VICOR VI

Data Sheet
VI-J00, VE-J00
Half Brick
DC-DC Converters
25 to 100 Watts
Features
•
•
•
•
•
•
•
•
•
•
•
•
RoHS compliant (VE versions)
Up to 50 Watts per cubic inch
cULus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
Isolated output
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC converters.
This “junior” size complement to the higher power VI-200 family offers up to 100 W of isolated
and regulated power in a board mounted package. With thousands of input/output/power
combinations, and with a maximum operating temperature rating of 100˚C, the MiniMod
provides nearly unlimited flexibiliy for power system designers to meet demanding time to
market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven by an installed
base of over 8 million units, the MiniMod family combines state of the art power density with
the efficiency, low noise and reliability required by next generation power systems.
Part Numbering
VI
Family
Series
VI = Non-RoHS
J = J00
VE = RoHS
Note: For additional
packaging options,
please see page 4.
—
J
6
Input
1
—
C
W
Output
Grade
Power
0 = 12 V N = 48 V
Z = 2V
M = 10 V
K = 40 V
E = –10 to 100°C
≥ 5V
<5
V = 24 V
4 = 72 V
Y = 3.3 V
1 = 12 V
4 = 48 V
C = –25 to 100°C
W = 100 W
W = 20 A
1 = 24 V
T = 110 V
0 = 5V
P = 13.8 V
H = 52 V
I = – 40 to 100°C
X = 75 W
X = 15 A
W = 24 V
5 = 150 V
X = 5.2 V
2 = 15 V
F = 72 V
M = –55 to 100°C
Y = 50 W
Y = 10 A
2 = 36 V
6 = 300 V
W = 5.5 V
N = 18.5 V
D = 85 V
Z = 25 W
Z=5A
3 = 48 V
7 = 150/300 V
V = 5.8 V
3 = 24 V
B = 95 V
T = 6.5 V
L = 28 V
R = 7.5 V
J = 36 V
Maximum Power Available for VI-Jxx-xx
Output
Input
Voltage
Nom. (Range)
Low Line
75%
Max Power
12 (10-20)
n/a
22
0
Vin
Transient[a] Designators 2
Z
X
3.3
Y
5
0
X
Y
Vout Designators
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28
X W V T
R M 1
P
2 N
3 L
Y
Y
Y
Y
Y
X
X
X
X
X
X
X
36 40
J K
48
4
52
H
72 85
F D
95
B
X
X
X
X
X
X
X
24 (10-36)
n/a
n/a
V
--
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
--
--
--
--
24 (21-32)
18
36
1
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
24 (18-36)
n/a
n/a
W
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
36 (21-56)
18
60
2
Y
Y
Y
Y
Y
Y
Y
Y
X
X
X
X
X
X
X
X
X
X
X
--
--
-W
48 (42-60)
36
72
3
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
48 (36-76)
n/a
n/a
N
W
W
X
X
X
X
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
72 (55-100)
45
110
4
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
110 (66-160)
n/a
n/a
T
W
W
X
X
X
X
X
X
W
W
W
W
W
W
W
W
W
W
W
W
--
--
150 (100-200)
85
215
5
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
150 (100-375)
90
n/a
7
Y
Y
Y
Y
Y
Y
Y
Y
X
X
X
X
X
X
X
X
X
X
X
--
--
--
300 (200-400)
170
425
6
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
[a]
Transient voltage for 1 second.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-J00 MiniMod DC-DC Converters 25 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.3
Page 1 of 5
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
VI-J00 E-Grade
Parameter
Min
Typ
Inrush charge
60x 10
Input reflected
ripple current – pp
VI-J00 C-, I-, M-Grade
Max
Min
Typ
-6
60x 10
10%
100 x 10
( )
20+ 20 Log ( Vin )
( )
30+ 20 Log Vin
Vout
Vout
Vout
No load power dissipation
1.35
2
Units
-6
10%
25+ 20 Log Vin
Input ripple rejection
Max
-6
1.35
Coulombs
Test Conditions
Nominal line
IIN
Nominal line, full load
dB
120 Hz, nominal line
dB
2400 Hz, nominal line
2
Watts
Typ
Max
Units
OUTPUT CHARACTERISTICS
VI-J00 E-Grade
Parameter
Min
Setpoint accuracy
VI-J00 C-, I-, M-Grade
Typ
Max
1%
2%
0.5%
1%
VNOM
0.5%
0.05%
0.2%
VNOM
LL to HL, 10% to Full Load
1%
0.2%
0.5%
VNOM
LL to HL, No Load to 10%
0.02
% / °C
Load/line regulation
Min
Output temperature drift
0.02
0.01
Long term drift
0.02
0.02
Output ripple – pp:
2 V, 3.3 V
5V
10 – 95 V
[a]
Trim range
50%
Total remote
sense compensation
0.5
Test Conditions
Over rated temperature
%/1K hours
200
100
150
mV
20 MHz bandwidth
5%
2%
3%
VNOM
20 MHz bandwidth
3%
0.75%
1.5%
VNOM
20 MHz bandwidth
110%
VNOM
110%
50%
0.5
Volts
0.25 V max. neg. leg
Automatic restart
Current limit
105%
135%
105%
125%
INOM
Short circuit current
105%
140%
105%
130%
INOM
[a] 10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
95 V output –50 + 0% trim range.
CONTROL PIN SPECIFICATIONS
VI-J00 E-Grade
Parameter
Min
Typ
VI-J00 C-, I-, M-Grade
Max
Min
Typ
Max
Units
Gate out impedance
50
50
Ohms
Gate in impedance
1000
1000
Ohms
Gate in high threshold
Gate in low threshold
Gate in low current
6
6
0.65
0.65
6
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Volts
Test Conditions
Use open collector
Volts
6
mA
VI-J00 MiniMod DC-DC Converters 25 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.3
Page 2 of 5
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
DIELECTRIC WITHSTAND CHARACTERISTICS
VI-J00 E-Grade
Parameter
Input to output
Output to baseplate
Input to baseplate
Min
Typ
VI-J00 C-, I-, M-Grade
Max
Min
Typ
Max
Units
Test Conditions
Baseplate earthed
3,000
3,000
VRMS
500
500
VRMS
1,500
1,500
VRMS
THERMAL CHARACTERISTICS
VI-J00 E-Grade
Parameter
Min
Typ
Efficiency
VI-J00 C-, I-, M-Grade
Max
Min
Typ
78 – 88%
80 – 90%
0.14
0.14
Baseplate to sink
Max
Units
°C/Watt
Test Conditions
With Vicor P/N 20267
MECHANICAL SPECIFICATIONS
VI-J00 E-Grade
VI-J00 C-, I-, M-Grade
Parameter
Min
Typ
Max
Min
Typ
Max
Units
Weight
2.9
82.8
3.2
92
3.6
101.2
3.4
96.3
3.8
107
4.1
117.7
Ounces
Grams
Test Conditions
PRODUCT GRADE TEMPERATURES
Parameter
Storage
Operating
Units
E
-20 to +105
-10 to + 100
°C
C
-40 to +105
-25 to + 100
°C
I
-55 to +105
-40 to + 100
°C
M
-65 to +105
-55 to + 100
°C
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-J00 MiniMod DC-DC Converters 25 to 100 Watts
Set your site on VICOR at vicorpower.com
Notes
Rev. 2.3
Page 3 of 5
MECHANICAL DRAWING
.49
(12,4)
.30±.015
(7,6)±(0,38)
2.28
(57,9)
1.30
(33,0)
.65
(16,5)
Standard
RoHS
0.080 Dia (2) places
Solder plate
over copper alloy
0.080 Dia (2) places
Matte tin over copper
alloy
Pin #
Function
+In
1
4
9
3
8
VI-J00
2.10
(53,4)
2
6
1
.15
(3,8)
7
5
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35± .015
(8,9)±(0,38)
Standard
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
FULL R
.15
(3,8)
2
Gate In
3
Gate Out
4
-In
5
+Out
6
+Sense
7
Trim
8
–Sense
9
–Out
RoHS
0.040 Dia (7) places
Matte tin over copper
alloy
2.40
(61,0)
Product ID
this surface
1.90
(48,3)
.30
(7,6) Min.
.22
(5,6) Min.
.50
(12,7)
1.75
(44,4) Max.
+.030 (0,76)
-.000 (0)
.01
.12
(3,0)
Aluminum Base
PACKAGING OPTIONS
Flangeless package
Flangeless package
with integral heat sink
Longitudinal, 0.25" fins — add suffix “– F1”
Longitudinal, 0.50" fins — add suffix “– F2”
2.28"L x 1.80"W x 0.50"H
(57,9 x 45,7 x 12,7 mm)
MegaMod Jr.
Chassis mount alternatives, one, two,
or three outputs: up to 300 W
1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7 mm)
2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7 mm)
3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7 mm)
To order the SlimMod configuration add the suffix “ – S” to
the standard module part number.
BusMod
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Transverse, 0.25" fins — add suffix “– F3”
Transverse, 0.50" fins — add suffix “– F4”
Available with longitudinal or transverse fins of 0.25" or
0.50" height. Add the appropriate suffix to the module
part number.
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
2.28"L x 2.40"W x 1.08"H
(57,9 x 61,0 x 27,4 mm)
To order the BusMod fully assembled, add suffix “–B1” to
the standard module part number.
To order the BusMod separately:
Half-sized BusMod — P/N 18952
VI-J00 MiniMod DC-DC Converters 25 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.3
Page 4 of 5
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor
against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC
modules and accessory components, fully configurable AC-DC and DC-DC power supplies,
and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-J00 MiniMod DC-DC Converters 25 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 2.3
8/09