FUJI EDSX6-95F

PORTABLE TYPE
ULTRASONIC FLOWMETER
FLC...2, FLD
DATA SHEET
PORTAFLOW-X is a portable type ultrasonic flowmeter
utilizing transit time difference for measuring flow rates in
pipes from the outside. It is a compact and light-weight instrument incorporating
the latest electronics and digital signal processing technologies, realizing high performance and easy operation.
FEATURES
1. Compact and light-weight
The adoption of the latest electronics and digital signal
processing technologies has reduced the size and
weight of the converter to 1/7 and 1/5, respectively, in
comparison with traditional model.
2. Battery operation
This flowmeter is designed for 5 hours of continuous
operation with its own built-in battery which is rechargeable in 2 hours with the supplied power adaptor.
3. Full variety of sensors
The flowmeter can be used with various types of sensors applicable for small to large diameter pipe (φ13 to
φ6000) and low to high temperature (–40 to +200°C).
4. High accuracy
The flowmeter is designed for high accuracy (± 1.0%).
The adoption of new sound velocity measurement system permits measurements of fluids of unknown sound
velocity, and also slightly affection from fluid temperature and pressure.
5. Improvement in anti-bubble characteristic
Anti-bubble characteristic is greatly improved by digital
signal processing.
6. Quick response
With the use of high-speed micro-processor suited for
digital signal processing, the response time is at fast as
1 second or less.
7. Multi-lingual
The following languages are supported for display: Japanese (katakana), English, German and French.
8. Excellent performance and easy operation
Large type graphic LCD and minimum number of function keys are used for page selection, allowing easy setting.
– LCD with back light
– Equipped with 40000 data logging function of 20 sites
– Equipped with received wave monitoring function
– Equipped with serial communication function
– Easy mounting of sensor
– Integrated type graphic printer (option)
Detector (Type: FLD12)
Converter (Type: FLC)
SPECIFICATIONS
Fluid conditions
Measured fluid: Homogeneous liquids (water, sea water,
oil or fluid of unknown sound velocity)
capable of ultrasonic wave propagation
Turbidity of fluid: 10000 deg. (mg/ℓ) or less
State of flow: Axis-symmetric flow in pipe filled with fluid
Fluid temperature:
Small diameter sensor, – 40 to +100°C
Small sensor, [Standard] – 40 to +100°C
Middle sensor, – 40 to +8°C
Large sensor, – 40 to +80°C
High-temperature sensor, – 40 to +200°C
Velocity range:
– 32 to 0 to +32m/s
Piping conditions
Pipe material: Steel, stainless steel, cast iron, vinylchloride, FRP, asbestos, aluminum,
acrylic, etc.
Pipe size: Small diameter sensor, φ13 to φ100
Small sensor, φ50 to φ400
Middle sensor, φ200 to φ1200
Large sensor, φ200 to φ6000
High-temperature sensor, φ50 to φ400
Lining material: None, tar epoxy, mortar, rubber or material of known sound velocity
Straight pipe length:
Upstream side, 10D or more
Downstream side, 5D or more (D: inner
pipe diameter)
Refer to Japan Electric Measuring Instruments Manufactures’ Association’s
standard JEMIS-032 for details.
EDSX6-95f
Date
May. 8, 2006
FLC...2, FLD
Accuracy
Pipe size
φ13 to
φ50 or less
φ50 to
φ300 or less
φ300 to
φ6000
Flow velocity
Accuracy
2 to32m/s
1.5% of rate
0 to 2m/s
0.03m/s
2 to32m/s
1.0% of rate
0 to 2m/s
0.02m/s
1 to32m/s
1.0% of rate
0 to 1m/s
0.01m/s
(Note)Reference conditions are based
on JEMIS-032.
Converter (Type:FLC)
Built-in battery or power adaptor
Special type Ni-MH battery
Continuous operation time, about 5
hours (without printer, back light OFF,
analog output OFF, trans voltage 1 time)
Recharging time, about 2 hours (power
adaptor used)
Power adaptor: Special type power adaptor 90 to 264V
AC, 47 to 63Hz or 10 to 30V DC
Power consumption:
12W or less
LCD display:
Full dot graphic display
240 x 320 dot (with back light)
LED display: DC IN (green), FAST CHARGE (red)
Key pad:
10 keys (ON, OFF, r, s, w, v, ESC,
ENT, LIGHT, PRINT)
Power failure backup:
Memory backup with lithium battery
(effective term, 5 years)
Response time: 1s or less
Output signal:
4 to 20mA DC, 1 point (load resistance,
0 to 1kW)
Input signal:
4 to 20mA DC (not isolated), 1 point
Serial communication:
RS-232C (not isolated), 1 point
Transmission speed: Max. 9600BPS
Transmission distance: Max. 15m
Printer (option): To be mounted on top of converter
Thermal serial dot printing (8 x 256 dot)
Ambient temperature:
–10 to +55°C (without printer)
–10 to +45°C (with printer)
Ambient humidity:
90% RH or less
Type of enclosure:
Dust-proof type (IP50 or equivalent)
Enclosure case: Plastic case (color: gray)
Dimensions:
H240 x W127 x D70mm (without printer)
H359 x W127 x D70mm (with printer)
Mass: 1.5kg (without printer)
2.0kg (with printer)
Power supply:
Built-in battery:
Detector (Type: FLD)
Mounting method:
Mounting on outside of already constructed pipe
Sensor mounting method:
V or Z method
Mounting belt /wire:
Small diameter sensor, plastic cloth belt
Small sensor, plastic cloth belt
Middle sensor, stainless wire
Large sensor, stainless wire
High-temperature sensor, stainless belt
Acoustic coupler: Silicone grease
Signal cable:
Special type coaxial cable
Connection:
Converter; BNC connector
Sensor, middle/large type; terminal screws
Other; BNC connector
Ambient temperature:
–20 to +60°C
Ambient humidity:
Middle/large sensor, 100% RH or less
Other, 90% RH or less
Type of enclosure:
Middle/large sensor, immersion-proof
type
(IP67 or equivalent)
Other, drip-proof type
(IP52 or equivalent)
Material:
Kind
Sensor case
Small diameter
Small type
Middle type
Large type
High temperature
Plastic
Plastic
Plastic
Plastic
304SS
Mounting bracket
Aluminum alloy + Plastic
Aluminum alloy + Plastic
—
—
Aluminum alloy + 304SS
Dimensions/mass:
Kind
Small diameter
Small type
Middle type
Large type
High temperature
Dimensions (HxWxD)
420 x 53 x 90mm
540 x 53 x 90mm
72 x 60 x 40mm
104 x 93 x 62mm
530 x 52 x 205mm
Note: mass of both sensors
Mass
0.6kg
0.8kg
0.4kg (Note)
1.4kg (Note)
1.7kg
MEASURING PRINCIPLE
With ultrasonic pulses propagated diagonally between the
upstream and downstream sensors, flow rate is measured
by detecting the time difference obtained by the flow of
fluid.
Detector
Upstreamsensor
q
Flow
velocityV
t1
D
t2
Output
Con- signal
verter
Downstreamsensor
MOUNTING OF DETECTOR
PZToscillator
Plasticwedge
Pipe
Lining
CONFIGURATION DIAGRAM
(1) Single-measuring-path system (V method)
Cable
Detector
Converter
Display language:Japanese (Katakana) / English / German/
French, selectable
Instantaneous value display function:
Two of velocity, flow rate (with flow direction) and analog input, simultaneous
display
Unit; Metric/English system selectable
Metric system:
Velocity m/s
Flow rate ℓ/s, ℓ/min, ℓ/h, Mℓ/d, m3 /s,
m3 /min, m3 /h, Mm3 /d, BBL/s,
BBL/min, BBL/h, MBBL/d
English system:
Velocity ft/s
Flow rate gal/s, gal/min, gal/h, Mgal/d,
ft3/s, ft3/min, ft3/h, Mft3/d, BBL/s,
BBL/min, BBL/h, MBBL/d
Note: Gal refers to U.S. gallons.
Total value display function:
Forward and reverse total values, simultaneous display
Unit; Metric/English system, selectable
Metric system: mℓ, ℓ, m3, km3, Mm3
mBBL, BBL, KBBL
English system: gal, kgal, ft3, kft3, Mft3
mBBL, BBL, KBBL
Clock display function:
Time (year, month, day, hour, minute)
display and setting
Damping: 0 to 99s (time constant)
Low flow cut:
0 to 1.000m/s 0 to 3.300 ft/s
Output setting function:
Current output scaling, output type,
burnout setting and calibration
Communication function:
Velocity, flow rate, totals, analog input,
status, logging data transmission on request
Logging function:Site data (place, piping, fluid, sensor
mounting method, type of sensor) up
to 20 places and a maximum of 40000
data (time, velocity, flow rate, totals,
analog input, status) can be stored in
memory.
Waveform display function:
Display of bi-directional received waveforms
Graph display function:
Display of velocity, flow rate or analog
input trend graph
Printing function: Printout of screen, fixed cycle printout
(time, velocity, flow rate, totals, analog
input, status), logging data, trend graph,
and waveforms by using integral printer
(option)
DC
4~20mA
(2) Single-measuring-path system (Z method)
Cable
Detector
Converter
Functions
DC
4~20mA
FLC...2, FLD
CODE SYMBOLS
<Converter>
<Detector>
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
F L C
0
Description
2
F LD
Specification
Standard
S
1
2
3
4
5
Converter
Basicsystem
Basicsystem+Printer
1
2
Power adapter
ACpower(90to264VAC,50/60Hz)
1
9
Description
1
Kind
Smallsensor(standard)
Smalldiametersensor
High-temperaturesensor
Middlesensor
Largesensor
2
2
2
1
1
Terminal mold
None
Provided(Middle/Largesensoronly)
0
1
Note:DCpoweradapterisoptionalaccesoories.
Structure
Generaluse
Y
A
T h e p ro d u c t c o n fo r m s t o t h e re q u i re m e n t s o f t h e
Electromagnetic compatibility Directive 89/336/EEC as
detailed within the technical construction file number
TN510423. The applicable standards used to demonstrate
compliance are :-
Coaxial cable
5m
EN 55011:1991
Conducted and Radiated emissions
CLASS A
EN 50082-1 :-1992
Radiated immunity, ESD and FBT
DETECTOR SELECTION GUIDE
Fluidtemperature( C)
200
High-temperature
sensor
Middlesensor
100
Standard
sensor
(smalltype)
80
Small
diameter
sensor
Large
sensor
0
–40
13
50
100
200
400
1200
[Note]
1. High turbid fluid or scales sticking on the internal wall of
pipes may interrupt the ultrasonic propagations.
2. In case of cast iron pipes or pipes with lining, the Large
sensor is recommended rather than the Middle sensor.
6000
Pipesize(mm)
SCOPE OF DELIVERY
Converter (Type: FLC)
Name of unit
1 Basic system
Detector (Type: FLD)
Scope of delivery
Name of unit
1) Converter unit
2) Power adaptor
3) Power cable (2m)
4) Analog input/output cable (1.5m)
5) Carrying case
6) Manual
1 Small diameter/small/
middle / large / high
temperature
Scope of delivery
1) Sensor unit
2) Signal cable (5m, 2 cables)
3) Mounting belt/wire
4) Silicone grease (100g)
(Note) Small sensor and small diameter sensor can be put in the
basic system carrying case.
1) Printer unit
2) Roll paper (1 roll)
2 Printer
OPTIONAL ACCESSORIES
Item
Specification
Drawing No.
1 Battery
Special type Ni-MH battery (12V, 1350mAh)
TK7M7039C1
2 Power adaptor
Special type power adaptor, with power cable, 2m
90 to 264V AC, 47 to 63Hz
10 to 30V DC (with car cigarette cable)
TK7G7976C1
TK7G7977C1
3 Printer unit
Mounted on top of converter, with roll paper (1 roll),
Thermal serial dot system (8 x 256 dot)
TK7G7978C1
4 Printer roll paper
Maker: SEIKO I
Type: TP080–20LJ1
Specification:
thermal roll paper,
80mm wide x φ40, without core
TK7G7982C1
5 Silicone grease
Maker: Shin-Etsu
Type:Standard G40M, 100g
High temperature KS62M, 100g
TK7G7984C1
TK7G7983C1
Special type signal cable, 5m x 2
Middle/large sensor; BNC connector on one side
Other: BNC connector on both sides
TK468664C5
TK7G7987C1
Special type coaxial cable with BNC connector
10m x 2
50m x 2
TK468664C3
TK468664C4
6 Signal cable
7 Extension signal cable
8 Analog input/output cable 4-core cable, 1.5m, with connector
TK7G7974C1
9 Mounting belt/wire
Small/small diameter sensor:plastic cloth belt
Middle sensor: stainless wire
Large sensor:
stainless wire
High-temperature sensor: stainless belt
TK7G7979C1
TK7G7980C3
TK7G7980C5
TK7G7981C1
10 Pipe thickness gauge
Maker: Kawatetsu Advantech
Type: TI–50K
Specification:Material;copper, c ast iron, aluminum,
glass, hard resin, ceramic, etc.
Measuring range; 0.8 to 80mm
Accuracy; ±0.1mm or 0.5% RD
TI-50K
FLC...2, FLD
OUTLINE DIAGRAM (Unit:mm)
Sensorinput(upstream)
127
70
Sensorinput(downstream)
127
70
DOWN STREAM
Sensorinput
(downstream)
OFF
ENT
DOWN STREAM
SENSOR
DC17.5V
SERIAL
ON
Sensorinput
(upstream)
UP STREAM
359
UP STREAM
DC
powerinput
ANALOG
IN/OUT
240
SENSOR
OFF
ON
FEED
Printer
DCpowerinput
LIGHT
ANALOG
IN/OUT
PRINT
ESC
SERIAL
DC17.5V
FAST CHARGE DC IN
ON
OFF
ENT
LIGHT
Serialcommunication
port
Powerswitch
PRINT
ESC
FAST CHARGE DC IN
Analog
input/output
Serialcommunicationport
Powerswitch
Converter FLCS1
Analoginput/output
Converter FLC2 (with printer)
Saddle
Scale(inch)
Saddle
Scale(mm)
Scale(inch)
Scale(mm)
Locknut
Cursor
320
Distancebetween
twosensors0~128
BNCconnector
540
Distancebetween
twosensors0~335
BNCconnector
Locknut
Elementholder
Cursor
36
90max
Elementholder
36
90max
52.5
Detector FLD12 (small sensor)
52.5
Detector FLD22 (small diameter sensor)
Scale(inch)
Scale(mm)
33
Saddle
Distancebetween
twosensors0~330
72
BNCconnector
114
530
Detector
Cable(Length:5m)
Locknut
Grandterminal
Wirerope
33
19
Cursor
BNCConnecter
Mountingspring
60
40
Elementholder
33
90max
205max
f26
Detector FLD41 (middle sensor)
52
Detector FLD32 (high-temperature sensor)
104
EXTERNAL CONNECTION DIAGRAM
Serial communication
6
114
93
Sensor unit
9
1
Cable(5mlong)
Wirerope
f 19
62
BNCconnector
Mountingspring
Sensor input/output
Upstream side
CONNECTOR :
D-SUB 9 Pin
Plug (male)
5
Pin No.
Symbol
Item
1
2
3
4
5
6
7
8
9
­­—
RxD
TxD
DTR
GND
DSR
RTS
CTS
—
—
Receive data
Send data
Data terminal ready
Signal ground
Data set ready
Send request
Send ready
—
Downstream side
Detector FLD51 (large sensor)
FLC,FLD-P6-C
Power input
(power adaptor output)
Analog input/output
4
3
2
1
CONNECTOR :
Circular
connector
4 pin
DC17.5V
FLD,FLC-P6-E
Pin No.
Item
Color
1
2
3
4
Analog input +
Analog output –
Analog input –
Analog output +
Black
Red
White
Blue
FLD,FLC-P6-E
FLC...2, FLD
CautiononSafety
*Beforeusingthisproduct,besuretoreaditsinstructionmanualinadvance.
Head Office
GateCityOhsaki,EastTower,11-2,Osaki1-chome,
Shinagawa-ku,Tokyo141-0032,Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1,Fuji-machi,Hino-city,Tokyo,191-8502Japan
Phone:81-42-585-6201,6202Fax:81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.