Data transfers are terminated with a STOP condition.
Power On Reset: VCC lock out write protect. In
order to prevent data corruption and inadvertent
write operations during power up, a Power On
Reset (POR) circuit is implemented. Until the VCC
voltage has reached the POR threshold value, the
internal reset is active, all operations are disabled
and the device will not respond to any command.
In the same way, when VCC drops down from the
operating voltage to below the POR threshold
value, all operations are disabled and the device
will not respond to any command. A stable VCC
must be applied before applying any logic signal.
ST24LC21
SIGNAL DESCRIPTIONS
I2C Serial Clock (SCL). The SCL input pin is used
to synchronize all data in and out of the memory. A
resistor can be connected from the SCL line to VCC
to act as a pull up (see Figure 5).
Transmit Only Clock (VCLK). The VCLK input pin
is used to synchronize data out when the
ST24LC21 is in Transmit Only mode. The VCLK
input offers also a Write Enable (active high) function when the ST24LC21 is in I2C bidirectional
mode.
Serial Data (SDA). The SDA pin is bi-directional
and is used to transfer data in or out of the memory.
It is an open drain output that may be wire-OR’ed
with other open drain or open collector signals on
the bus. A resistor must be connected from the SDA
bus line to VCC to act as pull up (see Figure 5).
DEVICE OPERATION
I2C Bus Background
The ST24LC21 supports the I2C protocol. This
protocol defines any device that sends data onto
the bus as a transmitter and any device that reads
the data as a receiver. The device that controls the
data transfer is known as the master and the other
as the slave. The master will always initiate a data
transfer and will provide the serial clock for synchronisation. The ST24LC21 are always slave devices in all communications.
Start Condition. START is identified by a high to
low transition of the SDA line while the clock SCL
is stable in the high state. A START condition must
precede any command for data transfer. Except
during a programming cycle, the ST24LC21 continuously monitor the SDA and SCL signals for a
START condition and will not respond unless one
is given.
Stop Condition. STOP is identified by a low to high
transition of the SDA line while the clock SCL is
stable in the high state. A STOP condition terminates communication between the ST24LC21 and
the bus master. A STOP condition at the end of a
Read command forces the standby state. A STOP
condition at the end of a Write command triggers
the internal EEPROM write cycle.
Acknowledge Bit (ACK). An acknowledge signal
is used to indicate a successfull data transfer. The
bus transmitter, either master or slave, will release
the SDA bus after sending 8 bits of data. During the
9th clock pulse period the receiver pulls the SDA
bus low to acknowledge the receipt of the 8 bits of
data.
Figure 5. Maximum RL Value versus Bus Capacitance (CBUS) for an I2C Bus
VCC
Maximum RP value (kΩ)
20
16
RL
12
RL
SDA
MASTER
8
fc = 100kHz
4
fc = 400kHz
CBUS
SCL
CBUS
0
10
100
1000
CBUS (pF)
AI01665
5/18
ST24LC21
Table 5. Input Parameters (1) (TA = 25 °C, f = 100 kHz )
Symbol
Parameter
Test Condition
Min
Max
Unit
CIN
Input Capacitance (SDA)
8
pF
CIN
Input Capacitance (other pins)
6
pF
tLP
Low-pass filter input time constant
(SDA and SCL)
300
ns
Max
Unit
Note: 1. Sampled only, not 100% tested.
Table 6. DC Characteristics
(TA = 0 to 70 °C; VCC = 2.5V to 5.5V)
Symbol
Parameter
Test Condition
ILI
Input Leakage Current
0V ≤ VIN ≤ VCC
±2
µA
ILO
Output Leakage Current
0V ≤ VOUT ≤ VCC
SDA in Hi-Z
±2
µA
Supply Current
VCC = 5V, fC = 400kHz
(Rise/Fall time < 10ns)
2
mA
Supply Current
VCC = 2.5V, fC = 400kHz
1
mA
VIN = VSS or VCC,
VCC = 5V
100
µA
VIN = VSS or VCC,
VCC = 5V, fC = 400kHz
300
µA
VIN = VSS or VCC,
VCC = 2.5V
5
µA
VIN = VSS or VCC,
VCC = 2.5V, fC = 400kHz
50
µA
ICC
ICC1
ICC2
6/18
Supply Current (Standby)
Supply Current (Standby)
Min
VIL
Input Low Voltage (SCL, SDA)
–0.3
0.3 VCC
V
VIH
Input High Voltage (SCL, SDA)
0.7 VCC
VCC + 1
V
VIL
Input Low Voltage (VCLK)
2.5V ≤ VCC ≤ 4V
–0.3
0.2 VCC
V
VCC > 4V
–0.3
0.8
V
2
VCC + 1
V
IOL = 3mA
0.4
V
IOL = 6mA, VCC = 5V
0.6
V
VIH
Input High Voltage (VCLK)
VOL
Output Low Voltage
ST24LC21
Table 7. AC Characteristics, I2C Bidirectional Mode for Clock Frequency = 400kHz
(TA = 0 to 70 °C; VCC = 2.5V to 5.5V)
Symbol
Alt
Parameter
Min
Max
Unit
tCH1CH2
(1)
tR
Clock Rise Time
300
ns
tCL1CL2
(1)
tF
Clock Fall Time
300
ns
tDH1DH2
(1)
tR
SDA Rise Time
20
300
ns
tDL1DL2
(1)
tF
SDA Fall Time
20
300
ns
Clock High to Input Transition
600
ns
Clock Pulse Width High
600
ns
600
ns
0
µs
Clock Pulse Width Low
1.3
µs
tCHDX (2)
tSU:STA
tCHCL
tHIGH
tDLCL
tHD:STA
Input Low to Clock Low (START)
tCLDX
tHD:DAT
Clock Low to Input Transition
tCLCH
tLOW
tDXCX
tSU:DAT
Input Transition to Clock Transition
100
ns
tCHDH
tSU:STO
Clock High to Input High (STOP)
600
ns
tDHDL
tBUF
Input High to Input Low (Bus Free)
1.3
µs
tCLQV
tAA
Clock Low to Data Out Valid
200
tCLQX
tDH
Clock Low to Data Out Transition
200
fC
fSCL
Clock Frequency
400
kHz
tW
tWR
Write Time
10
ms
900
ns
ns
Notes: 1. Sampled only, not 100% tested.
2. For a reSTART condition, or following a write cycle.
Data Input. During data input the ST24LC21 sample the SDA bus signal on the rising edge of the
clock SCL. Note that for correct device operation
the SDA signal must be stable during the clock low
to high transition and the data must change ONLY
when the SCL line is low.
Memory Addressing. To start communication between the bus master and the slave ST24LC21, the
master must initiate a START condition. Following
this, the master sends onto the SDA bus line 8 bits
(MSB first) corresponding to the device select code
(7 bits) and a READ or WRITE bit. The 4 most
significant bits of the device select code are the
device type identifier, corresponding to the I2C bus
definition. For these memories the 4 bits are fixed
as 1010b. The following 3 bits are Don’t Care. The
8th bit sent is the read or write bit (RW), this bit is
set to ’1’ for read and ’0’ for write operations. If a
match is found, the corresponding memory will
acknowledge the identification on the SDA bus
during the 9th bit time.
Write Operations
Following a START condition the master sends a
device select code with the RW bit reset to ’0’. The
memory acknowledges this and waits for a byte
address. After receipt of the byte address the device again responds with an acknowledge.
In I2C bidirectional mode, any write command with
VCLK = 0 will not modify data and will be acknowledged on data bytes, as shown in Figure 11.
Byte Write. In the Byte Write mode the master
sends one data byte, which is acknowledged by the
memory. The master then terminates the transfer
by generating a STOP condition.
Page Write. The Page Write mode allows up to 8
bytes to be written in a single write cycle, provided
that they are all located in the same ’row’ in the
memory: that is the most significant memory address bits are the same. The master sends from
one up to 8 bytes of data, which are each acknowledged by the memory.
7/18
ST24LC21
Table 8. AC Characteristics, I2C Bidirectional Mode for Clock Frequency = 100kHz
(TA = 0 to 70 °C; VCC = 2.5V to 5.5V)
Symbol
Alt
tCH1CH2
tR
tCL1CL2
Max
Unit
Clock Rise Time
1
µs
tF
Clock Fall Time
300
ns
tDH1DH2
tR
Input Rise Time
1
µs
tDL1DL1
tF
Input Fall Time
300
ns
(1)
tCHDX
tSU:STA
Parameter
Min
4.7
µs
Clock Pulse Width High
4
µs
Clock High to Input Transition
tCHCL
tHIGH
tDLCL
tHD:STA
Input Low to Clock Low (START)
4
µs
tCLDX
tHD:DAT
Clock Low to Input Transition
0
µs
tCLCH
tLOW
Clock Pulse Width Low
4.7
µs
tDXCX
tSU:DAT
Input Transition to Clock Transition
250
ns
tCHDH
tSU:STO
Clock High to Input High (STOP)
4.7
µs
tDHDL
tBUF
Input High to Input Low (Bus Free)
4.7
µs
tAA
Clock Low to Next Data Out Valid
0.3
tCLQX
tDH
Data Out Hold Time
300
fC
fSCL
Clock Frequency
100
kHz
tW
tWR
Write Time
10
ms
(2)
tCLQV
3.5
µs
ns
Notes: 1. For a reSTART condition, or following a write cycle.
2. The minimum value delays the falling/rising edge of SDA away from SCL = 1 in order to avoid unwanted START and/or STOP
conditions.
Table 9. AC Characteristics, Transmit-only Mode
(TA = 0 to 70 °C; VCC = 2.5V to 5.5V)
Symbol
Alt
tVCHQX
tVAA
tVCHVCL
tVHIGH
VCLK High Time
600
ns
tVCLVCH
tVLOW
VCLK Low Time
1.3
µs
tCLQZ
tVHZ
tVPU
(1,2)
Parameter
Min
Output Valid from VCLK
Mode Tansition Time
Transmit-only Power-up Time
Max
Unit
500
ns
500
0
ns
ns
tVH1VH2
(2)
tR
VCLK Rise Time
1
µs
tVL1VL2
(2)
tF
VCLK Fall Time
1
µs
Notes: 1. Refer to Figure 3.
2. Sampled only, not 100% tested.
8/18
ST24LC21
Figure 6. AC Waveforms
tCHCL
tCLCH
SCL
tDLCL
tDXCX
tCHDH
SDA IN
tCHDX
tCLDX
START
CONDITION
tDHDL
SDA
INPUT
SDA
CHANGE
STOP &
BUS FREE
SCL
tCLQV
tCLQX
DATA VALID
SDA OUT
DATA OUTPUT
tDHDL
SCL
tW
SDA IN
tCHDH
tCHDX
STOP
CONDITION
WRITE CYCLE
tVCHVCL
START
CONDITION
tVCLVCH
VCLK
tVCHQX
SDA
tCLQZ
SCL
AI01503
9/18
ST24LC21
AC MEASUREMENT CONDITIONS
Figure 7. AC Testing Input Output Waveforms
Input Rise and Fall Times
≤ 50ns
Input Pulse Voltages SDA, SCL
0.2VCC to 0.8VCC
Input Pulse Voltages VCLK
0.4V to 2V
0.8VCC
0.7VCC
0.3VCC
0.2VCC
Input and Output Timing Ref. Voltages 0.3VCC to 0.7VCC
AI00825
Figure 8. I2C Bus Protocol
SCL
SDA
START
CONDITION
SCL
1
SDA
MSB
SDA
INPUT
2
SDA
CHANGE
STOP
CONDITION
3
7
8
9
ACK
START
CONDITION
SCL
1
SDA
MSB
2
3
7
8
9
ACK
STOP
CONDITION
AI00792
10/18
ST24LC21
Figure 9. Write Cycle Polling using ACK
WRITE Cycle
in Progress
START Condition
DEVICE SELECT
with RW = 0
NO
First byte of instruction
with RW = 0 already
decoded by ST24xxx
ACK
Returned
YES
NO
Next
Operation is
Addressing the
Memory
YES
Send
Byte Address
ReSTART
STOP
Proceed
WRITE Operation
Proceed
Random Address
READ Operation
AI01099B
DEVICE OPERATIONS (cont’d)
After each byte is transfered, the internal byte
address counter (3 least significant bits only) is
incremented. The transfer is terminated by the
master generating a STOP condition. Care must be
taken to avoid address counter ’roll-over’ which
could result in data being overwritten. Note that, for
any write mode, the generation by the master of the
STOP condition starts the internal memory program cycle. All inputs are disabled until the completion of this cycle and the memory will not respond
to any request.
Minimizing System Delays by Polling On ACK.
During the internal write cycle, the memory disconnects itself from the bus in order to copy the data
from the internal latches to the memory cells. The
maximum value of the write time (tW) is given in the
AC Characteristics table, since the typical time is
shorter, the time seen by the system may be reduced by an ACK polling sequence issued by the
master. The sequence is as follows:
– Initial condition: a Write is in progress (see Figure
9).
– Step 1: the Master issues a START condition
followed by a Device Select byte (1st byte of the
new instruction).
– Step 2: if the memory is busy with the internal
write cycle, no ACK will be returned and the
master goes back to Step 1. If the memory has
terminated the internal write cycle, it will respond
with an ACK, indicating that the memory is ready
to receive the second part of the next instruction
(the first byte of this instruction was already sent
during Step 1).
11/18
ST24LC21
Figure 10. Write Modes Sequence
VCLK
ACK
BYTE ADDR
ACK
DATA IN
STOP
DEV SEL
START
BYTE WRITE
ACK
R/W
VCLK
ACK
ACK
PAGE WRITE
START
DEV SEL
BYTE ADDR
ACK
DATA IN 1
DATA IN 2
R/W
ACK
ACK
STOP
DATA IN N
AI01504B
Read Operations
On delivery, the memory content is set at all "1’s"
(or FFh).
Current Address Read. The memory has an internal byte address counter. Each time a byte is read,
this counter is incremented. For the Current Address Read mode, following a START condition,
the master sends a memory address with the RW
bit set to ’1’. The memory acknowledges this and
outputs the byte addressed by the internal byte
address counter. This counter is then incremented.
The master does NOT acknowledge the byte out-
12/18
put, but terminates the transfer with a STOP condition.
Random Address Read. A dummy write is performed to load the address into the address
counter, see Figure 12. This is followed by another
START condition from the master and the byte
address is repeated with the RW bit set to ’1’. The
memory acknowledges this and outputs the byte
addressed. The master does NOT acknowledge
the byte output, but terminates the transfer with a
STOP condition.
ST24LC21
Figure 11. Inhibited Write when VCLK = 0
VCLK
CONTROL
BYTE
ACK
ACK
ACK
DATA n
ACK
DATA n + 1
ACK
DATA n + 7
STOP
WORD ADD n
START
DATA
ACK
CONTROL
BYTE
PAGE WRITE
ACK
STOP
WORD ADDR
START
BYTE WRITE
ACK
AI01505
Sequential Read. This mode can be initiated with
either a Current Address Read or a Random Address Read. However, in this case the master
DOES acknowledge the data byte output and the
memory continues to output the next byte in sequence. To terminate the stream of bytes, the
master must NOT acknowledge the last byte output, but MUST generate a STOP condition. The
output data is from consecutive byte addresses,
with the internal byte address counter automat-
ically incremented after each byte output. After a
count of the last memory address, the address
counter will ’roll- over’ and the memory will continue
to output data.
Acknowledge in Read Mode. In all read modes
the ST24LC21 wait for an acknowledge during the
9th bit time. If the master does not pull the SDA line
low during this time, the ST24LC21 terminate the
data transfer and switches to a standby state.
13/18
ST24LC21
Figure 12. Read Modes Sequence
ACK
DATA OUT
STOP
START
DEV SEL
NO ACK
R/W
ACK
RANDOM
ADDRESS
READ
BYTE ADDR
R/W
ACK
START
DEV SEL
DATA OUT
R/W
ACK
ACK
DATA OUT 1
NO ACK
DATA OUT N
R/W
ACK
START
DEV SEL *
ACK
BYTE ADDR
R/W
ACK
ACK
DEV SEL *
START
SEQUENTIAL
RANDOM
READ
NO ACK
STOP
SEQUENTIAL
CURRENT
READ
ACK
DEV SEL *
START
START
DEV SEL *
ACK
STOP
CURRENT
ADDRESS
READ
ACK
DATA OUT 1
R/W
NO ACK
STOP
DATA OUT N
AI00794C
Note: * The 7 Most Significant bits of DEV SEL bytes of a Random Read (1st byte and 3rd byte) must be identical.
14/18
ST24LC21
ORDERING INFORMATION SCHEME
Example:
ST24LC21
Package
B
PSDIP8
0.25mm Frame
M
SO8
M
1
TR
Temperature Range
1
0 to 70 °C
Option
TR Tape & Reel
Packing
Devices are shipped from the factory with the memory content set at all "1’s" (FFh).
For a list of available options (Package, etc...) or for further information on any aspect of this device, please
contact the SGS-THOMSON Sales Office nearest to you.
15/18
ST24LC21
PSDIP8 - 8 pin Plastic Skinny DIP, 0.25mm lead frame
mm
Symb
Typ
inches
Min
Max
A
3.90
A1
Min
Max
5.90
0.154
0.232
0.49
–
0.019
–
A2
3.30
5.30
0.130
0.209
B
0.36
0.56
0.014
0.022
B1
1.15
1.65
0.045
0.065
C
0.20
0.36
0.008
0.014
D
9.20
9.90
0.362
0.390
–
–
–
–
6.00
6.70
0.236
0.264
–
–
–
–
7.80
–
0.307
–
E
7.62
E1
e1
2.54
eA
eB
Typ
0.300
0.100
10.00
L
3.00
N
8
0.394
3.80
0.118
8
PSDIP8
A2
A1
B
A
L
e1
eA
eB
B1
D
C
N
E1
E
1
PSDIP-a
Drawing is not to scale
16/18
0.150
ST24LC21
SO8 - 8 lead Plastic Small Outline, 150 mils body width
mm
Symb
Typ
inches
Min
Max
A
1.35
A1
Min
Max
1.75
0.053
0.069
0.10
0.25
0.004
0.010
B
0.33
0.51
0.013
0.020
C
0.19
0.25
0.007
0.010
D
4.80
5.00
0.189
0.197
E
3.80
4.00
0.150
0.157
–
–
–
–
H
5.80
6.20
0.228
0.244
h
0.25
0.50
0.010
0.020
L
0.40
0.90
0.016
0.035
α
0°
8°
0°
8°
N
8
e
1.27
CP
Typ
0.050
8
0.10
0.004
SO8
h x 45˚
A
C
B
CP
e
D
N
E
H
1
A1
α
L
SO-a
Drawing is not to scale
17/18
ST24LC21
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsibility for the
consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No
license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specifications mentioned
in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.
SGS-THOMSON Microelectronics products are not authorized for use as critical components in life support devices or systems without express
written approval of SGS-THOMSON Microelectronics.
© 1997 SGS-THOMSON Microelectronics - All Rights Reserved
Purchase of I2C Components by SGS-THOMSON Microelectronics, conveys a license under the Philips
I2C Patent. Rights to use these components in an I2C system, is granted provided that the system conforms to
the I2C Standard Specifications as defined by Philips.
SGS-THOMSON Microelectronics GROUP OF COMPANIES
Australia - Brazil - Canada - China - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A.
18/18