MEANWELL SP-750-12

SP-750
750W Single Output Power Supply
series
Features :
Universal AC input / Full range
AC input active surge current limiting
Built-in active PFC function,PF>0.96
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC ball bearing fan
High power density 5.48/inch3
Built-in constant current limiting circuit
With power good and fail signal output
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
OUTPUT
SP-750-5
SP-750-12
SP-750-15
SP-750-24
SP-750-27
SP-750-48
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
120A
62.5A
50A
31.3A
27.8A
15.7A
CURRENT RANGE
0 ~ 120A
0 ~ 62.5A
0 ~ 50A
0 ~ 31.3A
0 ~ 27.8A
0 ~ 15.7A
RATED POWER
600W
750W
750W
751.2W
750.6W
753.6W
RIPPLE & NOISE (max.) Note.2 120mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
10 ~ 13.5V
13.5 ~ 16.5V
22 ~ 26.4V
VOLTAGE TOLERANCE Note.3
INPUT
4.75 ~ 5.5V
2.0%
43 ~ 56V
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1500ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.96/230VAC
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
80%
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
<2.0mA / 240VAC
85
OVER TEMPERATURE
87%
89%
5
89%
90%
31 ~ 36.5V
57.6 ~ 67.2V
4.2A/230VAC
45A/230VAC
(TSW1 ) detect on heatsink of power transistor
85
5
(TSW2 ) detect on heatsink of power diode
50ms/1ms
Note.5 RC+/RC- short power on, open power off
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
WITHSTAND VOLTAGE
PF>0.99/115VAC at full load
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
POWER GOOD/FAIL
TEMP. COEFFICIENT
VIBRATION
16ms/115VAC at full load
127 ~ 370VDC
105 ~ 125% rated output power
Protection type : Constant current limiting, unit will Hiccup after 3 sec.
5.75 ~ 6.75V
13.8 ~ 16.2V
18 ~ 21V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
REMOTE CONTROL
1500ms, 50ms/115VAC at full load
85%
8.8A/115VAC
27A/115VAC
OVERLOAD
FUNCTION
24 ~ 30V
1.0%
-20 ~ +60 (Refer to output load derating curve)
20~90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
124K hrs min. MIL-HDBK-217F (25
278*127*63.5mm (L*W*H)
2.9Kg; 6pcs / 18.4Kg / 0.98CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. The power supply unit will have no output if the shorting connector is not assembled between RC+ & RC-.
File Name:SP-750-SPEC 2010-10-18
SP-750
750W Single Output Power Supply
Mechanical Specification
Case No.919A
220
series
Unit:mm
113
16
5
30
20
4-M3
7
6-M3 L=6
149
4-M3
Air flow
direction
O/P
5
CONTROL
33
11
72
24.5
91
240
251
278
2
1
2
3
4
40.5
5
6
7
8
+V ADJ.
1
2
3
7
7 10
39
113
127
1
I/P
19 max.
4-M3
28 max.
220
34.5
20
63.5
20 max.
2-M6
15
BOTTOM VIEW
TOP VIEW
AC Input Terminal
Pin No. Assignment
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
DC Output Terminal
Pin No. Assignment
Pin No.
1
2
Assignment
DC OUTPUT +V
DC OUTPUT -V
Control Pin No. Assignment : MOLEX 5559-NP uses 5558male crimp terminal
Pin No.
1
2
3
4
Assignment
NC
-S
G
RC-
Pin No. Assignment Mating connector
Terminal
NC
5
MOLEX 5556
6
PF(Power fail signal)
MOLEX 5557-NR Female crimp
Terminal
+S
7
receptacle
RC+
8
Block Diagram
PFC fosc : 100KHz
PWM fosc : 140KHz
+S
I/P
EMI
FILTER
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
PWM
POWER
SWITCHING
PFC
POWER
SWITCHING
DETECTION
CIRCUIT
PFC
CONTROL
RECTIFIERS
&
FILTER
O.T.P.
CURRENT
LIMIT
+V
-V
-S
O.L.P.
DETECTION
CIRCUIT
PWM
CONTROL
PF
O.V.P.
O.T.P.
REMOTE
CONTROL
AUX
POWER
FAN
RC
FAN LOCK
PROTECTION
File Name:SP-750-SPEC 2010-10-18
SP-750
750W Single Output Power Supply
Derating Curve
series
Static Characteristics
100
100
90
80
85
70
LOAD (%)
LOAD (%)
60
40
20
-20
60
50
40
0
10
20
30
40
50
60
70 (HORIZONTAL)
90
95
100
115
260
INPUT VOLTAGE (VAC) 60Hz
AMBIENT TEMPERATURE ( )
Control Terminal Instruction Manual
Remote Sensing
Power Fail Signal
PF Signal is the voltage difference between
"G" and "PF" pin output
G
PF
RC+ +S PF NC
RC+ +S PF NC
RC- G
RC- G
-S NC
-V
-S NC
+V
LOAD
+
+V
-V
-S
LOAD
+
+S
Remote Control
Power ON: RC+/RC- Short
Power OFF: RC+/RC- open
RC- RC+
RC+ +S PF NC
RC- G
-S NC
+V
-V
LOAD
+
File Name:SP-750-SPEC 2010-10-18