PORTABLE TYPE ULTRASONIC FLOWMETER FLC...2, FLD DATA SHEET PORTAFLOW-X is a portable type ultrasonic flowmeter utilizing transit time difference for measuring flow rates in pipes from the outside. It is a compact and light-weight instrument incorporating the latest electronics and digital signal processing technologies, realizing high performance and easy operation. FEATURES 1. Compact and light-weight The adoption of the latest electronics and digital signal processing technologies has reduced the size and weight of the converter to 1/7 and 1/5, respectively, in comparison with traditional model. 2. Battery operation This flowmeter is designed for 5 hours of continuous operation with its own built-in battery which is rechargeable in 2 hours with the supplied power adaptor. 3. Full variety of sensors The flowmeter can be used with various types of sensors applicable for small to large diameter pipe (φ13 to φ6000) and low to high temperature (–40 to +200°C). 4. High accuracy The flowmeter is designed for high accuracy (± 1.0%). The adoption of new sound velocity measurement system permits measurements of fluids of unknown sound velocity, and also slightly affection from fluid temperature and pressure. 5. Improvement in anti-bubble characteristic Anti-bubble characteristic is greatly improved by digital signal processing. 6. Quick response With the use of high-speed micro-processor suited for digital signal processing, the response time is at fast as 1 second or less. 7. Multi-lingual The following languages are supported for display: Japanese (katakana), English, German and French. 8. Excellent performance and easy operation Large type graphic LCD and minimum number of function keys are used for page selection, allowing easy setting. – LCD with back light – Equipped with 40000 data logging function of 20 sites – Equipped with received wave monitoring function – Equipped with serial communication function – Easy mounting of sensor – Integrated type graphic printer (option) Detector (Type: FLD12) Converter (Type: FLC) SPECIFICATIONS Fluid conditions Measured fluid: Homogeneous liquids (water, sea water, oil or fluid of unknown sound velocity) capable of ultrasonic wave propagation Turbidity of fluid: 10000 deg. (mg/ℓ) or less State of flow: Axis-symmetric flow in pipe filled with fluid Fluid temperature: Small diameter sensor, – 40 to +100°C Small sensor, [Standard] – 40 to +100°C Middle sensor, – 40 to +8°C Large sensor, – 40 to +80°C High-temperature sensor, – 40 to +200°C Velocity range: – 32 to 0 to +32m/s Piping conditions Pipe material: Steel, stainless steel, cast iron, vinylchloride, FRP, asbestos, aluminum, acrylic, etc. Pipe size: Small diameter sensor, φ13 to φ100 Small sensor, φ50 to φ400 Middle sensor, φ200 to φ1200 Large sensor, φ200 to φ6000 High-temperature sensor, φ50 to φ400 Lining material: None, tar epoxy, mortar, rubber or material of known sound velocity Straight pipe length: Upstream side, 10D or more Downstream side, 5D or more (D: inner pipe diameter) Refer to Japan Electric Measuring Instruments Manufactures’ Association’s standard JEMIS-032 for details. EDSX6-95f Date May. 8, 2006 FLC...2, FLD Accuracy Pipe size φ13 to φ50 or less φ50 to φ300 or less φ300 to φ6000 Flow velocity Accuracy 2 to32m/s 1.5% of rate 0 to 2m/s 0.03m/s 2 to32m/s 1.0% of rate 0 to 2m/s 0.02m/s 1 to32m/s 1.0% of rate 0 to 1m/s 0.01m/s (Note)Reference conditions are based on JEMIS-032. Converter (Type:FLC) Built-in battery or power adaptor Special type Ni-MH battery Continuous operation time, about 5 hours (without printer, back light OFF, analog output OFF, trans voltage 1 time) Recharging time, about 2 hours (power adaptor used) Power adaptor: Special type power adaptor 90 to 264V AC, 47 to 63Hz or 10 to 30V DC Power consumption: 12W or less LCD display: Full dot graphic display 240 x 320 dot (with back light) LED display: DC IN (green), FAST CHARGE (red) Key pad: 10 keys (ON, OFF, r, s, w, v, ESC, ENT, LIGHT, PRINT) Power failure backup: Memory backup with lithium battery (effective term, 5 years) Response time: 1s or less Output signal: 4 to 20mA DC, 1 point (load resistance, 0 to 1kW) Input signal: 4 to 20mA DC (not isolated), 1 point Serial communication: RS-232C (not isolated), 1 point Transmission speed: Max. 9600BPS Transmission distance: Max. 15m Printer (option): To be mounted on top of converter Thermal serial dot printing (8 x 256 dot) Ambient temperature: –10 to +55°C (without printer) –10 to +45°C (with printer) Ambient humidity: 90% RH or less Type of enclosure: Dust-proof type (IP50 or equivalent) Enclosure case: Plastic case (color: gray) Dimensions: H240 x W127 x D70mm (without printer) H359 x W127 x D70mm (with printer) Mass: 1.5kg (without printer) 2.0kg (with printer) Power supply: Built-in battery: Detector (Type: FLD) Mounting method: Mounting on outside of already constructed pipe Sensor mounting method: V or Z method Mounting belt /wire: Small diameter sensor, plastic cloth belt Small sensor, plastic cloth belt Middle sensor, stainless wire Large sensor, stainless wire High-temperature sensor, stainless belt Acoustic coupler: Silicone grease Signal cable: Special type coaxial cable Connection: Converter; BNC connector Sensor, middle/large type; terminal screws Other; BNC connector Ambient temperature: –20 to +60°C Ambient humidity: Middle/large sensor, 100% RH or less Other, 90% RH or less Type of enclosure: Middle/large sensor, immersion-proof type (IP67 or equivalent) Other, drip-proof type (IP52 or equivalent) Material: Kind Sensor case Small diameter Small type Middle type Large type High temperature Plastic Plastic Plastic Plastic 304SS Mounting bracket Aluminum alloy + Plastic Aluminum alloy + Plastic — — Aluminum alloy + 304SS Dimensions/mass: Kind Small diameter Small type Middle type Large type High temperature Dimensions (HxWxD) 420 x 53 x 90mm 540 x 53 x 90mm 72 x 60 x 40mm 104 x 93 x 62mm 530 x 52 x 205mm Note: mass of both sensors Mass 0.6kg 0.8kg 0.4kg (Note) 1.4kg (Note) 1.7kg MEASURING PRINCIPLE With ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. Detector Upstreamsensor q Flow velocityV t1 D t2 Output Con- signal verter Downstreamsensor MOUNTING OF DETECTOR PZToscillator Plasticwedge Pipe Lining CONFIGURATION DIAGRAM (1) Single-measuring-path system (V method) Cable Detector Converter Display language:Japanese (Katakana) / English / German/ French, selectable Instantaneous value display function: Two of velocity, flow rate (with flow direction) and analog input, simultaneous display Unit; Metric/English system selectable Metric system: Velocity m/s Flow rate ℓ/s, ℓ/min, ℓ/h, Mℓ/d, m3 /s, m3 /min, m3 /h, Mm3 /d, BBL/s, BBL/min, BBL/h, MBBL/d English system: Velocity ft/s Flow rate gal/s, gal/min, gal/h, Mgal/d, ft3/s, ft3/min, ft3/h, Mft3/d, BBL/s, BBL/min, BBL/h, MBBL/d Note: Gal refers to U.S. gallons. Total value display function: Forward and reverse total values, simultaneous display Unit; Metric/English system, selectable Metric system: mℓ, ℓ, m3, km3, Mm3 mBBL, BBL, KBBL English system: gal, kgal, ft3, kft3, Mft3 mBBL, BBL, KBBL Clock display function: Time (year, month, day, hour, minute) display and setting Damping: 0 to 99s (time constant) Low flow cut: 0 to 1.000m/s 0 to 3.300 ft/s Output setting function: Current output scaling, output type, burnout setting and calibration Communication function: Velocity, flow rate, totals, analog input, status, logging data transmission on request Logging function:Site data (place, piping, fluid, sensor mounting method, type of sensor) up to 20 places and a maximum of 40000 data (time, velocity, flow rate, totals, analog input, status) can be stored in memory. Waveform display function: Display of bi-directional received waveforms Graph display function: Display of velocity, flow rate or analog input trend graph Printing function: Printout of screen, fixed cycle printout (time, velocity, flow rate, totals, analog input, status), logging data, trend graph, and waveforms by using integral printer (option) DC 4~20mA (2) Single-measuring-path system (Z method) Cable Detector Converter Functions DC 4~20mA FLC...2, FLD CODE SYMBOLS <Converter> <Detector> 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 F L C 0 Description 2 F LD Specification Standard S 1 2 3 4 5 Converter Basicsystem Basicsystem+Printer 1 2 Power adapter ACpower(90to264VAC,50/60Hz) 1 9 Description 1 Kind Smallsensor(standard) Smalldiametersensor High-temperaturesensor Middlesensor Largesensor 2 2 2 1 1 Terminal mold None Provided(Middle/Largesensoronly) 0 1 Note:DCpoweradapterisoptionalaccesoories. Structure Generaluse Y A T h e p ro d u c t c o n fo r m s t o t h e re q u i re m e n t s o f t h e Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510423. The applicable standards used to demonstrate compliance are :- Coaxial cable 5m EN 55011:1991 Conducted and Radiated emissions CLASS A EN 50082-1 :-1992 Radiated immunity, ESD and FBT DETECTOR SELECTION GUIDE Fluidtemperature( C) 200 High-temperature sensor Middlesensor 100 Standard sensor (smalltype) 80 Small diameter sensor Large sensor 0 –40 13 50 100 200 400 1200 [Note] 1. High turbid fluid or scales sticking on the internal wall of pipes may interrupt the ultrasonic propagations. 2. In case of cast iron pipes or pipes with lining, the Large sensor is recommended rather than the Middle sensor. 6000 Pipesize(mm) SCOPE OF DELIVERY Converter (Type: FLC) Name of unit 1 Basic system Detector (Type: FLD) Scope of delivery Name of unit 1) Converter unit 2) Power adaptor 3) Power cable (2m) 4) Analog input/output cable (1.5m) 5) Carrying case 6) Manual 1 Small diameter/small/ middle / large / high temperature Scope of delivery 1) Sensor unit 2) Signal cable (5m, 2 cables) 3) Mounting belt/wire 4) Silicone grease (100g) (Note) Small sensor and small diameter sensor can be put in the basic system carrying case. 1) Printer unit 2) Roll paper (1 roll) 2 Printer OPTIONAL ACCESSORIES Item Specification Drawing No. 1 Battery Special type Ni-MH battery (12V, 1350mAh) TK7M7039C1 2 Power adaptor Special type power adaptor, with power cable, 2m 90 to 264V AC, 47 to 63Hz 10 to 30V DC (with car cigarette cable) TK7G7976C1 TK7G7977C1 3 Printer unit Mounted on top of converter, with roll paper (1 roll), Thermal serial dot system (8 x 256 dot) TK7G7978C1 4 Printer roll paper Maker: SEIKO I Type: TP080–20LJ1 Specification: thermal roll paper, 80mm wide x φ40, without core TK7G7982C1 5 Silicone grease Maker: Shin-Etsu Type:Standard G40M, 100g High temperature KS62M, 100g TK7G7984C1 TK7G7983C1 Special type signal cable, 5m x 2 Middle/large sensor; BNC connector on one side Other: BNC connector on both sides TK468664C5 TK7G7987C1 Special type coaxial cable with BNC connector 10m x 2 50m x 2 TK468664C3 TK468664C4 6 Signal cable 7 Extension signal cable 8 Analog input/output cable 4-core cable, 1.5m, with connector TK7G7974C1 9 Mounting belt/wire Small/small diameter sensor:plastic cloth belt Middle sensor: stainless wire Large sensor: stainless wire High-temperature sensor: stainless belt TK7G7979C1 TK7G7980C3 TK7G7980C5 TK7G7981C1 10 Pipe thickness gauge Maker: Kawatetsu Advantech Type: TI–50K Specification:Material;copper, c ast iron, aluminum, glass, hard resin, ceramic, etc. Measuring range; 0.8 to 80mm Accuracy; ±0.1mm or 0.5% RD TI-50K FLC...2, FLD OUTLINE DIAGRAM (Unit:mm) Sensorinput(upstream) 127 70 Sensorinput(downstream) 127 70 DOWN STREAM Sensorinput (downstream) OFF ENT DOWN STREAM SENSOR DC17.5V SERIAL ON Sensorinput (upstream) UP STREAM 359 UP STREAM DC powerinput ANALOG IN/OUT 240 SENSOR OFF ON FEED Printer DCpowerinput LIGHT ANALOG IN/OUT PRINT ESC SERIAL DC17.5V FAST CHARGE DC IN ON OFF ENT LIGHT Serialcommunication port Powerswitch PRINT ESC FAST CHARGE DC IN Analog input/output Serialcommunicationport Powerswitch Converter FLCS1 Analoginput/output Converter FLC2 (with printer) Saddle Scale(inch) Saddle Scale(mm) Scale(inch) Scale(mm) Locknut Cursor 320 Distancebetween twosensors0~128 BNCconnector 540 Distancebetween twosensors0~335 BNCconnector Locknut Elementholder Cursor 36 90max Elementholder 36 90max 52.5 Detector FLD12 (small sensor) 52.5 Detector FLD22 (small diameter sensor) Scale(inch) Scale(mm) 33 Saddle Distancebetween twosensors0~330 72 BNCconnector 114 530 Detector Cable(Length:5m) Locknut Grandterminal Wirerope 33 19 Cursor BNCConnecter Mountingspring 60 40 Elementholder 33 90max 205max f26 Detector FLD41 (middle sensor) 52 Detector FLD32 (high-temperature sensor) 104 EXTERNAL CONNECTION DIAGRAM Serial communication 6 114 93 Sensor unit 9 1 Cable(5mlong) Wirerope f 19 62 BNCconnector Mountingspring Sensor input/output Upstream side CONNECTOR : D-SUB 9 Pin Plug (male) 5 Pin No. Symbol Item 1 2 3 4 5 6 7 8 9 — RxD TxD DTR GND DSR RTS CTS — — Receive data Send data Data terminal ready Signal ground Data set ready Send request Send ready — Downstream side Detector FLD51 (large sensor) FLC,FLD-P6-C Power input (power adaptor output) Analog input/output 4 3 2 1 CONNECTOR : Circular connector 4 pin DC17.5V FLD,FLC-P6-E Pin No. Item Color 1 2 3 4 Analog input + Analog output – Analog input – Analog output + Black Red White Blue FLD,FLC-P6-E FLC...2, FLD CautiononSafety *Beforeusingthisproduct,besuretoreaditsinstructionmanualinadvance. Head Office GateCityOhsaki,EastTower,11-2,Osaki1-chome, Shinagawa-ku,Tokyo141-0032,Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1,Fuji-machi,Hino-city,Tokyo,191-8502Japan Phone:81-42-585-6201,6202Fax:81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. PrintedinJapan