MAKE-PS 205S12WFR

www.make-ps.com
E-mail:[email protected]
200WFR series
Single Output
DC/DC Converter
FEATURES
•
•
•
•
•
•
•
High Efficiency up to 81%
1000VDC Isolation
MTBF > 1,000,000 Hours
2:1 Wide Input Range
Low Cost
Remote On/Off Control
Low Ripple and Noise
DESCRIPTIONS
INPUT CHARACTERISTICS
The 200WFR series are low-profile 2 watts dc-dc converters
that operate over input voltage ranges of 4.5 to 9VDC and 9 to
18VDC, 18 to 36VDC and 36 to 75 VDC and provide precisely
regulated output voltages of 3.3V, 5V and 12VDC.
Min Typ Max Units/Comments
Start Voltage
5 VDC Input Models
VDC
2.8 3.2 4.5
12 VDC Input Models
VDC
9
4.5 6
24 VDC Input Models
VDC
8
12 18
48 VDC Input Models
VDC
16 24 36
Under Voltage Shut Down
5 VDC Input Models
VDC
4
3
12 VDC Input Models
VDC
5.5 8.5
24 VDC Input Models
VDC
11 17
48 VDC Input Models
VDC
22 36
Reverse Polarity Input Current
A
1
Short Circuit Input Power
mW
1500
Input Filter
Capacitor type
The -40oC to +65oC operating temperature range makes it
ideal for data communication equipment, mobile battery
driven equipment, distributed power systems, telecommunication
equipment, mixed analog/digital subsystems, process/
machine control equipment, computer peripheral systems
and industrial robot systems.
OUTPUT CHARACTERISTICS
Min Typ Max Unit/Comments
±1 ±2 % Output voltage at
nominal line & FL
±0.3 ±0.5 Change /
Line Regulation
Percentage change
in Input
voltage
±0.5 ±0.75 % Output voltage
Load Regulation
measured from
full load to
10% load
120
Over Power Protection
%
±0.01 ±0.02 % per degree C
Temperature Coefficient
30 50 mV p-p measured
Ripple/Noise
at 20 MHz bandwidth
with external 1 μf
capacitor
75 mV p-p, Over Line,
Ripple/Noise
Load & Temp., 20
MHz B.W., using 1μf
bypass capacitor
Output Voltage and Current
Refer to model
selection chart
±3 ±5 % deviation of Vout
Load Transient Response
voltage for a 25%
load change for
500μS
Short Circuit Protection
Indefinite, Automatic
Recovery
Output Voltage Set Point
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Remote On/Off
On
Off
Min Typ Max Unit/Comments
kHz
100 300 650
VDC, 1 minute
1000
Mohm, 500VDC
1000
65 120 pF, 100kHz, 1Volt
Million Hours,
1
+25oC, Ground
Benign
2.7
0
15
0.6
VDC; Referenced to
input return
>> B-41
www.make-ps.com
E-mail:[email protected]
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Min
-40
-40
-55
PHYSICAL CHARACTERISTICS
Typ Max
+65
+90
+105
95
Cooling
Unit/Comments
o
C; Ambient
o
C; Case
o
C; Case
% Humidity; noncondensing
Free-Air Convection
Unit/Comments
0.86 X 0.36 X 0.44 inches
(21.8 X 9.2 X 11.2 mm)
Non-Conductive Black Plastic
UL94V-0
4.8 Grams
Case Size
Case Material
Flammability
Weight
OUTLINE DRAWING
0.86 (21.8)
0.02
(0.5)
SIDE VIEW
0.44
(11.2)
0.16 (4.0)
0.200 (5.08)
0.08 (2.0)
0.100 (2.54)
BOTTOM VIEW
1
2
3
5
6
7
8
0.01
(0.25)
0.36 (9.2)
0.12
(3.0)
0.02 (0.5)
PIN OUT CHART
Pins
1
2
3
5
6
7
8
Function
- Vin
+ Vin
Remote On/Off
NC
+ Vout
- Vout
NC
NC = No Connection
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
Tolerances: X.XX = ±0.02 (±0.5)
X.XXX = ±0.010 (±0.25)
Pin: ±0.002 (±0.05)
All specifications are typical at nominal input, nominal load and 25° C unless otherwise specified.
External, low ESR, 10 microfarad (minimum) capacitor across input is recommended for operation.
>> B-42
www.make-ps.com
E-mail:[email protected]
HOW TO ORDER
HOW TO ORDER
2 XX S XX WFR - Y
ROHS Compliant
Series
Nominal
Input Range
Wattage
Output Voltage
Output
Configuration
(S=Single)
MODEL SELECTION CHART
Model
203S5WFR
205S5WFR
212S5WFR
203S12WFR
205S12WFR
212S12WFR
203S24WFR
205S24WFR
212S24WFR
203S48WFR
205S48WFR
212S48WFR
Nominal
Input
Voltage
(VDC)
5
5
5
12
12
12
24
24
24
48
48
48
Input
Voltage
Range
(VDC)
4.5 - 9
4.5 - 9
4.5 - 9
9 - 18
9 - 18
9 - 18
18 - 36
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
Min.
Output
Current
(mA)
125
100
42
125
100
42
125
100
42
125
100
42
Max.
Output
Current
(mA)
500
400
167
500
400
167
500
400
167
500
400
167
Output
Voltage
(VDC)
3.3
5.0
12.0
3.3
5.0
12.0
3.3
5.0
12.0
3.3
5.0
12.0
Efficiency
@ Full Load
(%)
Input
Fuse
(mA)
70
73
75
73
77
80
72
77
81
71
73
79
1500
1500
1500
700
700
700
350
350
350
135
135
135
DERATING CURVES
MODEL 200WFR
Pout %
100
90
80
70
60
50
40
30
20
10
0
-40
100LFM
400LFM
Natural
Convection
200LFM
50
60
70
80
90
100
110
TEMPERATURE ° C
>> B-43