FUJITSU MB15F73UVPVB

FUJITSU SEMICONDUCTOR
DATA SHEET
DS04-21376-2E
ASSP
Dual Serial Input
PLL Frequency Synthesizer
MB15F73UV
■ DESCRIPTION
The Fujitsu MB15F73UV is a serial input Phase Locked Loop (PLL) frequency synthesizer with a 2250 MHz and
a 600 MHz prescalers. A 64/65 or a 128/129 for the 2250 MHz prescaler, and a 8/9 or a 16/17 for the 600 MHz
prescaler can be selected for the prescaler that enables pulse swallow operation.
The BiCMOS process is used, as a result a supply current is typically 3.2 mA at 2.7 V. The supply voltage range
is from 2.4 V to 3.6 V. A refined charge pump supplies well-balanced output current with 1.5 mA and 6 mA
selectable by serial data. The data format is the same as the previous one MB15F03SL, MB15F73SP/UL. Fast
locking is achieved for adopting the new circuit.
MB15F73UV is in the new small package (BCC18), which decreases a mount area of MB15F73UV about 50%
comparing with the former BCC20 (for dual PLL) .
MB15F73UV is ideally suited for wireless mobile communications, such as CDMA and PCS.
■ FEATURES
• High frequency operation
: RF synthesizer : 2250 MHz Max
: IF synthesizer : 600 MHz Max
• Low power supply voltage
: VCC = 2.4 V to 3.6 V
• Ultra low power supply current : ICC = 3.2 mA Typ
(VCC = 2.7 V, Ta = +25 °C, SWIF = SWRF = 0 in IF/RF locking state)
(Continued)
■ PACKAGES
18-pin plastic BCC
(LCC-18P-M05)
MB15F73UV
(Continued)
• Direct power saving function : Power supply current in power saving mode
Typ 0.1 µA (VCC = 2.7 V, Ta = +25 °C)
Max 10 µA (VCC = 2.7 V)
• Software selectable charge pump current : 1.5 mA/6.0 mA Typ
• Dual modulus prescaler : 2250 MHz prescaler (64/65 or128/129) /600 MHz prescaler (8/9 or 16/17)
• 23 bit shift register
• Serial input binary 14-bit programmable reference divider : R = 3 to 16,383
• Serial input programmable divider consisting of:
- Binary 7-bit swallow counter : 0 to 127
- Binary 11-bit programmable counter : 3 to 2,047
• Built-in high-speed tuning, low-noise phase comparator, current-switching type constant current circuit
• On-chip phase control for phase comparator
• On-chip phase comparator for fast lock and low noise
• Built-in digital locking detector circuit to detect PLL locking and unlocking
• Operating temperature : Ta = −40 °C to +85 °C
• Serial data format compatible with MB15F73UL
• Ultra small Package Bcc18 (2.4 mm x 2.7 mm x 0.45 mm)
■ PIN ASSIGNMENTS
(BCC-18)
TOP VIEW
Clock
OSCIN Data
GND
1
18 17 16 15
finIF
XfinIF
GNDIF
VCCIF
2
3
4
5
14
13
12
DOIF
6
7
8
9
finRF
11
XfinRF
GNDRF
VCCRF
10
DORF
PSIF PSRF
LD/fout
(LCC-18P-M05)
2
LE
MB15F73UV
■ PIN DESCRIPTION
Pin no.
BCC
Pin
name
I/O
1
GND

2
finIF
I
Prescaler input pin for the IF-PLL.
Connection to an external VCO should be AC coupling.
3
XfinIF
I
Prescaler complimentary input for the IF-PLL section.
This pin should be grounded via a capacitor.
4
GNDIF

Ground pin for the IF-PLL section.
5
VCCIF

Power supply voltage input pin for the IF-PLL section, the shift register and the oscillator input buffer.
6
DoIF
O
Charge pump output for the IF-PLL section.
7
PSIF
I
Power saving mode control pin for the IF-PLL section. This pin must be set at “L”
when the power supply is started up. (Open is prohibited.)
PSIF = “H” ; Normal mode/PSIF = “L” ; Power saving mode
8
LD/fout
O
Lock detect signal output (LD) /phase comparator monitoring output (fout) pin. The
output signal is selected by LDS bit in a serial data.
LDS bit = “H” ; outputs fout signal/LDS bit = “L” ; outputs LD signal
9
PSRF
I
Power saving mode control for the RF-PLL section. This pin must be set at “L” when
the power supply is started up. (Open is prohibited. )
PSRF = “H” ; Normal mode/PSRF = “L” ; Power saving mode
10
DoRF
O
Charge pump output for the RF-PLL section.
11
VCCRF

Power supply voltage input pin for the RF-PLL section.
12
GNDRF

Ground pin for the RF-PLL section
13
XfinRF
I
Prescaler complimentary input pin for the RF-PLL section.
This pin should be grounded via a capacitor.
14
finRF
I
Prescaler input pin for the RF-PLL.
Connection to an external VCO should be via AC coupling.
15
LE
I
Load enable signal input pin (with the schmitt trigger circuit)
When LE is set “H”, data in the shift register is transferred to the corresponding latch
according to the control bit in a serial data.
16
Data
I
Serial data input pin (with the schmitt trigger circuit)
Data is transferred to the corresponding latch (IF-ref. counter, IF-prog. counter,
RF-ref. counter, RF-prog. counter) according to the control bit in a serial data.
17
Clock
I
Clock input pin for the 23-bit shift register (with the schmitt trigger circuit)
One bit data is shifted into the shift register on a rising edge of the clock.
18
OSCIN
I
The programmable reference divider input pin. TCXO should be connected with an
AC coupling capacitor.
Descriptions
Ground pin for OSC input buffer and the shift register circuit.
3
MB15F73UV
■ BLOCK DIAGRAM
VCCIF GNDIF
5
4
Intermittent
mode control
(IF-PLL)
FCIF
SWIF
3 bit latch
LDS
PSIF 7
7 bit latch
11 bit latch
Phase
comp.
(IF-PLL)
Binary 7-bit
Binary 11-bit
swallow counter programmable
(IF-PLL)
counter (IF-PLL)
Charge
pump Current
(IF-PLL) Switch
6 DoIF
fpIF
finIF 2
XfinIF 3
Prescaler
(IF-PLL)
(8/9, 16/17)
Lock Det.
(IF-PLL)
2 bit latch
T1
T2
14 bit latch
1 bit latch
Binary 14-bit programmable ref.
counter(IF-PLL)
C/P setting
counter
LDIF
frIF
Fast
lock
Tuning
OSCIN 18
T1
T2
OR
2 bit latch
Selector
AND
frRF
Binary 14-bit programmable ref.
counter (RF-PLL))
C/P setting
counter
14 bit latch
1 bit latch
LD
frIF
frRF
fpIF
fpRF
8 LD/
fout
LDRF
LE 15
Data 16
Clock 17
Schmitt
circuit
Schmitt
circuit
FCRF
SWRF
Intermittent
mode control
(RF-PLL)
Schmitt
circuit
Binary 11-bit
Binary 7-bit
swallow counter programmable
counter (RF-PLL)
(RF-PLL)
3 bit latch
7 bit latch
Phase
comp.
(RF-PLL)
fpRF
11 bit latch
Latch selector
C C
N N
1 2
23-bit shift register
1
GND
4
Lock Det.
(RF-PLL)
fpRF
Fast lock
Tuning
PSRF 9
Prescaler
(RF-PLL)
(64/65, 128/129)
LDS
finRF 14
XfinRF 13
11
12
VCCRF GNDRF
Charge
Current
pump
Switch
(RF-PLL)
10 DoRF
MB15F73UV
■ ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Unit
Min
Max
VCC
−0.5
4.0
V
VI
−0.5
VCC + 0.5
V
LD/fout
VO
GND
VCC
V
DoIF, DoRF
VDO
GND
VCC
V
Tstg
−55
+125
°C
Power supply voltage
Input voltage
Output voltage
Rating
Storage temperature
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Value
Unit
Remarks
3.6
V
VCCRF = VCCIF

VCC
V

+85
°C
Min
Typ
Max
VCC
2.4
2.7
Input voltage
VI
GND
Operating temperature
Ta
−40
Power supply voltage
Notes : • VCCRF, VCCIF must supply equal voltage.
Even if either RF-PLL or IF-PLL is not used, power must be supplied to VCCRF, VCCIF to keep
them equal.
It is recommended that the non-use PLL is controlled by power saving function.
• Although this device contains an anti-static element to prevent electrostatic breakdown and the circuitry
has been improved in electrostatic protection, observe the following precautions when handling the device.
• When storing and transporting the device, put it in a conductive case.
• Before handling the device, confirm the (jigs and) tools to be used have been uncharged (grounded) as
well as yourself. Use a conductive sheet on working bench.
• Before fitting the device into or removing it from the socket, turn the power supply off.
• When handling (such as transporting) the device mounted board, protect the leads with a conductive
sheet.
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
5
MB15F73UV
■ ELECTRICAL CHARACTERISTICS
*
(VCC = 2.4 V to 3.6 V, Ta = −40 °C to +85 °C)
Parameter
Symbol
Input sensitivity
“L” level input voltage
“H” level input voltage
“L” level input voltage
“H” level input current
“L” level input current
Typ
Max
Unit
finIF = 480 MHz
VCCIF = 2.7 V
0.8
1.2
1.7
mA
ICCRF *1
finRF = 2000 MHz
VCCRF = 2.7 V
1.3
2.0
2.8
mA
IPSIF
PSIF = PSRF = “L”

0.1 *2
10
µA
IPSRF
PSIF = PSRF = “L”

0.1 *2
10
µA
finIF
IF PLL
50

600
MHz
fin *
finRF
RF PLL
200

2250
MHz
OSCIN
fOSC
3

40
MHz

finIF
PfinIF
IF PLL, 50 Ω system
−15

+2
dBm
finRF
PfinRF
RF PLL, 50 Ω system
−15

+2
dBm
0.5

1.5
VP−P
Input available voltage OSCIN
“H” level input voltage
Min
RF 3
finIF *3
Operating frequency
Value
ICCIF *1
Power supply current
Power saving current
Condition

VOSC
Data
LE
Clock
VIH
Schmitt triger input
0.7 VCC
+ 0.4


V
VIL
Schmitt triger input


0.3 VCC
− 0.4
V
PSIF
PSRF
VIH

0.7 VCC


V
VIL



0.3 VCC
V
Data
LE
Clock
PS
IIH *4

−1.0

+1.0
µA
IIL *4

−1.0

+1.0
µA
VCC − 0.4


V


0.4
V
VCC − 0.4


V
“H” level output voltage LD/
“L” level output voltage fout
VOH
VCC = 2.7 V, IOH = −1 mA
VOL
VCC = 2.7 V, IOL = 1 mA
“H” level output voltage DoIF
“L” level output voltage DoRF
VDOH
VCC = 2.7 V, IDOH = −0.5 mA
VDOL
VCC = 2.7 V, IDOL = 0.5 mA


0.4
V
IOFF
VCC = 2.7 V
VOFF = 0.5 V to Vcc − 0.5 V


2.5
nA
IOH *4
VCC = 2.7 V


−1.0
mA
IOL
VCC = 2.7 V
1.0


mA
High impedance cutoff DoIF
current
DoRF
“H” level output current LD/
“L” level output current fout
(Continued)
6
MB15F73UV
(Continued)
(VCC = 2.4 V to 3.6 V, Ta = −40 °C to +85 °C)
Parameter
Symbol
“H” level output
current
DoIF *8
DoRF
IDOH *4
“L” level output
current
DoIF *8
DoRF
IDOL
IDOL/IDOH IDOMT *5
Charge pump
current rate
DOVD 6
vs VDO
I
*
vs Ta
IDOTA *7
Value
Condition
Unit
Min
Typ
Max
CS bit = “1”
−8.2
−6.0
−4.1
mA
CS bit = “0”
−2.2
−1.5
−0.8
mA
CS bit = “1”
4.1
6.0
8.2
mA
CS bit = “0”
0.8
1.5
2.2
mA
VDO = Vcc / 2

3

%
0.5 V ≤ VDO ≤ Vcc − 0.5 V

10

%
−40 °C ≤ Ta ≤ +85 °C,
VDO = Vcc / 2

5

%
VCC = 2.7 V,
VDOH = Vcc / 2,
Ta = +25 °C
VCC = 2.7 V,
VDOL = Vcc / 2,
Ta = +25 °C
*1 : Conditions ; fosc = 12.8 MHz, Ta = +25 °C, SW = “0” in locking state.
*2 : VCCIF = VCCRF = 2.7 V, fosc = 12.8 MHz, Ta = +25 °C, in power saving mode.
PSIF = PSRF = GND
VIH = VCC, VIL = GND (at CLK, Data, LE)
*3 : AC coupling. 1000 pF capacitor is connected under the condition of Min operating frequency.
*4 : The symbol “–” (minus) means the direction of current flow.
*5 : VCC = 2.7 V, Ta = +25 °C (||I3| − |I4||) / [ (|I3| + |I4|) / 2] × 100 (%)
*6 : VCC = 2.7 V, Ta = +25 °C [ (||I2| − |I1||) / 2] / [ (|I1| + |I2|) / 2] × 100 (%) (Applied to both lDOL and lDOH)
*7 : VCC = 2.7 V, [||IDO (+85 °C) | − |IDO (–40 °C) || / 2] / [|IDO (+85 °C) | + |IDO (–40 °C) | / 2] × 100 (%) (Applied to both IDOL and IDOH)
*8 : When Charge pump current is measured, set LDS = “0” , T1 = “0” and T2 = “1”.
I3
I1
I2
IDOL
IDOH
I4
I2
I1
0.5
VCC/2
VCC − 0.5
VCC
Charge pump output voltage (V)
7
MB15F73UV
■ FUNCTIONAL DESCRIPTION
1. Pulse swallow function
fVCO = [ (P × N) + A] × fOSC ÷ R
fVCO : Output frequency of external voltage controlled oscillator (VCO)
P : Preset divide ratio of dual modulus prescaler (8 or 16 for IF-PLL, 64or 128 for RF-PLL)
N : Preset divide ratio of binary 11-bit programmable counter (3 to 2,047)
A : Preset divide ratio of binary 7-bit swallow counter (0 ≤ A ≤ 127, A < N)
fOSC : Reference oscillation frequency (OSCIN input frequency)
R : Preset divide ratio of binary 14-bit programmable reference counter (3 to 16,383)
2. Serial Data Input
The serial data is entered using three pins, Data pin, Clock pin, and LE pin. Programmable dividers of IF/RFPLL sections, programmable reference dividers of IF/RF-PLL sections are controlled individually.
The serial data of binary data is entered through Data pin.
On rising edge of Clock, one bit of the serial data is transferred into the shift register. On a rising edge of load
enable signal, the data stored in the shift register is transferred to one of latches depending upon the control bit
data setting.
The programmable The programmable
reference counter reference counter
for the IF-PLL
for the RF-PLL
The programmable
counter and the swallow
counter for the IF-PLL
The programmable
counter and the swallow
counter for the RF-PLL
CN1
0
1
0
1
CN2
0
0
1
1
(1) Shift Register Configuration
• Programmable Reference Counter
1
2
3
4
5
6
7
8
9
10 11 12 13
14
15
16
17
18
19 20 21 22 23
CN1 CN2 T1 T2 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 CS X
CS
R1 to R14
T1, T2
CN1, CN2
X
: Charge pump current select bit
: Divide ratio setting bits for the programmable reference counter (3 to 16,383)
: LD/fout output setting bit
: Control bit
: Dummy bits (Set “0” or “1”)
Note : Data input with MSB first.
8
X
X
X
MB15F73UV
• Programmable Counter
1
2
3
CN1 CN2 LDS
4
5
SWIF/
FCIF/
RF
RF
A1 to A7
N1 to N11
LDS
SWIF/RF
FCIF/RF
CN1, 2
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
23
A1 A2 A3 A4 A5 A6 A7 N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11
: Divide ratio setting bits for the swallow counter (0 to 127)
: Divide ratio setting bits for the programmable counter (3 to 2,047)
: LD/fout signal select bit
: Divide ratio setting bit for the prescaler (IF : SWIF, RF : SWRF)
: Phase control bit for the phase detector (IF : FCIF, RF : FCRF)
: Control bit
Note : Data input with MSB first.
(2) Data setting
• Binary 14-bit Programmable Reference Counter Data Setting
Divide ratio
R14 R13 R12 R11 R10 R9
R8
R7
R6
R5
R4
R3
R2
R1
3
0
0
0
0
0
0
0
0
0
0
0
0
1
1
4
•
•
•
16383
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
1
•
•
•
1
0
•
•
•
1
0
•
•
•
1
Note : Divide ratio less than 3 is prohibited.
• Binary 11-bit Programmable Counter Data Setting
Divide ratio N11 N10 N9
N8
N7
N6
N5
N4
N3
N2
N1
3
0
0
0
0
0
0
0
0
0
1
1
4
•
•
•
2047
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
1
•
•
•
1
0
•
•
•
1
0
•
•
•
1
Note : Divide ratio less than 3 is prohibited
• Binary 7-bit Swallow Counter Data Setting
Divide ratio
A7
A6
A5
A4
A3
A2
A1
0
0
0
0
0
0
0
0
1
•
•
•
127
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
0
•
•
•
1
1
•
•
•
1
9
MB15F73UV
• Prescaler Data Setting
SW = “1”
SW = “0”
Prescaler divide ratio IF-PLL
8/9
16/17
Prescaler divide ratio RF-PLL
64/65
128/129
Divide ratio
• Charge Pump Current Setting
Current value
CS
±6.0 mA
1
±1.5 mA
0
• LD/fout output Selectable Bit Setting
LD/fout pin state
LDS
T1
T2
0
0
0
0
1
0
0
1
1
frIF
1
0
0
frRF
1
1
0
fpIF
1
0
1
fpRF
1
1
1
LD output
fout
output
• Phase Comparator Phase Switching Data Setting
FCIF, FCRF = “1”
FCIF, FCRF = “0”
DoIF, DoRF
DoIF, DoRF
fr > fp
H
L
fr < fp
L
H
fr = fp
Z
Z
Phase comparator input
Z : High-impedance
Depending upon the VCO and LPF polarity, FC bit should be set.
High
(1)
(1) VCO polarity FC = “1”
(2) VCO polarity FC = “0”
VCO Output
Frequency
(2)
LPF Output voltage
Note : Give attention to the polarity for using active type LPF.
10
Max
MB15F73UV
3. Power Saving Mode (Intermittent Mode Control Circuit)
Status
PS pin
Normal mode
H
Power saving mode
L
The intermittent mode control circuit reduces the PLL power consumption.
By setting the PS pin low, the device enters into the power saving mode, reducing the current consumption. See
the Electrical Characteristics chart for the specific value.
The phase detector output, Do, becomes high impedance.
For the dual PLL, the lock detector, LD, is as shown in the LD Output Logic table.
Setting the PS pin high, releases the power saving mode, and the device works normally.
The intermittent mode control circuit also ensures a smooth startup when the device returns to normal operation.
When the PLL is returned to normal operation, the phase comparator output signal is unpredictable. This is
because of the unknown relationship between the comparison frequency (fp) and the reference frequency (fr)
which can cause a major change in the comparaor output, resulting in a VCO frequency jump and an increase
in lockup time.
To prevent a major VCO frequency jump, the intermittent mode control circuit limits the magnitude of the error
signal from the phase detector when it returns to normal operation.
Notes : • When power (VCC) is first applied, the device must be in standby mode, PS = Low, for at least 1 µs.
• Serial data input are done after the power supply becomes stable, and then the power saving mode is
released after completed the data input.
OFF
V CC
ON
tV ≥ 1 µs
Clock
Data
LE
tPS ≥ 100 ns
PS
(1)
(2)
(3)
(1) PS = L (power saving mode) at Power-ON
(2) Set serial data at least 1 µs after the power supply becomes stable (VCC ≥ 2.2 V) .
(3) Release power saving mode (PSIF, PSRF : “L” → “H”) at least 100 ns later after setting serial data.
11
MB15F73UV
4. Serial Data Data Input Timing
Divide ratio is performed through a serial interface using the Data pin, Clock pin, and LE pin.
Setting data is read into the shift register at the rise of the Clock signal, and transferred to a latch at the rise of
the LE signal. The following diagram shows the data input timing.
1st data
2nd data
Invalid data
Control bit
Data
MSB
LSB
Clock
t1
t2
t3
t6
t7
LE
t4
Parameter
Min
Typ
Max
Unit
Parameter
Min
Typ
Max
Unit
t1
20


ns
t5
100


ns
t2
20


ns
t6
20


ns
t3
30


ns
t7
100


ns
t4
30


ns
Note : LE should be “L” when the data is transferred into the shift register.
12
t5
MB15F73UV
■ PHASE COMPARATOR OUTPUT WAVEFORM
fr IF/RF
fp IF/RF
t WU
t WL
LD
(FC bit = 1)
D o IF/RF
H
Z
L
(FC bit = 0)
H
D o IF/RF
Z
L
• LD Output Logic
IF-PLL section
RF-PLL section
LD output
Locking state/Power saving state
Locking state/Power saving state
H
Locking state/Power saving state
Unlocking state
L
Unlocking state
Locking state/Power saving state
L
Unlocking state
Unlocking state
L
Notes : •
•
•
•
•
Phase error detection range = −2π to +2π
Pulses on DoIF/RF signals during locking state are output to prevent dead zone.
LD output becomes low when phase error is tWU or more.
LD output becomes high when phase error is tWL or less and continues to be so for three cycles or more.
tWU and tWL depend on OSCIN input frequency as follows.
tWU ≥ 2/fosc : e.g. tWU ≥ 156.3 ns when fosc = 12.8 MHz
tWU ≤ 4/fosc : e.g. tWL ≤ 312.5 ns when fosc = 12.8 MHz
13
MB15F73UV
■ TEST CIRCUIT (for Measuring Input Sensitivity fin/OSCIN)
S.G.
1000 pF
50 Ω
S.G.
1000 pF
Controller
(divide ratio setting)
50 Ω
OSCIN
Clock
Data
LE
GND
S.G.
1
18
17
16
15
1000 pF
finIF
50 Ω
XfinIF
2
14
3
13
VCCRF
finRF
1000 pF
1000 pF
MB15F73UV
4
12
5
11
XfinRF
0.1 µF
GNDRF
GNDIF
VCCRF
VCCIF
DoIF
6
7
8
9
LD/
fout
PSIF
10
DoRF
PSRF
0.1 µF
Oscilloscope
14
MB15F73UV
■ TYPICAL CHARACTERISTICS
1. fin input sensitivity
RF-PLL input sensitivity vs. Input frequency characteristic
10
0
Catalog guaranteed range
PfinRF (dBm)
−10
−20
−30
VCC = 2.4 V
VCC = 2.7 V
VCC = 3.0 V
VCC = 3.6 V
spec
−40
−50
0
500
1000
1500
2000
2500
3000
finRF (MHz)
IF-PLL input sensitivity vs. Input frequency characteristic
10
0
PfinIF (dBm)
Catalog guaranteed range
−10
−20
VCC = 2.4 V
VCC = 2.7 V
VCC = 3.0 V
VCC = 3.6 V
SPEC
−30
−40
−50
0
200
400
600
800
1000
finIF (MHz)
15
MB15F73UV
2. OSCIN input sensitivity
Input sensitivity vs. Input frequency
Input sensitivity VOSC (dBm)
10
Catalog guaranteed range
0
−10
−20
VCC = 2.4 V
VCC = 2.7 V
VCC = 3.0 V
VCC = 3.6 V
spec
−30
−40
−50
0
20
40
60
80
100
Input frequency fOSC (MHz)
16
120
140
160
MB15F73UV
3. RF/IF-PLL Do output current
• CP = 1.5 mA
Charge Pomp Output Voltage vs. Charge Pomp Output Current
Charge pomp output current IDO (mA)
2.50
2.00
VCC = 2.7 V, Ta = +25˚C
1.50
1.00
0.50
0.00
−0.50
−1.00
−1.50
−2.00
−2.50
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Charge pomp output voltage VDO (V)
• CP = 6.0 mA
Charge Pomp Output Voltage vs. Charge Pomp Output Current
Charge pomp output current IDO (mA)
8.00
VCC = 2.7 V, Ta = +25˚C
6.00
4.00
2.00
0.00
−2.00
−4.00
−6.00
−8.00
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Charge pomp output voltage VDO (V)
17
MB15F73UV
4. fin input impedance
finIF input impedance
4 : 21.109 Ω
−146.41 Ω
1.8117 pF
600.000 000 MHz
1 : 927.81 Ω
−1.1572 kΩ
50 MHz
2:
99.75 Ω
−453.91 Ω
200 MHz
3 : 34.141 Ω
−228.06 Ω
400 MHz
1
2
4
START 50.000 000 MHz
3
STOP 1 000.000 000 MHz
finRF input impedance
4 : 7.4382 Ω
2.5134 Ω
181.83 pH
2 200.000 000 MHz
1 : 17.516 Ω
−120.82 Ω
700 MHz
2 : 11.105 Ω
−57.764 Ω
1.2 GHz
3 : 8.8408 Ω
−25.122 Ω
1.7 GHz
4
1
3
2
START 200.000 000 MHz
18
STOP 2 250.000 000 MHz
MB15F73UV
5. OSCIN input impedance
OSCIN input impedance
4 : 272.06 Ω
−1.0519 kΩ
3.7826 pF
40.000 000 MHz
1 : 2.2315 kΩ
−2.3139 kΩ
10 MHz
2 : 858.38 Ω
−1.8481 kΩ
20 MHz
4
1
2
3
START 3.000 000 MHz
3 : 437.13 Ω
−1.3529 kΩ
30 MHz
STOP 40.000 000 MHz
19
MB15F73UV
■ REFERENCE INFORMATION
(for Lock-up Time, Phase Noise and Reference Leakage)
fVCO = 2113.6 MHz
KV = 50 MHz/V
fr = 50 kHz
fOSC = 19.2 MHz
LPF
Test Circuit
S.G.
OSCIN
Do
VCC = 2.7 V
VVCO = 2.8 V
Ta = + 25 °C
CP : 1.5 mA mode
LPF
fin
33 k Ω
Spectrum
Analyzer
VCO
2700 pF
6.2 k Ω
To VCO
680 pF
0.027 µF
• PLL Reference Leakage
ATTEN 10 dB
RL 0 dBm
VAVG 0
10 dB/
∆MKR −81.50 dB
50.0 kHz
∆MKR
50.0 kHz
−81.50 dB
CENTER 2.1136000 GHz
∗ RBW 1.0 kHz
VBW 1.0 kHz
SPAN 200.0 kHz
SWP 500 ms
• PLL Phase Noise
ATTEN 10 dB
RL 0 dBm
VAVG 16
10 dB/
∆MKR −66.51 dB/Hz
1.00 kHz
∆MKR
1.0 kHz
−66.51 dB/Hz
CENTER 2.11360000 GHz
∗ RBW 30 Hz
VBW 30 Hz
SPAN 10.00 kHz
SWP 1.92 s
(Continued)
20
MB15F73UV
(Continued)
PLL Lock Up time
2113.6 MHz→2173.6 MHz ± 1 kHz
L ch→H ch 1.80 ms
DMkr x: 1.79999289 ms
y: 59.96897 MHz
100.0050 MHz
2.00 kHz/div
99.99500 MHz
0.00 s
4.0000000 ms
PLL Lock Up time
2173.6 MHz→2113.6 MHz ± 1 kHz
H ch→L ch 1.54 ms
DMkr x: 1.54000169 ms
y: -59.9935 MHz
100.0050 MHz
2.00 kHz/div
99.99500 MHz
0.00 s
4.0000000 ms
21
MB15F73UV
■ APPLICATION EXAMPLE
1000 pF
Controller
(divide ratio setting)
TCXO
OSCIN
Clock
Data
LE
OUTPUT
OUTPUT
GND
1
18
17
16
15
1000 pF
2
14
3
13
1000 pF
finRF
finIF
XfinIF
1000 pF
1000 pF
VCO
MB15F73UV
4
12
5
11
VCO
XfinRF
GNDRF
GNDIF
VCCRF
LPF
VCCIF
VCCRF
6
VCCIF
7
8
9
LPF
0.1 µF
10
DoRF
DoIF
PSRF
PSIF
0.1 µF
LD/
fout
Lock Detect
Note : Clock, Data, LE : The schmitt trigger circuit is provided (insert a pull-down or pull-up register
to prevent oscillation when open-circuit in the input) .
22
MB15F73UV
■ USAGE PRECAUTIONS
(1) VCCRF and VCCIF must be equal voltage.
Even if either RF-PLL or IF-PLL is not used, power must be supplied to VCCRF, VpRF, VCCIF and VpIF to keep
them equal. It is recommended that the non-use PLL is controlled by power saving function.
(2) To protect against damage by electrostatic discharge, note the following handling precautions :
-Store and transport devices in conductive containers.
-Use properly grounded workstations, tools, and equipment.
-Turn off power before inserting or removing this device into or from a socket.
-Protect leads with conductive sheet, when transporting a board mounted device
■ ORDERING INFORMATION
Part number
MB15F73UVPVB
Package
Remarks
18-pin plastic BCC
(LCC-18P-M05)
23
MB15F73UV
■ PACKAGE DIMENSIONS
18-pin plastic BCC
(LCC-18P-M05)
15
2.70±0.10
(.106±.004)
INDEX AREA
0.45±0.05
(.018±.002)
(Mount height)
10
10
2.01(.079)
TYP
2.40±0.10
(.094±.004)
0.45(.018)
TYP.
1
0.075±0.025
(.003±.001)
(Stand off)
6
2.31(.090)
TYP
0.45(.018)
TYP.
0.90(.035)
REF 1.90(.075)
REF
"A"
"B"
"C"
6
15
1.35(.053)
REF
1
2.28(.090)
REF
Details of "A" part
0.05(.002)
0.14(.006)
MIN.
Details of "B" part
0.25±0.06
(.010±.002)
0.25±0.06
(.010±.002)
C
C0.10(.004)
Details of "C" part
0.36±0.06
(.014±.002)
0.28±0.06
(.011±.002)
0.36±0.06
(.014±.002)
0.28±0.06
(.011±.002)
2003 FUJITSU LIMITED C18058S-c-1-1
Dimensions in mm (inches)
Note : The values in parentheses are reference values.
24
MB15F73UV
FUJITSU LIMITED
All Rights Reserved.
The contents of this document are subject to change without notice.
Customers are advised to consult with FUJITSU sales
representatives before ordering.
The information, such as descriptions of function and application
circuit examples, in this document are presented solely for the
purpose of reference to show examples of operations and uses of
Fujitsu semiconductor device; Fujitsu does not warrant proper
operation of the device with respect to use based on such
information. When you develop equipment incorporating the
device based on such information, you must assume any
responsibility arising out of such use of the information. Fujitsu
assumes no liability for any damages whatsoever arising out of
the use of the information.
Any information in this document, including descriptions of
function and schematic diagrams, shall not be construed as license
of the use or exercise of any intellectual property right, such as
patent right or copyright, or any other right of Fujitsu or any third
party or does Fujitsu warrant non-infringement of any third-party’s
intellectual property right or other right by using such information.
Fujitsu assumes no liability for any infringement of the intellectual
property rights or other rights of third parties which would result
from the use of information contained herein.
The products described in this document are designed, developed
and manufactured as contemplated for general use, including
without limitation, ordinary industrial use, general office use,
personal use, and household use, but are not designed, developed
and manufactured as contemplated (1) for use accompanying fatal
risks or dangers that, unless extremely high safety is secured, could
have a serious effect to the public, and could lead directly to death,
personal injury, severe physical damage or other loss (i.e., nuclear
reaction control in nuclear facility, aircraft flight control, air traffic
control, mass transport control, medical life support system, missile
launch control in weapon system), or (2) for use requiring
extremely high reliability (i.e., submersible repeater and artificial
satellite).
Please note that Fujitsu will not be liable against you and/or any
third party for any claims or damages arising in connection with
above-mentioned uses of the products.
Any semiconductor devices have an inherent chance of failure. You
must protect against injury, damage or loss from such failures by
incorporating safety design measures into your facility and
equipment such as redundancy, fire protection, and prevention of
over-current levels and other abnormal operating conditions.
If any products described in this document represent goods or
technologies subject to certain restrictions on export under the
Foreign Exchange and Foreign Trade Law of Japan, the prior
authorization by Japanese government will be required for export
of those products from Japan.
F0312
 FUJITSU LIMITED Printed in Japan