POWERBOX NAC-10-472

OPEN FRAME & ENCLOSED
NAC
A C F I LT E R
Features
•
•
•
•
•
High-attenuation type of common mode noise
from 150kHz to 1MHz.
Single Phase 250Vac.
Selectable leakage current.
Quick and easy push down terminal.
Din rail installation type (Option).
Specifications
Ordering Information
INPUT
Voltage
250Vac/250Vdc, 1 phase
Test voltage
(Terminal-mounting plate)
2.5kVac (cutoff current = 20mA), 1 minute at
room temperature and humidity.
Isolation resistance
(Terminal-mounting plate)
500Vdc, 100MW minute at room temperature and
humidity.
OUTPUT
Current
See table.
Leakage current
0.5mA/1.0mA (125/250Vac, 60Hz)
Voltage drop
NAC
-10
-472
(1)
(2)
(3)
CODE
ENVIRONMENTAL
-25°C to 85°C (Refer to derating curve).
Operating temperature
-40°C to 85°C (Refer to derating curve).
Storage temperature
-40°C to 85°C
Humidity
20% to 95% RH (Non-condensing)
Vibration
10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1 hour
each X, Y and Z axis.
Impact
196.1m/s2 (20G), 11ms once each X, Y and Z axis.
STANDARDS
Safety
UL1283, CSA C 22.2 No. 8 (C-UL), DIN EN133200
VDE0565 Teil3-1, ENEC (At only AC input).
C-tick
AS/NZS CISPR11 Group 1, Class A
(4)
1. Model name
2 Rated current
3. Line to ground capacitor code
4. Options
D: Din rail installation type.
1.0V max
Safety agency approval
Temperature
_
CURRENT
06
6A
10
10A
16
16A
20
20A
30
30A
CODE
LEAKAGE
CURRENT(INPUT
125/250V 60HZ)
LINE TO GROUND
CAPACITOR(NOMINAL
VALUE)
681
75.5mA / 150mA max
680pF
102
0.13mA / 0.25mA max
1000pF
222
0.25mA / 0.5mA max
2200pF
332
0.38mA / 0.75mA max
3300pF
472
0.5mA / 1.0mA max
4700pF
When the line to ground capacitor code is different, the attenuation
characteristic is different.
Your dependable power partner – www.powerbox.com.au