VICOR VE-23Y-EW

Data Sheet
VI-200, VE-200
DC-DC Converters
50 to 200 Watts
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
RoHS compliant (VE-200)
Up to 50 W/in3
cULus, cTÜVus
Up to 90% efficiency
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7mm)
Remote sense and current limit
OVP, thermal shutdown
Logic disable
Wide range output adjust
Compatible power booster modules
ZCS power architecture
Low noise FM control
CE Marked
Isolated output
Product Highlights
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of
“zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2 MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable of
supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
Part Numbering
VI
Family
VI = Non-RoHS
VE = RoHS
Series
2
6
1
Input
2 = 200
0 = 12 V
B = Booster
Note: For additional
packaging options,
please see page 4.
—
—
C
W
Output
Grade
M = 10 V
Power
N = 48 V
Z = 2V
K = 40 V
E = –10 to 85°C
≥ 5V
< 5V
V = 24 V
4 = 72 V
Y = 3.3 V
1 = 24 V
T = 110 V
0 = 5V
1 = 12 V
4 = 48 V
C = –25 to 85°C
U = 200 W
U = 40 A
P = 13.8 V
H = 52 V
I = – 40 to 85°C
V = 150 W
W = 24 V
5 = 150 V
X = 5.2 V
2 = 15 V
V = 30 A
F = 72 V
M = –55 to 85°C
W = 100 W
W = 20 A
2 = 36 V
6 = 300 V
W = 5.5 V
N = 18.5 V
D = 85 V
X = 75 W
X = 15 A
3 = 48 V
7 = 150/300 V
V = 5.8 V
3 = 24 V
B = 95 V
Y = 50 W
Y = 10 A
T = 6.5 V
L = 28 V
R = 7.5 V
J = 36 V
Maximum Power Available for VI-2xx-xx [a]
Input
Output
Voltage
Nom. (Range)
Low Line
75%
Max Power
Transient[b]
12 (10-20)
n/a
22
0
24 (10-36)
n/a
n/a
24 (21-32)
18
24 (18-36)
36 (21-56)
Vin
2
Designators
Z
Vout Designators
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36
3.3
5
Y
0
X
W
V
T
R
M
1
P
2
N
3
L
J
40 48 52 72 85 95
K
4
H
F
D
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
V
--
X
Y
Y
Y
Y
Y
X
X
X
X
X
X
X
X
X
X
X
--
--
--
--
36
1
U
U
U
U
U
U
V
V
U
U
U
U
U
U
U
U
U
U
U
U
U
U
n/a
n/a
W
V
V
V
V
V
V
W
W
V
V
V
V
V
V
V
V
V
V
V
V
V
V
18
60
2
W
V
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
--
--
--
B
48 (42-60)
36
72
3
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
48 (36-76)
n/a
n/a
N
V
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
72 (55-100)
45
110
4
U
U
U
U
U
U
V
V
U
U
U
U
U
U
U
U
U
U
U
U
U
110 (66-160)
n/a
n/a
T
V
V
V
V
V
V
W
W
V
V
V
V
V
V
V
V
V
V
V
V
--
--
150 (100-200)
85
215
5
U
U
V
V
V
V
V
V
U
U
U
U
U
U
U
U
U
U
U
U
U
U
150 (100-375)
90
n/a
7
W
W
Y
Y
Y
Y
W
W
W
W
W
W
W
W
W
W
W
W
W
--
--
--
300 (200-400)
170
425
6
U
U
U
U
U
U
V
V
U
U
U
U
U
U
U
U
U
U
U
U
U
U
[a]
For additional output power, “booster” modules are available. (VI-Bxx-xx)
[b]
Transient voltage for 1 second.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.9
Page 1 of 5
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
VI-200 E-Grade
Parameter
Min
Typ
Inrush charge
120 x 10
Input reflected
ripple current – pp
VI-200 C-, I-, M-Grade
Max
Min
Typ
-6
120 x 10
10%
200 x 10
10%
( )
20+20 Log ( Vin )
( )
30+20 Log Vin
25+20 Log Vin
Input ripple rejection
Max
-6
Vout
Vout
Vout
No load power dissipation
1.35
2
1.35
Units
-6
Coulombs
Test Conditions
Nominal line
IIN
Nominal line, full load
dB
120 Hz, nominal line
dB
2400 Hz, nominal line
2
Watts
Typ
Max
Units
OUTPUT CHARACTERISTICS
VI-200 E-Grade
Parameter
Min
VI-200 C-, I-, M-Grade
Typ
Max
1%
2%
0.5%
1%
VNOM
Load/line regulation
0.5%
0.05%
0.2%
VNOM
LL to HL, 10% to Full Load
Load/line regulation
1%
0.2%
0.5%
VNOM
LL to HL, No Load to 10%
0.02
% / °C
Setpoint accuracy
Min
Output temperature drift
0.02
0.01
Long term drift
0.02
0.02
Output ripple – pp:
2 V, 3.3 V
100
mV
20 MHz bandwidth
5V
5%
2%
3%
VNOM
20 MHz bandwidth
10 – 95 V
3%
0.75%
1.5%
VNOM
20 MHz bandwidth
110%
VNOM
Total remote
sense compensation
0.5
110%
Current limit
Short circuit
current [c]
50%
0.5
125%[b]
OVP set point
[c]
%/1K hours
60
50%
[b]
Over rated temp.
150
Trim range[a]
[a]
Test Conditions
115%
125%[b]
Volts
0.25 V max. neg. leg
135%
VNOM
Recycle power
Automatic restart
105%
135%
105%
125%
INOM
20%
140%
20%
130%
INOM
10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
3.3 V output trim range 2.20 to 3.63 V, 95 V output –50 + 0% trim range.
131% nominal for booster modules.
Output voltages of 3.3 V or 5 V incorporate foldback current limiting; For output voltages from 5.2 V to 7.5 V consult factory; All other outputs provide constant current limiting.
CONTROL PIN SPECIFICATIONS
VI-200 E-Grade
Parameter
Min
Typ
VI-200 C-, I-, M-Grade
Max
Min
Typ
Max
Units
Gate out impedance
50
50
Ohms
Gate in impedance
1000
1000
Ohms
6
6
Volts
Gate in open circuit voltage
Gate in low threshold
0.65
Gate in low current
Power sharing accuracy
0.65
6
0.95
1.05
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Use open collector
Volts
6
0.95
Test Conditions
mA
1.05
VI-200 DC-DC Converters 50 to 200 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.9
Page 2 of 5
CONVERTER SPECIFICATIONS (cont.)
DIELECTRIC WITHSTAND CHARACTERISTICS
VI-200 E-Grade
Parameter
Input to output
Output to baseplate
Input to baseplate
Min
VI-200 C-, I-, M-Grade
Typ
Max
Min
Typ
Max
Units
Test Conditions
Baseplate earthed
3,000
3,000
VRMS
500
500
VRMS
1,500
1,500
VRMS
THERMAL CHARACTERISTICS
VI-200 E-Grade
Parameter
Min
Efficiency
Baseplate to sink
thermal impedance
Thermal shutdown[d]
(Drivers only)
[d]
VI-200 C-, I-, M-Grade
Typ
Max
Min
Typ
78 – 88%
80 – 90%
0.07
0.07
90
95
105
90
Max
Units
°C/Watt
95
105
°C
Test Conditions
With Vicor P/N 20266
Cool and recycle power
to restart
No overtemp protection in booster modules.
MECHANICAL SPECIFICATIONS
VI-200 E-, C-Grade
Parameter
Weight
VI-200 I-, M-Grade
Min
Typ
Max
Min
Typ
Max
Units
5.7
(160.2)
6.3
(178)
6.9
(195.8)
6.6
(187.2)
7.3
(208)
8.1
(228.8)
Ounces
(Grams)
Test Conditions
PRODUCT GRADE TEMPERATURES
Parameter
Storage
Operating
Units
E
-20 to +100
-10 to + 85
°C
C
-40 to +100
-25 to + 85
°C
I
-55 to +100
-40 to + 85
°C
M
-65 to +100
-55 to + 85
°C
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Set your site on VICOR at vicorpower.com
Notes
Overtemperature shutdown
95°C typical (recycle power
to restart)
Rev. 2.9
Page 3 of 5
MECHANICAL DRAWING
PACKAGING OPTIONS
SlimMod
FinMod
MegaMod
Flangeless package
Flangeless package with integral heat sink
Chassis mount alternatives, one, two,
or three outputs: up to 600 W
Longitudinal, 0.25" fins — add suffix “– F1”
Longitudinal, 0.50" fins — add suffix “– F2”
4.60"L x 1.80"W x 0.50"H
(116,8 x 45,7 x 12,7 mm)
1 up – 4.9¨ x 2.5¨ x 0.62¨ (124,4 x 63,5 x 15,7 mm)
2 up – 4.9¨ x 4.9¨ x 0.62¨ (124,4 x 124,4 x 15,7 mm)
3 up – 4.9¨ x 7.3¨ x 0.62¨ (124,4 x 185,4 x 15,7 mm)
BusMod
To order the SlimMod configuration add the suffix “ – S” to
the standard module part number.
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Transverse, 0.25" fins — add suffix “– F3”
Transverse, 0.50" fins — add suffix “– F4”
Available with longitudinal or transverse fins of 0.25" or
0.50" height. Add the appropriate suffix to the module
part number.
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
4.60"L x 2.40"W x 1.08"H
(116,8 x 61,0 x 27,4 mm)
To order the BusMod fully assembled, add suffix “–B1”
to the standard module part number.
To order the BusMod separately:
Full-sized BusMod — P/N 06322
VI-200 DC-DC Converters 50 to 200 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.9
Page 4 of 5
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance.
Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the
factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor
against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon
request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.9
8/09