FUJI EDS6-123I

ULTRASONIC FLOWMETER < M-Flow PW>
FLR, FLS, FLY
DATA SHEET
This meter is a clamp-on type ultrasonic flowmeter for
permanent use based on transit time measuring method. The M-Flow PW is ideal for clean liquids containing no air
bubbles such as pure water. The easy-to-use compact and
lightweight design is intended for integration into mechanical devices. The flowmeter applicable to small and medium
size pipes of diameter range from 25mm to 600mm provides superior cost performance.
FEATURES
1. Ease of use:
The detector (type: FLSE 2) is mountable quickly and
easily.
The parameters necessary for measurement can be
configured on the surface of Flow Transmitter’s housing
case by menu-driven software.
2. Compact and light weight:
The adoption of the latest electronics technology has reduced the size and weight of the flow transmitter to onefifth of our general use flow transmitter.
3. Superior temperature effect:
The adoption of Sound Velocity Measurement System,
which calculates sound velocity from transit time, keeps
the flowmeter unaffected by the temperature and the
pressure of the fluid to be measured.
4. Quick response:
With the use of fast-speed transit time processor, the
system cycle is 0.2 sec that is applicable to short batch
process.
5. Multilingual:
The following languages are supported for display: English, Japanese, French, German and Spanish
6. Synchronization (option):
Simultaneous transmission to two or more converters is
allowed.
Cross-talk between flowmeters located closely or acoustic interference between flowmeters installed on the
same pipe line can be removed by using this synchronization function of transmission timing of ultrasonic
waves. SPECIFICATIONS
Operational specifications
System configuration:
The system is composed of a detector (Model
FLS) and a flow transmitter (Model FLR), realizing single-path system.
Flow Transmitter (FLR)
Detector (FLSE12)
(FLSE22)
Detector (FLSE31)
Detector (FLSE41)
Application: Clean liquids that pass ultrasound and do not
contain air bubbles (such as pure water and
chemical solution)
Turbidity: 10000deg (mg/L) or less
Fluid temperature (Continuous use rating):
-20 to +100deg°C (type: FLSE 2 3-Y)
0 to +120deg°C (type: FLSE 2 3-A)
-20 to +80deg°C (type: FLSE 1)
With silicon rubber
for acoustic couplant
0 to +60deg°C
With silicon-free grease
for acoustic couplant
Type of flow:Well-developed turbulent or
laminar flow in a full-filled pipe
(
(
)
)
EDS6-123i
Date
Apr. 1, 2011
FLR, FLS, FLY
Applicable flow pipe:
Internal pipe
Detector diameter
FLSE12 ø25 to
ø100mm
ø50 to
ø100mm
FLSE22 ø50 to
ø225mm
Note 3
FLSE31 ø50 to
ø300mm
FLSE41 ø300 to
ø600mm
Performance specifications
Pipe material
Plastic (PVC, etc.)
Note 1
Metal (stainless
steel, steel, copper,
aluminum, etc.)
Plastic (PVC, etc.)
Note 1
Metal (stainless
steel, steel, copper,
aluminum, etc.)
Note 2
Plastic
(PVC, PP, PVDF, etc.)
Metal (stainless
steel, steel, copper,
aluminum, etc.)
Note 2
Installation Fluid temperature
method
range
Plastic pipe
V
9th digit in code
symbol
Y...-20 to +100°C
A...0 to +120°C
V
-20 to 80C
Z
Liner: Tar epoxy, mortar, rubber, and others
Fundamental straight pipe:
10D for upstream and 5D for downstream (D: internal pipe diameter)
Refer to “Conditions on straight pipe”
for details.
Velocity:
0 to ±0.3 ... ±10m/s
Power supply:100 to 120V AC ±10%, 50/60Hz or 200 to
240V AC ±10%, 50/60Hz or 20 to 30V DC
Signal cable: Co-axial cable up to 30m and thermal stability of 100 deg.C
Environment: Non-explosive environment without direct
sunlight, corrosive gas and heat radiation
Ambient temperature:
-20 to +50deg.C for flow transmitter
-20 to +60deg.C for detector
Ambient humidity:
90%RH or less
Grounding: Class D (100 Ω or less)
Synchronization (option):
Simultaneous transmission eliminates cross
talk between multiple flow meters and mutual acoustic interference.
Number of connectable units: up to 31
Cable length: up to 15m
Master/Slave selectable
Arrester (option):
Arrester unit for outputs available (while arrester for power supply incorporated as standard)
2
Internal diameter Velocity: 2m/s or higher Velocity: Less than 2m/s
ø25 to ø50mm
±2.5% of rating
±0.05m/s
ø50 to ø600mm ±1.5% of rating
±0.03m/s
Metal pipe
Internal diameter Velocity: 2m/s or higher Velocity: Less than 2m/s
ø50 to ø600mm
±2% of rating
±0.04m/s
Note 1: Select FLSE31 or FLSE41 if the pipe is made of PP or PVDF.
The wall thickness of PP pipe is 15 mm or less, and that of
PVDF pipe is 9 mm or less.
Note 2: Select FLSE31 or FLSE41 for the pipes that do not transmit
ultrasound easily such as those made of cast iron, lining
pipes, and old steel pipes.
Note 3: When the 9th digit in the code symbol is “A”, the applicable
piping diameter is 50 to 150mm.
Accuracy rating:
Response time:System cycle: 0.2s
Dead time: 0.2s or less, Time constant: 0.1s
Power consumption:
15VA or less for AC power supply
5W or less for DC power supply
Permissible air volume rate:
Up to 0.2% at 1 m/s (inversely proportional
to velocity)
Short-term thermal stability:
140deg.C, 30min (in case FLSE 2)
Note: Use FLSE31/FLSE41 at the temperature of 80°C or lower.
Functional specifications
Analog output:4 to 20 mA DC (1 point)
Max. load resistance : 600 Ω
Digital output:+ total, - total, alarm, acting range, flow
switch or total switch arbitrarily available
Transistor open collector: 1 point (DO1)
Capacity: 30V DC, 0.1A
Normal off/on selectable
Total pulse: 1pulse/day to 100pps (Pulse
width: 5, 10, 50, 100 or 200ms)
Mechanical relay contact: 1point (DO2), with socket
(exchangeable)
Normal close/open selectable
Capacity: 220V AC /30V DC, 1A
(resistive load)
Mechanical expected life: More than 2 x 105
operations (under rated load)
Total pulse:1pulse/day to 1pps (Pulse width:
50, 100 or 200ms)
Communication interface (option):
RS-232C equivalent / RS-485
Number of connectable units: one (RS-232C)/
up to 31 (RS-485)
Baud rate:2400/4800/9600/19200 bps selectable
Parity: None/Odd/Even selectable
Stop bit: 1 or 2 bits selectable
Cable length:up to 15m (RS -232C)/up to
1km (RS-485)
Data: Velocity, flow rate, forward total, reverse total, status, etc.
Display device:2-color LED (Normal: green, Extraordinary:
red)
LCD with 2 lines of 16 characters and back
light
Display language:
English, Japanese, French, German or Spanish selectable
Velocity/Flow rate display:
Instantaneous velocity/flow rate display (The
flow of opposite direction is displayed by minus numerals.)
Numeral: 7 digits (decimal point be counted
as 1 digit)
Unit: Metric/Inch system selectable
Velocity
Flow rate
Metric system
m/s
L/s, L/min, L/h, kL/h,
ML/d, m3/s, m3/min,
m3/h, Mm3/d, BBL/s,
BBL/min, BBL/h,
MBBL/d
Inch system
ft/s
gal/s, gal/min, gal/h,
kgal/h, Mgal/d, ft3/s,
ft3/min, ft3/h, Mft3/d,
BBL/s, BBL/min, BBL/h, MBBL/d
Note: The “gal” means USgal.
Total display: Display of forward or reverse total
Numeral:7digits (decimal point be counted
as 1digit)
Unit: Metric/Inch system selectable
Total
Metric system
mL, L, m3, km3, Mm3,
mBBL, BBL, kBBL
Inch system
gal, kgal, ft3, kft3, Mft3,
mBBL, BBL, kBBL,
ACRE-in, ACRE-ft
Configuration:Fully configurable from the 4-key pad (ESC,
, , ENT) on the surface of flow transmitter’s housing case by menu-driven software
Zero adjustment:
Set Zero/Clear available
Damping:
0 to 100s (every 1s) configurable for analog
output and display
Low flow cut off :
0 to 5m/s configurable
Alarm:
Hardware fault/Process fault applicable to
digital output
Burnout:
Analog output : Hold/Over-scale/Under-scale/
Zero selectable
Total: Hold/Count selectable
Working timer: 0 to 100s (every 1s) configurable Bi-directional range:
Forward and reverse ranges configurable independently
Hysteresis: 0 to 10% of acting range configurable
Acting range applicable to digital output
Auto-2 ranges:Forward 2 ranges configurable independently
Hysteresis: 0 to 10% of acting range configurable
Acting range applicable to digital output
Flow switch: Lower and upper switching points configurable independently
Acting point applicable to digital output
Total switch: +total switching point configurable
Acting point applicable to digital output
Physical specifications
Enclosure protection:
Jetproof type (IP65) both for converter and
detector (FLSE 2: When waterproof BNC
connector is provided)
FLSE 1: Immersion-proof type (IP67) (When
the terminal block is filled with silicon rubber
after wiring)
Mounting:
Flow transmitter: Wall or 2B pipe mount
Detector: Clamped on pipe surface
Acoustic coupler:
Silicon rubber or silicon-free grease
Material:
Flow transmitter: Plastic ABS
Detector (type: FLSE 2):
Plastic PBT for sensor housing,
SUS304 for guide frame
Detector (type: FLSE 1):
Plastic PBT for sensor housing,
SUS304 for sensor cover, SUS304
and PBT for guide rail
Sensor cable:3D2V with outside diameter 5mm
Dimensions: Flow transmitter: H140 x W137 x D68mm
Detector: H50 x W228 x D34mm (FLSE1)
H50 x W348 xD34mm (FLSE2)
H40 x W500 x D80mm
(FLSE3: mounting V method)
H40 x W72 x D60mm
(FLSE4: mounting Z method)
Mass:
Flow transmitter: 0.8kg
Detector: 0.3kg (FLSE1) / 0.4kg (FLSE2)
1kg (FLSE3: mounting V method)
0.4kg (FLSE4: mounting Z method)
3
FLR, FLS, FLY
Conditions on straight pipe
( D : Inside diameter of pipe)
Classification
Upstream side
Downstream side
90 bend
10D or more
L
L
5D
10D
10D or more
Detector
Tee
L
L
10D
50D
0.5D
or more
10D or more
30D
L
10D
L
30D
L
5D
D
Diffuser
L
1.5D
L
5D
Reducer
L
10D
Various Valve
In case that flow control valve exists on
upstream side.
In case that flow control valve exists on
downstream side.
Stop valve
Check valve
L
Pump
(Note) The source : JEMIS-032
4
P
50D
MEASURING PRINCIPLE
CODE SYMBOLS
<Flow Transmitter>
Sensor
Upstream-side sensor
Flow transmitter
Analog output
θ
D
t1
t2
Velocity V
1 2 3 4 5 6 7 8
9 10 11 12
F LRE
1
2
Description
Type (4th digit)
Standard for exports
E
Power Supply (5th digit)
100 to 120Vac, 50/60Hz
200 to 240Vac, 50/60Hz
20 to 30Vdc
2
3
4
Contact output
Communication and
Synchronization (6th digit)
None
RS-232C
RS-485 and Synchronization
Synchronization
Downstream-side sensor
Y
A
B
C
The transit-time technique uses a pair of sensors with each
sensor sending and receiving ultrasonic signals obliquely
through the fluid.
Arrester (7th digit)
None
With arresters for outputs
Y
A
CONFIGURATION
Modification No. (8th digit)
Mark 2
2
(1) Single-path system (V method)
Case structure (9th digit)
Jetproof type (IP65)
1
Signal cable
Detector
Flow transmitter
Contact
signals
A
B
(2) Single-path system (Z method)
Signal cable
Flow transmitter
4 to 20mA DC
Contact
signals
(3) When using synchronization
Signal cable
Detector
4 to 20mA DC
Contact
signals
Detector
Flow
transmitter
(Slave)
<Detector>
1 2 3 4 5 6 7 8
9 10
F L S E
Y
3
Description
Type (4th digit)
Standard
1
2
3
4
Kind of detector (5th to 6th digit)
Small-dia. detector (ø25 to ø100 mm)
V
Small detector (ø50 to ø225 mm) *1 method
Small detector (ø50 to ø300 mm)
Small detector (ø300 to ø600 mm) Z method
2
2
1
1
Acoustic coupler (7th digit) (Note)
None
Silicon rubber
(Fluid temperature: -20 to +100 deg.C)
Silicon-free grease
(Fluid temperature: 0 to +60 deg.C)
Y
A
B
4 to 20mA DC
Contact
signals
Detector (12th digit)
FLSE12, FLSE22
FLSE31, FLSE41
(Note) This type has not so tough endurance against aeration as Fuji’s general use ultrasonic flowmeters TIME
DELTA-S/F (Model: FLV/FLH) and PORTAFLOW-X
(Model: FLC). For applications containing air bubbles, those general use flowmeters are recommendable to be used.
E
Flow
transmitter
(Master)
Synchronization
Signal cable
Parameter setting, tag plate (11th digit)
Without
With setting
With setting (Tag plate)
With Tag plate
Y
A
B
C
4 to 20mA DC
Detector
Mounting bracket (10th digit)
For 2B pipe mount
For wall mount
A
B
Modification No. (8th digit)
Mark 2
3
Y
B
Option (10th digit)
Without
Tag plate
*1) When the 9th digit in the code symbol is “A”,
the applicable piping diameter is 50 to 150mm.
<Dedicated Signal cable>
1 2 3 4 5 6 7 8
F L Y
1
Description
Type (4th digit)
Heat-resistant cable with one-side
waterproof BNC connector for FLSE12
and FLSE22
Heat-resistant cable for FLSE31 and FLSE41
3
4
0
0
0
0
0
0
1
1
2
3
Cable length (5th to 7th digit)
5m
10m
15m
20m
30m
5
0
5
0
0
1
Modification No. (8th digit)
Mark 1
(Note) Imcase FLSE 2, select silicon rubber (A) for acoustic coupler in ordinary cases. Silicon rubber is supplied in a tube (100g). If one or more detectors are
ordered, silicon rubber may be selected once every
5 orders or so.
Select silicon-free grease (B) for the use in an environment where generation of silicon is not desirable
such as semiconductor manufacturing facilities. The
silicon-free grease is soluble in water. Therefore,
do not use it in an environment subject to splash of
water or where condensation tends to occur on the
surface of the piping. The grease, which does not
become hardened, requires periodic maintenance
(cleaning and refilling of about once in 6 months at
room temperature).
5
FLR, FLS, FLY
OUTLINE DIAGRAM (Unit:mm)
<Flow transmitter (type: FLR)>
130
Mtg. plate
PIPE MOUNT (OPTION)
2.5
69
Mtg. holes 2-ø9
70
U bolt (M8)
(197)
170
140
Mtg.pipe
JIS 2B
M-Flow PW
137
Cable gland
External grounding terminal
For sensor cable (PG9)
For power supply and output cable (PG13.5)
CONNECTION DIAGRAM
AC power supply
1
L
RS-485 and Synchronization
UpUpI out DO1 DO2 stream stream
2
N
100 to 120V AC
or 200 to 240V AC
50/60Hz
SYNC SHILD TXDR2 TXDR1
Synchronization
RS-232C
GND HF2
NC
DC power supply
1
RS-485
GND HF1
GND RXD TXD
I out DO1 DO2 Down- Downstream stream
2
(Note)
DO1 : Transister open collector
DO2 : Mechanical relay contact
20 to 30V DC
<Detector (type: FLSE 2)>
SS TAG
(option)
(50)
H
L
Sensor
BNC connector
Frame
28
34
Lock clip
Spacing
(Adjustable every 3mm)
6
L
H
Spacing
Mass.
approx (kg)
FLSE12 25 to 100
228
31
21 to 120
0.3
FLSE22 50 to225
348
30
21 to 240
0.4
Type
Pipe size
(mm)
<Detector (type: FLSE31 V METHOD)>
Frame
Sensor
410±2
400
5
5
P
Name plate
47
Spacing : 0 to 270
Connection diagram
50±1
33
Chain
G
+
46±1
Mounting spring
(10)
Frame guide
VIEW FROM P
To flow transmitter
<Detector (type: FLSE41 Z METHOD)>
54±1
Name plate
Connection diagram
114
G
Sensor
+
Wire rope
46±1
ø19
Mounting spring
37±1
To flow transmitter
7
FLR, FLS, FLY
<Signal cable (type: FLY30)>
<Signal cable (type: FLY40)>
ø15
8
ø4.
3
BNC connector
(To Detector)
41
8.5
ø5
+1
+1
L 0 (m)
L 0 (m)
ø5
(To Flow transmitter)
ø3.
2
ø3.
2
5.5
5.5
*Note1
*Note1
Type
L
(m)
Mass. approx. (kg)
Type
L
(m)
Mass. approx. (kg)
FLY3005
FLY3010
FLY3015
FLY3020
FLY3030
5
10
15
20
30
0.6
1.2
1.8
2.4
3.6
FLY4005
FLY4010
FLY4015
FLY4020
FLY4030
5
10
15
20
30
0.6
1.2
1.8
2.4
3.6
*Note1: Total of two elements
SCOPE OF DELIVERY
Flow transmitter FLR: •Flow transmitter
•Instruction manual
Detector FLS:
•Sensor unit
•Mounting fixtures
•Silicon rubber or Silicon-free
grease (option)
Signal cable FLY :
•Cable (one pair)
*Note1: Total of two elements
The product conforms to the requirements of the
Electromagnetic compatibility Directive 89/336/EEC
as detailed within the technical construction file
number TN513321. The applicable standards used to
demonstrate compliance are :
EN 61326 : 1998
Electrical equipment for measurement, control and
laboratory use _____
EMC requirements
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/
Information in this catalog is subject to change without notice.