OPEN FRAME & ENCLOSED TAC A C F I LT E R Features • • • • Ultra high attenuation type of common mode noise from 150kHz to 1MHz. Three Phase 500Vac. Quick and easy push down terminal. Din rail installation type (Option). Specification Ordering Information INPUT Voltage 500Vac, 3 phase Test voltage (Terminal-mounting plate) 2kVac (cutoff current = 100mA), 1 minute at room temperature and humidity. Isolation resistance (Terminal-mounting plate) 500Vdc, 100MW minute at room temperature and humidity. OUTPUT Current See table. Leakage current 2.5mA/5.0mA max (125/250Vac, 60Hz) Voltage drop 1.5V max (TAC-04, TAC-06) 1.0V max (TAC-10, TAC-20, TAC-30) TAC -10 -683 (1) (2) (3) CODE -25°C to 85°C (Refer to derating curve). Temperature Operating temperature -40°C to 85°C (Refer to derating curve). Storage temperature -40°C to 85°C Humidity 20% to 95% RH (Non-condensing) Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1 hour each X, Y and Z axis. Impact 196.1m/s2 (20G), 11ms once each X, Y and Z axis. (4) 1. Model name 2. Rated current 3. Line to ground capacitor code 4. Options D: Din rail installation type. ENVIRONMENTAL Safety agency approval _ CURRENT 06 6A 10 10A 16 16A 20 20A 30 30A CODE LEAKAGE CURRENT(INPUT 125/250V 60HZ) LINE TO GROUND CAPACITOR(NOMINAL VALUE) 683 2.5mA / 5.0mA max 68000pF STANDARDS Safety UL1283, CSA C 22.2 No. 8 (C-UL), DIN EN133200 VDE0565 Teil3-1, ENEC. Your dependable power partner – www.powerbox.com.au 145