VECTRON TFS110R

file: tfs110r.doc
version 1.2
VI TELEFILTER
Filter specification
30.11.00
TFS 110R
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
23°C
0 dBm
2,9 kΩ || -6.2 pF
2,8 kΩ || -5.5 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 110 R is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 30 dB filter attenuation level relative to the insertion loss ae.
Data
typ. value
Insertion loss
(reference level)
ae = amin
Reference frequency
fc (30 dB-BW)
8
dB
bandwidth
bandwidth
bandwidth
bandwidth
bandwidth
10
± 60
Gaussian
965
1695
2255
2600
2840
BW
arel
Relative attenuation
fc + 475
kHz
fc - 425
kHz
fc ± 800
kHz
fc + 1200
kHz
fc - 1210
kHz
fc + 1375
kHz
fc - 1395
kHz
fc + 1500
kHz ... fc + 5
MHz
fc +
5
MHz ... fc +10
MHz
fc - 1535
kHz ... fc - 10
MHz
Group delay
Ripple fc ± 576 kHz
max.
110,0 MHz
Pass band shape (3 dB-BW)
3 dB
10 dB
20 dB
30 dB
40 dB
tolerance / limit
> 40
> 40
> 45
kHz
kHz
kHz
kHz
kHz
dB
dB
dB
dB
kHz
-
-
max.
max.
min.
min.
min.
min.
min.
min.
min.
min.
3
3
10
20
20
30
30
35
30
40
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
max. 400
ns
GD
Temperature coefficient
250
TC 2nd order *)
Frequency inversion temperature To
- 0,032 ppm/K²
-
t.b.d.
Operating temperature range
Storage temperature range
Input power level
ns
- 10 °C ... + 60 °C
- 40 °C ... + 85 °C
-
max. + 10
dBm
*) - ∆f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz)
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110r.doc
version 1.2
VI TELEFILTER
Filter specification
30.11.00
TFS 110R
2/5
Construction and pin connection
(All dimensions in mm)
S 110 R
M47
1
2
3
4
5
6
7
8
9
10
11
12
Datecode
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input RF Return
Input
Ground
Ground
Datecode:
K
L
M
N
...
Year+week
1998
1999
2000
2001
50 Ω test circuit
L1
L2
10
Input
4
Input
SAW
50 Ohm
C1
50 Ohm
C2
1,2,3,5,6,7,
8,9,11,12
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110r.doc
version 1.2
VI TELEFILTER
Filter specification
TFS 110R
30.11.00
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing:
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
4
1,5
E
F
:
:
1,75 ± 0,1
7,5 ± 0,1
G (min) :
P2
:
P1
:
0,6
2 ± 0,1
8 ± 0,1
3000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
+ 0,5
Do
Po
P2
E
Ao
F
D1
W
Bo
Ct
G
D1(min) :
Ao
:
1,5
5,5
± 0,1
Bo
:
7,5
± 0,1
Ct
:
13,5+/-0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
50
C
C
:
13
-
+ 0,5
A
N
0,2
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the
sprocket holes.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110r.doc
version 1.2
VI TELEFILTER
Filter specification
TFS 110R
30.11.00
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110r.doc
VI TELEFILTER
version 1.2
Filter specification
30.11.00
TFS 110R
5/5
History
Version
Reason of Changes
Name
Date
1.2.
- tape and reel dimensions corrected
Steiner
30.11.00
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.