OMRON EY3A-110-A

Single Beam Sensor (1 Beam: 100 mm)
EY3A-110-A
■ Dimensions
■ Features
Note: All units are in millimeters unless otherwise indicated.
• Ensures higher sensitivity and external light interference resistivity
than any other photomicrosensor.
• Narrow sensing range ensures stable sensing of a variety of sensing objects.
Center of
positioning boss
Center of detector
R5
3.05 +0.05
0 dia.
10
4 −0.2 dia.
1
15
12.3
3.3
C
2.7
1
30±0.1
17
Pin no. Remarks
Load voltage
VOUT
7V
Load current
IOUT
10 mA
Operating
Topr
0° C to 60° C
Storage
Tstg
–15° C to 70° C
Note: Make sure there is no icing or condensation when operating the
Sensor.
dia.
Description
Model
Single beam sensor
Name
1
O
Output (OUT)
2
3
V
G
Power supply (Vcc)
Ground (GND)
Rated value
7V
■ Ordering Information
58
64.4
3.2
Symbol
VCC
Ambient
temperature
Pin No. 1
0
−0.2
Item
Power supply voltage
0
Center of emitter
3.6
dia
.
■ Absolute Maximum Ratings (Ta = 25° C)
20±0.1
8.3
ia.
5d
6±0.1
32
19.2
R2
7
41.6±0.1
2.7±0.1
2-
EY3A-110-A
Unless otherwise specified, the
tolerances are as shown below.
Dimensions
3 mm max.
Tolerance
±0.3
3 < mm ≤ 6
±0.375
6 < mm ≤ 10
±0.45
10 < mm ≤ 18
±0.55
18 < mm ≤ 30
±0.65
30 < mm ≤ 50
±0.8
50 < mm ≤ 80
±0.95
Recommended Mating Connectors:
Tyco Electronics AMP 173977-3 (press-fit connector)
179228-3 (crimp connector)
175778-3 (crimp connector)
■ Electrical and Optical Characteristics (Ta = 0° C to 60° C)
Item
Value
Condition
Power supply voltage
5 V ±5%
---
Current consumption
50 mA max.
V CC = 5 V, RL = ∞
Peak current consumption
200 mA max.
VCC = 5 V, RL = ∞
Low-level output voltage
0.6 V max.
VCC = 5 V, IOL = 4 mA (see note 1)
High-level output voltage
3.5 V min.
VCC = 5 V, RL = 4.7 kΩ (see note 2)
Response delay time (high to low)
1.5 ms max.
The time required for the output to become “Lo” after placing
sensing object.
Response delay time (low to high)
1.5 ms max.
The time required for the output to become “Hi” after removing
sensing object.
Note: 1. These conditions are for the sensing of lusterless paper with an OD of 0.9 maximum located at the correct sensing position of the Sensor
as shown in the optical path arrangement on the next page.
2. These conditions are for the sensing of the paper supporting plate with an OD of 0.05 located using the glass plate without paper as
shown in the optical path arrangement on the next page.
134
Single Beam Sensor (1 Beam: 100 mm) EY3A-110-A
■ Characteristics (Paper Table Glass: t = 6 mm max., Transparency Rate: 90% min.)
(Ta =0° C to 60° C)
Item
Characteristic value
Sensing density
Lusterless paper with an OD of 0.42 max. (sensing distance: 50 mm) (see note)
Non-sensing distance
150 mm (from the top of the sensor), OD: 0.05
Paper sensing distance
100 mm (from the top of the sensor)
Ambient illumination
Sunlight: 3,000 lx max., fluorescent light: 2,000 lx max.
Note: 1. The data shown are initial data.
2. Optical darkness (OD) is defined by the following formula:
OD = − log10
PIN (mW):
POUT
PIN
Light power incident upon the document
POUT (mW): Reflected light power from the document
■ Optical Path Arrangement
150 (see note 2)
14
100 (standard value)
10 dia. (see note 1)
8.9
Paper supporting plate
Glass
Note: 1. The part with oblique lines indicates the paper sensing area of the EY3A-110-A, which is practically determined by the diameter of the
beam and its tolerance.
2. The non-sensing distance of the EY3A-110-A is determined using a paper with an OD of 0.05.
■ Engineering Data
EY3A-110-A Distance Characteristics (Typical)
1.4
4.75 V
5.0 V
5.25 V
1.2
OD (value)
1
0.8
0.6
0.4
0.2
80
85
90
95
100
105
110
115
120
125
130
Distance (mm)
Single Beam Sensor (1 Beam: 100 mm) EY3A-110-A
135